MIBs Depot

H3C-STORAGE-MIB

Registered at
1.3.6.1.4.1.2011.10.10.1
Last updated
2007-09-04 14:52
Organization
H3C Technologies Co., Ltd.
Namespace
huawei
Source file
H3C-STORAGE-MIB
Digest
sha256:671df6775a02d2713147fafe2d8de84b41d6351742ab3f465fa53d8ad365ce1d

Description

This MIB describes the general information of storage device, such as the property, configuration and management.

Contact

Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.h3c.com Zip:100085

Imports

FromSymbols
ENTITY-MIBPhysicalIndex, entPhysicalDescr, entPhysicalIndex, entPhysicalName
H3C-DISK-MIBh3cDiskPowerOffReason
H3C-ENTITY-EXT-MIBh3cEntityExtCriticalLowerTemperatureThreshold, h3cEntityExtOperStatus, h3cEntityExtPhysicalIndex, h3cEntityExtShutdownLowerTemperatureThreshold, h3cEntityExtTemperature
H3C-RAID-MIBh3cRaidHideState, h3cRaidName, h3cRaidRunState, h3cRaidUuid
H3C-STORAGE-REF-MIBH3cSoftwareInfoString, H3cStorageActionType, H3cStorageCapableState, H3cStorageEnableState, H3cStorageLedStateType, H3cWwpnListType, h3cStorageRef
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
H3C-DISK-MIB
H3C-ENTITY-EXT-MIB
H3C-RAID-MIB
H3C-STORAGE-MIB
H3C-STORAGE-REF-MIB
HUAWEI-3COM-OID-MIB
IANA-ENTITY-MIB
INET-ADDRESS-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Objects

