MIBs Depot

APRISAXE-EVENTS-4RF

Registered at
1.3.6.1.4.1.14817.2.7
1.3.6.1.4.1.14817.7.3.1.2.1000
1.3.6.1.4.1.14817.7.3.1.3.1
Last updated
2007-04-30 00:00
Organization
www.4rf.com
Revisions
2007-04-30 00:00, 2004-11-30 03:34
Namespace
4rf
Source file
APRISAXE-EVENTS-4RF
Digest
sha256:0c618e68cf5c5cd96b3038b4793f07446ff1fc94b0e5c8c20c6cf565f65c5b85

Description

Event MIB for the AprisaXE project

Contact

postal: 4RF Communications Ltd 26 Glover Street Ngauranga PO Box 13-506 Wellington 6032 New Zealand phone: +64 4 499 6000 email: support@4rf.com

Imports

FromSymbols
APRISAXE-MIB-4RFaprisaXEEvents, aprisaXEObjects
APRISAXE-TC-4RFAprisaXEAlarmType, AprisaXECardType, AprisaXEDataStatus, AprisaXEPortNumber, AprisaXESlotNumber
COMMON-TC-4RFFourRFAlarmEnabled, FourRFAlarmPresent, FourRFAlarmSeverity, FourRFAlarmStatus, FourRFHardwareVersion, FourRFImageVersion
MIB-4RFfourRFModules
PRODUCTS-MIB-4RFfourRFAprisaXE
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

APRISAXE-EVENTS-4RF
APRISAXE-MIB-4RF
APRISAXE-TC-4RF
COMMON-TC-4RF
MIB-4RF
PRODUCTS-MIB-4RF
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
aprisaXEEventValues
OBJECT-IDENTITY
1.3.6.1.4.1.14817.7.3.1.2.1000
aprisaXEEventAlarmStatus
OBJECT-TYPE
The status of an alarm event.
1.3.6.1.4.1.14817.7.3.1.2.1000.1FourRFAlarmPresentaccessible-for-notifycurrent
aprisaXEEventAlarmSeverity
OBJECT-TYPE
The severity of the alarm.
1.3.6.1.4.1.14817.7.3.1.2.1000.2FourRFAlarmSeverityaccessible-for-notifycurrent
aprisaXEEventAlarmValue
OBJECT-TYPE
Indicatesthe current value.
1.3.6.1.4.1.14817.7.3.1.2.1000.3Integer32accessible-for-notifycurrent
aprisaXEEventAlarmThreshold
OBJECT-TYPE
Indicates the level at which the alarm was set.
1.3.6.1.4.1.14817.7.3.1.2.1000.4Integer32accessible-for-notifycurrent
aprisaXEEventAlarmType
OBJECT-TYPE
The alarm type.
1.3.6.1.4.1.14817.7.3.1.2.1000.5AprisaXEAlarmTypeaccessible-for-notifycurrent
aprisaXEEventCardExpected
OBJECT-TYPE
The type of MUX card expected in a slot.
1.3.6.1.4.1.14817.7.3.1.2.1000.6AprisaXECardTypeaccessible-for-notifycurrent
aprisaXEEventCardInstalled
OBJECT-TYPE
The type of MUX card found in a slot.
1.3.6.1.4.1.14817.7.3.1.2.1000.7AprisaXECardTypeaccessible-for-notifycurrent
aprisaXEEventCardSlot
OBJECT-TYPE
The slot containing the unexpected card.
1.3.6.1.4.1.14817.7.3.1.2.1000.8AprisaXESlotNumberaccessible-for-notifycurrent
aprisaXEEventCardStatus
OBJECT-TYPE
Indicates whether the alarm is present or has been cleared.
1.3.6.1.4.1.14817.7.3.1.2.1000.9FourRFAlarmPresentaccessible-for-notifycurrent
aprisaXEEventCardPort
OBJECT-TYPE
The port reporting the event.
1.3.6.1.4.1.14817.7.3.1.2.1000.10AprisaXEPortNumberaccessible-for-notifycurrent
aprisaXEEventCharacterisationStatus
OBJECT-TYPE
Indicates whether the characterisation is valid or invalid.
1.3.6.1.4.1.14817.7.3.1.2.1000.15AprisaXEDataStatusaccessible-for-notifycurrent
aprisaXEEventMibStatus
OBJECT-TYPE
Indicates whether the MIB is valid or invalid.
1.3.6.1.4.1.14817.7.3.1.2.1000.16AprisaXEDataStatusaccessible-for-notifycurrent
aprisaXELinkAlarmsEvents
OBJECT-IDENTITY
The events for the link alarms.
1.3.6.1.4.1.14817.7.3.1.3.1current
aprisaXELinkAlarmsEventsV2
OBJECT-IDENTITY
The SNMPv2 events for the link alarms.
1.3.6.1.4.1.14817.7.3.1.3.1.0current

