BTI-7000-MIB
- Registered at
- 1.3.6.1.4.1.18070.1.31.3.6.1.4.1.18070.2.2.11.3.6.1.4.1.18070.2.2.2
- Last updated
- 2012-10-09 12:00
- Organization
- BTI Systems Inc.
- Revisions
- 2012-10-09 12:00, 2012-08-29 12:00, 2012-02-10 12:00, 2011-09-26 12:00, 2011-04-26 12:00, 2011-03-28 12:00, 2011-02-25 12:00, 2010-09-17 12:00, 2010-08-06 12:00, 2010-06-18 12:00, 2010-02-12 12:00, 2009-01-19 12:00, 2008-12-19 12:00, 2008-10-10 12:00, 2008-05-30 12:00, 2007-09-14 12:00, 2007-07-16 12:00, 2007-03-09 12:00, 2006-08-25 12:00, 2005-12-05 12:00, 2005-07-25 12:00, 2005-01-07 12:00, 2004-09-23 12:00, 2004-09-09 14:34, 2004-04-14 22:35, 2003-12-01 12:00
- Namespace
- bti
- Source file
BTI-7000-MIB- Digest
sha256:e611bc5ec42e8c59af636e1be866577c4f3b76cd36a56741ae9a4f651750fce5
Description
The external MIB definitions for the BTI 7000 series products.
Contact
Technical Support BTI Systems Inc. 200-1000 Innovation Drive Kanata, Ontario, Canada, K2K 3E7 (613) 287-1700 support@btisystems.com
Imports
| From | Symbols |
|---|---|
| BTI-MIB | bti7000, btiModules |
| BTI-TC-MIB | AdminStatus, AmdPortType, AmdType, AreaID, BERType, CondReportType, CondServiceAffecting, CondSeverity, CpType, DesignatedRouterPriority, DuplexModeType, EnvNotifCodeType, FiberType, FixedX10, FixedX100, HoursAndMinutes, InetAddress, InetAddressType, InitializeCmd, LldpChassisId, LldpChassisIdSubtype, LldpPortId, LldpPortIdSubtype, LoopbackType, MediaRateType, MirrorConfigType, NotifCodeType, NotifObjectType, OaType, OcnType, OdunType, OperStatQlfr, OperStatus, PMIntervalType, PMMontype, PMValidity, PassivePortType, PowerFeedModeType, ProtSwEvtType, ProtSwOpCmd, ProtectionStatusType, PvxL1PortType, PvxPortType, ShelfConfigType, ShelfType, SlotType, StmnType, StsnType, SwitchIdxType, SyncSwEvtType, TimeZone, Unsigned64, UpgradeCompleteStage, VcnType, WDMGrid, XCType, XcvrProtocolType, XcvrType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
2 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BTI-7000-MIB BTI-MIB BTI-TC-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18070.2.2.1.14 | pvxObjects | |
| 1.3.6.1.4.1.18070.2.2.1.16 | opticalLayer | |
| 1.3.6.1.4.1.18070.2.2.2.1 | eventNotifications | |
| 1.3.6.1.4.1.18070.2.2.2.2 | conditionNotifications |
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| DataCommsPingCmd TEXTUAL-CONVENTION The DataCommsPingCmd textual convention is the value of the dataCommsPingCmd object which is used to perform a ping operation over the NE's OSC. The operation is initiated when a set request is performed on the dataCommsPingCmd object with a value corresponding to the ping action, as explained below. The valid values for DataCommsPingCmd that can be used in a set operation are: - 'ping', used to trigger the ping operation over the OSC A value of 'pingInProgress' is returned when the dataCommsPingCmd object is read in a get operation if the ping command entered has not yet completed, otherwise 'noOp' is returned. In order for the set request on a DataCommsPingCmd object to complete successfully, the dataCommsPingCmd object, along with the dataCommdPingAddress and optionally the dataCommsPingNumAttemps objects must be set in the same set request for a given row of the table. The purpose of these objects is: - dataCommsPingAddress: indicates the IP Address which is the target of the ping operation - dataCommsPingNumAttempts: indicates how many ping attempts are to be made in the ping operation Once the dataCommsPingCmd operation is completed by way of the set operation on the dataCommsPingCmd and associated objects, the result of the operation is checked by performing a get operation on the dataCommsPingNumSuccesses object. When the ping operation completes, the value of this object will be set to the number of the attempted ping trials that resulted in a successful ping. | current | |||
| DbBackupAndRestoreCmd TEXTUAL-CONVENTION The MSCP maintains all provisionable data in non-volatile storage so that configuration settings are retained during system shutdowns and restarts. The configuration database is version controlled to facilitate the detection of an incompatible software load and/or database. The BTI 7000 Series supports user-initiated backup and restore operations of the configuration database through the SNMP Set requests performed on the dbBackupAndRestoreCmd object with a value corresponding to the required action. In a backup operation, the database is uploaded to a user-specified network location (that is, a local PC or a remote PC) using the file transfer protocol (FTP), or it is stored locally on the MSCP. In a restore operation, the database is restored using a version of the file from an FTP server or locally from the MSCP. The integrity of the file is validated to ensure that it matches the current software load on the BTI 7000 Series. The DbBackupAndRestoreCmd textual convention is the value of the dbBackupAndRestoreCmd object, which is used to activate a database backup operation, or the various steps of a database restore operation. These operations are initiated when a set request is performed on the dbBackupAndRestoreCmd object with a value corresponding to the desired action, as explained below. A get request on this type returns the value noOp. The valid values for DbBackupAndRestoreCmd that can be used in a set operation are: - 'invokeBackup': used to perform a database backup operation. The operation may be used to perform a local database backup, or to save the database backup to a remote repository. - 'loadRestore': used to initiate a database restore operation. The operation may be the restoration of a local database backup or of a remote database backup - 'invokeRestore': continues a database restore operation after the loadRestore stage has completed. The database being restored is made active on the SCP circuit pack at this stage. - 'applyRestore': Obsolete this functionality is now done as part of the invokeRestore. - 'commitRestore': is used to complete a database restore operation and can be used after the applyRestore action completes - 'cancelRestore': is used to cancel and back out of a database restore operation in progress and can be used before the commitRestore action is called. In order for the set request on the dbBackupAndRestoreCmd object to complete successfully, the values of other objects must be set in the same set request for some of the commands. The additional objects required to be set along with the dbBackupAndRestoreCmd object for each DbBackupAndRestoreCmd value are listed below. - invokeBackup: must also set dbBackupAndRestoreType. If this object is set to remote, then the dbBackupAndRestoreAddress, dbBackupAndRestoreFtpUser and dbBackupAndRestorePswd object values must also be specified in the set request. The dbBackupAndRestoreCheckAlm object may optionally be set when the invokeBackup action is performed. Also when the dbBackupAndRestoreType is set to remote the dbBackupAndRestorePath is optional. If not specified the default name is used. - loadRestore: must also set dbBackupAndRestoreType. If this object is set to remote, then the dbBackupAndRestoreAddress, dbBackupAndRestorePath, dbBackupAndRestoreFtpUser and dbBackupAndRestorePswd object values must also be specified in the set request. The dbBackupAndRestoreCheckSysName object may be set when the loadRestore action is performed, but is not mandatory. - invokeRestore: must also set dbBackupAndRestoreInvokeFilename to confirm the name of the backed file to be used in the restore operation. Optionally, the dbBackupAndRestoreCheckAlm object may be set. - applyRestore, commitRestore, cancelRestore: no additional object values are required to be included for these set requests | current | |||
| DbBackupAndRestoreType TEXTUAL-CONVENTION Indicates the type of database backup operation to be performed, or the type of database restore operation to be performed. The meaning of the values are as follows. - 'local': for a database backup, the backup is made on the NE itself; for a database restore, the restoration is from a local database backup file - 'remote': for a database backup, the backup is made to an external ftp server; for a database restore, the restoration is from a database file located on an external ftp server - 'remoteSftp': for a database backup, the backup is made to an external sftp server; for a database restore, the restoration is from a database file located on an external sftp server | current | |||
| SwUpgradeCmd TEXTUAL-CONVENTION All BTI 7000 Series circuit packs are shipped with pre-loaded software. At system commissioning, it is not necessary to start the system by loading software. However, during the life cycle of the BTI 7000 Series, it might be necessary to upgrade the system software. Normally, the system software is upgraded to: � Support the functionality of new circuit packs � Provide new features for existing circuit packs � Add specific software improvements Performing a system software upgrade on the BTI 7000 Series is non-service affecting. The upgrade process is designed for application environments that require that the optical signals passing through the BTI 7000 Series are not interrupted. The BTI 7000 Series supports a user-initiated software upgrade operation through the SNMP Set requests performed on the swUpgradeCmd object with a value corresponding to the required action. The SwUpgradeCmd textual convention is the value of the swUpgradeCmd object, which is used to activate the various steps of the software upgrade procedure on the system. These steps are initiated when a set request is performed on the swUpgradeCmd object with a value corresponding to the desired action, as explained below. A get request will return the value noOp. The valid values for SwUpgradeCmd that can be used in a set operation are: - 'checkUpgrade': used to perform a pre-upgrade check of the system to ensure that it is ready for the upgrade process, and that the load files on the server are accessible. - 'loadUpgrade': used to initiate a system upgrade by downloading the load files from a remote server to the SCP software load storage area. - 'invokeUpgrade': continues a system upgrade operation after the loadUpgrade stage has completed. First the upgrade load is installed on all circuit packs in the system, then each card is rebooted to run the upgrade load. - 'commitUpgrade': is used to complete a system upgrade operation and can be used after the invkUpgrade action completes - 'cancelUpgrade': is used to cancel and back out of a system software upgrade operation in progress and can be used before the cmmtUpgrade action is called. - 'invokeScpUpgrade': is a special-purpose upgrade step used in place of the invkUpgrade value when an upgrade is being performed on an SCP pack only. Such a targeted upgrade is valid only when an SCP pack is replaced and the new pack requires a software upgrade to make its software version consistent with the system In order for the set request on the swUpgradeCmd object to complete successfully, the values of other objects must be set in the same set request for some of the commands. The additional objects required to be set along with the swUpgradeCmd object for each SwUpgradeCmd value are listed below. - checkUpgrade, loadUpgrade: must also set swUpgradeAddress, swUpgradePath, swUpgradeFtpUser, swUpgradeFtpPswd and swUpgradeFileTransferType object values to indicate where the ftp or sftp server with the upgrade load files is to be found, along with access parameters. - invokeUpgrade, invokeScpUpgrade: must also set the swUpgradeInvokeRelNum object to confirm the software version that is to be used in the upgrade. The swUpgradeCheckAlm object may be set, but is not mandatory. - commitUpgrade, cancelUpgrade: no additional object values are required to be specified for these set requests. | current | |||
| SwUpgradeFileTransferType TEXTUAL-CONVENTION Indicates the protocol of the file transfer. - 'ftp': an external ftp server is the source for the load to be transfered. - 'sftp': an external sftp server is the source for the load to be transfered. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| objects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1 | |||
| networkElement OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.1 | |||
| neSWVersion OBJECT-TYPE The software version that is active on the NE currently. | 1.3.6.1.4.1.18070.2.2.1.1.1 | DisplayString (SIZE(0..32)) | read-only | current |
| neNum OBJECT-TYPE This is a unique network element number used to identify the network element and to differentiate it from other NEs in the management domain. | 1.3.6.1.4.1.18070.2.2.1.1.2 | INTEGER (0..65535) | read-write | current |
| neSiteNum OBJECT-TYPE This is a network element site number used to uniquely identify the site of the NE and to differentiate it from other NE sites in the management domain. | 1.3.6.1.4.1.18070.2.2.1.1.3 | INTEGER (0..65535) | read-write | current |
| neDateAndTime OBJECT-TYPE The current system date and time, without time zone information. | 1.3.6.1.4.1.18070.2.2.1.1.4 | DateAndTime | read-write | current |
| neTimeZone OBJECT-TYPE The time zone in which the local time of this system is to be reported. Typically, the time zone is the one in which the system is physically located. | 1.3.6.1.4.1.18070.2.2.1.1.5 | TimeZone | read-write | current |
| neAutoDST OBJECT-TYPE A setting that indicates whether the system time should be updated automatically in accordance with the daylight savings time characteristics of the current time zone. | 1.3.6.1.4.1.18070.2.2.1.1.6 | INTEGER {on(1), off(2)} | read-write | current |
| neGateway OBJECT-TYPE The default IP routing gateway for network management interfaces on the node. If not specified, this object returns a value of 0.0.0.0. | 1.3.6.1.4.1.18070.2.2.1.1.7 | IpAddress | read-write | current |
| neSecGateway OBJECT-TYPE The secondary IP routing gateway for network management interfaces on the node. If not specified, this object returns a value of 0.0.0.0. | 1.3.6.1.4.1.18070.2.2.1.1.8 | IpAddress | read-write | current |
| neActiveGateway OBJECT-TYPE The IP routing gateway that is currently active on the node. If no gateway is active, this object returns a value of 0.0.0.0. | 1.3.6.1.4.1.18070.2.2.1.1.9 | IpAddress | read-only | current |
| neAutoProv OBJECT-TYPE A setting that specifies if automatic provisioning of equipment and facilities is enabled. If automatic provisioning is enabled, this object indicates the default administration status. The possible values include: - enabled: Applicable entities are auto provisioned with the initial state enabled. - disabled: Applicable entities are auto provisioned with the initial state disabled. - autoEnabled: Applicable entities are auto provisioned and placed into the auto-enabled state. - autoProvOff: Auto provisioning is disabled. | 1.3.6.1.4.1.18070.2.2.1.1.10 | INTEGER {enabled(1), disabled(2), autoEnabled(3), autoProvOff(4)} | read-write | current |
| neAutoDeProv OBJECT-TYPE The time delay after a physical shelf or circuit pack is removed from the NE before the provisioned entities that are supported by the removed equipment are automatically deprovisioned. If this object is set to a value of 000-00, auto deprovisioning is disabled. | 1.3.6.1.4.1.18070.2.2.1.1.11 | HoursAndMinutes | read-write | obsolete |
| neAutoEnabledTimer OBJECT-TYPE The system wide default auto-enable timer value. This timer specifies a time delay after a provisioned facility in the auto-enabled state is cleared of all alarms before the state of the facility transitions to enabled. The default value can be overridden by a facility-specific value that is specified when the facility is either provisioned or edited in its respective table. | 1.3.6.1.4.1.18070.2.2.1.1.12 | HoursAndMinutes | read-write | current |
| ntpClient OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.1.13 | |||
| ntpClientPollingRate OBJECT-TYPE The polling rate for the NTP client to periodically fetch the system time from the list of NTP servers configured. | 1.3.6.1.4.1.18070.2.2.1.1.13.1 | HoursAndMinutes | read-write | current |
| ntpClientAuthKey OBJECT-TYPE The NTP authentication key ID, if authentication is required. | 1.3.6.1.4.1.18070.2.2.1.1.13.2 | INTEGER (0..65535) | read-write | obsolete |
| ntpClientSyncState OBJECT-TYPE Status indicating if the node is in sync with one of the time servers. Either Y or N. | 1.3.6.1.4.1.18070.2.2.1.1.13.3 | DisplayString (SIZE(0..32)) | read-only | current |
| ntpClientStratum OBJECT-TYPE Specifies the stratum of the timer server the node in in sync with. | 1.3.6.1.4.1.18070.2.2.1.1.13.4 | INTEGER (0..65535) | read-only | current |
| ntpClientRefIPAddr OBJECT-TYPE The IP address of the time server the node is in sync with. | 1.3.6.1.4.1.18070.2.2.1.1.13.5 | DisplayString (SIZE(0..16)) | read-only | current |
| ntpClientAssocTable OBJECT-TYPE A list of NTP servers to poll for the system time. The NTP client then decides which is best clock source. | 1.3.6.1.4.1.18070.2.2.1.1.13.6 | not-accessible | current | |
| ntpClientAssocEntry OBJECT-TYPE The list entry for an NTP server. | 1.3.6.1.4.1.18070.2.2.1.1.13.6.1 | not-accessible | current | |
| ntpClientAssocIdx OBJECT-TYPE The IP address of the NTP server. | 1.3.6.1.4.1.18070.2.2.1.1.13.6.1.1 | IpAddress | not-accessible | current |
| ntpClientAssocRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the NTP client association table. | 1.3.6.1.4.1.18070.2.2.1.1.13.6.1.100 | RowStatus | read-create | current |
| ntpOldTimeAndDate OBJECT-TYPE The date and time of the system before the NTP client updated the system clock. | 1.3.6.1.4.1.18070.2.2.1.1.13.7 | DateAndTime | accessible-for-notify | current |
| ntpNewTimeAndDate OBJECT-TYPE The new system date and time updated by the NTP client. | 1.3.6.1.4.1.18070.2.2.1.1.13.8 | DateAndTime | accessible-for-notify | current |
| ntpRefIP OBJECT-TYPE This the NTP server being used as the clock reference for the system. | 1.3.6.1.4.1.18070.2.2.1.1.13.9 | IpAddress | accessible-for-notify | current |
| ntpRefStratum OBJECT-TYPE This is the stratum of the NTP server being used as the clock reference for the system. | 1.3.6.1.4.1.18070.2.2.1.1.13.10 | Unsigned32 | accessible-for-notify | current |
| neFPDetect OBJECT-TYPE A setting that indicates whether the system should report pack missing alarms. | 1.3.6.1.4.1.18070.2.2.1.1.14 | INTEGER {on(1), off(2)} | read-write | current |
| neHTAutoShutdown OBJECT-TYPE A system wide setting that specifies whether the circuit pack pack high temperature automatic shutdown (HTAS) is enabled. When enabled, the circuit packs which support the HTAS feature will be automatically powered down if the shutdown temperature threshold for that circuit pack is exceeded. There will be alarms indicating that the shutdown has occurred. The default setting is enabled. | 1.3.6.1.4.1.18070.2.2.1.1.15 | INTEGER {on(1), off(2)} | read-write | current |
| inventory OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.2 | |||
| shelfInvTable OBJECT-TYPE This table contains one row for every physically detected shelf on the NE. Each row contains a list of attributes that pertain to a physical shelf. | 1.3.6.1.4.1.18070.2.2.1.2.1 | not-accessible | current | |
| shelfInvEntry OBJECT-TYPE The conceptual row object of the shelf inventory table. | 1.3.6.1.4.1.18070.2.2.1.2.1.1 | not-accessible | current | |
| shelfInvIdx OBJECT-TYPE The number of the shelf. It is set to 1 for the main shelf, otherwise the object is based on the expansion shelf port on which the shelf is detected, and the number of hops from the main shelf. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| shelfInvExpectedNEName OBJECT-TYPE The NE name expected by the main shelf to be reported by the expansion shelf as the name of the NE to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.2 | DisplayString (SIZE(0..20)) | accessible-for-notify | current |
| shelfInvExpectedIPAddress OBJECT-TYPE The string representation of the NE NMS IP address that is expected by the main shelf to be reported by the expansion shelf as the IP address of the NE to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.3 | DisplayString (SIZE(0..15)) | accessible-for-notify | current |
| shelfInvExpectedShelfNum OBJECT-TYPE The number of the expansion shelf that is expected by the main shelf to be reported by the attached shelf. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.4 | INTEGER (11 | 21 | 31) | accessible-for-notify | current |
| shelfInvExpectedMSISerialNum OBJECT-TYPE The serial number of the Main Shelf Interface circuit pack that is expected by the main shelf to be reported by the expansion shelf as the MSI serial number of the NE main shelf to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.5 | DisplayString (SIZE(0..16)) | accessible-for-notify | current |
| shelfInvDiscoveredNEName OBJECT-TYPE The actual NE name reported by the expansion shelf as the name of the NE to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.6 | DisplayString (SIZE(0..20)) | accessible-for-notify | current |
| shelfInvDiscoveredIPAddress OBJECT-TYPE The string representation of the actual NE NMS IP address reported by the expansion shelf as the IP address of the NE to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.7 | DisplayString (SIZE(0..15)) | accessible-for-notify | current |
| shelfInvDiscoveredShelfNum OBJECT-TYPE The actual number of the expansion shelf reported by the attached shelf. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.8 | INTEGER (11 | 21 | 31) | accessible-for-notify | current |
| shelfInvDiscoveredMSISerialNum OBJECT-TYPE The actual serial number of the Main Shelf Interface circuit pack reported by the expansion shelf as the MSI serial number of the NE main shelf to which it belongs. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.9 | DisplayString (SIZE(0..16)) | accessible-for-notify | current |
| shelfInvType OBJECT-TYPE Indicates if the shelf functions as a main shelf or an expansion shelf. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.10 | ShelfType | read-only | current |
| shelfInvShortName OBJECT-TYPE A concise representation of the shelf brand name. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.11 | DisplayString (SIZE(0..8)) | read-only | current |
| shelfInvName OBJECT-TYPE The full representation of the shelf brand name. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.12 | DisplayString (SIZE(0..64)) | read-only | current |
| shelfInvChassisPEC OBJECT-TYPE A string representation of the Product Equipment Code for the shelf chassis alone. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.13 | DisplayString (SIZE(0..32)) | read-only | current |
| shelfInvChassisCLEI OBJECT-TYPE A string representation of the Telcordia Common Language Equipment Identifier for the shelf chassis alone. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.14 | DisplayString (SIZE(0..32)) | read-only | current |
| shelfInvAssemblyPEC OBJECT-TYPE A string representation of the Product Equipment Code for the shelf assembly, which bundles the shelf chassis, shelf interface pack, and cooling unit. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.15 | DisplayString (SIZE(0..32)) | read-only | obsolete |
| shelfInvRev OBJECT-TYPE The shelf hardware revision number. A value of 0 indicates that the revision is unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.16 | INTEGER (1..65535) | read-only | current |
| shelfInvConfig OBJECT-TYPE The shelf configuration with respect to the number of slots for holding replaceable circuit packs. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.17 | ShelfConfigType | read-only | deprecated |
| shelfInvUSI OBJECT-TYPE The Unique Serial Identifier (only for FNC-branded equipment) | 1.3.6.1.4.1.18070.2.2.1.2.1.1.18 | DisplayString (SIZE(0..32)) | read-only | current |
| shelfInvSerialNum OBJECT-TYPE The serial number of the unit. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.19 | DisplayString (SIZE(0..32)) | read-only | current |
| shelfInvMfgDate OBJECT-TYPE The shelf manufacture date in the format YYYY-MM-DD. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.20 | DisplayString (SIZE(0..16)) | read-only | current |
| shelfInvMfgLoc OBJECT-TYPE The shelf manufacture location. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.21 | DisplayString (SIZE(0..32)) | read-only | current |
| shelfInvTestDate OBJECT-TYPE The shelf test date in the format YYYY-MM-DD. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.22 | DisplayString (SIZE(0..16)) | read-only | current |
| shelfInvTestLoc OBJECT-TYPE The shelf test location. | 1.3.6.1.4.1.18070.2.2.1.2.1.1.23 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvTable OBJECT-TYPE This table contains one row for every slot on every shelf of the NE in which a circuit pack or other replaceable unit is seated. Each row contains a list of attributes that pertain to the circuit pack within the slot. | 1.3.6.1.4.1.18070.2.2.1.2.2 | not-accessible | current | |
| slotInvEntry OBJECT-TYPE The conceptual row object of the slot inventory table. | 1.3.6.1.4.1.18070.2.2.1.2.2.1 | not-accessible | current | |
| slotInvShelfIdx OBJECT-TYPE The number of the shelf on which the slot inventory item is detected. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| slotInvSlotTypeIdx OBJECT-TYPE The type of slot that contains the inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.2 | SlotType | accessible-for-notify | current |
| slotInvSlotIdx OBJECT-TYPE The number of the slot within the shelf containing the inventory item. The number is from 1 to 20 for regular circuit pack slots. For main shelf interface type slots, the number is set to 0. For 7060/7030/7020 expansion shelf interface and cooling unit type slots, the number is set to 0. For 7200 common communications module type slots, the number is 1 or 2. For 7200 cooling unit type slots, the number is from 1 to 4. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.3 | INTEGER (0..20) | accessible-for-notify | current |
| slotInvSWVersion OBJECT-TYPE The version of the software running on the circuit pack in the given slot. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.4 | DisplayString (SIZE(0..32)) | accessible-for-notify | current |
| slotInvPackShortName OBJECT-TYPE A concise representation of the name of the circuit pack or unit. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.5 | DisplayString (SIZE(0..8)) | read-only | current |
| slotInvPackName OBJECT-TYPE The full name of the circuit pack or unit. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.6 | DisplayString (SIZE(0..64)) | read-only | current |
| slotInvPackPEC OBJECT-TYPE The Product Equipment Code for the circuit pack or unit. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.7 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvPackCLEI OBJECT-TYPE The Telcordia Common Language Equipment Identifier for the circuit pack or unit. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.8 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvPackSerialNum OBJECT-TYPE The serial number of the unit. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.9 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvPackRev OBJECT-TYPE The circuit pack or unit hardware revision number. A value of 0 indicates that the revision is unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.10 | INTEGER (1..65535) | read-only | current |
| slotInvPackMfgDate OBJECT-TYPE The circuit pack manufacture date in the format YYYY-MM-DD. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.11 | DisplayString (SIZE(0..16)) | read-only | current |
| slotInvPackMfgLoc OBJECT-TYPE The circuit pack manufacture location. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.12 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvPackTestDate OBJECT-TYPE The circuit pack test date in the format YYYY-MM-DD. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.13 | DisplayString (SIZE(0..16)) | read-only | current |
| slotInvPackTestLoc OBJECT-TYPE The circuit pack test location. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.14 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvUpgradeStage OBJECT-TYPE The stage of the circuit pack upgrade process that has been completed. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.15 | UpgradeCompleteStage | accessible-for-notify | current |
| slotInvUpgradeResult OBJECT-TYPE Indicates if the identified stage of the circuit pack upgrade process has resulted in success or failure. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.16 | INTEGER {success(1), failure(2)} | accessible-for-notify | current |
| slotInvPackUSI OBJECT-TYPE The Unique Serial Identifier (only for FNC-branded equipment) | 1.3.6.1.4.1.18070.2.2.1.2.2.1.17 | DisplayString (SIZE(0..32)) | read-only | current |
| slotInvTempHighTh OBJECT-TYPE The circuit pack high temperature threshold. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.18 | INTEGER (1..65535) | read-only | current |
| slotInvTempShutdownTh OBJECT-TYPE The circuit pack shutdown temperature threshold. | 1.3.6.1.4.1.18070.2.2.1.2.2.1.19 | INTEGER (1..65535) | read-only | current |
| pluggableInvTable OBJECT-TYPE This table contains one row for every SFP/XFP or other pluggable present on any circuit pack or other replaceable unit present in the NE. Each row contains a list of attributes that pertain to the detected SFP/XFP. | 1.3.6.1.4.1.18070.2.2.1.2.3 | not-accessible | current | |
| pluggableInvEntry OBJECT-TYPE The conceptual row object of the pluggable inventory table. | 1.3.6.1.4.1.18070.2.2.1.2.3.1 | not-accessible | current | |
| pluggableInvShelfIdx OBJECT-TYPE The number of the shelf on which the pluggable inventory item resides. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| pluggableInvSlotTypeIdx OBJECT-TYPE The type of slot containing the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.2 | SlotType | accessible-for-notify | current |
| pluggableInvSlotIdx OBJECT-TYPE The number of the slot that contains the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| pluggableInvPortIdx OBJECT-TYPE The number of the port on the circuit pack that contains the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.4 | INTEGER (1..5) | accessible-for-notify | current |
| pluggableInvType OBJECT-TYPE The type of small form-factor pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.5 | INTEGER {unknown(1), sfp(2), xfp(3)} | read-only | current |
| pluggableInvPEC OBJECT-TYPE The Product Equipment Code for the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.6 | DisplayString (SIZE(0..32)) | read-only | current |
| pluggableInvCLEI OBJECT-TYPE The Telcordia Common Language Equipment Identifier for the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.7 | DisplayString (SIZE(0..32)) | read-only | current |
| pluggableInvVendorName OBJECT-TYPE The Vendor Name of the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.8 | DisplayString (SIZE(0..20)) | read-only | current |
| pluggableInvVendorOUI OBJECT-TYPE The Vendor IEEE Organizationally Unique Identifier. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.9 | DisplayString (SIZE(0..8)) | read-only | current |
| pluggableInvVendorPartNum OBJECT-TYPE The Vendor Part Number. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.10 | DisplayString (SIZE(0..20)) | read-only | current |
| pluggableInvVendorRev OBJECT-TYPE The Vendor Revision Number. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.11 | DisplayString (SIZE(0..8)) | read-only | current |
| pluggableInvVendorSerialNum OBJECT-TYPE The Vendor Serial Number. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.12 | DisplayString (SIZE(0..32)) | read-only | current |
| pluggableInvMfgDate OBJECT-TYPE The manufacture date in the format YYYY-MM-DD.. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.13 | DisplayString (SIZE(0..16)) | read-only | current |
| pluggableInvConnectorType OBJECT-TYPE The type of connector on the pluggable unit. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.14 | INTEGER {unknown(1), sc(2), fcs1cc(3), fcs2cc(4), bnctnc(5), fcch(6), fj(7), lc(8), mtrj(9), mu(10), sg(11), op(12), hssdc2(13), cp(14), vs(15)} | read-only | current |
| pluggableInvMinBitRate OBJECT-TYPE The minimum bit rate supported by the pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.15 | INTEGER (0..65535) | read-only | current |
| pluggableInvMaxBitRate OBJECT-TYPE The maximum bit rate supported by the pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.16 | INTEGER (0..65535) | read-only | current |
| pluggableInvNomBitRate OBJECT-TYPE The nominal bit rate supported by the pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.17 | INTEGER (0..65535) | read-only | current |
| pluggableInvEncoding OBJECT-TYPE A textual comma-delimited list of serial encoding mechanisms supported by the pluggable. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.18 | DisplayString (SIZE(0..64)) | read-only | current |
| pluggableInvWavelength OBJECT-TYPE The wavelength transmitted by the pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.19 | FixedX100 | read-only | current |
| pluggableInvReach OBJECT-TYPE The reach supported by the pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.20 | INTEGER (0..65535) | read-only | current |
| pluggableInvTxFaultImpl OBJECT-TYPE Indicates if the pluggable implements the Transmit Fault signal. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.21 | TruthValue | read-only | current |
| pluggableInvLOSImpl OBJECT-TYPE Indicates if the pluggable implements the Loss of Signal signal. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.22 | TruthValue | read-only | current |
| pluggableInvDDiagImpl OBJECT-TYPE Indicates if the pluggable implements support for Digital Diagnostics. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.23 | TruthValue | read-only | current |
| pluggableInvTxDisableImpl OBJECT-TYPE Indicates if the pluggable implements support for disabling the transmit laser. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.24 | TruthValue | read-only | current |
| pluggableInvMedia OBJECT-TYPE The physical media type of the pluggable | 1.3.6.1.4.1.18070.2.2.1.2.3.1.25 | INTEGER {unknown(1), electrical(2), optical(3)} | read-only | current |
| pluggableInvUSI OBJECT-TYPE The Unique Serial Identifier (only for FNC-branded equipment) | 1.3.6.1.4.1.18070.2.2.1.2.3.1.26 | DisplayString (SIZE(0..32)) | read-only | current |
| pluggableInvWavelengthMin OBJECT-TYPE The wavelength minimum for the tunable pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.27 | FixedX100 | read-only | current |
| pluggableInvWavelengthMax OBJECT-TYPE The wavelength maximum for the tunable pluggable.A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.28 | FixedX100 | read-only | current |
| pluggableInvWavelengthSpacing OBJECT-TYPE The wavelength spacing for the tunable pluggable. A value of 0 means unspecified. | 1.3.6.1.4.1.18070.2.2.1.2.3.1.29 | INTEGER (0 | 50 | 100) | read-only | current |
| slotInvDataTable OBJECT-TYPE This table contains a listing of any specialized data records available for the slot inventory entries on the system. Each row contains a single item of data for a specialized data record for a slot inventory entry. | 1.3.6.1.4.1.18070.2.2.1.2.4 | not-accessible | current | |
| slotInvDataEntry OBJECT-TYPE The conceptual row object of the slot inventory data table. | 1.3.6.1.4.1.18070.2.2.1.2.4.1 | not-accessible | current | |
| slotInvDataShelfIdx OBJECT-TYPE The number of the shelf on which the slot inventory item is detected. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| slotInvDataSlotTypeIdx OBJECT-TYPE The type of slot that contains the inventory item. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.2 | SlotType | not-accessible | current |
| slotInvDataSlotIdx OBJECT-TYPE The number of the slot within the shelf containing the inventory item. The number is from 1 to 20 for regular circuit pack slots. For shelfInterface and coolingUnit type slots, the number is set to 0. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.3 | INTEGER (0..20) | not-accessible | current |
| slotInvDataRecordIdx OBJECT-TYPE The specialized data record index. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.4 | Unsigned32 | not-accessible | current |
| slotInvDataNameIdx OBJECT-TYPE The name of the data item. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.5 | INTEGER {wavelength(1), loss(2), dispersion(3)} | not-accessible | current |
| slotInvDataValue OBJECT-TYPE The value of the data item. | 1.3.6.1.4.1.18070.2.2.1.2.4.1.6 | DisplayString | read-only | current |
| equipment OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.3 | |||
| shelfTable OBJECT-TYPE This table contains one row for every provisioned shelf on the NE. Each row contains a list of attributes that pertain to a provisioned shelf. | 1.3.6.1.4.1.18070.2.2.1.3.1 | not-accessible | current | |
| shelfEntry OBJECT-TYPE The conceptual row object of the shelf table. | 1.3.6.1.4.1.18070.2.2.1.3.1.1 | not-accessible | current | |
| shelfIdx OBJECT-TYPE The number of the shelf that has been provisioned. This is set to 1 for the main shelf. Otherwise, the number is based on the expansion shelf port number on which this shelf is expected to be detected and the number of hops from the main shelf. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| shelfProvConfig OBJECT-TYPE The provisioned configuration for the shelf. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.2 | ShelfConfigType | read-create | deprecated |
| shelfDiscConfig OBJECT-TYPE The configuration of the actual shelf discovered. Note: This object is no longer supported as of BTI 7000 Release 8.1.0, and is maintained in the MIB for backwards- compatibility for management of pre-8.1 nodes. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.3 | ShelfConfigType | accessible-for-notify | deprecated |
| shelfType OBJECT-TYPE Indicates if the provisioned shelf is a main or expansion shelf. Only expansion shelves can be created. The main shelf is automatically provisioned and can never be de-provisioned. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.4 | ShelfType | read-create | current |
| shelfPEC OBJECT-TYPE Indicates the provisioned shelf Product Equipment Code. This is a mandatory object when a row of the shelf table is created. The PEC can only be set at the time of row creation, and it cannot be edited later. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.5 | DisplayString (SIZE(1..32)) | read-create | current |
| shelfAdminStatus OBJECT-TYPE The administrative status of the shelf. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.6 | AdminStatus | read-create | current |
| shelfOperStatus OBJECT-TYPE The reported operational status of the shelf. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.7 | OperStatus | read-only | current |
| shelfOperStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported operational status of the shelf. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.8 | OperStatQlfr | read-only | current |
| shelfId OBJECT-TYPE Textual data recorded by the user to describe the provisioned shelf in a manner useful to the user such as the location where the shelf is installed. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.9 | DisplayString (SIZE(0..20)) | read-create | current |
| shelfCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.10 | DisplayString | read-create | current |
| shelfCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.11 | DisplayString | read-create | current |
| shelfCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.12 | DisplayString | read-create | current |
| shelfPowerFeedA OBJECT-TYPE The power feed mode for rail A. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.13 | PowerFeedModeType | read-create | current |
| shelfPowerFeedB OBJECT-TYPE The power feed mode for rail B. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.14 | PowerFeedModeType | read-create | current |
| shelfRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the shelf table, which in turn controls provisioning and deprovisioning of shelf objects. | 1.3.6.1.4.1.18070.2.2.1.3.1.1.100 | RowStatus | read-create | current |
| cpTable OBJECT-TYPE This table contains one row for every provisioned circuit pack on the NE. Each row contains a list of attributes that pertain to a provisioned circuit pack. | 1.3.6.1.4.1.18070.2.2.1.3.2 | not-accessible | current | |
| cpEntry OBJECT-TYPE The conceptual row object of the circuit pack table. | 1.3.6.1.4.1.18070.2.2.1.3.2.1 | not-accessible | current | |
| cpTypeIdx OBJECT-TYPE The specific type of circuit pack provisioned. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.1 | CpType | accessible-for-notify | current |
| cpShelfIdx OBJECT-TYPE The number of the shelf on which the circuit pack is provisioned. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.2 | INTEGER (0 | 1 | 11 | 21 | 31) | accessible-for-notify | current |
| cpSlotIdx OBJECT-TYPE The number of the slot in which the circuit pack is provisioned. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.3 | INTEGER (1..255) | accessible-for-notify | current |
| cpPEC OBJECT-TYPE Indicates the provisioned circuit pack Product Equipment Code. This is a mandatory object when a row of the circuit pack table is created. The PEC can only be set at the time of row creation, and it cannot be edited later. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.4 | DisplayString (SIZE(1..32)) | read-create | current |
| cpAdminStatus OBJECT-TYPE The administrative status of the circuit pack. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.5 | AdminStatus | read-create | current |
| cpOperStatus OBJECT-TYPE The reported operational status of the circuit pack. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.6 | OperStatus | read-only | current |
| cpOperStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported operational status of the circuit pack. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.7 | OperStatQlfr | read-only | current |
| cpId OBJECT-TYPE Textual data recorded by the user to describe the provisioned circuit pack in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.8 | DisplayString (SIZE(0..20)) | read-create | current |
| cpCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.9 | DisplayString | read-create | current |
| cpCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.10 | DisplayString | read-create | current |
| cpCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.11 | DisplayString | read-create | current |
| cpUpgradeStage OBJECT-TYPE Used in notifications sent during the circuit pack software upgrade process. It indicates the stage of the circuit pack upgrade process that has been completed. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.12 | UpgradeCompleteStage | accessible-for-notify | current |
| cpUpgradeResult OBJECT-TYPE Indicates if the identified stage of the circuit pack upgrade process has resulted in success or failure. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.13 | INTEGER {success(1), failure(2)} | accessible-for-notify | current |
| cpRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the circuit pack table, which in turn controls the provisioning and de-provisioning of circuit pack objects. | 1.3.6.1.4.1.18070.2.2.1.3.2.1.100 | RowStatus | read-create | current |
| facilities OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.4 | |||
| oaTable OBJECT-TYPE This table contains one row for every provisioned optical amplifier facility on the NE. Each row contains a list of attributes that pertain to the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1 | not-accessible | current | |
| oaEntry OBJECT-TYPE The conceptual row object of the optical amplifier table. | 1.3.6.1.4.1.18070.2.2.1.4.1.1 | not-accessible | current | |
| oaTypeIdx OBJECT-TYPE The specific type of optical amplifier provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.1 | OaType | accessible-for-notify | current |
| oaShelfIdx OBJECT-TYPE The number of the shelf on which the optical amplifier facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| oaSlotIdx OBJECT-TYPE The number of the slot in which the optical amplifier facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| oaIdx OBJECT-TYPE The number of the port on the circuit pack on which the optical amplifier facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.4 | INTEGER (1) | accessible-for-notify | current |
| oaCaseTempMaxTh OBJECT-TYPE The case temperature threshold. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.5 | INTEGER (-32768..32767) | read-create | current |
| oaCaseTempMaxShutdownTh OBJECT-TYPE The case temperature shutdown threshold. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.6 | INTEGER (-32768..32767) | read-only | current |
| oaLaserTempMinShutdownTh OBJECT-TYPE The laser temperature minimum shutdown threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.7 | INTEGER (-32768..32767) | read-only | current |
| oaLaserTempMaxShutdownTh OBJECT-TYPE The laser temperature maximum shutdown threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.8 | INTEGER (-32768..32767) | read-only | current |
| oaOpticalPwrReceivedMinTh OBJECT-TYPE The optical power received minimum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.9 | FixedX10 | read-create | current |
| oaOpticalPwrReceivedMaxTh OBJECT-TYPE The optical power received maximum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.10 | FixedX10 | read-create | current |
| oaSSIOpticalPwrReceivedMaxTh OBJECT-TYPE The secondary stage input optical power received maximum threshold. This object is applicable only to OLAM type amplifiers. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.11 | FixedX10 | read-create | current |
| oaOpticalPwrTransmittedMinTh OBJECT-TYPE The optical power transmitted minimum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.12 | FixedX10 | read-create | current |
| oaOpticalPwrTransmittedMaxTh OBJECT-TYPE The optical power transmitted maximum threshold. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.13 | FixedX10 | read-create | current |
| oaBackReflectionSafetyTh OBJECT-TYPE The optical back reflection safety threshold. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.14 | FixedX10 | read-only | current |
| oaMSInsertionLossMaxTh OBJECT-TYPE This is the mid-stage maximum insertion loss signal threshold. It applies to mid-stage access amplifiers only. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.15 | FixedX10 | read-create | current |
| oaCaseTemp OBJECT-TYPE The optical amplifier case temperature. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.16 | INTEGER (-32768..32767) | read-only | current |
| oaLaser1Temp OBJECT-TYPE The temperature of the optical amplifier laser 1. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.17 | INTEGER (-32768..32767) | read-only | current |
| oaLaser2Temp OBJECT-TYPE The temperature of the optical amplifier laser 2. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.18 | INTEGER (-32768..32767) | read-only | current |
| oaOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.19 | FixedX10 | read-only | current |
| oaSSIOpticalPwrReceived OBJECT-TYPE The optical power received on the second stage of the amplifier. It applies to mid-stage access amplifiers only. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.20 | FixedX10 | read-only | current |
| oaOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.21 | FixedX10 | read-only | current |
| oaMSInsertionLoss OBJECT-TYPE The mid-stage insertion loss. This object is only applicable to OLAM type amplifiers. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.22 | FixedX10 | read-only | current |
| oaEffectiveGain OBJECT-TYPE The effective gain level of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.33 | FixedX10 | read-only | current |
| oaFSOOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the first stage of the amplifier. It applies to mid-stage access amplifiers only. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.34 | FixedX10 | read-only | current |
| oaLaser1Current OBJECT-TYPE The optical amplifier laser 1 current. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.35 | FixedX10 | read-only | current |
| oaLaser2Current OBJECT-TYPE The optical amplifier laser 2 current. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.36 | FixedX10 | read-only | current |
| oaLaser1Power OBJECT-TYPE The optical amplifier laser 1 power. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.37 | FixedX10 | read-only | current |
| oaLaser2Power OBJECT-TYPE The optical amplifier laser 2 power. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.38 | FixedX10 | read-only | current |
| oaOpticalBackReflection OBJECT-TYPE The optical back reflection of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.39 | FixedX10 | read-only | current |
| oaVariableOpticalAttenuation OBJECT-TYPE The variable optical attenuation of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.40 | FixedX10 | read-only | current |
| oaAdminStatus OBJECT-TYPE The administrative status of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.41 | AdminStatus | read-create | current |
| oaOperStatus OBJECT-TYPE The reported operational status of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.42 | OperStatus | read-only | current |
| oaOperStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported operational status of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.43 | OperStatQlfr | read-only | current |
| oaAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted optical amplifier. This value only applies if the oaAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. The supported range of values is 000-00 to 096-00. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.44 | HoursAndMinutes | read-create | current |
| oaActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer, if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.45 | HoursAndMinutes | read-only | current |
| oaModeSetting OBJECT-TYPE The desired mode of operation to which this optical amplifier is set. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.46 | INTEGER {constantGain(2), constantPower(3)} | read-create | current |
| oaGainSetting OBJECT-TYPE The effective gain (excluding ASE) set point. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.47 | FixedX10 | read-create | current |
| oaPwrSetting OBJECT-TYPE The signal output power (excluding ASE) set point. A default value is provided when the optical amplifier is created based on the optical amplifier type provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.48 | FixedX10 | read-create | current |
| oaTiltCompSetting OBJECT-TYPE The desired tilt compensation to which this optical amplifier is set. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.49 | FixedX10 | read-create | current |
| oaStatus OBJECT-TYPE The specific operational status of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.50 | INTEGER {none(1), constantGain(2), constantPower(3), eyeSafe(4), shutdown(5), constantGainOff(6), constantPowerOff(7), constantLaserCurrent(8), constantLaserCurrentOff(9), constantLaserPower(10), constantLaserPowerOff(11)} | read-only | current |
| oaLaserStatus OBJECT-TYPE The actual operational status of the optical amplifier laser. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.51 | INTEGER {on(1), off(2)} | read-only | current |
| oaId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical amplifier in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.52 | DisplayString (SIZE(0..32)) | read-create | current |
| oaId2 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical amplifier in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.53 | DisplayString (SIZE(0..32)) | read-create | current |
| oaFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces with the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.54 | FiberType | read-create | current |
| oaGrid OBJECT-TYPE An optional indication of the WDM grid to which the link conforms. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.55 | WDMGrid | read-create | current |
| oaNumChannels OBJECT-TYPE An optional indication of the number of channels that the link is carrying. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.56 | INTEGER (0..40) | read-create | current |
| oaCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.57 | DisplayString | read-create | current |
| oaCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.58 | DisplayString | read-create | current |
| oaCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.59 | DisplayString | read-create | current |
| oaWavelength OBJECT-TYPE The wavelength transmitted from the OA port. This object applies only to single channel amplifiers (sba, spa). | 1.3.6.1.4.1.18070.2.2.1.4.1.1.60 | FixedX100 | read-create | current |
| oaRemoteId OBJECT-TYPE Identifies the remote node and port to which the optical amplifier port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.61 | DisplayString | read-create | current |
| oaRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the optical amplifier table, which in turn controls provisioning and deprovisioning of optical amplifier facilities. | 1.3.6.1.4.1.18070.2.2.1.4.1.1.100 | RowStatus | read-create | current |
| xcvrTable OBJECT-TYPE This table contains one row for every provisioned optical transceiver on a wavelength translator, regenerator or manager card. Each row contains a list of attributes that pertain to the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2 | not-accessible | current | |
| xcvrEntry OBJECT-TYPE The conceptual row object of the optical transceiver table. | 1.3.6.1.4.1.18070.2.2.1.4.2.1 | not-accessible | current | |
| xcvrTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the circuit pack on which the transceiver is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.1 | XcvrType | accessible-for-notify | current |
| xcvrShelfIdx OBJECT-TYPE The number of the shelf on which the transceiver is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| xcvrSlotIdx OBJECT-TYPE The number of the slot within which the transceiver is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| xcvrIdx OBJECT-TYPE The number of the port on the circuit pack on which the transceiver is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.4 | INTEGER (1..4) | accessible-for-notify | current |
| xcvrOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.5 | FixedX10 | read-only | current |
| xcvrOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.6 | FixedX10 | read-only | current |
| xcvrOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.7 | FixedX10 | read-only | current |
| xcvrOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.8 | FixedX10 | read-only | current |
| xcvrOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.9 | FixedX10 | accessible-for-notify | current |
| xcvrOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.10 | FixedX10 | accessible-for-notify | current |
| xcvrProtSwEvtType OBJECT-TYPE Indicates the type of protection switching event that has occured on an optical transceiver port. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.11 | ProtSwEvtType | accessible-for-notify | current |
| xcvrPEC OBJECT-TYPE An optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.12 | DisplayString (SIZE(0..32)) | read-create | current |
| xcvrAdminStatus OBJECT-TYPE The administrative status of the optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.13 | AdminStatus | read-create | current |
| xcvrOperStatus OBJECT-TYPE The reported operational status of the optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.14 | OperStatus | read-only | current |
| xcvrOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.15 | OperStatQlfr | read-only | current |
| xcvrAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted optical transceiver. This value only applies if the xcvrAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.16 | HoursAndMinutes | read-create | current |
| xcvrActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.17 | HoursAndMinutes | read-only | current |
| xcvrProtocol OBJECT-TYPE The protocol of the service to be carried by the port. This is a mandatory object when a row of the transceiver table is created. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.18 | XcvrProtocolType | read-create | current |
| xcvrWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver port. This is a mandatory object when a row of the transceiver table is created for ports that have a pluggable transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.19 | FixedX100 | read-create | current |
| xcvrVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the physically present transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| xcvrVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the physically present transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.21 | DisplayString (SIZE(0..20)) | read-create | current |
| xcvrVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the physically present transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.22 | DisplayString (SIZE(0..20)) | read-create | current |
| xcvrPhyPMMon OBJECT-TYPE Indicates if the port is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.23 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| xcvrFPSD OBJECT-TYPE Indicates if the port is configured for Fault Propagation Shut Down. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.24 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| xcvrLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.25 | INTEGER {on(1), off(2), idle(3), aisl(4), msais(5), odu2ais(6), prbs(7), remoteFault(8), odu2lck(9), odu2oci(10)} | read-only | current |
| xcvrId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.26 | DisplayString (SIZE(0..32)) | read-create | current |
| xcvrId2 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.27 | DisplayString (SIZE(0..32)) | read-create | current |
| xcvrFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.28 | FiberType | read-create | current |
| xcvrGrid OBJECT-TYPE An optical indication of the WDM grid the link conforms. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.29 | WDMGrid | read-create | current |
| xcvrCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.30 | DisplayString | read-create | current |
| xcvrCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.31 | DisplayString | read-create | current |
| xcvrCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.32 | DisplayString | read-create | current |
| xcvrTraceLabel OBJECT-TYPE If specified, this attribute will describe the trace label to be used in the outgoing OTN or SONET/SDH trace. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.33 | DisplayString (SIZE(0..16)) | read-create | current |
| xcvrExpectedTraceLabel OBJECT-TYPE This attribute will describe the trace label that is expected to be received in the incoming OTN or SONET/SDH trace. If specified, this expected trace label will be compared to the actual value for xcvrReceivedTraceLabel, and a trace mismatch alarm will be raised if the two trace labels do not match. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.34 | DisplayString (SIZE(0..16)) | read-create | current |
| xcvrReceivedTraceLabel OBJECT-TYPE The actual received trace label on the incoming OTN or SONET/SDH trace. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.35 | DisplayString (SIZE(0..16)) | read-only | current |
| xcvrSDBERTh OBJECT-TYPE The Bit Error Rate threshold above which the Signal Degrade condition is raised. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.36 | BERType | read-create | current |
| xcvrLoopbackType OBJECT-TYPE The loopback type that is currently active on the xcvr | 1.3.6.1.4.1.18070.2.2.1.4.2.1.37 | LoopbackType | read-only | current |
| xcvrRemoteId OBJECT-TYPE Identifies the remote node and port to which the transceiver port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.38 | DisplayString | read-create | current |
| xcvrRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the Transceiver table, which in turn controls provisioning and deprovisioning of optical transceiver facilities. | 1.3.6.1.4.1.18070.2.2.1.4.2.1.100 | RowStatus | read-create | current |
| amdTable OBJECT-TYPE This table contains one row for every provisioned active multiplexer-demultiplexer facility. AMD facilities include AMD line facilities and AMD channel facilities. Each row contains a list of attributes that pertain to one facility. | 1.3.6.1.4.1.18070.2.2.1.4.3 | not-accessible | obsolete | |
| amdEntry OBJECT-TYPE The conceptual row object of the Active Mux-Demux table. | 1.3.6.1.4.1.18070.2.2.1.4.3.1 | not-accessible | obsolete | |
| amdTypeIdx OBJECT-TYPE The specific type of active multiplexer-demultiplexer circuit pack on which the facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.1 | AmdType | accessible-for-notify | obsolete |
| amdShelfIdx OBJECT-TYPE The number of the shelf on which the active multiplexer-demultiplexer facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | obsolete |
| amdSlotIdx OBJECT-TYPE The number of the slot within which the active multiplexer-demultiplexer facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | accessible-for-notify | obsolete |
| amdLineIdx OBJECT-TYPE The number of the multiplexed wavelength line on the AMD circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.4 | INTEGER (1) | accessible-for-notify | obsolete |
| amdPortIdx OBJECT-TYPE Identifies a specific port on the identified line of the AMD circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.5 | AmdPortType | accessible-for-notify | obsolete |
| amdOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.6 | FixedX10 | read-write | obsolete |
| amdOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.7 | FixedX10 | read-write | obsolete |
| amdOpticalPwrTransmittedTarget OBJECT-TYPE This is the optical power transmitted target level. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.8 | FixedX10 | read-write | obsolete |
| amdOpticalAttenuationTarget OBJECT-TYPE This is the optical power attenuation target level. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.9 | FixedX10 | read-write | obsolete |
| amdOpticalPwrReceived OBJECT-TYPE The optical input power received for the channel. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.10 | FixedX10 | accessible-for-notify | obsolete |
| amdOpticalPwrTransmitted OBJECT-TYPE The optical power level transmitted for the channel. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.11 | FixedX10 | accessible-for-notify | obsolete |
| amdOpticalAttentuation OBJECT-TYPE The optical power attenuation for the line. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.12 | FixedX10 | accessible-for-notify | obsolete |
| amdAdminStatus OBJECT-TYPE The administrative status of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.13 | AdminStatus | read-write | obsolete |
| amdOperStatus OBJECT-TYPE The reported operational status of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.14 | OperStatus | read-only | obsolete |
| amdOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.15 | OperStatQlfr | read-only | obsolete |
| amdAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted AMD port. This value only applies if the amdAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.16 | HoursAndMinutes | read-write | obsolete |
| amdActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.17 | HoursAndMinutes | read-only | obsolete |
| amdWavelength OBJECT-TYPE The wavelength transmitted from the AMD port. This object applies only to channel ports. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.18 | FixedX100 | read-only | obsolete |
| amdId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.19 | DisplayString (SIZE(0..32)) | read-write | obsolete |
| amdId2 OBJECT-TYPE Textual data recorded by the user to describe the provisioned optical transceiver in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.20 | DisplayString (SIZE(0..32)) | read-write | obsolete |
| amdFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the AMD port. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.21 | FiberType | read-write | obsolete |
| amdGrid OBJECT-TYPE An optical indication of the WDM grid to which the AMD port link conforms. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.22 | WDMGrid | read-write | obsolete |
| amdCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.23 | DisplayString | read-write | obsolete |
| amdCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.24 | DisplayString | read-write | obsolete |
| amdCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.25 | DisplayString | read-write | obsolete |
| amdRowStatus OBJECT-TYPE The active multiplexer-demultiplexer table RowStatus object is not readable or writeable because all entries in the AMD table are automatically created and deleted when the AMD circuit pack is created or deleted. This AMD row status object is used only in database change notifications to indicate if the row has been created or deleted. | 1.3.6.1.4.1.18070.2.2.1.4.3.1.100 | RowStatus | accessible-for-notify | obsolete |
| passivePortTable OBJECT-TYPE This table contains one row for each port on every provisioned passive circuit pack on the NE. Each list contains a list of attributes that pertain to the passive port. | 1.3.6.1.4.1.18070.2.2.1.4.4 | not-accessible | current | |
| passivePortEntry OBJECT-TYPE The conceptual row object of the passive circuit pack port table. | 1.3.6.1.4.1.18070.2.2.1.4.4.1 | not-accessible | current | |
| passivePortCpTypeIdx OBJECT-TYPE The type of circuit pack on which the passive port is found. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.1 | CpType | not-accessible | current |
| passivePortShelfIdx OBJECT-TYPE The number of the shelf on which the passive circuit pack port is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| passivePortSlotIdx OBJECT-TYPE The number of the slot within which the passive circuit pack port is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.3 | INTEGER (1..20) | not-accessible | current |
| passivePortLineIdx OBJECT-TYPE Identifies the multiplexed multi-channel optical facility instance associated with the targeted passive port. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.4 | INTEGER (1..4) | not-accessible | current |
| passivePortTypeIdx OBJECT-TYPE Identifies the specific passive port on the circuit pack according to function. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.5 | PassivePortType | not-accessible | current |
| passivePortId1 OBJECT-TYPE An optional name used to identify the passive circuit pack port facility. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.6 | DisplayString (SIZE(0..32)) | read-write | current |
| passivePortId2 OBJECT-TYPE An optional identifier for the passive circuit pack port circuit. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.7 | DisplayString (SIZE(0..32)) | read-write | current |
| passivePortFiberType OBJECT-TYPE An optional specification of the fiber type interfacing the passive circuit pack port. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.8 | FiberType | read-write | current |
| passivePortGrid OBJECT-TYPE An optional indication of the DWM grid that the link conforms to. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.9 | WDMGrid | read-write | current |
| passivePortNumChannels OBJECT-TYPE An optional indication of the number of channels that the link is carrying. This field does not apply to individual channel type ports. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.10 | INTEGER (1..65536) | read-write | current |
| passivePortWavelength OBJECT-TYPE An indication of the wavelength that the port is carrying. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.11 | FixedX100 | read-only | current |
| passivePortCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.12 | DisplayString | read-write | current |
| passivePortCustom2 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.13 | DisplayString | read-write | current |
| passivePortCustom3 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.14 | DisplayString | read-write | current |
| passivePortRemoteId OBJECT-TYPE Identifies the remote node and port to which the passive card port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.15 | DisplayString | read-create | current |
| passivePortRowStatus OBJECT-TYPE The passive port table RowStatus object is not readable or writeable because all entries in the passive port table are automatically created and deleted when the circuit pack is created or deleted. This passive port row status object is used only in database change notifications to indicate if the row has been created or deleted. | 1.3.6.1.4.1.18070.2.2.1.4.4.1.100 | RowStatus | accessible-for-notify | current |
| ocnTable OBJECT-TYPE This table contains one row for every provisioned SONET OC-N facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.5 | not-accessible | current | |
| ocnEntry OBJECT-TYPE The conceptual row object of the OC-N table. | 1.3.6.1.4.1.18070.2.2.1.4.5.1 | not-accessible | current | |
| ocnTypeIdx OBJECT-TYPE The specific type of OC-N signal which is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.1 | OcnType | accessible-for-notify | current |
| ocnShelfIdx OBJECT-TYPE The number of the shelf on which the OC-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| ocnSlotIdx OBJECT-TYPE The number of the slot within which the OC-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| ocnPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.4 | INTEGER (1..6) | accessible-for-notify | current |
| ocnOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.5 | FixedX10 | read-only | current |
| ocnOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.6 | FixedX10 | read-only | current |
| ocnOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.7 | FixedX10 | read-only | current |
| ocnOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.8 | FixedX10 | read-only | current |
| ocnOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.9 | FixedX10 | accessible-for-notify | current |
| ocnOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.10 | FixedX10 | accessible-for-notify | current |
| ocnBER OBJECT-TYPE The Bit Error Rate measured on the received signal. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.11 | BERType | accessible-for-notify | current |
| ocnBERTh OBJECT-TYPE The Bit Error Rate threshold above which the Signal Degrade condition is raised. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.12 | BERType | read-create | current |
| ocnPEC OBJECT-TYPE An optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the OC-N port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.13 | DisplayString (SIZE(0..32)) | read-create | current |
| ocnAdminStatus OBJECT-TYPE The administrative status of the OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.14 | AdminStatus | read-create | current |
| ocnOperStatus OBJECT-TYPE The reported operational status of the OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.15 | OperStatus | read-only | current |
| ocnOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.16 | OperStatQlfr | read-only | current |
| ocnAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted OC-N facility. This value only applies if the ocnAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.17 | HoursAndMinutes | read-create | current |
| ocnActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.18 | HoursAndMinutes | read-only | current |
| ocnWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the OC-N facility port. This is a mandatory object when a row of the OC-N table is created. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.19 | FixedX100 | read-create | current |
| ocnVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| ocnVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.21 | DisplayString (SIZE(0..20)) | read-create | current |
| ocnVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.22 | DisplayString (SIZE(0..20)) | read-create | current |
| ocnPhyPMMon OBJECT-TYPE Indicates if the OC-N facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.23 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ocnLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.24 | INTEGER {on(1), off(2)} | read-only | current |
| ocnId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned OC-N facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.25 | DisplayString (SIZE(0..32)) | read-create | current |
| ocnFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.26 | FiberType | read-create | current |
| ocnCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.27 | DisplayString | read-create | current |
| ocnTOHTransparency OBJECT-TYPE Used to configure whether the transport overhead of the the SONET OC-N facility is to be handled transparently or if it is to be terminated and regenerated. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 and OC-3 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.28 | INTEGER {yes(1), no(2)} | read-create | current |
| ocnLineMapping OBJECT-TYPE Used to configure the OTN configuration of the line port. If set to unmapped, there is no OTN digital wrapper added to the OC-192 or OC-48 facility. The odu1ToOtu2 and otu2 mapping is applicable to OC-192 line ports as follows: odu1ToOtu2 - the line port is configured as an OTN digitally wrapped OTU2 facility containing 4 ODU1 units. otu2 - the line port is configured as an OTN digitally wrapped OTU2 facility to which an OC-192 facility is directly mapped. The subOdu1ToOtu1 and otu1 mapping is applicable to OC-48 line ports as follows: subOdu1ToOtu1 - the line port is configured as an OTN digitally wrapped ODU1 facility containing 4 sub-ODU1 units. otu1 - the line port is configured as an OTN digitally wrapped OTU1 facility to which an OC-48 facility is directly mapped. This object applies only to the OC-192 line port of the 10G MXP circuit pack and the OC-48 line port of the 8-port 2.5G circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.29 | INTEGER {unmapped(1), odu1ToOtu2(2), otu2(3), subOdu1ToOtu1(4), otu1(5)} | read-create | current |
| ocnProtSwEvtType OBJECT-TYPE Indicates the type of protection switching event that has occured on an OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.30 | ProtSwEvtType | accessible-for-notify | current |
| ocnDCCTransparency OBJECT-TYPE Used to configure whether the Data Communications Channel (DCC) is transported transparently through the circuit pack. Specifically, this refers to the D1, D2 and D3 section DCC bytes. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.31 | INTEGER {yes(1), no(2)} | read-create | current |
| ocnTransparencyChannel OBJECT-TYPE Used to configure the STS1 channel number on which the DCC is transported. This object only applies to OC-48 client facilities on the 10G MXP circuit pack and the OC-12 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.32 | INTEGER (1..48) | read-create | current |
| ocnRemoteId OBJECT-TYPE Identifies the remote node and port to which the OC-n port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.33 | DisplayString | read-create | current |
| ocnRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the OC-N table, which in turn controls provisioning and deprovisioning of OC-N facilities. | 1.3.6.1.4.1.18070.2.2.1.4.5.1.100 | RowStatus | read-create | current |
| stsnTable OBJECT-TYPE This table contains one row for every created SONET STS-N facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.6 | not-accessible | current | |
| stsnEntry OBJECT-TYPE The conceptual row object of the STS-N table. | 1.3.6.1.4.1.18070.2.2.1.4.6.1 | not-accessible | current | |
| stsnTypeIdx OBJECT-TYPE The specific type of STS-N signal which is created. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.1 | StsnType | accessible-for-notify | current |
| stsnShelfIdx OBJECT-TYPE The number of the shelf on which the STS-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| stsnSlotIdx OBJECT-TYPE The number of the slot within which the STS-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| stsnPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STS-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.4 | INTEGER (1..2) | accessible-for-notify | current |
| stsnIdx OBJECT-TYPE The stsn channel number within the port in which the STS-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.5 | INTEGER (1..192) | accessible-for-notify | current |
| stsnProtSwEvtType OBJECT-TYPE Indicates the type of protection switching event that has occured on an STS-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.6 | ProtSwEvtType | accessible-for-notify | current |
| stsnBER OBJECT-TYPE The Bit Error Rate measured on the received channel. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.7 | BERType | accessible-for-notify | current |
| stsnBERTh OBJECT-TYPE The Bit Error Rate threshold above which the Signal Degrade condition is raised. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.8 | BERType | accessible-for-notify | current |
| stsnProtSwStatus OBJECT-TYPE If the STS-N facility is configured as part of a protection grouping, this object indicates its protection status. | 1.3.6.1.4.1.18070.2.2.1.4.6.1.9 | OperStatQlfr | read-only | current |
| stmnTable OBJECT-TYPE This table contains one row for every provisioned SDH STM-N facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.7 | not-accessible | current | |
| stmnEntry OBJECT-TYPE The conceptual row object of the STM-N table. | 1.3.6.1.4.1.18070.2.2.1.4.7.1 | not-accessible | current | |
| stmnTypeIdx OBJECT-TYPE The specific type of STM-N signal which is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.1 | StmnType | accessible-for-notify | current |
| stmnShelfIdx OBJECT-TYPE The number of the shelf on which the STM-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| stmnSlotIdx OBJECT-TYPE The number of the slot within which the STM-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| stmnPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.4 | INTEGER (1..6) | accessible-for-notify | current |
| stmnOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.5 | FixedX10 | read-only | current |
| stmnOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.6 | FixedX10 | read-only | current |
| stmnOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.7 | FixedX10 | read-only | current |
| stmnOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.8 | FixedX10 | read-only | current |
| stmnOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.9 | FixedX10 | accessible-for-notify | current |
| stmnOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.10 | FixedX10 | accessible-for-notify | current |
| stmnBER OBJECT-TYPE The Bit Error Rate measured on the received signal. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.11 | BERType | accessible-for-notify | current |
| stmnBERTh OBJECT-TYPE The Bit Error Rate threshold above which the Signal Degrade condition is raised. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.12 | BERType | read-create | current |
| stmnPEC OBJECT-TYPE An optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the STM-N port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.13 | DisplayString (SIZE(0..32)) | read-create | current |
| stmnAdminStatus OBJECT-TYPE The administrative status of the STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.14 | AdminStatus | read-create | current |
| stmnOperStatus OBJECT-TYPE The reported operational status of the STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.15 | OperStatus | read-only | current |
| stmnOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.16 | OperStatQlfr | read-only | current |
| stmnAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted STM-N facility. This value only applies if the stmnAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.17 | HoursAndMinutes | read-create | current |
| stmnActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.18 | HoursAndMinutes | read-only | current |
| stmnWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the STM-N facility port. This is a mandatory object when a row of the STM-N table is created. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.19 | FixedX100 | read-create | current |
| stmnVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| stmnVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.21 | DisplayString (SIZE(0..20)) | read-create | current |
| stmnVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.22 | DisplayString (SIZE(0..20)) | read-create | current |
| stmnPhyPMMon OBJECT-TYPE Indicates if the STM-N facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.23 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| stmnLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.24 | INTEGER {on(1), off(2)} | read-only | current |
| stmnId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned STM-N facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.25 | DisplayString (SIZE(0..32)) | read-create | current |
| stmnFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.26 | FiberType | read-create | current |
| stmnCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.27 | DisplayString | read-create | current |
| stmnTOHTransparency OBJECT-TYPE Used to configure whether the transport overhead of the the SDH STM-N facility is to be handled transparently or if it is to be terminated and regenerated. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 and STM-1 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.28 | INTEGER {yes(1), no(2)} | read-create | current |
| stmnLineMapping OBJECT-TYPE Used to configure the OTN configuration of the line port. If set to unmapped, there is no OTN digital wrapper added to the STM-64 or STM-16 facility. The odu1ToOtu2 and otu2 mapping is applicable to STM-64 line ports as follows: odu1ToOtu2 - the line port is configured as an OTN digitally wrapped OTU2 facility containing 4 ODU1 units. otu2 - the line port is configured as an OTN digitally wrapped OTU2 facility to which an STM-64 facility is directly mapped. The subOdu1ToOtu1 and otu1 mapping is applicable to STM-16 line ports as follows: subOdu1ToOtu1 - the line port is configured as an OTN digitally wrapped ODU1 facility containing 4 sub-ODU1 units. otu1 - the line port is configured as an OTN digitally wrapped OTU1 facility to which an STM-16 facility is directly mapped. This object applies only to the STM-64 line port of the 10G MXP circuit pack and the STM-16 line port of the 8-port 2.5G circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.29 | INTEGER {unmapped(1), odu1ToOtu2(2), otu2(3), subOdu1ToOtu1(4), otu1(5)} | read-create | current |
| stmnProtSwEvtType OBJECT-TYPE Indicates the type of protection switching event that has occured on an STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.30 | ProtSwEvtType | accessible-for-notify | current |
| stmnDCCTransparency OBJECT-TYPE Used to configure whether the Data Communications Channel (DCC) is transported transparently through the circuit pack. Specifically, this refers to the D1, D2 and D3 section DCC bytes. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.31 | INTEGER {yes(1), no(2)} | read-create | current |
| stmnTransparencyChannel OBJECT-TYPE Used to configure the VC4 channel number on which the DCC is transported. This object only applies to STM-16 client facilities on the 10G MXP circuit pack and the STM-4 client facilities on the 8-port 2.5G MXP circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.32 | INTEGER (1..16) | read-create | current |
| stmnRemoteId OBJECT-TYPE Identifies the remote node and port to which the STM-n port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.33 | DisplayString | read-create | current |
| stmnRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the STM-N table, which in turn controls provisioning and deprovisioning of STM-N facilities. | 1.3.6.1.4.1.18070.2.2.1.4.7.1.100 | RowStatus | read-create | current |
| vcnTable OBJECT-TYPE This table contains one row for every created SDH VC-N facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.8 | not-accessible | current | |
| vcnEntry OBJECT-TYPE The conceptual row object of the VC-N table. | 1.3.6.1.4.1.18070.2.2.1.4.8.1 | not-accessible | current | |
| vcnTypeIdx OBJECT-TYPE The specific type of VC-N signal which is created. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.1 | VcnType | accessible-for-notify | current |
| vcnShelfIdx OBJECT-TYPE The number of the shelf on which the VC-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| vcnSlotIdx OBJECT-TYPE The number of the slot within which the VC-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| vcnPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the VC-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.4 | INTEGER (1..2) | accessible-for-notify | current |
| vcnIdx OBJECT-TYPE The vcn channel number within the port in which the VC-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.5 | INTEGER (1..64) | accessible-for-notify | current |
| vcnProtSwEvtType OBJECT-TYPE Indicates the type of protection switching event that has occured on a VC-N facility. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.6 | ProtSwEvtType | accessible-for-notify | current |
| vcnBER OBJECT-TYPE The Bit Error Rate measured on the received channel. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.7 | BERType | accessible-for-notify | current |
| vcnBERTh OBJECT-TYPE The Bit Error Rate threshold above which the Signal Degrade condition is raised. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.8 | BERType | accessible-for-notify | current |
| vcnProtSwStatus OBJECT-TYPE If the VC-N facility is configured as part of a protection grouping, this object indicates its protection status. | 1.3.6.1.4.1.18070.2.2.1.4.8.1.9 | OperStatQlfr | read-only | current |
| geTable OBJECT-TYPE This table contains one row for every provisioned Gigabit Ethernet (GE) facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.9 | not-accessible | current | |
| geEntry OBJECT-TYPE The conceptual row object of the GE table. | 1.3.6.1.4.1.18070.2.2.1.4.9.1 | not-accessible | current | |
| geShelfIdx OBJECT-TYPE The number of the shelf on which the GE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| geSlotIdx OBJECT-TYPE The number of the slot within which the GE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.2 | INTEGER (1..20) | accessible-for-notify | current |
| gePortIdx OBJECT-TYPE The number of the port on the circuit pack on which the GE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.3 | INTEGER (3..12) | accessible-for-notify | current |
| geOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.4 | FixedX10 | read-only | current |
| geOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.5 | FixedX10 | read-only | current |
| geOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.6 | FixedX10 | read-only | current |
| geOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.7 | FixedX10 | read-only | current |
| geOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.8 | FixedX10 | accessible-for-notify | current |
| geOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.9 | FixedX10 | accessible-for-notify | current |
| gePEC OBJECT-TYPE An optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver on the Gigabit Ethernet port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.10 | DisplayString (SIZE(0..32)) | read-create | current |
| geAdminStatus OBJECT-TYPE The administrative status of the Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.11 | AdminStatus | read-create | current |
| geOperStatus OBJECT-TYPE The reported operational status of the Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.12 | OperStatus | read-only | current |
| geOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.13 | OperStatQlfr | read-only | current |
| geAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted Gigabit Ethernet facility. This value only applies if the geAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.14 | HoursAndMinutes | read-create | current |
| geActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.15 | HoursAndMinutes | read-only | current |
| geWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the Gigabit Ethernet facility port. This is a mandatory object when a row of the Gigabit Ethernet table is created. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.16 | FixedX100 | read-create | current |
| geVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.17 | DisplayString (SIZE(0..20)) | read-create | current |
| geVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.18 | DisplayString (SIZE(0..20)) | read-create | current |
| geVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.19 | DisplayString (SIZE(0..20)) | read-create | current |
| gePhyPMMon OBJECT-TYPE Indicates if the Gigabit Ethernet facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.20 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| geFPSD OBJECT-TYPE Indicates if the Gigabit Ethernet facility is configured for Fault Propagation Shut Down. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.21 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| geLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.22 | INTEGER {on(1), off(2)} | read-only | current |
| geId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned Gigabit Ethernet facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.23 | DisplayString (SIZE(0..32)) | read-create | current |
| geFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.24 | FiberType | read-create | current |
| geCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.25 | DisplayString | read-create | current |
| geSpeed OBJECT-TYPE The speed of the Gigabit Ethernet facility link. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.26 | Gauge32 | read-only | current |
| geDuplex OBJECT-TYPE The duplex mode of the Gigabit Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.27 | DuplexModeType | read-only | current |
| geMediaRate OBJECT-TYPE The configured media rate of the Gigabit Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.28 | MediaRateType | read-create | current |
| geMTU OBJECT-TYPE The MTU size for the Gigabit Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.29 | Integer32 | read-only | current |
| geMACAddr OBJECT-TYPE The MAC address of the Gigabit Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.30 | MacAddress | read-only | current |
| geGfpMode OBJECT-TYPE Configures the mapping of GE facility port onto the line port using either framed or transparent general framing protocol. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.31 | INTEGER {unmapped(1), gfpf(2), gfpt(3)} | read-create | current |
| geFlowControl OBJECT-TYPE Configures the flow control setting of GE facility as transparent or locally enabled. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.32 | INTEGER {transparent(1), local(2)} | read-create | current |
| geRemoteId OBJECT-TYPE Identifies the remote node and port to which the gigabit ethernet port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.33 | DisplayString | read-create | current |
| geRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the Gigabit Ethernet table, which in turn controls provisioning and deprovisioning of Gigabit Ethernet facilities. | 1.3.6.1.4.1.18070.2.2.1.4.9.1.100 | RowStatus | read-create | current |
| feTable OBJECT-TYPE This table contains one row for every provisioned Fast Ethernet (FE) facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.10 | not-accessible | current | |
| feEntry OBJECT-TYPE The conceptual row object of the FE table. | 1.3.6.1.4.1.18070.2.2.1.4.10.1 | not-accessible | current | |
| feShelfIdx OBJECT-TYPE The number of the shelf on which the FE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| feSlotIdx OBJECT-TYPE The number of the slot within which the FE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.2 | INTEGER (1..20) | accessible-for-notify | current |
| fePortIdx OBJECT-TYPE The number of the port on the circuit pack on which the FE facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.3 | INTEGER (5..6) | accessible-for-notify | current |
| feId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned Fast Ethernet facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.4 | DisplayString (SIZE(0..32)) | read-create | current |
| feCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.5 | DisplayString | read-create | current |
| feSpeed OBJECT-TYPE The speed of the Fast Ethernet facility link. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.6 | Gauge32 | read-only | current |
| feDuplex OBJECT-TYPE The duplex mode of the Fast Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.7 | DuplexModeType | read-only | current |
| feMediaRate OBJECT-TYPE The configured media rate of the Fast Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.8 | MediaRateType | read-only | current |
| feMTU OBJECT-TYPE The MTU size for the Fast Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.9 | Integer32 | read-only | current |
| feMACAddr OBJECT-TYPE The MAC address of the Fast Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.10 | MacAddress | read-only | current |
| feRemoteId OBJECT-TYPE Identifies the remote node and port to which the fast ethernet port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.11 | DisplayString | read-create | current |
| feRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the Fast Ethernet table, which in turn controls provisioning and deprovisioning of Fast Ethernet facilities. | 1.3.6.1.4.1.18070.2.2.1.4.10.1.100 | RowStatus | read-create | current |
| vcgTable OBJECT-TYPE This table contains one row for every provisioned Virtual Concatenation Group (VCG) enitity on the system. Each row contains a list of attributes that pertain to the VCG. | 1.3.6.1.4.1.18070.2.2.1.4.11 | not-accessible | current | |
| vcgEntry OBJECT-TYPE The conceptual row object of the VCG table. | 1.3.6.1.4.1.18070.2.2.1.4.11.1 | not-accessible | current | |
| vcgShelfIdx OBJECT-TYPE The number of the shelf on which the VCG entity is located. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcgSlotIdx OBJECT-TYPE The number of the slot within which the VCG entity is located. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.2 | INTEGER (1..20) | not-accessible | current |
| vcgPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the VCG entity is located. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.3 | INTEGER (1..2) | not-accessible | current |
| vcgIdx OBJECT-TYPE The number of the VCG within the identified port. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.4 | INTEGER (1..255) | not-accessible | current |
| vcgType OBJECT-TYPE The format of the VCG. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.5 | INTEGER {sts1c21v(1), sts1c2v(2), sts3c7v(3), sts3c1v(4), vc47v(5), vc41v(6), sts1c3v(7), sts1c19v(8), sts1c22v(9), sts1c37v(10), sts1c74v(11), sts3c6v(12), sts3c12v(13), sts3c24v(14), vc46v(15), vc412v(16), vc424v(17), vc42v(18), sts1c6v(19), sts3c2v(20), sts1c31v(21), sts3c10v(22), vc410v(23)} | read-create | current |
| vcgTimeSlotIndices OBJECT-TYPE A textual listing of the time slot indices used for the VCG. The information is formatted as a comma-separated list of of individual time slot indices or time slot index ranges. For example, a value of 'X-Y,Z' indicates that the VCG includes all time slots in the range of X to Y, plus Z, when X, Y, and Z are all integers. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.6 | DisplayString (SIZE(1..511)) | read-create | current |
| vcgRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the VCG table, which in turn controls provisioning and deprovisioning of Virtual Concatenation groups. Manual creation and deletion of VCGs is supported only on the 10G MXP, as all VCGs on the 2.5G MXP are auto-created and deleted. | 1.3.6.1.4.1.18070.2.2.1.4.11.1.100 | RowStatus | read-create | current |
| fcTable OBJECT-TYPE This table contains one row for every provisioned fiber channel facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.12 | not-accessible | current | |
| fcEntry OBJECT-TYPE The conceptual row object of the fiber channel table. | 1.3.6.1.4.1.18070.2.2.1.4.12.1 | not-accessible | current | |
| fcShelfIdx OBJECT-TYPE The number of the shelf on which the fiber channel facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| fcSlotIdx OBJECT-TYPE The number of the slot within which the fiber channel facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | accessible-for-notify | current |
| fcPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the fiber channel facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.3 | INTEGER (3..12) | accessible-for-notify | current |
| fcRate OBJECT-TYPE The rate of the fiber channel signal which is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.4 | INTEGER {oneGbs(1), twoGbs(2), fourGbs(3)} | read-create | current |
| fcOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.5 | FixedX10 | read-only | current |
| fcOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.6 | FixedX10 | read-only | current |
| fcOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.7 | FixedX10 | read-only | current |
| fcOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.8 | FixedX10 | read-only | current |
| fcOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.9 | FixedX10 | accessible-for-notify | current |
| fcOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.10 | FixedX10 | accessible-for-notify | current |
| fcPEC OBJECT-TYPE An optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the fiber channel port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.11 | DisplayString (SIZE(0..32)) | read-create | current |
| fcAdminStatus OBJECT-TYPE The administrative status of the fiber channel facility. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.12 | AdminStatus | read-create | current |
| fcOperStatus OBJECT-TYPE The reported operational status of the fiber channel facility. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.13 | OperStatus | read-only | current |
| fcOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the fiber channel facility. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.14 | OperStatQlfr | read-only | current |
| fcAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted fiber channel facility. This value only applies if the fcAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.15 | HoursAndMinutes | read-create | current |
| fcActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.16 | HoursAndMinutes | read-only | current |
| fcWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the fiber channel facility port. This is a mandatory object when a row of the fiber channel table is created. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.17 | FixedX100 | read-create | current |
| fcVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.18 | DisplayString (SIZE(0..20)) | read-create | current |
| fcVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.19 | DisplayString (SIZE(0..20)) | read-create | current |
| fcVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the fiber channel facility port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| fcPhyPMMon OBJECT-TYPE Indicates if the fiber channel facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.21 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| fcFPSD OBJECT-TYPE Indicates if the Fiber Channel facility is configured for Fault Propagation Shut Down. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.22 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| fcLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the fiber channel facility port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.23 | INTEGER {on(1), off(2)} | read-only | current |
| fcId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned fiber channel facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.24 | DisplayString (SIZE(0..32)) | read-create | current |
| fcFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the fiber channel facility port. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.25 | FiberType | read-create | current |
| fcCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.26 | DisplayString | read-create | current |
| fcGfpMode OBJECT-TYPE Configures the mapping of fiber channel facility port onto the line port using GFP. Only the transparent mapping is supported for fiber channel facilities. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.27 | INTEGER {unmapped(1), gfpt(2)} | read-create | current |
| fcRemoteId OBJECT-TYPE Identifies the remote node and port to which the fiber channel port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.28 | DisplayString | read-create | current |
| fcRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the fiber channel table, which in turn controls provisioning and deprovisioning of fiber channel facilities. | 1.3.6.1.4.1.18070.2.2.1.4.12.1.100 | RowStatus | read-create | current |
| ethIntfTable OBJECT-TYPE This table contains one row for every provisioned Ethernet facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.14 | not-accessible | current | |
| ethIntfEntry OBJECT-TYPE The conceptual row object of the ethIntfTable table. | 1.3.6.1.4.1.18070.2.2.1.4.14.1 | not-accessible | current | |
| ethIntfShelfIdx OBJECT-TYPE The number of the shelf in which the Ethernet facility resides. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| ethIntfSlotIdx OBJECT-TYPE The number of the slot in which the Ethernet facility resides. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.2 | INTEGER (1..20) | accessible-for-notify | current |
| ethIntfPortTypeIdx OBJECT-TYPE The type of the port on the circuit pack. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.3 | PvxL1PortType | accessible-for-notify | current |
| ethIntfPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the ethernet facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.4 | INTEGER (1..24) | accessible-for-notify | current |
| ethIntfOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.5 | FixedX10 | read-only | current |
| ethIntfOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.6 | FixedX10 | read-only | current |
| ethIntfOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.7 | FixedX10 | read-only | current |
| ethIntfOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.8 | FixedX10 | read-only | current |
| ethIntfOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.9 | FixedX10 | accessible-for-notify | current |
| ethIntfOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.10 | FixedX10 | accessible-for-notify | current |
| ethIntfPEC OBJECT-TYPE An optionally provisioned transceiver Product Equipment Code used to validate the physically present transceiver on the Ethernet port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.11 | DisplayString (SIZE(0..32)) | read-create | current |
| ethIntfAdminStatus OBJECT-TYPE The administrative status of the Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.12 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ethIntfOperStatus OBJECT-TYPE The reported operational status of the Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.13 | OperStatus | read-only | current |
| ethIntfOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.14 | OperStatQlfr | read-only | current |
| ethIntfAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted Ethernet facility. This value only applies if the AdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.15 | HoursAndMinutes | read-create | current |
| ethIntfActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.16 | HoursAndMinutes | read-only | current |
| ethIntfWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the Gigabit Ethernet facility port. This is a mandatory object when a row of the Ethernet table is created. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.17 | FixedX100 | read-create | current |
| ethIntfVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.18 | DisplayString (SIZE(0..20)) | read-create | current |
| ethIntfVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.19 | DisplayString (SIZE(0..20)) | read-create | current |
| ethIntfVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| ethIntfPhyPMMon OBJECT-TYPE Indicates if the Ethernet facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.21 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ethIntfFPSD OBJECT-TYPE Indicates if the Ethernet facility is configured for Fault Propagation Shut Down. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.22 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ethIntfLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.23 | INTEGER {on(1), off(2)} | read-only | current |
| ethIntfId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.24 | DisplayString (SIZE(0..32)) | read-create | current |
| ethIntfFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.25 | FiberType | read-create | current |
| ethIntfCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.26 | DisplayString | read-create | current |
| ethIntfSpeed OBJECT-TYPE The speed of the Ethernet facility link. This object is mandatory to create a new facility and determines the type of interface, based on speed. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.27 | Gauge32 | read-only | current |
| ethIntfDuplex OBJECT-TYPE The duplex mode of the Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.28 | INTEGER {half(1), full(2), both(3)} | read-only | current |
| ethIntfMediaRate OBJECT-TYPE The configured media rate of the Ethernet facility interface. For 10 GE interfaces, the media rate can only be autoNegotiated. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.29 | MediaRateType | read-create | current |
| ethIntfMTU OBJECT-TYPE The MTU size for the Ethernet facility interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.30 | INTEGER (1518..9600) | read-create | current |
| ethIntfLinkStatus OBJECT-TYPE This object provides the link status information regarding the particular interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.31 | INTEGER {up(1), down(2)} | read-only | current |
| ethIntfLagId OBJECT-TYPE This object provides the information regarding the LAG Id of the particular interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.32 | INTEGER (1..10) | read-only | current |
| ethIntfLagPortPriority OBJECT-TYPE This object provides the information for lag port priority of the particular interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.33 | Integer32 | read-create | current |
| ethIntfBER OBJECT-TYPE The Signal Degrade Bit Error Ratio (SDBER) is used to configure the error rate threshold above which a Signal Degrade is declared. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.37 | BERType | read-create | current |
| ethIntfMACAddr OBJECT-TYPE The MAC address of the interface. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.39 | MacAddress | read-only | current |
| ethIntfLineMapping OBJECT-TYPE For 10 GE interfaces, both 10 GE LAN PHY and OTU2 encapsulated 10GE LAN PHY will be supported. The line mapping attribute allow provisioning of either of the protocol. This attributes applies to 10 GE interfaces only. When a 10 GE interface is configured as a stacking port, this field is set to stacking. NOTE: This parameter does not apply to gigabitEthernet type interfaces, attempts to set this for gigE port types will fail. Reading this object for non-10GigE interfaces will return notApplicable. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.40 | INTEGER {tenglanphy(1), otu2gfp1(2), notApplicable(3), stacking(4)} | read-create | current |
| ethIntfErrorCorrection OBJECT-TYPE For 10G in OTU2 line-mapping mode, this object specifies the error correction mode. For interfaces in tenlanphy line-mapping mode, this object must be none. Attempts to set it to any other value while in tenglanphy mode will fail. NOTE: This parameter does not apply to gigabitEthernet type interfaces, attempts to set this for gigE port types will fail. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.41 | INTEGER {none(1), fec(2), efec(3)} | read-create | current |
| ethIntfLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a transceiver facility as follows: - oprLpbk: operates a loopback on the transceiver - rlsLpbk: causes a previously invoked loopback to be released When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.42 | INTEGER {noOp(1), oprLpbk(2), rlsLpbk(3)} | read-write | current |
| ethIntfRemoteId OBJECT-TYPE Identifies the remote node and port to which the PVX ethernet port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.43 | DisplayString | read-create | current |
| ethIntfMirrorConfig OBJECT-TYPE Mirror configuration for the physical ethernet port | 1.3.6.1.4.1.18070.2.2.1.4.14.1.44 | MirrorConfigType | read-write | current |
| ethIntfLldpAdminStatus OBJECT-TYPE The administratively desired status of the local LLDP agent. If the associated ethIntfLldpAdminStatus object has a value of 'enabled(1)', then the LLDP agent will transmit and receive LLDP frames on this port. If the associated ethIntfLldpAdminStatus object has a value of 'disabled(2)', then LLDP agent will not transmit or receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in other tables, before the port's ethIntfLldpAdminStatus becomes disabled, then the information will naturally age out. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.45 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| ethIntfLldpRemChassisIdSubtype OBJECT-TYPE The type of encoding used to identify the chassis associated with the remote system. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.46 | LldpChassisIdSubtype | read-only | current |
| ethIntfLldpRemChassisId OBJECT-TYPE The string value used to identify the chassis component associated with the remote system. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.47 | LldpChassisId | read-only | current |
| ethIntfLldpRemPortIdSubtype OBJECT-TYPE The type of port identifier encoding used in the associated 'ethIntfLldpRemPortId' object. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.48 | LldpPortIdSubtype | read-only | current |
| ethIntfLldpRemPortId OBJECT-TYPE The string value used to identify the port component associated with the remote system. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.49 | LldpPortId | read-only | current |
| ethIntfBouncingStateChangeCount OBJECT-TYPE Count of the Ethernet facility operational state changes sinse last reboot | 1.3.6.1.4.1.18070.2.2.1.4.14.1.50 | Integer32 | read-only | current |
| ethIntfRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the Ethernet table, which in turn controls provisioning and deprovisioning of Ethernet facilities. | 1.3.6.1.4.1.18070.2.2.1.4.14.1.100 | RowStatus | read-create | current |
| odunTable OBJECT-TYPE This table contains one row for every ODU-N facility on the system. | 1.3.6.1.4.1.18070.2.2.1.4.15 | not-accessible | current | |
| odunEntry OBJECT-TYPE The conceptual row object of the ODU-N table. | 1.3.6.1.4.1.18070.2.2.1.4.15.1 | not-accessible | current | |
| odunTypeIdx OBJECT-TYPE The specific type of ODU-N which is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.15.1.1 | OdunType | accessible-for-notify | current |
| odunShelfIdx OBJECT-TYPE The number of the shelf on which the ODU-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.15.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| odunSlotIdx OBJECT-TYPE The number of the slot within which the ODU-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.15.1.3 | INTEGER (1..20) | accessible-for-notify | current |
| odunPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the ODU-N facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.15.1.4 | INTEGER (1..6) | accessible-for-notify | current |
| odunIdx OBJECT-TYPE The ODU-N channel number within the port in which the ODU-N facility exists. | 1.3.6.1.4.1.18070.2.2.1.4.15.1.5 | INTEGER (1..4) | accessible-for-notify | current |
| briTable OBJECT-TYPE This table contains one row for every provisioned Bit Rate Independent (BRI) facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.4.16 | not-accessible | current | |
| briEntry OBJECT-TYPE The conceptual row object of the BRI table. | 1.3.6.1.4.1.18070.2.2.1.4.16.1 | not-accessible | current | |
| briShelfIdx OBJECT-TYPE The number of the shelf on which the BRI facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| briSlotIdx OBJECT-TYPE The number of the slot within which the BRI facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | accessible-for-notify | current |
| briPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the BRI facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.3 | INTEGER (3..12) | accessible-for-notify | current |
| briProtocol OBJECT-TYPE The protocol of the BRI signal which is provisioned. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.4 | INTEGER {fx100(1), escon(2), sdSdi(3), hdSdi(4), hdSdi1001(5), dvbAsi(6)} | read-create | current |
| briOpticalPwrReceivedMinTh OBJECT-TYPE This is the optical power received minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.5 | FixedX10 | read-only | current |
| briOpticalPwrReceivedMaxTh OBJECT-TYPE This is the optical power received maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.6 | FixedX10 | read-only | current |
| briOpticalPwrTransmittedMinTh OBJECT-TYPE This is the optical power transmitted minimum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.7 | FixedX10 | read-only | current |
| briOpticalPwrTransmittedMaxTh OBJECT-TYPE This is the optical power transmitted maximum threshold. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.8 | FixedX10 | read-only | current |
| briOpticalPwrReceived OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.9 | FixedX10 | accessible-for-notify | current |
| briOpticalPwrTransmitted OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.10 | FixedX10 | accessible-for-notify | current |
| briPEC OBJECT-TYPE An optionally provisioned Product Equipment Code used to validate the physically present optical transceiver on the BRI port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.11 | DisplayString (SIZE(0..32)) | read-create | current |
| briAdminStatus OBJECT-TYPE The administrative status of the BRI facility. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.12 | AdminStatus | read-create | current |
| briOperStatus OBJECT-TYPE The reported operational status of the BRI facility. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.13 | OperStatus | read-only | current |
| briOperStatQlfr OBJECT-TYPE This is a textual list of qualifiers about the reported operational status of the BRI facility. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.14 | OperStatQlfr | read-only | current |
| briAutoEnableTimer OBJECT-TYPE Specifies the auto-enable timer for the targeted BRI facility. This value only applies if the briAdminStatus object is set to autoEnabled. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.15 | HoursAndMinutes | read-create | current |
| briActAutoEnableTimer OBJECT-TYPE Indicates the time remaining on the auto-enable timer if it is actively counting down. Otherwise, the value returned is 000-00. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.16 | HoursAndMinutes | read-only | current |
| briWavelength OBJECT-TYPE The wavelength to be transmitted by the transceiver on the BRI facility port. This is a mandatory object when a row of the fiber channel table is created. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.17 | FixedX100 | read-create | current |
| briVendorPN1 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.18 | DisplayString (SIZE(0..20)) | read-create | current |
| briVendorPN2 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.19 | DisplayString (SIZE(0..20)) | read-create | current |
| briVendorPN3 OBJECT-TYPE An optionally provisioned part number used to validate the optical transceiver on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.20 | DisplayString (SIZE(0..20)) | read-create | current |
| briPhyPMMon OBJECT-TYPE Indicates if the BRI facility is configured to report threshold crossing conditions for physical layer performance monitoring parameters. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.21 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| briLaserStatus OBJECT-TYPE An indication of the operational status of the transceiver laser on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.22 | INTEGER {on(1), off(2)} | read-only | current |
| briId1 OBJECT-TYPE Textual data recorded by the user to describe the provisioned BRI facility in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.23 | DisplayString (SIZE(0..32)) | read-create | current |
| briFiberType OBJECT-TYPE An optional specification of the fiber type that interfaces to the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.24 | FiberType | read-create | current |
| briCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.25 | DisplayString | read-create | current |
| briBitRate OBJECT-TYPE The bit rate transmitted by the BRI facility port in Mbps. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.26 | FixedX100 | read-only | current |
| briRemoteId OBJECT-TYPE Identifies the remote node and port to which the Bitrate Independent port is connected, in the format prescribed by the PSM network management system. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.27 | DisplayString | read-create | current |
| briRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the BRI table, which in turn controls provisioning and deprovisioning of BRI facilities. | 1.3.6.1.4.1.18070.2.2.1.4.16.1.100 | RowStatus | read-create | current |
| dataComms OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.5 | |||
| oscTable OBJECT-TYPE This table contains one row for every provisioned optical supervisory channel interface on the NE. Each row contains a list of attributes that pertain to the OSC. | 1.3.6.1.4.1.18070.2.2.1.5.1 | not-accessible | current | |
| oscEntry OBJECT-TYPE The conceptual row object of the optical supervisory channel table. | 1.3.6.1.4.1.18070.2.2.1.5.1.1 | not-accessible | current | |
| oscShelfIdx OBJECT-TYPE The number of the shelf on which the OSC is provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.1 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| oscSlotIdx OBJECT-TYPE The number of the slot in which the OSC is provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.2 | INTEGER (1..20) | accessible-for-notify | current |
| oscIdx OBJECT-TYPE The number of the port on the circuit pack on which the OSC is provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.3 | INTEGER (1..2) | accessible-for-notify | current |
| oscAdminStatus OBJECT-TYPE The administrative status of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.4 | AdminStatus | read-create | current |
| oscOperStatus OBJECT-TYPE The reported operational status of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.5 | OperStatus | read-only | current |
| oscOperStatQlfr OBJECT-TYPE A textual list of qualifiers for the reported operational status of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.6 | OperStatQlfr | read-only | current |
| oscCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.7 | DisplayString | read-create | current |
| oscType OBJECT-TYPE The type of physical communication medium attached to the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.8 | INTEGER {optical(1), electrical(2), logical(3)} | read-only | current |
| oscUnmbrd OBJECT-TYPE Indicates whether or not the OSC interface is the type that requires an IP address to be assigned. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.9 | TruthValue | read-only | current |
| oscSpeed OBJECT-TYPE The speed of the OSC link. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.10 | Gauge32 | read-only | current |
| oscDuplex OBJECT-TYPE The duplex mode of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.11 | DuplexModeType | read-only | current |
| oscMediaRate OBJECT-TYPE The configured media rate of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.12 | MediaRateType | read-only | current |
| oscMTU OBJECT-TYPE The MTU size for the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.13 | Integer32 | read-only | current |
| oscMACAddr OBJECT-TYPE The MAC address of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.14 | MacAddress | read-only | current |
| oscIPAddr OBJECT-TYPE The IP Address of the OSC interface. A value of 0.0.0.0 indicates that the interface is not assigned an IP address. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.15 | IpAddress | read-create | current |
| oscIPMask OBJECT-TYPE The IP Subnet Mask of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.16 | IpAddress | read-create | current |
| oscIPBcast OBJECT-TYPE The IP broadcast address of the OSC interface. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.17 | IpAddress | read-only | current |
| oscRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the OSC table, which in turn controls provisioning and deprovisioning of OSC interfaces. | 1.3.6.1.4.1.18070.2.2.1.5.1.1.100 | RowStatus | read-create | current |
| netMgmtTable OBJECT-TYPE This table contains one row for every network management interface on the NE. Each row contains a list of attributes that pertain to the interface. | 1.3.6.1.4.1.18070.2.2.1.5.2 | not-accessible | current | |
| netMgmtEntry OBJECT-TYPE The conceptual row object of the network management interface table. | 1.3.6.1.4.1.18070.2.2.1.5.2.1 | not-accessible | current | |
| netMgmtIdx OBJECT-TYPE Identifies the specific management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.1 | INTEGER {nms(1), craft(2)} | not-accessible | current |
| netMgmtAdminStatus OBJECT-TYPE The administrative status of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.2 | AdminStatus | read-write | current |
| netMgmtOperStatus OBJECT-TYPE The reported operational status of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.3 | OperStatus | read-only | current |
| netMgmtOperStatQlfr OBJECT-TYPE A textual list of qualifiers for the reported operational status of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.4 | OperStatQlfr | read-only | current |
| netMgmtIPAddr OBJECT-TYPE The IP Address of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.5 | IpAddress | read-write | current |
| netMgmtIPMask OBJECT-TYPE The IP Subnet Mask of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.6 | IpAddress | read-write | current |
| netMgmtIPBcast OBJECT-TYPE The IP broadcast address of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.7 | IpAddress | read-only | current |
| netMgmtCustom1 OBJECT-TYPE A variable length text string for operating company use. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.8 | DisplayString | read-write | current |
| netMgmtType OBJECT-TYPE The type of physical communication medium attached to the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.9 | INTEGER {optical(1), electrical(2), logical(3)} | read-only | current |
| netMgmtUnmbrd OBJECT-TYPE Indicates whether or not the management interface is the type that requires an IP address to be assigned. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.10 | TruthValue | read-only | current |
| netMgmtSpeed OBJECT-TYPE The speed of the management interface link. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.11 | Gauge32 | read-only | current |
| netMgmtDuplex OBJECT-TYPE The duplex mode of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.12 | DuplexModeType | read-only | current |
| netMgmtMediaRate OBJECT-TYPE The configured media rate of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.13 | MediaRateType | read-only | current |
| netMgmtMTU OBJECT-TYPE The MTU size for this management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.14 | Integer32 | read-only | current |
| netMgmtMACAddr OBJECT-TYPE The MAC address of the management interface. | 1.3.6.1.4.1.18070.2.2.1.5.2.1.15 | MacAddress | read-only | current |
| serialTable OBJECT-TYPE A table of serial communication ports on the network element. Each row contains a list of attributes that pertain to a given serial port. | 1.3.6.1.4.1.18070.2.2.1.5.3 | not-accessible | current | |
| serialEntry OBJECT-TYPE The conceptual row object for the serial port table. | 1.3.6.1.4.1.18070.2.2.1.5.3.1 | not-accessible | current | |
| serialPortIdx OBJECT-TYPE The serial port instance on the NE. | 1.3.6.1.4.1.18070.2.2.1.5.3.1.1 | INTEGER (1) | not-accessible | current |
| serialBaudRate OBJECT-TYPE The baud rate of the serial port. | 1.3.6.1.4.1.18070.2.2.1.5.3.1.2 | Unsigned32 | read-write | current |
| serialDataBits OBJECT-TYPE The number of data bits of the serial port. | 1.3.6.1.4.1.18070.2.2.1.5.3.1.3 | INTEGER (1..255) | read-write | current |
| serialParity OBJECT-TYPE The parity value of the serial port. | 1.3.6.1.4.1.18070.2.2.1.5.3.1.4 | INTEGER {none(1), odd(2), even(3)} | read-write | current |
| serialStopBits OBJECT-TYPE The number of stop bits of the serial port. | 1.3.6.1.4.1.18070.2.2.1.5.3.1.5 | INTEGER {one(1), two(2)} | read-write | current |
| gcc0ConfigTable OBJECT-TYPE A table of GCC0 configuration information. This table contains one row for every provisioned GCC0. | 1.3.6.1.4.1.18070.2.2.1.5.4 | not-accessible | current | |
| gcc0ConfigEntry OBJECT-TYPE A conceptual row that contains GCC0 configuration information of an interface. Each instance must correspond to an instance of an OTN Port capable of supporting GCC. Instances of this conceptual row persist across agent restarts. | 1.3.6.1.4.1.18070.2.2.1.5.4.1 | not-accessible | current | |
| gcc0ConfigCpTypeIdx OBJECT-TYPE The specific type of circuit pack provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.1 | CpType | not-accessible | current |
| gcc0ConfigShelfIdx OBJECT-TYPE The number of the shelf on which the gcc0 is provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| gcc0ConfigSlotIdx OBJECT-TYPE The number of the slot in which the gcc0 is provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.3 | INTEGER (1..20) | not-accessible | current |
| gcc0ConfigPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the gcc0 provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.4 | INTEGER (1..4) | not-accessible | current |
| gcc0ConfigMode OBJECT-TYPE The desired mode to which the gcc0 is to be provisioned. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.5 | INTEGER {fullRate(1), lowRate(2)} | read-create | current |
| gcc0ConfigAdminStatus OBJECT-TYPE The administrative status of the gcc. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.6 | AdminStatus | read-create | current |
| gcc0ConfigOperStatus OBJECT-TYPE The reported operational status of the gcc. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.7 | OperStatus | read-only | current |
| gcc0ConfigOperStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported operational status of the gcc. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.8 | OperStatQlfr | read-only | current |
| gcc0ConfigRowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the gcc0 config table. | 1.3.6.1.4.1.18070.2.2.1.5.4.1.9 | RowStatus | read-create | current |
| ipExtInterfaceTable OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5 | not-accessible | current | |
| ipExtInterfaceTableEntry OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5.1 | not-accessible | current | |
| pvxL2IntfSubPortNumber OBJECT-TYPE A number indentifying a entity smaller than and contained in a port. At this time, this value is unused and must be zero. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.1 | Integer32 | not-accessible | current |
| ipExtIntfPrimaryState OBJECT-TYPE The reported operational status of the IP Interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.2 | OperStatus | read-only | current |
| ipExtIntfSecondaryState OBJECT-TYPE A textual list of qualifiers for the reported operational status of the IP Interface | 1.3.6.1.4.1.18070.2.2.1.5.5.1.3 | OperStatQlfr | read-only | current |
| ipExtIntfCmdPrimaryState OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5.1.4 | OperStatus | read-only | current |
| ipExtIntfNumberedStatus OBJECT-TYPE Set to true if this is a numbered interface and false if it is unnumbered. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.5 | TruthValue | read-create | current |
| ipExtIntfAddressType OBJECT-TYPE The type of addresses (v4/v6) used in this row of this MIB. Currently only ipv4 is allowed in this table. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.6 | InetAddressType | read-only | current |
| ipExtIntfAddress OBJECT-TYPE The IP Address associated with the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.7 | InetAddress | read-only | current |
| ipExtIntfSubnetMask OBJECT-TYPE The sub-net mask associated with the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.8 | InetAddress | read-only | current |
| ipExtIntfProxyARPStatus OBJECT-TYPE Not currently implemented. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.9 | TruthValue | read-only | current |
| ipExtIntfDescription OBJECT-TYPE A string describing the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.10 | DisplayString (SIZE(0..255)) | read-only | current |
| ipExtIntfMACAddr OBJECT-TYPE The MAC address associated with the interface, if applicable. All zeros for a non-MAC interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.11 | MacAddress | read-only | current |
| ipExtIntfOperStatus OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5.1.12 | OperStatus | read-only | current |
| ipExtIntfType OBJECT-TYPE A value describing the type of interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.13 | INTEGER {optical(1), electrical(2), logical(3)} | read-only | current |
| ipExtIntfBroadcastAddress OBJECT-TYPE The broadcast address associated with the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.14 | InetAddress | read-only | current |
| ipExtIntfSpeed OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5.1.15 | Gauge32 | read-only | current |
| ipExtIntfMode OBJECT-TYPE Is the interface full or half-duplex? | 1.3.6.1.4.1.18070.2.2.1.5.5.1.16 | DuplexModeType | read-only | current |
| ipExtIntfMTUSize OBJECT-TYPE The Maximum Transmission Unit for the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.17 | Integer32 | read-only | current |
| ipExtIntfLastChange OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.5.5.1.18 | Integer32 | read-only | current |
| ipExtIntfGateway OBJECT-TYPE The gateway IP address associated with the interface. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.19 | InetAddress | read-only | current |
| ipExtIntfRowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the ipExtIntf table. | 1.3.6.1.4.1.18070.2.2.1.5.5.1.100 | RowStatus | read-only | current |
| performance OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.6 | |||
| oaCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the optical amplifier facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.1 | not-accessible | current | |
| oaCrntPMEntry OBJECT-TYPE The row entry object of the optical amplifier current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1 | not-accessible | current | |
| oaCrntPMOaTypeIdx OBJECT-TYPE The type of the optical amplifier targeted for PM retrieval. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.1 | OaType | not-accessible | current |
| oaCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the amplifier targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| oaCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the optical amplifier targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.3 | INTEGER (1..20) | not-accessible | current |
| oaCrntPMOaIdx OBJECT-TYPE The number of the amplifier port on which the circuit pack for PMs is targeted. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.4 | INTEGER (1) | not-accessible | current |
| oaCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.5 | PMIntervalType | not-accessible | current |
| oaCrntPMCaseTempValue OBJECT-TYPE The optical amplifier case temperature. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.6 | INTEGER (-32768..32767) | read-only | current |
| oaCrntPMCaseTempTimeStamp OBJECT-TYPE The date and time stamp of the case temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.7 | DateAndTime | read-only | current |
| oaCrntPMCaseTempValidity OBJECT-TYPE Indicates the validity of the provided case temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.8 | PMValidity | read-only | current |
| oaCrntPMLaser1TempValue OBJECT-TYPE The optical amplifier laser 1 temperature. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.9 | INTEGER (-32768..32767) | read-only | current |
| oaCrntPMLaser1TempTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.10 | DateAndTime | read-only | current |
| oaCrntPMLaser1TempValidity OBJECT-TYPE Indicates the validity of the provided laser 1 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.11 | PMValidity | read-only | current |
| oaCrntPMLaser2TempValue OBJECT-TYPE The optical amplifier laser 2 temperature. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.12 | INTEGER (-32768..32767) | read-only | current |
| oaCrntPMLaser2TempTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.13 | DateAndTime | read-only | current |
| oaCrntPMLaser2TempValidity OBJECT-TYPE Indicates the validity of the provided laser 2 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.14 | PMValidity | read-only | current |
| oaCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the amplifer. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.15 | FixedX10 | read-only | current |
| oaCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.16 | DateAndTime | read-only | current |
| oaCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.17 | PMValidity | read-only | current |
| oaCrntPMSSIOPRValue OBJECT-TYPE The optical power received on the input of the second stage of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.18 | FixedX10 | read-only | current |
| oaCrntPMSSIOPRTimeStamp OBJECT-TYPE The date and time stamp of the second stage input optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.19 | DateAndTime | read-only | current |
| oaCrntPMSSIOPRValidity OBJECT-TYPE Indicates the validity of the provided second stage input optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.20 | PMValidity | read-only | current |
| oaCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.21 | FixedX10 | read-only | current |
| oaCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.22 | DateAndTime | read-only | current |
| oaCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.23 | PMValidity | read-only | current |
| oaCrntPMMSInsLossValue OBJECT-TYPE The mid-stage insertion loss. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.24 | FixedX10 | read-only | current |
| oaCrntPMMSInsLossTimeStamp OBJECT-TYPE The date and time stamp of the mid-stage insertion loss value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.25 | DateAndTime | read-only | current |
| oaCrntPMMSInsLossValidity OBJECT-TYPE Indicates the validity of the provided mid-stage insertion loss value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.26 | PMValidity | read-only | current |
| oaCrntPMEffectiveGainValue OBJECT-TYPE The effective gain of the optical amplifier. This reading is compensated for amplified spontaneous emissions. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.27 | FixedX10 | read-only | current |
| oaCrntPMEffectiveGainTimeStamp OBJECT-TYPE The date and time stamp of the effective gain value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.28 | DateAndTime | read-only | current |
| oaCrntPMEffectiveGainValidity OBJECT-TYPE Indicates the validity of the provided effective gain value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.29 | PMValidity | read-only | current |
| oaCrntPMFSOOPTValue OBJECT-TYPE The optical power transmitted at the output of the first stage of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.30 | FixedX10 | read-only | current |
| oaCrntPMFSOOPTTimeStamp OBJECT-TYPE The date and time stamp of the first stage output optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.31 | DateAndTime | read-only | current |
| oaCrntPMFSOOPTValidity OBJECT-TYPE Indicates the validity of the provided first stage output optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.32 | PMValidity | read-only | current |
| oaCrntPMLaser1CurrentValue OBJECT-TYPE The optical amplifier laser 1 current. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.33 | FixedX10 | read-only | current |
| oaCrntPMLaser1CurrentTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 current value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.34 | DateAndTime | read-only | current |
| oaCrntPMLaser1CurrentValidity OBJECT-TYPE Indicates the validity of the provided laser 1 current value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.35 | PMValidity | read-only | current |
| oaCrntPMLaser2CurrentValue OBJECT-TYPE The optical amplifier laser 2 current. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.36 | FixedX10 | read-only | current |
| oaCrntPMLaser2CurrentTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 current value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.37 | DateAndTime | read-only | current |
| oaCrntPMLaser2CurrentValidity OBJECT-TYPE Indicates the validity of the provided laser 2 current value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.38 | PMValidity | read-only | current |
| oaCrntPMLaser1PowerValue OBJECT-TYPE The optical amplifier laser 1 power. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.39 | FixedX10 | read-only | current |
| oaCrntPMLaser1PowerTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 power value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.40 | DateAndTime | read-only | current |
| oaCrntPMLaser1PowerValidity OBJECT-TYPE Indicates the validity of the provided laser 1 power value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.41 | PMValidity | read-only | current |
| oaCrntPMLaser2PowerValue OBJECT-TYPE The optical amplifier laser 2 power. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.42 | FixedX10 | read-only | current |
| oaCrntPMLaser2PowerTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 power value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.43 | DateAndTime | read-only | current |
| oaCrntPMLaser2PowerValidity OBJECT-TYPE Indicates the validity of the provided laser 2 power value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.44 | PMValidity | read-only | current |
| oaCrntPMOBRValue OBJECT-TYPE The back reflected optical power measured at the output of the second stage of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.45 | FixedX10 | read-only | current |
| oaCrntPMOBRTimeStamp OBJECT-TYPE The date and time stamp of the optical back reflection value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.46 | DateAndTime | read-only | current |
| oaCrntPMOBRValidity OBJECT-TYPE Indicates the validity of the provided optical back reflection value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.47 | PMValidity | read-only | current |
| oaCrntPMVOAValue OBJECT-TYPE The variable optical attenuation of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.48 | FixedX10 | read-only | current |
| oaCrntPMVOATimeStamp OBJECT-TYPE The date and time stamp of the variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.49 | DateAndTime | read-only | current |
| oaCrntPMVOAValidity OBJECT-TYPE Indicates the validity of the provided variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.1.1.50 | PMValidity | read-only | current |
| oaHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the optical amplifier facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.2 | not-accessible | current | |
| oaHistPMEntry OBJECT-TYPE The row entry object of the optical amplifier historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1 | not-accessible | current | |
| oaHistPMOaTypeIdx OBJECT-TYPE The type of the optical amplifier targeted for PM retrieval. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.1 | OaType | not-accessible | current |
| oaHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the amplifier targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| oaHistPMSlotIdx OBJECT-TYPE The number of the slot within which the optical amplifier targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.3 | INTEGER (1..20) | not-accessible | current |
| oaHistPMOaIdx OBJECT-TYPE The number of the amplifier port on the circuit pack targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.4 | INTEGER (1) | not-accessible | current |
| oaHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.5 | PMIntervalType | not-accessible | current |
| oaHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.6 | INTEGER (1..96) | not-accessible | current |
| oaHistPMCaseTempValue OBJECT-TYPE The optical amplifier case temperature. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.7 | INTEGER (-32768..32767) | read-only | current |
| oaHistPMCaseTempTimeStamp OBJECT-TYPE The date and time stamp of the case temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.8 | DateAndTime | read-only | current |
| oaHistPMCaseTempValidity OBJECT-TYPE Indicates the validity of the provided case temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.9 | PMValidity | read-only | current |
| oaHistPMLaser1TempValue OBJECT-TYPE The optical amplifier laser 1 temperature. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.10 | INTEGER (-32768..32767) | read-only | current |
| oaHistPMLaser1TempTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.11 | DateAndTime | read-only | current |
| oaHistPMLaser1TempValidity OBJECT-TYPE Indicates the validity of the provided laser 1 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.12 | PMValidity | read-only | current |
| oaHistPMLaser2TempValue OBJECT-TYPE The optical amplifier laser 2 temperature. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.13 | INTEGER (-32768..32767) | read-only | current |
| oaHistPMLaser2TempTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.14 | DateAndTime | read-only | current |
| oaHistPMLaser2TempValidity OBJECT-TYPE Indicates the validity of the provided laser 2 temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.15 | PMValidity | read-only | current |
| oaHistPMOPRValue OBJECT-TYPE The optical power received on the input of the amplifer. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.16 | FixedX10 | read-only | current |
| oaHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.17 | DateAndTime | read-only | current |
| oaHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.18 | PMValidity | read-only | current |
| oaHistPMSSIOPRValue OBJECT-TYPE The optical power received on the input of the second stage of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.19 | FixedX10 | read-only | current |
| oaHistPMSSIOPRTimeStamp OBJECT-TYPE The date and time stamp of the second stage input optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.20 | DateAndTime | read-only | current |
| oaHistPMSSIOPRValidity OBJECT-TYPE Indicates the validity of the provided second stage input optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.21 | PMValidity | read-only | current |
| oaHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.22 | FixedX10 | read-only | current |
| oaHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.23 | DateAndTime | read-only | current |
| oaHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.24 | PMValidity | read-only | current |
| oaHistPMMSInsLossValue OBJECT-TYPE The mid-stage insertion loss. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.25 | FixedX10 | read-only | current |
| oaHistPMMSInsLossTimeStamp OBJECT-TYPE The date and time stamp of the mid-stage insertion loss value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.26 | DateAndTime | read-only | current |
| oaHistPMMSInsLossValidity OBJECT-TYPE Indicates the validity of the provided mid-stage insertion loss value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.27 | PMValidity | read-only | current |
| oaHistPMEffectiveGainValue OBJECT-TYPE The effective gain of the optical amplifier. This reading is compensated for amplified spontaneous emissions. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.28 | FixedX10 | read-only | current |
| oaHistPMEffectiveGainTimeStamp OBJECT-TYPE The date and time stamp of the effective gain value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.29 | DateAndTime | read-only | current |
| oaHistPMEffectiveGainValidity OBJECT-TYPE Indicates the validity of the provided effective gain value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.30 | PMValidity | read-only | current |
| oaHistPMFSOOPTValue OBJECT-TYPE The optical power transmitted at the output of the first stage of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.31 | FixedX10 | read-only | current |
| oaHistPMFSOOPTTimeStamp OBJECT-TYPE The date and time stamp of the first stage output optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.32 | DateAndTime | read-only | current |
| oaHistPMFSOOPTValidity OBJECT-TYPE Indicates the validity of the provided first stage output optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.33 | PMValidity | read-only | current |
| oaHistPMLaser1CurrentValue OBJECT-TYPE The optical amplifier laser 1 current. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.34 | FixedX10 | read-only | current |
| oaHistPMLaser1CurrentTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 current value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.35 | DateAndTime | read-only | current |
| oaHistPMLaser1CurrentValidity OBJECT-TYPE Indicates the validity of the provided laser 1 current value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.36 | PMValidity | read-only | current |
| oaHistPMLaser2CurrentValue OBJECT-TYPE The optical amplifier laser 2 current. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.37 | FixedX10 | read-only | current |
| oaHistPMLaser2CurrentTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 current value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.38 | DateAndTime | read-only | current |
| oaHistPMLaser2CurrentValidity OBJECT-TYPE Indicates the validity of the provided laser 2 current value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.39 | PMValidity | read-only | current |
| oaHistPMLaser1PowerValue OBJECT-TYPE The optical amplifier laser 1 power. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.40 | FixedX10 | read-only | current |
| oaHistPMLaser1PowerTimeStamp OBJECT-TYPE The date and time stamp of the laser 1 power value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.41 | DateAndTime | read-only | current |
| oaHistPMLaser1PowerValidity OBJECT-TYPE Indicates the validity of the provided laser 1 power value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.42 | PMValidity | read-only | current |
| oaHistPMLaser2PowerValue OBJECT-TYPE The optical amplifier laser 2 power. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.43 | FixedX10 | read-only | current |
| oaHistPMLaser2PowerTimeStamp OBJECT-TYPE The date and time stamp of the laser 2 power value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.44 | DateAndTime | read-only | current |
| oaHistPMLaser2PowerValidity OBJECT-TYPE Indicates the validity of the provided laser 2 power value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.45 | PMValidity | read-only | current |
| oaHistPMOBRValue OBJECT-TYPE The back reflected optical power measured at the output of the second stage of the optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.46 | FixedX10 | read-only | current |
| oaHistPMOBRTimeStamp OBJECT-TYPE The date and time stamp of the optical back reflection value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.47 | DateAndTime | read-only | current |
| oaHistPMOBRValidity OBJECT-TYPE Indicates the validity of the provided optical back reflection value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.48 | PMValidity | read-only | current |
| oaHistPMVOAValue OBJECT-TYPE The variable optical attenuation of the amplifier. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.49 | FixedX10 | read-only | current |
| oaHistPMVOATimeStamp OBJECT-TYPE The date and time stamp of the variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.50 | DateAndTime | read-only | current |
| oaHistPMVOAValidity OBJECT-TYPE Indicates the validity of the provided variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.2.1.51 | PMValidity | read-only | current |
| xcvrCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the optical transceiver facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.3 | not-accessible | current | |
| xcvrCrntPMEntry OBJECT-TYPE The row entry object of the optical transceiver current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1 | not-accessible | current | |
| xcvrCrntPMTypeIdx OBJECT-TYPE The type of the optical transceiver targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.1 | XcvrType | not-accessible | current |
| xcvrCrntPMShelfIdx OBJECT-TYPE The shelf number on which the optical transceiver targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrCrntPMSlotIdx OBJECT-TYPE The slot number on which the optical transceiver targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrCrntPMIdx OBJECT-TYPE The optical transceiver port number on the circuit pack that is targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.5 | PMIntervalType | not-accessible | current |
| xcvrCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.6 | FixedX10 | read-only | current |
| xcvrCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.7 | DateAndTime | read-only | current |
| xcvrCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.8 | PMValidity | read-only | current |
| xcvrCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.9 | FixedX10 | read-only | current |
| xcvrCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.10 | DateAndTime | read-only | current |
| xcvrCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.11 | PMValidity | read-only | current |
| xcvrCrntPMTempValue OBJECT-TYPE The optical transceiver temperature. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.12 | INTEGER (-32768..32767) | read-only | current |
| xcvrCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.13 | DateAndTime | read-only | current |
| xcvrCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.14 | PMValidity | read-only | current |
| xcvrCrntPMSupplyVoltageValue OBJECT-TYPE The transceiver supply voltage. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.15 | FixedX10 | read-only | current |
| xcvrCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.16 | DateAndTime | read-only | current |
| xcvrCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.17 | PMValidity | read-only | current |
| xcvrCrntPMLBCValue OBJECT-TYPE The transceiver laser bias current. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.18 | INTEGER (-32768..32767) | read-only | current |
| xcvrCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.19 | DateAndTime | read-only | current |
| xcvrCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.20 | PMValidity | read-only | current |
| xcvrCrntPMCVSValue OBJECT-TYPE The count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.21 | Unsigned32 | read-write | current |
| xcvrCrntPMCVSTimeStamp OBJECT-TYPE The date and time stamp of the section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.22 | DateAndTime | read-only | current |
| xcvrCrntPMCVSValidity OBJECT-TYPE Indicates the validity of the provided section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.23 | PMValidity | read-only | current |
| xcvrCrntPMESSValue OBJECT-TYPE The count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.24 | Unsigned32 | read-write | current |
| xcvrCrntPMESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.25 | DateAndTime | read-only | current |
| xcvrCrntPMESSValidity OBJECT-TYPE Indicates the validity of the provided section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.26 | PMValidity | read-only | current |
| xcvrCrntPMSESSValue OBJECT-TYPE The count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.27 | Unsigned32 | read-write | current |
| xcvrCrntPMSESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.28 | DateAndTime | read-only | current |
| xcvrCrntPMSESSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.29 | PMValidity | read-only | current |
| xcvrCrntPMSEFSSValue OBJECT-TYPE The count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.30 | Unsigned32 | read-write | current |
| xcvrCrntPMSEFSSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.31 | DateAndTime | read-only | current |
| xcvrCrntPMSEFSSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.32 | PMValidity | read-only | current |
| xcvrCrntPMRSEBValue OBJECT-TYPE The count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.33 | Unsigned32 | read-write | current |
| xcvrCrntPMRSEBTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.34 | DateAndTime | read-only | current |
| xcvrCrntPMRSEBValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.35 | PMValidity | read-only | current |
| xcvrCrntPMRSBBEValue OBJECT-TYPE The count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.36 | Unsigned32 | read-write | current |
| xcvrCrntPMRSBBETimeStamp OBJECT-TYPE The date and time stamp of the regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.37 | DateAndTime | read-only | current |
| xcvrCrntPMRSBBEValidity OBJECT-TYPE Indicates the validity of the provided regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.38 | PMValidity | read-only | current |
| xcvrCrntPMRSESValue OBJECT-TYPE The count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.39 | Unsigned32 | read-write | current |
| xcvrCrntPMRSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.40 | DateAndTime | read-only | current |
| xcvrCrntPMRSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.41 | PMValidity | read-only | current |
| xcvrCrntPMRSSESValue OBJECT-TYPE The count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.42 | Unsigned32 | read-write | current |
| xcvrCrntPMRSSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.43 | DateAndTime | read-only | current |
| xcvrCrntPMRSSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.44 | PMValidity | read-only | current |
| xcvrCrntPMRSOFSValue OBJECT-TYPE The count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.45 | Unsigned32 | read-write | current |
| xcvrCrntPMRSOFSTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.46 | DateAndTime | read-only | current |
| xcvrCrntPMRSOFSValidity OBJECT-TYPE Indicates the validity of the provided regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.47 | PMValidity | read-only | current |
| xcvrCrntPMCVValue OBJECT-TYPE The count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.48 | Unsigned32 | read-write | current |
| xcvrCrntPMCVTimeStamp OBJECT-TYPE The date and time stamp of the coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.49 | DateAndTime | read-only | current |
| xcvrCrntPMCVValidity OBJECT-TYPE Indicates the validity of the provided coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.50 | PMValidity | read-only | current |
| xcvrCrntPMESValue OBJECT-TYPE The count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.51 | Unsigned32 | read-write | current |
| xcvrCrntPMESTimeStamp OBJECT-TYPE The date and time stamp of the errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.52 | DateAndTime | read-only | current |
| xcvrCrntPMESValidity OBJECT-TYPE Indicates the validity of the provided errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.53 | PMValidity | read-only | current |
| xcvrCrntPMSESValue OBJECT-TYPE The count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.54 | Unsigned32 | read-write | current |
| xcvrCrntPMSESTimeStamp OBJECT-TYPE The date and time stamp of the severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.55 | DateAndTime | read-only | current |
| xcvrCrntPMSESValidity OBJECT-TYPE Indicates the validity of the provided severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.56 | PMValidity | read-only | current |
| xcvrCrntPMINVBLKValue OBJECT-TYPE The count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.57 | Unsigned32 | read-write | current |
| xcvrCrntPMINVBLKTimeStamp OBJECT-TYPE The date and time stamp of the invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.58 | DateAndTime | read-only | current |
| xcvrCrntPMINVBLKValidity OBJECT-TYPE Indicates the validity of the provided invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.59 | PMValidity | read-only | current |
| xcvrCrntPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.3.1.60 | Unsigned32 | read-write | current |
| xcvrCrntPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.61 | DateAndTime | read-only | current |
| xcvrCrntPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.62 | PMValidity | read-only | current |
| xcvrCrntPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.3.1.63 | Unsigned32 | read-write | current |
| xcvrCrntPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.64 | DateAndTime | read-only | current |
| xcvrCrntPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.65 | PMValidity | read-only | current |
| xcvrCrntPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.3.1.66 | Unsigned32 | read-write | current |
| xcvrCrntPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.67 | DateAndTime | read-only | current |
| xcvrCrntPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.68 | PMValidity | read-only | current |
| xcvrCrntPMTBYCRXValue OBJECT-TYPE The total number of bytes of data (including those in bad frames) received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.69 | Unsigned64 | read-only | current |
| xcvrCrntPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the received bytes count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.70 | DateAndTime | read-only | current |
| xcvrCrntPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided received bytes count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.71 | PMValidity | read-only | current |
| xcvrCrntPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.72 | InitializeCmd | read-write | current |
| xcvrCrntPMTFRCRXValue OBJECT-TYPE The total number of received frames (incl. bad frames, broadcast frames, and multicast frames received). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.73 | Unsigned64 | read-only | current |
| xcvrCrntPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received frames count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.74 | DateAndTime | read-only | current |
| xcvrCrntPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided received frames count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.75 | PMValidity | read-only | current |
| xcvrCrntPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMTFRCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.76 | InitializeCmd | read-write | current |
| xcvrCrntPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.77 | Unsigned64 | read-only | current |
| xcvrCrntPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.78 | DateAndTime | read-only | current |
| xcvrCrntPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.79 | PMValidity | read-only | current |
| xcvrCrntPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.80 | InitializeCmd | read-write | current |
| xcvrCrntPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.81 | Unsigned64 | read-only | current |
| xcvrCrntPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.82 | DateAndTime | read-only | current |
| xcvrCrntPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.83 | PMValidity | read-only | current |
| xcvrCrntPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.84 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.85 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.86 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.87 | PMValidity | read-only | current |
| xcvrCrntPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.88 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.89 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.90 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.91 | PMValidity | read-only | current |
| xcvrCrntPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.92 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.93 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.94 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.95 | PMValidity | read-only | current |
| xcvrCrntPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.96 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.97 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.98 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.99 | PMValidity | read-only | current |
| xcvrCrntPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.100 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.101 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.102 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.103 | PMValidity | read-only | current |
| xcvrCrntPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.104 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.105 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.106 | DateAndTime | read-only | current |
| xcvrCrntPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.107 | PMValidity | read-only | current |
| xcvrCrntPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.108 | InitializeCmd | read-write | current |
| xcvrCrntPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.109 | Unsigned64 | read-only | current |
| xcvrCrntPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.110 | DateAndTime | read-only | current |
| xcvrCrntPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.111 | PMValidity | read-only | current |
| xcvrCrntPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.112 | InitializeCmd | read-write | current |
