MIBs Depot

ALARM-MIB

Registered at
1.3.6.1.2.1.118
Last updated
2004-09-09 00:00
Organization
IETF Distributed Management Working Group
Revisions
2004-09-09 00:00
Namespace
standard
Source file
ALARM-MIB
Digest
sha256:8457e78359e350e656b9cf15b58f1df940ab52dc48bfd40efda30a924e7dba6c

Description

The MIB module describes a generic solution to model alarms and to store the current list of active alarms. Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3877. For full legal notices see the RFC itself. Supplementary information may be available on: http://www.ietf.org/copyrights/ianamib.html

Contact

WG EMail: disman@ietf.org Subscribe: disman-request@ietf.org http://www.ietf.org/html.charters/disman-charter.html Chair: Randy Presuhn randy_presuhn@mindspring.com Editors: Sharon Chisholm Nortel Networks PO Box 3511 Station C Ottawa, Ont. K1Y 4H7 Canada schishol@nortelnetworks.com Dan Romascanu Avaya Atidim Technology Park, Bldg. #3 Tel Aviv, 61131 Israel Tel: +972-3-645-8414 Email: dromasca@avaya.com

Imports

FromSymbols
INET-ADDRESS-MIBInetAddress, InetAddressType
RMON2-MIBZeroBasedCounter32
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Opaque, TimeTicks, Unsigned32, iso, mib-2, zeroDotZero
SNMPv2-TCDateAndTime, DisplayString, RowPointer, RowStatus, TEXTUAL-CONVENTION

Imported by

5 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ALARM-MIB
IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB

Textual conventions

NameOIDSyntaxAccessStatus
LocalSnmpEngineOrZeroLenStr
TEXTUAL-CONVENTION
An SNMP Engine ID or a zero-length string. The instantiation of this textual convention will provide guidance on when this will be an SNMP Engine ID and when it will be a zero lengths string
current
ResourceId
TEXTUAL-CONVENTION
A unique identifier for this resource. The type of the resource can be determined by looking at the OID that describes the resource. Resources must be identified in a consistent manner. For example, if this resource is an interface, this object MUST point to an ifIndex and if this resource is a physical entity [RFC2737], then this MUST point to an entPhysicalDescr, given that entPhysicalIndex is not accessible. In general, the value is the name of the instance of the first accessible columnar object in the conceptual row of a table that is meaningful for this resource type, which SHOULD be defined in an IETF standard MIB.
current

