MIBs Depot

XPPC-MIB

Registered at
1.3.6.1.4.1.935.1
1.3.6.1.4.1.935.2
Namespace
logmaster
Source file
XPPC-MIB
Digest
sha256:63865bfa1f6cc6155562a6efde699598722136220e944d81887d3abde73fc757

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
XPPC-MIB

Objects

NameOIDSyntaxAccessStatus
ppc
OBJECT-IDENTITY
1.3.6.1.4.1.935
products
OBJECT-IDENTITY
1.3.6.1.4.1.935.1
hardware
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1
ups
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1
upsIdentp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.1
upsBaseIdent
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.1.1
upsBaseIdentModel
OBJECT-TYPE
The UPS model name (e.g. 'Intelligent 8000E 900VA').
1.3.6.1.4.1.935.1.1.1.1.1.1DisplayStringread-onlymandatory
upsBaseIdentUpsName
OBJECT-TYPE
An 8 byte ID string identifying the UPS. This object can be set by the administrator.
1.3.6.1.4.1.935.1.1.1.1.1.2DisplayStringread-writemandatory
upsSmartIdent
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.1.2
upsSmartIdentFirmwareRevision
OBJECT-TYPE
The firmware revision of the UPS system.
1.3.6.1.4.1.935.1.1.1.1.2.1DisplayStringread-onlymandatory
upsSmartIdentDateOfManufacture
OBJECT-TYPE
The date when the UPS was manufactured in mm/dd/yy format.
1.3.6.1.4.1.935.1.1.1.1.2.2DisplayStringread-onlymandatory
upsSmartIdentUpsSerialNumber
OBJECT-TYPE
An 8-character string identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspond to the serial number on the rear of the UPS.
1.3.6.1.4.1.935.1.1.1.1.2.3DisplayStringread-onlymandatory
upsSmartIdentAgentFirmwareRevision
OBJECT-TYPE
The firmware revision of the UPS SNMP Proxy agent.
1.3.6.1.4.1.935.1.1.1.1.2.4DisplayStringread-onlymandatory
upsBatteryp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.2
upsBaseBattery
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.2.1
upsBaseBatteryStatus
OBJECT-TYPE
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsSmartConfigLowBatteryRunTime.
1.3.6.1.4.1.935.1.1.1.2.1.1INTEGER {unknown(1), batteryNormal(2), batteryLow(3)}read-onlymandatory
upsBaseBatteryTimeOnBattery
OBJECT-TYPE
The elapsed time in seconds since the UPS has switched to battery power.
1.3.6.1.4.1.935.1.1.1.2.1.2INTEGERread-onlymandatory
upsBaseBatteryLastReplaceDate
OBJECT-TYPE
The date when the UPS system's batteries were last replaced in mm/dd/yy format. For UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator.
1.3.6.1.4.1.935.1.1.1.2.1.3DisplayStringread-writemandatory
upsSmartBattery
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.2.2
upsSmartBatteryCapacity
OBJECT-TYPE
The remaining battery capacity expressed in percent of full capacity.
1.3.6.1.4.1.935.1.1.1.2.2.1INTEGERread-onlymandatory
upsSmartBatteryVoltage
OBJECT-TYPE
The current battery voltage expressed in 1/10 VDC.
1.3.6.1.4.1.935.1.1.1.2.2.2INTEGERread-onlymandatory
upsSmartBatteryTemperature
OBJECT-TYPE
The current internal UPS temperature expressed in tenths of a Celsius degree.
1.3.6.1.4.1.935.1.1.1.2.2.3INTEGERread-onlymandatory
upsSmartBatteryRunTimeRemaining
OBJECT-TYPE
The UPS battery run time remaining before battery exhaustion, in seconds.
1.3.6.1.4.1.935.1.1.1.2.2.4INTEGERread-onlymandatory
upsSmartBatteryReplaceIndicator
OBJECT-TYPE
Indicates whether the UPS batteries need replacing.
1.3.6.1.4.1.935.1.1.1.2.2.5INTEGER {noBatteryNeedsReplacing(1), batteryNeedsReplacing(2)}read-onlymandatory
upsSmartBatteryFullChargeVoltage
OBJECT-TYPE
The fully charged battery voltage of the battery system used in the UPS, expressed in tenths of a volt.
1.3.6.1.4.1.935.1.1.1.2.2.6INTEGERread-onlymandatory
upsSmartBatteryCurrent
OBJECT-TYPE
The current battery current expressed in percent of maximum current.
1.3.6.1.4.1.935.1.1.1.2.2.7INTEGERread-onlymandatory
upsInputp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.3
upsBaseInput
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.3.1
upsBaseInputPhase
OBJECT-TYPE
The current AC input phase.
1.3.6.1.4.1.935.1.1.1.3.1.1INTEGERread-onlymandatory
upsSmartInput
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.3.2
upsSmartInputLineVoltage
OBJECT-TYPE
The current utility line voltage in 1/10 VAC.
