FOUNDRY-SN-NOTIFICATION-MIB
- Registered at
- 1.3.6.1.4.1.1991.0
- Last updated
- 2010-06-02 00:00
- Organization
- Brocade Communications Systems, Inc.
- Revisions
- 2010-06-02 00:00, 2009-09-30 00:00
- Namespace
- extreme
- Source file
FOUNDRY-SN-NOTIFICATION-MIB- Digest
sha256:7cce7b56b9d6a1a35802afa06707269b7a2e71587007933b92eec33c812e7284
Description
This MIB module describes proprietery SNMP Trap information of Brocade Communications' router/switch product. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
Contact
Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com
Imports
| From | Symbols |
|---|---|
| DOT3-OAM-MIB | dot3OamLoopbackStatus |
| FOUNDRY-SN-AGENT-MIB | fdryLicenseType, snAgGblTrapMessage, snAgentBrdIndex, snAgentBrdModuleStatus, snChasFanDescription, snChasFanIndex, snChasPwrSupplyDescription, snChasPwrSupplyIndex, snChasPwrSupplyStatus, snChasUnitIndex |
| FOUNDRY-SN-OSPF-GROUP-MIB | snOspfConfigErrorType, snOspfExtLsdbLimit, snOspfIfStatusIpAddress, snOspfIfStatusState, snOspfLsdbAreaId, snOspfLsdbLsId, snOspfLsdbRouterId, snOspfLsdbType, snOspfNbrIpAddr, snOspfNbrRtrId, snOspfNbrState, snOspfPacketSrc, snOspfPacketType, snOspfRouterId, snOspfVirtIfStatusAreaID, snOspfVirtIfStatusNeighbor, snOspfVirtIfStatusState, snOspfVirtNbrArea, snOspfVirtNbrRtrId, snOspfVirtNbrState |
| FOUNDRY-SN-ROOT-MIB | foundry |
| FOUNDRY-SN-SW-L4-SWITCH-GROUP-MIB | snL4LinkVirtualInterface, snL4MaxSessionLimit, snL4TcpSynLimit, snL4TrapLinkName, snL4TrapRealServerCurConnections, snL4TrapRealServerIP, snL4TrapRealServerName, snL4TrapRealServerPort |
| FOUNDRY-SN-SWITCH-GROUP-MIB | snSwViolatorMacAddress, snSwViolatorPortNumber, snVLanByPortCfgVLanId |
| FOUNDRY-SN-WIRELESS-GROUP-MIB | wgPnPStatus |
| IEEE8021-CFM-MIB | dot1agCfmMaNetName, dot1agCfmMdName, dot1agCfmMepDbRMepState |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB DOT3-OAM-MIB FOUNDRY-SN-AGENT-MIB FOUNDRY-SN-NOTIFICATION-MIB FOUNDRY-SN-OSPF-GROUP-MIB FOUNDRY-SN-ROOT-MIB FOUNDRY-SN-SW-L4-SWITCH-GROUP-MIB FOUNDRY-SN-SWITCH-GROUP-MIB FOUNDRY-SN-WIRELESS-GROUP-MIB HCNUM-TC IANA-ADDRESS-FAMILY-NUMBERS-MIB IANAifType-MIB IEEE8021-CFM-MIB IEEE8021-TC-MIB IF-MIB INET-ADDRESS-MIB LLDP-MIB P-BRIDGE-MIB Q-BRIDGE-MIB RFC1158-MIB RFC1271-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC TOKEN-RING-RMON-MIB
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1991.0.3 | snTrapOspfIfStateChange | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.4 | snTrapOspfVirtIfStateChange | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.5 | snOspfNbrStateChange | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.6 | snOspfVirtNbrStateChange | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.7 | snOspfIfConfigError | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.8 | snOspfVirtIfConfigError | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.9 | snOspfIfAuthFailure | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.10 | snOspfVirtIfAuthFailure | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.11 | snOspfIfRxBadPacket | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.12 | snOspfVirtIfRxBadPacket | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.13 | snOspfTxRetransmit | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.14 | ospfVirtIfTxRetransmit | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.15 | snOspfOriginateLsa | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.16 | snOspfMaxAgeLsa | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.17 | snOspfLsdbOverflow | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.18 | snOspfLsdbApproachingOverflow | FOUNDRY-SN-ROUTER-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.19 | snTrapL4MaxSessionLimitReached | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.20 | snTrapL4TcpSynLimitReached | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.21 | snTrapL4RealServerUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.22 | snTrapL4RealServerDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.23 | snTrapL4RealServerPortUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.24 | snTrapL4RealServerPortDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.25 | snTrapL4RealServerMaxConnectionLimitReached | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.26 | snTrapL4BecomeStandby | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.27 | snTrapL4BecomeActive | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.28 | snTrapModuleInserted | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.29 | snTrapModuleRemoved | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.30 | snTrapChasPwrSupplyFailed | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.31 | snTrapChasFanFailed | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.32 | snTrapLockedAddressViolation2 | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.33 | snTrapFsrpIfStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.34 | snTrapVrrpIfStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.35 | snTrapMgmtModuleRedunStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.36 | snTrapTemperatureWarning | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.37 | snTrapAccessListDeny | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.38 | snTrapMacFilterDeny | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.39 | snTrapL4GslbRemoteUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.40 | snTrapL4GslbRemoteDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.41 | snTrapL4GslbRemoteControllerUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.42 | snTrapL4GslbRemoteControllerDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.43 | snTrapL4GslbHealthCheckIpUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.44 | snTrapL4GslbHealthCheckIpDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.45 | snTrapL4GslbHealthCheckIpPortUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.46 | snTrapL4GslbHealthCheckIpPortDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.47 | snTrapL4FirewallBecomeStandby | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.48 | snTrapL4FirewallBecomeActive | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.49 | snTrapL4FirewallPathUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.50 | snTrapL4FirewallPathDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.51 | snTrapIcmpLocalExceedBurst | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.52 | snTrapIcmpTransitExceedBurst | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.53 | snTrapTcpLocalExceedBurst | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.54 | snTrapTcpTransitExceedBurst | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.55 | snTrapL4ContentVerification | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.56 | snTrapDuplicateIp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.57 | snTrapMplsProblem | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.58 | snTrapMplsException | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.59 | snTrapMplsAudit | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.60 | snTrapMplsDeveloper | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.61 | snTrapNoBmFreeQueue | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.62 | snTrapSmcDmaDrop | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.63 | snTrapSmcBpDrop | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.64 | snTrapBmWriteSeqDrop | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.65 | snTrapBgpPeerUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.66 | snTrapBgpPeerDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.67 | snTrapL4RealServerResponseTimeLowerLimit | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.68 | snTrapL4RealServerResponseTimeUpperLimit | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.69 | snTrapL4TcpAttackRateExceedMax | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.70 | snTrapL4TcpAttackRateExceedThreshold | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.71 | snTrapL4ConnectionRateExceedMax | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.72 | snTrapL4ConnectionRateExceedThreshold | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.73 | snTrapRunningConfigChanged | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.74 | snTrapStartupConfigChanged | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.75 | snTrapUserLogin | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.76 | snTrapUserLogout | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.77 | snTrapPortSecurityViolation | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.78 | snTrapPortSecurityShutdown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.79 | snTrapMrpStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.80 | snTrapMrpCamError | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.81 | snTrapChasPwrSupplyOK | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.82 | snTrapVrrpeIfStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.83 | snTrapVsrpIfStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.84 | snTrapSrcIpAddressViolation | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.85 | snTrapMacAuthEnable | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.86 | snTrapMacAuthDisable | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.87 | snTrapMacAuthMACAccepted | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.88 | snTrapMacAuthMACRejected | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.89 | snTrapMacAuthPortDisabled | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.110 | snTrapClientLoginReject | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.111 | snTrapLocalUserConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.112 | snTrapVlanConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.113 | snTrapAclConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.114 | snTrapMacFilterConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.115 | snTrapSNMPConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.116 | snTrapSyslogConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.117 | snTrapPasswordConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.118 | snTrapServerStatusChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.119 | snTrapL4RealServerPortMaxConnectionLimitReached | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.120 | snTrapL4LinkDown | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.121 | snTrapL4LinkUp | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.122 | snTrapPortPriorityChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.123 | snTrapAutoPortDisableTrigger | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.124 | snTrapAutoPortDisableRelease | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.125 | snTrapPnPStatusChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.126 | snTrapWirelessIsrpPeerStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.127 | snTrapWirelessStationStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.128 | snTrapWirelessStationRoamingEventTriggered | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.129 | snTrapWirelessSappStateChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.130 | snTrapExternalPowerConnectionStatus | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.131 | snTrapDot1xSecurityViolation | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.132 | snTrapDot1xPortLinkChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.133 | snTrapDot1xPortControlChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.134 | snTrapDot1xVlanIdChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.135 | snTrapDot1xFilterSetupFailure | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.136 | snTrapDot1xError | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.137 | snTrapPortConfigChange | FOUNDRY-SN-TRAP-MIB |
| 1.3.6.1.4.1.1991.0.138 | snTrapMacAuthVlanIdChange | FOUNDRY-SN-TRAP-MIB |
Notifications
| Name | OID | Status |
|---|---|---|
| snTrapChasPwrSupply NOTIFICATION-TYPE The SNMP trap that is generated when a power supply fails to operate normally. The value is a packed bit string; the 2 power supplies status are encoded into 4 bits (a nibble). The following shows the meaning of each bit: (bit 0 is the least significant bit). bit position meaning ------------ ------- 4-31 reserved 3 Power Supply 2 DC (0=bad, 1=good). 2 Power Supply 1 DC (0=bad, 1=good). 1 Power Supply 2 present status (0=present, 1=not-present). 0 Power Supply 1 present status (0=present, 1=not-present). | 1.3.6.1.4.1.1991.0.1 | current |
| snTrapLockedAddressViolation NOTIFICATION-TYPE The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port. | 1.3.6.1.4.1.1991.0.2 | current |
| snTrapOspfIfStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of a non-virtual OSPF interface. This trap should be generated when the interface state regresses (e.g., goes from Dr to Down) or progresses to a terminal state (i.e., Point-to-Point, DR Other, Dr, or Backup). | 1.3.6.1.4.1.1991.0.3 | current |
| snTrapOspfVirtIfStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual interface. This trap should be generated when the inter- face state regresses (e.g., goes from Point- to-Point to Down) or progresses to a terminal state (i.e., Point-to-Point). | 1.3.6.1.4.1.1991.0.4 | current |
| snOspfNbrStateChange NOTIFICATION-TYPE An ospfNbrStateChange trap signifies that there has been a change in the state of a non- virtual OSPF neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., 2-Way or Full). When an neighbor transitions from or to Full on non-broadcast multi-access and broadcast networks, the trap should be gen- erated by the designated router. A designated router transitioning to Down will be noted by ospfIfStateChange. | 1.3.6.1.4.1.1991.0.5 | current |
| snOspfVirtNbrStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., Full). | 1.3.6.1.4.1.1991.0.6 | current |
| snOspfIfConfigError NOTIFICATION-TYPE An ospfIfConfigError trap signifies that a packet has been received on a non-virtual in- terface from a router whose configuration parameters conflict with this router's confi- guration parameters. Note that the event op- tionMismatch should cause a trap only if it prevents an adjacency from forming. | 1.3.6.1.4.1.1991.0.7 | current |
| snOspfVirtIfConfigError NOTIFICATION-TYPE An ospfConfigError trap signifies that a pack- et has been received on a virtual interface from a router whose configuration parameters conflict with this router's configuration parameters. Note that the event optionMismatch should cause a trap only if it prevents an ad- jacency from forming. | 1.3.6.1.4.1.1991.0.8 | current |
| snOspfIfAuthFailure NOTIFICATION-TYPE An ospfIfAuthFailure trap signifies that a packet has been received on a non-virtual in- terface from a router whose authentication key or authentication type conflicts with this router's authentication key or authentication type. | 1.3.6.1.4.1.1991.0.9 | current |
| snOspfVirtIfAuthFailure NOTIFICATION-TYPE An ospfVirtIfAuthFailure trap signifies that a packet has been received on a virtual interface from a router whose authentication key or au- thentication type conflicts with this router's authentication key or authentication type. | 1.3.6.1.4.1.1991.0.10 | current |
| snOspfIfRxBadPacket NOTIFICATION-TYPE An ospfIfRxBadPacket trap signifies that an OSPF packet has been received on a non-virtual interface that cannot be parsed. | 1.3.6.1.4.1.1991.0.11 | current |
| snOspfVirtIfRxBadPacket NOTIFICATION-TYPE An ospfRxBadPacket trap signifies that an OSPF packet has been received on a virtual interface that cannot be parsed. | 1.3.6.1.4.1.1991.0.12 | current |
| snOspfTxRetransmit NOTIFICATION-TYPE An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a non- virtual interface. All packets that may be re- transmitted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. | 1.3.6.1.4.1.1991.0.13 | current |
| ospfVirtIfTxRetransmit NOTIFICATION-TYPE An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a virtual interface. All packets that may be retransmit- ted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. | 1.3.6.1.4.1.1991.0.14 | current |
| snOspfOriginateLsa NOTIFICATION-TYPE An ospfOriginateLsa trap signifies that a new LSA has been originated by this router. This trap should not be invoked for simple refreshes of LSAs (which happesn every 30 minutes), but instead will only be invoked when an LSA is (re)originated due to a topology change. Addi- tionally, this trap does not include LSAs that are being flushed because they have reached MaxAge. | 1.3.6.1.4.1.1991.0.15 | current |
| snOspfMaxAgeLsa NOTIFICATION-TYPE An ospfMaxAgeLsa trap signifies that one of the LSA in the router's link-state database has aged to MaxAge. | 1.3.6.1.4.1.1991.0.16 | current |
| snOspfLsdbOverflow NOTIFICATION-TYPE An ospfLsdbOverflow trap signifies that the number of LSAs in the router's link-state data- base has exceeded ospfExtLsdbLimit. | 1.3.6.1.4.1.1991.0.17 | current |
| snOspfLsdbApproachingOverflow NOTIFICATION-TYPE An ospfLsdbApproachingOverflow trap signifies that the number of LSAs in the router's link- state database has exceeded ninety percent of ospfExtLsdbLimit. | 1.3.6.1.4.1.1991.0.18 | current |
| snTrapL4MaxSessionLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the maximum number of connections reached. | 1.3.6.1.4.1.1991.0.19 | current |
| snTrapL4TcpSynLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the number of TCP SYN limits reached. | 1.3.6.1.4.1.1991.0.20 | current |
| snTrapL4RealServerUp NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server is up. | 1.3.6.1.4.1.1991.0.21 | current |
| snTrapL4RealServerDown NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server is down. | 1.3.6.1.4.1.1991.0.22 | current |
| snTrapL4RealServerPortUp NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server TCP port is up. | 1.3.6.1.4.1.1991.0.23 | current |
| snTrapL4RealServerPortDown NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server TCP port is down. | 1.3.6.1.4.1.1991.0.24 | current |
| snTrapL4RealServerMaxConnectionLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the real server reaches maximum number of connections. | 1.3.6.1.4.1.1991.0.25 | current |
| snTrapL4BecomeStandby NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch changes state from active to standby. | 1.3.6.1.4.1.1991.0.26 | current |
| snTrapL4BecomeActive NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch changes state from standby to active. | 1.3.6.1.4.1.1991.0.27 | current |
| snTrapModuleInserted NOTIFICATION-TYPE The SNMP trap that is generated when a module was inserted to the chassis during system running. | 1.3.6.1.4.1.1991.0.28 | current |
| snTrapModuleRemoved NOTIFICATION-TYPE The SNMP trap that is generated when a module was removed from the chassis during system running. | 1.3.6.1.4.1.1991.0.29 | current |
| snTrapChasPwrSupplyFailed NOTIFICATION-TYPE The SNMP trap that is generated when a power supply operational status changed from normal to failure. | 1.3.6.1.4.1.1991.0.30 | current |
| snTrapChasFanFailed NOTIFICATION-TYPE The SNMP trap that is generated when a fan fails to operate normally. | 1.3.6.1.4.1.1991.0.31 | current |
| snTrapLockedAddressViolation2 NOTIFICATION-TYPE The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port. | 1.3.6.1.4.1.1991.0.32 | current |
| snTrapFsrpIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a FSRP routing device changed state from active to standby or vice-versa. | 1.3.6.1.4.1.1991.0.33 | current |
| snTrapVrrpIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a VRRP routing device switched between states master, backup, intialized or uknown. | 1.3.6.1.4.1.1991.0.34 | current |
| snTrapMgmtModuleRedunStateChange NOTIFICATION-TYPE The SNMP trap that is generated when the management module changes redundancy state. | 1.3.6.1.4.1.1991.0.35 | current |
| snTrapTemperatureWarning NOTIFICATION-TYPE The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold. | 1.3.6.1.4.1.1991.0.36 | current |
| snTrapAccessListDeny NOTIFICATION-TYPE The SNMP trap that is generated when a packet was denied by an access list. | 1.3.6.1.4.1.1991.0.37 | current |
| snTrapMacFilterDeny NOTIFICATION-TYPE The SNMP trap that is generated when a packet was denied by a MAC address filter. | 1.3.6.1.4.1.1991.0.38 | current |
| snTrapL4GslbRemoteUp NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the remote SI is established. | 1.3.6.1.4.1.1991.0.39 | current |
| snTrapL4GslbRemoteDown NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the remote SI is down. | 1.3.6.1.4.1.1991.0.40 | current |
| snTrapL4GslbRemoteControllerUp NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the GSLB SI is established. | 1.3.6.1.4.1.1991.0.41 | current |
| snTrapL4GslbRemoteControllerDown NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the GSLB SI is down. | 1.3.6.1.4.1.1991.0.42 | current |
| snTrapL4GslbHealthCheckIpUp NOTIFICATION-TYPE The SNMP trap that is generated when GSLB health check for an address transitions from down to active state. | 1.3.6.1.4.1.1991.0.43 | current |
| snTrapL4GslbHealthCheckIpDown NOTIFICATION-TYPE The SNMP trap that is generated when GSLB health check for an address transitions from active to down state. | 1.3.6.1.4.1.1991.0.44 | current |
| snTrapL4GslbHealthCheckIpPortUp NOTIFICATION-TYPE The SNMP trap that is generated when a given port for a health check address is up. | 1.3.6.1.4.1.1991.0.45 | current |
| snTrapL4GslbHealthCheckIpPortDown NOTIFICATION-TYPE The SNMP trap that is generated when a given port for a health check address is down. | 1.3.6.1.4.1.1991.0.46 | current |
| snTrapL4FirewallBecomeStandby NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch Firewall changes state from active to standby. | 1.3.6.1.4.1.1991.0.47 | current |
| snTrapL4FirewallBecomeActive NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch Firewall changes state from standby to active. | 1.3.6.1.4.1.1991.0.48 | current |
| snTrapL4FirewallPathUp NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch Firewall path is up. | 1.3.6.1.4.1.1991.0.49 | current |
| snTrapL4FirewallPathDown NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch Firewall path is down. | 1.3.6.1.4.1.1991.0.50 | current |
| snTrapIcmpLocalExceedBurst NOTIFICATION-TYPE The SNMP trap that is generated when incoming ICMP exceeds burst-MAX. | 1.3.6.1.4.1.1991.0.51 | current |
| snTrapIcmpTransitExceedBurst NOTIFICATION-TYPE The SNMP trap that is generated when transit ICMP exceeds burst-MAX. | 1.3.6.1.4.1.1991.0.52 | current |
| snTrapTcpLocalExceedBurst NOTIFICATION-TYPE The SNMP trap that is generated when incoming TCP SYN exceeds burst-MAX. | 1.3.6.1.4.1.1991.0.53 | current |
| snTrapTcpTransitExceedBurst NOTIFICATION-TYPE The SNMP trap that is generated when transit TCP exceeds burst-MAX. | 1.3.6.1.4.1.1991.0.54 | current |
| snTrapL4ContentVerification NOTIFICATION-TYPE The SNMP trap that is generated when the HTTP match-list pattern is found. | 1.3.6.1.4.1.1991.0.55 | current |
| snTrapDuplicateIp NOTIFICATION-TYPE Duplicate IP address detected. | 1.3.6.1.4.1.1991.0.56 | current |
| snTrapMplsProblem NOTIFICATION-TYPE NOT IMPLEMENTED: MPLS Problem Detected. | 1.3.6.1.4.1.1991.0.57 | obsolete |
| snTrapMplsException NOTIFICATION-TYPE NOT IMPLEMENTED: MPLS Exception Detected. | 1.3.6.1.4.1.1991.0.58 | obsolete |
| snTrapMplsAudit NOTIFICATION-TYPE NOT IMPLEMENTED: MPLS Audit Trap. | 1.3.6.1.4.1.1991.0.59 | obsolete |
| snTrapMplsDeveloper NOTIFICATION-TYPE NOT IMPLEMENTED: MPLS Developer Trap. | 1.3.6.1.4.1.1991.0.60 | obsolete |
| snTrapNoBmFreeQueue NOTIFICATION-TYPE The SNMP trap that is generated when no free queue is available in buffer manager. | 1.3.6.1.4.1.1991.0.61 | current |
| snTrapSmcDmaDrop NOTIFICATION-TYPE The SNMP trap that is generated when SMC DMA packet is dropped. | 1.3.6.1.4.1.1991.0.62 | current |
| snTrapSmcBpDrop NOTIFICATION-TYPE The SNMP trap that is generated when SMC BackPlane packet is dropped. | 1.3.6.1.4.1.1991.0.63 | current |
| snTrapBmWriteSeqDrop NOTIFICATION-TYPE The SNMP trap that is generated when BM write sequence packet is dropped. | 1.3.6.1.4.1.1991.0.64 | current |
| snTrapBgpPeerUp NOTIFICATION-TYPE The SNMP trap that is generated when the bgp peer is up. | 1.3.6.1.4.1.1991.0.65 | current |
| snTrapBgpPeerDown NOTIFICATION-TYPE The SNMP trap that is generated when the bgp peer is down. | 1.3.6.1.4.1.1991.0.66 | current |
| snTrapL4RealServerResponseTimeLowerLimit NOTIFICATION-TYPE The SNMP trap that is generated when the real server average response time exceeds lower threshold. | 1.3.6.1.4.1.1991.0.67 | current |
| snTrapL4RealServerResponseTimeUpperLimit NOTIFICATION-TYPE The SNMP trap that is generated when the real server average response time exceeds upper threshold. | 1.3.6.1.4.1.1991.0.68 | current |
| snTrapL4TcpAttackRateExceedMax NOTIFICATION-TYPE The SNMP trap that is generated when the TCP attack rate exceeds configured maximum. | 1.3.6.1.4.1.1991.0.69 | current |
| snTrapL4TcpAttackRateExceedThreshold NOTIFICATION-TYPE The SNMP trap that is generated when the TCP attack rate exceeds 80% of configured maximum. | 1.3.6.1.4.1.1991.0.70 | current |
| snTrapL4ConnectionRateExceedMax NOTIFICATION-TYPE The SNMP trap that is generated when the L4 connection rate exceeds configured maximum. | 1.3.6.1.4.1.1991.0.71 | current |
| snTrapL4ConnectionRateExceedThreshold NOTIFICATION-TYPE The SNMP trap that is generated when the L4 connection rate exceeds 80% of configured maximum | 1.3.6.1.4.1.1991.0.72 | current |
| snTrapRunningConfigChanged NOTIFICATION-TYPE The SNMP trap that is generated when the running configuration was changed. | 1.3.6.1.4.1.1991.0.73 | current |
| snTrapStartupConfigChanged NOTIFICATION-TYPE The SNMP trap that is generated when the startup configuration was changed. | 1.3.6.1.4.1.1991.0.74 | current |
