HP-SN-TRAP-MIB
- Registered at
- 1.3.6.1.4.1.11.0.11.3.6.1.4.1.11.0.21.3.6.1.4.1.11.0.191.3.6.1.4.1.11.0.201.3.6.1.4.1.11.0.211.3.6.1.4.1.11.0.221.3.6.1.4.1.11.0.231.3.6.1.4.1.11.0.241.3.6.1.4.1.11.0.251.3.6.1.4.1.11.0.261.3.6.1.4.1.11.0.271.3.6.1.4.1.11.0.281.3.6.1.4.1.11.0.291.3.6.1.4.1.11.0.301.3.6.1.4.1.11.0.311.3.6.1.4.1.11.0.321.3.6.1.4.1.11.0.331.3.6.1.4.1.11.0.341.3.6.1.4.1.11.0.351.3.6.1.4.1.11.0.361.3.6.1.4.1.11.0.371.3.6.1.4.1.11.0.381.3.6.1.4.1.11.0.391.3.6.1.4.1.11.0.401.3.6.1.4.1.11.0.411.3.6.1.4.1.11.0.421.3.6.1.4.1.11.0.431.3.6.1.4.1.11.0.441.3.6.1.4.1.11.0.451.3.6.1.4.1.11.0.46
- Namespace
- hp
- Source file
HP-SN-TRAP-MIB- Digest
sha256:5e99363baf97e17d135636648510d58a4a51d11f64763c75458fb7eff219a5bc
Imports
| From | Symbols |
|---|---|
| HP-SN-AGENT-MIB | snAgGblTrapMessage, snAgentBrdIndex, snChasFanDescription, snChasFanIndex, snChasPwrSupplyDescription, snChasPwrSupplyIndex, snChasPwrSupplyStatus |
| HP-SN-OSPF-GROUP-MIB | snOspfConfigErrorType, snOspfExtLsdbLimit, snOspfIfStatusIpAddress, snOspfIfStatusState, snOspfLsdbAreaId, snOspfLsdbLsId, snOspfLsdbRouterId, snOspfLsdbType, snOspfNbrIpAddr, snOspfNbrRtrId, snOspfNbrState, snOspfPacketSrc, snOspfPacketType, snOspfRouterId, snOspfVirtIfStatusAreaID, snOspfVirtIfStatusNeighbor, snOspfVirtIfStatusState, snOspfVirtNbrArea, snOspfVirtNbrRtrId, snOspfVirtNbrState |
| HP-SN-ROOT-MIB | hp |
| HP-SN-SW-L4-SWITCH-GROUP-MIB | snL4MaxSessionLimit, snL4TcpSynLimit, snL4TrapRealServerCurConnections, snL4TrapRealServerIP, snL4TrapRealServerName, snL4TrapRealServerPort |
| HP-SN-SWITCH-GROUP-MIB | snSwViolatorMacAddress, snSwViolatorPortNumber |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HP-SN-AGENT-MIB HP-SN-OSPF-GROUP-MIB HP-SN-ROOT-MIB HP-SN-SW-L4-SWITCH-GROUP-MIB HP-SN-SWITCH-GROUP-MIB HP-SN-TRAP-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Notifications
| Name | OID | Status |
|---|---|---|
| snTrapChasPwrSupply NOTIFICATION-TYPE The SNMP trap that is generated when a power supply fails to operate normally. | 1.3.6.1.4.1.11.0.1 | |
| snTrapLockedAddressViolation NOTIFICATION-TYPE The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port. | 1.3.6.1.4.1.11.0.2 | |
| snTrapOspfIfStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of a non-virtual OSPF interface. This trap should be generated when the interface state regresses (e.g., goes from Dr to Down) or progresses to a terminal state (i.e., Point-to-Point, DR Other, Dr, or Backup). | 1.3.6.1.4.1.11.0.3 | |
| snTrapOspfVirtIfStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual interface. This trap should be generated when the inter- face state regresses (e.g., goes from Point- to-Point to Down) or progresses to a terminal state (i.e., Point-to-Point). | 1.3.6.1.4.1.11.0.4 | |
| snOspfNbrStateChange NOTIFICATION-TYPE An ospfNbrStateChange trap signifies that there has been a change in the state of a non- virtual OSPF neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., 2-Way or Full). When an neighbor transitions from or to Full on non-broadcast multi-access and broadcast networks, the trap should be gen- erated by the designated router. A designated router transitioning to Down will be noted by ospfIfStateChange. | 1.3.6.1.4.1.11.0.5 | |
| snOspfVirtNbrStateChange NOTIFICATION-TYPE An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., Full). | 1.3.6.1.4.1.11.0.6 | |
| snOspfIfConfigError NOTIFICATION-TYPE An ospfIfConfigError trap signifies that a packet has been received on a non-virtual in- terface from a router whose configuration parameters conflict with this router's confi- guration parameters. Note that the event op- tionMismatch should cause a trap only if it prevents an adjacency from forming. | 1.3.6.1.4.1.11.0.7 | |
