XPPC-MIB
- Registered at
- 1.3.6.1.4.1.935.11.3.6.1.4.1.935.2
- Namespace
- logmaster
- Source file
XPPC-MIB- Digest
sha256:63865bfa1f6cc6155562a6efde699598722136220e944d81887d3abde73fc757
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC XPPC-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ppc OBJECT-IDENTITY | 1.3.6.1.4.1.935 | |||
| products OBJECT-IDENTITY | 1.3.6.1.4.1.935.1 | |||
| hardware OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1 | |||
| ups OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1 | |||
| upsIdentp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.1 | |||
| upsBaseIdent OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.1.1 | |||
| upsBaseIdentModel OBJECT-TYPE The UPS model name (e.g. 'Intelligent 8000E 900VA'). | 1.3.6.1.4.1.935.1.1.1.1.1.1 | DisplayString | read-only | mandatory |
| upsBaseIdentUpsName OBJECT-TYPE An 8 byte ID string identifying the UPS. This object can be set by the administrator. | 1.3.6.1.4.1.935.1.1.1.1.1.2 | DisplayString | read-write | mandatory |
| upsSmartIdent OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.1.2 | |||
| upsSmartIdentFirmwareRevision OBJECT-TYPE The firmware revision of the UPS system. | 1.3.6.1.4.1.935.1.1.1.1.2.1 | DisplayString | read-only | mandatory |
| upsSmartIdentDateOfManufacture OBJECT-TYPE The date when the UPS was manufactured in mm/dd/yy format. | 1.3.6.1.4.1.935.1.1.1.1.2.2 | DisplayString | read-only | mandatory |
| upsSmartIdentUpsSerialNumber OBJECT-TYPE An 8-character string identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspond to the serial number on the rear of the UPS. | 1.3.6.1.4.1.935.1.1.1.1.2.3 | DisplayString | read-only | mandatory |
| upsSmartIdentAgentFirmwareRevision OBJECT-TYPE The firmware revision of the UPS SNMP Proxy agent. | 1.3.6.1.4.1.935.1.1.1.1.2.4 | DisplayString | read-only | mandatory |
| upsBatteryp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.2 | |||
| upsBaseBattery OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.2.1 | |||
| upsBaseBatteryStatus OBJECT-TYPE The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsSmartConfigLowBatteryRunTime. | 1.3.6.1.4.1.935.1.1.1.2.1.1 | INTEGER {unknown(1), batteryNormal(2), batteryLow(3)} | read-only | mandatory |
| upsBaseBatteryTimeOnBattery OBJECT-TYPE The elapsed time in seconds since the UPS has switched to battery power. | 1.3.6.1.4.1.935.1.1.1.2.1.2 | INTEGER | read-only | mandatory |
| upsBaseBatteryLastReplaceDate OBJECT-TYPE The date when the UPS system's batteries were last replaced in mm/dd/yy format. For UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator. | 1.3.6.1.4.1.935.1.1.1.2.1.3 | DisplayString | read-write | mandatory |
| upsSmartBattery OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.2.2 | |||
| upsSmartBatteryCapacity OBJECT-TYPE The remaining battery capacity expressed in percent of full capacity. | 1.3.6.1.4.1.935.1.1.1.2.2.1 | INTEGER | read-only | mandatory |
| upsSmartBatteryVoltage OBJECT-TYPE The current battery voltage expressed in 1/10 VDC. | 1.3.6.1.4.1.935.1.1.1.2.2.2 | INTEGER | read-only | mandatory |
| upsSmartBatteryTemperature OBJECT-TYPE The current internal UPS temperature expressed in tenths of a Celsius degree. | 1.3.6.1.4.1.935.1.1.1.2.2.3 | INTEGER | read-only | mandatory |
| upsSmartBatteryRunTimeRemaining OBJECT-TYPE The UPS battery run time remaining before battery exhaustion, in seconds. | 1.3.6.1.4.1.935.1.1.1.2.2.4 | INTEGER | read-only | mandatory |
| upsSmartBatteryReplaceIndicator OBJECT-TYPE Indicates whether the UPS batteries need replacing. | 1.3.6.1.4.1.935.1.1.1.2.2.5 | INTEGER {noBatteryNeedsReplacing(1), batteryNeedsReplacing(2)} | read-only | mandatory |
| upsSmartBatteryFullChargeVoltage OBJECT-TYPE The fully charged battery voltage of the battery system used in the UPS, expressed in tenths of a volt. | 1.3.6.1.4.1.935.1.1.1.2.2.6 | INTEGER | read-only | mandatory |
| upsSmartBatteryCurrent OBJECT-TYPE The current battery current expressed in percent of maximum current. | 1.3.6.1.4.1.935.1.1.1.2.2.7 | INTEGER | read-only | mandatory |
| upsInputp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.3 | |||
| upsBaseInput OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.3.1 | |||