| xcvrCrntPMFCSEValue OBJECT-TYPE The count of packets that had a valid length but had either a Frame Check Sequence (FCS) or a bad FCS with a non-integral number of octets (Alignment Error) . This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.113 | Unsigned32 | read-write | current |
| xcvrCrntPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the count of packets with bad FCS or alignment error. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.114 | DateAndTime | read-only | current |
| xcvrCrntPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided count of packets with bad FCS or alignment error. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.115 | PMValidity | read-only | current |
| xcvrCrntPMFRDRValue OBJECT-TYPE The total number of dropped frames due to lack of resources or otherwise. Note that this number is not necessarily the number of frames dropped; it is just the number of times that it could be detected. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.116 | Unsigned32 | read-write | current |
| xcvrCrntPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the count of dropped packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.117 | DateAndTime | read-only | current |
| xcvrCrntPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided count of dropped packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.118 | PMValidity | read-only | current |
| xcvrCrntPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.119 | Unsigned32 | read-write | current |
| xcvrCrntPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.120 | DateAndTime | read-only | current |
| xcvrCrntPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.121 | PMValidity | read-only | current |
| xcvrCrntPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.122 | Unsigned32 | read-write | current |
| xcvrCrntPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.123 | DateAndTime | read-only | current |
| xcvrCrntPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.124 | PMValidity | read-only | current |
| xcvrCrntPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.125 | Unsigned32 | read-write | current |
| xcvrCrntPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.126 | DateAndTime | read-only | current |
| xcvrCrntPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.127 | PMValidity | read-only | current |
| xcvrCrntPMJABRValue OBJECT-TYPE The total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.128 | Unsigned32 | read-write | current |
| xcvrCrntPMJABRTimeStamp OBJECT-TYPE The date and time stamp of the count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.129 | DateAndTime | read-only | current |
| xcvrCrntPMJABRValidity OBJECT-TYPE Indicates the validity of the provided count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.130 | PMValidity | read-only | current |
| xcvrCrntPMOTUEBValue OBJECT-TYPE The count of OTN digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.131 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.132 | DateAndTime | read-only | current |
| xcvrCrntPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.133 | PMValidity | read-only | current |
| xcvrCrntPMOTUBBEValue OBJECT-TYPE The count of OTN digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.134 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.135 | DateAndTime | read-only | current |
| xcvrCrntPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.136 | PMValidity | read-only | current |
| xcvrCrntPMOTUESValue OBJECT-TYPE The count of errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.137 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.138 | DateAndTime | read-only | current |
| xcvrCrntPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.139 | PMValidity | read-only | current |
| xcvrCrntPMOTUSESValue OBJECT-TYPE The count of severely errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.140 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.141 | DateAndTime | read-only | current |
| xcvrCrntPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.142 | PMValidity | read-only | current |
| xcvrCrntPMOTUOFSValue OBJECT-TYPE The count of Out-Of-Frame seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.143 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer Out-Of-Frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.144 | DateAndTime | read-only | current |
| xcvrCrntPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer Out-of-Frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.145 | PMValidity | read-only | current |
| xcvrCrntPMSupplyVoltage2Value OBJECT-TYPE A second supply voltage value on the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.146 | FixedX10 | read-only | current |
| xcvrCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.147 | DateAndTime | read-only | current |
| xcvrCrntPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.148 | PMValidity | read-only | current |
| xcvrCrntPMCVSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMCVSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.149 | InitializeCmd | read-write | current |
| xcvrCrntPMESSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.150 | InitializeCmd | read-write | current |
| xcvrCrntPMSESSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.151 | InitializeCmd | read-write | current |
| xcvrCrntPMSEFSSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSEFSSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.152 | InitializeCmd | read-write | current |
| xcvrCrntPMRSEBInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.153 | InitializeCmd | read-write | current |
| xcvrCrntPMRSBBEInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.154 | InitializeCmd | read-write | current |
| xcvrCrntPMRSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.155 | InitializeCmd | read-write | current |
| xcvrCrntPMRSSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.156 | InitializeCmd | read-write | current |
| xcvrCrntPMRSOFSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.157 | InitializeCmd | read-write | current |
| xcvrCrntPMCVInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.158 | InitializeCmd | read-write | current |
| xcvrCrntPMESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.159 | InitializeCmd | read-write | current |
| xcvrCrntPMSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.160 | InitializeCmd | read-write | current |
| xcvrCrntPMINVBLKInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMINVBLKValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.161 | InitializeCmd | read-write | current |
| xcvrCrntPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.162 | InitializeCmd | read-write | current |
| xcvrCrntPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.163 | InitializeCmd | read-write | current |
| xcvrCrntPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.164 | InitializeCmd | read-write | current |
| xcvrCrntPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.165 | InitializeCmd | read-write | current |
| xcvrCrntPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.166 | InitializeCmd | read-write | current |
| xcvrCrntPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.167 | InitializeCmd | read-write | current |
| xcvrCrntPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.168 | InitializeCmd | read-write | current |
| xcvrCrntPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.169 | InitializeCmd | read-write | current |
| xcvrCrntPMJABRInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMJABRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.170 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.171 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.172 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.173 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.174 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.175 | InitializeCmd | read-write | current |
| xcvrCrntPMUASSValue OBJECT-TYPE The count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.176 | Unsigned32 | read-write | current |
| xcvrCrntPMUASSTimeStamp OBJECT-TYPE The date and time stamp of the section layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.177 | DateAndTime | read-only | current |
| xcvrCrntPMUASSValidity OBJECT-TYPE Indicates the validity of the provided section layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.178 | PMValidity | read-only | current |
| xcvrCrntPMUASSInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMUASSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.179 | InitializeCmd | read-write | current |
| xcvrCrntPMRSUASValue OBJECT-TYPE The count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.180 | Unsigned32 | read-write | current |
| xcvrCrntPMRSUASTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.181 | DateAndTime | read-only | current |
| xcvrCrntPMRSUASValidity OBJECT-TYPE Indicates the validity of the provided regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.182 | PMValidity | read-only | current |
| xcvrCrntPMRSUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMRSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.183 | InitializeCmd | read-write | current |
| xcvrCrntPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.184 | Unsigned32 | read-write | current |
| xcvrCrntPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.185 | DateAndTime | read-only | current |
| xcvrCrntPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.186 | PMValidity | read-only | current |
| xcvrCrntPMUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.187 | InitializeCmd | read-write | current |
| xcvrCrntPMOTUUASValue OBJECT-TYPE The count of unavailable seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.188 | Unsigned32 | read-write | current |
| xcvrCrntPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.189 | DateAndTime | read-only | current |
| xcvrCrntPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.190 | PMValidity | read-only | current |
| xcvrCrntPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.191 | InitializeCmd | read-write | current |
| xcvrCrntPMOTNBERValue OBJECT-TYPE The instantaneous BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.192 | DisplayString | read-only | current |
| xcvrCrntPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.193 | DateAndTime | read-only | current |
| xcvrCrntPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.194 | PMValidity | read-only | current |
| xcvrCrntPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.195 | InitializeCmd | read-write | current |
| xcvrCrntPMOTNAVGBERValue OBJECT-TYPE The average/interval BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.196 | DisplayString | read-only | current |
| xcvrCrntPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the average/interval BER. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.197 | DateAndTime | read-only | current |
| xcvrCrntPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided average/interval BER. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.198 | PMValidity | read-only | current |
| xcvrCrntPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.199 | InitializeCmd | read-write | current |
| xcvrCrntPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.3.1.200 | Unsigned64 | read-only | current |
| xcvrCrntPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.201 | DateAndTime | read-only | current |
| xcvrCrntPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.202 | PMValidity | read-only | current |
| xcvrCrntPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.203 | InitializeCmd | read-write | current |
| xcvrCrntPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.3.1.204 | Unsigned64 | read-only | current |
| xcvrCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.205 | DateAndTime | read-only | current |
| xcvrCrntPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.206 | PMValidity | read-only | current |
| xcvrCrntPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.207 | InitializeCmd | read-write | current |
| xcvrCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.208 | FixedX10 | read-only | current |
| xcvrCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.209 | DateAndTime | read-only | current |
| xcvrCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.210 | PMValidity | read-only | current |
| xcvrCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.211 | InitializeCmd | read-write | current |
| xcvrCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.212 | FixedX10 | read-only | current |
| xcvrCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.213 | DateAndTime | read-only | current |
| xcvrCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.214 | PMValidity | read-only | current |
| xcvrCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.215 | InitializeCmd | read-write | current |
| xcvrCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.216 | FixedX10 | read-only | current |
| xcvrCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.217 | DateAndTime | read-only | current |
| xcvrCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.218 | PMValidity | read-only | current |
| xcvrCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.219 | InitializeCmd | read-write | current |
| xcvrCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.220 | FixedX10 | read-only | current |
| xcvrCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.221 | DateAndTime | read-only | current |
| xcvrCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.222 | PMValidity | read-only | current |
| xcvrCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.223 | InitializeCmd | read-write | current |
| xcvrCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.224 | FixedX10 | read-only | current |
| xcvrCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.225 | DateAndTime | read-only | current |
| xcvrCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.226 | PMValidity | read-only | current |
| xcvrCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.227 | InitializeCmd | read-write | current |
| xcvrCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.228 | FixedX10 | read-only | current |
| xcvrCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.229 | DateAndTime | read-only | current |
| xcvrCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.230 | PMValidity | read-only | current |
| xcvrCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the xcvrCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.3.1.231 | InitializeCmd | read-write | current |
| xcvrHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the optical transceiver facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.4 | not-accessible | current | |
| xcvrHistPMEntry OBJECT-TYPE The row entry object of the optical transceiver historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1 | not-accessible | current | |
| xcvrHistPMTypeIdx OBJECT-TYPE The type of the optical transceiver targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.1 | XcvrType | not-accessible | current |
| xcvrHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the optical transceiver targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrHistPMSlotIdx OBJECT-TYPE The number of the slot within which the optical transceiver targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrHistPMIdx OBJECT-TYPE The number of the transceiver port targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.5 | PMIntervalType | not-accessible | current |
| xcvrHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.6 | INTEGER (1..96) | not-accessible | current |
| xcvrHistPMOPRValue OBJECT-TYPE The optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.7 | FixedX10 | read-only | current |
| xcvrHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.8 | DateAndTime | read-only | current |
| xcvrHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.9 | PMValidity | read-only | current |
| xcvrHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.10 | FixedX10 | read-only | current |
| xcvrHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.11 | DateAndTime | read-only | current |
| xcvrHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.12 | PMValidity | read-only | current |
| xcvrHistPMTempValue OBJECT-TYPE The optical transceiver temperature. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.13 | INTEGER (-32768..32767) | read-only | current |
| xcvrHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.14 | DateAndTime | read-only | current |
| xcvrHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.15 | PMValidity | read-only | current |
| xcvrHistPMSupplyVoltageValue OBJECT-TYPE The transceiver supply voltage. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.16 | FixedX10 | read-only | current |
| xcvrHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.17 | DateAndTime | read-only | current |
| xcvrHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.18 | PMValidity | read-only | current |
| xcvrHistPMLBCValue OBJECT-TYPE The transceiver laser bias current. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.19 | INTEGER (-32768..32767) | read-only | current |
| xcvrHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.20 | DateAndTime | read-only | current |
| xcvrHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.21 | PMValidity | read-only | current |
| xcvrHistPMCVSValue OBJECT-TYPE The count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.22 | Unsigned32 | read-write | current |
| xcvrHistPMCVSTimeStamp OBJECT-TYPE The date and time stamp of the section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.23 | DateAndTime | read-only | current |
| xcvrHistPMCVSValidity OBJECT-TYPE Indicates the validity of the provided section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.24 | PMValidity | read-only | current |
| xcvrHistPMESSValue OBJECT-TYPE The count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.25 | Unsigned32 | read-write | current |
| xcvrHistPMESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.26 | DateAndTime | read-only | current |
| xcvrHistPMESSValidity OBJECT-TYPE Indicates the validity of the provided section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.27 | PMValidity | read-only | current |
| xcvrHistPMSESSValue OBJECT-TYPE The count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.28 | Unsigned32 | read-write | current |
| xcvrHistPMSESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.29 | DateAndTime | read-only | current |
| xcvrHistPMSESSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.30 | PMValidity | read-only | current |
| xcvrHistPMSEFSSValue OBJECT-TYPE The count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.31 | Unsigned32 | read-write | current |
| xcvrHistPMSEFSSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.32 | DateAndTime | read-only | current |
| xcvrHistPMSEFSSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.33 | PMValidity | read-only | current |
| xcvrHistPMRSEBValue OBJECT-TYPE The count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.34 | Unsigned32 | read-write | current |
| xcvrHistPMRSEBTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.35 | DateAndTime | read-only | current |
| xcvrHistPMRSEBValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.36 | PMValidity | read-only | current |
| xcvrHistPMRSBBEValue OBJECT-TYPE The count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.37 | Unsigned32 | read-write | current |
| xcvrHistPMRSBBETimeStamp OBJECT-TYPE The date and time stamp of the regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.38 | DateAndTime | read-only | current |
| xcvrHistPMRSBBEValidity OBJECT-TYPE Indicates the validity of the provided regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.39 | PMValidity | read-only | current |
| xcvrHistPMRSESValue OBJECT-TYPE The count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.40 | Unsigned32 | read-write | current |
| xcvrHistPMRSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.41 | DateAndTime | read-only | current |
| xcvrHistPMRSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.42 | PMValidity | read-only | current |
| xcvrHistPMRSSESValue OBJECT-TYPE The count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.43 | Unsigned32 | read-write | current |
| xcvrHistPMRSSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.44 | DateAndTime | read-only | current |
| xcvrHistPMRSSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.45 | PMValidity | read-only | current |
| xcvrHistPMRSOFSValue OBJECT-TYPE The count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.46 | Unsigned32 | read-write | current |
| xcvrHistPMRSOFSTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.47 | DateAndTime | read-only | current |
| xcvrHistPMRSOFSValidity OBJECT-TYPE Indicates the validity of the provided regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.48 | PMValidity | read-only | current |
| xcvrHistPMCVValue OBJECT-TYPE The count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.49 | Unsigned32 | read-write | current |
| xcvrHistPMCVTimeStamp OBJECT-TYPE The date and time stamp of the coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.50 | DateAndTime | read-only | current |
| xcvrHistPMCVValidity OBJECT-TYPE Indicates the validity of the provided coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.51 | PMValidity | read-only | current |
| xcvrHistPMESValue OBJECT-TYPE The count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.52 | Unsigned32 | read-write | current |
| xcvrHistPMESTimeStamp OBJECT-TYPE The date and time stamp of the errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.53 | DateAndTime | read-only | current |
| xcvrHistPMESValidity OBJECT-TYPE Indicates the validity of the provided errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.54 | PMValidity | read-only | current |
| xcvrHistPMSESValue OBJECT-TYPE The count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.55 | Unsigned32 | read-write | current |
| xcvrHistPMSESTimeStamp OBJECT-TYPE The date and time stamp of the severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.56 | DateAndTime | read-only | current |
| xcvrHistPMSESValidity OBJECT-TYPE Indicates the validity of the provided severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.57 | PMValidity | read-only | current |
| xcvrHistPMINVBLKValue OBJECT-TYPE The count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.58 | Unsigned32 | read-write | current |
| xcvrHistPMINVBLKTimeStamp OBJECT-TYPE The date and time stamp of the invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.59 | DateAndTime | read-only | current |
| xcvrHistPMINVBLKValidity OBJECT-TYPE Indicates the validity of the provided invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.60 | PMValidity | read-only | current |
| xcvrHistPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.4.1.61 | Unsigned32 | read-write | current |
| xcvrHistPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.62 | DateAndTime | read-only | current |
| xcvrHistPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.63 | PMValidity | read-only | current |
| xcvrHistPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.4.1.64 | Unsigned32 | read-write | current |
| xcvrHistPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.65 | DateAndTime | read-only | current |
| xcvrHistPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.66 | PMValidity | read-only | current |
| xcvrHistPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.4.1.67 | Unsigned32 | read-write | current |
| xcvrHistPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.68 | DateAndTime | read-only | current |
| xcvrHistPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.69 | PMValidity | read-only | current |
| xcvrHistPMTBYCRXValue OBJECT-TYPE The total number of bytes of data (including those in bad frames) received (excluding framing bits but including FCS bytes). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.70 | Unsigned64 | read-only | current |
| xcvrHistPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the received bytes count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.71 | DateAndTime | read-only | current |
| xcvrHistPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided received bytes count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.72 | PMValidity | read-only | current |
| xcvrHistPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.73 | InitializeCmd | read-write | current |
| xcvrHistPMTFRCRXValue OBJECT-TYPE The total number of received frames (incl. bad frames, broadcast frames, and multicast frames received). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.74 | Unsigned64 | read-only | current |
| xcvrHistPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the received frames count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.75 | DateAndTime | read-only | current |
| xcvrHistPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided received frames count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.76 | PMValidity | read-only | current |
| xcvrHistPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMTFRCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.77 | InitializeCmd | read-write | current |
| xcvrHistPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.78 | Unsigned64 | read-only | current |
| xcvrHistPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.79 | DateAndTime | read-only | current |
| xcvrHistPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.80 | PMValidity | read-only | current |
| xcvrHistPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.81 | InitializeCmd | read-write | current |
| xcvrHistPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.82 | Unsigned64 | read-only | current |
| xcvrHistPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.83 | DateAndTime | read-only | current |
| xcvrHistPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.84 | PMValidity | read-only | current |
| xcvrHistPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.85 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.86 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.87 | DateAndTime | read-only | current |
| xcvrHistPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.88 | PMValidity | read-only | current |
| xcvrHistPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.89 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.90 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.91 | DateAndTime | read-only | current |
| xcvrHistPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.92 | PMValidity | read-only | current |
| xcvrHistPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.93 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.94 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.95 | DateAndTime | read-only | current |
| xcvrHistPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.96 | PMValidity | read-only | current |
| xcvrHistPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.97 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.98 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.99 | DateAndTime | read-only | current |
| xcvrHistPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.100 | PMValidity | read-only | current |
| xcvrHistPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.101 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.102 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.103 | DateAndTime | read-only | current |
| xcvrHistPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.104 | PMValidity | read-only | current |
| xcvrHistPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.105 | InitializeCmd | read-write | current |
| xcvrHistPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.106 | Unsigned64 | read-only | current |
| xcvrHistPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.107 | DateAndTime | read-only | current |
| xcvrHistPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.108 | PMValidity | read-only | current |
| xcvrHistPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.109 | InitializeCmd | read-write | current |
| xcvrHistPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.110 | Unsigned64 | read-only | current |
| xcvrHistPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.111 | DateAndTime | read-only | current |
| xcvrHistPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.112 | PMValidity | read-only | current |
| xcvrHistPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.113 | InitializeCmd | read-write | current |
| xcvrHistPMFCSEValue OBJECT-TYPE The count of packets that had a valid length but had either a Frame Check Sequence (FCS) or a bad FCS with a non-integral number of octets (Alignment Error) . This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.114 | Unsigned32 | read-write | current |
| xcvrHistPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the count of packets with bad FCS or alignment error. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.115 | DateAndTime | read-only | current |
| xcvrHistPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided count of packets with bad FCS or alignment error. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.116 | PMValidity | read-only | current |
| xcvrHistPMFRDRValue OBJECT-TYPE The total number of dropped frames due to lack of resources or otherwise. Note that this number is not necessarily the number of frames dropped; it is just the number of times that it could be detected. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.117 | Unsigned32 | read-write | current |
| xcvrHistPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the count of dropped packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.118 | DateAndTime | read-only | current |
| xcvrHistPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided count of dropped packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.119 | PMValidity | read-only | current |
| xcvrHistPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.120 | Unsigned32 | read-write | current |
| xcvrHistPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.121 | DateAndTime | read-only | current |
| xcvrHistPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.122 | PMValidity | read-only | current |
| xcvrHistPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.123 | Unsigned32 | read-write | current |
| xcvrHistPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.124 | DateAndTime | read-only | current |
| xcvrHistPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.125 | PMValidity | read-only | current |
| xcvrHistPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.126 | Unsigned32 | read-write | current |
| xcvrHistPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.127 | DateAndTime | read-only | current |
| xcvrHistPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.128 | PMValidity | read-only | current |
| xcvrHistPMJABRValue OBJECT-TYPE The total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.129 | Unsigned32 | read-write | current |
| xcvrHistPMJABRTimeStamp OBJECT-TYPE The date and time stamp of the count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.130 | DateAndTime | read-only | current |
| xcvrHistPMJABRValidity OBJECT-TYPE Indicates the validity of the provided count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.131 | PMValidity | read-only | current |
| xcvrHistPMOTUEBValue OBJECT-TYPE The count of OTN digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.132 | Unsigned32 | read-write | current |
| xcvrHistPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.133 | DateAndTime | read-only | current |
| xcvrHistPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.134 | PMValidity | read-only | current |
| xcvrHistPMOTUBBEValue OBJECT-TYPE The count of OTN digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.135 | Unsigned32 | read-write | current |
| xcvrHistPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.136 | DateAndTime | read-only | current |
| xcvrHistPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.137 | PMValidity | read-only | current |
| xcvrHistPMOTUESValue OBJECT-TYPE The count of errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.138 | Unsigned32 | read-write | current |
| xcvrHistPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.139 | DateAndTime | read-only | current |
| xcvrHistPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.140 | PMValidity | read-only | current |
| xcvrHistPMOTUSESValue OBJECT-TYPE The count of severely errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.141 | Unsigned32 | read-write | current |
| xcvrHistPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.142 | DateAndTime | read-only | current |
| xcvrHistPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.143 | PMValidity | read-only | current |
| xcvrHistPMOTUOFSValue OBJECT-TYPE The count of Out-Of-Frame seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.144 | Unsigned32 | read-write | current |
| xcvrHistPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer Out-Of-Frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.145 | DateAndTime | read-only | current |
| xcvrHistPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer Out-of-Frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.146 | PMValidity | read-only | current |
| xcvrHistPMSupplyVoltage2Value OBJECT-TYPE A second supply voltage value on the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.147 | FixedX10 | read-only | current |
| xcvrHistPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.148 | DateAndTime | read-only | current |
| xcvrHistPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.149 | PMValidity | read-only | current |
| xcvrHistPMCVSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMCVSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.150 | InitializeCmd | read-write | current |
| xcvrHistPMESSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.151 | InitializeCmd | read-write | current |
| xcvrHistPMSESSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.152 | InitializeCmd | read-write | current |
| xcvrHistPMSEFSSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSEFSSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.153 | InitializeCmd | read-write | current |
| xcvrHistPMRSEBInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.154 | InitializeCmd | read-write | current |
| xcvrHistPMRSBBEInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.155 | InitializeCmd | read-write | current |
| xcvrHistPMRSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.156 | InitializeCmd | read-write | current |
| xcvrHistPMRSSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.157 | InitializeCmd | read-write | current |
| xcvrHistPMRSOFSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.158 | InitializeCmd | read-write | current |
| xcvrHistPMCVInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.159 | InitializeCmd | read-write | current |
| xcvrHistPMESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.160 | InitializeCmd | read-write | current |
| xcvrHistPMSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.161 | InitializeCmd | read-write | current |
| xcvrHistPMINVBLKInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMINVBLKValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.162 | InitializeCmd | read-write | current |
| xcvrHistPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.163 | InitializeCmd | read-write | current |
| xcvrHistPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.164 | InitializeCmd | read-write | current |
| xcvrHistPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.165 | InitializeCmd | read-write | current |
| xcvrHistPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.166 | InitializeCmd | read-write | current |
| xcvrHistPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.167 | InitializeCmd | read-write | current |
| xcvrHistPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.168 | InitializeCmd | read-write | current |
| xcvrHistPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.169 | InitializeCmd | read-write | current |
| xcvrHistPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.170 | InitializeCmd | read-write | current |
| xcvrHistPMJABRInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMJABRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.171 | InitializeCmd | read-write | current |
| xcvrHistPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.172 | InitializeCmd | read-write | current |
| xcvrHistPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.173 | InitializeCmd | read-write | current |
| xcvrHistPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.174 | InitializeCmd | read-write | current |
| xcvrHistPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.175 | InitializeCmd | read-write | current |
| xcvrHistPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.176 | InitializeCmd | read-write | current |
| xcvrHistPMUASSValue OBJECT-TYPE The count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.177 | Unsigned32 | read-write | current |
| xcvrHistPMUASSTimeStamp OBJECT-TYPE The date and time stamp of the section layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.178 | DateAndTime | read-only | current |
| xcvrHistPMUASSValidity OBJECT-TYPE Indicates the validity of the provided section layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.179 | PMValidity | read-only | current |
| xcvrHistPMUASSInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMUASSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.180 | InitializeCmd | read-write | current |
| xcvrHistPMRSUASValue OBJECT-TYPE The count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.181 | Unsigned32 | read-write | current |
| xcvrHistPMRSUASTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.182 | DateAndTime | read-only | current |
| xcvrHistPMRSUASValidity OBJECT-TYPE Indicates the validity of the provided regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.183 | PMValidity | read-only | current |
| xcvrHistPMRSUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMRSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.184 | InitializeCmd | read-write | current |
| xcvrHistPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.185 | Unsigned32 | read-write | current |
| xcvrHistPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.186 | DateAndTime | read-only | current |
| xcvrHistPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.187 | PMValidity | read-only | current |
| xcvrHistPMUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.188 | InitializeCmd | read-write | current |
| xcvrHistPMOTUUASValue OBJECT-TYPE The count of unavailable seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.189 | Unsigned32 | read-write | current |
| xcvrHistPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTN digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.190 | DateAndTime | read-only | current |
| xcvrHistPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTN digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.191 | PMValidity | read-only | current |
| xcvrHistPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.192 | InitializeCmd | read-write | current |
| xcvrHistPMOTNBERValue OBJECT-TYPE The instantaneous BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.193 | DisplayString | read-only | current |
| xcvrHistPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.194 | DateAndTime | read-only | current |
| xcvrHistPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.195 | PMValidity | read-only | current |
| xcvrHistPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.196 | InitializeCmd | read-write | current |
| xcvrHistPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.197 | DisplayString | read-only | current |
| xcvrHistPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.198 | DateAndTime | read-only | current |
| xcvrHistPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.199 | PMValidity | read-only | current |
| xcvrHistPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.200 | InitializeCmd | read-write | current |
| xcvrHistPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.4.1.201 | Unsigned64 | read-only | current |
| xcvrHistPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.202 | DateAndTime | read-only | current |
| xcvrHistPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.203 | PMValidity | read-only | current |
| xcvrHistPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.204 | InitializeCmd | read-write | current |
| xcvrHistPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to transciever ports provisioned for a protocol that includes Forward Error Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.4.1.205 | Unsigned64 | read-only | current |
| xcvrHistPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.206 | DateAndTime | read-only | current |
| xcvrHistPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.207 | PMValidity | read-only | current |
| xcvrHistPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.208 | InitializeCmd | read-write | current |
| xcvrHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.209 | FixedX10 | read-only | current |
| xcvrHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.210 | DateAndTime | read-only | current |
| xcvrHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.211 | PMValidity | read-only | current |
| xcvrHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.212 | InitializeCmd | read-write | current |
| xcvrHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.213 | FixedX10 | read-only | current |
| xcvrHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.214 | DateAndTime | read-only | current |
| xcvrHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.215 | PMValidity | read-only | current |
| xcvrHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.216 | InitializeCmd | read-write | current |
| xcvrHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.217 | FixedX10 | read-only | current |
| xcvrHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.218 | DateAndTime | read-only | current |
| xcvrHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.219 | PMValidity | read-only | current |
| xcvrHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.220 | InitializeCmd | read-write | current |
| xcvrHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.221 | FixedX10 | read-only | current |
| xcvrHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.222 | DateAndTime | read-only | current |
| xcvrHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.223 | PMValidity | read-only | current |
| xcvrHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.224 | InitializeCmd | read-write | current |
| xcvrHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.225 | FixedX10 | read-only | current |
| xcvrHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.226 | DateAndTime | read-only | current |
| xcvrHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.227 | PMValidity | read-only | current |
| xcvrHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.228 | InitializeCmd | read-write | current |
| xcvrHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.229 | FixedX10 | read-only | current |
| xcvrHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.230 | DateAndTime | read-only | current |
| xcvrHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.231 | PMValidity | read-only | current |
| xcvrHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the xcvrHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.4.1.232 | InitializeCmd | read-write | current |
| xcvrPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on optical transceiver facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.5 | not-accessible | current | |
| xcvrPMThresholdEntry OBJECT-TYPE The row entry object of the optical transceiver performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual optical transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.5.1 | not-accessible | current | |
| xcvrPMThresholdTypeIdx OBJECT-TYPE The type of the optical transceiver targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.1 | XcvrType | not-accessible | current |
| xcvrPMThresholdShelfIdx OBJECT-TYPE The shelf number on which the optical transceiver targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrPMThresholdSlotIdx OBJECT-TYPE The slot number on which the optical transceiver targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrPMThresholdIdx OBJECT-TYPE The optical transceiver port number on the circuit pack that is targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.5 | PMIntervalType | not-accessible | current |
| xcvrPMThresholdCVSValue OBJECT-TYPE The threshold for the count of coding violations at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.6 | Unsigned32 | read-write | current |
| xcvrPMThresholdESSValue OBJECT-TYPE The threshold for the count of errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.7 | Unsigned32 | read-write | current |
| xcvrPMThresholdSESSValue OBJECT-TYPE The threshold fro the count of severely errored seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.8 | Unsigned32 | read-write | current |
| xcvrPMThresholdSEFSSValue OBJECT-TYPE The threshold for the count of severely errored framing seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.9 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSEBValue OBJECT-TYPE The threshold for the count of regenerator section errored blocks. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.10 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSBBEValue OBJECT-TYPE The threshold for the count of regenerator section background block errors. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.11 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSESValue OBJECT-TYPE The threshold for the count of regenerator section errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.12 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSSESValue OBJECT-TYPE The threshold for the count of regenerator section severely errored seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.13 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSOFSValue OBJECT-TYPE The threshold for the count of regenerator section out-of-frame seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.14 | Unsigned32 | read-write | current |
| xcvrPMThresholdCVValue OBJECT-TYPE The threshold for the count of coding violations. This object applies only to transciever ports provisioned for the gigabit ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.15 | Unsigned32 | read-write | current |
| xcvrPMThresholdESValue OBJECT-TYPE The threshold for the count of errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.16 | Unsigned32 | read-write | current |
| xcvrPMThresholdSESValue OBJECT-TYPE The threshold for the count of severely errored seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.17 | Unsigned32 | read-write | current |
| xcvrPMThresholdINVBLKValue OBJECT-TYPE The threshold for the count of invalid blocks. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.18 | Unsigned32 | read-write | current |
| xcvrPMThresholdUNCRCDWValue OBJECT-TYPE The threshold for the count of uncorrectable codewords. This object applies only to transciever ports provisioned for the 10 gigabit ethernet LAN with FEC protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.21 | Unsigned32 | read-write | current |
| xcvrPMThresholdFCSEValue OBJECT-TYPE The threshold for the count of FCSE packets. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.22 | Unsigned32 | read-write | current |
| xcvrPMThresholdFRDRValue OBJECT-TYPE The threshold for the count of dropped frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.23 | Unsigned32 | read-write | current |
| xcvrPMThresholdUSIZEValue OBJECT-TYPE The threshold for the count of undersized frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.24 | Unsigned32 | read-write | current |
| xcvrPMThresholdOSIZEValue OBJECT-TYPE The threshold for the count of oversized frames. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.25 | Unsigned32 | read-write | current |
| xcvrPMThresholdFRGTValue OBJECT-TYPE The threshold for the count of frame fragments. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.26 | Unsigned32 | read-write | current |
| xcvrPMThresholdJABRValue OBJECT-TYPE The threshold for the count of jabbers. This object applies only to transceiver ports provisioned for the 10 gigabit ethernet LAN protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.27 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUEBValue OBJECT-TYPE The threshold for the count of errored blocks at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.28 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUBBEValue OBJECT-TYPE The threshold for the count of background block errors at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.29 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUESValue OBJECT-TYPE The threshold for the count of errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.30 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUSESValue OBJECT-TYPE The threshold for the count of severely errored seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.31 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUOFSValue OBJECT-TYPE The threshold for the count of Out-of-Frame seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.32 | Unsigned32 | read-write | current |
| xcvrPMThresholdUASSValue OBJECT-TYPE The threshold for the count of unavailable seconds at the section layer. This object applies only to transciever ports provisioned for a SONET OC-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.33 | Unsigned32 | read-write | current |
| xcvrPMThresholdRSUASValue OBJECT-TYPE The threshold for the count of regenerator section unavailable seconds. This object applies only to transciever ports provisioned for a SDH STM-N protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.34 | Unsigned32 | read-write | current |
| xcvrPMThresholdUASValue OBJECT-TYPE The threshold for the count of unavailable seconds. This object applies only to transciever ports provisioned for an ethernet protocol or a fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.35 | Unsigned32 | read-write | current |
| xcvrPMThresholdOTUUASValue OBJECT-TYPE The threshold for the count of unavailable seconds at the OTN digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.5.1.36 | Unsigned32 | read-write | current |
| amdCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the ports of active multiplexer-demultiplexer circuit packs. | 1.3.6.1.4.1.18070.2.2.1.6.6 | not-accessible | obsolete | |
| amdCrntPMEntry OBJECT-TYPE The row entry object of the active multiplexer-demultiplexer current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.6.1 | not-accessible | obsolete | |
| amdCrntPMTypeIdx OBJECT-TYPE The specific type of active multiplexer-demultiplexer circuit pack on which the facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.1 | AmdType | not-accessible | obsolete |
| amdCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the active multiplexer-demultiplexer facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | obsolete |
| amdCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the active multiplexer-demultiplexer facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | obsolete |
| amdCrntPMLineIdx OBJECT-TYPE The number of the multiplexed wavelength line on the AMD circuit pack that is targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.4 | INTEGER (1) | not-accessible | obsolete |
| amdCrntPMPortIdx OBJECT-TYPE Identifies a specific port on the identified line of the AMD circuit pack that is targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.5 | AmdPortType | not-accessible | obsolete |
| amdCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.6 | PMIntervalType | not-accessible | obsolete |
| amdCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.7 | FixedX10 | read-only | obsolete |
| amdCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.8 | DateAndTime | read-only | obsolete |
| amdCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.9 | PMValidity | read-only | obsolete |
| amdCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.10 | FixedX10 | read-only | obsolete |
| amdCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.11 | DateAndTime | read-only | obsolete |
| amdCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.12 | PMValidity | read-only | obsolete |
| amdCrntPMVOAValue OBJECT-TYPE The variable optical attenuation of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.13 | FixedX10 | read-only | obsolete |
| amdCrntPMVOATimeStamp OBJECT-TYPE The date and time stamp of the variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.14 | DateAndTime | read-only | obsolete |
| amdCrntPMVOAValidity OBJECT-TYPE Indicates the validity of the provided variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.15 | PMValidity | read-only | obsolete |
| amdCrntPMLitChnValue OBJECT-TYPE The number of muxed channels with light on the line port. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.16 | INTEGER (0..8) | read-only | obsolete |
| amdCrntPMLitChnTimeStamp OBJECT-TYPE The date and time stamp of the number of lit channels value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.17 | DateAndTime | read-only | obsolete |
| amdCrntPMLitChnValidity OBJECT-TYPE Indicates the validity of the provided number of lit channels value. | 1.3.6.1.4.1.18070.2.2.1.6.6.1.18 | PMValidity | read-only | obsolete |
| amdHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the ports of active multiplexer-demultiplexer circuit packs. | 1.3.6.1.4.1.18070.2.2.1.6.7 | not-accessible | obsolete | |
| amdHistPMEntry OBJECT-TYPE The row entry object of the active multiplexer-demultiplexer historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.7.1 | not-accessible | obsolete | |
| amdHistPMTypeIdx OBJECT-TYPE The specific type of active multiplexer-demultiplexer circuit pack on which the facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.1 | AmdType | not-accessible | obsolete |
| amdHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the active multiplexer-demultiplexer facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | obsolete |
| amdHistPMSlotIdx OBJECT-TYPE The number of the slot within which the active multiplexer-demultiplexer facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | obsolete |
| amdHistPMLineIdx OBJECT-TYPE The number of the multiplexed wavelength line on the AMD circuit pack that is targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.4 | INTEGER (1) | not-accessible | obsolete |
| amdHistPMPortIdx OBJECT-TYPE Identifies a specific port on the identified line of the AMD circuit pack that is targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.5 | AmdPortType | not-accessible | obsolete |
| amdHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.6 | PMIntervalType | not-accessible | obsolete |
| amdHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.7 | INTEGER (1..96) | not-accessible | obsolete |
| amdHistPMOPRValue OBJECT-TYPE The optical power received on the input of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.8 | FixedX10 | read-only | obsolete |
| amdHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.9 | DateAndTime | read-only | obsolete |
| amdHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.10 | PMValidity | read-only | obsolete |
| amdHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.11 | FixedX10 | read-only | obsolete |
| amdHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.12 | DateAndTime | read-only | obsolete |
| amdHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.13 | PMValidity | read-only | obsolete |
| amdHistPMVOAValue OBJECT-TYPE The variable optical attenuation of the AMD port. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.14 | FixedX10 | read-only | obsolete |
| amdHistPMVOATimeStamp OBJECT-TYPE The date and time stamp of the variable optical attenuation value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.15 | DateAndTime | read-only | obsolete |
| amdHistPMVOAValidity OBJECT-TYPE Indicates the validity of the provided variable optical attenuation valcue. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.16 | PMValidity | read-only | obsolete |
| amdHistPMLitChnValue OBJECT-TYPE The number of muxed channels with light on the line port. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.17 | INTEGER (0..8) | read-only | obsolete |
| amdHistPMLitChnTimeStamp OBJECT-TYPE The date and time stamp of the number of lit channels value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.18 | DateAndTime | read-only | obsolete |
| amdHistPMLitChnValidity OBJECT-TYPE Indicates the validity of the provided number of lit channels value. | 1.3.6.1.4.1.18070.2.2.1.6.7.1.19 | PMValidity | read-only | obsolete |
| ocnCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the SONET OC-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.8 | not-accessible | current | |
| ocnCrntPMEntry OBJECT-TYPE The row entry object of the SONET OC-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.8.1 | not-accessible | current | |
| ocnCrntPMTypeIdx OBJECT-TYPE The type of OC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.1 | OcnType | not-accessible | current |
| ocnCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.3 | INTEGER (1..20) | not-accessible | current |
| ocnCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.4 | INTEGER (1..6) | not-accessible | current |
| ocnCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.5 | PMIntervalType | not-accessible | current |
| ocnCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.6 | FixedX10 | read-only | current |
| ocnCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.7 | DateAndTime | read-only | current |
| ocnCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.8 | PMValidity | read-only | current |
| ocnCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.9 | FixedX10 | read-only | current |
| ocnCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.10 | DateAndTime | read-only | current |
| ocnCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.11 | PMValidity | read-only | current |
| ocnCrntPMTempValue OBJECT-TYPE The temperature measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.12 | INTEGER (-32768..32767) | read-only | current |
| ocnCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.13 | DateAndTime | read-only | current |
| ocnCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.14 | PMValidity | read-only | current |
| ocnCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.15 | FixedX10 | read-only | current |
| ocnCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.16 | DateAndTime | read-only | current |
| ocnCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.17 | PMValidity | read-only | current |
| ocnCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.18 | INTEGER (-32768..32767) | read-only | current |
| ocnCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.19 | DateAndTime | read-only | current |
| ocnCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.20 | PMValidity | read-only | current |
| ocnCrntPMCVSValue OBJECT-TYPE The count of coding violations at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.21 | Unsigned32 | read-write | current |
| ocnCrntPMCVSTimeStamp OBJECT-TYPE The date and time stamp of the section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.22 | DateAndTime | read-only | current |
| ocnCrntPMCVSValidity OBJECT-TYPE Indicates the validity of the provided section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.23 | PMValidity | read-only | current |
| ocnCrntPMESSValue OBJECT-TYPE The count of errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.24 | Unsigned32 | read-write | current |
| ocnCrntPMESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.25 | DateAndTime | read-only | current |
| ocnCrntPMESSValidity OBJECT-TYPE Indicates the validity of the provided section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.26 | PMValidity | read-only | current |
| ocnCrntPMSESSValue OBJECT-TYPE The count of severely errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.27 | Unsigned32 | read-write | current |
| ocnCrntPMSESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.28 | DateAndTime | read-only | current |
| ocnCrntPMSESSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.29 | PMValidity | read-only | current |
| ocnCrntPMSEFSSValue OBJECT-TYPE The count of severely errored framing seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.30 | Unsigned32 | read-write | current |
| ocnCrntPMSEFSSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.31 | DateAndTime | read-only | current |
| ocnCrntPMSEFSSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.32 | PMValidity | read-only | current |
| ocnCrntPMSupplyVoltage2Value OBJECT-TYPE The value of the second supply voltage source measured on the OC-N facility port transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.33 | FixedX10 | read-only | current |
| ocnCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.34 | DateAndTime | read-only | current |
| ocnCrntPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.35 | PMValidity | read-only | current |
| ocnCrntPMCVLValue OBJECT-TYPE The count of coding violations at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.36 | Unsigned32 | read-write | current |
| ocnCrntPMCVLTimeStamp OBJECT-TYPE The date and time stamp of the line layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.37 | DateAndTime | read-only | current |
| ocnCrntPMCVLValidity OBJECT-TYPE Indicates the validity of the provided line layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.38 | PMValidity | read-only | current |
| ocnCrntPMESLValue OBJECT-TYPE The count of errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.39 | Unsigned32 | read-write | current |
| ocnCrntPMESLTimeStamp OBJECT-TYPE The date and time stamp of the line layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.40 | DateAndTime | read-only | current |
| ocnCrntPMESLValidity OBJECT-TYPE Indicates the validity of the provided line layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.41 | PMValidity | read-only | current |
| ocnCrntPMSESLValue OBJECT-TYPE The count of severely errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.42 | Unsigned32 | read-write | current |
| ocnCrntPMSESLTimeStamp OBJECT-TYPE The date and time stamp of the line layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.43 | DateAndTime | read-only | current |
| ocnCrntPMSESLValidity OBJECT-TYPE Indicates the validity of the provided line layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.44 | PMValidity | read-only | current |
| ocnCrntPMUASLValue OBJECT-TYPE The count of unavailable seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.45 | Unsigned32 | read-write | current |
| ocnCrntPMUASLTimeStamp OBJECT-TYPE The date and time stamp of the line layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.46 | DateAndTime | read-only | current |
| ocnCrntPMUASLValidity OBJECT-TYPE Indicates the validity of the provided line layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.47 | PMValidity | read-only | current |
| ocnCrntPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.48 | Unsigned32 | read-write | current |
| ocnCrntPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.49 | DateAndTime | read-only | current |
| ocnCrntPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.50 | PMValidity | read-only | current |
| ocnCrntPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.51 | Unsigned32 | read-write | current |
| ocnCrntPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.52 | DateAndTime | read-only | current |
| ocnCrntPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.53 | PMValidity | read-only | current |
| ocnCrntPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.54 | Unsigned32 | read-write | current |
| ocnCrntPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.55 | DateAndTime | read-only | current |
| ocnCrntPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.56 | PMValidity | read-only | current |
| ocnCrntPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.57 | Unsigned32 | read-write | current |
| ocnCrntPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.58 | DateAndTime | read-only | current |
| ocnCrntPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.59 | PMValidity | read-only | current |
| ocnCrntPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.60 | Unsigned32 | read-write | current |
| ocnCrntPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.61 | DateAndTime | read-only | current |
| ocnCrntPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.62 | PMValidity | read-only | current |
| ocnCrntPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.63 | Unsigned32 | read-write | current |
| ocnCrntPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.64 | DateAndTime | read-only | current |
| ocnCrntPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.65 | PMValidity | read-only | current |
| ocnCrntPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.66 | Unsigned32 | read-write | current |
| ocnCrntPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.67 | DateAndTime | read-only | current |
| ocnCrntPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.68 | PMValidity | read-only | current |
| ocnCrntPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.69 | Unsigned32 | read-write | current |
| ocnCrntPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.70 | DateAndTime | read-only | current |
| ocnCrntPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.71 | PMValidity | read-only | current |
| ocnCrntPMCVSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMCVSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.72 | InitializeCmd | read-write | current |
| ocnCrntPMESSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.73 | InitializeCmd | read-write | current |
| ocnCrntPMSESSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMSESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.74 | InitializeCmd | read-write | current |
| ocnCrntPMSEFSSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMSEFSSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.75 | InitializeCmd | read-write | current |
| ocnCrntPMCVLInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMCVLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.76 | InitializeCmd | read-write | current |
| ocnCrntPMESLInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMESLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.77 | InitializeCmd | read-write | current |
| ocnCrntPMSESLInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMSESLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.78 | InitializeCmd | read-write | current |
| ocnCrntPMUASLInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMUASLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.79 | InitializeCmd | read-write | current |
| ocnCrntPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.80 | InitializeCmd | read-write | current |
| ocnCrntPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.81 | InitializeCmd | read-write | current |
| ocnCrntPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.82 | InitializeCmd | read-write | current |
| ocnCrntPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.83 | InitializeCmd | read-write | current |
| ocnCrntPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.84 | InitializeCmd | read-write | current |
| ocnCrntPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.85 | InitializeCmd | read-write | current |
| ocnCrntPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.86 | InitializeCmd | read-write | current |
| ocnCrntPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.87 | InitializeCmd | read-write | current |
| ocnCrntPMOTNBERValue OBJECT-TYPE The instantaneous BER of OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.88 | DisplayString | read-only | current |
| ocnCrntPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.89 | DateAndTime | read-only | current |
| ocnCrntPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.90 | PMValidity | read-only | current |
| ocnCrntPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.91 | InitializeCmd | read-write | current |
| ocnCrntPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.92 | DisplayString | read-only | current |
| ocnCrntPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.93 | DateAndTime | read-only | current |
| ocnCrntPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.94 | PMValidity | read-only | current |
| ocnCrntPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.95 | InitializeCmd | read-write | current |
| ocnCrntPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.96 | Unsigned64 | read-only | current |
| ocnCrntPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.97 | DateAndTime | read-only | current |
| ocnCrntPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.98 | PMValidity | read-only | current |
| ocnCrntPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.99 | InitializeCmd | read-write | current |
| ocnCrntPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.100 | Unsigned64 | read-only | current |
| ocnCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.101 | DateAndTime | read-only | current |
| ocnCrntPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.102 | PMValidity | read-only | current |
| ocnCrntPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.103 | InitializeCmd | read-write | current |
| ocnCrntPMUASSValue OBJECT-TYPE The count of unavailable seconds at the section layer. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.104 | Unsigned32 | read-write | current |
| ocnCrntPMUASSTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds at the section layer | 1.3.6.1.4.1.18070.2.2.1.6.8.1.105 | DateAndTime | read-only | current |
| ocnCrntPMUASSValidity OBJECT-TYPE Indicates the validity of the unavailable seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.106 | PMValidity | read-only | current |
| ocnCrntPMUASSInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMUASSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.107 | InitializeCmd | read-write | current |
| ocnCrntPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.108 | Unsigned32 | read-write | current |
| ocnCrntPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.109 | DateAndTime | read-only | current |
| ocnCrntPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.110 | PMValidity | read-only | current |
| ocnCrntPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.111 | InitializeCmd | read-write | current |
| ocnCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.112 | FixedX10 | read-only | current |
| ocnCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.113 | DateAndTime | read-only | current |
| ocnCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.114 | PMValidity | read-only | current |
| ocnCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.115 | InitializeCmd | read-write | current |
| ocnCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.116 | FixedX10 | read-only | current |
| ocnCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.117 | DateAndTime | read-only | current |
| ocnCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.118 | PMValidity | read-only | current |
| ocnCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.119 | InitializeCmd | read-write | current |
| ocnCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.120 | FixedX10 | read-only | current |
| ocnCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.121 | DateAndTime | read-only | current |
| ocnCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.122 | PMValidity | read-only | current |
| ocnCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.123 | InitializeCmd | read-write | current |
| ocnCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.124 | FixedX10 | read-only | current |
| ocnCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.125 | DateAndTime | read-only | current |
| ocnCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.126 | PMValidity | read-only | current |
| ocnCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.127 | InitializeCmd | read-write | current |
| ocnCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.128 | FixedX10 | read-only | current |
| ocnCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.129 | DateAndTime | read-only | current |
| ocnCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.130 | PMValidity | read-only | current |
| ocnCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.131 | InitializeCmd | read-write | current |
| ocnCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.132 | FixedX10 | read-only | current |
| ocnCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.133 | DateAndTime | read-only | current |
| ocnCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.134 | PMValidity | read-only | current |
| ocnCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the ocnCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.8.1.135 | InitializeCmd | read-write | current |
| ocnHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the SONET OC-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.9 | not-accessible | current | |
| ocnHistPMEntry OBJECT-TYPE The row entry object of the SONET OC-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.9.1 | not-accessible | current | |
| ocnHistPMTypeIdx OBJECT-TYPE The type of the OC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.1 | OcnType | not-accessible | current |
| ocnHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnHistPMSlotIdx OBJECT-TYPE The number of the slot within which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.3 | INTEGER (1..20) | not-accessible | current |
| ocnHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.4 | INTEGER (1..6) | not-accessible | current |
| ocnHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.5 | PMIntervalType | not-accessible | current |
| ocnHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.6 | INTEGER (1..96) | not-accessible | current |
| ocnHistPMOPRValue OBJECT-TYPE The optical power received on the input of the OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.7 | FixedX10 | read-only | current |
| ocnHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.8 | DateAndTime | read-only | current |
| ocnHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.9 | PMValidity | read-only | current |
| ocnHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.10 | FixedX10 | read-only | current |
| ocnHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.11 | DateAndTime | read-only | current |
| ocnHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.12 | PMValidity | read-only | current |
| ocnHistPMTempValue OBJECT-TYPE The temperature measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.13 | INTEGER (-32768..32767) | read-only | current |
| ocnHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.14 | DateAndTime | read-only | current |
| ocnHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.15 | PMValidity | read-only | current |
| ocnHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.16 | FixedX10 | read-only | current |
| ocnHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.17 | DateAndTime | read-only | current |
| ocnHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.18 | PMValidity | read-only | current |
| ocnHistPMLBCValue OBJECT-TYPE The laser bias current measured on the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.19 | INTEGER (-32768..32767) | read-only | current |
| ocnHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.20 | DateAndTime | read-only | current |
| ocnHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.21 | PMValidity | read-only | current |
| ocnHistPMCVSValue OBJECT-TYPE The count of coding violations at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.22 | Unsigned32 | read-write | current |
| ocnHistPMCVSTimeStamp OBJECT-TYPE The date and time stamp of the section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.23 | DateAndTime | read-only | current |
| ocnHistPMCVSValidity OBJECT-TYPE Indicates the validity of the provided section layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.24 | PMValidity | read-only | current |
| ocnHistPMESSValue OBJECT-TYPE The count of errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.25 | Unsigned32 | read-write | current |
| ocnHistPMESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.26 | DateAndTime | read-only | current |
| ocnHistPMESSValidity OBJECT-TYPE Indicates the validity of the provided section layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.27 | PMValidity | read-only | current |
| ocnHistPMSESSValue OBJECT-TYPE The count of severely errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.28 | Unsigned32 | read-write | current |
| ocnHistPMSESSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.29 | DateAndTime | read-only | current |
| ocnHistPMSESSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.30 | PMValidity | read-only | current |
| ocnHistPMSEFSSValue OBJECT-TYPE The count of severely errored framing seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.31 | Unsigned32 | read-write | current |
| ocnHistPMSEFSSTimeStamp OBJECT-TYPE The date and time stamp of the section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.32 | DateAndTime | read-only | current |
| ocnHistPMSEFSSValidity OBJECT-TYPE Indicates the validity of the provided section layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.33 | PMValidity | read-only | current |
| ocnHistPMSupplyVoltage2Value OBJECT-TYPE The value of the second supply voltage source measured on the OC-N facility port transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.34 | FixedX10 | read-only | current |
| ocnHistPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.35 | DateAndTime | read-only | current |
| ocnHistPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.36 | PMValidity | read-only | current |
| ocnHistPMCVLValue OBJECT-TYPE The count of coding violations at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.37 | Unsigned32 | read-write | current |
| ocnHistPMCVLTimeStamp OBJECT-TYPE The date and time stamp of the line layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.38 | DateAndTime | read-only | current |
| ocnHistPMCVLValidity OBJECT-TYPE Indicates the validity of the provided line layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.39 | PMValidity | read-only | current |
| ocnHistPMESLValue OBJECT-TYPE The count of errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.40 | Unsigned32 | read-write | current |
| ocnHistPMESLTimeStamp OBJECT-TYPE The date and time stamp of the line layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.41 | DateAndTime | read-only | current |
| ocnHistPMESLValidity OBJECT-TYPE Indicates the validity of the provided line layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.42 | PMValidity | read-only | current |
| ocnHistPMSESLValue OBJECT-TYPE The count of severely errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.43 | Unsigned32 | read-write | current |
| ocnHistPMSESLTimeStamp OBJECT-TYPE The date and time stamp of the line layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.44 | DateAndTime | read-only | current |
| ocnHistPMSESLValidity OBJECT-TYPE Indicates the validity of the provided line layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.45 | PMValidity | read-only | current |
| ocnHistPMUASLValue OBJECT-TYPE The count of unavailable seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.46 | Unsigned32 | read-write | current |
| ocnHistPMUASLTimeStamp OBJECT-TYPE The date and time stamp of the line layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.47 | DateAndTime | read-only | current |
| ocnHistPMUASLValidity OBJECT-TYPE Indicates the validity of the provided line layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.48 | PMValidity | read-only | current |
| ocnHistPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.49 | Unsigned32 | read-write | current |
| ocnHistPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.50 | DateAndTime | read-only | current |
| ocnHistPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.51 | PMValidity | read-only | current |
| ocnHistPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.52 | Unsigned32 | read-write | current |
| ocnHistPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.53 | DateAndTime | read-only | current |
| ocnHistPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.54 | PMValidity | read-only | current |
| ocnHistPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.55 | Unsigned32 | read-write | current |
| ocnHistPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.56 | DateAndTime | read-only | current |
| ocnHistPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.57 | PMValidity | read-only | current |
| ocnHistPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.58 | Unsigned32 | read-write | current |
| ocnHistPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.59 | DateAndTime | read-only | current |
| ocnHistPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.60 | PMValidity | read-only | current |
| ocnHistPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.61 | Unsigned32 | read-write | current |
| ocnHistPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.62 | DateAndTime | read-only | current |
| ocnHistPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.63 | PMValidity | read-only | current |
| ocnHistPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.64 | Unsigned32 | read-write | current |
| ocnHistPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.65 | DateAndTime | read-only | current |
| ocnHistPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.66 | PMValidity | read-only | current |
| ocnHistPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.67 | Unsigned32 | read-write | current |
| ocnHistPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.68 | DateAndTime | read-only | current |
| ocnHistPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.69 | PMValidity | read-only | current |
| ocnHistPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.70 | Unsigned32 | read-write | current |
| ocnHistPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.71 | DateAndTime | read-only | current |
| ocnHistPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.72 | PMValidity | read-only | current |
| ocnHistPMCVSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMCVSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.73 | InitializeCmd | read-write | current |
| ocnHistPMESSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.74 | InitializeCmd | read-write | current |
| ocnHistPMSESSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMSESSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.75 | InitializeCmd | read-write | current |
| ocnHistPMSEFSSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMSEFSSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.76 | InitializeCmd | read-write | current |
| ocnHistPMCVLInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMCVLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.77 | InitializeCmd | read-write | current |
| ocnHistPMESLInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMESLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.78 | InitializeCmd | read-write | current |
| ocnHistPMSESLInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMSESLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.79 | InitializeCmd | read-write | current |
| ocnHistPMUASLInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMUASLValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.80 | InitializeCmd | read-write | current |
| ocnHistPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.81 | InitializeCmd | read-write | current |
| ocnHistPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.82 | InitializeCmd | read-write | current |
| ocnHistPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.83 | InitializeCmd | read-write | current |
| ocnHistPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.84 | InitializeCmd | read-write | current |
| ocnHistPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.85 | InitializeCmd | read-write | current |
| ocnHistPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.86 | InitializeCmd | read-write | current |
| ocnHistPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.87 | InitializeCmd | read-write | current |
| ocnHistPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.88 | InitializeCmd | read-write | current |
| ocnHistPMOTNBERValue OBJECT-TYPE The instantaneous BER of OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.89 | DisplayString | read-only | current |
| ocnHistPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.90 | DateAndTime | read-only | current |
| ocnHistPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.91 | PMValidity | read-only | current |
| ocnHistPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.92 | InitializeCmd | read-write | current |
| ocnHistPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.93 | DisplayString | read-only | current |
| ocnHistPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.94 | DateAndTime | read-only | current |
| ocnHistPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.95 | PMValidity | read-only | current |
| ocnHistPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.96 | InitializeCmd | read-write | current |
| ocnHistPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.97 | Unsigned64 | read-only | current |
| ocnHistPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.98 | DateAndTime | read-only | current |
| ocnHistPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.99 | PMValidity | read-only | current |
| ocnHistPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.100 | InitializeCmd | read-write | current |
| ocnHistPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.101 | Unsigned64 | read-only | current |
| ocnHistPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.102 | DateAndTime | read-only | current |
| ocnHistPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.103 | PMValidity | read-only | current |
| ocnHistPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.104 | InitializeCmd | read-write | current |
| ocnHistPMUASSValue OBJECT-TYPE The count of unavailable seconds at the section layer. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.105 | Unsigned32 | read-write | current |
| ocnHistPMUASSTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.106 | DateAndTime | read-only | current |
| ocnHistPMUASSValidity OBJECT-TYPE Indicates the validity of the unavailable seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.107 | PMValidity | read-only | current |
| ocnHistPMUASSInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMUASSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.108 | InitializeCmd | read-write | current |
| ocnHistPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.109 | Unsigned32 | read-write | current |
| ocnHistPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.110 | DateAndTime | read-only | current |
| ocnHistPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.111 | PMValidity | read-only | current |
| ocnHistPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.112 | InitializeCmd | read-write | current |
| ocnHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.113 | FixedX10 | read-only | current |
| ocnHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.114 | DateAndTime | read-only | current |
| ocnHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.115 | PMValidity | read-only | current |
| ocnHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.116 | InitializeCmd | read-write | current |
| ocnHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.117 | FixedX10 | read-only | current |
| ocnHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.118 | DateAndTime | read-only | current |
| ocnHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.119 | PMValidity | read-only | current |
| ocnHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.120 | InitializeCmd | read-write | current |
| ocnHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.121 | FixedX10 | read-only | current |
| ocnHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.122 | DateAndTime | read-only | current |
| ocnHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.123 | PMValidity | read-only | current |
| ocnHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.124 | InitializeCmd | read-write | current |
| ocnHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.125 | FixedX10 | read-only | current |
| ocnHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.126 | DateAndTime | read-only | current |
| ocnHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.127 | PMValidity | read-only | current |
| ocnHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.128 | InitializeCmd | read-write | current |
| ocnHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.129 | FixedX10 | read-only | current |
| ocnHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.130 | DateAndTime | read-only | current |
| ocnHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.131 | PMValidity | read-only | current |
| ocnHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.132 | InitializeCmd | read-write | current |
| ocnHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.133 | FixedX10 | read-only | current |
| ocnHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.134 | DateAndTime | read-only | current |
| ocnHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.135 | PMValidity | read-only | current |
| ocnHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the ocnHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.9.1.136 | InitializeCmd | read-write | current |
| ocnPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on SONET OC-N facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.10 | not-accessible | current | |
| ocnPMThresholdEntry OBJECT-TYPE The row entry object of the SONET OC-N performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual OC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.10.1 | not-accessible | current | |
| ocnPMThresholdTypeIdx OBJECT-TYPE The type of the OC-N facility targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.1 | OcnType | not-accessible | current |
| ocnPMThresholdShelfIdx OBJECT-TYPE The shelf number on which the OC-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnPMThresholdSlotIdx OBJECT-TYPE The slot number on which the OC-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.3 | INTEGER (1..20) | not-accessible | current |
| ocnPMThresholdPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.4 | INTEGER (1..6) | not-accessible | current |
| ocnPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.5 | PMIntervalType | not-accessible | current |
| ocnPMThresholdCVSValue OBJECT-TYPE The threshold for the count of coding violations at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.6 | Unsigned32 | read-write | current |
| ocnPMThresholdESSValue OBJECT-TYPE The threshold for the count of errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.7 | Unsigned32 | read-write | current |
| ocnPMThresholdSESSValue OBJECT-TYPE The threshold fro the count of severely errored seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.8 | Unsigned32 | read-write | current |
| ocnPMThresholdSEFSSValue OBJECT-TYPE The threshold for the count of severely errored framing seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.9 | Unsigned32 | read-write | current |
| ocnPMThresholdCVLValue OBJECT-TYPE The threshold for the count of coding violations at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.10 | Unsigned32 | read-write | current |
| ocnPMThresholdESLValue OBJECT-TYPE The threshold for the count of errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.11 | Unsigned32 | read-write | current |
| ocnPMThresholdSESLValue OBJECT-TYPE The threshold for the count of severely errored seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.12 | Unsigned32 | read-write | current |
| ocnPMThresholdUASLValue OBJECT-TYPE The threshold for the count of unavailable seconds at the line layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.13 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUEBValue OBJECT-TYPE The threshold for the count of errored blocks at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.14 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUBBEValue OBJECT-TYPE The threshold for the count of background block errors at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.15 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUESValue OBJECT-TYPE The threshold for the count of errored seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.16 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUSESValue OBJECT-TYPE The threshold for the count of severely errored seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.17 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUOFSValue OBJECT-TYPE The threshold for the count of out-of-frame seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.18 | Unsigned32 | read-write | current |
| ocnPMThresholdUNCRCDWValue OBJECT-TYPE The threshold for the count of uncorrectable codewords. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.21 | Unsigned32 | read-write | current |
| ocnPMThresholdUASSValue OBJECT-TYPE The threshold for the count of unavailable seconds at the section layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.22 | Unsigned32 | read-write | current |
| ocnPMThresholdOTUUASValue OBJECT-TYPE The threshold for the count of unavailable seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.10.1.23 | Unsigned32 | read-write | current |
| stsnCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the SONET STS-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.11 | not-accessible | current | |
| stsnCrntPMEntry OBJECT-TYPE The row entry object of the SONET STS-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given STS-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.11.1 | not-accessible | current | |
| stsnCrntPMTypeIdx OBJECT-TYPE The type of STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.1 | StsnType | not-accessible | current |
| stsnCrntPMShelfIdx OBJECT-TYPE The number of the shelf of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnCrntPMSlotIdx OBJECT-TYPE The number of the slot of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.3 | INTEGER (1..20) | not-accessible | current |
| stsnCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.4 | INTEGER (1..2) | not-accessible | current |
| stsnCrntPMIdx OBJECT-TYPE The sts index number of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.5 | INTEGER (1..192) | not-accessible | current |
| stsnCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.6 | PMIntervalType | not-accessible | current |
| stsnCrntPMCVPValue OBJECT-TYPE The count of coding violations at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.7 | Unsigned32 | read-write | current |
| stsnCrntPMCVPTimeStamp OBJECT-TYPE The date and time stamp of the path layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.8 | DateAndTime | read-only | current |
| stsnCrntPMCVPValidity OBJECT-TYPE Indicates the validity of the provided path layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.9 | PMValidity | read-only | current |
| stsnCrntPMESPValue OBJECT-TYPE The count of errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.10 | Unsigned32 | read-write | current |
| stsnCrntPMESPTimeStamp OBJECT-TYPE The date and time stamp of the path layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.11 | DateAndTime | read-only | current |
| stsnCrntPMESPValidity OBJECT-TYPE Indicates the validity of the provided path layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.12 | PMValidity | read-only | current |
| stsnCrntPMSESPValue OBJECT-TYPE The count of severely errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.13 | Unsigned32 | read-write | current |
| stsnCrntPMSESPTimeStamp OBJECT-TYPE The date and time stamp of the path layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.14 | DateAndTime | read-only | current |
| stsnCrntPMSESPValidity OBJECT-TYPE Indicates the validity of the provided path layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.15 | PMValidity | read-only | current |
| stsnCrntPMUASPValue OBJECT-TYPE The count of unavailable seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.16 | Unsigned32 | read-write | current |
| stsnCrntPMUASPTimeStamp OBJECT-TYPE The date and time stamp of the path layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.17 | DateAndTime | read-only | current |
| stsnCrntPMUASPValidity OBJECT-TYPE Indicates the validity of the provided path layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.18 | PMValidity | read-only | current |
| stsnCrntPMFCPValue OBJECT-TYPE The failure count at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.19 | Unsigned32 | read-write | current |
| stsnCrntPMFCPTimeStamp OBJECT-TYPE The date and time stamp of the path layer failure count value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.20 | DateAndTime | read-only | current |
| stsnCrntPMFCPValidity OBJECT-TYPE Indicates the validity of the provided path layer failure count value. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.21 | PMValidity | read-only | current |
| stsnCrntPMCVPInitialize OBJECT-TYPE Used to initialize the value of the stsnCrntPMCVPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.22 | InitializeCmd | read-write | current |
| stsnCrntPMESPInitialize OBJECT-TYPE Used to initialize the value of the stsnCrntPMESPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.23 | InitializeCmd | read-write | current |
| stsnCrntPMSESPInitialize OBJECT-TYPE Used to initialize the value of the stsnCrntPMSESPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.24 | InitializeCmd | read-write | current |
| stsnCrntPMUASPInitialize OBJECT-TYPE Used to initialize the value of the stsnCrntPMUASPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.25 | InitializeCmd | read-write | current |
| stsnCrntPMFCPInitialize OBJECT-TYPE Used to initialize the value of the stsnCrntPMFCPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.11.1.26 | InitializeCmd | read-write | current |
| stsnHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the SONET STS-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.12 | not-accessible | current | |
| stsnHistPMEntry OBJECT-TYPE The row entry object of the SONET STS-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given STS-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.12.1 | not-accessible | current | |
| stsnHistPMTypeIdx OBJECT-TYPE The type of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.1 | StsnType | not-accessible | current |
| stsnHistPMShelfIdx OBJECT-TYPE The number of the shelf of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnHistPMSlotIdx OBJECT-TYPE The number of the slot of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.3 | INTEGER (1..20) | not-accessible | current |
| stsnHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.4 | INTEGER (1..2) | not-accessible | current |
| stsnHistPMIdx OBJECT-TYPE The sts index number of the STS-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.5 | INTEGER (1..192) | not-accessible | current |
| stsnHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.6 | PMIntervalType | not-accessible | current |
| stsnHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.7 | INTEGER (1..96) | not-accessible | current |
| stsnHistPMCVPValue OBJECT-TYPE The count of coding violations at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.8 | Unsigned32 | read-write | current |
| stsnHistPMCVPTimeStamp OBJECT-TYPE The date and time stamp of the path layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.9 | DateAndTime | read-only | current |
| stsnHistPMCVPValidity OBJECT-TYPE Indicates the validity of the provided path layer coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.10 | PMValidity | read-only | current |
| stsnHistPMESPValue OBJECT-TYPE The count of errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.11 | Unsigned32 | read-write | current |
| stsnHistPMESPTimeStamp OBJECT-TYPE The date and time stamp of the path layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.12 | DateAndTime | read-only | current |
| stsnHistPMESPValidity OBJECT-TYPE Indicates the validity of the provided path layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.13 | PMValidity | read-only | current |
| stsnHistPMSESPValue OBJECT-TYPE The count of severely errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.14 | Unsigned32 | read-write | current |
| stsnHistPMSESPTimeStamp OBJECT-TYPE The date and time stamp of the path layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.15 | DateAndTime | read-only | current |
| stsnHistPMSESPValidity OBJECT-TYPE Indicates the validity of the provided path layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.16 | PMValidity | read-only | current |
| stsnHistPMUASPValue OBJECT-TYPE The count of unavailable seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.17 | Unsigned32 | read-write | current |
| stsnHistPMUASPTimeStamp OBJECT-TYPE The date and time stamp of the path layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.18 | DateAndTime | read-only | current |
| stsnHistPMUASPValidity OBJECT-TYPE Indicates the validity of the provided path layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.19 | PMValidity | read-only | current |
| stsnHistPMFCPValue OBJECT-TYPE The failure count at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.20 | Unsigned32 | read-write | current |
| stsnHistPMFCPTimeStamp OBJECT-TYPE The date and time stamp of the path layer failure count. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.21 | DateAndTime | read-only | current |
| stsnHistPMFCPValidity OBJECT-TYPE Indicates the validity of the provided path layer failure count. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.22 | PMValidity | read-only | current |
| stsnHistPMCVPInitialize OBJECT-TYPE Used to initialize the value of the stsnHistPMCVPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.23 | InitializeCmd | read-write | current |
| stsnHistPMESPInitialize OBJECT-TYPE Used to initialize the value of the stsnHistPMESPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.24 | InitializeCmd | read-write | current |
| stsnHistPMSESPInitialize OBJECT-TYPE Used to initialize the value of the stsnHistPMSESPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.25 | InitializeCmd | read-write | current |
| stsnHistPMUASPInitialize OBJECT-TYPE Used to initialize the value of the stsnHistPMUASPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.26 | InitializeCmd | read-write | current |
| stsnHistPMFCPInitialize OBJECT-TYPE Used to initialize the value of the stsnHistPMFCPValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.12.1.27 | InitializeCmd | read-write | current |
| stsnPMThresholdByPortTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on SONET STS-N facilities, that are used in the generation of threshold crossing alerts. The STS-N threshold settings will be the same for all STS channels on a given OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.13 | not-accessible | current | |
| stsnPMThresholdByPortEntry OBJECT-TYPE The row entry object of the SONET STS-N performance monitoring threshold by port table. Each row of this table contains a set of PM thresholds for a given interval type that applies to all the STS-N channels on an OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.13.1 | not-accessible | current | |
| stsnPMThresholdByPortTypeIdx OBJECT-TYPE The type of the STS-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.1 | StsnType | not-accessible | current |
| stsnPMThresholdByPortShelfIdx OBJECT-TYPE The shelf number of the STS-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnPMThresholdByPortSlotIdx OBJECT-TYPE The slot number of the STS-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.3 | INTEGER (1..20) | not-accessible | current |
| stsnPMThresholdByPortIdx OBJECT-TYPE The number of the port on the circuit pack of the STS-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.4 | INTEGER (1..2) | not-accessible | current |
| stsnPMThresholdByPortIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.5 | PMIntervalType | not-accessible | current |
| stsnPMThresholdByPortCVPValue OBJECT-TYPE The threshold for the count of coding violations at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.6 | Unsigned32 | read-write | current |
| stsnPMThresholdByPortESPValue OBJECT-TYPE The threshold for the count of errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.9 | Unsigned32 | read-write | current |
| stsnPMThresholdByPortSESPValue OBJECT-TYPE The threshold for the count of severely errored seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.10 | Unsigned32 | read-write | current |
| stsnPMThresholdByPortUASPValue OBJECT-TYPE The threshold for the count of unavailable seconds at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.11 | Unsigned32 | read-write | current |
| stsnPMThresholdByPortFCPValue OBJECT-TYPE The threshold for the failure count at the path layer. | 1.3.6.1.4.1.18070.2.2.1.6.13.1.12 | Unsigned32 | read-write | current |
| stmnCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the SDH STM-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.14 | not-accessible | current | |
| stmnCrntPMEntry OBJECT-TYPE The row entry object of the SDH STM-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.14.1 | not-accessible | current | |
| stmnCrntPMTypeIdx OBJECT-TYPE The type of STM-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.1 | StmnType | not-accessible | current |
| stmnCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.3 | INTEGER (1..20) | not-accessible | current |
| stmnCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.4 | INTEGER (1..6) | not-accessible | current |
| stmnCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.5 | PMIntervalType | not-accessible | current |
| stmnCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the OC-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.6 | FixedX10 | read-only | current |
| stmnCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.7 | DateAndTime | read-only | current |
| stmnCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.8 | PMValidity | read-only | current |
| stmnCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.9 | FixedX10 | read-only | current |
| stmnCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.10 | DateAndTime | read-only | current |
| stmnCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.11 | PMValidity | read-only | current |
| stmnCrntPMTempValue OBJECT-TYPE The temperature measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.12 | INTEGER (-32768..32767) | read-only | current |
| stmnCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.13 | DateAndTime | read-only | current |
| stmnCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.14 | PMValidity | read-only | current |
| stmnCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.15 | FixedX10 | read-only | current |
| stmnCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.16 | DateAndTime | read-only | current |
| stmnCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.17 | PMValidity | read-only | current |
| stmnCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.18 | INTEGER (-32768..32767) | read-only | current |
| stmnCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.19 | DateAndTime | read-only | current |
| stmnCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.20 | PMValidity | read-only | current |
| stmnCrntPMRSEBValue OBJECT-TYPE The count of regenerator section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.21 | Unsigned32 | read-write | current |
| stmnCrntPMRSEBTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.22 | DateAndTime | read-only | current |
| stmnCrntPMRSEBValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.23 | PMValidity | read-only | current |
| stmnCrntPMRSBBEValue OBJECT-TYPE The count of regenerator section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.24 | Unsigned32 | read-write | current |
| stmnCrntPMRSBBETimeStamp OBJECT-TYPE The date and time stamp of the regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.25 | DateAndTime | read-only | current |
| stmnCrntPMRSBBEValidity OBJECT-TYPE Indicates the validity of the provided regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.26 | PMValidity | read-only | current |
| stmnCrntPMRSESValue OBJECT-TYPE The count of regenerator section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.27 | Unsigned32 | read-write | current |
| stmnCrntPMRSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.28 | DateAndTime | read-only | current |
| stmnCrntPMRSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.29 | PMValidity | read-only | current |
| stmnCrntPMRSSESValue OBJECT-TYPE The count of regenerator section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.30 | Unsigned32 | read-write | current |
| stmnCrntPMRSSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.31 | DateAndTime | read-only | current |
| stmnCrntPMRSSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.32 | PMValidity | read-only | current |
| stmnCrntPMRSOFSValue OBJECT-TYPE The count of regenerator section out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.33 | Unsigned32 | read-write | current |
| stmnCrntPMRSOFSTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.34 | DateAndTime | read-only | current |
| stmnCrntPMRSOFSValidity OBJECT-TYPE Indicates the validity of the provided regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.35 | PMValidity | read-only | current |
| stmnCrntPMSupplyVoltage2Value OBJECT-TYPE The value of the second supply voltage source measured on the STM-N facility port transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.36 | FixedX10 | read-only | current |
| stmnCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.37 | DateAndTime | read-only | current |
| stmnCrntPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.38 | PMValidity | read-only | current |
| stmnCrntPMMSEBValue OBJECT-TYPE The count of multiplex section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.39 | Unsigned32 | read-write | current |
| stmnCrntPMMSEBTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.40 | DateAndTime | read-only | current |
| stmnCrntPMMSEBValidity OBJECT-TYPE Indicates the validity of the provided multiplex section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.41 | PMValidity | read-only | current |
| stmnCrntPMMSBBEValue OBJECT-TYPE The count of multiplex section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.42 | Unsigned32 | read-write | current |
| stmnCrntPMMSBBETimeStamp OBJECT-TYPE The date and time stamp of the multiplex section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.43 | DateAndTime | read-only | current |
| stmnCrntPMMSBBEValidity OBJECT-TYPE Indicates the validity of the provided multiplex section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.44 | PMValidity | read-only | current |
| stmnCrntPMMSESValue OBJECT-TYPE The count of multiplex section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.45 | Unsigned32 | read-write | current |
| stmnCrntPMMSESTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.46 | DateAndTime | read-only | current |
| stmnCrntPMMSESValidity OBJECT-TYPE Indicates the validity of the provided multiplex section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.47 | PMValidity | read-only | current |
| stmnCrntPMMSSESValue OBJECT-TYPE The count of multiplex section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.48 | Unsigned32 | read-write | current |
| stmnCrntPMMSSESTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.49 | DateAndTime | read-only | current |
| stmnCrntPMMSSESValidity OBJECT-TYPE Indicates the validity of the provided multiplex section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.50 | PMValidity | read-only | current |
| stmnCrntPMMSUASValue OBJECT-TYPE The count of multiplex section unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.51 | Unsigned32 | read-write | current |
| stmnCrntPMMSUASTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.52 | DateAndTime | read-only | current |
| stmnCrntPMMSUASValidity OBJECT-TYPE Indicates the validity of the provided multiplex section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.53 | PMValidity | read-only | current |
| stmnCrntPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.54 | Unsigned32 | read-write | current |
| stmnCrntPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.55 | DateAndTime | read-only | current |
| stmnCrntPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.56 | PMValidity | read-only | current |
| stmnCrntPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.57 | Unsigned32 | read-write | current |
| stmnCrntPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.58 | DateAndTime | read-only | current |
| stmnCrntPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.59 | PMValidity | read-only | current |
| stmnCrntPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.60 | Unsigned32 | read-write | current |
| stmnCrntPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.61 | DateAndTime | read-only | current |
| stmnCrntPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.62 | PMValidity | read-only | current |
| stmnCrntPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.63 | Unsigned32 | read-write | current |
| stmnCrntPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.64 | DateAndTime | read-only | current |
| stmnCrntPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.65 | PMValidity | read-only | current |
| stmnCrntPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.66 | Unsigned32 | read-write | current |
| stmnCrntPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.67 | DateAndTime | read-only | current |
| stmnCrntPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.68 | PMValidity | read-only | current |
| stmnCrntPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.69 | Unsigned32 | read-write | current |
| stmnCrntPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.70 | DateAndTime | read-only | current |
| stmnCrntPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.71 | PMValidity | read-only | current |
| stmnCrntPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.72 | Unsigned32 | read-write | current |
| stmnCrntPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.73 | DateAndTime | read-only | current |
| stmnCrntPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.74 | PMValidity | read-only | current |
| stmnCrntPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.75 | Unsigned32 | read-write | current |
| stmnCrntPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.76 | DateAndTime | read-only | current |
| stmnCrntPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.77 | PMValidity | read-only | current |
| stmnCrntPMRSEBInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.78 | InitializeCmd | read-write | current |
| stmnCrntPMRSBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.79 | InitializeCmd | read-write | current |
| stmnCrntPMRSESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.80 | InitializeCmd | read-write | current |
| stmnCrntPMRSSESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.81 | InitializeCmd | read-write | current |
| stmnCrntPMRSOFSInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.82 | InitializeCmd | read-write | current |
| stmnCrntPMMSEBInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMMSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.83 | InitializeCmd | read-write | current |
| stmnCrntPMMSBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMMSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.84 | InitializeCmd | read-write | current |
| stmnCrntPMMSESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.85 | InitializeCmd | read-write | current |
| stmnCrntPMMSSESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMMSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.86 | InitializeCmd | read-write | current |
| stmnCrntPMMSUASInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMMSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.87 | InitializeCmd | read-write | current |
| stmnCrntPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.88 | InitializeCmd | read-write | current |
| stmnCrntPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.89 | InitializeCmd | read-write | current |
| stmnCrntPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.90 | InitializeCmd | read-write | current |
| stmnCrntPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.91 | InitializeCmd | read-write | current |
| stmnCrntPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.92 | InitializeCmd | read-write | current |
| stmnCrntPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.93 | InitializeCmd | read-write | current |
| stmnCrntPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.94 | InitializeCmd | read-write | current |
| stmnCrntPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.95 | InitializeCmd | read-write | current |
| stmnCrntPMOTNBERValue OBJECT-TYPE The instantaneous BER of STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.96 | DisplayString | read-only | current |
| stmnCrntPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.97 | DateAndTime | read-only | current |
| stmnCrntPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.98 | PMValidity | read-only | current |
| stmnCrntPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.99 | InitializeCmd | read-write | current |
| stmnCrntPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.100 | DisplayString | read-only | current |
| stmnCrntPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.101 | DateAndTime | read-only | current |
| stmnCrntPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.102 | PMValidity | read-only | current |
| stmnCrntPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.103 | InitializeCmd | read-write | current |
| stmnCrntPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.104 | Unsigned64 | read-only | current |
| stmnCrntPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.105 | DateAndTime | read-only | current |
| stmnCrntPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.106 | PMValidity | read-only | current |
| stmnCrntPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.107 | InitializeCmd | read-write | current |
| stmnCrntPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.108 | Unsigned64 | read-only | current |
| stmnCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.109 | DateAndTime | read-only | current |
| stmnCrntPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.110 | PMValidity | read-only | current |
| stmnCrntPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.111 | InitializeCmd | read-write | current |
| stmnCrntPMRSUASValue OBJECT-TYPE The count of regenerator section unavailable seconds. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.112 | Unsigned32 | read-write | current |
| stmnCrntPMRSUASTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.113 | DateAndTime | read-only | current |
| stmnCrntPMRSUASValidity OBJECT-TYPE Indicates the validity of the provided regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.114 | PMValidity | read-only | current |
| stmnCrntPMRSUASInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMRSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.115 | InitializeCmd | read-write | current |
| stmnCrntPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.116 | Unsigned32 | read-write | current |
| stmnCrntPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.117 | DateAndTime | read-only | current |
| stmnCrntPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.118 | PMValidity | read-only | current |
| stmnCrntPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.119 | InitializeCmd | read-write | current |
| stmnCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.120 | FixedX10 | read-only | current |
| stmnCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.121 | DateAndTime | read-only | current |
| stmnCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.122 | PMValidity | read-only | current |
| stmnCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.123 | InitializeCmd | read-write | current |
| stmnCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.124 | FixedX10 | read-only | current |
| stmnCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.125 | DateAndTime | read-only | current |
| stmnCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.126 | PMValidity | read-only | current |
| stmnCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.127 | InitializeCmd | read-write | current |
| stmnCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.128 | FixedX10 | read-only | current |
| stmnCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.129 | DateAndTime | read-only | current |
| stmnCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.130 | PMValidity | read-only | current |
| stmnCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.131 | InitializeCmd | read-write | current |
| stmnCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.132 | FixedX10 | read-only | current |
| stmnCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.133 | DateAndTime | read-only | current |
| stmnCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.134 | PMValidity | read-only | current |
| stmnCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.135 | InitializeCmd | read-write | current |
| stmnCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.136 | FixedX10 | read-only | current |
| stmnCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.137 | DateAndTime | read-only | current |
| stmnCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.138 | PMValidity | read-only | current |
| stmnCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.139 | InitializeCmd | read-write | current |
| stmnCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.140 | FixedX10 | read-only | current |
| stmnCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.141 | DateAndTime | read-only | current |
| stmnCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.142 | PMValidity | read-only | current |
| stmnCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.14.1.143 | InitializeCmd | read-write | current |
| stmnHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the SDH STM-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.15 | not-accessible | current | |
| stmnHistPMEntry OBJECT-TYPE The row entry object of the SDH STM-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.15.1 | not-accessible | current | |
| stmnHistPMTypeIdx OBJECT-TYPE The type of the STM-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.1 | StmnType | not-accessible | current |
| stmnHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnHistPMSlotIdx OBJECT-TYPE The number of the slot within which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.3 | INTEGER (1..20) | not-accessible | current |
| stmnHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.4 | INTEGER (1..6) | not-accessible | current |
| stmnHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.5 | PMIntervalType | not-accessible | current |
| stmnHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.6 | INTEGER (1..96) | not-accessible | current |
| stmnHistPMOPRValue OBJECT-TYPE The optical power received on the input of the STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.7 | FixedX10 | read-only | current |
| stmnHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.8 | DateAndTime | read-only | current |
| stmnHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.9 | PMValidity | read-only | current |
| stmnHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.10 | FixedX10 | read-only | current |
| stmnHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.11 | DateAndTime | read-only | current |
| stmnHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.12 | PMValidity | read-only | current |
| stmnHistPMTempValue OBJECT-TYPE The temperature measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.13 | INTEGER (-32768..32767) | read-only | current |
| stmnHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.14 | DateAndTime | read-only | current |
| stmnHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.15 | PMValidity | read-only | current |
| stmnHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.16 | FixedX10 | read-only | current |
| stmnHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.17 | DateAndTime | read-only | current |
| stmnHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.18 | PMValidity | read-only | current |
| stmnHistPMLBCValue OBJECT-TYPE The laser bias current measured on the STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.19 | INTEGER (-32768..32767) | read-only | current |
| stmnHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.20 | DateAndTime | read-only | current |
| stmnHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.21 | PMValidity | read-only | current |
| stmnHistPMRSEBValue OBJECT-TYPE The count of regenerator section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.22 | Unsigned32 | read-write | current |
| stmnHistPMRSEBTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.23 | DateAndTime | read-only | current |
| stmnHistPMRSEBValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.24 | PMValidity | read-only | current |
| stmnHistPMRSBBEValue OBJECT-TYPE The count of regenerator section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.25 | Unsigned32 | read-write | current |
| stmnHistPMRSBBETimeStamp OBJECT-TYPE The date and time stamp of the regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.26 | DateAndTime | read-only | current |
| stmnHistPMRSBBEValidity OBJECT-TYPE Indicates the validity of the provided regenerator section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.27 | PMValidity | read-only | current |
| stmnHistPMRSESValue OBJECT-TYPE The count of regenerator section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.28 | Unsigned32 | read-write | current |
| stmnHistPMRSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.29 | DateAndTime | read-only | current |
| stmnHistPMRSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.30 | PMValidity | read-only | current |
| stmnHistPMRSSESValue OBJECT-TYPE The count of regenerator section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.31 | Unsigned32 | read-write | current |
| stmnHistPMRSSESTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.32 | DateAndTime | read-only | current |
| stmnHistPMRSSESValidity OBJECT-TYPE Indicates the validity of the provided regenerator section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.33 | PMValidity | read-only | current |
| stmnHistPMRSOFSValue OBJECT-TYPE The count of regenerator section out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.34 | Unsigned32 | read-write | current |
| stmnHistPMRSOFSTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.35 | DateAndTime | read-only | current |
| stmnHistPMRSOFSValidity OBJECT-TYPE Indicates the validity of the provided regenerator section out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.36 | PMValidity | read-only | current |
| stmnHistPMSupplyVoltage2Value OBJECT-TYPE The value of the second supply voltage source measured on the STM-N facility port transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.37 | FixedX10 | read-only | current |
| stmnHistPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.38 | DateAndTime | read-only | current |
| stmnHistPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.39 | PMValidity | read-only | current |
| stmnHistPMMSEBValue OBJECT-TYPE The count of multiplex section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.40 | Unsigned32 | read-write | current |
| stmnHistPMMSEBTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.41 | DateAndTime | read-only | current |
| stmnHistPMMSEBValidity OBJECT-TYPE Indicates the validity of the provided multiplex section errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.42 | PMValidity | read-only | current |
| stmnHistPMMSBBEValue OBJECT-TYPE The count of multiplex section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.43 | Unsigned32 | read-write | current |
| stmnHistPMMSBBETimeStamp OBJECT-TYPE The date and time stamp of the multiplex section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.44 | DateAndTime | read-only | current |
| stmnHistPMMSBBEValidity OBJECT-TYPE Indicates the validity of the provided multiplex section background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.45 | PMValidity | read-only | current |
| stmnHistPMMSESValue OBJECT-TYPE The count of multiplex section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.46 | Unsigned32 | read-write | current |
| stmnHistPMMSESTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.47 | DateAndTime | read-only | current |
| stmnHistPMMSESValidity OBJECT-TYPE Indicates the validity of the provided multiplex section errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.48 | PMValidity | read-only | current |
| stmnHistPMMSSESValue OBJECT-TYPE The count of multiplex section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.49 | Unsigned32 | read-write | current |
| stmnHistPMMSSESTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.50 | DateAndTime | read-only | current |
| stmnHistPMMSSESValidity OBJECT-TYPE Indicates the validity of the provided multiplex section severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.51 | PMValidity | read-only | current |
| stmnHistPMMSUASValue OBJECT-TYPE The count of multiplex section unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.52 | Unsigned32 | read-write | current |
| stmnHistPMMSUASTimeStamp OBJECT-TYPE The date and time stamp of the multiplex section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.53 | DateAndTime | read-only | current |
| stmnHistPMMSUASValidity OBJECT-TYPE Indicates the validity of the provided multiplex section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.54 | PMValidity | read-only | current |
| stmnHistPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.55 | Unsigned32 | read-write | current |
| stmnHistPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.56 | DateAndTime | read-only | current |
| stmnHistPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.57 | PMValidity | read-only | current |
| stmnHistPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.58 | Unsigned32 | read-write | current |
| stmnHistPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.59 | DateAndTime | read-only | current |
| stmnHistPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.60 | PMValidity | read-only | current |
| stmnHistPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.61 | Unsigned32 | read-write | current |
| stmnHistPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.62 | DateAndTime | read-only | current |
| stmnHistPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.63 | PMValidity | read-only | current |
| stmnHistPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.64 | Unsigned32 | read-write | current |
| stmnHistPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.65 | DateAndTime | read-only | current |
| stmnHistPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.66 | PMValidity | read-only | current |
| stmnHistPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.67 | Unsigned32 | read-write | current |
| stmnHistPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.68 | DateAndTime | read-only | current |
| stmnHistPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored framing seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.69 | PMValidity | read-only | current |
| stmnHistPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.70 | Unsigned32 | read-write | current |
| stmnHistPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.71 | DateAndTime | read-only | current |
| stmnHistPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.72 | PMValidity | read-only | current |
| stmnHistPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.73 | Unsigned32 | read-write | current |
| stmnHistPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.74 | DateAndTime | read-only | current |
| stmnHistPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.75 | PMValidity | read-only | current |
| stmnHistPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.76 | Unsigned32 | read-write | current |
| stmnHistPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.77 | DateAndTime | read-only | current |
| stmnHistPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.78 | PMValidity | read-only | current |
| stmnHistPMRSEBInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.79 | InitializeCmd | read-write | current |
| stmnHistPMRSBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.80 | InitializeCmd | read-write | current |
| stmnHistPMRSESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.81 | InitializeCmd | read-write | current |
| stmnHistPMRSSESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.82 | InitializeCmd | read-write | current |
| stmnHistPMRSOFSInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.83 | InitializeCmd | read-write | current |
| stmnHistPMMSEBInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMMSEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.84 | InitializeCmd | read-write | current |
| stmnHistPMMSBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMMSBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.85 | InitializeCmd | read-write | current |
| stmnHistPMMSESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.86 | InitializeCmd | read-write | current |
| stmnHistPMMSSESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMMSSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.87 | InitializeCmd | read-write | current |
| stmnHistPMMSUASInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMMSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.88 | InitializeCmd | read-write | current |
| stmnHistPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.89 | InitializeCmd | read-write | current |
| stmnHistPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.90 | InitializeCmd | read-write | current |
| stmnHistPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.91 | InitializeCmd | read-write | current |
| stmnHistPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.92 | InitializeCmd | read-write | current |
| stmnHistPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.93 | InitializeCmd | read-write | current |
| stmnHistPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.94 | InitializeCmd | read-write | current |
| stmnHistPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.95 | InitializeCmd | read-write | current |
| stmnHistPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.96 | InitializeCmd | read-write | current |
| stmnHistPMOTNBERValue OBJECT-TYPE The instantaneous BER of STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.97 | DisplayString | read-only | current |
| stmnHistPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.98 | DateAndTime | read-only | current |
| stmnHistPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.99 | PMValidity | read-only | current |
| stmnHistPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.100 | InitializeCmd | read-write | current |
| stmnHistPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.101 | DisplayString | read-only | current |
| stmnHistPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.102 | DateAndTime | read-only | current |
| stmnHistPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.103 | PMValidity | read-only | current |
| stmnHistPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.104 | InitializeCmd | read-write | current |
| stmnHistPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.105 | Unsigned64 | read-only | current |
| stmnHistPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.106 | DateAndTime | read-only | current |
| stmnHistPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.107 | PMValidity | read-only | current |
| stmnHistPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.108 | InitializeCmd | read-write | current |
| stmnHistPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.109 | Unsigned64 | read-only | current |
| stmnHistPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.110 | DateAndTime | read-only | current |
| stmnHistPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.111 | PMValidity | read-only | current |
| stmnHistPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the stmnCrntPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.112 | InitializeCmd | read-write | current |
| stmnHistPMRSUASValue OBJECT-TYPE The count of regenerator section unavailable seconds. This object applies only to STM-64 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.113 | Unsigned32 | read-write | current |
| stmnHistPMRSUASTimeStamp OBJECT-TYPE The date and time stamp of the regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.114 | DateAndTime | read-only | current |
| stmnHistPMRSUASValidity OBJECT-TYPE Indicates the validity of the provided regenerator section unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.115 | PMValidity | read-only | current |
| stmnHistPMRSUASInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMRSUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.116 | InitializeCmd | read-write | current |
| stmnHistPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.117 | Unsigned32 | read-write | current |
| stmnHistPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.118 | DateAndTime | read-only | current |
| stmnHistPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.119 | PMValidity | read-only | current |
| stmnHistPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.120 | InitializeCmd | read-write | current |
| stmnHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.121 | FixedX10 | read-only | current |
| stmnHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.122 | DateAndTime | read-only | current |
| stmnHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.123 | PMValidity | read-only | current |
| stmnHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.124 | InitializeCmd | read-write | current |
| stmnHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.125 | FixedX10 | read-only | current |
| stmnHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.126 | DateAndTime | read-only | current |
| stmnHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.127 | PMValidity | read-only | current |
| stmnHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.128 | InitializeCmd | read-write | current |
| stmnHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.129 | FixedX10 | read-only | current |
| stmnHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.130 | DateAndTime | read-only | current |
| stmnHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.131 | PMValidity | read-only | current |
| stmnHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.132 | InitializeCmd | read-write | current |
| stmnHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.133 | FixedX10 | read-only | current |
| stmnHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.134 | DateAndTime | read-only | current |
| stmnHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.135 | PMValidity | read-only | current |
| stmnHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.136 | InitializeCmd | read-write | current |
| stmnHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.137 | FixedX10 | read-only | current |
| stmnHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.138 | DateAndTime | read-only | current |
| stmnHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.139 | PMValidity | read-only | current |
| stmnHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.140 | InitializeCmd | read-write | current |
| stmnHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.141 | FixedX10 | read-only | current |
| stmnHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.142 | DateAndTime | read-only | current |
| stmnHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.143 | PMValidity | read-only | current |
| stmnHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the stmnHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.15.1.144 | InitializeCmd | read-write | current |
| stmnPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on SDH STM-N facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.16 | not-accessible | current | |
| stmnPMThresholdEntry OBJECT-TYPE The row entry object of the SDH STM-N performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual STM-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.16.1 | not-accessible | current | |
| stmnPMThresholdTypeIdx OBJECT-TYPE The type of the STM-N facility targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.1 | StmnType | not-accessible | current |
| stmnPMThresholdShelfIdx OBJECT-TYPE The shelf number on which the STM-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnPMThresholdSlotIdx OBJECT-TYPE The slot number on which the STM-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.3 | INTEGER (1..20) | not-accessible | current |
| stmnPMThresholdPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.4 | INTEGER (1..6) | not-accessible | current |
| stmnPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.5 | PMIntervalType | not-accessible | current |
| stmnPMThresholdRSEBValue OBJECT-TYPE The threshold for the count of regenerator section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.6 | Unsigned32 | read-write | current |
| stmnPMThresholdRSBBEValue OBJECT-TYPE The threshold for the count of regenerator section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.7 | Unsigned32 | read-write | current |
| stmnPMThresholdRSESValue OBJECT-TYPE The threshold for the count of regenerator section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.8 | Unsigned32 | read-write | current |
| stmnPMThresholdRSSESValue OBJECT-TYPE The threshold for the count of regenerator section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.9 | Unsigned32 | read-write | current |
| stmnPMThresholdRSOFSValue OBJECT-TYPE The threshold for the count of regenerator section out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.10 | Unsigned32 | read-write | current |
| stmnPMThresholdMSEBValue OBJECT-TYPE The threshold for the count of multiplex section errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.11 | Unsigned32 | read-write | current |
| stmnPMThresholdMSBBEValue OBJECT-TYPE The threshold for the count of multiplex section background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.12 | Unsigned32 | read-write | current |
| stmnPMThresholdMSESValue OBJECT-TYPE The threshold for the count of multiplex section errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.13 | Unsigned32 | read-write | current |
| stmnPMThresholdMSSESValue OBJECT-TYPE The threshold for the count of multiplex section severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.14 | Unsigned32 | read-write | current |
| stmnPMThresholdMSUASValue OBJECT-TYPE The threshold for the count of multiplex section unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.15 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUEBValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.16 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUBBEValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.17 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUESValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.18 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUSESValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.19 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUOFSValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.20 | Unsigned32 | read-write | current |
| stmnPMThresholdUNCRCDWValue OBJECT-TYPE The threshold for the count of uncorrectable codewords. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.23 | Unsigned32 | read-write | current |
| stmnPMThresholdRSUASValue OBJECT-TYPE The threshold for the count of regenerator section unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.24 | Unsigned32 | read-write | current |
| stmnPMThresholdOTUUASValue OBJECT-TYPE The threshold for the count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.16.1.25 | Unsigned32 | read-write | current |
| vcnCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the SDH VC-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.17 | not-accessible | current | |
| vcnCrntPMEntry OBJECT-TYPE The row entry object of the SDH VC-N current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given VC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.17.1 | not-accessible | current | |
| vcnCrntPMTypeIdx OBJECT-TYPE The type of VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.1 | VcnType | not-accessible | current |
| vcnCrntPMShelfIdx OBJECT-TYPE The number of the shelf of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnCrntPMSlotIdx OBJECT-TYPE The number of the slot of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.3 | INTEGER (1..20) | not-accessible | current |
| vcnCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.4 | INTEGER (1..2) | not-accessible | current |
| vcnCrntPMIdx OBJECT-TYPE The channel number of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.5 | INTEGER (1..64) | not-accessible | current |
| vcnCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.6 | PMIntervalType | not-accessible | current |
| vcnCrntPMHPEBValue OBJECT-TYPE The count of high order path errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.7 | Unsigned32 | read-write | current |
| vcnCrntPMHPEBTimeStamp OBJECT-TYPE The date and time stamp of the high order path errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.8 | DateAndTime | read-only | current |
| vcnCrntPMHPEBValidity OBJECT-TYPE Indicates the validity of the provided high order path errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.9 | PMValidity | read-only | current |
| vcnCrntPMHPBBEValue OBJECT-TYPE The count of high order path background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.10 | Unsigned32 | read-write | current |
| vcnCrntPMHPBBETimeStamp OBJECT-TYPE The date and time stamp of the high order path background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.11 | DateAndTime | read-only | current |
| vcnCrntPMHPBBEValidity OBJECT-TYPE Indicates the validity of the provided high order path background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.12 | PMValidity | read-only | current |
| vcnCrntPMHPESValue OBJECT-TYPE The count of high order path errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.13 | Unsigned32 | read-write | current |
| vcnCrntPMHPESTimeStamp OBJECT-TYPE The date and time stamp of the high order path errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.14 | DateAndTime | read-only | current |
| vcnCrntPMHPESValidity OBJECT-TYPE Indicates the validity of the provided high order path errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.15 | PMValidity | read-only | current |
| vcnCrntPMHPSESValue OBJECT-TYPE The count of high order path severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.16 | Unsigned32 | read-write | current |
| vcnCrntPMHPSESTimeStamp OBJECT-TYPE The date and time stamp of the high order path severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.17 | DateAndTime | read-only | current |
| vcnCrntPMHPSESValidity OBJECT-TYPE Indicates the validity of the provided high order path severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.18 | PMValidity | read-only | current |
| vcnCrntPMHPUASValue OBJECT-TYPE The count of high order path unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.19 | Unsigned32 | read-write | current |
| vcnCrntPMHPUASTimeStamp OBJECT-TYPE The date and time stamp of the high order path unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.20 | DateAndTime | read-only | current |
| vcnCrntPMHPUASValidity OBJECT-TYPE Indicates the validity of the provided high order path unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.21 | PMValidity | read-only | current |
| vcnCrntPMHPEBInitialize OBJECT-TYPE Used to initialize the value of the vcnCrntPMHPEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.22 | InitializeCmd | read-write | current |
| vcnCrntPMHPBBEInitialize OBJECT-TYPE Used to initialize the value of the vcnCrntPMHPBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.23 | InitializeCmd | read-write | current |
| vcnCrntPMHPESInitialize OBJECT-TYPE Used to initialize the value of the vcnCrntPMHPESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.24 | InitializeCmd | read-write | current |
| vcnCrntPMHPSESInitialize OBJECT-TYPE Used to initialize the value of the vcnCrntPMHPSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.25 | InitializeCmd | read-write | current |
| vcnCrntPMHPUASInitialize OBJECT-TYPE Used to initialize the value of the vcnCrntPMHPUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.17.1.26 | InitializeCmd | read-write | current |
| vcnHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the SDH VC-N facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.18 | not-accessible | current | |
| vcnHistPMEntry OBJECT-TYPE The row entry object of the SDH VC-N historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given VC-N facility. | 1.3.6.1.4.1.18070.2.2.1.6.18.1 | not-accessible | current | |
| vcnHistPMTypeIdx OBJECT-TYPE The type of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.1 | VcnType | not-accessible | current |
| vcnHistPMShelfIdx OBJECT-TYPE The number of the shelf of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnHistPMSlotIdx OBJECT-TYPE The number of the slot of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.3 | INTEGER (1..20) | not-accessible | current |
| vcnHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.4 | INTEGER (1..2) | not-accessible | current |
| vcnHistPMIdx OBJECT-TYPE The channel number of the VC-N facility targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.5 | INTEGER (1..64) | not-accessible | current |
| vcnHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.6 | PMIntervalType | not-accessible | current |
| vcnHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.7 | INTEGER (1..96) | not-accessible | current |
| vcnHistPMHPEBValue OBJECT-TYPE The count of high order path errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.8 | Unsigned32 | read-write | current |
| vcnHistPMHPEBTimeStamp OBJECT-TYPE The date and time stamp of the high order path errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.9 | DateAndTime | read-only | current |
| vcnHistPMHPEBValidity OBJECT-TYPE Indicates the validity of the provided high order path errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.10 | PMValidity | read-only | current |
| vcnHistPMHPBBEValue OBJECT-TYPE The count of high order path background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.11 | Unsigned32 | read-write | current |
| vcnHistPMHPBBETimeStamp OBJECT-TYPE The date and time stamp of the high order path background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.12 | DateAndTime | read-only | current |
| vcnHistPMHPBBEValidity OBJECT-TYPE Indicates the validity of the provided high order path background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.13 | PMValidity | read-only | current |
| vcnHistPMHPESValue OBJECT-TYPE The count of high order path errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.14 | Unsigned32 | read-write | current |
| vcnHistPMHPESTimeStamp OBJECT-TYPE The date and time stamp of the high order path errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.15 | DateAndTime | read-only | current |
| vcnHistPMHPESValidity OBJECT-TYPE Indicates the validity of the high order path errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.16 | PMValidity | read-only | current |
| vcnHistPMHPSESValue OBJECT-TYPE The count of high order path severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.17 | Unsigned32 | read-write | current |
| vcnHistPMHPSESTimeStamp OBJECT-TYPE The date and time stamp of the high order path severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.18 | DateAndTime | read-only | current |
| vcnHistPMHPSESValidity OBJECT-TYPE Indicates the validity of the provided high order path severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.19 | PMValidity | read-only | current |
| vcnHistPMHPUASValue OBJECT-TYPE The count of high order path unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.20 | Unsigned32 | read-write | current |
| vcnHistPMHPUASTimeStamp OBJECT-TYPE The date and time stamp of the high order path unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.21 | DateAndTime | read-only | current |
| vcnHistPMHPUASValidity OBJECT-TYPE Indicates the validity of the provided high order path unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.22 | PMValidity | read-only | current |
| vcnHistPMHPEBInitialize OBJECT-TYPE Used to initialize the value of the vcnHistPMHPEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.23 | InitializeCmd | read-write | current |
| vcnHistPMHPBBEInitialize OBJECT-TYPE Used to initialize the value of the vcnHistPMHPBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.24 | InitializeCmd | read-write | current |
| vcnHistPMHPESInitialize OBJECT-TYPE Used to initialize the value of the vcnHistPMHPESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.25 | InitializeCmd | read-write | current |
| vcnHistPMHPSESInitialize OBJECT-TYPE Used to initialize the value of the vcnHistPMHPSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.26 | InitializeCmd | read-write | current |
| vcnHistPMHPUASInitialize OBJECT-TYPE Used to initialize the value of the vcnHistPMHPUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.18.1.27 | InitializeCmd | read-write | current |
| vcnPMThresholdByPortTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on SDH VC-N facilities, that are used in the generation of threshold crossing alerts. The VC-N threshold settings will be the same for all channels on a given STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.19 | not-accessible | current | |
| vcnPMThresholdByPortEntry OBJECT-TYPE The row entry object of the SDH STM-N performance monitoring threshold by port table. Each row of this table contains a set of PM thresholds for a given interval type that applies to all the VC-N channels on an STM-N facility port. | 1.3.6.1.4.1.18070.2.2.1.6.19.1 | not-accessible | current | |
| vcnPMThresholdByPortTypeIdx OBJECT-TYPE The type of the VC-N facility targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.1 | VcnType | not-accessible | current |
| vcnPMThresholdByPortShelfIdx OBJECT-TYPE The shelf number of the VC-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnPMThresholdByPortSlotIdx OBJECT-TYPE The slot number of the VC-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.3 | INTEGER (1..20) | not-accessible | current |
| vcnPMThresholdByPortIdx OBJECT-TYPE The number of the port on the circuit pack of the VC-N facilities targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.4 | INTEGER (1..2) | not-accessible | current |
| vcnPMThresholdByPortIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.5 | PMIntervalType | not-accessible | current |
| vcnPMThresholdByPortHPEBValue OBJECT-TYPE The threshold for the count of high order path errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.6 | Unsigned32 | read-write | current |
| vcnPMThresholdByPortHPBBEValue OBJECT-TYPE The threshold for the count of high order path background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.7 | Unsigned32 | read-write | current |
| vcnPMThresholdByPortHPESValue OBJECT-TYPE The threshold for the count of high order path errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.8 | Unsigned32 | read-write | current |
| vcnPMThresholdByPortHPSESValue OBJECT-TYPE The threshold for the count of high order path severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.9 | Unsigned32 | read-write | current |
| vcnPMThresholdByPortHPUASValue OBJECT-TYPE The threshold for the count of high order path unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.19.1.10 | Unsigned32 | read-write | current |
| geCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the Gigabit Ethernet facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.20 | not-accessible | current | |
| geCrntPMEntry OBJECT-TYPE The row entry object of the Gigabit Ethernet current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.6.20.1 | not-accessible | current | |
| geCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| geCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.2 | INTEGER (1..20) | not-accessible | current |
| geCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.3 | INTEGER (3..12) | not-accessible | current |
| geCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.4 | PMIntervalType | not-accessible | current |
| geCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.5 | FixedX10 | read-only | current |
| geCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.6 | DateAndTime | read-only | current |
| geCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.7 | PMValidity | read-only | current |
| geCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.8 | FixedX10 | read-only | current |
| geCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.9 | DateAndTime | read-only | current |
| geCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.10 | PMValidity | read-only | current |
| geCrntPMTempValue OBJECT-TYPE The temperature measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.11 | INTEGER (-32768..32767) | read-only | current |
| geCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.12 | DateAndTime | read-only | current |
| geCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.13 | PMValidity | read-only | current |
| geCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.14 | FixedX10 | read-only | current |
| geCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.15 | DateAndTime | read-only | current |
| geCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.16 | PMValidity | read-only | current |
| geCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.17 | INTEGER (-32768..32767) | read-only | current |
| geCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.18 | DateAndTime | read-only | current |
| geCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.19 | PMValidity | read-only | current |
| geCrntPMCVValue OBJECT-TYPE The count of Gigabit Ethernet 8B/10B coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.20 | Unsigned32 | read-write | current |
| geCrntPMCVTimeStamp OBJECT-TYPE The date and time stamp of the GE coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.21 | DateAndTime | read-only | current |
| geCrntPMCVValidity OBJECT-TYPE Indicates the validity of the provided GE coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.22 | PMValidity | read-only | current |
| geCrntPMESValue OBJECT-TYPE The count of GE errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.23 | Unsigned32 | read-write | current |
| geCrntPMESTimeStamp OBJECT-TYPE The date and time stamp of the GE errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.24 | DateAndTime | read-only | current |
| geCrntPMESValidity OBJECT-TYPE Indicates the validity of the provided GE errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.25 | PMValidity | read-only | current |
| geCrntPMSESValue OBJECT-TYPE The count of GE severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.26 | Unsigned32 | read-write | current |
| geCrntPMSESTimeStamp OBJECT-TYPE The date and time stamp of the GE severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.27 | DateAndTime | read-only | current |
| geCrntPMSESValidity OBJECT-TYPE Indicates the validity of the provided GE severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.28 | PMValidity | read-only | current |
| geCrntPMTFRCRXValue OBJECT-TYPE The Gigabit Ethernet total received frame count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.29 | Unsigned64 | read-only | current |
| geCrntPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.30 | DateAndTime | read-only | current |
| geCrntPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.31 | PMValidity | read-only | current |
| geCrntPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTFRCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.32 | InitializeCmd | read-write | current |
| geCrntPMTFRCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted frame count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.33 | Unsigned64 | read-only | current |
| geCrntPMTFRCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.34 | DateAndTime | read-only | current |
| geCrntPMTFRCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.35 | PMValidity | read-only | current |
| geCrntPMTFRCTXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTFRCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.36 | InitializeCmd | read-write | current |
| geCrntPMFRDRValue OBJECT-TYPE The count of Gigabit Ethernet discarded frames. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.37 | Unsigned32 | read-write | current |
| geCrntPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the GE discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.38 | DateAndTime | read-only | current |
| geCrntPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided GE discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.39 | PMValidity | read-only | current |