Objects

NameOIDSyntaxAccessStatus
alarmNotifications
OBJECT-IDENTITY
1.3.6.1.2.1.118.0
alarmObjects
OBJECT-IDENTITY
1.3.6.1.2.1.118.1
alarmModel
OBJECT-IDENTITY
1.3.6.1.2.1.118.1.1
alarmModelLastChanged
OBJECT-TYPE
The value of sysUpTime at the time of the last creation, deletion or modification of an entry in the alarmModelTable. If the number and content of entries has been unchanged since the last re-initialization of the local network management subsystem, then the value of this object MUST be zero.
1.3.6.1.2.1.118.1.1.1TimeTicksread-onlycurrent
alarmModelTable
OBJECT-TYPE
A table of information about possible alarms on the system, and how they have been modelled.
1.3.6.1.2.1.118.1.1.2not-accessiblecurrent
alarmModelEntry
OBJECT-TYPE
Entries appear in this table for each possible alarm state. This table MUST be persistent across system reboots.
1.3.6.1.2.1.118.1.1.2.1not-accessiblecurrent
alarmModelIndex
OBJECT-TYPE
An integer that acts as an alarm Id to uniquely identify each alarm within the named alarm list.
1.3.6.1.2.1.118.1.1.2.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
alarmModelState
OBJECT-TYPE
A value of 1 MUST indicate a clear alarm state. The value of this object MUST be less than the alarmModelState of more severe alarm states for this alarm. The value of this object MUST be more than the alarmModelState of less severe alarm states for this alarm.
1.3.6.1.2.1.118.1.1.2.1.2Unsigned32 (1..4294967295)not-accessiblecurrent
alarmModelNotificationId
OBJECT-TYPE
The NOTIFICATION-TYPE object identifier of this alarm state transition. If there is no notification associated with this alarm state, the value of this object MUST be '0.0'
1.3.6.1.2.1.118.1.1.2.1.3OBJECT IDENTIFIERread-createcurrent
alarmModelVarbindIndex
OBJECT-TYPE
The index into the varbind listing of the notification indicated by alarmModelNotificationId which helps signal that the given alarm has changed state. If there is no applicable varbind, the value of this object MUST be zero. Note that the value of alarmModelVarbindIndex acknowledges the existence of the first two obligatory varbinds in the InformRequest-PDU and SNMPv2-Trap-PDU (sysUpTime.0 and snmpTrapOID.0). That is, a value of 2 refers to the snmpTrapOID.0. If the incoming notification is instead an SNMPv1 Trap-PDU, then an appropriate value for sysUpTime.0 or snmpTrapOID.0 shall be determined by using the rules in section 3.1 of [RFC3584]
1.3.6.1.2.1.118.1.1.2.1.4Unsigned32read-createcurrent
alarmModelVarbindValue
OBJECT-TYPE
The value that the varbind indicated by alarmModelVarbindIndex takes to indicate that the alarm has entered this state. If alarmModelVarbindIndex has a value of 0, so MUST alarmModelVarbindValue.
1.3.6.1.2.1.118.1.1.2.1.5Integer32read-createcurrent
alarmModelDescription
OBJECT-TYPE
A brief description of this alarm and state suitable to display to operators.
1.3.6.1.2.1.118.1.1.2.1.6SnmpAdminStringread-createcurrent
alarmModelSpecificPointer
OBJECT-TYPE
If no additional, model-specific Alarm MIB is supported by the system the value of this object is `0.0'and attempts to set it to any other value MUST be rejected appropriately. When a model-specific Alarm MIB is supported, this object MUST refer to the first accessible object in a corresponding row of the model definition in one of these model-specific MIB and attempts to set this object to { 0 0 } or any other value MUST be rejected appropriately.
1.3.6.1.2.1.118.1.1.2.1.7RowPointerread-createcurrent
alarmModelVarbindSubtree
OBJECT-TYPE
The name portion of each VarBind in the notification, in order, is compared to the value of this object. If the name is equal to or a subtree of the value of this object, for purposes of computing the value of AlarmActiveResourceID the 'prefix' will be the matching portion, and the 'indexes' will be any remainder. The examination of varbinds ends with the first match. If the value of this object is 0.0, then the first varbind, or in the case of v2, the first varbind after the timestamp and the trap OID, will always be matched.
1.3.6.1.2.1.118.1.1.2.1.8OBJECT IDENTIFIERread-createcurrent
alarmModelResourcePrefix
OBJECT-TYPE
The value of AlarmActiveResourceId is computed by appending any indexes extracted in accordance with the description of alarmModelVarbindSubtree onto the value of this object. If this object's value is 0.0, then the 'prefix' extracted is used instead.
1.3.6.1.2.1.118.1.1.2.1.9OBJECT IDENTIFIERread-createcurrent
alarmModelRowStatus
OBJECT-TYPE