NameOIDSyntaxAccessStatus
h3cStorageMibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1
h3cStorageServerInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.1
h3cStorageServerCapability
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.1.1
h3cRaidCapability
OBJECT-TYPE
This object identifies if the agent support raid management.
1.3.6.1.4.1.2011.10.10.1.1.1.1.1H3cStorageCapableStateread-onlycurrent
h3cFcCapability
OBJECT-TYPE
This object identifies if the agent support FC(fiber channel) management.
1.3.6.1.4.1.2011.10.10.1.1.1.1.2H3cStorageCapableStateread-onlycurrent
h3cNasCapability
OBJECT-TYPE
This object identifies if the agent support NAS(Network Attached Storage).
1.3.6.1.4.1.2011.10.10.1.1.1.1.3H3cStorageCapableStateread-onlycurrent
h3cAdaptiveRepCapability
OBJECT-TYPE
This object identifies if the agent support adaptive replication. With adaptive replication option, data from the primary resource is continuously replicated to a replication resource unless the system determines it is not practical or possible, such as when there is insufficient bandwidth. For continuous replication to occur, a continuous replication resource is used to stage the data being replicated from the primary resource. Similar to a cache, as soon as data comes into the continuous replication resource, it is written to the replication resource.
1.3.6.1.4.1.2011.10.10.1.1.1.1.4H3cStorageCapableStateread-onlycurrent
h3cRemoteRepCapability
OBJECT-TYPE
This object identifies if the agent support remote replication.
1.3.6.1.4.1.2011.10.10.1.1.1.1.5H3cStorageCapableStateread-onlycurrent
h3cSafeCacheCapability
OBJECT-TYPE
This object identifies if the agent support safe cache.
1.3.6.1.4.1.2011.10.10.1.1.1.1.6H3cStorageCapableStateread-onlycurrent
h3cSyncMirrorCapability
OBJECT-TYPE
This object identifies if the agent support synchronized mirror.
1.3.6.1.4.1.2011.10.10.1.1.1.1.7H3cStorageCapableStateread-onlycurrent
h3cAsyncMirrorCapability
OBJECT-TYPE
This object identifies if the agent support asynchronous mirror.
1.3.6.1.4.1.2011.10.10.1.1.1.1.8H3cStorageCapableStateread-onlycurrent
h3cTimeMarkCapability
OBJECT-TYPE
This object identifies if the agent support time mark.
1.3.6.1.4.1.2011.10.10.1.1.1.1.9H3cStorageCapableStateread-onlycurrent
h3cSseCapability
OBJECT-TYPE
This object identifies if the agent support SSE(Storage Service Enable).
1.3.6.1.4.1.2011.10.10.1.1.1.1.10H3cStorageCapableStateread-onlycurrent
h3cStorageTargetConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.1.2
h3ciSCSITargetEnable
OBJECT-TYPE
This object identifies if the agent support iSCSI target.
1.3.6.1.4.1.2011.10.10.1.1.1.2.1H3cStorageEnableStateread-writecurrent
h3cFcTargetEnable
OBJECT-TYPE
This object identifies if the agent support FC target.
1.3.6.1.4.1.2011.10.10.1.1.1.2.2H3cStorageEnableStateread-writecurrent
h3cStorageServerPhysInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.1.3
h3cServerLocationLedState
OBJECT-TYPE
This object identifies the state of storage device's location led.
1.3.6.1.4.1.2011.10.10.1.1.1.3.1H3cStorageLedStateTyperead-writecurrent
h3cServerResetButtonState
OBJECT-TYPE
This object identifies if the reset button is enable.
1.3.6.1.4.1.2011.10.10.1.1.1.3.2H3cStorageEnableStateread-writecurrent
h3cServerPowerButtonState
OBJECT-TYPE
This object identifies if the power button is enable.
1.3.6.1.4.1.2011.10.10.1.1.1.3.3H3cStorageEnableStateread-writecurrent
h3cServerPowerState
OBJECT-TYPE
This object identifies the state of power supply in the server, and is valid when UPS has been configured successful. The value 'online' means power supply is well-balanced. The value 'onlinebypass' means supply power without ups. The value 'onbattery' means supply power with battery. The value 'unknown' means the power supply state is unknown.
