APRISAXE-MIB-4RF
- Registered at
- 1.3.6.1.4.1.14817.2.51.3.6.1.4.1.14817.7.3.1
- Last updated
- 2007-04-30 00:00
- Organization
- www.4rf.com
- Revisions
- 2007-04-30 00:00, 2004-12-09 03:04
- Namespace
- 4rf
- Source file
APRISAXE-MIB-4RF- Digest
sha256:c2bcf73296188f5a2b2008225aae3bfa287b6aaca1906f3f50d1abd3aed39e89
Description
MIB for the AprisaXE project
Contact
postal: 4RF Communications Ltd 26 Glover Street Ngauranga PO Box 13-506 Wellington 6032 New Zealand phone: +64 4 499 6000 email: support@4rf.com
Imports
| From | Symbols |
|---|---|
| APRISAXE-TC-4RF | AprisaXE2WireSignalState, AprisaXE4WInputLevel, AprisaXE4WOutputLevel, AprisaXE4WRxGain, AprisaXE4WTxGain, AprisaXEAdcVoltage, AprisaXEAdpcmCompression, AprisaXEAlarmMapping, AprisaXEAlarmOutput, AprisaXEAlarmPolarity, AprisaXEAlarmSource, AprisaXEAlarmType, AprisaXECCActivationStatus, AprisaXECardType, AprisaXEChannelControlType, AprisaXEConnectionID, AprisaXEDataStatus, AprisaXEDbValue, AprisaXEDefaultAction, AprisaXEEthernetFrameRate, AprisaXEEthernetGroup, AprisaXEEthernetGrouping, AprisaXEEthernetPortNumber, AprisaXEEthernetPortPriority, AprisaXEEthernetPrioQueueMapping, AprisaXEEthernetPrioQueueScheduling, AprisaXEFXOCountry, AprisaXEFXOInputLevel, AprisaXEFXOOutputLevel, AprisaXEFXSInputLevel, AprisaXEFXSOutputLevel, AprisaXEFXSPMLevel, AprisaXEFXSPathMute, AprisaXEHardwareVersion, AprisaXEHssSerialMode, AprisaXEIQData, AprisaXEInterfaceCnxnType, AprisaXEPSCActiveRadio, AprisaXEPSCActiveTx, AprisaXEPcmLaw, AprisaXEPcmMode, AprisaXEPortNumber, AprisaXEQuadJetConnectionType, AprisaXEQuadJetLineEncoding, AprisaXEQuadJetLoopbacks, AprisaXEQuadJetMultiframeEnable, AprisaXEQuadJetTrafficType, AprisaXEQuadJetWaveFormShapers, AprisaXESerialEquipmentMode, AprisaXESignalState, AprisaXESlotNumber, AprisaXETdmBus, AprisaXETdmPortType |
| COMMON-TC-4RF | FourRFAlarmEnabled, FourRFAlarmPresent, FourRFAlarmSeverity, FourRFAlarmStatus, FourRFChannelWidth, FourRFClockSource, FourRFErrorCounter, FourRFFanStatus, FourRFFrequency, FourRFHardwareVersion, FourRFImageVersion, FourRFLoopback, FourRFMHSBCommand, FourRFMHSBStatus, FourRFModulationType, FourRFNetworkClockSelect, FourRFNetworkClockStatus, FourRFProcessResultType, FourRFRSSI, FourRFRfBand, FourRFSNR, FourRFSerialNumber, FourRFTemperature, FourRFTxPower |
| MIB-4RF | fourRFModules |
| PRODUCTS-MIB-4RF | fourRFAprisaXE |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
APRISAXE-MIB-4RF APRISAXE-TC-4RF COMMON-TC-4RF MIB-4RF PRODUCTS-MIB-4RF SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.14817.7.3.1.2 | aprisaXEObjects | |
| 1.3.6.1.4.1.14817.7.3.1.3 | aprisaXEEvents |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| aprisaXEConfig OBJECT-IDENTITY The root of the OID sub-tree for the AprisaXE product configuration. | 1.3.6.1.4.1.14817.7.3.1 | current | ||
| aprisaXEGroups OBJECT-IDENTITY The root of the OID sub-tree for the AprisaXE object groups. | 1.3.6.1.4.1.14817.7.3.1.1 | current | ||
| aprisaXEObjects OBJECT-IDENTITY The root of the OID sub-tree for the AprisaXE product objects. | 1.3.6.1.4.1.14817.7.3.1.2 | current | ||
| aprisaXETerminal OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.1 | |||
| aprisaXETerminalRfChannelWidth OBJECT-TYPE The terminal RF channel width, the options are: 20kHz, 25kHz, 50kHz, 75kHz, 100kHz, 125kHz, 150kHz, 200kHz, 250kHz, 400kHz, 500kHz, 800kHz, 1MHz, 1.25MHz, 1.75MHz, 2MHz, 3.5MHz, 7MHz | 1.3.6.1.4.1.14817.7.3.1.2.1.4 | FourRFChannelWidth | read-write | current |
| aprisaXETerminalRSSI OBJECT-TYPE The terminal RSSI in dBm. | 1.3.6.1.4.1.14817.7.3.1.2.1.5 | FourRFRSSI | read-only | current |
| aprisaXETerminalModulationState OBJECT-TYPE The terminal modulation state. | 1.3.6.1.4.1.14817.7.3.1.2.1.6 | FourRFModulationType | read-write | current |
| aprisaXETerminalClockReference OBJECT-TYPE The terminal clock reference configuration: automatic - manual - | 1.3.6.1.4.1.14817.7.3.1.2.1.7 | INTEGER {automatic(0), manual(1)} | read-write | current |
| aprisaXETerminalClockSource OBJECT-TYPE The terminal clock source configuration: network - clocking is recovered from the synchronous network to which the terminal is connected. link - clocking is recovered from the remote end of the link. internal - the clock is generated internally. The clock reference must be in manual mode for this to take effect. | 1.3.6.1.4.1.14817.7.3.1.2.1.8 | FourRFClockSource | read-write | current |
| aprisaXETerminalAlarmStatus OBJECT-TYPE The terminal alarm status, this reflects the overall status of the terminal. This will match the colour of the front panel control LED. The states used are noAlarm, minorAlarm and majorAlarm. | 1.3.6.1.4.1.14817.7.3.1.2.1.9 | FourRFAlarmStatus | read-only | current |
| aprisaXETerminalRxAlarmStatus OBJECT-TYPE The terminal alarm status, this reflects the overall RX status of the terminal. This will match the colour of the front panel RX LED. The states used are noAlarm, minorAlarm and majorAlarm. | 1.3.6.1.4.1.14817.7.3.1.2.1.10 | FourRFAlarmStatus | read-only | current |
| aprisaXETerminalTxAlarmStatus OBJECT-TYPE The terminal alarm status, this reflects the overall TX status of the terminal. This will match the colour of the front panel TX LED. The states used are noAlarm, minorAlarm and majorAlarm. | 1.3.6.1.4.1.14817.7.3.1.2.1.11 | FourRFAlarmStatus | read-only | current |
| aprisaXETerminalBandwidth OBJECT-TYPE This returns the total bandwidth available over the link in kbps. | 1.3.6.1.4.1.14817.7.3.1.2.1.12 | Unsigned32 | read-only | current |
| aprisaXEMotherboardSerialNumber OBJECT-TYPE The unique serial number for the motherboard. | 1.3.6.1.4.1.14817.7.3.1.2.1.13 | FourRFSerialNumber | read-only | current |
| aprisaXETerminalAllocatedBandwidth OBJECT-TYPE This returns the total bandwidth allocated over the link in kbps. | 1.3.6.1.4.1.14817.7.3.1.2.1.14 | Unsigned32 | read-only | current |
| aprisaXETerminalLoopbackBandwidth OBJECT-TYPE This returns the total loopback bandwidth allocated in kbps. | 1.3.6.1.4.1.14817.7.3.1.2.1.15 | Unsigned32 | read-only | current |
| aprisaXETerminalNetworkClockPrimaryStatus OBJECT-TYPE This returns the status of the network clock primary source. | 1.3.6.1.4.1.14817.7.3.1.2.1.16 | FourRFNetworkClockStatus | read-only | current |
| aprisaXETerminalNetworkClockSecondaryStatus OBJECT-TYPE This returns the status of the network clock secondary source. | 1.3.6.1.4.1.14817.7.3.1.2.1.17 | FourRFNetworkClockStatus | read-only | current |
| aprisaXETerminalNetworkClockCommand OBJECT-TYPE Forces a change in the active network clock. | 1.3.6.1.4.1.14817.7.3.1.2.1.18 | INTEGER {none(0), makePrimaryActive(1), makeSecondaryActive(2)} | read-write | current |
| aprisaXETerminalStartupComplete OBJECT-TYPE Indicates whether the terminal startup sequence is complete. | 1.3.6.1.4.1.14817.7.3.1.2.1.19 | INTEGER {notComplete(0), startupComplete(1)} | read-only | current |
| aprisaXETerminalImageAlarmClear OBJECT-TYPE Indicates whether the terminal startup sequence is complete. | 1.3.6.1.4.1.14817.7.3.1.2.1.20 | INTEGER {noCommand(0), clearAlternateImageAlarm(1), clearDefaultImageAlarm(2)} | read-write | current |
| aprisaXETerminalMuxStatus OBJECT-TYPE This indicates if the terminal is operating in Mux mode. | 1.3.6.1.4.1.14817.7.3.1.2.1.21 | INTEGER {none(0), muxOnly(1)} | read-only | obsolete |
| aprisaXETerminalBootloaderDataVersion OBJECT-TYPE This indicates the data version of the shared data field in the bootloader. | 1.3.6.1.4.1.14817.7.3.1.2.1.22 | Unsigned32 | read-only | current |
| aprisaXETerminalUploadFailAlarmClear OBJECT-TYPE Used to clear a current Upload Failure Alarm. | 1.3.6.1.4.1.14817.7.3.1.2.1.23 | INTEGER {noCommand(0), clearUploadFailAlarm(1)} | read-write | current |
| aprisaXETerminalEquipmentType OBJECT-TYPE This indicates what type of equipment the terminal is. | 1.3.6.1.4.1.14817.7.3.1.2.1.24 | INTEGER {axeUnknown(0), axeRadio(1), axeMux(2), axeProtSwitch(3), axeProtRadio(4)} | read-only | current |
| aprisaXEPerformance OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.6 | |||
| aprisaXECorrectableErrorCount OBJECT-TYPE The terminal correctable error count. | 1.3.6.1.4.1.14817.7.3.1.2.6.1 | FourRFErrorCounter | read-only | current |
| aprisaXEUncorrectableErrorCount OBJECT-TYPE The terminal uncorrectable error count. | 1.3.6.1.4.1.14817.7.3.1.2.6.2 | FourRFErrorCounter | read-only | current |
| aprisaXEModemSNR OBJECT-TYPE The modem signal to noise ratio. | 1.3.6.1.4.1.14817.7.3.1.2.6.3 | FourRFSNR | read-only | current |
| aprisaXETxPacketCount OBJECT-TYPE The terminal transmitted ethernet packet count (to link). | 1.3.6.1.4.1.14817.7.3.1.2.6.4 | Counter32 | read-only | current |
| aprisaXERxPacketCount OBJECT-TYPE The terminal received ethernet packet count (from link). | 1.3.6.1.4.1.14817.7.3.1.2.6.5 | Counter32 | read-only | current |
| aprisaXERxPacketErrorCount OBJECT-TYPE The terminal received ethernet packet error count (from link). | 1.3.6.1.4.1.14817.7.3.1.2.6.6 | Counter32 | read-only | current |
| aprisaXEErrorCounterCommand OBJECT-TYPE Forces reset, freeze or unfreeze the error counters. | 1.3.6.1.4.1.14817.7.3.1.2.6.7 | INTEGER {countersRunning(0), resetCounters(1), freezeCounters(2), unfreezeCounters(3)} | read-write | current |
| aprisaXEErrorFreeSeconds OBJECT-TYPE The number of Error Free Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.8 | Counter32 | read-only | current |
| aprisaXEErroredSeconds OBJECT-TYPE The number of Errored Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.9 | Counter32 | read-only | current |
| aprisaXEBERExponent OBJECT-TYPE The exponent of the Bit Error Rate for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.10 | DisplayString (SIZE(0..64)) | read-only | current |
| aprisaXEPscSysUncorrectableErrorCount OBJECT-TYPE The terminal uncorrectable error count. | 1.3.6.1.4.1.14817.7.3.1.2.6.11 | DisplayString (SIZE(0..64)) | read-only | current |
| aprisaXEPscSysErrorFreeSeconds OBJECT-TYPE The number of Error Free Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.12 | Counter32 | read-only | current |
| aprisaXEPscSysErroredSeconds OBJECT-TYPE The number of Errored Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.13 | Counter32 | read-only | current |
| aprisaXEPscSysBERExponent OBJECT-TYPE The exponent of the Bit Error Rate for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.14 | DisplayString (SIZE(0..64)) | read-only | current |
| aprisaXEPscRadioAUncorrectableErrorCount OBJECT-TYPE The terminal uncorrectable error count. | 1.3.6.1.4.1.14817.7.3.1.2.6.15 | FourRFErrorCounter | read-only | current |
| aprisaXEPscRadioAErrorFreeSeconds OBJECT-TYPE The number of Error Free Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.16 | Counter32 | read-only | current |
| aprisaXEPscRadioAErroredSeconds OBJECT-TYPE The number of Errored Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.17 | Counter32 | read-only | current |
| aprisaXEPscRadioABERExponent OBJECT-TYPE The exponent of the Bit Error Rate for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.18 | DisplayString (SIZE(0..64)) | read-only | current |
| aprisaXEPscRadioBUncorrectableErrorCount OBJECT-TYPE The terminal uncorrectable error count. | 1.3.6.1.4.1.14817.7.3.1.2.6.19 | FourRFErrorCounter | read-only | current |
| aprisaXEPscRadioBErrorFreeSeconds OBJECT-TYPE The number of Error Free Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.20 | Counter32 | read-only | current |
| aprisaXEPscRadioBErroredSeconds OBJECT-TYPE The number of Errored Seconds for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.21 | Counter32 | read-only | current |
| aprisaXEPscRadioBBERExponent OBJECT-TYPE The exponent of the Bit Error Rate for the terminal. | 1.3.6.1.4.1.14817.7.3.1.2.6.22 | DisplayString (SIZE(0..64)) | read-only | current |
| aprisaXEExternalAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11 | |||
| aprisaXEExternalAlarm1 OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.1 | |||
| aprisaXEExternalAlarm1Status OBJECT-TYPE The status of the first external alarm input. | 1.3.6.1.4.1.14817.7.3.1.2.11.1.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarm1Severity OBJECT-TYPE The severity of the first external alarm input. | 1.3.6.1.4.1.14817.7.3.1.2.11.1.2 | FourRFAlarmSeverity | read-write | current |
| aprisaXEExternalAlarm1Enabled OBJECT-TYPE Indicates whether the first external alarm input is enabled. If not changes to the input will be ignored. By default the alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.11.1.3 | FourRFAlarmEnabled | read-write | current |
| aprisaXEExternalAlarm1Mapping OBJECT-TYPE This defines how the first external alarm input is mapped to the remote alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.1.4 | AprisaXEAlarmMapping | read-write | current |
| aprisaXEExternalAlarm1Description OBJECT-TYPE A description (user defined) for the external alarm. | 1.3.6.1.4.1.14817.7.3.1.2.11.1.5 | DisplayString (SIZE(0..64)) | read-write | current |
| aprisaXEExternalAlarm2 OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.2 | |||
| aprisaXEExternalAlarm2Status OBJECT-TYPE The status of the second external alarm input. | 1.3.6.1.4.1.14817.7.3.1.2.11.2.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarm2Severity OBJECT-TYPE The severity of the second external alarm input. | 1.3.6.1.4.1.14817.7.3.1.2.11.2.2 | FourRFAlarmSeverity | read-write | current |
| aprisaXEExternalAlarm2Enabled OBJECT-TYPE Indicates whether the second external alarm input is enabled. If not changes to the input will be ignored. By default the alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.11.2.3 | FourRFAlarmEnabled | read-write | current |
| aprisaXEExternalAlarm2Mapping OBJECT-TYPE This defines how the second external alarm input is mapped to the remote alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.2.4 | AprisaXEAlarmMapping | read-write | current |
| aprisaXEExternalAlarm2Description OBJECT-TYPE A description (user defined) for the external alarm. | 1.3.6.1.4.1.14817.7.3.1.2.11.2.5 | DisplayString (SIZE(0..64)) | read-write | current |
| aprisaXEExternalAlarmPolarity OBJECT-TYPE Indicates the polarity used to indicate the presence of an alarm at an external alarm input. | 1.3.6.1.4.1.14817.7.3.1.2.11.3 | AprisaXEAlarmPolarity | read-write | current |
| aprisaXEExternalAlarmOutputPolarity OBJECT-TYPE Indicates the polarity used to indicate the presence of an alarm at an external alarm output, this may be different from the input polarity. | 1.3.6.1.4.1.14817.7.3.1.2.11.4 | INTEGER {polarityClosed(0), polarityOpen(1)} | read-write | current |
| aprisaXEExternalAlarmOutputOne OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.5 | |||
| aprisaXEExternalAlarmOutputOneStatus OBJECT-TYPE The status of the first external alarm output. | 1.3.6.1.4.1.14817.7.3.1.2.11.5.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarmOutputOneMapping OBJECT-TYPE This defines how the first external alarm output is mapped to the alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.5.2 | AprisaXEAlarmMapping | read-write | current |
| aprisaXEExternalAlarmOutputTwo OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.6 | |||
| aprisaXEExternalAlarmOutputTwoStatus OBJECT-TYPE The status of the second external alarm output. | 1.3.6.1.4.1.14817.7.3.1.2.11.6.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarmOutputTwoMapping OBJECT-TYPE This defines how the second external alarm output is mapped to the alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.6.2 | AprisaXEAlarmMapping | read-write | current |
| aprisaXEExternalAlarmOutputThree OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.7 | |||
| aprisaXEExternalAlarmOutputThreeStatus OBJECT-TYPE The status of the third external alarm output. | 1.3.6.1.4.1.14817.7.3.1.2.11.7.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarmOutputThreeMapping OBJECT-TYPE This defines how the third external alarm output is mapped to the alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.7.2 | AprisaXEAlarmMapping | read-write | current |
| aprisaXEExternalAlarmOutputFour OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.11.8 | |||
| aprisaXEExternalAlarmOutputFourStatus OBJECT-TYPE The status of the fourth external alarm output. | 1.3.6.1.4.1.14817.7.3.1.2.11.8.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEExternalAlarmOutputFourMapping OBJECT-TYPE This defines how the fourth external alarm output is mapped to the alarms. | 1.3.6.1.4.1.14817.7.3.1.2.11.8.2 | AprisaXEAlarmMapping | read-write | current |
| aprisaXERemoteAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.16 | |||
| aprisaXEMajorRemoteAlarmStatus OBJECT-TYPE The status of the remote major alarm. | 1.3.6.1.4.1.14817.7.3.1.2.16.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEMajorRemoteAlarmOutput OBJECT-TYPE This defines how the remote major alarm is mapped to the external alarm outputs. | 1.3.6.1.4.1.14817.7.3.1.2.16.2 | AprisaXEAlarmOutput | read-write | obsolete |
| aprisaXEMinorRemoteAlarmStatus OBJECT-TYPE The status of the remote minor alarm. | 1.3.6.1.4.1.14817.7.3.1.2.16.10 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEMinorRemoteAlarmOutput OBJECT-TYPE This defines how the remote minor alarm is mapped to the external alarm outputs. | 1.3.6.1.4.1.14817.7.3.1.2.16.11 | AprisaXEAlarmOutput | read-write | obsolete |
| aprisaXEMHSB OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.19 | |||
| aprisaXEMHSBStatus OBJECT-TYPE The state of an MHSB configured terminal. | 1.3.6.1.4.1.14817.7.3.1.2.19.1 | FourRFMHSBStatus | read-only | current |
| aprisaXEMHSBEnable OBJECT-TYPE Set the terminal into Monitored Hot Standby Mode. | 1.3.6.1.4.1.14817.7.3.1.2.19.2 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| aprisaXEMHSBCommand OBJECT-TYPE Commands to apply while in MHSB mode. | 1.3.6.1.4.1.14817.7.3.1.2.19.3 | FourRFMHSBCommand | read-write | current |
| aprisaXEMHSBTerminalSelect OBJECT-TYPE Configure terminal as terminal A or terminal B of an MHSB pair. | 1.3.6.1.4.1.14817.7.3.1.2.19.4 | INTEGER {none(0), terminalA(1), terminalB(2)} | read-write | current |
| aprisaXEMHSBSwitchoverStatus OBJECT-TYPE Status of the alarm reflecting if a switchover has occurred. | 1.3.6.1.4.1.14817.7.3.1.2.19.5 | FourRFAlarmStatus | read-only | current |
| aprisaXEFans OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.21 | |||
| aprisaXEFan1Status OBJECT-TYPE The status of the fan one. | 1.3.6.1.4.1.14817.7.3.1.2.21.1 | FourRFFanStatus | read-only | current |
| aprisaXEFan2Status OBJECT-TYPE The status of the fan two. | 1.3.6.1.4.1.14817.7.3.1.2.21.2 | FourRFFanStatus | read-only | current |
| aprisaXEFanEnable OBJECT-TYPE Turn the fans on or off. | 1.3.6.1.4.1.14817.7.3.1.2.21.3 | INTEGER {fansDisabled(0), fansEnabled(1)} | read-write | current |
| aprisaXEAlarmTable OBJECT-TYPE This table stores the currently active alarms. Up to 500 separate alarms will be stored in the table. | 1.3.6.1.4.1.14817.7.3.1.2.26 | not-accessible | current | |
| aprisaXEAlarmEntry OBJECT-TYPE The table entry index specification, just the alarm index. | 1.3.6.1.4.1.14817.7.3.1.2.26.1 | not-accessible | current | |
| aprisaXEAlarmIndex OBJECT-TYPE The index into the alarm table. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.1 | INTEGER (0..500) | read-only | current |
| aprisaXEAlarmSlot OBJECT-TYPE The number of the slot generating the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.2 | AprisaXESlotNumber | read-only | current |
| aprisaXEAlarmSource OBJECT-TYPE The source of the alarm, a card type or external. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.3 | AprisaXEAlarmSource | read-only | current |
| aprisaXEAlarmPort OBJECT-TYPE The source port of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.4 | AprisaXEPortNumber | read-only | current |
| aprisaXEAlarmSeverity OBJECT-TYPE The severity of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.5 | FourRFAlarmSeverity | read-only | current |
| aprisaXEAlarmType OBJECT-TYPE The type of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.6 | AprisaXEAlarmType | read-only | current |
| aprisaXEAlarmTime OBJECT-TYPE The time that the alarm occurred. | 1.3.6.1.4.1.14817.7.3.1.2.26.1.7 | DisplayString | read-only | current |
| aprisaXEAlarmHistoryTable OBJECT-TYPE This table stores a history of the alarms as they become active and cleared. | 1.3.6.1.4.1.14817.7.3.1.2.31 | not-accessible | current | |
| aprisaXEAlarmHistoryEntry OBJECT-TYPE The table entry index specification, just the alarm index. | 1.3.6.1.4.1.14817.7.3.1.2.31.1 | not-accessible | current | |
| aprisaXEAlarmHistoryIndex OBJECT-TYPE The index into the alarm history table. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.1 | INTEGER (0..100) | read-only | current |
| aprisaXEAlarmHistorySlot OBJECT-TYPE The number of the slot generating the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.2 | AprisaXESlotNumber | read-only | current |
| aprisaXEAlarmHistorySource OBJECT-TYPE The source of the alarm, a card type or external. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.3 | AprisaXEAlarmSource | read-only | current |
| aprisaXEAlarmHistoryPort OBJECT-TYPE The source port of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.4 | AprisaXEPortNumber | read-only | current |
| aprisaXEAlarmHistorySeverity OBJECT-TYPE The severity of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.5 | FourRFAlarmSeverity | read-only | current |
| aprisaXEAlarmHistoryType OBJECT-TYPE The type of the alarm. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.6 | AprisaXEAlarmType | read-only | current |
| aprisaXEAlarmHistoryPresent OBJECT-TYPE Indicates whether the alarm is present or not. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.7 | FourRFAlarmPresent | read-only | current |
| aprisaXEAlarmHistoryTime OBJECT-TYPE The time that the alarm state change occurred. | 1.3.6.1.4.1.14817.7.3.1.2.31.1.8 | DisplayString | read-only | current |
| aprisaXEAlarmControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.32 | |||
| aprisaXEAlarmHistoryCommand OBJECT-TYPE Allows the alarm history table to be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.32.1 | INTEGER {noCommand(0), clearHistory(1)} | read-write | current |
| aprisaXETransmitter OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.36 | |||
| aprisaXETransmitterStatus OBJECT-TYPE Indicates whether the transmitter is currently on or off. | 1.3.6.1.4.1.14817.7.3.1.2.36.1 | INTEGER {transmitterOff(0), transmitterOn(1)} | read-only | current |
| aprisaXETransmitterCommand OBJECT-TYPE Commands used to control the transmitter, currently the transmitter can be switched on and off. No other commands are defined. | 1.3.6.1.4.1.14817.7.3.1.2.36.2 | INTEGER {noCommand(0), transmitterOff(1), transmitterOn(2)} | read-write | current |
