ACS-TRAP-MIB
- Registered at
- 1.3.6.1.4.1.10418
- Last updated
- 2024-10-01 00:00
- Organization
- Vertiv Co
- Revisions
- 2024-10-01 00:00, 2024-05-01 00:00, 2023-09-06 00:00, 2021-06-24 00:00, 2017-08-15 00:00
- Namespace
- avocent
- Source file
ACS-TRAP-MIB- Digest
sha256:c7c04ce01902370d9d6e33fc3b55fe539593fb921451c33f1c6753b606ebd96f
Description
This module defines the TRAP MIB extensions to acs products.
Contact
e-mail : support.avocent@vertivco.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ACS-TRAP-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.10418.17 | pm | PM-MIB |
| 1.3.6.1.4.1.10418.18 | dellrcsg2 | DELLRCSG2-TRAP-MIB |
| 1.3.6.1.4.1.10418.26 | acs |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| avocent OBJECT-IDENTITY | 1.3.6.1.4.1.10418 | |||
| acsTrap OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.0 | |||
| acsProducts OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.1 | |||
| acsManagement OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.2 | |||
| acsTrapObject OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.2.6 | |||
| acsTrapObjectUserName OBJECT-TYPE This object is sent in a trap to identify the name of the user for which the trap condition occurred. | 1.3.6.1.4.1.10418.26.2.6.1 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectDaemonName OBJECT-TYPE This object is sent in a trap to indicate the Daemon name that has started/stopped. | 1.3.6.1.4.1.10418.26.2.6.2 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectTargetUserName OBJECT-TYPE This object is sent in a trap to identify the name of the user for which the trap condition occurred. | 1.3.6.1.4.1.10418.26.2.6.3 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectFileName OBJECT-TYPE This object is sent in a trap to identify the name of the file that was used. | 1.3.6.1.4.1.10418.26.2.6.4 | OCTET STRING | accessible-for-notify | current |
| acsTrapFirmwareVersion OBJECT-TYPE This object is sent in a trap to identify current Firmware version. | 1.3.6.1.4.1.10418.26.2.6.5 | OCTET STRING | accessible-for-notify | current |
| acsTrapNewFirmwareVersion OBJECT-TYPE This object is sent in a trap to identify new Firmware version. | 1.3.6.1.4.1.10418.26.2.6.6 | OCTET STRING | accessible-for-notify | current |
| acsTrapFirmwareUpgradeResult OBJECT-TYPE This object is sent in a trap to identify the firmware upgrade result. | 1.3.6.1.4.1.10418.26.2.6.7 | INTEGER {imageUpgradeSuccess(1), imageUpgradeInternalError(2)} | accessible-for-notify | current |
| acsTrapObjectAlertIndex OBJECT-TYPE This object is sent in a trap to identify the alert string that matched in the alert message. | 1.3.6.1.4.1.10418.26.2.6.8 | Integer32 | accessible-for-notify | current |
| acsTrapObjectAlertMessage OBJECT-TYPE This object is sent in a trap to identify the line text where the alert string was detected. | 1.3.6.1.4.1.10418.26.2.6.9 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectAlertString OBJECT-TYPE This object is sent in a trap to identify the alert string that matched in the alert message. | 1.3.6.1.4.1.10418.26.2.6.10 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectSessionType OBJECT-TYPE This object is sent in a trap to identify type of Session for access to appliance. | 1.3.6.1.4.1.10418.26.2.6.11 | INTEGER {ssh(0), telnet(1), console(2), login(3), http(4), https(5), dsview(6), raw(7), modem(8)} | accessible-for-notify | current |
| acsTrapObjectSerialPortName OBJECT-TYPE This object is sent in a trap to identify the target Device by name - alias of the serial port. | 1.3.6.1.4.1.10418.26.2.6.12 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectSerialPortNumber OBJECT-TYPE This object is sent in a trap to identify which serial port number the trap condition occurred. | 1.3.6.1.4.1.10418.26.2.6.13 | Integer32 | accessible-for-notify | current |
| acsTrapObjectSerialSessionType OBJECT-TYPE This object is sent in a trap to identify type of Serial Session. | 1.3.6.1.4.1.10418.26.2.6.14 | INTEGER {cas-ssh(1), cas-telnet(2), cas-console(3), cas-raw(4), dial-in(5)} | accessible-for-notify | current |
| acsTrapObjectDataBufferSize OBJECT-TYPE This object is sent in a trap to identify current size of global buffer. | 1.3.6.1.4.1.10418.26.2.6.15 | Integer32 | accessible-for-notify | current |
| acsTrapObjectPduId OBJECT-TYPE This object is sent in a trap to identify the ID of the PDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.16 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduNumber OBJECT-TYPE This object is sent in a trap to identify the index of the PDU the trap condition occurred on. | 1.3.6.1.4.1.10418.26.2.6.17 | Integer32 | accessible-for-notify | current |
| acsTrapObjectPduSocket OBJECT-TYPE This object is sent in a trap to identify number of outlets of the PDU. | 1.3.6.1.4.1.10418.26.2.6.18 | Integer32 | accessible-for-notify | current |
| acsTrapObjectPduVendor OBJECT-TYPE This object is sent in a trap to identify the vendor of the IPDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.19 | INTEGER {cyclades(1), spc(2), serverTech(3), vertiv(4), raritan(5), apc(6), eaton(7), servertechpro2(8), geist(9), net-servertech(10), net-vertiv(11), net-avocent(12), net-eaton(13), net-raritan(14), net-apc(15), net-apc-rpdu(16), net-servertech-pro2(17), net-geist(18)} | accessible-for-notify | current |
| acsTrapObjectPduIdOld OBJECT-TYPE This object is sent in a trap to identify the old ID of the PDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.20 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduCurrentValue OBJECT-TYPE This object is sent in a trap to detected current value of the PDU. | 1.3.6.1.4.1.10418.26.2.6.22 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectSocketNumber OBJECT-TYPE This object is sent in a trap to identify outlet number the trap condition occurred on. | 1.3.6.1.4.1.10418.26.2.6.23 | Integer32 | accessible-for-notify | current |
| acsTrapObjectSocketName OBJECT-TYPE This object is sent in a trap to identify outlet name stored in the PM. | 1.3.6.1.4.1.10418.26.2.6.24 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectSocketOldName OBJECT-TYPE This object is sent in a trap to identify the old outlet name stored in the PM. | 1.3.6.1.4.1.10418.26.2.6.25 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectSerialSessionNumbers OBJECT-TYPE This object is sent in a trap to identify the number of sessions openned in the serial port. | 1.3.6.1.4.1.10418.26.2.6.26 | Integer32 | accessible-for-notify | current |
| acsTrapObjectCertExpirationTime OBJECT-TYPE This object is sent in a trap to identify the certificate expiration time. | 1.3.6.1.4.1.10418.26.2.6.28 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectCertificateFileName OBJECT-TYPE This object is sent in a trap to identify a certificate file name. | 1.3.6.1.4.1.10418.26.2.6.29 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectConnectionName OBJECT-TYPE This object is sent in a trap to identify the IPsec connection name. | 1.3.6.1.4.1.10418.26.2.6.30 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectConnectionReason OBJECT-TYPE This object is sent in a trap to identify the IPsec failure reason. | 1.3.6.1.4.1.10418.26.2.6.31 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduElementName OBJECT-TYPE This object is sent in a trap to identify the Element of the PDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.40 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduElementType OBJECT-TYPE This object is sent in a trap to identify the Element Type of the PDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.41 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectUpsId OBJECT-TYPE This object is sent in a trap to identify the ID of the UPS where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.42 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectUpsVendor OBJECT-TYPE This object is sent in a trap to identify the vendor of the UPS where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.43 | INTEGER {liebert-gxt4(1), net-liebert(2), liebert-gxt5(3)} | accessible-for-notify | current |