1.3.6.1.4.1.935.1.1.1.3.2.1INTEGERread-onlymandatory
upsSmartInputMaxLineVoltage
OBJECT-TYPE
The maximum utility line voltage in 1/10 VAC over the previous 1 minute period.
1.3.6.1.4.1.935.1.1.1.3.2.2INTEGERread-onlymandatory
upsSmartInputMinLineVoltage
OBJECT-TYPE
The minimum utility line voltage in 1/10 VAC over the previous 1 minute period.
1.3.6.1.4.1.935.1.1.1.3.2.3INTEGERread-onlymandatory
upsSmartInputFrequency
OBJECT-TYPE
The current input frequency to the UPS system in 1/10 Hz.
1.3.6.1.4.1.935.1.1.1.3.2.4INTEGERread-onlymandatory
upsSmartInputLineFailCause
OBJECT-TYPE
The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground.
1.3.6.1.4.1.935.1.1.1.3.2.5INTEGER {noTransfer(1), highLineVoltage(2), brownout(3), blackout(4), smallMomentarySag(5), deepMomentarySag(6), smallMomentarySpike(7), largeMomentarySpike(8)}read-onlymandatory
upsOutputp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.4
upsBaseOutput
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.4.1
upsBaseOutputStatus
OBJECT-TYPE
The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1).
1.3.6.1.4.1.935.1.1.1.4.1.1INTEGER {unknown(1), onLine(2), onBattery(3), onBoost(4), sleeping(5), onBypass(6), rebooting(7), standBy(8), onBuck(9)}read-onlymandatory
upsBaseOutputPhase
OBJECT-TYPE
The current output phase.
1.3.6.1.4.1.935.1.1.1.4.1.2INTEGERread-onlymandatory
upsSmartOutput
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.4.2
upsSmartOutputVoltage
OBJECT-TYPE
The output voltage of the UPS system in 1/10 VAC.
1.3.6.1.4.1.935.1.1.1.4.2.1INTEGERread-onlymandatory
upsSmartOutputFrequency
OBJECT-TYPE
The current output frequency of the UPS system in 1/10 Hz.
1.3.6.1.4.1.935.1.1.1.4.2.2INTEGERread-onlymandatory
upsSmartOutputLoad
OBJECT-TYPE
The current UPS load expressed in percent of rated capacity.
1.3.6.1.4.1.935.1.1.1.4.2.3INTEGERread-onlymandatory
upsConfigp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.5
upsBaseConfig
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.5.1
upsBaseConfigNumDevices
OBJECT-TYPE
The number of devices that are plugged into the UPS.
1.3.6.1.4.1.935.1.1.1.5.1.1INTEGERread-onlymandatory
upsBaseConfigDeviceTable
OBJECT-TYPE
A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBaseConfigNumDevices.
1.3.6.1.4.1.935.1.1.1.5.1.2not-accessiblemandatory
upsBaseConfigDeviceEntry
OBJECT-TYPE
The devices plugged in to the UPS.
1.3.6.1.4.1.935.1.1.1.5.1.2.1not-accessiblemandatory
indexOfDevice
OBJECT-TYPE
The index of the device that is plugged into the UPS.
1.3.6.1.4.1.935.1.1.1.5.1.2.1.1INTEGERread-onlymandatory
nameOfDevice
OBJECT-TYPE
The name/description of the device plugged into the UPS.
1.3.6.1.4.1.935.1.1.1.5.1.2.1.2DisplayStringread-writemandatory
vaRatingOfDevice
OBJECT-TYPE
The volt-amp rating of the device plugged into the UPS.
1.3.6.1.4.1.935.1.1.1.5.1.2.1.3INTEGERread-writemandatory
deviceAccept
OBJECT-TYPE
An entry is added if yes, the entry is deleted if no.
1.3.6.1.4.1.935.1.1.1.5.1.2.1.4INTEGER {yes(1), no(2)}read-writemandatory
upsSmartConfig
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.5.2
upsSmartConfigRatedOutputVoltage
OBJECT-TYPE
The nominal output voltage from the UPS in 1/10 VAC. Possible values are 1000, 1200, 2080, 2200, 2250, 2300 and 2400. NOTE: Only units that are 2200, 2250, 2300 and 2400 can be changed. Allowable values are 2200, 2250, 2300 and 2400. For these adjustable units, if a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.1INTEGERread-writemandatory
upsSmartConfigHighTransferVolt
OBJECT-TYPE
The maximum line voltage in 1/10 VAC allowed before the UPS system transfers to battery backup. Allowed value depend on the UPS used: 120 Volt units allow settings of 1290, 1320, 1350, 1380. 100 Volt units allow settings of 1080, 1100, 1120, 1140. 230 Volt units allow settings of 2530, 2640, 2710, 2800. 208 Volt units allow settings of 2240, 2290, 2340, 2390. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.2INTEGERread-writemandatory
upsSmartConfigLowTransferVolt
OBJECT-TYPE
The minimum line voltage in 1/10 VAC allowed before the UPS system transfers to battery backup. Allowable values depend on the UPS used: 120 Volt units allow settings of 970, 1000, 1030, 1060. 100 Volt units allow settings of 810, 830, 850, 870. 230 Volt units allow settings of 1880, 1960, 2040, 2080. 208 Volt units allow settings of 1680, 1720, 1770, 1820. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.3INTEGERread-writemandatory
upsSmartConfigAlarm
OBJECT-TYPE
A flag indicating how the UPS should handle audible line fail alarms.
