CISCO-CAT6K-CROSSBAR-MIB
- Registered at
- 1.3.6.1.4.1.9.9.217
- Last updated
- 2013-09-16 00:00
- Organization
- Cisco Systems, Inc.
- Revisions
- 2013-09-16 00:00, 2012-05-31 00:00, 2009-02-15 00:00, 2007-12-18 00:00, 2006-12-19 00:00, 2004-11-19 00:00, 2004-08-11 00:00, 2004-06-11 00:00, 2003-09-29 00:00, 2003-04-02 00:00, 2002-12-05 00:00, 2001-06-25 00:00
- Namespace
- cisco
- Source file
CISCO-CAT6K-CROSSBAR-MIB- Digest
sha256:56f6173fd9ec525e09790bad21f37cc870e367bd61c11b863c00aaad3560a8d7
Description
The Catalyst 6000 Crossbar MIB provides instrumentation for configuration and operation of the crossbar switching fabric module, and additional functionalities for switching bus and internal bus, etc.
Contact
Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cat6000@cisco.com
Imports
| From | Symbols |
|---|---|
| CISCO-QOS-PIB-MIB | Percent |
| CISCO-SMI | ciscoMgmt |
| ENTITY-MIB | entPhysicalDescr, entPhysicalIndex, entPhysicalName, entPhysicalVendorType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CISCO-CAT6K-CROSSBAR-MIB CISCO-QOS-PIB-MIB CISCO-SMI ENTITY-MIB IANA-ENTITY-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ChannelStatus TEXTUAL-CONVENTION Status of the Channel. | current | |||
| FabricChannelNumber TEXTUAL-CONVENTION Fabric channel number. | current | |||
| ModuleSlotNumber TEXTUAL-CONVENTION Slot number of the module. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ciscoCat6kXbarMIBNotifs OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.0 | |||
| ciscoCat6kXbarMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1 | |||
| cc6kxbarConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.1 | |||
| cc6kxbarFallbackMode OBJECT-TYPE cc6kxbarFallbackMode controls system fallback to bus-mode after loss of switching fabric module. 'true' - When the last fabric card is removed system will adjust the supervisor and line cards switching mode automatically without resetting the system. With this feature enabled, the switch might lose traffic while it's changing the switching mode. 'false' - All the ports in the system will be disabled when the last fabric card is removed. | 1.3.6.1.4.1.9.9.217.1.1.1 | TruthValue | read-write | current |
| cc6kxbarBusOnlyModeAllowed OBJECT-TYPE Indicates whether bus mode is administratively enabled on the device or not. | 1.3.6.1.4.1.9.9.217.1.1.2 | TruthValue | read-write | current |
| cc6kxbarTruncatedModeAllowed OBJECT-TYPE Indicates whether truncated mode is administratively enabled on the device or not. | 1.3.6.1.4.1.9.9.217.1.1.3 | TruthValue | read-write | current |
| cc6kxbarMinFabricPresent OBJECT-TYPE This object indicates the minimum number of switching fabric capable modules to be present in the system, for any switching fabric capable module to be in 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode, when cc6kxbarTruncatedModeOper is 'false'. | 1.3.6.1.4.1.9.9.217.1.1.4 | Unsigned32 | read-write | current |
| cc6kxbarLcdBannerTable OBJECT-TYPE cc6kxbarLcdBannerTable configures the Lcd banner of the fabric module. | 1.3.6.1.4.1.9.9.217.1.1.5 | not-accessible | current | |
| cc6kxbarLcdBannerEntry OBJECT-TYPE An entry in cc6kxbarLcdBannerTable. Entries are created by the agent based on the size of the lcd banner. | 1.3.6.1.4.1.9.9.217.1.1.5.1 | not-accessible | current | |
| cc6kxbarLcdBannerIndex OBJECT-TYPE Object which specifies a unique entry in the table. | 1.3.6.1.4.1.9.9.217.1.1.5.1.1 | Unsigned32 | not-accessible | current |
| cc6kxbarLcdBannerBanner OBJECT-TYPE Message that would be displayed on the fabric card LCD. The size of cc6kxbarLcdBannerBanner should be less than or equal to the cc6kxbarLcdBannerMaxSize value. | 1.3.6.1.4.1.9.9.217.1.1.5.1.2 | DisplayString | read-write | current |
| cc6kxbarLcdBannerMaxSize OBJECT-TYPE Maximum size of the associated cc6kxbarLcdBannerBanner object. | 1.3.6.1.4.1.9.9.217.1.1.5.1.3 | Unsigned32 | read-only | current |
| cc6kxbarTruncatedModeOper OBJECT-TYPE Indicates if the truncated mode is operationally enabled on the device or not. 'true' - With the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for all the fabric capable modules. 'false'- With the cc6kxbarMinFabricPresent fabric capable modules and the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for fabric capable modules. | 1.3.6.1.4.1.9.9.217.1.1.6 | TruthValue | read-only | current |
| cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode. | 1.3.6.1.4.1.9.9.217.1.1.7 | TruthValue | read-write | current |
| cc6kxbarForceBusMode OBJECT-TYPE Indicates whether some affected modules are forced to be in 'busmode' or not. 'true' - Setting cc6kxbarForceBusMode to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to 'busmode'. Changing the cc6kxbarForceBusMode to 'true' will make all the affected modules reloaded and booted up as non fabric capable modules. 'false'- Setting cc6kxbarForceBusMode to 'false' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to the default value. Changing cc6kxbarForceBusMode to 'false' will make all the affected modules reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode. | 1.3.6.1.4.1.9.9.217.1.1.8 | TruthValue | read-write | current |