| upsBaseInputPhase OBJECT-TYPE The current AC input phase. | 1.3.6.1.4.1.935.1.1.1.3.1.1 | INTEGER | read-only | mandatory |
| upsSmartInput OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.3.2 | |||
| upsSmartInputLineVoltage OBJECT-TYPE The current utility line voltage in 1/10 VAC. | 1.3.6.1.4.1.935.1.1.1.3.2.1 | INTEGER | read-only | mandatory |
| upsSmartInputMaxLineVoltage OBJECT-TYPE The maximum utility line voltage in 1/10 VAC over the previous 1 minute period. | 1.3.6.1.4.1.935.1.1.1.3.2.2 | INTEGER | read-only | mandatory |
| upsSmartInputMinLineVoltage OBJECT-TYPE The minimum utility line voltage in 1/10 VAC over the previous 1 minute period. | 1.3.6.1.4.1.935.1.1.1.3.2.3 | INTEGER | read-only | mandatory |
| upsSmartInputFrequency OBJECT-TYPE The current input frequency to the UPS system in 1/10 Hz. | 1.3.6.1.4.1.935.1.1.1.3.2.4 | INTEGER | read-only | mandatory |
| upsSmartInputLineFailCause OBJECT-TYPE The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. | 1.3.6.1.4.1.935.1.1.1.3.2.5 | INTEGER {noTransfer(1), highLineVoltage(2), brownout(3), blackout(4), smallMomentarySag(5), deepMomentarySag(6), smallMomentarySpike(7), largeMomentarySpike(8)} | read-only | mandatory |
| upsOutputp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.4 | |||
| upsBaseOutput OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.4.1 | |||
| upsBaseOutputStatus OBJECT-TYPE The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1). | 1.3.6.1.4.1.935.1.1.1.4.1.1 | INTEGER {unknown(1), onLine(2), onBattery(3), onBoost(4), sleeping(5), onBypass(6), rebooting(7), standBy(8), onBuck(9)} | read-only | mandatory |
| upsBaseOutputPhase OBJECT-TYPE The current output phase. | 1.3.6.1.4.1.935.1.1.1.4.1.2 | INTEGER | read-only | mandatory |
| upsSmartOutput OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.4.2 | |||
| upsSmartOutputVoltage OBJECT-TYPE The output voltage of the UPS system in 1/10 VAC. | 1.3.6.1.4.1.935.1.1.1.4.2.1 | INTEGER | read-only | mandatory |
| upsSmartOutputFrequency OBJECT-TYPE The current output frequency of the UPS system in 1/10 Hz. | 1.3.6.1.4.1.935.1.1.1.4.2.2 | INTEGER | read-only | mandatory |
| upsSmartOutputLoad OBJECT-TYPE The current UPS load expressed in percent of rated capacity. | 1.3.6.1.4.1.935.1.1.1.4.2.3 | INTEGER | read-only | mandatory |
| upsConfigp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.5 | |||
| upsBaseConfig OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.5.1 | |||
| upsBaseConfigNumDevices OBJECT-TYPE The number of devices that are plugged into the UPS. | 1.3.6.1.4.1.935.1.1.1.5.1.1 | INTEGER | read-only | mandatory |
| upsBaseConfigDeviceTable OBJECT-TYPE A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBaseConfigNumDevices. | 1.3.6.1.4.1.935.1.1.1.5.1.2 | not-accessible | mandatory | |
| upsBaseConfigDeviceEntry OBJECT-TYPE The devices plugged in to the UPS. | 1.3.6.1.4.1.935.1.1.1.5.1.2.1 | not-accessible | mandatory | |
| indexOfDevice OBJECT-TYPE The index of the device that is plugged into the UPS. | 1.3.6.1.4.1.935.1.1.1.5.1.2.1.1 | INTEGER | read-only | mandatory |
| nameOfDevice OBJECT-TYPE The name/description of the device plugged into the UPS. | 1.3.6.1.4.1.935.1.1.1.5.1.2.1.2 | DisplayString | read-write | mandatory |
| vaRatingOfDevice OBJECT-TYPE The volt-amp rating of the device plugged into the UPS. | 1.3.6.1.4.1.935.1.1.1.5.1.2.1.3 | INTEGER | read-write | mandatory |
| deviceAccept OBJECT-TYPE An entry is added if yes, the entry is deleted if no. | 1.3.6.1.4.1.935.1.1.1.5.1.2.1.4 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| upsSmartConfig OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.5.2 | |||
| upsSmartConfigRatedOutputVoltage OBJECT-TYPE The nominal output voltage from the UPS in 1/10 VAC. Possible values are 1000, 1200, 2080, 2200, 2250, 2300 and 2400. NOTE: Only units that are 2200, 2250, 2300 and 2400 can be changed. Allowable values are 2200, 2250, 2300 and 2400. For these adjustable units, if a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.1 | INTEGER | read-write | mandatory |