1.3.6.1.4.1.935.1.1.1.5.2.4INTEGER {timed(1), atLowBattery(2), never(3)}read-writemandatory
upsSmartConfigAlarmTimer
OBJECT-TYPE
The time in seconds after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observerd only if the value of extControlAlarm is timed(2). Allowed values are 0 or 30 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.5INTEGERread-writemandatory
upsSmartConfigMinReturnCapacity
OBJECT-TYPE
The minimum battery capacity as a percent of full capacity required before the UPS will return from a low battery shutdown condition. In other words, the UPS will not re-energize the output until the battery capacity is equal to this value. Allowed values are 0, 10, 25, or 90 percent. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.6INTEGERread-writemandatory
upsSmartConfigSensitivity
OBJECT-TYPE
The sensitivity of the UPS to utility line abnormalities or noises.
1.3.6.1.4.1.935.1.1.1.5.2.7INTEGER {auto(1), low(2), medium(3), high(4)}read-writemandatory
upsSmartConfigLowBatteryRunTime
OBJECT-TYPE
The desired run time in seconds once the low battery condition is reached. Allowed values are 120, 300, 420, or 600 seconds. During this time the UPS will produce a constant warning tone which can not be disabled. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.8INTEGERread-writemandatory
upsSmartConfigReturnDelay
OBJECT-TYPE
The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UPS wakes up from 'sleep' mode. Allowed values are 0, 60, 180 and 300 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.9INTEGERread-writemandatory
upsSmartConfigShutoffDelay
OBJECT-TYPE
The delay in seconds the UPS remains on after being told to turn off. Allowed values are 12, 18, 24, 30, 36, 42, 48, 54, 60, 120, 180, 240, 300, 360, 420, 480, 540, and 600 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.10INTEGERread-writemandatory
upsSmartConfigUpsSleepTime
OBJECT-TYPE
The time in minutes for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 0 - 9999 minutes in one minute increments. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.935.1.1.1.5.2.11INTEGERread-writemandatory
upsSmartConfigSetEEPROMDefaults
OBJECT-TYPE
WRITE: Resets the UPS EEPROM variables to default values. READ: returns 0
1.3.6.1.4.1.935.1.1.1.5.2.12INTEGER {noSetEEPROMDefaults(1), setEEPROMDefaults(2)}read-writemandatory
upsControlp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.6
upsBaseControl
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.6.1
upsBaseControlConserveBattery
OBJECT-TYPE
Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode immediately. The (10) means suspending time(10 minutes) before turn off UPS. UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.1.1INTEGER {noTurnOffUps(1), turnUpsOffToConserveBattery(2), turnUpsOffToConserveBatteryDelay(3)}read-writemandatory
upsSmartControl
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.6.2
upsSmartControlUpsOff
OBJECT-TYPE
Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state. The on/off switch on the UPS must be toggled for the UPS to return to operation. Setting this value to noTurnUpsOff(1) has no effect. The value noTurnUpsOff(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.1INTEGER {noTurnUpsOff(1), turnUpsOff(2)}read-writemandatory
upsSmartControlRebootUps
OBJECT-TYPE
Setting this variable to rebootUps(2) causes the UPS to shut off and turn back on. Setting this value to noRebootUps(1) has no effect. The value noRebootUps(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.2INTEGER {noRebootUps(1), rebootUps(2)}read-writemandatory
upsSmartControlUpsSleep
OBJECT-TYPE
Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsSmartConfigUpsSleepTime. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. Setting this value to noPutUpsToSleep(1) has no effect. The value noPutUpsToSleep(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.3INTEGER {noPutUpsToSleep(1), putUpsToSleep(2)}read-writemandatory
upsSmartControlSimulatePowerFail
OBJECT-TYPE
Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The value noSimulatePowerFailure(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.4INTEGER {noSimulatePowerFailure(1), simulatePowerFailure(2)}read-writemandatory
upsSmartControlFlashAndBeep
OBJECT-TYPE
UPS to identify itself by lighting all indicators and beeping. Setting this variable to FlashAndBeep(2) causes the UPS lights all panel indicators and beeps. Setting this value to noFlashAndBeep(1) has no effect. The value noFlashAndBeep(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.5INTEGER {noFlashAndBeep(1), flashAndBeep(2)}read-writemandatory
upsSmartControlTurnOnUpsLoad
OBJECT-TYPE
Setting this variable to upsSmartControlTurnOnUpsLoad(2) causes the UPS switch back to utility power if utility power is present. Setting this value to noUpsSmartControlTurnOnUpsLoad(1) has no effect. The value noUpsSmartControlTurnOnUpsLoad(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.6.2.6INTEGER {noUpsSmartControlTurnOnUpsLoad(1), upsSmartControlTurnOnUpsLoad(2)}read-writemandatory
upsTestp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.7
upsBaseTest
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.7.1
upsSmartTest
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.7.2
upsSmartTestDiagnosticSchedule
OBJECT-TYPE
The UPS system's automatic battery test schedule.
