SCTE-HMS-HEADENDIDENT-TC-MIB
- Registered at
- 1.3.6.1.4.1.5591.1.11.5.1
- Last updated
- 2008-07-23 13:00
- Organization
- SCTE HMS Working Group
- Revisions
- 2008-07-23 13:00, 2008-07-12 13:00, 2008-01-16 13:00, 2007-12-17 00:00
- Namespace
- standard
- Source file
SCTE-HMS-HEADENDIDENT-TC-MIB- Digest
sha256:3c14bde2b9be3256ec36ecd264082d4fe7e7a3e7e19ddc4a9206500ed141a411
Description
The MIB module is for representing general information about HeadEnd Digital equipment present(or indoor) and is supported by an SNMP agent.
Contact
SCTE HMS Subcommittee, Chairman mail to: standards@scte.org
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
2 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SCTE-HMS-HEADENDIDENT-TC-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| DeviceEnableDisableValues TEXTUAL-CONVENTION This data type represents whether the object is disabled(1) or enabled(2), or the object is not supported (3) by the current configuration or this device's hardware. | current | |||
| HeAlarmControl TEXTUAL-CONVENTION Alarm Control value for a specific device. This object is used to control sending traps related to this headend entity or enabling disabling of raising an alarm condition for a specific entity. | current | |||
| HeClockSource TEXTUAL-CONVENTION An enumerated value that provides the location where the value for the clock on the module is coming from. internal - this value is being derived internally from the local module timing source. external - an source that is external to the module, such as a controller card is providing a signal to calculate the real time clock. ntp - this module is running the ntp protocol and can sync up to a master ntp clock source. other - the real time clock source does not fit into the existing values. | current | |||
| HeDigitalAlarmSeverity TEXTUAL-CONVENTION The alarm severity that is determined by the device and sent over in the trap message. | current | |||
| HeDigitalAlarmType TEXTUAL-CONVENTION The alarm type that describes the Event that caused the alarm. | current | |||
| HeFaultStatus TEXTUAL-CONVENTION An enumerated value that provides a fault status of a particular hardware or software parameter that usually represent some sort of condition. A value normal(1) indicates the normal condition. A value fault(2) indicates the fault condition. | current | |||
| HeHundredthNanoMeter TEXTUAL-CONVENTION This data type represents wavelength values that are normally expressed in nano meters. Units are in hundredths of a NanoMeter; for example, 1550.56 nm will be represented as 155056. | current | |||
| HeHundredthWatts TEXTUAL-CONVENTION This data type represents power values that are normally expressed in watts. Units are in hundredths of a watt; for example, 420 watts will be represented as 42000. | current | |||
| HeMilliAmp TEXTUAL-CONVENTION This data type represents current levels that are normally expressed in amperes. Units are in milliamperes; for example, 2.1 Amperes would be expressed as 2100. | current | |||
| HeOnOffControl TEXTUAL-CONVENTION An enumerated value that provides a control of a particular hardware or software parameter that usually represent some sort of switch. A SET request with a value off(1) will cause the switch to be shut off. A SET request with a value on(2) will cause the switch to be turned on. A value meaningless(3) will be implemented by the variables that represent a switch with write-only access. A GET request for the value of the write-only variable shall return a value meaningless(3). A SET request with a value meaningless(3) for the variable with write access shall have no effect and no exception is generated. A value may be used by the variables with both read-write and write-only access. The variables with read-only access shall be defined with the textual convention HeOnOffStatus. | current | |||
| HeOnOffStatus TEXTUAL-CONVENTION An enumerated value that provides a status of a particular hardware or software parameter that usually represent some sort of switch. A value off(1) indicates the switch is off. A value on(2) indicates the switch is on. | current | |||
| HePIDValue TEXTUAL-CONVENTION This data type represents a packet identifier (PID) value which ranges from 0 to (2^13 - 1). The value of 65535 indicates that either the PID is invalid or does not exist. | current | |||
| HeResetValue TEXTUAL-CONVENTION Configured reset value for a specific device. reset - the value of reset is SET at the device and the device will reset. running - the normal value of the device is running when an SNMP GET of the reset value is sent. resetting - The value resetting shall be returned if an SNMP GET of the device is performed after a reset SET command is sent and before the device can actually perform the reset. A second reset SET command should not interrupt the reset sequence. If a second SET is sent, it will be ignored. | current | |||
| HeTenthCentigrade TEXTUAL-CONVENTION This data type represents temperature values that are normally expressed in Centigrade. Units are in tenths of a Centigrade; for example, -5.1 Centigrade will be represented as -51. | current | |||
| HeTenthVolt TEXTUAL-CONVENTION This data type represents voltage levels that are normally expressed in volts. Units are in tenths of a volt; for example, -48.1 volts will be represented as -481. | current | |||
| HeTenthdB TEXTUAL-CONVENTION This data type represents power levels that are normally expressed in dB. Units are in tenths of a dB; for example, -5.1 dB will be represented as -51. | current | |||
| HeTenthdBm TEXTUAL-CONVENTION This data type represents power levels that are normally expressed in dBm. Units are in tenths of a dBm; for example, -5.1 dBm will be represented as -51. | current | |||
| HeTenthdBmV TEXTUAL-CONVENTION This data type represents power levels that are normally expressed in dBmV. Units are in tenths of a dBmV; for example, -5.1 dBmV will be represented as -51. | current | |||
| HeTrapRegenerate TEXTUAL-CONVENTION This value tells the SNMP Agent to send the Trap Regenerate Trap for all values of Current alarms for this entity. The device can provide for a means to send ALL current alarms, not just one specific entity. | current | |||
| MpegErrorStatus TEXTUAL-CONVENTION This data type represents whether the object is good(1) or has errors(2), or the object is not supported (3) by the current configuration or this device's hardware. | current | |||
| ProgDataType TEXTUAL-CONVENTION This value defines the types of data that can be contained in Programs and program streams. | current | |||
| QAMChannelInterleaveMode TEXTUAL-CONVENTION This value defines the types of QAM Interleave Mode which follows the value of docsIfDownChannelInterleave. This value is supported by HMS QAM devices. | current | |||
| QAMChannelModulationFormat TEXTUAL-CONVENTION This value defines the types of QAM Channel Modulation that is supported by QAM devices. | current | |||
| VideoInputFrameRateType TEXTUAL-CONVENTION This value defines the types of MPEG Video Input Frame Rate that is supported by QAM devices. | current |