| geCrntPMFCSEValue OBJECT-TYPE The count of Gigabit Ethernet frame checksum errors. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.40 | Unsigned32 | read-write | current |
| geCrntPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the GE frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.41 | DateAndTime | read-only | current |
| geCrntPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided GE frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.42 | PMValidity | read-only | current |
| geCrntPMTBYCRXValue OBJECT-TYPE The Gigabit Ethernet total received byte count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.43 | Unsigned64 | read-only | current |
| geCrntPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.44 | DateAndTime | read-only | current |
| geCrntPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.45 | PMValidity | read-only | current |
| geCrntPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.46 | InitializeCmd | read-write | current |
| geCrntPMTBYCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted byte count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.47 | Unsigned64 | read-only | current |
| geCrntPMTBYCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.48 | DateAndTime | read-only | current |
| geCrntPMTBYCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.49 | PMValidity | read-only | current |
| geCrntPMTBYCTXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTBYCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.50 | InitializeCmd | read-write | current |
| geCrntPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.51 | Unsigned64 | read-only | current |
| geCrntPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.52 | DateAndTime | read-only | current |
| geCrntPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.53 | PMValidity | read-only | current |
| geCrntPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.54 | InitializeCmd | read-write | current |
| geCrntPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.55 | Unsigned64 | read-only | current |
| geCrntPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.56 | DateAndTime | read-only | current |
| geCrntPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.57 | PMValidity | read-only | current |
| geCrntPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.58 | InitializeCmd | read-write | current |
| geCrntPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.59 | Unsigned64 | read-only | current |
| geCrntPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.60 | DateAndTime | read-only | current |
| geCrntPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.61 | PMValidity | read-only | current |
| geCrntPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.62 | InitializeCmd | read-write | current |
| geCrntPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.63 | Unsigned64 | read-only | current |
| geCrntPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.64 | DateAndTime | read-only | current |
| geCrntPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.65 | PMValidity | read-only | current |
| geCrntPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.66 | InitializeCmd | read-write | current |
| geCrntPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.67 | Unsigned64 | read-only | current |
| geCrntPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.68 | DateAndTime | read-only | current |
| geCrntPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.69 | PMValidity | read-only | current |
| geCrntPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.70 | InitializeCmd | read-write | current |
| geCrntPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.71 | Unsigned64 | read-only | current |
| geCrntPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.72 | DateAndTime | read-only | current |
| geCrntPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.73 | PMValidity | read-only | current |
| geCrntPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.74 | InitializeCmd | read-write | current |
| geCrntPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.75 | Unsigned64 | read-only | current |
| geCrntPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.76 | DateAndTime | read-only | current |
| geCrntPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.77 | PMValidity | read-only | current |
| geCrntPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.78 | InitializeCmd | read-write | current |
| geCrntPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.79 | Unsigned64 | read-only | current |
| geCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.80 | DateAndTime | read-only | current |
| geCrntPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.81 | PMValidity | read-only | current |
| geCrntPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.82 | InitializeCmd | read-write | current |
| geCrntPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.83 | Unsigned64 | read-only | current |
| geCrntPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.84 | DateAndTime | read-only | current |
| geCrntPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.85 | PMValidity | read-only | current |
| geCrntPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the geCrntPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.86 | InitializeCmd | read-write | current |
| geCrntPMTPFCRXValue OBJECT-TYPE The Gigabit Ethernet total received pause frame count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.87 | Unsigned64 | read-only | current |
| geCrntPMTPFCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.88 | DateAndTime | read-only | current |
| geCrntPMTPFCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.89 | PMValidity | read-only | current |
| geCrntPMTPFCRXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTPFCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.90 | InitializeCmd | read-write | current |
| geCrntPMTPFCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted pause frame count. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.91 | Unsigned64 | read-only | current |
| geCrntPMTPFCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.92 | DateAndTime | read-only | current |
| geCrntPMTPFCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.93 | PMValidity | read-only | current |
| geCrntPMTPFCTXInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMTPFCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.94 | InitializeCmd | read-write | current |
| geCrntPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.95 | Unsigned32 | read-write | current |
| geCrntPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.96 | DateAndTime | read-only | current |
| geCrntPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.97 | PMValidity | read-only | current |
| geCrntPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.98 | Unsigned32 | read-write | current |
| geCrntPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.99 | DateAndTime | read-only | current |
| geCrntPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.100 | PMValidity | read-only | current |
| geCrntPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.101 | Unsigned32 | read-write | current |
| geCrntPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.102 | DateAndTime | read-only | current |
| geCrntPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.103 | PMValidity | read-only | current |
| geCrntPMJABRValue OBJECT-TYPE The total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.20.1.104 | Unsigned32 | read-write | current |
| geCrntPMJABRTimeStamp OBJECT-TYPE The date and time stamp of the count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.105 | DateAndTime | read-only | current |
| geCrntPMJABRValidity OBJECT-TYPE Indicates the validity of the provided count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.106 | PMValidity | read-only | current |
| geCrntPMCVInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.107 | InitializeCmd | read-write | current |
| geCrntPMESInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.108 | InitializeCmd | read-write | current |
| geCrntPMSESInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.109 | InitializeCmd | read-write | current |
| geCrntPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.110 | InitializeCmd | read-write | current |
| geCrntPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.111 | InitializeCmd | read-write | current |
| geCrntPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.112 | InitializeCmd | read-write | current |
| geCrntPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.113 | InitializeCmd | read-write | current |
| geCrntPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.114 | InitializeCmd | read-write | current |
| geCrntPMJABRInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMJABRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.115 | InitializeCmd | read-write | current |
| geCrntPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.116 | Unsigned32 | read-write | current |
| geCrntPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.117 | DateAndTime | read-only | current |
| geCrntPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.118 | PMValidity | read-only | current |
| geCrntPMUASInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.119 | InitializeCmd | read-write | current |
| geCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.120 | FixedX10 | read-only | current |
| geCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.121 | DateAndTime | read-only | current |
| geCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.122 | PMValidity | read-only | current |
| geCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.123 | InitializeCmd | read-write | current |
| geCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.124 | FixedX10 | read-only | current |
| geCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.125 | DateAndTime | read-only | current |
| geCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.126 | PMValidity | read-only | current |
| geCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.127 | InitializeCmd | read-write | current |
| geCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.128 | FixedX10 | read-only | current |
| geCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.129 | DateAndTime | read-only | current |
| geCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.130 | PMValidity | read-only | current |
| geCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.131 | InitializeCmd | read-write | current |
| geCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.132 | FixedX10 | read-only | current |
| geCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.133 | DateAndTime | read-only | current |
| geCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.134 | PMValidity | read-only | current |
| geCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.135 | InitializeCmd | read-write | current |
| geCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.136 | FixedX10 | read-only | current |
| geCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.137 | DateAndTime | read-only | current |
| geCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.138 | PMValidity | read-only | current |
| geCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.139 | InitializeCmd | read-write | current |
| geCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.140 | FixedX10 | read-only | current |
| geCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.141 | DateAndTime | read-only | current |
| geCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.142 | PMValidity | read-only | current |
| geCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the geCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.20.1.143 | InitializeCmd | read-write | current |
| geHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the Gigabit Ethernet facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.21 | not-accessible | current | |
| geHistPMEntry OBJECT-TYPE The row entry object of the Gigabit Ethernet historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.6.21.1 | not-accessible | current | |
| geHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| geHistPMSlotIdx OBJECT-TYPE The number of the slot within which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.2 | INTEGER (1..20) | not-accessible | current |
| geHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the GE facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.3 | INTEGER (3..12) | not-accessible | current |
| geHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.4 | PMIntervalType | not-accessible | current |
| geHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.5 | INTEGER (1..96) | not-accessible | current |
| geHistPMOPRValue OBJECT-TYPE The optical power received on the input of the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.6 | FixedX10 | read-only | current |
| geHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.7 | DateAndTime | read-only | current |
| geHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.8 | PMValidity | read-only | current |
| geHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.9 | FixedX10 | read-only | current |
| geHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.10 | DateAndTime | read-only | current |
| geHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.11 | PMValidity | read-only | current |
| geHistPMTempValue OBJECT-TYPE The temperature measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.12 | INTEGER (-32768..32767) | read-only | current |
| geHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.13 | DateAndTime | read-only | current |
| geHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.14 | PMValidity | read-only | current |
| geHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.15 | FixedX10 | read-only | current |
| geHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.16 | DateAndTime | read-only | current |
| geHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.17 | PMValidity | read-only | current |
| geHistPMLBCValue OBJECT-TYPE The laser bias current measured on the GE facility port. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.18 | INTEGER (-32768..32767) | read-only | current |
| geHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.19 | DateAndTime | read-only | current |
| geHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.20 | PMValidity | read-only | current |
| geHistPMCVValue OBJECT-TYPE The count of Gigabit Ethernet 8B/10B coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.21 | Unsigned32 | read-write | current |
| geHistPMCVTimeStamp OBJECT-TYPE The date and time stamp of the GE coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.22 | DateAndTime | read-only | current |
| geHistPMCVValidity OBJECT-TYPE Indicates the validity of the provided GE coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.23 | PMValidity | read-only | current |
| geHistPMESValue OBJECT-TYPE The count of GE errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.24 | Unsigned32 | read-write | current |
| geHistPMESTimeStamp OBJECT-TYPE The date and time stamp of the GE errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.25 | DateAndTime | read-only | current |
| geHistPMESValidity OBJECT-TYPE Indicates the validity of the provided GE errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.26 | PMValidity | read-only | current |
| geHistPMSESValue OBJECT-TYPE The count of GE severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.27 | Unsigned32 | read-write | current |
| geHistPMSESTimeStamp OBJECT-TYPE The date and time stamp of the GE severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.28 | DateAndTime | read-only | current |
| geHistPMSESValidity OBJECT-TYPE Indicates the validity of the provided GE severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.29 | PMValidity | read-only | current |
| geHistPMTFRCRXValue OBJECT-TYPE The Gigabit Ethernet total received byte count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.30 | Unsigned64 | read-only | current |
| geHistPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.31 | DateAndTime | read-only | current |
| geHistPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.32 | PMValidity | read-only | current |
| geHistPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.33 | InitializeCmd | read-write | current |
| geHistPMTFRCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted frame count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.34 | Unsigned64 | read-only | current |
| geHistPMTFRCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.35 | DateAndTime | read-only | current |
| geHistPMTFRCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.36 | PMValidity | read-only | current |
| geHistPMTFRCTXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTFRCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.37 | InitializeCmd | read-write | current |
| geHistPMFRDRValue OBJECT-TYPE The count of Gigabit Ethernet discarded frames. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.38 | Unsigned32 | read-write | current |
| geHistPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the GE discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.39 | DateAndTime | read-only | current |
| geHistPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided GE discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.40 | PMValidity | read-only | current |
| geHistPMFCSEValue OBJECT-TYPE The count of Gigabit Ethernet frame checksum errors. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.41 | Unsigned32 | read-write | current |
| geHistPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the GE frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.42 | DateAndTime | read-only | current |
| geHistPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided GE frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.43 | PMValidity | read-only | current |
| geHistPMTBYCRXValue OBJECT-TYPE The Gigabit Ethernet total received byte count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.44 | Unsigned64 | read-only | current |
| geHistPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.45 | DateAndTime | read-only | current |
| geHistPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.46 | PMValidity | read-only | current |
| geHistPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.47 | InitializeCmd | read-write | current |
| geHistPMTBYCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted byte count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.48 | Unsigned64 | read-only | current |
| geHistPMTBYCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.49 | DateAndTime | read-only | current |
| geHistPMTBYCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.50 | PMValidity | read-only | current |
| geHistPMTBYCTXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTBYCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.51 | InitializeCmd | read-write | current |
| geHistPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.52 | Unsigned64 | read-only | current |
| geHistPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.53 | DateAndTime | read-only | current |
| geHistPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.54 | PMValidity | read-only | current |
| geHistPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the geHistPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.55 | InitializeCmd | read-write | current |
| geHistPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.56 | Unsigned64 | read-only | current |
| geHistPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.57 | DateAndTime | read-only | current |
| geHistPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.58 | PMValidity | read-only | current |
| geHistPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the geHistPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.59 | InitializeCmd | read-write | current |
| geHistPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.60 | Unsigned64 | read-only | current |
| geHistPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.61 | DateAndTime | read-only | current |
| geHistPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.62 | PMValidity | read-only | current |
| geHistPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.63 | InitializeCmd | read-write | current |
| geHistPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.64 | Unsigned64 | read-only | current |
| geHistPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.65 | DateAndTime | read-only | current |
| geHistPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.66 | PMValidity | read-only | current |
| geHistPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.67 | InitializeCmd | read-write | current |
| geHistPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.68 | Unsigned64 | read-only | current |
| geHistPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.69 | DateAndTime | read-only | current |
| geHistPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.70 | PMValidity | read-only | current |
| geHistPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.71 | InitializeCmd | read-write | current |
| geHistPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.72 | Unsigned64 | read-only | current |
| geHistPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.73 | DateAndTime | read-only | current |
| geHistPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.74 | PMValidity | read-only | current |
| geHistPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.75 | InitializeCmd | read-write | current |
| geHistPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.76 | Unsigned64 | read-only | current |
| geHistPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.77 | DateAndTime | read-only | current |
| geHistPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.78 | PMValidity | read-only | current |
| geHistPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.79 | InitializeCmd | read-write | current |
| geHistPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.80 | Unsigned64 | read-only | current |
| geHistPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.81 | DateAndTime | read-only | current |
| geHistPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.82 | PMValidity | read-only | current |
| geHistPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.83 | InitializeCmd | read-write | current |
| geHistPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.84 | Unsigned64 | read-only | current |
| geHistPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.85 | DateAndTime | read-only | current |
| geHistPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.86 | PMValidity | read-only | current |
| geHistPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the geHistPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.87 | InitializeCmd | read-write | current |
| geHistPMTPFCRXValue OBJECT-TYPE The Gigabit Ethernet total received pause frame count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.88 | Unsigned64 | read-only | current |
| geHistPMTPFCRXTimeStamp OBJECT-TYPE The date and time stamp of the GE total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.89 | DateAndTime | read-only | current |
| geHistPMTPFCRXValidity OBJECT-TYPE Indicates the validity of the provided GE total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.90 | PMValidity | read-only | current |
| geHistPMTPFCRXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTPFCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.91 | InitializeCmd | read-write | current |
| geHistPMTPFCTXValue OBJECT-TYPE The Gigabit Ethernet total transmitted pause frame count. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.92 | Unsigned64 | read-only | current |
| geHistPMTPFCTXTimeStamp OBJECT-TYPE The date and time stamp of the GE total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.93 | DateAndTime | read-only | current |
| geHistPMTPFCTXValidity OBJECT-TYPE Indicates the validity of the provided GE total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.94 | PMValidity | read-only | current |
| geHistPMTPFCTXInitialize OBJECT-TYPE Used to initialize the value of the geHistPMTPFCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.95 | InitializeCmd | read-write | current |
| geHistPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.96 | Unsigned32 | read-write | current |
| geHistPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.97 | DateAndTime | read-only | current |
| geHistPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.98 | PMValidity | read-only | current |
| geHistPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.99 | Unsigned32 | read-write | current |
| geHistPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.100 | DateAndTime | read-only | current |
| geHistPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.101 | PMValidity | read-only | current |
| geHistPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.102 | Unsigned32 | read-write | current |
| geHistPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.103 | DateAndTime | read-only | current |
| geHistPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.104 | PMValidity | read-only | current |
| geHistPMJABRValue OBJECT-TYPE The total number of frames received that were longer than 14336 9600 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.21.1.105 | Unsigned32 | read-write | current |
| geHistPMJABRTimeStamp OBJECT-TYPE The date and time stamp of the count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.106 | DateAndTime | read-only | current |
| geHistPMJABRValidity OBJECT-TYPE Indicates the validity of the provided count of received jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.107 | PMValidity | read-only | current |
| geHistPMCVInitialize OBJECT-TYPE Used to initialize the value of the geHistPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.108 | InitializeCmd | read-write | current |
| geHistPMESInitialize OBJECT-TYPE Used to initialize the value of the geHistPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.109 | InitializeCmd | read-write | current |
| geHistPMSESInitialize OBJECT-TYPE Used to initialize the value of the geHistPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.110 | InitializeCmd | read-write | current |
| geHistPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the geHistPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.111 | InitializeCmd | read-write | current |
| geHistPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the geHistPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.112 | InitializeCmd | read-write | current |
| geHistPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the geHistPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.113 | InitializeCmd | read-write | current |
| geHistPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.114 | InitializeCmd | read-write | current |
| geHistPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the geHistPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.115 | InitializeCmd | read-write | current |
| geHistPMJABRInitialize OBJECT-TYPE Used to initialize the value of the geHistPMJABRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.116 | InitializeCmd | read-write | current |
| geHistPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the gigabit ethernet protocol. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.117 | Unsigned32 | read-write | current |
| geHistPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.118 | DateAndTime | read-only | current |
| geHistPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.119 | PMValidity | read-only | current |
| geHistPMUASInitialize OBJECT-TYPE Used to initialize the value of the geHistPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.120 | InitializeCmd | read-write | current |
| geHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.121 | FixedX10 | read-only | current |
| geHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.122 | DateAndTime | read-only | current |
| geHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.123 | PMValidity | read-only | current |
| geHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.124 | InitializeCmd | read-write | current |
| geHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.125 | FixedX10 | read-only | current |
| geHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.126 | DateAndTime | read-only | current |
| geHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.127 | PMValidity | read-only | current |
| geHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.128 | InitializeCmd | read-write | current |
| geHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.129 | FixedX10 | read-only | current |
| geHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.130 | DateAndTime | read-only | current |
| geHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.131 | PMValidity | read-only | current |
| geHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.132 | InitializeCmd | read-write | current |
| geHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.133 | FixedX10 | read-only | current |
| geHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.134 | DateAndTime | read-only | current |
| geHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.135 | PMValidity | read-only | current |
| geHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.136 | InitializeCmd | read-write | current |
| geHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.137 | FixedX10 | read-only | current |
| geHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.138 | DateAndTime | read-only | current |
| geHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.139 | PMValidity | read-only | current |
| geHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.140 | InitializeCmd | read-write | current |
| geHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.141 | FixedX10 | read-only | current |
| geHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.142 | DateAndTime | read-only | current |
| geHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.143 | PMValidity | read-only | current |
| geHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the geHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.21.1.144 | InitializeCmd | read-write | current |
| gePMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on Gigabit Ethernet facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.22 | not-accessible | current | |
| gePMThresholdEntry OBJECT-TYPE The row entry object of the Gigabit Ethernet performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual GE facility. | 1.3.6.1.4.1.18070.2.2.1.6.22.1 | not-accessible | current | |
| gePMThresholdShelfIdx OBJECT-TYPE The shelf number on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| gePMThresholdSlotIdx OBJECT-TYPE The slot number on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.2 | INTEGER (1..20) | not-accessible | current |
| gePMThresholdPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the Gigabit Ethernet facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.3 | INTEGER (3..12) | not-accessible | current |
| gePMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.4 | PMIntervalType | not-accessible | current |
| gePMThresholdCVValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet 8B/10B coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.5 | Unsigned32 | read-write | current |
| gePMThresholdESValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.6 | Unsigned32 | read-write | current |
| gePMThresholdSESValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.7 | Unsigned32 | read-write | current |
| gePMThresholdFRDRValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet discarded frames. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.8 | Unsigned32 | read-write | current |
| gePMThresholdFCSEValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet frame check sum errors. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.9 | Unsigned32 | read-write | current |
| gePMThresholdUSIZEValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet undersized frames. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.10 | Unsigned32 | read-write | current |
| gePMThresholdOSIZEValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet oversized frames. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.11 | Unsigned32 | read-write | current |
| gePMThresholdFRGTValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet frame fragments. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.12 | Unsigned32 | read-write | current |
| gePMThresholdJABRValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet jabbers. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.13 | Unsigned32 | read-write | current |
| gePMThresholdUASValue OBJECT-TYPE The threshold for the count of Gigabit Ethernet unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.22.1.14 | Unsigned32 | read-write | current |
| fcCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the Fiber Channel facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.23 | not-accessible | current | |
| fcCrntPMEntry OBJECT-TYPE The row entry object of the Fiber Channel current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Fiber Channel facility. | 1.3.6.1.4.1.18070.2.2.1.6.23.1 | not-accessible | current | |
| fcCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| fcCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| fcCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.3 | INTEGER (3..12) | not-accessible | current |
| fcCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.4 | PMIntervalType | not-accessible | current |
| fcCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.5 | FixedX10 | read-only | current |
| fcCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.6 | DateAndTime | read-only | current |
| fcCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.7 | PMValidity | read-only | current |
| fcCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.8 | FixedX10 | read-only | current |
| fcCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.9 | DateAndTime | read-only | current |
| fcCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.10 | PMValidity | read-only | current |
| fcCrntPMTempValue OBJECT-TYPE The temperature measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.11 | INTEGER (-32768..32767) | read-only | current |
| fcCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.12 | DateAndTime | read-only | current |
| fcCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.13 | PMValidity | read-only | current |
| fcCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.14 | FixedX10 | read-only | current |
| fcCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.15 | DateAndTime | read-only | current |
| fcCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.16 | PMValidity | read-only | current |
| fcCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.17 | INTEGER (-32768..32767) | read-only | current |
| fcCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.18 | DateAndTime | read-only | current |
| fcCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.19 | PMValidity | read-only | current |
| fcCrntPMCVValue OBJECT-TYPE The count of Fiber Channel coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.20 | Unsigned32 | read-write | current |
| fcCrntPMCVTimeStamp OBJECT-TYPE The date and time stamp of the FC coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.21 | DateAndTime | read-only | current |
| fcCrntPMCVValidity OBJECT-TYPE Indicates the validity of the provided FC coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.22 | PMValidity | read-only | current |
| fcCrntPMESValue OBJECT-TYPE The count of FC errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.23 | Unsigned32 | read-write | current |
| fcCrntPMESTimeStamp OBJECT-TYPE The date and time stamp of the FC errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.24 | DateAndTime | read-only | current |
| fcCrntPMESValidity OBJECT-TYPE Indicates the validity of the provided FC errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.25 | PMValidity | read-only | current |
| fcCrntPMSESValue OBJECT-TYPE The count of FC severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.26 | Unsigned32 | read-write | current |
| fcCrntPMSESTimeStamp OBJECT-TYPE The date and time stamp of the FC severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.27 | DateAndTime | read-only | current |
| fcCrntPMSESValidity OBJECT-TYPE Indicates the validity of the provided FC severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.28 | PMValidity | read-only | current |
| fcCrntPMCVInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.29 | InitializeCmd | read-write | current |
| fcCrntPMESInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.30 | InitializeCmd | read-write | current |
| fcCrntPMSESInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.31 | InitializeCmd | read-write | current |
| fcCrntPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.32 | Unsigned32 | read-write | current |
| fcCrntPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.33 | DateAndTime | read-only | current |
| fcCrntPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.34 | PMValidity | read-only | current |
| fcCrntPMUASInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.35 | InitializeCmd | read-write | current |
| fcCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.36 | FixedX10 | read-only | current |
| fcCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.37 | DateAndTime | read-only | current |
| fcCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.38 | PMValidity | read-only | current |
| fcCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.39 | InitializeCmd | read-write | current |
| fcCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.40 | FixedX10 | read-only | current |
| fcCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.41 | DateAndTime | read-only | current |
| fcCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.42 | PMValidity | read-only | current |
| fcCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.43 | InitializeCmd | read-write | current |
| fcCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.44 | FixedX10 | read-only | current |
| fcCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.45 | DateAndTime | read-only | current |
| fcCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.46 | PMValidity | read-only | current |
| fcCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.47 | InitializeCmd | read-write | current |
| fcCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.48 | FixedX10 | read-only | current |
| fcCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.49 | DateAndTime | read-only | current |
| fcCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.50 | PMValidity | read-only | current |
| fcCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.51 | InitializeCmd | read-write | current |
| fcCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.52 | FixedX10 | read-only | current |
| fcCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.53 | DateAndTime | read-only | current |
| fcCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.54 | PMValidity | read-only | current |
| fcCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.55 | InitializeCmd | read-write | current |
| fcCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.56 | FixedX10 | read-only | current |
| fcCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.57 | DateAndTime | read-only | current |
| fcCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.58 | PMValidity | read-only | current |
| fcCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the fcCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.23.1.59 | InitializeCmd | read-write | current |
| fcHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the Fiber Channel facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.24 | not-accessible | current | |
| fcHistPMEntry OBJECT-TYPE The row entry object of the Fiber Channel historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Fiber Channel facility. | 1.3.6.1.4.1.18070.2.2.1.6.24.1 | not-accessible | current | |
| fcHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| fcHistPMSlotIdx OBJECT-TYPE The number of the slot within which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| fcHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the FC facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.3 | INTEGER (3..12) | not-accessible | current |
| fcHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.4 | PMIntervalType | not-accessible | current |
| fcHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.5 | INTEGER (1..96) | not-accessible | current |
| fcHistPMOPRValue OBJECT-TYPE The optical power received on the input of the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.6 | FixedX10 | read-only | current |
| fcHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.7 | DateAndTime | read-only | current |
| fcHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.8 | PMValidity | read-only | current |
| fcHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.9 | FixedX10 | read-only | current |
| fcHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.10 | DateAndTime | read-only | current |
| fcHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.11 | PMValidity | read-only | current |
| fcHistPMTempValue OBJECT-TYPE The temperature measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.12 | INTEGER (-32768..32767) | read-only | current |
| fcHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.13 | DateAndTime | read-only | current |
| fcHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.14 | PMValidity | read-only | current |
| fcHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.15 | FixedX10 | read-only | current |
| fcHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.16 | DateAndTime | read-only | current |
| fcHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.17 | PMValidity | read-only | current |
| fcHistPMLBCValue OBJECT-TYPE The laser bias current measured on the FC facility port. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.18 | INTEGER (-32768..32767) | read-only | current |
| fcHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.19 | DateAndTime | read-only | current |
| fcHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.20 | PMValidity | read-only | current |
| fcHistPMCVValue OBJECT-TYPE The count of Fiber Channel coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.21 | Unsigned32 | read-write | current |
| fcHistPMCVTimeStamp OBJECT-TYPE The date and time stamp of the FC coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.22 | DateAndTime | read-only | current |
| fcHistPMCVValidity OBJECT-TYPE Indicates the validity of the provided FC coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.23 | PMValidity | read-only | current |
| fcHistPMESValue OBJECT-TYPE The count of FC errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.24 | Unsigned32 | read-write | current |
| fcHistPMESTimeStamp OBJECT-TYPE The date and time stamp of the FC errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.25 | DateAndTime | read-only | current |
| fcHistPMESValidity OBJECT-TYPE Indicates the validity of the provided FC errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.26 | PMValidity | read-only | current |
| fcHistPMSESValue OBJECT-TYPE The count of FC severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.27 | Unsigned32 | read-write | current |
| fcHistPMSESTimeStamp OBJECT-TYPE The date and time stamp of the FC severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.28 | DateAndTime | read-only | current |
| fcHistPMSESValidity OBJECT-TYPE Indicates the validity of the provided FC severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.29 | PMValidity | read-only | current |
| fcHistPMCVInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.30 | InitializeCmd | read-write | current |
| fcHistPMESInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.31 | InitializeCmd | read-write | current |
| fcHistPMSESInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.32 | InitializeCmd | read-write | current |
| fcHistPMUASValue OBJECT-TYPE The count of unavailable seconds. This object applies only to transciever ports provisioned for the fiber channel protocol. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.33 | Unsigned32 | read-write | current |
| fcHistPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.34 | DateAndTime | read-only | current |
| fcHistPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.35 | PMValidity | read-only | current |
| fcHistPMUASInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.36 | InitializeCmd | read-write | current |
| fcHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.37 | FixedX10 | read-only | current |
| fcHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.38 | DateAndTime | read-only | current |
| fcHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.39 | PMValidity | read-only | current |
| fcHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.40 | InitializeCmd | read-write | current |
| fcHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.41 | FixedX10 | read-only | current |
| fcHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.42 | DateAndTime | read-only | current |
| fcHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.43 | PMValidity | read-only | current |
| fcHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.44 | InitializeCmd | read-write | current |
| fcHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.45 | FixedX10 | read-only | current |
| fcHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.46 | DateAndTime | read-only | current |
| fcHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.47 | PMValidity | read-only | current |
| fcHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.48 | InitializeCmd | read-write | current |
| fcHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.49 | FixedX10 | read-only | current |
| fcHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.50 | DateAndTime | read-only | current |
| fcHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.51 | PMValidity | read-only | current |
| fcHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.52 | InitializeCmd | read-write | current |
| fcHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.53 | FixedX10 | read-only | current |
| fcHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.54 | DateAndTime | read-only | current |
| fcHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.55 | PMValidity | read-only | current |
| fcHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.56 | InitializeCmd | read-write | current |
| fcHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.57 | FixedX10 | read-only | current |
| fcHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.58 | DateAndTime | read-only | current |
| fcHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.59 | PMValidity | read-only | current |
| fcHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the fcHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.24.1.60 | InitializeCmd | read-write | current |
| fcPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on Fiber Channel facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.25 | not-accessible | current | |
| fcPMThresholdEntry OBJECT-TYPE The row entry object of the Fiber Channel performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual FC facility. | 1.3.6.1.4.1.18070.2.2.1.6.25.1 | not-accessible | current | |
| fcPMThresholdShelfIdx OBJECT-TYPE The shelf number on which the Fiber Channel facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| fcPMThresholdSlotIdx OBJECT-TYPE The slot number on which the Fiber Channel facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| fcPMThresholdPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the Fiber Channel facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.3 | INTEGER (3..12) | not-accessible | current |
| fcPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.4 | PMIntervalType | not-accessible | current |
| fcPMThresholdCVValue OBJECT-TYPE The threshold for the count of Fiber Channel coding violations. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.5 | Unsigned32 | read-write | current |
| fcPMThresholdESValue OBJECT-TYPE The threshold for the count of Fiber Channel errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.6 | Unsigned32 | read-write | current |
| fcPMThresholdSESValue OBJECT-TYPE The threshold for the count of Fiber Channel severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.7 | Unsigned32 | read-write | current |
| fcPMThresholdUASValue OBJECT-TYPE The threshold for the count of Fiber Channel unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.25.1.8 | Unsigned32 | read-write | current |
| ethL1IFCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the Ethernet Layer 1 Interface facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.26 | not-accessible | current | |
| ethL1IFCrntPMEntry OBJECT-TYPE The row entry object of the Ethernet Layer 1 Interface current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given Ethernet Layer 1 Interface facility. | 1.3.6.1.4.1.18070.2.2.1.6.26.1 | not-accessible | current | |
| ethL1IFCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the Ethernet Layer 1 facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ethL1IFCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the Ethernet Layer 1 facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ethL1IFCrntPMPortTypeIdx OBJECT-TYPE The type of Ethernet Layer 1 port targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.3 | PvxL1PortType | not-accessible | current |
| ethL1IFCrntPMPortIdx OBJECT-TYPE The number of the port of the identified type targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.4 | INTEGER (1..24) | not-accessible | current |
| ethL1IFCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.5 | PMIntervalType | not-accessible | current |
| ethL1IFCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.6 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.7 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.8 | PMValidity | read-only | current |
| ethL1IFCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.9 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.10 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.11 | PMValidity | read-only | current |
| ethL1IFCrntPMTempValue OBJECT-TYPE The temperature measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.12 | INTEGER (-32768..32767) | read-only | current |
| ethL1IFCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.13 | DateAndTime | read-only | current |
| ethL1IFCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.14 | PMValidity | read-only | current |
| ethL1IFCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.15 | FixedX10 | read-only | current |
| ethL1IFCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.16 | DateAndTime | read-only | current |
| ethL1IFCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.17 | PMValidity | read-only | current |
| ethL1IFCrntPMSupplyVoltage2Value OBJECT-TYPE A second supply voltage value measured on the Ethernet Layer 1 facility port. This object is available only for XFP-equipped Ethernet Interface ports. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.18 | FixedX10 | read-only | current |
| ethL1IFCrntPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.19 | DateAndTime | read-only | current |
| ethL1IFCrntPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.20 | PMValidity | read-only | current |
| ethL1IFCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.21 | INTEGER (-32768..32767) | read-only | current |
| ethL1IFCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.22 | DateAndTime | read-only | current |
| ethL1IFCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.23 | PMValidity | read-only | current |
| ethL1IFCrntPMCVValue OBJECT-TYPE The count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.24 | Unsigned32 | read-write | current |
| ethL1IFCrntPMCVTimeStamp OBJECT-TYPE The date and time stamp of the coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.25 | DateAndTime | read-only | current |
| ethL1IFCrntPMCVValidity OBJECT-TYPE Indicates the validity of the provided coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.26 | PMValidity | read-only | current |
| ethL1IFCrntPMCVInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.27 | InitializeCmd | read-write | current |
| ethL1IFCrntPMINVBLKValue OBJECT-TYPE The count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.28 | Unsigned32 | read-write | current |
| ethL1IFCrntPMINVBLKTimeStamp OBJECT-TYPE The date and time stamp of the invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.29 | DateAndTime | read-only | current |
| ethL1IFCrntPMINVBLKValidity OBJECT-TYPE Indicates the validity of the provided invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.30 | PMValidity | read-only | current |
| ethL1IFCrntPMINVBLKInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMINVBLKValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.31 | InitializeCmd | read-write | current |
| ethL1IFCrntPMESValue OBJECT-TYPE The count of Ethernet Layer 1 errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.32 | Unsigned32 | read-write | current |
| ethL1IFCrntPMESTimeStamp OBJECT-TYPE The date and time stamp of the Ethernet Layer 1 errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.33 | DateAndTime | read-only | current |
| ethL1IFCrntPMESValidity OBJECT-TYPE Indicates the validity of the provided Ethernet Layer 1 errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.34 | PMValidity | read-only | current |
| ethL1IFCrntPMESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.35 | InitializeCmd | read-write | current |
| ethL1IFCrntPMSESValue OBJECT-TYPE The count of Ethernet Layer 1 severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.36 | Unsigned32 | read-write | current |
| ethL1IFCrntPMSESTimeStamp OBJECT-TYPE The date and time stamp of the Ethernet Layer 1 severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.37 | DateAndTime | read-only | current |
| ethL1IFCrntPMSESValidity OBJECT-TYPE Indicates the validity of the provided Ethernet Layer 1 severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.38 | PMValidity | read-only | current |
| ethL1IFCrntPMSESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.39 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.40 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.41 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.42 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.43 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.44 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.45 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.46 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.47 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.48 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.49 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.50 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.51 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.52 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.53 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.54 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.55 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.56 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.57 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.58 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.59 | InitializeCmd | read-write | current |
| ethL1IFCrntPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.26.1.60 | Unsigned32 | read-write | current |
| ethL1IFCrntPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.61 | DateAndTime | read-only | current |
| ethL1IFCrntPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.62 | PMValidity | read-only | current |
| ethL1IFCrntPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.63 | InitializeCmd | read-write | current |
| ethL1IFCrntPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.26.1.64 | Unsigned32 | read-write | current |
| ethL1IFCrntPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.65 | DateAndTime | read-only | current |
| ethL1IFCrntPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.66 | PMValidity | read-only | current |
| ethL1IFCrntPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.67 | InitializeCmd | read-write | current |
| ethL1IFCrntPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.26.1.68 | Unsigned32 | read-write | current |
| ethL1IFCrntPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.69 | DateAndTime | read-only | current |
| ethL1IFCrntPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.70 | PMValidity | read-only | current |
| ethL1IFCrntPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.71 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTNBERValue OBJECT-TYPE The instantaneous BER of the line port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.72 | DisplayString | read-only | current |
| ethL1IFCrntPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.73 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.74 | PMValidity | read-only | current |
| ethL1IFCrntPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.75 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of the line port. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.76 | DisplayString | read-only | current |
| ethL1IFCrntPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.77 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.78 | PMValidity | read-only | current |
| ethL1IFCrntPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.79 | InitializeCmd | read-write | current |
| ethL1IFCrntPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.26.1.80 | Unsigned64 | read-only | current |
| ethL1IFCrntPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.81 | DateAndTime | read-only | current |
| ethL1IFCrntPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.82 | PMValidity | read-only | current |
| ethL1IFCrntPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.83 | InitializeCmd | read-write | current |
| ethL1IFCrntPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.26.1.84 | Unsigned64 | read-only | current |
| ethL1IFCrntPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.85 | DateAndTime | read-only | current |
| ethL1IFCrntPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.86 | PMValidity | read-only | current |
| ethL1IFCrntPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.87 | InitializeCmd | read-write | current |
| ethL1IFCrntPMUASValue OBJECT-TYPE The count of unavailable seconds. This object is only available on Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.88 | Unsigned32 | read-write | current |
| ethL1IFCrntPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.89 | DateAndTime | read-only | current |
| ethL1IFCrntPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.90 | PMValidity | read-only | current |
| ethL1IFCrntPMUASInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.91 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.92 | Unsigned32 | read-write | current |
| ethL1IFCrntPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.93 | DateAndTime | read-only | current |
| ethL1IFCrntPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.94 | PMValidity | read-only | current |
| ethL1IFCrntPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.95 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.96 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.97 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.98 | PMValidity | read-only | current |
| ethL1IFCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.99 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.100 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.101 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.102 | PMValidity | read-only | current |
| ethL1IFCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.103 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.104 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.105 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.106 | PMValidity | read-only | current |
| ethL1IFCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.107 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.108 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.109 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.110 | PMValidity | read-only | current |
| ethL1IFCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.111 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.112 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.113 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.114 | PMValidity | read-only | current |
| ethL1IFCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.115 | InitializeCmd | read-write | current |
| ethL1IFCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.116 | FixedX10 | read-only | current |
| ethL1IFCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.117 | DateAndTime | read-only | current |
| ethL1IFCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.118 | PMValidity | read-only | current |
| ethL1IFCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.26.1.119 | InitializeCmd | read-write | current |
| ethL1IFHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the Ethernet Layer 1 Interface facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.27 | not-accessible | current | |
| ethL1IFHistPMEntry OBJECT-TYPE The row entry object of the Ethernet Layer 1 Interface historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given Ethernet Layer 1 Interface facility. | 1.3.6.1.4.1.18070.2.2.1.6.27.1 | not-accessible | current | |
| ethL1IFHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the Ethernet Layer 1 facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ethL1IFHistPMSlotIdx OBJECT-TYPE The number of the slot within which the Ethernet Layer 1 facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ethL1IFHistPMPortTypeIdx OBJECT-TYPE The type of Ethernet Layer 1 port targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.3 | PvxL1PortType | not-accessible | current |
| ethL1IFHistPMPortIdx OBJECT-TYPE The number of the port of the identified type targeted for PMs. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.4 | INTEGER (1..24) | not-accessible | current |
| ethL1IFHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.5 | PMIntervalType | not-accessible | current |
| ethL1IFHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.6 | INTEGER (1..96) | not-accessible | current |
| ethL1IFHistPMOPRValue OBJECT-TYPE The optical power received on the input of the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.7 | FixedX10 | read-only | current |
| ethL1IFHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.8 | DateAndTime | read-only | current |
| ethL1IFHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.9 | PMValidity | read-only | current |
| ethL1IFHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.10 | FixedX10 | read-only | current |
| ethL1IFHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.11 | DateAndTime | read-only | current |
| ethL1IFHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.12 | PMValidity | read-only | current |
| ethL1IFHistPMTempValue OBJECT-TYPE The temperature measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.13 | INTEGER (-32768..32767) | read-only | current |
| ethL1IFHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.14 | DateAndTime | read-only | current |
| ethL1IFHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.15 | PMValidity | read-only | current |
| ethL1IFHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.16 | FixedX10 | read-only | current |
| ethL1IFHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.17 | DateAndTime | read-only | current |
| ethL1IFHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.18 | PMValidity | read-only | current |
| ethL1IFHistPMSupplyVoltage2Value OBJECT-TYPE A second supply voltage value measured on the Ethernet Layer 1 facility port. This object is available only for XFP-equipped Ethernet Interface ports. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.19 | FixedX10 | read-only | current |
| ethL1IFHistPMSupplyVoltage2TimeStamp OBJECT-TYPE The date and time stamp of the second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.20 | DateAndTime | read-only | current |
| ethL1IFHistPMSupplyVoltage2Validity OBJECT-TYPE Indicates the validity of the provided second supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.21 | PMValidity | read-only | current |
| ethL1IFHistPMLBCValue OBJECT-TYPE The laser bias current measured on the Ethernet Layer 1 facility port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.22 | INTEGER (-32768..32767) | read-only | current |
| ethL1IFHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.23 | DateAndTime | read-only | current |
| ethL1IFHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.24 | PMValidity | read-only | current |
| ethL1IFHistPMCVValue OBJECT-TYPE The count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.25 | Unsigned32 | read-write | current |
| ethL1IFHistPMCVTimeStamp OBJECT-TYPE The date and time stamp of the coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.26 | DateAndTime | read-only | current |
| ethL1IFHistPMCVValidity OBJECT-TYPE Indicates the validity of the provided coding violations value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.27 | PMValidity | read-only | current |
| ethL1IFHistPMCVInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMCVValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.28 | InitializeCmd | read-write | current |
| ethL1IFHistPMINVBLKValue OBJECT-TYPE The count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.29 | Unsigned32 | read-write | current |
| ethL1IFHistPMINVBLKTimeStamp OBJECT-TYPE The date and time stamp of the invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.30 | DateAndTime | read-only | current |
| ethL1IFHistPMINVBLKValidity OBJECT-TYPE Indicates the validity of the provided invalid blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.31 | PMValidity | read-only | current |
| ethL1IFHistPMINVBLKInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMINVBLKValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.32 | InitializeCmd | read-write | current |
| ethL1IFHistPMESValue OBJECT-TYPE The count of Ethernet Layer 1 errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.33 | Unsigned32 | read-write | current |
| ethL1IFHistPMESTimeStamp OBJECT-TYPE The date and time stamp of the Ethernet Layer 1 errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.34 | DateAndTime | read-only | current |
| ethL1IFHistPMESValidity OBJECT-TYPE Indicates the validity of the provided Ethernet Layer 1 errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.35 | PMValidity | read-only | current |
| ethL1IFHistPMESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.36 | InitializeCmd | read-write | current |
| ethL1IFHistPMSESValue OBJECT-TYPE The count of Ethernet Layer 1 severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.37 | Unsigned32 | read-write | current |
| ethL1IFHistPMSESTimeStamp OBJECT-TYPE The date and time stamp of the Ethernet Layer 1 severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.38 | DateAndTime | read-only | current |
| ethL1IFHistPMSESValidity OBJECT-TYPE Indicates the validity of the provided Ethernet Layer 1 severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.39 | PMValidity | read-only | current |
| ethL1IFHistPMSESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.40 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUEBValue OBJECT-TYPE The count of OTU digital wrapper layer errored blocks. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.41 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUEBTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.42 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUEBValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored blocks value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.43 | PMValidity | read-only | current |
| ethL1IFHistPMOTUEBInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUEBValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.44 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUBBEValue OBJECT-TYPE The count of OTU digital wrapper layer background block errors. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.45 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUBBETimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.46 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUBBEValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer background block errors value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.47 | PMValidity | read-only | current |
| ethL1IFHistPMOTUBBEInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUBBEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.48 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUESValue OBJECT-TYPE The count of OTU digital wrapper layer errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.49 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.50 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.51 | PMValidity | read-only | current |
| ethL1IFHistPMOTUESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.52 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUSESValue OBJECT-TYPE The count of OTU digital wrapper layer severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.53 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUSESTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.54 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUSESValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer severely errored seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.55 | PMValidity | read-only | current |
| ethL1IFHistPMOTUSESInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUSESValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.56 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUOFSValue OBJECT-TYPE The count of OTU digital wrapper layer out-of-frame seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.57 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUOFSTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.58 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUOFSValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer out-of-frame seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.59 | PMValidity | read-only | current |
| ethL1IFHistPMOTUOFSInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUOFSValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.60 | InitializeCmd | read-write | current |
| ethL1IFHistPMNBITCRValue OBJECT-TYPE The count of the number of bits corrected. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.61 | Unsigned32 | read-write | current |
| ethL1IFHistPMNBITCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.62 | DateAndTime | read-only | current |
| ethL1IFHistPMNBITCRValidity OBJECT-TYPE Indicates the validity of the provided number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.63 | PMValidity | read-only | current |
| ethL1IFHistPMNBITCRInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMNBITCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.64 | InitializeCmd | read-write | current |
| ethL1IFHistPMNBYTCRValue OBJECT-TYPE The count of the number of bytes corrected. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.65 | Unsigned32 | read-write | current |
| ethL1IFHistPMNBYTCRTimeStamp OBJECT-TYPE The date and time stamp of the number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.66 | DateAndTime | read-only | current |
| ethL1IFHistPMNBYTCRValidity OBJECT-TYPE Indicates the validity of the provided number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.67 | PMValidity | read-only | current |
| ethL1IFHistPMNBYTCRInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMNBYTCRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.68 | InitializeCmd | read-write | current |
| ethL1IFHistPMUNCRCDWValue OBJECT-TYPE The count of uncorrectable codewords. This object applies only to OC-192 line port provisioned for OTN line mapping. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.69 | Unsigned32 | read-write | current |
| ethL1IFHistPMUNCRCDWTimeStamp OBJECT-TYPE The date and time stamp of the uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.70 | DateAndTime | read-only | current |
| ethL1IFHistPMUNCRCDWValidity OBJECT-TYPE Indicates the validity of the provided uncorrectable codewords value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.71 | PMValidity | read-only | current |
| ethL1IFHistPMUNCRCDWInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMUNCRCDWValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.72 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTNBERValue OBJECT-TYPE The instantaneous BER of the line port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.73 | DisplayString | read-only | current |
| ethL1IFHistPMOTNBERTimeStamp OBJECT-TYPE The date and time stamp of the instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.74 | DateAndTime | read-only | current |
| ethL1IFHistPMOTNBERValidity OBJECT-TYPE Indicates the validity of the provided instantaneous BER. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.75 | PMValidity | read-only | current |
| ethL1IFHistPMOTNBERInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTNBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.76 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTNAVGBERValue OBJECT-TYPE The interval/average BER of the line port. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.77 | DisplayString | read-only | current |
| ethL1IFHistPMOTNAVGBERTimeStamp OBJECT-TYPE The date and time stamp of the interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.78 | DateAndTime | read-only | current |
| ethL1IFHistPMOTNAVGBERValidity OBJECT-TYPE Indicates the validity of the provided interval/average BER. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.79 | PMValidity | read-only | current |
| ethL1IFHistPMOTNAVGBERInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTNAVGBERValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.80 | InitializeCmd | read-write | current |
| ethL1IFHistPMNBITCR64BitValue OBJECT-TYPE The 64-bit count of the number of bits corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.27.1.81 | Unsigned64 | read-only | current |
| ethL1IFHistPMNBITCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.82 | DateAndTime | read-only | current |
| ethL1IFHistPMNBITCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bits corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.83 | PMValidity | read-only | current |
| ethL1IFHistPMNBITCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMNBITCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.84 | InitializeCmd | read-write | current |
| ethL1IFHistPMNBYTCR64BitValue OBJECT-TYPE The 64-bit count of the number of bytes corrected. This object applies only to xGigE line ports provisioned for OTN line mapping with Forward Eror Correction (FEC). | 1.3.6.1.4.1.18070.2.2.1.6.27.1.85 | Unsigned64 | read-only | current |
| ethL1IFHistPMNBYTCR64BitTimeStamp OBJECT-TYPE The date and time stamp of the 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.86 | DateAndTime | read-only | current |
| ethL1IFHistPMNBYTCR64BitValidity OBJECT-TYPE Indicates the validity of the provided 64-bit number of bytes corrected value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.87 | PMValidity | read-only | current |
| ethL1IFHistPMNBYTCR64BitInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMNBYTCR64BitValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.88 | InitializeCmd | read-write | current |
| ethL1IFHistPMUASValue OBJECT-TYPE The count of unavailable seconds. This object is only available on Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.89 | Unsigned32 | read-write | current |
| ethL1IFHistPMUASTimeStamp OBJECT-TYPE The date and time stamp of the unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.90 | DateAndTime | read-only | current |
| ethL1IFHistPMUASValidity OBJECT-TYPE Indicates the validity of the provided unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.91 | PMValidity | read-only | current |
| ethL1IFHistPMUASInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.92 | InitializeCmd | read-write | current |
| ethL1IFHistPMOTUUASValue OBJECT-TYPE The count of OTU digital wrapper layer unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.93 | Unsigned32 | read-write | current |
| ethL1IFHistPMOTUUASTimeStamp OBJECT-TYPE The date and time stamp of the OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.94 | DateAndTime | read-only | current |
| ethL1IFHistPMOTUUASValidity OBJECT-TYPE Indicates the validity of the provided OTU digital wrapper layer unavailable seconds value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.95 | PMValidity | read-only | current |
| ethL1IFHistPMOTUUASInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOTUUASValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.96 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.97 | FixedX10 | read-only | current |
| ethL1IFHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.98 | DateAndTime | read-only | current |
| ethL1IFHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.99 | PMValidity | read-only | current |
| ethL1IFHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.100 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.101 | FixedX10 | read-only | current |
| ethL1IFHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.102 | DateAndTime | read-only | current |
| ethL1IFHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.103 | PMValidity | read-only | current |
| ethL1IFHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.104 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.105 | FixedX10 | read-only | current |
| ethL1IFHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.106 | DateAndTime | read-only | current |
| ethL1IFHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.107 | PMValidity | read-only | current |
| ethL1IFHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.108 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.109 | FixedX10 | read-only | current |
| ethL1IFHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.110 | DateAndTime | read-only | current |
| ethL1IFHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.111 | PMValidity | read-only | current |
| ethL1IFHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.112 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.113 | FixedX10 | read-only | current |
| ethL1IFHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.114 | DateAndTime | read-only | current |
| ethL1IFHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.115 | PMValidity | read-only | current |
| ethL1IFHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.116 | InitializeCmd | read-write | current |
| ethL1IFHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.117 | FixedX10 | read-only | current |
| ethL1IFHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.118 | DateAndTime | read-only | current |
| ethL1IFHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.119 | PMValidity | read-only | current |
| ethL1IFHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the ethL1IFHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.27.1.120 | InitializeCmd | read-write | current |
| ethL1IFPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on Ethernet Layer 1 facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.28 | not-accessible | current | |
| ethL1IFPMThresholdEntry OBJECT-TYPE The row entry object of the Ethernet Layer 1 performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual Ethernet Layer 1 facility. | 1.3.6.1.4.1.18070.2.2.1.6.28.1 | not-accessible | current | |
| ethL1IFPMThresholdShelfIdx OBJECT-TYPE The shelf number on which the Ethernet Layer 1 facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ethL1IFPMThresholdSlotIdx OBJECT-TYPE The slot number on which the Ethernet Layer 1 facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ethL1IFPMThresholdPortTypeIdx OBJECT-TYPE The type of Ethernet Layer 1 port targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.3 | PvxL1PortType | not-accessible | current |
| ethL1IFPMThresholdPortIdx OBJECT-TYPE The number of the port of the identified type targeted for PM thresholds. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.4 | INTEGER (1..24) | not-accessible | current |
| ethL1IFPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. Thresholds are supported for the 15-minute and 1-day PM bins only. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.5 | PMIntervalType | not-accessible | current |
