FOUNDRY-SN-SWITCH-GROUP-MIB
- Registered at
- 1.3.6.1.4.1.1991.1.1.3
- Last updated
- 2010-06-02 00:00
- Organization
- Brocade Communications Systems, Inc.
- Revisions
- 2010-06-02 00:00, 2009-09-30 00:00
- Namespace
- extreme
- Source file
FOUNDRY-SN-SWITCH-GROUP-MIB- Digest
sha256:9c574c9588816a61e8e879f368743aebbc2c39ad797058aa6df5d70b7d10a3ac
Description
Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
Contact
Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com
Imports
| From | Symbols |
|---|---|
| FOUNDRY-SN-AGENT-MIB | DisplayString, MacAddress |
| FOUNDRY-SN-ROOT-MIB | switch |
| IF-MIB | InterfaceIndex, InterfaceIndexOrZero, ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
11 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
FOUNDRY-SN-AGENT-MIB FOUNDRY-SN-ROOT-MIB FOUNDRY-SN-SWITCH-GROUP-MIB HCNUM-TC IANAifType-MIB IF-MIB INET-ADDRESS-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1991.1.1.3.16 | snCAR | FOUNDRY-CAR-MIB |
| 1.3.6.1.4.1.1991.1.1.3.17 | snVLanCAR | FOUNDRY-VLAN-CAR-MIB |
| 1.3.6.1.4.1.1991.1.1.3.21 | snVsrp | FOUNDRY-SN-VSRP-MIB |
| 1.3.6.1.4.1.1991.1.1.3.22 | snArpInfo | FOUNDRY-SN-ARP-GROUP-MIB |
| 1.3.6.1.4.1.1991.1.1.3.23 | snWireless | FOUNDRY-SN-WIRELESS-GROUP-MIB |
| 1.3.6.1.4.1.1991.1.1.3.28 | snMacAuth | FOUNDRY-SN-MAC-AUTHENTICATION-MIB |
| 1.3.6.1.4.1.1991.1.1.3.29 | snMetroRing | FOUNDRY-SN-MRP-MIB |
| 1.3.6.1.4.1.1991.1.1.3.30 | snMacVlan | FOUNDRY-SN-MAC-VLAN-MIB |
| 1.3.6.1.4.1.1991.1.1.3.31 | snStacking | FOUNDRY-SN-STACKING-MIB |
| 1.3.6.1.4.1.1991.1.1.3.32 | fdryMacVlanMIB | FOUNDRY-MAC-VLAN-MIB |
| 1.3.6.1.4.1.1991.1.1.3.33 | fdryLinkAggregationGroupMIB | FOUNDRY-LAG-MIB |
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| BrcdVlanIdTC TEXTUAL-CONVENTION The VLAN-ID that uniquely identifies a specific VLAN. | current | |||
| BridgeId TEXTUAL-CONVENTION the Bridge-Identifier as used in the Spanning Tree | current | |||
| FdryVlanIdOrNoneTC TEXTUAL-CONVENTION The VLAN-ID that uniquely identifies a specific VLAN, or no VLAN. The special value of zero is used to indicate that no VLAN-ID is present or used. This can be used in any situation where an object or a table entry must refer either to a specific VLAN, or to no VLAN. Note that a MIB object that is defined using this TEXTUAL-CONVENTION should clarify the meaning of 'no VLAN' (i.e., the special value 0). | current | |||
| InterfaceId TEXTUAL-CONVENTION -- This data type is used to specify an interface ID. -- The first object identifier is port type, and the -- format of the rest of the object identifiers depend -- on the port type. -- -- ethernet(1), format: type.slot.port -- e.g. 1.3.6 is port ethernet 3/6 -- -- pos(2), format: type.slot.port -- e.g. 2.10.1 is port pos 10/1 -- -- atm(3), format: type.slot.port -- e.g. 3.8.2 is port atm 8/2 -- -- virtual router interface(4), format: type.ve -- e.g. 4.9 is port ve 9 -- -- loopback(5), format: type.lb -- e.g. 5.7 is port loopback 7 -- -- gre tunnel(6), format: type.tn, not supported -- -- subinterface(7), format: type.slot.port.subInterface -- e.g. 7.3.2.4 is port atm 3/2.4 -- -- mpls tunnel(8), format: type.tn -- e.g. 8.3 is port tunnel 3 -- -- pvc(9), format: type.slot.port.subInterface.vpi.vci -- e.g. 9.3.1.2.1.2 is port atm 3/1.2.1.2 -- -- management(10), format: type.slot.port -- e.g. 10.17.1 is port management 17/1 -- -- tunnel(11), format: type.trunkid -- e.g. 11.3 is trunk id 3 -- -- virtual management(12), format: type -- e.g. 10 is the virtual management interface | current | |||
| InterfaceId2 TEXTUAL-CONVENTION -- This data type is used to specify an interface ID. The -- first object identifier is port type, and the format of -- the rest of the object identifiers depend on the port -- type. Note that for types which include a reference to a -- physical port, the formats vary according to the type of -- port identifiers that the device uses (e.g. 6, 3/6, or -- 2/3/6). New port type values will be added in the future -- as needed. For a given type code, new formats may also -- be added in the future. Each format for a given type -- code will have a unique length. Applications should -- check the OID length and not assume that it will match -- one of the currently defined formats. -- -- Though the OIDs are shown here in a shortened form, the -- actual OIDs are prefixed with the OID of snInterfaceId -- (so the OID for 1.2.3.6 would actually be -- snInterfaceId.1.2.3.6, which is equivalent to -- snEthernetInterface.2.3.6.). -- -- ethernet(1), formats: -- type.port (e.g. 1.6 is port ethernet 6) -- type.slot.port (e.g. 1.3.6 is port ethernet 3/6) -- type.unit.slot.port (e.g. 1.2.3.6 is port ethernet 2/3/6) -- -- pos(2), formats: -- type.port (e.g. 2.6 is port pos 6) -- type.slot.port (e.g. 2.3.6 is port pos 3/6) -- type.unit.slot.port (e.g. 2.2.3.6 is port pos 2/3/6) -- -- atm(3), format: type.slot.port -- type.port (e.g. 3.6 is port atm 6) -- type.slot.port (e.g. 3.3.6 is port atm 3/6) -- type.unit.slot.port (e.g. 3.2.3.6 is port atm 2/3/6) -- -- virtual router interface(4), format: type.ve -- e.g. 4.9 is port ve 9 -- -- loopback(5), format: type.lb -- e.g. 5.7 is port loopback 7 -- -- gre tunnel(6), format: type.tn, not supported -- -- subinterface(7), formats: -- type.port.subInterface (e.g. 7.6.4 is port atm 6.4) -- type.slot.port.subInterface (e.g. 7.3.6.4 is port atm 3/6.4) -- type.unit.slot.port.subInterface -- (e.g. 7.2.3.6.4 is port atm 2/3/6.4) -- -- mpls tunnel(8), format: type.tn -- e.g. 8.3 is port tunnel 3 -- -- pvc(9), formats: -- type.port.subInterface.vpi.vci -- (e.g. 9.6.2.1.2 is port atm 6.2.1.2) -- type.slot.port.subInterface.vpi.vci -- (e.g. 9.3.6.2.1.2 is port atm 3/6.2.1.2) -- type.unit.slot.port.subInterface.vpi.vci -- (e.g. 9.2.3.6.2.1.2 is port atm 2/3/6.2.1.2) -- -- management(10), formats: -- type.port (e.g. 10.1 is port management 1) -- type.slot.port (e.g. 10.2.1 is port management 2/1) -- type.unit.slot.port (e.g. 10.4.2.1 is port management 4/2/1) -- -- trunk(11), format: type.trunkid -- e.g. 11.3 is trunk id 3 -- -- virtual management(12), format: type -- e.g. 12 is the virtual management interface | current | |||
| PhysAddress TEXTUAL-CONVENTION This data type is used to model media addresses. For many types of media, this will be in a binary representation. For example, an ethernet address would be represented as a string of 6 octets. | current | |||
| PortMask TEXTUAL-CONVENTION This data type is used to model port bitmask. The maximum of ports are 32. | current | |||
| PortPriorityTC TEXTUAL-CONVENTION Refers to the IEEE 802.1p priority, or Priority Code Point (PCP). 1 is the lowest, 8 is the highest. The value 128 may be used to indicate invalid priority or priority is not enabled. | current | |||
| PortQosTC TEXTUAL-CONVENTION The port QOS Priority hardware queue. 0 is lowest priority, 7 is the highest. | current | |||
| Timeout TEXTUAL-CONVENTION a STP timer in units of 1/100 seconds | current | |||
| VlanTagMode TEXTUAL-CONVENTION Vlan tag mode for a given vlan member. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| snSwInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.1 | |||
| snSwGroupOperMode OBJECT-TYPE noVLan(1) represents all switch ports with no virtual LAN by port (no Port VLAN), and with no tag assigned. vlanByPort(2) represents all switch ports with Basic VLAN (layer2 Switch). | 1.3.6.1.4.1.1991.1.1.3.1.1 | INTEGER {noVLan(1), vlanByPort(2)} | read-write | current |
| snSwGroupIpL3SwMode OBJECT-TYPE The Switch Group is configured with the Layer3 IP Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 IP Switch disabled(0)..........disable Layer3 IP Switch | 1.3.6.1.4.1.1991.1.1.3.1.2 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwGroupIpMcastMode OBJECT-TYPE The Switch Group is configured with the IP Multicast pruning mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IP Multicast pruning disabled(0)..........no IP Multicast pruning | 1.3.6.1.4.1.1991.1.1.3.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwGroupDefaultCfgMode OBJECT-TYPE The Switch Group is configured with the Default configuration. If the default configuration gets overwritten, the state will change to non-default. default(1)...........default configuration nonDefault(2)..........non default configuration | 1.3.6.1.4.1.1991.1.1.3.1.4 | INTEGER {default(1), nonDefault(2)} | read-write | current |
| snSwGroupSwitchAgeTime OBJECT-TYPE The Switch Age time is 180sec by default. The configured range is 10 to 10,000sec. The time represents the time span to age out an MAC Address entry. | 1.3.6.1.4.1.1991.1.1.3.1.5 | Integer32 | read-write | current |
| snVLanGroupVlanCurEntry OBJECT-TYPE The current total entry number of VLANs are configured. | 1.3.6.1.4.1.1991.1.1.3.1.6 | Integer32 | read-only | current |
| snVLanGroupSetAllVLan OBJECT-TYPE The value of this object is the VLanIndex of a particalur entry in snVLanByPortCfgTable (snVLanByPortCfgVLanId). All the attributes of that row of table except PortMask will be used to set the same attributes for the entire VLan group. VLanId and PortMask must be set for that particular entry prior to setting this object. Switch software will base on that VLAN information to set the entire VLAN. Note: All the intended attributes of the given row of the table (given VLAN) must be set prior setting this object. When this object is set, Set-All-VLAN action will take place simultaneously. The previous setting will be overwritten by the new one. | 1.3.6.1.4.1.1991.1.1.3.1.7 | Integer32 | read-write | current |
| snSwPortSetAll OBJECT-TYPE The value of this object is the index number of the snSwPortInfoTable (snSwPortInfoPortIndex). snSwPortInfoMonitorMode, snSwPortInfoTagMode, snSwPortInfoChnMode, snSwPortInfoSpeed, snSwPortInfoAdminStatus are all the read-write attributes of that row of table. They will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one. | 1.3.6.1.4.1.1991.1.1.3.1.8 | Integer32 | read-write | current |
| snFdbTableCurEntry OBJECT-TYPE The current total entry number of FDB are configured. | 1.3.6.1.4.1.1991.1.1.3.1.9 | Integer32 | read-only | current |
| snFdbTableStationFlush OBJECT-TYPE The following values of the flush state can only be read: normal(1)... normal state error(2)... operation failed flushing(4)... in process The following value can be written: flush(3).....do flush The agent will return a response even before the flush is done. And the read value will be flushing until flush is done. And the flush request will be rejected until error or normal. | 1.3.6.1.4.1.1991.1.1.3.1.10 | INTEGER {normal(1), error(2), flush(3), flushing(4)} | read-write | current |
| snPortStpSetAll OBJECT-TYPE The value of this object is 1 which means invoking Port STP Set-all command. The snPortStpPriority, snPortStpPathCost, the read-write STP related attributes of the first row of table will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one. | 1.3.6.1.4.1.1991.1.1.3.1.11 | Integer32 | read-write | current |
| snSwProbePortNum OBJECT-TYPE A chassis switch probe port is operated as a traffic analyzer port and only one port can be assigned in the chassis. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. A stackable switch is only assigned with one probe port as a traffic analyzer. | 1.3.6.1.4.1.1991.1.1.3.1.12 | Integer32 | read-write | current |
| snSw8021qTagMode OBJECT-TYPE The Switch Group is configured with the IEEE802.1q Tagging mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IEEE802.1q Tagging mode. disabled(0)..........no IEEE802.1q Tagging. | 1.3.6.1.4.1.1991.1.1.3.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwGlobalStpMode OBJECT-TYPE Spanning Tree System Global Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree | 1.3.6.1.4.1.1991.1.1.3.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIpMcastQuerierMode OBJECT-TYPE The IP Multicast pruning mode is configured either Non-Querier or Querier mode and the default is querier mode. querier(1)...........when prunning traffic locally within the VLAN. nonQuerier(2)........when running with a multicast capable router in the network. | 1.3.6.1.4.1.1991.1.1.3.1.15 | INTEGER {querier(1), nonQuerier(2)} | read-write | current |
| snSwViolatorPortNumber OBJECT-TYPE The port number of the switch or router that received a violator packet. It is included in the locked address violation trap. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only). | 1.3.6.1.4.1.1991.1.1.3.1.17 | Integer32 | read-only | current |
| snSwViolatorMacAddress OBJECT-TYPE The source address of the violator packet received by the switch or router. It is included in the locked address violation trap. | 1.3.6.1.4.1.1991.1.1.3.1.18 | MacAddress | read-only | current |
| snVLanGroupVlanMaxEntry OBJECT-TYPE The maximum number of VLAN entries that are allowed to configure. On NetIron products, This object will be implemented as read-only. Set request will be returned with not writable error. To set the maximum allowed vlan, use snAgentSysParaConfigEntry. | 1.3.6.1.4.1.1991.1.1.3.1.19 | Integer32 | read-write | current |
| snSwEosBufferSize OBJECT-TYPE A specific buffer size for all the different EOS buffers. | 1.3.6.1.4.1.1991.1.1.3.1.20 | Integer32 | read-only | current |
| snVLanByPortEntrySize OBJECT-TYPE The size of each VLAN table entry. | 1.3.6.1.4.1.1991.1.1.3.1.21 | Integer32 | read-only | current |
| snSwPortEntrySize OBJECT-TYPE The size of each port table entry. | 1.3.6.1.4.1.1991.1.1.3.1.22 | Integer32 | read-only | current |
| snFdbStationEntrySize OBJECT-TYPE The size of each Fdb station table entry. | 1.3.6.1.4.1.1991.1.1.3.1.23 | Integer32 | read-only | current |
| snPortStpEntrySize OBJECT-TYPE The size of each port stp table entry. | 1.3.6.1.4.1.1991.1.1.3.1.24 | Integer32 | read-only | current |
| snSwEnableBridgeNewRootTrap OBJECT-TYPE Indicates whether the SNMP agent process is permitted to generate bridge new root traps. | 1.3.6.1.4.1.1991.1.1.3.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwEnableBridgeTopoChangeTrap OBJECT-TYPE Indicates whether the SNMP agent process is permitted to generate bridge topology change traps. | 1.3.6.1.4.1.1991.1.1.3.1.26 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwEnableLockedAddrViolationTrap OBJECT-TYPE Indicates whether the SNMP agent process is permitted to generate locked address violation traps. | 1.3.6.1.4.1.1991.1.1.3.1.27 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIpxL3SwMode OBJECT-TYPE The Switch Group is configured with the Layer3 IPX Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 Switch disabled(0)..........disable Layer3 Switch | 1.3.6.1.4.1.1991.1.1.3.1.28 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snVLanByIpSubnetMaxSubnets OBJECT-TYPE The maximum number of subnets for each IP VLAN. | 1.3.6.1.4.1.1991.1.1.3.1.29 | Integer32 | read-only | current |
| snVLanByIpxNetMaxNetworks OBJECT-TYPE The maximum number of networks for each IPX VLAN. | 1.3.6.1.4.1.1991.1.1.3.1.30 | Integer32 | read-only | current |
| snSwProtocolVLanMode OBJECT-TYPE disabled(0) - represents system with Protocol VLAN disabled. enabled(1) - represents system with Protocol VLAN enabled (Layer3 VLAN). | 1.3.6.1.4.1.1991.1.1.3.1.31 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snMacStationVLanId OBJECT-TYPE This VLAN ID controls filtering of the Forwarding Database table in the standard Bridge MIB (dot1dTpFdbTable). Since the dot1dTpFdbTable contains MAC addresses associated with each of the ports in the bridge, and each MAC address can be associated with different VLANs, the snMacStationVLanId can be used by users to specify which VLAN's MAC Station information the dot1dTpFdbTable should provide. If this variable is set to zero (the default value), all MAC station entries will be returned when the dot1dTpFdbTable is retrieved. The VLAN-aware dot1qTpFdbTable described in RFC 2674 should be used as a replacement for this variable. | 1.3.6.1.4.1.1991.1.1.3.1.32 | INTEGER (0..4095) | read-write | deprecated |
| snSwClearCounters OBJECT-TYPE valid(0) - a SNMP-GET of this mib shows that it is valid command to use. clear(1) - represents clear counter command of the following counters: Dot3, MIB2, IP and IPX counters for all ports. | 1.3.6.1.4.1.1991.1.1.3.1.33 | INTEGER {valid(0), clear(1)} | read-write | current |
| snSw8021qTagType OBJECT-TYPE The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value. | 1.3.6.1.4.1.1991.1.1.3.1.34 | Integer32 | read-write | current |
| snSwBroadcastLimit OBJECT-TYPE Limit the number of broadcast packets to forward out of the switch ports. This object specifies the number of broadcast packets per second. Setting a value of 0 to this object disables the limitation check. | 1.3.6.1.4.1.1991.1.1.3.1.35 | Integer32 | read-write | current |
| snSwMaxMacFilterPerSystem OBJECT-TYPE The maximum number of MAC Filters per system in the MAC Filter table. | 1.3.6.1.4.1.1991.1.1.3.1.36 | Integer32 | read-only | current |
| snSwMaxMacFilterPerPort OBJECT-TYPE The maximum number of MAC Filters per port in the Port MAC Access Filter table. | 1.3.6.1.4.1.1991.1.1.3.1.37 | Integer32 | read-only | current |
| snSwDefaultVLanId OBJECT-TYPE The VLAN ID of the DEFAULT PORT-VLAN. | 1.3.6.1.4.1.1991.1.1.3.1.38 | INTEGER (1..4095) | read-write | current |
| snSwGlobalAutoNegotiate OBJECT-TYPE This feature only applies to Gigabit Ethernet ports. If set to disable(0), all Gigabit Ethernet ports will be put to non- negotiation mode. If set to enable(1), all Gigabit Ethernet ports will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), all Gigabit Ethernet ports will start with auto-negotiation, if the negotiation failed, then they will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If the snSwPortInfoAutoNegotiate value of a port was not set to global, this global value does not apply to the negotiation mode of that port. | 1.3.6.1.4.1.1991.1.1.3.1.39 | INTEGER {disabled(0), enabled(1), negFullAuto(2), other(3)} | read-write | current |
| snSwQosMechanism OBJECT-TYPE Indicates whether the qos mechanism is strict or weighted. | 1.3.6.1.4.1.1991.1.1.3.1.40 | INTEGER {strict(0), weighted(1)} | read-write | current |
| snSwSingleStpMode OBJECT-TYPE Single Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is disabled mode. disable(0)...........no Single Spanning Tree enableStp(1).........activate SSTP control vlan to run Spanning Tree enableRstp(2)........activate SSTP control vlan to run Rapid Spanning Tree | 1.3.6.1.4.1.1991.1.1.3.1.41 | INTEGER {disable(0), enableStp(1), enableRstp(2)} | read-write | current |
| snSwFastStpMode OBJECT-TYPE Fast Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Fast Spanning Tree disabled(0)..........no Fast Spanning Tree | 1.3.6.1.4.1.1991.1.1.3.1.42 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwViolatorIfIndex OBJECT-TYPE The port number of the switch or router that received a violator packet. It is included in the locked address violation trap. | 1.3.6.1.4.1.1991.1.1.3.1.43 | Integer32 | read-only | current |
| snSwSingleStpVLanId OBJECT-TYPE The VLAN ID of the Single Spanning Tree VLAN if Single Spanning Tree was enabled. This object returns zero if Single Spanning Tree was disabled. | 1.3.6.1.4.1.1991.1.1.3.1.44 | Integer32 | read-only | current |
| snVLanInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.2 | |||
| snVLanByPortTable OBJECT-TYPE If snSwGroupOperMode is configured as basic mode which is VLAN by Port, Layer2 switching, then this table is valid. Each VLAN switch port could have a number of VLAN IDs. | 1.3.6.1.4.1.1991.1.1.3.2.1 | not-accessible | deprecated | |
| snVLanByPortEntry OBJECT-TYPE An entry in the VLAN By Port Information table. snVLanByPortVLanIndex = 1 and with snVLanByPortVLanId = 1 together implies all attributes applying to the Global switch group i.e. noVLan. A SNMP SET PDU for a row of the snVLanByPortTable requires the entired sequence of the MIB Objects in each snVLanByPortEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.1.3.2.1.1 | not-accessible | deprecated | |
| snVLanByPortVLanIndex OBJECT-TYPE The VLAN ID index must not be greater than the snVLanGroupVlanMaxEntry. Each VLAN Identifier can have a membership of multiple ports. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.1 | INTEGER (1..4095) | read-only | deprecated |
| snVLanByPortVLanId OBJECT-TYPE The VLAN ID index to the VLAN By Port Info Table. Each VLAN Identifier can have a membership of multiple ports. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.2 | INTEGER (1..4095) | read-write | deprecated |
