Description

The MIB module for representing multiple logical entities supported by a single SNMP agent. Copyright (c) 2013 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info).

Contact

WG Email: eman@ietf.org Mailing list subscription info: http://www.ietf.org/mailman/listinfo/eman Andy Bierman YumaWorks, Inc. 274 Redwood Shores Parkway, #133 Redwood City, CA 94065 USA Phone: +1 408-716-0466 Email: andy@yumaworks.com Dan Romascanu Avaya Park Atidim, Bldg. #3 Tel Aviv, 61581 Israel Phone: +972-3-6458414 Email: dromasca@avaya.com Juergen Quittek NEC Europe Ltd. Network Research Division Kurfuersten-Anlage 36 Heidelberg 69115 Germany Phone: +49 6221 4342-115 Email: quittek@neclab.eu Mouli Chandramouli Cisco Systems, Inc. Sarjapur Outer Ring Road Bangalore 560103 India Phone: +91 80 4429 2409 Email: moulchan@cisco.com

Imports

FromSymbols
IANA-ENTITY-MIBIANAPhysicalClass
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, mib-2
SNMPv2-TCAutonomousType, DateAndTime, DisplayString, RowPointer, TAddress, TDomain, TEXTUAL-CONVENTION, TimeStamp, TruthValue
UUID-TC-MIBUUIDorZero

Imported by

185 module(s) in this corpus import this one; the first 50 are listed.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
IANA-ENTITY-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
PhysicalClass
TEXTUAL-CONVENTION
Starting with version 4 of the ENTITY-MIB, this TC is deprecated, and the usage of the IANAPhysicalClass TC from the IANA-ENTITY-MIB is recommended instead. An enumerated value that provides an indication of the general hardware type of a particular physical entity. There are no restrictions as to the number of entPhysicalEntries of each entPhysicalClass, which must be instantiated by an agent. The enumeration 'other' is applicable if the physical entity class is known but does not match any of the supported values. The enumeration 'unknown' is applicable if the physical entity class is unknown to the agent. The enumeration 'chassis' is applicable if the physical entity class is an overall container for networking equipment. Any class of physical entity, except a stack, may be contained within a chassis; a chassis may only be contained within a stack. The enumeration 'backplane' is applicable if the physical entity class is some sort of device for aggregating and forwarding networking traffic, such as a shared backplane in a modular ethernet switch. Note that an agent may model a backplane as a single physical entity, which is actually implemented as multiple discrete physical components (within a chassis or stack). The enumeration 'container' is applicable if the physical entity class is capable of containing one or more removable physical entities, possibly of different types. For example, each (empty or full) slot in a chassis will be modeled as a container. Note that all removable physical entities should be modeled within a container entity, such as field-replaceable modules, fans, or power supplies. Note that all known containers should be modeled by the agent, including empty containers. The enumeration 'powerSupply' is applicable if the physical entity class is a power-supplying component. The enumeration 'fan' is applicable if the physical entity class is a fan or other heat-reduction component. The enumeration 'sensor' is applicable if the physical entity class is some sort of sensor, such as a temperature sensor within a router chassis. The enumeration 'module' is applicable if the physical entity class is some sort of self-contained sub-system. If the enumeration 'module' is removable, then it should be modeled within a container entity; otherwise, it should be modeled directly within another physical entity (e.g., a chassis or another module). The enumeration 'port' is applicable if the physical entity class is some sort of networking port capable of receiving and/or transmitting networking traffic. The enumeration 'stack' is applicable if the physical entity class is some sort of super-container (possibly virtual) intended to group together multiple chassis entities. A stack may be realized by a 'virtual' cable, a real interconnect cable, attached to multiple chassis, or may in fact be comprised of multiple interconnect cables. A stack should not be modeled within any other physical entities, but a stack may be contained within another stack. Only chassis entities should be contained within a stack. The enumeration 'cpu' is applicable if the physical entity class is some sort of central processing unit.
