MIBs Depot

CM-PROTECTION-MIB

Registered at
1.3.6.1.4.1.2544.1.12.7
Last updated
2010-06-23 00:00
Organization
ADVA Optical Networking
Revisions
2010-06-23 00:00
Namespace
adva
Source file
CM-PROTECTION-MIB
Digest
sha256:f94374634f704092dc197c9028cea28da49bdc5b60a1ae18e995665df3258d41

Description

This module defines the Protection MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA Optical Networking.

Contact

Raghav Trivedi ADVA Optical Networking, Inc. Tel: +1 972 759-1239 E-mail: rtrivedi@advaoptical.com Postal: 2301 N. Greenville Ave. #300 Richardson, TX USA 75082

Imports

FromSymbols
ADVA-MIBfsp150cm
CM-ENTITY-MIBneIndex, shelfIndex, slotIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, StorageType, TEXTUAL-CONVENTION, TruthValue, VariablePointer

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ADVA-MIB
CM-COMMON-MIB
CM-ENTITY-MIB
CM-PROTECTION-MIB
CM-SYSTEM-MIB
ENTITY-MIB
IANA-ADDRESS-FAMILY-NUMBERS-MIB
IANA-ENTITY-MIB
IANAifType-MIB
IF-MIB
IPV6-TC
LLDP-V2-MIB
LLDP-V2-TC-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMP-TARGET-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
CmProtGroupStatus
TEXTUAL-CONVENTION
Enumerations for Protection Status. nooutstandingreq - No oustanding request, sf-protect - Signal failure on protect, sf-working - Signal failure on working, sd-protect - Signal degrade on protect, sd-working - Signal degrade on working, manual-protect - Manual on protect manual-working - Manual on working forced-working - Forced on working forced-protect - Forced on protect lockout-protect - Lockout on protect waitToRestore - Wait to restore
current
CmProtSwitchAction
TEXTUAL-CONVENTION
Enumerations for User initiated Protection Switch Action. manualfromworking - Manual Switch from Working, forcedfromworking - Forced Switch from Working, manualfromprotect - Manual Switch from Protect, forcedfromprotect - Forced Switch from Protect, lockoutfromprotect - Lockout from Protect
current
CmProtSwitchDirection
TEXTUAL-CONVENTION
Enumerations for Protection Switch Direction. unidirectional - Unidirectional Protection Switching, bidirectional - Bidirectional Protection Switching.
current
CmProtSwitchMode
TEXTUAL-CONVENTION
Enumerations for Protection Switch Mode. oneplusone - 1+1, this is the NPCUP mode, dualactiverx - In this mode, traffic is bridged in A2N direction (same as 1+1), however both network ports receive customer traffic in N2A direction. In this mode, both network ports are working, i.e. there is no protection. universalring - In this mode, traffic is bridged in A2N direction (same as 1+1), both network ports receive customer traffic in N2A direction. In this mode, both network ports are working, i.e. no protection. The main difference w.r.t dualactiverx is that traffic in N2A direction, which does not match the service definition is steered to the other network port, i.e. non-service matching traffic from N1 goes to N2 and vice versa.
current
CmProtUnitState
TEXTUAL-CONVENTION
Enumerations for Protection Unit State. active - Active Protection Unit, standby - Standby Protection Unit.
current
CmProtUnitType
TEXTUAL-CONVENTION
Enumerations for Protection Unit Type. working - Working Protection Unit, protect - Protect Protection Unit.
current

