EPPC-MIB
- Registered at
- 1.3.6.1.4.1.935
- Namespace
- powerwalker
- Source file
EPPC-MIB- Digest
sha256:a875e828b4c184a6b1716ac7b5850d724277498615c941556a7638f78aa4f658
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
| UPS-MIB | NonNegativeInteger, PositiveInteger |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
EPPC-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UPS-MIB
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.935.1 | products | XPPC-MIB |
| 1.3.6.1.4.1.935.2 | ppcmgmt | XPPC-MIB |
| 1.3.6.1.4.1.935.10 | device |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ppc OBJECT-IDENTITY | 1.3.6.1.4.1.935 | |||
| device OBJECT-IDENTITY | 1.3.6.1.4.1.935.10 | |||
| upsAgent OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1 | |||
| upsE OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1 | |||
| upsEIdentity OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.1 | |||
| upsEIdentityManufacturer OBJECT-TYPE The name of the UPS manufacturer. | 1.3.6.1.4.1.935.10.1.1.1.1 | DisplayString (SIZE(0..31)) | read-only | mandatory |
| upsEIdentityModel OBJECT-TYPE The UPS Model designation. | 1.3.6.1.4.1.935.10.1.1.1.2 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| upsEIdentityUPSFirmwareVerison OBJECT-TYPE The UPS firmware/software version(s). | 1.3.6.1.4.1.935.10.1.1.1.3 | DisplayString (SIZE(0..31)) | read-only | mandatory |
| upsEIndentityUPSSerialNumber OBJECT-TYPE optional. Most UPS don't supply the value of UPS serial No. | 1.3.6.1.4.1.935.10.1.1.1.4 | DisplayString (SIZE(0..31)) | read-only | mandatory |
| upsEIdentityDescription OBJECT-TYPE A string to identify the UPS. This object should be set by the administrator. | 1.3.6.1.4.1.935.10.1.1.1.5 | DisplayString (SIZE(0..63)) | read-write | mandatory |
| upsEIdentityAgentSoftwareVerison OBJECT-TYPE The Network Management Card software/firmware version. This variable may or may not have the same value as upsEIdentGroupUPSSoftwareVersion in some implementations. | 1.3.6.1.4.1.935.10.1.1.1.6 | DisplayString (SIZE(0..31)) | read-only | mandatory |
| upsEIdentityAttachedDevices OBJECT-TYPE A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator | 1.3.6.1.4.1.935.10.1.1.1.7 | DisplayString (SIZE(0..63)) | read-write | mandatory |
| upsESystemSummary OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.2 | |||
| upsESystemStatus OBJECT-TYPE The indication of UPS system status. | 1.3.6.1.4.1.935.10.1.1.2.1 | INTEGER {power-on(1), stand-by(2), by-pass(3), line(4), battery(5), battery-test(6), fault(7), converter(8), eco(9), shutdown(10), on-booster(11), on-reducer(12), other(13)} | read-only | mandatory |
| upsESystemTemperature OBJECT-TYPE The temperature of UPS presented in 0.1 degree. | 1.3.6.1.4.1.935.10.1.1.2.2 | INTEGER | read-only | mandatory |
| upsESystemWarningCode OBJECT-TYPE The warning code of UPS. Please refer the warning table of 'Q6' for details. | 1.3.6.1.4.1.935.10.1.1.2.3 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| upsESystemFaultCode OBJECT-TYPE The fault code of UPS.Please refer the fault code of 'Q6' for details. | 1.3.6.1.4.1.935.10.1.1.2.4 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| upsESystemConfigInputVoltage OBJECT-TYPE The magnitude of the nominal input voltage presented in 0.1 V. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | 1.3.6.1.4.1.935.10.1.1.2.5 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigInputFrequence OBJECT-TYPE The nominal input frequency presented in 0.1 Hz. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | 1.3.6.1.4.1.935.10.1.1.2.6 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigOutputVoltage OBJECT-TYPE The magnitude of the nominal output voltage presented in 0.1V. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2 | 1.3.6.1.4.1.935.10.1.1.2.7 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigOutputFrequency OBJECT-TYPE The nominal output frequency presented in 0.1Hz. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | 1.3.6.1.4.1.935.10.1.1.2.8 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigOutputVA OBJECT-TYPE The magnitude of the nominal Volt-Amp rating presented in VA. | 1.3.6.1.4.1.935.10.1.1.2.9 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigOutputPower OBJECT-TYPE The magnitude of the nominal true power rating presented in W . | 1.3.6.1.4.1.935.10.1.1.2.10 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigOutputLoadHighSetPoint OBJECT-TYPE The maximum output load allowed before the load is too high for UPS operation | 1.3.6.1.4.1.935.10.1.1.2.11 | NonNegativeInteger | read-write | mandatory |
| upsESystemConfigOverTemperatureSetPoint OBJECT-TYPE The maximum temperature allowed before the UPS operation temperature is too high, presented in 0.1 degree. | 1.3.6.1.4.1.935.10.1.1.2.12 | NonNegativeInteger | read-write | mandatory |
| upsESystemInputSourceNum OBJECT-TYPE The present external source of input power. | 1.3.6.1.4.1.935.10.1.1.2.13 | INTEGER | read-only | mandatory |
| upsESystemInputLineBads OBJECT-TYPE The number of times the Input was out of tolerance in voltage or frequency. Its value should be initialized 0 after agent restarting. | 1.3.6.1.4.1.935.10.1.1.2.14 | Counter | read-only | mandatory |
| upsESystemInputNumPhases OBJECT-TYPE The number of input phase utilized is this device, serves as the table index. This value indicate the device initialized feature. | 1.3.6.1.4.1.935.10.1.1.2.15 | PositiveInteger (1..3) | read-only | mandatory |
| upsESystemInputTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of upsESystemInputNumPhase. | 1.3.6.1.4.1.935.10.1.1.2.16 | not-accessible | mandatory | |
| upsESystemInputEntry OBJECT-TYPE An entry containing information applicable to a particular input line. | 1.3.6.1.4.1.935.10.1.1.2.16.1 | not-accessible | mandatory | |
| upsESystemInputPhase OBJECT-TYPE The number of the phase. Serves as index for input table | 1.3.6.1.4.1.935.10.1.1.2.16.1.1 | PositiveInteger (1..3) | not-accessible | mandatory |
| upsESystemInputFrequency OBJECT-TYPE The measured input frquency from the UPS meters in 0.1Hz. | 1.3.6.1.4.1.935.10.1.1.2.16.1.2 | NonNegativeInteger | read-only | mandatory |