Notifications

NameOIDStatus
aprisaXEThresholdAlarmEvent
NOTIFICATION-TYPE
Event indicating a change in state of a threshold alarm. It will be sent whenever the status of the alarm changes from noAlarm to alarmPresent and vice versa.
1.3.6.1.4.1.14817.7.3.1.3.1.0.1current
aprisaXERxSynthOutOfLockAlarmEvent
NOTIFICATION-TYPE
Event indicating a change in state of the Rx synthesizer out of lock alarm. It will be sent whenever the status of the alarm changes from noAlarm to alarmPresent and vice versa.
1.3.6.1.4.1.14817.7.3.1.3.1.0.10current
aprisaXEAlarmRxCDataEvent
NOTIFICATION-TYPE
Event indicating a change in state of the receiver characterisation data alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.11current
aprisaXEAlarmRx12VStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the Rx synthesizer out of lock alarm. It will be sent whenever the status of the alarm changes from noAlarm to alarmPresent and vice versa.
1.3.6.1.4.1.14817.7.3.1.3.1.0.12current
aprisaXEAlarmRxOffEvent
NOTIFICATION-TYPE
Event indicating a change in state of receiver, when it is turned on or off. It will be sent whenever the status of the alarm changes from noAlarm to alarmPresent and vice versa.
1.3.6.1.4.1.14817.7.3.1.3.1.0.13current
aprisaXEAlarmRxBadMibEvent
NOTIFICATION-TYPE
Event indicating a change in state of the receiver MIB data alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.14current
aprisaXEAlarmTxCDataEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter characterisation data alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.20current
aprisaXEAlarmTxSynthOutOfLockEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter synthesiser out of lock alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.21current
aprisaXEAlarmTx28VStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter 28V supply status alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.22current
aprisaXEAlarmTx11VStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter 11V supply status alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.23current
aprisaXEAlarmTx5VStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter 5V digital supply status alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.24current
aprisaXEAlarmTxAmplifierBalanceEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter amplifier balance status alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.25current
aprisaXEAlarmTxBadMibEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter MIB data alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.26current
aprisaXEAlarmTxNeg5VStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the transmitter Negative 5V digital supply status alarm.
1.3.6.1.4.1.14817.7.3.1.3.1.0.27current
aprisaXEModemSyncEvent
NOTIFICATION-TYPE
Event indicating a change in state of the modem lock.
1.3.6.1.4.1.14817.7.3.1.3.1.0.30current
aprisaXEModemTDMAlignmentEvent
NOTIFICATION-TYPE
Event indicating a change in state of the modem TDM alignment.
1.3.6.1.4.1.14817.7.3.1.3.1.0.31current
aprisaXEModemDemodAlignmentEvent
NOTIFICATION-TYPE
Event indicating a change in state of the modem demodulator alignment.
1.3.6.1.4.1.14817.7.3.1.3.1.0.32current
aprisaXEModemRefAStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the Ref A clock.
1.3.6.1.4.1.14817.7.3.1.3.1.0.33current
aprisaXEModemRefBStatusEvent
NOTIFICATION-TYPE
Event indicating a change in state of the Ref B clock.
1.3.6.1.4.1.14817.7.3.1.3.1.0.34current
