MIBs Depot

XF-RADIOLINK-PTP-RADIO-MIB

Registered at
1.3.6.1.4.1.193.81.3.4.3
Last updated
2020-09-22 00:00
Organization
Ericsson AB
Revisions
2020-09-22 00:00, 2019-11-26 00:00, 2019-10-14 00:00, 2019-06-04 00:00, 2019-05-16 00:00, 2019-04-30 00:00, 2019-01-17 00:00, 2018-10-29 00:00, 2018-09-03 00:00, 2018-04-06 00:00, 2018-01-30 00:00, 2017-11-23 00:00, 2017-09-19 00:00, 2017-09-05 00:00, 2017-07-25 00:00, 2017-06-28 00:00, 2017-05-24 00:00, 2016-12-20 00:00, 2016-06-16 00:00, 2016-06-01 00:00, 2016-05-16 00:00, 2016-05-10 00:00, 2016-04-12 00:00, 2016-02-22 00:00, 2016-02-06 00:00, 2016-02-05 00:00, 2015-12-11 00:00, 2015-11-05 00:00, 2015-08-31 00:00, 2015-07-02 00:00, 2015-06-25 00:00, 2015-06-08 00:00, 2015-04-23 00:00, 2015-04-20 00:00, 2015-04-02 00:00, 2015-02-26 00:00, 2015-01-23 10:00, 2015-01-23 00:00, 2015-01-09 00:00, 2014-02-20 00:00, 2013-11-22 00:00, 2013-11-19 14:00, 2011-05-23 00:00, 2011-02-09 00:00, 2011-02-01 00:00, 2010-12-10 00:00, 2010-10-20 00:00, 2010-09-23 00:00, 2010-06-15 00:00, 2010-06-04 00:00, 2010-01-19 00:00, 2009-12-01 00:00, 2009-11-18 00:00, 2009-06-26 00:00, 2009-06-24 00:00, 2009-04-20 00:00, 2009-04-14 00:00, 2008-10-02 00:00, 2008-09-16 00:00, 2008-06-25 00:00, 2008-06-24 00:00, 2008-06-18 00:00, 2008-06-17 00:00, 2008-06-04 00:00, 2007-06-04 00:00, 2006-09-19 13:20, 2006-08-29 00:00, 2006-03-20 00:00, 2006-02-24 00:00, 2006-01-31 00:00, 2004-12-13 00:00, 2004-07-02 00:00, 2004-06-16 00:00, 2004-05-25 00:00, 2004-04-26 00:00, 2004-01-20 00:00, 2003-12-17 10:00
Namespace
ericsson
Source file
XF-RADIOLINK-PTP-RADIO-MIB
Digest
sha256:4119f7a8d0030065209ac1d5cfd66797de1038c8bff3b2b1a8f85a1d2ade276f

Description

This MIB defines objects for point-to-point Radio Link RAUs.

Contact

Ericsson AB Transmission & Transport Networks SE-431 84 Molndal Sweden

Imports

FromSymbols
ENTITY-MIBentPhysicalIndex
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
XF-RADIOLINK-PTP-TERMINAL-MIBxfTermRowIndex
XF-TOP-MIBxfRadioLink

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
HC-PerfHist-TC-MIB
IANA-ENTITY-MIB
IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB
XF-RADIOLINK-PTP-RADIO-MIB
XF-RADIOLINK-PTP-TERMINAL-MIB
XF-TOP-MIB

Textual conventions

NameOIDSyntaxAccessStatus
ATPCFallbackEnable
TEXTUAL-CONVENTION
ATPC fallback enable status.
current
BoosterCapability
TEXTUAL-CONVENTION
Booster capabilities values codes.
current
RAUAtpcCapability
TEXTUAL-CONVENTION
This TC enumerates the ATPC capability.
current
RAUChannelSpacingCapability
TEXTUAL-CONVENTION
Channel spacing capability.
current
RAUModCapability
TEXTUAL-CONVENTION
This TC enumerates the modulation capabilities. Modulation capabilities is indicated by 5 bits: bits 01234 00000 undetermined 00001 C-QPSK 00010 16-QAM 00011 C-QPSK & 16-QAM 00100 128-QAM 01000 32-QAM 10000 64-QAM ... 11111 C-QPSK & 16-QAM & 128-QAM & 32-QAM & 64-QAM
current
RAUModulation
TEXTUAL-CONVENTION
Type of modulation.
current
RAURfLoopAvailable
TEXTUAL-CONVENTION
This TC enumerates the RF loop.
current
RFTxOperStatus
TEXTUAL-CONVENTION
This TC enumerates the Tx operational status.
current
RauSec
TEXTUAL-CONVENTION
Spectrum Effeciency Class.
current
RfInputPower
TEXTUAL-CONVENTION
RF Input power in dBm/10.
current
RfOutputPower
TEXTUAL-CONVENTION
RF output power in dBm.
current

Objects

NameOIDSyntaxAccessStatus
xfRadioLinkPtpRadioObjects
OBJECT-IDENTITY
1.3.6.1.4.1.193.81.3.4.3.1
xfRAUTable
OBJECT-TYPE
Table for Radiolink point-to-point radios managed objects. Table indexed with entPhysicalIndex.
1.3.6.1.4.1.193.81.3.4.3.1.1not-accessiblecurrent
xfRAUEntry
OBJECT-TYPE
An entry in xfRadioTable.