| snTrapUserLogin NOTIFICATION-TYPE The SNMP trap that is generated when user login. | 1.3.6.1.4.1.1991.0.75 | current |
| snTrapUserLogout NOTIFICATION-TYPE The SNMP trap that is generated when user logout. | 1.3.6.1.4.1.1991.0.76 | current |
| snTrapPortSecurityViolation NOTIFICATION-TYPE The SNMP trap that is generated when insecure MAC addresses are received from a port with MAC security feature enabled. | 1.3.6.1.4.1.1991.0.77 | current |
| snTrapPortSecurityShutdown NOTIFICATION-TYPE The SNMP trap that is generated when insecure MAC addresses are received from a port caused the port to shutdown. | 1.3.6.1.4.1.1991.0.78 | current |
| snTrapMrpStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a MRP switching and routing device changed state to disabled, blocking, preforwarding, forwarding, uknown. | 1.3.6.1.4.1.1991.0.79 | current |
| snTrapMrpCamError NOTIFICATION-TYPE The SNMP trap that is generated when a MRP Cam Error occurs. | 1.3.6.1.4.1.1991.0.80 | current |
| snTrapChasPwrSupplyOK NOTIFICATION-TYPE The SNMP trap that is generated when a power supply operational status changed from failure to normal. | 1.3.6.1.4.1.1991.0.81 | current |
| snTrapVrrpeIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a VRRPE routing device switched between states master, backup, intialized or uknown. | 1.3.6.1.4.1.1991.0.82 | current |
| snTrapVsrpIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a VSRP switching and routing device switched between states master, backup, intialized or uknown. | 1.3.6.1.4.1.1991.0.83 | current |
| snTrapSrcIpAddressViolation NOTIFICATION-TYPE The SNMP trap that is generated when a rogue device spoofs source IP address for denial of service attack. | 1.3.6.1.4.1.1991.0.84 | current |
| snTrapMacAuthEnable NOTIFICATION-TYPE The SNMP trap that is generated when MAC-Authentication is enabled on an interface. | 1.3.6.1.4.1.1991.0.85 | current |
| snTrapMacAuthDisable NOTIFICATION-TYPE The SNMP trap that is generated when MAC-Authentication is disabled on an interface. | 1.3.6.1.4.1.1991.0.86 | current |
| snTrapMacAuthMACAccepted NOTIFICATION-TYPE The SNMP trap that is generated when MAC-Authentication is successful on an interface. | 1.3.6.1.4.1.1991.0.87 | current |
| snTrapMacAuthMACRejected NOTIFICATION-TYPE The SNMP trap that is generated when MAC-Authentication is failed on an interface. | 1.3.6.1.4.1.1991.0.88 | current |
| snTrapMacAuthPortDisabled NOTIFICATION-TYPE The SNMP trap that is generated when an interface is disabled due to MAC-Authentication detecting a DOS attack on that interface. | 1.3.6.1.4.1.1991.0.89 | current |
| snTrapClientLoginReject NOTIFICATION-TYPE The SNMP trap that is generated when a login attempt by a telnet or SSH client fails. | 1.3.6.1.4.1.1991.0.110 | current |
| snTrapLocalUserConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a local user configuration is changed. | 1.3.6.1.4.1.1991.0.111 | current |
| snTrapVlanConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a vlan configuration is changed. | 1.3.6.1.4.1.1991.0.112 | current |
| snTrapAclConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a ACL configuration is changed. | 1.3.6.1.4.1.1991.0.113 | current |
| snTrapMacFilterConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a MAC Filter configuration is changed. | 1.3.6.1.4.1.1991.0.114 | current |
| snTrapSNMPConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a SNMP configuration is changed. | 1.3.6.1.4.1.1991.0.115 | current |
| snTrapSyslogConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a Syslog configuration is changed. | 1.3.6.1.4.1.1991.0.116 | current |
| snTrapPasswordConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when enable or line password is changed. | 1.3.6.1.4.1.1991.0.117 | current |
| snTrapServerStatusChange NOTIFICATION-TYPE The SNMP trap that is generated when a server is disabled or enabled. | 1.3.6.1.4.1.1991.0.118 | current |
| snTrapL4RealServerPortMaxConnectionLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the real server's port reaches maximum number of connections. | 1.3.6.1.4.1.1991.0.119 | current |
| snTrapL4LinkDown NOTIFICATION-TYPE The SNMP trap that is generated when the ISP link goes down. | 1.3.6.1.4.1.1991.0.120 | current |
| snTrapL4LinkUp NOTIFICATION-TYPE The SNMP trap that is generated when the ISP link goes up. | 1.3.6.1.4.1.1991.0.121 | current |
| snTrapPortPriorityChange NOTIFICATION-TYPE The SNMP trap that is generated when the priority of a port is changed. | 1.3.6.1.4.1.1991.0.122 | current |
| snTrapAutoPortDisableTrigger NOTIFICATION-TYPE The SNMP trap that is generated when automatic port disable was triggered. | 1.3.6.1.4.1.1991.0.123 | current |
| snTrapAutoPortDisableRelease NOTIFICATION-TYPE The SNMP trap that is generated when automatic port disable was released. | 1.3.6.1.4.1.1991.0.124 | current |
| snTrapPnPStatusChange NOTIFICATION-TYPE The SNMP trap that is generated when plug-and-play status change. | 1.3.6.1.4.1.1991.0.125 | current |
| snTrapWirelessIsrpPeerStateChange NOTIFICATION-TYPE The SNMP trap that is generated when ISRP Peer changes state. | 1.3.6.1.4.1.1991.0.126 | current |
| snTrapWirelessStationStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a wireless station's state changes. | 1.3.6.1.4.1.1991.0.127 | current |
| snTrapWirelessStationRoamingEventTriggered NOTIFICATION-TYPE The SNMP trap that is generated when we received a MOVE request from the AP | 1.3.6.1.4.1.1991.0.128 | current |
| snTrapWirelessSappStateChange NOTIFICATION-TYPE The SNMP trap that is generated when SAPP between an AP and a FIPS changes state. | 1.3.6.1.4.1.1991.0.129 | current |
| snTrapExternalPowerConnectionStatus NOTIFICATION-TYPE The SNMP trap that is generated when the external power supply connecting or disconnecting to a power over ethernet module. | 1.3.6.1.4.1.1991.0.130 | current |
| snTrapDot1xSecurityViolation NOTIFICATION-TYPE The SNMP trap that is generated when a malicious mac address was detected. | 1.3.6.1.4.1.1991.0.131 | current |
| snTrapDot1xPortLinkChange NOTIFICATION-TYPE The SNMP trap that is generated when software port link status has changed to up or down. | 1.3.6.1.4.1.1991.0.132 | current |
| snTrapDot1xPortControlChange NOTIFICATION-TYPE The SNMP trap that is generated when software port control status has changed to authorize or unauthorize. | 1.3.6.1.4.1.1991.0.133 | current |
| snTrapDot1xVlanIdChange NOTIFICATION-TYPE The SNMP trap that is generated when VLAN ID of a port has changed. | 1.3.6.1.4.1.1991.0.134 | current |