| aprisaXETransmitterSynthesiserStatus OBJECT-TYPE The status of the transmitter synthesiser. | 1.3.6.1.4.1.14817.7.3.1.2.36.3 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitter5VPowerStatus OBJECT-TYPE The status of the transmitter 5V power supply. | 1.3.6.1.4.1.14817.7.3.1.2.36.4 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitter11VPowerStatus OBJECT-TYPE The status of the transmitter 11V power supply. | 1.3.6.1.4.1.14817.7.3.1.2.36.5 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitter28VPowerStatus OBJECT-TYPE The status of the transmitter 28V power supply. | 1.3.6.1.4.1.14817.7.3.1.2.36.6 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitterFrequency OBJECT-TYPE The terminal transmit frequency in MHz. The possible bands are: 330 to 400 MHz (300 MHz) 400 to 470 MHz (400 MHz) 1350 to 1550 MHz (1400 MHz) The frequency value should be supplied in Hz. | 1.3.6.1.4.1.14817.7.3.1.2.36.7 | FourRFFrequency | read-write | current |
| aprisaXETransmitterPower OBJECT-TYPE The TX power value, the value should be entered in dB. | 1.3.6.1.4.1.14817.7.3.1.2.36.8 | FourRFTxPower | read-write | current |
| aprisaXETransmitterAGC OBJECT-TYPE The Automatic Gain Control value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.9 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitterForwardPower OBJECT-TYPE The forward power measurement value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.10 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitterReversePower OBJECT-TYPE The reverse power value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.11 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitterTemperature OBJECT-TYPE The temperature value in degrees Celcius. | 1.3.6.1.4.1.14817.7.3.1.2.36.12 | FourRFTemperature | read-only | obsolete |
| aprisaXETransmitterVTune OBJECT-TYPE The voltage output from TX synth. | 1.3.6.1.4.1.14817.7.3.1.2.36.13 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitter28VSupply OBJECT-TYPE The 28V supply rail value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.14 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitter11VSupply OBJECT-TYPE The 11V supply rail value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.15 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitter5VDigitalSupply OBJECT-TYPE The 5V digital supply rail value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.16 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitter7VSupply OBJECT-TYPE The 7V RF supply rail value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.17 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitter9VSupply OBJECT-TYPE The 9V supply synthesiser rail value in millivolts. | 1.3.6.1.4.1.14817.7.3.1.2.36.18 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXETransmitterCharacterisationDataStatus OBJECT-TYPE The status of the transmitter characterisation data. | 1.3.6.1.4.1.14817.7.3.1.2.36.19 | AprisaXEDataStatus | read-only | current |
| aprisaXETransmitterSerialNumber OBJECT-TYPE The unique module serial number for the transmitter. | 1.3.6.1.4.1.14817.7.3.1.2.36.20 | FourRFSerialNumber | read-only | current |
| aprisaXETransmitterReturnLoss OBJECT-TYPE The return loss for the transmitter. | 1.3.6.1.4.1.14817.7.3.1.2.36.21 | AprisaXEDbValue | read-only | current |
| aprisaXETransmitterMibDataStatus OBJECT-TYPE The status of the transmitter MIB data. | 1.3.6.1.4.1.14817.7.3.1.2.36.22 | AprisaXEDataStatus | read-only | current |
| aprisaXETransmitterADCChZero OBJECT-TYPE The TX adc ch zero voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.23 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChOne OBJECT-TYPE The TX adc ch one voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.24 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChTwo OBJECT-TYPE The TX adc ch two voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.25 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChThree OBJECT-TYPE The TX adc ch three voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.26 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChFour OBJECT-TYPE The TX adc ch four voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.27 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChFive OBJECT-TYPE The TX adc ch five voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.28 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChSix OBJECT-TYPE The TX adc ch six voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.29 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChSeven OBJECT-TYPE The TX adc ch seven voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.30 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChEight OBJECT-TYPE The TX adc ch eight voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.31 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChNine OBJECT-TYPE The TX adc ch nine voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.32 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChTen OBJECT-TYPE The TX adc ch ten voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.33 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterADCChEleven OBJECT-TYPE The TX adc ch eleven voltage. | 1.3.6.1.4.1.14817.7.3.1.2.36.34 | AprisaXEAdcVoltage | read-only | current |
| aprisaXETransmitterNeg5VPowerStatus OBJECT-TYPE The status of the transmitter Negative 5V power supply. | 1.3.6.1.4.1.14817.7.3.1.2.36.35 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitterAmplifierBalanceStatus OBJECT-TYPE The status of the transmitter Balanced Power Amplifier. | 1.3.6.1.4.1.14817.7.3.1.2.36.36 | FourRFAlarmStatus | read-only | current |
| aprisaXETransmitterTcxoAdjustment OBJECT-TYPE The TX TCXO adjustment to be made by the customer, to tune the TCXO. This is a shift in DAC steps. | 1.3.6.1.4.1.14817.7.3.1.2.36.37 | INTEGER {txTCXOAdjustmentPosFive(0), txTCXOAdjustmentPosOne(1), txTCXOAdjustmentZero(2), txTCXOAdjustmentNegOne(3), txTCXOAdjustmentNegFive(4)} | read-write | current |
| aprisaXETransmitterSynthFileVersion OBJECT-TYPE The version of the Synth File loaded from the filesystem. | 1.3.6.1.4.1.14817.7.3.1.2.36.38 | INTEGER (0..999) | read-only | current |
| aprisaXETransmitterOperationalDataVersion OBJECT-TYPE The version of the operational data for the transmitter. | 1.3.6.1.4.1.14817.7.3.1.2.36.39 | DisplayString | read-only | current |
| aprisaXETransmitterSwCompatibility OBJECT-TYPE The transmitter software compatibility number. | 1.3.6.1.4.1.14817.7.3.1.2.36.40 | INTEGER (0..999) | read-only | current |
| aprisaXEReceiver OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.51 | |||
| aprisaXEReceiverStatus OBJECT-TYPE Status of the receiver, currently the receiver can be On/Off and the loopback can be On/Off. | 1.3.6.1.4.1.14817.7.3.1.2.51.1 | INTEGER {receiverOff(0), receiverOn(1)} | read-only | current |
| aprisaXEReceiverCommand OBJECT-TYPE Commands used to control the receiver, currently the receiver can be switched on and off and the loopback option switched on and off. | 1.3.6.1.4.1.14817.7.3.1.2.51.2 | INTEGER {noCommand(0), receiverOff(1), receiverOn(2)} | read-write | current |
| aprisaXEReceiverSynthesiserStatus OBJECT-TYPE The status of the receiver synthesiser. | 1.3.6.1.4.1.14817.7.3.1.2.51.3 | FourRFAlarmStatus | read-only | current |
| aprisaXEReceiver12VPowerStatus OBJECT-TYPE The status of the Receiver 12V power supply. | 1.3.6.1.4.1.14817.7.3.1.2.51.4 | FourRFAlarmStatus | read-only | current |
| aprisaXEReceiverFrequency OBJECT-TYPE The terminal transmit frequency in MHz. The possible bands are: 330 to 400 MHz (300 MHz) 400 to 470 MHz (400 MHz) 1350 to 1550 MHz (1400 MHz) The frequency value should be supplied in Hz. | 1.3.6.1.4.1.14817.7.3.1.2.51.5 | FourRFFrequency | read-write | current |
| aprisaXEReceiverRSSI OBJECT-TYPE The characterised RSSI Voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.6 | FourRFRSSI | read-only | current |
| aprisaXEReceiverTemperature OBJECT-TYPE The temperature value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.8 | FourRFTemperature | read-only | current |
| aprisaXEReceiverVTune OBJECT-TYPE The voltage output from RX synth value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.9 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiver9VSupply OBJECT-TYPE The 9V supply rail value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.10 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiver5VSupply OBJECT-TYPE The 5V supply rail value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.11 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiverModemAGC OBJECT-TYPE The modem AGC, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.12 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiverNeg1V5Supply OBJECT-TYPE The -1.5V supply rail value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.13 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiver3V3Supply OBJECT-TYPE The 3.3V supply rail value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.14 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiverDacTest OBJECT-TYPE The DacTest value, this should only be accessible in engineering mode. | 1.3.6.1.4.1.14817.7.3.1.2.51.15 | AprisaXEAdcVoltage | read-only | obsolete |
| aprisaXEReceiverCharacterisationDataStatus OBJECT-TYPE The status of the receiver characterisation data. | 1.3.6.1.4.1.14817.7.3.1.2.51.16 | AprisaXEDataStatus | read-only | current |
| aprisaXEReceiverSerialNumber OBJECT-TYPE The unique module serial number for the receiver. | 1.3.6.1.4.1.14817.7.3.1.2.51.17 | FourRFSerialNumber | read-only | current |
| aprisaXEReceiverRfLoopback OBJECT-TYPE Enables and disabled RF loopback. | 1.3.6.1.4.1.14817.7.3.1.2.51.18 | FourRFLoopback | read-write | current |
| aprisaXEReceiverRfLoopbackTimeout OBJECT-TYPE The number of seconds after which RF loopback should timeout. | 1.3.6.1.4.1.14817.7.3.1.2.51.19 | Unsigned32 | read-write | current |
| aprisaXEReceiverMibDataStatus OBJECT-TYPE The status of the receiver MIB data. | 1.3.6.1.4.1.14817.7.3.1.2.51.20 | AprisaXEDataStatus | read-only | current |
| aprisaXEReceiverADCChZero OBJECT-TYPE The RX adc ch zero voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.21 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChOne OBJECT-TYPE The RX adc ch one voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.22 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChTwo OBJECT-TYPE The RX adc ch two voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.23 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChThree OBJECT-TYPE The RX adc ch three voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.24 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChFour OBJECT-TYPE The RX adc ch four voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.25 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChFive OBJECT-TYPE The RX adc ch five voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.26 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChSix OBJECT-TYPE The RX adc ch six voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.27 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChSeven OBJECT-TYPE The RX adc ch seven voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.28 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChEight OBJECT-TYPE The RX adc ch eight voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.29 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChNine OBJECT-TYPE The RX adc ch nine voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.30 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverADCChTen OBJECT-TYPE The RX adc ch ten voltage. | 1.3.6.1.4.1.14817.7.3.1.2.51.31 | AprisaXEAdcVoltage | read-only | current |
| aprisaXEReceiverRSSIThresQPSKLowerOn OBJECT-TYPE The QPSK Lower ON RSSI Threshold. | 1.3.6.1.4.1.14817.7.3.1.2.51.32 | Integer32 (-110..-40) | read-write | current |
| aprisaXEReceiverRSSIThres16QAMLowerOn OBJECT-TYPE The 16QAM Lower ON RSSI Threshold. | 1.3.6.1.4.1.14817.7.3.1.2.51.33 | Integer32 (-110..-40) | read-write | current |
| aprisaXEReceiverRSSIThres32QAMLowerOn OBJECT-TYPE The 32QAM Lower ON RSSI Threshold. | 1.3.6.1.4.1.14817.7.3.1.2.51.34 | Integer32 (-110..-40) | read-write | current |
| aprisaXEReceiverRSSIThres64QAMLowerOn OBJECT-TYPE The 64QAM Lower ON RSSI Threshold. | 1.3.6.1.4.1.14817.7.3.1.2.51.35 | Integer32 (-110..-40) | read-write | current |
| aprisaXEReceiverSynthFileVersion OBJECT-TYPE The version of the Synth File loaded from the filesystem. | 1.3.6.1.4.1.14817.7.3.1.2.51.36 | INTEGER (0..999) | read-only | current |
| aprisaXEReceiverOperationalDataVersion OBJECT-TYPE The version of the operational data of the receiver. | 1.3.6.1.4.1.14817.7.3.1.2.51.37 | DisplayString | read-only | current |
| aprisaXEReceiverSwCompatibility OBJECT-TYPE The receiver software compatibility number. | 1.3.6.1.4.1.14817.7.3.1.2.51.38 | INTEGER (0..999) | read-only | current |
| aprisaXEModem OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.61 | |||
| aprisaXEModemDemodAligmentStatus OBJECT-TYPE Status of the demodulator alignment. | 1.3.6.1.4.1.14817.7.3.1.2.61.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemTdmAligmentStatus OBJECT-TYPE Status of the TDM alignment. | 1.3.6.1.4.1.14817.7.3.1.2.61.2 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemRefAStatus OBJECT-TYPE Status of the REFa clock. | 1.3.6.1.4.1.14817.7.3.1.2.61.3 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemRefBStatus OBJECT-TYPE Status of the REFb clock. | 1.3.6.1.4.1.14817.7.3.1.2.61.4 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemUncorrectableBlockCount OBJECT-TYPE Count of uncorrectable blocks since last read. | 1.3.6.1.4.1.14817.7.3.1.2.61.5 | FourRFErrorCounter | read-only | current |
| aprisaXEModemIQData OBJECT-TYPE A list of I/Q data pairs, this is a sequence of byes values the first byte is an I value, the second a Q value. | 1.3.6.1.4.1.14817.7.3.1.2.61.6 | AprisaXEIQData | read-only | current |
| aprisaXEModemSyncStatus OBJECT-TYPE Status of the link lock. | 1.3.6.1.4.1.14817.7.3.1.2.61.7 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemFreqOffsetEnable OBJECT-TYPE Turn the Modulator frequency offset of 50kHz on or off. | 1.3.6.1.4.1.14817.7.3.1.2.61.8 | INTEGER {offsetDisabled(0), offsetEnabled(1)} | read-write | current |
| aprisaXEModemInterleaverEnable OBJECT-TYPE Interleaver being used on the modem. Trade off between link latency and FEC performance. | 1.3.6.1.4.1.14817.7.3.1.2.61.9 | INTEGER {interleaverEnabled(100), interleaverDisabled(101), interleaverDefault(102)} | read-write | current |
| aprisaXEModemQPSKCoding OBJECT-TYPE Encoding and Decoding being used for QPSK. Can be either Gray coded or non Gray coded. | 1.3.6.1.4.1.14817.7.3.1.2.61.10 | INTEGER {grayCoded(0), nonGrayCoded(1)} | read-write | current |
| aprisaXEModemConfigVersion OBJECT-TYPE Modem Configuration file version. | 1.3.6.1.4.1.14817.7.3.1.2.61.11 | INTEGER (0..999) | read-only | current |
| aprisaXEBoardTable OBJECT-TYPE This table stores the basic information for the plugin slots. | 1.3.6.1.4.1.14817.7.3.1.2.66 | not-accessible | current | |
| aprisaXEBoardEntry OBJECT-TYPE Slot Information. | 1.3.6.1.4.1.14817.7.3.1.2.66.1 | not-accessible | current | |
| aprisaXEBoardSlot OBJECT-TYPE The slot number in which the board resides, the physical slots are numbered from zero to ten and mapped to one to eleven in the MIB. The motherboard is therefore in physical slot 0 but MIB slot 1. | 1.3.6.1.4.1.14817.7.3.1.2.66.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEBoardType OBJECT-TYPE The type of the board in the slot. The types are as follows: - none : there is no card in the slot - modem : this card will be fitted in physical slot 0 - transmitter : the transmitter card, this will be in physical slot 9 - receiver : the receiver card, this will be in physical slot 10 - quadJET : e1/t1 4 port card | 1.3.6.1.4.1.14817.7.3.1.2.66.1.2 | AprisaXECardType | read-only | current |
| aprisaXEExpectedBoardType OBJECT-TYPE The type of the board expected in the slot. The types are as follows: - none : there is no card in the slot - modem : this card will be fitted in physical slot 0 - transmitter : the transmitter card, this will be in physical slot 9 - receiver : the receiver card, this will be in physical slot 10 - quadJET : e1/t1 4 port card | 1.3.6.1.4.1.14817.7.3.1.2.66.1.3 | AprisaXECardType | read-write | current |
| aprisaXEBoardHardwareVersion OBJECT-TYPE Field indicating the hardware version for the board in the slot. | 1.3.6.1.4.1.14817.7.3.1.2.66.1.4 | AprisaXEHardwareVersion | read-only | current |
| aprisaXEBoardFirmwareVersion OBJECT-TYPE Field indicating the firmware version for the board in the slot. | 1.3.6.1.4.1.14817.7.3.1.2.66.1.5 | AprisaXEHardwareVersion | read-only | current |
| aprisaXEBoardHSCNumber OBJECT-TYPE Field indicating the hardware software configuration number for the board in the slot. | 1.3.6.1.4.1.14817.7.3.1.2.66.1.6 | AprisaXEHardwareVersion | read-only | current |
| aprisaXEBoardSerialNumber OBJECT-TYPE Field indicating the module serial number for the card in the slot. | 1.3.6.1.4.1.14817.7.3.1.2.66.1.7 | FourRFSerialNumber | read-only | current |
| aprisaXELinkAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86 | |||
| aprisaXETransmitterAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1 | |||
| aprisaXEForwardPowerHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1 | |||
| aprisaXEForwardPowerHiAlarmStatus OBJECT-TYPE The status of the forward power too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEForwardPowerHiAlarmSeverity OBJECT-TYPE The severity of the forward power too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXEForwardPowerHiAlarmEnabled OBJECT-TYPE Indicates whether the forward power too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXEForwardPowerHiAlarmThreshold OBJECT-TYPE Indicates the level at which the forward power too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1.4 | Integer32 | read-only | obsolete |
| aprisaXEForwardPowerHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the forward power alarm will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.1.5 | Integer32 | read-only | obsolete |
| aprisaXEForwardPowerLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2 | |||
| aprisaXEForwardPowerLoAlarmStatus OBJECT-TYPE The status of the forward power too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEForwardPowerLoAlarmSeverity OBJECT-TYPE The severity of the forward power too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXEForwardPowerLoAlarmEnabled OBJECT-TYPE Indicates whether the forward power too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXEForwardPowerLoAlarmThreshold OBJECT-TYPE Indicates the level at which the forward power too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2.4 | Integer32 | read-only | obsolete |
| aprisaXEForwardPowerLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the forward power too low alarm will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.2.5 | Integer32 | read-only | obsolete |
| aprisaXEReversePowerHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3 | |||
| aprisaXEReversePowerHiAlarmStatus OBJECT-TYPE The status of the reverse power out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEReversePowerHiAlarmSeverity OBJECT-TYPE The severity of the reverse power out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXEReversePowerHiAlarmEnabled OBJECT-TYPE Indicates whether the reverse power out of limits alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXEReversePowerHiAlarmThreshold OBJECT-TYPE Indicates the level at which the reverse power alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3.4 | Integer32 | read-only | obsolete |
| aprisaXEReversePowerHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the reverse power alarm will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.3.5 | Integer32 | read-only | obsolete |
| aprisaXEReversePowerLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4 | |||
| aprisaXEReversePowerLoAlarmStatus OBJECT-TYPE The status of the reverse power out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXEReversePowerLoAlarmSeverity OBJECT-TYPE The severity of the reverse power out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXEReversePowerLoAlarmEnabled OBJECT-TYPE Indicates whether the reverse power out of limits alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXEReversePowerLoAlarmThreshold OBJECT-TYPE Indicates the level at which the reverse power alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4.4 | Integer32 | read-only | obsolete |
| aprisaXEReversePowerLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the reverse power alarm will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.4.5 | Integer32 | read-only | obsolete |
| aprisaXETxPaTempAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5 | |||
| aprisaXETxPaTempAlarmStatus OBJECT-TYPE The status of the transmitter temperature too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxPaTempAlarmSeverity OBJECT-TYPE The severity of the transmitter temperature too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxPaTempAlarmEnabled OBJECT-TYPE Indicates whether the transmitter temperature too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxPaTempAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter temperature too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5.4 | Integer32 | read-only | obsolete |
| aprisaXETxPaTempAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter temperature too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.5.5 | Integer32 | read-only | obsolete |
| aprisaXETxPaTempWarnAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6 | |||
| aprisaXETxPaTempWarnAlarmStatus OBJECT-TYPE The status of the transmitter temperature warning alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxPaTempWarnAlarmSeverity OBJECT-TYPE The severity of the transmitter temperature warning alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxPaTempWarnAlarmEnabled OBJECT-TYPE Indicates whether the transmitter temperature warning alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxPaTempWarnAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter temperature warning alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6.4 | Integer32 | read-only | obsolete |
| aprisaXETxPaTempWarnAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter temperature warning will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.6.5 | Integer32 | read-only | obsolete |
| aprisaXETxAgcHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7 | |||