1.3.6.1.4.1.193.81.3.4.3.1.1.1not-accessiblecurrent
xfRAUAlarmStatus
OBJECT-TYPE
This object shows the alarm status of the radio unit. atpcCability - The terminal is configured for ATPC, but the radio does not support ATPC. This alarm is activated only if ATPC is turned on (any direction). sdcHwErrorMain - Received RF input signal level for Main path (of SDC TRX) has dropped below the threshold for the receiver. sdcHwErrorDiv - Received RF input signal level for Diversity path (of SDC TRX) has dropped below the threshold for the receiver. sdcDadeCalMismatch - A TRX is connected and its Serial Number doesn't match with the serial number stored into MO xfTRXSdcSerialNumber. insufficientResourceRauXpic - Connected RAU is missing capabilities for XPIC. companionRauMismatch - Connected RAU does not match with the companion one, either in 1+1 RLP or XPIC.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.1Bits {atpcCapability0(0), atpcCapability1(1), atpcCapability2(2), configurationInvalid0(3), configurationInvalid1(4), configurationInvalid2(5), sdcHwErrorMain0(6), sdcHwErrorMain1(7), sdcHwErrorMain2(8), sdcHwErrorDiv0(9), sdcHwErrorDiv1(10), sdcHwErrorDiv2(11), sdcDadeCalMismatch0(12), sdcDadeCalMismatch1(13), sdcDadeCalMismatch2(14), insufficientResourceRauXpic0(15), insufficientResourceRauXpic1(16), insufficientResourceRauXpic2(17), companionRauMismatch0(18), companionRauMismatch1(19), companionRauMismatch2(20)}read-onlycurrent
xfRAURfLoopAvailable
OBJECT-TYPE
This object inidicates if RF loop is available in radio unit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.2RAURfLoopAvailableread-onlycurrent
xfRAUAtpcCapability
OBJECT-TYPE
This object indicates if the radio unit supports ATPC or not.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.3RAUAtpcCapabilityread-onlycurrent
xfRAULocalCtrlCapability
OBJECT-TYPE
This object indicates if the radio unit supports local transmit power control or not.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.4INTEGER {other(1), noLocalControlSupport(2), supportsLocalControl(3)}read-onlycurrent
xfRAUModCapability
OBJECT-TYPE
This object shows the modulation methods supported by the radio unit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.5RAUModCapabilityread-onlycurrent
xfRAUFrequencyband
OBJECT-TYPE
This object shows the frequency band for the radio unit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.6Unsigned32 (0..255)read-onlycurrent
xfRAUSubBand
OBJECT-TYPE
This object shows the sub band (Index) for the radio unit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.7Unsigned32 (0..255)read-writecurrent
xfRAUTemperature
OBJECT-TYPE
This object shows the temperature, in degree Celsius, inside the radio unit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.8Integer32 (-127..127)read-onlycurrent
xfRAUProtectionPath
OBJECT-TYPE
This object indicates what radio path the radio belongs to.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.9INTEGER {other(1), rauRa1(2), rauRa2(3)}read-onlycurrent
xfRAURxCapability
OBJECT-TYPE
This object indicates if the radio unit support RX configuration.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.10INTEGER {other(1), rxSupport(2)}read-onlycurrent
xfRAUNotes
OBJECT-TYPE
You can add information in this description field, for example polarization, antenna type or logging a site visit.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.11OCTET STRING (SIZE(0..800))read-writecurrent
xfRauAtpcVersion
OBJECT-TYPE
This object represents the RAU ATPC version.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.12INTEGER {other(1), version1(2), version2(3), version3(4)}read-onlycurrent
xfRauBoosterCapability
OBJECT-TYPE
This object represents the Booster capability for a link.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.13BoosterCapabilityread-onlycurrent
xfRauBoosterSelectedIndex
OBJECT-TYPE
This object represents the Booster selected index for a link.
1.3.6.1.4.1.193.81.3.4.3.1.1.1.14Integer32 (0..2147483647)read-writecurrent
xfRFIFTable
OBJECT-TYPE
Table for Radiolink point-to-point radios RF IF managed objects. Table indexed with ifIndex.
1.3.6.1.4.1.193.81.3.4.3.1.2not-accessiblecurrent
xfRFIFEntry
OBJECT-TYPE
An entry in the xfRFIFTable.
1.3.6.1.4.1.193.81.3.4.3.1.2.1not-accessiblecurrent
xfRFBaseTxFrequency
OBJECT-TYPE
This object shows the Tx frequency in KHz when frequency step number is 0.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.1Unsigned32 (0..4294967295)read-onlycurrent
xfRFBaseRxFrequency
OBJECT-TYPE
This object shows the Rx frequency in KHz when frequency. step number is 0
1.3.6.1.4.1.193.81.3.4.3.1.2.1.2Unsigned32 (0..4294967295)read-onlycurrent
xfRFStepSize
OBJECT-TYPE
This object shows the frequency step size in KHz.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.3Unsigned32 (0..65535)read-onlycurrent
xfRFStepLimitLow
OBJECT-TYPE
This object shows the lowest allowed frequency step number.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.4Unsigned32 (0..65535)read-onlycurrent
xfRFStepLimitHigh
OBJECT-TYPE
This object shows the highest allowed frequency step number.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.5Unsigned32 (0..65535)read-onlycurrent
xfRFCurrentStepNumber
OBJECT-TYPE
This object sets/shows the frequency step number. 0 = frequency not yet defined. For Classic RAUs, TX and RX frequencies can not be set individually. The span between them is always fixed and depends on different frequency and sub band. - To calculate step number for TX and RX, use the following formulas: New step number = (TX frequency - XfRAUBaseTxFrequency) / XfRAUStepSize New step number = (RX frequency - xfRAUBaseRxFrequency) / XfRAUStepSize - To calculate TX and RX frequencies, use the following formulas: TX frequency = XfRAUBaseTxFrequency + XfRAUCurrentStepNumber * XfRAUStepSize RX frequency = XfRAUBaseRxFrequency + XfRAUCurrentStepNumber * XfRAUStepSize For Agile RAUs, the TX and RX frequencies can be set individually. Above formulas are only valid for TX frequency. For RX frequency, xfRFCurrentStepNumberRx must be used. Default value: 0