| snVLanByPortPortMask OBJECT-TYPE The Standand-alone switch VLAN port membership. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.1.1.3 | PortMask | read-write | deprecated |
| snVLanByPortQos OBJECT-TYPE The Stand alone stackable switch VLAN Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch VLAN Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) | 1.3.6.1.4.1.1991.1.1.3.2.1.1.4 | INTEGER {level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7)} | read-write | deprecated |
| snVLanByPortStpMode OBJECT-TYPE Spanning Tree Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. disable(0)...........no Spanning Tree enableStp(1).........activate Spanning Tree enableRstp(2)........activate Rapid Spanning Tree | 1.3.6.1.4.1.1991.1.1.3.2.1.1.5 | INTEGER {disable(0), enableStp(1), enableRstp(2)} | read-write | deprecated |
| snVLanByPortStpPriority OBJECT-TYPE dot1dStpPriority : The value of the write-able portion of the Stp ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of the base bridge address - dot1dBaseBridgeAddress. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.6 | INTEGER (0..65535) | read-write | deprecated |
| snVLanByPortStpGroupMaxAge OBJECT-TYPE dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB). The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.7 | INTEGER (0..40) | read-write | deprecated |
| snVLanByPortStpGroupHelloTime OBJECT-TYPE dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB). The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.8 | INTEGER (0..10) | read-write | deprecated |
| snVLanByPortStpGroupForwardDelay OBJECT-TYPE dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB). The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.9 | INTEGER (0..30) | read-write | deprecated |
| snVLanByPortRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.1.1.10 | INTEGER {other(1), valid(2), delete(3), create(4), modify(5)} | read-write | deprecated |
| snVLanByPortOperState OBJECT-TYPE By default, this mode is set to notActivated(0). notActivated(0)...the VLAN entry is not activated and not in running mode. activated(1)......the VLAN entry is activated and in running mode | 1.3.6.1.4.1.1991.1.1.3.2.1.1.11 | INTEGER {notActivated(0), activated(1)} | read-only | deprecated |
| snVLanByPortBaseNumPorts OBJECT-TYPE The number of ports controlled by this bridging entity. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.12 | Integer32 | read-only | deprecated |
| snVLanByPortBaseType OBJECT-TYPE Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.13 | INTEGER {unknown(1), transparentOnly(2), sourcerouteOnly(3), srt(4)} | read-only | deprecated |
| snVLanByPortStpProtocolSpecification OBJECT-TYPE An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.14 | INTEGER {unknown(1), decLb100(2), ieee8021d(3)} | read-only | deprecated |
| snVLanByPortStpMaxAge OBJECT-TYPE dot1dStpMaxAge: From RFC1493(Bridge MIB). The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.15 | Timeout | read-only | deprecated |
| snVLanByPortStpHelloTime OBJECT-TYPE dot1dStpHelloTime: From RFC1493(Bridge MIB). The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.16 | Timeout | read-only | deprecated |
| snVLanByPortStpHoldTime OBJECT-TYPE dot1dStpHoldTime: From RFC1493(Bridge MIB). This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.17 | Integer32 | read-only | deprecated |
| snVLanByPortStpForwardDelay OBJECT-TYPE dot1dStpForwardDelay: From RFC1493(Bridge MIB). This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.] | 1.3.6.1.4.1.1991.1.1.3.2.1.1.18 | Timeout | read-only | deprecated |
| snVLanByPortStpTimeSinceTopologyChange OBJECT-TYPE The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.19 | TimeTicks | read-only | deprecated |
| snVLanByPortStpTopChanges OBJECT-TYPE The total number of topology changes detected by this bridge since the management entity was last reset or initialized. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.20 | Counter32 | read-only | deprecated |
| snVLanByPortStpRootCost OBJECT-TYPE dot1dStpRootCost: From RFC1493(Bridge MIB). The cost of the path to the root as seen from this bridge. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.21 | Integer32 | read-only | deprecated |
| snVLanByPortStpRootPort OBJECT-TYPE dot1dStpRootPort: From RFC1493(Bridge MIB). The port number of the port which offers the lowest cost path from this bridge to the root bridge. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.22 | Integer32 | read-only | deprecated |
| snVLanByPortStpDesignatedRoot OBJECT-TYPE dot1dStpDesignatedRoot: From RFC1493(Bridge MIB). The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.23 | BridgeId | read-only | deprecated |
| snVLanByPortBaseBridgeAddress OBJECT-TYPE The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.24 | MacAddress | read-only | deprecated |
| snVLanByPortVLanName OBJECT-TYPE VLAN Community Name string. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.25 | DisplayString (SIZE(0..32)) | read-write | deprecated |
| snVLanByPortRouterIntf OBJECT-TYPE Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.26 | Integer32 | read-write | deprecated |
| snVLanByPortChassisPortMask OBJECT-TYPE The Chassis VLAN switch port membership. (It was obsoleted after release 07100, replaced by snVLanByPortPortList) | 1.3.6.1.4.1.1991.1.1.3.2.1.1.27 | OCTET STRING | read-write | deprecated |
| snVLanByPortPortList OBJECT-TYPE A list of port indices which are the port membership of a VLAN By Port. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.1.1.28 | OCTET STRING | read-write | deprecated |
| snVLanByProtocolTable OBJECT-TYPE . | 1.3.6.1.4.1.1991.1.1.3.2.2 | not-accessible | current | |
| snVLanByProtocolEntry OBJECT-TYPE An entry in the VLAN By Protocol Configuration table. | 1.3.6.1.4.1.1991.1.1.3.2.2.1 | not-accessible | current | |
| snVLanByProtocolVLanId OBJECT-TYPE The VLAN ID index to both of the VLAN By Port Info Table and this table. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByProtocolIndex OBJECT-TYPE The following IP/IPX protocol VLAN types are operated in Layer3 VLAN such as : ip(1), ipx(2), ipv6(7) The following are operated in Layer2 bridging such as: appleTalk(3), decNet(4), netBios(5), others(6) -- other protocols which are defined here. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.2 | INTEGER {ip(1), ipx(2), appleTalk(3), decNet(4), netBios(5), others(6), ipv6(7)} | read-only | current |
| snVLanByProtocolDynamic OBJECT-TYPE disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snVLanByProtocolStaticMask OBJECT-TYPE The Standand-alone switch Protocol VLAN port membership applied in static mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.4 | PortMask | read-write | deprecated |
| snVLanByProtocolExcludeMask OBJECT-TYPE The Standand-alone switch Protocol VLAN port membership applied in exclusive mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.5 | PortMask | read-write | deprecated |
| snVLanByProtocolRouterIntf OBJECT-TYPE Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.6 | INTEGER (1..60) | read-write | current |
| snVLanByProtocolRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.2.1.7 | INTEGER {other(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snVLanByProtocolDynamicMask OBJECT-TYPE The Standand-alone switch Protocol VLAN active port membership. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.8 | PortMask | read-only | deprecated |
| snVLanByProtocolChassisStaticMask OBJECT-TYPE The Chassis Protocol VLAN port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByProtocolStaticPortList) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.9 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByProtocolChassisExcludeMask OBJECT-TYPE The Chassis Protocol VLAN port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByProtocolExcludePortList) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.10 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByProtocolChassisDynamicMask OBJECT-TYPE The Chassis Protocol VLAN active port membership. (It was obsoleted after release 07100, replaced by snVLanByProtocolDynamicPortList) | 1.3.6.1.4.1.1991.1.1.3.2.2.1.11 | OCTET STRING (SIZE(32)) | read-only | deprecated |
| snVLanByProtocolVLanName OBJECT-TYPE VLAN Community Name string. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.12 | DisplayString (SIZE(0..32)) | read-write | current |
| snVLanByProtocolStaticPortList OBJECT-TYPE A list of port indices which are the configured port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.13 | OCTET STRING | read-write | current |
| snVLanByProtocolExcludePortList OBJECT-TYPE A list of port indices which are the excluded from port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.14 | OCTET STRING | read-write | current |
| snVLanByProtocolDynamicPortList OBJECT-TYPE A list of port indices which are dynamically joining the port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.2.1.15 | OCTET STRING | read-only | current |
| snVLanByIpSubnetTable OBJECT-TYPE An entry of the VLAN By IPX Network Number Table. | 1.3.6.1.4.1.1991.1.1.3.2.3 | not-accessible | current | |
| snVLanByIpSubnetEntry OBJECT-TYPE An entry in the VLAN By IP Subnet Configuration table. | 1.3.6.1.4.1.1991.1.1.3.2.3.1 | not-accessible | current | |
| snVLanByIpSubnetVLanId OBJECT-TYPE The VLAN ID index to both of the VLAN By Port Info Table and this table. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByIpSubnetIpAddress OBJECT-TYPE Subnet IP address. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.2 | IpAddress | read-only | current |
| snVLanByIpSubnetSubnetMask OBJECT-TYPE Subnet mask associated with the Subnet IP address. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.3 | IpAddress | read-only | current |
| snVLanByIpSubnetDynamic OBJECT-TYPE disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snVLanByIpSubnetStaticMask OBJECT-TYPE The Standand-alone switch VLAN By Subnet port membership applied in static mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.5 | PortMask | read-write | deprecated |
| snVLanByIpSubnetExcludeMask OBJECT-TYPE The Standand-alone switch VLAN By Subnet port membership applied in exclusive mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.6 | PortMask | read-write | deprecated |
| snVLanByIpSubnetRouterIntf OBJECT-TYPE Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.7 | INTEGER (1..60) | read-write | current |
| snVLanByIpSubnetRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.3.1.8 | INTEGER {other(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snVLanByIpSubnetDynamicMask OBJECT-TYPE The Standand-alone switch VLAN By Subnet active port membership. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.9 | PortMask | read-only | deprecated |
| snVLanByIpSubnetChassisStaticMask OBJECT-TYPE The Chassis VLAN By Subnet port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetStaticPortList) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.10 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByIpSubnetChassisExcludeMask OBJECT-TYPE The Chassis VLAN By Subnet port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetExcludePortList) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.11 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByIpSubnetChassisDynamicMask OBJECT-TYPE The Chassis VLAN By Subnet active port membership. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetDynamicPortList) | 1.3.6.1.4.1.1991.1.1.3.2.3.1.12 | OCTET STRING (SIZE(32)) | read-only | deprecated |
| snVLanByIpSubnetVLanName OBJECT-TYPE VLAN Community Name string. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.13 | DisplayString (SIZE(0..32)) | read-write | current |
| snVLanByIpSubnetStaticPortList OBJECT-TYPE A list of port indices which are the configured port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.14 | OCTET STRING | read-write | current |
| snVLanByIpSubnetExcludePortList OBJECT-TYPE A list of port indices which are the excluded from port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.15 | OCTET STRING | read-write | current |
| snVLanByIpSubnetDynamicPortList OBJECT-TYPE A list of port indices which are dynamically joining the port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.3.1.16 | OCTET STRING | read-only | current |
| snVLanByIpxNetTable OBJECT-TYPE An entry of the VLAN By IPX Network Number Table. | 1.3.6.1.4.1.1991.1.1.3.2.4 | not-accessible | current | |
| snVLanByIpxNetEntry OBJECT-TYPE An entry in the VLAN By Ipx Network Number Configuration table. | 1.3.6.1.4.1.1991.1.1.3.2.4.1 | not-accessible | current | |
| snVLanByIpxNetVLanId OBJECT-TYPE The VLAN ID index to both of the VLAN By Port Info Table and this table. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByIpxNetNetworkNum OBJECT-TYPE IPX Network Number. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.2 | OCTET STRING (SIZE(4)) | read-only | current |
| snVLanByIpxNetFrameType OBJECT-TYPE The following IPX Frame types are operated in Layer3 VLAN such as : ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4). choose notApplicable(0) for other protocols. Note: Each Network Number can be assigned with one unique Frame type; Otherwise, a SNMP-SET error will be returned. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.3 | INTEGER {notApplicable(0), ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4)} | read-only | current |
| snVLanByIpxNetDynamic OBJECT-TYPE disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snVLanByIpxNetStaticMask OBJECT-TYPE The VLAN By IPX network port membership applied in static mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.5 | PortMask | read-write | deprecated |
| snVLanByIpxNetExcludeMask OBJECT-TYPE The VLAN By IPX network port membership applied in exclusive mode. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.6 | PortMask | read-write | deprecated |
| snVLanByIpxNetRouterIntf OBJECT-TYPE Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.7 | INTEGER (1..60) | read-write | current |
| snVLanByIpxNetRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.4.1.8 | INTEGER {other(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snVLanByIpxNetDynamicMask OBJECT-TYPE The VLAN By IPX network active port membership. (It was obsoleted for Chassis Product) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.9 | PortMask | read-only | deprecated |
| snVLanByIpxNetChassisStaticMask OBJECT-TYPE The Chassis VLAN By IPX network port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByIpxNetStaticPortList) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.10 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByIpxNetChassisExcludeMask OBJECT-TYPE The Chassis VLAN By IPX network port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByIpxNetExcludePortList) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.11 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByIpxNetChassisDynamicMask OBJECT-TYPE The Chassis VLAN By IPX network active port membership. (It was obsoleted after release 07100, replaced by snVLanByIpxNetDynamicPortList) | 1.3.6.1.4.1.1991.1.1.3.2.4.1.12 | OCTET STRING (SIZE(32)) | read-only | deprecated |
| snVLanByIpxNetVLanName OBJECT-TYPE VLAN Community Name string. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.13 | DisplayString (SIZE(0..32)) | read-write | current |
| snVLanByIpxNetStaticPortList OBJECT-TYPE A list of port indices which are the configured port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.14 | OCTET STRING | read-write | current |
| snVLanByIpxNetExcludePortList OBJECT-TYPE A list of port indices which are the excluded from port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.15 | OCTET STRING | read-write | current |
| snVLanByIpxNetDynamicPortList OBJECT-TYPE A list of port indices which are dynamically joining the port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.4.1.16 | OCTET STRING | read-only | current |
| snVLanByATCableTable OBJECT-TYPE A Table Of VLAN By AppleTalk Network Number. | 1.3.6.1.4.1.1991.1.1.3.2.5 | not-accessible | current | |
| snVLanByATCableEntry OBJECT-TYPE An entry of the AppleTalk Cable VLAN table. | 1.3.6.1.4.1.1991.1.1.3.2.5.1 | not-accessible | current | |
| snVLanByATCableVLanId OBJECT-TYPE The VLAN ID of a PORT VLAN of which the AppleTalk Cable VLAN was attaching to. | 1.3.6.1.4.1.1991.1.1.3.2.5.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByATCableIndex OBJECT-TYPE AppleTalk Cable VLAN index number. | 1.3.6.1.4.1.1991.1.1.3.2.5.1.2 | Integer32 | read-only | current |
| snVLanByATCableRouterIntf OBJECT-TYPE A virtual router interface to the AppleTalk Cable VLAN, only router products accept the SNMP-SET operation. The value zero indicates that virtual router interface was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.5.1.3 | INTEGER (0..60) | read-write | current |
| snVLanByATCableRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.5.1.4 | INTEGER {other(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snVLanByATCableChassisStaticMask OBJECT-TYPE A list of ports which are statically configured to become port members of a VLAN. (It was obsoleted after release 07100, replaced by snVLanByATCableStaticPortList) | 1.3.6.1.4.1.1991.1.1.3.2.5.1.5 | OCTET STRING (SIZE(32)) | read-write | deprecated |
| snVLanByATCableVLanName OBJECT-TYPE VLAN Name string. | 1.3.6.1.4.1.1991.1.1.3.2.5.1.6 | DisplayString (SIZE(0..32)) | read-write | current |
| snVLanByATCableStaticPortList OBJECT-TYPE A list of port indices which are the configured port membership of the AppleTalk Cable VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number. | 1.3.6.1.4.1.1991.1.1.3.2.5.1.7 | OCTET STRING | read-write | current |
| snVLanByPortMemberTable OBJECT-TYPE Port VLAN (Layer 2 VLAN) port membership table. | 1.3.6.1.4.1.1991.1.1.3.2.6 | not-accessible | current | |
| snVLanByPortMemberEntry OBJECT-TYPE An entry of the port VLAN membership table. | 1.3.6.1.4.1.1991.1.1.3.2.6.1 | not-accessible | current | |
| snVLanByPortMemberVLanId OBJECT-TYPE The VLAN identifier (VLAN ID). | 1.3.6.1.4.1.1991.1.1.3.2.6.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByPortMemberPortId OBJECT-TYPE The ifIndex which is a member of the port VLAN. | 1.3.6.1.4.1.1991.1.1.3.2.6.1.2 | InterfaceIndex | read-only | current |
| snVLanByPortMemberRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.2.6.1.3 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snVLanByPortMemberTagMode OBJECT-TYPE For tagged/dual-mode port, we could have multiple VLANs per port. For untagged port, there is only one VLAN ID per port. | 1.3.6.1.4.1.1991.1.1.3.2.6.1.4 | INTEGER {tagged(1), untagged(2)} | read-write | current |
| snVLanByPortCfgTable OBJECT-TYPE Port VLAN (Layer 2 VLAN) configuration table. | 1.3.6.1.4.1.1991.1.1.3.2.7 | not-accessible | current | |
| snVLanByPortCfgEntry OBJECT-TYPE An entry of the port VLAN configuration table. | 1.3.6.1.4.1.1991.1.1.3.2.7.1 | not-accessible | current | |
| snVLanByPortCfgVLanId OBJECT-TYPE The VLAN identifier (VLAN ID). | 1.3.6.1.4.1.1991.1.1.3.2.7.1.1 | INTEGER (1..4095) | read-only | current |
| snVLanByPortCfgQos OBJECT-TYPE The Stand alone stackable switch VLAN Priority values are: level0(0) -- low prority level1(1) -- high prority. The BigIron switch VLAN Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7). Value invalid(127) is used by CES/CER products to signify that no QoS was specified for this VLAN. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.2 | PortQosTC | read-write | current |
| snVLanByPortCfgStpMode OBJECT-TYPE Spanning Tree Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. disable(0)...........no Spanning Tree enableStp(1).........activate Spanning Tree enableRstp(2)........activate Rapid Spanning Tree | 1.3.6.1.4.1.1991.1.1.3.2.7.1.3 | INTEGER {disable(0), enableStp(1), enableRstp(2)} | read-write | current |
| snVLanByPortCfgStpPriority OBJECT-TYPE dot1dStpPriority : The value of the write-able portion of the Stp ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of the base bridge address - dot1dBaseBridgeAddress. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.4 | INTEGER (0..65535) | read-write | current |