| upsESystemInputVoltage OBJECT-TYPE The measured input voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.2.16.1.3 | NonNegativeInteger | read-only | mandatory |
| upsESystemInputCurrent OBJECT-TYPE The measured input mandatory from the UPS meters in 0.1 amps. | 1.3.6.1.4.1.935.10.1.1.2.16.1.4 | NonNegativeInteger | read-only | mandatory |
| upsESystemInputWatts OBJECT-TYPE The measured input real power in watts. | 1.3.6.1.4.1.935.10.1.1.2.16.1.5 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputNumPhase OBJECT-TYPE The number of metered output phases, serves as the table index. This value indicate the device initialized feature. | 1.3.6.1.4.1.935.10.1.1.2.17 | PositiveInteger (1..3) | read-only | mandatory |
| upsESystemOutputTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of upsESystemOutputNumPhase. | 1.3.6.1.4.1.935.10.1.1.2.18 | not-accessible | mandatory | |
| upsESystemOutputEntry OBJECT-TYPE An entry containing information applicable to a particular line. | 1.3.6.1.4.1.935.10.1.1.2.18.1 | not-accessible | mandatory | |
| upsESystemOutputPhase OBJECT-TYPE The number of the phase. Serves as index for output table | 1.3.6.1.4.1.935.10.1.1.2.18.1.1 | PositiveInteger (1..3) | not-accessible | mandatory |
| upsESystemOutputFrequency OBJECT-TYPE The measured output frequency from the UPS meters in 0.1Hz. | 1.3.6.1.4.1.935.10.1.1.2.18.1.2 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputVoltage OBJECT-TYPE The measured output voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.2.18.1.3 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputCurrent OBJECT-TYPE The measured output mandatory from the UPS meters in 0.1 amps. | 1.3.6.1.4.1.935.10.1.1.2.18.1.4 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputWatts OBJECT-TYPE The measured output real power in watts. | 1.3.6.1.4.1.935.10.1.1.2.18.1.5 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputVA OBJECT-TYPE The measured output real complex power in VA. | 1.3.6.1.4.1.935.10.1.1.2.18.1.6 | NonNegativeInteger | read-only | mandatory |
| upsESystemOutputLoad OBJECT-TYPE The UPS output load in percent of rated capacity. | 1.3.6.1.4.1.935.10.1.1.2.18.1.7 | NonNegativeInteger | read-only | mandatory |
| upsESystemBypassNumPhase OBJECT-TYPE The number of bypass phases, serves as the table index. This value indicate the device initialized feature | 1.3.6.1.4.1.935.10.1.1.2.19 | PositiveInteger (1..3) | read-only | mandatory |
| upsESystemBypassTable OBJECT-TYPE A list of bypass table entries. The number of entries is given by the value of upsESystemBypassNumPhase. | 1.3.6.1.4.1.935.10.1.1.2.20 | not-accessible | mandatory | |
| upsESystemBypassEntry OBJECT-TYPE An entry containing information applicable to a particular line. | 1.3.6.1.4.1.935.10.1.1.2.20.1 | not-accessible | mandatory | |
| upsESystemBypassPhase OBJECT-TYPE The number of the phase. Serves as index for bypass table | 1.3.6.1.4.1.935.10.1.1.2.20.1.1 | PositiveInteger (1..3) | not-accessible | mandatory |
| upsESystemBypassFrequency OBJECT-TYPE The measured bypass frequency from the UPS meters in 0.1 Hz. | 1.3.6.1.4.1.935.10.1.1.2.20.1.2 | NonNegativeInteger | read-only | mandatory |
| upsESystemBypassVoltage OBJECT-TYPE The measured bypass voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.2.20.1.3 | NonNegativeInteger | read-only | mandatory |
| upsESystemBypassCurrent OBJECT-TYPE The measured bypass mandatory from the UPS meters in 0.1 amps | 1.3.6.1.4.1.935.10.1.1.2.20.1.4 | NonNegativeInteger | read-only | mandatory |
| upsESystemBypassWatts OBJECT-TYPE The measured input real power in watts. | 1.3.6.1.4.1.935.10.1.1.2.20.1.5 | NonNegativeInteger | read-only | mandatory |
| upsESystemConfigBelowCapacityLimit OBJECT-TYPE The UPS batteries capacity(%) limit for shutdown | 1.3.6.1.4.1.935.10.1.1.2.21 | NonNegativeInteger | read-write | mandatory |
| upsESystemConfigBelowRemainTimeLimit OBJECT-TYPE The UPS batteries backup time(minute) limit for shutdown | 1.3.6.1.4.1.935.10.1.1.2.22 | NonNegativeInteger | read-write | mandatory |
| upsEBatterySystem OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.3 | |||
| upsEBatteryStatus OBJECT-TYPE The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output) | 1.3.6.1.4.1.935.10.1.1.3.1 | INTEGER {unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4), batteryDischarging(5), batteryFailure(6)} | read-only | mandatory |
| upsESecondsOnBattery OBJECT-TYPE If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. 0 shall be returned if the unit is not on battery power | 1.3.6.1.4.1.935.10.1.1.3.2 | NonNegativeInteger | read-only | mandatory |
| upsEBatteryEstimatedMinutesRemaining OBJECT-TYPE An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. | 1.3.6.1.4.1.935.10.1.1.3.3 | PositiveInteger | read-only | mandatory |
| upsEBatteryEstimatedChargeRemaining OBJECT-TYPE An estimate of the battery charge remaining expressed as a percent of full charge | 1.3.6.1.4.1.935.10.1.1.3.4 | Integer32 (0..100) | read-only | mandatory |
| upsEPositiveBatteryVoltage OBJECT-TYPE The magnitude of the present positive battery voltage in 0.1 Volt DC | 1.3.6.1.4.1.935.10.1.1.3.5 | NonNegativeInteger | read-only | mandatory |
| upsENegativeBatteryVoltage OBJECT-TYPE The magnitude of the present negative battery voltage in 0.1 Volt DC | 1.3.6.1.4.1.935.10.1.1.3.6 | NonNegativeInteger | read-only | mandatory |
| upsEBatteryCellNumber OBJECT-TYPE This object indicate the cell number of each set. | 1.3.6.1.4.1.935.10.1.1.3.7 | NonNegativeInteger | read-only | mandatory |
| upsEBatteryTemperature OBJECT-TYPE The ambient temperature at or near the UPS Battery casing in 0.1 degree. | 1.3.6.1.4.1.935.10.1.1.3.8 | INTEGER | read-only | mandatory |
| upsEBatteryLastReplacedDate OBJECT-TYPE The date when the Batteries in this UPS were last replaced. The format should be DD/MM/YYYY. | 1.3.6.1.4.1.935.10.1.1.3.9 | DisplayString (SIZE(10)) | read-only | mandatory |