deprecated
PhysicalIndex
TEXTUAL-CONVENTION
An arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous.
current
PhysicalIndexOrZero
TEXTUAL-CONVENTION
This TEXTUAL-CONVENTION is an extension of the PhysicalIndex convention, which defines a greater than zero value used to identify a physical entity. This extension permits the additional value of zero. The semantics of the value zero are object-specific and must, therefore, be defined as part of the description of any object that uses this syntax. Examples of the usage of this extension are situations where none or all physical entities need to be referenced.
current
SnmpEngineIdOrNone
TEXTUAL-CONVENTION
A specially formatted SnmpEngineID string for use with the Entity MIB. If an instance of an object of SYNTAX SnmpEngineIdOrNone has a non-zero length, then the object encoding and semantics are defined by the SnmpEngineID TEXTUAL-CONVENTION (see STD 62, RFC 3411). If an instance of an object of SYNTAX SnmpEngineIdOrNone contains a zero-length string, then no appropriate SnmpEngineID is associated with the logical entity (i.e., SNMPv3 is not supported).
current

Objects

NameOIDSyntaxAccessStatus
entityMIBObjects
OBJECT-IDENTITY
1.3.6.1.2.1.47.1
entityPhysical
OBJECT-IDENTITY
1.3.6.1.2.1.47.1.1
entPhysicalTable
OBJECT-TYPE
This table contains one row per physical entity. There is always at least one row for an 'overall' physical entity.
1.3.6.1.2.1.47.1.1.1not-accessiblecurrent
entPhysicalEntry
OBJECT-TYPE
Information about a particular physical entity. Each entry provides objects (entPhysicalDescr, entPhysicalVendorType, and entPhysicalClass) to help an NMS identify and characterize the entry and objects (entPhysicalContainedIn and entPhysicalParentRelPos) to help an NMS relate the particular entry to other entries in this table.
1.3.6.1.2.1.47.1.1.1.1not-accessiblecurrent
entPhysicalIndex
OBJECT-TYPE
The index for this entry.
1.3.6.1.2.1.47.1.1.1.1.1PhysicalIndexnot-accessiblecurrent
entPhysicalDescr
OBJECT-TYPE
A textual description of physical entity. This object should contain a string that identifies the manufacturer's name for the physical entity and should be set to a distinct value for each version or model of the physical entity.
1.3.6.1.2.1.47.1.1.1.1.2SnmpAdminStringread-onlycurrent
entPhysicalVendorType
OBJECT-TYPE
An indication of the vendor-specific hardware type of the physical entity. Note that this is different from the definition of MIB-II's sysObjectID. An agent should set this object to an enterprise-specific registration identifier value indicating the specific equipment type in detail. The associated instance of entPhysicalClass is used to indicate the general type of hardware device. If no vendor-specific registration identifier exists for this physical entity, or the value is unknown by this agent, then the value { 0 0 } is returned.
1.3.6.1.2.1.47.1.1.1.1.3AutonomousTyperead-onlycurrent
entPhysicalContainedIn
OBJECT-TYPE
The value of entPhysicalIndex for the physical entity that 'contains' this physical entity. A value of zero indicates this physical entity is not contained in any other physical entity. Note that the set of 'containment' relationships define a strict hierarchy; that is, recursion is not allowed. In the event that a physical entity is contained by more than one physical entity (e.g., double-wide modules), this object should identify the containing entity with the lowest value of entPhysicalIndex.
1.3.6.1.2.1.47.1.1.1.1.4PhysicalIndexOrZeroread-onlycurrent
entPhysicalClass
OBJECT-TYPE
An indication of the general hardware type of the physical entity. An agent should set this object to the standard enumeration value that most accurately indicates the general class of the physical entity, or the primary class if there is more than one entity. If no appropriate standard registration identifier exists for this physical entity, then the value 'other(1)' is returned. If the value is unknown by this agent, then the value 'unknown(2)' is returned.