| acsTrapObjectUpsIdOld OBJECT-TYPE This object is sent in a trap to identify the old ID of the UPS where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.44 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectUpsBatteryTimeRemaining OBJECT-TYPE This object is sent in a trap to identify the estimated number of minutes of battery time remaining. | 1.3.6.1.4.1.10418.26.2.6.45 | Integer32 | accessible-for-notify | current |
| acsTrapObjectUpsOutletGroupNumber OBJECT-TYPE This object is sent in a trap to identify the UPS outlet group number the trap condition occurred on. | 1.3.6.1.4.1.10418.26.2.6.46 | Integer32 | accessible-for-notify | current |
| acsTrapObjectUpsOutletGroupName OBJECT-TYPE This object is sent in a trap to identify the UPS outlet group name. | 1.3.6.1.4.1.10418.26.2.6.47 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectTemperatureMaximumValue OBJECT-TYPE This object is sent in a trap to identify the maximum temperature value configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.100 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMaxThreshold OBJECT-TYPE This object is sent in a trap to identify the max temperature threshold configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.101 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMinimumValue OBJECT-TYPE This object is sent in a trap to identify the minimum temperature value configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.102 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMinThreshold OBJECT-TYPE This object is sent in a trap to identify the min temperature threshold configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.103 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureCurrent OBJECT-TYPE This object is sent in a trap to identify the current temperature. | 1.3.6.1.4.1.10418.26.2.6.104 | Integer32 | accessible-for-notify | current |
| acsTrapObjectPowerSupplyNumber OBJECT-TYPE This object is sent in a trap to identify the appliance power supply for which the trap condition occurred. | 1.3.6.1.4.1.10418.26.2.6.105 | Integer32 | accessible-for-notify | current |
| acsTrapObjectPowerSupplyOldState OBJECT-TYPE This object is sent in a trap to identify the old state of the power supply. | 1.3.6.1.4.1.10418.26.2.6.106 | INTEGER {powerSupplyOn(1), powerSupplyOff(2)} | accessible-for-notify | current |
| acsTrapObjectPowerSupplyNewState OBJECT-TYPE This object is sent in a trap to identify the new state of the power supply. | 1.3.6.1.4.1.10418.26.2.6.107 | INTEGER {powerSupplyOn(1), powerSupplyOff(2)} | accessible-for-notify | current |
| acsTrapObjectPlugDeviceName OBJECT-TYPE This object is sent in a trap to identify the device name used by the plugged device. | 1.3.6.1.4.1.10418.26.2.6.108 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPlugDeviceType OBJECT-TYPE This object is sent in a trap to identify the type of the plugged device. | 1.3.6.1.4.1.10418.26.2.6.109 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPlugDeviceInfo OBJECT-TYPE This object is sent in a trap to identify the info about plugged device. | 1.3.6.1.4.1.10418.26.2.6.110 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduFuseStatus OBJECT-TYPE This object is sent in a trap for blown fuse detection in the PDU. | 1.3.6.1.4.1.10418.26.2.6.112 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectServiceName OBJECT-TYPE This object is sent in a trap to indicate the Service name that is in FIPS or non-FIPS mode. | 1.3.6.1.4.1.10418.26.2.6.113 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectMd5Tag OBJECT-TYPE This object is sent in a trap to indicate that a new configuration Md5 was generated. | 1.3.6.1.4.1.10418.26.2.6.114 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectNetworkPrimary OBJECT-TYPE This object is sent in a trap to indicate the Primary Interface. | 1.3.6.1.4.1.10418.26.2.6.115 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectNetworkSecondary OBJECT-TYPE This object is sent in a trap to indicate the Secondary Interface. | 1.3.6.1.4.1.10418.26.2.6.116 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectApplianceSensorType OBJECT-TYPE This object is sent in a trap to indicate the sensor type. | 1.3.6.1.4.1.10418.26.2.6.117 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectApplianceSensorName OBJECT-TYPE This object is sent in a trap to indicate the sensor name. | 1.3.6.1.4.1.10418.26.2.6.118 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectApplianceSensorValue OBJECT-TYPE This object is sent in a trap to indicate the present sensor value. | 1.3.6.1.4.1.10418.26.2.6.119 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectTemperatureMaximumCpuValue OBJECT-TYPE This object is sent in a trap to identify the maximum CPU temperature value configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.120 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMaxCpuThreshold OBJECT-TYPE This object is sent in a trap to identify the max CPU temperature threshold configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.121 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMinimumCpuValue OBJECT-TYPE This object is sent in a trap to identify the minimum CPU temperature value configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.122 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureMinCpuThreshold OBJECT-TYPE This object is sent in a trap to identify the min CPU temperature threshold configured in the appliance. | 1.3.6.1.4.1.10418.26.2.6.123 | Integer32 | accessible-for-notify | current |
| acsTrapObjectTemperatureCpuCurrent OBJECT-TYPE This object is sent in a trap to identify the current CPU temperature. | 1.3.6.1.4.1.10418.26.2.6.124 | Integer32 | accessible-for-notify | current |
| acsTrapObjectCallerIdNumber OBJECT-TYPE This object is sent in a trap to identify the incoming Caller ID telephone number. | 1.3.6.1.4.1.10418.26.2.6.125 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectCallerIdName OBJECT-TYPE This object is sent in a trap to identify the incoming caller ID name. | 1.3.6.1.4.1.10418.26.2.6.126 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectModemDeviceName OBJECT-TYPE This object is sent in a trap to identify the device name used by the modem. | 1.3.6.1.4.1.10418.26.2.6.127 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectModemNetworkConnection OBJECT-TYPE This object is sent in a trap to identify the type of network the cellular modem is connected to. | 1.3.6.1.4.1.10418.26.2.6.128 | INTEGER {registeredHomeNetwork(1), registeredRoamingNetwork(2)} | accessible-for-notify | current |
| acsTrapObjectModemRegistrationFailReason OBJECT-TYPE This object is sent in a trap to identify the reason for the modem connection failure. | 1.3.6.1.4.1.10418.26.2.6.129 | INTEGER {notRegistered(0), searching(2), registrationDenied(3), unknown(4), waitingForPIN(6)} | accessible-for-notify | current |