| cc6kxbarBusOnlyModeOper OBJECT-TYPE Indicates if the bus mode is operationally enabled on the device or not. 'true' - Modules are allowed to run in 'busmode'. 'false' - None of the modules are allowed to run in 'busmode' i.e., All the non-fabric capable modules will be powered off. Absence of fabric module results in all the fabric capable modules being powered off. | 1.3.6.1.4.1.9.9.217.1.1.9 | TruthValue | read-only | current |
| cc6kxbarStatus OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.2 | |||
| cc6kxbarFabricActiveSlot OBJECT-TYPE cc6kxbarFabricActiveSlot indicates the slot number of the active switching fabric module. A value of zero indicates that the active switching fabric module is either powered down or not present in the chassis. | 1.3.6.1.4.1.9.9.217.1.2.1 | ModuleSlotNumber | read-only | current |
| cc6kxbarFabricBackupSlot OBJECT-TYPE cc6kxbarFabricBackupSlot indicates the slot number of the backup switching fabric module. A value of zero indicates that the backup switching fabric module is either powered down or not present in the chassis. | 1.3.6.1.4.1.9.9.217.1.2.2 | ModuleSlotNumber | read-only | current |
| cc6kxbarModuleModeTable OBJECT-TYPE cc6kxbarModuleModeTable indicates the switching mode of each module in the system. | 1.3.6.1.4.1.9.9.217.1.2.3 | not-accessible | current | |
| cc6kxbarModuleModeEntry OBJECT-TYPE An entry in cc6kxbarModuleModeTable. The agent creates an entry when a non switching fabric module is inserted in the chassis. The agent destroys an entry when a non switching fabric module is power down or reset or removed from the chassis. | 1.3.6.1.4.1.9.9.217.1.2.3.1 | not-accessible | current | |
| cc6kxbarModuleModeModule OBJECT-TYPE The module slot number. | 1.3.6.1.4.1.9.9.217.1.2.3.1.1 | ModuleSlotNumber | not-accessible | current |
| cc6kxbarModuleModeSwitchingMode OBJECT-TYPE cc6kxbarModuleModeSwitchingMode indicates switching mode of the cc6kxbarModuleModeModule. 'busmode' - Modules in this mode don't use fabric. Backplane is used for both lookup and data forwarding. 'crossbarmode' - Modules in this mode use backplane for forwarding decision and fabric for data forwarding 'dcefmode' - Modules in this mode use fabric for data forwarding and local forwarding is enabled. | 1.3.6.1.4.1.9.9.217.1.2.3.1.2 | INTEGER {busmode(1), crossbarmode(2), dcefmode(3)} | read-only | current |
| cc6kxbarModuleChannelTable OBJECT-TYPE cc6kxbarModuleChannelTable shows the operational status of fabric channels. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero. | 1.3.6.1.4.1.9.9.217.1.2.4 | not-accessible | current | |
| cc6kxbarModuleChannelEntry OBJECT-TYPE An entry in cc6kxbarModuleChannelTable. | 1.3.6.1.4.1.9.9.217.1.2.4.1 | not-accessible | current | |
| cc6kxbarModuleChannelModule OBJECT-TYPE The module slot number. | 1.3.6.1.4.1.9.9.217.1.2.4.1.1 | ModuleSlotNumber | not-accessible | current |
| cc6kxbarModuleChannelChannel OBJECT-TYPE Fabric channel number of the cc6kxbarModuleChannelModule. | 1.3.6.1.4.1.9.9.217.1.2.4.1.2 | FabricChannelNumber | not-accessible | current |
| cc6kxbarModuleChannelModStatus OBJECT-TYPE The status of the fabric channel at the cc6kxbarModuleChannelModule. | 1.3.6.1.4.1.9.9.217.1.2.4.1.3 | ChannelStatus | read-only | current |
| cc6kxbarModuleChannelFabStatus OBJECT-TYPE The status of the fabric channel at the cc6kxbarFabricActiveSlot. | 1.3.6.1.4.1.9.9.217.1.2.4.1.4 | ChannelStatus | read-only | current |
| cc6kxbarModuleChannelSpeed OBJECT-TYPE The speed in mega bits per second of the cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule. | 1.3.6.1.4.1.9.9.217.1.2.4.1.5 | Gauge32 | read-only | current |
| cc6kxbarStatistics OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.3 | |||
| cc6kxbarStatisticsTable OBJECT-TYPE cc6kxbarStatisticsTable gives the fabric channel counters and utilization information. This table will be instantiated when cc6kxbarFabricActiveSlot has a valid value other than zero. | 1.3.6.1.4.1.9.9.217.1.3.1 | not-accessible | current | |
| cc6kxbarStatisticsEntry OBJECT-TYPE An entry in cc6kxbarStatisticsTable. | 1.3.6.1.4.1.9.9.217.1.3.1.1 | not-accessible | current | |
| cc6kxbarStatisticsModule OBJECT-TYPE The module slot number. | 1.3.6.1.4.1.9.9.217.1.3.1.1.1 | ModuleSlotNumber | not-accessible | current |
| cc6kxbarStatisticsChannel OBJECT-TYPE Fabric channel number associated with the cc6kxbarStatisticsModule. | 1.3.6.1.4.1.9.9.217.1.3.1.1.2 | FabricChannelNumber | not-accessible | current |