1.3.6.1.4.1.193.81.3.4.3.1.2.1.6Unsigned32 (0..65535)read-writecurrent
xfRFTxOperStatus
OBJECT-TYPE
This object shows the operational status of the transmitter.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.7RFTxOperStatusread-onlycurrent
xfRFTxAdminStatus
OBJECT-TYPE
This object sets the desired status of the transmitter. Value other(1) not settable. Especially for far end: txOff(2), requests far end transmitter to be turned off. txOn(3), requests far end transmitter to be turned on. Default value: txOff(2) - near end. other(1) - far end.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.8INTEGER {other(1), txOff(2), txOn(3)}read-writecurrent
xfRFLoopEnable
OBJECT-TYPE
This object manage RF loop. Default value: disable(3). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.9INTEGER {other(1), enable(2), disable(3)}read-writecurrent
xfRFAlarms
OBJECT-TYPE
This TC enumerates the alarms for RF interface. txFrequency - Transmitter frequency synthesizer loop is unlocked. rxFrequency - Receiver frequency synthesizer loop is unlocked. rfOutputLevel - Major degradation of transmitter output power is detected. rxAfc - The frequency of the received signal is outside the range of the Automatic Frequency Control in the RAU receiver. rfInputLevel - Receiver RF input signal level has dropped below the threshold for the receiver. rfInputThreshold - The RF input level has dropped below the xfRFInputAlarmThreshold. rfOutputLevelATPC - The transmitter output power has been continuously at 'Patpc,max' for too long. This can occur due to several reasons: * The operator has set 'Patpc,max' too low. * The hop attenuation has increased (steady-state). * The transmitter PA is v. * The LNA in Rx is deteriorating.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.10Bits {txFrequency0(0), txFrequency1(1), txFrequency2(2), rxFrequency0(3), rxFrequency1(4), rxFrequency2(5), rfOutputLevel0(6), rfOutputLevel1(7), rfOutputLevel2(8), rxAfc0(9), rxAfc1(10), rxAfc2(11), rfInputLevel0(12), rfInputLevel1(13), rfInputLevel2(14), rfInputThreshold0(15), rfInputThreshold1(16), rfInputThreshold2(17), rfOutputLevelATPC0(18), rfOutputLevelATPC1(19), rfOutputLevelATPC2(20), sdcRfInputLevelMain0(21), sdcRfInputLevelMain1(22), sdcRfInputLevelMain2(23), sdcRfInputLevelDiv0(24), sdcRfInputLevelDiv1(25), sdcRfInputLevelDiv2(26), rlts1Counter15m0(27), rlts1Counter15m1(28), rlts1Counter15m2(29), rlts2Counter15m0(30), rlts2Counter15m1(31), rlts2Counter15m2(32), rltmCounter15m0(33), rltmCounter15m1(34), rltmCounter15m2(35), tlts1Counter15m0(36), tlts1Counter15m1(37), tlts1Counter15m2(38), tltmCounter15m0(39), tltmCounter15m1(40), tltmCounter15m2(41), rlts1Counter24h0(42), rlts1Counter24h1(43), rlts1Counter24h2(44), rlts2Counter24h0(45), rlts2Counter24h1(46), rlts2Counter24h2(47), rltmCounter24h0(48), rltmCounter24h1(49), rltmCounter24h2(50), tlts1Counter24h0(51), tlts1Counter24h1(52), tlts1Counter24h2(53), tltmCounter24h0(54), tltmCounter24h1(55), tltmCounter24h2(56), remoteRfIfHighestSeverityAlarm0(57), remoteRfIfHighestSeverityAlarm1(58), remoteRfIfHighestSeverityAlarm2(59), ifcabledamaged0(60), ifcabledamaged1(61), ifcabledamaged2(62)}read-onlycurrent
xfRFStatus
OBJECT-TYPE
This object shows the RAU status. rfLoop - Warns if RF-loop is enabled on RAU txOff - Warns if TX is manually set to off
1.3.6.1.4.1.193.81.3.4.3.1.2.1.11Bits {rfLoop0(0), rfLoop1(1), rfLoop2(2), txOff0(3), txOff1(4), txOff2(5)}read-onlycurrent
xfRFStepSizeRx
OBJECT-TYPE
This object shows the Rx frequency step size in KHz.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.12Unsigned32 (0..65535)read-onlycurrent
xfRFStepLimitLowRx
OBJECT-TYPE
This object shows the Rx lowest allowed frequency step number.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.13Unsigned32 (0..65535)read-onlycurrent
xfRFStepLimitHighRx
OBJECT-TYPE
This object shows the Rx highest allowed frequency step number.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.14Unsigned32 (0..65535)read-onlycurrent
xfRFCurrentStepNumberRx
OBJECT-TYPE
This object sets/shows the RX frequency step number for Agile RAUs. 0 = frequency not yet defined. - To calculate step number for RX, use the following formula: New step number Rx = (RX frequency - xfRAUBaseRxFrequency) / XfRAUStepSizeRx - To calculate RX frequency, use the following formula: RX frequency = XfRAUBaseRxFrequency + XfRAUCurrentStepNumberRx * XfRAUStepSizeRx Default value: 0
1.3.6.1.4.1.193.81.3.4.3.1.2.1.15Unsigned32 (0..65535)read-writecurrent
xfRFDuplexType
OBJECT-TYPE
This object tells the duplex frequency mode for the RAU: - fixed: Tx frequency only can be set by operator, Rx frequency is automatically set on the basis of (fixed) RAU duplex frequency - variable: duplex frequency can be configured by operator
1.3.6.1.4.1.193.81.3.4.3.1.2.1.16INTEGER {other(1), fixed(2), variable(3)}read-onlycurrent
xfRFDuplexConfig
OBJECT-TYPE
This object enables setting of duplex frequency for the RAU. It is always disabled(3) and can not be overwritten if xfRFDuplexType = fixed(2).
1.3.6.1.4.1.193.81.3.4.3.1.2.1.17INTEGER {other(1), enabled(2), disabled(3)}read-writecurrent
xfRFDuplexDistance
OBJECT-TYPE
This object is aimed to select the duplex distance for the RAU. It can only be set if xfRFDuplexConfig = enabled(2), so that: xfRFDuplexDistance = Tx Frequency - Rx Frequency Otherwise, it is automatically filled on the basis of Tx and Rx frequency settings, and can not be overwritten.
1.3.6.1.4.1.193.81.3.4.3.1.2.1.18Integer32 (-2147483647..2147483647)read-writecurrent
xfRFPowerTable
OBJECT-TYPE
Table for Radiolink point-to-point radios managed objects. Table indexed with ifIndex.
1.3.6.1.4.1.193.81.3.4.3.1.3not-accessiblecurrent
xfRFPowerEntry
OBJECT-TYPE
An entry in the xfRFPowerTable.
