MIBs Depot

CISCO-CAT6K-CROSSBAR-MIB

Registered at
1.3.6.1.4.1.9.9.217
Last updated
2013-09-16 00:00
Organization
Cisco Systems, Inc.
Revisions
2013-09-16 00:00, 2012-05-31 00:00, 2009-02-15 00:00, 2007-12-18 00:00, 2006-12-19 00:00, 2004-11-19 00:00, 2004-08-11 00:00, 2004-06-11 00:00, 2003-09-29 00:00, 2003-04-02 00:00, 2002-12-05 00:00, 2001-06-25 00:00
Namespace
cisco
Source file
CISCO-CAT6K-CROSSBAR-MIB
Digest
sha256:56f6173fd9ec525e09790bad21f37cc870e367bd61c11b863c00aaad3560a8d7

Description

The Catalyst 6000 Crossbar MIB provides instrumentation for configuration and operation of the crossbar switching fabric module, and additional functionalities for switching bus and internal bus, etc.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cat6000@cisco.com

Imports

FromSymbols
CISCO-QOS-PIB-MIBPercent
CISCO-SMIciscoMgmt
ENTITY-MIBentPhysicalDescr, entPhysicalIndex, entPhysicalName, entPhysicalVendorType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-CAT6K-CROSSBAR-MIB
CISCO-QOS-PIB-MIB
CISCO-SMI
ENTITY-MIB
IANA-ENTITY-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
ChannelStatus
TEXTUAL-CONVENTION
Status of the Channel.
current
FabricChannelNumber
TEXTUAL-CONVENTION
Fabric channel number.
current
ModuleSlotNumber
TEXTUAL-CONVENTION
Slot number of the module.
current

Objects

NameOIDSyntaxAccessStatus
ciscoCat6kXbarMIBNotifs
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.0
ciscoCat6kXbarMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1
cc6kxbarConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.1
cc6kxbarFallbackMode
OBJECT-TYPE
cc6kxbarFallbackMode controls system fallback to bus-mode after loss of switching fabric module. 'true' - When the last fabric card is removed system will adjust the supervisor and line cards switching mode automatically without resetting the system. With this feature enabled, the switch might lose traffic while it's changing the switching mode. 'false' - All the ports in the system will be disabled when the last fabric card is removed.
1.3.6.1.4.1.9.9.217.1.1.1TruthValueread-writecurrent
cc6kxbarBusOnlyModeAllowed
OBJECT-TYPE
Indicates whether bus mode is administratively enabled on the device or not.
1.3.6.1.4.1.9.9.217.1.1.2TruthValueread-writecurrent
cc6kxbarTruncatedModeAllowed
OBJECT-TYPE
Indicates whether truncated mode is administratively enabled on the device or not.
1.3.6.1.4.1.9.9.217.1.1.3TruthValueread-writecurrent
cc6kxbarMinFabricPresent
OBJECT-TYPE
This object indicates the minimum number of switching fabric capable modules to be present in the system, for any switching fabric capable module to be in 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode, when cc6kxbarTruncatedModeOper is 'false'.
1.3.6.1.4.1.9.9.217.1.1.4Unsigned32read-writecurrent
cc6kxbarLcdBannerTable
OBJECT-TYPE
cc6kxbarLcdBannerTable configures the Lcd banner of the fabric module.
1.3.6.1.4.1.9.9.217.1.1.5not-accessiblecurrent
cc6kxbarLcdBannerEntry
OBJECT-TYPE
An entry in cc6kxbarLcdBannerTable. Entries are created by the agent based on the size of the lcd banner.
1.3.6.1.4.1.9.9.217.1.1.5.1not-accessiblecurrent
cc6kxbarLcdBannerIndex
OBJECT-TYPE
Object which specifies a unique entry in the table.
1.3.6.1.4.1.9.9.217.1.1.5.1.1Unsigned32not-accessiblecurrent
cc6kxbarLcdBannerBanner
OBJECT-TYPE
Message that would be displayed on the fabric card LCD. The size of cc6kxbarLcdBannerBanner should be less than or equal to the cc6kxbarLcdBannerMaxSize value.
1.3.6.1.4.1.9.9.217.1.1.5.1.2DisplayStringread-writecurrent
cc6kxbarLcdBannerMaxSize
OBJECT-TYPE
Maximum size of the associated cc6kxbarLcdBannerBanner object.
1.3.6.1.4.1.9.9.217.1.1.5.1.3Unsigned32read-onlycurrent
cc6kxbarTruncatedModeOper
OBJECT-TYPE
Indicates if the truncated mode is operationally enabled on the device or not. 'true' - With the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for all the fabric capable modules. 'false'- With the cc6kxbarMinFabricPresent fabric capable modules and the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for fabric capable modules.
1.3.6.1.4.1.9.9.217.1.1.6TruthValueread-onlycurrent
cc6kxbarDcefOnlyModeAllowed
OBJECT-TYPE
Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode.
