MIBs Depot

FOUNDRY-SN-NOTIFICATION-MIB

Registered at
1.3.6.1.4.1.1991.0
Last updated
2010-06-02 00:00
Organization
Brocade Communications Systems, Inc.
Revisions
2010-06-02 00:00, 2009-09-30 00:00
Namespace
extreme
Source file
FOUNDRY-SN-NOTIFICATION-MIB
Digest
sha256:7cce7b56b9d6a1a35802afa06707269b7a2e71587007933b92eec33c812e7284

Description

This MIB module describes proprietery SNMP Trap information of Brocade Communications' router/switch product. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.

Contact

Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com

Imports

FromSymbols
DOT3-OAM-MIBdot3OamLoopbackStatus
FOUNDRY-SN-AGENT-MIBfdryLicenseType, snAgGblTrapMessage, snAgentBrdIndex, snAgentBrdModuleStatus, snChasFanDescription, snChasFanIndex, snChasPwrSupplyDescription, snChasPwrSupplyIndex, snChasPwrSupplyStatus, snChasUnitIndex
FOUNDRY-SN-OSPF-GROUP-MIBsnOspfConfigErrorType, snOspfExtLsdbLimit, snOspfIfStatusIpAddress, snOspfIfStatusState, snOspfLsdbAreaId, snOspfLsdbLsId, snOspfLsdbRouterId, snOspfLsdbType, snOspfNbrIpAddr, snOspfNbrRtrId, snOspfNbrState, snOspfPacketSrc, snOspfPacketType, snOspfRouterId, snOspfVirtIfStatusAreaID, snOspfVirtIfStatusNeighbor, snOspfVirtIfStatusState, snOspfVirtNbrArea, snOspfVirtNbrRtrId, snOspfVirtNbrState
FOUNDRY-SN-ROOT-MIBfoundry
FOUNDRY-SN-SW-L4-SWITCH-GROUP-MIBsnL4LinkVirtualInterface, snL4MaxSessionLimit, snL4TcpSynLimit, snL4TrapLinkName, snL4TrapRealServerCurConnections, snL4TrapRealServerIP, snL4TrapRealServerName, snL4TrapRealServerPort
FOUNDRY-SN-SWITCH-GROUP-MIBsnSwViolatorMacAddress, snSwViolatorPortNumber, snVLanByPortCfgVLanId
FOUNDRY-SN-WIRELESS-GROUP-MIBwgPnPStatus
IEEE8021-CFM-MIBdot1agCfmMaNetName, dot1agCfmMdName, dot1agCfmMepDbRMepState
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BRIDGE-MIB
DOT3-OAM-MIB
FOUNDRY-SN-AGENT-MIB
FOUNDRY-SN-NOTIFICATION-MIB
FOUNDRY-SN-OSPF-GROUP-MIB
FOUNDRY-SN-ROOT-MIB
FOUNDRY-SN-SW-L4-SWITCH-GROUP-MIB
FOUNDRY-SN-SWITCH-GROUP-MIB
FOUNDRY-SN-WIRELESS-GROUP-MIB
HCNUM-TC
IANA-ADDRESS-FAMILY-NUMBERS-MIB
IANAifType-MIB
IEEE8021-CFM-MIB
IEEE8021-TC-MIB
IF-MIB
INET-ADDRESS-MIB
LLDP-MIB
P-BRIDGE-MIB
Q-BRIDGE-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.1991.0.3snTrapOspfIfStateChangeFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.4snTrapOspfVirtIfStateChangeFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.5snOspfNbrStateChangeFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.6snOspfVirtNbrStateChangeFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.7snOspfIfConfigErrorFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.8snOspfVirtIfConfigErrorFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.9snOspfIfAuthFailureFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.10snOspfVirtIfAuthFailureFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.11snOspfIfRxBadPacketFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.12snOspfVirtIfRxBadPacketFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.13snOspfTxRetransmitFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.14ospfVirtIfTxRetransmitFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.15snOspfOriginateLsaFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.16snOspfMaxAgeLsaFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.17snOspfLsdbOverflowFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.18snOspfLsdbApproachingOverflowFOUNDRY-SN-ROUTER-TRAP-MIB
1.3.6.1.4.1.1991.0.19snTrapL4MaxSessionLimitReachedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.20snTrapL4TcpSynLimitReachedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.21snTrapL4RealServerUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.22snTrapL4RealServerDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.23snTrapL4RealServerPortUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.24snTrapL4RealServerPortDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.25snTrapL4RealServerMaxConnectionLimitReachedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.26snTrapL4BecomeStandbyFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.27snTrapL4BecomeActiveFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.28snTrapModuleInsertedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.29snTrapModuleRemovedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.30snTrapChasPwrSupplyFailedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.31snTrapChasFanFailedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.32snTrapLockedAddressViolation2FOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.33snTrapFsrpIfStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.34snTrapVrrpIfStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.35snTrapMgmtModuleRedunStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.36snTrapTemperatureWarningFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.37snTrapAccessListDenyFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.38snTrapMacFilterDenyFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.39snTrapL4GslbRemoteUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.40snTrapL4GslbRemoteDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.41snTrapL4GslbRemoteControllerUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.42snTrapL4GslbRemoteControllerDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.43snTrapL4GslbHealthCheckIpUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.44snTrapL4GslbHealthCheckIpDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.45snTrapL4GslbHealthCheckIpPortUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.46snTrapL4GslbHealthCheckIpPortDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.47snTrapL4FirewallBecomeStandbyFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.48snTrapL4FirewallBecomeActiveFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.49snTrapL4FirewallPathUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.50snTrapL4FirewallPathDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.51snTrapIcmpLocalExceedBurstFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.52snTrapIcmpTransitExceedBurstFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.53snTrapTcpLocalExceedBurstFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.54snTrapTcpTransitExceedBurstFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.55snTrapL4ContentVerificationFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.56snTrapDuplicateIpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.57snTrapMplsProblemFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.58snTrapMplsExceptionFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.59snTrapMplsAuditFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.60snTrapMplsDeveloperFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.61snTrapNoBmFreeQueueFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.62snTrapSmcDmaDropFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.63snTrapSmcBpDropFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.64snTrapBmWriteSeqDropFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.65snTrapBgpPeerUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.66snTrapBgpPeerDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.67snTrapL4RealServerResponseTimeLowerLimitFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.68snTrapL4RealServerResponseTimeUpperLimitFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.69snTrapL4TcpAttackRateExceedMaxFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.70snTrapL4TcpAttackRateExceedThresholdFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.71snTrapL4ConnectionRateExceedMaxFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.72snTrapL4ConnectionRateExceedThresholdFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.73snTrapRunningConfigChangedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.74snTrapStartupConfigChangedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.75snTrapUserLoginFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.76snTrapUserLogoutFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.77snTrapPortSecurityViolationFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.78snTrapPortSecurityShutdownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.79snTrapMrpStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.80snTrapMrpCamErrorFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.81snTrapChasPwrSupplyOKFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.82snTrapVrrpeIfStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.83snTrapVsrpIfStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.84snTrapSrcIpAddressViolationFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.85snTrapMacAuthEnableFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.86snTrapMacAuthDisableFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.87snTrapMacAuthMACAcceptedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.88snTrapMacAuthMACRejectedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.89snTrapMacAuthPortDisabledFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.110snTrapClientLoginRejectFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.111snTrapLocalUserConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.112snTrapVlanConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.113snTrapAclConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.114snTrapMacFilterConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.115snTrapSNMPConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.116snTrapSyslogConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.117snTrapPasswordConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.118snTrapServerStatusChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.119snTrapL4RealServerPortMaxConnectionLimitReachedFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.120snTrapL4LinkDownFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.121snTrapL4LinkUpFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.122snTrapPortPriorityChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.123snTrapAutoPortDisableTriggerFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.124snTrapAutoPortDisableReleaseFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.125snTrapPnPStatusChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.126snTrapWirelessIsrpPeerStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.127snTrapWirelessStationStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.128snTrapWirelessStationRoamingEventTriggeredFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.129snTrapWirelessSappStateChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.130snTrapExternalPowerConnectionStatusFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.131snTrapDot1xSecurityViolationFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.132snTrapDot1xPortLinkChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.133snTrapDot1xPortControlChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.134snTrapDot1xVlanIdChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.135snTrapDot1xFilterSetupFailureFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.136snTrapDot1xErrorFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.137snTrapPortConfigChangeFOUNDRY-SN-TRAP-MIB
1.3.6.1.4.1.1991.0.138snTrapMacAuthVlanIdChangeFOUNDRY-SN-TRAP-MIB

Notifications

NameOIDStatus
snTrapChasPwrSupply
NOTIFICATION-TYPE
The SNMP trap that is generated when a power supply fails to operate normally. The value is a packed bit string; the 2 power supplies status are encoded into 4 bits (a nibble). The following shows the meaning of each bit: (bit 0 is the least significant bit). bit position meaning ------------ ------- 4-31 reserved 3 Power Supply 2 DC (0=bad, 1=good). 2 Power Supply 1 DC (0=bad, 1=good). 1 Power Supply 2 present status (0=present, 1=not-present). 0 Power Supply 1 present status (0=present, 1=not-present).
1.3.6.1.4.1.1991.0.1current
snTrapLockedAddressViolation
NOTIFICATION-TYPE
The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port.
1.3.6.1.4.1.1991.0.2current
snTrapOspfIfStateChange
NOTIFICATION-TYPE
An ospfIfStateChange trap signifies that there has been a change in the state of a non-virtual OSPF interface. This trap should be generated when the interface state regresses (e.g., goes from Dr to Down) or progresses to a terminal state (i.e., Point-to-Point, DR Other, Dr, or Backup).
1.3.6.1.4.1.1991.0.3current
snTrapOspfVirtIfStateChange
NOTIFICATION-TYPE
An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual interface. This trap should be generated when the inter- face state regresses (e.g., goes from Point- to-Point to Down) or progresses to a terminal state (i.e., Point-to-Point).
1.3.6.1.4.1.1991.0.4current
snOspfNbrStateChange
NOTIFICATION-TYPE
An ospfNbrStateChange trap signifies that there has been a change in the state of a non- virtual OSPF neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., 2-Way or Full). When an neighbor transitions from or to Full on non-broadcast multi-access and broadcast networks, the trap should be gen- erated by the designated router. A designated router transitioning to Down will be noted by ospfIfStateChange.
1.3.6.1.4.1.1991.0.5current
snOspfVirtNbrStateChange
NOTIFICATION-TYPE
An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., Full).
1.3.6.1.4.1.1991.0.6current
snOspfIfConfigError
NOTIFICATION-TYPE
An ospfIfConfigError trap signifies that a packet has been received on a non-virtual in- terface from a router whose configuration parameters conflict with this router's confi- guration parameters. Note that the event op- tionMismatch should cause a trap only if it prevents an adjacency from forming.
1.3.6.1.4.1.1991.0.7current
snOspfVirtIfConfigError
NOTIFICATION-TYPE
An ospfConfigError trap signifies that a pack- et has been received on a virtual interface from a router whose configuration parameters conflict with this router's configuration parameters. Note that the event optionMismatch should cause a trap only if it prevents an ad- jacency from forming.
1.3.6.1.4.1.1991.0.8current
snOspfIfAuthFailure
NOTIFICATION-TYPE
An ospfIfAuthFailure trap signifies that a packet has been received on a non-virtual in- terface from a router whose authentication key or authentication type conflicts with this router's authentication key or authentication type.
1.3.6.1.4.1.1991.0.9current
snOspfVirtIfAuthFailure
NOTIFICATION-TYPE
An ospfVirtIfAuthFailure trap signifies that a packet has been received on a virtual interface from a router whose authentication key or au- thentication type conflicts with this router's authentication key or authentication type.
1.3.6.1.4.1.1991.0.10current
snOspfIfRxBadPacket
NOTIFICATION-TYPE
An ospfIfRxBadPacket trap signifies that an OSPF packet has been received on a non-virtual interface that cannot be parsed.
1.3.6.1.4.1.1991.0.11current
snOspfVirtIfRxBadPacket
NOTIFICATION-TYPE
An ospfRxBadPacket trap signifies that an OSPF packet has been received on a virtual interface that cannot be parsed.
1.3.6.1.4.1.1991.0.12current
snOspfTxRetransmit
NOTIFICATION-TYPE
An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a non- virtual interface. All packets that may be re- transmitted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry.