1.3.6.1.4.1.193.81.3.4.3.1.3.1not-accessiblecurrent
xfRFCurrentOutputPower
OBJECT-TYPE
This object shows the output power in dBm including attenuator.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.1Integer32 (-100..45 | 255)read-onlycurrent
xfRFRtpcMinOutputPower
OBJECT-TYPE
This object shows the minimum output power in dBm including attenuator. Value -100 indicate that RAU Tx on is not possible due to power supply limitations.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.2Integer32 (-100..45 | 255)read-onlycurrent
xfRFRtpcMaxOutputPower
OBJECT-TYPE
This object shows the maximum output power in dBm including attenuator. Value -100 indicate that RAU Tx on is not possible due to power supply limitations.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.3Integer32 (-100..45 | 255)read-onlycurrent
xfRFRtpcSelectedOutputPower
OBJECT-TYPE
This object set/shows the selected output power in dBm including attenuator. Value 254 indicates that the selected power is set to maximum. Default value: 254
1.3.6.1.4.1.193.81.3.4.3.1.3.1.4Integer32 (-100..45 | 254)read-writecurrent
xfRFAtpcMinOutputPower
OBJECT-TYPE
This object shows the minimum output power in dBm in ATPC. mode for radio contained in the radio terminal.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.5Integer32 (-100..45 | 255)read-onlycurrent
xfRFAtpcMaxOutputPower
OBJECT-TYPE
This object sets/shows the ATPC maximum output power in dBm for radio contained in the radio terminal. Value 254 indicates that the power is set to maximum. Default value: 254.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.6Integer32 (-100..45 | 254)read-writecurrent
xfRFAtpcMinInputPowerFar
OBJECT-TYPE
This object shows the ATPC minimum input target power level for far end radio.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.7Integer32 (-99..-30 | 255)read-onlycurrent
xfRFAtpcSelectedInputPowerFar
OBJECT-TYPE
This object sets/shows the ATPC selected input target level for far end radio. Default value: -30.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.8Integer32 (-99..-30)read-writecurrent
xfRFAttenuator
OBJECT-TYPE
This object sets/shows the value in dBm for fixed attenuator mounted in antenna. Default value: 0.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.9Integer32 (0..100)read-writecurrent
xfRFCurrentInputPower
OBJECT-TYPE
This object shows RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
1.3.6.1.4.1.193.81.3.4.3.1.3.1.10Integer32 (-999..-200)read-onlycurrent
xfRFMaxInputPowerLast7Days
OBJECT-TYPE
This object shows maximum RF input level last 7 days. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.11Integer32 (-999..-200 | 0)read-onlycurrent
xfRFMinInputPowerLast7Days
OBJECT-TYPE
This object shows minimum RF input level last 7 days. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.12Integer32 (-999..-200 | 0)read-onlycurrent
xfRFMaxInputPowerSinceReset
OBJECT-TYPE
This object shows maximum RF input level since reset. RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
1.3.6.1.4.1.193.81.3.4.3.1.3.1.13Integer32 (-999..-200)read-onlycurrent
xfRFMinInputPowerSinceReset
OBJECT-TYPE
This object shows minimum RF input level since reset. RF input level = value/10 dBm. Domain: [-20.0 .. -99.9 dBm].
1.3.6.1.4.1.193.81.3.4.3.1.3.1.14Integer32 (-999..-200)read-onlycurrent
xfRFInputPowerReset
OBJECT-TYPE
This object reset the registers for the RF input level and All Time High level this seven days period and counters for the next seven days period of time Note. For protected rlMLE and rlXfMLE terminals this command will reset both Ra1 and Ra2 values. Near end access: read-write Far end access: read-write (Traffic Node only)
1.3.6.1.4.1.193.81.3.4.3.1.3.1.15INTEGER {inputPowerReset(1)}read-writecurrent
xfRFInputAlarmThreshold
OBJECT-TYPE
This object shows RF input level threshold. Default value: -93.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.16Integer32 (-99..-30)read-writecurrent
xfRFOutputPower4QAM
OBJECT-TYPE
Output power for 4QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.17Integer32read-onlycurrent
xfRFOutputPower8QAM
OBJECT-TYPE
Output power for 8QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.18Integer32read-onlycurrent
xfRFOutputPower16QAM
OBJECT-TYPE
Output power for 16QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.19Integer32read-onlycurrent
xfRFOutputPower32QAM
OBJECT-TYPE
Output power for 32QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.20Integer32read-onlycurrent
xfRFOutputPower64QAM
OBJECT-TYPE
Output power for 64QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.21Integer32read-onlycurrent
xfRFOutputPower128QAM
OBJECT-TYPE
Output power for 128QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.22Integer32read-onlycurrent
xfRFOutputPower256QAM
OBJECT-TYPE
Output power for 256QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.23Integer32read-onlycurrent
xfRFOutputPower512QAM
OBJECT-TYPE
Output power for 512QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.24Integer32read-onlycurrent
xfRFAtpcFallbackOutputPower
OBJECT-TYPE
This object sets maximum output power in dBm in ATPCFallback mode for radio contained in the radio terminal. Value = 254 indicates that the power is set to maximum. Default value: 254.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.25Integer32 (-100..45 | 254)read-writecurrent
xfRFAtpcFallbackEnable
OBJECT-TYPE
Enable/disable ATPCFallback.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.26ATPCFallbackEnableread-writecurrent
xfRFAtpcFallbackTimer
OBJECT-TYPE
ATPC Fallback Timer specifies how long the output power can be at PATPC, MAX before ATPC fallback is triggered Default value: 15 min
1.3.6.1.4.1.193.81.3.4.3.1.3.1.27Integer32 (1..60)read-writecurrent
xfRFOutputPower1024QAM
OBJECT-TYPE
Output power for 1024QAM.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.28Integer32read-onlycurrent
xfRFMaxOutputPowerNotLimited
OBJECT-TYPE
Max output power in dBm including attenuator that the RAU can give if it is not power supply limited.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.29Integer32read-onlycurrent
xfRFMaxOutputPowerNotPossible
OBJECT-TYPE
unknown(0) isPossible(1) Max output power is possible due to power supply limitations isNotPossible(2) Max output power is not possible due to power supply limitations
1.3.6.1.4.1.193.81.3.4.3.1.3.1.30INTEGER {unknown(0), isPossible(1), isNotPossible(2)}read-onlycurrent
xfRFCurrentInputPowerSdcMain
OBJECT-TYPE
This object shows RF input level for SDC Main path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
1.3.6.1.4.1.193.81.3.4.3.1.3.1.31Integer32 (-999..-200 | 0)read-onlycurrent
xfRFCurrentInputPowerSdcDiv
OBJECT-TYPE
This object shows RF input level for SDC Diversity path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
1.3.6.1.4.1.193.81.3.4.3.1.3.1.32Integer32 (-999..-200 | 0)read-onlycurrent
xfRFMeanInputPower1m
OBJECT-TYPE
This object shows RF input mean level for last minute. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm] 0 (zero) indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.33Integer32 (-999..-200 | 0)read-onlycurrent
xfRFMaxOutputPowerLast7Days
OBJECT-TYPE
This object shows maximum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.34Integer32 (-100..45 | 255)read-onlycurrent
xfRFMinOutputPowerLast7Days
OBJECT-TYPE
This object shows minimum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.35Integer32 (-100..45 | 255)read-onlycurrent
xfRFMaxOutputPowerSinceReset
OBJECT-TYPE
This object shows maximum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.36Integer32 (-100..45 | 255)read-onlycurrent
xfRFMinOutputPowerSinceReset
OBJECT-TYPE
This object shows minimum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.37Integer32 (-100..45 | 255)read-onlycurrent
xfRFMaxMSELast7Days
OBJECT-TYPE
Indicate Max MSE level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.38Integer32 (-1000..1000 | 2000)read-onlycurrent
xfRFMinMSELast7Days
OBJECT-TYPE
Indicate Min MSE level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.39Integer32 (-1000..1000 | 2000)read-onlycurrent
xfRFMaxXPILast7Days
OBJECT-TYPE
Indicate Max Cross-Polar Interference (XPI) level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.40Integer32 (-1000..1000 | 2000)read-onlycurrent
xfRFMinXPILast7Days
OBJECT-TYPE
Indicate Min Cross-Polar Interference (XPI) level last 7 days. Input level = value/10 dB. Domain: [-100.0 ... 100.0 dB] 2000 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.41Integer32 (-1000..1000 | 2000)read-onlycurrent
xfRFOutputPowerReset
OBJECT-TYPE
This object reset the registers for the RF output level and All Time High level this seven days period and counters for the next seven days period of time.