| snTrapDot1xFilterSetupFailure NOTIFICATION-TYPE The SNMP trap that is generated when software failed to setup a filter to a mac address of a port. | 1.3.6.1.4.1.1991.0.135 | current |
| snTrapDot1xError NOTIFICATION-TYPE The SNMP trap that is generated when software detected system error. | 1.3.6.1.4.1.1991.0.136 | current |
| snTrapPortConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when a port configuration is changed. | 1.3.6.1.4.1.1991.0.137 | current |
| snTrapMacAuthVlanIdChange NOTIFICATION-TYPE The SNMP trap that is generated when VLAN ID of a port has changed. | 1.3.6.1.4.1.1991.0.138 | current |
| snTrapWebAuthEnabled NOTIFICATION-TYPE The SNMP trap that is generated when web authentication is enabled. | 1.3.6.1.4.1.1991.0.139 | current |
| snTrapWebAuthDisabled NOTIFICATION-TYPE The SNMP trap that is generated when web authentication is disabled. | 1.3.6.1.4.1.1991.0.140 | current |
| snTrapIpConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when IP system address changes. | 1.3.6.1.4.1.1991.0.141 | current |
| snTrapIpv6ConfigChange NOTIFICATION-TYPE The SNMP trap that is generated when IPv6 system address changes. | 1.3.6.1.4.1.1991.0.142 | current |
| snTrapMacAuthRadiusTimeout NOTIFICATION-TYPE The SNMP trap that is generated when a request from Mac-Auth to RADIUS has not been answered within the retry and time limit. | 1.3.6.1.4.1.1991.0.143 | current |
| snTrapDot1xRadiusTimeout NOTIFICATION-TYPE The SNMP trap that is generated when a request from 802.1x to RADIUS has not been answered within the retry and time limit. | 1.3.6.1.4.1.1991.0.144 | current |
| snTrapUDLDLinkDown NOTIFICATION-TYPE The SNMP trap that is generated when UDLD port link status has changed to down. | 1.3.6.1.4.1.1991.0.145 | current |
| snTrapUDLDLinkUp NOTIFICATION-TYPE The SNMP trap that is generated when UDLD port link status has changed to up. | 1.3.6.1.4.1.1991.0.146 | current |
| snTrapMacBasedVlanEnabled NOTIFICATION-TYPE The SNMP trap that is generated when MAC based VLAN is enabled. | 1.3.6.1.4.1.1991.0.147 | current |
| snTrapMacBasedVlanDisabled NOTIFICATION-TYPE The SNMP trap that is generated when MAC based VLAN is disabled. | 1.3.6.1.4.1.1991.0.148 | current |
| snTrapChasFanNormal NOTIFICATION-TYPE The SNMP trap that is generated when a fan operational status changed from failure to normal. | 1.3.6.1.4.1.1991.0.149 | current |
| snTrapStpRootGuardDetect NOTIFICATION-TYPE The SNMP trap that is generated when VLAN's Root-Guarded port received superior BPDU. | 1.3.6.1.4.1.1991.0.150 | current |
| snTrapStpRootGuardExpire NOTIFICATION-TYPE The SNMP trap that is generated when VLAN's ports's Root-Guard expire. | 1.3.6.1.4.1.1991.0.151 | current |
| snTrapStpBPDUGuardDetect NOTIFICATION-TYPE The SNMP trap that is generated when VLAN's BPDU-guarded port received BPDU . | 1.3.6.1.4.1.1991.0.152 | current |
| snTrapMstpBPDUGuardDetect NOTIFICATION-TYPE The SNMP trap that is generated when BPDU-guarded port received BPDU . | 1.3.6.1.4.1.1991.0.153 | current |
| snTrapErrorDisableAction NOTIFICATION-TYPE The SNMP trap that is generated when Interface error-disable is hit or recovery times out . | 1.3.6.1.4.1.1991.0.154 | current |
| snTrapLACPLinkStateChange NOTIFICATION-TYPE The SNMP trap that is generated when LACP port changes its state. | 1.3.6.1.4.1.1991.0.155 | current |
| snTrapOpticalMonitoringNotFoundryOptics NOTIFICATION-TYPE The SNMP trap that is generated if optical monitoring is enabled but optics vendor is not Foundry Networks. | 1.3.6.1.4.1.1991.0.156 | current |
| snTrapOpticalMonitoringFoundryOpticsNotCapable NOTIFICATION-TYPE The SNMP trap that is generated if optical monitoring is enabled but the Foundry optic is not capable. | 1.3.6.1.4.1.1991.0.157 | current |
| snTrapStaticMulticastMacConfigAdd NOTIFICATION-TYPE The SNMP trap that is generated if a new entry is added to static multicast mac configuration table. Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id> | 1.3.6.1.4.1.1991.0.158 | current |
| snTrapStaticMulticastMacConfigRemove NOTIFICATION-TYPE The SNMP trap that is generated if an entry is removed from static multicast mac configuration table . Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id> | 1.3.6.1.4.1.1991.0.159 | current |
| snTrapSTPBPDUGuardExpire NOTIFICATION-TYPE The SNMP notification that is generated when a port is re-enabled after being disabled due to BPDU Guard Violation. Format: STP: BPDU Guard re-enabled on VLAN <id> port <slot>/<port> | 1.3.6.1.4.1.1991.0.160 | current |
| snTrapPortLoopDetection NOTIFICATION-TYPE The SNMP notification is generated when a port loop is detected. Format: LOOP DETECTION: VLAN <id>, port <slot>/<port> detect, putting into err-disable state | 1.3.6.1.4.1.1991.0.161 | current |
| snTrapNoFreeTcamEntry NOTIFICATION-TYPE The SNMP trap that is generated when system is running out of TCAM spaces allocated for routing entries. | 1.3.6.1.4.1.1991.0.162 | current |
| snTrapStackingMasterElected NOTIFICATION-TYPE The SNMP trap that is generated when a unit is elected as Master unit for the stacking system. | 1.3.6.1.4.1.1991.0.163 | current |
| snTrapStackingUnitAdded NOTIFICATION-TYPE The SNMP trap that is generated when a unit has been added to the stacking system. | 1.3.6.1.4.1.1991.0.164 | current |
| snTrapStackingUnitDeleted NOTIFICATION-TYPE The SNMP trap that is generated when a unit has been deleted from the stacking system. | 1.3.6.1.4.1.1991.0.165 | current |
| snTrapStackingChasPwrSupplyOK NOTIFICATION-TYPE The SNMP trap that is generated when a power supply operational status changed from failure to normal for a stacking system. | 1.3.6.1.4.1.1991.0.166 | current |
| snTrapStackingChasPwrSupplyFailed NOTIFICATION-TYPE The SNMP trap that is generated when a power supply operational status changed from normal to failure for a stacking system. | 1.3.6.1.4.1.1991.0.167 | current |
| snTrapStackingChasFanNormal NOTIFICATION-TYPE The SNMP trap that is generated when a fan operational status changed from failure to normal for a stacking system | 1.3.6.1.4.1.1991.0.168 | current |
| snTrapStackingChasFanFailed NOTIFICATION-TYPE The SNMP trap that is generated when a fan fails to operate normally for a stacking system. | 1.3.6.1.4.1.1991.0.169 | current |
| snTrapStackingManagementMACChanged NOTIFICATION-TYPE The SNMP trap that is generated when the managemnet MAC address of a stacking system has been changed. | 1.3.6.1.4.1.1991.0.170 | current |