| acsTrapObjectTaskName OBJECT-TYPE This object is sent in a trap to identify the scheduled task name. | 1.3.6.1.4.1.10418.26.2.6.130 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectTaskResult OBJECT-TYPE This object is sent in a trap to identify the scheduled task result. | 1.3.6.1.4.1.10418.26.2.6.131 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectModemStatus OBJECT-TYPE This object is sent in a trap to identify the status of the modem. | 1.3.6.1.4.1.10418.26.2.6.132 | OCTET STRING | accessible-for-notify | current |
| acsTrapObjectPduNewElementName OBJECT-TYPE This object is sent in a trap to identify the new element name of the PDU where the trap occurred. | 1.3.6.1.4.1.10418.26.2.6.133 | OCTET STRING | accessible-for-notify | current |
| acsconformance OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.15 | |||
| acsObjectGroups OBJECT-IDENTITY | 1.3.6.1.4.1.10418.26.15.1 |
Notifications
| Name | OID | Status |
|---|---|---|
| avctAcsRebootStartedTrap NOTIFICATION-TYPE ACS8000 is in process of rebooting. The name of the user who issued the command is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.1 | current |
| avctAcsDaemonStarted NOTIFICATION-TYPE This trap is generated when daemon in the appliance started. The daemon name is contained in acsTrapObjectDaemonName. The name of the user who start the daemon is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.2 | current |
| avctAcsDaemonStopped NOTIFICATION-TYPE This trap is generated when daemon in the appliance stopped. The daemon name is contained in acsTrapObjectDaemonName. The name of the user who stop the daemon is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.3 | current |
| avctAcsSessionTerminatedTrap NOTIFICATION-TYPE This trap is generated when one previous session is terminated by another user. The name of the user who terminated the session is contained in acsTrapObjectUserName. The name of the user who was terminated from the session is contained in acsTrapObjectTargetUserName. | 1.3.6.1.4.1.10418.26.0.4 | current |
| avctAcsConfigurationStoredTrap NOTIFICATION-TYPE This trap is generated when 'store backup configuration' command is successful. acsTrapObjectUserName is name of the user who executed the command. acsTrapObjectFileName is name of the file where the configuration was stored. | 1.3.6.1.4.1.10418.26.0.5 | current |
| avctAcsConfigurationRestoredTrap NOTIFICATION-TYPE This trap is generated when 'restore backup configuration' command is successful. acsTrapObjectUserName is name of the user who executed the command. acsTrapObjectFileName is name of the file used to restored the configuration. | 1.3.6.1.4.1.10418.26.0.6 | current |
| avctAcsExportFileTrap NOTIFICATION-TYPE This trap is generated when 'export file' command is successful. acsTrapObjectUserName is name of the user who executed the command. acsTrapObjectFileName is name of the file exported. | 1.3.6.1.4.1.10418.26.0.7 | current |
| avctAcsLocalUserAddedTrap NOTIFICATION-TYPE A new user has been added to the local user database. The name of the user who added the new user is contained in acsTrapObjectUserName. The name of the new user is contained in acsTrapObjectTargetUserName. | 1.3.6.1.4.1.10418.26.0.8 | current |
| avctAcsLocalUserDeletedTrap NOTIFICATION-TYPE A user has been deleted from the local user database. The name of the user who deleted the user is contained in acsTrapObjectUserName. The name of the user who was deleted is contained in acsTrapObjectTargetUserName. | 1.3.6.1.4.1.10418.26.0.9 | current |
| avctAcsLocalUserModifiedTrap NOTIFICATION-TYPE A user has been modified in the local user database. The name of the user who modified the data is contained in acsTrapObjectUserName. The name of the user who was modified is contained in acsTrapObjectTargetUserName. | 1.3.6.1.4.1.10418.26.0.10 | current |
| avctAcsFirmwareUpgradeStarted NOTIFICATION-TYPE The appliance has started an upgrade of a software image. The name of the user who initiate the process is contained in acsTrapObjectUserName. The current firmware version is contained in acsTrapFirmwareVersion. The new firmware version is contained in acsTrapNewFirmwareVersion. | 1.3.6.1.4.1.10418.26.0.11 | current |
| avctAcsFirmwareUpgradeResultsTrap NOTIFICATION-TYPE This trap is generated when Firmware upgraded is done to indicate the result. The new FW version is contained in acsTrapNewFirmwareVersion. The result of the process is contained in acsTrapFirmwareUpgradeResult. | 1.3.6.1.4.1.10418.26.0.12 | current |
| avctAcsApplianceAlertTrap NOTIFICATION-TYPE An appliance alert was detected on a ssh or telnet session. The name of user who was logged into the appliance when trap occurred is contained in acsTrapObjectUserName. The index of the appliance alert that was detected in the message is contained in acsTrapObjectAlertIndex. The appliance alert that was detected is contained in acsTrapObjectAlertString. The line text where the appliance alert was detected is contained in acsTrapObjectAlertMessage. | 1.3.6.1.4.1.10418.26.0.13 | current |
| avctAcsApplianceStartedTrap NOTIFICATION-TYPE This trap is generated when the appliance is started. | 1.3.6.1.4.1.10418.26.0.14 | current |
| avctAcsApplianceFIPStestFail NOTIFICATION-TYPE This trap is sent when FIPS self test failed. | 1.3.6.1.4.1.10418.26.0.16 | current |
| avctAcsFIPSmode NOTIFICATION-TYPE This trap is generated if FIPS module is enabled and service is in FIPS mode. The service name is contained in acsTrapObjectServiceName. | 1.3.6.1.4.1.10418.26.0.17 | current |
| avctAcsnoFIPSmode NOTIFICATION-TYPE This trap is generated if FIPS module is enabled and service is in non-FIPS mode. The service name is contained in acsTrapObjectServiceName. | 1.3.6.1.4.1.10418.26.0.18 | current |
| avctAcsconfigMd5Gen NOTIFICATION-TYPE This trap is generated when a NEW config Md5 is generated. The service name is contained in acsTrapObjectServiceName. | 1.3.6.1.4.1.10418.26.0.19 | current |
| avctAcsFailOver NOTIFICATION-TYPE This trap is generated when a Network Primary Failover event has occurred. The secondary is contained in acsTrapObjectNetworkSecondary. | 1.3.6.1.4.1.10418.26.0.20 | current |
| avctAcsFailOverRestore NOTIFICATION-TYPE This trap is generated when a Network Primary Failover has been restored. The primary is contained in acsTrapObjectNetworkPrimary. | 1.3.6.1.4.1.10418.26.0.21 | current |
| avctAcsSessionTimeoutTrap NOTIFICATION-TYPE This trap is generated when a session is terminated due to the session idle timeout. The name of the user who was terminated from the session is contained in acsTrapObjectTargetUserName. | 1.3.6.1.4.1.10418.26.0.22 | current |
| avctAcsIpsecCertificateExpired NOTIFICATION-TYPE This trap is generated when an IPsec Certificate expires or is nearing expiration. The certificate file name is contained in acsTrapObjectCertificateFileName. The expiration time is contained in acsTrapObjectCertExpirationTime. | 1.3.6.1.4.1.10418.26.0.24 | current |
| avctAcsIpsecConnectionEstablished NOTIFICATION-TYPE This trap is generated when an IPsec connection is established. The name of the connection is contained in acsTrapObjectConnectionName. | 1.3.6.1.4.1.10418.26.0.25 | current |