1.3.6.1.4.1.193.81.3.4.3.1.3.1.42INTEGER {outputPowerReset(1)}read-writecurrent
xfRFBoosterGain
OBJECT-TYPE
Value of the Gain of the Booster
1.3.6.1.4.1.193.81.3.4.3.1.3.1.43Integer32 (0..255)read-onlycurrent
xfRFBoosterMaxInputPower
OBJECT-TYPE
Value of the Max Input Power admitted towards the Booster
1.3.6.1.4.1.193.81.3.4.3.1.3.1.44Integer32 (-100..35 | 255)read-onlycurrent
xfRFBoosterCapability
OBJECT-TYPE
Value of Booster capability according to the system
1.3.6.1.4.1.193.81.3.4.3.1.3.1.45BoosterCapabilityread-onlycurrent
xfRFBoosterProductNumber
OBJECT-TYPE
Product Number of the Booster connected to the specific RF IF
1.3.6.1.4.1.193.81.3.4.3.1.3.1.46DisplayString (SIZE(0..20))read-writecurrent
xfRFBoosterHWRevision
OBJECT-TYPE
HW Revision of the Booster connected to the specific RF IF
1.3.6.1.4.1.193.81.3.4.3.1.3.1.47DisplayString (SIZE(0..20))read-writecurrent
xfRAUCapabilityTable
OBJECT-TYPE
Table for RAU capability information. Table indexed with entPhysicalIndex and xfTermRowIndex.
1.3.6.1.4.1.193.81.3.4.3.1.4not-accessiblecurrent
xfRAUCapabilityEntry
OBJECT-TYPE
An entry in xfRAUCapabilityTable.
1.3.6.1.4.1.193.81.3.4.3.1.4.1not-accessiblecurrent
xfRAUChannelSpacing
OBJECT-TYPE
Channel spacing. ETSI: 3.5, 7, 14, 28, 40, 56 MHz ANSI: 10, 20, 30, 40, 50 MHz
1.3.6.1.4.1.193.81.3.4.3.1.4.1.1RAUChannelSpacingCapabilityread-onlycurrent
xfRAUChannelModulation
OBJECT-TYPE
This object shows the modulation. Values: cqpsk(2) CQPSK qam16(3) 16-QAM qam128(4) 128-QAM qam32(5) 32-QAM qam64(6) 64-QAM qam4(7) 4-QAM qam8(8) 8-QAM qam256(9) 256-QAM qam512(10) 512-QAM qam1024(11) 1024-QAM
1.3.6.1.4.1.193.81.3.4.3.1.4.1.2RAUModulationread-onlycurrent
xfRAUSpectrumEfficiencyClass
OBJECT-TYPE
Spectrum Efficiency Class: other(1), unknown sec2(2), Spectrum eff. Class 2 sec3(3), Spectrum eff. Class 3 sec4L(4), Spectrum eff. Class 4L sec4H(5), Specturm eff. Class 4H sec5A(6), Spectrum eff. Class 5A sec5B(7), Spectrum eff. Class 5B sec6A(8), Spectrum eff. Class 6A sec6B(9) Spectrum eff. Class 6B
1.3.6.1.4.1.193.81.3.4.3.1.4.1.3RauSecread-onlycurrent
xfRAUCarrierMode
OBJECT-TYPE
Radio carrier mode.
1.3.6.1.4.1.193.81.3.4.3.1.4.1.4INTEGER {singleCarrier(1), xpicDualCarrier(2), mimoMultiCarrier(3)}read-onlycurrent
xfRAUSubBandTable
OBJECT-TYPE
Table for RAU Sub-Band index capability. Table indexed with entPhysicalIndex and xfRAUSubBandIndex.
1.3.6.1.4.1.193.81.3.4.3.1.5not-accessiblecurrent
xfRAUSubBandEntry
OBJECT-TYPE
An entry in xfRAUSubBandTable.
1.3.6.1.4.1.193.81.3.4.3.1.5.1not-accessiblecurrent
xfRAUSubBandIndex
OBJECT-TYPE
An index for the specific RAU Sub-Band available index range.
1.3.6.1.4.1.193.81.3.4.3.1.5.1.1Unsigned32 (1..255)read-onlycurrent
xfRAUSubBandRange
OBJECT-TYPE
This object shows the RAU Sub-Band available index range [0..255].