| upsEBatteryABMStatus OBJECT-TYPE The status of ABM. | 1.3.6.1.4.1.935.10.1.1.3.10 | INTEGER {charge(1), float(2), rest(3), discharge(4), disable(5)} | read-only | mandatory |
| upsEChargerModulesNum OBJECT-TYPE The number of charger modules inserted to UPS systems. served as the index of the upsEChargerModulesTable. The default value 0 indicate that the UPS system don't have separate charger module. | 1.3.6.1.4.1.935.10.1.1.3.11 | NonNegativeInteger (0..32) | read-only | mandatory |
| upsEChargerModulesTable OBJECT-TYPE A list of charger modules entries. The number of entries is given by the value of upsEchargerModulesNum. | 1.3.6.1.4.1.935.10.1.1.3.12 | not-accessible | mandatory | |
| upsEChargerModulesEntry OBJECT-TYPE An entry containing information applicable to a particular charger module. | 1.3.6.1.4.1.935.10.1.1.3.12.1 | not-accessible | mandatory | |
| chargerModulesNum OBJECT-TYPE The number of charger modules. Serves as index for charger module table | 1.3.6.1.4.1.935.10.1.1.3.12.1.1 | PositiveInteger (1..32) | not-accessible | mandatory |
| chargerModulesAddress OBJECT-TYPE Charger Modules' address. | 1.3.6.1.4.1.935.10.1.1.3.12.1.2 | NonNegativeInteger | read-only | mandatory |
| positiveChargeVotlage OBJECT-TYPE The measured positive charger voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.3.12.1.3 | NonNegativeInteger | read-only | mandatory |
| negativeChargeVoltage OBJECT-TYPE The measured nepositive charger voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.3.12.1.4 | NonNegativeInteger | read-only | mandatory |
| positiveChargeCurrent OBJECT-TYPE The measured positive charger mandatory from the UPS meters in in 0.1 amps. | 1.3.6.1.4.1.935.10.1.1.3.12.1.5 | NonNegativeInteger | read-only | mandatory |
| negativeChargeCurrent OBJECT-TYPE The measured nepositive charger mandatory from the UPS meters in 0.1 amps. | 1.3.6.1.4.1.935.10.1.1.3.12.1.6 | NonNegativeInteger | read-only | mandatory |
| chargerModulesTemperature OBJECT-TYPE The measured charger temperature from the UPS meters in 0.1 degree. | 1.3.6.1.4.1.935.10.1.1.3.12.1.7 | INTEGER | read-only | mandatory |
| chargerModulesMode OBJECT-TYPE The working mode of charger modules. | 1.3.6.1.4.1.935.10.1.1.3.12.1.8 | INTEGER {powerOn(1), standyby(2), fault(3), shutdown(4), running(5), suicide(6), unknown(7)} | read-only | mandatory |
| upsEPowerConverterSystem OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.4 | |||
| upsEUPSModulesNum OBJECT-TYPE The number of UPS modules inserted to UPS systems. served as the index of the upsEModulesTable. the default value 0 indicate that the UPS system do not have separate UPS module. | 1.3.6.1.4.1.935.10.1.1.4.1 | NonNegativeInteger (0..32) | read-only | mandatory |
| upsEModulesTable OBJECT-TYPE A list of UPS modules entries. The number of entries is given by the value of upsEModulesNum. | 1.3.6.1.4.1.935.10.1.1.4.2 | not-accessible | mandatory | |
| upsEModulesEntry OBJECT-TYPE An entry containing information applicable to a particular upsE module. | 1.3.6.1.4.1.935.10.1.1.4.2.1 | not-accessible | mandatory | |
| upsEModulesNum OBJECT-TYPE The number of UPS modules. Serves as index for UPS module table | 1.3.6.1.4.1.935.10.1.1.4.2.1.1 | PositiveInteger (1..32) | not-accessible | mandatory |
| upsEModuleAddress OBJECT-TYPE the address of UPS modules. | 1.3.6.1.4.1.935.10.1.1.4.2.1.2 | INTEGER | read-only | mandatory |
| upsEModulePositiveBusVolt OBJECT-TYPE The measured positive upsE module voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.4.2.1.3 | NonNegativeInteger | read-only | mandatory |
| upsEModuleNegativeBusVolt OBJECT-TYPE The measured nepositive upsE module voltage from the UPS meters in 0.1 volts | 1.3.6.1.4.1.935.10.1.1.4.2.1.4 | NonNegativeInteger | read-only | mandatory |
| upsEModuleTemperature OBJECT-TYPE The measured upsE module temperature from the UPS meters in 0.1 degree. | 1.3.6.1.4.1.935.10.1.1.4.2.1.5 | INTEGER | read-only | mandatory |
| upsEModuleWorkingMode OBJECT-TYPE The working mode of UPS modules. | 1.3.6.1.4.1.935.10.1.1.4.2.1.6 | INTEGER {power-on(1), stand-by(2), by-pass(3), line(4), battery(5), battery-test(6), fault(7), converter(8), eco(9), shutdown(10), on-booster(11), on-reducer(12), other(13)} | read-only | mandatory |
| upsEModuleOutputCurrentR OBJECT-TYPE The measured upsE module output mandatory from the UPS meters in 0.1 A. | 1.3.6.1.4.1.935.10.1.1.4.2.1.7 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputWattR OBJECT-TYPE The measured upsE module output watts from the UPS meters in watts. | 1.3.6.1.4.1.935.10.1.1.4.2.1.8 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputLoadR OBJECT-TYPE The output load of UPS modules in %. | 1.3.6.1.4.1.935.10.1.1.4.2.1.9 | INTEGER | read-only | mandatory |
| upsEModuleWarningCode OBJECT-TYPE The warning code of ups modules.Please refer the warning table of 'QU,XX' for details. | 1.3.6.1.4.1.935.10.1.1.4.2.1.10 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| upsEModuleFaultCode OBJECT-TYPE The fault code of ups modules.Please refer command 'QU,XX' for details. | 1.3.6.1.4.1.935.10.1.1.4.2.1.11 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| upsEModuleTrapState OBJECT-TYPE the values indicate the unrestored traps. For example, after AC fail, so the value of upsETrapState should be '1'. And then the AC restore, the value of upsEModuleTrapState should change to empty. | 1.3.6.1.4.1.935.10.1.1.4.2.1.12 | DisplayString (SIZE(0..127)) | read-only | mandatory |
| upsEModuleConfigOutputVA OBJECT-TYPE The magnitude of the nominal Volt-Amp rating presented in VA. | 1.3.6.1.4.1.935.10.1.1.4.2.1.13 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputCurrentS OBJECT-TYPE The measured upsE module output mandatory from the UPS meters in 0.1 A. | 1.3.6.1.4.1.935.10.1.1.4.2.1.14 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputCurrentT OBJECT-TYPE The measured upsE module output mandatory from the UPS meters in 0.1 A. | 1.3.6.1.4.1.935.10.1.1.4.2.1.15 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputWattS OBJECT-TYPE The measured upsE module output watts from the UPS meters in watts. | 1.3.6.1.4.1.935.10.1.1.4.2.1.16 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputWattT OBJECT-TYPE The measured upsE module output watts from the UPS meters in watts. | 1.3.6.1.4.1.935.10.1.1.4.2.1.17 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputLoadS OBJECT-TYPE The output load of UPS modules in %. | 1.3.6.1.4.1.935.10.1.1.4.2.1.18 | INTEGER | read-only | mandatory |