| snTrapStackingTemperatureWarning NOTIFICATION-TYPE The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold for a stack sytem. | 1.3.6.1.4.1.1991.0.171 | current |
| snTrapIfIndexAssignmentChanged NOTIFICATION-TYPE The SNMP trap that is generated when the Interface Index (IfIndex) assignment for the physical interfaces was changed. | 1.3.6.1.4.1.1991.0.172 | current |
| snTrapPBRConfigChanged NOTIFICATION-TYPE The SNMP trap that is generated when a Policy Based Routing (PBR) routemap is bound or unbound either globally or to an interface. | 1.3.6.1.4.1.1991.0.173 | current |
| snTrapChasPwrSupplyRPSAdd NOTIFICATION-TYPE The SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is added to the system. | 1.3.6.1.4.1.1991.0.174 | current |
| snTrapChasPwrSupplyRPSRemove NOTIFICATION-TYPE The SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is removed from the system. | 1.3.6.1.4.1.1991.0.175 | current |
| snTrapModuleStatusChange NOTIFICATION-TYPE The SNMP notification that is generated when a module's operational state changes. The management entity receiving the notification can identify the module and the event by referencing snChasUnitIndex, snAgentBrdIndex, snAgentBrdModuleStatus. In case of a module-down event, the varbind snAgGblTrapMessage is a text string that describes the cause. In case of module-up event, snAgGblTrapMessage is a null string. | 1.3.6.1.4.1.1991.0.176 | current |
| snTrapChasHighSpeedFansNeeded NOTIFICATION-TYPE The SNMP trap that is generated when chassis doesn't have high speed fans for specific modules | 1.3.6.1.4.1.1991.0.177 | current |
| snTrapSysmaxReverted NOTIFICATION-TYPE The SNMP trap that is generated when the revertible sysmax elements are reverted during the card bringup if they can not be accomodated in the available memory. | 1.3.6.1.4.1.1991.0.178 | current |
| snTrapSysmaxLeftLowMem NOTIFICATION-TYPE The SNMP trap that is generated when its found during bootup that the configured sysmax set shall leave less than 10% available memory free. | 1.3.6.1.4.1.1991.0.179 | current |
| snTrapSysMemoryLowThreshold NOTIFICATION-TYPE The SNMP trap that is generated when the available dynamic memory in a card is below 5% of the installed physical memory. | 1.3.6.1.4.1.1991.0.180 | current |
| snTrapSysMemoryOutThreshold NOTIFICATION-TYPE The SNMP trap that is generated when the dynamic memory fails to be allocated in a system. | 1.3.6.1.4.1.1991.0.181 | current |
| snTrapLinkOAMLinkDown NOTIFICATION-TYPE The SNMP trap that is generated when Link-OAM port link status has changed to down. | 1.3.6.1.4.1.1991.0.182 | current |
| snTrapLinkOAMLinkUp NOTIFICATION-TYPE The SNMP trap that is generated when Link-OAM port link status has changed to up. | 1.3.6.1.4.1.1991.0.183 | current |
| snTrapI2CAccessLog NOTIFICATION-TYPE The SNMP trap that is generated to provide information about state of the management module's I2C accesses. | 1.3.6.1.4.1.1991.0.184 | current |
| snTrapLinkOAMLoopbackEntered NOTIFICATION-TYPE The SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more. | 1.3.6.1.4.1.1991.0.185 | current |
| snTrapLinkOAMLoopbackCleared NOTIFICATION-TYPE The SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more. | 1.3.6.1.4.1.1991.0.186 | current |
| snTrapLicenseAdded NOTIFICATION-TYPE The SNMP trap that is generated when a new license is added to the system. | 1.3.6.1.4.1.1991.0.187 | current |
| snTrapLicenseRemoved NOTIFICATION-TYPE The SNMP trap that is generated when an existing license is removed from the system. | 1.3.6.1.4.1.1991.0.188 | current |
| snTrapLicenseExpires NOTIFICATION-TYPE The SNMP trap that is generated when a trial license is about to expire. This trap is generated daily for last 3 days and every 2 hours on the last day of expire. | 1.3.6.1.4.1.1991.0.189 | current |
| snTrapLicenseExpired NOTIFICATION-TYPE The SNMP trap that is generated when a trial license has expired. | 1.3.6.1.4.1.1991.0.190 | current |
| snTrapUDLDCrcFailureDetected NOTIFICATION-TYPE The SNMP trap that is generated when UDLD detects CRC failures on PDUs received on a port | 1.3.6.1.4.1.1991.0.191 | current |
| snTrapDot1agCfmRemoteMEPAgeOut NOTIFICATION-TYPE The SNMP trap that is generated when 802.1ag Remote MEP ages out. | 1.3.6.1.4.1.1991.0.192 | current |
| snTrapDot1agCfmRemoteMEPUp NOTIFICATION-TYPE The SNMP trap that is generated when 802.1ag Remote MEP is up. | 1.3.6.1.4.1.1991.0.193 | current |
| snTrapDot1agCfmDomainCrossConnection NOTIFICATION-TYPE The SNMP trap that is generated when 802.1ag domain gets cross-connected. | 1.3.6.1.4.1.1991.0.194 | current |
| snTrapDot1agCfmDuplicateMEPId NOTIFICATION-TYPE The SNMP trap that is generated when 802.1ag Remote MEP reports a duplicate MEP Id that conflicts with local MEP Id. | 1.3.6.1.4.1.1991.0.195 | current |
| snTrapStackingStandbyElected NOTIFICATION-TYPE The SNMP trap that is generated when a unit is elected as Standby unit for the stacking system. | 1.3.6.1.4.1.1991.0.196 | current |
| snTrapMacMoveThresholdRate NOTIFICATION-TYPE The SNMP notification is generated when MAC movement exceeding the certain threshold for a sampling interval is detected. Format: Mac-Move threshold-rate: MAC address <mac> moved from interface <port-id> to interface <port-id> for vlan <vlan-id>, <move-count> times exceeding the threshold rate <threshold-rate> for a sampling interval <interval> seconds | 1.3.6.1.4.1.1991.0.197 | current |
| snTrapMacMoveIntervalHistory NOTIFICATION-TYPE The SNMP notification is generated every user configured interval, summarizing the moves in the interval . Format: Mac-Move Interval-History: <#macs> macs moved in last <interval> seconds. Total number of mac moves in the interval is <#moves> | 1.3.6.1.4.1.1991.0.198 | current |
| snTrapChasFanOK NOTIFICATION-TYPE The SNMP trap that is generated when a fan operational status changed from failure to normal or change in the fan speed due to temperature variations downwards. | 1.3.6.1.4.1.1991.0.1000 | current |
| snTrapTemperatureOK NOTIFICATION-TYPE The SNMP trap that is generated when the actual temperature reading is below the warning temperature threshold. | 1.3.6.1.4.1.1991.0.1001 | current |
| snTrapCAMOverflow NOTIFICATION-TYPE The SNMP trap that is generated when any CAM partition becomes full. | 1.3.6.1.4.1.1991.0.1002 | current |
| snTrapOpticalMonitoringWarning NOTIFICATION-TYPE The SNMP trap that is generated if there is a warning during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1003 | current |