1.3.6.1.4.1.9.9.217.1.1.7TruthValueread-writecurrent
cc6kxbarForceBusMode
OBJECT-TYPE
Indicates whether some affected modules are forced to be in 'busmode' or not. 'true' - Setting cc6kxbarForceBusMode to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to 'busmode'. Changing the cc6kxbarForceBusMode to 'true' will make all the affected modules reloaded and booted up as non fabric capable modules. 'false'- Setting cc6kxbarForceBusMode to 'false' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to the default value. Changing cc6kxbarForceBusMode to 'false' will make all the affected modules reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode.
1.3.6.1.4.1.9.9.217.1.1.8TruthValueread-writecurrent
cc6kxbarBusOnlyModeOper
OBJECT-TYPE
Indicates if the bus mode is operationally enabled on the device or not. 'true' - Modules are allowed to run in 'busmode'. 'false' - None of the modules are allowed to run in 'busmode' i.e., All the non-fabric capable modules will be powered off. Absence of fabric module results in all the fabric capable modules being powered off.
1.3.6.1.4.1.9.9.217.1.1.9TruthValueread-onlycurrent
cc6kxbarStatus
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.2
cc6kxbarFabricActiveSlot
OBJECT-TYPE
cc6kxbarFabricActiveSlot indicates the slot number of the active switching fabric module. A value of zero indicates that the active switching fabric module is either powered down or not present in the chassis.
1.3.6.1.4.1.9.9.217.1.2.1ModuleSlotNumberread-onlycurrent
cc6kxbarFabricBackupSlot
OBJECT-TYPE
cc6kxbarFabricBackupSlot indicates the slot number of the backup switching fabric module. A value of zero indicates that the backup switching fabric module is either powered down or not present in the chassis.
1.3.6.1.4.1.9.9.217.1.2.2ModuleSlotNumberread-onlycurrent
cc6kxbarModuleModeTable
OBJECT-TYPE
cc6kxbarModuleModeTable indicates the switching mode of each module in the system.
1.3.6.1.4.1.9.9.217.1.2.3not-accessiblecurrent
cc6kxbarModuleModeEntry
OBJECT-TYPE
An entry in cc6kxbarModuleModeTable. The agent creates an entry when a non switching fabric module is inserted in the chassis. The agent destroys an entry when a non switching fabric module is power down or reset or removed from the chassis.
1.3.6.1.4.1.9.9.217.1.2.3.1not-accessiblecurrent
cc6kxbarModuleModeModule
OBJECT-TYPE
The module slot number.
1.3.6.1.4.1.9.9.217.1.2.3.1.1ModuleSlotNumbernot-accessiblecurrent
cc6kxbarModuleModeSwitchingMode
OBJECT-TYPE
cc6kxbarModuleModeSwitchingMode indicates switching mode of the cc6kxbarModuleModeModule. 'busmode' - Modules in this mode don't use fabric. Backplane is used for both lookup and data forwarding. 'crossbarmode' - Modules in this mode use backplane for forwarding decision and fabric for data forwarding 'dcefmode' - Modules in this mode use fabric for data forwarding and local forwarding is enabled.
1.3.6.1.4.1.9.9.217.1.2.3.1.2INTEGER {busmode(1), crossbarmode(2), dcefmode(3)}read-onlycurrent
cc6kxbarModuleChannelTable
OBJECT-TYPE
cc6kxbarModuleChannelTable shows the operational status of fabric channels. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero.
1.3.6.1.4.1.9.9.217.1.2.4not-accessiblecurrent
cc6kxbarModuleChannelEntry
OBJECT-TYPE
An entry in cc6kxbarModuleChannelTable.
1.3.6.1.4.1.9.9.217.1.2.4.1not-accessiblecurrent
cc6kxbarModuleChannelModule
OBJECT-TYPE
The module slot number.
1.3.6.1.4.1.9.9.217.1.2.4.1.1ModuleSlotNumbernot-accessiblecurrent
cc6kxbarModuleChannelChannel
OBJECT-TYPE
Fabric channel number of the cc6kxbarModuleChannelModule.
1.3.6.1.4.1.9.9.217.1.2.4.1.2FabricChannelNumbernot-accessiblecurrent
cc6kxbarModuleChannelModStatus
OBJECT-TYPE
The status of the fabric channel at the cc6kxbarModuleChannelModule.
1.3.6.1.4.1.9.9.217.1.2.4.1.3ChannelStatusread-onlycurrent
cc6kxbarModuleChannelFabStatus
OBJECT-TYPE
The status of the fabric channel at the cc6kxbarFabricActiveSlot.
1.3.6.1.4.1.9.9.217.1.2.4.1.4ChannelStatusread-onlycurrent
cc6kxbarModuleChannelSpeed
OBJECT-TYPE
The speed in mega bits per second of the cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule.
1.3.6.1.4.1.9.9.217.1.2.4.1.5Gauge32read-onlycurrent
cc6kxbarStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.3
cc6kxbarStatisticsTable
OBJECT-TYPE
cc6kxbarStatisticsTable gives the fabric channel counters and utilization information. This table will be instantiated when cc6kxbarFabricActiveSlot has a valid value other than zero.