1.3.6.1.4.1.935.1.1.1.7.2.1INTEGER {unknown(1), biweekly(2), weekly(3), never(4)}read-writemandatory
upsSmartTestDiagnostics
OBJECT-TYPE
Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The value noTestDiagnostics(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.7.2.2INTEGER {noTestDiagnostics(1), testDiagnostics(2)}read-writemandatory
upsSmartTestDiagnosticsResults
OBJECT-TYPE
The results of the last UPS diagnostics test performed.
1.3.6.1.4.1.935.1.1.1.7.2.3INTEGER {ok(1), failed(2), invalidTest(3), testInProgress(4)}read-onlymandatory
upsSmartTestLastDiagnosticsDate
OBJECT-TYPE
The date the last UPS diagnostics test was performed in mm/dd/yy format.
1.3.6.1.4.1.935.1.1.1.7.2.4DisplayStringread-onlymandatory
upsSmartTestIndicators
OBJECT-TYPE
Setting this variable to testIndicators(2) causes the UPS to perform a front panel indicator (lights) test. Setting this value to noTestIndicators(1) has no effect. The value noTestIndicators(1) will always be returned when the variable is read.
1.3.6.1.4.1.935.1.1.1.7.2.5INTEGER {noTestIndicators(1), testIndicators(2)}read-writemandatory
upsSmartTestRuntimeCalibration
OBJECT-TYPE
Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult.
1.3.6.1.4.1.935.1.1.1.7.2.6INTEGER {noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3)}read-writemandatory
upsSmartTestCalibrationResults
OBJECT-TYPE
The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidTest(2) indicates last calibration did not take place since the battery capacity was below 100 percent. Value calibrationInProgress(3) means a calibration is occurring now.
1.3.6.1.4.1.935.1.1.1.7.2.7INTEGER {ok(1), invalidTest(2), calibrationInProgress(3)}read-onlymandatory
upsSmartTestCalibrationDate
OBJECT-TYPE
The date the last UPS runtime calibration was performed in mm/dd/yy format.
1.3.6.1.4.1.935.1.1.1.7.2.8DisplayStringread-onlymandatory
upsThreePhase
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8
upsThreePhaseBatteryGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.1
upsThreePhaseBatteryVoltage
OBJECT-TYPE
Battery Voltage
1.3.6.1.4.1.935.1.1.1.8.1.1INTEGERread-onlymandatory
upsThreePhaseBatteryCapacityPercentage
OBJECT-TYPE
Battery Capacity Percentage
1.3.6.1.4.1.935.1.1.1.8.1.2INTEGERread-onlymandatory
upsThreePhaseBatteryTimeRemain
OBJECT-TYPE
Battery Time Remain (unit is Minute)
1.3.6.1.4.1.935.1.1.1.8.1.3INTEGERread-onlymandatory
upsThreePhaseBatteryCurrent
OBJECT-TYPE
Battery Electric Current
1.3.6.1.4.1.935.1.1.1.8.1.4INTEGERread-onlymandatory
upsThreePhaseBatteryTemperature
OBJECT-TYPE
Battery Temperature
1.3.6.1.4.1.935.1.1.1.8.1.5INTEGERread-onlymandatory
upsThreePhaseInputGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.2
upsThreePhaseInputFrequency
OBJECT-TYPE
Input Frequency
1.3.6.1.4.1.935.1.1.1.8.2.1INTEGERread-onlymandatory
upsThreePhaseInputVoltageR
OBJECT-TYPE
Input VoltageR
1.3.6.1.4.1.935.1.1.1.8.2.2INTEGERread-onlymandatory
upsThreePhaseInputVoltageS
OBJECT-TYPE
Input VoltageS
1.3.6.1.4.1.935.1.1.1.8.2.3INTEGERread-onlymandatory
upsThreePhaseInputVoltageT
OBJECT-TYPE
Input VoltageT
1.3.6.1.4.1.935.1.1.1.8.2.4INTEGERread-onlymandatory
upsThreePhaseOutputGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.3
upsThreePhaseOutputFrequency
OBJECT-TYPE
Output Frequency
1.3.6.1.4.1.935.1.1.1.8.3.1INTEGERread-onlymandatory
upsThreePhaseOutputVoltageR
OBJECT-TYPE
Output VoltageR
1.3.6.1.4.1.935.1.1.1.8.3.2INTEGERread-onlymandatory
upsThreePhaseOutputVoltageS
OBJECT-TYPE
Output VoltageS
1.3.6.1.4.1.935.1.1.1.8.3.3INTEGERread-onlymandatory
upsThreePhaseOutputVoltageT
OBJECT-TYPE
Output VoltageT
1.3.6.1.4.1.935.1.1.1.8.3.4INTEGERread-onlymandatory
