CISCO-SWITCH-NETFLOW-MIB
- Registered at
- 1.3.6.1.4.1.9.9.737
- Last updated
- 2010-05-26 00:00
- Organization
- Cisco Systems, Inc.
- Revisions
- 2010-05-26 00:00
- Namespace
- cisco
- Source file
CISCO-SWITCH-NETFLOW-MIB- Digest
sha256:8bbc947128261815d274cf7a9d384c48872a6085f09b14b9374984b13425db7c
Description
This MIB module defines management objects for the Netflow features on Cisco Layer 2 and Layer 3 devices.
Contact
Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-lan-switch-snmp@cisco.com
Imports
| From | Symbols |
|---|---|
| CISCO-QOS-PIB-MIB | Percent |
| CISCO-SMI | ciscoMgmt |
| ENTITY-MIB | entPhysicalDescr, entPhysicalIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CISCO-QOS-PIB-MIB CISCO-SMI CISCO-SWITCH-NETFLOW-MIB ENTITY-MIB IANA-ENTITY-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| CsnNetflowDirectionTypes TEXTUAL-CONVENTION Defines the various Netflow direction types. 'none' - no Netflow direction is supported. 'ingress' - Netflow direction is ingress. 'egress' - Netflow direction is egress. 'ingressAndEgress' - Netflow direction is both ingress and egress. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ciscoSwitchNetflowMIBNotifs OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.0 | |||
| ciscoSwitchNetflowMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1 | |||
| csnAccounting OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1 | |||
| csnAccGlobal OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.1 | |||
| csnNetflowDirectionType OBJECT-TYPE This object specifies the direction type of Netflow enabled on this system. | 1.3.6.1.4.1.9.9.737.1.1.1.1 | CsnNetflowDirectionTypes | read-write | current |
| csnAccNotifControl OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.2 | |||
| csnUsageThreshExceedNotifEnable OBJECT-TYPE This object specifies whether the system produces the csnUsageThreshExceededNotif. A 'false' value will prevent csnUsageThreshExceededNotif notifications from being generated by this system. | 1.3.6.1.4.1.9.9.737.1.1.2.1 | TruthValue | read-write | current |
| cshAccUsageThresh OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.3 | |||
| csnUsageThreshTable OBJECT-TYPE A table containing Netflow table usage monitoring configuration information. | 1.3.6.1.4.1.9.9.737.1.1.3.1 | not-accessible | current | |
| csnUsageThreshEntry OBJECT-TYPE A conceptual row of csnUsageThreshTable, containing the Netflow table usage monitoring configuration information. | 1.3.6.1.4.1.9.9.737.1.1.3.1.1 | not-accessible | current | |
| csnUsageDirection OBJECT-TYPE This object specifies the direction of Netflow on the system. | 1.3.6.1.4.1.9.9.737.1.1.3.1.1.1 | CsnNetflowDirectionTypes | not-accessible | current |
| csnUsageThreshold OBJECT-TYPE This object specifies the Netflow table usage threshold in percentage value. When the value of this object is set to zero, Netflow table usage monitoring is disabled. When the value of this object is set to greater than zero, Netflow table usage monitoring is enabled. | 1.3.6.1.4.1.9.9.737.1.1.3.1.1.2 | Percent | read-write | current |
| csnUsageInterval OBJECT-TYPE This object specifies the interval in seconds over which the Netflow table usage (the value of csnUtilization) will be compared against the threshold specified by csnUsageThreshold. | 1.3.6.1.4.1.9.9.737.1.1.3.1.1.3 | Unsigned32 (1..4294967295) | read-write | current |
| csnAccUtilization OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.4 | |||
| csnUtilizationTable OBJECT-TYPE A table containing Netflow table utilization information of each switching engine and a Newflow direction type. | 1.3.6.1.4.1.9.9.737.1.1.4.1 | not-accessible | current | |
| csnUtilizationEntry OBJECT-TYPE A conceptual row of csnUtilizationTable, containing the Netflow table utilization information for a particular switching engine and a particular Netflow type. | 1.3.6.1.4.1.9.9.737.1.1.4.1.1 | not-accessible | current | |
| csnUtilization OBJECT-TYPE This object indicates the percentage of Netflow table utilization. | 1.3.6.1.4.1.9.9.737.1.1.4.1.1.1 | Percent | read-only | current |
| csnAccNetflowTableSize OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.5 | |||
| csnNetflowTableSizeTable OBJECT-TYPE A table containing Netflow table size information of each Netflow type supported in the system. | 1.3.6.1.4.1.9.9.737.1.1.5.1 | not-accessible | current | |
| csnNetflowTableSizeEntry OBJECT-TYPE A conceptual row of csnNetflowTableSizeTable, containing the Netflow table size information for a particular Netflow type. | 1.3.6.1.4.1.9.9.737.1.1.5.1.1 | not-accessible | current | |
| csnNetflowTableTotalEntries OBJECT-TYPE This object indicates the total number of entries in the Netflow table for a particular Netflow direction type. | 1.3.6.1.4.1.9.9.737.1.1.5.1.1.1 | Unsigned32 | read-only | current |
| csnAccSampler OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.1.1.6 | |||
| csnSamplerTotal OBJECT-TYPE This object indicates the total number of Netflow samplers in the device. | 1.3.6.1.4.1.9.9.737.1.1.6.1 | Unsigned32 | read-only | current |
| csnSamplerAvailable OBJECT-TYPE This object indicates the number of Netflow samplers available in the system. | 1.3.6.1.4.1.9.9.737.1.1.6.2 | Unsigned32 | read-only | current |
| ciscoSwitchNetflowMIBConform OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.2 | |||
| csnMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.2.1 | |||
| csnMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.737.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| csnUsageThreshExceededNotif NOTIFICATION-TYPE A csnUsageThreshExceededNotif is sent if the Netflow table usage has exceeded the configured threshold specified by csnUsageThreshold. | 1.3.6.1.4.1.9.9.737.0.1 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| csnMIBCompliance MODULE-COMPLIANCE The compliance statement for CISCO-SWITCH-NETFLOW-MIB. | 1.3.6.1.4.1.9.9.737.2.1.1 | current |
| csnGlobalGroup OBJECT-GROUP A collection of objects providing global Netflow type configuration. | 1.3.6.1.4.1.9.9.737.2.2.1 | current |
| csnUsageThreshNotifControlGroup OBJECT-GROUP A collection of objects providing enabling/disabling of the Netflow table usage threshold notifications. | 1.3.6.1.4.1.9.9.737.2.2.2 | current |
| csnUsageThreshGroup OBJECT-GROUP A collection of objects providing Netflow table usage threshold information and configuration. | 1.3.6.1.4.1.9.9.737.2.2.3 | current |
| csnUtilizationGroup OBJECT-GROUP A collection of objects providing Netflow utilization information. | 1.3.6.1.4.1.9.9.737.2.2.4 | current |
| csnUsageThreshNotifGroup NOTIFICATION-GROUP A collection of notifications providing Netflow table usage threshold exceeded notification. | 1.3.6.1.4.1.9.9.737.2.2.5 | current |
| csnNetflowTableSizeGroup OBJECT-GROUP A collection of objects providing Netflow table size information. | 1.3.6.1.4.1.9.9.737.2.2.6 | current |
| csnSamplerGroup OBJECT-GROUP A collection of objects providing Netflow sampler information. | 1.3.6.1.4.1.9.9.737.2.2.7 | current |