| aprisaXETxAgcHiAlarmStatus OBJECT-TYPE The status of the transmitter AGC too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxAgcHiAlarmSeverity OBJECT-TYPE The severity of the transmitter AGC too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxAgcHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter AGC too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxAgcHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter AGC too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7.4 | Integer32 | read-only | obsolete |
| aprisaXETxAgcHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter AGC too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.7.5 | Integer32 | read-only | obsolete |
| aprisaXETxAgcLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8 | |||
| aprisaXETxAgcLoAlarmStatus OBJECT-TYPE The status of the transmitter AGC too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxAgcLoAlarmSeverity OBJECT-TYPE The severity of the transmitter AGC too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxAgcLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter AGC too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxAgcLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter AGC too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8.4 | Integer32 | read-only | obsolete |
| aprisaXETxAgcLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter AGC too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.8.5 | Integer32 | read-only | obsolete |
| aprisaXETxVtuneHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9 | |||
| aprisaXETxVtuneHiAlarmStatus OBJECT-TYPE The status of the transmitter VTUNE too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxVtuneHiAlarmSeverity OBJECT-TYPE The severity of the transmitter VTUNE too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxVtuneHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter VTUNE too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxVtuneHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter VTUNE too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9.4 | Integer32 | read-only | obsolete |
| aprisaXETxVtuneHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter VTUNE too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.9.5 | Integer32 | read-only | obsolete |
| aprisaXETxVtuneLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10 | |||
| aprisaXETxVtuneLoAlarmStatus OBJECT-TYPE The status of the transmitter VTUNE too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETxVtuneLoAlarmSeverity OBJECT-TYPE The severity of the transmitter VTUNE too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETxVtuneLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter VTUNE too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETxVtuneLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter VTUNE too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10.4 | Integer32 | read-only | obsolete |
| aprisaXETxVtuneLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter VTUNE too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.10.5 | Integer32 | read-only | obsolete |
| aprisaXETx5VDigHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11 | |||
| aprisaXETx5VDigHiAlarmStatus OBJECT-TYPE The status of the transmitter 5V digital voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx5VDigHiAlarmSeverity OBJECT-TYPE The severity of the transmitter 5V digital voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx5VDigHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 5V digital voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx5VDigHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 5V digital voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11.4 | Integer32 | read-only | obsolete |
| aprisaXETx5VDigHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 5V digital voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.11.5 | Integer32 | read-only | obsolete |
| aprisaXETx5VDigLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12 | |||
| aprisaXETx5VDigLoAlarmStatus OBJECT-TYPE The status of the transmitter 5V digital voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx5VDigLoAlarmSeverity OBJECT-TYPE The severity of the transmitter 5V digital voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx5VDigLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 5V digital voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx5VDigLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 5V digital voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12.4 | Integer32 | read-only | obsolete |
| aprisaXETx5VDigLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 5V digital voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.12.5 | Integer32 | read-only | obsolete |
| aprisaXETx7VRfHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13 | |||
| aprisaXETx7VRfHiAlarmStatus OBJECT-TYPE The status of the transmitter 7V RF voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx7VRfHiAlarmSeverity OBJECT-TYPE The severity of the transmitter 7V RF voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx7VRfHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 7V RF voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx7VRfHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 7V RF voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13.4 | Integer32 | read-only | obsolete |
| aprisaXETx7VRfHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 7V RF voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.13.5 | Integer32 | read-only | obsolete |
| aprisaXETx7VRfLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14 | |||
| aprisaXETx7VRfLoAlarmStatus OBJECT-TYPE The status of the transmitter 7V RF voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx7VRfLoAlarmSeverity OBJECT-TYPE The severity of the transmitter 7V RF voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx7VRfLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 7V RF voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx7VRfLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 7V RF voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14.4 | Integer32 | read-only | obsolete |
| aprisaXETx7VRfLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 7V RF voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.14.5 | Integer32 | read-only | obsolete |
| aprisaXETx9VHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15 | |||
| aprisaXETx9VHiAlarmStatus OBJECT-TYPE The status of the transmitter 9V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx9VHiAlarmSeverity OBJECT-TYPE The severity of the transmitter 9V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx9VHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 9V voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx9VHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 9V voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15.4 | Integer32 | read-only | obsolete |
| aprisaXETx9VHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 9V voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.15.5 | Integer32 | read-only | obsolete |
| aprisaXETx9VLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16 | |||
| aprisaXETx9VLoAlarmStatus OBJECT-TYPE The status of the transmitter 9V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx9VLoAlarmSeverity OBJECT-TYPE The severity of the transmitter 9V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx9VLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 9V voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx9VLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 9V voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16.4 | Integer32 | read-only | obsolete |
| aprisaXETx9VLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 9V voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.16.5 | Integer32 | read-only | obsolete |
| aprisaXETx11VHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17 | |||
| aprisaXETx11VHiAlarmStatus OBJECT-TYPE The status of the transmitter 11V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx11VHiAlarmSeverity OBJECT-TYPE The severity of the transmitter 11V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx11VHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 11V voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx11VHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 11V voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17.4 | Integer32 | read-only | obsolete |
| aprisaXETx11VHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 11V voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.17.5 | Integer32 | read-only | obsolete |
| aprisaXETx11VLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18 | |||
| aprisaXETx11VLoAlarmStatus OBJECT-TYPE The status of the transmitter 11V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx11VLoAlarmSeverity OBJECT-TYPE The severity of the transmitter 11V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx11VLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 11V voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx11VLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 11V voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18.4 | Integer32 | read-only | obsolete |
| aprisaXETx11VLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 11V voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.18.5 | Integer32 | read-only | obsolete |
| aprisaXETx28VHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19 | |||
| aprisaXETx28VHiAlarmStatus OBJECT-TYPE The status of the transmitter 28V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx28VHiAlarmSeverity OBJECT-TYPE The severity of the transmitter 28V voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx28VHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 28V voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx28VHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 28V voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19.4 | Integer32 | read-only | obsolete |
| aprisaXETx28VHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 28V voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.19.5 | Integer32 | read-only | obsolete |
| aprisaXETx28VLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20 | |||
| aprisaXETx28VLoAlarmStatus OBJECT-TYPE The status of the transmitter 28V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXETx28VLoAlarmSeverity OBJECT-TYPE The severity of the transmitter 28V voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXETx28VLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter 28V voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXETx28VLoAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter 28V voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20.4 | Integer32 | read-only | obsolete |
| aprisaXETx28VLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter 28V voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.20.5 | Integer32 | read-only | obsolete |
| aprisaXETxSynthOutOfLockAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.21 | |||
| aprisaXETxSynthOutOfLockAlarmStatus OBJECT-TYPE The status of the TX synth out of lock alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.21.1 | FourRFAlarmStatus | read-only | current |
| aprisaXETxSynthOutOfLockAlarmSeverity OBJECT-TYPE The severity of the TX synth out of lock alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.21.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxSynthOutOfLockAlarmEnabled OBJECT-TYPE Indicates whether the TX synth out of lock alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.21.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXEReturnLossHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22 | |||
| aprisaXEReturnLossHiAlarmStatus OBJECT-TYPE The status of the return loss out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEReturnLossHiAlarmSeverity OBJECT-TYPE The severity of the return loss out of limits alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXEReturnLossHiAlarmEnabled OBJECT-TYPE Indicates whether the return loss out of limits alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXEReturnLossHiAlarmThreshold OBJECT-TYPE Indicates the level at which the return loss alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22.4 | Integer32 | read-write | current |
| aprisaXEReturnLossHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the return loss alarm will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.22.5 | Integer32 | read-write | current |
| aprisaXETxADCChZeroHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23 | |||
| aprisaXETxADCChZeroHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.1 | DisplayString | read-only | current |
| aprisaXETxADCChZeroHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChZeroHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChZeroHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Zero voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChZeroHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Zero voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.5 | Integer32 | read-only | current |
| aprisaXETxADCChZeroHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Zero voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.23.6 | Integer32 | read-only | current |
| aprisaXETxADCChZeroLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24 | |||
| aprisaXETxADCChZeroLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.1 | DisplayString | read-only | current |
| aprisaXETxADCChZeroLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChZeroLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChZeroLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Zero voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChZeroLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.5 | Integer32 | read-only | current |
| aprisaXETxADCChZeroLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.24.6 | Integer32 | read-only | current |
| aprisaXETxADCChOneHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25 | |||
| aprisaXETxADCChOneHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.1 | DisplayString | read-only | current |
| aprisaXETxADCChOneHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChOneHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChOneHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch One voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChOneHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch One voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.5 | Integer32 | read-only | current |
| aprisaXETxADCChOneHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch One voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.25.6 | Integer32 | read-only | current |
| aprisaXETxADCChOneLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26 | |||
| aprisaXETxADCChOneLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.1 | DisplayString | read-only | current |
| aprisaXETxADCChOneLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChOneLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChOneLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch One voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChOneLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch One voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.5 | Integer32 | read-only | current |
| aprisaXETxADCChOneLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch One voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.6 | Integer32 | read-only | current |
| aprisaXETxADCChTwoHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27 | |||
| aprisaXETxADCChTwoHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.1 | DisplayString | read-only | current |
| aprisaXETxADCChTwoHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChTwoHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChTwoHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Two voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChTwoHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Two voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.5 | Integer32 | read-only | current |
| aprisaXETxADCChTwoHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Two voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.27.6 | Integer32 | read-only | current |
| aprisaXETxADCChTwoLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28 | |||
| aprisaXETxADCChTwoLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.1 | DisplayString | read-only | current |
| aprisaXETxADCChTwoLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChTwoLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChTwoLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Two voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChTwoLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Two voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.5 | Integer32 | read-only | current |
| aprisaXETxADCChTwoLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Two voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.28.6 | Integer32 | read-only | current |
| aprisaXETxADCChThreeHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29 | |||
| aprisaXETxADCChThreeHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.1 | DisplayString | read-only | current |
| aprisaXETxADCChThreeHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChThreeHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChThreeHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Three voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChThreeHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Three voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.5 | Integer32 | read-only | current |
| aprisaXETxADCChThreeHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Three voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.29.6 | Integer32 | read-only | current |
| aprisaXETxADCChThreeLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30 | |||
| aprisaXETxADCChThreeLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.1 | DisplayString | read-only | current |
| aprisaXETxADCChThreeLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChThreeLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChThreeLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Three voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChThreeLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Three voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.5 | Integer32 | read-only | current |
| aprisaXETxADCChThreeLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Three voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.30.6 | Integer32 | read-only | current |
| aprisaXETxADCChFourHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31 | |||
| aprisaXETxADCChFourHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.1 | DisplayString | read-only | current |
| aprisaXETxADCChFourHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChFourHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChFourHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Four voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChFourHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Four voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.5 | Integer32 | read-only | current |
| aprisaXETxADCChFourHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Four voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.31.6 | Integer32 | read-only | current |
| aprisaXETxADCChFourLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32 | |||
| aprisaXETxADCChFourLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.1 | DisplayString | read-only | current |
| aprisaXETxADCChFourLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChFourLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChFourLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Four voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChFourLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Four voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.5 | Integer32 | read-only | current |
| aprisaXETxADCChFourLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Four voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.32.6 | Integer32 | read-only | current |
| aprisaXETxADCChFiveHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33 | |||
| aprisaXETxADCChFiveHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.1 | DisplayString | read-only | current |
| aprisaXETxADCChFiveHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChFiveHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChFiveHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Five voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChFiveHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Five voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.5 | Integer32 | read-only | current |
| aprisaXETxADCChFiveHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Five voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.33.6 | Integer32 | read-only | current |
| aprisaXETxADCChFiveLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34 | |||
| aprisaXETxADCChFiveLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.1 | DisplayString | read-only | current |
| aprisaXETxADCChFiveLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChFiveLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChFiveLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Five voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChFiveLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Five voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.5 | Integer32 | read-only | current |
| aprisaXETxADCChFiveLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Five voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.34.6 | Integer32 | read-only | current |
| aprisaXETxADCChSixHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35 | |||
| aprisaXETxADCChSixHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.1 | DisplayString | read-only | current |
| aprisaXETxADCChSixHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChSixHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChSixHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Six voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChSixHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Six voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.5 | Integer32 | read-only | current |
| aprisaXETxADCChSixHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Six voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.35.6 | Integer32 | read-only | current |
| aprisaXETxADCChSixLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36 | |||
| aprisaXETxADCChSixLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.1 | DisplayString | read-only | current |
| aprisaXETxADCChSixLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChSixLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChSixLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Six voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChSixLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Six voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.5 | Integer32 | read-only | current |
| aprisaXETxADCChSixLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Six voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.36.6 | Integer32 | read-only | current |
| aprisaXETxADCChSevenHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37 | |||
| aprisaXETxADCChSevenHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.1 | DisplayString | read-only | current |
| aprisaXETxADCChSevenHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChSevenHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChSevenHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Seven voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChSevenHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Seven voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.5 | Integer32 | read-only | current |
| aprisaXETxADCChSevenHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Seven voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.37.6 | Integer32 | read-only | current |
| aprisaXETxADCChSevenLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38 | |||
| aprisaXETxADCChSevenLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.1 | DisplayString | read-only | current |
| aprisaXETxADCChSevenLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChSevenLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChSevenLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Seven voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChSevenLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.5 | Integer32 | read-only | current |
| aprisaXETxADCChSevenLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.38.6 | Integer32 | read-only | current |
| aprisaXETxADCChEightHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39 | |||
| aprisaXETxADCChEightHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.1 | DisplayString | read-only | current |
| aprisaXETxADCChEightHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChEightHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChEightHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Eight voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChEightHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Eight voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.5 | Integer32 | read-only | current |
| aprisaXETxADCChEightHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Eight voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.39.6 | Integer32 | read-only | current |
| aprisaXETxADCChEightLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40 | |||
| aprisaXETxADCChEightLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.1 | DisplayString | read-only | current |
| aprisaXETxADCChEightLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChEightLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChEightLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Eight voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChEightLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.5 | Integer32 | read-only | current |
| aprisaXETxADCChEightLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.40.6 | Integer32 | read-only | current |
| aprisaXETxADCChNineHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41 | |||
| aprisaXETxADCChNineHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.1 | DisplayString | read-only | current |
| aprisaXETxADCChNineHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChNineHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChNineHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Nine voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChNineHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Nine voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.5 | Integer32 | read-only | current |
| aprisaXETxADCChNineHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Nine voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.41.6 | Integer32 | read-only | current |
| aprisaXETxADCChNineLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42 | |||
| aprisaXETxADCChNineLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.1 | DisplayString | read-only | current |
| aprisaXETxADCChNineLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChNineLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChNineLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Nine voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChNineLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.5 | Integer32 | read-only | current |
| aprisaXETxADCChNineLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.42.6 | Integer32 | read-only | current |
| aprisaXETxADCChTenHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43 | |||
| aprisaXETxADCChTenHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.1 | DisplayString | read-only | current |
| aprisaXETxADCChTenHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChTenHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChTenHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Ten voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChTenHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Ten voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.5 | Integer32 | read-only | current |
| aprisaXETxADCChTenHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Ten voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.43.6 | Integer32 | read-only | current |
| aprisaXETxADCChTenLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44 | |||
| aprisaXETxADCChTenLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.1 | DisplayString | read-only | current |
| aprisaXETxADCChTenLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChTenLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChTenLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Ten voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChTenLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.5 | Integer32 | read-only | current |
| aprisaXETxADCChTenLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.44.6 | Integer32 | read-only | current |
| aprisaXETxADCChElevenHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45 | |||
| aprisaXETxADCChElevenHiAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Eleven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.1 | DisplayString | read-only | current |
| aprisaXETxADCChElevenHiAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Eleven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChElevenHiAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Eleven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChElevenHiAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Eleven voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChElevenHiAlarmThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Eleven voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.5 | Integer32 | read-only | current |
| aprisaXETxADCChElevenHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the transmitter ADC Ch Eleven voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.45.6 | Integer32 | read-only | current |
| aprisaXETxADCChElevenLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46 | |||
| aprisaXETxADCChElevenLoAlarmName OBJECT-TYPE The name of the transmitter ADC Ch Eleven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.1 | DisplayString | read-only | current |
| aprisaXETxADCChElevenLoAlarmStatus OBJECT-TYPE The status of the transmitter ADC Ch Eleven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.2 | FourRFAlarmStatus | read-only | current |
| aprisaXETxADCChElevenLoAlarmSeverity OBJECT-TYPE The severity of the transmitter ADC Ch Eleven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXETxADCChElevenLoAlarmEnabled OBJECT-TYPE Indicates whether the transmitter ADC Ch Eleven voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXETxADCChElevenLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.5 | Integer32 | read-only | current |
| aprisaXETxADCChElevenLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.1.46.6 | Integer32 | read-only | current |
| aprisaXEReceiverAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6 | |||
| aprisaXERxSynthOutOfLockAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.1 | |||
| aprisaXERxSynthOutOfLockAlarmStatus OBJECT-TYPE The status of the Synth out of lock alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.1.1 | FourRFAlarmStatus | read-only | current |
| aprisaXERxSynthOutOfLockAlarmSeverity OBJECT-TYPE The severity of the Synth out of lock alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.1.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxSynthOutOfLockAlarmEnabled OBJECT-TYPE Indicates whether the Synth out of lock alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.1.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXERx12VAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.3 | |||
| aprisaXERx12VAlarmStatus OBJECT-TYPE The status of the 12V supply alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.3.1 | FourRFAlarmStatus | read-only | current |
| aprisaXERx12VAlarmSeverity OBJECT-TYPE The severity of the 12V supply aprisaXERxVtuneLoAlarmalarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.3.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXERx12VAlarmEnabled OBJECT-TYPE Indicates whether the 12V supply alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.3.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXERx3V3HiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4 | |||
| aprisaXERx3V3HiAlarmStatus OBJECT-TYPE The status of the 3.3V supply high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx3V3HiAlarmSeverity OBJECT-TYPE The severity of the 3.3V supply high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx3V3HiAlarmEnabled OBJECT-TYPE Indicates whether the 3.3V supply high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx3V3HiAlarmThreshold OBJECT-TYPE Indicates the level at which the 3.3V supply high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4.4 | Integer32 | read-only | obsolete |
| aprisaXERx3V3HiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 3.3V supply high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.4.5 | Integer32 | read-only | obsolete |
| aprisaXERx3V3LoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5 | |||
| aprisaXERx3V3LoAlarmStatus OBJECT-TYPE The status of the 3.3V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx3V3LoAlarmSeverity OBJECT-TYPE The severity of the 3.3V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx3V3LoAlarmEnabled OBJECT-TYPE Indicates whether the 3.3V supply low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx3V3LoAlarmThreshold OBJECT-TYPE Indicates the level at which the 3.3V supply low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5.4 | Integer32 | read-only | obsolete |
| aprisaXERx3V3LoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 3.3V supply low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.5.5 | Integer32 | read-only | obsolete |
| aprisaXERx5VHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6 | |||
| aprisaXERx5VHiAlarmStatus OBJECT-TYPE The status of the 5V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx5VHiAlarmSeverity OBJECT-TYPE The severity of the 5V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx5VHiAlarmEnabled OBJECT-TYPE Indicates whether the 5V supply High alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx5VHiAlarmThreshold OBJECT-TYPE Indicates the level at which the 5V supply High alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6.4 | Integer32 | read-only | obsolete |
| aprisaXERx5VHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 5V supply High will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.6.5 | Integer32 | read-only | obsolete |
| aprisaXERx5VLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7 | |||
| aprisaXERx5VLoAlarmStatus OBJECT-TYPE The status of the 5V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx5VLoAlarmSeverity OBJECT-TYPE The severity of the 5V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx5VLoAlarmEnabled OBJECT-TYPE Indicates whether the 5V supply low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx5VLoAlarmThreshold OBJECT-TYPE Indicates the level at which the 5V supply low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7.4 | Integer32 | read-only | obsolete |
| aprisaXERx5VLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 5V supply low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.7.5 | Integer32 | read-only | obsolete |
| aprisaXERx9VHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8 | |||
| aprisaXERx9VHiAlarmStatus OBJECT-TYPE The status of the 9V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx9VHiAlarmSeverity OBJECT-TYPE The severity of the 9V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx9VHiAlarmEnabled OBJECT-TYPE Indicates whether the 9V supply High alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx9VHiAlarmThreshold OBJECT-TYPE Indicates the level at which the 9V supply High alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8.4 | Integer32 | read-only | obsolete |
| aprisaXERx9VHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 9V supply High will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.8.5 | Integer32 | read-only | obsolete |
| aprisaXERx9VLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9 | |||
| aprisaXERx9VLoAlarmStatus OBJECT-TYPE The status of the 9V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERx9VLoAlarmSeverity OBJECT-TYPE The severity of the 9V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERx9VLoAlarmEnabled OBJECT-TYPE Indicates whether the 9V supply low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERx9VLoAlarmThreshold OBJECT-TYPE Indicates the level at which the 9V supply low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9.4 | Integer32 | read-only | obsolete |
| aprisaXERx9VLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the 9V supply low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.9.5 | Integer32 | read-only | obsolete |
| aprisaXERxNeg1V5HiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10 | |||
| aprisaXERxNeg1V5HiAlarmStatus OBJECT-TYPE The status of the Neg 1.5V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxNeg1V5HiAlarmSeverity OBJECT-TYPE The severity of the Neg 1.5V supply High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxNeg1V5HiAlarmEnabled OBJECT-TYPE Indicates whether the Neg 1.5V supply High alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxNeg1V5HiAlarmThreshold OBJECT-TYPE Indicates the level at which the Neg 1.5V supply High alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10.4 | Integer32 | read-only | obsolete |
| aprisaXERxNeg1V5HiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the Neg 1.5V supply High will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.10.5 | Integer32 | read-only | obsolete |
| aprisaXERxNeg1V5LoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11 | |||
| aprisaXERxNeg1V5LoAlarmStatus OBJECT-TYPE The status of the Neg 1.5V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxNeg1V5LoAlarmSeverity OBJECT-TYPE The severity of the Neg 1.5V supply low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxNeg1V5LoAlarmEnabled OBJECT-TYPE Indicates whether the Neg 1.5V supply low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxNeg1V5LoAlarmThreshold OBJECT-TYPE Indicates the level at which the Neg 1.5V supply low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11.4 | Integer32 | read-only | obsolete |
| aprisaXERxNeg1V5LoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the Neg 1.5V supply low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.11.5 | Integer32 | read-only | obsolete |
| aprisaXERxAgcHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12 | |||
| aprisaXERxAgcHiAlarmStatus OBJECT-TYPE The status of the AGC high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxAgcHiAlarmSeverity OBJECT-TYPE The severity of the AGC high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxAgcHiAlarmEnabled OBJECT-TYPE Indicates whether the AGC high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxAgcHiAlarmThreshold OBJECT-TYPE Indicates the level at which the AGC high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12.4 | Integer32 | read-only | obsolete |
| aprisaXERxAgcHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the AGC high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.12.5 | Integer32 | read-only | obsolete |
| aprisaXERxAgcLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13 | |||
| aprisaXERxAgcLoAlarmStatus OBJECT-TYPE The status of the AGC low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxAgcLoAlarmSeverity OBJECT-TYPE The severity of the AGC low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxAgcLoAlarmEnabled OBJECT-TYPE Indicates whether the AGC low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxAgcLoAlarmThreshold OBJECT-TYPE Indicates the level at which the AGC low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13.4 | Integer32 | read-only | obsolete |
| aprisaXERxAgcLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the AGC low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.13.5 | Integer32 | read-only | obsolete |
| aprisaXERxRssiHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14 | |||
| aprisaXERxRssiHiAlarmStatus OBJECT-TYPE The status of the RSSI High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14.1 | FourRFAlarmStatus | read-only | current |
| aprisaXERxRssiHiAlarmSeverity OBJECT-TYPE The severity of the RSSI High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxRssiHiAlarmEnabled OBJECT-TYPE Indicates whether the RSSI High alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxRssiHiAlarmThreshold OBJECT-TYPE Indicates the level at which the RSSI High alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14.4 | Integer32 | read-only | current |
| aprisaXERxRssiHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the RSSI High will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.14.5 | Integer32 | read-only | current |
| aprisaXERxRssiLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15 | |||
| aprisaXERxRssiLoAlarmStatus OBJECT-TYPE The status of the RSSI low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15.1 | FourRFAlarmStatus | read-only | current |
| aprisaXERxRssiLoAlarmSeverity OBJECT-TYPE The severity of the RSSI low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxRssiLoAlarmEnabled OBJECT-TYPE Indicates whether the RSSI low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxRssiLoAlarmThreshold OBJECT-TYPE Indicates the level at which the RSSI low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15.4 | Integer32 | read-only | current |
| aprisaXERxRssiLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the RSSI low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.15.5 | Integer32 | read-only | current |
| aprisaXERxVtuneHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16 | |||
| aprisaXERxVtuneHiAlarmStatus OBJECT-TYPE The status of the Vtune High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxVtuneHiAlarmSeverity OBJECT-TYPE The severity of the Vtune High alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxVtuneHiAlarmEnabled OBJECT-TYPE Indicates whether the Vtune High alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxVtuneHiAlarmThreshold OBJECT-TYPE Indicates the level at which the Vtune High alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16.4 | Integer32 | read-only | obsolete |
| aprisaXERxVtuneHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the Vtune High will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.16.5 | Integer32 | read-only | obsolete |
| aprisaXERxVtuneLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17 | |||
| aprisaXERxVtuneLoAlarmStatus OBJECT-TYPE The status of the Vtune low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17.1 | FourRFAlarmStatus | read-only | obsolete |
| aprisaXERxVtuneLoAlarmSeverity OBJECT-TYPE The severity of the Vtune low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17.2 | FourRFAlarmSeverity | read-only | obsolete |
| aprisaXERxVtuneLoAlarmEnabled OBJECT-TYPE Indicates whether the Vtune low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17.3 | FourRFAlarmEnabled | read-only | obsolete |
| aprisaXERxVtuneLoAlarmThreshold OBJECT-TYPE Indicates the level at which the Vtune low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17.4 | Integer32 | read-only | obsolete |
| aprisaXERxVtuneLoAlarmClearThreshold OBJECT-TYPE Indicates the level at which the Vtune low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.17.5 | Integer32 | read-only | obsolete |
| aprisaXERxEEAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.18 | |||
| aprisaXERxEEAlarmStatus OBJECT-TYPE The status of the EEPROM alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.18.1 | FourRFAlarmStatus | read-only | current |
| aprisaXERxEEAlarmSeverity OBJECT-TYPE The severity of the EEPROM alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.18.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxEEAlarmEnabled OBJECT-TYPE Indicates whether the EEPROM alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.18.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChZeroHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19 | |||
| aprisaXERxADCChZeroHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.1 | DisplayString | read-only | current |
| aprisaXERxADCChZeroHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChZeroHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Zero voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChZeroHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Zero voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChZeroHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Zero voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.5 | Integer32 | read-only | current |
| aprisaXERxADCChZeroHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Zero voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.19.6 | Integer32 | read-only | current |
| aprisaXERxADCChZeroLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20 | |||
| aprisaXERxADCChZeroLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.1 | DisplayString | read-only | current |
| aprisaXERxADCChZeroLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChZeroLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Zero voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChZeroLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Zero voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChZeroLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Zero voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.5 | Integer32 | read-only | current |
| aprisaXERxADCChZeroLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Zero voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.20.6 | Integer32 | read-only | current |
| aprisaXERxADCChOneHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21 | |||
| aprisaXERxADCChOneHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.1 | DisplayString | read-only | current |
| aprisaXERxADCChOneHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChOneHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch One voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChOneHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch One voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChOneHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch One voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.5 | Integer32 | read-only | current |
| aprisaXERxADCChOneHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch One voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.21.6 | Integer32 | read-only | current |
| aprisaXERxADCChOneLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22 | |||
| aprisaXERxADCChOneLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.1 | DisplayString | read-only | current |
| aprisaXERxADCChOneLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChOneLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch One voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChOneLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch One voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChOneLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch One voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.5 | Integer32 | read-only | current |
| aprisaXERxADCChOneLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch One voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.22.6 | Integer32 | read-only | current |
| aprisaXERxADCChTwoHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23 | |||
| aprisaXERxADCChTwoHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.1 | DisplayString | read-only | current |
| aprisaXERxADCChTwoHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChTwoHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Two voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChTwoHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Two voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChTwoHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Two voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.5 | Integer32 | read-only | current |
| aprisaXERxADCChTwoHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Two voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.23.6 | Integer32 | read-only | current |
| aprisaXERxADCChTwoLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24 | |||
| aprisaXERxADCChTwoLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.1 | DisplayString | read-only | current |
| aprisaXERxADCChTwoLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChTwoLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Two voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChTwoLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Two voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChTwoLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Two voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.5 | Integer32 | read-only | current |
| aprisaXERxADCChTwoLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Two voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.24.6 | Integer32 | read-only | current |
| aprisaXERxADCChThreeHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25 | |||
| aprisaXERxADCChThreeHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.1 | DisplayString | read-only | current |
| aprisaXERxADCChThreeHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChThreeHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Three voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChThreeHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Three voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChThreeHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Three voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.5 | Integer32 | read-only | current |
| aprisaXERxADCChThreeHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Three voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.25.6 | Integer32 | read-only | current |
| aprisaXERxADCChThreeLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26 | |||
| aprisaXERxADCChThreeLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.1 | DisplayString | read-only | current |
| aprisaXERxADCChThreeLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChThreeLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Three voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChThreeLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Three voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChThreeLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Three voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.5 | Integer32 | read-only | current |
| aprisaXERxADCChThreeLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Three voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.26.6 | Integer32 | read-only | current |
| aprisaXERxADCChFourHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27 | |||
| aprisaXERxADCChFourHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.1 | DisplayString | read-only | current |
| aprisaXERxADCChFourHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChFourHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Four voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChFourHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Four voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChFourHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Four voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.5 | Integer32 | read-only | current |
| aprisaXERxADCChFourHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Four voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.27.6 | Integer32 | read-only | current |
| aprisaXERxADCChFourLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28 | |||
| aprisaXERxADCChFourLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.1 | DisplayString | read-only | current |
| aprisaXERxADCChFourLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChFourLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Four voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChFourLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Four voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChFourLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Four voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.5 | Integer32 | read-only | current |
| aprisaXERxADCChFourLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Four voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.28.6 | Integer32 | read-only | current |
| aprisaXERxADCChFiveHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29 | |||
| aprisaXERxADCChFiveHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.1 | DisplayString | read-only | current |
| aprisaXERxADCChFiveHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChFiveHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Five voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChFiveHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Five voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChFiveHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Five voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.5 | Integer32 | read-only | current |
| aprisaXERxADCChFiveHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Five voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.29.6 | Integer32 | read-only | current |
| aprisaXERxADCChFiveLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30 | |||
| aprisaXERxADCChFiveLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.1 | DisplayString | read-only | current |
| aprisaXERxADCChFiveLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChFiveLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Five voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChFiveLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Five voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChFiveLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Five voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.5 | Integer32 | read-only | current |
| aprisaXERxADCChFiveLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Five voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.30.6 | Integer32 | read-only | current |
| aprisaXERxADCChSixHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31 | |||
| aprisaXERxADCChSixHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.1 | DisplayString | read-only | current |
| aprisaXERxADCChSixHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChSixHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Six voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChSixHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Six voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChSixHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Six voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.5 | Integer32 | read-only | current |
| aprisaXERxADCChSixHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Six voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.31.6 | Integer32 | read-only | current |
| aprisaXERxADCChSixLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32 | |||
| aprisaXERxADCChSixLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.1 | DisplayString | read-only | current |
| aprisaXERxADCChSixLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChSixLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Six voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChSixLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Six voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChSixLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Six voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.5 | Integer32 | read-only | current |
| aprisaXERxADCChSixLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Six voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.32.6 | Integer32 | read-only | current |
| aprisaXERxADCChSevenHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33 | |||
| aprisaXERxADCChSevenHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.1 | DisplayString | read-only | current |
| aprisaXERxADCChSevenHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChSevenHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Seven voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChSevenHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Seven voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChSevenHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Seven voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.5 | Integer32 | read-only | current |
| aprisaXERxADCChSevenHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Seven voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.33.6 | Integer32 | read-only | current |
| aprisaXERxADCChSevenLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34 | |||
| aprisaXERxADCChSevenLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.1 | DisplayString | read-only | current |
| aprisaXERxADCChSevenLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChSevenLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Seven voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChSevenLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Seven voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChSevenLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Seven voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.5 | Integer32 | read-only | current |
| aprisaXERxADCChSevenLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Seven voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.34.6 | Integer32 | read-only | current |
| aprisaXERxADCChEightHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35 | |||
| aprisaXERxADCChEightHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.1 | DisplayString | read-only | current |
| aprisaXERxADCChEightHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChEightHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Eight voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChEightHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Eight voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChEightHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Eight voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.5 | Integer32 | read-only | current |
| aprisaXERxADCChEightHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Eight voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.35.6 | Integer32 | read-only | current |
| aprisaXERxADCChEightLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36 | |||
| aprisaXERxADCChEightLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.1 | DisplayString | read-only | current |
| aprisaXERxADCChEightLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChEightLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Eight voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChEightLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Eight voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChEightLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Eight voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.5 | Integer32 | read-only | current |
| aprisaXERxADCChEightLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Eight voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.36.6 | Integer32 | read-only | current |
| aprisaXERxADCChNineHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37 | |||
| aprisaXERxADCChNineHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.1 | DisplayString | read-only | current |
| aprisaXERxADCChNineHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChNineHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Nine voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChNineHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Nine voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChNineHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Nine voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.5 | Integer32 | read-only | current |
| aprisaXERxADCChNineHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Nine voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.37.6 | Integer32 | read-only | current |
| aprisaXERxADCChNineLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38 | |||
| aprisaXERxADCChNineLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.1 | DisplayString | read-only | current |
| aprisaXERxADCChNineLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChNineLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Nine voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChNineLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Nine voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChNineLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Nine voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.5 | Integer32 | read-only | current |
| aprisaXERxADCChNineLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Nine voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.38.6 | Integer32 | read-only | current |
| aprisaXERxADCChTenHiAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39 | |||
| aprisaXERxADCChTenHiAlarmName OBJECT-TYPE The name of the receiver ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.1 | DisplayString | read-only | current |
| aprisaXERxADCChTenHiAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChTenHiAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Ten voltage too high alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChTenHiAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Ten voltage too high alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChTenHiAlarmThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Ten voltage too high alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.5 | Integer32 | read-only | current |
| aprisaXERxADCChTenHiAlarmClearThreshold OBJECT-TYPE Indicates the level at which the receiver ADC Ch Ten voltage too high will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.39.6 | Integer32 | read-only | current |
| aprisaXERxADCChTenLoAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40 | |||
| aprisaXERxADCChTenLoAlarmName OBJECT-TYPE The name of the receiver ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.1 | DisplayString | read-only | current |
| aprisaXERxADCChTenLoAlarmStatus OBJECT-TYPE The status of the receiver ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.2 | FourRFAlarmStatus | read-only | current |
| aprisaXERxADCChTenLoAlarmSeverity OBJECT-TYPE The severity of the receiver ADC Ch Ten voltage too low alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.3 | FourRFAlarmSeverity | read-only | current |
| aprisaXERxADCChTenLoAlarmEnabled OBJECT-TYPE Indicates whether the receiver ADC Ch Ten voltage too low alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.4 | FourRFAlarmEnabled | read-only | current |
| aprisaXERxADCChTenLoAlarmThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Ten voltage too low alarm will be set. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.5 | Integer32 | read-only | current |
| aprisaXERxADCChTenLoAlarmClearThreshold OBJECT-TYPE Indicates the level at wLoch the receiver ADC Ch Ten voltage too low will be cleared. | 1.3.6.1.4.1.14817.7.3.1.2.86.6.40.6 | Integer32 | read-only | current |
| aprisaXEModemAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.10 | |||
| aprisaXEModemSyncAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.86.10.1 | |||
| aprisaXEModemSyncAlarmStatus OBJECT-TYPE The status of the loss of modem sync alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.10.1.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEModemSyncAlarmSeverity OBJECT-TYPE The severity of the loss of modem sync alarm. | 1.3.6.1.4.1.14817.7.3.1.2.86.10.1.2 | FourRFAlarmSeverity | read-only | current |
| aprisaXEModemSyncAlarmEnabled OBJECT-TYPE Indicates whether the loss of modem sync alarm is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.86.10.1.3 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetBoardTable OBJECT-TYPE Table of Quad E1 card specific configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.87 | not-accessible | current | |
| aprisaXEQuadJetBoardEntry OBJECT-TYPE Quad E1 configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.87.1 | not-accessible | current | |
| aprisaXEQuadJetBoardTableIndex OBJECT-TYPE Quad E1 board indexed by slot. | 1.3.6.1.4.1.14817.7.3.1.2.87.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEQuadJetPortTable OBJECT-TYPE Table based on slot and port of QuadJet cards alarms. | 1.3.6.1.4.1.14817.7.3.1.2.88 | not-accessible | current | |
| aprisaXEQuadJetPortEntry OBJECT-TYPE Quad E1 port alarms. | 1.3.6.1.4.1.14817.7.3.1.2.88.1 | not-accessible | current | |
| aprisaXEQuadJetPortTableSlot OBJECT-TYPE Port table index based on slot number. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEQuadJetPortTablePort OBJECT-TYPE Port table index based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEQuadJetLOFAlarmStatus OBJECT-TYPE Red alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.3 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetLOFAlarmSeverity OBJECT-TYPE Red alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.4 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetLOFAlarmEnabled OBJECT-TYPE Red alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.5 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetAISAlarmStatus OBJECT-TYPE AIS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.6 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetAISAlarmSeverity OBJECT-TYPE AIS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.7 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetAISAlarmEnabled OBJECT-TYPE AIS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.8 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetRAIAlarmStatus OBJECT-TYPE RAI alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.9 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetRAIAlarmSeverity OBJECT-TYPE RAI alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.10 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetRAIAlarmEnabled OBJECT-TYPE RAI alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.11 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetRMAIAlarmStatus OBJECT-TYPE RMAI alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.12 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetRMAIAlarmSeverity OBJECT-TYPE RMAI alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.13 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetRMAIAlarmEnabled OBJECT-TYPE RMAI alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.14 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetTS16AISAlarmStatus OBJECT-TYPE TS16 AIS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.15 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetTS16AISAlarmSeverity OBJECT-TYPE TS16 AIS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.16 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetTS16AISAlarmEnabled OBJECT-TYPE TS16 AIS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.17 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetTS16LOSAlarmStatus OBJECT-TYPE TS16 LOS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.18 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetTS16LOSAlarmSeverity OBJECT-TYPE TS16 LOS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.19 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetTS16LOSAlarmEnabled OBJECT-TYPE TS16 LOS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.20 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetLOSAlarmStatus OBJECT-TYPE LOS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.21 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetLOSAlarmSeverity OBJECT-TYPE LOS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.22 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetLOSAlarmEnabled OBJECT-TYPE LOS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.23 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetCRC4AlarmStatus OBJECT-TYPE CRC4 alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.24 | FourRFAlarmStatus | read-only | current |