1.3.6.1.4.1.9.9.217.1.3.1not-accessiblecurrent
cc6kxbarStatisticsEntry
OBJECT-TYPE
An entry in cc6kxbarStatisticsTable.
1.3.6.1.4.1.9.9.217.1.3.1.1not-accessiblecurrent
cc6kxbarStatisticsModule
OBJECT-TYPE
The module slot number.
1.3.6.1.4.1.9.9.217.1.3.1.1.1ModuleSlotNumbernot-accessiblecurrent
cc6kxbarStatisticsChannel
OBJECT-TYPE
Fabric channel number associated with the cc6kxbarStatisticsModule.
1.3.6.1.4.1.9.9.217.1.3.1.1.2FabricChannelNumbernot-accessiblecurrent
cc6kxbarStatisticsInErrors
OBJECT-TYPE
The total number of error packets received on cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized.
1.3.6.1.4.1.9.9.217.1.3.1.1.3Counter32read-onlycurrent
cc6kxbarStatisticsOutErrors
OBJECT-TYPE
The total number of error packets transmitted on cc6kxbarStatisticsModule through the cc6kxbarStatisticsChannel since this entry was last initialized.
1.3.6.1.4.1.9.9.217.1.3.1.1.4Counter32read-onlycurrent
cc6kxbarStatisticsOutDropped
OBJECT-TYPE
The total number of dropped packets transmitted on the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized.
1.3.6.1.4.1.9.9.217.1.3.1.1.5Counter32read-onlycurrent
cc6kxbarStatisticsInUtil
OBJECT-TYPE
Input utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.
1.3.6.1.4.1.9.9.217.1.3.1.1.6Percentread-onlycurrent
cc6kxbarStatisticsOutUtil
OBJECT-TYPE
Output utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.
1.3.6.1.4.1.9.9.217.1.3.1.1.7Percentread-onlycurrent
cc6kxbarStatisticsPeakInUtil
OBJECT-TYPE
Indicates the peak value of cc6kxbarStatisticsInUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.
1.3.6.1.4.1.9.9.217.1.3.1.1.8Percentread-onlycurrent
cc6kxbarStatisticsPeakTmInUtil
OBJECT-TYPE
Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakInUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakInUtil is '0'.
1.3.6.1.4.1.9.9.217.1.3.1.1.9DateAndTimeread-onlycurrent
cc6kxbarStatisticsPeakOutUtil
OBJECT-TYPE
Indicates the peak value of cc6kxbarStatisticsOutUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.
1.3.6.1.4.1.9.9.217.1.3.1.1.10Percentread-onlycurrent
cc6kxbarStatisticsPeakTmOutUtil
OBJECT-TYPE
Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakOutUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakOutUtil is '0'.
1.3.6.1.4.1.9.9.217.1.3.1.1.11DateAndTimeread-onlycurrent
cc6kxbarStatisticsLbusDrops
OBJECT-TYPE
This object indicates the number of packets that have been deterministically dropped due to the threshold on the local bus FIFO, errors and exception conditions.
1.3.6.1.4.1.9.9.217.1.3.1.1.12Counter32read-onlycurrent
cc6kxbarErrorTable
OBJECT-TYPE
cc6kxbarErrorTable provides the fabric channel error information. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero.
1.3.6.1.4.1.9.9.217.1.3.2not-accessiblecurrent
cc6kxbarErrorEntry
OBJECT-TYPE
An entry in cc6kxbarErrorTable for a specific fabric channel on a specific module.
1.3.6.1.4.1.9.9.217.1.3.2.1not-accessiblecurrent
cc6kxbarErrorModule
OBJECT-TYPE
The module slot number.
1.3.6.1.4.1.9.9.217.1.3.2.1.1ModuleSlotNumbernot-accessiblecurrent
cc6kxbarErrorChannel
OBJECT-TYPE
Fabric channel number associated with the cc6kxbarErrorModule.
1.3.6.1.4.1.9.9.217.1.3.2.1.2FabricChannelNumbernot-accessiblecurrent
cc6kxbarErrorModuleCrc
OBJECT-TYPE
Indicates the total number of CRC error packets for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.
1.3.6.1.4.1.9.9.217.1.3.2.1.3Gauge32read-onlycurrent
cc6kxbarErrorModuleHbeat
OBJECT-TYPE
Indicates the total number of heartbeat misses detected for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.
1.3.6.1.4.1.9.9.217.1.3.2.1.4Gauge32read-onlycurrent
cc6kxbarErrorModuleSync
OBJECT-TYPE
Indicates the total number of times cc6kxbarErrorModule could not sync to the active switching fabric module.
1.3.6.1.4.1.9.9.217.1.3.2.1.5Gauge32read-onlycurrent
cc6kxbarErrorModuleDDRSync
OBJECT-TYPE
Indicates the total number of DDR(Double Data Rate) channel sync errors for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.
1.3.6.1.4.1.9.9.217.1.3.2.1.6Gauge32read-onlycurrent
cc6kxbarErrorChannelSync
OBJECT-TYPE
Indicates the total number of sync errors received at cc6kxbarErrorChannel.