1.3.6.1.2.1.47.1.1.1.1.5IANAPhysicalClassread-onlycurrent
entPhysicalParentRelPos
OBJECT-TYPE
An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as entPhysicalEntries that share the same instance values of each of the entPhysicalContainedIn and entPhysicalClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the entPhysicalContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', entPhysicalParentRelPos should have the value '3'. Note that the entPhysicalEntry for the module plugged in slot 3 should have an entPhysicalParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of entPhysicalContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an entPhysicalParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.
1.3.6.1.2.1.47.1.1.1.1.6Integer32 (-1..2147483647)read-onlycurrent
entPhysicalName
OBJECT-TYPE
The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.
1.3.6.1.2.1.47.1.1.1.1.7SnmpAdminStringread-onlycurrent
entPhysicalHardwareRev
OBJECT-TYPE
The vendor-specific hardware revision string for the physical entity. The preferred value is the hardware revision identifier actually printed on the component itself (if present). Note that if revision information is stored internally in a non-printable (e.g., binary) format, then the agent must convert such information to a printable format in an implementation-specific manner. If no specific hardware revision string is associated with the physical component, or if this information is unknown to the agent, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.8SnmpAdminStringread-onlycurrent
entPhysicalFirmwareRev
OBJECT-TYPE
The vendor-specific firmware revision string for the physical entity. Note that if revision information is stored internally in a non-printable (e.g., binary) format, then the agent must convert such information to a printable format in an implementation-specific manner. If no specific firmware programs are associated with the physical component, or if this information is unknown to the agent, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.9SnmpAdminStringread-onlycurrent
entPhysicalSoftwareRev
OBJECT-TYPE
The vendor-specific software revision string for the physical entity. Note that if revision information is stored internally in a non-printable (e.g., binary) format, then the agent must convert such information to a printable format in an implementation-specific manner. If no specific software programs are associated with the physical component, or if this information is unknown to the agent, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.10SnmpAdminStringread-onlycurrent
entPhysicalSerialNum
OBJECT-TYPE
The vendor-specific serial number string for the physical entity. The preferred value is the serial number string actually printed on the component itself (if present). On the first instantiation of a physical entity, the value of entPhysicalSerialNum associated with that entity is set to the correct vendor-assigned serial number, if this information is available to the agent. If a serial number is unknown or non-existent, the entPhysicalSerialNum will be set to a zero-length string instead. Note that implementations that can correctly identify the serial numbers of all installed physical entities do not need to provide write access to the entPhysicalSerialNum object. Agents that cannot provide non-volatile storage for the entPhysicalSerialNum strings are not required to implement write access for this object. Not every physical component will have a serial number, or even need one. Physical entities for which the associated value of the entPhysicalIsFRU object is equal to 'false(2)' (e.g., the repeater ports within a repeater module) do not need their own unique serial numbers. An agent does not have to provide write access for such entities and may return a zero-length string. If write access is implemented for an instance of entPhysicalSerialNum and a value is written into the instance, the agent must retain the supplied value in the entPhysicalSerialNum instance (associated with the same physical entity) for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those resulting in a change of the physical entity's entPhysicalIndex value.
