Description

This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measurement either represents a measured value or a SMA (Simple Moving Average) value for a specified interval rate over a period of time. This MIB module defines two tables relating to sensor measured value, including: o ceshCollectionTable - contains data describing a collection of historic data for a sensor. o ceshCollectionIntervalTable - contains zero or more rows containing historic data for a sensor The figure below illustrates the relationship between these two tables. +----------------------------------------------+ | ceshCollectionTable | | +------------------------------------------+ | | | ceshCollectionEntry | | | | entPhysicalIndex = 3 | | | | ceshCollectionIntervalTime = 60 | | | | ceshCollectionIntervals = 60 | | | | ceshCollectionInvalidIntervals = 0 |-----+ | | ceshCollectionMaxIntervals = 60 | | | | | ceshCollectionElapsedTime = 20 | | | | | ceshCollectionAlgorithm = 3 | | | | +------------------------------------------+ | | | +------------------------------------------+ | | | | ceshCollectionEntry | | | | | entPhysicalIndex = 3 | | | | | ceshCollectionIntervalTime = 3660 | | | | | ceshCollectionIntervals = 2 |------------+ | | ceshCollectionInvalidIntervals = 0 | | | | | | ceshCollectionMaxIntervals = 60 | | | | | | ceshCollectionElapsedTime = 20 | | | | | | ceshCollectionAlgorithm = 4 | | | | | +------------------------------------------+ | | | +----------------------------------------------+ | | | | +----------------------------------------------+ | | | ceshCollectionIntervalTable | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | | ceshCollectionIntervalNumber = 1 | | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | | ceshCollectionIntervalTimeStamp = 1 | | | | | +------------------------------------------+ | | | | .................... <----+ | | skipped 58 entries <----+ | | .................... <----+ | | | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | ceshCollectionIntervalNumber = 60 | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | ceshCollectionIntervalTimeStamp = 60 | | | | +------------------------------------------+ | | | | | | +------------------------------------------+ | | | | ceshCollectionIntervalEntry | | | | | entPhysicalIndex = 3 |<-----------+ | | ceshCollectionIntervalTime = 3660 | | | | ceshCollectionIntervalNumber = 1 | | | | ceshCollectionIntervalSensorValue = 54 | | | | ceshCollectionIntervalTimeStamp = 60 | | | +------------------------------------------+ | +----------------------------------------------+ If the system samples a sensor every minute for one collection and every hour for another, then the ceshCollectionTable contains two entries describing the two collections.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com

Imports

FromSymbols
CISCO-SMIciscoMgmt
ENTITY-MIBentPhysicalIndex
ENTITY-SENSOR-MIBEntitySensorValue
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-ENTITY-SENSOR-HISTORY-MIB
CISCO-SMI
ENTITY-MIB
ENTITY-SENSOR-MIB
IANA-ENTITY-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
SensorHistoryCollectionAlgorithm
TEXTUAL-CONVENTION
This textual convention denotes an enumerated integer-value that describing the method used to collect historic data for a sensor. 'other' - The implementation of the MIB module using this textual convention does not recognize the historic data collection algorithm. 'unknown' - The system is not able to ascertain the historic data collection algorithm. 'measured' - A raw value. 'simpleAverage' - The system collects a simple moving average of the values sampled from the sensor.
current

