MIBs Depot

EXTREME-SYSTEM-MIB

Registered at
1.3.6.1.4.1.1916.1.1
Last updated
2011-04-01 00:00
Organization
Extreme Networks, Inc.
Namespace
extreme
Source file
EXTREME-SYSTEM-MIB
Digest
sha256:edff25beb5cfefd4b9e2ce14b7f3336483995a89dbc2468cc9d01cbbb0f9987c

Description

Extreme System objects: objects common to all platforms

Contact

www.extremenetworks.com

Imports

FromSymbols
EXTREME-BASE-MIBPortList, extremeAgent
IF-MIBifDescr
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-MIBsysDescr, sysUpTime
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

6 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

EXTREME-BASE-MIB
EXTREME-SYSTEM-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
PowerValue
TEXTUAL-CONVENTION
The input power value of the switch.
current
SlotType
TEXTUAL-CONVENTION
The type of the slot. It is used both for the configured as well as the inserted slot types.
current
UnitMultiplier
TEXTUAL-CONVENTION
The Unit Multiplier is an integer value that represents the IEEE 61850 Annex A units multiplier associated with the integer units used to measure the power or energy. For example, when used with pmPowerUnitMultiplier, -3 represents 10^-3 or milliwatts.
current

Objects

NameOIDSyntaxAccessStatus
extremeSystemCommon
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.1
extremeSaveConfiguration
OBJECT-TYPE
When this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value of the object. The save is performed asynchronously, and the snmp agent will continue to respond to both gets and sets while the save is taking place. A network management application may use the extremeSaveStatus object to determine when the asynchronous save operation has completed.
1.3.6.1.4.1.1916.1.1.1.3INTEGER {saveToPrimary(1), saveToSecondary(2), saveToCurrent(3), factoryDefault(4), saveToFile(5)}read-writecurrent
extremeSaveStatus
OBJECT-TYPE
This object will return the status of a save operation invoked by setting the extremeSaveConfiguration object. A network management application can read this object to determine that a save operation has completed.
1.3.6.1.4.1.1916.1.1.1.4INTEGER {saveInProgress(1), saveNotInProgress(2), saveNotReady(3)}read-onlycurrent
extremeCurrentConfigInUse
OBJECT-TYPE
Shows which NVRAM configuration store was used at last boot.
1.3.6.1.4.1.1916.1.1.1.5INTEGER {primary(1), secondary(2), other(3), factoryDefault(4)}read-onlycurrent
extremeConfigToUseOnReboot
OBJECT-TYPE
Controls which NVRAM configuration store will be used on next reboot.
1.3.6.1.4.1.1916.1.1.1.6INTEGER {primary(1), secondary(2), other(3)}read-writecurrent
extremeOverTemperatureAlarm
OBJECT-TYPE
Alarm status of overtemperature sensor in device enclosure.
1.3.6.1.4.1.1916.1.1.1.7TruthValueread-onlycurrent
extremeCurrentTemperature
OBJECT-TYPE
Current temperature in degrees celcius measured inside device enclosure.
1.3.6.1.4.1.1916.1.1.1.8INTEGER (0..100)read-onlycurrent
extremeFanStatusTable
OBJECT-TYPE
Table of operational status of all internal cooling fans.
1.3.6.1.4.1.1916.1.1.1.9not-accessiblecurrent
extremeFanStatusEntry
OBJECT-TYPE
Entry in table of all internal cooling fans.
1.3.6.1.4.1.1916.1.1.1.9.1not-accessiblecurrent
extremeFanNumber
OBJECT-TYPE
Identifier of cooling fan, numbered from the front and/or left side of device.
1.3.6.1.4.1.1916.1.1.1.9.1.1Integer32read-onlycurrent
extremeFanOperational
OBJECT-TYPE
Operational status of a cooling fan.
1.3.6.1.4.1.1916.1.1.1.9.1.2TruthValueread-onlycurrent
extremeFanEntPhysicalIndex
OBJECT-TYPE
The entity index for this fan entity in the entityPhysicalTable table of the entity MIB.
1.3.6.1.4.1.1916.1.1.1.9.1.3Integer32read-onlycurrent
extremeFanSpeed
OBJECT-TYPE
The speed (RPM) of a cooling fan in the fantray.
1.3.6.1.4.1.1916.1.1.1.9.1.4Integer32read-onlycurrent
extremePrimaryPowerOperational
OBJECT-TYPE
Operational status of internal power supply of a device.
1.3.6.1.4.1.1916.1.1.1.10TruthValueread-onlycurrent
extremeRedundantPowerStatus
OBJECT-TYPE
Operational status of an external redundant power supply to a device.
1.3.6.1.4.1.1916.1.1.1.11INTEGER {notPresent(1), presentOK(2), presentNotOK(3)}read-onlycurrent
extremeRedundantPowerAlarm
OBJECT-TYPE
Alarm state of an external redundant power supply to a device. Alarm state indicates either fan failure or overtemperature condition.
1.3.6.1.4.1.1916.1.1.1.12TruthValueread-onlycurrent
extremePrimarySoftwareRev
OBJECT-TYPE
The software revision of the primary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.