| upsEModuleOutputLoadT OBJECT-TYPE The output load of UPS modules in %. | 1.3.6.1.4.1.935.10.1.1.4.2.1.19 | INTEGER | read-only | mandatory |
| upsEModuleOutputVAR OBJECT-TYPE The magnitude of the nominal Volt-Amp rating presented in VA. | 1.3.6.1.4.1.935.10.1.1.4.2.1.20 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputVAS OBJECT-TYPE The magnitude of the nominal Volt-Amp rating presented in VA. | 1.3.6.1.4.1.935.10.1.1.4.2.1.21 | NonNegativeInteger | read-only | mandatory |
| upsEModuleOutputVAT OBJECT-TYPE The magnitude of the nominal Volt-Amp rating presented in VA. | 1.3.6.1.4.1.935.10.1.1.4.2.1.22 | NonNegativeInteger | read-only | mandatory |
| upsELoadSegment OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.5 | |||
| upsELoadSegment1OffDelay OBJECT-TYPE Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. Read this object will get countdown value of the Load Segment. | 1.3.6.1.4.1.935.10.1.1.5.1 | INTEGER | read-write | mandatory |
| upsELoadSegment1OnDelay OBJECT-TYPE Setting this object will start the Load segment output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. | 1.3.6.1.4.1.935.10.1.1.5.2 | INTEGER | read-write | mandatory |
| upsELoadSegment1AutoOffTimer OBJECT-TYPE The load segment turns automatically off after the delay while the unit operates on battery, but the shutdown is cancelled if the utility return before the delay has expired. | 1.3.6.1.4.1.935.10.1.1.5.3 | INTEGER | read-write | mandatory |
| upsELoadSegment1AutoOnTimer OBJECT-TYPE The load segment is automatically turned on after a selected delay if it has been shutdown due to on battery. | 1.3.6.1.4.1.935.10.1.1.5.4 | INTEGER | read-write | mandatory |
| upsELoadSegment1State OBJECT-TYPE Load segment output state. | 1.3.6.1.4.1.935.10.1.1.5.5 | INTEGER {off(1), on(2), off-pending(3), on-pending(4), not-support(5)} | read-only | mandatory |
| upsELoadSegment2OffDelay OBJECT-TYPE Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. Read this object will get countdown value of the Load Segment. | 1.3.6.1.4.1.935.10.1.1.5.6 | INTEGER | read-write | mandatory |
| upsELoadSegment2OnDelay OBJECT-TYPE Setting this object will start the Load segment output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. | 1.3.6.1.4.1.935.10.1.1.5.7 | INTEGER | read-write | mandatory |
| upsELoadSegment2AutoOffTimer OBJECT-TYPE The load segment turns automatically off after the delay while the unit operates on battery, but the shutdown is cancelled if the utility return before the delay has expired. | 1.3.6.1.4.1.935.10.1.1.5.8 | INTEGER | read-write | mandatory |
| upsELoadSegment2AutoOnTimer OBJECT-TYPE The load segment is automatically turned on after a selected delay if it has been shutdown due to on battery. | 1.3.6.1.4.1.935.10.1.1.5.9 | INTEGER | read-write | mandatory |
| upsELoadSegment2State OBJECT-TYPE Load segment output state. | 1.3.6.1.4.1.935.10.1.1.5.10 | INTEGER {off(1), on(2), off-pending(3), on-pending(4), not-support(5)} | read-only | mandatory |
| upsEEnvironment OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.6 | |||
| upsEEnvironmentTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.6.1 | |||
| upsEEnvironmentCurrentTemperature OBJECT-TYPE The measurement of temperature sensor, in 0.1 degree | 1.3.6.1.4.1.935.10.1.1.6.1.1 | INTEGER | read-only | mandatory |
| upsEEnvironmentTemperatureHighSetPoint OBJECT-TYPE The set point for high temperature warning, in 0.1 degrees. This value must be greater than upsEEnvironmentTemperatureLowSetPoint, and the least significant digit must be zero. | 1.3.6.1.4.1.935.10.1.1.6.1.2 | INTEGER | read-write | mandatory |
| upsEEnvironmentTemperatureHighStatus OBJECT-TYPE To enable/disable high set point check with sensor temperature. | 1.3.6.1.4.1.935.10.1.1.6.1.3 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| upsEEnvironmentTemperatureLowSetPoint OBJECT-TYPE The set point for low temperature warning, in 0.1 degrees. This value must be less than upsEEnvironmentTemperatureHighSetPoint, and the least significant digit must be zero. | 1.3.6.1.4.1.935.10.1.1.6.1.4 | INTEGER | read-write | mandatory |
| upsEEnvironmentTemperatureLowStatus OBJECT-TYPE To enable/disable low set point check with sensor temperature. | 1.3.6.1.4.1.935.10.1.1.6.1.5 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| upsEEnvironmentTemperatureOffset OBJECT-TYPE The offset to calibrate temperature of EMD, in 0.1 degrees | 1.3.6.1.4.1.935.10.1.1.6.1.6 | INTEGER | read-write | mandatory |
| upsEEnvironmentHumidity OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.6.2 | |||
| upsEEnvironmentCurrentHumidity OBJECT-TYPE The measurement of sensor humidity present in %. | 1.3.6.1.4.1.935.10.1.1.6.2.1 | INTEGER | read-only | mandatory |
| upsEEnvironmentHumidityHighSetPoint OBJECT-TYPE The set point for high humidity warning, in %. This value must be greater than upsEEnvironmentHumidityLowSetPoint. | 1.3.6.1.4.1.935.10.1.1.6.2.2 | INTEGER | read-write | mandatory |
| upsEEnvironmentHumidityHighStatus OBJECT-TYPE To enable/disable high set point check with emd humidity. | 1.3.6.1.4.1.935.10.1.1.6.2.3 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| upsEEnvironmentHumidityLowSetPoint OBJECT-TYPE The set point for low humidity warning, in %. This value must be less than upsEEnvironmentHumidityHighSetPoint. | 1.3.6.1.4.1.935.10.1.1.6.2.4 | INTEGER | read-write | mandatory |
| upsEEnvironmentHumidityLowStatus OBJECT-TYPE To enable/disable high set point check with emd humidity. | 1.3.6.1.4.1.935.10.1.1.6.2.5 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| upsEEnvironmentHumidityOffset OBJECT-TYPE The offset to calibrate humidity of EMD, in %. | 1.3.6.1.4.1.935.10.1.1.6.2.6 | INTEGER | read-write | mandatory |