| upsSmartConfigHighTransferVolt OBJECT-TYPE The maximum line voltage in 1/10 VAC allowed before the UPS system transfers to battery backup. Allowed value depend on the UPS used: 120 Volt units allow settings of 1290, 1320, 1350, 1380. 100 Volt units allow settings of 1080, 1100, 1120, 1140. 230 Volt units allow settings of 2530, 2640, 2710, 2800. 208 Volt units allow settings of 2240, 2290, 2340, 2390. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.2 | INTEGER | read-write | mandatory |
| upsSmartConfigLowTransferVolt OBJECT-TYPE The minimum line voltage in 1/10 VAC allowed before the UPS system transfers to battery backup. Allowable values depend on the UPS used: 120 Volt units allow settings of 970, 1000, 1030, 1060. 100 Volt units allow settings of 810, 830, 850, 870. 230 Volt units allow settings of 1880, 1960, 2040, 2080. 208 Volt units allow settings of 1680, 1720, 1770, 1820. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.3 | INTEGER | read-write | mandatory |
| upsSmartConfigAlarm OBJECT-TYPE A flag indicating how the UPS should handle audible line fail alarms. | 1.3.6.1.4.1.935.1.1.1.5.2.4 | INTEGER {timed(1), atLowBattery(2), never(3)} | read-write | mandatory |
| upsSmartConfigAlarmTimer OBJECT-TYPE The time in seconds after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observerd only if the value of extControlAlarm is timed(2). Allowed values are 0 or 30 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.5 | INTEGER | read-write | mandatory |
| upsSmartConfigMinReturnCapacity OBJECT-TYPE The minimum battery capacity as a percent of full capacity required before the UPS will return from a low battery shutdown condition. In other words, the UPS will not re-energize the output until the battery capacity is equal to this value. Allowed values are 0, 10, 25, or 90 percent. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.6 | INTEGER | read-write | mandatory |
| upsSmartConfigSensitivity OBJECT-TYPE The sensitivity of the UPS to utility line abnormalities or noises. | 1.3.6.1.4.1.935.1.1.1.5.2.7 | INTEGER {auto(1), low(2), medium(3), high(4)} | read-write | mandatory |
| upsSmartConfigLowBatteryRunTime OBJECT-TYPE The desired run time in seconds once the low battery condition is reached. Allowed values are 120, 300, 420, or 600 seconds. During this time the UPS will produce a constant warning tone which can not be disabled. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.8 | INTEGER | read-write | mandatory |
| upsSmartConfigReturnDelay OBJECT-TYPE The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UPS wakes up from 'sleep' mode. Allowed values are 0, 60, 180 and 300 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.9 | INTEGER | read-write | mandatory |
| upsSmartConfigShutoffDelay OBJECT-TYPE The delay in seconds the UPS remains on after being told to turn off. Allowed values are 12, 18, 24, 30, 36, 42, 48, 54, 60, 120, 180, 240, 300, 360, 420, 480, 540, and 600 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.10 | INTEGER | read-write | mandatory |
| upsSmartConfigUpsSleepTime OBJECT-TYPE The time in minutes for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 0 - 9999 minutes in one minute increments. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.935.1.1.1.5.2.11 | INTEGER | read-write | mandatory |
| upsSmartConfigSetEEPROMDefaults OBJECT-TYPE WRITE: Resets the UPS EEPROM variables to default values. READ: returns 0 | 1.3.6.1.4.1.935.1.1.1.5.2.12 | INTEGER {noSetEEPROMDefaults(1), setEEPROMDefaults(2)} | read-write | mandatory |
| upsControlp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.6 | |||
| upsBaseControl OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.6.1 | |||
| upsBaseControlConserveBattery OBJECT-TYPE Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode immediately. The (10) means suspending time(10 minutes) before turn off UPS. UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.1.1 | INTEGER {noTurnOffUps(1), turnUpsOffToConserveBattery(2), turnUpsOffToConserveBatteryDelay(3)} | read-write | mandatory |
| upsSmartControl OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.6.2 | |||