1.3.6.1.4.1.9.9.217.1.3.2.1.7Gauge32read-onlycurrent
cc6kxbarErrorChannelBuffer
OBJECT-TYPE
Indicates the total number of times the memory buffer for cc6kxbarErrorChannel of the cc6kxbarErrorModule is full.
1.3.6.1.4.1.9.9.217.1.3.2.1.8Gauge32read-onlycurrent
cc6kxbarErrorChannelTimeout
OBJECT-TYPE
Indicates the total number of timeouts for input from the cc6kxbarErrorChannel of the cc6kxbarErrorModule.
1.3.6.1.4.1.9.9.217.1.3.2.1.9Gauge32read-onlycurrent
cc6kxbarSwBusObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.4
cc6kxbarSwBusSwitchingStatus
OBJECT-TYPE
Indicates the current switching status of the switching bus on the system. normal -- the switching bus is under normal packet switching operation. stalled -- the switching bus has stopped packet switching but is still attached to the system, i.e., the switching bus is stalled. isolated -- the switching bus has stopped packet switching and is detached from the system, i.e., the switching bus is isolated. The object is only instantiated on systems which support switching bus switching detection feature.
1.3.6.1.4.1.9.9.217.1.4.1INTEGER {normal(1), stalled(2), isolated(3)}read-onlycurrent
cc6kxbarSwBusFailureDuration
OBJECT-TYPE
Indicates the failure duration of the switching bus since the switching bus has transitioned out of the normal(1) state as monitored by cc6kxbarSwBusSwitchingStatus. If the object value of cc6kxbarSwBusSwitchingStatus is normal(1), then the object value of cc6kxbarSwBusFailureDuration should be zero. The object is only instantiated on systems which support switching bus switching detection feature.
1.3.6.1.4.1.9.9.217.1.4.2Unsigned32read-onlycurrent
cc6kxbarSwBusNotifEnable
OBJECT-TYPE
Indicates whether or not the notification cc6kxbarSwBusStatusChangeNotif should be generated when there is change in the switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus. The object is only instantiated on systems which support switching bus switching detection feature.
1.3.6.1.4.1.9.9.217.1.4.3TruthValueread-writecurrent
cc6kxbarSwBusUtilization
OBJECT-TYPE
Indicates the percentage of bandwidth utilization of the switching bus.
1.3.6.1.4.1.9.9.217.1.4.4Percentread-onlycurrent
cc6kxbarSwBusPeakUtilization
OBJECT-TYPE
Indicates the peak percentage value of bandwidth utilization of the switching bus since the system started.
1.3.6.1.4.1.9.9.217.1.4.5Percentread-onlycurrent
cc6kxbarSwBusPeakTimeUtil
OBJECT-TYPE
Indicates the time at which the peak percentage value of bandwidth utilization of the switching bus value occurred.
1.3.6.1.4.1.9.9.217.1.4.6DateAndTimeread-onlycurrent
cc6kxbarIntBusObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.5
cc6kxbarIntBusNotifEnable
OBJECT-TYPE
Indicates whether the generation of a specified notification for internal bus is enabled or not. If a bit corresponding to a notification is set to 1, then that notification can be generated. intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif notification. intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif notification.
1.3.6.1.4.1.9.9.217.1.5.1Bits {intBusCRCErrExcd(0), intBusCRCErrRcvrd(1)}read-writecurrent
cc6kxbarIntBusCRCErrTable
OBJECT-TYPE
A table containing internal bus CRC error information on a list of physical entities (such as modules).
1.3.6.1.4.1.9.9.217.1.5.2not-accessiblecurrent
cc6kxbarIntBusCRCErrEntry
OBJECT-TYPE
An entry containing internal bus CRC error information on a physical entity (such as a module).
1.3.6.1.4.1.9.9.217.1.5.2.1not-accessiblecurrent
cc6kxbarIntBusCRCErrExcdStatus
OBJECT-TYPE
Indicates whether the internal bus CRC error on a physical entity is currently exceeding the fatal threshold or not.
1.3.6.1.4.1.9.9.217.1.5.2.1.1TruthValueread-onlycurrent
cc6kxbarIntBusCRCErrExcdCount
OBJECT-TYPE
Indicates the number of times the internal bus CRC error on a physical entity has exceeded the fatal threshold.
1.3.6.1.4.1.9.9.217.1.5.2.1.2Unsigned32read-onlycurrent
cc6kxbarFlowCtrlObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.6
cc6kxbarFlowCtrlNotifEnable
OBJECT-TYPE
Specifies whether the generation of a specified notification for flow control feature is enabled or not. If a bit corresponding to a notification is set to one, then that notification can be generated. busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif notification.
1.3.6.1.4.1.9.9.217.1.6.1Bits {busThreshExcd(0)}read-writecurrent
cc6kxbarFlowCtrlBusFIFOThrMode
OBJECT-TYPE
Specifies the mode configuration of the system bus flow control FIFO threshold. off -- the flow control FIFO threshold is set to the original value defined by the system. on -- the flow control FIFO threshold is set to the lower value defined by the system. auto -- the system starts monitoring the system bus flow control FIFO threshold and will change the flow control FIFO threshold from the original value to the lower value when the system detects the first occurrence of the threshold exceeding on a physical entity (such as a module) over the system allowed limit.