1.3.6.1.4.1.193.81.3.4.3.1.5.1.2Unsigned32 (0..255)read-onlycurrent
xfRFSpectrumDiagTable
OBJECT-TYPE
Table for RF Spectrum Diagnostics control and status
1.3.6.1.4.1.193.81.3.4.3.1.6not-accessiblecurrent
xfRFSpectrumDiagEntry
OBJECT-TYPE
An entry in xfRFSpectrumDiagTable
1.3.6.1.4.1.193.81.3.4.3.1.6.1not-accessiblecurrent
xfRFSpectrumDiagAdminStatus
OBJECT-TYPE
RF Spectrum Diagnostics Admin Status
1.3.6.1.4.1.193.81.3.4.3.1.6.1.1INTEGER {other(1), channelScanStart(2), subBandScanStart(3), scanStop(255)}read-writecurrent
xfRFSpectrumDiagOperStatus
OBJECT-TYPE
RF Spectrum Diagnostics Oper Status
1.3.6.1.4.1.193.81.3.4.3.1.6.1.2INTEGER {scanNotStarted(0), subBandScanOngoing(1), channelScanOngoing(2), scanCanceled(3), subBandScanFinished(4), channelScanFinished(5)}read-onlycurrent
xfRFSpectrumDiagChannelScanEstTime
OBJECT-TYPE
Estimated time in seconds for scanning one Channel Spacing at current RX frequency
1.3.6.1.4.1.193.81.3.4.3.1.6.1.3Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagSubBandScanEstTime
OBJECT-TYPE
Estimated time in seconds for scanning full Sub Band of connected RAU
1.3.6.1.4.1.193.81.3.4.3.1.6.1.4Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagScanDate
OBJECT-TYPE
Date and time when scan (channel or sub-band) is completed, format: [YYYY]-[MM]-[DD]T[hh]:[mm]:[ss]
1.3.6.1.4.1.193.81.3.4.3.1.6.1.5DisplayString (SIZE(0..32))read-onlycurrent
xfRFSpectrumDiagChannelSpacing
OBJECT-TYPE
Channel width measured by Spectrum Diagnostics
1.3.6.1.4.1.193.81.3.4.3.1.6.1.6Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagCurrRxFrequency
OBJECT-TYPE
Current value of Rx frequency
1.3.6.1.4.1.193.81.3.4.3.1.6.1.7Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagMinRxFrequency
OBJECT-TYPE
Minimum sub-band Rx frequency (RAU lower edge)
1.3.6.1.4.1.193.81.3.4.3.1.6.1.8Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagMaxRxFrequency
OBJECT-TYPE
Maximum sub-band Rx frequency (RAU upper edge)
1.3.6.1.4.1.193.81.3.4.3.1.6.1.9Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagIdxCompanion1
OBJECT-TYPE
RF IF index for 1st companion carrier (0 if no companion)
1.3.6.1.4.1.193.81.3.4.3.1.6.1.10Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagIdxCompanion2
OBJECT-TYPE
RF IF index for 2nd companion carrier (0 if no companion)
1.3.6.1.4.1.193.81.3.4.3.1.6.1.11Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagIdxCompanion3
OBJECT-TYPE
RF IF index for 3rd companion carrier (0 if no companion)
1.3.6.1.4.1.193.81.3.4.3.1.6.1.12Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagProgress
OBJECT-TYPE
Completed percentage of Spectrum Diagnostics scan
1.3.6.1.4.1.193.81.3.4.3.1.6.1.13Unsigned32 (0..100)read-onlycurrent
xfRFSpectrumDiagResultTable
OBJECT-TYPE
Table of Spectrum Diagnostics scan results
1.3.6.1.4.1.193.81.3.4.3.1.7not-accessiblecurrent
xfRFSpectrumDiagResultEntry
OBJECT-TYPE
An entry in xfRFSpectrumDiagResultTable
1.3.6.1.4.1.193.81.3.4.3.1.7.1not-accessiblecurrent
xfRFSpectrumDiagResultIndex
OBJECT-TYPE
Spectrum Diagnostics Scan Result Index
1.3.6.1.4.1.193.81.3.4.3.1.7.1.1Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagResultRxFrequency
OBJECT-TYPE
Spectrum Diagnostics Scan Result Rx frequency in kHz
1.3.6.1.4.1.193.81.3.4.3.1.7.1.2Unsigned32 (0..4294967295)read-onlycurrent
xfRFSpectrumDiagResultRxPower
OBJECT-TYPE
Spectrum Diagnostics Scan Result Rx Power value/10 dBm Domain: [-99.9 .. -20.0 dBm]
1.3.6.1.4.1.193.81.3.4.3.1.7.1.3Integer32 (-999..-200)read-onlycurrent
xfRfIfPowerTable
OBJECT-TYPE
Table for Radio Link RAU managed objects. Table indexed with ifIndex.
1.3.6.1.4.1.193.81.3.4.3.1.8not-accessiblecurrent
xfRfIfPowerEntry
OBJECT-TYPE
An entry in the xfRfIfPowerTable.
1.3.6.1.4.1.193.81.3.4.3.1.8.1not-accessiblecurrent
xfRfSelectedMinOutputPower
OBJECT-TYPE
Minimum output power in dBm (selected by operator). Default value: 10 dBm.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.1RfOutputPowerread-writecurrent
xfRfSelectedMaxOutputPower
OBJECT-TYPE
Maximum output power in dBm (selected by operator). Default value: 10 dBm.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.2RfOutputPowerread-writecurrent
xfRfCurrentOutputPower
OBJECT-TYPE
Current output power in dBm. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.3RfOutputPowerread-onlycurrent
xfRfMinOutputPower
OBJECT-TYPE
Minimum output power in dBm (provided by RAU). 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.4RfOutputPowerread-onlycurrent
xfRfMaxOutputPower
OBJECT-TYPE
Maximum output power in dBm (provided by RAU). 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.5RfOutputPowerread-onlycurrent
xfRfAtpcTargetInputPowerFE
OBJECT-TYPE
ATPC target input power on Far End side. Default value: -30.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.6Integer32 (-99..-30)read-writecurrent
xfRfCurrentInputPower
OBJECT-TYPE
RF input level. Value is in 1/10 dBm. Domain: [-20.0 .. -99.9 dBm].