| upsSmartControlUpsOff OBJECT-TYPE Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state. The on/off switch on the UPS must be toggled for the UPS to return to operation. Setting this value to noTurnUpsOff(1) has no effect. The value noTurnUpsOff(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.1 | INTEGER {noTurnUpsOff(1), turnUpsOff(2)} | read-write | mandatory |
| upsSmartControlRebootUps OBJECT-TYPE Setting this variable to rebootUps(2) causes the UPS to shut off and turn back on. Setting this value to noRebootUps(1) has no effect. The value noRebootUps(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.2 | INTEGER {noRebootUps(1), rebootUps(2)} | read-write | mandatory |
| upsSmartControlUpsSleep OBJECT-TYPE Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsSmartConfigUpsSleepTime. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. Setting this value to noPutUpsToSleep(1) has no effect. The value noPutUpsToSleep(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.3 | INTEGER {noPutUpsToSleep(1), putUpsToSleep(2)} | read-write | mandatory |
| upsSmartControlSimulatePowerFail OBJECT-TYPE Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The value noSimulatePowerFailure(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.4 | INTEGER {noSimulatePowerFailure(1), simulatePowerFailure(2)} | read-write | mandatory |
| upsSmartControlFlashAndBeep OBJECT-TYPE UPS to identify itself by lighting all indicators and beeping. Setting this variable to FlashAndBeep(2) causes the UPS lights all panel indicators and beeps. Setting this value to noFlashAndBeep(1) has no effect. The value noFlashAndBeep(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.5 | INTEGER {noFlashAndBeep(1), flashAndBeep(2)} | read-write | mandatory |
| upsSmartControlTurnOnUpsLoad OBJECT-TYPE Setting this variable to upsSmartControlTurnOnUpsLoad(2) causes the UPS switch back to utility power if utility power is present. Setting this value to noUpsSmartControlTurnOnUpsLoad(1) has no effect. The value noUpsSmartControlTurnOnUpsLoad(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.6.2.6 | INTEGER {noUpsSmartControlTurnOnUpsLoad(1), upsSmartControlTurnOnUpsLoad(2)} | read-write | mandatory |
| upsTestp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.7 | |||
| upsBaseTest OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.7.1 | |||
| upsSmartTest OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.7.2 | |||
| upsSmartTestDiagnosticSchedule OBJECT-TYPE The UPS system's automatic battery test schedule. | 1.3.6.1.4.1.935.1.1.1.7.2.1 | INTEGER {unknown(1), biweekly(2), weekly(3), never(4)} | read-write | mandatory |
| upsSmartTestDiagnostics OBJECT-TYPE Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The value noTestDiagnostics(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.7.2.2 | INTEGER {noTestDiagnostics(1), testDiagnostics(2)} | read-write | mandatory |
| upsSmartTestDiagnosticsResults OBJECT-TYPE The results of the last UPS diagnostics test performed. | 1.3.6.1.4.1.935.1.1.1.7.2.3 | INTEGER {ok(1), failed(2), invalidTest(3), testInProgress(4)} | read-only | mandatory |
| upsSmartTestLastDiagnosticsDate OBJECT-TYPE The date the last UPS diagnostics test was performed in mm/dd/yy format. | 1.3.6.1.4.1.935.1.1.1.7.2.4 | DisplayString | read-only | mandatory |
| upsSmartTestIndicators OBJECT-TYPE Setting this variable to testIndicators(2) causes the UPS to perform a front panel indicator (lights) test. Setting this value to noTestIndicators(1) has no effect. The value noTestIndicators(1) will always be returned when the variable is read. | 1.3.6.1.4.1.935.1.1.1.7.2.5 | INTEGER {noTestIndicators(1), testIndicators(2)} | read-write | mandatory |
| upsSmartTestRuntimeCalibration OBJECT-TYPE Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult. | 1.3.6.1.4.1.935.1.1.1.7.2.6 | INTEGER {noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3)} | read-write | mandatory |
| upsSmartTestCalibrationResults OBJECT-TYPE The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidTest(2) indicates last calibration did not take place since the battery capacity was below 100 percent. Value calibrationInProgress(3) means a calibration is occurring now. | 1.3.6.1.4.1.935.1.1.1.7.2.7 | INTEGER {ok(1), invalidTest(2), calibrationInProgress(3)} | read-only | mandatory |