| snVLanByPortCfgStpGroupMaxAge OBJECT-TYPE dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB). The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. Valid value betweek 6 and 40. Default is 20 seconds. Value 0 is returned if no STP is not configured for this vlan. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.5 | Integer32 | read-write | current |
| snVLanByPortCfgStpGroupHelloTime OBJECT-TYPE dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB). The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. Valid value betweek 1 and 10. Default is 2 seconds. Value 0 is returned if no STP is not configured for this vlan. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.6 | Integer32 | read-write | current |
| snVLanByPortCfgStpGroupForwardDelay OBJECT-TYPE dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB). The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds. Valid value betweek 2 and 30. Default is 15 seconds. Value 0 is returned if no STP is not configured for this vlan. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.7 | Integer32 | read-write | current |
| snVLanByPortCfgBaseNumPorts OBJECT-TYPE The number of ports controlled by this bridging entity. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.8 | Integer32 | read-only | current |
| snVLanByPortCfgBaseType OBJECT-TYPE Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.9 | INTEGER {unknown(1), transparentOnly(2), sourcerouteOnly(3), srt(4)} | read-only | current |
| snVLanByPortCfgStpProtocolSpecification OBJECT-TYPE An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.10 | INTEGER {unknown(1), decLb100(2), ieee8021d(3)} | read-only | current |
| snVLanByPortCfgStpMaxAge OBJECT-TYPE dot1dStpMaxAge: From RFC1493(Bridge MIB). The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.11 | Timeout | read-only | current |
| snVLanByPortCfgStpHelloTime OBJECT-TYPE dot1dStpHelloTime: From RFC1493(Bridge MIB). The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.12 | Timeout | read-only | current |
| snVLanByPortCfgStpHoldTime OBJECT-TYPE dot1dStpHoldTime: From RFC1493(Bridge MIB). This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.13 | Integer32 | read-only | current |
| snVLanByPortCfgStpForwardDelay OBJECT-TYPE dot1dStpForwardDelay: From RFC1493(Bridge MIB). This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.] | 1.3.6.1.4.1.1991.1.1.3.2.7.1.14 | Timeout | read-only | current |
| snVLanByPortCfgStpTimeSinceTopologyChange OBJECT-TYPE The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.15 | TimeTicks | read-only | current |
| snVLanByPortCfgStpTopChanges OBJECT-TYPE The total number of topology changes detected by this bridge since the management entity was last reset or initialized. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.16 | Counter32 | read-only | current |
| snVLanByPortCfgStpRootCost OBJECT-TYPE dot1dStpRootCost: From RFC1493(Bridge MIB). The cost of the path to the root as seen from this bridge. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.17 | Integer32 | read-only | current |
| snVLanByPortCfgStpRootPort OBJECT-TYPE dot1dStpRootPort: From RFC1493(Bridge MIB). The port number of the port which offers the lowest cost path from this bridge to the root bridge. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.18 | Integer32 | read-only | current |
| snVLanByPortCfgStpDesignatedRoot OBJECT-TYPE dot1dStpDesignatedRoot: From RFC1493(Bridge MIB). The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.19 | BridgeId | read-only | current |
| snVLanByPortCfgBaseBridgeAddress OBJECT-TYPE The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.20 | MacAddress | read-only | current |
| snVLanByPortCfgVLanName OBJECT-TYPE VLAN Community Name string. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.21 | DisplayString (SIZE(0..32)) | read-write | current |
| snVLanByPortCfgRouterIntf OBJECT-TYPE Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.22 | Integer32 | read-write | current |
| snVLanByPortCfgRowStatus OBJECT-TYPE Use this object to delete a vlan entry. For read operation, its value is 'valid' if it is a user-configured VLAN and 'other' if it is a control-VLAN. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.23 | INTEGER {other(1), valid(2), delete(3)} | read-write | current |
| snVLanByPortCfgStpVersion OBJECT-TYPE The version of Spanning Tree Protocol the bridge is currently running. The value 'stpCompatible(0)' indicates the Spanning Tree Protocol specified in IEEE 802.1D and 'rstp(2)' indicates the Rapid Spanning Tree Protocol specified in IEEE 802.1w. New value may be defined as future versions of the protocol become available. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.24 | INTEGER {stpCompatible(0), rstp(2)} | read-write | current |
| snVLanByPortCfgInOctets OBJECT-TYPE The number of bytes received on this VLAN. This can be used as the per VE couter, if there is one-to-one map for VLAN-VE. | 1.3.6.1.4.1.1991.1.1.3.2.7.1.25 | Counter64 | read-only | current |
| brcdVlanExtStatsTable OBJECT-TYPE This table contains the extended statistics for VLAN ports of G2 cards. These applies to L2 VLANs and as well as port VLANs that are associated to IP interfaces (physical or VE). | 1.3.6.1.4.1.1991.1.1.3.2.8 | not-accessible | current | |
| brcdVlanExtStatsEntry OBJECT-TYPE A row in this table represents a VLAN extended statistics accounting entry. It can be a per-VLAN/port entry, in this case the Priority-ID is 128 (invalid). It can also be in a priority level granularity of the VLAN port, in this case the Priority-ID specifies which port QOS priority, and Priority-ID 128 is the index to the aggregate count bucket. | 1.3.6.1.4.1.1991.1.1.3.2.8.1 | not-accessible | current | |
| brcdVlanExtStatsVlanId OBJECT-TYPE The VLAN identifier (VLAN ID). | 1.3.6.1.4.1.1991.1.1.3.2.8.1.1 | BrcdVlanIdTC | not-accessible | current |
| brcdVlanExtStatsIfIndex OBJECT-TYPE The ifIndex of the port belonging to this VLAN. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.2 | InterfaceIndex | not-accessible | current |
| brcdVlanExtStatsPriorityId OBJECT-TYPE Identifies the port QOS priority. The values 1 through 8 internally maps to priorities 0 through 7. The value 128 indicates that priority-level accounting is not enabled | 1.3.6.1.4.1.1991.1.1.3.2.8.1.3 | PortPriorityTC | not-accessible | current |
| brcdVlanExtStatsInSwitchedPkts OBJECT-TYPE The number of valid frames received by this port classified as belonging to this VLAN for switched packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.4 | Counter64 | read-only | current |
| brcdVlanExtStatsInRoutedPkts OBJECT-TYPE The number of valid frames received by this port classified as belonging to this VLAN for routed packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.5 | Counter64 | read-only | current |
| brcdVlanExtStatsInPkts OBJECT-TYPE The number of valid frames received by this port classified as belonging to this VLAN for both switched and routed packets. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.6 | Counter64 | read-only | current |
| brcdVlanExtStatsOutSwitchedPkts OBJECT-TYPE The number of valid frames transmitted by this port classified as belonging to this VLAN for switched packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.7 | Counter64 | read-only | current |
| brcdVlanExtStatsOutRoutedPkts OBJECT-TYPE The number of valid frames transmitted by this port classified as belonging to this VLAN for routed packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.8 | Counter64 | read-only | current |
| brcdVlanExtStatsOutPkts OBJECT-TYPE The number of valid frames transmitted by this port classified as belonging to this VLAN for both switched and routed packets. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.9 | Counter64 | read-only | current |
| brcdVlanExtStatsInSwitchedOctets OBJECT-TYPE The bytes count received by this port classified as belonging to this VLAN for switched packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.10 | Counter64 | read-only | current |
| brcdVlanExtStatsInRoutedOctets OBJECT-TYPE The bytes count received by this port classified as belonging to this VLAN for routed packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.11 | Counter64 | read-only | current |
| brcdVlanExtStatsInOctets OBJECT-TYPE The bytes count received by this port classified as belonging to this VLAN for both switched and routed packets. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.12 | Counter64 | read-only | current |
| brcdVlanExtStatsOutSwitchedOctets OBJECT-TYPE The bytes count transmitted by this port classified as belonging to this VLAN for switched packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.13 | Counter64 | read-only | current |
| brcdVlanExtStatsOutRoutedOctets OBJECT-TYPE The bytes count transmitted by this port classified as belonging to this VLAN for routed packets. The value is applicable only if the system was configured to separately count the two types of packets. Otherwise, it returns 0. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.14 | Counter64 | read-only | current |
| brcdVlanExtStatsOutOctets OBJECT-TYPE The bytes count transmitted by this port classified as belonging to this VLAN for both switched and routed packets. | 1.3.6.1.4.1.1991.1.1.3.2.8.1.15 | Counter64 | read-only | current |
| snSwPortInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3 | |||
| snSwPortInfoTable OBJECT-TYPE A specific snSwPortInfo group consists of a number of switch ports. | 1.3.6.1.4.1.1991.1.1.3.3.1 | not-accessible | deprecated | |
| snSwPortInfoEntry OBJECT-TYPE An entry in the snSwPortInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snSwPortInfoTable requires the entired sequence of the MIB Objects in each snSwPortInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.1.3.3.1.1 | not-accessible | deprecated | |
| snSwPortInfoPortNum OBJECT-TYPE The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only). | 1.3.6.1.4.1.1991.1.1.3.3.1.1.1 | Integer32 | read-only | deprecated |
| snSwPortInfoMonitorMode OBJECT-TYPE DEPRECATED by snSwPortInfoMirrorMode and snPortMonitorTable. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.2 | INTEGER {disabled(0), input(1), output(2), both(3)} | read-write | deprecated |
| snSwPortInfoTagMode OBJECT-TYPE For tagged port, we could have multiple VLANs per port. For untagged port or auto port, there is only one VLAN ID per port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.3 | INTEGER {tagged(1), untagged(2), auto(3), disabled(4)} | read-write | deprecated |
| snSwPortInfoChnMode OBJECT-TYPE The port can be configured to operate in either half or full duplex mode. The values are: halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The read-back channel status from hardware are: none(0).........link down or port disabled. halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The port media type (expansion or regular) and port link type (trunk or feeder) determine value of this object. The port can not set to half duplex mode if the port connect mode is m200e(4). However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device). | 1.3.6.1.4.1.1991.1.1.3.3.1.1.4 | INTEGER {none(0), halfDuplex(1), fullDuplex(2)} | read-write | deprecated |
| snSwPortInfoSpeed OBJECT-TYPE The speed configuration for a port. The values are: none(0)..........link down or no traffic. sAutoSense(1)....Auto-sensing 10 or 100Mbits. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s1GM(5)..........1Gbits per second master. s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. s622M(8).........OC12 - 622Mbits per second s2488M(9)........OC48 - 2.488Gbits per second s9953M(10).......OC192 - 9.953Gbits per second s16G(11)..........16Gbits per second. s40G(13)..........40Gbits per second. The read-back hardware status are the following: none(0)..........link down or no traffic. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s1GM(5)..........1Gbits per second master. s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. s622M(8).........OC12 - 622Mbits per second s2488M(9)........OC48 - 2.488Gbits per second s9953M(10).......OC192 - 9.953Gbits per second s16G(11)..........16Gbits per second. s40G(13)..........40Gbits per second. The port media type (expansion or regular) and port link type (trunk or feeder) determine whether this object can be written and the valid values. It is not allowed to change speed for trunks ports. For expansion ports, all of the above speed can be set. However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device). | 1.3.6.1.4.1.1991.1.1.3.3.1.1.5 | INTEGER {none(0), sAutoSense(1), s10M(2), s100M(3), s1G(4), s1GM(5), s155M(6), s10G(7), s622M(8), s2488M(9), s9953M(10), s16G(11), s40G(13)} | read-write | deprecated |
| snSwPortInfoMediaType OBJECT-TYPE The media type for the port. The values are: other(1).........other or unknown media. m100BaseTX(2)....100Mbits per second copper. m100BaseFX(3)....100Mbits per second fiber. m1000BaseFX(4)...1Gbits per second fiber. mT3(5)...........45Mbits per second (T3). m155ATM(6).......155Mbits per second (ATM). m1000BaseTX(7)...1Gbits per second copper. m622ATM(8).......622Mbits per second (ATM). m155POS(9).......155Mbits per second (POS). m622POS(10)......622Mbits per second (POS). m2488POS(11).....2488Mbits per second (POS). m10000BaseFX(12).10Gbits per second fiber. m9953POS(13).....9953Mbits per second (POS). m16GStacking(14).16Gbits per second fiber. m40GStacking(16). 40Gbits per second fiber. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.6 | INTEGER {other(1), m100BaseTX(2), m100BaseFX(3), m1000BaseFX(4), mT3(5), m155ATM(6), m1000BaseTX(7), m622ATM(8), m155POS(9), m622POS(10), m2488POS(11), m10000BaseFX(12), m9953POS(13), m16GStacking(14), m40GStacking(16)} | read-only | deprecated |
| snSwPortInfoConnectorType OBJECT-TYPE The type of connector that the port offers. The values are: other(1)...........other or unknown connector copper(2)..........Copper connector fiber(3)...........Fiber connector This describes the physical connector type | 1.3.6.1.4.1.1991.1.1.3.3.1.1.7 | INTEGER {other(1), copper(2), fiber(3)} | read-only | deprecated |
| snSwPortInfoAdminStatus OBJECT-TYPE The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II) | 1.3.6.1.4.1.1991.1.1.3.3.1.1.8 | INTEGER {up(1), down(2), testing(3)} | read-write | deprecated |
| snSwPortInfoLinkStatus OBJECT-TYPE The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II) | 1.3.6.1.4.1.1991.1.1.3.3.1.1.9 | INTEGER {up(1), down(2), testing(3)} | read-only | deprecated |
| snSwPortInfoPortQos OBJECT-TYPE The Stand alone stackable switch Port Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron Port Qos Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) | 1.3.6.1.4.1.1991.1.1.3.3.1.1.10 | INTEGER {level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7)} | read-write | deprecated |
| snSwPortInfoPhysAddress OBJECT-TYPE The port physical address. The physical address represents the switch port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.11 | PhysAddress | read-only | deprecated |
| snSwPortStatsInFrames OBJECT-TYPE The total number of packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.12 | Counter32 | read-only | deprecated |
| snSwPortStatsOutFrames OBJECT-TYPE The total number of packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.13 | Counter32 | read-only | deprecated |
| snSwPortStatsAlignErrors OBJECT-TYPE dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.14 | Counter32 | read-only | deprecated |
| snSwPortStatsFCSErrors OBJECT-TYPE dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.15 | Counter32 | read-only | deprecated |
| snSwPortStatsMultiColliFrames OBJECT-TYPE dot3StatsMultipleCollisionFrames : A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsSingleCollisionFrames object. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.16 | Counter32 | read-only | deprecated |
| snSwPortStatsFrameTooLongs OBJECT-TYPE dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.17 | Counter32 | read-only | deprecated |
| snSwPortStatsTxColliFrames OBJECT-TYPE A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by a combination of both dot3StatsSingleCollisionFrames and dot3StatsMultipleCollisionFrames objects. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.18 | Counter32 | read-only | deprecated |
| snSwPortStatsRxColliFrames OBJECT-TYPE A count of successfully received frames on a particular interface for which transmission is inhibited by more than one collision. This object is not specified in dot3 but it has the same functionarity as snSwPortStatsTxColliFrames. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.19 | Counter32 | read-only | deprecated |
| snSwPortStatsFrameTooShorts OBJECT-TYPE A count of frames received on a particular interface that below the minimum permitted frame size. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.20 | Counter32 | read-only | deprecated |
| snSwPortLockAddressCount OBJECT-TYPE The number of source MAC addresses are allowed for a port. Writing 0 to this object will allow any number of addresses. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.21 | INTEGER (0..2048) | read-write | deprecated |
| snSwPortStpPortEnable OBJECT-TYPE The enabled/disabled status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snSwPortDhcpGateListId OBJECT-TYPE The ID for a DHCP gateway list entry relative to this switch port. 0 = unset or no assigned ID | 1.3.6.1.4.1.1991.1.1.3.3.1.1.23 | INTEGER (0..32) | read-write | deprecated |
| snSwPortName OBJECT-TYPE Port Name string. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.24 | DisplayString (SIZE(0..255)) | read-write | deprecated |
| snSwPortStatsInBcastFrames OBJECT-TYPE The total number of broadcast packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.25 | Counter32 | read-only | deprecated |
| snSwPortStatsOutBcastFrames OBJECT-TYPE The total number of broadcast packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.26 | Counter32 | read-only | deprecated |
| snSwPortStatsInMcastFrames OBJECT-TYPE The total number of multicast packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.27 | Counter32 | read-only | deprecated |
| snSwPortStatsOutMcastFrames OBJECT-TYPE The total number of multicast packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.28 | Counter32 | read-only | deprecated |
| snSwPortStatsInDiscard OBJECT-TYPE The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.29 | Counter32 | read-only | deprecated |
| snSwPortStatsOutDiscard OBJECT-TYPE The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.30 | Counter32 | read-only | deprecated |
| snSwPortStatsMacStations OBJECT-TYPE The total number of MAC Stations connected to the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.31 | Integer32 | read-only | deprecated |
| snSwPortCacheGroupId OBJECT-TYPE Cache Group ID for the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.32 | Integer32 | read-write | deprecated |
| snSwPortTransGroupId OBJECT-TYPE Transparent Group ID for the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.33 | Integer32 | read-write | deprecated |
| snSwPortInfoAutoNegotiate OBJECT-TYPE This feature only applies to Gigabit Ethernet ports. If set to disable(0), port will be put to non-negotiation mode. If set to enable(1), port will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), the port will start with auto- negotiation, if the negotiation failed, then it will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If set to global(3), port negotiation mode follows the value of snSwGlobalAutoNegotiate. Non-Gigabit Ethernet port returns the value other(4). | 1.3.6.1.4.1.1991.1.1.3.3.1.1.34 | INTEGER {disabled(0), enabled(1), negFullAuto(2), global(3), other(4)} | read-write | deprecated |