1.3.6.1.4.1.1916.1.1.1.13DisplayString (SIZE(0..80))read-onlycurrent
extremeSecondarySoftwareRev
OBJECT-TYPE
The software revision of the secondary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.
1.3.6.1.4.1.1916.1.1.1.14DisplayString (SIZE(0..80))read-onlycurrent
extremeImageToUseOnReboot
OBJECT-TYPE
Controls which image will be used on next reboot.
1.3.6.1.4.1.1916.1.1.1.15INTEGER {primary(1), secondary(2)}read-writecurrent
extremeSystemID
OBJECT-TYPE
This represents the System ID of the Summit Switch.
1.3.6.1.4.1.1916.1.1.1.16DisplayString (SIZE(0..126))read-onlycurrent
extremeSystemBoardID
OBJECT-TYPE
This represents the Board ID of the Summit Switch.
1.3.6.1.4.1.1916.1.1.1.17DisplayString (SIZE(0..126))read-onlycurrent
extremeSystemLeftBoardID
OBJECT-TYPE
This represents the Left Board ID of the Summit Switch.
1.3.6.1.4.1.1916.1.1.1.18DisplayString (SIZE(0..126))read-onlycurrent
extremeSystemRightBoardID
OBJECT-TYPE
This represents the Right Board ID of the Summit Switch.
1.3.6.1.4.1.1916.1.1.1.19DisplayString (SIZE(0..126))read-onlycurrent
extremeInputPowerVoltage
OBJECT-TYPE
The input power voltage at which the system is currently operating.
1.3.6.1.4.1.1916.1.1.1.20PowerValueread-onlycurrent
extremePowerStatus
OBJECT-TYPE
Operational status of the power supply to a device.
1.3.6.1.4.1.1916.1.1.1.21INTEGER {notPresent(1), presentOK(2), presentNotOK(3)}read-onlycurrent
extremePowerAlarm
OBJECT-TYPE
Alarm state of the power supply to a device. Alarm state indicates either fan failure or overtemperature condition.
1.3.6.1.4.1.1916.1.1.1.22TruthValueread-onlycurrent
extremeRmonEnable
OBJECT-TYPE
Setting this to true will cause the agent to start collecting RMON statistics.
1.3.6.1.4.1.1916.1.1.1.23TruthValueread-writecurrent
extremeBootROMVersion
OBJECT-TYPE
The software revision of the bootrom on the device. This string will have a zero length if the revision is unknown or invalid.
1.3.6.1.4.1.1916.1.1.1.25DisplayString (SIZE(0..15))read-onlycurrent
extremeDot1dTpFdbTableEnable
OBJECT-TYPE
Setting this to true will cause GetNext operations on the dot1dTpFdbTable to be allowed. Note that Get operations are always allowed.
1.3.6.1.4.1.1916.1.1.1.26TruthValueread-writecurrent
extremePowerSupplyTable
OBJECT-TYPE
Table of status of all power supplies in the system.
1.3.6.1.4.1.1916.1.1.1.27not-accessiblecurrent
extremePowerSupplyEntry
OBJECT-TYPE
An entry indicating the status of a specific power supply.
1.3.6.1.4.1.1916.1.1.1.27.1not-accessiblecurrent
extremePowerSupplyNumber
OBJECT-TYPE
Power supply number.
1.3.6.1.4.1.1916.1.1.1.27.1.1Integer32read-onlycurrent
extremePowerSupplyStatus
OBJECT-TYPE
Status of the power supply.
1.3.6.1.4.1.1916.1.1.1.27.1.2INTEGER {notPresent(1), presentOK(2), presentNotOK(3), presentPowerOff(4)}read-onlycurrent
extremePowerSupplyInputVoltage
OBJECT-TYPE
Input voltage of the power supply
1.3.6.1.4.1.1916.1.1.1.27.1.3PowerValueread-onlycurrent
extremePowerSupplySerialNumber
OBJECT-TYPE
The serial number of the power supply unit.
1.3.6.1.4.1.1916.1.1.1.27.1.4DisplayString (SIZE(0..126))read-onlycurrent
extremePowerSupplyEntPhysicalIndex
OBJECT-TYPE
The entity index for this psu entity in the entityPhysicalTable of the entity MIB.
1.3.6.1.4.1.1916.1.1.1.27.1.5Integer32read-onlycurrent
extremePowerSupplyFan1Speed
OBJECT-TYPE
The speed (RPM) of Fan-1 in the power supply unit.
1.3.6.1.4.1.1916.1.1.1.27.1.6INTEGER {noRPMInfo(-2), notPresent(-1)}read-onlycurrent
extremePowerSupplyFan2Speed
OBJECT-TYPE
The speed (RPM) of Fan-2 in the power supply unit.
1.3.6.1.4.1.1916.1.1.1.27.1.7INTEGER {noRPMInfo(-2), notPresent(-1)}read-onlycurrent
extremePowerSupplySource
OBJECT-TYPE
The power supply unit input source.
1.3.6.1.4.1.1916.1.1.1.27.1.8INTEGER {unknown(1), ac(2), dc(3), externalPowerSupply(4), internalRedundant(5)}read-onlycurrent
extremePowerSupplyInputPowerUsage
OBJECT-TYPE
Input power usage for the given psu slot. The value 0 in this field indicate the power usage is not supported or read failure.