| cc6kxbarStatisticsInErrors OBJECT-TYPE The total number of error packets received on cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized. | 1.3.6.1.4.1.9.9.217.1.3.1.1.3 | Counter32 | read-only | current |
| cc6kxbarStatisticsOutErrors OBJECT-TYPE The total number of error packets transmitted on cc6kxbarStatisticsModule through the cc6kxbarStatisticsChannel since this entry was last initialized. | 1.3.6.1.4.1.9.9.217.1.3.1.1.4 | Counter32 | read-only | current |
| cc6kxbarStatisticsOutDropped OBJECT-TYPE The total number of dropped packets transmitted on the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized. | 1.3.6.1.4.1.9.9.217.1.3.1.1.5 | Counter32 | read-only | current |
| cc6kxbarStatisticsInUtil OBJECT-TYPE Input utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. | 1.3.6.1.4.1.9.9.217.1.3.1.1.6 | Percent | read-only | current |
| cc6kxbarStatisticsOutUtil OBJECT-TYPE Output utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. | 1.3.6.1.4.1.9.9.217.1.3.1.1.7 | Percent | read-only | current |
| cc6kxbarStatisticsPeakInUtil OBJECT-TYPE Indicates the peak value of cc6kxbarStatisticsInUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. | 1.3.6.1.4.1.9.9.217.1.3.1.1.8 | Percent | read-only | current |
| cc6kxbarStatisticsPeakTmInUtil OBJECT-TYPE Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakInUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakInUtil is '0'. | 1.3.6.1.4.1.9.9.217.1.3.1.1.9 | DateAndTime | read-only | current |
| cc6kxbarStatisticsPeakOutUtil OBJECT-TYPE Indicates the peak value of cc6kxbarStatisticsOutUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. | 1.3.6.1.4.1.9.9.217.1.3.1.1.10 | Percent | read-only | current |
| cc6kxbarStatisticsPeakTmOutUtil OBJECT-TYPE Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakOutUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakOutUtil is '0'. | 1.3.6.1.4.1.9.9.217.1.3.1.1.11 | DateAndTime | read-only | current |
| cc6kxbarStatisticsLbusDrops OBJECT-TYPE This object indicates the number of packets that have been deterministically dropped due to the threshold on the local bus FIFO, errors and exception conditions. | 1.3.6.1.4.1.9.9.217.1.3.1.1.12 | Counter32 | read-only | current |
| cc6kxbarErrorTable OBJECT-TYPE cc6kxbarErrorTable provides the fabric channel error information. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero. | 1.3.6.1.4.1.9.9.217.1.3.2 | not-accessible | current | |
| cc6kxbarErrorEntry OBJECT-TYPE An entry in cc6kxbarErrorTable for a specific fabric channel on a specific module. | 1.3.6.1.4.1.9.9.217.1.3.2.1 | not-accessible | current | |
| cc6kxbarErrorModule OBJECT-TYPE The module slot number. | 1.3.6.1.4.1.9.9.217.1.3.2.1.1 | ModuleSlotNumber | not-accessible | current |
| cc6kxbarErrorChannel OBJECT-TYPE Fabric channel number associated with the cc6kxbarErrorModule. | 1.3.6.1.4.1.9.9.217.1.3.2.1.2 | FabricChannelNumber | not-accessible | current |
| cc6kxbarErrorModuleCrc OBJECT-TYPE Indicates the total number of CRC error packets for the cc6kxbarErrorChannel of the cc6kxbarErrorModule. | 1.3.6.1.4.1.9.9.217.1.3.2.1.3 | Gauge32 | read-only | current |
| cc6kxbarErrorModuleHbeat OBJECT-TYPE Indicates the total number of heartbeat misses detected for the cc6kxbarErrorChannel of the cc6kxbarErrorModule. | 1.3.6.1.4.1.9.9.217.1.3.2.1.4 | Gauge32 | read-only | current |
| cc6kxbarErrorModuleSync OBJECT-TYPE Indicates the total number of times cc6kxbarErrorModule could not sync to the active switching fabric module. | 1.3.6.1.4.1.9.9.217.1.3.2.1.5 | Gauge32 | read-only | current |
| cc6kxbarErrorModuleDDRSync OBJECT-TYPE Indicates the total number of DDR(Double Data Rate) channel sync errors for the cc6kxbarErrorChannel of the cc6kxbarErrorModule. | 1.3.6.1.4.1.9.9.217.1.3.2.1.6 | Gauge32 | read-only | current |
| cc6kxbarErrorChannelSync OBJECT-TYPE Indicates the total number of sync errors received at cc6kxbarErrorChannel. | 1.3.6.1.4.1.9.9.217.1.3.2.1.7 | Gauge32 | read-only | current |
| cc6kxbarErrorChannelBuffer OBJECT-TYPE Indicates the total number of times the memory buffer for cc6kxbarErrorChannel of the cc6kxbarErrorModule is full. | 1.3.6.1.4.1.9.9.217.1.3.2.1.8 | Gauge32 | read-only | current |
| cc6kxbarErrorChannelTimeout OBJECT-TYPE Indicates the total number of timeouts for input from the cc6kxbarErrorChannel of the cc6kxbarErrorModule. | 1.3.6.1.4.1.9.9.217.1.3.2.1.9 | Gauge32 | read-only | current |
| cc6kxbarSwBusObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.4 | |||
| cc6kxbarSwBusSwitchingStatus OBJECT-TYPE Indicates the current switching status of the switching bus on the system. normal -- the switching bus is under normal packet switching operation. stalled -- the switching bus has stopped packet switching but is still attached to the system, i.e., the switching bus is stalled. isolated -- the switching bus has stopped packet switching and is detached from the system, i.e., the switching bus is isolated. The object is only instantiated on systems which support switching bus switching detection feature. | 1.3.6.1.4.1.9.9.217.1.4.1 | INTEGER {normal(1), stalled(2), isolated(3)} | read-only | current |