| snSwPortInfoFlowControl OBJECT-TYPE Enable/Disbale port flow control. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.35 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snSwPortInfoGigType OBJECT-TYPE The media type for the port. The values are: m1000BaseSX(0)....1Gbits per second fiber, with a short wavelength transceiver. m1000BaseLX(1)....1Gbits per second fiber, with a long wavelength transceiver (3km). m1000BaseLH(2)....1Gbits per second fiber, with a special wavelength transceiver (50km). m1000BaseLHA(3)....1Gbits per second fiber, with a special wavelength transceiver (70km). m1000BaseLHB(4)....1Gbits per second fiber, with a special wavelength transceiver (150km). m1000BaseTX(5)....1Gbits per second copper (100meter). m10000BaseSR(6)....10Gbits per second fiber, with a short range wavelength transceiver (100m). m10000BaseLR(7)....10Gbits per second fiber, with a long range wavelength transceiver (10km). m10000BaseER(8)....10Gbits per second fiber, with a extended range wavelength transceiver (40km). sfpCWDM1470nm80Km(9)....1Gbits per second CWDM fiber, with a wavelength 1470nm, reach 80 kms. sfpCWDM1490nm80Km(10)....1Gbits per second CWDM fiber, with a wavelength 1490nm, reach 80 kms. sfpCWDM1510nm80Km(11)....1Gbits per second CWDM fiber, with a wavelength 1510nm, reach 80 kms. sfpCWDM1530nm80Km(12)....1Gbits per second CWDM fiber, with a wavelength 1530nm, reach 80 kms. sfpCWDM1550nm80Km(13)....1Gbits per second CWDM fiber, with a wavelength 1550nm, reach 80 kms. sfpCWDM1570nm80Km(14)....1Gbits per second CWDM fiber, with a wavelength 1570nm, reach 80 kms. sfpCWDM1590nm80Km(15)....1Gbits per second CWDM fiber, with a wavelength 1590nm, reach 80 kms. sfpCWDM1610nm80Km(16)....1Gbits per second CWDM fiber, with a wavelength 1610nm, reach 80 kms. sfpCWDM1470nm100Km(17)....1Gbits per second CWDM fiber, with a wavelength 1470nm, reach 100 kms. sfpCWDM1490nm100Km(18)....1Gbits per second CWDM fiber, with a wavelength 1490nm, reach 100 kms. sfpCWDM1510nm100Km(19)....1Gbits per second CWDM fiber, with a wavelength 1510nm, reach 100 kms. sfpCWDM1530nm100Km(20)....1Gbits per second CWDM fiber, with a wavelength 1530nm, reach 100 kms. sfpCWDM1550nm100Km(21)....1Gbits per second CWDM fiber, with a wavelength 1550nm, reach 100 kms. sfpCWDM1570nm100Km(22)....1Gbits per second CWDM fiber, with a wavelength 1570nm, reach 100 kms. sfpCWDM1590nm100Km(23)....1Gbits per second CWDM fiber, with a wavelength 1590nm, reach 100 kms. sfpCWDM1610nm100Km(24)....1Gbits per second CWDM fiber, with a wavelength 1610nm, reach 100 kms. m1000BaseLHX(25)...1Gbits per second fiber, with a special wavelength transceiver (150km). notApplicable(255)....a non-gigabit port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.36 | INTEGER {m1000BaseSX(0), m1000BaseLX(1), m1000BaseLH(2), m1000BaseLHA(3), m1000BaseLHB(4), m1000BaseTX(5), m10000BaseSR(6), m10000BaseLR(7), m10000BaseER(8), sfpCWDM1470nm80Km(9), sfpCWDM1490nm80Km(10), sfpCWDM1510nm80Km(11), sfpCWDM1530nm80Km(12), sfpCWDM1550nm80Km(13), sfpCWDM1570nm80Km(14), sfpCWDM1590nm80Km(15), sfpCWDM1610nm80Km(16), sfpCWDM1470nm100Km(17), sfpCWDM1490nm100Km(18), sfpCWDM1510nm100Km(19), sfpCWDM1530nm100Km(20), sfpCWDM1550nm100Km(21), sfpCWDM1570nm100Km(22), sfpCWDM1590nm100Km(23), sfpCWDM1610nm100Km(24), m1000BaseLHX(25), m1000BaseSX2(26), m1000BaseGBXU(27), m1000BaseGBXD(28), notApplicable(255)} | read-only | deprecated |
| snSwPortStatsLinkChange OBJECT-TYPE The total number of link state change of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.37 | Counter32 | read-only | deprecated |
| snSwPortIfIndex OBJECT-TYPE In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.38 | Integer32 | read-only | deprecated |
| snSwPortDescr OBJECT-TYPE A textual string containing the slot/port information about the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.39 | DisplayString | read-only | deprecated |
| snSwPortInOctets OBJECT-TYPE The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.40 | OCTET STRING (SIZE(8)) | read-only | deprecated |
| snSwPortOutOctets OBJECT-TYPE The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.41 | OCTET STRING (SIZE(8)) | read-only | deprecated |
| snSwPortStatsInBitsPerSec OBJECT-TYPE The number of bits per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.42 | Gauge32 | read-only | deprecated |
| snSwPortStatsOutBitsPerSec OBJECT-TYPE The number of bits per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.43 | Gauge32 | read-only | deprecated |
| snSwPortStatsInPktsPerSec OBJECT-TYPE The number of packets per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.44 | Gauge32 | read-only | deprecated |
| snSwPortStatsOutPktsPerSec OBJECT-TYPE The number of packets per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.45 | Gauge32 | read-only | deprecated |
| snSwPortStatsInUtilization OBJECT-TYPE The input network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.46 | INTEGER (0..10000) | read-only | deprecated |
| snSwPortStatsOutUtilization OBJECT-TYPE The output network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.47 | INTEGER (0..10000) | read-only | deprecated |
| snSwPortFastSpanPortEnable OBJECT-TYPE The enabled/disabled fast span port status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.48 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snSwPortFastSpanUplinkEnable OBJECT-TYPE The enabled/disabled fast span uplink status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.49 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snSwPortVlanId OBJECT-TYPE The ID of a VLAN of which this port is a member. Port must be untagged. For tagged port which belongs to multiple VLANs, this object return 0 which is an invalid VLAN ID value. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.50 | INTEGER (0..4095) | read-write | deprecated |
| snSwPortRouteOnly OBJECT-TYPE Enable/Disable L2 switching of a routing switch port. By default, the routing switch performs routing first. If routing failed, it performs switching. Enable route only instrcuts the routing switch to perform routing only. For a L2 switching only product, reading this object always return 'disabled', writing 'enabled' to this object takes no effect. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.51 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| snSwPortPresent OBJECT-TYPE Indicate if the port is absent or present. This object only valid for M4 module | 1.3.6.1.4.1.1991.1.1.3.3.1.1.52 | INTEGER {false(0), true(1)} | read-only | deprecated |
| snSwPortGBICStatus OBJECT-TYPE Indicate if the gig port has GBICs on them. If set to GBIC(1), it means that the port is GBIC. If set to miniGBIC(2), it means that the port miniGBIC. If set to empty(3), it means that the GBIC is missing. Value other(4) means that the port not a removable gig port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.53 | INTEGER {gbic(1), miniGBIC(2), empty(3), other(4)} | read-only | deprecated |
| snSwPortStatsInKiloBitsPerSec OBJECT-TYPE Bit rate in kilobits per second received on the 10G and faster interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.54 | Unsigned32 | read-only | deprecated |
| snSwPortStatsOutKiloBitsPerSec OBJECT-TYPE Bit rate in kilobits per second transmitted out of the 10G and faster interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.55 | Unsigned32 | read-only | deprecated |
| snSwPortLoadInterval OBJECT-TYPE The time in seconds for which average port utilization should be carried out. The value should be incremental of 30 seconds, between the ranges specified. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.56 | INTEGER (30..300) | read-write | deprecated |
| snSwPortTagType OBJECT-TYPE The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.57 | Integer32 | read-write | deprecated |
| snSwPortInLinePowerControl OBJECT-TYPE Control inline power on/off to a port. If a port does not have inline power capability, reading this object returns 'other(1)'. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.58 | INTEGER {other(1), disable(2), enable(3), enableLegacyDevice(4)} | read-write | deprecated |
| snSwPortInLinePowerWattage OBJECT-TYPE Adjust the inline power wattage. Valid value between 1000 and 15400. Each unit is milliwatts. This object can only be set after snSwPortInLinePowerControl has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If a port does not have inline power capability, reading this object returns undefined value. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.59 | Integer32 | read-write | deprecated |
| snSwPortInLinePowerClass OBJECT-TYPE Adjust the inline power class. This object can only be set after snSwPortInLinePowerControl has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If a port does not have inline power capability, reading this object returns undefined value. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.60 | INTEGER (0..3) | read-write | deprecated |
| snSwPortInLinePowerPriority OBJECT-TYPE Inline power allocation priority for the power device 0- Not a POE port, 1- Critical, 2- High, 3- Low, 4- Medium, 5- other. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.61 | INTEGER {invalid(0), critical(1), high(2), low(3), medium(4), other(5)} | read-write | deprecated |
| snSwPortInfoMirrorMode OBJECT-TYPE Enable/disable mirror on this port. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.62 | INTEGER {disable(0), enable(1)} | read-write | deprecated |
| snSwPortStatsInJumboFrames OBJECT-TYPE The total number of jumbo packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.63 | Counter64 | read-only | deprecated |
| snSwPortStatsOutJumboFrames OBJECT-TYPE The total number of jumbo packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.64 | Counter64 | read-only | deprecated |
| snSwPortInLinePowerConsumed OBJECT-TYPE Inline power consumed by the port. Each unit is milliwatts. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.66 | Integer32 | read-only | deprecated |
| snSwPortInLinePowerPDType OBJECT-TYPE Inline Power device type 802.3af or Legacy device. | 1.3.6.1.4.1.1991.1.1.3.3.1.1.67 | DisplayString | read-only | deprecated |
| snInterfaceId OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2 | |||
| snEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.1 | |||
| snPosInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.2 | |||
| snAtmInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.3 | |||
| snVirtualInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.4 | |||
| snLoopbackInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.5 | |||
| snGreTunnelInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.6 | |||
| snSubInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.7 | |||
| snMplsTunnelInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.8 | |||
| snPvcInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.9 | |||
| snMgmtEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.10 | |||
| snTrunkInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.11 | |||
| snVirtualMgmtInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.12 | |||
| sn6to4TunnelInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.3.2.13 | |||
| snInterfaceLookupTable OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.3 | not-accessible | current | |
| snInterfaceLookupEntry OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.3.1 | not-accessible | current | |
| snInterfaceLookupInterfaceId OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.3.1.1 | InterfaceId | read-only | current |
| snInterfaceLookupIfIndex OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.3.1.2 | Integer32 | read-only | current |
| snIfIndexLookupTable OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.4 | not-accessible | current | |
| snIfIndexLookupEntry OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.4.1 | not-accessible | current | |
| snIfIndexLookupIfIndex OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.4.1.1 | Integer32 | read-only | current |
| snIfIndexLookupInterfaceId OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.4.1.2 | InterfaceId | read-only | current |
| snSwIfInfoTable OBJECT-TYPE A specific snSwIfInfo group consists of a number of switch ports. | 1.3.6.1.4.1.1991.1.1.3.3.5 | not-accessible | current | |
| snSwIfInfoEntry OBJECT-TYPE An entry in the snSwIfInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snSwIfInfoTable requires the entire sequence of the MIB Objects in each snSwIfInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.1.3.3.5.1 | not-accessible | current | |
| snSwIfInfoPortNum OBJECT-TYPE The port/interface index (ifindex). | 1.3.6.1.4.1.1991.1.1.3.3.5.1.1 | InterfaceIndex | read-only | current |
| snSwIfInfoMonitorMode OBJECT-TYPE DEPRECATED by snSwIf2MirrorMode and snPortMonitorTable. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.2 | INTEGER {disabled(0), input(1), output(2), both(3)} | read-write | deprecated |
| snSwIfInfoMirrorPorts OBJECT-TYPE The list of port/interface index (ifindex), which mirror this interface, when monitoring is enabled. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.3 | OCTET STRING | read-write | current |
| snSwIfInfoTagMode OBJECT-TYPE For tagged/dual port, we could have multiple VLANs per port. For untagged port, there is only one VLAN ID per port, dual mode is associated with a vlan id 'snSwIfVlanId', dual mode with snSwIfVlanId zero disables the dual mode. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.4 | INTEGER {tagged(1), untagged(2), dual(3)} | read-write | current |
| snSwIfInfoTagType OBJECT-TYPE The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.5 | Integer32 | read-write | current |
| snSwIfInfoChnMode OBJECT-TYPE The port can be configured to operate in either half or full duplex mode. The values are: none(0) is not used. halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The read-back channel status from hardware are: halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The port media type (expansion or regular) and port link type (trunk or feeder) determine value of this object. The port can not set to half duplex mode if the port connect mode is m200e(4). However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device). | 1.3.6.1.4.1.1991.1.1.3.3.5.1.6 | INTEGER {none(0), halfDuplex(1), fullDuplex(2)} | read-write | current |
| snSwIfInfoSpeed OBJECT-TYPE The speed configuration for a port. The values are: none(0)..........not used. sAutoSense(1)....Auto-sensing 10 or 100Mbits. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s1GM(5)..........1Gbits per second master. s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. s622M(8).........OC12 - 622Mbits per second s2488M(9)........OC48 - 2.488Gbits per second s9953M(10).......OC192 - 9.953Gbits per second s16G(11)..........16Gbits per second. s40G(13)..........40Gbits per second. The read-back hardware status are the following: s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s1GM(5)..........1Gbits per second master. s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. s622M(8).........OC12 - 622Mbits per second s2488M(9)........OC48 - 2.488Gbits per second s9953M(10).......OC192 - 9.953Gbits per second s16G(11)..........16Gbits per second. s40G(13)..........40Gbits per second. The port media type (expansion or regular) and port link type (trunk or feeder) determine whether this object can be written and the valid values. It is not allowed to change speed for trunks ports. For expansion ports, all of the above speed can be set. However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device). | 1.3.6.1.4.1.1991.1.1.3.3.5.1.7 | INTEGER {none(0), sAutoSense(1), s10M(2), s100M(3), s1G(4), s1GM(5), s155M(6), s10G(7), s622M(8), s2488M(9), s9953M(10), s16G(11), s100G(12), s40G(13)} | read-write | current |
| snSwIfInfoMediaType OBJECT-TYPE The media type for the port. The values are: other(1).........other or unknown media. m100BaseTX(2)....100Mbits per second copper. m100BaseFX(3)....100Mbits per second fiber. m1000BaseFX(4)...1Gbits per second fiber. mT3(5)...........45Mbits per second (T3). m155ATM(6).......155Mbits per second (ATM). m1000BaseTX(7)...1Gbits per second copper. m622ATM(8).......622Mbits per second (ATM). m155POS(9).......155Mbits per second (POS). m622POS(10)......622Mbits per second (POS). m2488POS(11).....2488Mbits per second (POS). m10000BaseFX(12).10Gbits per second fiber. m9953POS(13).....9953Mbits per second (POS). m16GStacking(14)...16Gbits per second fiber. m40GStacking(16). 40Gbits per second fiber. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.8 | INTEGER {other(1), m100BaseTX(2), m100BaseFX(3), m1000BaseFX(4), mT3(5), m155ATM(6), m1000BaseTX(7), m622ATM(8), m155POS(9), m622POS(10), m2488POS(11), m10000BaseFX(12), m9953POS(13), m16GStacking(14), m100GBaseFX(15), m40GStacking(16)} | read-only | current |
| snSwIfInfoConnectorType OBJECT-TYPE The type of connector that the port offers. The values are: other(1)...........other or unknown connector copper(2)..........Copper connector fiber(3)...........Fiber connector This describes the physical connector type | 1.3.6.1.4.1.1991.1.1.3.3.5.1.9 | INTEGER {other(1), copper(2), fiber(3)} | read-only | current |
| snSwIfInfoAdminStatus OBJECT-TYPE The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II) | 1.3.6.1.4.1.1991.1.1.3.3.5.1.10 | INTEGER {up(1), down(2), testing(3)} | read-write | current |
| snSwIfInfoLinkStatus OBJECT-TYPE The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II) | 1.3.6.1.4.1.1991.1.1.3.3.5.1.11 | INTEGER {up(1), down(2), testing(3)} | read-only | current |
| snSwIfInfoPortQos OBJECT-TYPE The Stand alone stackable switch Port Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron Port Qos Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) | 1.3.6.1.4.1.1991.1.1.3.3.5.1.12 | INTEGER {level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7)} | read-write | current |
| snSwIfInfoPhysAddress OBJECT-TYPE The port physical address. The physical address represents the switch port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.13 | PhysAddress | read-only | current |
| snSwIfLockAddressCount OBJECT-TYPE The number of source MAC addresses are allowed for a port. Writing 0 to this object will allow any number of addresses. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.14 | INTEGER (0..2048) | read-write | current |
| snSwIfStpPortEnable OBJECT-TYPE The enabled/disabled status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIfDhcpGateListId OBJECT-TYPE The ID for a DHCP gateway list entry relative to this switch port. 0 = unset or no assigned ID | 1.3.6.1.4.1.1991.1.1.3.3.5.1.16 | INTEGER (0..32) | read-write | current |
| snSwIfName OBJECT-TYPE Port Name string. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.17 | DisplayString (SIZE(0..255)) | read-write | current |
| snSwIfDescr OBJECT-TYPE A textual string containing the slot/port information about the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.18 | DisplayString | read-only | current |
| snSwIfInfoAutoNegotiate OBJECT-TYPE This feature only applies to Gigabit Ethernet ports. If set to disable(0), port will be put to non-negotiation mode. If set to enable(1), port will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), the port will start with auto- negotiation, if the negotiation failed, then it will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If set to global(3), port negotiation mode follows the value of snSwGlobalAutoNegotiate. Non-Gigabit Ethernet port returns the value other(4). | 1.3.6.1.4.1.1991.1.1.3.3.5.1.19 | INTEGER {disabled(0), enabled(1), negFullAuto(2), global(3), other(4)} | read-write | current |