| aprisaXEQuadJetCRC4AlarmSeverity OBJECT-TYPE CRC4 alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.25 | FourRFAlarmSeverity | read-only | current |
| aprisaXEQuadJetCRC4AlarmEnabled OBJECT-TYPE CRC4 alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.26 | FourRFAlarmEnabled | read-only | current |
| aprisaXEQuadJetCRC4AlarmThreshold OBJECT-TYPE CRC4 Threshold value for counter to alarm at. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.27 | Integer32 | read-only | current |
| aprisaXEQuadJetCRC4AlarmClearThreshold OBJECT-TYPE CRC4 Threshold at which alarm clears. | 1.3.6.1.4.1.14817.7.3.1.2.88.1.28 | Integer32 | read-only | current |
| aprisaXEQuadJetIFConfigTable OBJECT-TYPE Switch data table which describes the allocation of user data on to the TDM busses. | 1.3.6.1.4.1.14817.7.3.1.2.90 | not-accessible | current | |
| aprisaXEQuadJetIFConfigEntry OBJECT-TYPE Quad JET config data. | 1.3.6.1.4.1.14817.7.3.1.2.90.1 | not-accessible | current | |
| aprisaXEQuadJetIFConfigSlotIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEQuadJetIFConfigPortIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEQuadJetTrafficType OBJECT-TYPE Controls the traffic type on a Quad JET port. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.3 | AprisaXEQuadJetTrafficType | read-write | current |
| aprisaXEQuadJetLoopback OBJECT-TYPE Controls the traffic loopback on a Quad JET port. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.4 | FourRFLoopback | read-write | obsolete |
| aprisaXEQuadJetLineEncoding OBJECT-TYPE Controls the line encoding, the default is HDB3 for E1, B8ZS for T1. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.5 | AprisaXEQuadJetLineEncoding | read-write | current |
| aprisaXEQuadJetPcmMode OBJECT-TYPE Controls the PCM mode, PCM31 or PCM30C. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.6 | AprisaXEPcmMode | read-write | current |
| aprisaXEQuadJetClockSource OBJECT-TYPE Controls whether the port drives the clock soure or not. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.7 | FourRFNetworkClockSelect | read-write | current |
| aprisaXEQuadJetLineRadioLoopback OBJECT-TYPE This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.8 | AprisaXEQuadJetLoopbacks | read-write | current |
| aprisaXEQuadJetTxWaveFormShaper OBJECT-TYPE This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.9 | AprisaXEQuadJetWaveFormShapers | read-write | current |
| aprisaXEQuadJetMultiframeEnable OBJECT-TYPE Indicates whether support is enabled for transport of T1 SF and ESF multiframe sync for a port. | 1.3.6.1.4.1.14817.7.3.1.2.90.1.10 | AprisaXEQuadJetMultiframeEnable | read-write | current |
| aprisaXEQuadJetIFConnectionTable OBJECT-TYPE Interface connection table which holds all the cross connect information for the E1 card. | 1.3.6.1.4.1.14817.7.3.1.2.91 | not-accessible | current | |
| aprisaXEQuadJetIFConnectionTableEntry OBJECT-TYPE Quad JET cross connection data. | 1.3.6.1.4.1.14817.7.3.1.2.91.1 | not-accessible | current | |
| aprisaXEQuadJetIFConnectionID OBJECT-TYPE Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.91.1.1 | AprisaXEConnectionID | read-only | current |
| aprisaXEQuadJetIFConnectionAggregateID OBJECT-TYPE Aggregate ID, 0 if an unframed connection. | 1.3.6.1.4.1.14817.7.3.1.2.91.1.2 | AprisaXEConnectionID | read-only | current |
| aprisaXEQuadJetIFConnectionSlot OBJECT-TYPE Slot number that this card is in. | 1.3.6.1.4.1.14817.7.3.1.2.91.1.3 | AprisaXESlotNumber | read-only | current |
| aprisaXEQuadJetIFConnectionE1Port OBJECT-TYPE Port number associated with this connection. | 1.3.6.1.4.1.14817.7.3.1.2.91.1.4 | AprisaXEPortNumber | read-only | current |
| aprisaXEQuadJetIFConnectionType OBJECT-TYPE Indicates whether the connection is for data or CAS signalling. | 1.3.6.1.4.1.14817.7.3.1.2.91.1.5 | AprisaXEQuadJetConnectionType | read-only | current |
| aprisaXEQuadJetIFConnectionControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.93 | |||
| aprisaXEQuadJetIFControlConnectionID OBJECT-TYPE Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.93.1 | AprisaXEConnectionID | read-write | current |
| aprisaXEQuadJetIFControlAggregateID OBJECT-TYPE Aggregate Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.93.2 | AprisaXEConnectionID | read-write | current |
| aprisaXEQuadJetIFConnectionControlSlot OBJECT-TYPE Slot number that this card is in. | 1.3.6.1.4.1.14817.7.3.1.2.93.3 | AprisaXESlotNumber | read-write | current |
| aprisaXEQuadJetIFConnectionControlE1Port OBJECT-TYPE Port number associated with this connection. | 1.3.6.1.4.1.14817.7.3.1.2.93.4 | AprisaXEPortNumber | read-write | current |
| aprisaXEQuadJetIFConnectionControlType OBJECT-TYPE Indicates whether the connection is for data or CAS signalling. | 1.3.6.1.4.1.14817.7.3.1.2.93.5 | AprisaXEQuadJetConnectionType | read-write | current |
| aprisaXEQuadJetIFConnectionControlCommand OBJECT-TYPE Command to send to act upon the rows in the QuedJet Interface Connection table. | 1.3.6.1.4.1.14817.7.3.1.2.93.6 | INTEGER {noCommand(0), addCommand(1), deleteCommand(2)} | read-write | current |
| aprisaXEEthernetConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.95 | |||
| aprisaXEEthernetBandwidth OBJECT-TYPE This controls the bandwidth allocated to ethernet in kbps, the minimum block is 8kbps, values will be rounded up to the nearest 8kbps. | 1.3.6.1.4.1.14817.7.3.1.2.95.1 | Unsigned32 | read-write | current |
| aprisaXEEthernetManagementBandwidth OBJECT-TYPE This controls the bandwidth available to management traffic, a minimum of 8kbps is required. Values will be rounded up to the nearest 8kbps. | 1.3.6.1.4.1.14817.7.3.1.2.95.2 | Unsigned32 | read-write | current |
| aprisaXEEthernetCustomerConnectionID OBJECT-TYPE Backplane connection ID for Customer bandwidth. | 1.3.6.1.4.1.14817.7.3.1.2.95.3 | AprisaXEConnectionID | read-write | current |
| aprisaXEEthernetPBCConnectionID OBJECT-TYPE Backplane connection ID for Private Back Channel management bandwidth. | 1.3.6.1.4.1.14817.7.3.1.2.95.4 | AprisaXEConnectionID | read-write | current |
| aprisaXEEthernetPortTable OBJECT-TYPE Table used to control and monitor basic ethernet features on the 4-port hub. | 1.3.6.1.4.1.14817.7.3.1.2.96 | not-accessible | current | |
| aprisaXEEthernetPortEntry OBJECT-TYPE Ethernet port status and configuration. | 1.3.6.1.4.1.14817.7.3.1.2.96.1 | not-accessible | current | |
| aprisaXEEthernetPortIndex OBJECT-TYPE The port index, there are four ports on the hub. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.1 | INTEGER (1..4) | read-only | current |
| aprisaXEEthernetAutonegotiationStatus OBJECT-TYPE The status of the port auto-negotiation. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.2 | INTEGER {autoNegotiationNotComplete(0), autoNegotiationComplete(1)} | read-only | current |
| aprisaXEEthernetRemoteFaultStatus OBJECT-TYPE The status of the port remote fault detection. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.3 | INTEGER {remoteFaultNotDetected(0), remoteFaultDetected(1)} | read-only | current |
| aprisaXEEthernetLinkStatus OBJECT-TYPE The status of the port link. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.4 | INTEGER {down(0), up(1)} | read-only | current |
| aprisaXEEthernetJabberStatus OBJECT-TYPE Has jabber been detected on the port?. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.5 | INTEGER {jabberNotDetected(0), jabberDetected(1)} | read-only | current |
| aprisaXEEthernetSpeed OBJECT-TYPE The current port speed, 10 or 100 Mbps. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.6 | INTEGER {mbps10(0), mbps100(1)} | read-only | current |
| aprisaXEEthernetDuplexMode OBJECT-TYPE The current port duplex mode. | 1.3.6.1.4.1.14817.7.3.1.2.96.1.7 | INTEGER {halfDuplex(0), fullDuplex(1)} | read-only | current |
| aprisaXEEthernetTable OBJECT-TYPE Table used to display and configure Ethernet settings. | 1.3.6.1.4.1.14817.7.3.1.2.97 | not-accessible | current | |
| aprisaXEEthernetTableEntry OBJECT-TYPE Individual Ethernet port settings. | 1.3.6.1.4.1.14817.7.3.1.2.97.1 | not-accessible | current | |
| aprisaXEEthernetPortNum OBJECT-TYPE The port number, there are four ports on the hub. | 1.3.6.1.4.1.14817.7.3.1.2.97.1.1 | AprisaXEEthernetPortNumber | read-only | current |
| aprisaXEEthernetGroup OBJECT-TYPE The Ethernet Group of which this port is a member. | 1.3.6.1.4.1.14817.7.3.1.2.97.1.2 | AprisaXEEthernetGroup | read-write | current |
| aprisaXEEthernetIngressRate OBJECT-TYPE The ingress frame rate limit for this port. | 1.3.6.1.4.1.14817.7.3.1.2.97.1.3 | AprisaXEEthernetFrameRate | read-write | current |
| aprisaXEEthernetPortPriority OBJECT-TYPE Indicates the bandwidth allocated to this port. | 1.3.6.1.4.1.14817.7.3.1.2.97.1.4 | AprisaXEEthernetPortPriority | read-write | current |
| aprisaXEEthernetVlanQosSettings OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.98 | |||
| aprisaXEEthernetGrouping OBJECT-TYPE Indicates whether Ethernet grouping (VLANs) is enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.98.1 | AprisaXEEthernetGrouping | read-write | current |
| aprisaXEEthernetManagementGroup OBJECT-TYPE The Ethernet Group for management. | 1.3.6.1.4.1.14817.7.3.1.2.98.2 | AprisaXEEthernetGroup | read-only | current |
| aprisaXEEthernetPrioQueueScheduling OBJECT-TYPE Indicates Ethernet priority queue scheduling scheme (either strict or weighted). | 1.3.6.1.4.1.14817.7.3.1.2.98.3 | AprisaXEEthernetPrioQueueScheduling | read-write | current |
| aprisaXEEthernetPrioQueueMapping OBJECT-TYPE Indicates the IEEE 802.1 Ethernet priority queue mapping scheme (either standard or cisco). | 1.3.6.1.4.1.14817.7.3.1.2.98.4 | AprisaXEEthernetPrioQueueMapping | read-write | current |
| aprisaXEDefaultEthernetGrouping OBJECT-TYPE Indicates when Ethernet Grouping settings must be reset to default values. | 1.3.6.1.4.1.14817.7.3.1.2.98.5 | AprisaXEDefaultAction | read-write | current |
| aprisaXEDefaultEthernetQos OBJECT-TYPE Indicates when Ethernet Grouping settings must be reset to default values. | 1.3.6.1.4.1.14817.7.3.1.2.98.6 | AprisaXEDefaultAction | read-write | current |
| aprisaXEInterfaceTable OBJECT-TYPE Table used to monitor the current interface status. | 1.3.6.1.4.1.14817.7.3.1.2.100 | not-accessible | current | |
| aprisaXEInterfaceTableEntry OBJECT-TYPE Interface bandwidth and status. | 1.3.6.1.4.1.14817.7.3.1.2.100.1 | not-accessible | current | |
| aprisaXEInterfaceIndex OBJECT-TYPE The slot containing the interface card, slots 0 to 8 (AUX or A-H) inclusive may contain interface cards. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEInterfaceType OBJECT-TYPE Indicates the type of interface card. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.2 | AprisaXECardType | read-only | current |
| aprisaXEInterfaceAlarmStatus OBJECT-TYPE Indicates the current alarm status for the interface. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.3 | FourRFAlarmStatus | read-only | current |
| aprisaXEInterfacePort1Bandwidth OBJECT-TYPE Indicates the bandwidth allocated to port 1. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.4 | Unsigned32 | read-only | current |
| aprisaXEInterfacePort2Bandwidth OBJECT-TYPE Indicates the bandwidth allocated to port 2. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.5 | Unsigned32 | read-only | current |
| aprisaXEInterfacePort3Bandwidth OBJECT-TYPE Indicates the bandwidth allocated to port 3. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.6 | Unsigned32 | read-only | current |
| aprisaXEInterfacePort4Bandwidth OBJECT-TYPE Indicates the bandwidth allocated to port 4. | 1.3.6.1.4.1.14817.7.3.1.2.100.1.7 | Unsigned32 | read-only | current |
| aprisaXE4WirePortControlTable OBJECT-TYPE Status and Control table for 4Wire. | 1.3.6.1.4.1.14817.7.3.1.2.110 | not-accessible | current | |
| aprisaXE4WirePortControlTableEntry OBJECT-TYPE Entries for 4wire table. | 1.3.6.1.4.1.14817.7.3.1.2.110.1 | not-accessible | current | |
| aprisaXE4WireConnectionID OBJECT-TYPE Associated cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.1 | AprisaXEConnectionID | read-write | current |
| aprisaXE4WireSlotIndex OBJECT-TYPE Slot index for 4wire Status Control table. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.2 | AprisaXESlotNumber | read-only | current |
| aprisaXE4WirePortIndex OBJECT-TYPE Channel index for 4 Wire Control Status table. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.3 | AprisaXEPortNumber | read-only | current |
| aprisaXE4WireLoopback OBJECT-TYPE Loopback control on or off for channels. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.4 | FourRFLoopback | read-write | current |
| aprisaXE4WireAdpcmCompression OBJECT-TYPE ADPCM compression 16, 24, 32, 64 kbps or none. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.5 | AprisaXEAdpcmCompression | read-write | current |
| aprisaXE4WireRxGain OBJECT-TYPE Rx gain +4 dB to -14 dB in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.6 | AprisaXE4WRxGain | read-write | obsolete |
| aprisaXE4WireTxGain OBJECT-TYPE Tx gain +14 dB to -4 dB in half dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.7 | AprisaXE4WTxGain | read-write | obsolete |
| aprisaXE4WireEInvert OBJECT-TYPE Controls E on each channel for NORMAL or INVERT polarity. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.8 | AprisaXESignalState | read-write | current |
| aprisaXE4WireMInvert OBJECT-TYPE Controls M on each channel for NORMAL or INVERT polarity. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.9 | AprisaXESignalState | read-write | current |
| aprisaXE4WireSignalling OBJECT-TYPE Enables or disables E&M signalling for the port. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.10 | INTEGER {signallingOff(0), signallingOn(1)} | read-write | current |
| aprisaXE4WireSignallingConnectionID OBJECT-TYPE Associated signalling cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.11 | AprisaXEConnectionID | read-write | current |
| aprisaXE4WireInputLevel OBJECT-TYPE Input Level -14.0 dBr to +4.0 dBr in half dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.12 | AprisaXE4WInputLevel | read-write | current |
| aprisaXE4WireOutputLevel OBJECT-TYPE Output Level -14.0 dBr to +4.0 dBr in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.110.1.13 | AprisaXE4WOutputLevel | read-write | current |
| aprisaXE4WireStatusControlTable OBJECT-TYPE Overall card control and status. | 1.3.6.1.4.1.14817.7.3.1.2.121 | not-accessible | current | |
| aprisaXE4WireStatusControlTableEntry OBJECT-TYPE Status control entries. | 1.3.6.1.4.1.14817.7.3.1.2.121.1 | not-accessible | current | |
| aprisaXE4WireStatusControlSlotIndex OBJECT-TYPE Index for table. | 1.3.6.1.4.1.14817.7.3.1.2.121.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXE4WirePcmLaw OBJECT-TYPE Sets A-law or u-law. | 1.3.6.1.4.1.14817.7.3.1.2.121.1.2 | AprisaXEPcmLaw | read-write | current |
| aprisaXEFXOPortControlTable OBJECT-TYPE Port Control table for FXO. | 1.3.6.1.4.1.14817.7.3.1.2.130 | not-accessible | current | |
| aprisaXEFXOPortControlTableEntry OBJECT-TYPE Entries for FXO table. | 1.3.6.1.4.1.14817.7.3.1.2.130.1 | not-accessible | current | |
| aprisaXEFXOPortControlSlotIndex OBJECT-TYPE Slot index for FXO Control table. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEFXOPortIndex OBJECT-TYPE Port index for FXO Control table. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEFXOLoopback OBJECT-TYPE Loopback control on or off for ports. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.3 | FourRFLoopback | read-write | current |
| aprisaXEFXOAdpcmCompression OBJECT-TYPE ADPCM compression 16, 24, 32, 64 kbps or none. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.4 | AprisaXEAdpcmCompression | read-write | current |
| aprisaXEFXORxGain OBJECT-TYPE Rx gain -10 dB to 10 dB in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.5 | INTEGER {fxopos100(0), fxopos95(1), fxopos90(2), fxopos85(3), fxopos80(4), fxopos75(5), fxopos70(6), fxopos65(7), fxopos60(8), fxopos55(9), fxopos50(10), fxopos45(11), fxopos40(12), fxopos35(13), fxopos30(14), fxopos25(15), fxopos20(16), fxopos15(17), fxopos10(18), fxopos05(19), fxopos0(20), fxoneg05(21), fxoneg10(22), fxoneg15(23), fxoneg20(24), fxoneg25(25), fxoneg30(26), fxoneg35(27), fxoneg40(28), fxoneg45(29), fxoneg50(30), fxoneg55(31), fxoneg60(32), fxoneg65(33), fxoneg70(34), fxoneg75(35), fxoneg80(36), fxoneg85(37), fxoneg90(38), fxoneg95(39), fxoneg100(40)} | read-write | obsolete |
| aprisaXEFXOTxGain OBJECT-TYPE Tx gain -10 dB to 10 dB in half dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.6 | INTEGER {fxopos100(0), fxopos95(1), fxopos90(2), fxopos85(3), fxopos80(4), fxopos75(5), fxopos70(6), fxopos65(7), fxopos60(8), fxopos55(9), fxopos50(10), fxopos45(11), fxopos40(12), fxopos35(13), fxopos30(14), fxopos25(15), fxopos20(16), fxopos15(17), fxopos10(18), fxopos05(19), fxopos0(20), fxoneg05(21), fxoneg10(22), fxoneg15(23), fxoneg20(24), fxoneg25(25), fxoneg30(26), fxoneg35(27), fxoneg40(28), fxoneg45(29), fxoneg50(30), fxoneg55(31), fxoneg60(32), fxoneg65(33), fxoneg70(34), fxoneg75(35), fxoneg80(36), fxoneg85(37), fxoneg90(38), fxoneg95(39), fxoneg100(40)} | read-write | obsolete |
| aprisaXEFXOConnectionID OBJECT-TYPE Associated cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.7 | AprisaXEConnectionID | read-write | current |
| aprisaXEFXOSignallingConnectionID OBJECT-TYPE Associated signalling cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.8 | AprisaXEConnectionID | read-write | current |
| aprisaXEFXOInputLevel OBJECT-TYPE Input Level -10.0 dBr to +1.0 dBr in half dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.9 | AprisaXEFXOInputLevel | read-write | current |
| aprisaXEFXOOutputLevel OBJECT-TYPE Output Level -10.0 dBr to +1.0 dBr in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.130.1.10 | AprisaXEFXOOutputLevel | read-write | current |
| aprisaXEFXOControlTable OBJECT-TYPE Control table for FXO. | 1.3.6.1.4.1.14817.7.3.1.2.140 | not-accessible | current | |
| aprisaXEFXOControlTableEntry OBJECT-TYPE Entries for FXO table. | 1.3.6.1.4.1.14817.7.3.1.2.140.1 | not-accessible | current | |
| aprisaXEFXOControlSlotIndex OBJECT-TYPE Slot index for FXO Control table. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEFXOSPMBandwidth OBJECT-TYPE Set the spm detector bandwidth to 1.5%, 3.5%, 5.5% or 7.5%. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.2 | INTEGER {perc15(0), perc35(1), perc55(2), perc75(3)} | read-write | current |
| aprisaXEFXOSPMFrequency OBJECT-TYPE Set the spm detector frequency to 12kHz or 16kHz. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.3 | INTEGER {khz12(0), khz16(1)} | read-write | current |
| aprisaXEFXOSPMLevel OBJECT-TYPE Set the spm detector level 0 to 27 dB. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.4 | AprisaXEFXSPMLevel | read-write | current |
| aprisaXEFXOCasMode OBJECT-TYPE Set the CAS mode to XE,SE or 4Wire compatible. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.5 | INTEGER {casxe(0), casse(1), cas4w(2)} | read-write | current |
| aprisaXEFXOCasSignal OBJECT-TYPE Set the CAS signal to normal or invert. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.6 | AprisaXESignalState | read-write | obsolete |
| aprisaXEFXOPCMLaw OBJECT-TYPE Set the PCM law to A-law or u-law. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.7 | AprisaXEPcmLaw | read-write | current |
| aprisaXEFXOOnHookSpeed OBJECT-TYPE Set the on hook speed to fast, medium or slow. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.8 | INTEGER {ohsFast(0), ohsMedium(1), ohsSlow(2)} | read-write | current |
| aprisaXEFXORingerImpedance OBJECT-TYPE Set the ringer impedance to high or synthesized. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.9 | INTEGER {rzHigh(0), rxSynthesized(1)} | read-write | current |
| aprisaXEFXORingerThreshold OBJECT-TYPE Set the ringer threshold to low, medium or high. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.10 | INTEGER {rtLow(0), rtMedium(1), rtHigh(2)} | read-write | current |
| aprisaXEFXOLoopCurrentLimit OBJECT-TYPE Set the loop current limiter to off or on. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.11 | INTEGER {ilimOff(0), ilimOn(1)} | read-write | current |
| aprisaXEFXOMinLoopCurrent OBJECT-TYPE Set the min loop current to low, medium or high. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.12 | INTEGER {miniLow(0), miniMedium(1), miniHigh(2)} | read-write | current |
| aprisaXEFXOTipRingVoltage OBJECT-TYPE Set the tip ring voltage to low, medium or high. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.13 | INTEGER {dcvLow(0), dcvMedium(1), dcvHigh(2)} | read-write | current |
| aprisaXEFXOLineImpedance OBJECT-TYPE Set the line impedance to 600 Ohms, 900 Ohms, 600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF, TN12 - 220 Ohms + (820 Ohms || 120 nF), TBR21 - 270 Ohms + (750 Ohms || 150 nF), BT3 - 370 Ohms + (620 Ohms || 310 nF), BT Network - 320 Ohms + (1050 Ohms || 210 nF), China - 200 Ohms + (680 Ohms || 100 nF) | 1.3.6.1.4.1.14817.7.3.1.2.140.1.14 | INTEGER {acim0(0), acim1(1), acim11(2), acim13(3), acim3(4), acim2(5), acim4(6), acim9(7), acim10(8)} | read-write | current |
| aprisaXEFXOLineReversal OBJECT-TYPE Set the line reversal on/off. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.15 | INTEGER {fxoLineRevOn(0), fxoLineRevOff(1)} | read-write | obsolete |
| aprisaXEFXOABitFault OBJECT-TYPE Set the CAS A fault bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.16 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXOBBitRing OBJECT-TYPE Set the CAS B ring bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.17 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXOCBitBilling OBJECT-TYPE Set the CAS C billing bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.18 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXODBitReversals OBJECT-TYPE Set the CAS D reversals bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.19 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXOEchoCanceller OBJECT-TYPE Set the echo canceller to off, on or auto. The reserved values are for internal use only and cannot be set via SNMP. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.20 | INTEGER {fxoEchoCancellerOff(0), fxoEchoCancellerOn(1), fxoEchoCancellerAutoG164(2), fxoEchoCancellerAutoG165(3), fxoEchoCancellerReserved1(4), fxoEchoCancellerReserved2(5), fxoEchoCancellerReserved3(6)} | read-write | current |