Objects

NameOIDSyntaxAccessStatus
cmProtObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2544.1.12.7.1
cmFacProtGroupTable
OBJECT-TYPE
A list of entries corresponding to the Facility Protection Groups. Entries can be created/deleted in this table by management application action.
1.3.6.1.4.1.2544.1.12.7.1.1not-accessiblecurrent
cmFacProtGroupEntry
OBJECT-TYPE
An entry containing information applicable to a particular Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1not-accessiblecurrent
cmFacProtGroupIndex
OBJECT-TYPE
Unique index value associated with the Facility Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.1Integer32read-onlycurrent
cmFacProtGroupUserLabel
OBJECT-TYPE
User Label associated with the Facility Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.2DisplayString (SIZE(0..64))read-createcurrent
cmFacProtGroupSwitchMode
OBJECT-TYPE
Facility Protection Group's Protection Switch Mode.
1.3.6.1.4.1.2544.1.12.7.1.1.1.3CmProtSwitchModeread-createcurrent
cmFacProtGroupRevertive
OBJECT-TYPE
Whether the Facility Protection is revertive or not. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.1.1.4TruthValueread-createcurrent
cmFacProtGroupWaitToRestore
OBJECT-TYPE
Time in minutes to wait before reverting to Working facility in case of cmFacProtGroupRevertive set to revertive. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.1.1.5Integer32 (1..60 | 0)read-createcurrent
cmFacProtGroupDirection
OBJECT-TYPE
Supported Protection Group Switch direction. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.1.1.6CmProtSwitchDirectionread-createcurrent
cmFacProtGroupWorkPort
OBJECT-TYPE
Facility Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port.
1.3.6.1.4.1.2544.1.12.7.1.1.1.7VariablePointerread-createcurrent
cmFacProtGroupProtPort
OBJECT-TYPE
This object represents the PROTECT facility Network Element Port when cmFacProtGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the second active port.
1.3.6.1.4.1.2544.1.12.7.1.1.1.8VariablePointerread-createcurrent
cmFacProtGroupStatus
OBJECT-TYPE
This object represents the PROTECTION group status.
1.3.6.1.4.1.2544.1.12.7.1.1.1.9CmProtGroupStatusread-onlycurrent
cmFacProtGroupAction
OBJECT-TYPE
User initiated protection switch action.
1.3.6.1.4.1.2544.1.12.7.1.1.1.10CmProtSwitchActionread-writecurrent
cmFacProtGroupStorageType
OBJECT-TYPE
The type of storage configured for this entry.
1.3.6.1.4.1.2544.1.12.7.1.1.1.11StorageTyperead-createcurrent
cmFacProtGroupRowStatus
OBJECT-TYPE
The status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of cmFacProtGroupRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with cmFacProtGroupRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The cmFacProtGroupRowStatus object may be modified if the associated instance of this object is equal to active(1).
1.3.6.1.4.1.2544.1.12.7.1.1.1.12RowStatusread-createcurrent
cmFacProtGroupMacAddress
OBJECT-TYPE
This object allows retrieval of the Mac Address of the PROTECTION group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.13MacAddressread-onlycurrent
cmFacProtUnitTable
OBJECT-TYPE
A list of entries corresponding to the Facility Protection Units.
1.3.6.1.4.1.2544.1.12.7.1.2not-accessiblecurrent
cmFacProtUnitEntry
OBJECT-TYPE
An entry containing information applicable to a particular Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.2.1not-accessiblecurrent
cmFacProtUnitIndex
OBJECT-TYPE
Unique index value associated with the Facility Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.2.1.1Integer32read-onlycurrent
cmFacProtUnitType
OBJECT-TYPE
Facility Protection Unit's Type, i.e. whether working or protect.
1.3.6.1.4.1.2544.1.12.7.1.2.1.2CmProtUnitTyperead-onlycurrent
cmFacProtUnitState
OBJECT-TYPE
Facility Protection Unit's State, i.e. whether active or standby.
1.3.6.1.4.1.2544.1.12.7.1.2.1.3CmProtUnitStateread-onlycurrent
cmFacProtUnitPort
OBJECT-TYPE
Facility Protection Unit's points to a facility (port). This object represents the facility Network Element port.
1.3.6.1.4.1.2544.1.12.7.1.2.1.4VariablePointerread-onlycurrent
cmMSPGroupTable
OBJECT-TYPE
A list of entries corresponding to the Multiplex Section Protection Groups. Entries can be created/deleted in this table by management application action.
1.3.6.1.4.1.2544.1.12.7.1.3not-accessiblecurrent
cmMSPGroupEntry
OBJECT-TYPE
An entry containing information applicable to a particular Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1not-accessiblecurrent