1.3.6.1.4.1.1916.1.1.1.27.1.9Integer32read-onlycurrent
extremePowerMonSupplyNumOutput
OBJECT-TYPE
Number of output sensors in the power supply unit
1.3.6.1.4.1.1916.1.1.1.27.1.10Integer32read-onlycurrent
extremePowerSupplyInputPowerUsageUnitMultiplier
OBJECT-TYPE
The magnitude of watts for the usage value in extremePowerSupplyInputPowerUsage.
1.3.6.1.4.1.1916.1.1.1.27.1.11UnitMultiplierread-onlycurrent
extremeCpuAggregateUtilization
OBJECT-TYPE
The aggregate CPU utilization since the time the start started executing.
1.3.6.1.4.1.1916.1.1.1.28Integer32read-onlydeprecated
extremeCpuTask2Table
OBJECT-TYPE
Table of CPU tasks that are active.
1.3.6.1.4.1.1916.1.1.1.29not-accessibledeprecated
extremeCpuTask2Entry
OBJECT-TYPE
An entry in table of describes a single task.
1.3.6.1.4.1.1916.1.1.1.29.1not-accessibledeprecated
extremeCpuTask2CpuId
OBJECT-TYPE
CPU on which this task last executed or is executing. The primary CPU has a value of 1.
1.3.6.1.4.1.1916.1.1.1.29.1.1Unsigned32not-accessibledeprecated
extremeCpuTask2Name
OBJECT-TYPE
Name associated with the reported task id.
1.3.6.1.4.1.1916.1.1.1.29.1.2DisplayString (SIZE(0..31))not-accessibledeprecated
extremeCpuTask2Id
OBJECT-TYPE
Task identifier assigned by the operating system when this task is spawned.
1.3.6.1.4.1.1916.1.1.1.29.1.3Unsigned32read-onlydeprecated
extremeCpuTask2Pc
OBJECT-TYPE
The value of the program counter for this task. It indicates the address of the next instruction that would be executed once the operating system resumes this task.
1.3.6.1.4.1.1916.1.1.1.29.1.4Unsigned32read-onlydeprecated
extremeCpuTask2Status
OBJECT-TYPE
The current status of the task as reported by the operating system.
1.3.6.1.4.1.1916.1.1.1.29.1.5DisplayStringread-onlydeprecated
extremeCpuTask2Utilization
OBJECT-TYPE
The current CPU utilization by this task. This is the utilization when the task last executed.
1.3.6.1.4.1.1916.1.1.1.29.1.6Unsigned32read-onlydeprecated
extremeCpuTask2MaxUtilization
OBJECT-TYPE
The maximum CPU utilization by this task since the time the start started executing. This value may be cleared.
1.3.6.1.4.1.1916.1.1.1.29.1.7Unsigned32read-writedeprecated
extremeAuthFailSrcAddr
OBJECT-TYPE
The IP address of the originator of the bad SNMP request that caused the generation of an authentication failure trap.
1.3.6.1.4.1.1916.1.1.1.30IpAddressaccessible-for-notifycurrent
extremeCpuTransmitPriority
OBJECT-TYPE
The CPU transmit priority.
1.3.6.1.4.1.1916.1.1.1.31INTEGER {normal(1), high(2)}read-writedeprecated
extremeImageBooted
OBJECT-TYPE
The image with which the switch was last booted, using which it is currently running.
1.3.6.1.4.1.1916.1.1.1.32INTEGER {primary(1), secondary(2)}read-onlycurrent
extremeMsmFailoverCause
OBJECT-TYPE
The cause of the last MSM failover. never(1) means an MSM Failover has not occurred since the last reboot. admin(2) means the failover was initiated by the user. exception(3) means the former master MSM encountered a software exception condition. removal(4) means the master MSM was physically removed from the chassis. hwFailure(5) means a diagnostic failure was detected in the master MSM. watchdog(6) means that the master MSM hardware watchdog timer expired. keepalive(7) means the master MSM failed to respond to slave keepalive requests. The MSM failover will have been hitless only in the admin(2) and exception(3) cases
1.3.6.1.4.1.1916.1.1.1.33INTEGER {never(1), admin(2), exception(3), removal(4), hwFailure(5), watchdog(6), keepalive(7)}read-onlycurrent
extremeImageTable
OBJECT-TYPE
A table containing information about each software image.
1.3.6.1.4.1.1916.1.1.1.34not-accessiblecurrent
extremeImageEntry
OBJECT-TYPE
A table entry containing information about each software image.
1.3.6.1.4.1.1916.1.1.1.34.1not-accessiblecurrent
extremeImageNumber
OBJECT-TYPE
A unique integer identifying the particular software image.
1.3.6.1.4.1.1916.1.1.1.34.1.1INTEGER {cur(0), pri(1), sec(2), curr(3)}read-onlycurrent
extremeMajorVersion
OBJECT-TYPE
The ExtremeWare Release Major Version.
1.3.6.1.4.1.1916.1.1.1.34.1.2Integer32read-onlycurrent
extremeSubMajorVersion
OBJECT-TYPE
The ExtremeWare Release Sub-major Version.