1.3.6.1.4.1.193.81.3.4.3.1.8.1.7RfInputPowerread-onlycurrent
xfRfMaxInputPowerLast7Days
OBJECT-TYPE
Maximum RF input level in the last 7 days. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.8RfInputPowerread-onlycurrent
xfRfMinInputPowerLast7Days
OBJECT-TYPE
Minimum RF input level in the last 7 days. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.9RfInputPowerread-onlycurrent
xfRfMaxInputPowerSinceReset
OBJECT-TYPE
Maximum RF input level since reset. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.10RfInputPowerread-onlycurrent
xfRfMinInputPowerSinceReset
OBJECT-TYPE
Minimum RF input level since reset. Value is in 1/10 dBm. Domain: [-99.9 ... -20.0 dBm]. 0 (zero) indicates an invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.11RfInputPowerread-onlycurrent
xfRfInputPowerReset
OBJECT-TYPE
This object resets the registers for: - RF input power levels - input levels (i.e. RF power, MSE and XPI) in the next 7 days period of time.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.12INTEGER {other(1), inputPowerNoReset(2), inputPowerReset(3)}read-writecurrent
xfRfInputAlarmThreshold
OBJECT-TYPE
RF input level threshold. Default value: -93.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.13Integer32 (-99..-30)read-writecurrent
xfRfOutputPower4QAM
OBJECT-TYPE
Output power for 4QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.14RfOutputPowerread-onlycurrent
xfRfOutputPower16QAM
OBJECT-TYPE
Output power for 16QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.15RfOutputPowerread-onlycurrent
xfRfOutputPower32QAM
OBJECT-TYPE
Output power for 32QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.16RfOutputPowerread-onlycurrent
xfRfOutputPower64QAM
OBJECT-TYPE
Output power for 64QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.17RfOutputPowerread-onlycurrent
xfRfOutputPower128QAM
OBJECT-TYPE
Output power for 128QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.18RfOutputPowerread-onlycurrent
xfRfOutputPower256QAM
OBJECT-TYPE
Output power for 256QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.19RfOutputPowerread-onlycurrent
xfRfOutputPower512QAM
OBJECT-TYPE
Output power for 512QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.20RfOutputPowerread-onlycurrent
xfRfOutputPower1024QAM
OBJECT-TYPE
Output power for 1024QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.21RfOutputPowerread-onlycurrent
xfRfOutputPower2048QAM
OBJECT-TYPE
Output power for 2048QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.22RfOutputPowerread-onlycurrent
xfRfOutputPower4096QAM
OBJECT-TYPE
Output power for 4096QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.23RfOutputPowerread-onlycurrent
xfRfMaxOutputPowerNotLimited
OBJECT-TYPE
Max output power in dBm that the RAU can give if it is not power supply limited. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.24RfOutputPowerread-onlycurrent
xfRfMaxOutputPowerPossible
OBJECT-TYPE
possible(2): max output power is possible. notPossible(3): max output power is not possible, due to power supply limitations.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.25INTEGER {other(1), possible(2), notPossible(3)}read-onlycurrent
xfRfMeanInputPower1m
OBJECT-TYPE
This object shows RF input mean level for last minute. RF input level = value/10 dBm. Domain: [-99.9 ... -20.0 dBm] 0 (zero) indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.26Integer32 (-999..-200 | 0)read-onlycurrent
xfRfMaxOutputPowerLast7Days
OBJECT-TYPE
This object shows maximum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.27Integer32 (-100..45 | 255)read-onlycurrent
xfRfMinOutputPowerLast7Days
OBJECT-TYPE
This object shows minimum RF output level last 7 days. RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.28Integer32 (-100..45 | 255)read-onlycurrent
xfRfMaxOutputPowerSinceReset
OBJECT-TYPE
This object shows maximum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.29Integer32 (-100..45 | 255)read-onlycurrent
xfRfMinOutputPowerSinceReset
OBJECT-TYPE
This object shows minimum RF output level since reset RF output level = value dBm. Domain: [-100 ... 45 dBm] 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.30Integer32 (-100..45 | 255)read-onlycurrent
xfRfOutputPowerReset
OBJECT-TYPE
This object reset the registers for the RF output level and All Time High level this seven days period and counters for the next seven days period of time.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.31INTEGER {other(1), outputPowerNoReset(2), outputPowerReset(3)}read-writecurrent
xfRfAvailableOutputPowerType
OBJECT-TYPE
This object reports the output power capability of the RAU: - standardPower - highPower
1.3.6.1.4.1.193.81.3.4.3.1.8.1.32INTEGER {other(1), standardPower(2), highPower(3)}read-onlycurrent
xfRfSelectedOutputPowerType
OBJECT-TYPE
This object allows setting the output power type: - standardPower - highPower default: standardPower(2) When the type is set to highPower(3) a HP license key is required. If the license key is not present the capacity is limited to Basic Capacity. The output power can be configured as 'normal' without any impact from the HP license key (present or not). When the mode is standardPower(2) the availableMaxOutputPower is limited to 'max power' - 4 dB per modulation.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.33INTEGER {other(1), standardPower(2), highPower(3)}read-writecurrent
xfRfTaps
OBJECT-TYPE
This object allows setting the Traffic Aware Power Saving. Default: disabled(3)
1.3.6.1.4.1.193.81.3.4.3.1.8.1.34INTEGER {other(1), enabled(2), disabled(3), notAvailable(4)}read-writecurrent
xfRfCurrentInputPowerSdcMain
OBJECT-TYPE
This object shows RF input level for SDC Main path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
1.3.6.1.4.1.193.81.3.4.3.1.8.1.35RfInputPowerread-onlycurrent
xfRfCurrentInputPowerSdcDiv
OBJECT-TYPE
This object shows RF input level for SDC Diversity path = value/10 dBm. Domain: [-20.0 .. -99.9 dBm]. 0 (zero) indicates invalid value (e.g. SDC not available).
1.3.6.1.4.1.193.81.3.4.3.1.8.1.36RfInputPowerread-onlycurrent
xfRfOutputPower8192QAM
OBJECT-TYPE
Output power for 8192QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.37RfOutputPowerread-onlycurrent
xfRfOutputPower16384QAM
OBJECT-TYPE
Output power for 16384QAM. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.38RfOutputPowerread-onlycurrent
xfRfAtpcFallbackOutputPower
OBJECT-TYPE
This object sets output power (in dBm) in ATPCFallback mode, for radio contained in the Carrier Termination. 255 indicates invalid value.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.39RfOutputPowerread-writecurrent
xfRfAtpcFallbackEnable
OBJECT-TYPE
Enable/disable ATPCFallback.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.40ATPCFallbackEnableread-writecurrent
xfRfAtpcFallbackTimer
OBJECT-TYPE
This object specifies how long the output power can be at (ATPC, MAX) before ATPC fallback is triggered. Default value: ETSI 15 min, ANSI 5 min.