1.3.6.1.4.1.2011.10.10.1.1.1.3.4INTEGER {online(1), onlinebypass(2), onbattery(3), unknown(4)}read-onlycurrent
h3cStoragePhysicalInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.2
h3cDeuTable
OBJECT-TYPE
This table contains some information of a particular DEU(Disk Enclosure Unit).
1.3.6.1.4.1.2011.10.10.1.1.2.1not-accessiblecurrent
h3cDeuEntry
OBJECT-TYPE
An entry containing management information applicable to a particular DEU.
1.3.6.1.4.1.2011.10.10.1.1.2.1.1not-accessiblecurrent
h3cDeuIndex
OBJECT-TYPE
This object identifies the index of h3cDeuTable. The DEU identified by a particular value of this index is the same object as identified by the same value of entPhysicalIndex.
1.3.6.1.4.1.2011.10.10.1.1.2.1.1.1Integer32not-accessiblecurrent
h3cDeuIDLed
OBJECT-TYPE
This object identifies the state of storage DEU's led.
1.3.6.1.4.1.2011.10.10.1.1.2.1.1.2H3cStorageLedStateTyperead-writecurrent
h3cDeuDiskScan
OBJECT-TYPE
The operation of scanning the table. When the value of this object is set to 'action', the operation of disk scanning is touched off.
1.3.6.1.4.1.2011.10.10.1.1.2.1.1.3H3cStorageActionTyperead-writecurrent
h3cStorageInterfaceTable
OBJECT-TYPE
This table describes the interface information of the network.
1.3.6.1.4.1.2011.10.10.1.1.2.2not-accessiblecurrent
h3cStorageInterfaceEntry
OBJECT-TYPE
An entry containing management information applicable to a particular interface.
1.3.6.1.4.1.2011.10.10.1.1.2.2.1not-accessiblecurrent
h3cStorageInterfaceIndex
OBJECT-TYPE
This object identifies the index of H3cStorageInterfaceEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex.
1.3.6.1.4.1.2011.10.10.1.1.2.2.1.1Integer32not-accessiblecurrent
h3cStorageInterfaceGateway
OBJECT-TYPE
This object identifies the gateway address of interface.
1.3.6.1.4.1.2011.10.10.1.1.2.2.1.2InetAddressread-writecurrent
h3cStorageInterfaceGatewayType
OBJECT-TYPE
This object identifies the gateway address type of interface.
1.3.6.1.4.1.2011.10.10.1.1.2.2.1.3InetAddressTyperead-writecurrent
h3cStorageInterfaceMTU
OBJECT-TYPE
This object identifies the MTU of interface.
1.3.6.1.4.1.2011.10.10.1.1.2.2.1.4INTEGER {mtu1(1500), mtu2(9000)}read-writecurrent
h3cBondingTable
OBJECT-TYPE
This table describes the information of the Bonding interface.
1.3.6.1.4.1.2011.10.10.1.1.2.3not-accessiblecurrent
h3cBondingEntry
OBJECT-TYPE
An entry containing management information applicable to a particular Bonding interface.
1.3.6.1.4.1.2011.10.10.1.1.2.3.1not-accessiblecurrent
h3cBondingIndex
OBJECT-TYPE
This object identifies the index of h3cBondingEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex.
1.3.6.1.4.1.2011.10.10.1.1.2.3.1.1Integer32not-accessiblecurrent
h3cBondingPortList
OBJECT-TYPE
An entry contains management information applicable to a particular bonding interface. Every two bytes describe the ifIndex of an interface, and an interface belongs to one bonding group only. An interface should be deleted from the portlist of the bonding group it belongs to before it is added to another bonding group.
1.3.6.1.4.1.2011.10.10.1.1.2.3.1.2OCTET STRINGread-writecurrent
h3cScsiAdapterTable
OBJECT-TYPE
This table containing some information of the SCSI(Small Computer System interface) adapter.
1.3.6.1.4.1.2011.10.10.1.1.2.4not-accessiblecurrent
h3cScsiAdapterEntry
OBJECT-TYPE
An entry containing management information applicable to a particular SCSI adapter.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1not-accessiblecurrent
h3cAdapterNumber
OBJECT-TYPE
This object identifies the index of the adapter .
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.1Integer32not-accessiblecurrent
h3cAdapterDesc
OBJECT-TYPE
This object describes some information of the adapter.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.2OCTET STRINGread-onlycurrent
h3cAdapterType
OBJECT-TYPE