1.3.6.1.4.1.1991.0.13current
ospfVirtIfTxRetransmit
NOTIFICATION-TYPE
An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a virtual interface. All packets that may be retransmit- ted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry.
1.3.6.1.4.1.1991.0.14current
snOspfOriginateLsa
NOTIFICATION-TYPE
An ospfOriginateLsa trap signifies that a new LSA has been originated by this router. This trap should not be invoked for simple refreshes of LSAs (which happesn every 30 minutes), but instead will only be invoked when an LSA is (re)originated due to a topology change. Addi- tionally, this trap does not include LSAs that are being flushed because they have reached MaxAge.
1.3.6.1.4.1.1991.0.15current
snOspfMaxAgeLsa
NOTIFICATION-TYPE
An ospfMaxAgeLsa trap signifies that one of the LSA in the router's link-state database has aged to MaxAge.
1.3.6.1.4.1.1991.0.16current
snOspfLsdbOverflow
NOTIFICATION-TYPE
An ospfLsdbOverflow trap signifies that the number of LSAs in the router's link-state data- base has exceeded ospfExtLsdbLimit.
1.3.6.1.4.1.1991.0.17current
snOspfLsdbApproachingOverflow
NOTIFICATION-TYPE
An ospfLsdbApproachingOverflow trap signifies that the number of LSAs in the router's link- state database has exceeded ninety percent of ospfExtLsdbLimit.
1.3.6.1.4.1.1991.0.18current
snTrapL4MaxSessionLimitReached
NOTIFICATION-TYPE
The SNMP trap that is generated when the maximum number of connections reached.
1.3.6.1.4.1.1991.0.19current
snTrapL4TcpSynLimitReached
NOTIFICATION-TYPE
The SNMP trap that is generated when the number of TCP SYN limits reached.
1.3.6.1.4.1.1991.0.20current
snTrapL4RealServerUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the load balancing real server is up.
1.3.6.1.4.1.1991.0.21current
snTrapL4RealServerDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the load balancing real server is down.
1.3.6.1.4.1.1991.0.22current
snTrapL4RealServerPortUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the load balancing real server TCP port is up.
1.3.6.1.4.1.1991.0.23current
snTrapL4RealServerPortDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the load balancing real server TCP port is down.
1.3.6.1.4.1.1991.0.24current
snTrapL4RealServerMaxConnectionLimitReached
NOTIFICATION-TYPE
The SNMP trap that is generated when the real server reaches maximum number of connections.
1.3.6.1.4.1.1991.0.25current
snTrapL4BecomeStandby
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch changes state from active to standby.
1.3.6.1.4.1.1991.0.26current
snTrapL4BecomeActive
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch changes state from standby to active.
1.3.6.1.4.1.1991.0.27current
snTrapModuleInserted
NOTIFICATION-TYPE
The SNMP trap that is generated when a module was inserted to the chassis during system running.
1.3.6.1.4.1.1991.0.28current
snTrapModuleRemoved
NOTIFICATION-TYPE
The SNMP trap that is generated when a module was removed from the chassis during system running.
1.3.6.1.4.1.1991.0.29current
snTrapChasPwrSupplyFailed
NOTIFICATION-TYPE
The SNMP trap that is generated when a power supply operational status changed from normal to failure.
1.3.6.1.4.1.1991.0.30current
snTrapChasFanFailed
NOTIFICATION-TYPE
The SNMP trap that is generated when a fan fails to operate normally.
1.3.6.1.4.1.1991.0.31current
snTrapLockedAddressViolation2
NOTIFICATION-TYPE
The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port.
1.3.6.1.4.1.1991.0.32current
snTrapFsrpIfStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a FSRP routing device changed state from active to standby or vice-versa.
1.3.6.1.4.1.1991.0.33current
snTrapVrrpIfStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a VRRP routing device switched between states master, backup, intialized or uknown.
1.3.6.1.4.1.1991.0.34current
snTrapMgmtModuleRedunStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when the management module changes redundancy state.
1.3.6.1.4.1.1991.0.35current
snTrapTemperatureWarning
NOTIFICATION-TYPE
The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold.
1.3.6.1.4.1.1991.0.36current
snTrapAccessListDeny
NOTIFICATION-TYPE
The SNMP trap that is generated when a packet was denied by an access list.
1.3.6.1.4.1.1991.0.37current
snTrapMacFilterDeny
NOTIFICATION-TYPE
The SNMP trap that is generated when a packet was denied by a MAC address filter.
1.3.6.1.4.1.1991.0.38current
snTrapL4GslbRemoteUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the connection to the remote SI is established.
1.3.6.1.4.1.1991.0.39current
snTrapL4GslbRemoteDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the connection to the remote SI is down.
1.3.6.1.4.1.1991.0.40current
snTrapL4GslbRemoteControllerUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the connection to the GSLB SI is established.
1.3.6.1.4.1.1991.0.41current
snTrapL4GslbRemoteControllerDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the connection to the GSLB SI is down.
1.3.6.1.4.1.1991.0.42current
snTrapL4GslbHealthCheckIpUp
NOTIFICATION-TYPE
The SNMP trap that is generated when GSLB health check for an address transitions from down to active state.
1.3.6.1.4.1.1991.0.43current
snTrapL4GslbHealthCheckIpDown
NOTIFICATION-TYPE
The SNMP trap that is generated when GSLB health check for an address transitions from active to down state.
1.3.6.1.4.1.1991.0.44current
snTrapL4GslbHealthCheckIpPortUp
NOTIFICATION-TYPE
The SNMP trap that is generated when a given port for a health check address is up.
1.3.6.1.4.1.1991.0.45current
snTrapL4GslbHealthCheckIpPortDown
NOTIFICATION-TYPE
The SNMP trap that is generated when a given port for a health check address is down.
1.3.6.1.4.1.1991.0.46current
snTrapL4FirewallBecomeStandby
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch Firewall changes state from active to standby.
1.3.6.1.4.1.1991.0.47current
snTrapL4FirewallBecomeActive
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch Firewall changes state from standby to active.
1.3.6.1.4.1.1991.0.48current
snTrapL4FirewallPathUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch Firewall path is up.
1.3.6.1.4.1.1991.0.49current
snTrapL4FirewallPathDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the server load balancing switch Firewall path is down.
1.3.6.1.4.1.1991.0.50current
snTrapIcmpLocalExceedBurst
NOTIFICATION-TYPE
The SNMP trap that is generated when incoming ICMP exceeds burst-MAX.