| aprisaXEFXOABitOffHook OBJECT-TYPE Set the CAS A off hook bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.140.1.21 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEBackplaneConnectionTable OBJECT-TYPE Table of AprisaXE Cross connections. | 1.3.6.1.4.1.14817.7.3.1.2.150 | not-accessible | current | |
| aprisaXEBackplaneConnectionTableEntry OBJECT-TYPE Table entries define a circuit carried ove a TDM bus. | 1.3.6.1.4.1.14817.7.3.1.2.150.1 | not-accessible | current | |
| aprisaXEBackplaneConnectionID OBJECT-TYPE Handle to associate circuits with backplane connections. | 1.3.6.1.4.1.14817.7.3.1.2.150.1.1 | AprisaXEConnectionID | read-write | current |
| aprisaXEBackplaneTdmBus OBJECT-TYPE TDM Bus to switch: busA - busD. | 1.3.6.1.4.1.14817.7.3.1.2.150.1.2 | AprisaXETdmBus | read-write | current |
| aprisaXEBackplaneStartBitPos OBJECT-TYPE Start bit position on the associated TDM bus (0 - 2047). | 1.3.6.1.4.1.14817.7.3.1.2.150.1.3 | INTEGER (0..2047) | read-write | current |
| aprisaXEBackplaneLength OBJECT-TYPE Number of bits to place on the backplane TDM bus (0 - 2047). | 1.3.6.1.4.1.14817.7.3.1.2.150.1.4 | INTEGER (0..2047) | read-write | current |
| aprisaXEBackplaneInterface OBJECT-TYPE The type of circuit this backplane connection is carrying. | 1.3.6.1.4.1.14817.7.3.1.2.150.1.5 | AprisaXEInterfaceCnxnType | read-write | current |
| aprisaXEAggregateConnectionTable OBJECT-TYPE Table of Aggregated backplane connections used for interfaces with further cross-connection capability. | 1.3.6.1.4.1.14817.7.3.1.2.160 | not-accessible | current | |
| aprisaXEAggregateConnectionTableEntry OBJECT-TYPE | 1.3.6.1.4.1.14817.7.3.1.2.160.1 | not-accessible | current | |
| aprisaXEAggregateBackplaneID OBJECT-TYPE Backplane Connection identifier. | 1.3.6.1.4.1.14817.7.3.1.2.160.1.1 | Integer32 | read-only | current |
| aprisaXEAggregateInterfaceID OBJECT-TYPE | 1.3.6.1.4.1.14817.7.3.1.2.160.1.2 | Integer32 | read-only | current |
| aprisaXEAggregateStartBitPos OBJECT-TYPE Start bit position of the data coming into the cross-connection device (SWITI) for this interface connection. | 1.3.6.1.4.1.14817.7.3.1.2.160.1.3 | INTEGER (0..2047) | read-only | current |
| aprisaXEAggregateLength OBJECT-TYPE Number of bits required for this interface connection. | 1.3.6.1.4.1.14817.7.3.1.2.160.1.4 | INTEGER (0..2047) | read-only | current |
| aprisaXEAggregateOffset OBJECT-TYPE Offset into the aggregate connection where this interface connection is placed. | 1.3.6.1.4.1.14817.7.3.1.2.160.1.5 | INTEGER (0..2047) | read-only | current |
| aprisaXEAggregateE1Port OBJECT-TYPE Port number associated with this connection. | 1.3.6.1.4.1.14817.7.3.1.2.160.1.6 | AprisaXEPortNumber | read-only | current |
| aprisaXEAggregateControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.170 | |||
| aprisaXEAggregateControlBackplaneID OBJECT-TYPE The backplane ID to add or delete. | 1.3.6.1.4.1.14817.7.3.1.2.170.1 | INTEGER (0..2047) | read-write | current |
| aprisaXEAggregateControlInterfaceID OBJECT-TYPE Aggregate connection identifier. | 1.3.6.1.4.1.14817.7.3.1.2.170.2 | INTEGER (0..2047) | read-write | current |
| aprisaXEAggregateControlStartBitPos OBJECT-TYPE Start bit position of the data coming into the cross-connection device (SWITI) for this interface connection. | 1.3.6.1.4.1.14817.7.3.1.2.170.3 | INTEGER (0..2047) | read-write | current |
| aprisaXEAggregateControlLength OBJECT-TYPE Number of bits required for this interface connection. | 1.3.6.1.4.1.14817.7.3.1.2.170.4 | INTEGER (0..2047) | read-write | current |
| aprisaXEAggregateControlOffset OBJECT-TYPE Offset into the aggregate connection where this interface connection is placed. | 1.3.6.1.4.1.14817.7.3.1.2.170.5 | INTEGER (0..2047) | read-write | current |
| aprisaXEAggregateControlCommand OBJECT-TYPE Command to send to act upon the rows in the Aggregate Connection table. | 1.3.6.1.4.1.14817.7.3.1.2.170.6 | INTEGER {noCommand(0), addCommand(1), deleteCommand(2)} | read-write | current |
| aprisaXEBackplaneControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.180 | |||
| aprisaXEBackplaneControlConnectionID OBJECT-TYPE The Backplane Connection ID to add or delete. | 1.3.6.1.4.1.14817.7.3.1.2.180.1 | AprisaXEConnectionID | read-write | current |
| aprisaXEBackplaneControlTdmBus OBJECT-TYPE TDM Bus to switch: busA - busD. | 1.3.6.1.4.1.14817.7.3.1.2.180.2 | AprisaXETdmBus | read-write | current |
| aprisaXEBackplaneControlStartBitPos OBJECT-TYPE Start bit position on the associated TDM bus (0 - 2047). | 1.3.6.1.4.1.14817.7.3.1.2.180.3 | INTEGER (0..2047) | read-write | current |
| aprisaXEBackplaneControlLength OBJECT-TYPE Number of bits to place on the backplane TDM bus (0 - 2048). | 1.3.6.1.4.1.14817.7.3.1.2.180.4 | INTEGER (0..2048) | read-write | current |
| aprisaXEBackplaneControlInterface OBJECT-TYPE The type of circuit this backplane connection is carrying. | 1.3.6.1.4.1.14817.7.3.1.2.180.5 | AprisaXEInterfaceCnxnType | read-write | current |
| aprisaXEBackplaneControlCommand OBJECT-TYPE Command to send to act upon rows in the Backplane Connection table. | 1.3.6.1.4.1.14817.7.3.1.2.180.6 | INTEGER {noCommand(0), addCommand(1), deleteCommand(2)} | read-write | current |
| aprisaXEFXSPortControlTable OBJECT-TYPE Port Control table for FXS. | 1.3.6.1.4.1.14817.7.3.1.2.190 | not-accessible | current | |
| aprisaXEFXSPortControlTableEntry OBJECT-TYPE Entries for FXS table. | 1.3.6.1.4.1.14817.7.3.1.2.190.1 | not-accessible | current | |
| aprisaXEFXSPortControlSlotIndex OBJECT-TYPE Slot index for FXS Control table. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEFXSPortIndex OBJECT-TYPE Port index for FXS Control table. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEFXSLoopback OBJECT-TYPE Loopback control on or off for ports. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.3 | FourRFLoopback | read-write | current |
| aprisaXEFXSAdpcmCompression OBJECT-TYPE ADPCM compression 16, 24, 32, 64 kbps or none. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.4 | AprisaXEAdpcmCompression | read-write | current |
| aprisaXEFXSRxGain OBJECT-TYPE Rx gain -9.5 dB to +3 dB in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.5 | INTEGER {fxsrxpos30(0), fxsrxpos25(1), fxsrxpos20(2), fxsrxpos15(3), fxsrxpos10(4), fxsrxpos05(5), fxsrxpos0(6), fxsrxneg05(7), fxsrxneg10(8), fxsrxneg15(9), fxsrxneg20(10), fxsrxneg25(11), fxsrxneg30(12), fxsrxneg35(13), fxsrxneg40(14), fxsrxneg45(15), fxsrxneg50(16), fxsrxneg55(17), fxsrxneg60(18), fxsrxneg65(19), fxsrxneg70(20), fxsrxneg75(21), fxsrxneg80(22), fxsrxneg85(23), fxsrxneg90(24), fxsrxneg95(25)} | read-write | obsolete |
| aprisaXEFXSTxGain OBJECT-TYPE Tx gain -3 dB to 9.5 dB in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.6 | INTEGER {fxstxpos95(0), fxstxpos90(1), fxstxpos85(2), fxstxpos80(3), fxstxpos75(4), fxstxpos70(5), fxstxpos65(6), fxstxpos60(7), fxstxpos55(8), fxstxpos50(9), fxstxpos45(10), fxstxpos40(11), fxstxpos35(12), fxstxpos30(13), fxstxpos25(14), fxstxpos20(15), fxstxpos15(16), fxstxpos10(17), fxstxpos05(18), fxstxpos0(19), fxstxneg05(20), fxstxneg10(21), fxstxneg15(22), fxstxneg20(23), fxstxneg25(24), fxstxneg30(25)} | read-write | obsolete |
| aprisaXEFXSConnectionID OBJECT-TYPE Associated cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.7 | AprisaXEConnectionID | read-write | current |
| aprisaXEFXSSignallingConnectionID OBJECT-TYPE Associated signalling cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.8 | AprisaXEConnectionID | read-write | current |
| aprisaXEFXSInputLevel OBJECT-TYPE Input Level -9.0 dBr to +3.0 dBr in half dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.9 | AprisaXEFXSInputLevel | read-write | current |
| aprisaXEFXSOutputLevel OBJECT-TYPE Output Level -9.5 dBr to +2.5 dBr in 0.5 dB steps. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.10 | AprisaXEFXSOutputLevel | read-write | current |
| aprisaXEFXSPathMute OBJECT-TYPE Applies DFXS Mute Function - No Mute, Mute Rx or Mute Tx. | 1.3.6.1.4.1.14817.7.3.1.2.190.1.11 | AprisaXEFXSPathMute | read-write | current |
| aprisaXEFXSControlTable OBJECT-TYPE Control table for FXS. | 1.3.6.1.4.1.14817.7.3.1.2.195 | not-accessible | current | |
| aprisaXEFXSControlTableEntry OBJECT-TYPE Entries for FXS table. | 1.3.6.1.4.1.14817.7.3.1.2.195.1 | not-accessible | current | |
| aprisaXEFXSControlSlotIndex OBJECT-TYPE Slot index for FXS Control table. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEFXSPCMLaw OBJECT-TYPE Set the PCM law to A-law or u-law. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.2 | AprisaXEPcmLaw | read-write | current |
| aprisaXEFXSEchoCanceller OBJECT-TYPE Set the echo canceller to on or off. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.3 | INTEGER {echoCancellerOff(0), echoCancellerOn(1)} | read-write | current |
| aprisaXEFXSBillingToneFrequency OBJECT-TYPE Set the billing tone generator frequency to 12kHz or 16kHz. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.4 | INTEGER {khz12(0), khz16(1)} | read-write | current |
| aprisaXEFXSBillingToneAmplitude OBJECT-TYPE Set the billing tone generator amplitude to 400mV, 300mV, 250mV, 200mV, 150mV, 100mV or 50mV. Note, that software release 7.3.x only supports 400mV, 300mV, 200mV and 100mV. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.5 | INTEGER {mv300(0), mv250(1), mv200(2), mv150(3), mv100(4), mv50(5), mv400(6)} | read-write | current |
| aprisaXEFXSBillingToneDecay OBJECT-TYPE Set the billing tone generator attack decay ramp to 0.2ms, 0.5ms, 1ms, 2ms, 5ms, 10ms or 20ms. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.6 | INTEGER {ms02(0), ms05(1), ms1(2), ms2(3), ms5(4), ms10(5), ms20(6)} | read-write | current |
| aprisaXEFXSRingerFrequency OBJECT-TYPE Set the ringer frequency to 17Hz, 25Hz or 50Hz. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.7 | INTEGER {hz17(0), hz25(1), hz50(2)} | read-write | current |
| aprisaXEFXSRingerAmplitude OBJECT-TYPE Set the ringer amplitude to 40 V RMS, 45 V RMS, 50 V RMS, 55 V RMS or 60 V RMS. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.8 | INTEGER {vrms40(0), vrms45(1), vrms50(2), vrms55(3), vrms60(4)} | read-write | current |
| aprisaXEFXSLineImpedance OBJECT-TYPE Set the subscriber line impedance to 600 Ohms, 900 Ohms, 600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF, TN12 - 220 Ohms + (820 Ohms || 120 nF), TBR21 - 270 Ohms + (750 Ohms || 150 nF), BT3 - 370 Ohms + (620 Ohms || 310 nF) | 1.3.6.1.4.1.14817.7.3.1.2.195.1.9 | INTEGER {lineImpd1(0), lineImpd2(1), lineImpd3(2), lineImpd4(3), lineImpd5(4), lineImpd6(5), lineImpd7(6)} | read-write | current |
| aprisaXEFXSCasMode OBJECT-TYPE Set the CAS mode to XE,SE or 4Wire compatible. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.10 | INTEGER {casxe(0), casse(1), cas4w(2)} | read-write | current |
| aprisaXEFXSCasSignal OBJECT-TYPE Set the CAS signal to normal or invert. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.11 | AprisaXESignalState | read-write | obsolete |
| aprisaXEFXSTransHybridBalance OBJECT-TYPE Set the trans hybrid balance to 4.08dB, 2.5dB, 1.16dB, 0dB, -1.02dB, -1.94dB, -2.77dB, Off | 1.3.6.1.4.1.14817.7.3.1.2.195.1.12 | INTEGER {transHybridBal1(0), transHybridBal2(1), transHybridBal3(2), transHybridBal4(3), transHybridBal5(4), transHybridBal6(5), transHybridBal7(6), transHybridBal8(7)} | read-write | current |
| aprisaXEFXSLineReversal OBJECT-TYPE Set the line reversal on/off. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.13 | INTEGER {fxsLineRevOn(0), fxsLineRevOff(1)} | read-write | obsolete |
| aprisaXEFXSCalibrate OBJECT-TYPE Recalibrate the card yes/no. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.14 | INTEGER {fxsCalibrateNo(0), fxsCalibrateYes(1)} | read-write | current |
| aprisaXEFXSABitFault OBJECT-TYPE Set the CAS A fault bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.15 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXSBBitRing OBJECT-TYPE Set the CAS B ring bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.16 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXSCBitBilling OBJECT-TYPE Set the CAS C billing bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.17 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXSDBitReversals OBJECT-TYPE Set the CAS D reversals bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.18 | AprisaXE2WireSignalState | read-write | current |
| aprisaXEFXSLoopParameters OBJECT-TYPE Set the loop parameters to 'default' or 'Telkom SA Limited'. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.19 | INTEGER {fxsLoopParamDefault(0), fxsLoopParamTelkomSA(1)} | read-write | current |
| aprisaXEFXSABitOffHook OBJECT-TYPE Set the CAS A off hook bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted. | 1.3.6.1.4.1.14817.7.3.1.2.195.1.20 | AprisaXE2WireSignalState | read-write | current |
| aprisaXECrossConnectControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.200 | |||
| aprisaXECrossConnectControlCommand OBJECT-TYPE Command to send to delete all current cross-connections or to activate a new set of cross-connections. | 1.3.6.1.4.1.14817.7.3.1.2.200.1 | INTEGER {noCommand(0), deleteCommand(1), activateCommand(2)} | read-write | current |
| aprisaXEMotherboardExtendedModeCapable OBJECT-TYPE Allows the cross connect application to determine whether to stripe cross connections or not. | 1.3.6.1.4.1.14817.7.3.1.2.200.2 | INTEGER {extModeNo(0), extModeYes(1)} | read-only | current |
| aprisaXEEthernetActivationStatus OBJECT-TYPE Ethernet activation status i.e activated, failed or currently busy activating. | 1.3.6.1.4.1.14817.7.3.1.2.200.3 | AprisaXECCActivationStatus | read-only | current |
| aprisaXECCActivationStatusTable OBJECT-TYPE CC Activation status table. | 1.3.6.1.4.1.14817.7.3.1.2.202 | not-accessible | current | |
| aprisaXECCActivationStatusTableEntry OBJECT-TYPE Entries for CC Activation status table. | 1.3.6.1.4.1.14817.7.3.1.2.202.1 | not-accessible | current | |
| aprisaXECCActivationStatusSlotIndex OBJECT-TYPE Slot index for CC Activation Status table. | 1.3.6.1.4.1.14817.7.3.1.2.202.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXECCActivationStatus OBJECT-TYPE Cross-connect activation status i.e activated, failed or currently busy activating. | 1.3.6.1.4.1.14817.7.3.1.2.202.1.2 | AprisaXECCActivationStatus | read-only | current |
| aprisaXEHSSControlTable OBJECT-TYPE Control table for HSS. | 1.3.6.1.4.1.14817.7.3.1.2.207 | not-accessible | current | |
| aprisaXEHSSControlTableEntry OBJECT-TYPE Entries for HSS table. | 1.3.6.1.4.1.14817.7.3.1.2.207.1 | not-accessible | current | |
| aprisaXEHSSControlSlotIndex OBJECT-TYPE Slot index for HSS Control Table. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEHSSConnectionID OBJECT-TYPE Backplane Connection ID for data connection. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.2 | AprisaXEConnectionID | read-write | current |
| aprisaXEHSSSignallingID OBJECT-TYPE Backplane connection ID for signalling/control connection. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.3 | AprisaXEConnectionID | read-write | current |
| aprisaXEHSSEquipmentMode OBJECT-TYPE Terminal Equipment mode, DCE or DTE, this is a direct reflection of the equipment mode based on the type of cable currently connected. The value is not defined if no cable is attached. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.4 | AprisaXESerialEquipmentMode | read-only | current |
| aprisaXEHSSLoopback OBJECT-TYPE Interface loopback control. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.5 | FourRFLoopback | read-write | current |
| aprisaXEHSSNetworkClockSource OBJECT-TYPE Controls whether the port drive the clock source or not. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.6 | FourRFNetworkClockSelect | read-write | current |
| aprisaXEHSSSerialBaudRate OBJECT-TYPE Serial Baud rate where 1 = 8kbps and 256 = 2Mbps. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.7 | INTEGER (1..256) | read-write | current |
| aprisaXEHSSV110BaudRate OBJECT-TYPE V110 baud rate. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.8 | INTEGER {v110-600(0), v110-1200(1), v110-2400(2), v110-4800(3), v110-7200(4), v110-9600(5), v110-12000(6), v110-14400(7), v110-19200(8), v110-24000(9), v110-28800(10), v110-38400(11)} | read-write | current |
| aprisaXEHSSSendHandshakingMode OBJECT-TYPE Select 1 of 8 RTS/CTS modes of operation. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.9 | INTEGER {rts-ctsOff(0), rts-ctsOn(1), rts-ctsCarrier(2), rts-ctsCarrierRemote(3), rts-ctsCarrierLocalDCD(4), rts-ctsCarrierLocalRTS(5), rts-ctsCarrierLocalRTS1ms(6), rts-ctsCarrierLocalRTS24ms(7)} | read-write | current |
| aprisaXEHSSDataReadyMode OBJECT-TYPE Select 1 of 8 DSR/DTR modes. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.10 | INTEGER {dsr-dtrOff(0), dsr-dtrOn(1), dsr-dtrCarrier(2), dsr-dtrCarrierRemote(3)} | read-write | current |
| aprisaXEHSSCarrierDetectMode OBJECT-TYPE Select 1 of 4 DCD modes. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.11 | INTEGER {dcdOff(0), dcdOn(1), dcdCarrierRemoteDCD(2), dcdCarrierLocalDTR(3)} | read-write | current |
| aprisaXEHSSClockSelection OBJECT-TYPE Select the clock mode internal to the HSS traffic path. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.12 | INTEGER {hssClockInternal(0), hssClockXTxC(1), hssClockTxC(2), hssClockOverhead(3), hssClockNoOverhead(4), hssClockXTxC-RxC(5), hssClockXTxCNoOverhead(6)} | read-write | current |
| aprisaXEHSSXTxCEnabled OBJECT-TYPE Select whether XTxC generation is enabled or disabled for the port. The default is enabled. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.13 | INTEGER {hssxTxCEnabled(0), hssxTxCDisabled(1)} | read-write | current |
| aprisaXEHSSSerialMode OBJECT-TYPE Indicates the type of serial interface cable is connected to the HSS port. | 1.3.6.1.4.1.14817.7.3.1.2.207.1.14 | AprisaXEHssSerialMode | read-only | current |
| aprisaXEV24PortControlTable OBJECT-TYPE Port Control table for V24. | 1.3.6.1.4.1.14817.7.3.1.2.210 | not-accessible | current | |
| aprisaXEV24PortControlTableEntry OBJECT-TYPE Entries for V24 table. | 1.3.6.1.4.1.14817.7.3.1.2.210.1 | not-accessible | current | |
| aprisaXEV24PortControlSlotIndex OBJECT-TYPE Slot index for V24 Control table. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEV24PortIndex OBJECT-TYPE Port index for V24 Control table. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEV24BaudRate OBJECT-TYPE Baud Rate from 300 baud to 115200 baud. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.3 | INTEGER {v24-300(0), v24-600(1), v24-1200(2), v24-2400(3), v24-4800(4), v24-7200(5), v24-9600(6), v24-12800(7), v24-14400(8), v24-19200(9), v24-23040(10), v24-28800(11), v24-38400(12), v24-57600(13), v24-115200(14)} | read-write | current |
| aprisaXEV24Loopback OBJECT-TYPE Loopback control on or off for ports. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.4 | FourRFLoopback | read-write | current |
| aprisaXEV24DataBits OBJECT-TYPE No of data bits used, 7 or 8. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.5 | INTEGER {databits7(0), databits8(1)} | read-write | current |
| aprisaXEV24StopBits OBJECT-TYPE No of stop bits used, 1 or 2. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.6 | INTEGER {stopbits1(0), stopbits2(1)} | read-write | current |
| aprisaXEV24ParityBits OBJECT-TYPE No of parity bits used, 0 or 1. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.7 | INTEGER {paritybits0(0), paritybits1(1)} | read-write | current |
| aprisaXEV24ConnectionID OBJECT-TYPE Associated cross-connect Backplane Connection ID. | 1.3.6.1.4.1.14817.7.3.1.2.210.1.8 | AprisaXEConnectionID | read-write | current |
| aprisaXEDualJetBoardTable OBJECT-TYPE Table of Dual E1 card specific configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.220 | not-accessible | current | |
| aprisaXEDualJetBoardEntry OBJECT-TYPE Dual E1 configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.220.1 | not-accessible | current | |
| aprisaXEDualJetBoardTableIndex OBJECT-TYPE Dual E1 board indexed by slot. | 1.3.6.1.4.1.14817.7.3.1.2.220.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEDualJetPortTable OBJECT-TYPE Table based on slot and port of DualJet cards alarms. | 1.3.6.1.4.1.14817.7.3.1.2.221 | not-accessible | current | |
| aprisaXEDualJetPortEntry OBJECT-TYPE Dual E1 port alarms. | 1.3.6.1.4.1.14817.7.3.1.2.221.1 | not-accessible | current | |
| aprisaXEDualJetPortTableSlot OBJECT-TYPE Port table index based on slot number. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEDualJetPortTablePort OBJECT-TYPE Port table index based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEDualJetAISAlarmStatus OBJECT-TYPE AIS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.3 | FourRFAlarmStatus | read-only | current |
| aprisaXEDualJetAISAlarmSeverity OBJECT-TYPE AIS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.4 | FourRFAlarmSeverity | read-only | current |
| aprisaXEDualJetAISAlarmEnabled OBJECT-TYPE AIS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.5 | FourRFAlarmEnabled | read-only | current |
| aprisaXEDualJetLOSAlarmStatus OBJECT-TYPE LOS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.6 | FourRFAlarmStatus | read-only | current |
| aprisaXEDualJetLOSAlarmSeverity OBJECT-TYPE LOS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.7 | FourRFAlarmSeverity | read-only | current |
| aprisaXEDualJetLOSAlarmEnabled OBJECT-TYPE LOS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.221.1.8 | FourRFAlarmEnabled | read-only | current |
| aprisaXEDualJetIFConfigTable OBJECT-TYPE Switch data table which describes the allocation of user data on to the TDM busses. | 1.3.6.1.4.1.14817.7.3.1.2.222 | not-accessible | current | |
| aprisaXEDualJetIFConfigEntry OBJECT-TYPE Dual JET config data. | 1.3.6.1.4.1.14817.7.3.1.2.222.1 | not-accessible | current | |
| aprisaXEDualJetIFConfigSlotIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEDualJetIFConfigPortIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXEDualJetTrafficType OBJECT-TYPE Controls the traffic type on a Dual JET port. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.3 | AprisaXEQuadJetTrafficType | read-write | current |
| aprisaXEDualJetLoopback OBJECT-TYPE Controls the traffic loopback on a Dual JET port. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.4 | FourRFLoopback | read-write | obsolete |