| snSwIfInfoFlowControl OBJECT-TYPE Enable/Disbale port flow control. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIfInfoGigType OBJECT-TYPE The media type for the port. The values are: m1000BaseSX(0)....1Gbits per second fiber, with a short wavelength transceiver. m1000BaseLX(1)....1Gbits per second fiber, with a long wavelength transceiver (3km). m1000BaseLH(2)....1Gbits per second fiber, with a special wavelength transceiver (50km). m1000BaseLHA(3)....1Gbits per second fiber, with a special wavelength transceiver (70km). m1000BaseLHB(4)....1Gbits per second fiber, with a special wavelength transceiver (150km). m1000BaseTX(5)....1Gbits per second copper (100meter). m10000BaseSR(6)....10Gbits per second fiber, with a short range wavelength transceiver (100m). m10000BaseLR(7)....10Gbits per second fiber, with a long range wavelength transceiver (10km). m10000BaseER(8)....10Gbits per second fiber, with a extended range wavelength transceiver (40km). sfpCWDM1470nm80Km(9)....1Gbits per second CWDM fiber, with a wavelength 1470nm, reach 80 kms. sfpCWDM1490nm80Km(10)....1Gbits per second CWDM fiber, with a wavelength 1490nm, reach 80 kms. sfpCWDM1510nm80Km(11)....1Gbits per second CWDM fiber, with a wavelength 1510nm, reach 80 kms. sfpCWDM1530nm80Km(12)....1Gbits per second CWDM fiber, with a wavelength 1530nm, reach 80 kms. sfpCWDM1550nm80Km(13)....1Gbits per second CWDM fiber, with a wavelength 1550nm, reach 80 kms. sfpCWDM1570nm80Km(14)....1Gbits per second CWDM fiber, with a wavelength 1570nm, reach 80 kms. sfpCWDM1590nm80Km(15)....1Gbits per second CWDM fiber, with a wavelength 1590nm, reach 80 kms. sfpCWDM1610nm80Km(16)....1Gbits per second CWDM fiber, with a wavelength 1610nm, reach 80 kms. sfpCWDM1470nm100Km(17)....1Gbits per second CWDM fiber, with a wavelength 1470nm, reach 100 kms. sfpCWDM1490nm100Km(18)....1Gbits per second CWDM fiber, with a wavelength 1490nm, reach 100 kms. sfpCWDM1510nm100Km(19)....1Gbits per second CWDM fiber, with a wavelength 1510nm, reach 100 kms. sfpCWDM1530nm100Km(20)....1Gbits per second CWDM fiber, with a wavelength 1530nm, reach 100 kms. sfpCWDM1550nm100Km(21)....1Gbits per second CWDM fiber, with a wavelength 1550nm, reach 100 kms. sfpCWDM1570nm100Km(22)....1Gbits per second CWDM fiber, with a wavelength 1570nm, reach 100 kms. sfpCWDM1590nm100Km(23)....1Gbits per second CWDM fiber, with a wavelength 1590nm, reach 100 kms. sfpCWDM1610nm100Km(24)....1Gbits per second CWDM fiber, with a wavelength 1610nm, reach 100 kms. m1000BaseLHX(25)...1Gbits per second fiber, with a special wavelength transceiver (150km). m1000BaseLMC(35)...Link Media Copper. mXFP10000BaseSR(36)...10GBASE fiber, 850nm serial pluggable XFP optic (LC), target range 300m over MMF. mXFP10000BaseLR(37)...10GBASE fiber, 1310nm serial pluggable XFP optic (LC) for up to 10km over SMF. mXFP10000BaseER(38)...10GBASE fiber, 1550nm serial pluggable XFP optic (LC) for up to 40km over SMF. mXFP10000BaseSW(39)...not used. mXFP10000BaseLW(40)...not used. mXFP10000BaseEW(41)...not used mXFP10000BaseCX4(42)...10GBASE-CX4, XFP module,15m, CX4 connector. mXFP10000BaseZR(43)...1550nm serial pluggable XFP optic (LC) for up to 80km over SMF. mXFP10000BaseZRD(44)...10GBASE-ZR DWDM, XFP optic, 80km. mXFP10000BaseSRSW(46)...same as .mXFP10000BaseSR(36) mXFP10000BaseLRLW(47)...same as .mXFP10000BaseLR(37) mXFP10000BaseEREW(48)...same as mXFP10000BaseER(38). mCFP100GBaseSR10(145)... 100GbE CFP optic (MPO 2x12), SR10, for distances up to 100m over MMF. mCFP100GBaseLR4(146)... 100GbE CFP optic (SC), LR4, for distances up to 10 km over SMF. mCFP100GBaseER4(147)... 100GbE CFP optic, ER4, for distances up to 40 km over SMF. mCFP100GBase10x10g2Km(148)... 100GbE CFP optic (LC), 10x10, for distances up to 2 km over SMF. mCFP100GBase10x10g10Km(149)... 100GbE CFP optic (LC), 10x10, for distances up to 10 km over SMF. notApplicable(255)....a non-gigabit port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.21 | INTEGER {m1000BaseSX(0), m1000BaseLX(1), m1000BaseLH(2), m1000BaseLHA(3), m1000BaseLHB(4), m1000BaseTX(5), m10000BaseSR(6), m10000BaseLR(7), m10000BaseER(8), sfpCWDM1470nm80Km(9), sfpCWDM1490nm80Km(10), sfpCWDM1510nm80Km(11), sfpCWDM1530nm80Km(12), sfpCWDM1550nm80Km(13), sfpCWDM1570nm80Km(14), sfpCWDM1590nm80Km(15), sfpCWDM1610nm80Km(16), sfpCWDM1470nm100Km(17), sfpCWDM1490nm100Km(18), sfpCWDM1510nm100Km(19), sfpCWDM1530nm100Km(20), sfpCWDM1550nm100Km(21), sfpCWDM1570nm100Km(22), sfpCWDM1590nm100Km(23), sfpCWDM1610nm100Km(24), m1000BaseLHX(25), m1000BaseSX2(26), mSFP1000BaseBXU(27), mSFP1000BaseBXD(28), mSFP100BaseBX(29), mSFP100BaseBXU(30), mSFP100BaseBXD(31), mSFP100BaseFX(32), mSFP100BaseFXIR(33), mSFP100BaseFXLR(34), m1000BaseLMC(35), mXFP10000BaseSR(36), mXFP10000BaseLR(37), mXFP10000BaseER(38), mXFP10000BaseSW(39), mXFP10000BaseLW(40), mXFP10000BaseEW(41), mXFP10000BaseCX4(42), mXFP10000BaseZR(43), mXFP10000BaseZRD(44), m1000BaseC6553(45), mXFP10000BaseSRSW(46), mXFP10000BaseLRLW(47), mXFP10000BaseEREW(48), m1000BaseGBXU(127), m1000BaseGBXD(128), m1000BaseFBX(129), m1000BaseFBXU(130), m1000BaseFBXD(131), m1000BaseFX(132), m1000BaseFXIR(133), m1000BaseFXLR(134), m1000BaseXGSR(136), m1000BaseXGLR(137), m1000BaseXGER(138), m1000BaseXGSW(139), m1000BaseXGLW(140), m1000BaseXGEW(141), m1000BaseXGCX4(142), m1000BaseXGZR(143), m1000BaseXGZRD(144), mCFP100GBaseSR10(145), mCFP100GBaseLR4(146), mCFP100GBaseER4(147), mCFP100GBase10x10g2Km(148), mCFP100GBase10x10g10Km(149), notApplicable(255)} | read-only | current |
| snSwIfFastSpanPortEnable OBJECT-TYPE The enabled/disabled fast span port status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIfFastSpanUplinkEnable OBJECT-TYPE The enabled/disabled fast span uplink status of the port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.23 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIfVlanId OBJECT-TYPE The ID of a VLAN of which this port is a member. Port must be untagged. For tagged port which belongs to multiple VLANs, this object return 0 which is an invalid VLAN ID value, reading is valid only for untagged and dual mode, writing is valid for only dual mode. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.24 | INTEGER (0..4095) | read-write | current |
| snSwIfRouteOnly OBJECT-TYPE Enable/Disable L2 switching of a routing switch port. By default, the routing switch performs routing first. If routing failed, it performs switching. Enable route only instrcuts the routing switch to perform routing only. For a L2 switching only product, reading this object always return 'disabled', writing 'enabled' to this object takes no effect. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSwIfPresent OBJECT-TYPE Indicate if the port is absent or present. This object only valid for M4 module. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.26 | INTEGER {false(0), true(1)} | read-only | current |
| snSwIfGBICStatus OBJECT-TYPE Indicate if the gig port has GBICs on them. If set to GBIC(1), it means that the port is GBIC. If set to miniGBIC(2), it means that the port miniGBIC. If set to empty(3), it means that the GBIC is missing. Value other(4) means that the port not a removable gig port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.27 | INTEGER {gbic(1), miniGBIC(2), empty(3), other(4)} | read-only | current |
| snSwIfLoadInterval OBJECT-TYPE The time in seconds for which average port utilization should be carried out. The value should be incremental of 30 seconds, between the ranges specified. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.28 | INTEGER (30..300) | read-write | current |
| snSwIfStatsInFrames OBJECT-TYPE The total number of packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.29 | Counter32 | read-only | current |
| snSwIfStatsOutFrames OBJECT-TYPE The total number of packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.30 | Counter32 | read-only | current |
| snSwIfStatsAlignErrors OBJECT-TYPE dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.31 | Counter32 | read-only | current |
| snSwIfStatsFCSErrors OBJECT-TYPE dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.32 | Counter32 | read-only | current |
| snSwIfStatsMultiColliFrames OBJECT-TYPE dot3StatsMultipleCollisionFrames : A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsSingleCollisionFrames object. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.33 | Counter32 | read-only | current |
| snSwIfStatsTxColliFrames OBJECT-TYPE A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by a combination of both dot3StatsSingleCollisionFrames and dot3StatsMultipleCollisionFrames objects. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.34 | Counter32 | read-only | current |
| snSwIfStatsRxColliFrames OBJECT-TYPE A count of successfully received frames on a particular interface for which transmission is inhibited by more than one collision. This object is not specified in dot3 but it has the same functionarity as snSwIfStatsTxColliFrames. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.35 | Counter32 | read-only | current |
| snSwIfStatsFrameTooLongs OBJECT-TYPE dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.36 | Counter32 | read-only | current |
| snSwIfStatsFrameTooShorts OBJECT-TYPE A count of frames received on a particular interface that below the minimum permitted frame size. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.37 | Counter32 | read-only | current |
| snSwIfStatsInBcastFrames OBJECT-TYPE The total number of broadcast packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.38 | Counter32 | read-only | current |
| snSwIfStatsOutBcastFrames OBJECT-TYPE The total number of broadcast packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.39 | Counter32 | read-only | current |
| snSwIfStatsInMcastFrames OBJECT-TYPE The total number of multicast packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.40 | Counter32 | read-only | current |
| snSwIfStatsOutMcastFrames OBJECT-TYPE The total number of multicast packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.41 | Counter32 | read-only | current |
| snSwIfStatsInDiscard OBJECT-TYPE The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.42 | Counter32 | read-only | current |
| snSwIfStatsOutDiscard OBJECT-TYPE The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.43 | Counter32 | read-only | current |
| snSwIfStatsMacStations OBJECT-TYPE The total number of MAC Stations connected to the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.44 | Integer32 | read-only | current |
| snSwIfStatsLinkChange OBJECT-TYPE The total number of link state change of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.45 | Counter32 | read-only | current |
| snSwIfInOctets OBJECT-TYPE The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.46 | Counter64 | read-only | current |
| snSwIfOutOctets OBJECT-TYPE The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.47 | Counter64 | read-only | current |
| snSwIfStatsInBitsPerSec OBJECT-TYPE The number of bits per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.48 | Gauge32 | read-only | current |
| snSwIfStatsOutBitsPerSec OBJECT-TYPE The number of bits per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.49 | Gauge32 | read-only | current |
| snSwIfStatsInPktsPerSec OBJECT-TYPE The number of packets per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.50 | Gauge32 | read-only | current |
| snSwIfStatsOutPktsPerSec OBJECT-TYPE The number of packets per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.51 | Gauge32 | read-only | current |
| snSwIfStatsInUtilization OBJECT-TYPE The input network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.52 | INTEGER (0..10000) | read-only | current |
| snSwIfStatsOutUtilization OBJECT-TYPE The output network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.53 | INTEGER (0..10000) | read-only | current |
| snSwIfStatsInKiloBitsPerSec OBJECT-TYPE Bit rate in kilobits per second received on the 10G and faster interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.54 | Unsigned32 | read-only | current |
| snSwIfStatsOutKiloBitsPerSec OBJECT-TYPE Bit rate in kilobits per second transmitted out of the 10G and faster interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.55 | Unsigned32 | read-only | current |
| snSwIfStatsInJumboFrames OBJECT-TYPE The total number of jumbo packets received on the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.56 | Counter64 | read-only | current |
| snSwIfStatsOutJumboFrames OBJECT-TYPE The total number of jumbo packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.57 | Counter64 | read-only | current |
| snSwIfInfoMirrorMode OBJECT-TYPE Enable/disable mirror on this port. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.58 | INTEGER {disable(0), enable(1)} | read-write | current |
| snSwIfMacLearningDisable OBJECT-TYPE The status of MAC learning feature on an ethernet port. For POS port, Get operation will return the default value and Set operation will return an error. | 1.3.6.1.4.1.1991.1.1.3.3.5.1.59 | TruthValue | read-write | current |
| snIfOpticalMonitoringInfoTable OBJECT-TYPE This table lists the instrumented parameters of all optical interfaces. | 1.3.6.1.4.1.1991.1.1.3.3.6 | not-accessible | current | |
| snIfOpticalMonitoringInfoEntry OBJECT-TYPE Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table. | 1.3.6.1.4.1.1991.1.1.3.3.6.1 | not-accessible | current | |
| snIfOpticalMonitoringTemperature OBJECT-TYPE This object holds the value of the transmitter laser diode temperature for the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning. For 100G LR4 and LR10 optic, this returns the average temperature for all lanes. | 1.3.6.1.4.1.1991.1.1.3.3.6.1.1 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalMonitoringTxPower OBJECT-TYPE This object holds the value of the transmitter optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G LR4 and LR10 optic, this returns the aggregated Tx Power for all lanes. | 1.3.6.1.4.1.1991.1.1.3.3.6.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalMonitoringRxPower OBJECT-TYPE This object holds the value of the receiver optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G LR4 and LR10 optic, this returns the aggregated Rx Power for all lanes. | 1.3.6.1.4.1.1991.1.1.3.3.6.1.3 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalMonitoringTxBiasCurrent OBJECT-TYPE Tx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm. For 100G LR4 and LR10 optic, this returns the aggregated Tx Bias Current for all lanes. | 1.3.6.1.4.1.1991.1.1.3.3.6.1.4 | DisplayString (SIZE(0..32)) | read-only | current |
| snInterfaceLookup2Table OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.7 | not-accessible | current | |
| snInterfaceLookup2Entry OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.7.1 | not-accessible | current | |
| snInterfaceLookup2InterfaceId OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.7.1.1 | InterfaceId2 | not-accessible | current |
| snInterfaceLookup2IfIndex OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.7.1.2 | Integer32 | read-only | current |
| snIfIndexLookup2Table OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.8 | not-accessible | current | |
| snIfIndexLookup2Entry OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.8.1 | not-accessible | current | |
| snIfIndexLookup2IfIndex OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.8.1.1 | Integer32 | not-accessible | current |
| snIfIndexLookup2InterfaceId OBJECT-TYPE | 1.3.6.1.4.1.1991.1.1.3.3.8.1.2 | InterfaceId2 | read-only | current |
| snIfMediaInfoTable OBJECT-TYPE This table lists the information of the media device (SFP/XFP/Copper) installed in the physical port. Only the ifIndices of Ethernet ports those are associated with the operational cards will be included in this table. | 1.3.6.1.4.1.1991.1.1.3.3.9 | not-accessible | current | |
| snIfMediaInfoEntry OBJECT-TYPE An entry in the Interface Media Information table. The ifIndices of ethernet interfaces will be used to index this table. | 1.3.6.1.4.1.1991.1.1.3.3.9.1 | not-accessible | current | |
| snIfMediaType OBJECT-TYPE The type of the media installed in the physical port. | 1.3.6.1.4.1.1991.1.1.3.3.9.1.1 | DisplayString (SIZE(0..128)) | read-only | current |
| snIfMediaVendorName OBJECT-TYPE The media vendor name, full name of the corporation. | 1.3.6.1.4.1.1991.1.1.3.3.9.1.2 | DisplayString (SIZE(0..128)) | read-only | current |
| snIfMediaVersion OBJECT-TYPE The media vendor product version number. | 1.3.6.1.4.1.1991.1.1.3.3.9.1.3 | DisplayString (SIZE(0..128)) | read-only | current |
| snIfMediaPartNumber OBJECT-TYPE The media vendor part number. | 1.3.6.1.4.1.1991.1.1.3.3.9.1.4 | DisplayString (SIZE(0..128)) | read-only | current |
| snIfMediaSerialNumber OBJECT-TYPE The vendor serial number of the media device. | 1.3.6.1.4.1.1991.1.1.3.3.9.1.5 | DisplayString (SIZE(0..128)) | read-only | current |
| snIfOpticalLaneMonitoringTable OBJECT-TYPE This table lists the instrumented parameters of all lanes within a 100G optic of type LR4 and LR10. LR4 has 4 lanes per optic, LR10 has 10 lanes per optic. | 1.3.6.1.4.1.1991.1.1.3.3.10 | not-accessible | current | |
| snIfOpticalLaneMonitoringEntry OBJECT-TYPE Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table. | 1.3.6.1.4.1.1991.1.1.3.3.10.1 | not-accessible | current | |
| snIfOpticalLaneMonitoringLane OBJECT-TYPE The lane number of this 100G optic. LR4 has 4, and LR10 has 10 lanes. | 1.3.6.1.4.1.1991.1.1.3.3.10.1.1 | Unsigned32 | not-accessible | current |
| snIfOpticalLaneMonitoringTemperature OBJECT-TYPE This object holds the value of the transmitter laser diode temperature for the lane in the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning. | 1.3.6.1.4.1.1991.1.1.3.3.10.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalLaneMonitoringTxPower OBJECT-TYPE This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. | 1.3.6.1.4.1.1991.1.1.3.3.10.1.3 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalLaneMonitoringRxPower OBJECT-TYPE This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. | 1.3.6.1.4.1.1991.1.1.3.3.10.1.4 | DisplayString (SIZE(0..32)) | read-only | current |
| snIfOpticalLaneMonitoringTxBiasCurrent OBJECT-TYPE Tx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm. | 1.3.6.1.4.1.1991.1.1.3.3.10.1.5 | DisplayString (SIZE(0..32)) | read-only | current |
| snFdbInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.4 | |||
| snFdbTable OBJECT-TYPE This table contains snFdb information for each station known to the system, one entry per station. | 1.3.6.1.4.1.1991.1.1.3.4.1 | not-accessible | current | |
| snFdbEntry OBJECT-TYPE Each entry represents the information of a static MAC station. | 1.3.6.1.4.1.1991.1.1.3.4.1.1 | not-accessible | current | |
| snFdbStationIndex OBJECT-TYPE The FDB Station index to the Fdb Station Table. | 1.3.6.1.4.1.1991.1.1.3.4.1.1.1 | INTEGER (1..256) | read-only | current |
| snFdbStationAddr OBJECT-TYPE The snFdbs physical address. The physical address represents a MAC Station. | 1.3.6.1.4.1.1991.1.1.3.4.1.1.2 | PhysAddress | read-write | current |
| snFdbStationPort OBJECT-TYPE Station slot/port number. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only). | 1.3.6.1.4.1.1991.1.1.3.4.1.1.3 | Integer32 | read-write | current |
| snFdbVLanId OBJECT-TYPE The Station VLan ID. | 1.3.6.1.4.1.1991.1.1.3.4.1.1.4 | INTEGER (1..65535) | read-write | current |
| snFdbStationQos OBJECT-TYPE The Stand alone stackable station Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch station Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) | 1.3.6.1.4.1.1991.1.1.3.4.1.1.5 | INTEGER {level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7)} | read-write | current |
| snFdbStationType OBJECT-TYPE The station type values are: notSupported -- a read value only : this product does not support MultiLayer Switching. host -- any MAC station. router -- a router-typed station. | 1.3.6.1.4.1.1991.1.1.3.4.1.1.6 | INTEGER {notSupported(0), host(1), router(2)} | read-write | current |
| snFdbRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.4.1.1.7 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snFdbStationIf OBJECT-TYPE Station interface index. | 1.3.6.1.4.1.1991.1.1.3.4.1.1.8 | InterfaceIndex | read-write | current |
| snPortStpInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.5 | |||
| snPortStpTable OBJECT-TYPE A specific snPortStpTable consists of a number of switch ports. This table only exists if only if snVLanByPortCfgTable exists and snVLanByPortCfgStpMode is enabled for each VLAN. | 1.3.6.1.4.1.1991.1.1.3.5.1 | not-accessible | deprecated | |
| snPortStpEntry OBJECT-TYPE An entry in the snPortStpTable indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPortStpTable requires the entired sequence of the MIB Objects in each snPortStpEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.1.3.5.1.1 | not-accessible | deprecated | |
| snPortStpVLanId OBJECT-TYPE The VLAN ID of the VLAN switch community. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.1 | INTEGER (1..65535) | read-only | deprecated |
| snPortStpPortNum OBJECT-TYPE The port number of the Switch. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only). | 1.3.6.1.4.1.1991.1.1.3.5.1.1.2 | Integer32 | read-only | deprecated |
| snPortStpPortPriority OBJECT-TYPE The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.3 | INTEGER (0..255) | read-write | deprecated |
| snPortStpPathCost OBJECT-TYPE dot1dStpPortPathCost : The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Writing value zero to this object sets path cost to a default value which automatically changes according to port speed. Reading value zero indicates an unknown path cost value because port speed cannot be determined due to speed auto sense in progress. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.4 | INTEGER (0..65535) | read-write | deprecated |