Control for creating and deleting entries. Entries may be modified while active. Alarms whose alarmModelRowStatus is not active will not appear in either the alarmActiveTable or the alarmClearTable. Setting this object to notInService cannot be used as an alarm suppression mechanism. Entries that are notInService will disappear as described in RFC2579. This row can not be modified while it is being referenced by a value of alarmActiveModelPointer. In these cases, an error of `inconsistentValue' will be returned to the manager. This entry may be deleted while it is being referenced by a value of alarmActiveModelPointer. This results in the deletion of this entry and entries in the active alarms referencing this entry via an alarmActiveModelPointer. As all read-create objects in this table have a DEFVAL clause, there is no requirement that any object be explicitly set before this row can become active. Note that a row consisting only of default values is not very meaningful.
1.3.6.1.2.1.118.1.1.2.1.10RowStatusread-createcurrent
alarmActive
OBJECT-IDENTITY
1.3.6.1.2.1.118.1.2
alarmActiveLastChanged
OBJECT-TYPE
The value of sysUpTime at the time of the last creation or deletion of an entry in the alarmActiveTable. If the number of entries has been unchanged since the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.2.1.118.1.2.1TimeTicksread-onlycurrent
alarmActiveTable
OBJECT-TYPE
A table of Active Alarms entries.
1.3.6.1.2.1.118.1.2.2not-accessiblecurrent
alarmActiveEntry
OBJECT-TYPE
Entries appear in this table when alarms are raised. They are removed when the alarm is cleared. If under extreme resource constraint the system is unable to add any more entries into this table, then the alarmActiveOverflow statistic will be increased by one.
1.3.6.1.2.1.118.1.2.2.1not-accessiblecurrent
alarmListName
OBJECT-TYPE
The name of the list of alarms. This SHOULD be the same as nlmLogName if the Notification Log MIB [RFC3014] is supported. This SHOULD be the same as, or contain as a prefix, the applicable snmpNotifyFilterProfileName if the SNMP-NOTIFICATION-MIB DEFINITIONS [RFC3413] is supported. An implementation may allow multiple named alarm lists, up to some implementation-specific limit (which may be none). A zero-length list name is reserved for creation and deletion by the managed system, and MUST be used as the default log name by systems that do not support named alarm lists.
1.3.6.1.2.1.118.1.2.2.1.1SnmpAdminString (SIZE(0..32))not-accessiblecurrent
alarmActiveDateAndTime
OBJECT-TYPE
The local date and time when the error occurred. This object facilitates retrieving all instances of alarms that have been raised or have changed state since a given point in time. Implementations MUST include the offset from UTC, if available. Implementation in environments in which the UTC offset is not available is NOT RECOMMENDED.
1.3.6.1.2.1.118.1.2.2.1.2DateAndTimenot-accessiblecurrent
alarmActiveIndex
OBJECT-TYPE
A strictly monotonically increasing integer which acts as the index of entries within the named alarm list. It wraps back to 1 after it reaches its maximum value.
1.3.6.1.2.1.118.1.2.2.1.3Unsigned32 (1..4294967295)not-accessiblecurrent
alarmActiveEngineID
OBJECT-TYPE
The identification of the SNMP engine at which the alarm originated. If the alarm is from an SNMPv1 system this object is a zero length string.
1.3.6.1.2.1.118.1.2.2.1.4LocalSnmpEngineOrZeroLenStrread-onlycurrent
alarmActiveEngineAddressType
OBJECT-TYPE
This object indicates what type of address is stored in the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc.
1.3.6.1.2.1.118.1.2.2.1.5InetAddressTyperead-onlycurrent
alarmActiveEngineAddress
OBJECT-TYPE
The address of the SNMP engine on which the alarm is occurring. This object MUST always be instantiated, even if the list can contain alarms from only one engine.
1.3.6.1.2.1.118.1.2.2.1.6InetAddressread-onlycurrent
alarmActiveContextName
OBJECT-TYPE
The name of the SNMP MIB context from which the alarm came. For SNMPv1 alarms this is the community string from the Trap. Note that care MUST be taken when selecting community strings to ensure that these can be represented as a well-formed SnmpAdminString. Community or Context names that are not well-formed SnmpAdminStrings will be mapped to zero length strings. If the alarm's source SNMP engine is known not to support multiple contexts, this object is a zero length string.
1.3.6.1.2.1.118.1.2.2.1.7SnmpAdminString (SIZE(0..32))read-onlycurrent
alarmActiveVariables
OBJECT-TYPE
The number of variables in alarmActiveVariableTable for this alarm.
1.3.6.1.2.1.118.1.2.2.1.8Unsigned32read-onlycurrent
alarmActiveNotificationID
OBJECT-TYPE
The NOTIFICATION-TYPE object identifier of the alarm state transition that is occurring.
1.3.6.1.2.1.118.1.2.2.1.9OBJECT IDENTIFIERread-onlycurrent
alarmActiveResourceId
OBJECT-TYPE
This object identifies the resource under alarm. If there is no corresponding resource, then the value of this object MUST be 0.0.
1.3.6.1.2.1.118.1.2.2.1.10ResourceIdread-onlycurrent