| avctAcsIpsecConnectionFailed NOTIFICATION-TYPE This trap is generated when an IPsec connection fails. The name of the connection is contained in acsTrapObjectConnectionName. The reason for failure is contained in acsTrapObjectConnectionReason. | 1.3.6.1.4.1.10418.26.0.26 | current |
| avctAcsIpsecConnectionTerminated NOTIFICATION-TYPE This trap is generated when an IPsec connection is terminated. The name of the connection is contained in acsTrapObjectConnectionName. | 1.3.6.1.4.1.10418.26.0.27 | current |
| avctAcsUserLoginTrap NOTIFICATION-TYPE This trap is sent when user logged into the appliance. The name of the user who logged in is contained in acsTrapObjectUserName and the method used to log into appliance is contained in acsTrapObjectSessionType. | 1.3.6.1.4.1.10418.26.0.50 | current |
| avctAcsUserLogoutTrap NOTIFICATION-TYPE A user logged out of the appliance. The name of the user who logged in is contained in acsTrapObjectUserName and the method used to log into appliance is contained in acsTrapObjectSessionType. | 1.3.6.1.4.1.10418.26.0.51 | current |
| avctAcsAuthenticationFailureTrap NOTIFICATION-TYPE A user failed to authenticate with the appliance. The name of the user who failed to authenticate is contained in acsTrapObjectUserName and the method used to log into appliance is contained in acsTrapObjectSessionType. | 1.3.6.1.4.1.10418.26.0.52 | current |
| avctAcsPortAuthenticationFailureTrap NOTIFICATION-TYPE This trap is sent when a serial session authentication fails. The name of the user who failed to authenticate is contained in acsTrapObjectUserName. The serial port number on the appliance is contained in acsTrapObjectSerialPortNumber. The serial port name on the appliance is contained in acsTrapObjectSerialPortName The type of protocol configured on this port is contained in acsTrapObjectSerialSessionType. | 1.3.6.1.4.1.10418.26.0.53 | current |
| avctAcsPortPowerOnDetectTrap NOTIFICATION-TYPE The appliance has detected that the power on/off control signal (RS232C - DCD signal) is high on a serial port indicating that the server attached to the port is powered on. This trap is sent on initialization if the condition is detected. Subsequent traps occur only if there is a transition of the DCD signal from low to high. The affected serial port number is contained in acsTrapObjectSerialPortNumber. The affected serial port name is contained in acsTrapObjectSerialPortName. | 1.3.6.1.4.1.10418.26.0.100 | current |
| avctAcsPortPowerOffDetectTrap NOTIFICATION-TYPE The appliance has detected that the power on/off control signal (RS232C - DCD signal) is low on a serial port indicating that the server attached to the port is powered off. This trap is sent on initialization if the condition is detected. Subsequent traps occur only if there is a transition of the DCD signal from high to low. The affected serial port number is contained in acsTrapObjectSerialPortNumber. The affected serial port name is contained in acsTrapObjectSerialPortName. | 1.3.6.1.4.1.10418.26.0.101 | current |
| avctAcsPortAutoDiscoverSuccess NOTIFICATION-TYPE The appliance has used auto discovery to discover a name for the target device attached to the serial port. The affected serial port number is contained in acsTrapObjectSerialPortNumber. The new and old serial port names are contained in acsTrapObjectSerialPortName. | 1.3.6.1.4.1.10418.26.0.102 | current |
| avctAcsPortAutoDiscoverFailure NOTIFICATION-TYPE The appliance auto discovery of the name of the target device attached to the serial port has failed. The affected serial port number is contained in acsTrapObjectSerialPortNumber. The old serial port name remains and is contained in acsTrapObjectSerialPortName. | 1.3.6.1.4.1.10418.26.0.103 | current |
| avctAcsModemRegistrationTrap NOTIFICATION-TYPE This trap is sent when the modem has registered with the network. The device name of the modem is contained in acsTrapObjectModemDeviceName. The network connection type (home network vs roaming) is contained in acsTrapObjectModemNetworkConnection. | 1.3.6.1.4.1.10418.26.0.120 | current |
| avctAcsModemRegistrationFailedTrap NOTIFICATION-TYPE This trap is sent when the modem registration has failed. The device name of the modem is contained in acsTrapObjectModemDeviceName The failure reason is contained in acsTrapObjectModemRegistrationFailReason. | 1.3.6.1.4.1.10418.26.0.121 | current |
| avctAcsModemConnectionEstablishedTrap NOTIFICATION-TYPE This trap is sent when a modem connection has been established. The device name of the modem is contained in acsTrapObjectModemDeviceName. | 1.3.6.1.4.1.10418.26.0.122 | current |
| avctAcsModemConnectionTerminatedTrap NOTIFICATION-TYPE This trap is sent when a modem connection has been terminated. The device name of the modem is contained in acsTrapObjectModemDeviceName. | 1.3.6.1.4.1.10418.26.0.123 | current |
| avctAcsModemConnectionFailedTrap NOTIFICATION-TYPE This trap is sent when a modem connection has failed. The device name of the modem is contained in acsTrapObjectModemDeviceName. | 1.3.6.1.4.1.10418.26.0.124 | current |
| avctAcsModemStatusTrap NOTIFICATION-TYPE This trap is sent when a modem is enabled or disabled. The device name of the modem is contained in acsTrapObjectModemDeviceName. The new status of the modem is contained in acsTrapObjectModemStatus. | 1.3.6.1.4.1.10418.26.0.125 | current |
| avctAcsScheduledTaskStart NOTIFICATION-TYPE This trap is sent when a scheduled task completes. The name of the task is contained in acsTrapObjectTaskName. | 1.3.6.1.4.1.10418.26.0.140 | current |
| avctAcsScheduledTaskComplete NOTIFICATION-TYPE This trap is sent when a scheduled task completes. The name of the task is contained in acsTrapObjectTaskName. The result of the task is contained in acsTrapObjectTaskResult. | 1.3.6.1.4.1.10418.26.0.141 | current |
| avctAcsScheduledTaskFailed NOTIFICATION-TYPE This trap is sent when a scheduled task fails. The name of the task is contained in acsTrapObjectTaskName. The result of the task is contained in acsTrapObjectTaskResult. | 1.3.6.1.4.1.10418.26.0.142 | current |
| avctAcsSerialSessionStartedTrap NOTIFICATION-TYPE This trap is sent when a serial session has started on particular port. The name of the user who is connected to the session is contained in acsTrapObjectUserName. The serial port number on the appliance is contained in acsTrapObjectSerialPortNumber. The serial port name on the appliance is contained in acsTrapObjectSerialPortName The type of protocol running on this serial port is contained in acsTrapObjectSerialSessionType. The numbe of sessions openned in this port is contained in acsTrapObjecSerialSessionNumbers. | 1.3.6.1.4.1.10418.26.0.150 | current |
| avctAcsSerialSessionStoppedTrap NOTIFICATION-TYPE This trap is sent when a serial session has stopped. The user who was connected to the session is contained in acsTrapObjectUserName. The serial port number on the appliance is contained in acsTrapObjectSerialPortNumber. The serial port name on the appliance is contained in acsTrapObjectSerialPortName The type of protocol running on this port is contained in acsTrapObjectSerialSessionType. The number of serial sessions openned in this port is contained in acsTrapObjectSessionNumbers. | 1.3.6.1.4.1.10418.26.0.151 | current |