| snPortStpOperState OBJECT-TYPE By default, this mode is set to notActivated(0). notActivated(0)...the Port STP entry is not activated and not in running mode. activated(1)......the Port STP entry is activated and in running mode | 1.3.6.1.4.1.1991.1.1.3.5.1.1.5 | INTEGER {notActivated(0), activated(1)} | read-only | deprecated |
| snPortStpPortEnable OBJECT-TYPE The enabled/disabled status of the port. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.6 | INTEGER {enabled(1), disabled(2)} | not-accessible | deprecated |
| snPortStpPortForwardTransitions OBJECT-TYPE The number of times this port has transitioned from the Learning state to the Forwarding state. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.7 | Counter32 | not-accessible | deprecated |
| snPortStpPortState OBJECT-TYPE The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see dot1dStpPortEnable), this object will have a value of disabled(1). | 1.3.6.1.4.1.1991.1.1.3.5.1.1.8 | INTEGER {disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6), preforwarding(7)} | read-only | deprecated |
| snPortStpPortDesignatedCost OBJECT-TYPE The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.9 | Integer32 | read-only | deprecated |
| snPortStpPortDesignatedRoot OBJECT-TYPE The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.10 | BridgeId | read-only | deprecated |
| snPortStpPortDesignatedBridge OBJECT-TYPE The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.11 | BridgeId | read-only | deprecated |
| snPortStpPortDesignatedPort OBJECT-TYPE The Port Identifier of the port on the Designated Bridge for this port's segment. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.12 | OCTET STRING (SIZE(2)) | read-only | deprecated |
| snPortStpPortAdminRstp OBJECT-TYPE Enable or disable RSTP of a port which is a member of a VLAN. If the VLAN is not operating in RSTP, this object will return FALSE(2) and this object is not writable. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.13 | INTEGER {true(1), false(2)} | read-write | deprecated |
| snPortStpPortProtocolMigration OBJECT-TYPE When operating in RSTP (version 2) mode, writing TRUE(1) to this object forces this port to transmit RSTP BPDUs. Any other operation on this object has no effect and it always returns FALSE(2) when read. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.14 | INTEGER {true(1), false(2)} | read-write | deprecated |
| snPortStpPortAdminEdgePort OBJECT-TYPE The administrative value of the Edge Port parameter. A value of TRUE(1) indicates that this port should be assumed as an edge-port and a value of FALSE(2) indicates that this port should be assumed as a non-edge-port. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.15 | INTEGER {true(1), false(2)} | read-write | deprecated |
| snPortStpPortAdminPointToPoint OBJECT-TYPE The administrative point-to-point status of the LAN segment attached to this port. A value of TRUE(1) indicates that this port should always be treated as if it is connected to a point-to-point link. A value of FALSE(2) indicates that this port should be treated as having a shared media connection. | 1.3.6.1.4.1.1991.1.1.3.5.1.1.16 | INTEGER {true(1), false(2)} | read-write | deprecated |
| snIfStpTable OBJECT-TYPE A specific snIfStpTable consists of a number of switch ports. This table only exists if only if snVLanByPortCfgTable exists and snVLanByPortCfgStpMode is enabled for each VLAN. | 1.3.6.1.4.1.1991.1.1.3.5.2 | not-accessible | current | |
| snIfStpEntry OBJECT-TYPE An entry in the snIfStpTable indicates the configuration on a specified port. A SNMP SET PDU for a row of the snIfStpTable requires the entired sequence of the MIB Objects in each snIfStpEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.1.3.5.2.1 | not-accessible | current | |
| snIfStpVLanId OBJECT-TYPE The VLAN ID of the VLAN switch community. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.1 | INTEGER (1..65535) | read-only | current |
| snIfStpPortNum OBJECT-TYPE The port number of the Switch. It has the ifIndex value. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.2 | InterfaceIndex | read-only | current |
| snIfStpPortPriority OBJECT-TYPE The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.3 | INTEGER (0..255) | read-write | current |
| snIfStpCfgPathCost OBJECT-TYPE dot1dStpPortPathCost : The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Writing value zero to this object sets path cost to a default value which automatically changes according to port speed. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.4 | INTEGER (0..200000000) | read-write | current |
| snIfStpOperState OBJECT-TYPE By default, this mode is set to notActivated(0). notActivated(0)...the Port STP entry is not activated and not in running mode. activated(1)......the Port STP entry is activated and in running mode | 1.3.6.1.4.1.1991.1.1.3.5.2.1.5 | INTEGER {notActivated(0), activated(1)} | read-only | current |
| snIfStpPortState OBJECT-TYPE The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see dot1dStpPortEnable), this object will have a value of disabled(1). | 1.3.6.1.4.1.1991.1.1.3.5.2.1.8 | INTEGER {disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6), preforwarding(7)} | read-only | current |
| snIfStpPortDesignatedCost OBJECT-TYPE The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.9 | Integer32 | read-only | current |
| snIfStpPortDesignatedRoot OBJECT-TYPE The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.10 | BridgeId | read-only | current |
| snIfStpPortDesignatedBridge OBJECT-TYPE The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.11 | BridgeId | read-only | current |
| snIfStpPortDesignatedPort OBJECT-TYPE The Port Identifier of the port on the Designated Bridge for this port's segment. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.12 | OCTET STRING (SIZE(2)) | read-only | current |
| snIfStpPortAdminRstp OBJECT-TYPE Enable or disable RSTP of a port which is a member of a VLAN. If the VLAN is not operating in RSTP, this object will return FALSE(2) and this object is not writable. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.13 | TruthValue | read-write | current |
| snIfStpPortProtocolMigration OBJECT-TYPE When operating in RSTP (version 2) mode, writing TRUE(1) to this object forces this port to transmit RSTP BPDUs. Any other operation on this object has no effect and it always returns FALSE(2) when read. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.14 | TruthValue | read-write | current |
| snIfStpPortAdminEdgePort OBJECT-TYPE The administrative value of the Edge Port parameter. A value of TRUE(1) indicates that this port should be assumed as an edge-port and a value of FALSE(2) indicates that this port should be assumed as a non-edge-port. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.15 | TruthValue | read-write | current |
| snIfStpPortAdminPointToPoint OBJECT-TYPE The administrative point-to-point status of the LAN segment attached to this port. A value of TRUE(1) indicates that this port should always be treated as if it is connected to a point-to-point link. A value of FALSE(2) indicates that this port should be treated as having a shared media connection. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.16 | TruthValue | read-write | current |
| snIfStpOperPathCost OBJECT-TYPE dot1dStpPortPathCost : The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Reading value zero indicates an unknown path cost value because port speed cannot be determined due to speed auto sense in progress or port link is down. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.17 | INTEGER (0..200000000) | read-only | current |
| snIfStpPortRole OBJECT-TYPE STP/RSTP port role. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.18 | INTEGER {unknown(0), alternate(1), root(2), designated(3), backupRole(4), disabledRole(5)} | read-only | current |
| snIfStpBPDUTransmitted OBJECT-TYPE STP/RSTP bridge protocol unit transmitted counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.19 | Counter32 | read-only | current |
| snIfStpBPDUReceived OBJECT-TYPE STP/RSTP bridge protocol unit received counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.20 | Counter32 | read-only | current |
| snIfRstpConfigBPDUReceived OBJECT-TYPE RSTP configuration bridge protocol unit received counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.21 | Counter32 | read-only | current |
| snIfRstpTCNBPDUReceived OBJECT-TYPE RSTP topology change notification bridge protocol unit received counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.22 | Counter32 | read-only | current |
| snIfRstpConfigBPDUTransmitted OBJECT-TYPE RSTP configuration bridge protocol unit transmitted counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.23 | Counter32 | read-only | current |
| snIfRstpTCNBPDUTransmitted OBJECT-TYPE RSTP topology change notification bridge protocol unit transmitted counter. | 1.3.6.1.4.1.1991.1.1.3.5.2.1.24 | Counter32 | read-only | current |
| snTrunkInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.6 | |||
| snTrunkTable OBJECT-TYPE A specific snTrunkTable consists of a number of Trunk port-mask. | 1.3.6.1.4.1.1991.1.1.3.6.1 | not-accessible | current | |
| snTrunkEntry OBJECT-TYPE An entry in the snTrunkTable indicates the configuration on a specified Trunk port membership. | 1.3.6.1.4.1.1991.1.1.3.6.1.1 | not-accessible | current | |
| snTrunkIndex OBJECT-TYPE The number of the trunk entries can be configured. This can be 32*<slots> for Jetcore, and 16*<slots> for Ironcore. | 1.3.6.1.4.1.1991.1.1.3.6.1.1.1 | Integer32 | read-only | current |
| snTrunkPortMask OBJECT-TYPE Trunk membership of the Switch. | 1.3.6.1.4.1.1991.1.1.3.6.1.1.2 | PortMask | read-write | current |
| snTrunkType OBJECT-TYPE The trunk connection type which specifies what device the trunk ports are connected to. | 1.3.6.1.4.1.1991.1.1.3.6.1.1.3 | INTEGER {switch(1), server(2)} | read-write | current |
| snMSTrunkTable OBJECT-TYPE A table contains the configuration of port members of multi-slot trunk groups. | 1.3.6.1.4.1.1991.1.1.3.6.2 | not-accessible | current | |
| snMSTrunkEntry OBJECT-TYPE An entry of the snMSTrunkTable. | 1.3.6.1.4.1.1991.1.1.3.6.2.1 | not-accessible | current | |
| snMSTrunkPortIndex OBJECT-TYPE The primary port of a trunk group. For module with Gig ports, primary port is port 1, 3, 5, 7. For module with 10/100 ports, primary port is port 1, 5, 9, 13, 17, 21. | 1.3.6.1.4.1.1991.1.1.3.6.2.1.1 | Integer32 | read-only | current |
| snMSTrunkPortList OBJECT-TYPE A list of port indices which are the port membership of a trunk group. Each port index is a 16-bit integer in big endian order. The first port index must be the primary port index. | 1.3.6.1.4.1.1991.1.1.3.6.2.1.2 | OCTET STRING | read-write | current |
| snMSTrunkType OBJECT-TYPE The trunk connection type which specifies what device the trunk ports are connected to. | 1.3.6.1.4.1.1991.1.1.3.6.2.1.3 | INTEGER {switch(1), server(2)} | read-write | current |
| snMSTrunkRowStatus OBJECT-TYPE To create or delete a table entry. | 1.3.6.1.4.1.1991.1.1.3.6.2.1.4 | INTEGER {invalid(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snMSTrunkIfTable OBJECT-TYPE A table contains the configuration of port members of multi-slot trunk groups. | 1.3.6.1.4.1.1991.1.1.3.6.3 | not-accessible | current | |
| snMSTrunkIfEntry OBJECT-TYPE An entry of the snMSTrunkIfTable. | 1.3.6.1.4.1.1991.1.1.3.6.3.1 | not-accessible | current | |
| snMSTrunkIfIndex OBJECT-TYPE The primary port(IfIndex) of a trunk group. For module with Gig ports, primary port is port 1, 3, 5, 7. For module with 10/100 ports, primary port is port 1, 5, 9, 13, 17, 21. | 1.3.6.1.4.1.1991.1.1.3.6.3.1.1 | Integer32 | read-only | current |
| snMSTrunkIfList OBJECT-TYPE A list of interface indices which are the port membership of a trunk group. Each interface index is a 16-bit integer in big endian order. The first interface/port index must be the primary port(ifIndex) index. | 1.3.6.1.4.1.1991.1.1.3.6.3.1.2 | OCTET STRING | read-write | current |
| snMSTrunkIfType OBJECT-TYPE The trunk connection type which specifies what device the trunk ports are connected to. | 1.3.6.1.4.1.1991.1.1.3.6.3.1.3 | INTEGER {switch(1), server(2)} | read-write | current |
| snMSTrunkIfRowStatus OBJECT-TYPE To create or delete a table entry. | 1.3.6.1.4.1.1991.1.1.3.6.3.1.4 | INTEGER {invalid(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snSwSummary OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.7 | |||
| snSwSummaryMode OBJECT-TYPE The Switch Group Configuration Summary is configured either enabled or disabled and the default is disabled mode. enabled(1)...........activate Switch Configuration Summary. disabled(0)..........no Switch Configuration Summary. | 1.3.6.1.4.1.1991.1.1.3.7.1 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snDhcpGatewayListInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.8 | |||
| snDhcpGatewayListTable OBJECT-TYPE A table of DHCP gateway list of addresses. | 1.3.6.1.4.1.1991.1.1.3.8.1 | not-accessible | current | |
| snDhcpGatewayListEntry OBJECT-TYPE An entry in the IP Port Address table. | 1.3.6.1.4.1.1991.1.1.3.8.1.1 | not-accessible | current | |
| snDhcpGatewayListId OBJECT-TYPE The ID for a DHCP gateway list entry. | 1.3.6.1.4.1.1991.1.1.3.8.1.1.1 | INTEGER (1..32) | read-only | current |
| snDhcpGatewayListAddrList OBJECT-TYPE The DHCP gateway address list for each DHCP gateway list ID. This list contains 1 to 8 IP addresses represented by octet string. | 1.3.6.1.4.1.1991.1.1.3.8.1.1.2 | OCTET STRING (SIZE(4..32)) | read-write | current |
| snDhcpGatewayListRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row or modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.8.1.1.3 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snDnsInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.9 | |||
| snDnsDomainName OBJECT-TYPE DNS Domain Name string. | 1.3.6.1.4.1.1991.1.1.3.9.1 | DisplayString (SIZE(0..80)) | read-write | current |
| snDnsGatewayIpAddrList OBJECT-TYPE The DNS Gateway IP address list. This list contains 4 IP addresses represented by octet string. | 1.3.6.1.4.1.1991.1.1.3.9.2 | OCTET STRING (SIZE(16)) | read-write | current |
| snMacFilter OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.10 | |||
| snMacFilterTable OBJECT-TYPE MAC filter table. | 1.3.6.1.4.1.1991.1.1.3.10.1 | not-accessible | current | |
| snMacFilterEntry OBJECT-TYPE An entry in the MAC filter table. | 1.3.6.1.4.1.1991.1.1.3.10.1.1 | not-accessible | current | |
| snMacFilterIndex OBJECT-TYPE The table index for a filter entry. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.1 | Integer32 | read-only | current |
| snMacFilterAction OBJECT-TYPE Action to take if the Mac packet match with this filter. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.2 | INTEGER {deny(0), permit(1)} | read-write | current |
| snMacFilterSourceMac OBJECT-TYPE Source MAC address. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.3 | MacAddress | read-write | current |
| snMacFilterSourceMask OBJECT-TYPE Source MAC subnet mask. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.4 | MacAddress | read-write | current |
| snMacFilterDestMac OBJECT-TYPE Destination MAC address. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.5 | MacAddress | read-write | current |
| snMacFilterDestMask OBJECT-TYPE Destination MAC subnet mask. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.6 | MacAddress | read-write | current |
| snMacFilterOperator OBJECT-TYPE Type of comparison to perform. | 1.3.6.1.4.1.1991.1.1.3.10.1.1.7 | INTEGER {equal(0), notEqual(1), less(2), greater(3)} | read-write | current |
| snMacFilterFrameType OBJECT-TYPE Frame Type: ethernet-type, LLC and SNAP types | 1.3.6.1.4.1.1991.1.1.3.10.1.1.8 | INTEGER {notUsed(0), ethernet(1), llc(2), snap(3)} | read-write | current |
| snMacFilterFrameTypeNum OBJECT-TYPE Frame Type Number. 0 means NA | 1.3.6.1.4.1.1991.1.1.3.10.1.1.9 | INTEGER (0..65535) | read-write | current |
| snMacFilterRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.10.1.1.10 | INTEGER {invalid(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snMacFilterPortAccessTable OBJECT-TYPE MAC Filter port access table. | 1.3.6.1.4.1.1991.1.1.3.10.2 | not-accessible | deprecated | |
| snMacFilterPortAccessEntry OBJECT-TYPE An entry in the MAC Filter Port access table. | 1.3.6.1.4.1.1991.1.1.3.10.2.1 | not-accessible | deprecated | |
| snMacFilterPortAccessPortIndex OBJECT-TYPE The port index. For FastIron/NetIron products, port index value is from 1 to 42 For BigIron products, port index is an encoded number: The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. For virtual router interface, slot number is 15, port number is the virtual router port from 1 to 60. Therefore, port index value for BigIron is from 257 to 3900. | 1.3.6.1.4.1.1991.1.1.3.10.2.1.1 | INTEGER (1..3900) | read-only | deprecated |
| snMacFilterPortAccessFilters OBJECT-TYPE 1st octet correspond to 1st filter number and so on. | 1.3.6.1.4.1.1991.1.1.3.10.2.1.2 | OCTET STRING | read-write | deprecated |
| snMacFilterPortAccessRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.10.2.1.3 | INTEGER {invalid(1), valid(2), delete(3), create(4)} | read-write | deprecated |
| snMacFilterIfAccessTable OBJECT-TYPE MAC Filter port access table. | 1.3.6.1.4.1.1991.1.1.3.10.3 | not-accessible | current | |
| snMacFilterIfAccessEntry OBJECT-TYPE An entry in the MAC Filter Port access table. | 1.3.6.1.4.1.1991.1.1.3.10.3.1 | not-accessible | current | |
| snMacFilterIfAccessPortIndex OBJECT-TYPE The port/interface index. | 1.3.6.1.4.1.1991.1.1.3.10.3.1.1 | InterfaceIndex | read-only | current |
| snMacFilterIfAccessFilters OBJECT-TYPE 1st octet correspond to 1st filter number and so on. | 1.3.6.1.4.1.1991.1.1.3.10.3.1.2 | OCTET STRING | read-write | current |
| snMacFilterIfAccessRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.10.3.1.3 | INTEGER {invalid(1), valid(2), delete(3), create(4)} | read-write | current |
| snNTP OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.11 | |||
| snNTPGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.11.1 | |||
| snNTPPollInterval OBJECT-TYPE Interval specifies how often to poll the NTP server. Each unit is one second. This object is not supported in NI devices from R5.3 | 1.3.6.1.4.1.1991.1.1.3.11.1.1 | INTEGER (1..65535) | read-write | current |
| snNTPTimeZone OBJECT-TYPE Time zone. | 1.3.6.1.4.1.1991.1.1.3.11.1.2 | INTEGER {alaska(0), aleutian(1), arizona(2), central(3), eastIndiana(4), eastern(5), hawaii(6), michigan(7), mountain(8), pacific(9), samoa(10), gmtPlus1200(11), gmtPlus1100(12), gmtPlus1000(13), gmtPlus0900(14), gmtPlus0800(15), gmtPlus0700(16), gmtPlus0600(17), gmtPlus0500(18), gmtPlus0400(19), gmtPlus0300(20), gmtPlus0200(21), gmtPlus0100(22), gmt(23), gmtMinus0100(24), gmtMinus0200(25), gmtMinus0300(26), gmtMinus0400(27), gmtMinus0500(28), gmtMinus0600(29), gmtMinus0700(30), gmtMinus0800(31), gmtMinus0900(32), gmtMinus1000(33), gmtMinus1100(34), gmtMinus1200(35), gmtPlus1130(36), gmtPlus1030(37), gmtPlus0930(38), gmtPlus0630(39), gmtPlus0530(40), gmtPlus0430(41), gmtPlus0330(42), gmtMinus0330(43), gmtMinus0830(44), gmtMinus0930(45)} | read-write | current |
| snNTPSummerTimeEnable OBJECT-TYPE Enable/Disable daylight saving time. This enables daylight saving time for time/date starting 02:00:00 of first Sunday in April and ending 02:00:00 of last Sunday in October every year. | 1.3.6.1.4.1.1991.1.1.3.11.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snNTPSystemClock OBJECT-TYPE System clock, in the following format: octet 0: seconds after the minute [0-60] octet 1: minutes after the hour [0-59] octet 2: hours since midnight [0-23] octet 3: day of the month [1-31] octet 4: months since January [0-11] octet 5: years since 1900 octet 6: days since Sunday [0-6] Setting this object requires valid value in octets 0 to 5, and zero in octet 6. System clock can be disabled by setting zero to all octets. | 1.3.6.1.4.1.1991.1.1.3.11.1.4 | OCTET STRING (SIZE(7)) | read-write | current |
| snNTPSync OBJECT-TYPE Initiate time synchronization to the NTP servers. For set operation, only 'synchronize(2)' is accepted. For get operation, always return 'other(1)'. This object is not supported in NI devices from R5.3 | 1.3.6.1.4.1.1991.1.1.3.11.1.5 | INTEGER {other(1), synchronize(2)} | read-write | current |