| upsEEnvironmentContactsNum OBJECT-TYPE The number of environment contacts, serves as the table index. | 1.3.6.1.4.1.935.10.1.1.6.3 | NonNegativeInteger | read-only | mandatory |
| upsEEnvironmentContactTable OBJECT-TYPE A list of contacts table entries. The number of entries is given by the value of upsEEnvironmentContactsNum | 1.3.6.1.4.1.935.10.1.1.6.4 | not-accessible | mandatory | |
| upsEEnvironmentContactEntry OBJECT-TYPE An entry containing information applicable to a particular contact | 1.3.6.1.4.1.935.10.1.1.6.4.1 | not-accessible | mandatory | |
| upsEEnvironmentContactIndex OBJECT-TYPE The number of environment contacts. Serves as index for environment contact table | 1.3.6.1.4.1.935.10.1.1.6.4.1.1 | PositiveInteger | not-accessible | mandatory |
| upsEEnvironmentContactType OBJECT-TYPE operation type | 1.3.6.1.4.1.935.10.1.1.6.4.1.2 | INTEGER {normallyOpen(1), normallyClosed(2), notUsed(3)} | read-write | mandatory |
| upsEEnvironmentContactState OBJECT-TYPE The mandatory status. | 1.3.6.1.4.1.935.10.1.1.6.4.1.3 | INTEGER {open(1), closed(2), openWithNotice(3), closedWithNotice(4)} | read-only | mandatory |
| upsEEnvironmentContactDescription OBJECT-TYPE Description of environment contact. | 1.3.6.1.4.1.935.10.1.1.6.4.1.4 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| upsEBatteryTest OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.7 | |||
| upsEBatteryTestStart OBJECT-TYPE This object specify the battery test type and initiate battery test. If battTestWithTime selected, the test time is refer to upsEBatteryTestSettingTime. | 1.3.6.1.4.1.935.10.1.1.7.1 | INTEGER {none(1), batteryTest10Sec(2), batteryTestUntilLow(3), batteryTestWithTime(4), cancelBatteryTest(5), clearBatteryInfo(6)} | read-write | mandatory |
| upsEBatteryTestSettingTime OBJECT-TYPE The object specify the test time for battery test in seconds. | 1.3.6.1.4.1.935.10.1.1.7.2 | NonNegativeInteger | read-write | mandatory |
| upsEBatteryTestResult OBJECT-TYPE This object indicate the test result of battery. | 1.3.6.1.4.1.935.10.1.1.7.3 | INTEGER {idle(1), processing(2), noFailure(3), failureOrWarning(4), notPossible(5), testCancel(6)} | read-only | mandatory |
| upsEBatteryTestStartTime OBJECT-TYPE The value of the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsETestBatteryTestResult is noTestsInitiated(6), upsETestStartTime has the value 01/01/1970 00:00:00. | 1.3.6.1.4.1.935.10.1.1.7.4 | DisplayString (SIZE(19)) | read-only | mandatory |
| upsEBatteryTestElapsedTime OBJECT-TYPE The amount of time in format hh:mm:ss, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is idle(1), upsTestElapsedTime has the value 00:00:00. | 1.3.6.1.4.1.935.10.1.1.7.5 | DisplayString (SIZE(11)) | read-only | mandatory |
| upsEBatteryTestScheduleTable OBJECT-TYPE This table describes the schedule for automatically battery test. | 1.3.6.1.4.1.935.10.1.1.7.6 | not-accessible | mandatory | |
| upsEBatteryTestScheduleEntry OBJECT-TYPE An entry containing information applicable to schedule test. | 1.3.6.1.4.1.935.10.1.1.7.6.1 | not-accessible | mandatory | |
| upsEBatteryTestScheduleIndex OBJECT-TYPE The index of battery test scheduled. | 1.3.6.1.4.1.935.10.1.1.7.6.1.1 | PositiveInteger | not-accessible | mandatory |
| upsEBatteryTestScheduleDay OBJECT-TYPE The weekday or specaial day on which the UPS should start battery test. | 1.3.6.1.4.1.935.10.1.1.7.6.1.2 | INTEGER {monday(1), tuesday(2), wednsday(3), thusday(4), friday(5), saturday(6), sunday(7), specialday(8), none(9)} | read-write | mandatory |
| upsEBatteryTestScheduleTime OBJECT-TYPE The time that the battery test will be initiated in hh:mm format. | 1.3.6.1.4.1.935.10.1.1.7.6.1.3 | DisplayString (SIZE(5)) | read-write | mandatory |
| upsEBatteryTestScheduleType OBJECT-TYPE The type of battery test. | 1.3.6.1.4.1.935.10.1.1.7.6.1.5 | INTEGER {none(1), batteryTest10sec(2), batteryTestUntilLow(3), batteryTestWithTime(4)} | read-write | mandatory |
| upsEBatteryTestScheduleTestWithTime OBJECT-TYPE The battery time of setting time test in seconds. | 1.3.6.1.4.1.935.10.1.1.7.6.1.6 | NonNegativeInteger | read-write | mandatory |
| upsEBatteryTestScheduleSpecialDay OBJECT-TYPE The special day that the battery test will be initiated in dd/mm/yyyy format. | 1.3.6.1.4.1.935.10.1.1.7.6.1.7 | DisplayString (SIZE(10)) | read-write | mandatory |
| upsEControl OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.8 | |||
| upsEControlOutputOffDelay OBJECT-TYPE Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. | 1.3.6.1.4.1.935.10.1.1.8.1 | NonNegativeInteger | read-write | mandatory |
| upsEControlOutputOnDelay OBJECT-TYPE Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. | 1.3.6.1.4.1.935.10.1.1.8.2 | NonNegativeInteger | read-write | mandatory |
| upsEControlOutputOnOffControl OBJECT-TYPE upsEOutputOff ( 1 ) indicates the shutdown sequence, upsEOutputOffCancel ( 2 ) indicates cancel the shutdown sequence, upsESleep( 3 ) indicates shutdown UPS first, then switch on. | 1.3.6.1.4.1.935.10.1.1.8.3 | INTEGER {upsEOutputOff(1), upsEOutputOffCancel(2), upsESleep(3), none(4)} | read-write | mandatory |
| upsEShutdownEventsTable OBJECT-TYPE This table describes the parametes for shutdown process when shutdown event occurs | 1.3.6.1.4.1.935.10.1.1.8.4 | not-accessible | mandatory | |
| upsEShutdownEventsEntry OBJECT-TYPE An entry containing information applicable to a particular shutdown event line | 1.3.6.1.4.1.935.10.1.1.8.4.1 | not-accessible | mandatory | |
| upsEShutdownEvent OBJECT-TYPE The shutdown event identification | 1.3.6.1.4.1.935.10.1.1.8.4.1.1 | INTEGER {acFail(1), batteryLow(2), upsEOverLoad(3), upsEOverTemperature(4), upsEWeeklySchedule(5), upsESpecialSchedule(6), environmentTemperatureOverThreshold(7), environmentHumidityOverThreshold(8), environmentContact1Alarm(9), environmentContact2Alarm(10), belowCapacityLimit(11), belowRemainTimeLimit(12)} | not-accessible | mandatory |
| upsEShutdownEventAction OBJECT-TYPE Status of the corresponding shutdown Event. When set to disable(), shutdown process will not start when corresponding event occured. | 1.3.6.1.4.1.935.10.1.1.8.4.1.2 | INTEGER {disable(1), warning(2), shutdownClient(3), shutdownUPS(4)} | read-write | mandatory |
