ALPHA-NOTIFICATION-MIB
- Registered at
- 1.3.6.1.4.1.7309.1001.3.6.1.4.1.7309.101
- Last updated
- 2017-07-31 00:00
- Organization
- Alpha Technologies Ltd.
- Revisions
- 2017-07-31 00:00, 2015-07-28 00:00, 2015-07-23 00:00, 2015-06-23 00:00
- Namespace
- alpha
- Source file
ALPHA-NOTIFICATION-MIB- Digest
sha256:2aeb7c30fde74f490917194469b26d0f6474ac21670c69c5e66b7effb5cd524d
Description
This MIB defines the notification block(s) available in system controllers.
Contact
Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC V5J 5M4 Canada Tel: 1-604-436-5900 Fax: 1-604-436-1233
Imports
| From | Symbols |
|---|---|
| ALARM-MIB | alarmActiveModelPointer, alarmActiveResourceId, alarmModelDescription |
| ALPHA-RESOURCE-MIB | alpha, componentListReference, componentListStaticName, controllerInfoName |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ALARM-MIB ALPHA-NOTIFICATION-MIB ALPHA-RESOURCE-MIB IANAifType-MIB IF-MIB INET-ADDRESS-MIB RFC1158-MIB RFC1271-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC TOKEN-RING-RMON-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| alphaAlarmNotificationConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7309.100.102 | |||
| alphaAlarmNotificationCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7309.100.102.1 | |||
| alphaAlarmNotificationGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7309.100.102.1.2 | |||
| alphaAlarmNotificationsExtension OBJECT-IDENTITY | 1.3.6.1.4.1.7309.101 | |||
| alarmSeverity OBJECT-TYPE User defined value used for filtering purposes. | 1.3.6.1.4.1.7309.101.1 | Integer32 | read-only | current |
| alarmCustomDescription OBJECT-TYPE User defined value used for filtering purposes. | 1.3.6.1.4.1.7309.101.2 | OCTET STRING | read-only | current |
| alarmPriority OBJECT-TYPE User defined value used for filtering purposes. | 1.3.6.1.4.1.7309.101.3 | OCTET STRING | read-only | current |
| alarmAdditionalInformation OBJECT-TYPE Additional information about the alarm. Each piece of information is separated by 2 colons ::. The following are currently provided - Physical location, in the format bay-shelf-slot-channel (used by LP Module alarms) - What alert is producing this alarm (used by LP Module alarms) | 1.3.6.1.4.1.7309.101.4 | OCTET STRING | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| alphaAlarmActiveState NOTIFICATION-TYPE SNMPv2 notification varbinds start with SysUptime and Notification Oid as the first two in the list by default. The first varbind in this definition would be the third varbind in the raw output of the notification. An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId. The state of the alarm is indicated by the alarmModelState. The description of the alarm along with its source is indicated by the alarmModelDescription and componentListStaticName respectively. componentListSnmpId provides the Id set to the source of the alarm. The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss. | 1.3.6.1.4.1.7309.100.1 | current |
| alphaAlarmClearState NOTIFICATION-TYPE SNMPv2 notification varbinds start with SysUptime and Notification Oid as the first two in the list by default. The first varbind in this definition would be the third varbind in the raw output of the notification. An instance of the alarm indicated by alarmActiveModelPointer has been cleared against the entity indicated by alarmActiveResourceId. The state of the alarm is indicated by the alarmModelState. The description of the alarm along with its source is indicated by the alarmModelDescription and componentListStaticName respectively. componentListSnmpId provides the Id set to the source of the alarm. The agent must throttle the generation of consecutive alarmActiveClear traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmClearState notification-events, e.g., due to throttling or transmission loss. | 1.3.6.1.4.1.7309.100.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| alphaAlarmNotificationCompliance MODULE-COMPLIANCE The compliance statement for systems supporting the alpha MIB. | 1.3.6.1.4.1.7309.100.102.1.1 | current |
| alphaParameterGroup OBJECT-GROUP Active alpha list group. | 1.3.6.1.4.1.7309.100.102.1.2.1 | current |
| alphaNotificationsGroup NOTIFICATION-GROUP The collection of notifications that can be used to model alarms for faults lacking pre-existing notification definitions. | 1.3.6.1.4.1.7309.100.102.1.2.2 | current |