| snNTPServerTable OBJECT-TYPE NTP (Network Time Protocol) server table. | 1.3.6.1.4.1.1991.1.1.3.11.2 | not-accessible | current | |
| snNTPServerEntry OBJECT-TYPE An entry in the NTP server table. | 1.3.6.1.4.1.1991.1.1.3.11.2.1 | not-accessible | current | |
| snNTPServerIp OBJECT-TYPE NTP server IP address. | 1.3.6.1.4.1.1991.1.1.3.11.2.1.1 | IpAddress | read-only | current |
| snNTPServerVersion OBJECT-TYPE NTP server version. | 1.3.6.1.4.1.1991.1.1.3.11.2.1.2 | INTEGER (1..4) | read-write | current |
| snNTPServerRowStatus OBJECT-TYPE To create or delete a NTP server table entry. | 1.3.6.1.4.1.1991.1.1.3.11.2.1.3 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snRadius OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.12 | |||
| snRadiusGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.12.1 | |||
| snRadiusSNMPAccess OBJECT-TYPE Indicate whether Radius group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Radius group MIB objects return 'general error'. | 1.3.6.1.4.1.1991.1.1.3.12.1.1 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| snRadiusEnableTelnetAuth OBJECT-TYPE Enable/Disable telnet authentication specified by 'snRadiusLoginMethod'. | 1.3.6.1.4.1.1991.1.1.3.12.1.2 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snRadiusRetransmit OBJECT-TYPE The number of authentication query retransmissions to the Radius server. | 1.3.6.1.4.1.1991.1.1.3.12.1.3 | INTEGER (0..5) | read-write | current |
| snRadiusTimeOut OBJECT-TYPE Interval specifies how long to wait for authentication reply from the Radius server, each unit is one second. | 1.3.6.1.4.1.1991.1.1.3.12.1.4 | INTEGER (1..60) | read-write | current |
| snRadiusDeadTime OBJECT-TYPE Interval specifies Radius server dead time, each unit is one minute. | 1.3.6.1.4.1.1991.1.1.3.12.1.5 | INTEGER (1..5) | read-write | current |
| snRadiusKey OBJECT-TYPE Authentication key displayed as encrypted text. Write operation can only be done if the SET request uses SNMPv3 with data encrypted using privacy key. FastIron and NetIron platforms support keysize upto 64 characters. | 1.3.6.1.4.1.1991.1.1.3.12.1.6 | DisplayString | read-write | current |
| snRadiusLoginMethod OBJECT-TYPE A sequence of authentication methods. Each octet represents a method to authenticate the user login process. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods. | 1.3.6.1.4.1.1991.1.1.3.12.1.7 | OCTET STRING (SIZE(0..7)) | read-write | current |
| snRadiusEnableMethod OBJECT-TYPE A sequence of authentication methods. Each octet represents a method to authenticate the user entering priviledge mode of the command line interface. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods. | 1.3.6.1.4.1.1991.1.1.3.12.1.8 | OCTET STRING (SIZE(0..7)) | read-write | current |
| snRadiusWebServerMethod OBJECT-TYPE A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the web-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods. | 1.3.6.1.4.1.1991.1.1.3.12.1.9 | OCTET STRING (SIZE(0..7)) | read-write | current |
| snRadiusSNMPServerMethod OBJECT-TYPE A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the snmp-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods. | 1.3.6.1.4.1.1991.1.1.3.12.1.10 | OCTET STRING (SIZE(0..7)) | read-write | current |
| snRadiusServerTable OBJECT-TYPE Radius server table. | 1.3.6.1.4.1.1991.1.1.3.12.2 | not-accessible | current | |
| snRadiusServerEntry OBJECT-TYPE An entry in the Radius server table. | 1.3.6.1.4.1.1991.1.1.3.12.2.1 | not-accessible | current | |
| snRadiusServerIp OBJECT-TYPE Radius server IP address. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.1 | IpAddress | read-only | current |
| snRadiusServerAuthPort OBJECT-TYPE Authentication UDP port number. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.2 | Integer32 | read-write | current |
| snRadiusServerAcctPort OBJECT-TYPE Account UDP port number. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.3 | Integer32 | read-write | current |
| snRadiusServerRowStatus OBJECT-TYPE To create or delete a Radius server table entry. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.4 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snRadiusServerRowKey OBJECT-TYPE Authentication key displayed as encrypted text. FastIron and NetIron platforms support keysize upto 64 characters. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.5 | DisplayString | read-write | current |
| snRadiusServerUsage OBJECT-TYPE To allow this server to be dedicated for a particular AAA activity. | 1.3.6.1.4.1.1991.1.1.3.12.2.1.6 | INTEGER {default(1), authenticationOnly(2), authorizationOnly(3), accountingOnly(4)} | read-write | current |
| snTacacs OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.13 | |||
| snTacacsGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.13.1 | |||
| snTacacsRetransmit OBJECT-TYPE The number of authentication query retransmissions to the Tacacs server. | 1.3.6.1.4.1.1991.1.1.3.13.1.1 | INTEGER (0..5) | read-write | current |
| snTacacsTimeOut OBJECT-TYPE Interval specifies how long to wait for authentication reply from the Tacacs server, each unit is one second. | 1.3.6.1.4.1.1991.1.1.3.13.1.2 | INTEGER (1..15) | read-write | current |
| snTacacsDeadTime OBJECT-TYPE Interval specifies Tacacs server dead time, each unit is one minute. | 1.3.6.1.4.1.1991.1.1.3.13.1.3 | INTEGER (1..5) | read-write | current |
| snTacacsKey OBJECT-TYPE Authentication key displayed as encrypted text. Write operation can only be done if the SET request uses SNMPv3 with data encrypted using privacy key. FastIron and NetIron platforms support keysize upto 64 characters. | 1.3.6.1.4.1.1991.1.1.3.13.1.4 | DisplayString | read-write | current |
| snTacacsSNMPAccess OBJECT-TYPE Indicate whether Tacacs group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Tacacs group MIB objects return 'general error'. | 1.3.6.1.4.1.1991.1.1.3.13.1.5 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| snTacacsServerTable OBJECT-TYPE Tacacs server table. | 1.3.6.1.4.1.1991.1.1.3.13.2 | not-accessible | current | |
| snTacacsServerEntry OBJECT-TYPE An entry in the Tacacs server table. | 1.3.6.1.4.1.1991.1.1.3.13.2.1 | not-accessible | current | |
| snTacacsServerIp OBJECT-TYPE Tacacs server IP address. | 1.3.6.1.4.1.1991.1.1.3.13.2.1.1 | IpAddress | read-only | current |
| snTacacsServerAuthPort OBJECT-TYPE Authentication UDP port number. | 1.3.6.1.4.1.1991.1.1.3.13.2.1.2 | Integer32 | read-write | current |
| snTacacsServerRowStatus OBJECT-TYPE To create or delete a Tacacs server table entry. | 1.3.6.1.4.1.1991.1.1.3.13.2.1.3 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snTacacsServerRowKey OBJECT-TYPE Authentication key displayed as encrypted text. Write operation can only be done if the SET request uses SNMPv3 with data encrypted using privacy key. FastIron and NetIron platforms support keysize upto 64 characters. | 1.3.6.1.4.1.1991.1.1.3.13.2.1.4 | DisplayString | read-write | current |
| snTacacsServerUsage OBJECT-TYPE To allow this server to be dedicated for a particular AAA activity. | 1.3.6.1.4.1.1991.1.1.3.13.2.1.5 | INTEGER {default(1), authenticationOnly(2), authorizationOnly(3), accountingOnly(4)} | read-write | current |
| snQos OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.14 | |||
| snQosProfileTable OBJECT-TYPE A table contains the configuration of qos profile groups. | 1.3.6.1.4.1.1991.1.1.3.14.1 | not-accessible | current | |
| snQosProfileEntry OBJECT-TYPE An entry of the snQosProfileTable. | 1.3.6.1.4.1.1991.1.1.3.14.1.1 | not-accessible | current | |
| snQosProfileIndex OBJECT-TYPE The table index of QOS Profile. | 1.3.6.1.4.1.1991.1.1.3.14.1.1.1 | INTEGER (1..8) | read-only | current |
| snQosProfileName OBJECT-TYPE Qos Profile Name string. | 1.3.6.1.4.1.1991.1.1.3.14.1.1.2 | DisplayString (SIZE(0..32)) | read-write | current |
| snQosProfileRequestedBandwidth OBJECT-TYPE Qos Profile Requested Bandwidth. | 1.3.6.1.4.1.1991.1.1.3.14.1.1.3 | INTEGER (0..100) | read-write | current |
| snQosProfileCalculatedBandwidth OBJECT-TYPE Qos Profile Calculated Bandwidth. | 1.3.6.1.4.1.1991.1.1.3.14.1.1.4 | INTEGER (0..100) | read-only | current |
| snQosBindTable OBJECT-TYPE A table contains the configuration of 802.1p to qos profile binding groups. | 1.3.6.1.4.1.1991.1.1.3.14.2 | not-accessible | current | |
| snQosBindEntry OBJECT-TYPE An entry of the snQosBindTable. | 1.3.6.1.4.1.1991.1.1.3.14.2.1 | not-accessible | current | |
| snQosBindIndex OBJECT-TYPE The table index of QOS Bind. | 1.3.6.1.4.1.1991.1.1.3.14.2.1.1 | INTEGER (1..8) | read-only | current |
| snQosBindPriority OBJECT-TYPE QOS bind priority. | 1.3.6.1.4.1.1991.1.1.3.14.2.1.2 | Integer32 | read-only | current |
| snQosBindProfileIndex OBJECT-TYPE QOS Bind Profile Index. This is pointer to the index of snQosProfile Table. | 1.3.6.1.4.1.1991.1.1.3.14.2.1.3 | INTEGER (1..8) | read-write | current |
| snDosAttack OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.14.3 | |||
| snDosAttackGlobal OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.14.3.1 | |||
| snDosAttackICMPDropCount OBJECT-TYPE ICMP drop counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.1.1 | Counter32 | read-only | current |
| snDosAttackICMPBlockCount OBJECT-TYPE ICMP block counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.1.2 | Counter32 | read-only | current |
| snDosAttackSYNDropCount OBJECT-TYPE SYN drop counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.1.3 | Counter32 | read-only | current |
| snDosAttackSYNBlockCount OBJECT-TYPE SYN block counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.1.4 | Counter32 | read-only | current |
| snDosAttackPortTable OBJECT-TYPE Denial of service attack port table. | 1.3.6.1.4.1.1991.1.1.3.14.3.2 | not-accessible | current | |
| snDosAttackPortEntry OBJECT-TYPE An entry of the denial of service attack port table. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1 | not-accessible | current | |
| snDosAttackPort OBJECT-TYPE ifIndex value of a port. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1.1 | Integer32 | read-only | current |
| snDosAttackPortICMPDropCount OBJECT-TYPE ICMP drop counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1.2 | Counter32 | read-only | current |
| snDosAttackPortICMPBlockCount OBJECT-TYPE ICMP block counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1.3 | Counter32 | read-only | current |
| snDosAttackPortSYNDropCount OBJECT-TYPE SYN drop counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1.4 | Counter32 | read-only | current |
| snDosAttackPortSYNBlockCount OBJECT-TYPE SYN block counter. | 1.3.6.1.4.1.1991.1.1.3.14.3.2.1.5 | Counter32 | read-only | current |
| snAAA OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.15 | |||
| snAuthentication OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.15.1 | |||
| snAuthorization OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.15.2 | |||
| snAuthorizationCommandMethods OBJECT-TYPE A sequence of authorization methods. Each octet represents a method to authorize the user command. Each octet has the following value: radius(2) - authorize by requesting radius server tacplus(5) - authorize by requesting tacplus server none(6) - skip authorization Setting a zero length octet string invalidates all previous authorization methods. | 1.3.6.1.4.1.1991.1.1.3.15.2.1 | OCTET STRING (SIZE(0..3)) | read-write | current |
| snAuthorizationCommandLevel OBJECT-TYPE Commands, which are equal to and less than the specified command level here needs to be authorized. Possible enumeration values: 0 - Privilege level 0 4 - Privilege level 4 5 - Privilege level 5. | 1.3.6.1.4.1.1991.1.1.3.15.2.2 | INTEGER {level0(0), level4(4), level5(5)} | read-write | current |
| snAuthorizationExec OBJECT-TYPE A sequence of exec authorization methods. Each octet represents a method for telnet or SSH login authorization. Each octet has the following enumeration value: radius(2) - send exec authorization request to radius server tacplus(5) - send exec authorization request to tacplus server none(6) - no exec authorization Setting a zero length octet string invalidates all authorization methods. | 1.3.6.1.4.1.1991.1.1.3.15.2.3 | OCTET STRING (SIZE(0..3)) | read-write | current |
| snAccounting OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.15.3 | |||
| snAccountingCommandMethods OBJECT-TYPE A sequence of accounting methods. Each octet represents a method to account for the user command. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods. | 1.3.6.1.4.1.1991.1.1.3.15.3.1 | OCTET STRING (SIZE(0..3)) | read-write | current |
| snAccountingCommandLevel OBJECT-TYPE Commands, which are equal to and less than the specified command level here will be accounted. Possible enumeration values: level0 - Privilege level 0 level4 - Privilege level 4 level5 - Privilege level 5. | 1.3.6.1.4.1.1991.1.1.3.15.3.2 | INTEGER {level0(0), level4(4), level5(5)} | read-write | current |
| snAccountingExec OBJECT-TYPE A sequence of accounting methods. Each octet represents a method for telnet or SSH login accounting. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods. | 1.3.6.1.4.1.1991.1.1.3.15.3.3 | OCTET STRING (SIZE(0..3)) | read-write | current |
| snAccountingSystem OBJECT-TYPE A sequence of accounting methods. Each octet represents a method to account for the system related events. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods. | 1.3.6.1.4.1.1991.1.1.3.15.3.4 | OCTET STRING (SIZE(0..3)) | read-write | current |
| snCAR OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.16 | |||
| snVLanCAR OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.17 | |||
| snNetFlow OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.18 | |||
| snNetFlowGlb OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.18.1 | |||
| snNetFlowGblEnable OBJECT-TYPE Enable/disable NetFlow export operation. | 1.3.6.1.4.1.1991.1.1.3.18.1.1 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snNetFlowGblVersion OBJECT-TYPE NetFlow export version. | 1.3.6.1.4.1.1991.1.1.3.18.1.2 | INTEGER {versionNotSet(0), version1(1), version5(5)} | read-write | current |
| snNetFlowGblProtocolDisable OBJECT-TYPE bit 0 - other, disable all protocols export except UDP and TCP bit 1 - tcp, disable TCP protocol export bit 2 - udp, disable UDP protocol export | 1.3.6.1.4.1.1991.1.1.3.18.1.3 | Integer32 | read-write | current |
| snNetFlowGblActiveTimeout OBJECT-TYPE Maximum time an active flow can be in the NetFlow cache (minutes: 1..60) | 1.3.6.1.4.1.1991.1.1.3.18.1.4 | Integer32 | read-write | current |
| snNetFlowGblInactiveTimeout OBJECT-TYPE Maximum time an inactive flow can be in the NetFlow cache (seconds: 10..600) | 1.3.6.1.4.1.1991.1.1.3.18.1.5 | Integer32 | read-write | current |
| snNetFlowCollectorTable OBJECT-TYPE A table of each NetFlow collector information. | 1.3.6.1.4.1.1991.1.1.3.18.2 | not-accessible | current | |
| snNetFlowCollectorEntry OBJECT-TYPE A row in the NetFlow collector table. | 1.3.6.1.4.1.1991.1.1.3.18.2.1 | not-accessible | current | |
| snNetFlowCollectorIndex OBJECT-TYPE The index to the NetFlow collector table. | 1.3.6.1.4.1.1991.1.1.3.18.2.1.1 | INTEGER (1..10) | read-only | current |
| snNetFlowCollectorIp OBJECT-TYPE The NetFlow collector ip address. | 1.3.6.1.4.1.1991.1.1.3.18.2.1.2 | IpAddress | read-write | current |
| snNetFlowCollectorUdpPort OBJECT-TYPE The NetFlow collector UDP port number. | 1.3.6.1.4.1.1991.1.1.3.18.2.1.3 | Integer32 | read-write | current |
| snNetFlowCollectorSourceInterface OBJECT-TYPE The ifIndex value to specify source port to export NetFlow packet. Value 0 to indicate default outgoing port. | 1.3.6.1.4.1.1991.1.1.3.18.2.1.4 | InterfaceIndex | read-write | current |
| snNetFlowCollectorRowStatus OBJECT-TYPE To create or delete a NetFlow collector table entry. | 1.3.6.1.4.1.1991.1.1.3.18.2.1.5 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snNetFlowAggregationTable OBJECT-TYPE A table of each NetFlow aggregation scheme information. | 1.3.6.1.4.1.1991.1.1.3.18.3 | not-accessible | current | |
| snNetFlowAggregationEntry OBJECT-TYPE A row in the NetFlow Aggregation table. | 1.3.6.1.4.1.1991.1.1.3.18.3.1 | not-accessible | current | |
| snNetFlowAggregationIndex OBJECT-TYPE The Aggregation scheme ID | 1.3.6.1.4.1.1991.1.1.3.18.3.1.1 | INTEGER {as(1), protocolPort(2), destPrefix(3), sourcePrefix(4), prefix(5)} | read-only | current |
| snNetFlowAggregationIp OBJECT-TYPE The NetFlow aggregation collector ip address. | 1.3.6.1.4.1.1991.1.1.3.18.3.1.2 | IpAddress | read-write | current |
| snNetFlowAggregationUdpPort OBJECT-TYPE The NetFlow aggregation collector UDP port number. | 1.3.6.1.4.1.1991.1.1.3.18.3.1.3 | Integer32 | read-write | current |
| snNetFlowAggregationSourceInterface OBJECT-TYPE The ifIndex value to specify source port to export NetFlow aggregation packet. Value 0 to indicate default outgoing port. | 1.3.6.1.4.1.1991.1.1.3.18.3.1.4 | InterfaceIndex | read-write | current |
| snNetFlowAggregationNumberOfCacheEntries OBJECT-TYPE Number of cache entries for aggregation scheme | 1.3.6.1.4.1.1991.1.1.3.18.3.1.5 | Integer32 | read-write | current |
| snNetFlowAggregationActiveTimeout OBJECT-TYPE Maximum time an active flow can be in the aggregation cache | 1.3.6.1.4.1.1991.1.1.3.18.3.1.6 | Integer32 | read-write | current |
| snNetFlowAggregationInactiveTimeout OBJECT-TYPE Maximum time an inactive flow can be in the aggregation cache | 1.3.6.1.4.1.1991.1.1.3.18.3.1.7 | Integer32 | read-write | current |
| snNetFlowAggregationEnable OBJECT-TYPE Enable/disable NetFlow aggregation for this aggregation scheme. | 1.3.6.1.4.1.1991.1.1.3.18.3.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snNetFlowAggregationRowStatus OBJECT-TYPE To create or delete a NetFlow collector table entry. | 1.3.6.1.4.1.1991.1.1.3.18.3.1.9 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snNetFlowIfTable OBJECT-TYPE A list of interface entries. The number of entries is given by the value of ifNumber. | 1.3.6.1.4.1.1991.1.1.3.18.4 | not-accessible | current | |
| snNetFlowIfEntry OBJECT-TYPE Entry containing the type of switching performed on that interface. | 1.3.6.1.4.1.1991.1.1.3.18.4.1 | not-accessible | current | |
| snNetFlowIfIndex OBJECT-TYPE A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. | 1.3.6.1.4.1.1991.1.1.3.18.4.1.1 | InterfaceIndex | read-only | current |
| snNetFlowIfFlowSwitching OBJECT-TYPE To enable/disable flow switching in a particular interface: disable (0) - no flow switching enable (1) - flow switching | 1.3.6.1.4.1.1991.1.1.3.18.4.1.2 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| snSFlow OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.19 | |||
| snSFlowGlb OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.19.1 | |||
| snSflowCollectorTable OBJECT-TYPE Table of all but first sFlow collectors. The first collector can be configured using sFlowTable in RFC 3176. The RFC cannot be used to configure more than one sFlow collectors. This table has been created to fill this gap. | 1.3.6.1.4.1.1991.1.1.3.19.2 | not-accessible | current | |
| snSflowCollectorEntry OBJECT-TYPE A row in the sFlow collector table. | 1.3.6.1.4.1.1991.1.1.3.19.2.1 | not-accessible | current | |
| snSflowCollectorIndex OBJECT-TYPE The index to the sFlow collector table. | 1.3.6.1.4.1.1991.1.1.3.19.2.1.1 | Integer32 | read-only | current |
| snSflowCollectorIP OBJECT-TYPE The sFlow collector ip address. | 1.3.6.1.4.1.1991.1.1.3.19.2.1.2 | IpAddress | read-write | current |
| snSflowCollectorUDPPort OBJECT-TYPE The sFlow collector UDP port number. | 1.3.6.1.4.1.1991.1.1.3.19.2.1.3 | Integer32 | read-write | current |
| snSflowCollectorRowStatus OBJECT-TYPE To create, update or delete a SFlow collector table entry. If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.19.2.1.4 | INTEGER {noSuch(0), other(1), valid(2), delete(3), create(4), modify(5)} | read-write | current |
| snFDP OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20 | |||
| snFdpMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20.1 | |||
| snFdpInterface OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20.1.1 | |||
| snFdpInterfaceTable OBJECT-TYPE Status of FDP on the device's interfaces. | 1.3.6.1.4.1.1991.1.1.3.20.1.1.1 | not-accessible | current | |