upsThreePhaseOutputLoadPercentageR
OBJECT-TYPE
Load PercentageR
1.3.6.1.4.1.935.1.1.1.8.3.5INTEGERread-onlymandatory
upsThreePhaseOutputLoadPercentageS
OBJECT-TYPE
Load PercentageS
1.3.6.1.4.1.935.1.1.1.8.3.6INTEGERread-onlymandatory
upsThreePhaseOutputLoadPercentageT
OBJECT-TYPE
Load PercentageT
1.3.6.1.4.1.935.1.1.1.8.3.7INTEGERread-onlymandatory
upsThreePhaseBypassGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.4
upsThreePhaseBypassSourceFrequency
OBJECT-TYPE
Bypass Frequency
1.3.6.1.4.1.935.1.1.1.8.4.1INTEGERread-onlymandatory
upsThreePhaseBypssSourceVoltageR
OBJECT-TYPE
Bypass VoltageR
1.3.6.1.4.1.935.1.1.1.8.4.2INTEGERread-onlymandatory
upsThreePhaseBypssSourceVoltageS
OBJECT-TYPE
Bypass VoltageS
1.3.6.1.4.1.935.1.1.1.8.4.3INTEGERread-onlymandatory
upsThreePhaseBypssSourceVoltageT
OBJECT-TYPE
Bypass VoltageT
1.3.6.1.4.1.935.1.1.1.8.4.4INTEGERread-onlymandatory
upsThreePhaseDCandRectifierStatusGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.5
upsThreePhaseDCandRectifierStatusRecRotError
OBJECT-TYPE
Rectifier Rotation Error
1.3.6.1.4.1.935.1.1.1.8.5.1INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseDCandRectifierStatusLowBatteryShutdown
OBJECT-TYPE
Low Battery Shutdown
1.3.6.1.4.1.935.1.1.1.8.5.2INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseDCandRectifierStatusLowBattery
OBJECT-TYPE
Low Battery
1.3.6.1.4.1.935.1.1.1.8.5.3INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseDCandRectifierStatusInAndOut
OBJECT-TYPE
In And Put
1.3.6.1.4.1.935.1.1.1.8.5.4INTEGER {threeInOneOut(2), threeInThreeOut(3)}read-onlymandatory
upsThreePhaseDCandRectifierStatusBatteryStatus
OBJECT-TYPE
Back Status
1.3.6.1.4.1.935.1.1.1.8.5.5INTEGER {backup(4), acnormal(5)}read-onlymandatory
upsThreePhaseDCandRectifierStatusChargeStatus
OBJECT-TYPE
Charge Status
1.3.6.1.4.1.935.1.1.1.8.5.6INTEGER {boost(6), float(7), no(16)}read-onlymandatory
upsThreePhaseDCandRectifierStatusRecOperating
OBJECT-TYPE
Rectifier Operating
1.3.6.1.4.1.935.1.1.1.8.5.7INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseUPSStatusGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.6
upsThreePhaseUPSStatusBypassFreqFail
OBJECT-TYPE
Bypass Status
1.3.6.1.4.1.935.1.1.1.8.6.1INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseUPSStatusManualBypassBreaker
OBJECT-TYPE
Breaker Status
1.3.6.1.4.1.935.1.1.1.8.6.2INTEGER {close(8), open(9)}read-onlymandatory
upsThreePhaseUPSStatusACStatus
OBJECT-TYPE
AC Status
1.3.6.1.4.1.935.1.1.1.8.6.3INTEGER {normal(10), abnormal(11)}read-onlymandatory
upsThreePhaseUPSStaticSwitchMode
OBJECT-TYPE
Switch Mode
1.3.6.1.4.1.935.1.1.1.8.6.4INTEGER {invermode(12), bypassmode(13)}read-onlymandatory
upsThreePhaseUPSStatusInverterOperating
OBJECT-TYPE
Operating
1.3.6.1.4.1.935.1.1.1.8.6.5INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.7
upsThreePhaseFaultStatusEmergencyStop
OBJECT-TYPE
Emergency Stop
1.3.6.1.4.1.935.1.1.1.8.7.1INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusHighDCShutdown
OBJECT-TYPE
High DC Shutdown
1.3.6.1.4.1.935.1.1.1.8.7.2INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusBypassBreaker
OBJECT-TYPE
Bypass Breaker
1.3.6.1.4.1.935.1.1.1.8.7.3INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusOverLoad
OBJECT-TYPE
Over Load
1.3.6.1.4.1.935.1.1.1.8.7.4INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusInverterOutputFail
OBJECT-TYPE
Output Fail
1.3.6.1.4.1.935.1.1.1.8.7.5INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusOverTemperature
OBJECT-TYPE
Over Temperature
1.3.6.1.4.1.935.1.1.1.8.7.6INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseFaultStatusShortCircuit
OBJECT-TYPE
Short Circuit