1.3.6.1.2.1.47.1.1.1.1.11SnmpAdminString (SIZE(0..32))read-writecurrent
entPhysicalMfgName
OBJECT-TYPE
The name of the manufacturer of this physical component. The preferred value is the manufacturer name string actually printed on the component itself (if present). Note that comparisons between instances of the entPhysicalModelName, entPhysicalFirmwareRev, entPhysicalSoftwareRev, and the entPhysicalSerialNum objects are only meaningful amongst entPhysicalEntries with the same value of entPhysicalMfgName. If the manufacturer name string associated with the physical component is unknown to the agent, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.12SnmpAdminStringread-onlycurrent
entPhysicalModelName
OBJECT-TYPE
The vendor-specific model name identifier string associated with this physical component. The preferred value is the customer-visible part number, which may be printed on the component itself. If the model name string associated with the physical component is unknown to the agent, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.13SnmpAdminStringread-onlycurrent
entPhysicalAlias
OBJECT-TYPE
This object is an 'alias' name for the physical entity, as specified by a network manager, and provides a non-volatile 'handle' for the physical entity. On the first instantiation of a physical entity, the value of entPhysicalAlias associated with that entity is set to the zero-length string. However, the agent may set the value to a locally unique default value, instead of a zero-length string. If write access is implemented for an instance of entPhysicalAlias and a value is written into the instance, the agent must retain the supplied value in the entPhysicalAlias instance (associated with the same physical entity) for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those resulting in a change of the physical entity's entPhysicalIndex value.
1.3.6.1.2.1.47.1.1.1.1.14SnmpAdminString (SIZE(0..32))read-writecurrent
entPhysicalAssetID
OBJECT-TYPE
This object is a user-assigned asset tracking identifier (as specified by a network manager) for the physical entity and provides non-volatile storage of this information. On the first instantiation of a physical entity, the value of entPhysicalAssetID associated with that entity is set to the zero-length string. Not every physical component will have an asset tracking identifier or even need one. Physical entities for which the associated value of the entPhysicalIsFRU object is equal to 'false(2)' (e.g., the repeater ports within a repeater module) do not need their own unique asset tracking identifier. An agent does not have to provide write access for such entities and may instead return a zero-length string. If write access is implemented for an instance of entPhysicalAssetID and a value is written into the instance, the agent must retain the supplied value in the entPhysicalAssetID instance (associated with the same physical entity) for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those resulting in a change of the physical entity's entPhysicalIndex value. If no asset tracking information is associated with the physical component, then this object will contain a zero-length string.
1.3.6.1.2.1.47.1.1.1.1.15SnmpAdminString (SIZE(0..32))read-writecurrent
entPhysicalIsFRU
OBJECT-TYPE
This object indicates whether or not this physical entity is considered a 'field replaceable unit' by the vendor. If this object contains the value 'true(1)', then this entPhysicalEntry identifies a field replaceable unit. For all entPhysicalEntries that represent components permanently contained within a field replaceable unit, the value 'false(2)' should be returned for this object.
1.3.6.1.2.1.47.1.1.1.1.16TruthValueread-onlycurrent
entPhysicalMfgDate
OBJECT-TYPE
This object contains the date of manufacturing of the managed entity. If the manufacturing date is unknown or not supported, the object is not instantiated. The special value '0000000000000000'H may also be returned in this case.
1.3.6.1.2.1.47.1.1.1.1.17DateAndTimeread-onlycurrent
entPhysicalUris
OBJECT-TYPE
This object contains identification information about the physical entity. The object contains URIs; therefore, the syntax of this object must conform to RFC 3986, Section 3. Multiple URIs may be present and are separated by white space characters. Leading and trailing white space characters are ignored. If no URI identification information is known about the physical entity, the object is not instantiated. A zero-length octet string may also be returned in this case.
1.3.6.1.2.1.47.1.1.1.1.18OCTET STRINGread-writecurrent
entPhysicalUUID
OBJECT-TYPE
This object contains identification information about the physical entity. The object contains a Universally Unique Identifier, the syntax of this object must conform to RFC 4122, Section 4.1. A zero-length octet string is returned if no UUID information is known.
1.3.6.1.2.1.47.1.1.1.1.19UUIDorZeroread-onlycurrent
entityLogical
OBJECT-IDENTITY
1.3.6.1.2.1.47.1.2
entLogicalTable
OBJECT-TYPE
This table contains one row per logical entity. For agents that implement more than one naming scope, at least one entry must exist. Agents that instantiate all MIB objects within a single naming scope are not required to implement this table.