1.3.6.1.4.1.1916.1.1.1.34.1.3Integer32read-onlydeprecated
extremeMinorVersion
OBJECT-TYPE
The ExtremeWare Release Minor Version.
1.3.6.1.4.1.1916.1.1.1.34.1.4Integer32read-onlycurrent
extremeBuildNumber
OBJECT-TYPE
The ExtremeWare Build Number.
1.3.6.1.4.1.1916.1.1.1.34.1.5Integer32read-onlycurrent
extremeTechnologyReleaseNumber
OBJECT-TYPE
The Technology Release version. This value is zero for all but TR releases.
1.3.6.1.4.1.1916.1.1.1.34.1.6Integer32read-onlycurrent
extremeSustainingReleaseNumber
OBJECT-TYPE
The Sustaining Release number for the ExtremeWare version.
1.3.6.1.4.1.1916.1.1.1.34.1.7Integer32read-onlycurrent
extremeBranchRevisionNumber
OBJECT-TYPE
The incremental build on specified branch.
1.3.6.1.4.1.1916.1.1.1.34.1.8Integer32read-onlycurrent
extremeImageType
OBJECT-TYPE
The branch type from which the image was built.
1.3.6.1.4.1.1916.1.1.1.34.1.9INTEGER {trunk(0), branch(1), patch(2), technology(3), beta(4)}read-onlycurrent
extremeImageDescription
OBJECT-TYPE
A unique string that can be used to identify the specific patch, technology, or development branch release.
1.3.6.1.4.1.1916.1.1.1.34.1.10DisplayString (SIZE(0..255))read-onlycurrent
extremeImageSecurity
OBJECT-TYPE
Indicates whether image was built with ssh. This object is deprecated, the ssh capability can be obtained from the extremeImageSshCapability of the ImageFeatureTable
1.3.6.1.4.1.1916.1.1.1.34.1.11INTEGER {unknown(0), nossh(1), ssh(2)}read-onlydeprecated
extremePatchVersion
OBJECT-TYPE
The ExtremeWare Release Patch Version.
1.3.6.1.4.1.1916.1.1.1.34.1.12Integer32read-onlycurrent
extremeImageFeatureTable
OBJECT-TYPE
A table containing information about the software features.
1.3.6.1.4.1.1916.1.1.1.35not-accessiblecurrent
extremeImageFeatureEntry
OBJECT-TYPE
A table entry containing information about software features.
1.3.6.1.4.1.1916.1.1.1.35.1not-accessiblecurrent
extremeImageFeatureNumber
OBJECT-TYPE
A unique integer identifying the particular software image.
1.3.6.1.4.1.1916.1.1.1.35.1.1INTEGER {cur(0), pri(1), sec(2)}read-onlycurrent
extremeImageSshCapability
OBJECT-TYPE
Indicates whether image has ssh capability.
1.3.6.1.4.1.1916.1.1.1.35.1.2INTEGER {unknown(0), nossh(1), ssh(2)}read-onlycurrent
extremeImageUAACapability
OBJECT-TYPE
Indicates whether image has Wireless(UAA) components.
1.3.6.1.4.1.1916.1.1.1.35.1.3INTEGER {unknown(0), nouaa(1), uaa(2)}read-onlycurrent
extremeSystemPowerState
OBJECT-TYPE
The current state of power available.
1.3.6.1.4.1.1916.1.1.1.36INTEGER {computing(1), sufficientButNotRedundantPower(2), redundantPowerAvailable(3), insufficientPower(4)}read-onlycurrent
extremeBootTime
OBJECT-TYPE
The boot time expressed in standard time_t value. When interpreted as an absolute time value, it represents the number of seconds elapsed since 00:00:00 on January 1, 1970, Coordinated Universal Time (UTC)
1.3.6.1.4.1.1916.1.1.1.37Counter64read-onlycurrent
extremePowerSupplyOutputPowerTable
OBJECT-TYPE
The output power supply table per power supply unit.
1.3.6.1.4.1.1916.1.1.1.38not-accessiblecurrent
extremePowerSupplyOutputPowerEntry
OBJECT-TYPE
An entry in the power supply output table.
1.3.6.1.4.1.1916.1.1.1.38.1not-accessiblecurrent
extremePowerSupplyIndex
OBJECT-TYPE
Power supply unit slot index
1.3.6.1.4.1.1916.1.1.1.38.1.1Integer32read-onlycurrent
extremePowerSupplyOutputSensorIdx
OBJECT-TYPE
Power supply Sensor Index
1.3.6.1.4.1.1916.1.1.1.38.1.2Integer32read-onlycurrent
extremePowerSupplyOutputVoltage
OBJECT-TYPE
Output voltage per sensor for the current psu slot no. 0 in this field tells the psu doesnt support output voltage reading or output voltage read error.
1.3.6.1.4.1.1916.1.1.1.38.1.3Integer32read-onlycurrent
extremePowerSupplyOutputCurrent
OBJECT-TYPE
Output current per sensor for the current psu slot no. 0 in this field tells the psu doesnt support output current reading or output current read error.
1.3.6.1.4.1.1916.1.1.1.38.1.4Integer32read-onlycurrent
extremePowerSupplyOutputUnitMultiplier
OBJECT-TYPE
The magnitude of volts and amps for the usage value in extremePowerSupplyOutputVoltage and extremePowerSupplyOutputCurrent.