alarmActiveDescription
OBJECT-TYPE
This object provides a textual description of the active alarm. This text is generated dynamically by the notification generator to provide useful information to the human operator. This information SHOULD provide information allowing the operator to locate the resource for which this alarm is being generated. This information is not intended for consumption by automated tools.
1.3.6.1.2.1.118.1.2.2.1.11SnmpAdminStringread-onlycurrent
alarmActiveLogPointer
OBJECT-TYPE
A pointer to the corresponding row in a notification logging MIB where the state change notification for this active alarm is logged. If no log entry applies to this active alarm, then this object MUST have the value of 0.0
1.3.6.1.2.1.118.1.2.2.1.12RowPointerread-onlycurrent
alarmActiveModelPointer
OBJECT-TYPE
A pointer to the corresponding row in the alarmModelTable for this active alarm. This points not only to the alarm model being instantiated, but also to the specific alarm state that is active.
1.3.6.1.2.1.118.1.2.2.1.13RowPointerread-onlycurrent
alarmActiveSpecificPointer
OBJECT-TYPE
If no additional, model-specific, Alarm MIB is supported by the system this object is `0.0'. When a model-specific Alarm MIB is supported, this object is the instance pointer to the specific model-specific active alarm list.
1.3.6.1.2.1.118.1.2.2.1.14RowPointerread-onlycurrent
alarmActiveVariableTable
OBJECT-TYPE
A table of variables to go with active alarm entries.
1.3.6.1.2.1.118.1.2.3not-accessiblecurrent
alarmActiveVariableEntry
OBJECT-TYPE
Entries appear in this table when there are variables in the varbind list of a corresponding alarm in alarmActiveTable. Entries appear in this table as though the trap/notification had been transported using a SNMPv2-Trap-PDU, as defined in [RFC3416] - i.e., the alarmActiveVariableIndex 1 will always be sysUpTime and alarmActiveVariableIndex 2 will always be snmpTrapOID. If the incoming notification is instead an SNMPv1 Trap-PDU and the value of alarmModelVarbindIndex is 1 or 2, an appropriate value for sysUpTime.0 or snmpTrapOID.0 shall be determined by using the rules in section 3.1 of [RFC3584].
1.3.6.1.2.1.118.1.2.3.1not-accessiblecurrent
alarmActiveVariableIndex
OBJECT-TYPE
A strictly monotonically increasing integer, starting at 1 for a given alarmActiveIndex, for indexing variables within the active alarm variable list.
1.3.6.1.2.1.118.1.2.3.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
alarmActiveVariableID
OBJECT-TYPE
The alarm variable's object identifier.
1.3.6.1.2.1.118.1.2.3.1.2OBJECT IDENTIFIERread-onlycurrent
alarmActiveVariableValueType
OBJECT-TYPE
The type of the value. One and only one of the value objects that follow is used for a given row in this table, based on this type.
1.3.6.1.2.1.118.1.2.3.1.3INTEGER {counter32(1), unsigned32(2), timeTicks(3), integer32(4), ipAddress(5), octetString(6), objectId(7), counter64(8), opaque(9)}read-onlycurrent
alarmActiveVariableCounter32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'counter32'.
1.3.6.1.2.1.118.1.2.3.1.4Counter32read-onlycurrent
alarmActiveVariableUnsigned32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'unsigned32'.
1.3.6.1.2.1.118.1.2.3.1.5Unsigned32read-onlycurrent
alarmActiveVariableTimeTicksVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'timeTicks'.
1.3.6.1.2.1.118.1.2.3.1.6TimeTicksread-onlycurrent
alarmActiveVariableInteger32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'integer32'.
1.3.6.1.2.1.118.1.2.3.1.7Integer32read-onlycurrent
alarmActiveVariableOctetStringVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'octetString'.
1.3.6.1.2.1.118.1.2.3.1.8OCTET STRING (SIZE(0..65535))read-onlycurrent
alarmActiveVariableIpAddressVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'ipAddress'.
1.3.6.1.2.1.118.1.2.3.1.9IpAddressread-onlycurrent
alarmActiveVariableOidVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'objectId'.
1.3.6.1.2.1.118.1.2.3.1.10OBJECT IDENTIFIERread-onlycurrent
alarmActiveVariableCounter64Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'counter64'.
1.3.6.1.2.1.118.1.2.3.1.11Counter64read-onlycurrent
alarmActiveVariableOpaqueVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'opaque'. Note that although RFC2578 [RFC2578] forbids the use of Opaque in 'standard' MIB modules, this particular usage is driven by the need to be able to accurately represent any well-formed notification, and justified by the need for backward compatibility.
1.3.6.1.2.1.118.1.2.3.1.12Opaque (SIZE(0..65535))read-onlycurrent
alarmActiveStatsTable
OBJECT-TYPE
This table represents the alarm statistics information.
1.3.6.1.2.1.118.1.2.4not-accessiblecurrent
alarmActiveStatsEntry
OBJECT-TYPE
Statistics on the current active alarms.