1.3.6.1.2.1.47.1.2.1not-accessiblecurrent
entLogicalEntry
OBJECT-TYPE
Information about a particular logical entity. Entities may be managed by this agent or other SNMP agents (possibly) in the same chassis.
1.3.6.1.2.1.47.1.2.1.1not-accessiblecurrent
entLogicalIndex
OBJECT-TYPE
The value of this object uniquely identifies the logical entity. The value should be a small positive integer; index values for different logical entities are not necessarily contiguous.
1.3.6.1.2.1.47.1.2.1.1.1Integer32 (1..2147483647)not-accessiblecurrent
entLogicalDescr
OBJECT-TYPE
A textual description of the logical entity. This object should contain a string that identifies the manufacturer's name for the logical entity and should be set to a distinct value for each version of the logical entity.
1.3.6.1.2.1.47.1.2.1.1.2SnmpAdminStringread-onlycurrent
entLogicalType
OBJECT-TYPE
An indication of the type of logical entity. This will typically be the OBJECT IDENTIFIER name of the node in the SMI's naming hierarchy that represents the major MIB module, or the majority of the MIB modules, supported by the logical entity. For example: a logical entity of a regular host/router -> mib-2 a logical entity of a 802.1d bridge -> dot1dBridge a logical entity of a 802.3 repeater -> snmpDot3RptrMgmt If an appropriate node in the SMI's naming hierarchy cannot be identified, the value 'mib-2' should be used.
1.3.6.1.2.1.47.1.2.1.1.3AutonomousTyperead-onlycurrent
entLogicalCommunity
OBJECT-TYPE
An SNMPv1 or SNMPv2c community string, which can be used to access detailed management information for this logical entity. The agent should allow read access with this community string (to an appropriate subset of all managed objects) and may also return a community string based on the privileges of the request used to read this object. Note that an agent may return a community string with read-only privileges, even if this object is accessed with a read-write community string. However, the agent must take care not to return a community string that allows more privileges than the community string used to access this object. A compliant SNMP agent may wish to conserve naming scopes by representing multiple logical entities in a single 'default' naming scope. This is possible when the logical entities, represented by the same value of entLogicalCommunity, have no object instances in common. For example, 'bridge1' and 'repeater1' may be part of the main naming scope, but at least one additional community string is needed to represent 'bridge2' and 'repeater2'. Logical entities 'bridge1' and 'repeater1' would be represented by sysOREntries associated with the 'default' naming scope. For agents not accessible via SNMPv1 or SNMPv2c, the value of this object is the empty string. This object may also contain an empty string if a community string has not yet been assigned by the agent or if no community string with suitable access rights can be returned for a particular SNMP request. Note that this object is deprecated. Agents that implement SNMPv3 access should use the entLogicalContextEngineID and entLogicalContextName objects to identify the context associated with each logical entity. SNMPv3 agents may return a zero-length string for this object or may continue to return a community string (e.g., tri-lingual agent support).
1.3.6.1.2.1.47.1.2.1.1.4OCTET STRING (SIZE(0..255))read-onlydeprecated
entLogicalTAddress
OBJECT-TYPE
The transport service address by which the logical entity receives network management traffic, formatted according to the corresponding value of entLogicalTDomain. For snmpUDPDomain, a TAddress is 6 octets long: the initial 4 octets contain the IP-address in network-byte order, and the last 2 contain the UDP port in network-byte order. Consult RFC 3417 for further information on snmpUDPDomain.
1.3.6.1.2.1.47.1.2.1.1.5TAddressread-onlycurrent
entLogicalTDomain
OBJECT-TYPE
Indicates the kind of transport service by which the logical entity receives network management traffic. Possible values for this object are presently found in RFC 3417.