1.3.6.1.4.1.1991.0.51current
snTrapIcmpTransitExceedBurst
NOTIFICATION-TYPE
The SNMP trap that is generated when transit ICMP exceeds burst-MAX.
1.3.6.1.4.1.1991.0.52current
snTrapTcpLocalExceedBurst
NOTIFICATION-TYPE
The SNMP trap that is generated when incoming TCP SYN exceeds burst-MAX.
1.3.6.1.4.1.1991.0.53current
snTrapTcpTransitExceedBurst
NOTIFICATION-TYPE
The SNMP trap that is generated when transit TCP exceeds burst-MAX.
1.3.6.1.4.1.1991.0.54current
snTrapL4ContentVerification
NOTIFICATION-TYPE
The SNMP trap that is generated when the HTTP match-list pattern is found.
1.3.6.1.4.1.1991.0.55current
snTrapDuplicateIp
NOTIFICATION-TYPE
Duplicate IP address detected.
1.3.6.1.4.1.1991.0.56current
snTrapMplsProblem
NOTIFICATION-TYPE
NOT IMPLEMENTED: MPLS Problem Detected.
1.3.6.1.4.1.1991.0.57obsolete
snTrapMplsException
NOTIFICATION-TYPE
NOT IMPLEMENTED: MPLS Exception Detected.
1.3.6.1.4.1.1991.0.58obsolete
snTrapMplsAudit
NOTIFICATION-TYPE
NOT IMPLEMENTED: MPLS Audit Trap.
1.3.6.1.4.1.1991.0.59obsolete
snTrapMplsDeveloper
NOTIFICATION-TYPE
NOT IMPLEMENTED: MPLS Developer Trap.
1.3.6.1.4.1.1991.0.60obsolete
snTrapNoBmFreeQueue
NOTIFICATION-TYPE
The SNMP trap that is generated when no free queue is available in buffer manager.
1.3.6.1.4.1.1991.0.61current
snTrapSmcDmaDrop
NOTIFICATION-TYPE
The SNMP trap that is generated when SMC DMA packet is dropped.
1.3.6.1.4.1.1991.0.62current
snTrapSmcBpDrop
NOTIFICATION-TYPE
The SNMP trap that is generated when SMC BackPlane packet is dropped.
1.3.6.1.4.1.1991.0.63current
snTrapBmWriteSeqDrop
NOTIFICATION-TYPE
The SNMP trap that is generated when BM write sequence packet is dropped.
1.3.6.1.4.1.1991.0.64current
snTrapBgpPeerUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the bgp peer is up.
1.3.6.1.4.1.1991.0.65current
snTrapBgpPeerDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the bgp peer is down.
1.3.6.1.4.1.1991.0.66current
snTrapL4RealServerResponseTimeLowerLimit
NOTIFICATION-TYPE
The SNMP trap that is generated when the real server average response time exceeds lower threshold.
1.3.6.1.4.1.1991.0.67current
snTrapL4RealServerResponseTimeUpperLimit
NOTIFICATION-TYPE
The SNMP trap that is generated when the real server average response time exceeds upper threshold.
1.3.6.1.4.1.1991.0.68current
snTrapL4TcpAttackRateExceedMax
NOTIFICATION-TYPE
The SNMP trap that is generated when the TCP attack rate exceeds configured maximum.
1.3.6.1.4.1.1991.0.69current
snTrapL4TcpAttackRateExceedThreshold
NOTIFICATION-TYPE
The SNMP trap that is generated when the TCP attack rate exceeds 80% of configured maximum.
1.3.6.1.4.1.1991.0.70current
snTrapL4ConnectionRateExceedMax
NOTIFICATION-TYPE
The SNMP trap that is generated when the L4 connection rate exceeds configured maximum.
1.3.6.1.4.1.1991.0.71current
snTrapL4ConnectionRateExceedThreshold
NOTIFICATION-TYPE
The SNMP trap that is generated when the L4 connection rate exceeds 80% of configured maximum
1.3.6.1.4.1.1991.0.72current
snTrapRunningConfigChanged
NOTIFICATION-TYPE
The SNMP trap that is generated when the running configuration was changed.
1.3.6.1.4.1.1991.0.73current
snTrapStartupConfigChanged
NOTIFICATION-TYPE
The SNMP trap that is generated when the startup configuration was changed.
1.3.6.1.4.1.1991.0.74current
snTrapUserLogin
NOTIFICATION-TYPE
The SNMP trap that is generated when user login.
1.3.6.1.4.1.1991.0.75current
snTrapUserLogout
NOTIFICATION-TYPE
The SNMP trap that is generated when user logout.
1.3.6.1.4.1.1991.0.76current
snTrapPortSecurityViolation
NOTIFICATION-TYPE
The SNMP trap that is generated when insecure MAC addresses are received from a port with MAC security feature enabled.
1.3.6.1.4.1.1991.0.77current
snTrapPortSecurityShutdown
NOTIFICATION-TYPE
The SNMP trap that is generated when insecure MAC addresses are received from a port caused the port to shutdown.
1.3.6.1.4.1.1991.0.78current
snTrapMrpStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a MRP switching and routing device changed state to disabled, blocking, preforwarding, forwarding, uknown.
1.3.6.1.4.1.1991.0.79current
snTrapMrpCamError
NOTIFICATION-TYPE
The SNMP trap that is generated when a MRP Cam Error occurs.
1.3.6.1.4.1.1991.0.80current
snTrapChasPwrSupplyOK
NOTIFICATION-TYPE
The SNMP trap that is generated when a power supply operational status changed from failure to normal.
1.3.6.1.4.1.1991.0.81current
snTrapVrrpeIfStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a VRRPE routing device switched between states master, backup, intialized or uknown.
1.3.6.1.4.1.1991.0.82current
snTrapVsrpIfStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a VSRP switching and routing device switched between states master, backup, intialized or uknown.
1.3.6.1.4.1.1991.0.83current
snTrapSrcIpAddressViolation
NOTIFICATION-TYPE
The SNMP trap that is generated when a rogue device spoofs source IP address for denial of service attack.
1.3.6.1.4.1.1991.0.84current
snTrapMacAuthEnable
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC-Authentication is enabled on an interface.
1.3.6.1.4.1.1991.0.85current
snTrapMacAuthDisable
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC-Authentication is disabled on an interface.