| upsEShutdownwarningPeriodTime OBJECT-TYPE The Delay in seconds after the occurance of the curresponding shutdown event, and warning message should be popped in this period. | 1.3.6.1.4.1.935.10.1.1.8.4.1.3 | NonNegativeInteger | read-write | mandatory |
| upsEShutdownWarningPeriodInterval OBJECT-TYPE The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds. | 1.3.6.1.4.1.935.10.1.1.8.4.1.4 | NonNegativeInteger | read-write | mandatory |
| upsEControlWeeklyScheduleTable OBJECT-TYPE The table to schedule shutting down the ups by weekly | 1.3.6.1.4.1.935.10.1.1.8.5 | not-accessible | mandatory | |
| upsEControlWeeklyScheduleEntry OBJECT-TYPE An entry containing information applicable to a particular line | 1.3.6.1.4.1.935.10.1.1.8.5.1 | not-accessible | mandatory | |
| upsEControlWeeklyScheduleIndex OBJECT-TYPE the index of schedule events. | 1.3.6.1.4.1.935.10.1.1.8.5.1.1 | PositiveInteger | not-accessible | mandatory |
| upsEWeeklyScheduleShutdownDay OBJECT-TYPE the weekday on which upsE shoud shutdown | 1.3.6.1.4.1.935.10.1.1.8.5.1.2 | INTEGER {monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7), none(8)} | read-write | mandatory |
| upsEWeeklyScheduleShutdownTime OBJECT-TYPE The time that the process of shutting down the UPS will be initiated in hh:mm format. | 1.3.6.1.4.1.935.10.1.1.8.5.1.3 | DisplayString (SIZE(5)) | read-write | mandatory |
| upsEWeeklyScheduleRestartDay OBJECT-TYPE the weekday on which the UPS should restart. | 1.3.6.1.4.1.935.10.1.1.8.5.1.4 | INTEGER {monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7), none(8)} | read-write | mandatory |
| upsEWeeklyScheduleRestartTime OBJECT-TYPE The time the UPS will restart in hh:mm format. | 1.3.6.1.4.1.935.10.1.1.8.5.1.5 | DisplayString (SIZE(5)) | read-write | mandatory |
| upsEControlSpecialDayScheduleTable OBJECT-TYPE The table to schedule shutting down the ups. | 1.3.6.1.4.1.935.10.1.1.8.6 | not-accessible | mandatory | |
| upsEControlSpecialDayScheduleEntry OBJECT-TYPE An entry containing information applicable to a particular line. | 1.3.6.1.4.1.935.10.1.1.8.6.1 | not-accessible | mandatory | |
| upsEControlSpecialDayScheduleIndex OBJECT-TYPE The index of special day schedule. | 1.3.6.1.4.1.935.10.1.1.8.6.1.1 | PositiveInteger | not-accessible | mandatory |
| upsESpecialDayScheduleShutdownDay OBJECT-TYPE The special day on which UPS should shutdown with the format of DD/MM/YYYY. | 1.3.6.1.4.1.935.10.1.1.8.6.1.2 | DisplayString (SIZE(10)) | read-write | mandatory |
| upsESpecialDayScheduleShutdownTime OBJECT-TYPE The time that the process of shutting down the UPS will be initiated in hh:mm format. | 1.3.6.1.4.1.935.10.1.1.8.6.1.3 | DisplayString (SIZE(5)) | read-write | mandatory |
| upsESpecialDayScheduleRestartDay OBJECT-TYPE The special day on which the UPS should restart with the format of DD/MM/YYYY. | 1.3.6.1.4.1.935.10.1.1.8.6.1.4 | DisplayString (SIZE(10)) | read-write | mandatory |
| upsESpecialDayScheduleRestartTime OBJECT-TYPE The time the UPS will restart in hh:mm format. | 1.3.6.1.4.1.935.10.1.1.8.6.1.5 | DisplayString (SIZE(5)) | read-write | mandatory |
| upsESystemMasterOffDelay OBJECT-TYPE The UPS output will shutdown after the indicated number of seconds, -1 indicate no action. | 1.3.6.1.4.1.935.10.1.1.8.7 | INTEGER | read-only | mandatory |
| upsESystemMasterOnDelay OBJECT-TYPE The UPS output will start on after the indicated number of seconds, -1 indicate no action. | 1.3.6.1.4.1.935.10.1.1.8.8 | INTEGER | read-only | mandatory |
| upsETrapControl OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.1.9 | |||
| upsETrapsReceiversTable OBJECT-TYPE This table list the managers'IP to send traps to. | 1.3.6.1.4.1.935.10.1.1.9.1 | not-accessible | mandatory | |
| upsETrapsReceiversEntry OBJECT-TYPE An entry containing information applicable to a particular input line. | 1.3.6.1.4.1.935.10.1.1.9.1.1 | not-accessible | mandatory | |
| upsETrapsReceiversIndex OBJECT-TYPE The index to a trap receiver entry | 1.3.6.1.4.1.935.10.1.1.9.1.1.1 | PositiveInteger | not-accessible | mandatory |
| upsETrapsReceiverAddress OBJECT-TYPE The IP address of the manager to send a trap to. | 1.3.6.1.4.1.935.10.1.1.9.1.1.2 | DisplayString (SIZE(0..45)) | read-write | mandatory |
| upsETrapReceiverCommunityString OBJECT-TYPE The community name to use in the trap when sent to the manager. | 1.3.6.1.4.1.935.10.1.1.9.1.1.3 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| upsETrapType OBJECT-TYPE The type of trap to be received by the manager. | 1.3.6.1.4.1.935.10.1.1.9.1.1.4 | INTEGER {none(1), rfc1628Trap(2), eppcTrap(3)} | read-write | mandatory |
| upsETrapsSeverityLevel OBJECT-TYPE The severity level of traps to be received by this manager. | 1.3.6.1.4.1.935.10.1.1.9.1.1.5 | INTEGER {informational(1), warning(2), severe(3)} | read-write | mandatory |
| upsETrapReceiverDescription OBJECT-TYPE Description of trap receivers | 1.3.6.1.4.1.935.10.1.1.9.1.1.6 | DisplayString (SIZE(0..63)) | read-write | mandatory |
| upsETrapState OBJECT-TYPE the values indicate the unrestored traps. For example, after AC fail, the agent send the trap 1(AC Fail) and trap 7(battery on) to NMS. so the value of upsETrapState should be '1,7'. And then the AC restore, the value of upsETrapState should change to empty. | 1.3.6.1.4.1.935.10.1.1.9.2 | DisplayString (SIZE(0..127)) | read-only | mandatory |
| upsETraps OBJECT-IDENTITY | 1.3.6.1.4.1.935.10.1.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| upsEPowerFail NOTIFICATION-TYPE WARNING: Utility power not available. | 1.3.6.1.4.1.935.10.1.2.0.1 | |
| upsEPowerRestored NOTIFICATION-TYPE INFORMATION: Utility power has restored. | 1.3.6.1.4.1.935.10.1.2.0.2 | |
| upsELowBattery NOTIFICATION-TYPE SEVERE: The UPS batteries are low and will soon be exhausted. | 1.3.6.1.4.1.935.10.1.2.0.3 | |
| upsEReturnFromLowBattery NOTIFICATION-TYPE INFORMATION: The UPS has return from a low battery condition. | 1.3.6.1.4.1.935.10.1.2.0.4 | |