1.3.6.1.2.1.47.1.2.1.1.6TDomainread-onlycurrent
entLogicalContextEngineID
OBJECT-TYPE
The authoritative contextEngineID that can be used to send an SNMP message concerning information held by this logical entity to the address specified by the associated 'entLogicalTAddress/entLogicalTDomain' pair. This object, together with the associated entLogicalContextName object, defines the context associated with a particular logical entity and allows access to SNMP engines identified by a contextEngineID and contextName pair. If no value has been configured by the agent, a zero-length string is returned, or the agent may choose not to instantiate this object at all.
1.3.6.1.2.1.47.1.2.1.1.7SnmpEngineIdOrNoneread-onlycurrent
entLogicalContextName
OBJECT-TYPE
The contextName that can be used to send an SNMP message concerning information held by this logical entity to the address specified by the associated 'entLogicalTAddress/entLogicalTDomain' pair. This object, together with the associated entLogicalContextEngineID object, defines the context associated with a particular logical entity and allows access to SNMP engines identified by a contextEngineID and contextName pair. If no value has been configured by the agent, a zero-length string is returned, or the agent may choose not to instantiate this object at all.
1.3.6.1.2.1.47.1.2.1.1.8SnmpAdminStringread-onlycurrent
entityMapping
OBJECT-IDENTITY
1.3.6.1.2.1.47.1.3
entLPMappingTable
OBJECT-TYPE
This table contains zero or more rows of logical entity to physical equipment associations. For each logical entity known by this agent, there are zero or more mappings to the physical resources, which are used to realize that logical entity. An agent should limit the number and nature of entries in this table such that only meaningful and non-redundant information is returned. For example, in a system that contains a single power supply, mappings between logical entities and the power supply are not useful and should not be included. Also, only the most appropriate physical component, which is closest to the root of a particular containment tree, should be identified in an entLPMapping entry. For example, suppose a bridge is realized on a particular module, and all ports on that module are ports on this bridge. A mapping between the bridge and the module would be useful, but additional mappings between the bridge and each of the ports on that module would be redundant (because the entPhysicalContainedIn hierarchy can provide the same information). On the other hand, if more than one bridge were utilizing ports on this module, then mappings between each bridge and the ports it used would be appropriate. Also, in the case of a single backplane repeater, a mapping for the backplane to the single repeater entity is not necessary.
1.3.6.1.2.1.47.1.3.1not-accessiblecurrent
entLPMappingEntry
OBJECT-TYPE
Information about a particular logical-entity-to-physical- equipment association. Note that the nature of the association is not specifically identified in this entry. It is expected that sufficient information exists in the MIB modules used to manage a particular logical entity to infer how physical component information is utilized.
1.3.6.1.2.1.47.1.3.1.1not-accessiblecurrent
entLPPhysicalIndex
OBJECT-TYPE
The value of this object identifies the index value of a particular entPhysicalEntry associated with the indicated entLogicalEntity.
1.3.6.1.2.1.47.1.3.1.1.1PhysicalIndexread-onlycurrent
entAliasMappingTable
OBJECT-TYPE
This table contains zero or more rows, representing mappings of logical entities and physical components to external MIB identifiers. Each physical port in the system may be associated with a mapping to an external identifier, which itself is associated with a particular logical entity's naming scope. A 'wildcard' mechanism is provided to indicate that an identifier is associated with more than one logical entity.
1.3.6.1.2.1.47.1.3.2not-accessiblecurrent
entAliasMappingEntry
OBJECT-TYPE
Information about a particular binding between a logical entity/physical component pair and an external identifier. Each logical entity/physical component pair may be associated with one alias mapping. The logical entity index may also be used as a 'wildcard' (refer to the entAliasLogicalIndexOrZero object DESCRIPTION clause for details.) Note that only entPhysicalIndex values that represent physical ports (i.e., associated entPhysicalClass value is 'port(10)') are permitted to exist in this table.