1.3.6.1.4.1.1991.0.86current
snTrapMacAuthMACAccepted
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC-Authentication is successful on an interface.
1.3.6.1.4.1.1991.0.87current
snTrapMacAuthMACRejected
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC-Authentication is failed on an interface.
1.3.6.1.4.1.1991.0.88current
snTrapMacAuthPortDisabled
NOTIFICATION-TYPE
The SNMP trap that is generated when an interface is disabled due to MAC-Authentication detecting a DOS attack on that interface.
1.3.6.1.4.1.1991.0.89current
snTrapClientLoginReject
NOTIFICATION-TYPE
The SNMP trap that is generated when a login attempt by a telnet or SSH client fails.
1.3.6.1.4.1.1991.0.110current
snTrapLocalUserConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a local user configuration is changed.
1.3.6.1.4.1.1991.0.111current
snTrapVlanConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a vlan configuration is changed.
1.3.6.1.4.1.1991.0.112current
snTrapAclConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a ACL configuration is changed.
1.3.6.1.4.1.1991.0.113current
snTrapMacFilterConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a MAC Filter configuration is changed.
1.3.6.1.4.1.1991.0.114current
snTrapSNMPConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a SNMP configuration is changed.
1.3.6.1.4.1.1991.0.115current
snTrapSyslogConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a Syslog configuration is changed.
1.3.6.1.4.1.1991.0.116current
snTrapPasswordConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when enable or line password is changed.
1.3.6.1.4.1.1991.0.117current
snTrapServerStatusChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a server is disabled or enabled.
1.3.6.1.4.1.1991.0.118current
snTrapL4RealServerPortMaxConnectionLimitReached
NOTIFICATION-TYPE
The SNMP trap that is generated when the real server's port reaches maximum number of connections.
1.3.6.1.4.1.1991.0.119current
snTrapL4LinkDown
NOTIFICATION-TYPE
The SNMP trap that is generated when the ISP link goes down.
1.3.6.1.4.1.1991.0.120current
snTrapL4LinkUp
NOTIFICATION-TYPE
The SNMP trap that is generated when the ISP link goes up.
1.3.6.1.4.1.1991.0.121current
snTrapPortPriorityChange
NOTIFICATION-TYPE
The SNMP trap that is generated when the priority of a port is changed.
1.3.6.1.4.1.1991.0.122current
snTrapAutoPortDisableTrigger
NOTIFICATION-TYPE
The SNMP trap that is generated when automatic port disable was triggered.
1.3.6.1.4.1.1991.0.123current
snTrapAutoPortDisableRelease
NOTIFICATION-TYPE
The SNMP trap that is generated when automatic port disable was released.
1.3.6.1.4.1.1991.0.124current
snTrapPnPStatusChange
NOTIFICATION-TYPE
The SNMP trap that is generated when plug-and-play status change.
1.3.6.1.4.1.1991.0.125current
snTrapWirelessIsrpPeerStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when ISRP Peer changes state.
1.3.6.1.4.1.1991.0.126current
snTrapWirelessStationStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a wireless station's state changes.
1.3.6.1.4.1.1991.0.127current
snTrapWirelessStationRoamingEventTriggered
NOTIFICATION-TYPE
The SNMP trap that is generated when we received a MOVE request from the AP
1.3.6.1.4.1.1991.0.128current
snTrapWirelessSappStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when SAPP between an AP and a FIPS changes state.
1.3.6.1.4.1.1991.0.129current
snTrapExternalPowerConnectionStatus
NOTIFICATION-TYPE
The SNMP trap that is generated when the external power supply connecting or disconnecting to a power over ethernet module.
1.3.6.1.4.1.1991.0.130current
snTrapDot1xSecurityViolation
NOTIFICATION-TYPE
The SNMP trap that is generated when a malicious mac address was detected.
1.3.6.1.4.1.1991.0.131current
snTrapDot1xPortLinkChange
NOTIFICATION-TYPE
The SNMP trap that is generated when software port link status has changed to up or down.
1.3.6.1.4.1.1991.0.132current
snTrapDot1xPortControlChange
NOTIFICATION-TYPE
The SNMP trap that is generated when software port control status has changed to authorize or unauthorize.
1.3.6.1.4.1.1991.0.133current
snTrapDot1xVlanIdChange
NOTIFICATION-TYPE
The SNMP trap that is generated when VLAN ID of a port has changed.
1.3.6.1.4.1.1991.0.134current
snTrapDot1xFilterSetupFailure
NOTIFICATION-TYPE
The SNMP trap that is generated when software failed to setup a filter to a mac address of a port.
1.3.6.1.4.1.1991.0.135current
snTrapDot1xError
NOTIFICATION-TYPE
The SNMP trap that is generated when software detected system error.
1.3.6.1.4.1.1991.0.136current
snTrapPortConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when a port configuration is changed.
1.3.6.1.4.1.1991.0.137current
snTrapMacAuthVlanIdChange
NOTIFICATION-TYPE
The SNMP trap that is generated when VLAN ID of a port has changed.
1.3.6.1.4.1.1991.0.138current
snTrapWebAuthEnabled
NOTIFICATION-TYPE
The SNMP trap that is generated when web authentication is enabled.
1.3.6.1.4.1.1991.0.139current
snTrapWebAuthDisabled
NOTIFICATION-TYPE
The SNMP trap that is generated when web authentication is disabled.
1.3.6.1.4.1.1991.0.140current
snTrapIpConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when IP system address changes.
1.3.6.1.4.1.1991.0.141current
snTrapIpv6ConfigChange
NOTIFICATION-TYPE
The SNMP trap that is generated when IPv6 system address changes.
1.3.6.1.4.1.1991.0.142current
snTrapMacAuthRadiusTimeout
NOTIFICATION-TYPE
The SNMP trap that is generated when a request from Mac-Auth to RADIUS has not been answered within the retry and time limit.
1.3.6.1.4.1.1991.0.143current
snTrapDot1xRadiusTimeout
NOTIFICATION-TYPE
The SNMP trap that is generated when a request from 802.1x to RADIUS has not been answered within the retry and time limit.
1.3.6.1.4.1.1991.0.144current
snTrapUDLDLinkDown
NOTIFICATION-TYPE
The SNMP trap that is generated when UDLD port link status has changed to down.