| avctAcsPortAlertTrap NOTIFICATION-TYPE The appliance detected a port alert on a serial port. The serial port number where the port alert was detected on is contained in acsTrapObjectSerialPortNumber. The serial port name where the port alert was detected on is contained in acsTrapObjectSerialPortName. The index of the port alert that was detected is contained in acsTrapObjectAlertIndex. The port alert that was detected is contained in acsTrapObjectAlertString. The line text where the port alert was detected is contained in acsTrapObjectAlertMessage. | 1.3.6.1.4.1.10418.26.0.152 | current |
| avctAcsDataBufferNFSFailure NOTIFICATION-TYPE This trap is generated when the appliance is sending data buffering data to a NFS server and the write operation fails. | 1.3.6.1.4.1.10418.26.0.153 | current |
| avctAcsDataBufferNFSRecovery NOTIFICATION-TYPE This trap is generated when the NFS server is back online after a failure in a Data Buffering write operation. | 1.3.6.1.4.1.10418.26.0.154 | current |
| avctAcsDataBufferFullThresholdLowTrap NOTIFICATION-TYPE This trap is generated when the appliance is managed by DSView and global data buffer has reached configured Low level Threshold. acsTrapObjectDataBufferSize is current size of the buffer. | 1.3.6.1.4.1.10418.26.0.200 | current |
| avctAcsDataBufferFullThresholdMedTrap NOTIFICATION-TYPE This trap is generated when the appliance is managed by DSView and global data buffer has reached configured Med level Threshold. acsTrapObjectDataBufferSize is current size of the buffer. | 1.3.6.1.4.1.10418.26.0.201 | current |
| avctAcsDataBufferFullLostDataTrap NOTIFICATION-TYPE This trap is generated when the appliance is managed by DSView and global data buffer has exceeded beyond the size of buffer and data lost has occurred. | 1.3.6.1.4.1.10418.26.0.202 | current |
| avctAcsPduOnlineTrap NOTIFICATION-TYPE A power device unit(PDU) attached to the appliance is online. The port number on the appliance that the power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The power device ID is contained in acsTrapObjectPduId. The number of outlets of the power device is contained in acsTrapObjectPduSocket. The vendor of the power device is contained in acsTrapObjectPduVendor | 1.3.6.1.4.1.10418.26.0.300 | current |
| avctAcsPduOfflineTrap NOTIFICATION-TYPE A power device attached to the appliance is offline. The port number on the appliance that the power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The power device ID is contained in acsTrapObjectPduId. The number of outlets of the power device is contained in acsTrapObjectPduSocket. The vendor of the power device is contained in acsTrapObjectPduVendor. | 1.3.6.1.4.1.10418.26.0.301 | current |
| avctAcsPduIdChangedTrap NOTIFICATION-TYPE The ID of the PDU was changed. The port number on the appliance that the power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The old power device ID is contained in acsTrapObjectPduIdOld. The new power device ID is contained in acsTrapObjectPduId. The vendor of the power device is contained in acsTrapObjectPduVendor. | 1.3.6.1.4.1.10418.26.0.302 | current |
| avctAcsPduMaxLoadHighTrap NOTIFICATION-TYPE The current on a power device attached to the appliance is above its high critical threshold. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the problem is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the problem is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the problem is contained in the acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.303 | current |
| avctAcsPduMinLoadLowTrap NOTIFICATION-TYPE The current on a power device attached to the appliance is below its low critical threshold. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the problem is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the problem is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the problem is contained in the acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.304 | current |
| avctAcsPduFirmwareUpgradeStarted NOTIFICATION-TYPE The appliance has started an upgrade of the PM software. The name of the user who initiate the process is contained in acsTrapObjectUserName. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The current firmware version is contained in acsTrapFirmwareVersion. The new firmware version is contained in acsTrapNewFirmwareVersion. | 1.3.6.1.4.1.10418.26.0.307 | current |
| avctAcsPduFirmwareUpgradeResultsTrap NOTIFICATION-TYPE This trap is generated when Firmware upgraded is done to indicate the result. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that gone beneath the minimum threshold is contained in the acsTrapObjectPduNumber. The new FW version is contained in acsTrapNewFirmwareVersion. The result of the process is contained in acsTrapFirmwareUpgradeResult. | 1.3.6.1.4.1.10418.26.0.308 | current |
| avctAcsPduHwOcpTripped NOTIFICATION-TYPE This trap is generated when the HW overcurrent protection mechanism is tripped. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The number of the PDU that was tripped is contained in the acsTrapObjectPduNumber. The ID of the PDU that was tripped is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the event is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the event is contained in the acsTrapObjectPduElementName. | 1.3.6.1.4.1.10418.26.0.309 | current |
| avctAcsPduHwOcpReset NOTIFICATION-TYPE This trap is generated when the HW overcurrent protection mechanism is reset. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The number of the PDU whose HW OCP was reset is contained in the acsTrapObjectPduNumber. The ID of the PDU ID whose HW OCP was reset is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the event is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the event is contained in the acsTrapObjectPduElementName. | 1.3.6.1.4.1.10418.26.0.310 | current |
| avctAcsPduMaxLoadBackTrap NOTIFICATION-TYPE The current on a power device attached to the appliance is back to normal. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the event is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the event is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the event is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the event is contained in the acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.311 | current |
| avctAcsPduWarnLoadTrap NOTIFICATION-TYPE The current on a power device attached to the appliance is above its high warning threshold. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the problem is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the problem is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the problem is contained in the acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.312 | current |
| avctAcsPduLowLoadLowTrap NOTIFICATION-TYPE The current on a power device attached to the appliance is below its low warning threshold. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the problem is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the problem is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the problem is contained in the acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.313 | current |
| avctAcsPduBlownFuseTrap NOTIFICATION-TYPE Blown fuse detection in one circuit of the PDU. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the problem is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the problem is contained in the acsTrapObjectPduId. The Type of the PDU Element that detected the problem is contained in the acsTrapObjectPduElementType. The Name of the Pdu Element that detected the problem is contained in the acsTrapObjectPduElementName. The status detected when this trap was originated is contained in acsTrapObjectPduFuseStatus. | 1.3.6.1.4.1.10418.26.0.314 | current |