| snOspfVirtIfConfigError NOTIFICATION-TYPE An ospfConfigError trap signifies that a pack- et has been received on a virtual interface from a router whose configuration parameters conflict with this router's configuration parameters. Note that the event optionMismatch should cause a trap only if it prevents an ad- jacency from forming. | 1.3.6.1.4.1.11.0.8 | |
| snOspfIfAuthFailure NOTIFICATION-TYPE An ospfIfAuthFailure trap signifies that a packet has been received on a non-virtual in- terface from a router whose authentication key or authentication type conflicts with this router's authentication key or authentication type. | 1.3.6.1.4.1.11.0.9 | |
| snOspfVirtIfAuthFailure NOTIFICATION-TYPE An ospfVirtIfAuthFailure trap signifies that a packet has been received on a virtual interface from a router whose authentication key or au- thentication type conflicts with this router's authentication key or authentication type. | 1.3.6.1.4.1.11.0.10 | |
| snOspfIfRxBadPacket NOTIFICATION-TYPE An ospfIfRxBadPacket trap signifies that an OSPF packet has been received on a non-virtual interface that cannot be parsed. | 1.3.6.1.4.1.11.0.11 | |
| snOspfVirtIfRxBadPacket NOTIFICATION-TYPE An ospfRxBadPacket trap signifies that an OSPF packet has been received on a virtual interface that cannot be parsed. | 1.3.6.1.4.1.11.0.12 | |
| snOspfTxRetransmit NOTIFICATION-TYPE An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a non- virtual interface. All packets that may be re- transmitted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. | 1.3.6.1.4.1.11.0.13 | |
| ospfVirtIfTxRetransmit NOTIFICATION-TYPE An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a virtual interface. All packets that may be retransmit- ted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. | 1.3.6.1.4.1.11.0.14 | |
| snOspfOriginateLsa NOTIFICATION-TYPE An ospfOriginateLsa trap signifies that a new LSA has been originated by this router. This trap should not be invoked for simple refreshes of LSAs (which happesn every 30 minutes), but instead will only be invoked when an LSA is (re)originated due to a topology change. Addi- tionally, this trap does not include LSAs that are being flushed because they have reached MaxAge. | 1.3.6.1.4.1.11.0.15 | |
| snOspfMaxAgeLsa NOTIFICATION-TYPE An ospfMaxAgeLsa trap signifies that one of the LSA in the router's link-state database has aged to MaxAge. | 1.3.6.1.4.1.11.0.16 | |
| snOspfLsdbOverflow NOTIFICATION-TYPE An ospfLsdbOverflow trap signifies that the number of LSAs in the router's link-state data- base has exceeded ospfExtLsdbLimit. | 1.3.6.1.4.1.11.0.17 | |
| snOspfLsdbApproachingOverflow NOTIFICATION-TYPE An ospfLsdbApproachingOverflow trap signifies that the number of LSAs in the router's link- state database has exceeded ninety percent of ospfExtLsdbLimit. | 1.3.6.1.4.1.11.0.18 | |
| snTrapL4MaxSessionLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the maximum number of connections reached. | 1.3.6.1.4.1.11.0.19 | |
| snTrapL4TcpSynLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the number of TCP SYN limits reached. | 1.3.6.1.4.1.11.0.20 | |
| snTrapL4RealServerUp NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server is up. | 1.3.6.1.4.1.11.0.21 | |
| snTrapL4RealServerDown NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server is down. | 1.3.6.1.4.1.11.0.22 | |
| snTrapL4RealServerPortUp NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server TCP port is up. | 1.3.6.1.4.1.11.0.23 | |