1.3.6.1.4.1.935.1.1.1.8.7.7INTEGER {yes(14), no(16)}read-onlymandatory
upsThreePhaseRatingGrp
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.8.8
upsThreePhaseRatingRectifierVoltage
OBJECT-TYPE
Rectifier Voltage
1.3.6.1.4.1.935.1.1.1.8.8.1DisplayStringread-onlymandatory
upsThreePhaseRatingRectifierFrequency
OBJECT-TYPE
Rectifier Frequency
1.3.6.1.4.1.935.1.1.1.8.8.2INTEGERread-onlymandatory
upsThreePhaseRatingBypassVoltage
OBJECT-TYPE
Bypass Voltage
1.3.6.1.4.1.935.1.1.1.8.8.3DisplayStringread-onlymandatory
upsThreePhaseRatingBypassFrequency
OBJECT-TYPE
Bypass Frequency
1.3.6.1.4.1.935.1.1.1.8.8.4INTEGERread-onlymandatory
upsThreePhaseRatingOutputVoltage
OBJECT-TYPE
Output Voltage
1.3.6.1.4.1.935.1.1.1.8.8.5DisplayStringread-onlymandatory
upsThreePhaseRatingOutputFrequency
OBJECT-TYPE
Output Frequency
1.3.6.1.4.1.935.1.1.1.8.8.6INTEGERread-onlymandatory
upsThreePhaseRatingBatteryVoltage
OBJECT-TYPE
Battery Voltage
1.3.6.1.4.1.935.1.1.1.8.8.7INTEGERread-onlymandatory
upsThreePhaseRatingPower
OBJECT-TYPE
Power Rating
1.3.6.1.4.1.935.1.1.1.8.8.8DisplayStringread-onlymandatory
upsEnvironment
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.9
upsEnvStatus
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.9.1
upsEnvTemperature
OBJECT-TYPE
The ambient environment temperature.
1.3.6.1.4.1.935.1.1.1.9.1.1INTEGERread-onlymandatory
upsEnvHumidity
OBJECT-TYPE
The environment humidity.
1.3.6.1.4.1.935.1.1.1.9.1.2INTEGERread-onlymandatory
upsEnvWater
OBJECT-TYPE
Water status
1.3.6.1.4.1.935.1.1.1.9.1.3INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSmoke
OBJECT-TYPE
Smoke status
1.3.6.1.4.1.935.1.1.1.9.1.4INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity1
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.5INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity2
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.6INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity3
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.7INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity4
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.8INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity5
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.9INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity6
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.10INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSecurity7
OBJECT-TYPE
Security status
1.3.6.1.4.1.935.1.1.1.9.1.11INTEGER {normal(1), abnormal(2)}read-onlymandatory
upsEnvSetting
OBJECT-IDENTITY
1.3.6.1.4.1.935.1.1.1.9.2
upsEnvOverTemperature
OBJECT-TYPE
Alarm dupsAlarmOverTemperature on when the environment temperature over the value.
1.3.6.1.4.1.935.1.1.1.9.2.1INTEGERread-writemandatory
upsEnvUnderTemperature
OBJECT-TYPE
Alarm dupsAlarmUnderTemperature on when the environment temperature below the value.
1.3.6.1.4.1.935.1.1.1.9.2.2INTEGERread-writemandatory
upsEnvOverHumidity
OBJECT-TYPE
Alarm dupsAlarmOverHumidity on when the environment humidity over the value.
1.3.6.1.4.1.935.1.1.1.9.2.3INTEGERread-writemandatory
upsEnvUnderHumidity
OBJECT-TYPE
Alarm dupsAlarmUnderHumidity on when the environment humidity below the value.
1.3.6.1.4.1.935.1.1.1.9.2.4INTEGERread-writemandatory
ppcmgmt
OBJECT-IDENTITY
1.3.6.1.4.1.935.2
mconfig
OBJECT-IDENTITY
1.3.6.1.4.1.935.2.1
mconfigTrapsReceiversNum
OBJECT-TYPE
The number of managers to send traps to.
1.3.6.1.4.1.935.2.1.1INTEGERread-onlymandatory
mconfigTrapsReceiversTable
OBJECT-TYPE
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers
1.3.6.1.4.1.935.2.1.2not-accessiblemandatory
mconfigTrapsReceiversEntry
OBJECT-TYPE
The managers to send traps to.