cmMSPGroupIndex
OBJECT-TYPE
Unique index value associated with the Multiplex Section Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.1Integer32read-onlycurrent
cmMSPGroupUserLabel
OBJECT-TYPE
User Label associated with the Multiplex Section Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.2DisplayString (SIZE(0..64))read-createcurrent
cmMSPGroupSwitchMode
OBJECT-TYPE
Multiplex Section Protection Group's Protection Switch Mode.
1.3.6.1.4.1.2544.1.12.7.1.3.1.3CmProtSwitchModeread-createcurrent
cmMSPGroupRevertive
OBJECT-TYPE
Whether the Multiplex Section Protection is revertive or not. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.3.1.4TruthValueread-createcurrent
cmMSPGroupWaitToRestore
OBJECT-TYPE
Time in minutes to wait before reverting to Working facility in case of cmMSPGroupRevertive set to revertive. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.3.1.5Integer32 (1..60 | 0)read-createcurrent
cmMSPGroupB2DEGTrigger
OBJECT-TYPE
B2DEG is trigger of MSP or not.
1.3.6.1.4.1.2544.1.12.7.1.3.1.6TruthValueread-createcurrent
cmMSPGroupDirection
OBJECT-TYPE
Supported Protection Group Switch direction. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.3.1.7CmProtSwitchDirectionread-createcurrent
cmMSPGroupWorkPort
OBJECT-TYPE
Multiplex Section Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port.
1.3.6.1.4.1.2544.1.12.7.1.3.1.8VariablePointerread-createcurrent
cmMSPGroupProtPort
OBJECT-TYPE
This object represents the PROTECT facility Network Element Port when cmMSPGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the second active port.
1.3.6.1.4.1.2544.1.12.7.1.3.1.9VariablePointerread-createcurrent
cmMSPGroupStatus
OBJECT-TYPE
This object represents the PROTECTION group status.
1.3.6.1.4.1.2544.1.12.7.1.3.1.10CmProtGroupStatusread-onlycurrent
cmMSPGroupAction
OBJECT-TYPE
User initiated protection switch action.
1.3.6.1.4.1.2544.1.12.7.1.3.1.11CmProtSwitchActionread-writecurrent
cmMSPGroupStorageType
OBJECT-TYPE
The type of storage configured for this entry.
1.3.6.1.4.1.2544.1.12.7.1.3.1.12StorageTyperead-createcurrent
cmMSPGroupRowStatus
OBJECT-TYPE
The status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of cmMSPGroupRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with cmMSPGroupRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The cmMSPGroupRowStatus object may be modified if the associated instance of this object is equal to active(1).
1.3.6.1.4.1.2544.1.12.7.1.3.1.13RowStatusread-createcurrent
cmMSPGroupMacAddress
OBJECT-TYPE
This object allows retrieval of the Mac Address of the PROTECTION group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.14MacAddressread-onlycurrent
cmMSPUnitTable
OBJECT-TYPE
A list of entries corresponding to the Multiplex Section Protection Units.
1.3.6.1.4.1.2544.1.12.7.1.4not-accessiblecurrent
cmMSPUnitEntry
OBJECT-TYPE
An entry containing information applicable to a particular Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.4.1not-accessiblecurrent
cmMSPUnitIndex
OBJECT-TYPE
Unique index value associated with the Multiplex Section Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.4.1.1Integer32read-onlycurrent
cmMSPUnitType
OBJECT-TYPE
Multiplex Section Protection Unit's Type, i.e. whether working or protect.
1.3.6.1.4.1.2544.1.12.7.1.4.1.2CmProtUnitTyperead-onlycurrent
cmMSPUnitState
OBJECT-TYPE
Multiplex Section Protection Unit's State, i.e. whether active or standby.
1.3.6.1.4.1.2544.1.12.7.1.4.1.3CmProtUnitStateread-onlycurrent
cmMSPUnitPort
OBJECT-TYPE
Facility Protection Unit's points to a facility (port). This object represents the facility Network Element port.
1.3.6.1.4.1.2544.1.12.7.1.4.1.4VariablePointerread-onlycurrent
cmProtNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2544.1.12.7.2
cmProtConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2544.1.12.7.3
cmProtCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2544.1.12.7.3.1
cmProtGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2544.1.12.7.3.2

Conformance

NameOIDStatus
cmProtCompliance
MODULE-COMPLIANCE
Describes the requirements for conformance to the CM Prot group.
1.3.6.1.4.1.2544.1.12.7.3.1.1current
cmProtObjectGroup
OBJECT-GROUP
A collection of objects used to manage the Protection Object group.
1.3.6.1.4.1.2544.1.12.7.3.2.1current
cmMSProtObjectGroup
OBJECT-GROUP
A collection of objects used to manage the Multiplex Section Protection Object group.
1.3.6.1.4.1.2544.1.12.7.3.2.2current