1.3.6.1.4.1.1916.1.1.1.38.1.5UnitMultiplierread-onlycurrent
extremePowerSupplyUsageTable
OBJECT-TYPE
The power supply usage on each slot.
1.3.6.1.4.1.1916.1.1.1.39not-accessiblecurrent
extremePowerSupplyUsageEntry
OBJECT-TYPE
An entry in the power supply usage table.
1.3.6.1.4.1.1916.1.1.1.39.1not-accessiblecurrent
extremeSlotIndex
OBJECT-TYPE
Slot number in the chassis/stack based system.
1.3.6.1.4.1.1916.1.1.1.39.1.1Integer32read-onlycurrent
extremePowerSupplyUsageValue
OBJECT-TYPE
Power Usage of the particular slot in the chassis or stack.The power usage is measured in milli-watts.
1.3.6.1.4.1.1916.1.1.1.39.1.2Integer32read-onlycurrent
extremePowerSupplyUnitMultiplier
OBJECT-TYPE
The magnitude of watts for the usage value in extremePowerSupplyUsageValue.
1.3.6.1.4.1.1916.1.1.1.39.1.3UnitMultiplierread-onlycurrent
extremeSystemPowerUsage
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.1.40
extremeSystemPowerUsageValue
OBJECT-TYPE
The current power usage of the system.In stack mode this variables tells total power usage of the entire system.
1.3.6.1.4.1.1916.1.1.1.40.1Integer32read-onlycurrent
extremeSystemPowerUsageUnitMultiplier
OBJECT-TYPE
The magnitude of watts for the usage value in extremeSystemPowerUsageValue.
1.3.6.1.4.1.1916.1.1.1.40.2UnitMultiplierread-onlycurrent
extremeSystemPowerMonitorTable
OBJECT-TYPE
The output power supply table per power supply unit.
1.3.6.1.4.1.1916.1.1.1.41not-accessiblecurrent
extremeSystemPowerMonitorEntry
OBJECT-TYPE
An entry in the power supply output table.
1.3.6.1.4.1.1916.1.1.1.41.1not-accessiblecurrent
extremeSystemPowerMonitorIndex1
OBJECT-TYPE
Reserved can be used for future expansion. currently set to zero.
1.3.6.1.4.1.1916.1.1.1.41.1.1Integer32read-onlycurrent
extremeSystemPowerMonitorPollInterval
OBJECT-TYPE
Configure how often input power is measured. it is configured in seconds. default value is 60 seconds. if 0 is configured then the input power measurement is disabled
1.3.6.1.4.1.1916.1.1.1.41.1.2INTEGER (0..300)read-writecurrent
extremeSystemPowerMonitorReportChanges
OBJECT-TYPE
configure report-changes has none or log or trap or log-and-trap, by default none is configured
1.3.6.1.4.1.1916.1.1.1.41.1.3INTEGER {none(1), log(2), trap(3), logandtrap(4)}read-writecurrent
extremeSystemPowerMonitorChangeThreshold
OBJECT-TYPE
configure input power change-threshold to initiate report-changes action. By default 2 watts is configured, this field is configured in watts.
1.3.6.1.4.1.1916.1.1.1.41.1.4Integer32read-writecurrent
extremeRebootTable
OBJECT-TYPE
This group of objects use to initiate a device reboot or contain details of the last reboot operation of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.42not-accessiblecurrent
rebootTimeEntry
OBJECT-TYPE
This group of objects use to initiate a device reboot or contain details of the last reboot operation of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.42.1not-accessiblecurrent
extremeRebootSlotId
OBJECT-TYPE
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
1.3.6.1.4.1.1916.1.1.1.42.1.1INTEGER (0..65535)read-onlycurrent
extremeRebootNodeAddress
OBJECT-TYPE
Specifies the MAC address of the SummitStack node to be rebooted. NOTE: This object is valid only for Summit X250e and X450 series switches, and SummitStack.
1.3.6.1.4.1.1916.1.1.1.42.1.2MacAddressread-writecurrent
extremeRebootModuleSlotId
OBJECT-TYPE
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
1.3.6.1.4.1.1916.1.1.1.42.1.3DisplayStringread-writecurrent
extremeRebootSlotNumber
OBJECT-TYPE
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on SummitStack.
1.3.6.1.4.1.1916.1.1.1.42.1.4Integer32read-writecurrent
extremeRebootAsStandby
OBJECT-TYPE
Specifies that all stack nodes that are to be rebooted are to operate as if configured to not be master-capable. NOTE: This object is valid only for Summit X250e and X450 series switches and SummitStack.
1.3.6.1.4.1.1916.1.1.1.42.1.5INTEGER {disabled(0), enabled(1)}read-writecurrent
extremeRebootStackTopology
OBJECT-TYPE
Specifies that the entire SummitStack is to be rebooted whether or not nodes are active. NOTE: This object is valid only for Summit X250e and X450 series switches and SummitStack.