1.3.6.1.4.1.1991.0.145current
snTrapUDLDLinkUp
NOTIFICATION-TYPE
The SNMP trap that is generated when UDLD port link status has changed to up.
1.3.6.1.4.1.1991.0.146current
snTrapMacBasedVlanEnabled
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC based VLAN is enabled.
1.3.6.1.4.1.1991.0.147current
snTrapMacBasedVlanDisabled
NOTIFICATION-TYPE
The SNMP trap that is generated when MAC based VLAN is disabled.
1.3.6.1.4.1.1991.0.148current
snTrapChasFanNormal
NOTIFICATION-TYPE
The SNMP trap that is generated when a fan operational status changed from failure to normal.
1.3.6.1.4.1.1991.0.149current
snTrapStpRootGuardDetect
NOTIFICATION-TYPE
The SNMP trap that is generated when VLAN's Root-Guarded port received superior BPDU.
1.3.6.1.4.1.1991.0.150current
snTrapStpRootGuardExpire
NOTIFICATION-TYPE
The SNMP trap that is generated when VLAN's ports's Root-Guard expire.
1.3.6.1.4.1.1991.0.151current
snTrapStpBPDUGuardDetect
NOTIFICATION-TYPE
The SNMP trap that is generated when VLAN's BPDU-guarded port received BPDU .
1.3.6.1.4.1.1991.0.152current
snTrapMstpBPDUGuardDetect
NOTIFICATION-TYPE
The SNMP trap that is generated when BPDU-guarded port received BPDU .
1.3.6.1.4.1.1991.0.153current
snTrapErrorDisableAction
NOTIFICATION-TYPE
The SNMP trap that is generated when Interface error-disable is hit or recovery times out .
1.3.6.1.4.1.1991.0.154current
snTrapLACPLinkStateChange
NOTIFICATION-TYPE
The SNMP trap that is generated when LACP port changes its state.
1.3.6.1.4.1.1991.0.155current
snTrapOpticalMonitoringNotFoundryOptics
NOTIFICATION-TYPE
The SNMP trap that is generated if optical monitoring is enabled but optics vendor is not Foundry Networks.
1.3.6.1.4.1.1991.0.156current
snTrapOpticalMonitoringFoundryOpticsNotCapable
NOTIFICATION-TYPE
The SNMP trap that is generated if optical monitoring is enabled but the Foundry optic is not capable.
1.3.6.1.4.1.1991.0.157current
snTrapStaticMulticastMacConfigAdd
NOTIFICATION-TYPE
The SNMP trap that is generated if a new entry is added to static multicast mac configuration table. Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id>
1.3.6.1.4.1.1991.0.158current
snTrapStaticMulticastMacConfigRemove
NOTIFICATION-TYPE
The SNMP trap that is generated if an entry is removed from static multicast mac configuration table . Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id>
1.3.6.1.4.1.1991.0.159current
snTrapSTPBPDUGuardExpire
NOTIFICATION-TYPE
The SNMP notification that is generated when a port is re-enabled after being disabled due to BPDU Guard Violation. Format: STP: BPDU Guard re-enabled on VLAN <id> port <slot>/<port>
1.3.6.1.4.1.1991.0.160current
snTrapPortLoopDetection
NOTIFICATION-TYPE
The SNMP notification is generated when a port loop is detected. Format: LOOP DETECTION: VLAN <id>, port <slot>/<port> detect, putting into err-disable state
1.3.6.1.4.1.1991.0.161current
snTrapNoFreeTcamEntry
NOTIFICATION-TYPE
The SNMP trap that is generated when system is running out of TCAM spaces allocated for routing entries.
1.3.6.1.4.1.1991.0.162current
snTrapStackingMasterElected
NOTIFICATION-TYPE
The SNMP trap that is generated when a unit is elected as Master unit for the stacking system.
1.3.6.1.4.1.1991.0.163current
snTrapStackingUnitAdded
NOTIFICATION-TYPE
The SNMP trap that is generated when a unit has been added to the stacking system.
1.3.6.1.4.1.1991.0.164current
snTrapStackingUnitDeleted
NOTIFICATION-TYPE
The SNMP trap that is generated when a unit has been deleted from the stacking system.
1.3.6.1.4.1.1991.0.165current
snTrapStackingChasPwrSupplyOK
NOTIFICATION-TYPE
The SNMP trap that is generated when a power supply operational status changed from failure to normal for a stacking system.
1.3.6.1.4.1.1991.0.166current
snTrapStackingChasPwrSupplyFailed
NOTIFICATION-TYPE
The SNMP trap that is generated when a power supply operational status changed from normal to failure for a stacking system.
1.3.6.1.4.1.1991.0.167current
snTrapStackingChasFanNormal
NOTIFICATION-TYPE
The SNMP trap that is generated when a fan operational status changed from failure to normal for a stacking system
1.3.6.1.4.1.1991.0.168current
snTrapStackingChasFanFailed
NOTIFICATION-TYPE
The SNMP trap that is generated when a fan fails to operate normally for a stacking system.
1.3.6.1.4.1.1991.0.169current
snTrapStackingManagementMACChanged
NOTIFICATION-TYPE
The SNMP trap that is generated when the managemnet MAC address of a stacking system has been changed.
1.3.6.1.4.1.1991.0.170current
snTrapStackingTemperatureWarning
NOTIFICATION-TYPE
The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold for a stack sytem.
1.3.6.1.4.1.1991.0.171current
snTrapIfIndexAssignmentChanged
NOTIFICATION-TYPE
The SNMP trap that is generated when the Interface Index (IfIndex) assignment for the physical interfaces was changed.
1.3.6.1.4.1.1991.0.172current
snTrapPBRConfigChanged
NOTIFICATION-TYPE
The SNMP trap that is generated when a Policy Based Routing (PBR) routemap is bound or unbound either globally or to an interface.
1.3.6.1.4.1.1991.0.173current
snTrapChasPwrSupplyRPSAdd
NOTIFICATION-TYPE
The SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is added to the system.
1.3.6.1.4.1.1991.0.174current
snTrapChasPwrSupplyRPSRemove
NOTIFICATION-TYPE
The SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is removed from the system.
1.3.6.1.4.1.1991.0.175current
snTrapModuleStatusChange
NOTIFICATION-TYPE
The SNMP notification that is generated when a module's operational state changes. The management entity receiving the notification can identify the module and the event by referencing snChasUnitIndex, snAgentBrdIndex, snAgentBrdModuleStatus. In case of a module-down event, the varbind snAgGblTrapMessage is a text string that describes the cause. In case of module-up event, snAgGblTrapMessage is a null string.