| cc6kxbarSwBusFailureDuration OBJECT-TYPE Indicates the failure duration of the switching bus since the switching bus has transitioned out of the normal(1) state as monitored by cc6kxbarSwBusSwitchingStatus. If the object value of cc6kxbarSwBusSwitchingStatus is normal(1), then the object value of cc6kxbarSwBusFailureDuration should be zero. The object is only instantiated on systems which support switching bus switching detection feature. | 1.3.6.1.4.1.9.9.217.1.4.2 | Unsigned32 | read-only | current |
| cc6kxbarSwBusNotifEnable OBJECT-TYPE Indicates whether or not the notification cc6kxbarSwBusStatusChangeNotif should be generated when there is change in the switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus. The object is only instantiated on systems which support switching bus switching detection feature. | 1.3.6.1.4.1.9.9.217.1.4.3 | TruthValue | read-write | current |
| cc6kxbarSwBusUtilization OBJECT-TYPE Indicates the percentage of bandwidth utilization of the switching bus. | 1.3.6.1.4.1.9.9.217.1.4.4 | Percent | read-only | current |
| cc6kxbarSwBusPeakUtilization OBJECT-TYPE Indicates the peak percentage value of bandwidth utilization of the switching bus since the system started. | 1.3.6.1.4.1.9.9.217.1.4.5 | Percent | read-only | current |
| cc6kxbarSwBusPeakTimeUtil OBJECT-TYPE Indicates the time at which the peak percentage value of bandwidth utilization of the switching bus value occurred. | 1.3.6.1.4.1.9.9.217.1.4.6 | DateAndTime | read-only | current |
| cc6kxbarIntBusObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.5 | |||
| cc6kxbarIntBusNotifEnable OBJECT-TYPE Indicates whether the generation of a specified notification for internal bus is enabled or not. If a bit corresponding to a notification is set to 1, then that notification can be generated. intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif notification. intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif notification. | 1.3.6.1.4.1.9.9.217.1.5.1 | Bits {intBusCRCErrExcd(0), intBusCRCErrRcvrd(1)} | read-write | current |
| cc6kxbarIntBusCRCErrTable OBJECT-TYPE A table containing internal bus CRC error information on a list of physical entities (such as modules). | 1.3.6.1.4.1.9.9.217.1.5.2 | not-accessible | current | |
| cc6kxbarIntBusCRCErrEntry OBJECT-TYPE An entry containing internal bus CRC error information on a physical entity (such as a module). | 1.3.6.1.4.1.9.9.217.1.5.2.1 | not-accessible | current | |
| cc6kxbarIntBusCRCErrExcdStatus OBJECT-TYPE Indicates whether the internal bus CRC error on a physical entity is currently exceeding the fatal threshold or not. | 1.3.6.1.4.1.9.9.217.1.5.2.1.1 | TruthValue | read-only | current |
| cc6kxbarIntBusCRCErrExcdCount OBJECT-TYPE Indicates the number of times the internal bus CRC error on a physical entity has exceeded the fatal threshold. | 1.3.6.1.4.1.9.9.217.1.5.2.1.2 | Unsigned32 | read-only | current |
| cc6kxbarFlowCtrlObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.6 | |||
| cc6kxbarFlowCtrlNotifEnable OBJECT-TYPE Specifies whether the generation of a specified notification for flow control feature is enabled or not. If a bit corresponding to a notification is set to one, then that notification can be generated. busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif notification. | 1.3.6.1.4.1.9.9.217.1.6.1 | Bits {busThreshExcd(0)} | read-write | current |
| cc6kxbarFlowCtrlBusFIFOThrMode OBJECT-TYPE Specifies the mode configuration of the system bus flow control FIFO threshold. off -- the flow control FIFO threshold is set to the original value defined by the system. on -- the flow control FIFO threshold is set to the lower value defined by the system. auto -- the system starts monitoring the system bus flow control FIFO threshold and will change the flow control FIFO threshold from the original value to the lower value when the system detects the first occurrence of the threshold exceeding on a physical entity (such as a module) over the system allowed limit. | 1.3.6.1.4.1.9.9.217.1.6.2 | INTEGER {off(1), on(2), auto(3)} | read-write | current |
| cc6kxbarFlowCtrlBusFIFOThrValue OBJECT-TYPE Indicates the current value of the system bus flow control FIFO threshold, whether it is the original value or the lower value. | 1.3.6.1.4.1.9.9.217.1.6.3 | INTEGER {original(1), lower(2)} | read-only | current |
| cc6kxbarFlowCtrlBusFIFOTransTime OBJECT-TYPE Indicates the value of sysUpTime at the time that the system bus flow control FIFO threshold is transitioned to lower value when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This object will take on the value of zero when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'original'. | 1.3.6.1.4.1.9.9.217.1.6.4 | TimeStamp | read-only | current |