1.3.6.1.4.1.1916.1.1.1.42.1.6INTEGER {disabled(0), enabled(1)}read-writecurrent
extremeRebootMonth
OBJECT-TYPE
Specifies the month that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.7INTEGER (1..12)read-writecurrent
extremeRebootDay
OBJECT-TYPE
Specifies the day that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.8INTEGER (1..31)read-writecurrent
extremeRebootYear
OBJECT-TYPE
Specifies the year that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.9INTEGER (2003..2036)read-writecurrent
extremeRebootHour
OBJECT-TYPE
Specifies the hour that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.10INTEGER (0..23)read-writecurrent
extremeRebootMinute
OBJECT-TYPE
Specifies the number of minutes that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.11INTEGER (0..59)read-writecurrent
extremeRebootSeconds
OBJECT-TYPE
Specifies the number of seconds that the reboot is scheduled to start.
1.3.6.1.4.1.1916.1.1.1.42.1.12INTEGER (0..59)read-writecurrent
extremeRebootCancel
OBJECT-TYPE
Cancels a previously scheduled reboot. Note: This object, when enabled, override all objects associated with a reboot request.
1.3.6.1.4.1.1916.1.1.1.42.1.13INTEGER {disabled(0), enabled(1)}read-writecurrent
extremeRebootImmediate
OBJECT-TYPE
Indicates that a reboot should be executed on the target device immediately.
1.3.6.1.4.1.1916.1.1.1.42.1.14INTEGER {disabled(0), enabled(1)}read-writecurrent
extremeRebootRowStatus
OBJECT-TYPE
The existence state of this reboot request. This object follows the row status behavior.
1.3.6.1.4.1.1916.1.1.1.42.1.15RowStatusread-createcurrent
extremeDownloadImageTable
OBJECT-TYPE
This group of objects contain details of the last or the current download image operation of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.43not-accessiblecurrent
extremeDownloadImageEntry
OBJECT-TYPE
This group of objects contain details of the last or the current download image operation of one of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.43.1not-accessiblecurrent
extremeDownloadImageSlotId
OBJECT-TYPE
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
1.3.6.1.4.1.1916.1.1.1.43.1.1INTEGER (0..65535)read-createcurrent
extremeDownloadImageStatus
OBJECT-TYPE
Specifies the status of the current down load operation.
1.3.6.1.4.1.1916.1.1.1.43.1.2INTEGER {downloadInProgress(1), downloadOperationSuccess(2), downloadNotMaster(3), downloadNameLengthError(4), downloadInvalidFileType(5), downloadActivePartitionError(6), downloadIllegalHostname(7), downloadFailed(8), downloadInvalidIpaddr(9), downloadMemAllocFailed(10), downloadNotInActiveTop(11), downloadMissingFileName(12), downloadIllegalFileName(13), downloadOperationTimeout(14), downloadInvalidRowStatus(15)}read-createcurrent
extremeDownloadImageFilename
OBJECT-TYPE
Specifies the file name of the downloading EXOS image.
1.3.6.1.4.1.1916.1.1.1.43.1.3DisplayString (SIZE(0..128))read-createcurrent
extremeDownloadImagePartition
OBJECT-TYPE
Specifies which partition the image should be saved to primary or secondary. Select primary to save the image to the primary partition and secondary to save the image to the secondary partition. Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core image must be installed on the alternate (nonactive) partition. If a user tries to install on an active partition, the error message [Error: Image can only be installed to the non-active partition.] is displayed.
1.3.6.1.4.1.1916.1.1.1.43.1.4INTEGER {primary(1), secondary(2)}read-createcurrent
extremeDownloadImageHostName
OBJECT-TYPE
Specifies the hostname of the TFTP server from which the image should be obtained.
1.3.6.1.4.1.1916.1.1.1.43.1.5DisplayString (SIZE(0..128))read-createcurrent
extremeDownloadImageIpaddress
OBJECT-TYPE
Specifies the IP address of the TFTP server from which the image should be obtained.
1.3.6.1.4.1.1916.1.1.1.43.1.6DisplayString (SIZE(0..128))read-createcurrent
extremeDownloadImageStartTime
OBJECT-TYPE
Specifies the start time (date and time) of the current down load operation.
1.3.6.1.4.1.1916.1.1.1.43.1.7DisplayString (SIZE(0..31))read-createcurrent
extremeDownloadImageMemorycard
OBJECT-TYPE
Specifies that the image should be obtained from a removable storage device, which can be a compact flash card or a USB 2.0 storage device.
1.3.6.1.4.1.1916.1.1.1.43.1.8INTEGER {disabled(0), enabled(1)}read-createcurrent
extremeDownloadImageInstall
OBJECT-TYPE
Specifies to start the install process after the successful download of the image.
1.3.6.1.4.1.1916.1.1.1.43.1.9INTEGER {disabled(0), enabled(1)}read-createcurrent
extremeDownloadSlotNumber
OBJECT-TYPE
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on stackable switches in a stack.
1.3.6.1.4.1.1916.1.1.1.43.1.10INTEGER (1..8)read-createcurrent
extremeDownloadModuleSlotId
OBJECT-TYPE
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
1.3.6.1.4.1.1916.1.1.1.43.1.11DisplayStringread-createcurrent
extremeDownloadRowStatus
OBJECT-TYPE
The existence state of this download image request. This object follows the row status behavior.