This object identifies the type of adapter. If the value of this object is not equal to 'fc', the associated object(such as h3cFcAdapterMode, h3cFcAdapterIWWPNs,h3cFcAdapterTWWPNs,h3cFcAdapterPortState,h3cFcAdapterModeSwitch) will be invalid.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.3INTEGER {scsi(1), fc(2)}read-onlycurrent
h3cFcAdapterMode
OBJECT-TYPE
This object identifies the mode type of adapter.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.4INTEGER {initiator(1), target(2), dual(3)}read-onlycurrent
h3cFcAdapterInitiatorWwpnName
OBJECT-TYPE
This object describes the FC's adapter WWPN(World Wide Port Name) numbers.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.5H3cWwpnListTyperead-onlycurrent
h3cFcAdapterTargetWwpnName
OBJECT-TYPE
This object describes the FC's target WWPN numbers.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.6H3cWwpnListTyperead-onlycurrent
h3cFcAdapterPortState
OBJECT-TYPE
This object identifies the state of adapter's interface.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.7INTEGER {linkup(1), linkdown(2)}read-onlycurrent
h3cFcAdapterModeSwitch
OBJECT-TYPE
This object identifies if the adapter work on a target mode.
1.3.6.1.4.1.2011.10.10.1.1.2.4.1.8H3cStorageEnableStateread-writecurrent
h3cExtVoltageTable
OBJECT-TYPE
This table contains some entity extend information of the voltage.
1.3.6.1.4.1.2011.10.10.1.1.2.5not-accessiblecurrent
h3cExtVoltageEntry
OBJECT-TYPE
An entry containing management information applicable to the voltage.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1not-accessiblecurrent
h3cExtVoltagePhysicalIndex
OBJECT-TYPE
This object identifies the entity index of voltage.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.1PhysicalIndexaccessible-for-notifycurrent
h3cExtVoltagePhysicalName
OBJECT-TYPE
This object identifies the entity name of voltage.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.2SnmpAdminStringread-onlycurrent
h3cExtVoltage
OBJECT-TYPE
The voltage for the entity.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.3Integer32read-onlycurrent
h3cExtVoltageLowThreshold
OBJECT-TYPE
The low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.4Integer32read-writecurrent
h3cExtVoltageHighThreshold
OBJECT-TYPE
The high-threshold for the voltage. When voltage is higher than high-threshold, a notification will be sent.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.5Integer32read-writecurrent
h3cExtCriticalVoltageLowThreshold
OBJECT-TYPE
The critical low threshold for voltage. If the voltage is lower too much than the entity needs, the entity will halt.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6Integer32read-writecurrent
h3cExtCriticalVoltageHighThreshold
OBJECT-TYPE
The critical high threshold for voltage. If the voltage is higher too much than the entity needs, the entity will halt.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.7Integer32read-writecurrent
h3cExtShutdownVoltageLowThreshold
OBJECT-TYPE
The voltage is lower than the critical low threshold. If the voltage is lower too much than the entity needs, the entity halts now.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.8Integer32read-writecurrent
h3cExtShutdownVoltageHighThreshold
OBJECT-TYPE
The voltage is higher than the critical high threshold. If the voltage is higher too much than the entity needs, the entity halts now.
1.3.6.1.4.1.2011.10.10.1.1.2.5.1.9Integer32read-writecurrent
h3cStorageTraps
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.3
h3cStorageTrapsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.3.0
h3cStorageTrapsObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.10.1.1.3.1
h3cSoftwareInfoString
OBJECT-TYPE
This object identifies if the software's information.
1.3.6.1.4.1.2011.10.10.1.1.3.1.1H3cSoftwareInfoStringread-onlycurrent