| cc6kxbarSystemCapacityObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.7 | |||
| cc6kxbarSysCapPfcOperMode OBJECT-TYPE Indicates the operating mode of the policy feature card (PFC). unknown -- unknown. pfc3a -- Policy feature card 3A. pfc3b -- Policy feature card 3B. pfc3bxl -- Policy feature card 3B XL. pfc3cst1 -- Policy feature card 3C ST1. pfc3cxlst1 -- Policy feature card 3C XL ST1. pfc3c -- Policy feature card 3C. pfc3cxl -- Policy feature card 3C XL. pfc4 -- Policy feature card 4. pfc4xl -- Policy feature card 4 XL. pfc4xxl -- Policy feature card 4 XXL. pfc4lite -- Policy feature card 4 Lite. | 1.3.6.1.4.1.9.9.217.1.7.1 | INTEGER {unknown(1), pfc3a(2), pfc3b(3), pfc3bxl(4), pfc3cst1(5), pfc3cxlst1(6), pfc3c(7), pfc3cxl(8), pfc4(9), pfc4xl(10), pfc4xxl(11), pfc4lite(12)} | read-only | current |
| cc6kxbarSysCapSwitchResTable OBJECT-TYPE A cc6kxbarSysCapSwitchResTable entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9). | 1.3.6.1.4.1.9.9.217.1.7.2 | not-accessible | current | |
| cc6kxbarSysCapSwitchResEntry OBJECT-TYPE A cc6kxbarSysCapSwitchResEntry entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9). Entries are created by the agent at the system power-up or module insertion. Entries are deleted by the agent upon module removal. | 1.3.6.1.4.1.9.9.217.1.7.2.1 | not-accessible | current | |
| cc6kxbarSysCapSwitchResSeries OBJECT-TYPE Indicates the module series for traffic forwarding options. unknown -- unknown. supervisor -- supervisor module. classic -- classic module. fabric -- fabric module. dcef720 -- dCEF720 module. cef720 -- CEF720 module. dcef256 -- dCEF256 module. cef256 -- CEF256 module. | 1.3.6.1.4.1.9.9.217.1.7.2.1.1 | INTEGER {unknown(1), supervisor(2), classic(3), fabric(4), dcef720(5), cef720(6), dcef256(7), cef256(8)} | read-only | current |
| cc6kxbarSysCapSwitchResCefMode OBJECT-TYPE Indicates the Cisco Express Forwarding (CEF) mode of the module. notApplicable -- not applicable for this module. dcef -- distributed CEF. cef -- CEF. | 1.3.6.1.4.1.9.9.217.1.7.2.1.2 | INTEGER {notApplicable(1), dcef(2), cef(3)} | read-only | current |
| cc6kxbarErrorRecoveryObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.8 | |||
| cc6kxbarErrRcvryThreshLink OBJECT-TYPE Specifies the threshold on fabric link errors occurring in a channel for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.1 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarErrRcvryThreshPersLink OBJECT-TYPE Specifies the threshold on persistent fabric link errors occurring in a channel for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.2 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarErrRcvrySwitchoverEnable OBJECT-TYPE Specifies whether the switchover to the standby fabric module is enabled or not on the detection of excessive fabric link errors occurring in a channel for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.3 | TruthValue | read-write | current |
| cc6kxbarErrRcvryPersLinkResync OBJECT-TYPE Specifies whether the system will resync the channel or not on the detection of excessive persistent fabric link errors in a channel for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.4 | TruthValue | read-write | current |
| cc6kxbarErrRcvryChResyncCount OBJECT-TYPE Specifies the consecutive number of times of channel resync within the time interval as specified by cc6kxbarErrRcvryChResyncInterval, over which the channel resync is considered as failure for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.5 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarErrRcvryChResyncInterval OBJECT-TYPE Specifies the time interval for the consecutive counting of channel resync for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.1.8.6 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarTrafficMonitorObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.9 | |||
| cc6kxbarTrafficMonitorSwBusObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.9.1 | |||
| cc6kxbarTMSwBusUtilEnable OBJECT-TYPE Specifies whether the traffic monitor feature is enabled on the switching bus or not. | 1.3.6.1.4.1.9.9.217.1.9.1.1 | TruthValue | read-write | current |
| cc6kxbarTMSwBusUtilInterval OBJECT-TYPE Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold. | 1.3.6.1.4.1.9.9.217.1.9.1.2 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarTMSwBusUtilThreshold OBJECT-TYPE Specifies the threshold of the switching bus traffic utilization. | 1.3.6.1.4.1.9.9.217.1.9.1.3 | Percent | read-write | current |
| cc6kxbarTMSwBusUtilLogCount OBJECT-TYPE Indicates the number of times the following events are logged for the switching bus: 1. the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). 2. the switching bus traffic utilization has fallen below the configured threshold. | 1.3.6.1.4.1.9.9.217.1.9.1.4 | Counter32 | read-only | current |
