MIBs Depot

EXTREME-TRAP-MIB

Registered at
1.3.6.1.4.1.1916.0.6
1.3.6.1.4.1.1916.0.7
1.3.6.1.4.1.1916.0.8
1.3.6.1.4.1.1916.0.9
1.3.6.1.4.1.1916.0.10
1.3.6.1.4.1.1916.0.11
1.3.6.1.4.1.1916.0.12
1.3.6.1.4.1.1916.0.13
1.3.6.1.4.1.1916.0.14
1.3.6.1.4.1.1916.0.15
1.3.6.1.4.1.1916.0.17
1.3.6.1.4.1.1916.0.18
1.3.6.1.4.1.1916.0.19
1.3.6.1.4.1.1916.0.20
1.3.6.1.4.1.1916.0.21
Namespace
extreme
Source file
EXTREME-BASE-MIB
Digest
sha256:920ec3f1c764d83d84c3c0ad6a4d3ca2aa2e105baf75bb47bf910c2a7454dbfc

Imports

FromSymbols
EXTREME-BASE-MIBextremeV1Traps, extremenetworks
EXTREME-EDP-MIBextremeEdpEntryAge, extremeEdpNeighborId, extremeEdpNeighborVlanIpAddress, extremeEdpNeighborVlanName, extremeEdpPortIfIndex
EXTREME-ESRP-MIBextremeEsrpActivePorts, extremeEsrpGroup, extremeEsrpInternalActivePorts, extremeEsrpNetAddress, extremeEsrpState, extremeEsrpTrackedActivePorts, extremeEsrpTrackedIpRoutes
EXTREME-SYSTEM-MIBextremeCurrentTemperature, extremeFanNumber, extremePowerSupplyNumber, extremeSlotModuleConfiguredType, extremeSlotModuleInsertedType, extremeSlotModuleState, extremeSlotNumber
EXTREME-VLAN-MIBextremeVlanIfDescr, extremeVlanIfIndex
IF-MIBifAlias, ifDescr, ifPhysAddress
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-MIBsysDescr, sysUpTime
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

EXTREME-BASE-MIB
EXTREME-EDP-MIB
EXTREME-ESRP-MIB
EXTREME-SYSTEM-MIB
EXTREME-TRAP-MIB
EXTREME-VLAN-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Notifications

NameOIDStatus
extremeOverheat
NOTIFICATION-TYPE
A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has suficiently cooled such that operation may begin again. A cold start trap will be issued when the unit has come back on line.
1.3.6.1.4.1.1916.0.6current
extremeFanfailed
NOTIFICATION-TYPE
A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation.
1.3.6.1.4.1.1916.0.7current
extremeFanOK
NOTIFICATION-TYPE
A fan has transitioned out of a failure state and is now operating correctly.
1.3.6.1.4.1.1916.0.8current
extremeInvalidLoginAttempt
NOTIFICATION-TYPE
A user attempted to login to console or by telnet but was refused access due to incorrect username or password
1.3.6.1.4.1.1916.0.9current
extremePowerSupplyFail
NOTIFICATION-TYPE
One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over.
1.3.6.1.4.1.1916.0.10current
extremePowerSupplyGood
NOTIFICATION-TYPE
One or more previously bad sources of power to this agent has come back to life without causing an agent restart.
1.3.6.1.4.1.1916.0.11current
extremeRpsAlarm
NOTIFICATION-TYPE
Attached Redundant Power Supply device is indicating an alarm condition.
1.3.6.1.4.1.1916.0.12current
extremeRpsNoAlarm
NOTIFICATION-TYPE
Attached Redundant Power Supply device is no longer indicating an alarm condition.
1.3.6.1.4.1.1916.0.13current
extremeSmartTrap
NOTIFICATION-TYPE
Signifies that the value of one of the object identifiers (or the value of an object below that in the MIB tree) defined in the extremeSmartTrapRulesTable has changed, and hence a new entry has been created in the extremeSmartTrapInstanceTable. Such a trap is sent at most once every thirty seconds if one or more entry was created in the last thirty seconds.
1.3.6.1.4.1.1916.0.14current
extremeModuleStateChanged
NOTIFICATION-TYPE
Signifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed.
1.3.6.1.4.1.1916.0.15current
extremeEsrpStateChange
NOTIFICATION-TYPE
Signifies Esrp state change
1.3.6.1.4.1.1916.0.17current
extremeSlbUnitAdded
NOTIFICATION-TYPE
The server load balancer has activated a group of virtual servers that it normally would not activate. This may be due to the failure of another server load balancer.
1.3.6.1.4.1.1916.0.18current
extremeSlbUnitRemoved
NOTIFICATION-TYPE
The server load balancer has deactivated a group of virtual servers that it normally has active. This indicates that something is wrong in the server load balancer; for example, its ping check may be failing.
1.3.6.1.4.1.1916.0.19current
extremeEdpNeighborAdded
NOTIFICATION-TYPE
This node discovers a new neighbor through Extreme Discovery Protocol.
1.3.6.1.4.1.1916.0.20current
extremeEdpNeighborRemoved
NOTIFICATION-TYPE
No EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device.
1.3.6.1.4.1.1916.0.21current