1.3.6.1.2.1.47.1.3.2.1not-accessiblecurrent
entAliasLogicalIndexOrZero
OBJECT-TYPE
The value of this object identifies the logical entity that defines the naming scope for the associated instance of the entAliasMappingIdentifier object. If this object has a non-zero value, then it identifies the logical entity named by the same value of entLogicalIndex. If this object has a value of zero, then the mapping between the physical component and the alias identifier for this entAliasMapping entry is associated with all unspecified logical entities. That is, a value of zero (the default mapping) identifies any logical entity that does not have an explicit entry in this table for a particular entPhysicalIndex/entAliasMappingIdentifier pair. For example, to indicate that a particular interface (e.g., physical component 33) is identified by the same value of ifIndex for all logical entities, the following instance might exist: entAliasMappingIdentifier.33.0 = ifIndex.5 In the event an entPhysicalEntry is associated differently for some logical entities, additional entAliasMapping entries may exist, e.g.: entAliasMappingIdentifier.33.0 = ifIndex.6 entAliasMappingIdentifier.33.4 = ifIndex.1 entAliasMappingIdentifier.33.5 = ifIndex.1 entAliasMappingIdentifier.33.10 = ifIndex.12 Note that entries with non-zero entAliasLogicalIndexOrZero index values have precedence over zero-indexed entries. In this example, all logical entities except 4, 5, and 10 associate physical entity 33 with ifIndex.6.
1.3.6.1.2.1.47.1.3.2.1.1Integer32 (0..2147483647)not-accessiblecurrent
entAliasMappingIdentifier
OBJECT-TYPE
The value of this object identifies a particular conceptual row associated with the indicated entPhysicalIndex and entLogicalIndex pair. Because only physical ports are modeled in this table, only entries that represent interfaces or ports are allowed. If an ifEntry exists on behalf of a particular physical port, then this object should identify the associated ifEntry. For repeater ports, the appropriate row in the 'rptrPortGroupTable' should be identified instead. For example, suppose a physical port was represented by entPhysicalEntry.3, entLogicalEntry.15 existed for a repeater, and entLogicalEntry.22 existed for a bridge. Then there might be two related instances of entAliasMappingIdentifier: entAliasMappingIdentifier.3.15 == rptrPortGroupIndex.5.2 entAliasMappingIdentifier.3.22 == ifIndex.17 It is possible that other mappings (besides interfaces and repeater ports) may be defined in the future, as required. Bridge ports are identified by examining the Bridge MIB and appropriate ifEntries associated with each 'dot1dBasePort' and are thus not represented in this table.
1.3.6.1.2.1.47.1.3.2.1.2RowPointerread-onlycurrent
entPhysicalContainsTable
OBJECT-TYPE
A table that exposes the container/'containee' relationships between physical entities. This table provides all the information found by constructing the virtual containment tree for a given entPhysicalTable, but in a more direct format. In the event a physical entity is contained by more than one other physical entity (e.g., double-wide modules), this table should include these additional mappings, which cannot be represented in the entPhysicalTable virtual containment tree.
1.3.6.1.2.1.47.1.3.3not-accessiblecurrent
entPhysicalContainsEntry
OBJECT-TYPE
A single container/'containee' relationship.
1.3.6.1.2.1.47.1.3.3.1not-accessiblecurrent
entPhysicalChildIndex
OBJECT-TYPE
The value of entPhysicalIndex for the contained physical entity.