| cc6kxbarTMSwBusUtilLastLogTime OBJECT-TYPE Indicates the last logging time of the events as counted in cc6kxbarTMSwBusUtilLogCount. This object will contain 0-1-1,00:00:00.0 when the value of cc6kxbarTMSwBusUtilLogCount is zero. | 1.3.6.1.4.1.9.9.217.1.9.1.5 | DateAndTime | read-only | current |
| cc6kxbarTMSwBusUtilLogInterval OBJECT-TYPE Specifies the logging interval if the switching bus traffic utilization keeps staying above the cc6kxbarTMSwBusUtilThreshold. | 1.3.6.1.4.1.9.9.217.1.9.1.6 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarTMSwBusUtilUtilization OBJECT-TYPE The switching bus traffic utilization included in the notification currently being sent. | 1.3.6.1.4.1.9.9.217.1.9.1.7 | Percent | accessible-for-notify | current |
| cc6kxbarTMSwBusUtilNotifEnable OBJECT-TYPE Specifies whether the generation of c6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is disabled. | 1.3.6.1.4.1.9.9.217.1.9.1.8 | TruthValue | read-write | current |
| cc6kxbarTrafficMonitorChObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.1.9.2 | |||
| cc6kxbarTMChUtilTable OBJECT-TYPE cc6kxbarTrafficMntrChUtilTable provides the information on the traffic utilization of each fabric channel associated with each module slot for a given traffic direction in the chassis. | 1.3.6.1.4.1.9.9.217.1.9.2.1 | not-accessible | current | |
| cc6kxbarTMChUtilEntry OBJECT-TYPE An entry in cc6kxbarTMChUtilTable. Each traffic direction for each fabric channel associated with each module slot in the chassis will have an entry in this table. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1 | not-accessible | current | |
| cc6kxbarTMChUtilModule OBJECT-TYPE Indicates the module slot number in the chassis. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.1 | ModuleSlotNumber | not-accessible | current |
| cc6kxbarTMChUtilChannel OBJECT-TYPE Indicates the fabric channel number associated with the corresponding cc6kxbarTMChUtilModule. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.2 | FabricChannelNumber | not-accessible | current |
| cc6kxbarTMChUtilDirection OBJECT-TYPE Indicates the direction of traffic to be monitored. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.3 | INTEGER {ingress(1), egress(2)} | not-accessible | current |
| cc6kxbarTMChUtilEnable OBJECT-TYPE Specifies whether the traffic monitor feature is enabled on a fabric channel for a given traffic direction or not. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.4 | TruthValue | read-write | current |
| cc6kxbarTMChUtilInterval OBJECT-TYPE Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.5 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarTMChUtilThreshold OBJECT-TYPE Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.6 | Percent | read-write | current |
| cc6kxbarTMChUtilLogCount OBJECT-TYPE Indicates the number of times the following events are logged on a fabric channel for a given direction. 1. the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). 2. the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.7 | Counter32 | read-only | current |
| cc6kxbarTMChUtilLastLogTime OBJECT-TYPE Indicates the last logging time of the events as counted in the corresponding cc6kxbarTMChUtilLogCount on a fabric channel for a given traffic direction. This object will contain 0-1-1,00:00:00.0 when the corresponding cc6kxbarTMChUtilLogCount is zero. | 1.3.6.1.4.1.9.9.217.1.9.2.1.1.8 | DateAndTime | read-only | current |
| cc6kxbarTMChUtilLogInterval OBJECT-TYPE Specifies the logging interval if the traffic utilization for a fabric channel on a given traffic direction keeps staying above its corresponding cc6kxbarTMChUtilThreshold. | 1.3.6.1.4.1.9.9.217.1.9.2.2 | Unsigned32 (1..4294967295) | read-write | current |
| cc6kxbarTMChUtilUtilization OBJECT-TYPE The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent. | 1.3.6.1.4.1.9.9.217.1.9.2.3 | Percent | accessible-for-notify | current |
| cc6kxbarTMChUtilNotifEnable OBJECT-TYPE Specifies whether the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is disabled. | 1.3.6.1.4.1.9.9.217.1.9.2.4 | TruthValue | read-write | current |
| cc6kxbarMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.3 | |||
| cc6kxbarMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.3.1 | |||
| cc6kxbarMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.217.3.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| cc6kxbarSwBusStatusChangeNotif NOTIFICATION-TYPE A cc6kxbarSwBusStatusChangeNotif notification is sent by the device when there is change in switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus. | 1.3.6.1.4.1.9.9.217.0.1 | current |