1.3.6.1.4.1.1916.1.1.1.43.1.12RowStatusread-createcurrent
extremeInstallImageTable
OBJECT-TYPE
This group of objects contain details of the last or the current install image operation of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.44not-accessiblecurrent
extremeInstallImageEntry
OBJECT-TYPE
This group of objects contain details of the last or the current install image operation of one of the switch modules or nodes.
1.3.6.1.4.1.1916.1.1.1.44.1not-accessiblecurrent
extremeInstallImageSlotId
OBJECT-TYPE
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
1.3.6.1.4.1.1916.1.1.1.44.1.1INTEGER (0..65535)read-onlycurrent
extremeInstallImageStatus
OBJECT-TYPE
Specifies the status of the current install image operation.
1.3.6.1.4.1.1916.1.1.1.44.1.2INTEGER {installInProgress(1), installOperationSuccess(2), installOperationPending(3), installNameLengthError(4), installInvalidFileType(5), installActivePartitionError(6), installDwnloadSlotMismatch(7), installFailed(8), installNotPrimary(9), installMemAllocFailed(10), installNotInActiveTop(11), installMissingFileName(12), installIllegalFileName(13), installOperationTimeout(14), installOperBackupTimeout(15), installInvalidRowStatus(16)}read-onlycurrent
extremeInstallImageFilename
OBJECT-TYPE
Specifies the software image file.
1.3.6.1.4.1.1916.1.1.1.44.1.3DisplayString (SIZE(0..128))read-writecurrent
extremeInstallImagePartition
OBJECT-TYPE
Specifies which partition the image should be saved to: primary or secondary. Select primary to save the image to the primary partition and secondary to save the image to the secondary partition. Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core image must be installed on the alternate (nonactive) partition. If a user tries to install on an active partition, the error message [Error: Image can only be installed to the non-active partition.] is displayed.
1.3.6.1.4.1.1916.1.1.1.44.1.4INTEGER {primary(1), secondary(2)}read-writecurrent
extremeInstallImageStartTime
OBJECT-TYPE
Specifies the start time of the current install operation.
1.3.6.1.4.1.1916.1.1.1.44.1.5DisplayString (SIZE(0..31))read-onlycurrent
extremeInstallImageReboot
OBJECT-TYPE
Specifies to reboot the switch after the image is installed.
1.3.6.1.4.1.1916.1.1.1.44.1.6INTEGER {disabled(0), enabled(1)}read-writecurrent
extremeInstallImageModuleSlotId
OBJECT-TYPE
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
1.3.6.1.4.1.1916.1.1.1.44.1.7DisplayStringread-writecurrent
extremeInstallImageSlotNumber
OBJECT-TYPE
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on stackable switches in a stack.
1.3.6.1.4.1.1916.1.1.1.44.1.8INTEGER (1..8)read-writecurrent
extremeInstallImageRowStatus
OBJECT-TYPE
The existence state of this install image request. This object follows the row status behavior.
1.3.6.1.4.1.1916.1.1.1.44.1.9RowStatusread-createcurrent
extremeLoadInstallTrap
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.1.45
loadInstallControl
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.1.45.1
downloadImageTrapEnable
OBJECT-TYPE
This variable indicates whether the system produces the downloadImageTrap notification. A no(2) value will prevent notifications from being generated by this system.
1.3.6.1.4.1.1916.1.1.1.45.1.1INTEGER {yes(1), no(2)}read-writecurrent
installImageTrapEnable
OBJECT-TYPE
This variable indicates whether the system produces the extremeInstallImageTrap notification. A no(2) value will prevent notifications from being generated by this system.
1.3.6.1.4.1.1916.1.1.1.45.1.2INTEGER {yes(1), no(2)}read-writecurrent
loadInstallTraps
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.1.45.2
extremeSaveConfigurationFileName
OBJECT-TYPE
This object is set, along the object extremSaveConfiguration option with value 5.This object indicates the file name to be used while saving the file. On reading it returns the current selected config.
1.3.6.1.4.1.1916.1.1.1.48DisplayString (SIZE(0..127))read-writecurrent
extremeUseOnRebootFileName
OBJECT-TYPE
This object is set, along the object extremeConfigToUseOnReboot option with value 3.This object indicates the file name to be used while saving the file
1.3.6.1.4.1.1916.1.1.1.49DisplayString (SIZE(0..127))read-writecurrent
extremeChassisGroup
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.2
extremeMasterMSMSlot
OBJECT-TYPE
The extremeSlotNumber of the master MSM module.
1.3.6.1.4.1.1916.1.1.2.1Integer32read-onlycurrent
extremeSlotTable
OBJECT-TYPE
A table containing information about each slot in the chassis.
1.3.6.1.4.1.1916.1.1.2.2not-accessiblecurrent
extremeSlotEntry
OBJECT-TYPE
A table entry containing information about the module in each slot of the chassis.
1.3.6.1.4.1.1916.1.1.2.2.1not-accessiblecurrent
extremeSlotNumber
OBJECT-TYPE
A unique integer identifying the particular slot in the chassis.
1.3.6.1.4.1.1916.1.1.2.2.1.1Integer32read-onlycurrent
extremeSlotName
OBJECT-TYPE
A name identifying the particular slot in the chassis.