| ethL1IFPMThresholdCVValue OBJECT-TYPE The threshold for the count of 8B/10B coding violations. This object is only available on Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.6 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdINVBLKValue OBJECT-TYPE The threshold for the count of invalid blocks. This object is only available on 10 Gigabit Ethernet ports. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.7 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdESValue OBJECT-TYPE The threshold for the count of errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.8 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdSESValue OBJECT-TYPE The threshold for the count of severely errored seconds. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.9 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUEBValue OBJECT-TYPE The threshold for the count of errored blocks at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.10 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUBBEValue OBJECT-TYPE The threshold for the count of background block errors at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.11 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUESValue OBJECT-TYPE The threshold for the count of errored seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.12 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUSESValue OBJECT-TYPE The threshold for the count of severely errored seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.13 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUOFSValue OBJECT-TYPE The threshold for the count of out-of-frame seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.14 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdUNCRCDWValue OBJECT-TYPE The threshold for the count of uncorrectable codewords. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.15 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdUASValue OBJECT-TYPE The threshold for the count of unavailable seconds. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.16 | Unsigned32 | read-write | current |
| ethL1IFPMThresholdOTUUASValue OBJECT-TYPE The threshold for the count of unavailable seconds at the OTU digital wrapper layer. | 1.3.6.1.4.1.18070.2.2.1.6.28.1.17 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the PacketVX Layer2 interfaces on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.29 | not-accessible | current | |
| pvxL2IFCrntPMEntry OBJECT-TYPE The row entry object of the PacketVX Layer 2 current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given PVX Layer 2 interface facility. | 1.3.6.1.4.1.18070.2.2.1.6.29.1 | not-accessible | current | |
| pvxL2IFCrntPMSwitchIdx OBJECT-TYPE The identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.1 | INTEGER (1..11) | not-accessible | current |
| pvxL2IFCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the shelf number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.2 | INTEGER (0 | 1 | 11 | 21 | 31) | not-accessible | current |
| pvxL2IFCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the slot number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.3 | INTEGER (0 | 1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| pvxL2IFCrntPMPortTypeIdx OBJECT-TYPE The type of PacketVX port on which the Layer 2 Interface facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.4 | PvxPortType | not-accessible | current |
| pvxL2IFCrntPMPortIdx OBJECT-TYPE The number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.5 | INTEGER (1..24) | not-accessible | current |
| pvxL2IFCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.6 | PMIntervalType | not-accessible | current |
| pvxL2IFCrntPMTFRCRXValue OBJECT-TYPE The total received frame count receieved on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.7 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.8 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.9 | PMValidity | read-only | current |
| pvxL2IFCrntPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTFRCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.10 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMTFRCTXValue OBJECT-TYPE The total transmitted frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.11 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTFRCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.12 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTFRCTXValidity OBJECT-TYPE Indicates the validity of the provided total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.13 | PMValidity | read-only | current |
| pvxL2IFCrntPMTFRCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTFRCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.14 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMFRDRValue OBJECT-TYPE The count of discarded frames on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.15 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.16 | DateAndTime | read-only | current |
| pvxL2IFCrntPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.17 | PMValidity | read-only | current |
| pvxL2IFCrntPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.18 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMFCSEValue OBJECT-TYPE The count of frame checksum errors on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.19 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.20 | DateAndTime | read-only | current |
| pvxL2IFCrntPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.21 | PMValidity | read-only | current |
| pvxL2IFCrntPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.22 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMTBYCRXValue OBJECT-TYPE The total received byte count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.23 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.24 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.25 | PMValidity | read-only | current |
| pvxL2IFCrntPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.26 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMTBYCTXValue OBJECT-TYPE The total transmitted byte count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.27 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTBYCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.28 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTBYCTXValidity OBJECT-TYPE Indicates the validity of the provided Ftotal transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.29 | PMValidity | read-only | current |
| pvxL2IFCrntPMTBYCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTBYCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.30 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.31 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.32 | DateAndTime | read-only | current |
| pvxL2IFCrntPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.33 | PMValidity | read-only | current |
| pvxL2IFCrntPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.34 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.35 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.36 | DateAndTime | read-only | current |
| pvxL2IFCrntPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.37 | PMValidity | read-only | current |
| pvxL2IFCrntPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.38 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.39 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.40 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.41 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.42 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.43 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.44 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.45 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.46 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.47 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.48 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.49 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.50 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.51 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.52 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.53 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.54 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.55 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.56 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.57 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.58 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.59 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.60 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.61 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.62 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.63 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.64 | DateAndTime | read-only | current |
| pvxL2IFCrntPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.65 | PMValidity | read-only | current |
| pvxL2IFCrntPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.66 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMTPFCRXValue OBJECT-TYPE The total received pause frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.67 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTPFCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.68 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTPFCRXValidity OBJECT-TYPE Indicates the validity of the provided total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.69 | PMValidity | read-only | current |
| pvxL2IFCrntPMTPFCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTPFCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.70 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMTPFCTXValue OBJECT-TYPE The total transmitted pause frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.71 | Unsigned64 | read-only | current |
| pvxL2IFCrntPMTPFCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.72 | DateAndTime | read-only | current |
| pvxL2IFCrntPMTPFCTXValidity OBJECT-TYPE Indicates the validity of the provided total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.73 | PMValidity | read-only | current |
| pvxL2IFCrntPMTPFCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMTPFCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.74 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.75 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.76 | DateAndTime | read-only | current |
| pvxL2IFCrntPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.77 | PMValidity | read-only | current |
| pvxL2IFCrntPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.78 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.79 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.80 | DateAndTime | read-only | current |
| pvxL2IFCrntPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.81 | PMValidity | read-only | current |
| pvxL2IFCrntPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.82 | InitializeCmd | read-write | current |
| pvxL2IFCrntPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.29.1.83 | Unsigned32 | read-write | current |
| pvxL2IFCrntPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.84 | DateAndTime | read-only | current |
| pvxL2IFCrntPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.85 | PMValidity | read-only | current |
| pvxL2IFCrntPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFCrntPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.29.1.86 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the PacketVX Layer2 interfaces on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.30 | not-accessible | current | |
| pvxL2IFHistPMEntry OBJECT-TYPE The row entry object of the PacketVX Layer 2 historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given PVX Layer 2 interface facility. | 1.3.6.1.4.1.18070.2.2.1.6.30.1 | not-accessible | current | |
| pvxL2IFHistPMSwitchIdx OBJECT-TYPE The identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.1 | INTEGER (1..11) | not-accessible | current |
| pvxL2IFHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the shelf number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.2 | INTEGER (0 | 1 | 11 | 21 | 31) | not-accessible | current |
| pvxL2IFHistPMSlotIdx OBJECT-TYPE The number of the slot within which the PVX Layer2 IF targeted for PMs is provisioned. For LAG entities, the slot number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.3 | INTEGER (0 | 1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| pvxL2IFHistPMPortTypeIdx OBJECT-TYPE The type of PacketVX port on which the Layer 2 Interface facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.4 | PvxPortType | not-accessible | current |
| pvxL2IFHistPMPortIdx OBJECT-TYPE The number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.5 | INTEGER (1..24) | not-accessible | current |
| pvxL2IFHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.6 | PMIntervalType | not-accessible | current |
| pvxL2IFHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.7 | INTEGER (1..96) | not-accessible | current |
| pvxL2IFHistPMTFRCRXValue OBJECT-TYPE The total received frame count receieved on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.8 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTFRCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.9 | DateAndTime | read-only | current |
| pvxL2IFHistPMTFRCRXValidity OBJECT-TYPE Indicates the validity of the provided total received frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.10 | PMValidity | read-only | current |
| pvxL2IFHistPMTFRCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTFRCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.11 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTFRCTXValue OBJECT-TYPE The total transmitted frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.12 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTFRCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.13 | DateAndTime | read-only | current |
| pvxL2IFHistPMTFRCTXValidity OBJECT-TYPE Indicates the validity of the provided total transmitted frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.14 | PMValidity | read-only | current |
| pvxL2IFHistPMTFRCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTFRCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.15 | InitializeCmd | read-write | current |
| pvxL2IFHistPMFRDRValue OBJECT-TYPE The count of discarded frames on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.16 | Unsigned32 | read-write | current |
| pvxL2IFHistPMFRDRTimeStamp OBJECT-TYPE The date and time stamp of the discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.17 | DateAndTime | read-only | current |
| pvxL2IFHistPMFRDRValidity OBJECT-TYPE Indicates the validity of the provided discarded frames value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.18 | PMValidity | read-only | current |
| pvxL2IFHistPMFRDRInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMFRDRValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.19 | InitializeCmd | read-write | current |
| pvxL2IFHistPMFCSEValue OBJECT-TYPE The count of frame checksum errors on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.20 | Unsigned32 | read-write | current |
| pvxL2IFHistPMFCSETimeStamp OBJECT-TYPE The date and time stamp of the frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.21 | DateAndTime | read-only | current |
| pvxL2IFHistPMFCSEValidity OBJECT-TYPE Indicates the validity of the provided frame checksum errors value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.22 | PMValidity | read-only | current |
| pvxL2IFHistPMFCSEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMFCSEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.23 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTBYCRXValue OBJECT-TYPE The total received byte count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.24 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTBYCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.25 | DateAndTime | read-only | current |
| pvxL2IFHistPMTBYCRXValidity OBJECT-TYPE Indicates the validity of the provided total received byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.26 | PMValidity | read-only | current |
| pvxL2IFHistPMTBYCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTBYCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.27 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTBYCTXValue OBJECT-TYPE The total transmitted byte count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.28 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTBYCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.29 | DateAndTime | read-only | current |
| pvxL2IFHistPMTBYCTXValidity OBJECT-TYPE Indicates the validity of the provided Ftotal transmitted byte count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.30 | PMValidity | read-only | current |
| pvxL2IFHistPMTBYCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTBYCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.31 | InitializeCmd | read-write | current |
| pvxL2IFHistPMBCSTValue OBJECT-TYPE The total number of good frames received that were directed to the broadcast address. Note that this does not include multicast frames. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.32 | Unsigned64 | read-only | current |
| pvxL2IFHistPMBCSTTimeStamp OBJECT-TYPE The date and time stamp of the broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.33 | DateAndTime | read-only | current |
| pvxL2IFHistPMBCSTValidity OBJECT-TYPE Indicates the validity of the provided broadcast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.34 | PMValidity | read-only | current |
| pvxL2IFHistPMBCSTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMBCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.35 | InitializeCmd | read-write | current |
| pvxL2IFHistPMMCSTValue OBJECT-TYPE The total number of good frames received that were directed to a multicast address. Note that this number does not include frames directed to the broadcast address. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.36 | Unsigned64 | read-only | current |
| pvxL2IFHistPMMCSTTimeStamp OBJECT-TYPE The date and time stamp of the multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.37 | DateAndTime | read-only | current |
| pvxL2IFHistPMMCSTValidity OBJECT-TYPE Indicates the validity of the provided multicast packets received count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.38 | PMValidity | read-only | current |
| pvxL2IFHistPMMCSTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMMCSTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.39 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE64Value OBJECT-TYPE The total number of 64 byte frames received (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.40 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE64TimeStamp OBJECT-TYPE The date and time stamp of the count of 64-byte packets received. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.41 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE64Validity OBJECT-TYPE Indicates the validity of the provided count of 64-byte packets packets received. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.42 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE64Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE64Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.43 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE65To127Value OBJECT-TYPE The total number of frames received that are 65 to 127 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.44 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE65To127TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.45 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE65To127Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 65 and 127 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.46 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE65To127Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE65To127Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.47 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE128To255Value OBJECT-TYPE The total number of frames received that are 128 to 255 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.48 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE128To255TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.49 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE128To255Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 128 and 255 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.50 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE128To255Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE128To255Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.51 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE256To511Value OBJECT-TYPE The total number of frames received that are 256 to 511 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.52 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE256To511TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.53 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE256To511Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 256 and 511 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.54 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE256To511Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE256To511Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.55 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE512To1023Value OBJECT-TYPE The total number of frames received that are 512 to 1023 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.56 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE512To1023TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.57 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE512To1023Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 512 and 1023 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.58 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE512To1023Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE512To1023Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.59 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZE1024To1518Value OBJECT-TYPE The total number of frames received that are 1024 to 1518 bytes inclusive in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.60 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZE1024To1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.61 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZE1024To1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets between 1024 and 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.62 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZE1024To1518Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZE1024To1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.63 | InitializeCmd | read-write | current |
| pvxL2IFHistPMSIZEOver1518Value OBJECT-TYPE The total number of frames received that are greater than or equal to 1519 bytes in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.64 | Unsigned64 | read-only | current |
| pvxL2IFHistPMSIZEOver1518TimeStamp OBJECT-TYPE The date and time stamp of the count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.65 | DateAndTime | read-only | current |
| pvxL2IFHistPMSIZEOver1518Validity OBJECT-TYPE Indicates the validity of the provided count of packets over 1518 bytes. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.66 | PMValidity | read-only | current |
| pvxL2IFHistPMSIZEOver1518Initialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMSIZEOver1518Value object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.67 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTPFCRXValue OBJECT-TYPE The total received pause frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.68 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTPFCRXTimeStamp OBJECT-TYPE The date and time stamp of the total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.69 | DateAndTime | read-only | current |
| pvxL2IFHistPMTPFCRXValidity OBJECT-TYPE Indicates the validity of the provided total received pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.70 | PMValidity | read-only | current |
| pvxL2IFHistPMTPFCRXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTPFCRXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.71 | InitializeCmd | read-write | current |
| pvxL2IFHistPMTPFCTXValue OBJECT-TYPE The total transmitted pause frame count on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.72 | Unsigned64 | read-only | current |
| pvxL2IFHistPMTPFCTXTimeStamp OBJECT-TYPE The date and time stamp of the total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.73 | DateAndTime | read-only | current |
| pvxL2IFHistPMTPFCTXValidity OBJECT-TYPE Indicates the validity of the provided total transmitted pause frame count value. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.74 | PMValidity | read-only | current |
| pvxL2IFHistPMTPFCTXInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMTPFCTXValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.75 | InitializeCmd | read-write | current |
| pvxL2IFHistPMUSIZEValue OBJECT-TYPE The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.76 | Unsigned32 | read-write | current |
| pvxL2IFHistPMUSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.77 | DateAndTime | read-only | current |
| pvxL2IFHistPMUSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of undersized packets. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.78 | PMValidity | read-only | current |
| pvxL2IFHistPMUSIZEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMUSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.79 | InitializeCmd | read-write | current |
| pvxL2IFHistPMOSIZEValue OBJECT-TYPE The total number of frames received that were longer than 9600 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.80 | Unsigned32 | read-write | current |
| pvxL2IFHistPMOSIZETimeStamp OBJECT-TYPE The date and time stamp of the count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.81 | DateAndTime | read-only | current |
| pvxL2IFHistPMOSIZEValidity OBJECT-TYPE Indicates the validity of the provided count of oversized packets. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.82 | PMValidity | read-only | current |
| pvxL2IFHistPMOSIZEInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMOSIZEValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.83 | InitializeCmd | read-write | current |
| pvxL2IFHistPMFRGTValue OBJECT-TYPE The total number of frames received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.18070.2.2.1.6.30.1.84 | Unsigned32 | read-write | current |
| pvxL2IFHistPMFRGTTimeStamp OBJECT-TYPE The date and time stamp of the count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.85 | DateAndTime | read-only | current |
| pvxL2IFHistPMFRGTValidity OBJECT-TYPE Indicates the validity of the provided count of received packet fragments. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.86 | PMValidity | read-only | current |
| pvxL2IFHistPMFRGTInitialize OBJECT-TYPE Used to initialize the value of the pvxL2IFHistPMFRGTValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.30.1.87 | InitializeCmd | read-write | current |
| pvxL2IFPMThresholdTable OBJECT-TYPE A table of threshold levels for performance monitoring counter values on PVX Layer 2 IF facilities, that are used in the generation of threshold crossing alerts. | 1.3.6.1.4.1.18070.2.2.1.6.31 | not-accessible | current | |
| pvxL2IFPMThresholdEntry OBJECT-TYPE The row entry object of the PacketVX Layer 2 Interface performance monitoring threshold table. Each row of this table contains a set of PM thresholds for a given interval type that applies to an individual PVX Layer 2 IF facility. | 1.3.6.1.4.1.18070.2.2.1.6.31.1 | not-accessible | current | |
| pvxL2IFPMThresholdSwitchIdx OBJECT-TYPE The identifier of the ethernet switch instance on which the Layer 2 Interface facilitiy is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.1 | INTEGER (1..11) | not-accessible | current |
| pvxL2IFPMThresholdShelfIdx OBJECT-TYPE The number of the shelf on which the PVX Layer2 IF targeted for PM thresholds is provisioned. For LAG entities, the shelf number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.2 | INTEGER (0 | 1 | 11 | 21 | 31) | not-accessible | current |
| pvxL2IFPMThresholdSlotIdx OBJECT-TYPE The number of the slot within which the PVX Layer2 IF targeted for PM thresholds is provisioned. For LAG entities, the slot number is 0. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.3 | INTEGER (0 | 1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| pvxL2IFPMThresholdPortTypeIdx OBJECT-TYPE The type of PacketVX port on which the Layer 2 Interface facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.4 | PvxPortType | not-accessible | current |
| pvxL2IFPMThresholdPortIdx OBJECT-TYPE The number of the port of the identified type on which the PVX Layer 2 IF facility targeted for PM thresholds is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.5 | INTEGER (1..24) | not-accessible | current |
| pvxL2IFPMThresholdIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.6 | PMIntervalType | not-accessible | current |
| pvxL2IFPMThresholdFRDRValue OBJECT-TYPE The threshold for the count of discarded frames on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.7 | Unsigned32 | read-write | current |
| pvxL2IFPMThresholdFCSEValue OBJECT-TYPE The threshold for the count of frame checksum errors on the interface. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.8 | Unsigned32 | read-write | current |
| pvxL2IFPMThresholdUSIZEValue OBJECT-TYPE The threshold for the count of undersized frames. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.9 | Unsigned32 | read-write | current |
| pvxL2IFPMThresholdOSIZEValue OBJECT-TYPE The threshold for the count of oversized frames. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.10 | Unsigned32 | read-write | current |
| pvxL2IFPMThresholdFRGTValue OBJECT-TYPE The threshold for the count of fragmented frames. | 1.3.6.1.4.1.18070.2.2.1.6.31.1.11 | Unsigned32 | read-write | current |
| briCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the Bit Rate Independent (BRI) facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.38 | not-accessible | current | |
| briCrntPMEntry OBJECT-TYPE The row entry object of the BRI current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given BRI facility. | 1.3.6.1.4.1.18070.2.2.1.6.38.1 | not-accessible | current | |
| briCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| briCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| briCrntPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.3 | INTEGER (3..12) | not-accessible | current |
| briCrntPMIntervalTypeIdx OBJECT-TYPE The type of BRI bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.4 | PMIntervalType | not-accessible | current |
| briCrntPMOPRValue OBJECT-TYPE The optical power received on the input of the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.5 | FixedX10 | read-only | current |
| briCrntPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.6 | DateAndTime | read-only | current |
| briCrntPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.7 | PMValidity | read-only | current |
| briCrntPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.8 | FixedX10 | read-only | current |
| briCrntPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.9 | DateAndTime | read-only | current |
| briCrntPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.10 | PMValidity | read-only | current |
| briCrntPMTempValue OBJECT-TYPE The temperature measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.11 | INTEGER (-32768..32767) | read-only | current |
| briCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.12 | DateAndTime | read-only | current |
| briCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.13 | PMValidity | read-only | current |
| briCrntPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.14 | FixedX10 | read-only | current |
| briCrntPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.15 | DateAndTime | read-only | current |
| briCrntPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.16 | PMValidity | read-only | current |
| briCrntPMLBCValue OBJECT-TYPE The laser bias current measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.17 | INTEGER (-32768..32767) | read-only | current |
| briCrntPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.18 | DateAndTime | read-only | current |
| briCrntPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.19 | PMValidity | read-only | current |
| briCrntPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.20 | FixedX10 | read-only | current |
| briCrntPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.21 | DateAndTime | read-only | current |
| briCrntPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.22 | PMValidity | read-only | current |
| briCrntPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.23 | InitializeCmd | read-write | current |
| briCrntPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.24 | FixedX10 | read-only | current |
| briCrntPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.25 | DateAndTime | read-only | current |
| briCrntPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.26 | PMValidity | read-only | current |
| briCrntPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.27 | InitializeCmd | read-write | current |
| briCrntPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.28 | FixedX10 | read-only | current |
| briCrntPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.29 | DateAndTime | read-only | current |
| briCrntPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.30 | PMValidity | read-only | current |
| briCrntPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.31 | InitializeCmd | read-write | current |
| briCrntPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.32 | FixedX10 | read-only | current |
| briCrntPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.33 | DateAndTime | read-only | current |
| briCrntPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.34 | PMValidity | read-only | current |
| briCrntPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.35 | InitializeCmd | read-write | current |
| briCrntPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.36 | FixedX10 | read-only | current |
| briCrntPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.37 | DateAndTime | read-only | current |
| briCrntPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.38 | PMValidity | read-only | current |
| briCrntPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.39 | InitializeCmd | read-write | current |
| briCrntPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.40 | FixedX10 | read-only | current |
| briCrntPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.41 | DateAndTime | read-only | current |
| briCrntPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.42 | PMValidity | read-only | current |
| briCrntPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the briCrntPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.38.1.43 | InitializeCmd | read-write | current |
| briHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the Bit Rate Independent (BRI) facilities on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.39 | not-accessible | current | |
| briHistPMEntry OBJECT-TYPE The row entry object of the BRI historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given BRI facility. | 1.3.6.1.4.1.18070.2.2.1.6.39.1 | not-accessible | current | |
| briHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| briHistPMSlotIdx OBJECT-TYPE The number of the slot within which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| briHistPMPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the BRI facility targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.3 | INTEGER (3..12) | not-accessible | current |
| briHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.4 | PMIntervalType | not-accessible | current |
| briHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1 to 96 for the 15-minute historical bins. For the 1-day historical bin, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.5 | INTEGER (1..96) | not-accessible | current |
| briHistPMOPRValue OBJECT-TYPE The optical power received on the input of the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.6 | FixedX10 | read-only | current |
| briHistPMOPRTimeStamp OBJECT-TYPE The date and time stamp of the optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.7 | DateAndTime | read-only | current |
| briHistPMOPRValidity OBJECT-TYPE Indicates the validity of the provided optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.8 | PMValidity | read-only | current |
| briHistPMOPTValue OBJECT-TYPE The optical power transmitted at the output of the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.9 | FixedX10 | read-only | current |
| briHistPMOPTTimeStamp OBJECT-TYPE The date and time stamp of the optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.10 | DateAndTime | read-only | current |
| briHistPMOPTValidity OBJECT-TYPE Indicates the validity of the provided optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.11 | PMValidity | read-only | current |
| briHistPMTempValue OBJECT-TYPE The temperature measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.12 | INTEGER (-32768..32767) | read-only | current |
| briHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.13 | DateAndTime | read-only | current |
| briHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.14 | PMValidity | read-only | current |
| briHistPMSupplyVoltageValue OBJECT-TYPE The supply voltage measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.15 | FixedX10 | read-only | current |
| briHistPMSupplyVoltageTimeStamp OBJECT-TYPE The date and time stamp of the supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.16 | DateAndTime | read-only | current |
| briHistPMSupplyVoltageValidity OBJECT-TYPE Indicates the validity of the provided supply voltage value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.17 | PMValidity | read-only | current |
| briHistPMLBCValue OBJECT-TYPE The laser bias current measured on the BRI facility port. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.18 | INTEGER (-32768..32767) | read-only | current |
| briHistPMLBCTimeStamp OBJECT-TYPE The date and time stamp of the laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.19 | DateAndTime | read-only | current |
| briHistPMLBCValidity OBJECT-TYPE Indicates the validity of the provided laser bias current value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.20 | PMValidity | read-only | current |
| briHistPMOPRMinValue OBJECT-TYPE The minimum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.21 | FixedX10 | read-only | current |
| briHistPMOPRMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.22 | DateAndTime | read-only | current |
| briHistPMOPRMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.23 | PMValidity | read-only | current |
| briHistPMOPRMinInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPRMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.24 | InitializeCmd | read-write | current |
| briHistPMOPRMaxValue OBJECT-TYPE The maximum optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.25 | FixedX10 | read-only | current |
| briHistPMOPRMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.26 | DateAndTime | read-only | current |
| briHistPMOPRMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.27 | PMValidity | read-only | current |
| briHistPMOPRMaxInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPRMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.28 | InitializeCmd | read-write | current |
| briHistPMOPRAvgValue OBJECT-TYPE The average optical power received on the input of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.29 | FixedX10 | read-only | current |
| briHistPMOPRAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.30 | DateAndTime | read-only | current |
| briHistPMOPRAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power received value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.31 | PMValidity | read-only | current |
| briHistPMOPRAvgInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPRAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.32 | InitializeCmd | read-write | current |
| briHistPMOPTMinValue OBJECT-TYPE The minimum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.33 | FixedX10 | read-only | current |
| briHistPMOPTMinTimeStamp OBJECT-TYPE The date and time stamp of the minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.34 | DateAndTime | read-only | current |
| briHistPMOPTMinValidity OBJECT-TYPE Indicates the validity of the provided minimum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.35 | PMValidity | read-only | current |
| briHistPMOPTMinInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPTMinValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.36 | InitializeCmd | read-write | current |
| briHistPMOPTMaxValue OBJECT-TYPE The maximum optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.37 | FixedX10 | read-only | current |
| briHistPMOPTMaxTimeStamp OBJECT-TYPE The date and time stamp of the maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.38 | DateAndTime | read-only | current |
| briHistPMOPTMaxValidity OBJECT-TYPE Indicates the validity of the provided maximum optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.39 | PMValidity | read-only | current |
| briHistPMOPTMaxInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPTMaxValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.40 | InitializeCmd | read-write | current |
| briHistPMOPTAvgValue OBJECT-TYPE The average optical power transmitted at the output of the transceiver. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.41 | FixedX10 | read-only | current |
| briHistPMOPTAvgTimeStamp OBJECT-TYPE The date and time stamp of the average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.42 | DateAndTime | read-only | current |
| briHistPMOPTAvgValidity OBJECT-TYPE Indicates the validity of the provided average optical power transmitted value. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.43 | PMValidity | read-only | current |
| briHistPMOPTAvgInitialize OBJECT-TYPE Used to initialize the value of the briHistPMOPTAvgValue object to 0. | 1.3.6.1.4.1.18070.2.2.1.6.39.1.44 | InitializeCmd | read-write | current |
| cpCrntPMTable OBJECT-TYPE A table of current performance monitoring statistics collected for the circuit packs on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.49 | not-accessible | current | |
| cpCrntPMEntry OBJECT-TYPE The row entry object of the equipment current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given circuit pack. | 1.3.6.1.4.1.18070.2.2.1.6.49.1 | not-accessible | current | |
| cpCrntPMCpTypeIdx OBJECT-TYPE The type of the circuit pack targeted for PM retrieval. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.1 | CpType | not-accessible | current |
| cpCrntPMShelfIdx OBJECT-TYPE The number of the shelf on which the circuit pack targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| cpCrntPMSlotIdx OBJECT-TYPE The number of the slot within which the circuit pack targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.3 | INTEGER (1..20) | not-accessible | current |
| cpCrntPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.4 | PMIntervalType | not-accessible | current |
| cpCrntPMTempValue OBJECT-TYPE The circuit pack temperature. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.5 | INTEGER (-32768..32767) | read-only | current |
| cpCrntPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.6 | DateAndTime | read-only | current |
| cpCrntPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.49.1.7 | PMValidity | read-only | current |
| cpHistPMTable OBJECT-TYPE A table of historical performance monitoring statistics collected for the circuit packs on the NE. | 1.3.6.1.4.1.18070.2.2.1.6.50 | not-accessible | current | |
| cpHistPMEntry OBJECT-TYPE The row entry object of the circuit pack historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given circuit pack. | 1.3.6.1.4.1.18070.2.2.1.6.50.1 | not-accessible | current | |
| cpHistPMCpTypeIdx OBJECT-TYPE The type of the circuit pack targeted for PM retrieval. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.1 | CpType | not-accessible | current |
| cpHistPMShelfIdx OBJECT-TYPE The number of the shelf on which the circuit pack targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| cpHistPMSlotIdx OBJECT-TYPE The number of the slot within which the circuit pack targeted for PMs is provisioned. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.3 | INTEGER (1..20) | not-accessible | current |
| cpHistPMIntervalTypeIdx OBJECT-TYPE The type of PM bin according to interval length. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.4 | PMIntervalType | not-accessible | current |
| cpHistPMIntervalIdx OBJECT-TYPE The specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.5 | INTEGER (1..96) | not-accessible | current |
| cpHistPMTempValue OBJECT-TYPE The circuit pack temperature. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.6 | INTEGER (-32768..32767) | read-only | current |
| cpHistPMTempTimeStamp OBJECT-TYPE The date and time stamp of the temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.7 | DateAndTime | read-only | current |
| cpHistPMTempValidity OBJECT-TYPE Indicates the validity of the provided temperature value. | 1.3.6.1.4.1.18070.2.2.1.6.50.1.8 | PMValidity | read-only | current |
| conditions OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.7 | |||
| notifObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.7.1 | |||
| condDateAndTime OBJECT-TYPE This object is used in Trap messages to indicate the date and time at which the condition or alarm reported in the Trap message occurred. | 1.3.6.1.4.1.18070.2.2.1.7.1.1 | DateAndTime | accessible-for-notify | current |
| condReportType OBJECT-TYPE Indicates if this is a condition (non-alarmed) or an alarm. This object is used solely for reporting the condition report type in Trap messages. | 1.3.6.1.4.1.18070.2.2.1.7.1.2 | CondReportType | accessible-for-notify | current |
| condSeverity OBJECT-TYPE Indicates the severity of the condition or alarm. This object is used solely for reporting the condition severity in Trap messages. | 1.3.6.1.4.1.18070.2.2.1.7.1.3 | CondSeverity | accessible-for-notify | current |
| condServiceAffecting OBJECT-TYPE Indicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected. This object is used solely for reporting whether or not a condition is service affecting in Trap messages. | 1.3.6.1.4.1.18070.2.2.1.7.1.4 | CondServiceAffecting | accessible-for-notify | current |
| condDescription OBJECT-TYPE A textual decription of the condition or alarm. This object is used solely for reporting the condition description in Trap messages. | 1.3.6.1.4.1.18070.2.2.1.7.1.5 | DisplayString | accessible-for-notify | current |
| condObjectType OBJECT-TYPE Identifies the type of managed object against which the condition or alarm is raised. | 1.3.6.1.4.1.18070.2.2.1.7.1.6 | NotifObjectType | accessible-for-notify | current |
| condCodeType OBJECT-TYPE This object value uniquely identifies the type of condition or alarm that is raised. | 1.3.6.1.4.1.18070.2.2.1.7.1.7 | NotifCodeType | accessible-for-notify | current |
| actCondTable OBJECT-TYPE This table lists all active conditions and alarms raised on the system. | 1.3.6.1.4.1.18070.2.2.1.7.2 | not-accessible | current | |
| actCondEntry OBJECT-TYPE Contains identifying and descriptive attributes for a single active condition or alarm raised on the network element. | 1.3.6.1.4.1.18070.2.2.1.7.2.1 | not-accessible | current | |
| actCondNotifIdx OBJECT-TYPE Identifies the type of condition or alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.1 | OBJECT IDENTIFIER | not-accessible | current |
| actCondTableEntryIdx OBJECT-TYPE Identifies the type of resource that is alarmed by pointing to the corresponding table entry object. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.2 | OBJECT IDENTIFIER | not-accessible | current |
| actCondInstanceIdx OBJECT-TYPE Identifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actCondTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.3 | DisplayString (SIZE(1..32)) | not-accessible | current |
| actCondReportType OBJECT-TYPE Indicates if the table entry is a condition (non-alarmed) or an alarm. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.4 | CondReportType | read-only | current |
| actCondDateAndTime OBJECT-TYPE The date and time that the condition or alarm reported in the trap message was raised. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.5 | DateAndTime | read-only | current |
| actCondSeverity OBJECT-TYPE Indicates how severe the condition or alarm is. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.6 | CondSeverity | read-only | current |
| actCondServiceAffecting OBJECT-TYPE Indicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.7 | CondServiceAffecting | read-only | current |
| actCondDescription OBJECT-TYPE A textual decription of the condition or alarm. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.8 | DisplayString | read-only | current |
| actCondObjectType OBJECT-TYPE Identifies the type of managed object against which the condition or alarm is raised. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.9 | NotifObjectType | read-only | current |
| actCondCodeType OBJECT-TYPE This object value uniquely identifies the type of condition or alarm that is raised. | 1.3.6.1.4.1.18070.2.2.1.7.2.1.10 | NotifCodeType | read-only | current |
| actCondSummary OBJECT-TYPE This object summarizes the active alarm/condition status of the network element. The value of the object returned indicates the following status data: - noActiveConditions: there are no active alarms or conditions on the network element - nonAlarmedConditionsActive: there is one or more active conditions on the network element, but none are of alarmable severity - minorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is minor - majorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is major - criticalAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is critical | 1.3.6.1.4.1.18070.2.2.1.7.3 | INTEGER {noActiveConditions(1), nonAlarmedConditionsActive(2), minorAlarmsActive(3), majorAlarmsActive(4), criticalAlarmsActive(5)} | read-only | current |
| actAlarmTable OBJECT-TYPE This table lists all active alarms raised on the system. | 1.3.6.1.4.1.18070.2.2.1.7.4 | not-accessible | current | |
| actAlarmEntry OBJECT-TYPE Contains identifying and descriptive attributes for a single active alarm raised on the system. | 1.3.6.1.4.1.18070.2.2.1.7.4.1 | not-accessible | current | |
| actAlarmNotifIdx OBJECT-TYPE Identifies the type of alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.1 | OBJECT IDENTIFIER | not-accessible | current |
| actAlarmTableEntryIdx OBJECT-TYPE Identifies the type of resource that is alarmed by pointing to the corresponding table entry object. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.2 | OBJECT IDENTIFIER | not-accessible | current |
| actAlarmInstanceIdx OBJECT-TYPE Identifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actAlarmTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.3 | DisplayString (SIZE(1..32)) | not-accessible | current |
| actAlarmReportType OBJECT-TYPE Indicates if the table entry is an alarm. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.4 | CondReportType | read-only | current |
| actAlarmDateAndTime OBJECT-TYPE The date and time that the alarm reported in the trap message was raised. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.5 | DateAndTime | read-only | current |
| actAlarmSeverity OBJECT-TYPE Indicates how severe the alarm is. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.6 | CondSeverity | read-only | current |
| actAlarmServiceAffecting OBJECT-TYPE Indicates if the presence of this active alarm impacts the ability of the equipment to provide service as expected. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.7 | CondServiceAffecting | read-only | current |
| actAlarmDescription OBJECT-TYPE A textual decription of the alarm. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.8 | DisplayString | read-only | current |
| actAlarmObjectType OBJECT-TYPE Identifies the type of managed object against which the alarm is raised. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.9 | NotifObjectType | read-only | current |
| actAlarmCodeType OBJECT-TYPE This object value uniquely identifies the type of alarm that is raised. | 1.3.6.1.4.1.18070.2.2.1.7.4.1.10 | NotifCodeType | read-only | current |
| administration OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.8 | |||
| tl1UserTable OBJECT-TYPE This table contains one row for every provisioned user that can operate the TL1 management interface on the NE. Each row contains a list of attributes that pertain to a provisioned TL1 user. | 1.3.6.1.4.1.18070.2.2.1.8.1 | not-accessible | current | |
| tl1UserEntry OBJECT-TYPE The conceptual row object of the TL1 user table. | 1.3.6.1.4.1.18070.2.2.1.8.1.1 | not-accessible | current | |
| tl1UserIdx OBJECT-TYPE This is the unique user identifier, or UID, that is used for TL1 access. | 1.3.6.1.4.1.18070.2.2.1.8.1.1.1 | DisplayString (SIZE(1..32)) | accessible-for-notify | current |
| tl1IpLockoutAddr OBJECT-TYPE This is an IP address from which TL1 user login attempts have been temporarily disabled due to an excessive number of failed user login attempts. | 1.3.6.1.4.1.18070.2.2.1.8.2 | DisplayString (SIZE(1..15)) | accessible-for-notify | current |
| tl1LogTable OBJECT-TYPE This table lists all the log entries generated by the TL1 interface on the BTI 7000 system. | 1.3.6.1.4.1.18070.2.2.1.8.3 | not-accessible | current | |
| tl1LogEntry OBJECT-TYPE The conceptual row object of the TL1 log table. | 1.3.6.1.4.1.18070.2.2.1.8.3.1 | not-accessible | current | |
| tl1LogIdx OBJECT-TYPE The unique identifier for this log entry. It is the global Log Id of the entry when viewed through the TL1 interface. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.1 | Unsigned32 | not-accessible | current |
| tl1LogSysName OBJECT-TYPE The name of the BTI 7000 system at the time that the log was recorded. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.2 | DisplayString (SIZE(1..20)) | read-only | current |
| tl1LogType OBJECT-TYPE The type of log entry. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.3 | INTEGER {alarm(1), event(2), dbChange(3), security(4), command(5), rtrvcmd(6)} | read-only | current |
| tl1LogTypeSpecificLogNum OBJECT-TYPE The type-specific number for this log. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.4 | Unsigned32 | read-only | current |
| tl1LogMsgCode OBJECT-TYPE The message code that was issued for this log entry. This field is relevant to log entries for TL1 autonomous notifications. For example, the message code may be 'REPT ALM OC48'. A message code is reported for all log entries of type alarm, event and dbChange. For logs of type security or command, the message code is an empty string. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.5 | DisplayString (SIZE(1..32)) | read-only | current |
| tl1LogDateAndTime OBJECT-TYPE The timestamp of the log entry. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.6 | DateAndTime | read-only | current |
| tl1LogMessage OBJECT-TYPE This is the main log entry contents. The log entry is enclosed in double quotations. | 1.3.6.1.4.1.18070.2.2.1.8.3.1.7 | DisplayString | read-only | current |
| latestTl1LogNum OBJECT-TYPE Identifies the value of the tl1LogIdx object for the most recently added entry in the tl1LogTable. | 1.3.6.1.4.1.18070.2.2.1.8.4 | Unsigned32 | read-only | current |
| snmpTrapRcvTable OBJECT-TYPE This table contains one row for every configured SNMP trap receiver. Each row contains a list of attributes that pertain to a provisioned trap receiver. All access to this table, whether for read, write, or create requests are restricted to SNMP requests issued with a valid community string configured with read-write access. | 1.3.6.1.4.1.18070.2.2.1.8.5 | not-accessible | current | |
| snmpTrapRcvEntry OBJECT-TYPE The conceptual row object of the SNMP trap receiver table. | 1.3.6.1.4.1.18070.2.2.1.8.5.1 | not-accessible | current | |
| snmpTrapRcvIdx OBJECT-TYPE This string serves as a unique trap receiver Id and is used to index the table. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.1 | DisplayString (SIZE(1..32)) | read-create | current |
| snmpTrapRcvIPAddr OBJECT-TYPE The IP address of the trap receiver. The setting of this object is mandatory when creating a new row. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.2 | IpAddress | read-create | current |
| snmpTrapRcvPort OBJECT-TYPE The port on the specified IP address of the trap receiver. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.3 | INTEGER (1..65535) | read-create | current |
| snmpTrapRcvNotifType OBJECT-TYPE The type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.4 | INTEGER {trap(1), inform(2)} | read-create | current |
| snmpTrapRcvVersion OBJECT-TYPE The type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c. The setting of this object is mandatory when creating a new row. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.5 | INTEGER {snmpV1(1), snmpV2c(2), snmpV3(3)} | read-create | current |
| snmpTrapRcvCommunity OBJECT-TYPE The community string inserted into the trap messages generated for this trap receiver. The setting of this object is mandatory when creating a new row. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.6 | DisplayString (SIZE(1..20)) | read-create | current |
| snmpTrapRcvTTL OBJECT-TYPE The time-to-live for the trap receiver. When the trap receiver is created or this object is set, this object specifies how long the trap receiver is to be configured. When read, the value returned is the length of time remaining before the trap receiver is automatically deleted. The valid range for this object is 000-00 to 099-99. If this object is set to a value of 000-00, the trap receiver will never auto-delete. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.7 | HoursAndMinutes | read-create | current |
| snmpTrapRcvRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the SNMP trap receiver table. | 1.3.6.1.4.1.18070.2.2.1.8.5.1.100 | RowStatus | read-create | current |
| connections OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.9 | |||
| xcvrXCTable OBJECT-TYPE This table contains one row for every provisioned cross connection between optical transceiver facilities on wavelength translator, regenerator and manager circuit packs. | 1.3.6.1.4.1.18070.2.2.1.9.1 | not-accessible | current | |
| xcvrXCEntry OBJECT-TYPE The conceptual row object of the optical transceiver cross connection table. | 1.3.6.1.4.1.18070.2.2.1.9.1.1 | not-accessible | current | |
| xcvrXCSrcTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the transceiver port that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.1 | XcvrType | not-accessible | current |
| xcvrXCSrcShelfIdx OBJECT-TYPE The number of the shelf of the transceiver port that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrXCSrcSlotIdx OBJECT-TYPE The number of the slot of the transceiver port that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrXCSrcIdx OBJECT-TYPE The number of the port of the transceiver port that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrXCDestTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the transceiver port that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.5 | XcvrType | not-accessible | current |
| xcvrXCDestShelfIdx OBJECT-TYPE The number of the shelf of the transceiver port that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrXCDestSlotIdx OBJECT-TYPE The number of the slot of the transceiver port that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.7 | INTEGER (1..20) | not-accessible | current |
| xcvrXCDestIdx OBJECT-TYPE The number of the port of the transceiver port that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.8 | INTEGER (1..4) | not-accessible | current |
| xcvrXCType OBJECT-TYPE The type of cross connection between the identified source and destination transceiver ports. This is a mandatory object when a row of the transceiver cross connect table is created. Only 1-way and 2-way cross-connections are supported on optical transceiver ports | 1.3.6.1.4.1.18070.2.2.1.9.1.1.9 | XCType | read-create | current |
| xcvrXCRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the transceiver cross connection table, which in turn controls the provisioning and de-provisioning of transceiver cross connections. | 1.3.6.1.4.1.18070.2.2.1.9.1.1.100 | RowStatus | read-create | current |
| vcgXCTable OBJECT-TYPE This table contains one row for every provisioned cross connection between VCGs on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.9.2 | not-accessible | current | |
| vcgXCEntry OBJECT-TYPE The conceptual row object of the VCG cross connection table. | 1.3.6.1.4.1.18070.2.2.1.9.2.1 | not-accessible | current | |
| vcgXCSrcShelfIdx OBJECT-TYPE The number of the shelf of the VCG entity that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcgXCSrcSlotIdx OBJECT-TYPE The number of the slot of the VCG entity that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.2 | INTEGER (1..20) | not-accessible | current |
| vcgXCSrcPortIdx OBJECT-TYPE The number of the port of the VCG entity that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.3 | INTEGER (1..2) | not-accessible | current |
| vcgXCSrcIdx OBJECT-TYPE The number of the VCG within the identified port that serves as the source port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.4 | INTEGER (1..255) | not-accessible | current |
| vcgXCDestShelfIdx OBJECT-TYPE The number of the shelf of the VCG entity that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.5 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcgXCDestSlotIdx OBJECT-TYPE The number of the slot of the VCG entity that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.6 | INTEGER (1..20) | not-accessible | current |
| vcgXCDestPortIdx OBJECT-TYPE The number of the port of the VCG entity that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.7 | INTEGER (1..12) | not-accessible | current |
| vcgXCDestIdx OBJECT-TYPE The number of the VCG within the identified port that serves as the destination port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.8 | INTEGER (1..255) | not-accessible | current |
| vcgXCType OBJECT-TYPE The type of cross connection between the identified source and destination VCG entities. This is a mandatory object when a row of the VCG cross connect table is created. Only 2-way and 2-way protected cross-connections are supported between VCGs. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.9 | XCType | read-create | current |
| vcgXCProtShelfNum OBJECT-TYPE The number of the shelf of the VCG entity that serves as the protection port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.10 | INTEGER (1 | 11 | 21 | 31) | read-create | current |
| vcgXCProtSlotNum OBJECT-TYPE The number of the slot of the VCG entity that serves as the protection port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.11 | INTEGER (1..20) | read-create | current |
| vcgXCProtPortNum OBJECT-TYPE The number of the port of the VCG entity that serves as the protection port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.12 | INTEGER (1..2) | read-create | current |
| vcgXCProtNum OBJECT-TYPE The number of the VCG within the identified port that serves as the protection port for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.13 | INTEGER (1..255) | read-create | current |
| vcgXCRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the VCG cross connection table, which in turn controls the provisioning and de-provisioning of VCG cross connections. | 1.3.6.1.4.1.18070.2.2.1.9.2.1.100 | RowStatus | read-create | current |
| stsnXCTable OBJECT-TYPE This table contains one row for every provisioned cross connection between SONET STS-N facilities on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.9.3 | not-accessible | current | |
| stsnXCEntry OBJECT-TYPE The conceptual row object of the STS-N cross connection table. | 1.3.6.1.4.1.18070.2.2.1.9.3.1 | not-accessible | current | |
| stsnXCStsnTypeIdx OBJECT-TYPE The specific STS-N rate of the cross-connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.1 | StsnType | not-accessible | current |
| stsnXCSrcShelfIdx OBJECT-TYPE The number of the shelf of the STS-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnXCSrcSlotIdx OBJECT-TYPE The number of the slot of the STS-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| stsnXCSrcPortIdx OBJECT-TYPE The number of the port of the STS-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.4 | INTEGER (1..2) | not-accessible | current |
| stsnXCSrcIdx OBJECT-TYPE The number of the STS-N within the identified port that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.5 | INTEGER (1..192) | not-accessible | current |
| stsnXCDestShelfIdx OBJECT-TYPE The number of the shelf of the STS-N facility that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnXCDestSlotIdx OBJECT-TYPE The number of the slot of the STS-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.7 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| stsnXCDestPortIdx OBJECT-TYPE The number of the port of the STS-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.8 | INTEGER (1..12) | not-accessible | current |
| stsnXCDestIdx OBJECT-TYPE The number of the STS-N within the identified port that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.9 | INTEGER (1..192) | not-accessible | current |
| stsnXCType OBJECT-TYPE The type of cross connection between the identified source and destination STS-N facilities. This is a mandatory object when a row of the STS-N cross connect table is created. Only 2-way cross-connections are supported between STS-Ns. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.10 | XCType | read-create | current |
| stsnXCProtTypeNum OBJECT-TYPE The rate of the STS-N facility that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.11 | StsnType | read-create | current |
| stsnXCProtShelfNum OBJECT-TYPE The number of the shelf of the STS-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.12 | INTEGER (1 | 11 | 21 | 31) | read-create | current |
| stsnXCProtSlotNum OBJECT-TYPE The number of the slot of the STS-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.13 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | read-create | current |
| stsnXCProtPortNum OBJECT-TYPE The number of the port of the STS-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.14 | INTEGER (1..2) | read-create | current |
| stsnXCProtNum OBJECT-TYPE The number of the STS-N within the identified port that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.15 | INTEGER (1..192) | read-create | current |
| stsnXCRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the STS-N cross connection table, which in turn controls the provisioning and de-provisioning of STS-N cross connections. | 1.3.6.1.4.1.18070.2.2.1.9.3.1.100 | RowStatus | read-create | current |
| vcnXCTable OBJECT-TYPE This table contains one row for every provisioned cross connection between SDH VC-N facilities on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.9.4 | not-accessible | current | |
| vcnXCEntry OBJECT-TYPE The conceptual row object of the VC-N cross connection table. | 1.3.6.1.4.1.18070.2.2.1.9.4.1 | not-accessible | current | |
| vcnXCVcnTypeIdx OBJECT-TYPE The specific rate of the VC-N cross-connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.1 | VcnType | not-accessible | current |
| vcnXCSrcShelfIdx OBJECT-TYPE The number of the shelf of the VC-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnXCSrcSlotIdx OBJECT-TYPE The number of the slot of the VC-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| vcnXCSrcPortIdx OBJECT-TYPE The number of the port of the VC-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.4 | INTEGER (1..2) | not-accessible | current |
| vcnXCSrcIdx OBJECT-TYPE The number of the VC-N within the identified port that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.5 | INTEGER (1..64) | not-accessible | current |
| vcnXCDestShelfIdx OBJECT-TYPE The number of the shelf of the VC-N facility that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnXCDestSlotIdx OBJECT-TYPE The number of the slot of the VC-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.7 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| vcnXCDestPortIdx OBJECT-TYPE The number of the port of the VC-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.8 | INTEGER (1..12) | not-accessible | current |
| vcnXCDestIdx OBJECT-TYPE The number of the VC-N within the identified port that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.9 | INTEGER (1..64) | not-accessible | current |
| vcnXCType OBJECT-TYPE The type of cross connection between the identified source and destination VC-N facilities. This is a mandatory object when a row of the VC-N cross connect table is created. Only 2-way cross-connections are supported between VC-Ns. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.10 | XCType | read-create | current |
| vcnXCProtTypeNum OBJECT-TYPE The rate of the VC-N facility that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.11 | VcnType | read-create | current |
| vcnXCProtShelfNum OBJECT-TYPE The number of the shelf of the VC-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.12 | INTEGER (1 | 11 | 21 | 31) | read-create | current |
| vcnXCProtSlotNum OBJECT-TYPE The number of the slot of the VC-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.13 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | read-create | current |
| vcnXCProtPortNum OBJECT-TYPE The number of the port of the VC-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.14 | INTEGER (1..2) | read-create | current |
| vcnXCProtNum OBJECT-TYPE The number of the VC-N within the identified port that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.15 | INTEGER (1..64) | read-create | current |
| vcnXCRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the VC-N cross connection table, which in turn controls the provisioning and de-provisioning of VC-N cross connections. | 1.3.6.1.4.1.18070.2.2.1.9.4.1.100 | RowStatus | read-create | current |
| odunXCTable OBJECT-TYPE This table contains one row for every provisioned cross connection between OTN ODU-N facilities on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.9.5 | not-accessible | current | |
| odunXCEntry OBJECT-TYPE The conceptual row object of the ODU-N cross connection table. | 1.3.6.1.4.1.18070.2.2.1.9.5.1 | not-accessible | current | |
| odunXCOdunTypeIdx OBJECT-TYPE The specific rate of the ODU-N cross-connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.1 | OdunType | not-accessible | current |
| odunXCSrcShelfIdx OBJECT-TYPE The number of the shelf of the ODU-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| odunXCSrcSlotIdx OBJECT-TYPE The number of the slot of the ODU-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| odunXCSrcPortIdx OBJECT-TYPE The number of the port of the ODU-N facility that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.4 | INTEGER (1..2) | not-accessible | current |
| odunXCSrcIdx OBJECT-TYPE The number of the ODU-N within the identified port that serves as the source end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.5 | INTEGER (1..4) | not-accessible | current |
| odunXCDestShelfIdx OBJECT-TYPE The number of the shelf of the ODU-N facility that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| odunXCDestSlotIdx OBJECT-TYPE The number of the slot of the ODU-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.7 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| odunXCDestPortIdx OBJECT-TYPE The number of the port of the ODU-N entity that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.8 | INTEGER (1..12) | not-accessible | current |
| odunXCDestIdx OBJECT-TYPE The number of the ODU-N within the identified port that serves as the destination end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.9 | INTEGER (1) | not-accessible | current |
| odunXCType OBJECT-TYPE The type of cross connection between the identified source and destination ODU-N facilities. This is a mandatory object when a row of the ODU-N cross connect table is created. Only 2-way cross-connections are supported between ODU-Ns. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.10 | XCType | read-create | current |
| odunXCProtTypeNum OBJECT-TYPE The rate of the ODU-N facility that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.11 | OdunType | read-create | current |
| odunXCProtShelfNum OBJECT-TYPE The number of the shelf of the ODU-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.12 | INTEGER (1 | 11 | 21 | 31) | read-create | current |
| odunXCProtSlotNum OBJECT-TYPE The number of the slot of the ODU-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.13 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | read-create | current |
| odunXCProtPortNum OBJECT-TYPE The number of the port of the ODU-N entity that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.14 | INTEGER (1..2) | read-create | current |
| odunXCProtNum OBJECT-TYPE The number of the ODU-N within the identified port that serves as the protection end-point for the cross connection. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.15 | INTEGER (1..4) | read-create | current |
| odunXCRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the ODU-N cross connection table, which in turn controls the provisioning and de-provisioning of ODU-N cross connections. | 1.3.6.1.4.1.18070.2.2.1.9.5.1.100 | RowStatus | read-create | current |
| protection OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.10 | |||
| xcvrProtGrpTable OBJECT-TYPE This table contains one row for every provisioned protection group pairing between optical transceiver facilities on the wavelength translator, regenerator and manager cards. | 1.3.6.1.4.1.18070.2.2.1.10.1 | not-accessible | current | |
| xcvrProtGrpEntry OBJECT-TYPE The conceptual row object of the optical transceiver protection group table. | 1.3.6.1.4.1.18070.2.2.1.10.1.1 | not-accessible | current | |
| xcvrProtGrpWorkTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the transceiver port that serves as the working port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.1 | XcvrType | not-accessible | current |
| xcvrProtGrpWorkShelfIdx OBJECT-TYPE The number of the shelf of the transceiver port that serves as the working port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrProtGrpWorkSlotIdx OBJECT-TYPE The number of the slot of the transceiver port that serves as the working port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrProtGrpWorkIdx OBJECT-TYPE The number of the port of the transceiver port that serves as the working port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrProtGrpProtTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the transceiver port that serves as the protection port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.5 | XcvrType | not-accessible | current |
| xcvrProtGrpProtShelfIdx OBJECT-TYPE The number of the shelf of the transceiver port that serves as the protection port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrProtGrpProtSlotIdx OBJECT-TYPE The number of the slot of the transceiver port that serves as the protection port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.7 | INTEGER (1..20) | not-accessible | current |
| xcvrProtGrpProtIdx OBJECT-TYPE The number of the port of the transceiver port that serves as the protection port for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.8 | INTEGER (1..4) | not-accessible | current |
| xcvrProtGrpId OBJECT-TYPE Textual data recorded by the user to describe the provisioned transceiver protection group in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.9 | DisplayString (SIZE(0..32)) | read-create | current |
| xcvrProtGrpRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the transceiver protection group table, which in turn controls provisioning and deprovisioning of optical transceiver protection groups. | 1.3.6.1.4.1.18070.2.2.1.10.1.1.100 | RowStatus | read-create | current |
| ocnProtGrpTable OBJECT-TYPE This table contains one row for every provisioned protection group pairing between SONET OC-N facilities on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.10.2 | not-accessible | current | |
| ocnProtGrpEntry OBJECT-TYPE The conceptual row object of the OC-N facility protection group table. | 1.3.6.1.4.1.18070.2.2.1.10.2.1 | not-accessible | current | |
| ocnProtGrpWorkTypeIdx OBJECT-TYPE The specific rate of the OC-N facility that serves as the working facility for the protection group. Currently, only OCN-N facilities that are OTU-N mapped are supported for protection grouping. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.1 | OcnType | not-accessible | current |
| ocnProtGrpWorkShelfIdx OBJECT-TYPE The number of the shelf of the OC-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnProtGrpWorkSlotIdx OBJECT-TYPE The number of the slot of the OC-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ocnProtGrpWorkPortIdx OBJECT-TYPE The number of the port of the OC-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.4 | INTEGER (1..2) | not-accessible | current |
| ocnProtGrpProtTypeIdx OBJECT-TYPE The specific rate of the OC-N facility that serves as the protection facility for the protection group. Currently, only OC-N facilities that are OTU-N mapped are supported for protection grouping. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.5 | OcnType | not-accessible | current |
| ocnProtGrpProtShelfIdx OBJECT-TYPE The number of the shelf of the OC-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnProtGrpProtSlotIdx OBJECT-TYPE The number of the slot of the OC-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.7 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ocnProtGrpProtPortIdx OBJECT-TYPE The number of the port of the OC-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.8 | INTEGER (1..2) | not-accessible | current |
| ocnProtGrpId OBJECT-TYPE Textual data recorded by the user to describe the provisioned OC-N protection group in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.9 | DisplayString (SIZE(0..32)) | read-create | current |
| ocnProtGrpRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the OC-N protection group table, which in turn controls provisioning and deprovisioning of OC-N facility protection groups. | 1.3.6.1.4.1.18070.2.2.1.10.2.1.100 | RowStatus | read-create | current |
| stmnProtGrpTable OBJECT-TYPE This table contains one row for every provisioned protection group pairing between SDH STM-N facilities on Muxponder circuit packs. | 1.3.6.1.4.1.18070.2.2.1.10.3 | not-accessible | current | |
| stmnProtGrpEntry OBJECT-TYPE The conceptual row object of the STM-N facility protection group table. | 1.3.6.1.4.1.18070.2.2.1.10.3.1 | not-accessible | current | |
| stmnProtGrpWorkTypeIdx OBJECT-TYPE The specific rate of the STM-N facility that serves as the working facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.1 | StmnType | not-accessible | current |
| stmnProtGrpWorkShelfIdx OBJECT-TYPE The number of the shelf of the STM-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnProtGrpWorkSlotIdx OBJECT-TYPE The number of the slot of the STM-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| stmnProtGrpWorkPortIdx OBJECT-TYPE The number of the port of the STM-N facility that serves as the working facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.4 | INTEGER (1..2) | not-accessible | current |
| stmnProtGrpProtTypeIdx OBJECT-TYPE The specific rate of the STM-N facility that serves as the protection facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.5 | StmnType | not-accessible | current |
| stmnProtGrpProtShelfIdx OBJECT-TYPE The number of the shelf of the STM-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.6 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnProtGrpProtSlotIdx OBJECT-TYPE The number of the slot of the STM-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.7 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| stmnProtGrpProtPortIdx OBJECT-TYPE The number of the port of the STM-N facility that serves as the protection facility for the protection group. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.8 | INTEGER (1..2) | not-accessible | current |
| stmnProtGrpId OBJECT-TYPE Textual data recorded by the user to describe the provisioned STM-N protection group in a manner useful to the user. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.9 | DisplayString (SIZE(0..32)) | read-create | current |
| stmnProtGrpRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the STM-N protection group table, which in turn controls provisioning and deprovisioning of STM-N facility protection groups. | 1.3.6.1.4.1.18070.2.2.1.10.3.1.100 | RowStatus | read-create | current |
| operations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11 | |||
| neOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.1 | |||