| cc6kxbarIntBusCRCErrExcdNotif NOTIFICATION-TYPE A cc6kxbarIntBusCRCThreshExcdNotif notification is sent by the system when the system has detected that the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has exceeded the fatal threshold. | 1.3.6.1.4.1.9.9.217.0.2 | current |
| cc6kxbarIntBusCRCErrRcvrdNotif NOTIFICATION-TYPE A cc6kxbarIntBusCRCErrRcvrdNotif notification is sent by the system when the system has recovered as the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has fallen below the normal threshold. | 1.3.6.1.4.1.9.9.217.0.3 | current |
| cc6kxbarFlowCtrlBusThrExcdNotif NOTIFICATION-TYPE A cc6kxbarFlowCtrlBusThrExcdNotif notification is sent by the system when the system detects the first occurrence of the system bus flow control FIFO threshold exceeding on a physical entity (such as a module) over the system allowed limit when the object value of cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'. | 1.3.6.1.4.1.9.9.217.0.4 | current |
| cc6kxbarTMSwBusUtilAboveNotif NOTIFICATION-TYPE This notification is sent when the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilAboveNotif is sent. | 1.3.6.1.4.1.9.9.217.0.5 | current |
| cc6kxbarTMSwBusUtilBelowNotif NOTIFICATION-TYPE This notification is sent when the switching bus traffic utilization has fallen below the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilBelowNotif is sent. | 1.3.6.1.4.1.9.9.217.0.6 | current |
| cc6kxbarTMChUtilAboveNotif NOTIFICATION-TYPE This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilAboveNotif is sent. | 1.3.6.1.4.1.9.9.217.0.7 | current |
| cc6kxbarTMChUtilBelowNotif NOTIFICATION-TYPE This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilBelowNotif is sent. | 1.3.6.1.4.1.9.9.217.0.8 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| cc6kxbarMIBCompliance MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.2 | deprecated |
| cc6kxbarMIBComplianceVer1 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.3 | deprecated |
| cc6kxbarMIBComplianceVer2 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.4 | deprecated |
| cc6kxbarMIBComplianceVer3 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.5 | deprecated |
| cc6kxbarMIBComplianceVer4 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.6 | deprecated |
| cc6kxbarMIBComplianceVer5 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.7 | deprecated |
| cc6kxbarMIBComplianceVer6 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.8 | deprecated |
| cc6kxbarMIBComplianceVer7 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.9 | deprecated |
| cc6kxbarMIBComplianceVer8 MODULE-COMPLIANCE The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB. | 1.3.6.1.4.1.9.9.217.3.1.10 | current |
| cc6kxbarModuleStatusGroup OBJECT-GROUP A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module. cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1. | 1.3.6.1.4.1.9.9.217.3.2.1 | deprecated |
| cc6kxbarChannelStatusGroup OBJECT-GROUP A collection of objects providing status and configuration of the fabric channel. | 1.3.6.1.4.1.9.9.217.3.2.2 | current |
| cc6kxbarChannelStatisticsGroup OBJECT-GROUP A collection of objects providing statistics for the fabric channel. cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1. | 1.3.6.1.4.1.9.9.217.3.2.3 | deprecated |
| cc6kxbarFallbackGroup OBJECT-GROUP This object controls system fallback to bus-mode after loss of switching fabric module. | 1.3.6.1.4.1.9.9.217.3.2.4 | current |
| cc6kxbarBusOnlyAllowedGroup OBJECT-GROUP This object determines the value of cc6kxbarModuleModeSwitchingMode of each module. | 1.3.6.1.4.1.9.9.217.3.2.5 | current |
| cc6kxbarModuleStatusGroupVer1 OBJECT-GROUP A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module. | 1.3.6.1.4.1.9.9.217.3.2.6 | current |
| cc6kxbarChannelStatisticsGroupVer1 OBJECT-GROUP A collection of objects providing statistics for the fabric channel. | 1.3.6.1.4.1.9.9.217.3.2.7 | current |
| cc6kxbarLcdBannerGroup OBJECT-GROUP A collection of objects providing configuration of the lcd Banner of the fabric module. | 1.3.6.1.4.1.9.9.217.3.2.8 | current |
| cc6kxbarChannelUtilGroup OBJECT-GROUP These object determines Input and Output Utilization of the fabric channel. | 1.3.6.1.4.1.9.9.217.3.2.9 | current |
| cc6kxbarChannelSpeedGroup OBJECT-GROUP A collection of objects providing the speed of the fabric channel. | 1.3.6.1.4.1.9.9.217.3.2.10 | current |
| cc6kxbarSwBusGroup OBJECT-GROUP A collection of objects for the switching bus switching detection feature. | 1.3.6.1.4.1.9.9.217.3.2.11 | current |
| cc6kxbarSwBusNotifGroup NOTIFICATION-GROUP A collection of notifications for the switching bus switching detection feature. | 1.3.6.1.4.1.9.9.217.3.2.12 | current |
| cc6kxbarTruncatedOperGroup OBJECT-GROUP A collection of objects providing the operational truncated mode. | 1.3.6.1.4.1.9.9.217.3.2.13 | current |