1.3.6.1.4.1.9.9.217.1.6.2INTEGER {off(1), on(2), auto(3)}read-writecurrent
cc6kxbarFlowCtrlBusFIFOThrValue
OBJECT-TYPE
Indicates the current value of the system bus flow control FIFO threshold, whether it is the original value or the lower value.
1.3.6.1.4.1.9.9.217.1.6.3INTEGER {original(1), lower(2)}read-onlycurrent
cc6kxbarFlowCtrlBusFIFOTransTime
OBJECT-TYPE
Indicates the value of sysUpTime at the time that the system bus flow control FIFO threshold is transitioned to lower value when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This object will take on the value of zero when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'original'.
1.3.6.1.4.1.9.9.217.1.6.4TimeStampread-onlycurrent
cc6kxbarSystemCapacityObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.7
cc6kxbarSysCapPfcOperMode
OBJECT-TYPE
Indicates the operating mode of the policy feature card (PFC). unknown -- unknown. pfc3a -- Policy feature card 3A. pfc3b -- Policy feature card 3B. pfc3bxl -- Policy feature card 3B XL. pfc3cst1 -- Policy feature card 3C ST1. pfc3cxlst1 -- Policy feature card 3C XL ST1. pfc3c -- Policy feature card 3C. pfc3cxl -- Policy feature card 3C XL. pfc4 -- Policy feature card 4. pfc4xl -- Policy feature card 4 XL. pfc4xxl -- Policy feature card 4 XXL. pfc4lite -- Policy feature card 4 Lite.
1.3.6.1.4.1.9.9.217.1.7.1INTEGER {unknown(1), pfc3a(2), pfc3b(3), pfc3bxl(4), pfc3cst1(5), pfc3cxlst1(6), pfc3c(7), pfc3cxl(8), pfc4(9), pfc4xl(10), pfc4xxl(11), pfc4lite(12)}read-onlycurrent
cc6kxbarSysCapSwitchResTable
OBJECT-TYPE
A cc6kxbarSysCapSwitchResTable entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9).
1.3.6.1.4.1.9.9.217.1.7.2not-accessiblecurrent
cc6kxbarSysCapSwitchResEntry
OBJECT-TYPE
A cc6kxbarSysCapSwitchResEntry entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9). Entries are created by the agent at the system power-up or module insertion. Entries are deleted by the agent upon module removal.
1.3.6.1.4.1.9.9.217.1.7.2.1not-accessiblecurrent
cc6kxbarSysCapSwitchResSeries
OBJECT-TYPE
Indicates the module series for traffic forwarding options. unknown -- unknown. supervisor -- supervisor module. classic -- classic module. fabric -- fabric module. dcef720 -- dCEF720 module. cef720 -- CEF720 module. dcef256 -- dCEF256 module. cef256 -- CEF256 module.
1.3.6.1.4.1.9.9.217.1.7.2.1.1INTEGER {unknown(1), supervisor(2), classic(3), fabric(4), dcef720(5), cef720(6), dcef256(7), cef256(8)}read-onlycurrent
cc6kxbarSysCapSwitchResCefMode
OBJECT-TYPE
Indicates the Cisco Express Forwarding (CEF) mode of the module. notApplicable -- not applicable for this module. dcef -- distributed CEF. cef -- CEF.
1.3.6.1.4.1.9.9.217.1.7.2.1.2INTEGER {notApplicable(1), dcef(2), cef(3)}read-onlycurrent
cc6kxbarErrorRecoveryObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.8
cc6kxbarErrRcvrySwitchoverEnable
OBJECT-TYPE
Specifies whether the switchover to the standby fabric module is enabled or not on the detection of excessive fabric link errors occurring in a channel for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.1.8.3TruthValueread-writecurrent
cc6kxbarErrRcvryPersLinkResync
OBJECT-TYPE
Specifies whether the system will resync the channel or not on the detection of excessive persistent fabric link errors in a channel for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.1.8.4TruthValueread-writecurrent
cc6kxbarErrRcvryChResyncCount
OBJECT-TYPE
Specifies the consecutive number of times of channel resync within the time interval as specified by cc6kxbarErrRcvryChResyncInterval, over which the channel resync is considered as failure for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.1.8.5Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarErrRcvryChResyncInterval
OBJECT-TYPE
Specifies the time interval for the consecutive counting of channel resync for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.1.8.6Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarTrafficMonitorObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.9
cc6kxbarTrafficMonitorSwBusObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.9.1
cc6kxbarTMSwBusUtilEnable
OBJECT-TYPE
Specifies whether the traffic monitor feature is enabled on the switching bus or not.
1.3.6.1.4.1.9.9.217.1.9.1.1TruthValueread-writecurrent
cc6kxbarTMSwBusUtilInterval
OBJECT-TYPE
Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold.
1.3.6.1.4.1.9.9.217.1.9.1.2Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarTMSwBusUtilThreshold
OBJECT-TYPE
Specifies the threshold of the switching bus traffic utilization.