| upsEFailed NOTIFICATION-TYPE SEVERE: The UPS is not working fine. | 1.3.6.1.4.1.935.10.1.2.0.5 | |
| upsEOk NOTIFICATION-TYPE INFORMATION: The UPS is working fine. | 1.3.6.1.4.1.935.10.1.2.0.6 | |
| upsEOnBattery NOTIFICATION-TYPE WARNING: The UPS has switched to battery backup power. | 1.3.6.1.4.1.935.10.1.2.0.7 | |
| upsENotOnBattery NOTIFICATION-TYPE INFORMATION: The UPS is not on battery power. | 1.3.6.1.4.1.935.10.1.2.0.8 | |
| upsETestInProgress NOTIFICATION-TYPE INFORMATION: The testing is going on ups. | 1.3.6.1.4.1.935.10.1.2.0.9 | |
| upsETestOver NOTIFICATION-TYPE INFORMATION: The testing of UPS is completed. | 1.3.6.1.4.1.935.10.1.2.0.10 | |
| upsEBypassOn NOTIFICATION-TYPE INFORMATION: The UPS has enabled bypass. | 1.3.6.1.4.1.935.10.1.2.0.11 | |
| upsEOnline NOTIFICATION-TYPE INFORMATION: The UPS is not on Bypass and return to normal status. | 1.3.6.1.4.1.935.10.1.2.0.12 | |
| upsECommunicationLost NOTIFICATION-TYPE SEVERE: Communication to the UPS has been lost. | 1.3.6.1.4.1.935.10.1.2.0.13 | |
| upsECommunicationEstablished NOTIFICATION-TYPE INFORMATION: Communication with the UPS has been established. | 1.3.6.1.4.1.935.10.1.2.0.14 | |
| upsEGoingShutdown NOTIFICATION-TYPE WARNING: The UPS is going to shutdown output. | 1.3.6.1.4.1.935.10.1.2.0.15 | |
| upsEShutdownCancelled NOTIFICATION-TYPE INFORMATION: The UPS is not going to shutdown output. | 1.3.6.1.4.1.935.10.1.2.0.16 | |
| upsEOutlet1GoingShutdown NOTIFICATION-TYPE WARNING: The UPS is going to shutdown outlet1. | 1.3.6.1.4.1.935.10.1.2.0.17 | |
| upsEOutlet1ShutdownCancelled NOTIFICATION-TYPE INFORMATION: The UPS is not going to shutdown outlet1. | 1.3.6.1.4.1.935.10.1.2.0.18 | |
| upsEOutlet2GoingShutdown NOTIFICATION-TYPE WARNING: The UPS is going to shutdown outlet2. | 1.3.6.1.4.1.935.10.1.2.0.19 | |
| upsEOutlet2ShutdownCancelled NOTIFICATION-TYPE INFORMATION: The UPS is not going to shutdown outlet2. | 1.3.6.1.4.1.935.10.1.2.0.20 | |
| upsESleeping NOTIFICATION-TYPE INFORMATION: UPS has entered sleep mode and power to load has been cut off. | 1.3.6.1.4.1.935.10.1.2.0.21 | |
| upsEWokeUp NOTIFICATION-TYPE INFORMATION: The UPS woke up from sleep mode and power to load has been restored. | 1.3.6.1.4.1.935.10.1.2.0.22 | |
| upsEOverTemperature NOTIFICATION-TYPE WARNING: The UPS temperature is over the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.23 | |
| upsENotOverTemperature NOTIFICATION-TYPE INFORMATION: The UPS temperature is not over the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.24 | |
| upsEOverLoad NOTIFICATION-TYPE WARNING: The UPS load is over the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.25 | |
| upsENotOverLoad NOTIFICATION-TYPE INFORMATION: The UPS load is not over the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.26 | |
| upsEModuleInserted NOTIFICATION-TYPE WARNING: UPS module or charger module plug-in. | 1.3.6.1.4.1.935.10.1.2.0.27 | |
| upsEModuleRemoved NOTIFICATION-TYPE WARNING: UPS module or charger module unplugs. | 1.3.6.1.4.1.935.10.1.2.0.28 | |
| sensorTemperatureTooHigh NOTIFICATION-TYPE WARNING: Sensor Temperature over high Set point. | 1.3.6.1.4.1.935.10.1.2.0.29 | |
| sensorTemperatureNotHigh NOTIFICATION-TYPE INFORMATION: Sensor Temperature not over high Set point. | 1.3.6.1.4.1.935.10.1.2.0.30 | |
| sensorTemperatureTooLow NOTIFICATION-TYPE WARNING: Sensor Temperature under low Set point. | 1.3.6.1.4.1.935.10.1.2.0.31 | |
| sensorTemperatureNotLow NOTIFICATION-TYPE INFORMATION: Sensor Temperature not under low Set point. | 1.3.6.1.4.1.935.10.1.2.0.32 | |
| sensorHumidityTooHigh NOTIFICATION-TYPE WARNING: Sensor Humidity over high Set point. | 1.3.6.1.4.1.935.10.1.2.0.33 | |
| sensorHumidityNotHigh NOTIFICATION-TYPE INFORMATION: Sensor Humidity not over high Set point. | 1.3.6.1.4.1.935.10.1.2.0.34 | |
| sensorHumidityTooLow NOTIFICATION-TYPE WARNING: Sensor Humidity under low Set point. | 1.3.6.1.4.1.935.10.1.2.0.35 | |
| sensorHumidityNotLow NOTIFICATION-TYPE INFORMATION: Sensor Humidity not under low Set point. | 1.3.6.1.4.1.935.10.1.2.0.36 | |
| contactAlarm1Active NOTIFICATION-TYPE WARNING: Contact Alarm-1 activated. | 1.3.6.1.4.1.935.10.1.2.0.37 | |
| concactAlarm1Normal NOTIFICATION-TYPE INFORMATION: Contact Alarm-1 not active. | 1.3.6.1.4.1.935.10.1.2.0.38 | |
| contactAlarm2Active NOTIFICATION-TYPE WARNING: Contact Alarm-2 activated. | 1.3.6.1.4.1.935.10.1.2.0.39 | |
| contactAlarm2Normal NOTIFICATION-TYPE INFORMATION: Contact Alarm-2 not active. | 1.3.6.1.4.1.935.10.1.2.0.40 | |
| upsEInternalwarning NOTIFICATION-TYPE WARNING: Internal warning. | 1.3.6.1.4.1.935.10.1.2.0.41 | |
| upsEReturnFromInternalwarning NOTIFICATION-TYPE INFORMATION: Return from Internal warning. | 1.3.6.1.4.1.935.10.1.2.0.42 | |
| upsEEPOActive NOTIFICATION-TYPE WARNING: EPO Active. | 1.3.6.1.4.1.935.10.1.2.0.43 | |
| upsEReturnFromEPOActive NOTIFICATION-TYPE INFORMATION: Return from EPO Active. | 1.3.6.1.4.1.935.10.1.2.0.44 | |
| upsEModuleUnlock NOTIFICATION-TYPE WARNING: Module Unlock. | 1.3.6.1.4.1.935.10.1.2.0.45 | |
| upsEReturnFromModuleUnlock NOTIFICATION-TYPE INFORMATION: Return from Module Unlock. | 1.3.6.1.4.1.935.10.1.2.0.46 | |
| upsEMain1Neutralloss NOTIFICATION-TYPE WARNING: Main 1 Neutral loss. | 1.3.6.1.4.1.935.10.1.2.0.47 | |
| upsEReturnFromMain1Neutralloss NOTIFICATION-TYPE INFORMATION: Return from Main 1 Neutral loss. | 1.3.6.1.4.1.935.10.1.2.0.48 | |
| upsEMain1phaseerror NOTIFICATION-TYPE WARNING: Main 1 phase error. | 1.3.6.1.4.1.935.10.1.2.0.49 | |
| upsEReturnFromMain1phaseerror NOTIFICATION-TYPE INFORMATION: Return from Main 1 phase error. | 1.3.6.1.4.1.935.10.1.2.0.50 | |
| upsESitefault NOTIFICATION-TYPE WARNING: Site fault. | 1.3.6.1.4.1.935.10.1.2.0.51 | |
| upsEReturnFromSitefault NOTIFICATION-TYPE INFORMATION: Return from Site fault. | 1.3.6.1.4.1.935.10.1.2.0.52 | |
| upsEBypassAbnormal NOTIFICATION-TYPE WARNING: Bypass Abnormal. | 1.3.6.1.4.1.935.10.1.2.0.53 | |
| upsEReturnFromBypassAbnormal NOTIFICATION-TYPE INFORMATION: Return from Bypass Abnormal. | 1.3.6.1.4.1.935.10.1.2.0.54 | |
| upsEBypassPhaseError NOTIFICATION-TYPE WARNING: Bypass Phase Error. | 1.3.6.1.4.1.935.10.1.2.0.55 | |