| dbBackupAndRestore OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.1.1 | |||
| dbBackupAndRestoreCmd OBJECT-TYPE This object is used to activate the steps of a database backup or database restore operation. The description of the DbBackupAndRestoreCmd textual convention explains the usage of this object to perform these operations. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.1 | DbBackupAndRestoreCmd | read-write | current |
| dbBackupAndRestoreType OBJECT-TYPE This object is used to indicate whether a local database, or a remote database is involved in the backup or restore operation that is being activated with the dbBackupAndRestoreCmd object, as explained in the DbBackupAndRestoreType textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.2 | DbBackupAndRestoreType | read-write | current |
| dbBackupAndRestoreAddress OBJECT-TYPE The IP address of an ftp server which the NE database is backed up to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.3 | IpAddress | read-write | current |
| dbBackupAndRestorePath OBJECT-TYPE The directory path on the ftp server where where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.4 | DisplayString (SIZE(1..64)) | read-write | current |
| dbBackupAndRestoreFtpUser OBJECT-TYPE The user identifier to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.5 | DisplayString (SIZE(1..64)) | read-write | current |
| dbBackupAndRestoreFtpPswd OBJECT-TYPE The password to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.6 | DisplayString (SIZE(1..64)) | read-write | current |
| dbBackupAndRestoreCheckAlm OBJECT-TYPE This object is used to indicate whether or not the system is to be checked for active alarms before proceding with a backup or restore operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.7 | INTEGER {yes(1), no(2)} | read-write | current |
| dbBackupAndRestoreCheckSysName OBJECT-TYPE This object is used to indicate whether or not the system name of the NE targeted for a database restore operation against the system name embedded in the database backup file to be restored. If set to yes, the requested action will not be performed if system names do not match. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.8 | INTEGER {yes(1), no(2)} | read-write | current |
| dbBackupAndRestoreInvokeFilename OBJECT-TYPE The name of the database backup file that is to be used in a database restore operation. This object is set along with the dbBackupAndRestoreCmd object when it is set to invokeRestore, as a confirmation that the database that is to be restored is the correct database. In order for the invokeRestore command to proceed, the value set for this object must match the value of the dbBackupAndRestoreFilename object. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.9 | DisplayString (SIZE(1..64)) | read-write | current |
| dbBackupAndRestoreFilename OBJECT-TYPE The name of the database backup file that is present and ready to be restored. The value of this field is valid after the completion of the loadRestore command. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.10 | DisplayString (SIZE(1..64)) | read-only | current |
| dbBackupAndRestoreResult OBJECT-TYPE Indicates if the identified stage of the database backup and restore process has resulted in success or failure. | 1.3.6.1.4.1.18070.2.2.1.11.1.1.11 | INTEGER {success(1), failure(2)} | accessible-for-notify | current |
| swUpgrade OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.1.2 | |||
| swUpgradeCmd OBJECT-TYPE This object is used to activate the steps of a software upgrade procedure on the system. The description of the SwUpgradeCmd textual convention explains the usage of this object to perform these operations. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.1 | SwUpgradeCmd | read-write | current |
| swUpgradeAddress OBJECT-TYPE The IP address of an ftp or sftp server from which the software load files for the upgrade are to be downloaded. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.2 | IpAddress | read-write | current |
| swUpgradePath OBJECT-TYPE The directory path on the upgrade load files ftp or sftp server where the software load files are found. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.3 | DisplayString (SIZE(1..64)) | read-write | current |
| swUpgradeFtpUser OBJECT-TYPE The user identifier to be used on the ftp or sftp server from which the upgrade load is downloaded. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.4 | DisplayString (SIZE(1..64)) | read-write | current |
| swUpgradeFtpPswd OBJECT-TYPE The password to be used on the ftp or sftp server from which the upgrade load is downloaded. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.5 | DisplayString (SIZE(1..64)) | read-write | current |
| swUpgradeInvokeRelNum OBJECT-TYPE The release number of the software upgrade load that is targeted in a software upgrade invoke operation. This object must be set along with the swUpgradeCmd object when it is set to invokeUpgrade or invokeScpUpgrade, as a confirmation that the software load to be used in the upgrade is the correct load. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.6 | DisplayString (SIZE(1..16)) | read-write | current |
| swUpgradeCheckAlm OBJECT-TYPE This object is used to indicate whether or not the system is to be checked for active alarms before proceding with a software upgrade operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the swUpgradeCmd object, the value is defaulted to yes. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.7 | INTEGER {yes(1), no(2)} | read-write | current |
| swUpgradeActiveRelNum OBJECT-TYPE The release number of the software load that is installed on the system and is currently active. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.8 | DisplayString (SIZE(1..16)) | read-only | current |
| swUpgradeInactiveRelNum OBJECT-TYPE The release number of the software load that is installed on the system and is currently inactive. | 1.3.6.1.4.1.18070.2.2.1.11.1.2.9 | DisplayString (SIZE(1..16)) | read-only | current |
| swUpgradeFileTransferType OBJECT-TYPE This object is used to define the file transfer protocol used to retreive the load from a remote server. The default value is ftp | 1.3.6.1.4.1.18070.2.2.1.11.1.2.10 | SwUpgradeFileTransferType | read-write | current |
| shelfInvOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.2 | |||
| slotInvOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.3 | |||
| shelfOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.4 | |||
| cpOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.5 | |||
| cpRestartOpTable OBJECT-TYPE This table contains one row for every provisioned restartable circuit pack on the NE to facilitate the performing of circuit pack restarts. | 1.3.6.1.4.1.18070.2.2.1.11.5.1 | not-accessible | current | |
| cpRestartOpEntry OBJECT-TYPE The conceptual row object of the circuit pack restart operation table. | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1 | not-accessible | current | |
| cpRestartOpTypeIdx OBJECT-TYPE The specific type of circuit pack targeted for the restart operation. | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.1 | CpType | not-accessible | current |
| cpRestartOpShelfIdx OBJECT-TYPE The number of the shelf on which the circuit pack targeted for the restart operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| cpRestartOpSlotIdx OBJECT-TYPE The number of the slot in which the circuit pack targeted for the restart operation is provisioned. For ESI type circuit packs, the slot will be 0. For CCM type circuit packs, the slot can only be 1 or 2. | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.3 | INTEGER (0..20) | not-accessible | current |
| cpRestartOpCmd OBJECT-TYPE Used to perform a circuit pack restart operation as follows. - warmRestart causes a restart of the main processor only; traffic is not affected - coldRestart causes a full circuit pack restart, including data path - powerOn causes a circuit pack that has been powered down due to a high temperature or voltage event to power on. When this object is read, the value noOp is returned. | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.4 | INTEGER {noOp(1), warmRestart(2), coldRestart(3), powerOn(4)} | read-write | current |
| oaOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.6 | |||
| oaOOBRSDOpTable OBJECT-TYPE This table contains one row for every provisioned optical amplifier on the NE that supports the Override Optical Back Reflection Shutdown operation. | 1.3.6.1.4.1.18070.2.2.1.11.6.1 | not-accessible | current | |
| oaOOBRSDOpEntry OBJECT-TYPE The conceptual row object of the optical amplifier override optical back reflection shutdown operation table. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1 | not-accessible | current | |
| oaOOBRSDOpTypeIdx OBJECT-TYPE The specific type of optical amplifier. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.1 | OaType | not-accessible | current |
| oaOOBRSDOpShelfIdx OBJECT-TYPE The number of the shelf on which the optical amplifier targeted for the operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| oaOOBRSDOpSlotIdx OBJECT-TYPE The number of the slot within which the optical amplifier facility targeted for the operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.3 | INTEGER (1..20) | not-accessible | current |
| oaOOBRSDOpIdx OBJECT-TYPE The number of the port on the circuit pack on which the optical amplifier facility has been provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.4 | INTEGER (1) | not-accessible | current |
| oaOOBRSDOpCmd OBJECT-TYPE Used to perform a Override Optical Back Reflection Shutdown operation when this object is set to overrideOBRSD. When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.5 | INTEGER {noOp(1), overrideOBRSD(2)} | read-write | current |
| oaOOBRSDOpTimer OBJECT-TYPE Used to specify the time duration of an override back reflection shutdown operation. It is only valid to set the value of this object in the same set request as for the oaOOBRSDOpCmd object. Despite the indicated value range, the actual supported range is 20 to 600. The value 0 is returned when this object is read, even if an overrideOBRSD operation is in progress. | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.6 | INTEGER (0..600) | read-write | current |
| dataCommsOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.7 | |||
| dataCommsPingTable OBJECT-TYPE This table contains one row for every provisioned circuit pack on the NE from which an IP ping request can be sent. This includes all SCP and OSC type packs. | 1.3.6.1.4.1.18070.2.2.1.11.7.1 | not-accessible | current | |
| dataCommsPingEntry OBJECT-TYPE The conceptual row object of the data comms ping table. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1 | not-accessible | current | |
| dataCommsPingCpTypeIdx OBJECT-TYPE This object is used to indicate the type of circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1 | CpType | not-accessible | current |
| dataCommsPingShelfIdx OBJECT-TYPE This object is used to indicate the shelf number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| dataCommsPingSlotIdx OBJECT-TYPE This object is used to indicate the slot number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.3 | INTEGER (1..20) | not-accessible | current |
| dataCommsPingCmd OBJECT-TYPE This object is used to trigger a ping operation from an OSC or SCP circuit pack. The description of DataCommsPingCmd textual convention explains the usage of this object to perform the ping operation. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.4 | DataCommsPingCmd | read-write | current |
| dataCommsPingAddress OBJECT-TYPE This object is used to indicate the IP Address which is the target of the ping operation to be conducted using the dataCommsPingCmd object. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.5 | IpAddress | read-write | current |
| dataCommsPingNumAttempts OBJECT-TYPE This object is used to indicate how many ping attempts are to be made in the ping operation to be conducted using the dataCommsPingCmd object. The default is 3. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.6 | INTEGER (1..3) | read-write | current |
| dataCommsPingNumSuccesses OBJECT-TYPE This object is used to indicate how many ping trials attempted in the ping operation resulted in a successful ping completion. | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.7 | INTEGER (0..3) | read-only | current |
| pluggableInvOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.8 | |||
| pluggableInvRestartOpTable OBJECT-TYPE This table contains one row for every provisioned restartable pluggable on a circuit pack. | 1.3.6.1.4.1.18070.2.2.1.11.8.1 | not-accessible | current | |
| pluggableInvRestartOpEntry OBJECT-TYPE The conceptual row object of the pluggable restart operation table. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1 | not-accessible | current | |
| pluggableInvRestartOpTypeIdx OBJECT-TYPE The type of small form-factor pluggable inventory item targeted for the restart operation. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.1 | INTEGER {unknown(1), xfp(3)} | not-accessible | current |
| pluggableInvRestartOpShelfIdx OBJECT-TYPE The number of the shelf on which the pluggable inventory item resides targeted for the restart operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| pluggableInvRestartOpSlotIdx OBJECT-TYPE The number of the slot that contains the pluggable inventory item targeted for the restart operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.3 | INTEGER (1..20) | not-accessible | current |
| pluggableInvRestartOpPortIdx OBJECT-TYPE The number of the port on the circuit pack that contains the pluggable inventory item. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.4 | INTEGER (1..28) | not-accessible | current |
| pluggableInvRestartOpCmd OBJECT-TYPE Used to perform a restart operation as follows. - coldRestart causes a pluggable restart When this object is read, the value noOp is returned. | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.5 | INTEGER {noOp(1), coldRestart(2)} | read-write | current |
| xcvrOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.9 | |||
| xcvrLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned optical transceiver on the NE to facilitate the performing of transceiver loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.9.1 | not-accessible | current | |
| xcvrLpbkOpEntry OBJECT-TYPE The conceptual row object of the optical transceiver loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1 | not-accessible | current | |
| xcvrLpbkOpTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.1 | XcvrType | not-accessible | current |
| xcvrLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the transceiver targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the transceiver targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrLpbkOpIdx OBJECT-TYPE The number of the port on the circuit pack on which the optical transceiver facility has been provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a transceiver facility as follows: - oprLpbk: operates a loopback on the transceiver - rlsLpbk: causes a previously invoked loopback to be released - oprTermLpbk: operates a terminal loopback for the transceiver When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.5 | INTEGER {noOp(1), oprLpbk(2), rlsLpbk(3), oprTerminalLpbk(4)} | read-write | current |
| xcvrProtSwOpTable OBJECT-TYPE This table contains one row for every provisioned optical transceiver on the NE configured to be part of a protection group pair to facilitate the performing of transceiver protection switching operations. | 1.3.6.1.4.1.18070.2.2.1.11.9.2 | not-accessible | current | |
| xcvrProtSwOpEntry OBJECT-TYPE The conceptual row object of the optical transceiver protection switching operation table. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1 | not-accessible | current | |
| xcvrProtSwOpTypeIdx OBJECT-TYPE The specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.1 | XcvrType | not-accessible | current |
| xcvrProtSwOpShelfIdx OBJECT-TYPE The number of the shelf of the transceiver targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| xcvrProtSwOpSlotIdx OBJECT-TYPE The number of the slot within which the transceiver targeted for the protection switching operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.3 | INTEGER (1..20) | not-accessible | current |
| xcvrProtSwOpIdx OBJECT-TYPE The number of the port on the circuit pack on which the optical transceiver facility has been provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.4 | INTEGER (1..4) | not-accessible | current |
| xcvrProtSwOpCmd OBJECT-TYPE Used to perform a protection switch on a transceiver facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.5 | ProtSwOpCmd | read-write | current |
| adminOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.10 | |||
| amdOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.11 | |||
| ocnOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.12 | |||
| ocnLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned OC-N facility on the NE to facilitate the performing loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.12.1 | not-accessible | current | |
| ocnLpbkOpEntry OBJECT-TYPE The conceptual row object of the OC-N loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1 | not-accessible | current | |
| ocnLpbkOpTypeIdx OBJECT-TYPE The specific type of OC-N signal which is targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.1 | OcnType | not-accessible | current |
| ocnLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the OC-N facility targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the OC-N facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.3 | INTEGER (1..20) | not-accessible | current |
| ocnLpbkOpPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.4 | INTEGER (1..6) | not-accessible | current |
| ocnLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a OC-N facility as follows: - oprFacilityLpbk: operates an OC-N facility loopback - oprTerminalLpbk: operates an OC-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that the terminal loopback can only be operated on a client OC-N facility. When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.5 | INTEGER {noOp(1), oprFacilityLpbk(2), rlsLpbk(3), oprTerminalLpbk(4)} | read-write | current |
| ocnProtSwOpTable OBJECT-TYPE This table contains one row for every provisioned SONET OC-N facility on the NE configured to be part of a protection group pair to facilitate the performing of OC-N line protection switching operations. | 1.3.6.1.4.1.18070.2.2.1.11.12.2 | not-accessible | current | |
| ocnProtSwOpEntry OBJECT-TYPE The conceptual row object of the SONET OC-N facility protection switching operation table. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1 | not-accessible | current | |
| ocnProtSwOpTypeIdx OBJECT-TYPE The specific rate of OC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.1 | OcnType | not-accessible | current |
| ocnProtSwOpShelfIdx OBJECT-TYPE The number of the shelf of the OC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| ocnProtSwOpSlotIdx OBJECT-TYPE The number of the slot within which the OC-N facility targeted for the protection switching operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| ocnProtSwOpIdx OBJECT-TYPE The number of the port on the circuit pack on which the OC-N facility has been provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.4 | INTEGER (1..2) | not-accessible | current |
| ocnProtSwOpCmd OBJECT-TYPE Used to perform a protection switch on a OC-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.5 | ProtSwOpCmd | read-write | current |
| stsnOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.13 | |||
| stsnProtSwOpTable OBJECT-TYPE This table contains one row for every created SONET STS-N facility on the system which is part of a protection group pairing to facilitate the performing of STS-N protection switching operations. | 1.3.6.1.4.1.18070.2.2.1.11.13.1 | not-accessible | current | |
| stsnProtSwOpEntry OBJECT-TYPE The conceptual row object of the SONET STS-N protection switching operation table. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1 | not-accessible | current | |
| stsnProtSwOpTypeIdx OBJECT-TYPE The specific type of STS-N signal targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.1 | StsnType | not-accessible | current |
| stsnProtSwOpShelfIdx OBJECT-TYPE The number of the shelf of the STS-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stsnProtSwOpSlotIdx OBJECT-TYPE The number of the slot of the STS-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.3 | INTEGER (1..20) | not-accessible | current |
| stsnProtSwOpPortIdx OBJECT-TYPE The number of the port of the STS-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.4 | INTEGER (1..2) | not-accessible | current |
| stsnProtSwOpIdx OBJECT-TYPE The sts channel number of the STS-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.5 | INTEGER (1..192) | not-accessible | current |
| stsnProtSwOpCmd OBJECT-TYPE Used to perform a protection switch on a STS-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.6 | ProtSwOpCmd | read-write | current |
| stmnOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.14 | |||
| stmnLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned STM-N facility on the NE to facilitate the performing of STM-N facility loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.14.1 | not-accessible | current | |
| stmnLpbkOpEntry OBJECT-TYPE The conceptual row object of the STM-N loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1 | not-accessible | current | |
| stmnLpbkOpTypeIdx OBJECT-TYPE The specific type of STM-N signal which is targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.1 | StmnType | not-accessible | current |
| stmnLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the STM-N facility targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the STM-N facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.3 | INTEGER (1..20) | not-accessible | current |
| stmnLpbkOpPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.4 | INTEGER (1..6) | not-accessible | current |
| stmnLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a STM-N facility as follows: - oprFacilityLpbk: operates an STM-N facility loopback - oprTerminalLpbk: operates an STM-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that a terminal loopback can only be operated on a client STM-N facility. When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.5 | INTEGER {noOp(1), oprFacilityLpbk(2), rlsLpbk(3), oprTerminalLpbk(4)} | read-write | current |
| stmnProtSwOpTable OBJECT-TYPE This table contains one row for every provisioned SDH STM-N facility on the NE configured to be part of a protection group pair to facilitate the performing of STM-N line protection switching operations. | 1.3.6.1.4.1.18070.2.2.1.11.14.2 | not-accessible | current | |
| stmnProtSwOpEntry OBJECT-TYPE The conceptual row object of the SDH STM-N facility protection switching operation table. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1 | not-accessible | current | |
| stmnProtSwOpTypeIdx OBJECT-TYPE The specific rate of STM-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.1 | StmnType | not-accessible | current |
| stmnProtSwOpShelfIdx OBJECT-TYPE The number of the shelf of the STM-N faacility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| stmnProtSwOpSlotIdx OBJECT-TYPE The number of the slot within which the STM-N facility targeted for the protection switching operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.3 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| stmnProtSwOpIdx OBJECT-TYPE The number of the port on the circuit pack on which the STM-N facility has been provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.4 | INTEGER (1..2) | not-accessible | current |
| stmnProtSwOpCmd OBJECT-TYPE Used to perform a protection switch on a STM-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.5 | ProtSwOpCmd | read-write | current |
| vcnOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.15 | |||
| vcnProtSwOpTable OBJECT-TYPE This table contains one row for every created SDH VC-N facility on the system which is part of a protection group pairing to facilitate the performing of VC-N protection switching operations. | 1.3.6.1.4.1.18070.2.2.1.11.15.1 | not-accessible | current | |
| vcnProtSwOpEntry OBJECT-TYPE The conceptual row object of the SDH VC-N protection switching operation table. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1 | not-accessible | current | |
| vcnProtSwOpTypeIdx OBJECT-TYPE The specific type of VC-N signal targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.1 | VcnType | not-accessible | current |
| vcnProtSwOpShelfIdx OBJECT-TYPE The number of the shelf of the VC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| vcnProtSwOpSlotIdx OBJECT-TYPE The number of the slot of the VC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.3 | INTEGER (1..20) | not-accessible | current |
| vcnProtSwOpPortIdx OBJECT-TYPE The number of the port of the VC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.4 | INTEGER (1..2) | not-accessible | current |
| vcnProtSwOpIdx OBJECT-TYPE The index number of the VC-N facility targeted for the protection switching operation. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.5 | INTEGER (1..64) | not-accessible | current |
| vcnProtSwOpCmd OBJECT-TYPE Used to perform a protection switch on a VC-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention. | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.6 | ProtSwOpCmd | read-write | current |
| geOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.16 | |||
| geLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned Gigabit Ethernet facility on the NE to facilitate the performing of GE facility loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.16.1 | not-accessible | current | |
| geLpbkOpEntry OBJECT-TYPE The conceptual row object of the Gigabit Ethernet loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1 | not-accessible | current | |
| geLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the Gigabit Ethernet facility targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| geLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the Gigabit Ethernet facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.2 | INTEGER (1..20) | not-accessible | current |
| geLpbkOpPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the Gigabit Ethernet facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.3 | INTEGER (3..12) | not-accessible | current |
| geLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a Gigabit Ethernet facility as follows: - oprFacilityLpbk: operates an GE facility loopback - oprFacilityLpbk: operates an GE terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.4 | INTEGER {noOp(1), oprFacilityLpbk(2), oprTerminalLpbk(3), rlsLpbk(4)} | read-write | current |
| fcOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.17 | |||
| fcLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned Fiber Channel facility on the NE to facilitate the performing of FC facility loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.17.1 | not-accessible | current | |
| fcLpbkOpEntry OBJECT-TYPE The conceptual row object of the Fiber Channel loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1 | not-accessible | current | |
| fcLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the Fiber Channel facility targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| fcLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the Fiber Channel facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| fcLpbkOpPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the Fiber Channel facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.3 | INTEGER (3..12) | not-accessible | current |
| fcLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a Fiber Channel facility as follows: - oprFacilityLpbk: operates an FC facility loopback - oprFacilityLpbk: operates an FC terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.4 | INTEGER {noOp(1), oprFacilityLpbk(2), oprTerminalLpbk(3), rlsLpbk(4)} | read-write | current |
| briOperations OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.11.18 | |||
| briLpbkOpTable OBJECT-TYPE This table contains one row for every provisioned Bit Rate Independent (BRI) facility on the NE to facilitate the performing of BRI facility loopback operations. | 1.3.6.1.4.1.18070.2.2.1.11.18.1 | not-accessible | current | |
| briLpbkOpEntry OBJECT-TYPE The conceptual row object of the BRI loopback operation table. | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1 | not-accessible | current | |
| briLpbkOpShelfIdx OBJECT-TYPE The number of the shelf of the BRI facility targeted for the loopback operation. | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.1 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| briLpbkOpSlotIdx OBJECT-TYPE The number of the slot in which the BRI facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.2 | INTEGER (1 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19) | not-accessible | current |
| briLpbkOpPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the BRI facility targeted for the loopback operation is provisioned. | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.3 | INTEGER (3..12) | not-accessible | current |
| briLpbkOpCmd OBJECT-TYPE Used to perform a loopback operation on a BRI facility as follows: - oprFacilityLpbk: operates a BRI facility loopback - oprFacilityLpbk: operates a BRI terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.4 | INTEGER {noOp(1), oprFacilityLpbk(2), oprTerminalLpbk(3), rlsLpbk(4)} | read-write | current |
| synchronization OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.12 | |||
| cpSynchronizationTable OBJECT-TYPE This table contains one row for every provisioned circuit pack that supports SONET synchronization configuration. | 1.3.6.1.4.1.18070.2.2.1.12.1 | not-accessible | current | |
| cpSynchronizationEntry OBJECT-TYPE The conceptual row object of the circuit pack synchronization table. | 1.3.6.1.4.1.18070.2.2.1.12.1.1 | not-accessible | current | |
| cpSynchronizationTypeIdx OBJECT-TYPE The specific type of circuit pack provisioned. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.1 | CpType | not-accessible | current |
| cpSynchronizationShelfIdx OBJECT-TYPE The number of the shelf on which the circuit pack is provisioned. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.2 | INTEGER (1 | 11 | 21 | 31) | not-accessible | current |
| cpSynchronizationSlotIdx OBJECT-TYPE The number of the slot in which the circuit pack is provisioned. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.3 | INTEGER (1..20) | not-accessible | current |
| cpSynchronizationTimingMode OBJECT-TYPE The timing mode used for SONET synchronization on the pack. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.4 | INTEGER {internal(1), line(2)} | read-write | current |
| cpSynchronizationPrimRefSrcPortNum OBJECT-TYPE The port number of the SONET facility that serves as the primary timing reference source. When the value is 0, the primary reference is not configured. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.5 | INTEGER (0..4) | read-write | current |
| cpSynchronizationPrimRefProtStatus OBJECT-TYPE The protection status of the primary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.6 | ProtectionStatusType | read-only | current |
| cpSynchronizationPrimProtStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported protection status of the primary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.7 | OperStatQlfr | read-only | current |
| cpSynchronizationSecRefSrcPortNum OBJECT-TYPE The port number of the SONET facility that serves as the secondary timing reference source. When the value is 0, the secondary reference is not configured. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.8 | INTEGER (0..4) | read-write | current |
| cpSynchronizationSecRefProtStatus OBJECT-TYPE The protection status of the secondary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.9 | ProtectionStatusType | read-only | current |
| cpSynchronizationSecProtStatQlfr OBJECT-TYPE A textual list of qualifiers of the reported protection status of the secondary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.10 | OperStatQlfr | read-only | current |
| cpSynchronizationPrimRefBasicSSM OBJECT-TYPE Used to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.11 | INTEGER {yes(1), no(2)} | read-write | current |
| cpSynchronizationSecRefBasicSSM OBJECT-TYPE Used to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.12 | INTEGER {yes(1), no(2)} | read-write | current |
| cpSynchronizationSwEvtType OBJECT-TYPE Indicates the type of timing reference switching event that has occurred on the circuit pack. | 1.3.6.1.4.1.18070.2.2.1.12.1.1.13 | SyncSwEvtType | accessible-for-notify | current |
| topology OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.13 | |||
| networkNeighborTable OBJECT-TYPE This table is used to store information on the network neighbors of the local network element. Each row contains information on a specific network neighbor. | 1.3.6.1.4.1.18070.2.2.1.13.1 | not-accessible | current | |
| networkNeighborEntry OBJECT-TYPE The conceptual row object of the network neighbor table. | 1.3.6.1.4.1.18070.2.2.1.13.1.1 | not-accessible | current | |
| networkNeighborIdx OBJECT-TYPE A textual identifier of the network neighbor. | 1.3.6.1.4.1.18070.2.2.1.13.1.1.1 | DisplayString (SIZE(1..32)) | not-accessible | current |
| networkNeighborIPAddr OBJECT-TYPE The primary IP Address of the network neighbor. | 1.3.6.1.4.1.18070.2.2.1.13.1.1.2 | IpAddress | read-create | current |
| networkNeighborRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the network neighbor table. | 1.3.6.1.4.1.18070.2.2.1.13.1.1.3 | RowStatus | read-create | current |
| ospfGeneralTable OBJECT-TYPE This table contains all of general OSPF parameters for the network element. The group can be created and deleted but only one entry can exist in the table. | 1.3.6.1.4.1.18070.2.2.1.13.2 | not-accessible | current | |
| ospfGeneralGroupEntry OBJECT-TYPE The list entry for the OSPF General Group parameters. | 1.3.6.1.4.1.18070.2.2.1.13.2.1 | not-accessible | current | |
| ospfIdx OBJECT-TYPE An index used to identify the OSPF instance in order to alow for creation and deletion to allow compatibility with TL1 and CLI interfaces. Note the value is always 1. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.1 | INTEGER (1) | not-accessible | current |
| ospfRouterId OBJECT-TYPE A 32-bit integer uniquely identifying the router. By convention, to ensure uniqueness, this should default to the value of one of the router's IP interface addresses. This object is persistent. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.2 | IpAddress | read-create | current |
| ospfAdminStat OBJECT-TYPE The administrative status of OSPF in the router. The value 'enabled' denotes that the OSPF Process is active on at least one interface; 'disabled' disables it on all interfaces. This object is persistent. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.3 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ospfVersionNumber OBJECT-TYPE The current version number of the OSPF protocol is 2. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.4 | INTEGER {version2(2)} | read-only | current |
| ospfAreaBdrRtrStatus OBJECT-TYPE A flag to note whether this router is an Area Border Router. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.5 | TruthValue | read-only | current |
| ospfRouteRedist OBJECT-TYPE Indicates the extent of route redistribution. Static - static routes, Connected - routes connected to the node. DefOrig - default routes from adjacent nodes. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.6 | INTEGER {none(1), static(2), connected(3), staticAndConnected(4), defOrig(5), defOrigAndStatic(6), defOrigAndConnected(7), all(8)} | read-create | current |
| ospfAreaId OBJECT-TYPE The area ID associated with this OSPF item. Note that although the area ID has the format of an IP Address it is not actually an IP address. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.7 | IpAddress | read-create | current |
| ospfRowStatus OBJECT-TYPE Used to control the addition and deletion of the ospf General Group parameters. | 1.3.6.1.4.1.18070.2.2.1.13.2.1.8 | RowStatus | read-create | current |
| ospfIfTable OBJECT-TYPE The OSPF Interface Table describes the interfaces from the viewpoint of OSPF. | 1.3.6.1.4.1.18070.2.2.1.13.3 | not-accessible | current | |
| ospfIfEntry OBJECT-TYPE The OSPF interface entry describes one interface from the viewpoint of OSPF. Information in this table is persistent and when this object is written the entity is saved to non-volatile storage. | 1.3.6.1.4.1.18070.2.2.1.13.3.1 | not-accessible | current | |
| ospfIfSwitchId OBJECT-TYPE The number of the switch id on which the OSPF interface exists. Set to zero if the switchId a switch Id is not applicable for identification of the OSPF interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.1 | INTEGER (0..11) | accessible-for-notify | current |
| ospfIfShelfIdx OBJECT-TYPE The number of the shelf on which the OSPF interface exists. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.2 | INTEGER (1 | 11 | 21 | 31) | accessible-for-notify | current |
| ospfIfSlotIdx OBJECT-TYPE The number of the slot within the shelf corresponding to the OSPF interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.3 | INTEGER (0..6) | accessible-for-notify | current |
| ospfIfType OBJECT-TYPE The type of the interface corresponding to the OSPF interface. Set to zero if the ospfIfType is not applicable for identification of the OSPF interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.4 | PvxPortType | accessible-for-notify | current |
| ospfIfIdx OBJECT-TYPE The number of the interface within the slot corresponding to the OSPF interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.5 | INTEGER (0..255) | accessible-for-notify | current |
| ospfIfSubIdx OBJECT-TYPE The number of the sub-interface that the OSFP Interface corresponds to. Set to zero if the ospfIfSubIdx is not applicable for identification of the OSPF interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.6 | INTEGER (0..255) | accessible-for-notify | current |
| ospfIfAreaId OBJECT-TYPE A 32-bit integer uniquely identifying the area to which the interface connects. Area ID 0.0.0.0 is used for the OSPF backbone. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.7 | AreaID | read-only | current |
| ospfIfAdminStat OBJECT-TYPE The OSPF interface's administrative status. The value formed on the interface, and the interface will be advertised as an internal route to some area. The value 'disabled' denotes that the interface is external to OSPF. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.8 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| ospfIfRtrPriority OBJECT-TYPE The priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their Router ID as a tie breaker. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.9 | INTEGER (0..255) | read-create | current |
| ospfIfTransitDelay OBJECT-TYPE The estimated number of seconds it takes to transmit a link state update packet over this interface. Note that the minimal value SHOULD be 1 second. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.10 | INTEGER (0..3600) | read-create | current |
| ospfIfRetransInterval OBJECT-TYPE The number of seconds between link state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and Link State request packets. Note that minimal value SHOULD be 1 second. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.11 | INTEGER (0..3600) | read-create | current |
| ospfIfHelloInterval OBJECT-TYPE The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.12 | INTEGER (1..65535) | read-create | current |
| ospfIfRtrDeadInterval OBJECT-TYPE The number of seconds that a router's Hello packets have not been seen before its neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.13 | INTEGER (0..2147483647) | read-create | current |
| ospfIfMetricValue OBJECT-TYPE A metric used to identify the 'cost' associated with using this interface. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.14 | INTEGER (0..65535) | read-create | current |
| ospfIfStatus OBJECT-TYPE This object permits management of the table by facilitating actions such as row creation, construction, and destruction. The value of this object has no effect on whether other objects in this conceptual row can be modified. | 1.3.6.1.4.1.18070.2.2.1.13.3.1.15 | RowStatus | read-create | current |
| ospfLsdbTable OBJECT-TYPE The OSPF Process's link state database (LSDB). The LSDB contains the link state advertisements from throughout the areas that the device is attached to. | 1.3.6.1.4.1.18070.2.2.1.13.4 | not-accessible | current | |
| ospfLsdbEntry OBJECT-TYPE A single link state advertisement. | 1.3.6.1.4.1.18070.2.2.1.13.4.1 | not-accessible | current | |
| ospfLsdbAreaId OBJECT-TYPE The 32-bit identifier of the area from which the LSA was received. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.1 | AreaID | read-only | current |
| ospfLsdbType OBJECT-TYPE The type of the link state advertisement. Each link state type has a separate advertisement format | 1.3.6.1.4.1.18070.2.2.1.13.4.1.2 | INTEGER {routerLink(1), networkLink(2), summaryLink(3), asSummaryLink(4), asExternalLink(5), multicastLink(6), nssaExternalLink(7), areaOpaqueLink(10)} | read-only | current |
| ospfLsdbLsid OBJECT-TYPE The Link State ID is an LS Type Specific field containing either a Router ID or an IP address; it identifies the piece of the routing domain that is being described by the advertisement. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.3 | IpAddress | read-only | current |
| ospfLsdbRouterId OBJECT-TYPE The 32-bit number that uniquely identifies the originating router in the Autonomous System. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.4 | IpAddress | read-only | current |
| ospfLsdbSequence OBJECT-TYPE The sequence number field is a signed 32-bit integer. It starts with the value '80000001'h, or -'7FFFFFFF'h, and increments until '7FFFFFFF'h. Thus, a typical sequence number will be very negative. It is used to detect old and duplicate Link State Advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number, the more recent the advertisement. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.5 | Integer32 | read-only | current |
| ospfLsdbAge OBJECT-TYPE This field is the age of the link state advertisement in seconds. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.6 | Integer32 | read-only | current |
| ospfLsdbChecksum OBJECT-TYPE This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connectionless datagrams; it is commonly referred to as the Fletcher checksum. | 1.3.6.1.4.1.18070.2.2.1.13.4.1.7 | Integer32 | read-only | current |
| ospfNbrTable OBJECT-TYPE A table describing all non-virtual neighbors in the locality of the OSPF router. | 1.3.6.1.4.1.18070.2.2.1.13.5 | not-accessible | current | |
| ospfNbrEntry OBJECT-TYPE The information regarding a single neighbor. Information in this table is persistent and when this object is written the entity SHOULD save the change to non-volatile storage. | 1.3.6.1.4.1.18070.2.2.1.13.5.1 | not-accessible | current | |
| ospfNbrIpAddr OBJECT-TYPE The IP address this neighbor is using in its IP source address. Note that, on addressless links, this will not be 0.0.0.0 but the address of another of the neighbor's interfaces. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.1 | IpAddress | read-only | current |
| ospfNbrAddressLessIndex OBJECT-TYPE On an interface having an IP address, zero. On addressless interfaces, the corresponding value of ifIndex in the Internet Standard MIB. On row creation, this can be derived from the instance. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.2 | Integer32 (0..2147483647) | read-only | current |
| ospfNbrRtrId OBJECT-TYPE A 32-bit integer (represented as a type IpAddress) uniquely identifying the neighboring router in the Autonomous System. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.3 | IpAddress | read-only | current |
| ospfNbrOptions OBJECT-TYPE A bit mask corresponding to the neighbor's options field. Bit 0, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric. Bit 1, if set, indicates that the associated area accepts and operates on external information; if zero, it is a stub area. Bit 2, if set, indicates that the system is capable of routing IP multicast datagrams, that is that it implements the multicast extensions to OSPF. Bit 3, if set, indicates that the associated area is an NSSA. These areas are capable of carrying type-7 external advertisements, which are translated into type-5 external advertisements at NSSA borders. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.4 | Integer32 | read-only | current |
| ospfNbrPriority OBJECT-TYPE The priority of this neighbor in the designated router election algorithm. The value 0 signifies that the neighbor is not eligible to become the designated router on this particular network. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.5 | DesignatedRouterPriority | read-only | current |
| ospfNbrState OBJECT-TYPE The state of the relationship with this neighbor. | 1.3.6.1.4.1.18070.2.2.1.13.5.1.6 | INTEGER {down(1), attempt(2), init(3), twoWay(4), exchangeStart(5), exchange(6), loading(7), full(8)} | read-only | current |
| pvxObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.14 | |||
| pvxBridge OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.14.1 | |||
| pvxL2IntfTable OBJECT-TYPE This table contains one row for every provisioned Ethernet facility on the system. Each row contains a list of attributes that pertain to the facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3 | not-accessible | current | |
| pvxL2IntfEntry OBJECT-TYPE The conceptual row object of the ethIntfTable table. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1 | not-accessible | current | |
| pvxL2IntfSwitchIdx OBJECT-TYPE The number of the switch id of the provisioned ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.1 | INTEGER (1..11) | accessible-for-notify | current |
| pvxL2IntfShelfIdx OBJECT-TYPE The number of the shelf id of the provisioned ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.2 | INTEGER (0 | 1 | 11 | 21 | 31) | accessible-for-notify | current |
| pvxL2IntfSlotIdx OBJECT-TYPE The number of the instance id of the provisioned ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.3 | INTEGER (0..20) | accessible-for-notify | current |
| pvxL2IntfPortTypeIdx OBJECT-TYPE The number of the instance id of the provisioned ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.4 | PvxPortType | accessible-for-notify | current |
| pvxL2IntfPortIdx OBJECT-TYPE The number of the port on the circuit pack on which the ethernet facility is provisioned. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.5 | INTEGER (1..24) | accessible-for-notify | current |
| pvxL2IntfAdminStatus OBJECT-TYPE The administrative status of the Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.6 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| pvxL2IntfOperStatus OBJECT-TYPE The reported operational status of the Ethernet facility. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.7 | OperStatus | read-only | current |
| pvxL2IntfType OBJECT-TYPE This object is used to configure the type of a interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.8 | INTEGER {pnp(1), cep(2), cnpPortbased(3), cbp(4)} | read-create | current |
| pvxL2IntfSTpid OBJECT-TYPE The Ethernet type (TPID) of the S-TAG | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.9 | INTEGER {uni8100(1), nni88a8(2), nni9100(3)} | read-create | current |
| pvxL2IntfPvid OBJECT-TYPE The PVID (port-based VLAN ID) for the port | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.10 | INTEGER (1..4090) | read-create | current |
| pvxL2IntfDefaultPriority OBJECT-TYPE This object sets the default priority of the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.11 | INTEGER (0..7) | read-create | current |
| pvxL2IntfAllowedFrames OBJECT-TYPE TODO: Does this feild need to support OR of the options? | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.12 | INTEGER {all(1), vlanTagged(2), priorityTagged(3)} | read-create | current |
| pvxL2IntfIngressFiltering OBJECT-TYPE When this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames. This control does not affect VLAN independent BPDU frames, such as GVRP and STP. It does affect VLAN dependent BPDU frames, such as GMRP. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.13 | TruthValue | read-create | deprecated |
| pvxL2IntfCtrlFrmProfileId OBJECT-TYPE | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.14 | Integer32 | read-create | deprecated |
| pvxL2IntfMACAddr OBJECT-TYPE The MAC address of the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.15 | MacAddress | read-only | current |
| pvxL2IntfRateLimit OBJECT-TYPE This represents the interface rate limit in kilobits/s. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.16 | Integer32 | read-create | current |
| pvxL2IntfCoSProfileId OBJECT-TYPE This represents the Class of service profile for the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.17 | Integer32 | read-create | current |
| pvxL2IntfIsUNI OBJECT-TYPE The Switch port type. The default value set by the switch is neither. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.18 | INTEGER {neither(1), uni(2), nni(3)} | read-only | current |
| pvxL2IntfSchedProfName OBJECT-TYPE The scheduler profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.19 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfPriTCMapProfName OBJECT-TYPE The priority to traffic class map profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.20 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfPCPCodingProfName OBJECT-TYPE The scheduler profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.21 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfDscpPHBProfName OBJECT-TYPE The internal priority setting for DSCP profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.22 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfCtrlFrmProfileName OBJECT-TYPE The L2 control frame profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.23 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfUseDei OBJECT-TYPE Used by PNP port. By default, it is set to false by the switch. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.24 | TruthValue | read-create | current |
| pvxL2IntfIngressBandwidthProfile OBJECT-TYPE The ingress policy map profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.25 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfEgressBandwidthProfile OBJECT-TYPE The egress policy map profile used by the interface. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.26 | DisplayString (SIZE(0..32)) | read-create | current |
| pvxL2IntfTrustIncomingPCP OBJECT-TYPE Used by all port type. By default, it is set to true by the switch. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.27 | TruthValue | read-create | current |
| pvxL2IntfTrustIncomingDscp OBJECT-TYPE Used by all port type. By default, it is set to true by the switch. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.28 | TruthValue | read-create | current |
| pvxL2IntfBcastLimit OBJECT-TYPE Broadcast rate limit as percentage of the line rate for the port with default value of 100 (no storm control). | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.29 | INTEGER (20 | 40 | 60 | 100) | read-create | current |
| pvxL2IntfMcastLimit OBJECT-TYPE Multicast rate limit as percentage of the line rate for the port with default value of 100 (no storm control). | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.30 | INTEGER (20 | 40 | 60 | 100) | read-create | current |
| pvxL2IntfDlfLimit OBJECT-TYPE Unicast DLF rate limit as percentage of the line rate for the port with default value of 100 (no storm control). | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.31 | INTEGER (20 | 40 | 60 | 100) | read-create | current |
| pvxL2IntfRowStatus OBJECT-TYPE Used to control the addition and deletion of entries in the PVX L2 Interface table. | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.100 | RowStatus | read-create | current |
| pvxNotificationObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.14.4 | |||
| mstpNotificationObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.14.4.1 | |||
| miscellaneous OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.15 | |||
| setErrorInfo OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.15.1 | |||
| setErrorCode OBJECT-TYPE The BTI-specific error code for the set request failure. | 1.3.6.1.4.1.18070.2.2.1.15.1.1 | Integer32 | read-write | current |
| setErrorDesc OBJECT-TYPE A textual description string that explains the reason for the failed set request. | 1.3.6.1.4.1.18070.2.2.1.15.1.2 | DisplayString | read-write | current |
| opticalLayer OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.1.16 | |||
| notifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2 | |||
| eventNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1 | |||
| evtNotificationObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.1 | |||
| evtDateAndTime OBJECT-TYPE The date and time at which an event notification was issued by the system. | 1.3.6.1.4.1.18070.2.2.2.1.1.1 | DateAndTime | accessible-for-notify | current |
| tcaIntervalType OBJECT-TYPE The type of PM bin according to interval length during which a performance monitoring threshold crossing occurred. | 1.3.6.1.4.1.18070.2.2.2.1.1.2 | PMIntervalType | accessible-for-notify | current |
| tcaDateAndTime OBJECT-TYPE The date and time of the performance monitoring interval for which a performance monitoring threshold crossing alert is generated. | 1.3.6.1.4.1.18070.2.2.2.1.1.3 | DateAndTime | accessible-for-notify | current |
| tcaMontype OBJECT-TYPE Identify the performance monitoring monitored type for which a threshold crossing alert is generated. | 1.3.6.1.4.1.18070.2.2.2.1.1.4 | PMMontype | accessible-for-notify | current |
| tcaValue OBJECT-TYPE The measured value of the monitored type for which a performance monitoring threshold crossing alert is generated. | 1.3.6.1.4.1.18070.2.2.2.1.1.5 | Unsigned32 | accessible-for-notify | current |
| tcaThreshold OBJECT-TYPE The threshold for the monitored type that was exceeded resulting in the generation of a performance monnitoring threshold crossing alert. | 1.3.6.1.4.1.18070.2.2.2.1.1.6 | Unsigned32 | accessible-for-notify | current |
| evtDescription OBJECT-TYPE A textual decription of the event. | 1.3.6.1.4.1.18070.2.2.2.1.1.7 | DisplayString | accessible-for-notify | current |
| evtObjectType OBJECT-TYPE Identifies the type of managed object against which the event notification is raised. | 1.3.6.1.4.1.18070.2.2.2.1.1.8 | NotifObjectType | accessible-for-notify | current |
| evtCodeType OBJECT-TYPE This object value uniquely identifies the type of event that has been generated. | 1.3.6.1.4.1.18070.2.2.2.1.1.9 | NotifCodeType | accessible-for-notify | current |
| neEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.2 | |||
| shelfInvEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.3 | |||
| slotInvEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.4 | |||
| shelfEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.5 | |||
| cpEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.6 | |||
| oaEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.7 | |||
| dataCommsEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.8 | |||
| pluggableInvEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.9 | |||
| xcvrEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.10 | |||
| adminEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.11 | |||
| amdEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.12 | |||
| ocnEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.13 | |||
| stsnEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.14 | |||
| stmnEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.15 | |||
| vcnEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.16 | |||
| geEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.17 | |||
| fcEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.18 | |||
| ethPortEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.21 | |||
| pvxL2EvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.22 | |||
| mstpEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.23 | |||
| briEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.24 | |||
| cpSynchronizationEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.25 | |||
| pvxESrvcBWPrflEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.26 | |||
| pvxESrvcEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.27 | |||
| pvxERPSSrvcNNIEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.28 | |||
| pvxERPSSrvcEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.29 | |||
| pvxSlaMsmtEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.30 | |||
| ntpcEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.31 | |||
| pvxSUniEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.32 | |||
| olEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.33 | |||
| pvxLldpEvtNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.1.34 | |||
| conditionNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2 | |||
| neCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.1 | |||
| shelfInvCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.2 | |||
| slotInvCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.3 | |||
| shelfCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.4 | |||
| cpCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.5 | |||
| oaCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.6 | |||
| dataCommsCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.7 | |||
| pluggableInvCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.8 | |||
| xcvrCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.9 | |||
| adminCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.10 | |||
| amdCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.11 | |||
| ocnCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.12 | |||
| stsnCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.13 | |||
| stmnCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.14 | |||
| vcnCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.15 | |||
| geCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.16 | |||
| fcCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.17 | |||
| ethPortCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.20 | |||
| pvxL2PortCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.21 | |||
| mstpCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.22 | |||
| lagCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.23 | |||
| odunCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.24 | |||
| briCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.25 | |||
| ntpcCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.26 | |||
| envCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.27 | |||
| olCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.28 | |||
| erpsCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.29 | |||
| swMemberCondNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.2.30 | |||
| dbChangeNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.3 | |||
| dbChangeNotificationsObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.3.1 | |||
| dbChangeDateAndTime OBJECT-TYPE The date and time at which a database change notification was issued by the system. | 1.3.6.1.4.1.18070.2.2.2.3.1.1 | DateAndTime | accessible-for-notify | current |
| dbChangeSeqNum OBJECT-TYPE A integer value indicating the place of a database change notification message within the continual sequence of all database messages issued by the system. | 1.3.6.1.4.1.18070.2.2.2.3.1.2 | Unsigned32 | accessible-for-notify | current |
| dbChangeOID OBJECT-TYPE The OID of the object instance whose value has been changed in the database. | 1.3.6.1.4.1.18070.2.2.2.3.1.3 | OBJECT IDENTIFIER | accessible-for-notify | current |
| notificationObjects OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.4 | |||
| trapSeqNum OBJECT-TYPE A integer value indicating the place of the trap notification message within the continual sequence of all notification messages issued by the system. | 1.3.6.1.4.1.18070.2.2.2.4.1 | Unsigned32 | read-only | current |
| notificationControl OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.5 | |||
| condNotifCtrl OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.5.1 | |||
| condNotifCtrlTable OBJECT-TYPE This table contains one row for every condition notification associated with a raise. | 1.3.6.1.4.1.18070.2.2.2.5.1.1 | not-accessible | current | |
| condNotifCtrlEntry OBJECT-TYPE The conceptual row object of the condition notification control table. | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1 | not-accessible | current | |
| condNotifObjId OBJECT-TYPE The specific condition notification to set the severity for. The value must correspond to the raise condition not the clear. | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.1 | OBJECT IDENTIFIER | not-accessible | current |
| condNotifSeverity OBJECT-TYPE The severity associated with the condition notification. - Only certain values are permitted for the set: default, critial, major, minor, notAlarmed. - Only certain values are visible for the get: critial, major, minor, major-minor, notAlarmed | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.2 | CondSeverity | read-write | current |
| condNotifDefaultSeverity OBJECT-TYPE The default severity associated with the condition notification. Only certain of the CondSeverity values are visible: critial, major, minor, major-minor, notAlarmed | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.3 | CondSeverity | read-only | current |
| envCondAttrTable OBJECT-TYPE This table is used to manage the configuration of environmental alarm inputs. It contains one row for each environmental condition input on the NE. | 1.3.6.1.4.1.18070.2.2.2.5.1.2 | not-accessible | current | |
| envCondAttrEntry OBJECT-TYPE The conceptual row object of the environmental condition attribute table. | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1 | not-accessible | current | |
| envCondAttrHKIIdx OBJECT-TYPE The number of the housekeeping input which drives the activation of the environmental condition configured by this entry of the table. | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.1 | INTEGER (1..6) | not-accessible | current |
| envCondAttrSeverity OBJECT-TYPE The severity reported for the configured environmental condition when it is raised. The valid values are: - minor - major - critical - notAlarmed | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.2 | CondSeverity | read-write | current |
| envCondAttrCodeType OBJECT-TYPE The code for the specific environmental condition that is reported when the housekeeping input indicates that the condition is active. | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.3 | EnvNotifCodeType | read-write | current |
| envCondAttrDescription OBJECT-TYPE The textual decription of the environmental condition that is reported when the condition is raised. | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.4 | DisplayString (SIZE(0..40)) | read-write | current |
| envCondAttrInputType OBJECT-TYPE Specifies how the housekeeping input which drives the reporting of the environmental condition is interpreted. | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.5 | INTEGER {normallyOpen(1), normallyClosed(2), disabled(3)} | read-write | current |
| eventNotifCtrl OBJECT-IDENTITY | 1.3.6.1.4.1.18070.2.2.2.5.2 | |||
| eventNotifState OBJECT-TYPE Allows all events to be either disabled or enabled. | 1.3.6.1.4.1.18070.2.2.2.5.2.1 | INTEGER {eventsEnabled(1), eventsDisabled(2)} | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| shelfInvPluginEvt NOTIFICATION-TYPE A shelf has been detected through the shelf interconnect. | 1.3.6.1.4.1.18070.2.2.2.1.3.0.1 | current |
| shelfInvUnpluginEvt NOTIFICATION-TYPE A previously detected shelf is no longer detected through the shelf interconnect. | 1.3.6.1.4.1.18070.2.2.2.1.3.0.2 | current |
| slotInvPluginEvt NOTIFICATION-TYPE A circuit pack has been inserted into the identified slot. | 1.3.6.1.4.1.18070.2.2.2.1.4.0.1 | current |
| slotInvUnpluginEvt NOTIFICATION-TYPE A circuit pack has been removed from the identified slot. | 1.3.6.1.4.1.18070.2.2.2.1.4.0.2 | current |
| slotInvUpgradeStageResultEvt NOTIFICATION-TYPE The software upgrade process on the circuit pack in the identified slot has completed a stage. | 1.3.6.1.4.1.18070.2.2.2.1.4.0.3 | current |
| shelfStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the shelf's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.5.0.1 | current |
| cpStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the circuit pack's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.1 | current |
| cpCheckUpgradeResultEvt NOTIFICATION-TYPE Indicates the result of the check upgrade step of the system-wide software upgrade process. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.2 | current |
| cpUpgradeTransferResultEvt NOTIFICATION-TYPE Indicates the result of the software download step of the system-wide software upgrade process. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.3 | current |
| cpUpgradeStageResultEvt NOTIFICATION-TYPE The software upgrade process on the active circuit pack in the identified slot has completed a stage. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.4 | current |
| cpDbBackupResultEvt NOTIFICATION-TYPE Indicates the result of an NE database backup operation. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.5 | current |
| cpDbRestoreTransferResultEvt NOTIFICATION-TYPE Indicates the result of the database download step of the NE database restore process. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.6 | current |
| cpDbInvokeResultEvt NOTIFICATION-TYPE Indicates the result of the invoke step of the NE database restore process. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.7 | current |
| cpDbApplyResultEvt NOTIFICATION-TYPE Indicates the result of the accept step of the NE database restore process. | 1.3.6.1.4.1.18070.2.2.2.1.6.0.8 | obsolete |
| oaStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the optical amplifier's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.7.0.1 | current |
| oscStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the optical supervisory channels's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.8.0.1 | current |
| netMgmtStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the network management interface's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.8.0.2 | current |
| pluggableInvPluginEvt NOTIFICATION-TYPE A pluggable transceiver has been inserted into the identified port. | 1.3.6.1.4.1.18070.2.2.2.1.9.0.1 | current |
| pluggableInvUnpluginEvt NOTIFICATION-TYPE A pluggable transceiver has been removed from the identified port. | 1.3.6.1.4.1.18070.2.2.2.1.9.0.2 | current |
| xcvrStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the transceiver's operational status or operational status qualifier. | 1.3.6.1.4.1.18070.2.2.2.1.10.0.1 | current |
| xcvrProtSwitchEvt NOTIFICATION-TYPE A protection switch has occured on the optical transceiver facility. | 1.3.6.1.4.1.18070.2.2.2.1.10.0.2 | current |
| xcvrTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on an optical transceiver port. | 1.3.6.1.4.1.18070.2.2.2.1.10.0.3 | current |
| amdStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of an active multiplexer-demultiplexer port. | 1.3.6.1.4.1.18070.2.2.2.1.12.0.1 | obsolete |
| ocnStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a SONET OC-N facility port. | 1.3.6.1.4.1.18070.2.2.2.1.13.0.1 | current |
| ocnTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a SONET OC-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.13.0.2 | current |
| ocnProtSwitchEvt NOTIFICATION-TYPE A protection switch has occured on the identified OC-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.13.0.3 | current |
| stsnProtSwitchEvt NOTIFICATION-TYPE A protection switch has occured on the identified STS-N channel. | 1.3.6.1.4.1.18070.2.2.2.1.14.0.2 | current |
| stsnTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a SONET STS-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.14.0.3 | current |
| stmnStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a SDH STM-N facility port. | 1.3.6.1.4.1.18070.2.2.2.1.15.0.1 | current |
| stmnTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a SDH STM-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.15.0.2 | current |
| stmnProtSwitchEvt NOTIFICATION-TYPE A protection switch has occured on the identified STM-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.15.0.3 | current |
| vcnProtSwitchEvt NOTIFICATION-TYPE A protection switch has occured on the identified VC-N channel. | 1.3.6.1.4.1.18070.2.2.2.1.16.0.2 | current |
| vcnTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a SDH VC-N facility. | 1.3.6.1.4.1.18070.2.2.2.1.16.0.3 | current |
| geStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a Gigabit Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.2.1.17.0.1 | current |
| geTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a Gigabit Ethernet facility. | 1.3.6.1.4.1.18070.2.2.2.1.17.0.2 | current |
| fcStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a Fiber Channel facility port. | 1.3.6.1.4.1.18070.2.2.2.1.18.0.1 | current |
| fcTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a Fiber Channel facility. | 1.3.6.1.4.1.18070.2.2.2.1.18.0.2 | current |
| ethL1IFStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a L1 Ethernet facility port. | 1.3.6.1.4.1.18070.2.2.2.1.21.0.1 | current |
| ethL1IFTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on an Ethernet Layer 1 interface facility. | 1.3.6.1.4.1.18070.2.2.2.1.21.0.2 | current |
| pvxL2IFTcaEvt NOTIFICATION-TYPE This trap provides a threshold crossing alert for a performance monitoring statistic on a PVX Pack Ethernet Layer 2 interface facility. | 1.3.6.1.4.1.18070.2.2.2.1.22.0.2 | current |
| briStatusChangeEvt NOTIFICATION-TYPE Notification of a change in the operational status or operational status qualifier of a BRI facility port. | 1.3.6.1.4.1.18070.2.2.2.1.24.0.1 | current |
| cpSynchronizationSwitchEvt NOTIFICATION-TYPE A synchronization timing reference switch has occurred on the identified circuit pack. | 1.3.6.1.4.1.18070.2.2.2.1.25.0.1 | current |
| ntpTimeAndDateUpdateEvt NOTIFICATION-TYPE This event occurs when the NTP client updates the system date and time based on a selected reference clocks source. | 1.3.6.1.4.1.18070.2.2.2.1.31.0.1 | current |
| ntpTimingRefUpdateEvt NOTIFICATION-TYPE This event occurs when the NTP client has selected a reference clock source from a list provided. This is the NTP association list. | 1.3.6.1.4.1.18070.2.2.2.1.31.0.2 | current |
| pvxLldpRemTablesChangeEvt NOTIFICATION-TYPE A pvxLldpRemTablesChangeEvt notification is sent when the value of pvxLldpStatsRemTablesLastChangeTime changes. It can be utilized by an NMS to trigger LLDP remote systems table maintenance polls. Note that transmission of lldpRemTablesChange notifications are throttled by the agent. The agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. By default the throttling period is set to 10 seconds. | 1.3.6.1.4.1.18070.2.2.2.1.34.0.1 | current |
| shelfInvMissingCond NOTIFICATION-TYPE An expansion shelf is missing. To clear this condition, attach an appropriate expansion shelf to the MSCP in the main shelf of the system. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.1 | obsolete |
| shelfInvMissingClear NOTIFICATION-TYPE A previously active shelf missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.2 | obsolete |
| shelfInvUnknownCond NOTIFICATION-TYPE A shelf is unknown to the system. This condition occurs because the shelf is unknown to the system (for example, the the FRU data cannot be read on the expansion shelf interface (ESI) circuit pack in the expansion shelf). To clear this condition, connect an appropriate shelf to its associated MSCP. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.3 | current |
| shelfInvUnknownClear NOTIFICATION-TYPE A previously active shelf unknown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.4 | current |
| shelfInvCommCond NOTIFICATION-TYPE This condition indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.5 | obsolete |
| shelfInvCommClear NOTIFICATION-TYPE A previously active shelf communications condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.6 | obsolete |
| shelfInvPwrFeedAFailCond NOTIFICATION-TYPE There is a power feed A failure. The system can continue to function on power feed B. Plan to diagnose and correct the problem as soon as possible. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.7 | current |
| shelfInvPwrFeedAFailClear NOTIFICATION-TYPE A previously active Power feed A condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.8 | current |
| shelfInvPwrFeedBFailCond NOTIFICATION-TYPE There is a power feed B failure. The system can continue to function on power feed A. Plan to diagnose and correct the problem as soon as possible. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.9 | current |
| shelfInvPwrFeedBFailClear NOTIFICATION-TYPE A previously active Power feed B condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.10 | current |
| shelfInvPwrBrownoutCond NOTIFICATION-TYPE There is a system power brownout. As voltage levels decrease, the amplifiers fail, followed by the MSCP, and then the cooling unit fails. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.11 | current |
| shelfInvPwrBrownoutClear NOTIFICATION-TYPE A previously active power brownout condition on the shelf has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.12 | current |
| shelfInvSysCommCond NOTIFICATION-TYPE This condition indicates that backplane communication between the multiport system control processor (MSCP) and the affected circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.13 | deprecated |
| shelfInvSysCommClear NOTIFICATION-TYPE A previously active shelf missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.14 | deprecated |
| shelfInvExpansionShelfIdMismatchCond NOTIFICATION-TYPE Indicates that the identifying information of the discovered expansion shelf does not match that of the expected shelf. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.15 | current |
| shelfInvExpansionShelfIdMismatchClear NOTIFICATION-TYPE A previously active expansion shelf identifier mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.16 | current |
| shelfInvExpansionShelfCommLOSCond NOTIFICATION-TYPE This alarm indicates that a connected expansion shelf has a loss of signal between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. The most likely causes are a fiber cut or a fault with the Molex connector and cable assembly. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.17 | current |
| shelfInvExpansionShelfCommLOSClear NOTIFICATION-TYPE A previously active expansion shelf communications LOS condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.18 | current |
| shelfInvExpansionShelfCommLinkDownCond NOTIFICATION-TYPE This alarm indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.19 | current |
| shelfInvExpansionShelfCommLinkDownClear NOTIFICATION-TYPE A previously active expansion shelf communications link down condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.20 | current |
| shelfInvExpansionShelfCommDeviceUnsupportedCond NOTIFICATION-TYPE This alarm indicates that an unknown device is connected to the expansion shelf port of the multiport system control processor (MSCP) on the main shelf. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.21 | current |
| shelfInvExpansionShelfCommDeviceUnsupportedClear NOTIFICATION-TYPE A previously active expansion shelf communications device unsupported condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.22 | current |
| shelfInvTempMaxCond NOTIFICATION-TYPE Indicates that the temperature on the identified shelf has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.23 | current |
| shelfInvTempMaxClear NOTIFICATION-TYPE A previously active shelf inventory maximum temperature condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.2.0.24 | current |
| slotInvMissingCond NOTIFICATION-TYPE A Circuit pack is missing. The alarm is triggered for one of the following reasons: the provisioned circuit pack is missing from its associated slot a filler circuit pack is missing from an unprovisioned single-width or doublewidth slot a single-width circuit pack is provisioned in a double-width slot To clear this alarm, insert an appropriate single-width or double-width circuit pack or filler circuit pack in the associated single-width or double-width slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.1 | current |
| slotInvMissingClear NOTIFICATION-TYPE A previously active circuit pack or replaceable unit missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.2 | current |
| slotInvUnknownCond NOTIFICATION-TYPE Circuit pack type is unknown to the system. This condition occurs for the following two reasons: the circuit pack in the associated slot is unknown to the system (for example, the circuit pack is not supported by the software release running on the system) two single-width circuit packs are in a double-width slot To clear this condition, insert an appropriate circuit pack in the associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.3 | current |
| slotInvUnknownClear NOTIFICATION-TYPE A previously active circuit pack or replaceable unit unknown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.4 | current |
| slotInvCommCond NOTIFICATION-TYPE This alarm indicates that backplane communication between the multiport system control processor (MSCP) and the circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active. If an amplifier or wavelength conversion circuit pack has been provisioned already, it continues to operate normally. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.5 | current |
| slotInvCommClear NOTIFICATION-TYPE A previously active circuit pack communications condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.6 | current |
| slotInvFailCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.7 | current |
| slotInvFailClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.8 | current |
| slotInvUpgradeInProgressCond NOTIFICATION-TYPE A software upgrade process has begun on the circuit pack in the identified slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.9 | current |
| slotInvUpgradeInProgressClear NOTIFICATION-TYPE There is an auto upgrade in progress. This alarm is typically seen when inserting a circuit pack other than a multiport system control processor (MSCP). | 1.3.6.1.4.1.18070.2.2.2.2.3.0.10 | current |
| slotInvUpgradeFailureCond NOTIFICATION-TYPE There is a circuit pack upgrade failure. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.11 | current |
| slotInvUpgradeFailureClear NOTIFICATION-TYPE A previously active circuit pack software upgrade failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.12 | current |
| slotInvVersionMismatchCond NOTIFICATION-TYPE The circuit pack in the indicated slot is running a software version which is inconsistent with the committed software version of the system. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.13 | current |
| slotInvVersionMismatchClear NOTIFICATION-TYPE A previously active circuit pack software version mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.14 | current |
| slotInvCoolingUnitFailCond NOTIFICATION-TYPE A cooling unit failure has occurred. One or more fans have failed in the cooling unit. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.15 | current |
| slotInvCoolingUnitFailClear NOTIFICATION-TYPE A previously active shelf cooling unit failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.16 | current |
| slotInvDspCommCond NOTIFICATION-TYPE This alarm indicates that communication has failed either between the DSP and the processor handling backplane communications on an optical amplifier circuit pack, or between the variable optical equalizer (VOE) and the processor handling backplane communications on an active mux/demux circuit pack Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.17 | current |
| slotInvDspCommClear NOTIFICATION-TYPE A previously active DSP control communications condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.18 | current |
| slotInvUnsupportedPackCond NOTIFICATION-TYPE A replaceable unit inventory item is unsupported. In this case, a multiport system control processor (MSCP) circuit pack is plugged into any slot of the expansion shelf. However, MSCPs are only supported in slot five of the main shelf. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.19 | current |