1.3.6.1.4.1.935.2.1.2.1not-accessiblemandatory
trapsIndex
OBJECT-TYPE
The index to a trap receiver entry.
1.3.6.1.4.1.935.2.1.2.1.1INTEGERread-onlymandatory
trapsReceiverAddr
OBJECT-TYPE
The IP address of the manager to send a trap to.
1.3.6.1.4.1.935.2.1.2.1.2IpAddressread-writemandatory
receiverCommunityString
OBJECT-TYPE
The community name to use in the trap when sent to the manager.
1.3.6.1.4.1.935.2.1.2.1.3DisplayStringread-writemandatory
severityLevel
OBJECT-TYPE
The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager.
1.3.6.1.4.1.935.2.1.2.1.4INTEGER {information(1), warning(2), severe(3)}read-writemandatory
receiverAccept
OBJECT-TYPE
An entry will become active if yes, and will be deleted if no.
1.3.6.1.4.1.935.2.1.2.1.5INTEGER {yes(1), no(2)}read-writemandatory

Notifications

NameOIDStatus
communicationLost
NOTIFICATION-TYPE
SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress.
1.3.6.1.4.1.935.0.1
upsOverLoad
NOTIFICATION-TYPE
SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.
1.3.6.1.4.1.935.0.2
upsDiagnosticsFailed
NOTIFICATION-TYPE
SEVERE: The UPS failed its internal diagnostic self-test.
1.3.6.1.4.1.935.0.3
upsDischarged
NOTIFICATION-TYPE
SEVERE: The UPS just started a runtime calibration discharge. The UPS batteries are being discharged.
1.3.6.1.4.1.935.0.4
upsOnBattery
NOTIFICATION-TYPE
WARNING: The UPS has switched to battery backup power.
1.3.6.1.4.1.935.0.5
boostOn
NOTIFICATION-TYPE
WARNING: The UPS has enabled Boost.
1.3.6.1.4.1.935.0.6
lowBattery
NOTIFICATION-TYPE
SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load.
1.3.6.1.4.1.935.0.7
communicationEstablished
NOTIFICATION-TYPE
INFORMATION: Communication with the UPS has been established.
1.3.6.1.4.1.935.0.8
powerRestored
NOTIFICATION-TYPE
INFORMATION: Utility power has been restored.
1.3.6.1.4.1.935.0.9
upsDiagnosticsPassed
NOTIFICATION-TYPE
INFORMATION: The UPS passed its internal self-test.
1.3.6.1.4.1.935.0.10
returnFromLowBattery
NOTIFICATION-TYPE
INFORMATION: The UPS has returned from a low battery condition.
1.3.6.1.4.1.935.0.11
upsTurnedOff
NOTIFICATION-TYPE
WARNING: The UPS has been turned 'off' by the management station.
1.3.6.1.4.1.935.0.12
upsSleeping
NOTIFICATION-TYPE
WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off.
1.3.6.1.4.1.935.0.13
upsWokeUp
NOTIFICATION-TYPE
INFORMATION: The UPS woke up from 'sleep' mode. Power to the load has been restored.
1.3.6.1.4.1.935.0.14
upsRebootStarted
NOTIFICATION-TYPE
WARNING: The UPS has started its reboot sequence. After the specified delay the UPS will perform a reboot.
1.3.6.1.4.1.935.0.15
envOverTemperature
NOTIFICATION-TYPE
WARNING: The environment temperature exceed the normal value.
1.3.6.1.4.1.935.0.16
envTemperatureNormal
NOTIFICATION-TYPE
INFORMATION: The environment temperature is normal.
1.3.6.1.4.1.935.0.17
envOverHumidity
NOTIFICATION-TYPE
WARNING: The environment humidity exceed the normal value.
1.3.6.1.4.1.935.0.18
envHumidityNormal
NOTIFICATION-TYPE
INFORMATION: The environment humidity is normal.
1.3.6.1.4.1.935.0.19
envSmokeAbnormal
NOTIFICATION-TYPE
WARNING: Smoke is abnormal.
1.3.6.1.4.1.935.0.20
envWaterAbnormal
NOTIFICATION-TYPE
WARNING: Water is abnormal.
1.3.6.1.4.1.935.0.21
envSecurityAbnormal
NOTIFICATION-TYPE
WARNING: Security is abnormal.
1.3.6.1.4.1.935.0.22
envWaterNormal
NOTIFICATION-TYPE
INFORMATION: Water is normal.