1.3.6.1.4.1.1916.1.1.2.2.1.2DisplayStringread-onlycurrent
extremeSlotModuleConfiguredType
OBJECT-TYPE
The configured module type for the given slot. At startup, the module-type is none(1). It is possible to configure the module-type even if there is no module in the slot. If the current module in the slot is different than the requested configured module-type, then the current configuration for the module is erased and the card will be restarted. The new configured module-type will be recorded. Since the configured module type is different than the actual module type, a moduleMismatch trap will be sent, and the extremeSlotModuleState for that module will show a mismatch(3). Setting this variable to none(1) will clear the previously assigned module-type of this slot, and all configuration information related to the slot will be erased.
1.3.6.1.4.1.1916.1.1.2.2.1.3SlotTyperead-writecurrent
extremeSlotModuleInsertedType
OBJECT-TYPE
The module type inserted into the slot. It is possible to have a slot inserted into the slot even though extremeSlotConfiguredType is none(1).
1.3.6.1.4.1.1916.1.1.2.2.1.4SlotTyperead-onlycurrent
extremeSlotModuleState
OBJECT-TYPE
The state of the module inserted in this slot.
1.3.6.1.4.1.1916.1.1.2.2.1.5INTEGER {notPresent(1), testing(2), mismatch(3), failed(4), operational(5), powerdown(6), unknown(7), present(8), poweron(9), post(10), downloading(11), booting(12), offline(13), initializing(14), invalid(100)}read-onlycurrent
extremeSlotModuleSerialNumber
OBJECT-TYPE
The serial number of the module inserted in this slot.
1.3.6.1.4.1.1916.1.1.2.2.1.6DisplayStringread-onlycurrent
extremeChassisPortsPerSlot
OBJECT-TYPE
The maximum number of ports that can be accomodated in a single slot. This number would change to accomodate blades with higher port density than current ones.
1.3.6.1.4.1.1916.1.1.2.3Integer32read-onlycurrent
extremeSystemHealthCheck
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.3
extremeHealthCheckErrorType
OBJECT-TYPE
The error reported in the system health check trap
1.3.6.1.4.1.1916.1.1.3.1INTEGER {unknown(1), cpuPacket(2), backplane(3), hardwareFail(4), pbusChecksum(5)}accessible-for-notifycurrent
extremeHealthCheckAction
OBJECT-TYPE
The action/alarm level configured for health check.
1.3.6.1.4.1.1916.1.1.3.2INTEGER {syslogOnly(1), healthCheckTrap(2), ioModuleDown(3), systemDown(4), autoRecovery(5)}read-onlycurrent
extremeHealthCheckMaxRetries
OBJECT-TYPE
The maximum number of times a module restart will be attempted if it fails. If extremeHealthCheckAction is not autorecovery(5), then this value is zero.
1.3.6.1.4.1.1916.1.1.3.3Integer32read-onlycurrent
extremeSystemThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.4
extremeCpuUtilRisingThreshold
OBJECT-TYPE
Rising threshold for CPU Aggregation utilization trap
1.3.6.1.4.1.1916.1.1.4.1INTEGER (0..100)read-writedeprecated
extremeCpuTaskUtilPair
OBJECT-TYPE
TaskName/CPU_% Util pair reported in CPU Utilization trap
1.3.6.1.4.1.1916.1.1.4.2DisplayStringaccessible-for-notifydeprecated
extremeSystemNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.6
extremeSystemTrapsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.6.0
extremeGenericTrapParams
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.1.7
severity
OBJECT-TYPE
The severity of the message being sent.
1.3.6.1.4.1.1916.1.1.7.1INTEGER {critical(1), error(2), warning(3), notice(4), info(5), debug-summary(6), debug-verbose(7), debug-data(8)}accessible-for-notifycurrent
eventName
OBJECT-TYPE
The event name being sent.
1.3.6.1.4.1.1916.1.1.7.2DisplayString (SIZE(0..40))accessible-for-notifycurrent
message
OBJECT-TYPE
The message being sent
1.3.6.1.4.1.1916.1.1.7.3DisplayString (SIZE(0..256))accessible-for-notifycurrent

Notifications

NameOIDStatus
downloadImageTrap
NOTIFICATION-TYPE
This notification indicates the status of the last/current download operation.
1.3.6.1.4.1.1916.1.1.1.45.2.1current
installImageTrap
NOTIFICATION-TYPE
This notification indicates the status of the last/current install operation.
1.3.6.1.4.1.1916.1.1.1.45.2.2current
extremeSystemPowerStatus
NOTIFICATION-TYPE
Change in status of System Power The trap will not be generated for discovering state.
1.3.6.1.4.1.1916.1.1.6.0.1current
extremeGenericTrap
NOTIFICATION-TYPE
Some event took place in the system
1.3.6.1.4.1.1916.1.1.6.0.2current
extremePsuPowerStatus
NOTIFICATION-TYPE
Trap to indicate change in status of Power Supply.
1.3.6.1.4.1.1916.1.1.6.0.3current
extremeSystemPowerUsageNotification
NOTIFICATION-TYPE
Whenever the power usage is increased/decreased by the configured threshold value then the power usage trap is generated if the trap is enabled..
1.3.6.1.4.1.1916.1.1.6.0.4current