| upsSmartTestCalibrationDate OBJECT-TYPE The date the last UPS runtime calibration was performed in mm/dd/yy format. | 1.3.6.1.4.1.935.1.1.1.7.2.8 | DisplayString | read-only | mandatory |
| upsThreePhase OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8 | |||
| upsThreePhaseBatteryGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.1 | |||
| upsThreePhaseBatteryVoltage OBJECT-TYPE Battery Voltage | 1.3.6.1.4.1.935.1.1.1.8.1.1 | INTEGER | read-only | mandatory |
| upsThreePhaseBatteryCapacityPercentage OBJECT-TYPE Battery Capacity Percentage | 1.3.6.1.4.1.935.1.1.1.8.1.2 | INTEGER | read-only | mandatory |
| upsThreePhaseBatteryTimeRemain OBJECT-TYPE Battery Time Remain (unit is Minute) | 1.3.6.1.4.1.935.1.1.1.8.1.3 | INTEGER | read-only | mandatory |
| upsThreePhaseBatteryCurrent OBJECT-TYPE Battery Electric Current | 1.3.6.1.4.1.935.1.1.1.8.1.4 | INTEGER | read-only | mandatory |
| upsThreePhaseBatteryTemperature OBJECT-TYPE Battery Temperature | 1.3.6.1.4.1.935.1.1.1.8.1.5 | INTEGER | read-only | mandatory |
| upsThreePhaseInputGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.2 | |||
| upsThreePhaseInputFrequency OBJECT-TYPE Input Frequency | 1.3.6.1.4.1.935.1.1.1.8.2.1 | INTEGER | read-only | mandatory |
| upsThreePhaseInputVoltageR OBJECT-TYPE Input VoltageR | 1.3.6.1.4.1.935.1.1.1.8.2.2 | INTEGER | read-only | mandatory |
| upsThreePhaseInputVoltageS OBJECT-TYPE Input VoltageS | 1.3.6.1.4.1.935.1.1.1.8.2.3 | INTEGER | read-only | mandatory |
| upsThreePhaseInputVoltageT OBJECT-TYPE Input VoltageT | 1.3.6.1.4.1.935.1.1.1.8.2.4 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.3 | |||
| upsThreePhaseOutputFrequency OBJECT-TYPE Output Frequency | 1.3.6.1.4.1.935.1.1.1.8.3.1 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputVoltageR OBJECT-TYPE Output VoltageR | 1.3.6.1.4.1.935.1.1.1.8.3.2 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputVoltageS OBJECT-TYPE Output VoltageS | 1.3.6.1.4.1.935.1.1.1.8.3.3 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputVoltageT OBJECT-TYPE Output VoltageT | 1.3.6.1.4.1.935.1.1.1.8.3.4 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputLoadPercentageR OBJECT-TYPE Load PercentageR | 1.3.6.1.4.1.935.1.1.1.8.3.5 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputLoadPercentageS OBJECT-TYPE Load PercentageS | 1.3.6.1.4.1.935.1.1.1.8.3.6 | INTEGER | read-only | mandatory |
| upsThreePhaseOutputLoadPercentageT OBJECT-TYPE Load PercentageT | 1.3.6.1.4.1.935.1.1.1.8.3.7 | INTEGER | read-only | mandatory |
| upsThreePhaseBypassGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.4 | |||
| upsThreePhaseBypassSourceFrequency OBJECT-TYPE Bypass Frequency | 1.3.6.1.4.1.935.1.1.1.8.4.1 | INTEGER | read-only | mandatory |
| upsThreePhaseBypssSourceVoltageR OBJECT-TYPE Bypass VoltageR | 1.3.6.1.4.1.935.1.1.1.8.4.2 | INTEGER | read-only | mandatory |
| upsThreePhaseBypssSourceVoltageS OBJECT-TYPE Bypass VoltageS | 1.3.6.1.4.1.935.1.1.1.8.4.3 | INTEGER | read-only | mandatory |
| upsThreePhaseBypssSourceVoltageT OBJECT-TYPE Bypass VoltageT | 1.3.6.1.4.1.935.1.1.1.8.4.4 | INTEGER | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.5 | |||
| upsThreePhaseDCandRectifierStatusRecRotError OBJECT-TYPE Rectifier Rotation Error | 1.3.6.1.4.1.935.1.1.1.8.5.1 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusLowBatteryShutdown OBJECT-TYPE Low Battery Shutdown | 1.3.6.1.4.1.935.1.1.1.8.5.2 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusLowBattery OBJECT-TYPE Low Battery | 1.3.6.1.4.1.935.1.1.1.8.5.3 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusInAndOut OBJECT-TYPE In And Put | 1.3.6.1.4.1.935.1.1.1.8.5.4 | INTEGER {threeInOneOut(2), threeInThreeOut(3)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusBatteryStatus OBJECT-TYPE Back Status | 1.3.6.1.4.1.935.1.1.1.8.5.5 | INTEGER {backup(4), acnormal(5)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusChargeStatus OBJECT-TYPE Charge Status | 1.3.6.1.4.1.935.1.1.1.8.5.6 | INTEGER {boost(6), float(7), no(16)} | read-only | mandatory |
| upsThreePhaseDCandRectifierStatusRecOperating OBJECT-TYPE Rectifier Operating | 1.3.6.1.4.1.935.1.1.1.8.5.7 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseUPSStatusGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.6 | |||