1.3.6.1.2.1.118.1.2.4.1not-accessiblecurrent
alarmActiveStatsActiveCurrent
OBJECT-TYPE
The total number of currently active alarms on the system.
1.3.6.1.2.1.118.1.2.4.1.1Gauge32read-onlycurrent
alarmActiveStatsActives
OBJECT-TYPE
The total number of active alarms since system restarted.
1.3.6.1.2.1.118.1.2.4.1.2ZeroBasedCounter32read-onlycurrent
alarmActiveStatsLastRaise
OBJECT-TYPE
The value of sysUpTime at the time of the last alarm raise for this alarm list. If no alarm raises have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.2.1.118.1.2.4.1.3TimeTicksread-onlycurrent
alarmActiveStatsLastClear
OBJECT-TYPE
The value of sysUpTime at the time of the last alarm clear for this alarm list. If no alarm clears have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.2.1.118.1.2.4.1.4TimeTicksread-onlycurrent
alarmActiveOverflow
OBJECT-TYPE
The number of active alarms that have not been put into the alarmActiveTable since system restart as a result of extreme resource constraints.
1.3.6.1.2.1.118.1.2.5Counter32read-onlycurrent
alarmClear
OBJECT-IDENTITY
1.3.6.1.2.1.118.1.3
alarmClearMaximum
OBJECT-TYPE
This object specifies the maximum number of cleared alarms to store in the alarmClearTable. When this number is reached, the cleared alarms with the earliest clear time will be removed from the table.
1.3.6.1.2.1.118.1.3.1Unsigned32read-writecurrent
alarmClearTable
OBJECT-TYPE
This table contains information on cleared alarms.
1.3.6.1.2.1.118.1.3.2not-accessiblecurrent
alarmClearEntry
OBJECT-TYPE
Information on a cleared alarm.
1.3.6.1.2.1.118.1.3.2.1not-accessiblecurrent
alarmClearIndex
OBJECT-TYPE
An integer which acts as the index of entries within the named alarm list. It wraps back to 1 after it reaches its maximum value. This object has the same value as the alarmActiveIndex that this alarm instance had when it was active.
1.3.6.1.2.1.118.1.3.2.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
alarmClearDateAndTime
OBJECT-TYPE
The local date and time when the alarm cleared. This object facilitates retrieving all instances of alarms that have been cleared since a given point in time. Implementations MUST include the offset from UTC, if available. Implementation in environments in which the UTC offset is not available is NOT RECOMMENDED.
1.3.6.1.2.1.118.1.3.2.1.2DateAndTimenot-accessiblecurrent
alarmClearEngineID
OBJECT-TYPE
The identification of the SNMP engine at which the alarm originated. If the alarm is from an SNMPv1 system this object is a zero length string.
1.3.6.1.2.1.118.1.3.2.1.3LocalSnmpEngineOrZeroLenStrread-onlycurrent
alarmClearEngineAddressType
OBJECT-TYPE
This object indicates what type of address is stored in the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc.
1.3.6.1.2.1.118.1.3.2.1.4InetAddressTyperead-onlycurrent
alarmClearEngineAddress
OBJECT-TYPE
The Address of the SNMP engine on which the alarm was occurring. This is used to identify the source of an SNMPv1 trap, since an alarmActiveEngineId cannot be extracted from the SNMPv1 trap PDU. This object MUST always be instantiated, even if the list can contain alarms from only one engine.
1.3.6.1.2.1.118.1.3.2.1.5InetAddressread-onlycurrent
alarmClearContextName
OBJECT-TYPE
The name of the SNMP MIB context from which the alarm came. For SNMPv1 traps this is the community string from the Trap. Note that care needs to be taken when selecting community strings to ensure that these can be represented as a well-formed SnmpAdminString. Community or Context names that are not well-formed SnmpAdminStrings will be mapped to zero length strings. If the alarm's source SNMP engine is known not to support multiple contexts, this object is a zero length string.
1.3.6.1.2.1.118.1.3.2.1.6SnmpAdminString (SIZE(0..32))read-onlycurrent
alarmClearNotificationID
OBJECT-TYPE
The NOTIFICATION-TYPE object identifier of the alarm clear.
1.3.6.1.2.1.118.1.3.2.1.7OBJECT IDENTIFIERread-onlycurrent
alarmClearResourceId
OBJECT-TYPE
This object identifies the resource that was under alarm. If there is no corresponding resource, then the value of this object MUST be 0.0.
1.3.6.1.2.1.118.1.3.2.1.8ResourceIdread-onlycurrent
alarmClearLogIndex
OBJECT-TYPE
This number MUST be the same as the log index of the applicable row in the notification log MIB, if it exists. If no log index applies to the trap, then this object MUST have the value of 0.
1.3.6.1.2.1.118.1.3.2.1.9Unsigned32 (0..4294967295)read-onlycurrent
alarmClearModelPointer
OBJECT-TYPE
A pointer to the corresponding row in the alarmModelTable for this cleared alarm.
1.3.6.1.2.1.118.1.3.2.1.10RowPointerread-onlycurrent
alarmConformance
OBJECT-IDENTITY
1.3.6.1.2.1.118.2
alarmCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.118.2.1
alarmGroups
OBJECT-IDENTITY
1.3.6.1.2.1.118.2.2