| avctAcsPduInletAlarmTrap NOTIFICATION-TYPE The appliance detected an alarm on a power device inlet. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the event is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the event is contained in the acsTrapObjectPduId. The Name of the PDU Element that is experiencing the problem is contained in the acsTrapObjectPduElementName. | 1.3.6.1.4.1.10418.26.0.315 | current |
| avctAcsPduInletRestoredTrap NOTIFICATION-TYPE The appliance detected that a power device inlet has been restored to normal operation. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the event is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the event is contained in the acsTrapObjectPduId. The Name of the PDU Element to which normal operation has been restored is contained in the acsTrapObjectPduElementName. | 1.3.6.1.4.1.10418.26.0.316 | current |
| avctAcsRtsSourceTransferTrap NOTIFICATION-TYPE The appliance detected that the active power source has changed on the Rack Transfer switch. The port number on the appliance that the power device is attached to is contained in the acsTrapObjectSerialPortNumber. The PDU# that detected the event is contained in the acsTrapObjectPduNumber. The ID of the PDU that detected the event is contained in the acsTrapObjectPduId. The Name of the power source (inlet) which was previously active is contained in the acsTrapObjectPduElementName. The Name of the power source (inlet) which is currently active is contained in the acsTrapObjectPduNewElementName. | 1.3.6.1.4.1.10418.26.0.317 | current |
| avctAcsOutletNameChangedTrap NOTIFICATION-TYPE The name of socket was changed. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The number of the power device is contained in the acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that has changed the name is contained in acsTrapObjectSocketNumber. The old socket name is contained in acsTrapObjectSocketOldName. The socket name that has changed to the on state is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.350 | current |
| avctAcsOutletCmdOnTrap NOTIFICATION-TYPE An outlet on a chain of power device has been issued the on command. The name of the user who issued the on command is contained in acsTrapObjectUserName. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that was issued the on command is contained in acsTrapObjectSocketNumber. The socket name that was issued the on command is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.351 | current |
| avctAcsOutletStatusOnTrap NOTIFICATION-TYPE An outlet on a chain of power device has changed to the on state. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that has changed to the on state is contained acsTrapObjectSocketNumber. The number of the power device is contained in the acsTrapObjectPduNumber. The socket name that has changed to the on state is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.352 | current |
| avctAcsOutletCmdOffTrap NOTIFICATION-TYPE An outlet on a chain of power device has been issued the off command. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that was issued the off command is contained in acsTrapObjectSocketNumber. The socket name that was issued the off command is contained in acsTrapObjectSocketName. The name of the user who issued the off command is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.353 | current |
| avctAcsOutletStatusOffTrap NOTIFICATION-TYPE An outlet on a chain of power device has changed to the off state. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The number of the power device is contained in the acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that has changed to the off state is contained in acsTrapObjectSocketNumber. The socket name that has changed to the off state is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.354 | current |
| avctAcsOutletCmdCycleTrap NOTIFICATION-TYPE An outlet on a chain of power device has been issued the cycle command. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that was issued the cycle command is contained in acsTrapObjectSocketNumber. The socket name that was issued the cycle command is contained in acsTrapObjectSocketName. The name of the user who issued the cycle command is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.355 | current |
| avctAcsOutletCycleFinishedTrap NOTIFICATION-TYPE An outlet on a chain of power device has completed the cycle command. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The power device number in the chain is contained in acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that was issued the cycle command is contained in acsTrapObjectSocketNumber. The socket name that was issued the cycle command is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.356 | current |
| avctAcsOutletOnSenseFailTrap NOTIFICATION-TYPE A power device attached to the appliance has detected an on sense failure for a socket. An on sense failure occurs when a socket should be in the on state but is actually in the off state. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The number of the power device is contained in the acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that has changed to the on state is contained in acsTrapObjectSocketNumber. The socket name that has changed to the on state is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.357 | current |
| avctAcsOutletOffSenseFailTrap NOTIFICATION-TYPE A power device attached to the appliance has detected an off sense failure for a socket. An off sense failure occurs when a socket should be in the off state but is actually in the on state. The port number on the appliance that the chain of power device is attached to is contained in acsTrapObjectSerialPortNumber. The number of the power device is contained in the acsTrapObjectPduNumber. The ID of the power device is contained in acsTrapObjectPduId. The socket number that has changed to the on state is contained in acsTrapObjectSocketNumber. The socket name that has changed to the on state is contained in acsTrapObjectSocketName. | 1.3.6.1.4.1.10418.26.0.358 | current |
| avctAcsUpsOnlineTrap NOTIFICATION-TYPE An uninterruptible power system unit (UPS) attached to the appliance is online. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The UPS device ID is contained in acsTrapObjectUpsId. The vendor of the UPS device is contained in acsTrapObjectUpsVendor | 1.3.6.1.4.1.10418.26.0.370 | current |
| avctAcsUpsOfflineTrap NOTIFICATION-TYPE A UPS attached to the appliance is offline. The port number on the appliance that the power device is attached to is contained in acsTrapObjectSerialPortNumber. The UPS device ID is contained in acsTrapObjectUpsId. The vendor of the power device is contained in acsTrapObjectUpsVendor. | 1.3.6.1.4.1.10418.26.0.371 | current |
| avctAcsUpsIdChangedTrap NOTIFICATION-TYPE The ID of the UPS was changed. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The old UPS device ID is contained in acsTrapObjectUpsIdOld. The new UPS device ID is contained in acsTrapObjectUpsId. The vendor of the UPS device is contained in acsTrapObjectUpsVendor. | 1.3.6.1.4.1.10418.26.0.372 | current |
| avctAcsUpsOutputOffTrap NOTIFICATION-TYPE The system output of the UPS has changed to the off state. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.373 | current |