| snFdpInterfaceEntry OBJECT-TYPE An entry in the snFdpInterfaceTable, having the status of FDP on an interface. | 1.3.6.1.4.1.1991.1.1.3.20.1.1.1.1 | not-accessible | current | |
| snFdpInterfaceIfIndex OBJECT-TYPE ifIndex value of the local interface. | 1.3.6.1.4.1.1991.1.1.3.20.1.1.1.1.1 | InterfaceIndex | not-accessible | current |
| snFdpInterfaceFdpEnable OBJECT-TYPE The flag, whether the Foundry Discovery Protocol is currently running on this interface. It has no effect when FDP is disabled (snFdpGlobalRun = FALSE). | 1.3.6.1.4.1.1991.1.1.3.20.1.1.1.1.2 | INTEGER {false(0), true(1)} | read-write | current |
| snFdpInterfaceCdpEnable OBJECT-TYPE The flag, whether the Cisco Discovery Protocol is currently running on this interface. It has no effect when CDP is disabled (snCdpGlobalRun = FALSE). | 1.3.6.1.4.1.1991.1.1.3.20.1.1.1.1.3 | INTEGER {false(0), true(1)} | read-write | current |
| snFdpCache OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20.1.2 | |||
| snFdpCacheTable OBJECT-TYPE The table for the cached information obtained via receiving FDP/CDP messages. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1 | not-accessible | current | |
| snFdpCacheEntry OBJECT-TYPE An entry in the snFdpCacheTable, having the information received via FDP/CDP on one interface from one device. Entries appear when a FDP/CDP advertisement is received from a neighbor device. Entries disappear when FDP/CDP is disabled on the interface, or globally. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1 | not-accessible | current | |
| snFdpCacheIfIndex OBJECT-TYPE ifIndex value of the local interface. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.1 | InterfaceIndex | not-accessible | current |
| snFdpCacheDeviceIndex OBJECT-TYPE Identification of a device, which sent FDP/CDP messages | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.2 | Integer32 | not-accessible | current |
| snFdpCacheDeviceId OBJECT-TYPE The Device-ID string as reported in the most recent FDP/CDP message. The zero-length string indicates no Device-ID field (TLV) was reported in the most recent FDP/CDP message. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.3 | DisplayString | read-only | current |
| snFdpCacheAddressType OBJECT-TYPE An indication of the type of address contained in the corresponding instance of snFdpCacheAddress. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.4 | INTEGER {ip(1), ipx(2), appletalk(3)} | read-only | current |
| snFdpCacheAddress OBJECT-TYPE The (first) network-layer address of the device as reported in the most recent FDP/CDP message in the following format: IP address: 4 octets, ip(1) IPX address: 10 octets, ipx(2) First 4-octet as the network number Second 6-octet as the host number Appletalk address: 3 octets, appletalk(3) First 2-octet as the network number Second 1-octet as the host number | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.5 | OCTET STRING | read-only | current |
| snFdpCacheVersion OBJECT-TYPE Version string as reported in the most recent FDP/CDP message. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.6 | DisplayString | read-only | current |
| snFdpCacheDevicePort OBJECT-TYPE The Port-ID string as reported in the most recent FDP/CDP message. This will typically be the value of the ifName object (e.g., Ethernet0). The zero-length string indicates no Port-ID field (TLV) was reported in the most recent FDP/CDP message. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.7 | DisplayString | read-only | current |
| snFdpCachePlatform OBJECT-TYPE The Device's Hardware Platform as reported in the most recent FDP/CDP message. The zero-length string indicates that no Platform field (TLV) was reported in the most recent FDP/CDP message. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.8 | DisplayString | read-only | current |
| snFdpCacheCapabilities OBJECT-TYPE The Device's Functional Capabilities as reported in the most recent FDP/CDP message. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.9 | DisplayString | read-only | current |
| snFdpCacheVendorId OBJECT-TYPE Indicates the entry received by either FDP or CDP. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.10 | INTEGER {fdp(1), cdp(2)} | read-only | current |
| snFdpCacheIsAggregateVlan OBJECT-TYPE Neighbor device is in aggregated-vlan. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.11 | INTEGER {false(0), true(1)} | read-only | current |
| snFdpCacheTagType OBJECT-TYPE Neighbor device tag-type. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.12 | Integer32 | read-only | current |
| snFdpCachePortVlanMask OBJECT-TYPE Neighbor device port VLAN masks in 512-byte octet string. | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.13 | OCTET STRING | read-only | current |
| snFdpCachePortTagMode OBJECT-TYPE Neighbor device port tag mode | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.14 | INTEGER {untagged(1), tagged(2), dual(3)} | read-only | current |
| snFdpCacheDefaultTrafficeVlanIdForDualMode OBJECT-TYPE Default traffic vlan id for neighbor device dual-mode port | 1.3.6.1.4.1.1991.1.1.3.20.1.2.1.1.15 | Integer32 | read-only | current |
| snFdpGlobal OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20.1.3 | |||
| snFdpGlobalRun OBJECT-TYPE The flag, whether the Foundry Discovery Protocol is currently running. FDP entries in snFdpCacheTable are deleted when FDP is disabled. | 1.3.6.1.4.1.1991.1.1.3.20.1.3.1 | INTEGER {false(0), true(1)} | read-write | current |
| snFdpGlobalMessageInterval OBJECT-TYPE The interval at which FDP messages are to be generated. The default value is 60 seconds. | 1.3.6.1.4.1.1991.1.1.3.20.1.3.2 | INTEGER (5..900) | read-write | current |
| snFdpGlobalHoldTime OBJECT-TYPE The time for the receiving device holds FDP message. The default value is 180 seconds. | 1.3.6.1.4.1.1991.1.1.3.20.1.3.3 | INTEGER (10..255) | read-write | current |
| snFdpGlobalCdpRun OBJECT-TYPE An indication of whether the Cisco Discovery Protocol is currently running. CDP entries in snFdpCacheTable are deleted when CDP is disabled. | 1.3.6.1.4.1.1991.1.1.3.20.1.3.4 | INTEGER {false(0), true(1)} | read-write | current |
| snFdpCachedAddr OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.20.1.4 | |||
| snFdpCachedAddressTable OBJECT-TYPE Cached address table from receiving FDP/CDP messages. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1 | not-accessible | current | |
| snFdpCachedAddressEntry OBJECT-TYPE An entry (conceptual row) in the snFdpCacheAddressTable, containing one cached address from FDP/CDP messages. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1 | not-accessible | current | |
| snFdpCachedAddrIfIndex OBJECT-TYPE The ifIndex value of the local interface. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1.1 | InterfaceIndex | not-accessible | current |
| snFdpCachedAddrDeviceIndex OBJECT-TYPE A unique vlaue for each device from which FDP/CDP messages are being received. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1.2 | Integer32 | not-accessible | current |
| snFdpCachedAddrDeviceAddrEntryIndex OBJECT-TYPE A unique vlaue for address entry in device from which FDP/CDP messages are being received. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1.3 | Integer32 | not-accessible | current |
| snFdpCachedAddrType OBJECT-TYPE An indication of the type of address contained in the corresponding instance of snFdpCacheAddrValue. | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1.4 | INTEGER {ip(1), ipx(2), appletalk(3)} | read-only | current |
| snFdpCachedAddrValue OBJECT-TYPE The network-layer address of the device SNMP-agent as reported in the most recent FDP/CDP message in the following format: IP address: 4 octets, ip(1) IPX address: 10 octets, ipx(2) First 4-octet as the network number Second 6-octet as the host number Appletalk address: 3 octets, appletalk(3) First 2-octet as the network number Second 1-octet as the host number | 1.3.6.1.4.1.1991.1.1.3.20.1.4.1.1.5 | OCTET STRING | read-only | current |
| snVsrp OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.21 | |||
| snArpInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.22 | |||
| snWireless OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.23 | |||
| snMac OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.24 | |||
| snMacSecurity OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.24.1 | |||
| snPortMacSecurity OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.24.1.1 | |||
| snPortMacSecurityTable OBJECT-TYPE Status of port MAC security on the device's interfaces. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1 | not-accessible | current | |
| snPortMacSecurityEntry OBJECT-TYPE An entry in the snPortMacSecurityTable | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1 | not-accessible | current | |
| snPortMacSecurityIfIndex OBJECT-TYPE ifIndex value of the local Ethernet interface on which MAC security is configured. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.1 | Unsigned32 | read-only | current |
| snPortMacSecurityResource OBJECT-TYPE The MAC address was secured using local or shared resources. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.2 | INTEGER {local(1), shared(2)} | read-only | current |
| snPortMacSecurityQueryIndex OBJECT-TYPE Entry index within the given resource of local Ethernet interface on which MAC security is configured. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.3 | Unsigned32 | read-only | current |
| snPortMacSecurityMAC OBJECT-TYPE The secure MAC address for this interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.4 | MacAddress | read-only | current |
| snPortMacSecurityAgeLeft OBJECT-TYPE The number of minutes the MAC address will remain secure before being aged out. 0 means no aging. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.5 | Unsigned32 | read-only | current |
| snPortMacSecurityShutdownStatus OBJECT-TYPE Interface up/down status. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.6 | INTEGER {up(1), down(2)} | read-only | current |
| snPortMacSecurityShutdownTimeLeft OBJECT-TYPE If snPortMacSecurityShutdownStatus is up(1), this value will be 0. If snPortMacSecurityShutdownStatus is down(2), this gives the number of seconds before this interface is enabled again. In the later case, 0 means interface is permanently down. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.7 | Unsigned32 | read-only | current |
| snPortMacSecurityVlanId OBJECT-TYPE The vlan membership of this interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.1.1.8 | Unsigned32 (1..65535) | read-only | current |
| snPortMacSecurityModuleStatTable OBJECT-TYPE Port MAC security statistics on each module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2 | not-accessible | current | |
| snPortMacSecurityModuleStatEntry OBJECT-TYPE An entry in the snPortMacSecurityModuleStatTable | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1 | not-accessible | current | |
| snPortMacSecurityModuleStatSlotNum OBJECT-TYPE The slot number of the port security device module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1.1 | Integer32 | read-only | current |
| snPortMacSecurityModuleStatTotalSecurityPorts OBJECT-TYPE The totol number of Ethernet interfaces on which MAC security is configured in this module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1.2 | Unsigned32 | read-only | current |
| snPortMacSecurityModuleStatTotalMACs OBJECT-TYPE The totol number of port MAC security MAC addresses are learned or configured in this module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1.3 | Unsigned32 | read-only | current |
| snPortMacSecurityModuleStatViolationCounts OBJECT-TYPE The totol number of counts of violation are collected in this module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1.4 | Unsigned32 | read-only | current |
| snPortMacSecurityModuleStatTotalShutdownPorts OBJECT-TYPE The totol number of Ethernet interfaces are shutted down due to security violation in this module. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.2.1.5 | Unsigned32 | read-only | current |
| snPortMacSecurityIntfContentTable OBJECT-TYPE Port MAC security statistics on each Ethernet Interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3 | not-accessible | current | |
| snPortMacSecurityIntfContentEntry OBJECT-TYPE An entry in the snPortMacSecurityIntfContentTable | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1 | not-accessible | current | |
| snPortMacSecurityIntfContentIfIndex OBJECT-TYPE In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 2863. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.1 | InterfaceIndex | not-accessible | current |
| snPortMacSecurityIntfContentSecurity OBJECT-TYPE Port security for this interface can be either disabled or enabled. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.2 | INTEGER {disable(0), enable(1)} | read-write | current |
| snPortMacSecurityIntfContentViolationType OBJECT-TYPE Port security violation type for this interface is shutdown or restrict. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.3 | INTEGER {shutdown(0), restrict(1)} | read-write | current |
| snPortMacSecurityIntfContentShutdownTime OBJECT-TYPE If snPortMacSecurityIntfContentViolationType is shutdown(1), this value gives the number of seconds this interface is shut down when violation occurs. In the shutdown(1) case, 0 means interface is permanently down. If snPortMacSecurityIntfContentViolationType is restrict(2), this value will be always 0. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.4 | Unsigned32 (0..1440) | read-write | current |
| snPortMacSecurityIntfContentShutdownTimeLeft OBJECT-TYPE If snPortMacSecurityIntfContentViolationType is shutdown(1), whether this interface has been shut down due to a security violation and the value gives the number of seconds before this interface is enabled again. If snPortMacSecurityIntfContentViolationType is restrict(2), this value will be always 0. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.5 | Unsigned32 | read-only | current |
| snPortMacSecurityIntfContentAgeOutTime OBJECT-TYPE The amount of time, in minutes, MAC addresses learned on this interface will remain secure. It allows configurable values 0-1440. 0 means no aging permanently. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.6 | Unsigned32 (0..1440) | read-write | current |
| snPortMacSecurityIntfContentMaxLockedMacAllowed OBJECT-TYPE Maximum number of security MAC addresses can be locked to this interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.7 | Unsigned32 | read-write | current |
| snPortMacSecurityIntfContentTotalMACs OBJECT-TYPE The totol number of port MAC security MAC addresses are locked in this interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.8 | Unsigned32 | read-only | current |
| snPortMacSecurityIntfContentViolationCounts OBJECT-TYPE The totol number of counts of violation are collected in this interface. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.3.1.9 | Unsigned32 | read-only | current |
| snPortMacSecurityIntfMacTable OBJECT-TYPE Status of port MAC security on the device's interfaces. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4 | not-accessible | current | |
| snPortMacSecurityIntfMacEntry OBJECT-TYPE An entry in the snPortMacSecurityIntfMacTable | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4.1 | not-accessible | current | |
| snPortMacSecurityIntfMacIfIndex OBJECT-TYPE ifIndex value of the local Ethernet interface on which MAC security is configured. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4.1.1 | Integer32 | read-only | current |
| snPortMacSecurityIntfMacAddress OBJECT-TYPE The secure MAC address for this local Ethernet interface on which the secure MAC Address is configured and/or learned. The maximum number of the secure MAC Addresses is restricted by the snPortMacSecurityIntfContentMaxLockedMacAllowed. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4.1.2 | MacAddress | read-only | current |
| snPortMacSecurityIntfMacVlanId OBJECT-TYPE The vlan membership of this interface, zero means don't care. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4.1.3 | Unsigned32 (0..65535) | read-write | current |
| snPortMacSecurityIntfMacRowStatus OBJECT-TYPE This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid | 1.3.6.1.4.1.1991.1.1.3.24.1.1.4.1.4 | INTEGER {other(1), valid(2), delete(3), create(4)} | read-write | current |
| snPortMacSecurityAutosaveMacTable OBJECT-TYPE Autosave MAC addresses of port MAC security on the device's interfaces. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5 | not-accessible | current | |
| snPortMacSecurityAutosaveMacEntry OBJECT-TYPE An entry in the snPortMacSecurityAutosaveMacTable | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5.1 | not-accessible | current | |
| snPortMacSecurityAutosaveMacIfIndex OBJECT-TYPE ifIndex value of the local Ethernet interface on which MAC security is configured. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5.1.1 | Integer32 | read-only | current |
| snPortMacSecurityAutosaveMacResource OBJECT-TYPE The MAC address was autosaved using local or shared resources. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5.1.2 | INTEGER {local(1), shared(2)} | read-only | current |
| snPortMacSecurityAutosaveMacQueryIndex OBJECT-TYPE Entry index within the given resource of local Ethernet interface on which MAC security is autosaved. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5.1.3 | Unsigned32 | read-only | current |
| snPortMacSecurityAutosaveMacAddress OBJECT-TYPE The secure MAC address for this local Ethernet interface on which the secure MAC Address is autosaved. | 1.3.6.1.4.1.1991.1.1.3.24.1.1.5.1.4 | MacAddress | read-only | current |
| snPortMacGlobalSecurity OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.24.1.2 | |||
| snPortMacGlobalSecurityFeature OBJECT-TYPE Port security for this device can be either disabled or enabled. | 1.3.6.1.4.1.1991.1.1.3.24.1.2.1 | INTEGER {disable(0), enable(1)} | read-write | current |
| snPortMacGlobalSecurityAgeOutTime OBJECT-TYPE The amount of time, in minutes, MAC addresses learned on this device will remain secure. It allows configurable values in the range of 0-1440. 0 means no aging permanently. | 1.3.6.1.4.1.1991.1.1.3.24.1.2.2 | Unsigned32 (0..1440) | read-write | current |
| snPortMacGlobalSecurityAutosave OBJECT-TYPE The port security autosave value for this device. It allows configurable values 0 and also in the range of 15-1440. The value 0 means no autosave. | 1.3.6.1.4.1.1991.1.1.3.24.1.2.3 | Unsigned32 | read-write | current |
| snPortMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.25 | |||
| snPortMonitorTable OBJECT-TYPE Status of port monitoring on the device's interfaces. | 1.3.6.1.4.1.1991.1.1.3.25.1 | not-accessible | current | |
| snPortMonitorEntry OBJECT-TYPE An entry in the snPortMonitorTable | 1.3.6.1.4.1.1991.1.1.3.25.1.1 | not-accessible | current | |
| snPortMonitorIfIndex OBJECT-TYPE ifIndex value of the local interface on which monitoring is configuerd. | 1.3.6.1.4.1.1991.1.1.3.25.1.1.1 | InterfaceIndex | not-accessible | current |
| snPortMonitorMirrorList OBJECT-TYPE Lists the monitoring configuration of this port. The value is a space delimited sequence of ifIndex of mirror port and monitor mode. The values for mode can be - 0 - off, 1 - input, 2 - output, 3 - both Eg. '65 2 66 1' means send the output traffic to port 2/1 and input traffic to port 2/2. To turn off a mirror use monitor mode of 0 (off) in the list. | 1.3.6.1.4.1.1991.1.1.3.25.1.1.2 | DisplayString | read-write | current |
| snSSH OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.26 | |||
| snSSL OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.27 | |||
| snMacAuth OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.28 | |||
| snMetroRing OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.29 | |||
| snStacking OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.31 | |||
| fdryMacVlanMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.32 | |||
| fdryLinkAggregationGroupMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.33 | |||
| fdryDns2MIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.34 | |||
| fdryDaiMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.35 | |||
| fdryDhcpSnoopMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.36 | |||
| fdryIpSrcGuardMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.1.3.37 |