Notifications

NameOIDStatus
alarmActiveState
NOTIFICATION-TYPE
An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId. The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are dropped, not queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss.
1.3.6.1.2.1.118.0.2current
alarmClearState
NOTIFICATION-TYPE
An instance of the alarm indicated by alarmActiveModelPointer has been cleared against the entity indicated by alarmActiveResourceId. The agent must throttle the generation of consecutive alarmActiveClear traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are dropped, not queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmClearState notification-events, e.g., due to throttling or transmission loss.
1.3.6.1.2.1.118.0.3current

Conformance

NameOIDStatus
alarmCompliance
MODULE-COMPLIANCE
The compliance statement for systems supporting the Alarm MIB.
1.3.6.1.2.1.118.2.1.1current
alarmModelGroup
OBJECT-GROUP
Alarm model group.
1.3.6.1.2.1.118.2.2.1current
alarmActiveGroup
OBJECT-GROUP
Active Alarm list group.
1.3.6.1.2.1.118.2.2.2current
alarmActiveStatsGroup
OBJECT-GROUP
Active alarm summary group.
1.3.6.1.2.1.118.2.2.3current
alarmClearGroup
OBJECT-GROUP
Cleared alarm group.
1.3.6.1.2.1.118.2.2.4current
alarmNotificationsGroup
NOTIFICATION-GROUP
The collection of notifications that can be used to model alarms for faults lacking pre-existing notification definitions.
1.3.6.1.2.1.118.2.2.6current