1.3.6.1.4.1.9.9.217.1.9.1.3Percentread-writecurrent
cc6kxbarTMSwBusUtilLogCount
OBJECT-TYPE
Indicates the number of times the following events are logged for the switching bus: 1. the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). 2. the switching bus traffic utilization has fallen below the configured threshold.
1.3.6.1.4.1.9.9.217.1.9.1.4Counter32read-onlycurrent
cc6kxbarTMSwBusUtilLastLogTime
OBJECT-TYPE
Indicates the last logging time of the events as counted in cc6kxbarTMSwBusUtilLogCount. This object will contain 0-1-1,00:00:00.0 when the value of cc6kxbarTMSwBusUtilLogCount is zero.
1.3.6.1.4.1.9.9.217.1.9.1.5DateAndTimeread-onlycurrent
cc6kxbarTMSwBusUtilLogInterval
OBJECT-TYPE
Specifies the logging interval if the switching bus traffic utilization keeps staying above the cc6kxbarTMSwBusUtilThreshold.
1.3.6.1.4.1.9.9.217.1.9.1.6Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarTMSwBusUtilUtilization
OBJECT-TYPE
The switching bus traffic utilization included in the notification currently being sent.
1.3.6.1.4.1.9.9.217.1.9.1.7Percentaccessible-for-notifycurrent
cc6kxbarTMSwBusUtilNotifEnable
OBJECT-TYPE
Specifies whether the generation of c6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is disabled.
1.3.6.1.4.1.9.9.217.1.9.1.8TruthValueread-writecurrent
cc6kxbarTrafficMonitorChObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.1.9.2
cc6kxbarTMChUtilTable
OBJECT-TYPE
cc6kxbarTrafficMntrChUtilTable provides the information on the traffic utilization of each fabric channel associated with each module slot for a given traffic direction in the chassis.
1.3.6.1.4.1.9.9.217.1.9.2.1not-accessiblecurrent
cc6kxbarTMChUtilEntry
OBJECT-TYPE
An entry in cc6kxbarTMChUtilTable. Each traffic direction for each fabric channel associated with each module slot in the chassis will have an entry in this table.
1.3.6.1.4.1.9.9.217.1.9.2.1.1not-accessiblecurrent
cc6kxbarTMChUtilModule
OBJECT-TYPE
Indicates the module slot number in the chassis.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.1ModuleSlotNumbernot-accessiblecurrent
cc6kxbarTMChUtilChannel
OBJECT-TYPE
Indicates the fabric channel number associated with the corresponding cc6kxbarTMChUtilModule.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.2FabricChannelNumbernot-accessiblecurrent
cc6kxbarTMChUtilDirection
OBJECT-TYPE
Indicates the direction of traffic to be monitored.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.3INTEGER {ingress(1), egress(2)}not-accessiblecurrent
cc6kxbarTMChUtilEnable
OBJECT-TYPE
Specifies whether the traffic monitor feature is enabled on a fabric channel for a given traffic direction or not.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.4TruthValueread-writecurrent
cc6kxbarTMChUtilInterval
OBJECT-TYPE
Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.5Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarTMChUtilThreshold
OBJECT-TYPE
Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.6Percentread-writecurrent
cc6kxbarTMChUtilLogCount
OBJECT-TYPE
Indicates the number of times the following events are logged on a fabric channel for a given direction. 1. the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). 2. the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.7Counter32read-onlycurrent
cc6kxbarTMChUtilLastLogTime
OBJECT-TYPE
Indicates the last logging time of the events as counted in the corresponding cc6kxbarTMChUtilLogCount on a fabric channel for a given traffic direction. This object will contain 0-1-1,00:00:00.0 when the corresponding cc6kxbarTMChUtilLogCount is zero.
1.3.6.1.4.1.9.9.217.1.9.2.1.1.8DateAndTimeread-onlycurrent
cc6kxbarTMChUtilLogInterval
OBJECT-TYPE
Specifies the logging interval if the traffic utilization for a fabric channel on a given traffic direction keeps staying above its corresponding cc6kxbarTMChUtilThreshold.
1.3.6.1.4.1.9.9.217.1.9.2.2Unsigned32 (1..4294967295)read-writecurrent
cc6kxbarTMChUtilUtilization
OBJECT-TYPE
The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent.
1.3.6.1.4.1.9.9.217.1.9.2.3Percentaccessible-for-notifycurrent
cc6kxbarTMChUtilNotifEnable
OBJECT-TYPE
Specifies whether the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is disabled.
1.3.6.1.4.1.9.9.217.1.9.2.4TruthValueread-writecurrent
cc6kxbarMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.3
cc6kxbarMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.3.1
cc6kxbarMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.217.3.2

Notifications

NameOIDStatus
cc6kxbarSwBusStatusChangeNotif
NOTIFICATION-TYPE
A cc6kxbarSwBusStatusChangeNotif notification is sent by the device when there is change in switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus.
1.3.6.1.4.1.9.9.217.0.1current
cc6kxbarIntBusCRCErrExcdNotif
NOTIFICATION-TYPE
A cc6kxbarIntBusCRCThreshExcdNotif notification is sent by the system when the system has detected that the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has exceeded the fatal threshold.