1.3.6.1.4.1.1991.0.176current
snTrapChasHighSpeedFansNeeded
NOTIFICATION-TYPE
The SNMP trap that is generated when chassis doesn't have high speed fans for specific modules
1.3.6.1.4.1.1991.0.177current
snTrapSysmaxReverted
NOTIFICATION-TYPE
The SNMP trap that is generated when the revertible sysmax elements are reverted during the card bringup if they can not be accomodated in the available memory.
1.3.6.1.4.1.1991.0.178current
snTrapSysmaxLeftLowMem
NOTIFICATION-TYPE
The SNMP trap that is generated when its found during bootup that the configured sysmax set shall leave less than 10% available memory free.
1.3.6.1.4.1.1991.0.179current
snTrapSysMemoryLowThreshold
NOTIFICATION-TYPE
The SNMP trap that is generated when the available dynamic memory in a card is below 5% of the installed physical memory.
1.3.6.1.4.1.1991.0.180current
snTrapSysMemoryOutThreshold
NOTIFICATION-TYPE
The SNMP trap that is generated when the dynamic memory fails to be allocated in a system.
1.3.6.1.4.1.1991.0.181current
snTrapLinkOAMLinkDown
NOTIFICATION-TYPE
The SNMP trap that is generated when Link-OAM port link status has changed to down.
1.3.6.1.4.1.1991.0.182current
snTrapLinkOAMLinkUp
NOTIFICATION-TYPE
The SNMP trap that is generated when Link-OAM port link status has changed to up.
1.3.6.1.4.1.1991.0.183current
snTrapI2CAccessLog
NOTIFICATION-TYPE
The SNMP trap that is generated to provide information about state of the management module's I2C accesses.
1.3.6.1.4.1.1991.0.184current
snTrapLinkOAMLoopbackEntered
NOTIFICATION-TYPE
The SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more.
1.3.6.1.4.1.1991.0.185current
snTrapLinkOAMLoopbackCleared
NOTIFICATION-TYPE
The SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more.
1.3.6.1.4.1.1991.0.186current
snTrapLicenseAdded
NOTIFICATION-TYPE
The SNMP trap that is generated when a new license is added to the system.
1.3.6.1.4.1.1991.0.187current
snTrapLicenseRemoved
NOTIFICATION-TYPE
The SNMP trap that is generated when an existing license is removed from the system.
1.3.6.1.4.1.1991.0.188current
snTrapLicenseExpires
NOTIFICATION-TYPE
The SNMP trap that is generated when a trial license is about to expire. This trap is generated daily for last 3 days and every 2 hours on the last day of expire.
1.3.6.1.4.1.1991.0.189current
snTrapLicenseExpired
NOTIFICATION-TYPE
The SNMP trap that is generated when a trial license has expired.
1.3.6.1.4.1.1991.0.190current
snTrapUDLDCrcFailureDetected
NOTIFICATION-TYPE
The SNMP trap that is generated when UDLD detects CRC failures on PDUs received on a port
1.3.6.1.4.1.1991.0.191current
snTrapDot1agCfmRemoteMEPAgeOut
NOTIFICATION-TYPE
The SNMP trap that is generated when 802.1ag Remote MEP ages out.
1.3.6.1.4.1.1991.0.192current
snTrapDot1agCfmRemoteMEPUp
NOTIFICATION-TYPE
The SNMP trap that is generated when 802.1ag Remote MEP is up.
1.3.6.1.4.1.1991.0.193current
snTrapDot1agCfmDomainCrossConnection
NOTIFICATION-TYPE
The SNMP trap that is generated when 802.1ag domain gets cross-connected.
1.3.6.1.4.1.1991.0.194current
snTrapDot1agCfmDuplicateMEPId
NOTIFICATION-TYPE
The SNMP trap that is generated when 802.1ag Remote MEP reports a duplicate MEP Id that conflicts with local MEP Id.
1.3.6.1.4.1.1991.0.195current
snTrapStackingStandbyElected
NOTIFICATION-TYPE
The SNMP trap that is generated when a unit is elected as Standby unit for the stacking system.
1.3.6.1.4.1.1991.0.196current
snTrapMacMoveThresholdRate
NOTIFICATION-TYPE
The SNMP notification is generated when MAC movement exceeding the certain threshold for a sampling interval is detected. Format: Mac-Move threshold-rate: MAC address <mac> moved from interface <port-id> to interface <port-id> for vlan <vlan-id>, <move-count> times exceeding the threshold rate <threshold-rate> for a sampling interval <interval> seconds
1.3.6.1.4.1.1991.0.197current
snTrapMacMoveIntervalHistory
NOTIFICATION-TYPE
The SNMP notification is generated every user configured interval, summarizing the moves in the interval . Format: Mac-Move Interval-History: <#macs> macs moved in last <interval> seconds. Total number of mac moves in the interval is <#moves>
1.3.6.1.4.1.1991.0.198current
snTrapChasFanOK
NOTIFICATION-TYPE
The SNMP trap that is generated when a fan operational status changed from failure to normal or change in the fan speed due to temperature variations downwards.
1.3.6.1.4.1.1991.0.1000current
snTrapTemperatureOK
NOTIFICATION-TYPE
The SNMP trap that is generated when the actual temperature reading is below the warning temperature threshold.
1.3.6.1.4.1.1991.0.1001current
snTrapCAMOverflow
NOTIFICATION-TYPE
The SNMP trap that is generated when any CAM partition becomes full.
1.3.6.1.4.1.1991.0.1002current
snTrapOpticalMonitoringWarning
NOTIFICATION-TYPE
The SNMP trap that is generated if there is a warning during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1003current
snTrapOpticalMonitoringAlarm
NOTIFICATION-TYPE
The SNMP trap that is generated if there is an alarm during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1004current
snTrapOpticalMonitoringError
NOTIFICATION-TYPE
The SNMP trap that is generated if there is an error during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1005current
snTrapPosMonitoringWarning
NOTIFICATION-TYPE
The SNMP trap that is generated if there is a warning during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1006current
snTrapPosMonitoringAlarm
NOTIFICATION-TYPE
The SNMP trap that is generated if there is an alarm up/down during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1007current
snTrapPosMonitoringError
NOTIFICATION-TYPE
The SNMP trap that is generated if there is an error during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1008current
snTrapXfpSfpIncompatibleOptics
NOTIFICATION-TYPE
The SNMP trap that is generated if optics is incompatible with port configuration.