| aprisaXEDualJetLineEncoding OBJECT-TYPE Controls the line encoding, the default is HDB3 for E1, B8ZS for T1. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.5 | AprisaXEQuadJetLineEncoding | read-write | current |
| aprisaXEDualJetPcmMode OBJECT-TYPE Controls the PCM mode, PCM31 or PCM30C. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.6 | AprisaXEPcmMode | read-write | current |
| aprisaXEDualJetClockSource OBJECT-TYPE Controls whether the port drives the clock soure or not. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.7 | FourRFNetworkClockSelect | read-write | current |
| aprisaXEDualJetLineRadioLoopback OBJECT-TYPE This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.8 | AprisaXEQuadJetLoopbacks | read-write | current |
| aprisaXEDualJetTxWaveFormShaper OBJECT-TYPE This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft. | 1.3.6.1.4.1.14817.7.3.1.2.222.1.9 | AprisaXEQuadJetWaveFormShapers | read-write | current |
| aprisaXESingleJetBoardTable OBJECT-TYPE Table of Single E1 card specific configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.225 | not-accessible | current | |
| aprisaXESingleJetBoardEntry OBJECT-TYPE Single E1 configuration details. | 1.3.6.1.4.1.14817.7.3.1.2.225.1 | not-accessible | current | |
| aprisaXESingleJetBoardTableIndex OBJECT-TYPE Single E1 board indexed by slot. | 1.3.6.1.4.1.14817.7.3.1.2.225.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXESingleJetPortTable OBJECT-TYPE Table based on slot and port of SingleJet cards alarms. | 1.3.6.1.4.1.14817.7.3.1.2.226 | not-accessible | current | |
| aprisaXESingleJetPortEntry OBJECT-TYPE Single E1 port alarms. | 1.3.6.1.4.1.14817.7.3.1.2.226.1 | not-accessible | current | |
| aprisaXESingleJetPortTableSlot OBJECT-TYPE Port table index based on slot number. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXESingleJetPortTablePort OBJECT-TYPE Port table index based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXESingleJetAISAlarmStatus OBJECT-TYPE AIS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.3 | FourRFAlarmStatus | read-only | current |
| aprisaXESingleJetAISAlarmSeverity OBJECT-TYPE AIS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.4 | FourRFAlarmSeverity | read-only | current |
| aprisaXESingleJetAISAlarmEnabled OBJECT-TYPE AIS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.5 | FourRFAlarmEnabled | read-only | current |
| aprisaXESingleJetLOSAlarmStatus OBJECT-TYPE LOS alarm status. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.6 | FourRFAlarmStatus | read-only | current |
| aprisaXESingleJetLOSAlarmSeverity OBJECT-TYPE LOS alarm severity. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.7 | FourRFAlarmSeverity | read-only | current |
| aprisaXESingleJetLOSAlarmEnabled OBJECT-TYPE LOS alarm enabled or disabled. | 1.3.6.1.4.1.14817.7.3.1.2.226.1.8 | FourRFAlarmEnabled | read-only | current |
| aprisaXESingleJetIFConfigTable OBJECT-TYPE Switch data table which describes the allocation of user data on to the TDM busses. | 1.3.6.1.4.1.14817.7.3.1.2.227 | not-accessible | current | |
| aprisaXESingleJetIFConfigEntry OBJECT-TYPE Single JET config data. | 1.3.6.1.4.1.14817.7.3.1.2.227.1 | not-accessible | current | |
| aprisaXESingleJetIFConfigSlotIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXESingleJetIFConfigPortIndex OBJECT-TYPE Index to the port table based on port number. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.2 | AprisaXEPortNumber | read-only | current |
| aprisaXESingleJetTrafficType OBJECT-TYPE Controls the traffic type on a Single JET port. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.3 | AprisaXEQuadJetTrafficType | read-write | current |
| aprisaXESingleJetLoopback OBJECT-TYPE Controls the traffic loopback on a Single JET port. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.4 | FourRFLoopback | read-write | obsolete |
| aprisaXESingleJetLineEncoding OBJECT-TYPE Controls the line encoding, the default is HDB3 for E1, B8ZS for T1. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.5 | AprisaXEQuadJetLineEncoding | read-write | current |
| aprisaXESingleJetPcmMode OBJECT-TYPE Controls the PCM mode, PCM31 or PCM30C. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.6 | AprisaXEPcmMode | read-write | current |
| aprisaXESingleJetClockSource OBJECT-TYPE Controls whether the port drives the clock soure or not. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.7 | FourRFNetworkClockSelect | read-write | current |
| aprisaXESingleJetLineRadioLoopback OBJECT-TYPE This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.8 | AprisaXEQuadJetLoopbacks | read-write | current |
| aprisaXESingleJetTxWaveFormShaper OBJECT-TYPE This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft. | 1.3.6.1.4.1.14817.7.3.1.2.227.1.9 | AprisaXEQuadJetWaveFormShapers | read-write | current |
| aprisaXEPSCControlTable OBJECT-TYPE Control table for PSC. | 1.3.6.1.4.1.14817.7.3.1.2.230 | not-accessible | current | |
| aprisaXEPSCControlTableEntry OBJECT-TYPE Entries for PSC table. | 1.3.6.1.4.1.14817.7.3.1.2.230.1 | not-accessible | current | |
| aprisaXEPSCControlSlotIndex OBJECT-TYPE Slot index for PSC Control Table. | 1.3.6.1.4.1.14817.7.3.1.2.230.1.1 | AprisaXESlotNumber | read-only | current |
| aprisaXEPSCActiveRadio OBJECT-TYPE Indicates the reception mode of the PSC. | 1.3.6.1.4.1.14817.7.3.1.2.230.1.2 | AprisaXEPSCActiveRadio | read-write | current |
| aprisaXEPSCActiveTx OBJECT-TYPE Indicates the currently active transmitter. | 1.3.6.1.4.1.14817.7.3.1.2.230.1.3 | AprisaXEPSCActiveTx | read-only | current |
| aprisaXEPSCDemodAlignmentStatusPSC OBJECT-TYPE Status of the demodulator alignment on the PSC. | 1.3.6.1.4.1.14817.7.3.1.2.230.1.4 | FourRFAlarmStatus | read-only | current |
| aprisaXEPSCDemodAlignmentStatusPIC OBJECT-TYPE Status of the demodulator alignment on the PIC. | 1.3.6.1.4.1.14817.7.3.1.2.230.1.5 | FourRFAlarmStatus | read-only | current |
| aprisaXEHSDParameterCompare OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.235 | |||
| aprisaXEHSDParameterMismatch OBJECT-TYPE If there is a parameter (OID) mismatch between Radio A and Radio B | 1.3.6.1.4.1.14817.7.3.1.2.235.1 | FourRFAlarmStatus | read-only | current |
| aprisaXEHSDParameterCompareChecking OBJECT-TYPE Enables/disables HSD paramter compare checking between Radio A and Radio B | 1.3.6.1.4.1.14817.7.3.1.2.235.2 | INTEGER {off(0), on(1)} | read-write | current |
| aprisaXESoftwareUpgradeControl OBJECT-IDENTITY | 1.3.6.1.4.1.14817.7.3.1.2.300 | |||
| aprisaXESoftwareUpgradeVersion OBJECT-TYPE New software version details of the form x_y_z. | 1.3.6.1.4.1.14817.7.3.1.2.300.1 | DisplayString (SIZE(0..16)) | read-write | current |
| aprisaXESoftwareUpgradeCommand OBJECT-TYPE Command used to instigate a software upgrade. | 1.3.6.1.4.1.14817.7.3.1.2.300.2 | INTEGER {none(0), upgrade(1)} | read-write | current |
| aprisaXESoftwareUpgradeResult OBJECT-TYPE Status of a software upgrade, this will have to be polled to follow the upload progress. | 1.3.6.1.4.1.14817.7.3.1.2.300.3 | FourRFProcessResultType | read-only | current |
| aprisaXEEvents OBJECT-IDENTITY The root of the OID sub-tree for the AprisaXE product events. | 1.3.6.1.4.1.14817.7.3.1.3 | current | ||
| aprisaXEEventsV2 OBJECT-IDENTITY The AprisaXE product events, ensures SNMPv1 compatibility. | 1.3.6.1.4.1.14817.7.3.1.3.0 | current | ||
| aprisaXETestObjects OBJECT-IDENTITY The root of the OID sub-tree for the AprisaXE test objects. | 1.3.6.1.4.1.14817.7.3.1.4 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| aprisaXETerminalGroup OBJECT-GROUP The AprisaXE terminal settings group. | 1.3.6.1.4.1.14817.7.3.1.1.1 | current |
| aprisaXEPerformanceGroup OBJECT-GROUP The AprisaXE terminal performance group. | 1.3.6.1.4.1.14817.7.3.1.1.6 | current |
| aprisaXEExternalAlarm1Group OBJECT-GROUP The AprisaXE first external alarm input group. | 1.3.6.1.4.1.14817.7.3.1.1.11 | current |
| aprisaXEExternalAlarmOutputOneGroup OBJECT-GROUP The AprisaXE first external alarm output group. | 1.3.6.1.4.1.14817.7.3.1.1.12 | current |
| aprisaXEExternalAlarmOutputTwoGroup OBJECT-GROUP The AprisaXE second external alarm output group. | 1.3.6.1.4.1.14817.7.3.1.1.13 | current |
| aprisaXEExternalAlarmOutputThreeGroup OBJECT-GROUP The AprisaXE third external alarm output group. | 1.3.6.1.4.1.14817.7.3.1.1.14 | current |
| aprisaXEExternalAlarmOutputFourGroup OBJECT-GROUP The AprisaXE fourth external alarm output group. | 1.3.6.1.4.1.14817.7.3.1.1.15 | current |
| aprisaXEExternalAlarm2Group OBJECT-GROUP The AprisaXE second external alarm input group. | 1.3.6.1.4.1.14817.7.3.1.1.16 | current |
| aprisaXEExternalAlarmsGroup OBJECT-GROUP The AprisaXE general external alarm details group. | 1.3.6.1.4.1.14817.7.3.1.1.17 | current |
| aprisaXERemoteAlarmGroup OBJECT-GROUP The AprisaXE remote alarm status group. This group has been replaced by the now mappable external alarm output OIDs aprisaXEExternalAlarmOutputXXXGroup. | 1.3.6.1.4.1.14817.7.3.1.1.21 | obsolete |
| aprisaXEMHSBGroup OBJECT-GROUP The aprisaXE MHSB group. | 1.3.6.1.4.1.14817.7.3.1.1.23 | current |
| aprisaXEFanGroup OBJECT-GROUP The AprisaXE fan status group. | 1.3.6.1.4.1.14817.7.3.1.1.26 | current |
| aprisaXEAlarmControlGroup OBJECT-GROUP The AprisaXE alarm control group. | 1.3.6.1.4.1.14817.7.3.1.1.32 | current |
| aprisaXETransmitterGroup OBJECT-GROUP The AprisaXE transmitter settings group. | 1.3.6.1.4.1.14817.7.3.1.1.36 | current |
| aprisaXETReceiverGroup OBJECT-GROUP The AprisaXE Receiver settings group. | 1.3.6.1.4.1.14817.7.3.1.1.46 | current |
| aprisaXEModemGroup OBJECT-GROUP The AprisaXE Modem settings group. | 1.3.6.1.4.1.14817.7.3.1.1.53 | current |
| aprisaXEForwardPowerHiAlarmsGroup OBJECT-GROUP The AprisaXE forward power too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.56 | obsolete |
| aprisaXEForwardPowerLoAlarmsGroup OBJECT-GROUP The AprisaXE forward power low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.61 | obsolete |
| aprisaXEReversePowerHiAlarmsGroup OBJECT-GROUP The AprisaXE reverse power too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.66 | obsolete |
| aprisaXEReversePowerLoAlarmsGroup OBJECT-GROUP The AprisaXE reverse power too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.71 | obsolete |
| aprisaXETxPaTempAlarmsGroup OBJECT-GROUP The AprisaXE transmitter temperature too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.76 | obsolete |
| aprisaXETxPaTempWarnAlarmsGroup OBJECT-GROUP The AprisaXE transmitter temperature warning alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.81 | obsolete |
| aprisaXETxAgcHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter AGC too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.86 | obsolete |
| aprisaXETxAgcLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter AGC too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.91 | obsolete |
| aprisaXETxVtuneHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter VTUNE too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.96 | obsolete |
| aprisaXETxVtuneLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter VTUNE too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.101 | obsolete |
| aprisaXETx5VDigHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 5V digital voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.106 | obsolete |
| aprisaXETx5VDigLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 5V digital voltage too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.111 | obsolete |
| aprisaXETx7VRfHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 7V RF voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.116 | obsolete |
| aprisaXETx7VRfLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 7V RF voltage too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.121 | obsolete |
| aprisaXETx9VHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 9V voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.126 | obsolete |
| aprisaXETx9VLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 9V voltage too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.131 | obsolete |
| aprisaXETx11VHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 11V voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.136 | obsolete |
| aprisaXETx11VLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 11V voltage too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.141 | obsolete |
| aprisaXETx28VHiAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 28V voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.146 | obsolete |
| aprisaXETx28VLoAlarmsGroup OBJECT-GROUP The AprisaXE transmitter 28V voltage too low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.151 | obsolete |
| aprisaXEReturnLossHiAlarmsGroup OBJECT-GROUP The AprisaXE reverse power too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.152 | current |
| aprisaXETxSynthOutOfLockAlarmsGroup OBJECT-GROUP The AprisaXE TX Synth out of lock alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.153 | current |
| aprisaXERxSynthOutOfLockAlarmsGroup OBJECT-GROUP The AprisaXE Synth out of lock alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.161 | current |
| aprisaXERx12VAlarmsGroup OBJECT-GROUP The AprisaXE 12V supply alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.166 | current |
| aprisaXERx3V3HiAlarmsGroup OBJECT-GROUP The AprisaXE 3.3V supply high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.171 | obsolete |
| aprisaXERx3V3LoAlarmsGroup OBJECT-GROUP The AprisaXE 3.3V supply low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.176 | obsolete |
| aprisaXERx5VHiAlarmsGroup OBJECT-GROUP The AprisaXE 5V supply High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.181 | obsolete |
| aprisaXERx5VLoAlarmsGroup OBJECT-GROUP The AprisaXE 5V supply low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.186 | obsolete |
| aprisaXERx9VHiAlarmsGroup OBJECT-GROUP The AprisaXE 9V supply High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.191 | obsolete |
| aprisaXERx9VLoAlarmsGroup OBJECT-GROUP The AprisaXE 9V supply low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.196 | obsolete |
| aprisaXERxNeg1V5HiAlarmsGroup OBJECT-GROUP The AprisaXE Neg 1.5V supply High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.201 | obsolete |
| aprisaXERxNeg1V5LoAlarmsGroup OBJECT-GROUP The AprisaXE Neg 1.5V supply low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.206 | obsolete |
| aprisaXERxAgcHiAlarmsGroup OBJECT-GROUP The AprisaXE AGC high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.211 | obsolete |
| aprisaXERxAgcLoAlarmsGroup OBJECT-GROUP The AprisaXE AGC low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.216 | obsolete |
| aprisaXERxRssiHiAlarmsGroup OBJECT-GROUP The AprisaXE RSSI High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.221 | current |
| aprisaXERxRssiLoAlarmsGroup OBJECT-GROUP The AprisaXE RSSI low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.226 | current |
| aprisaXERxVtuneHiAlarmsGroup OBJECT-GROUP The AprisaXE Vtune High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.231 | obsolete |
| aprisaXERxVtuneLoAlarmsGroup OBJECT-GROUP The AprisaXE Vtune low alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.236 | obsolete |
| aprisaXERxEEAlarmsGroup OBJECT-GROUP The AprisaXE EEPROM alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.241 | current |
| aprisaXETxADCChZeroHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Zero voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.250 | current |
| aprisaXETxADCChZeroLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Zero voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.251 | current |
| aprisaXETxADCChOneHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch One voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.252 | current |
| aprisaXETxADCChOneLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch One voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.253 | current |
| aprisaXETxADCChTwoHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Two voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.254 | current |
| aprisaXETxADCChTwoLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Two voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.255 | current |
| aprisaXETxADCChThreeHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Three voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.256 | current |
| aprisaXETxADCChThreeLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Three voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.257 | current |
| aprisaXETxADCChFourHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Four voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.258 | current |
| aprisaXETxADCChFourLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Four voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.259 | current |
| aprisaXETxADCChFiveHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Five voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.260 | current |
| aprisaXETxADCChFiveLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Five voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.261 | current |
| aprisaXETxADCChSixHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Six voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.262 | current |
| aprisaXETxADCChSixLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Six voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.263 | current |
| aprisaXETxADCChSevenHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Seven voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.264 | current |
| aprisaXETxADCChSevenLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Seven voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.265 | current |
| aprisaXETxADCChEightHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Eight voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.266 | current |
| aprisaXETxADCChEightLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Eight voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.267 | current |
| aprisaXETxADCChNineHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Nine voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.268 | current |
| aprisaXETxADCChNineLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Nine voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.269 | current |
| aprisaXETxADCChTenHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Ten voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.270 | current |
| aprisaXETxADCChTenLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Ten voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.271 | current |
| aprisaXETxADCChElevenHiAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Eleven voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.272 | current |
| aprisaXETxADCChElevenLoAlarmsGroup OBJECT-GROUP The aprisaXETx transmitter ADC Ch Eleven voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.273 | current |
| aprisaXERxADCChZeroHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Zero voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.275 | current |
| aprisaXERxADCChZeroLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Zero voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.276 | current |
| aprisaXERxADCChOneHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch One voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.277 | current |
| aprisaXERxADCChOneLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch One voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.278 | current |
| aprisaXERxADCChTwoHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Two voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.279 | current |
| aprisaXERxADCChTwoLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Two voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.280 | current |
| aprisaXERxADCChThreeHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Three voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.281 | current |
| aprisaXERxADCChThreeLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Three voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.282 | current |
| aprisaXERxADCChFourHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Four voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.283 | current |
| aprisaXERxADCChFourLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Four voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.284 | current |
| aprisaXERxADCChFiveHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Five voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.285 | current |
| aprisaXERxADCChFiveLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Five voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.286 | current |
| aprisaXERxADCChSixHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Six voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.287 | current |
| aprisaXERxADCChSixLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Six voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.288 | current |
| aprisaXERxADCChSevenHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Seven voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.289 | current |
| aprisaXERxADCChSevenLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Seven voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.290 | current |
| aprisaXERxADCChEightHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Eight voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.291 | current |
| aprisaXERxADCChEightLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Eight voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.292 | current |
| aprisaXERxADCChNineHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Nine voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.293 | current |
| aprisaXERxADCChNineLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Nine voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.294 | current |
| aprisaXERxADCChTenHiAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Ten voltage too high alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.295 | current |
| aprisaXERxADCChTenLoAlarmsGroup OBJECT-GROUP The aprisaXERx receiver ADC Ch Ten voltage too High alarm group. | 1.3.6.1.4.1.14817.7.3.1.1.296 | current |
| aprisaXESoftwareUpgradeControlGroup OBJECT-GROUP The Aprisa XE software upgrade group. | 1.3.6.1.4.1.14817.7.3.1.1.300 | current |
| aprisaXEHSDParameterCompareGroup OBJECT-GROUP The AprisaXE HSD Parameter Comparison group. | 1.3.6.1.4.1.14817.7.3.1.1.305 | current |