aprisaXEModemUCEPresentEvent
NOTIFICATION-TYPE
Event indicating the presence of uncorrectable errors.
1.3.6.1.4.1.14817.7.3.1.3.1.0.35current
aprisaXEQuadE1LOSEvent
NOTIFICATION-TYPE
Event indicating a change in LOS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.40current
aprisaXEQuadE1AISEvent
NOTIFICATION-TYPE
Event indicating a change in AIS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.41current
aprisaXEQuadE1RAIEvent
NOTIFICATION-TYPE
Event indicating a change in RAI state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.42current
aprisaXEQuadE1RMAIEvent
NOTIFICATION-TYPE
Event indicating a change in RMAI state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.43current
aprisaXEQuadE1TS16AISEvent
NOTIFICATION-TYPE
Event indicating a change in TS16AIS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.44current
aprisaXEQuadE1TS16LOSEvent
NOTIFICATION-TYPE
Event indicating a change in TS16LOS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.45current
aprisaXEQuadE1LOFEvent
NOTIFICATION-TYPE
Event indicating a change in loss of frame state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.46current
aprisaXEFXOCodecOvldEvent
NOTIFICATION-TYPE
Event indicating a change in Codec Ovld state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.50current
aprisaXEFXOBillToneOvldEvent
NOTIFICATION-TYPE
Event indicating a change in Billing Tone Ovld state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.51current
aprisaXEFXOCurrentOvldEvent
NOTIFICATION-TYPE
Event indicating a change in Current Ovld state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.52current
aprisaXEFXOUnplugEvent
NOTIFICATION-TYPE
Event indicating a change in Unplug state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.53current
aprisaXEFXSCalibrateErrorEvent
NOTIFICATION-TYPE
Event indicating a common mode error during Pro-SLIC initialisation.
1.3.6.1.4.1.14817.7.3.1.3.1.0.60current
aprisaXEFXSDCDCErrorEvent
NOTIFICATION-TYPE
Event indicating a DC-DC converter error during Pro-SLIC initialisation
1.3.6.1.4.1.14817.7.3.1.3.1.0.61obsolete
aprisaXEFXSCASLockEvent
NOTIFICATION-TYPE
Event indicating the FPGA has not locked onto a CAS frame.
1.3.6.1.4.1.14817.7.3.1.3.1.0.62current
aprisaXEHSSTDMLockEvent
NOTIFICATION-TYPE
Event indicating an HSS TDM Lock error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.70current
aprisaXEHSS32MHzResetEvent
NOTIFICATION-TYPE
Event indicating a 32MHz clock reset error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.71current
aprisaXEHSSTDMResetEvent
NOTIFICATION-TYPE
Event indicating a TDM reset error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.72current
aprisaXEHSSPatternLossEvent
NOTIFICATION-TYPE
Event indicating a Pattern Loss error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.73current
aprisaXEHSSRxFifoFullEvent
NOTIFICATION-TYPE
Event indicating an Rx FIFO Full error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.74current
aprisaXEHSSRxFifoEmptyEvent
NOTIFICATION-TYPE
Event indicating an Rx FIFO Empty error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.75current
aprisaXEHSSTxFifoFullEvent
NOTIFICATION-TYPE
Event indicating a Tx FIFO Full error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.76current
aprisaXEHSSTxFifoEmptyEvent
NOTIFICATION-TYPE
Event indicating a Tx FIFO Empty error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.77current
aprisaXEHSSRxClockValidEvent
NOTIFICATION-TYPE
Event indicating an Rx Clock Valid error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.78current