| snTrapOpticalMonitoringAlarm NOTIFICATION-TYPE The SNMP trap that is generated if there is an alarm during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1004 | current |
| snTrapOpticalMonitoringError NOTIFICATION-TYPE The SNMP trap that is generated if there is an error during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1005 | current |
| snTrapPosMonitoringWarning NOTIFICATION-TYPE The SNMP trap that is generated if there is a warning during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1006 | current |
| snTrapPosMonitoringAlarm NOTIFICATION-TYPE The SNMP trap that is generated if there is an alarm up/down during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1007 | current |
| snTrapPosMonitoringError NOTIFICATION-TYPE The SNMP trap that is generated if there is an error during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1008 | current |
| snTrapXfpSfpIncompatibleOptics NOTIFICATION-TYPE The SNMP trap that is generated if optics is incompatible with port configuration. | 1.3.6.1.4.1.1991.0.1009 | current |
| snTrapTMLoggingStart NOTIFICATION-TYPE The SNMP trap that is generated if TM logging is started by an event trigger. | 1.3.6.1.4.1.1991.0.1015 | current |
| snTrapTMLoggingStop NOTIFICATION-TYPE The SNMP trap that is generated if TM logging stopped due to storage full. | 1.3.6.1.4.1.1991.0.1016 | current |
| snTrapTMLoggingRestart NOTIFICATION-TYPE The SNMP trap that is generated if TM logging restarted after user clearing the log. | 1.3.6.1.4.1.1991.0.1017 | current |
| snTrapXfpSfpNotFoundryOptics NOTIFICATION-TYPE The SNMP trap that is generated if optics vendor is not Foundry Networks. | 1.3.6.1.4.1.1991.0.1018 | current |
| snTrapTMRecoverySlotReset NOTIFICATION-TYPE The SNMP trap that is generated when TM recovery slot reset is triggered. | 1.3.6.1.4.1.1991.0.1019 | current |
| snTrapTMEgressDataError NOTIFICATION-TYPE The SNMP trap that is generated when system detects egress data errors on Traffic Manager. For e.g. Fabric Monitoring : TM Egress data errors detected on LP <num>/TM <num> | 1.3.6.1.4.1.1991.0.1020 | current |
| snTrapSFMLinkDown NOTIFICATION-TYPE The SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is down. For eg. Fabric Monitoring Link Down : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num> | 1.3.6.1.4.1.1991.0.1100 | current |
| snTrapSFMLinkUp NOTIFICATION-TYPE The SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is up. For eg. Fabric Monitoring Link Up : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num> | 1.3.6.1.4.1.1991.0.1101 | current |
| snTrapSFMAccessError NOTIFICATION-TYPE The SNMP trap that is generated when system fails to access a SFM Fabric Element. For e.g. Fabric Monitoring : Device access failure in SFM <num>/FE <num> | 1.3.6.1.4.1.1991.0.1102 | current |
| snTrapSFMStatusChange NOTIFICATION-TYPE The SNMP notification that is generated when there is a change in the operational state of the Switch Fabric Module (SFM). For example, System: Health Monitoring: SFM <num> powered off due to failure detection | 1.3.6.1.4.1.1991.0.1103 | current |
| snTrapLPFabricStatusChange NOTIFICATION-TYPE Health Monitoring: LP Fabric status change. | 1.3.6.1.4.1.1991.0.1104 | current |
| snTrapChassisFanSpeedLow NOTIFICATION-TYPE The SNMP trap that is generated when all chassis fans change to low speed. | 1.3.6.1.4.1.1991.0.1200 | current |
| snTrapChassisFanSpeedMedium NOTIFICATION-TYPE The SNMP trap that is generated when all chassis fans change to medium speed. | 1.3.6.1.4.1.1991.0.1201 | current |
| snTrapChassisFanSpeedMedHigh NOTIFICATION-TYPE The SNMP trap that is generated when all chassis fans change to medium high speed. | 1.3.6.1.4.1.1991.0.1202 | current |
| snTrapChassisFanSpeedHigh NOTIFICATION-TYPE The SNMP trap that is generated when all chassis fans change to high speed. | 1.3.6.1.4.1.1991.0.1203 | current |
| snTrapFIPSModeEnable NOTIFICATION-TYPE The SNMP trap that is generated when FIPS mode is enabled. | 1.3.6.1.4.1.1991.0.1207 | current |
| snTrapFIPSModeDisable NOTIFICATION-TYPE The SNMP trap that is generated when FIPS mode is disabled. | 1.3.6.1.4.1.1991.0.1208 | current |
| snTrapFIPSHostZeroized NOTIFICATION-TYPE The SNMP trap that is generated when host keys are zeroized in FIPS mode | 1.3.6.1.4.1.1991.0.1209 | current |
| snTrapFIPSSharedSecretZeroized NOTIFICATION-TYPE The SNMP trap that is generated when shared secret are zeroized in FIPS mode | 1.3.6.1.4.1.1991.0.1210 | current |
| snTrapFIPSPOSTStatus NOTIFICATION-TYPE The SNMP trap that is generated after POST. | 1.3.6.1.4.1.1991.0.1211 | current |
| snTrapFIPSCryptoModuleFailure NOTIFICATION-TYPE The SNMP trap that is generated on cryptographic module failure. | 1.3.6.1.4.1.1991.0.1212 | current |
| snTrapLicense2PortNotSupported NOTIFICATION-TYPE The SNMP trap that is generated when a 2 port license cannot be applied due to hardware limitation. | 1.3.6.1.4.1.1991.0.1213 | current |
| snTrapOpticalMonitoringOK NOTIFICATION-TYPE The SNMP trap that is generated when an interface transitions from an error to normal state because the alarms/warnings are below the threshold. snTrapOpticalMonitoringError would have been earlier generated when the interface transitioned to the error state. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff. | 1.3.6.1.4.1.1991.0.1214 | current |
| snTrapSFMAccessOK NOTIFICATION-TYPE The SNMP trap that is generated when system can successfully access an SFM Fabric Element. snTrapSFMAccessError would have been generated when the system failed to access the FE. For e.g. Fabric Monitoring : Device SFM <num>/FE <num> is OK to access. | 1.3.6.1.4.1.1991.0.1215 | current |
| snTrapUpgradeSingleCmdStart NOTIFICATION-TYPE The SNMP trap that is generated when the single-command package upgrade has started. This happens after a successful download and validation of manifest file and before the first image download takes place. | 1.3.6.1.4.1.1991.0.1216 | current |
| snTrapUpgradeSingleCmdDone NOTIFICATION-TYPE The SNMP trap that is generated when the single-command package upgrade completed, or partially completed. The table brcdSwPackageLoadResultTable lists the result of the upgrade. | 1.3.6.1.4.1.1991.0.1217 | current |
| snTrapAutoUpgradeStart NOTIFICATION-TYPE The SNMP trap that is generated when an auto-upgrade on a line card has started. | 1.3.6.1.4.1.1991.0.1218 | current |
| snTrapAutoUpgradeDone NOTIFICATION-TYPE The SNMP trap that is generated when the auto-upgrade of interface module completed. | 1.3.6.1.4.1.1991.0.1219 | current |