| upsThreePhaseUPSStatusBypassFreqFail OBJECT-TYPE Bypass Status | 1.3.6.1.4.1.935.1.1.1.8.6.1 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseUPSStatusManualBypassBreaker OBJECT-TYPE Breaker Status | 1.3.6.1.4.1.935.1.1.1.8.6.2 | INTEGER {close(8), open(9)} | read-only | mandatory |
| upsThreePhaseUPSStatusACStatus OBJECT-TYPE AC Status | 1.3.6.1.4.1.935.1.1.1.8.6.3 | INTEGER {normal(10), abnormal(11)} | read-only | mandatory |
| upsThreePhaseUPSStaticSwitchMode OBJECT-TYPE Switch Mode | 1.3.6.1.4.1.935.1.1.1.8.6.4 | INTEGER {invermode(12), bypassmode(13)} | read-only | mandatory |
| upsThreePhaseUPSStatusInverterOperating OBJECT-TYPE Operating | 1.3.6.1.4.1.935.1.1.1.8.6.5 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.7 | |||
| upsThreePhaseFaultStatusEmergencyStop OBJECT-TYPE Emergency Stop | 1.3.6.1.4.1.935.1.1.1.8.7.1 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusHighDCShutdown OBJECT-TYPE High DC Shutdown | 1.3.6.1.4.1.935.1.1.1.8.7.2 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusBypassBreaker OBJECT-TYPE Bypass Breaker | 1.3.6.1.4.1.935.1.1.1.8.7.3 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusOverLoad OBJECT-TYPE Over Load | 1.3.6.1.4.1.935.1.1.1.8.7.4 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusInverterOutputFail OBJECT-TYPE Output Fail | 1.3.6.1.4.1.935.1.1.1.8.7.5 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusOverTemperature OBJECT-TYPE Over Temperature | 1.3.6.1.4.1.935.1.1.1.8.7.6 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseFaultStatusShortCircuit OBJECT-TYPE Short Circuit | 1.3.6.1.4.1.935.1.1.1.8.7.7 | INTEGER {yes(14), no(16)} | read-only | mandatory |
| upsThreePhaseRatingGrp OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.8.8 | |||
| upsThreePhaseRatingRectifierVoltage OBJECT-TYPE Rectifier Voltage | 1.3.6.1.4.1.935.1.1.1.8.8.1 | DisplayString | read-only | mandatory |
| upsThreePhaseRatingRectifierFrequency OBJECT-TYPE Rectifier Frequency | 1.3.6.1.4.1.935.1.1.1.8.8.2 | INTEGER | read-only | mandatory |
| upsThreePhaseRatingBypassVoltage OBJECT-TYPE Bypass Voltage | 1.3.6.1.4.1.935.1.1.1.8.8.3 | DisplayString | read-only | mandatory |
| upsThreePhaseRatingBypassFrequency OBJECT-TYPE Bypass Frequency | 1.3.6.1.4.1.935.1.1.1.8.8.4 | INTEGER | read-only | mandatory |
| upsThreePhaseRatingOutputVoltage OBJECT-TYPE Output Voltage | 1.3.6.1.4.1.935.1.1.1.8.8.5 | DisplayString | read-only | mandatory |
| upsThreePhaseRatingOutputFrequency OBJECT-TYPE Output Frequency | 1.3.6.1.4.1.935.1.1.1.8.8.6 | INTEGER | read-only | mandatory |
| upsThreePhaseRatingBatteryVoltage OBJECT-TYPE Battery Voltage | 1.3.6.1.4.1.935.1.1.1.8.8.7 | INTEGER | read-only | mandatory |
| upsThreePhaseRatingPower OBJECT-TYPE Power Rating | 1.3.6.1.4.1.935.1.1.1.8.8.8 | DisplayString | read-only | mandatory |
| upsEnvironment OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.9 | |||
| upsEnvStatus OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.9.1 | |||
| upsEnvTemperature OBJECT-TYPE The ambient environment temperature. | 1.3.6.1.4.1.935.1.1.1.9.1.1 | INTEGER | read-only | mandatory |
| upsEnvHumidity OBJECT-TYPE The environment humidity. | 1.3.6.1.4.1.935.1.1.1.9.1.2 | INTEGER | read-only | mandatory |
| upsEnvWater OBJECT-TYPE Water status | 1.3.6.1.4.1.935.1.1.1.9.1.3 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSmoke OBJECT-TYPE Smoke status | 1.3.6.1.4.1.935.1.1.1.9.1.4 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity1 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.5 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity2 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.6 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity3 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.7 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity4 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.8 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity5 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.9 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity6 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.10 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSecurity7 OBJECT-TYPE Security status | 1.3.6.1.4.1.935.1.1.1.9.1.11 | INTEGER {normal(1), abnormal(2)} | read-only | mandatory |