| upsEReturnFromBypassPhaseError NOTIFICATION-TYPE INFORMATION: Return from Bypass Phase Error. | 1.3.6.1.4.1.935.10.1.2.0.56 | |
| upsEBatteryOpen NOTIFICATION-TYPE WARNING: Battery Open. | 1.3.6.1.4.1.935.10.1.2.0.57 | |
| upsEReturnFromBatteryOpen NOTIFICATION-TYPE INFORMATION: Return from Battery Open. | 1.3.6.1.4.1.935.10.1.2.0.58 | |
| upsEBatteryOverCharge NOTIFICATION-TYPE WARNING: Battery Over Charge. | 1.3.6.1.4.1.935.10.1.2.0.59 | |
| upsEReturnFromBatteryOverCharge NOTIFICATION-TYPE INFORMATION: Return from Battery Over Charge. | 1.3.6.1.4.1.935.10.1.2.0.60 | |
| upsEBatteryReverse NOTIFICATION-TYPE WARNING: Battery Reverse. | 1.3.6.1.4.1.935.10.1.2.0.61 | |
| upsEReturnFromBatteryReverse NOTIFICATION-TYPE INFORMATION: Return from Battery Reverse. | 1.3.6.1.4.1.935.10.1.2.0.62 | |
| upsEOverloadforewarning NOTIFICATION-TYPE WARNING: Overload forewarning. | 1.3.6.1.4.1.935.10.1.2.0.63 | |
| upsEReturnFromOverloadforewarning NOTIFICATION-TYPE INFORMATION: Return from Overload forewarning. | 1.3.6.1.4.1.935.10.1.2.0.64 | |
| upsEOverloadWarning NOTIFICATION-TYPE WARNING: Overload Warning. | 1.3.6.1.4.1.935.10.1.2.0.65 | |
| upsEReturnFromOverloadWarning NOTIFICATION-TYPE INFORMATION: Return from Overload Warning. | 1.3.6.1.4.1.935.10.1.2.0.66 | |
| upsEFanLock NOTIFICATION-TYPE WARNING: Fan Lock. | 1.3.6.1.4.1.935.10.1.2.0.67 | |
| upsEReturnFromFanLock NOTIFICATION-TYPE INFORMATION: Return from Fan Lock. | 1.3.6.1.4.1.935.10.1.2.0.68 | |
| upsEMaintaincoverisopen NOTIFICATION-TYPE WARNING: Maintain cover is open. | 1.3.6.1.4.1.935.10.1.2.0.69 | |
| upsEReturnFromMaintaincoverisopen NOTIFICATION-TYPE INFORMATION: Return from Maintain cover is open. | 1.3.6.1.4.1.935.10.1.2.0.70 | |
| upsEChargerfault NOTIFICATION-TYPE WARNING: Charger fault. | 1.3.6.1.4.1.935.10.1.2.0.71 | |
| upsEReturnFromChargerfault NOTIFICATION-TYPE INFORMATION: Return from Charger fault. | 1.3.6.1.4.1.935.10.1.2.0.72 | |
| upsEModulelocationerror NOTIFICATION-TYPE WARNING: Module location error. | 1.3.6.1.4.1.935.10.1.2.0.73 | |
| upsEReturnFromModulelocationerror NOTIFICATION-TYPE INFORMATION: Return from Module location error. | 1.3.6.1.4.1.935.10.1.2.0.74 | |
| upsETurnonabnormal NOTIFICATION-TYPE WARNING: Turn on abnormal. | 1.3.6.1.4.1.935.10.1.2.0.75 | |
| upsEReturnFromTurnonabnormal NOTIFICATION-TYPE INFORMATION: Return from Turn on abnormal. | 1.3.6.1.4.1.935.10.1.2.0.76 | |
| upsERedundancyloss NOTIFICATION-TYPE WARNING: Redundancy loss. | 1.3.6.1.4.1.935.10.1.2.0.77 | |
| upsEReturnFromRedundancyloss NOTIFICATION-TYPE INFORMATION: Return from Redundancy loss. | 1.3.6.1.4.1.935.10.1.2.0.78 | |
| upsEHotSwapActived NOTIFICATION-TYPE WARNING: Hot Swap Active. | 1.3.6.1.4.1.935.10.1.2.0.79 | |
| upsEReturnFromHotSwapActived NOTIFICATION-TYPE INFORMATION: Return from Hot Swap Active. | 1.3.6.1.4.1.935.10.1.2.0.80 | |
| upsEBatteryInform NOTIFICATION-TYPE WARNING: Battery Inform. | 1.3.6.1.4.1.935.10.1.2.0.81 | |
| upsEReturnFromBatteryInform NOTIFICATION-TYPE INFORMATION: Return from Battery Inform. | 1.3.6.1.4.1.935.10.1.2.0.82 | |
| upsEInspectionInform NOTIFICATION-TYPE WARNING: Inspection Inform. | 1.3.6.1.4.1.935.10.1.2.0.83 | |
| upsEReturnFromInspectionInform NOTIFICATION-TYPE INFORMATION: Return from Inspection Inform. | 1.3.6.1.4.1.935.10.1.2.0.84 | |
| upsEGuaranteeInform NOTIFICATION-TYPE WARNING: Guarantee Inform. | 1.3.6.1.4.1.935.10.1.2.0.85 | |
| upsEReturnFromGuaranteeInform NOTIFICATION-TYPE INFORMATION: Return from Guarantee Inform. | 1.3.6.1.4.1.935.10.1.2.0.86 | |
| upsETemperatureLow NOTIFICATION-TYPE WARNING: Temperature Low. | 1.3.6.1.4.1.935.10.1.2.0.87 | |
| upsEReturnFromTemperatureLow NOTIFICATION-TYPE INFORMATION: Return from Temperature Low. | 1.3.6.1.4.1.935.10.1.2.0.88 | |
| upsETemperatureHigh NOTIFICATION-TYPE WARNING: Temperature High. | 1.3.6.1.4.1.935.10.1.2.0.89 | |
| upsEReturnFromTemperatureHigh NOTIFICATION-TYPE INFORMATION: Return from Temperature High. | 1.3.6.1.4.1.935.10.1.2.0.90 | |
| upsEBatteryOverTemperature NOTIFICATION-TYPE WARNING: Battery Over Temperature. | 1.3.6.1.4.1.935.10.1.2.0.91 | |
| upsEReturnFromBatteryOverTemperature NOTIFICATION-TYPE INFORMATION: Return from Battery Over Temperature. | 1.3.6.1.4.1.935.10.1.2.0.92 | |
| upsEFanMaintainInform NOTIFICATION-TYPE WARNING: Fan Maintain Inform. | 1.3.6.1.4.1.935.10.1.2.0.93 | |
| upsEReturnFromFanMaintainInform NOTIFICATION-TYPE INFORMATION: Return from Fan Maintain Inform. | 1.3.6.1.4.1.935.10.1.2.0.94 | |
| upsEBusCapacitanceMaintainInform NOTIFICATION-TYPE WARNING: Bus Capacitance Maintain Inform. | 1.3.6.1.4.1.935.10.1.2.0.95 | |
| upsEReturnFromBusCapacitanceMaintainInform NOTIFICATION-TYPE INFORMATION: Return from Bus Capacitance Maintain Inform. | 1.3.6.1.4.1.935.10.1.2.0.96 | |
| upsESystemOverCapacity NOTIFICATION-TYPE WARNING: System Over Capacity. | 1.3.6.1.4.1.935.10.1.2.0.97 | |
| upsEReturnFromSystemOverCapacity NOTIFICATION-TYPE INFORMATION: Return from System Over Capacity. | 1.3.6.1.4.1.935.10.1.2.0.98 | |
| upsEBelowCapacityLimit NOTIFICATION-TYPE SEVERE: The UPS batteries capacity is lower than setting limit. | 1.3.6.1.4.1.935.10.1.2.0.123 | |
| upsENotBelowCapacityLimit NOTIFICATION-TYPE INFORMATION: The UPS batteries capacity is not lower than setting limit. | 1.3.6.1.4.1.935.10.1.2.0.124 | |
| upsEBelowRemainTimeLimit NOTIFICATION-TYPE SEVERE: The UPS batteries backup time is below the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.125 | |
| upsENotBelowRemainTimeLimit NOTIFICATION-TYPE INFORMATION: The UPS batteries backup time is not below the setting limit. | 1.3.6.1.4.1.935.10.1.2.0.126 | |
| upsELoadSegment1Off NOTIFICATION-TYPE WARNING: Load segment 1 is off. | 1.3.6.1.4.1.935.10.1.2.0.127 | |
| upsELoadSegment1On NOTIFICATION-TYPE INFORMATION: Load segment 1 is on. | 1.3.6.1.4.1.935.10.1.2.0.128 | |
| upsELoadSegment2Off NOTIFICATION-TYPE WARNING: Load segment 2 is off. | 1.3.6.1.4.1.935.10.1.2.0.129 | |
| upsELoadSegment2On NOTIFICATION-TYPE INFORMATION: Load segment 2 is on. | 1.3.6.1.4.1.935.10.1.2.0.130 |