1.3.6.1.4.1.1991.0.1009current
snTrapTMLoggingStart
NOTIFICATION-TYPE
The SNMP trap that is generated if TM logging is started by an event trigger.
1.3.6.1.4.1.1991.0.1015current
snTrapTMLoggingStop
NOTIFICATION-TYPE
The SNMP trap that is generated if TM logging stopped due to storage full.
1.3.6.1.4.1.1991.0.1016current
snTrapTMLoggingRestart
NOTIFICATION-TYPE
The SNMP trap that is generated if TM logging restarted after user clearing the log.
1.3.6.1.4.1.1991.0.1017current
snTrapXfpSfpNotFoundryOptics
NOTIFICATION-TYPE
The SNMP trap that is generated if optics vendor is not Foundry Networks.
1.3.6.1.4.1.1991.0.1018current
snTrapTMRecoverySlotReset
NOTIFICATION-TYPE
The SNMP trap that is generated when TM recovery slot reset is triggered.
1.3.6.1.4.1.1991.0.1019current
snTrapTMEgressDataError
NOTIFICATION-TYPE
The SNMP trap that is generated when system detects egress data errors on Traffic Manager. For e.g. Fabric Monitoring : TM Egress data errors detected on LP <num>/TM <num>
1.3.6.1.4.1.1991.0.1020current
snTrapSFMLinkDown
NOTIFICATION-TYPE
The SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is down. For eg. Fabric Monitoring Link Down : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num>
1.3.6.1.4.1.1991.0.1100current
snTrapSFMLinkUp
NOTIFICATION-TYPE
The SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is up. For eg. Fabric Monitoring Link Up : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num>
1.3.6.1.4.1.1991.0.1101current
snTrapSFMAccessError
NOTIFICATION-TYPE
The SNMP trap that is generated when system fails to access a SFM Fabric Element. For e.g. Fabric Monitoring : Device access failure in SFM <num>/FE <num>
1.3.6.1.4.1.1991.0.1102current
snTrapSFMStatusChange
NOTIFICATION-TYPE
The SNMP notification that is generated when there is a change in the operational state of the Switch Fabric Module (SFM). For example, System: Health Monitoring: SFM <num> powered off due to failure detection
1.3.6.1.4.1.1991.0.1103current
snTrapLPFabricStatusChange
NOTIFICATION-TYPE
Health Monitoring: LP Fabric status change.
1.3.6.1.4.1.1991.0.1104current
snTrapChassisFanSpeedLow
NOTIFICATION-TYPE
The SNMP trap that is generated when all chassis fans change to low speed.
1.3.6.1.4.1.1991.0.1200current
snTrapChassisFanSpeedMedium
NOTIFICATION-TYPE
The SNMP trap that is generated when all chassis fans change to medium speed.
1.3.6.1.4.1.1991.0.1201current
snTrapChassisFanSpeedMedHigh
NOTIFICATION-TYPE
The SNMP trap that is generated when all chassis fans change to medium high speed.
1.3.6.1.4.1.1991.0.1202current
snTrapChassisFanSpeedHigh
NOTIFICATION-TYPE
The SNMP trap that is generated when all chassis fans change to high speed.
1.3.6.1.4.1.1991.0.1203current
snTrapFIPSModeEnable
NOTIFICATION-TYPE
The SNMP trap that is generated when FIPS mode is enabled.
1.3.6.1.4.1.1991.0.1207current
snTrapFIPSModeDisable
NOTIFICATION-TYPE
The SNMP trap that is generated when FIPS mode is disabled.
1.3.6.1.4.1.1991.0.1208current
snTrapFIPSHostZeroized
NOTIFICATION-TYPE
The SNMP trap that is generated when host keys are zeroized in FIPS mode
1.3.6.1.4.1.1991.0.1209current
snTrapFIPSSharedSecretZeroized
NOTIFICATION-TYPE
The SNMP trap that is generated when shared secret are zeroized in FIPS mode
1.3.6.1.4.1.1991.0.1210current
snTrapFIPSPOSTStatus
NOTIFICATION-TYPE
The SNMP trap that is generated after POST.
1.3.6.1.4.1.1991.0.1211current
snTrapFIPSCryptoModuleFailure
NOTIFICATION-TYPE
The SNMP trap that is generated on cryptographic module failure.
1.3.6.1.4.1.1991.0.1212current
snTrapLicense2PortNotSupported
NOTIFICATION-TYPE
The SNMP trap that is generated when a 2 port license cannot be applied due to hardware limitation.
1.3.6.1.4.1.1991.0.1213current
snTrapOpticalMonitoringOK
NOTIFICATION-TYPE
The SNMP trap that is generated when an interface transitions from an error to normal state because the alarms/warnings are below the threshold. snTrapOpticalMonitoringError would have been earlier generated when the interface transitioned to the error state. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
1.3.6.1.4.1.1991.0.1214current
snTrapSFMAccessOK
NOTIFICATION-TYPE
The SNMP trap that is generated when system can successfully access an SFM Fabric Element. snTrapSFMAccessError would have been generated when the system failed to access the FE. For e.g. Fabric Monitoring : Device SFM <num>/FE <num> is OK to access.
1.3.6.1.4.1.1991.0.1215current
snTrapUpgradeSingleCmdStart
NOTIFICATION-TYPE
The SNMP trap that is generated when the single-command package upgrade has started. This happens after a successful download and validation of manifest file and before the first image download takes place.
1.3.6.1.4.1.1991.0.1216current
snTrapUpgradeSingleCmdDone
NOTIFICATION-TYPE
The SNMP trap that is generated when the single-command package upgrade completed, or partially completed. The table brcdSwPackageLoadResultTable lists the result of the upgrade.
1.3.6.1.4.1.1991.0.1217current
snTrapAutoUpgradeStart
NOTIFICATION-TYPE
The SNMP trap that is generated when an auto-upgrade on a line card has started.
1.3.6.1.4.1.1991.0.1218current
snTrapAutoUpgradeDone
NOTIFICATION-TYPE
The SNMP trap that is generated when the auto-upgrade of interface module completed.
1.3.6.1.4.1.1991.0.1219current