1.3.6.1.2.1.47.1.3.3.1.1PhysicalIndexread-onlycurrent
entityGeneral
OBJECT-IDENTITY
1.3.6.1.2.1.47.1.4
entLastChangeTime
OBJECT-TYPE
The value of sysUpTime at the time a conceptual row is created, modified, or deleted in any of these tables: - entPhysicalTable - entLogicalTable - entLPMappingTable - entAliasMappingTable - entPhysicalContainsTable
1.3.6.1.2.1.47.1.4.1TimeStampread-onlycurrent
entityMIBTraps
OBJECT-IDENTITY
1.3.6.1.2.1.47.2
entityMIBTrapPrefix
OBJECT-IDENTITY
1.3.6.1.2.1.47.2.0
entityConformance
OBJECT-IDENTITY
1.3.6.1.2.1.47.3
entityCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.47.3.1
entityGroups
OBJECT-IDENTITY
1.3.6.1.2.1.47.3.2

Notifications

NameOIDStatus
entConfigChange
NOTIFICATION-TYPE
An entConfigChange notification is generated when the value of entLastChangeTime changes. It can be utilized by an NMS to trigger logical/physical entity table maintenance polls. An agent should not generate more than one entConfigChange 'notification-event' in a given time interval (five seconds is the suggested default). A 'notification-event' is the transmission of a single trap or inform PDU to a list of notification destinations. If additional configuration changes occur within the throttling period, then notification-events for these changes should be suppressed by the agent until the current throttling period expires. At the end of a throttling period, one notification-event should be generated if any configuration changes occurred since the start of the throttling period. In such a case, another throttling period is started right away. An NMS should periodically check the value of entLastChangeTime to detect any missed entConfigChange notification-events, e.g., due to throttling or transmission loss.
1.3.6.1.2.1.47.2.0.1current

Conformance

NameOIDStatus
entityCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement version 1 of the Entity MIB.
1.3.6.1.2.1.47.3.1.1deprecated
entity2Compliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement version 2 of the Entity MIB.
1.3.6.1.2.1.47.3.1.2deprecated
entity3Compliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement version 3 of the Entity MIB.
1.3.6.1.2.1.47.3.1.3deprecated
entity4Compliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement the full version 4 (full compliance) of the Entity MIB.
1.3.6.1.2.1.47.3.1.4current
entity4CRCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement version 4 of the Entity MIB on devices with constrained resources.
1.3.6.1.2.1.47.3.1.5current
entityPhysicalGroup
OBJECT-GROUP
The collection of objects used to represent physical system components for which a single agent provides management information.
1.3.6.1.2.1.47.3.2.1current
entityLogicalGroup
OBJECT-GROUP
The collection of objects used to represent the list of logical entities for which a single agent provides management information.
1.3.6.1.2.1.47.3.2.2deprecated
entityMappingGroup
OBJECT-GROUP
The collection of objects used to represent the associations between multiple logical entities, physical components, interfaces, and port identifiers for which a single agent provides management information.
1.3.6.1.2.1.47.3.2.3current
entityGeneralGroup
OBJECT-GROUP
The collection of objects used to represent general entity information for which a single agent provides management information.
1.3.6.1.2.1.47.3.2.4current
entityNotificationsGroup
NOTIFICATION-GROUP
The collection of notifications used to indicate Entity MIB data consistency and general status information.
1.3.6.1.2.1.47.3.2.5current
entityPhysical2Group
OBJECT-GROUP
The collection of objects used to represent physical system components for which a single agent provides management information. This group augments the objects contained in the entityPhysicalGroup.
1.3.6.1.2.1.47.3.2.6current
entityLogical2Group
OBJECT-GROUP
The collection of objects used to represent the list of logical entities for which a single SNMP entity provides management information.
1.3.6.1.2.1.47.3.2.7current
entityPhysical3Group
OBJECT-GROUP
The collection of objects used to represent physical system components for which a single agent provides management information. This group augments the objects contained in the entityPhysicalGroup.
1.3.6.1.2.1.47.3.2.8current
entityPhysical4Group
OBJECT-GROUP
The collection of objects used to represent physical system components for which a single agent provides management information. This group augments the objects contained in the entityPhysicalGroup and entityPhysicalCRGroup.
1.3.6.1.2.1.47.3.2.9current
entityPhysicalCRGroup
OBJECT-GROUP
The collection of objects used to represent physical system components for constrained resourced devices, for which a single agent provides management information.
1.3.6.1.2.1.47.3.2.10current