Objects

NameOIDSyntaxAccessStatus
ciscoEntitySensorHistoryMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.768.0
ceshCollectionTable
OBJECT-TYPE
This table lists each collection of historic data maintained by the system for each supported sensor. This table has an expansion dependent relationship on the ceshCollectionIntervalTable, containing zero or more rows for each corresponding collection.
1.3.6.1.4.1.9.9.768.0.1not-accessiblecurrent
ceshCollectionEntry
OBJECT-TYPE
Each entry in the ceshCollectionTable contains collection attributes describing the collection. For each supported sensor, the system creates a row for each prescribed collection. This creation process happens at startup and following the insertion of a FRU containing sensors. The system destroys a row when it destroys the corresponding row in the entPhysicalTable, which can happen as the result of the removal of the FRU containing the sensor.
1.3.6.1.4.1.9.9.768.0.1.1not-accessiblecurrent
ceshCollectionIntervalTime
OBJECT-TYPE
This object indicates the length of the sampling interval for the collection.
1.3.6.1.4.1.9.9.768.0.1.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
ceshCollectionIntervals
OBJECT-TYPE
This object indicates the number of intervals for which data has been collected.
1.3.6.1.4.1.9.9.768.0.1.1.2Gauge32read-onlycurrent
ceshCollectionInvalidIntervals
OBJECT-TYPE
This object indicates the number of intervals in the range of '0' to the value of the corresponding instance of ceshCollectionIntervals, for which no data is available. The value of this column will typically be '0', except in certain circumstances when some intervals are not available.
1.3.6.1.4.1.9.9.768.0.1.1.3Gauge32read-onlycurrent
ceshCollectionMaxIntervals
OBJECT-TYPE
This object indicates the maximum number of intervals maintained for the collection.
1.3.6.1.4.1.9.9.768.0.1.1.4Unsigned32 (0..4294967295)read-onlycurrent
ceshCollectionElapsedTime
OBJECT-TYPE
This object indicates the time that has elapsed since the beginning of the current interval.
1.3.6.1.4.1.9.9.768.0.1.1.5Gauge32read-onlycurrent
ceshCollectionAlgorithm
OBJECT-TYPE
This object indicates the algorithm used in collecting historic data from the corresponding sensor.
1.3.6.1.4.1.9.9.768.0.1.1.6SensorHistoryCollectionAlgorithmread-onlycurrent
ceshCollectionIntervalTable
OBJECT-TYPE
This table contains the historic data for each collection maintained by the system. This table has an expansion dependent relationship on the ceshCollectionTable, containing zero or more rows for each corresponding collection.
1.3.6.1.4.1.9.9.768.0.2not-accessiblecurrent
ceshCollectionIntervalEntry
OBJECT-TYPE
An entry describes the data collected for an interval. The system creates a row in the ceshCollectionIntervalTable after it has sampled a sample for a given collection. The maximum allowable entries for a collection should be less than or equal to the value specified by ceshCollectionMaxIntervals instance. Once number of entries is equal to ceshCollectionMaxIntervals, then the system destroys the lease recent row from the collection before creating a new one. An agent destroys all conceptual entries corresponding to a physical entity upon removal of the physical entity.
1.3.6.1.4.1.9.9.768.0.2.1not-accessiblecurrent
ceshCollectionIntervalNumber
OBJECT-TYPE
This object indicates the interval number identifying the interval. The interval identified by the value '1' represents the most recent interval, and the interval identified by the value (n) represents the interval immediately preceding the interval identified by the value (n-1).
1.3.6.1.4.1.9.9.768.0.2.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
ceshCollectionIntervalSensorValue
OBJECT-TYPE
This object indicates the sensor value for the corresponding physical entity during the interval. To correctly display or interpret this variable's value, you must also know the sensor's type, scale, and precision indicated by the corresponding entry in the entPhySensorTable (defined by the ENTITY-SENSOR-MIB) or entSensorValueTable (defined by the CISCO-ENTITY-SENSOR-MIB).
1.3.6.1.4.1.9.9.768.0.2.1.2EntitySensorValueread-onlycurrent
ceshCollectionIntervalTimeStamp
OBJECT-TYPE
This object indicates the value of sysUpTime when the system sampled the corresponding sensor.
1.3.6.1.4.1.9.9.768.0.2.1.3TimeStampread-onlycurrent
ciscoEntitySensorHistoryMIBConform
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.768.1
ciscoEntitySensorHistoryMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.768.1.1
ciscoEntitySensorHistoryMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.768.1.2

Conformance

NameOIDStatus
ciscoEntitySensorHistoryCompliance
MODULE-COMPLIANCE
Describes the requirements for conformance to the Entity Sensor History Collection MIB module.
1.3.6.1.4.1.9.9.768.1.1.1current
ceshCollectionGroup
OBJECT-GROUP
This group contains collection of attribute objects related to entity sensor history collection
1.3.6.1.4.1.9.9.768.1.2.1current
ceshCollectionIntervalGroup
OBJECT-GROUP
This group contains collection of interval objects related to entity sensor history collection
1.3.6.1.4.1.9.9.768.1.2.2current