Notifications

NameOIDStatus
h3cStorCriticalLowerTemperatureThresholdNotification
NOTIFICATION-TYPE
The h3cStorCriticalLowerTemperatureThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity will halt.
1.3.6.1.4.1.2011.10.10.1.1.3.0.1current
h3cStorTemperatureTooLow
NOTIFICATION-TYPE
The h3cStorTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity halts now.
1.3.6.1.4.1.2011.10.10.1.1.3.0.2current
h3cExtVoltageLowThresholdNotification
NOTIFICATION-TYPE
The h3cExtVoltageLowThresholdNotification indicates the Voltage is lower than the low-threshold.
1.3.6.1.4.1.2011.10.10.1.1.3.0.3current
h3cExtVoltageHighThresholdNotification
NOTIFICATION-TYPE
The h3cExtVoltageHighThresholdNotification indicates the Voltage is lower than the high-threshold.
1.3.6.1.4.1.2011.10.10.1.1.3.0.4current
h3cExtCriticalVoltageLowThresholdNotification
NOTIFICATION-TYPE
The h3cExtCriticalVoltageLowThresholdNotification indicates the Voltage is lower than the critical low threshold.
1.3.6.1.4.1.2011.10.10.1.1.3.0.5current
h3cExtCriticalVoltageHighThresholdNotification
NOTIFICATION-TYPE
The h3cExtCriticalVoltageHighThresholdNotification indicates the Voltage is higher than the critical high threshold.
1.3.6.1.4.1.2011.10.10.1.1.3.0.6current
h3cExtVoltageTooLow
NOTIFICATION-TYPE
The h3cExtVoltageTooLowNotification indicates the Voltage is lower than the critical low threshold, and the entity halt now!
1.3.6.1.4.1.2011.10.10.1.1.3.0.7current
h3cExtVoltageTooHigh
NOTIFICATION-TYPE
The h3cExtVoltageTooHighNotification indicates the Voltage is higher than the critical high threshold, and the entity halt now!
1.3.6.1.4.1.2011.10.10.1.1.3.0.8current
h3cExtBatteryStateNotification
NOTIFICATION-TYPE
The h3cExtBatteryStateNotification indicates the raid battery entity's state changes.
1.3.6.1.4.1.2011.10.10.1.1.3.0.9current
h3cDiskIOErrorNotification
NOTIFICATION-TYPE
The h3cDiskIOErrorNotification indicates that a disk occurred I/O error.
1.3.6.1.4.1.2011.10.10.1.1.3.0.10current
h3cRaidCreateNotification
NOTIFICATION-TYPE
The h3cRaidCreateNotification indicates that a array is created.
1.3.6.1.4.1.2011.10.10.1.1.3.0.11current
h3cRaidDeleteNotification
NOTIFICATION-TYPE
The h3cRaidDeleteStateNotification indicates that a array is deleted.
1.3.6.1.4.1.2011.10.10.1.1.3.0.12current
h3cRaidHideStateNotification
NOTIFICATION-TYPE
The h3cRaidFailedNotification indicates that a array hide or unhide.
1.3.6.1.4.1.2011.10.10.1.1.3.0.13current
h3cRaidRunStateNotification
NOTIFICATION-TYPE
The h3cRaidDegradeNotification indicates that a array state change.
1.3.6.1.4.1.2011.10.10.1.1.3.0.14current
h3cRaidImportNotification
NOTIFICATION-TYPE
The h3cRaidFailedNotification indicates that a thrid array is imported.
1.3.6.1.4.1.2011.10.10.1.1.3.0.15current
h3cRaidRebuildStartNotification
NOTIFICATION-TYPE
The h3cRaidRebuildStartNotification indicates that a array start to rebuild.
1.3.6.1.4.1.2011.10.10.1.1.3.0.16current
h3cRaidRebuildFinishNotification
NOTIFICATION-TYPE
The h3cRaidRebuildStartNotification indicates that a array fininsh rebuild.
1.3.6.1.4.1.2011.10.10.1.1.3.0.17current
h3cRaidRebuildPauseNotification
NOTIFICATION-TYPE
The h3cRaidRebuildPauseNotification indicates that pause a array rebuilding.
1.3.6.1.4.1.2011.10.10.1.1.3.0.18current
h3cRaidRebuildInterruptNotification
NOTIFICATION-TYPE
The h3cRaidRebuildInterruptNotification indicates that interrupt a array rebuilding.
1.3.6.1.4.1.2011.10.10.1.1.3.0.19current
h3cSoftwareModuleFailNotification
NOTIFICATION-TYPE
The h3cSoftwareModuleFailNotification indicates that software module(s) fail.
1.3.6.1.4.1.2011.10.10.1.1.3.0.20current
h3cRaidBatteryExpiredNotification
NOTIFICATION-TYPE
The h3cRaidBatteryExpiredNotification indicates RAID Battery lifetime had expired.
1.3.6.1.4.1.2011.10.10.1.1.3.0.21current
h3cRaidBatteryWillExpireNotification
NOTIFICATION-TYPE
The h3cRaidBatteryWillExpireNotification indicates RAID Battery lifetime will expire.
1.3.6.1.4.1.2011.10.10.1.1.3.0.22current
h3cLvOnlineFailNotification
NOTIFICATION-TYPE
The h3cLvOnlineFailNotification indicates lv(s) on vd fail to online.
1.3.6.1.4.1.2011.10.10.1.1.3.0.23current
h3cLvOfflineFailNotification
NOTIFICATION-TYPE
The h3cLvOfflineFailNotification indicates lv(s) on vd fail to offline.
1.3.6.1.4.1.2011.10.10.1.1.3.0.24current
h3cRaidRunNotification
NOTIFICATION-TYPE
The h3cRaidRunNotification indicates that a array is running.
1.3.6.1.4.1.2011.10.10.1.1.3.0.25current
h3cExtVoltageNormal
NOTIFICATION-TYPE
The h3cStorVoltageRecoveryNotification indicates the Voltage has recovered in reference.
1.3.6.1.4.1.2011.10.10.1.1.3.0.26current
h3cDiskPowerOnNotification
NOTIFICATION-TYPE
The h3cDiskPowerOnNotification indicates that a disk is power on.
1.3.6.1.4.1.2011.10.10.1.1.3.0.27current
h3cDiskPowerOffNotification
NOTIFICATION-TYPE
The h3cDiskPowerOffNotification indicates that a disk is power off.
1.3.6.1.4.1.2011.10.10.1.1.3.0.28current