| avctAcsUpsBatteryDischargingTrap NOTIFICATION-TYPE The UPS battery charge state has changed to discharging. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The estimated number of minutes of battery time is contained in acsTrapObjectUpsBatteryTimeRemaining. | 1.3.6.1.4.1.10418.26.0.374 | current |
| avctAcsUpsBatteryLowTrap NOTIFICATION-TYPE The calculated battery time on the UPS battery has reached the low battery threshold. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The estimated of minutes of battery time remaining is contained in acsTrapObjectUpsBatteryTimeRemaining. | 1.3.6.1.4.1.10418.26.0.375 | current |
| avctAcsUpsSystemInputPowerProblemTrap NOTIFICATION-TYPE The UPS power input is not qualified to provide power to the system. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.376 | current |
| avctAcsUpsReplaceBatteryTrap NOTIFICATION-TYPE The UPS battery is due for replacement. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.377 | current |
| avctAcsUpsBatteryTestFailedTrap NOTIFICATION-TYPE The UPS battery test has failed. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.378 | current |
| avctAcsUpsShutdownPendingTrap NOTIFICATION-TYPE UPS Shutdown is pending. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.379 | current |
| avctAcsUpsBatteryUndervoltageTrap NOTIFICATION-TYPE UPS battery voltage is too low. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.380 | current |
| avctAcsUpsBatteryOvervoltageTrap NOTIFICATION-TYPE UPS battery voltage has exceeded the limit. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.381 | current |
| avctAcsUpsSystemInputPowerRestoredTrap NOTIFICATION-TYPE UPS system input power has been restored. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.382 | current |
| avctAcsUpsOutputProblemTrap NOTIFICATION-TYPE There is a problem with the UPS output: there is an Output Overvoltage, Undervoltage or Overload condition. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.383 | current |
| avctAcsUpsHardwareFailureTrap NOTIFICATION-TYPE There is a hardware failure on the UPS. Possible failures include system fan failure, charger failure, inverter failure, rectifier failure, parallel comm warning, loss of redundancy, emergency power off - latched, input wiring fault, DC to DC converter fault. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.384 | current |
| avctAcsUpsOutputOnBypassTrap NOTIFICATION-TYPE The output power of the UPS is being supplied by the bypass. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.385 | current |
| avctAcsUpsOutputNormalTrap NOTIFICATION-TYPE The system output of the UPS has returned to the normal state. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. | 1.3.6.1.4.1.10418.26.0.386 | current |
| avctAcsUpsOutletGroupCmdOnTrap NOTIFICATION-TYPE An outlet group on a UPS device has been issued the on command. The name of the user who issued the on command is contained in acsTrapObjectUserName. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that was issued the on command is contained in acsTrapObjectUpsOutletGroupNumber. The outlet group name that was issued the on command is contained in acsTrapObjectUpsOutletGroupName. | 1.3.6.1.4.1.10418.26.0.387 | current |
| avctAcsUpsOutletGroupStatusOnTrap NOTIFICATION-TYPE An outlet group on a UPS device has changed to the on state. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that has changed to the on state is contained acsTrapObjectUpsOutletGroupNumber. The outlet group name that has changed to the on state is contained in acsTrapObjectUpsOutletGroupName. | 1.3.6.1.4.1.10418.26.0.388 | current |
| avctAcsUpsOutletGroupCmdOffTrap NOTIFICATION-TYPE An outlet group on a UPS device has been issued the off command. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that was issued the off command is contained in acsTrapObjectUpsOutletGroupNumber. The outlet group name that was issued the off command is contained in acsTrapObjectUpsOutletGroupName. The name of the user who issued the off command is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.389 | current |
| avctAcsUpsOutletGroupStatusOffTrap NOTIFICATION-TYPE An outlet group on a UPS device has changed to the off state. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that has changed to the off state is contained in acsTrapObjectUpsOutletGroupNumber. The outlet group name that has changed to the off state is contained in acsTrapObjectUpsOutletGroupName. | 1.3.6.1.4.1.10418.26.0.390 | current |
| avctAcsUpsOutletGroupCmdCycleTrap NOTIFICATION-TYPE An outlet group on a UPS device has been issued the cycle command. The port number on the appliance that the UPS is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that was issued the cycle command is contained in acsTrapObjectUpsOutletGroupNumber. The outlet group name that was issued the cycle command is contained in acsTrapObjectUpsOutletGroupName. The name of the user who issued the cycle command is contained in acsTrapObjectUserName. | 1.3.6.1.4.1.10418.26.0.391 | current |
| avctAcsUpsOutletGroupCycleFinishedTrap NOTIFICATION-TYPE An outlet group on a UPS device has completed the cycle command. The port number on the appliance that the UPS device is attached to is contained in acsTrapObjectSerialPortNumber. The ID of the UPS device is contained in acsTrapObjectUpsId. The outlet group number that was issued the cycle command is contained in acsTrapObjectUpsOutletGroupNumber. The outlet group name that was issued the cycle command is contained in acsTrapObjectUpsOutletGroupName. | 1.3.6.1.4.1.10418.26.0.392 | current |
| avctAcsApplianceSensorThresholdNormalTrap NOTIFICATION-TYPE A sensor attached to the appliance cleared its alarm. The sensor type is contained in acsTrapObjectApplianceSensorType. The sensor name is contained in acsTrapObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.400 | current |
| avctAcsApplianceSensorThresholdHighCriticalTrap NOTIFICATION-TYPE A sensor attached to the appliance has breached its high critical threshold. The sensor type is contained in acsTrapObjectApplianceSensorType. The sensor name is contained in acsTrapObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.401 | current |
| avctAcsApplianceSensorThresholdHighWarningTrap NOTIFICATION-TYPE A sensor attached to the appliance has breached its high warning threshold. The sensor type is contained in acsTrapObjectApplianceSensorType. The sensor name is contained in acsTrapObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.402 | current |
| avctAcsApplianceSensorThresholdLowWarningTrap NOTIFICATION-TYPE A sensor attached to the appliance has breached is low warning threshold. The sensor type is contained in acsTrap_ObjectApplianceSensorType. The sensor name is contained in acsTrap_ObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.403 | current |
| avctAcsApplianceSensorThresholdLowCriticalTrap NOTIFICATION-TYPE A sensor attached to the appliance has breached the low critical threshold. The sensor type is contained in acsTrapObjectApplianceSensorType. The sensor name is contained in acsTrapObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.404 | current |
| avctAcsApplianceSensorDigitalAlarmTrap NOTIFICATION-TYPE A sensor attached to the appliance is in its alarm state. The sensor type is contained in acsTrapObjectApplianceSensorType. The sensor name is contained in acsTrapObjectApplianceSensorName. The present sensor value is contained in acsTrapObjectApplianceSensorValue. | 1.3.6.1.4.1.10418.26.0.405 | current |