| slotInvUnsupportedPackClear NOTIFICATION-TYPE A previously active unsupported pack condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.20 | current |
| slotInvCoolingUnitMismatchCond NOTIFICATION-TYPE The shelf is plugged in with a wring cooling unit. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.21 | current |
| slotInvCoolingUnitMismatchClear NOTIFICATION-TYPE A previously active cooling unit mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.22 | current |
| slotInvPwrFeedAFuseFailCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.23 | current |
| slotInvPwrFeedAFuseFailClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.24 | current |
| slotInvPwrFeedBFuseFailCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.25 | current |
| slotInvPwrFeedBFuseFailClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.26 | current |
| slotInvPowerFailCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.27 | current |
| slotInvPowerFailClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.28 | current |
| slotInvHiTempAutoShutdownCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.29 | current |
| slotInvHiTempAutoShutdownClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.30 | current |
| slotInvHTThreshExceededCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.31 | current |
| slotInvHTThreshExceededClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.32 | current |
| slotInvHTSThreshExceededCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.33 | current |
| slotInvHTSThreshExceededClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.34 | current |
| slotInvHTASUnsupportedCond NOTIFICATION-TYPE There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.35 | current |
| slotInvHTASUnsupportedClear NOTIFICATION-TYPE A previously active circuit pack fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.3.0.36 | current |
| shelfMismatchCond NOTIFICATION-TYPE The type of the physically detected shelf does not match the provisioned shelf type. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.1 | current |
| shelfMismatchClear NOTIFICATION-TYPE A previously active shelf type mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.2 | current |
| shelfMissingCond NOTIFICATION-TYPE An expansion shelf is missing. To clear this alarm, attach an appropriate expansion shelf to the MSCP in the main shelf of the system. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.3 | current |
| shelfMissingClear NOTIFICATION-TYPE A previously active expansion shelf missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.4 | current |
| shelfConfigurationMismatchCond NOTIFICATION-TYPE The configuration type of the physically detected expansion shelf does not match the provisioned expansion shelf configuration type. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.5 | deprecated |
| shelfConfigurationMismatchClear NOTIFICATION-TYPE A previously active expansion shelf configuration mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.4.0.6 | deprecated |
| cpMismatchCond NOTIFICATION-TYPE There is a circuit pack mismatch. There is a mismatch between the equipment provisioned for the slot and the physical circuit pack that is inserted in the slot. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.1 | current |
| cpMismatchClear NOTIFICATION-TYPE A previously active circuit pack type mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.2 | current |
| cpConnectorMismatchCond NOTIFICATION-TYPE A connector mismatch alarm occurs on a circuit pack that is provisioned with a connector type that is different to the one actually inserted. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.3 | current |
| cpConnectorMismatchClear NOTIFICATION-TYPE A previously active optical fiber connector type mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.4 | current |
| cpInvalidProvCond NOTIFICATION-TYPE The type of circuit pack that is provisioned in a slot that is invalid for the shelf slot configuration. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.5 | current |
| cpInvalidProvClear NOTIFICATION-TYPE A previously active invalid circuit pack provisioning condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.6 | current |
| cpSoftwareBankAFailCond NOTIFICATION-TYPE There is a hardware failure in software bank A storage device. During this alarm, software backups, upgrades and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.7 | current |
| cpSoftwareBankAFailClear NOTIFICATION-TYPE A previously active software Bank A failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.8 | current |
| cpSoftwareBankBFailCond NOTIFICATION-TYPE There is a hardware failure in software bank B storage device. During this alarm, software backups, upgrades, and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.9 | current |
| cpSoftwareBankBFailClear NOTIFICATION-TYPE A previously active software Bank B failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.10 | current |
| cpUpgradeInProgressCond NOTIFICATION-TYPE Indicates that a system-wide software upgrade process is in progress on the NE. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.11 | current |
| cpUpgradeInProgressClear NOTIFICATION-TYPE A previously active system-wide upgrade in progress condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.12 | current |
| cpUpgradeFailCond NOTIFICATION-TYPE Indicates that the system-wide upgrade procedure has failed to complete successfully. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.15 | current |
| cpUpgradeFailClear NOTIFICATION-TYPE A previously active circuit pack upgrade failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.16 | current |
| cpDbRestoreInProgressCond NOTIFICATION-TYPE There is a database restore in progress on the system. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.17 | current |
| cpDbRestoreInProgressClear NOTIFICATION-TYPE A previously active NE database restore condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.18 | current |
| cpDbRecoveryFailCond NOTIFICATION-TYPE There is a database recovery failure. If a new MSCP circuit pack fails to acquire the database from the system, a database recovery failure alarm can be triggered after replacing the MSCP. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.19 | current |
| cpDbRecoveryFailClear NOTIFICATION-TYPE A previously active NE database recovery failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.20 | current |
| cpFanFeedFailCond NOTIFICATION-TYPE A cooling unit feed failure has occurred on a BTI 7030 shelf. There are two cooling unit power feeds from the SCP to the cooling unit. If one power feeds fails, a minor alarm is raised. If both power feed fails, a major alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.21 | current |
| cpFanFeedFailClear NOTIFICATION-TYPE A previously active fan power feed failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.22 | current |
| cpStorageCardFailCond NOTIFICATION-TYPE Indicates that the database storage card has failed. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.23 | current |
| cpStorageCardFailClear NOTIFICATION-TYPE A previously active database storage card failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.24 | current |
| cpDbDeletionInProgressCond NOTIFICATION-TYPE There is a database deletion in progress on the system. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.25 | current |
| cpDbDeletionInProgressClear NOTIFICATION-TYPE A previously active NE database deletion condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.26 | current |
| cpDegradeCond NOTIFICATION-TYPE Indicates that a failure or degradation has been detected in one or more physical components on the identified circuit pack, which may lead to a failure of the pack to provide service normally. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.27 | current |
| cpDegradeClear NOTIFICATION-TYPE A previously active Circuit Pack Degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.5.0.28 | current |
| oaCaseTempCond NOTIFICATION-TYPE A case temperature high threshold is exceeded. A warning is raised to indicate that the amplifier is nearing its shutdown threshold. The circuit pack in the associated slot has exceeded its case temperature high threshold. If the case temperature continues to rise to its shutdown threshold, the circuit pack automatically shuts down. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.1 | current |
| oaCaseTempClear NOTIFICATION-TYPE A previously active optical amplifier case temperature condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.2 | current |
| oaCaseTempShutdownCond NOTIFICATION-TYPE A case temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. The pump lasers are turned off and there is no amplification. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.3 | current |
| oaCaseTempShutdownClear NOTIFICATION-TYPE A previously active optical amplifier case temperature shutdown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.4 | current |
| oaLaserMinTempShutdownCond NOTIFICATION-TYPE A pump laser temperature low threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.5 | current |
| oaLaserMinTempShutdownClear NOTIFICATION-TYPE A previously active optical amplifier minimum temperature shutdown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.6 | current |
| oaLaserMaxTempShutdownCond NOTIFICATION-TYPE A pump laser temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.7 | current |
| oaLaserMaxTempShutdownClear NOTIFICATION-TYPE A previously active optical amplifier maximum temperature shutdown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.8 | current |
| oaOpticalPwrReceivedMinCond NOTIFICATION-TYPE The optical power received (OPR) low threshold is exceeded. The input signal to an optical amplifier has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the circuit pack will degrade in performance. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.9 | current |
| oaOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active optical amplifier minimum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.10 | current |
| oaOpticalPwrReceivedMaxCond NOTIFICATION-TYPE The optical power received (OPR) high threshold is crossed. The input signal to an optical amplifier has reached the optical power received high threshold. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.11 | current |
| oaOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active optical amplifier maximum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.12 | current |
| oaSSIOpticalPwrReceivedMaxCond NOTIFICATION-TYPE A second stage input optical power received (OPR) high threshold crossing has occurred. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.13 | current |
| oaSSIOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active optical amplifier second stage input maximum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.14 | current |
| oaBackReflectionSafetyCond NOTIFICATION-TYPE The Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the optical power received optical back reflection high threshold safety override (OPR-OBR-HTSO) command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.17 | current |
| oaBackReflectionSafetyClear NOTIFICATION-TYPE A previously active optical amplifier back reflection safety condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.18 | current |
| oaOpticalPwrTransmittedMinCond NOTIFICATION-TYPE The optical power transmitted (OPT) low threshold is crossed. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.19 | current |
| oaOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active optical amplifier minimum transmitted power condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.20 | current |
| oaOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE The optical power transmitted (OPT) high threshold has been exceeded on the amplifier. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.21 | current |
| oaOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active optical amplifier maximum transmitted power condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.22 | current |
| oaMSInsertionLossCond NOTIFICATION-TYPE A mid-stage insertion loss high threshold is exceeded for a mid-stage amplifier. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.23 | current |
| oaMSInsertionLossClear NOTIFICATION-TYPE A previously active optical amplifier midstage insertion loss condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.24 | current |
| oaAmplifierConditioningCond NOTIFICATION-TYPE There is an amplifier conditioning problem. When an amplifier is initially plugged in, thermo-electric coolers (TEC) work to control the pump laser temperature to between 16 degrees and 34 degrees Celsius. Until the pump laser temperature is within range, the amplifier conditioning problem is present. If the amplifier conditioning problem persists for more than 30 minutes, the condition is cleared and either a laser temperature low threshold or a laser temperature high threshold alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.25 | current |
| oaAmplifierConditioningClear NOTIFICATION-TYPE A previously active optical amplifier conditioning condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.26 | current |
| oaDspCommCond NOTIFICATION-TYPE This alarm indicates that communication has failed between the DSP and the processor handling backplane communications on an optical amplifier circuit pack. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.27 | current |
| oaDspCommClear NOTIFICATION-TYPE A previously active optical amplifier DSP communications condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.28 | current |
| oaBackReflectionSafetyOverrideCond NOTIFICATION-TYPE The Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the high threshold safety override command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.41 | current |
| oaBackReflectionSafetyOverrideClear NOTIFICATION-TYPE A previously active back reflection safety override condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.42 | current |
| oaBackReflectionHighThresholdCond NOTIFICATION-TYPE The Optical Amplifier Back Reflection High Threshold alarm indicates that the measured optical back reflection power has exceeded the high threshold. This serves as a warning that optical back reflection is operating at an elevated level, and that continued increases in the optical back reflection level may result in an automatic laser safety shutdown. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.43 | current |
| oaBackReflectionHighThresholdClear NOTIFICATION-TYPE A previously active back reflection high threshold condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.6.0.44 | current |
| oscLossOfSignalCond NOTIFICATION-TYPE This condition indicates that an SFP transceiver has experienced an input power drop that is below the manufacturer s preset threshold. | 1.3.6.1.4.1.18070.2.2.2.2.7.0.1 | current |
| oscLossOfSignalClear NOTIFICATION-TYPE A previously active optical supervisory channel loss of signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.7.0.2 | current |
| oscSfpMissingCond NOTIFICATION-TYPE An SFP transceiver is missing from its associated port in an MSCP circuit pack. To clear this alarm, insert an appropriate transceiver in the associated port of the MSCP circuit pack. | 1.3.6.1.4.1.18070.2.2.2.2.7.0.3 | current |
| oscSfpMissingClear NOTIFICATION-TYPE A previously active optical supervisory channel SFP missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.7.0.4 | current |
| pluggableInvUnknownCond NOTIFICATION-TYPE The SFP or XFP transceiver type is unknown to the system. This alarm occurs because the transceiver is not supported by the current software. To clear this alarm, insert a readable SFP or XFP transceiver in the associated port of the circuit pack. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.1 | current |
| pluggableInvUnknownClear NOTIFICATION-TYPE A previously active Pluggable Inventory Unknown condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.2 | current |
| pluggableInvCommCond NOTIFICATION-TYPE This alarm indicates that communication between a circuit pack and an inserted small form factor pluggable (SFP) transceiver is not reliable. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.3 | current |
| pluggableInvCommClear NOTIFICATION-TYPE A previously active Pluggable Inventory communications condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.4 | current |
| pluggableInvFailCond NOTIFICATION-TYPE There is an SFP or XFP transceiver failure. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.5 | current |
| pluggableInvFailClear NOTIFICATION-TYPE A previously active Pluggable Inventory fail condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.6 | current |
| pluggableInvMismatchCond NOTIFICATION-TYPE There is an SFP mismatch condition active. There is a mismatch between the SFP transceiver provisioned for a port of a circuit pack and the physical SFP transceiver that is inserted in the port. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.7 | current |
| pluggableInvMismatchClear NOTIFICATION-TYPE A previously active Pluggable Inventory mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.8 | current |
| pluggableInvMissingCond NOTIFICATION-TYPE There is an SFP or XFP missing from the indicated port. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.9 | current |
| pluggableInvMissingClear NOTIFICATION-TYPE A previously active Pluggable Inventory missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.10 | current |
| pluggableInvUnsupportedCond NOTIFICATION-TYPE The electrical SFP transceiver type is NOT supported in the given port. This alarm occurs when an electrical SFP is plugged into a port that does not support GE. To clear this alarm, remove the electrical SFP. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.11 | current |
| pluggableInvUnsupportedClear NOTIFICATION-TYPE A previously active Pluggable unsupported condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.8.0.12 | current |
| xcvrMissingCond NOTIFICATION-TYPE An SFP or XFP transceiver is missing from its associated port in a circuit pack. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.1 | current |
| xcvrMissingClear NOTIFICATION-TYPE A previously active transceiver port missing condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.2 | current |
| xcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for a port of a circuit pack and the physical SFP or XFP transceiver that is inserted in the port. The provisioned SFP or XFP transceiver must match the transceiver in the port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.3 | current |
| xcvrMismatchClear NOTIFICATION-TYPE A previously active transceiver port type mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.4 | current |
| xcvrRFICond NOTIFICATION-TYPE Remote Fault Indication: The source port to which the specified destination transceiver port is cross-connected has a service-affecting fault active against it. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.5 | current |
| xcvrRFIClear NOTIFICATION-TYPE A previously active transceiver RFI condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.6 | current |
| xcvrLossOfSignalCond NOTIFICATION-TYPE This alarm indicates that an SFP transceiver has experienced an input power drop that is below the preset minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.7 | current |
| xcvrLossOfSignalClear NOTIFICATION-TYPE A previously active transceiver port Loss Of Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.8 | current |
| xcvrLossOfLockCond NOTIFICATION-TYPE This alarm indicates that a transceiver port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.9 | current |
| xcvrLossOfLockClear NOTIFICATION-TYPE A previously active transceiver port Loss Of Lock condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.10 | current |
| xcvrOpticalPwrReceivedMinCond NOTIFICATION-TYPE The optical power received (OPR) low threshold is not met. The input signal to a transceiver has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the transceiver degrades in performance. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.11 | current |
| xcvrOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active transceiver port minimum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.12 | current |
| xcvrOpticalPwrReceivedMaxCond NOTIFICATION-TYPE The optical power received (OPR) high threshold is exceeded. The input signal to a transceiver has reached the optical power received high threshold. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.13 | current |
| xcvrOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active transceiver port maximum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.14 | current |
| xcvrOpticalPwrTransmittedMinCond NOTIFICATION-TYPE The optical power transmitted (OPT) is below the low threshold for the transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.15 | current |
| xcvrOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active transceiver port minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.16 | current |
| xcvrOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE The optical power transmitted (OPT) high threshold for a transceiver is exceeded. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.17 | current |
| xcvrOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active transceiver port maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.18 | current |
| xcvrLossOfFrameCond NOTIFICATION-TYPE A transceiver reports a SONET or SDH loss of frame for a transceiver that is provisioned to receive a SONET or SDH protocol. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.19 | current |
| xcvrLossOfFrameClear NOTIFICATION-TYPE A previously active loss of frame condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.20 | current |
| xcvrLossOfSyncCond NOTIFICATION-TYPE Indicates that a loss of synchronization condition has been detected by the transceiver port on the incoming gigabit ethernet or 10GELAN protocol. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.21 | current |
| xcvrLossOfSyncClear NOTIFICATION-TYPE A previously active loss of synchronization condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.22 | current |
| xcvrLoopbackCond NOTIFICATION-TYPE Indicates that the transceiver has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.27 | current |
| xcvrLoopbackClear NOTIFICATION-TYPE A previously active loopback condition on the transceiver has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.28 | current |
| xcvrForcedSwitchToProtectionCond NOTIFICATION-TYPE The active transceiver of a protected transceiver pair has been forced to switch to the Protection transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.29 | current |
| xcvrForcedSwitchToProtectionClear NOTIFICATION-TYPE A previously active Forced Switch To Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.30 | current |
| xcvrForcedSwitchToWorkingCond NOTIFICATION-TYPE The active transceiver of a protected transceiver pair has been forced to switch to the Working transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.31 | current |
| xcvrForcedSwitchToWorkingClear NOTIFICATION-TYPE A previously active Forced Switch To Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.32 | current |
| xcvrLockoutProtectionCond NOTIFICATION-TYPE The Protection transceiver of a protected transceiver pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.33 | current |
| xcvrLockoutProtectionClear NOTIFICATION-TYPE A previously active Lockout Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.34 | current |
| xcvrLockoutWorkingCond NOTIFICATION-TYPE The Working transceiver of a protected transceiver pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.35 | current |
| xcvrLockoutWorkingClear NOTIFICATION-TYPE A previously active Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.36 | current |
| xcvrTempMaxCond NOTIFICATION-TYPE Indicates that the temperature of the physical transceiver has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.37 | current |
| xcvrTempMaxClear NOTIFICATION-TYPE A previously active Temperature Exceeded Maximum condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.38 | current |
| xcvrWavelengthNotAchievableCond NOTIFICATION-TYPE Indicates that the transceiver is not currently able to tune to the set wavelength. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.39 | current |
| xcvrWavelengthNotAchievableClear NOTIFICATION-TYPE A previously active Wavelength Not Achievable condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.40 | current |
| xcvrAlarmIndicationSignalCond NOTIFICATION-TYPE An Alarm Indication Signal indication is active on the transceiver port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.41 | current |
| xcvrAlarmIndicationSignalClear NOTIFICATION-TYPE A previously active Alarm Indication Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.42 | current |
| xcvrTraceMismatchCond NOTIFICATION-TYPE This condition indicates that the received trace label on the transciever port does not match the expected trace label. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.43 | current |
| xcvrTraceMismatchClear NOTIFICATION-TYPE A previously active Trace Mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.44 | current |
| xcvrRemoteFaultCond NOTIFICATION-TYPE A remote fault indication is active on the traceiver port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.45 | current |
| xcvrRemoteFaultClear NOTIFICATION-TYPE A previously raised remote fault indication has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.46 | current |
| xcvrSignalDegradeCond NOTIFICATION-TYPE The Signal Degrade BER threshold has been crossed on the transiever port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.47 | current |
| xcvrSignalDegradeClear NOTIFICATION-TYPE A previously active Signal Degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.48 | current |
| xcvrOTNPayloadMismatchCond NOTIFICATION-TYPE An OTN payload mismatch is active on the transceiver port facility. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.49 | current |
| xcvrOTNPayloadMismatchClear NOTIFICATION-TYPE A previously active OTN payload mismatch condition on the transceiver port facility has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.50 | current |
| xcvrLFCond NOTIFICATION-TYPE Local Failure: Raised when a port detects and incoming local failure indication is received. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.51 | current |
| xcvrLFClear NOTIFICATION-TYPE A previously active transceiver LF condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.52 | current |
| xcvrOpenConnectionIndicatorCond NOTIFICATION-TYPE An Open Connection Indicator is active on the transceiver port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.53 | current |
| xcvrOpenConnectionIndicatorClear NOTIFICATION-TYPE A previously active Open Connection Indicator condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.54 | current |
| xcvrReceivedLockoutCond NOTIFICATION-TYPE A Received Lockout indication is active on the transceiver port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.55 | current |
| xcvrReceivedLockoutClear NOTIFICATION-TYPE A previously active Received Lockout condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.56 | current |
| xcvrBackwardDefectIndicatorCond NOTIFICATION-TYPE A Backward Defect Indicator is active on the transceiver port. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.57 | current |
| xcvrBackwardDefectIndicatorClear NOTIFICATION-TYPE A previously active Backward Defect Indicator condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.9.0.58 | current |
| tl1UserLockoutCond NOTIFICATION-TYPE A user is locked out of the system. After three incorrect attempts to login, a user is blocked from attempting to login again for 60 seconds. | 1.3.6.1.4.1.18070.2.2.2.2.10.0.1 | current |
| tl1UserLockoutClear NOTIFICATION-TYPE A previously active TL1 User Lockout condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.10.0.2 | current |
| tl1IpLockoutCond NOTIFICATION-TYPE After three incorrect attempts to login from the same IP address, the IP address from which the three attempts are made is blocked for 60 seconds. When this condition is present in the actCondTable, the actCondTableEntryIdx will be set to the networkElement OID and the actCondInstanceIdx will be set to 0. | 1.3.6.1.4.1.18070.2.2.2.2.10.0.3 | current |
| tl1IpLockoutClear NOTIFICATION-TYPE A previously active TL1 IP lockout condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.10.0.4 | current |
| amdLossOfSignalCond NOTIFICATION-TYPE This condition indicates that an active mux/demux that has experienced an input power drop that is below the preset threshold. This can be against either a channel or the composite line port. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.1 | obsolete |
| amdLossOfSignalClear NOTIFICATION-TYPE A previously raised active multiplexer-demultiplexer loss of signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.2 | obsolete |
| amdOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the active multiplexer-demultiplexer facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.3 | obsolete |
| amdOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously raised active multiplexer-demultiplexer minimum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.4 | obsolete |
| amdOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the active multiplexer-demultiplexer facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.5 | obsolete |
| amdOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously raised active multiplexer-demultiplexer maximum power received condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.6 | obsolete |
| amdTPLNACond NOTIFICATION-TYPE A channel target power level not achieved (TPLNA) condition is triggered when the output power for a channel of a 32-Channel DWDM Active Mux/Demux (D32AMD) module is above or below the target power transmitted level for that channel. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.7 | obsolete |
| amdTPLNAClear NOTIFICATION-TYPE A previously raised active target power level not achieved condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.8 | obsolete |
| amdTALNACond NOTIFICATION-TYPE The target attenuation level not achieved (TALNA) condition is triggered when the attenuation for a 32-Channel DWDM Active Mux/Demux (D32AMD) is outside the preset attenuation levels for a composite line. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.9 | obsolete |
| amdTALNAClear NOTIFICATION-TYPE A previously raised active target attenuation level not achieved condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.11.0.10 | obsolete |
| ocnLossOfSignalCond NOTIFICATION-TYPE This notification indicates that there is no input signal detected on the OC-N port. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.1 | current |
| ocnLossOfSignalClear NOTIFICATION-TYPE This notification indicates that a previously active OC-N Loss of Signal condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.2 | current |
| ocnXcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for the OC-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the OC-N facility. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.3 | current |
| ocnXcvrMismatchClear NOTIFICATION-TYPE A previously active OC-N Mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.4 | current |
| ocnOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the OC-N facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.5 | current |
| ocnOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active OC-N minimum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.6 | current |
| ocnOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the OC-N facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.7 | current |
| ocnOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active OC-N maximum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.8 | current |
| ocnOpticalPwrTransmittedMinCond NOTIFICATION-TYPE Indicates that the output power for the OC-N facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.9 | current |
| ocnOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active OC-N minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.10 | current |
| ocnOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE Indicates that the output power for the OC-N facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.11 | current |
| ocnOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active OC-N maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.12 | current |
| ocnLossOfFrameCond NOTIFICATION-TYPE An OC-N Loss of Frame condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.13 | current |
| ocnLossOfFrameClear NOTIFICATION-TYPE A previously active OC-N Loss of Frame condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.14 | current |
| ocnSignalDegradeCond NOTIFICATION-TYPE A signal degrade condition on the OC-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.15 | current |
| ocnSignalDegradeClear NOTIFICATION-TYPE A previously active OC-N Signal Degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.16 | current |
| ocnAlarmIndicationSignalCond NOTIFICATION-TYPE An OC-N Line-level Alarm Indication Signal indication is active on facility. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.17 | current |
| ocnAlarmIndicationSignalClear NOTIFICATION-TYPE A previously active OC-N Alarm Indication Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.18 | current |
| ocnLoopbackCond NOTIFICATION-TYPE Indicates that the OC-N facility has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.19 | current |
| ocnLoopbackClear NOTIFICATION-TYPE A previously active loopback condition on the OC-N facility has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.20 | current |
| ocnLossOfPrimaryTimingReferenceCond NOTIFICATION-TYPE Indicates that the primary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.21 | current |
| ocnLossOfPrimaryTimingReferenceClear NOTIFICATION-TYPE A previously active OC-N Loss of Primary Timing Reference condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.22 | current |
| ocnLossOfSecondaryTimingReferenceCond NOTIFICATION-TYPE Indicates that the secondary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.23 | current |
| ocnLossOfSecondaryTimingReferenceClear NOTIFICATION-TYPE A previously active OC-N Loss of Secondary Timing Reference condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.24 | current |
| ocnOTNPayloadMismatchCond NOTIFICATION-TYPE An OTN payload mismatch is active on the facility. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.25 | current |
| ocnOTNPayloadMismatchClear NOTIFICATION-TYPE A previously active OTN payload mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.26 | current |
| ocnForcedSwitchToProtectionCond NOTIFICATION-TYPE The active line of a protected line pair has been forced to switch to the Protection line. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.27 | current |
| ocnForcedSwitchToProtectionClear NOTIFICATION-TYPE A previously active Forced Switch To Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.28 | current |
| ocnForcedSwitchToWorkingCond NOTIFICATION-TYPE The active line of a protected line pair has been forced to switch to the Working line. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.29 | current |
| ocnForcedSwitchToWorkingClear NOTIFICATION-TYPE A previously active Forced Switch To Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.30 | current |
| ocnLockoutProtectionCond NOTIFICATION-TYPE The Protection line of a protected line pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.31 | current |
| ocnLockoutProtectionClear NOTIFICATION-TYPE A previously active Lockout Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.32 | current |
| ocnLockoutWorkingCond NOTIFICATION-TYPE The Working line of a protected line pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.33 | current |
| ocnLockoutWorkingClear NOTIFICATION-TYPE A previously active Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.34 | current |
| ocnWavelengthNotAchievableCond NOTIFICATION-TYPE The tunable pluggable cannot be tuned to the provisioned wavelength. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.35 | current |
| ocnWavelengthNotAchievableClear NOTIFICATION-TYPE A previously active Wavelength Not Achievable condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.12.0.36 | current |
| stsnAlarmIndicationSignalCond NOTIFICATION-TYPE A Path-level Alarm Indication Signal indication is active on the STS-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.1 | current |
| stsnAlarmIndicationSignalClear NOTIFICATION-TYPE A previously active STS-N Alarm Indication Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.2 | current |
| stsnLossOfPointerCond NOTIFICATION-TYPE A Loss of Pointer condition is active on the STS-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.3 | current |
| stsnLossOfPointerClear NOTIFICATION-TYPE A previously raised STS-N Loss of Pointer condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.4 | current |
| stsnUnequippedCond NOTIFICATION-TYPE An Unequipped indication has been detected for the STS-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.5 | current |
| stsnUnequippedClear NOTIFICATION-TYPE A previously raised STS-N Unequipped condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.6 | current |
| stsnSignalDegradeCond NOTIFICATION-TYPE A signal degrade condition on the STS-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.7 | current |
| stsnSignalDegradeClear NOTIFICATION-TYPE A previously raised STS-N signal degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.8 | current |
| stsnForcedSwitchToProtectionCond NOTIFICATION-TYPE The active STS-N channel of a protected STS-N channel pair has been forced to switch to the Protection transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.9 | current |
| stsnForcedSwitchToProtectionClear NOTIFICATION-TYPE A previously raised STS-N Forced Switch To Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.10 | current |
| stsnForcedSwitchToWorkingCond NOTIFICATION-TYPE The active STS-N channel of a protected STS-N channel pair has been forced to switch to the Working transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.11 | current |
| stsnForcedSwitchToWorkingClear NOTIFICATION-TYPE A previously raised STS-N Forced Switch To Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.12 | current |
| stsnLockoutProtectionCond NOTIFICATION-TYPE The Protection STS-N channel of a protected STS-N channel pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.13 | current |
| stsnLockoutProtectionClear NOTIFICATION-TYPE A previously raised STS-N Lockout Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.14 | current |
| stsnLockoutWorkingCond NOTIFICATION-TYPE The Working STS-N channel of a protected STS-N channel pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.15 | current |
| stsnLockoutWorkingClear NOTIFICATION-TYPE A previously raised STS-N Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.16 | current |
| stsnConcatMismatchCond NOTIFICATION-TYPE A connection provisioning does not match has been detected for the STS-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.17 | current |
| stsnConcatMismatchClear NOTIFICATION-TYPE A previously raised STS-N Concat Mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.13.0.18 | current |
| stmnLossOfSignalCond NOTIFICATION-TYPE This notification indicates that there is no input signal detected on the STM-N port. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.1 | current |
| stmnLossOfSignalClear NOTIFICATION-TYPE This notification indicates that a previously active STM-N Loss of Signal condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.2 | current |
| stmnXcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for the STM-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the STM-N facility. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.3 | current |
| stmnXcvrMismatchClear NOTIFICATION-TYPE A previously active STM-N Mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.4 | current |
| stmnOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the STM-N facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.5 | current |
| stmnOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active STM-N minimum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.6 | current |
| stmnOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the STM-N facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.7 | current |
| stmnOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active STM-N maximum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.8 | current |
| stmnOpticalPwrTransmittedMinCond NOTIFICATION-TYPE Indicates that the output power for the STM-N facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.9 | current |
| stmnOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active STM-N minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.10 | current |
| stmnOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE Indicates that the output power for the STM-N facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.11 | current |
| stmnOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active STM-N maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.12 | current |
| stmnLossOfFrameCond NOTIFICATION-TYPE An STM-N Loss of Frame condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.13 | current |
| stmnLossOfFrameClear NOTIFICATION-TYPE A previously active STM-N Loss of Frame condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.14 | current |
| stmnSignalDegradeCond NOTIFICATION-TYPE A signal degrade condition on the STM-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.15 | current |
| stmnSignalDegradeClear NOTIFICATION-TYPE A previously active STM-N Signal Degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.16 | current |
| stmnAlarmIndicationSignalCond NOTIFICATION-TYPE An STM-N Line-level Alarm Indication Signal indication is active on facility. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.17 | current |
| stmnAlarmIndicationSignalClear NOTIFICATION-TYPE A previously active STM-N Alarm Indication Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.18 | current |
| stmnLoopbackCond NOTIFICATION-TYPE Indicates that the STM-N facility has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.19 | current |
| stmnLoopbackClear NOTIFICATION-TYPE A previously active loopback condition on the STM-N facility has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.20 | current |
| stmnLossOfPrimaryTimingReferenceCond NOTIFICATION-TYPE Indicates that the primary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.21 | current |
| stmnLossOfPrimaryTimingReferenceClear NOTIFICATION-TYPE A previously active STM-N Loss of Primary Timing Reference condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.22 | current |
| stmnLossOfSecondaryTimingReferenceCond NOTIFICATION-TYPE Indicates that the secondary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.23 | current |
| stmnLossOfSecondaryTimingReferenceClear NOTIFICATION-TYPE A previously active STM-N Loss of Secondary Timing Reference condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.24 | current |
| stmnOTNPayloadMismatchCond NOTIFICATION-TYPE An OTN payload mismatch is active on the facility. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.25 | current |
| stmnOTNPayloadMismatchClear NOTIFICATION-TYPE A previously active OTN payload mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.26 | current |
| stmnForcedSwitchToProtectionCond NOTIFICATION-TYPE The active line of a protected line pair has been forced to switch to the Protection line. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.27 | current |
| stmnForcedSwitchToProtectionClear NOTIFICATION-TYPE A previously active Forced Switch To Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.28 | current |
| stmnForcedSwitchToWorkingCond NOTIFICATION-TYPE The active line of a protected line pair has been forced to switch to the Working line. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.29 | current |
| stmnForcedSwitchToWorkingClear NOTIFICATION-TYPE A previously active Forced Switch To Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.30 | current |
| stmnLockoutProtectionCond NOTIFICATION-TYPE The Protection line of a protected line pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.31 | current |
| stmnLockoutProtectionClear NOTIFICATION-TYPE A previously active Lockout Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.32 | current |
| stmnLockoutWorkingCond NOTIFICATION-TYPE The Working line of a protected line pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.33 | current |
| stmnLockoutWorkingClear NOTIFICATION-TYPE A previously active Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.34 | current |
| stmnWavelengthNotAchievableCond NOTIFICATION-TYPE A previously active Wavelength Not Achievable condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.35 | current |
| stmnWavelengthNotAchievableClear NOTIFICATION-TYPE A previously active Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.14.0.36 | current |
| vcnAlarmIndicationSignalCond NOTIFICATION-TYPE A Path-level Alarm Indication Signal indication is active on the VC-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.1 | current |
| vcnAlarmIndicationSignalClear NOTIFICATION-TYPE A previously active VC-N Alarm Indication Signal condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.2 | current |
| vcnLossOfPointerCond NOTIFICATION-TYPE A Loss of Pointer condition is active on the VC-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.3 | current |
| vcnLossOfPointerClear NOTIFICATION-TYPE A previously raised VC-N Loss of Pointer condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.4 | current |
| vcnUnequippedCond NOTIFICATION-TYPE An Unequipped indication has been detected for the VC-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.5 | current |
| vcnUnequippedClear NOTIFICATION-TYPE A previously raised VC-N Unequipped condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.6 | current |
| vcnSignalDegradeCond NOTIFICATION-TYPE A signal degrade condition on the VC-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.7 | current |
| vcnSignalDegradeClear NOTIFICATION-TYPE A previously raised VC-N signal degrade condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.8 | current |
| vcnForcedSwitchToProtectionCond NOTIFICATION-TYPE The active VC-N channel of a protected VC-N channel pair has been forced to switch to the Protection transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.9 | current |
| vcnForcedSwitchToProtectionClear NOTIFICATION-TYPE A previously raised VC-N Forced Switch To Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.10 | current |
| vcnForcedSwitchToWorkingCond NOTIFICATION-TYPE The active VC-N channel of a protected VC-N channel pair has been forced to switch to the Working transceiver. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.11 | current |
| vcnForcedSwitchToWorkingClear NOTIFICATION-TYPE A previously raised VC-N Forced Switch To Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.12 | current |
| vcnLockoutProtectionCond NOTIFICATION-TYPE The Protection VC-N channel of a protected VC-N channel pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.13 | current |
| vcnLockoutProtectionClear NOTIFICATION-TYPE A previously raised VC-N Lockout Protection condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.14 | current |
| vcnLockoutWorkingCond NOTIFICATION-TYPE The Working VC-N channel of a protected VC-N channel pair has been locked out. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.15 | current |
| vcnLockoutWorkingClear NOTIFICATION-TYPE A previously raised VC-N Lockout Working condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.16 | current |
| vcnConcatMismatchCond NOTIFICATION-TYPE A connection provisioning does not match has been detected for the VC-N channel. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.17 | current |
| vcnConcatMismatchClear NOTIFICATION-TYPE A previously raised VC-N Concat Mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.15.0.18 | current |
| geLossOfSignalCond NOTIFICATION-TYPE This notification indicates that there is no input signal detected on the Gigabit Ethernet port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.1 | current |
| geLossOfSignalClear NOTIFICATION-TYPE This notification indicates that a previously active GE Loss of Signal condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.2 | current |
| geXcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for the Gigabit Ethernet facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the GE facility. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.3 | current |
| geXcvrMismatchClear NOTIFICATION-TYPE A previously active GE Mistmatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.4 | current |
| geOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the Gigabit Ethernet facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.5 | current |
| geOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active GE minimum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.6 | current |
| geOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the Gigabity Ethernet facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.7 | current |
| geOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active GE maximum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.8 | current |
| geOpticalPwrTransmittedMinCond NOTIFICATION-TYPE Indicates that the output power for the Gigabit Ethernet facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.9 | current |
| geOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active GE minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.10 | current |
| geOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE Indicates that the output power for the Gigabit Ethernet facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.11 | current |
| geOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active GE maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.12 | current |
| geLossOfSyncCond NOTIFICATION-TYPE A Gigabit Ethernet Loss of Synchronization condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.13 | current |
| geLossOfSyncClear NOTIFICATION-TYPE A previously active Gigabit Ethernet Loss of Synchronization condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.14 | current |
| geRemotePathFailureCond NOTIFICATION-TYPE A Gigabit Ethernet Remote Path Failure condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.15 | current |
| geRemotePathFailureClear NOTIFICATION-TYPE A previously active GE Remote Path Failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.16 | current |
| geLossOfMultiframeCond NOTIFICATION-TYPE A Loss of Multiframe condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.17 | current |
| geLossOfMultiframeClear NOTIFICATION-TYPE A previously raised GE Loss of Multiframe condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.18 | current |
| geLossOfSequenceCond NOTIFICATION-TYPE A Loss of Sequence condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.19 | current |
| geLossOfSequenceClear NOTIFICATION-TYPE A previously active GE Loss of Sequence condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.20 | current |
| geLossOfAlignmentCond NOTIFICATION-TYPE A Loss of Alignment condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.21 | current |
| geLossOfAlignmentClear NOTIFICATION-TYPE A previously active GE Loss of Alignment condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.22 | current |
| geLoopbackCond NOTIFICATION-TYPE Indicates that the Gigabit Ethernet facility has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.23 | current |
| geLoopbackClear NOTIFICATION-TYPE A previously active GE Loopback condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.24 | current |
| geBandwidthMismatchCond NOTIFICATION-TYPE A GE bandwidth mismatch condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.25 | current |
| geBandwidthMismatchClear NOTIFICATION-TYPE A previously active GE bandwidth mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.26 | current |
| gePayloadMismatchCond NOTIFICATION-TYPE A GE payload mismatch condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.27 | current |
| gePayloadMismatchClear NOTIFICATION-TYPE A previously active GE payload mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.16.0.28 | current |
| fcLossOfSignalCond NOTIFICATION-TYPE This notification indicates that there is no input signal detected on the Fiber Channel port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.1 | current |
| fcLossOfSignalClear NOTIFICATION-TYPE This notification indicates that a previously active FC Loss of Signal condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.2 | current |
| fcXcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for the Fiber Channel facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the FC facility. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.3 | current |
| fcXcvrMismatchClear NOTIFICATION-TYPE A previously active FC XCVR Mistmatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.4 | current |
| fcOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the Fiber Channel facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.5 | current |
| fcOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active FC minimum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.6 | current |
| fcOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the Fiber Channel facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.7 | current |
| fcOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active FC maximum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.8 | current |
| fcOpticalPwrTransmittedMinCond NOTIFICATION-TYPE Indicates that the output power for the Fiber Channel facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.9 | current |
| fcOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active FC minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.10 | current |
| fcOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE Indicates that the output power for the Fiber Channel facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.11 | current |
| fcOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active FC maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.12 | current |
| fcLossOfSyncCond NOTIFICATION-TYPE A Fiber Channel Loss of Synchronization condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.13 | current |
| fcLossOfSyncClear NOTIFICATION-TYPE A previously active Fiber Channel Loss of Synchronization condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.14 | current |
| fcRemotePathFailureCond NOTIFICATION-TYPE A Fiber Channel Remote Path Failure condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.15 | current |
| fcRemotePathFailureClear NOTIFICATION-TYPE A previously active FC Remote Path Failure condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.16 | current |
| fcLossOfMultiframeCond NOTIFICATION-TYPE A Loss of Multiframe condition is active against the VCG that is mapped to the identified Fiber Channel port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.17 | current |
| fcLossOfMultiframeClear NOTIFICATION-TYPE A previously raised FC Loss of Multiframe condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.18 | current |
| fcLossOfSequenceCond NOTIFICATION-TYPE A Loss of Sequence condition is active against the VCG that is mapped to the identified Fiber Channel port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.19 | current |
| fcLossOfSequenceClear NOTIFICATION-TYPE A previously active FC Loss of Sequence condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.20 | current |
| fcLossOfAlignmentCond NOTIFICATION-TYPE A Loss of Alignment condition is active against the VCG that is mapped to the identified Fiber Channel port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.21 | current |
| fcLossOfAlignmentClear NOTIFICATION-TYPE A previously active FC Loss of Alignment condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.22 | current |
| fcLoopbackCond NOTIFICATION-TYPE Indicates that the Fiber Channel facility has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.23 | current |
| fcLoopbackClear NOTIFICATION-TYPE A previously active FC Loopback condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.24 | current |
| fcBandwidthMismatchCond NOTIFICATION-TYPE A Fiber Channel bandwidth mismatch condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.25 | current |
| fcBandwidthMismatchClear NOTIFICATION-TYPE A previously active Fiber Channel bandwidth mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.26 | current |
| fcPayloadMismatchCond NOTIFICATION-TYPE A Fiber Channel payload mismatch condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.27 | current |
| fcPayloadMismatchClear NOTIFICATION-TYPE A previously active Fiber Channel payload mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.17.0.28 | current |
| olsSFPMissingCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.1 | current |
| olsSFPMissingClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.2 | current |
| olsSFPMismatchCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.3 | current |
| olsSFPMismatchClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.4 | current |
| olsInputLOSCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.5 | current |
| olsInputLOSClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.6 | current |
| olsOpticalPwrReceivedMinCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.7 | current |
| olsOpticalPwrReceivedMinClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.8 | current |
| olsOpticalPwrReceivedMaxCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.9 | current |
| olsOpticalPwrReceivedMaxClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.10 | current |
| olsOpticalPwrTransmittedMinCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.11 | current |
| olsOpticalPwrTransmittedMinClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.12 | current |
| olsOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.13 | current |
| olsOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.14 | current |
| olsTemperatureMaxCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.15 | current |
| olsTemperatureMaxClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.16 | current |
| olsLoopbackCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.17 | current |
| olsLoopbackClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.18 | current |
| olsLossOfSyncCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.19 | current |
| olsLossOfSyncClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.20 | current |
| olsLossOfFrameCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.21 | current |
| olsLossOfFrameClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.22 | current |
| olsAlarmIndicationSignalCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.23 | current |
| olsAlarmIndicationSignalClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.24 | current |
| olsBackwardDefectIndicatorCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.25 | current |
| olsBackwardDefectIndicatorClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.26 | current |
| olsSignalDegradeCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.27 | current |
| olsSignalDegradeClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.28 | current |
| olsOTNPayloadMismatchCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.29 | current |
| olsOTNPayloadMismatchClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.30 | current |
| olsOTUTrailTraceMismatchCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.31 | current |
| olsOTUTrailTraceMismatchClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.32 | current |
| olsRemoteFaultCond NOTIFICATION-TYPE A remote fault indication is active on the ethernet interface. | 1.3.6.1.4.1.18070.2.2.2.2.20.0.33 | current |
| olsRemoteFaultClear NOTIFICATION-TYPE A previously raised remote fault indication has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.20.0.34 | current |
| olsLocalFaultCond NOTIFICATION-TYPE A local fault indication is active on the ethernet interface. | 1.3.6.1.4.1.18070.2.2.2.2.20.0.35 | current |
| olsLocalFaultClear NOTIFICATION-TYPE A previously raised local fault indication has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.20.0.36 | current |
| olsWavelengthNotAchievableCond NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.37 | current |
| olsWavelengthNotAchievableClear NOTIFICATION-TYPE | 1.3.6.1.4.1.18070.2.2.2.2.20.0.38 | current |
| olsLinkDownCond NOTIFICATION-TYPE PVX L2 port link down. | 1.3.6.1.4.1.18070.2.2.2.2.21.0.1 | current |
| olsLinkDownClear NOTIFICATION-TYPE PVX L2 port link down has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.21.0.2 | current |
| odunPayloadMismatchCond NOTIFICATION-TYPE A payload mismatch is active on the ODU-N facility. | 1.3.6.1.4.1.18070.2.2.2.2.24.0.1 | current |
| odunPayloadMismatchClear NOTIFICATION-TYPE A previously active ODU-N facility payload mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.24.0.2 | current |
| odunOpenConnectionIndicatorCond NOTIFICATION-TYPE An OCI is active on the ODU-N facility. | 1.3.6.1.4.1.18070.2.2.2.2.24.0.3 | current |
| odunOpenConnectionIndicatorClear NOTIFICATION-TYPE A previously active ODU-N OCI condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.24.0.4 | current |
| briLossOfSignalCond NOTIFICATION-TYPE This notification indicates that there is no input signal detected on the BRI port. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.1 | current |
| briLossOfSignalClear NOTIFICATION-TYPE This notification indicates that a previously active BRI Loss of Signal condition has been cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.2 | current |
| briXcvrMismatchCond NOTIFICATION-TYPE There is a mismatch between the SFP or XFP transceiver provisioned for the BRI facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the BRI facility. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.3 | current |
| briXcvrMismatchClear NOTIFICATION-TYPE A previously active BRI XCVR Mistmatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.4 | current |
| briOpticalPwrReceivedMinCond NOTIFICATION-TYPE Indicates that the input power for the BRI facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.5 | current |
| briOpticalPwrReceivedMinClear NOTIFICATION-TYPE A previously active BRI minimum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.6 | current |
| briOpticalPwrReceivedMaxCond NOTIFICATION-TYPE Indicates that the input power for the BRI facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.7 | current |
| briOpticalPwrReceivedMaxClear NOTIFICATION-TYPE A previously active BRI maximum power recieved condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.8 | current |
| briOpticalPwrTransmittedMinCond NOTIFICATION-TYPE Indicates that the output power for the BRI facility has fallen below the minimum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.9 | current |
| briOpticalPwrTransmittedMinClear NOTIFICATION-TYPE A previously active BRI minimum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.10 | current |
| briOpticalPwrTransmittedMaxCond NOTIFICATION-TYPE Indicates that the output power for the BRI facility has risen above the maximum threshold. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.11 | current |
| briOpticalPwrTransmittedMaxClear NOTIFICATION-TYPE A previously active BRI maximum power transmitted condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.12 | current |
| briLossOfMultiframeCond NOTIFICATION-TYPE A Loss of Multiframe condition is active against the VCG that is mapped to the identified BRI port. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.13 | current |
| briLossOfMultiframeClear NOTIFICATION-TYPE A previously raised BRI Loss of Multiframe condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.14 | current |
| briLossOfSequenceCond NOTIFICATION-TYPE A Loss of Sequence condition is active against the VCG that is mapped to the identified BRI port. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.15 | current |
| briLossOfSequenceClear NOTIFICATION-TYPE A previously active BRI Loss of Sequence condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.16 | current |
| briLossOfAlignmentCond NOTIFICATION-TYPE A Loss of Alignment condition is active against the VCG that is mapped to the identified BRI port. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.17 | current |
| briLossOfAlignmentClear NOTIFICATION-TYPE A previously active BRI Loss of Alignment condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.18 | current |
| briLoopbackCond NOTIFICATION-TYPE Indicates that the BRI facility has been provisioned to enter loopback mode. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.19 | current |
| briLoopbackClear NOTIFICATION-TYPE A previously active BRI Loopback condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.20 | current |
| briBandwidthMismatchCond NOTIFICATION-TYPE A BRI bandwidth mismatch condition is active on the port. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.21 | current |
| briBandwidthMismatchClear NOTIFICATION-TYPE A previously active BRI bandwidth mismatch condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.22 | current |
| briLossOfLockCond NOTIFICATION-TYPE This alarm indicates that a BRI port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.23 | current |
| briLossOfLockClear NOTIFICATION-TYPE A previously active BRI loss of lock condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.24 | current |
| briTxLockingCond NOTIFICATION-TYPE This alarm indicates that a BRI client port is in the process of locking on the signal in the transmit direction. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.25 | current |
| briTxLockingClear NOTIFICATION-TYPE A previously active BRI TX locking condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.25.0.26 | current |
| ntpAssocSrvrNotReachableCond NOTIFICATION-TYPE This alarm indicates that an NTP server can not be reached. This is a result of either: an invalid IP address, network problems or the server is down. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.1 | current |
| ntpAssocSrvrNotReachableClear NOTIFICATION-TYPE A previously active NTP server not reachable condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.2 | current |
| ntpAssocSrvrNotRespondingCond NOTIFICATION-TYPE This alarm indicates that an NTP server is reachable but is not responding to the NTP requests correctly. This can be a result of either: the server does not have the service running or there is a server is having problems. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.3 | current |
| ntpAssocSrvrNotRespondingClear NOTIFICATION-TYPE A previously active NTP server not responding condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.4 | current |
| ntpAssocAuthenFailedCond NOTIFICATION-TYPE This alarm indicates that NTP authentication has failed. This can be a result of either: the key is configured incorrectly on the client side or the NTP server does not accept the key. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.5 | current |
| ntpAssocAuthenFailedClear NOTIFICATION-TYPE A previously active NTP authentication failed condition has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.26.0.6 | current |
| envAttrUnsupportedCond NOTIFICATION-TYPE Indicates that an environmental alarm detection is configured against a housekeeping input port which is located on equipment which does not support the configured function. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.1 | current |
| envAttrUnsupportedClear NOTIFICATION-TYPE A previously active environmental attribute unsupported alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.2 | current |
| envAirComprCond NOTIFICATION-TYPE Indicates that an environmental air compressor failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.3 | current |
| envAirComprClear NOTIFICATION-TYPE A previously active environmental air compressor failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.4 | current |
| envAirCondCond NOTIFICATION-TYPE Indicates that an environmental air conditioning failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.5 | current |
| envAirCondClear NOTIFICATION-TYPE A previously active environmental air conditioning failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.6 | current |
| envAirDryrCond NOTIFICATION-TYPE Indicates that an environmental air dryer failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.7 | current |
| envAirDryrClear NOTIFICATION-TYPE A previously active environmental air dryer failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.8 | current |
| envBatDschrdCond NOTIFICATION-TYPE Indicates that an environmental battery discharging alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.9 | current |
| envBatDschrdClear NOTIFICATION-TYPE A previously active environmental battery discharging alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.10 | current |
| envBatteryCond NOTIFICATION-TYPE Indicates that an environmental battery failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.11 | current |
| envBatteryClear NOTIFICATION-TYPE A previously active environmental battery failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.12 | current |
| envClFanCond NOTIFICATION-TYPE Indicates that an environmental cooling fan failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.13 | current |
| envClFanClear NOTIFICATION-TYPE A previously active environmental cooling fan failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.14 | current |
| envCpMajorCond NOTIFICATION-TYPE Indicates that an environmental centralized power major alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.15 | current |
| envCpMajorClear NOTIFICATION-TYPE A previously active environmental centralized power major alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.16 | current |
| envCpMinorCond NOTIFICATION-TYPE Indicates that an environmental centralized power minor alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.17 | current |
| envCpMinorClear NOTIFICATION-TYPE A previously active environmental centralized power minor alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.18 | current |
| envDoorOpenCond NOTIFICATION-TYPE Indicates that an environmental door open alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.19 | current |
| envDoorOpenClear NOTIFICATION-TYPE A previously active environmental door open alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.20 | current |
| envEngineCond NOTIFICATION-TYPE Indicates that an environmental engine failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.21 | current |
| envEngineClear NOTIFICATION-TYPE A previously active environmental engine failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.22 | current |
| envEngOprgCond NOTIFICATION-TYPE Indicates that an environmental engine operating alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.23 | current |
| envEngOprgClear NOTIFICATION-TYPE A previously active environmental engine operating alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.24 | current |
| envExplGsCond NOTIFICATION-TYPE Indicates that an environmental explosive gas alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.25 | current |
| envExplGsClear NOTIFICATION-TYPE A previously active environmental explosive gas alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.26 | current |
| envFirDetrCond NOTIFICATION-TYPE Indicates that an environmental fire detector failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.27 | current |
| envFirDetrClear NOTIFICATION-TYPE A previously active environmental fire detector failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.28 | current |
| envFireCond NOTIFICATION-TYPE Indicates that an environmental fire alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.29 | current |
| envFireClear NOTIFICATION-TYPE A previously active environmental fire alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.30 | current |
| envFloodCond NOTIFICATION-TYPE Indicates that an environmental flood alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.31 | current |
| envFloodClear NOTIFICATION-TYPE A previously active environmental flood alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.32 | current |
| envFuseCond NOTIFICATION-TYPE Indicates that an environmental fuse alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.33 | current |
| envFuseClear NOTIFICATION-TYPE A previously active environmental fuse alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.34 | current |
| envGenCond NOTIFICATION-TYPE Indicates that an environmental generator failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.35 | current |
| envGenClear NOTIFICATION-TYPE A previously active environmental generator failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.36 | current |
| envGenericCond NOTIFICATION-TYPE Indicates that an environmental generic alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.37 | current |
| envGenericClear NOTIFICATION-TYPE A previously active environmental generic alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.38 | current |
| envHiAirCond NOTIFICATION-TYPE Indicates that an environmental high airflow alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.39 | current |
| envHiAirClear NOTIFICATION-TYPE A previously active environmental high airflow alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.40 | current |
| envHiHumCond NOTIFICATION-TYPE Indicates that an environmental high humidity alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.41 | current |
| envHiHumClear NOTIFICATION-TYPE A previously active environmental high humidity alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.42 | current |
| envHiTempCond NOTIFICATION-TYPE Indicates that an environmental high temperature alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.43 | current |
| envHiTempClear NOTIFICATION-TYPE A previously active environmental high temperature alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.44 | current |
| envHiWindCond NOTIFICATION-TYPE Indicates that an environmental high wind alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.45 | current |
| envHiWindClear NOTIFICATION-TYPE A previously active environmental high wind alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.46 | current |
| envHiWtrCond NOTIFICATION-TYPE Indicates that an environmental high water alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.47 | current |
| envHiWtrClear NOTIFICATION-TYPE A previously active environmental high water alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.48 | current |
| envIceBuildupCond NOTIFICATION-TYPE Indicates that an environmental ice buildup alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.49 | current |
| envIceBuildupClear NOTIFICATION-TYPE A previously active environmental ice buildup alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.50 | current |
| envIntruderCond NOTIFICATION-TYPE Indicates that an environmental intrusion alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.51 | current |
| envIntruderClear NOTIFICATION-TYPE A previously active environmental intrusion alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.52 | current |
| envLwBatvgCond NOTIFICATION-TYPE Indicates that an environmental low battery voltage alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.53 | current |
| envLwBatvgClear NOTIFICATION-TYPE A previously active environmental low battery voltage alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.54 | current |
| envLwFuelCond NOTIFICATION-TYPE Indicates that an environmental low fuel alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.55 | current |
| envLwFuelClear NOTIFICATION-TYPE A previously active environmental low fuel alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.56 | current |
| envLwHumCond NOTIFICATION-TYPE Indicates that an environmental low humidity alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.57 | current |
| envLwHumClear NOTIFICATION-TYPE A previously active environmental low humidity alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.58 | current |
| envLwPresCond NOTIFICATION-TYPE Indicates that an environmental low cable pressure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.59 | current |
| envLwPresClear NOTIFICATION-TYPE A previously active environmental low cable pressure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.60 | current |
| envLwTempCond NOTIFICATION-TYPE Indicates that an environmental low temperature alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.61 | current |
| envLwTempClear NOTIFICATION-TYPE A previously active environmental low temperature alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.62 | current |
| envLwWtrCond NOTIFICATION-TYPE Indicates that an environmental low water alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.63 | current |
| envLwWtrClear NOTIFICATION-TYPE A previously active environmental low water alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.64 | current |
| envMiscCond NOTIFICATION-TYPE Indicates that an environmental miscellaneous alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.65 | current |
| envMiscClear NOTIFICATION-TYPE A previously active environmental miscellaneous alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.66 | current |
| envOpenDrCond NOTIFICATION-TYPE Indicates that an environmental open door alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.67 | current |
| envOpenDrClear NOTIFICATION-TYPE A previously active environmental open door alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.68 | current |
| envPowerCond NOTIFICATION-TYPE Indicates that an environmental power failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.69 | current |
| envPowerClear NOTIFICATION-TYPE A previously active environmental power failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.70 | current |
| envPumpCond NOTIFICATION-TYPE Indicates that an environmental pump failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.71 | current |
| envPumpClear NOTIFICATION-TYPE A previously active environmental pump failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.72 | current |
| envRectCond NOTIFICATION-TYPE Indicates that an environmental rectifier failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.73 | current |
| envRectClear NOTIFICATION-TYPE A previously active environmental rectifier failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.74 | current |
| envRectHiCond NOTIFICATION-TYPE Indicates that an environmental rectifier high voltage alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.75 | current |
| envRectHiClear NOTIFICATION-TYPE A previously active environmental rectifier high voltage alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.76 | current |
| envRectLoCond NOTIFICATION-TYPE Indicates that an environmental rectifier low voltage alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.77 | current |
| envRectLoClear NOTIFICATION-TYPE A previously active environmental rectifier low voltage alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.78 | current |
| envSmokeCond NOTIFICATION-TYPE Indicates that an environmental smoke alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.79 | current |
| envSmokeClear NOTIFICATION-TYPE A previously active environmental smoke alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.80 | current |
| envToxicGasCond NOTIFICATION-TYPE Indicates that an environmental toxic gas alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.81 | current |
| envToxicGasClear NOTIFICATION-TYPE A previously active environmental toxic gas alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.82 | current |
| envVentnCond NOTIFICATION-TYPE Indicates that an environmental ventilation system failure alarm is raised. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.83 | current |
| envVentnClear NOTIFICATION-TYPE A previously active environmental ventilation system failure alarm has cleared. | 1.3.6.1.4.1.18070.2.2.2.2.27.0.84 | current |
| dbChangeEvt NOTIFICATION-TYPE This message indicates that a change has been made in the value of the provisioned object identified by the dbChangeOID Var-Bind. If multiple objects have been changed in the same transaction, there will be multiple occurrances of the dbChangeOID object listed in the Var-Bind list. | 1.3.6.1.4.1.18070.2.2.2.3.0.2 | current |
| dbChangeSecuEvt NOTIFICATION-TYPE This message indicates that a change has been made in the value of the SNMP community string, SNMP trap reciever, or Tl1User. | 1.3.6.1.4.1.18070.2.2.2.3.0.3 | current |