| upsEnvSetting OBJECT-IDENTITY | 1.3.6.1.4.1.935.1.1.1.9.2 | |||
| upsEnvOverTemperature OBJECT-TYPE Alarm dupsAlarmOverTemperature on when the environment temperature over the value. | 1.3.6.1.4.1.935.1.1.1.9.2.1 | INTEGER | read-write | mandatory |
| upsEnvUnderTemperature OBJECT-TYPE Alarm dupsAlarmUnderTemperature on when the environment temperature below the value. | 1.3.6.1.4.1.935.1.1.1.9.2.2 | INTEGER | read-write | mandatory |
| upsEnvOverHumidity OBJECT-TYPE Alarm dupsAlarmOverHumidity on when the environment humidity over the value. | 1.3.6.1.4.1.935.1.1.1.9.2.3 | INTEGER | read-write | mandatory |
| upsEnvUnderHumidity OBJECT-TYPE Alarm dupsAlarmUnderHumidity on when the environment humidity below the value. | 1.3.6.1.4.1.935.1.1.1.9.2.4 | INTEGER | read-write | mandatory |
| ppcmgmt OBJECT-IDENTITY | 1.3.6.1.4.1.935.2 | |||
| mconfig OBJECT-IDENTITY | 1.3.6.1.4.1.935.2.1 | |||
| mconfigTrapsReceiversNum OBJECT-TYPE The number of managers to send traps to. | 1.3.6.1.4.1.935.2.1.1 | INTEGER | read-only | mandatory |
| mconfigTrapsReceiversTable OBJECT-TYPE A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers | 1.3.6.1.4.1.935.2.1.2 | not-accessible | mandatory | |
| mconfigTrapsReceiversEntry OBJECT-TYPE The managers to send traps to. | 1.3.6.1.4.1.935.2.1.2.1 | not-accessible | mandatory | |
| trapsIndex OBJECT-TYPE The index to a trap receiver entry. | 1.3.6.1.4.1.935.2.1.2.1.1 | INTEGER | read-only | mandatory |
| trapsReceiverAddr OBJECT-TYPE The IP address of the manager to send a trap to. | 1.3.6.1.4.1.935.2.1.2.1.2 | IpAddress | read-write | mandatory |
| receiverCommunityString OBJECT-TYPE The community name to use in the trap when sent to the manager. | 1.3.6.1.4.1.935.2.1.2.1.3 | DisplayString | read-write | mandatory |
| severityLevel OBJECT-TYPE The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. | 1.3.6.1.4.1.935.2.1.2.1.4 | INTEGER {information(1), warning(2), severe(3)} | read-write | mandatory |
| receiverAccept OBJECT-TYPE An entry will become active if yes, and will be deleted if no. | 1.3.6.1.4.1.935.2.1.2.1.5 | INTEGER {yes(1), no(2)} | read-write | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| communicationLost NOTIFICATION-TYPE SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress. | 1.3.6.1.4.1.935.0.1 | |
| upsOverLoad NOTIFICATION-TYPE SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity. | 1.3.6.1.4.1.935.0.2 | |
| upsDiagnosticsFailed NOTIFICATION-TYPE SEVERE: The UPS failed its internal diagnostic self-test. | 1.3.6.1.4.1.935.0.3 | |
| upsDischarged NOTIFICATION-TYPE SEVERE: The UPS just started a runtime calibration discharge. The UPS batteries are being discharged. | 1.3.6.1.4.1.935.0.4 | |
| upsOnBattery NOTIFICATION-TYPE WARNING: The UPS has switched to battery backup power. | 1.3.6.1.4.1.935.0.5 | |
| boostOn NOTIFICATION-TYPE WARNING: The UPS has enabled Boost. | 1.3.6.1.4.1.935.0.6 | |
| lowBattery NOTIFICATION-TYPE SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load. | 1.3.6.1.4.1.935.0.7 | |
| communicationEstablished NOTIFICATION-TYPE INFORMATION: Communication with the UPS has been established. | 1.3.6.1.4.1.935.0.8 | |
| powerRestored NOTIFICATION-TYPE INFORMATION: Utility power has been restored. | 1.3.6.1.4.1.935.0.9 | |
| upsDiagnosticsPassed NOTIFICATION-TYPE INFORMATION: The UPS passed its internal self-test. | 1.3.6.1.4.1.935.0.10 | |
| returnFromLowBattery NOTIFICATION-TYPE INFORMATION: The UPS has returned from a low battery condition. | 1.3.6.1.4.1.935.0.11 | |
| upsTurnedOff NOTIFICATION-TYPE WARNING: The UPS has been turned 'off' by the management station. | 1.3.6.1.4.1.935.0.12 | |
| upsSleeping NOTIFICATION-TYPE WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off. | 1.3.6.1.4.1.935.0.13 | |
| upsWokeUp NOTIFICATION-TYPE INFORMATION: The UPS woke up from 'sleep' mode. Power to the load has been restored. | 1.3.6.1.4.1.935.0.14 | |
| upsRebootStarted NOTIFICATION-TYPE WARNING: The UPS has started its reboot sequence. After the specified delay the UPS will perform a reboot. | 1.3.6.1.4.1.935.0.15 | |