1.3.6.1.4.1.935.0.24
envGasAbnormal
NOTIFICATION-TYPE
WARNING: Gas Alarm
1.3.6.1.4.1.935.0.26
upsTemp
NOTIFICATION-TYPE
WARNING: UPS Temperature Overrun
1.3.6.1.4.1.935.0.27
upsLoadNormal
NOTIFICATION-TYPE
WARNING: UPS Load Normal
1.3.6.1.4.1.935.0.28
upsTempNormal
NOTIFICATION-TYPE
WARNING: UPS temperature Normal
1.3.6.1.4.1.935.0.29
envUnderTemperature
NOTIFICATION-TYPE
WARNING: The environment temperature below the normal value.
1.3.6.1.4.1.935.0.30
envUnderHumidity
NOTIFICATION-TYPE
WARNING: The environment humidity below the normal value.
1.3.6.1.4.1.935.0.31
upsBypass
NOTIFICATION-TYPE
WARNING: The UPS is entering 'bypass' mode.
1.3.6.1.4.1.935.0.32
envSecurity1
NOTIFICATION-TYPE
WARNING: Security1 Alarm.
1.3.6.1.4.1.935.0.33
envSecurity2
NOTIFICATION-TYPE
WARNING: Security2 Alarm.
1.3.6.1.4.1.935.0.34
envSecurity3
NOTIFICATION-TYPE
WARNING: Security3 Alarm.
1.3.6.1.4.1.935.0.35
envSecurity4
NOTIFICATION-TYPE
WARNING: Security4 Alarm.
1.3.6.1.4.1.935.0.36
envSecurity5
NOTIFICATION-TYPE
WARNING: Security5 Alarm.
1.3.6.1.4.1.935.0.37
envSecurity6
NOTIFICATION-TYPE
WARNING: Security6 Alarm.
1.3.6.1.4.1.935.0.38
envSecurity7
NOTIFICATION-TYPE
WARNING: Security7 Alarm.
1.3.6.1.4.1.935.0.39
upsRecroterror
NOTIFICATION-TYPE
WARNING: Rectifier Rotation Error
1.3.6.1.4.1.935.0.47
upsBypassFreFail
NOTIFICATION-TYPE
WARNING: Bypass Frequency Fail
1.3.6.1.4.1.935.0.48
upsBypassacnormal
NOTIFICATION-TYPE
WARNING: Bypass AC Normal
1.3.6.1.4.1.935.0.49
upsBypassacabnormal
NOTIFICATION-TYPE
WARNING: Bypass AC Abnormal
1.3.6.1.4.1.935.0.50
upsTest
NOTIFICATION-TYPE
WARNING: UPS Test
1.3.6.1.4.1.935.0.51
upsScheduleShutdown
NOTIFICATION-TYPE
WARNING: UPS Schedule Shutdown
1.3.6.1.4.1.935.0.52
upsBypassReturn
NOTIFICATION-TYPE
The UPS return from Bypass Mode
1.3.6.1.4.1.935.0.53
upsShortCircuitShutdown
NOTIFICATION-TYPE
The UPS Short Circuit Shutdown
1.3.6.1.4.1.935.0.54
upsInverterOutputFailShutdown
NOTIFICATION-TYPE
The UPS Inverter Output Fail Shutdown
1.3.6.1.4.1.935.0.55
upsBypassBreadkerOnShutdown
NOTIFICATION-TYPE
The UPS Manual Bypass Breaker on Shutdown
1.3.6.1.4.1.935.0.56
upsHighDCShutdown
NOTIFICATION-TYPE
The UPS High DC Shutdown
1.3.6.1.4.1.935.0.57
upsEmergencyStop
NOTIFICATION-TYPE
The UPS Emergency Stop
1.3.6.1.4.1.935.0.58
upsInverterMode
NOTIFICATION-TYPE
The UPS Static Switch in Inverter Mode
1.3.6.1.4.1.935.0.59
upsBypassMode
NOTIFICATION-TYPE
The UPS Static Switch in Bypass Mode
1.3.6.1.4.1.935.0.60
upsOverTemperatureShutdown
NOTIFICATION-TYPE
The UPS Over Temperature Shutdown
1.3.6.1.4.1.935.0.61
upsOverLoadShutdown
NOTIFICATION-TYPE
The UPS Overload Shutdown
1.3.6.1.4.1.935.0.62
upsCapacityUnderrun
NOTIFICATION-TYPE
The UPS Capacity Underrun
1.3.6.1.4.1.935.0.63
upsCapacityNormal
NOTIFICATION-TYPE
The UPS Capacity Normal
1.3.6.1.4.1.935.0.64
upsLowBatteryShutdown
NOTIFICATION-TYPE
The UPS Low Battery Shutdown
1.3.6.1.4.1.935.0.67
buckOn
NOTIFICATION-TYPE
WARNING: The UPS has enabled Buck.
1.3.6.1.4.1.935.0.68
returnFromBuck
NOTIFICATION-TYPE
WARNING: The UPS has return from Buck.
1.3.6.1.4.1.935.0.69
returnFromBoost
NOTIFICATION-TYPE
WARNING: The UPS has return from Boost.
1.3.6.1.4.1.935.0.70