1.3.6.1.4.1.9.9.217.0.2current
cc6kxbarIntBusCRCErrRcvrdNotif
NOTIFICATION-TYPE
A cc6kxbarIntBusCRCErrRcvrdNotif notification is sent by the system when the system has recovered as the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has fallen below the normal threshold.
1.3.6.1.4.1.9.9.217.0.3current
cc6kxbarFlowCtrlBusThrExcdNotif
NOTIFICATION-TYPE
A cc6kxbarFlowCtrlBusThrExcdNotif notification is sent by the system when the system detects the first occurrence of the system bus flow control FIFO threshold exceeding on a physical entity (such as a module) over the system allowed limit when the object value of cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'.
1.3.6.1.4.1.9.9.217.0.4current
cc6kxbarTMSwBusUtilAboveNotif
NOTIFICATION-TYPE
This notification is sent when the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilAboveNotif is sent.
1.3.6.1.4.1.9.9.217.0.5current
cc6kxbarTMSwBusUtilBelowNotif
NOTIFICATION-TYPE
This notification is sent when the switching bus traffic utilization has fallen below the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilBelowNotif is sent.
1.3.6.1.4.1.9.9.217.0.6current
cc6kxbarTMChUtilAboveNotif
NOTIFICATION-TYPE
This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilAboveNotif is sent.
1.3.6.1.4.1.9.9.217.0.7current
cc6kxbarTMChUtilBelowNotif
NOTIFICATION-TYPE
This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilBelowNotif is sent.
1.3.6.1.4.1.9.9.217.0.8current

Conformance

NameOIDStatus
cc6kxbarMIBCompliance
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.2deprecated
cc6kxbarMIBComplianceVer1
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.3deprecated
cc6kxbarMIBComplianceVer2
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.4deprecated
cc6kxbarMIBComplianceVer3
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.5deprecated
cc6kxbarMIBComplianceVer4
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.6deprecated
cc6kxbarMIBComplianceVer5
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.7deprecated
cc6kxbarMIBComplianceVer6
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.8deprecated
cc6kxbarMIBComplianceVer7
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.9deprecated
cc6kxbarMIBComplianceVer8
MODULE-COMPLIANCE
The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB.
1.3.6.1.4.1.9.9.217.3.1.10current
cc6kxbarModuleStatusGroup
OBJECT-GROUP
A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module. cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1.
1.3.6.1.4.1.9.9.217.3.2.1deprecated
cc6kxbarChannelStatusGroup
OBJECT-GROUP
A collection of objects providing status and configuration of the fabric channel.
1.3.6.1.4.1.9.9.217.3.2.2current
cc6kxbarChannelStatisticsGroup
OBJECT-GROUP
A collection of objects providing statistics for the fabric channel. cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1.
1.3.6.1.4.1.9.9.217.3.2.3deprecated
cc6kxbarFallbackGroup
OBJECT-GROUP
This object controls system fallback to bus-mode after loss of switching fabric module.
1.3.6.1.4.1.9.9.217.3.2.4current
cc6kxbarBusOnlyAllowedGroup
OBJECT-GROUP
This object determines the value of cc6kxbarModuleModeSwitchingMode of each module.
1.3.6.1.4.1.9.9.217.3.2.5current
cc6kxbarModuleStatusGroupVer1
OBJECT-GROUP
A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module.
1.3.6.1.4.1.9.9.217.3.2.6current
cc6kxbarChannelStatisticsGroupVer1
OBJECT-GROUP
A collection of objects providing statistics for the fabric channel.
1.3.6.1.4.1.9.9.217.3.2.7current
cc6kxbarLcdBannerGroup
OBJECT-GROUP
A collection of objects providing configuration of the lcd Banner of the fabric module.
1.3.6.1.4.1.9.9.217.3.2.8current
cc6kxbarChannelUtilGroup
OBJECT-GROUP
These object determines Input and Output Utilization of the fabric channel.
1.3.6.1.4.1.9.9.217.3.2.9current
cc6kxbarChannelSpeedGroup
OBJECT-GROUP
A collection of objects providing the speed of the fabric channel.
1.3.6.1.4.1.9.9.217.3.2.10current
cc6kxbarSwBusGroup
OBJECT-GROUP
A collection of objects for the switching bus switching detection feature.
1.3.6.1.4.1.9.9.217.3.2.11current
cc6kxbarSwBusNotifGroup
NOTIFICATION-GROUP
A collection of notifications for the switching bus switching detection feature.
1.3.6.1.4.1.9.9.217.3.2.12current
cc6kxbarTruncatedOperGroup
OBJECT-GROUP
A collection of objects providing the operational truncated mode.
1.3.6.1.4.1.9.9.217.3.2.13current
cc6kxbarIntBusNotifControlGroup
OBJECT-GROUP
A collection of objects to control the notification generation for internal bus.
1.3.6.1.4.1.9.9.217.3.2.14current
cc6kxbarIntBusCRCErrNotifGroup
NOTIFICATION-GROUP
A collection of notifications for the internal bus CRC error.