| envOverTemperature NOTIFICATION-TYPE WARNING: The environment temperature exceed the normal value. | 1.3.6.1.4.1.935.0.16 | |
| envTemperatureNormal NOTIFICATION-TYPE INFORMATION: The environment temperature is normal. | 1.3.6.1.4.1.935.0.17 | |
| envOverHumidity NOTIFICATION-TYPE WARNING: The environment humidity exceed the normal value. | 1.3.6.1.4.1.935.0.18 | |
| envHumidityNormal NOTIFICATION-TYPE INFORMATION: The environment humidity is normal. | 1.3.6.1.4.1.935.0.19 | |
| envSmokeAbnormal NOTIFICATION-TYPE WARNING: Smoke is abnormal. | 1.3.6.1.4.1.935.0.20 | |
| envWaterAbnormal NOTIFICATION-TYPE WARNING: Water is abnormal. | 1.3.6.1.4.1.935.0.21 | |
| envSecurityAbnormal NOTIFICATION-TYPE WARNING: Security is abnormal. | 1.3.6.1.4.1.935.0.22 | |
| envWaterNormal NOTIFICATION-TYPE INFORMATION: Water is normal. | 1.3.6.1.4.1.935.0.24 | |
| envGasAbnormal NOTIFICATION-TYPE WARNING: Gas Alarm | 1.3.6.1.4.1.935.0.26 | |
| upsTemp NOTIFICATION-TYPE WARNING: UPS Temperature Overrun | 1.3.6.1.4.1.935.0.27 | |
| upsLoadNormal NOTIFICATION-TYPE WARNING: UPS Load Normal | 1.3.6.1.4.1.935.0.28 | |
| upsTempNormal NOTIFICATION-TYPE WARNING: UPS temperature Normal | 1.3.6.1.4.1.935.0.29 | |
| envUnderTemperature NOTIFICATION-TYPE WARNING: The environment temperature below the normal value. | 1.3.6.1.4.1.935.0.30 | |
| envUnderHumidity NOTIFICATION-TYPE WARNING: The environment humidity below the normal value. | 1.3.6.1.4.1.935.0.31 | |
| upsBypass NOTIFICATION-TYPE WARNING: The UPS is entering 'bypass' mode. | 1.3.6.1.4.1.935.0.32 | |
| envSecurity1 NOTIFICATION-TYPE WARNING: Security1 Alarm. | 1.3.6.1.4.1.935.0.33 | |
| envSecurity2 NOTIFICATION-TYPE WARNING: Security2 Alarm. | 1.3.6.1.4.1.935.0.34 | |
| envSecurity3 NOTIFICATION-TYPE WARNING: Security3 Alarm. | 1.3.6.1.4.1.935.0.35 | |
| envSecurity4 NOTIFICATION-TYPE WARNING: Security4 Alarm. | 1.3.6.1.4.1.935.0.36 | |
| envSecurity5 NOTIFICATION-TYPE WARNING: Security5 Alarm. | 1.3.6.1.4.1.935.0.37 | |
| envSecurity6 NOTIFICATION-TYPE WARNING: Security6 Alarm. | 1.3.6.1.4.1.935.0.38 | |
| envSecurity7 NOTIFICATION-TYPE WARNING: Security7 Alarm. | 1.3.6.1.4.1.935.0.39 | |
| upsRecroterror NOTIFICATION-TYPE WARNING: Rectifier Rotation Error | 1.3.6.1.4.1.935.0.47 | |
| upsBypassFreFail NOTIFICATION-TYPE WARNING: Bypass Frequency Fail | 1.3.6.1.4.1.935.0.48 | |
| upsBypassacnormal NOTIFICATION-TYPE WARNING: Bypass AC Normal | 1.3.6.1.4.1.935.0.49 | |
| upsBypassacabnormal NOTIFICATION-TYPE WARNING: Bypass AC Abnormal | 1.3.6.1.4.1.935.0.50 | |
| upsTest NOTIFICATION-TYPE WARNING: UPS Test | 1.3.6.1.4.1.935.0.51 | |
| upsScheduleShutdown NOTIFICATION-TYPE WARNING: UPS Schedule Shutdown | 1.3.6.1.4.1.935.0.52 | |
| upsBypassReturn NOTIFICATION-TYPE The UPS return from Bypass Mode | 1.3.6.1.4.1.935.0.53 | |
| upsShortCircuitShutdown NOTIFICATION-TYPE The UPS Short Circuit Shutdown | 1.3.6.1.4.1.935.0.54 | |
| upsInverterOutputFailShutdown NOTIFICATION-TYPE The UPS Inverter Output Fail Shutdown | 1.3.6.1.4.1.935.0.55 | |
| upsBypassBreadkerOnShutdown NOTIFICATION-TYPE The UPS Manual Bypass Breaker on Shutdown | 1.3.6.1.4.1.935.0.56 | |
| upsHighDCShutdown NOTIFICATION-TYPE The UPS High DC Shutdown | 1.3.6.1.4.1.935.0.57 | |
| upsEmergencyStop NOTIFICATION-TYPE The UPS Emergency Stop | 1.3.6.1.4.1.935.0.58 | |
| upsInverterMode NOTIFICATION-TYPE The UPS Static Switch in Inverter Mode | 1.3.6.1.4.1.935.0.59 | |
| upsBypassMode NOTIFICATION-TYPE The UPS Static Switch in Bypass Mode | 1.3.6.1.4.1.935.0.60 | |
| upsOverTemperatureShutdown NOTIFICATION-TYPE The UPS Over Temperature Shutdown | 1.3.6.1.4.1.935.0.61 | |
| upsOverLoadShutdown NOTIFICATION-TYPE The UPS Overload Shutdown | 1.3.6.1.4.1.935.0.62 | |
| upsCapacityUnderrun NOTIFICATION-TYPE The UPS Capacity Underrun | 1.3.6.1.4.1.935.0.63 | |
| upsCapacityNormal NOTIFICATION-TYPE The UPS Capacity Normal | 1.3.6.1.4.1.935.0.64 | |
| upsLowBatteryShutdown NOTIFICATION-TYPE The UPS Low Battery Shutdown | 1.3.6.1.4.1.935.0.67 | |
| buckOn NOTIFICATION-TYPE WARNING: The UPS has enabled Buck. | 1.3.6.1.4.1.935.0.68 | |
| returnFromBuck NOTIFICATION-TYPE WARNING: The UPS has return from Buck. | 1.3.6.1.4.1.935.0.69 | |
| returnFromBoost NOTIFICATION-TYPE WARNING: The UPS has return from Boost. | 1.3.6.1.4.1.935.0.70 |