| snTrapL4RealServerPortDown NOTIFICATION-TYPE The SNMP trap that is generated when the load balancing real server TCP port is down. | 1.3.6.1.4.1.11.0.24 | |
| snTrapL4RealServerMaxConnectionLimitReached NOTIFICATION-TYPE The SNMP trap that is generated when the real server reaches maximum number of connections. | 1.3.6.1.4.1.11.0.25 | |
| snTrapL4BecomeStandby NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch changes state from active to standby. | 1.3.6.1.4.1.11.0.26 | |
| snTrapL4BecomeActive NOTIFICATION-TYPE The SNMP trap that is generated when the server load balancing switch changes state from standby to active. | 1.3.6.1.4.1.11.0.27 | |
| snTrapModuleInserted NOTIFICATION-TYPE The SNMP trap that is generated when a module was inserted to the chassis during system running. | 1.3.6.1.4.1.11.0.28 | |
| snTrapModuleRemoved NOTIFICATION-TYPE The SNMP trap that is generated when a module was removed from the chassis during system running. | 1.3.6.1.4.1.11.0.29 | |
| snTrapChasPwrSupplyFailed NOTIFICATION-TYPE The SNMP trap that is generated when a power supply fails to operate normally. | 1.3.6.1.4.1.11.0.30 | |
| snTrapChasFanFailed NOTIFICATION-TYPE The SNMP trap that is generated when a fan fails to operate normally. | 1.3.6.1.4.1.11.0.31 | |
| snTrapLockedAddressViolation2 NOTIFICATION-TYPE The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port. | 1.3.6.1.4.1.11.0.32 | |
| snTrapFsrpIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a FSRP routing device changed state from active to standby or vice-versa. | 1.3.6.1.4.1.11.0.33 | |
| snTrapVrrpIfStateChange NOTIFICATION-TYPE The SNMP trap that is generated when a VRRP routing device changed state from master to backup or vice-versa. | 1.3.6.1.4.1.11.0.34 | |
| snTrapMgmtModuleRedunStateChange NOTIFICATION-TYPE The SNMP trap that is generated when the management module changes redundancy state. | 1.3.6.1.4.1.11.0.35 | |
| snTrapTemperatureWarning NOTIFICATION-TYPE The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold. | 1.3.6.1.4.1.11.0.36 | |
| snTrapAccessListDeny NOTIFICATION-TYPE The SNMP trap that is generated when a packet was denied by an access list. | 1.3.6.1.4.1.11.0.37 | |
| snTrapMacFilterDeny NOTIFICATION-TYPE The SNMP trap that is generated when a packet was denied by a MAC address filter. | 1.3.6.1.4.1.11.0.38 | |
| snTrapL4GslbRemoteUp NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the remote SI is established. | 1.3.6.1.4.1.11.0.39 | |
| snTrapL4GslbRemoteDown NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the remote SI is down. | 1.3.6.1.4.1.11.0.40 | |
| snTrapL4GslbRemoteControllerUp NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the GSLB SI is established. | 1.3.6.1.4.1.11.0.41 | |
| snTrapL4GslbRemoteControllerDown NOTIFICATION-TYPE The SNMP trap that is generated when the connection to the GSLB SI is down. | 1.3.6.1.4.1.11.0.42 | |
| snTrapL4GslbHealthCheckIpUp NOTIFICATION-TYPE The SNMP trap that is generated when GSLB health check for an address transitions from down to active state. | 1.3.6.1.4.1.11.0.43 | |
| snTrapL4GslbHealthCheckIpDown NOTIFICATION-TYPE The SNMP trap that is generated when GSLB health check for an address transitions from active to down state. | 1.3.6.1.4.1.11.0.44 | |
| snTrapL4GslbHealthCheckIpPortUp NOTIFICATION-TYPE The SNMP trap that is generated when a given port for a health check address is up. | 1.3.6.1.4.1.11.0.45 | |
| snTrapL4GslbHealthCheckIpPortDown NOTIFICATION-TYPE The SNMP trap that is generated when a given port for a health check address is down. | 1.3.6.1.4.1.11.0.46 |