| avctAcsDialInCallAnswered NOTIFICATION-TYPE The appliance has answered a dial-in call. The incoming caller ID phone number is contained in acsTrapObjectCallerIdNumber. The incoming caller ID name is contained in acsTrapObjectCallerIdName. | 1.3.6.1.4.1.10418.26.0.450 | current |
| avctAcsDialInCallBlocked NOTIFICATION-TYPE The appliance has blocked a dial-in call. The incoming caller ID phone number is contained in acsTrapObjectCallerIdNumber. The incoming caller ID name is contained in acsTrapObjectCallerIdName. | 1.3.6.1.4.1.10418.26.0.451 | current |
| avctAcsDialInLineVoltageDroppedTrap NOTIFICATION-TYPE This trap is generated when the dial-in modem line voltage has dropped. | 1.3.6.1.4.1.10418.26.0.452 | current |
| avctAcsDialInLineVoltageRestoredTrap NOTIFICATION-TYPE This trap is generated when the dial-in modem line voltage has been restored. | 1.3.6.1.4.1.10418.26.0.453 | current |
| avctAcsTemperatureExceededMaxTrap NOTIFICATION-TYPE The appliance temperature has exceeded the maximum threshold configured. The maximum temperature configured is contained in acsTrapObjectTemperatureMaximumValue. The threshold configured is contained in the acsTrapObjectTemperatureMaxThreshold. The current temperature is contained in acsTrapObjectTemperatureCurrent. | 1.3.6.1.4.1.10418.26.0.500 | current |
| avctAcsTemperatureReachedMaxTrap NOTIFICATION-TYPE The appliance temperature has gone beneath the maximum threshold configured. The maximum temperature configured is contained in acsTrapObjectTemperatureMaximumValue The threshold confiugred is contained in acsTrapObjectTemperatureMaxThreshold. The current temperature is contained in acsTrapObjectTemperatureCurrent. | 1.3.6.1.4.1.10418.26.0.501 | current |
| avctAcsTemperatureExceededMinTrap NOTIFICATION-TYPE The appliance temperature has exceeded the minimum threshold configured. The minimum temperature configured is contained in acsTrapObjectTemperatureMinimumValue. The threshold configured is contained in the acsTrapObjectTemperatureMinThreshold. The current temperature is contained in acsTrapObjectTemperatureCurrent. | 1.3.6.1.4.1.10418.26.0.502 | current |
| avctAcsTemperatureReachedMinTrap NOTIFICATION-TYPE The appliance temperature has gone beneath the minimum threshold configured. The minimum temperature configured is contained in acsTrapObjectTemperatureMinimumValue The threshold confiugred is contained in acsTrapObjectTemperatureMinThreshold. The current temperature is contained in acsTrapObjectTemperatureCurrent. | 1.3.6.1.4.1.10418.26.0.503 | current |
| avctAcsPowerSupplyTrap NOTIFICATION-TYPE The state of the appliance power supply has changed. The number of power supply is contained in acsTrapObjectPowerSupplyNumber. The old state of the power supply is contained in acsTrapObjectSupplyOldState. The new state of the power supply is contained in acsTrapObjectSupplyNewState. | 1.3.6.1.4.1.10418.26.0.504 | current |
| avctAcsPlugDeviceInsertTrap NOTIFICATION-TYPE A plugged device has been inserted in the appliance. The device name used by plugged device is contained in acsTrapObjectPlugDeviceName. The type of the plugged device is contained in acsTrapObjectPlugDeviceType. The info about the plugged device is contained in acsTrapObjectPlugDeviceInfo. | 1.3.6.1.4.1.10418.26.0.505 | current |
| avctAcsPlugDeviceEjectTrap NOTIFICATION-TYPE A plugged device has been ejected from the appliance. The device name used by plugged device is contained in acsTrapObjectPlugDeviceName. The type of the plugged device is contained in acsTrapObjectPlugDeviceType. The info about the plugged device is contained in acsTrapObjectPlugDeviceInfo. | 1.3.6.1.4.1.10418.26.0.506 | current |
| avctAcsSensorThresholdNormalTrap NOTIFICATION-TYPE A sensor attached to the appliance cleared its alarm. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.507 | current |
| avctAcsSensorThresholdHighCriticalTrap NOTIFICATION-TYPE A sensor attached to the appliance is above its high critical threshold. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.508 | current |
| avctAcsSensorThresholdHighWarningTrap NOTIFICATION-TYPE A sensor attached to the appliance is above its high warning threshold. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.509 | current |
| avctAcsSensorThresholdLowWarningTrap NOTIFICATION-TYPE A sensor attached to the appliance is below its low warning threshold. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.510 | current |
| avctAcsSensorThresholdLowCriticalTrap NOTIFICATION-TYPE A sensor attached to the appliance is below its low critical threshold. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.511 | current |
| avctAcsSensorThresholdDigitalSensorAlarmTrap NOTIFICATION-TYPE A digital sensor attached to the appliance is in its alarm state. The port number of the appliance where the sensor is attached to is contained in acsTrapObjectSerialPortNumber. The number of the PDU where the sensor is attached is contained in acsTrapObjectPduNumber. The ID of the PDU where the sensor is attached is contained in acsTrapObjectPduId. The Type of the sensor is contained in acsTrapObjectPduElementType. The Name of the sensor is contained in acsTrapObjectPduElementName. The current value detected when this trap was originated is contained in acsTrapObjectPduCurrentValue. | 1.3.6.1.4.1.10418.26.0.512 | current |
| avctAcsCpuTemperatureExceededMaxTrap NOTIFICATION-TYPE The CPU temperature has exceeded the maximum threshold configured. The maximum temperature configured is contained in acsTrapObjectTemperatureMaximumCpuValue. The threshold configured is contained in the acsTrapObjectTemperatureMaxCpuThreshold. The current CPU temperature is contained in acsTrapObjectTemperatureCpuCurrent. | 1.3.6.1.4.1.10418.26.0.513 | current |
| avctAcsCpuTemperatureReachedMaxTrap NOTIFICATION-TYPE The CPU temperature has gone beneath the maximum threshold configured. The maximum temperature configured is contained in acsTrapObjectTemperatureMaximumCpuValue The threshold confiugred is contained in acsTrapObjectTemperatureMaxCpuThreshold. The CPU temperature is contained in acsTrapObjectTemperatureCpuCurrent. | 1.3.6.1.4.1.10418.26.0.514 | current |
| avctAcsCpuTemperatureExceededMinTrap NOTIFICATION-TYPE The CPU temperature has exceeded the minimum threshold configured. The minimum temperature configured is contained in acsTrapObjectTemperatureMinimumCpuValue. The threshold configured is contained in the acsTrapObjectTemperatureMinCpuThreshold. The cpu temperature is contained in acsTrapObjectTemperatureCpuCurrent. | 1.3.6.1.4.1.10418.26.0.515 | current |
| avctAcsCpuTemperatureReachedMinTrap NOTIFICATION-TYPE The CPU temperature has gone beneath the minimum threshold configured. The minimum temperature configured is contained in acsTrapObjectTemperatureMinimumCpuValue The threshold confiugred is contained in acsTrapObjectTemperatureMinCpuThreshold. The cpu temperature is contained in acsTrapObjectTemperatureCpuCurrent. | 1.3.6.1.4.1.10418.26.0.516 | current |
| avctAcsTestTrap NOTIFICATION-TYPE Used to test SNMP Trap functionality. | 1.3.6.1.4.1.10418.26.0.517 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| acsTrapObjectsGroup OBJECT-GROUP A collection of trap data objects. | 1.3.6.1.4.1.10418.26.15.1.1 | current |
| acsTrapsGroup NOTIFICATION-GROUP A collection of traps. | 1.3.6.1.4.1.10418.26.15.1.2 | current |