1.3.6.1.4.1.9.9.217.3.2.15current
cc6kxbarIntBusCRCErrGroup
OBJECT-GROUP
A collection of objects to indicate the internal bus CRC error information on a physical entity.
1.3.6.1.4.1.9.9.217.3.2.16current
cc6kxbarDcefOnlyModeAllowedGroup
OBJECT-GROUP
A collection of objects providing the configuration and information about the dcef only mode feature.
1.3.6.1.4.1.9.9.217.3.2.17current
cc6kxbarForceBusModeGroup
OBJECT-GROUP
A collection of objects providing the configuration and information about the force bus mode feature.
1.3.6.1.4.1.9.9.217.3.2.18current
cc6kxbarFlowCtrlNotifCtrlGroup
OBJECT-GROUP
A collection of objects to control the notification generation for the system flow control feature.
1.3.6.1.4.1.9.9.217.3.2.19current
cc6kxbarFlowCtrlBusThreshGroup
OBJECT-GROUP
A collection of objects providing configuration information about the system bus flow control FIFO threshold.
1.3.6.1.4.1.9.9.217.3.2.20current
cc6kxbarFlowCtrlBusThrNotifGroup
NOTIFICATION-GROUP
A collection of notifications for the system bus flow control FIFO threshold exceeding.
1.3.6.1.4.1.9.9.217.3.2.21current
cc6kxbarBusOnlyModeOperGroup
OBJECT-GROUP
A collection of objects providing the operational bus mode.
1.3.6.1.4.1.9.9.217.3.2.22current
cc6kxbarSysCapPfcOperModeGroup
OBJECT-GROUP
A collection of objects providing the system information of PFC operational mode.
1.3.6.1.4.1.9.9.217.3.2.23current
cc6kxbarSysCapSwitchResGroup
OBJECT-GROUP
A collection of objects providing the capacity information of switching resources in the system.
1.3.6.1.4.1.9.9.217.3.2.24current
cc6kxbarChannelUtilGroup1
OBJECT-GROUP
A collection of objects providing the information about peak input and output utilization of a specific fabric channel on a specific module.
1.3.6.1.4.1.9.9.217.3.2.25current
cc6kxbarSwBusGroup1
OBJECT-GROUP
A collection of objects providing the information about switching bus utilization.
1.3.6.1.4.1.9.9.217.3.2.26current
cc6kxbarErrorGroup
OBJECT-GROUP
A collection of objects providing error statistics for a specific fabric channel on a specific module.
1.3.6.1.4.1.9.9.217.3.2.27current
cc6kxbarErrRcvryThresholdGroup
OBJECT-GROUP
A collection of objects providing the configuration of thresholds on fabric link errors for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.3.2.28current
cc6kxbarErrRcvrySwitchoverGroup
OBJECT-GROUP
A collection of objects providing the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.3.2.29current
cc6kxbarErrRcvryPersLinkResGroup
OBJECT-GROUP
A collection of objects providing the configuration of channel resync on excessive persistent fabric link errors for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.3.2.30current
cc6kxbarErrRcvryChResyncGroup
OBJECT-GROUP
A collection of objects providing the configuration for channel resync threshold for the fabric error recovery feature.
1.3.6.1.4.1.9.9.217.3.2.31current
cc6kxbarTMSwBusUtilGroup
OBJECT-GROUP
A collection of objects providing configuration information for traffic monitor feature on the switching bus.
1.3.6.1.4.1.9.9.217.3.2.32current
cc6kxbarTMSwBusUtilNotifControlGroup
OBJECT-GROUP
A collection of objects to control the traffic monitor notification generation on the switching bus.
1.3.6.1.4.1.9.9.217.3.2.33current
cc6kxbarTMSwBusUtilNotifObjectGroup
OBJECT-GROUP
A collection of objects included in the traffic monitor notifications on the switching bus.
1.3.6.1.4.1.9.9.217.3.2.34current
cc6kxbarTMSwBusUtilNotifGroup
NOTIFICATION-GROUP
A collection of traffic monitor notifications on the switching bus.
1.3.6.1.4.1.9.9.217.3.2.35current
cc6kxbarTMChUtilGroup
OBJECT-GROUP
A collection of objects providing the configuration information for traffic monitor feature on fabric channels.
1.3.6.1.4.1.9.9.217.3.2.36current
cc6kxbarTMChUtilNotifControlGroup
OBJECT-GROUP
A collection of objects to control the traffic monitor notification generation on fabric channels.
1.3.6.1.4.1.9.9.217.3.2.37current
cc6kxbarTMChUtilNotifObjectGroup
OBJECT-GROUP
A collection of objects included in the traffic monitor notifications on fabric channels.
1.3.6.1.4.1.9.9.217.3.2.38current
cc6kxbarTMChUtilNotifGroup
NOTIFICATION-GROUP
A collection of traffic monitor notifications on fabric channels.
1.3.6.1.4.1.9.9.217.3.2.39current
cc6kxbarStatisticsLbusDropGroup
OBJECT-GROUP
A collection of objects providing information for local bus drop packets statistics.
1.3.6.1.4.1.9.9.217.3.2.40current