aprisaXEHSSTxClockValidEvent
NOTIFICATION-TYPE
Event indicating a Tx Clock Valid error.
1.3.6.1.4.1.14817.7.3.1.3.1.0.79current
aprisaXEV24ControlLineLossEvent
NOTIFICATION-TYPE
Event indicating V24 control line aren't in sync.
1.3.6.1.4.1.14817.7.3.1.3.1.0.80current
aprisaXEUnexpectedCardEvent
NOTIFICATION-TYPE
Event indicating an mismatch between the MIB and the installed MUX cards. The radio will not operate correctly if the MIB and MUX cards do not match.
1.3.6.1.4.1.14817.7.3.1.3.1.0.100current
aprisaXECLKSyncEvent
NOTIFICATION-TYPE
Event indicating a change in state of the clock sync state.
1.3.6.1.4.1.14817.7.3.1.3.1.0.110current
aprisaXENetClkConfigEvent
NOTIFICATION-TYPE
Event indicating a change in state of the network clock config.
1.3.6.1.4.1.14817.7.3.1.3.1.0.111current
aprisaXECharacterisationEEFailEvent
NOTIFICATION-TYPE
Event indicating a failed read of characterisation data from EEPROM.
1.3.6.1.4.1.14817.7.3.1.3.1.0.120current
aprisaXEMibEEFailEvent
NOTIFICATION-TYPE
Event indicating a failed read of mib data from EEPROM.
1.3.6.1.4.1.14817.7.3.1.3.1.0.121current
aprisaXEMhsbSwitchToStandbyEvent
NOTIFICATION-TYPE
Event indicating a Monitored Hot Standby switch to Standby Event.
1.3.6.1.4.1.14817.7.3.1.3.1.0.130current
aprisaXEAlternateImageTableEvent
NOTIFICATION-TYPE
Event indicating an Alternate Image Table Event.
1.3.6.1.4.1.14817.7.3.1.3.1.0.131current
aprisaXEDefaultImageTableEvent
NOTIFICATION-TYPE
Event indicating a Default Image Table Event.
1.3.6.1.4.1.14817.7.3.1.3.1.0.132current
aprisaXEUploadFailEvent
NOTIFICATION-TYPE
Event indicating the failure of the previous upload.
1.3.6.1.4.1.14817.7.3.1.3.1.0.133current
aprisaXEPscDemuxAlignmentEvent
NOTIFICATION-TYPE
Event indicating a change in state of the PSC Demux alignment .
1.3.6.1.4.1.14817.7.3.1.3.1.0.140current
aprisaXEPscTDMAlignmentEvent
NOTIFICATION-TYPE
Event indicating a change in state of the PSC TDM alignment.
1.3.6.1.4.1.14817.7.3.1.3.1.0.141current
aprisaXEPscMuxAlignmentErrorEvent
NOTIFICATION-TYPE
Event indicating if the TDM mux loses alignment to the TDM bus.
1.3.6.1.4.1.14817.7.3.1.3.1.0.142current
aprisaXEPscCompanionTxFailEvent
NOTIFICATION-TYPE
Event indicating that the HRSD Companion transmitter has failed.
1.3.6.1.4.1.14817.7.3.1.3.1.0.143current
aprisaXEPscSoftwareOverrideEvent
NOTIFICATION-TYPE
Event indicating a software override of the PSC Mode Switch.
1.3.6.1.4.1.14817.7.3.1.3.1.0.144current
aprisaXEPscInvalidSwitchValueEvent
NOTIFICATION-TYPE
Event indicating that the PSC Mode Switch value is invalid.
1.3.6.1.4.1.14817.7.3.1.3.1.0.145current
aprisaXEDualE1LOSEvent
NOTIFICATION-TYPE
Event indicating a change in LOS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.150current
aprisaXEDualE1AISEvent
NOTIFICATION-TYPE
Event indicating a change in AIS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.151current
aprisaXESingleE1LOSEvent
NOTIFICATION-TYPE
Event indicating a change in LOS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.160current
aprisaXESingleE1AISEvent
NOTIFICATION-TYPE
Event indicating a change in AIS state for a port.
1.3.6.1.4.1.14817.7.3.1.3.1.0.161current
aprisaXEHrsdCompareOidEvent
NOTIFICATION-TYPE
Event indicating that an OID failed its comparison check.
1.3.6.1.4.1.14817.7.3.1.3.1.0.170current
aprisaXEHrsdCompanionLostEvent
NOTIFICATION-TYPE
Event indicating that the HRSD Companion Heartbeat is lost.
1.3.6.1.4.1.14817.7.3.1.3.1.0.171current