| cc6kxbarIntBusNotifControlGroup OBJECT-GROUP A collection of objects to control the notification generation for internal bus. | 1.3.6.1.4.1.9.9.217.3.2.14 | current |
| cc6kxbarIntBusCRCErrNotifGroup NOTIFICATION-GROUP A collection of notifications for the internal bus CRC error. | 1.3.6.1.4.1.9.9.217.3.2.15 | current |
| cc6kxbarIntBusCRCErrGroup OBJECT-GROUP A collection of objects to indicate the internal bus CRC error information on a physical entity. | 1.3.6.1.4.1.9.9.217.3.2.16 | current |
| cc6kxbarDcefOnlyModeAllowedGroup OBJECT-GROUP A collection of objects providing the configuration and information about the dcef only mode feature. | 1.3.6.1.4.1.9.9.217.3.2.17 | current |
| cc6kxbarForceBusModeGroup OBJECT-GROUP A collection of objects providing the configuration and information about the force bus mode feature. | 1.3.6.1.4.1.9.9.217.3.2.18 | current |
| cc6kxbarFlowCtrlNotifCtrlGroup OBJECT-GROUP A collection of objects to control the notification generation for the system flow control feature. | 1.3.6.1.4.1.9.9.217.3.2.19 | current |
| cc6kxbarFlowCtrlBusThreshGroup OBJECT-GROUP A collection of objects providing configuration information about the system bus flow control FIFO threshold. | 1.3.6.1.4.1.9.9.217.3.2.20 | current |
| cc6kxbarFlowCtrlBusThrNotifGroup NOTIFICATION-GROUP A collection of notifications for the system bus flow control FIFO threshold exceeding. | 1.3.6.1.4.1.9.9.217.3.2.21 | current |
| cc6kxbarBusOnlyModeOperGroup OBJECT-GROUP A collection of objects providing the operational bus mode. | 1.3.6.1.4.1.9.9.217.3.2.22 | current |
| cc6kxbarSysCapPfcOperModeGroup OBJECT-GROUP A collection of objects providing the system information of PFC operational mode. | 1.3.6.1.4.1.9.9.217.3.2.23 | current |
| cc6kxbarSysCapSwitchResGroup OBJECT-GROUP A collection of objects providing the capacity information of switching resources in the system. | 1.3.6.1.4.1.9.9.217.3.2.24 | current |
| cc6kxbarChannelUtilGroup1 OBJECT-GROUP A collection of objects providing the information about peak input and output utilization of a specific fabric channel on a specific module. | 1.3.6.1.4.1.9.9.217.3.2.25 | current |
| cc6kxbarSwBusGroup1 OBJECT-GROUP A collection of objects providing the information about switching bus utilization. | 1.3.6.1.4.1.9.9.217.3.2.26 | current |
| cc6kxbarErrorGroup OBJECT-GROUP A collection of objects providing error statistics for a specific fabric channel on a specific module. | 1.3.6.1.4.1.9.9.217.3.2.27 | current |
| cc6kxbarErrRcvryThresholdGroup OBJECT-GROUP A collection of objects providing the configuration of thresholds on fabric link errors for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.3.2.28 | current |
| cc6kxbarErrRcvrySwitchoverGroup OBJECT-GROUP A collection of objects providing the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.3.2.29 | current |
| cc6kxbarErrRcvryPersLinkResGroup OBJECT-GROUP A collection of objects providing the configuration of channel resync on excessive persistent fabric link errors for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.3.2.30 | current |
| cc6kxbarErrRcvryChResyncGroup OBJECT-GROUP A collection of objects providing the configuration for channel resync threshold for the fabric error recovery feature. | 1.3.6.1.4.1.9.9.217.3.2.31 | current |
| cc6kxbarTMSwBusUtilGroup OBJECT-GROUP A collection of objects providing configuration information for traffic monitor feature on the switching bus. | 1.3.6.1.4.1.9.9.217.3.2.32 | current |
| cc6kxbarTMSwBusUtilNotifControlGroup OBJECT-GROUP A collection of objects to control the traffic monitor notification generation on the switching bus. | 1.3.6.1.4.1.9.9.217.3.2.33 | current |
| cc6kxbarTMSwBusUtilNotifObjectGroup OBJECT-GROUP A collection of objects included in the traffic monitor notifications on the switching bus. | 1.3.6.1.4.1.9.9.217.3.2.34 | current |
| cc6kxbarTMSwBusUtilNotifGroup NOTIFICATION-GROUP A collection of traffic monitor notifications on the switching bus. | 1.3.6.1.4.1.9.9.217.3.2.35 | current |
| cc6kxbarTMChUtilGroup OBJECT-GROUP A collection of objects providing the configuration information for traffic monitor feature on fabric channels. | 1.3.6.1.4.1.9.9.217.3.2.36 | current |
| cc6kxbarTMChUtilNotifControlGroup OBJECT-GROUP A collection of objects to control the traffic monitor notification generation on fabric channels. | 1.3.6.1.4.1.9.9.217.3.2.37 | current |
| cc6kxbarTMChUtilNotifObjectGroup OBJECT-GROUP A collection of objects included in the traffic monitor notifications on fabric channels. | 1.3.6.1.4.1.9.9.217.3.2.38 | current |
| cc6kxbarTMChUtilNotifGroup NOTIFICATION-GROUP A collection of traffic monitor notifications on fabric channels. | 1.3.6.1.4.1.9.9.217.3.2.39 | current |
| cc6kxbarStatisticsLbusDropGroup OBJECT-GROUP A collection of objects providing information for local bus drop packets statistics. | 1.3.6.1.4.1.9.9.217.3.2.40 | current |