1.3.6.1.4.1.193.81.3.4.3.1.8.1.41Integer32 (1..60)read-writecurrent
xfRFIFCableMonitoringTable
OBJECT-TYPE
Table for Radiolink point-to-point radios RF IF Cable Monitoring managed objects. Table indexed with ifIndex.
1.3.6.1.4.1.193.81.3.4.3.1.9not-accessiblecurrent
xfRFIFCableMonitoringEntry
OBJECT-TYPE
An entry in the xfRFIFCableMonitoringTable.
1.3.6.1.4.1.193.81.3.4.3.1.9.1not-accessiblecurrent
xfRFIFCMStatus
OBJECT-TYPE
This object manage IfCable Monitoring Status. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.1INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFOutlierAgc
OBJECT-TYPE
This object manage IfCable Outlier Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.2INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFOutlierSetTh
OBJECT-TYPE
This object handles Set Threshold for Outlier Alarm. 3 = Default value (0.3). - To calculate threshold use the following formula: SetTh/10. Default value: 3 Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.3Unsigned32 (0..65535)read-writecurrent
xfRFOutlierCeaseTh
OBJECT-TYPE
This object handles Cease Threshold for Outlier Alarm. 2 = Default value (0.2). - To calculate threshold use the following formula: SetTh/10. Default value: 2 Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.4Unsigned32 (0..65535)read-writecurrent
xfRFRangeAgc
OBJECT-TYPE
This object manage IfCable Range Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.5INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFRangeSetTh
OBJECT-TYPE
This object handles Set Threshold for Range Alarm. 30 = Default value (3). - To calculate threshold use the following formula: SetTh/10. Default value: 30 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.6Unsigned32 (0..65535)read-writecurrent
xfRFRangeCeaseTh
OBJECT-TYPE
This object handles Cease Threshold for Range Alarm. 20 = Default value (2). - To calculate threshold use the following formula: SetTh/10. Default value: 20 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.7Unsigned32 (0..65535)read-writecurrent
xfRFStddevAgc
OBJECT-TYPE
This object manage IfCable Stddev Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.8INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFStddevSetTh
OBJECT-TYPE
This object handles Set Threshold for Stddev Alarm. 50 = Default value (5). - To calculate threshold use the following formula: SetTh/10. Default value: 50 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.9Unsigned32 (0..65535)read-writecurrent
xfRFStddevCeaseTh
OBJECT-TYPE
This object handles Cease Threshold for Stddev Alarm. 20 = Default value (2). - To calculate threshold use the following formula: SetTh/10. Default value: 20 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.10Unsigned32 (0..65535)read-writecurrent
xfRFDegradationAgc
OBJECT-TYPE
This object manage IfCable Degradation Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.11INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFDegradationSetTh
OBJECT-TYPE
This object handles Set Threshold for Degradation Alarm. 2 = Default value (0.2). - To calculate threshold use the following formula: SetTh/10. Default value: 2 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.12Unsigned32 (0..65535)read-writecurrent
xfRFDegradationCeaseTh
OBJECT-TYPE
This object handles Cease Threshold for Degradation Alarm. 1 = Default value (0.1). - To calculate threshold use the following formula: SetTh/10. Default value: 1 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.13Unsigned32 (0..65535)read-writecurrent
xfRFMarginAgc
OBJECT-TYPE
This object manage IfCable Margin Alarm. Default value: disable(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.14INTEGER {other(1), disable(2), enable(3)}read-writecurrent
xfRFMarginSetTh
OBJECT-TYPE
This object handles Set Threshold for Margin Alarm. 30 = Default value (3). - To calculate threshold use the following formula: SetTh/10. Default value: 30 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.15Unsigned32 (0..65535)read-writecurrent
xfRFMarginCeaseTh
OBJECT-TYPE
This object handles Cease Threshold for Margin Alarm. 60 = Default value (6). - To calculate threshold use the following formula: SetTh/10. Default value: 60 (dB/10) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.16Unsigned32 (0..65535)read-writecurrent
xfRFOutlierValue
OBJECT-TYPE
This object handles the value calculated on 24h for Outlier Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.17Integer32 (-2147483647..2147483647)read-onlycurrent
xfRFRangeValue
OBJECT-TYPE
This object handles the value calculated on 24h for Range Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.18Integer32 (-2147483647..2147483647)read-onlycurrent
xfRFStddevValue
OBJECT-TYPE
This object handles the value calculated on 24h for Stddev Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.19Integer32 (-2147483647..2147483647)read-onlycurrent
xfRFDegradationValue
OBJECT-TYPE
This object handles the value calculated on 24h for Degradation Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.20Integer32 (-2147483647..2147483647)read-onlycurrent
xfRFMarginValue
OBJECT-TYPE
This object handles the value calculated on 24h for Margin Alarm. 0 = Default value (0). - To calculate value use the following formula: Value/100. Default value: 0 (dB/100) Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.21Integer32 (-2147483647..2147483647)read-onlycurrent
xfRFOutlierTrigger
OBJECT-TYPE
This object manage IfCable Outlier Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.22INTEGER {other(1), noSetThreshold(2), setThreshold(3)}read-onlycurrent
xfRFRangeTrigger
OBJECT-TYPE
This object manage IfCable Range Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.23INTEGER {other(1), noSetThreshold(2), setThreshold(3)}read-onlycurrent
xfRFStddevTrigger
OBJECT-TYPE
This object manage IfCable Stddev Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.24INTEGER {other(1), noSetThreshold(2), setThreshold(3)}read-onlycurrent
xfRFDegradationTrigger
OBJECT-TYPE
This object manage IfCable Degradation Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.25INTEGER {other(1), noSetThreshold(2), setThreshold(3)}read-onlycurrent
xfRFMarginTrigger
OBJECT-TYPE
This object manage IfCable Margin Trigger. Default value: noSetThreshold(2). Near end access: read-write. Far end access: no access.
1.3.6.1.4.1.193.81.3.4.3.1.9.1.26INTEGER {other(1), noSetThreshold(2), setThreshold(3)}read-onlycurrent
xfSdcTable
OBJECT-TYPE
Table for SDC capabilities, setting and status.
1.3.6.1.4.1.193.81.3.4.3.1.10not-accessiblecurrent
xfSdcEntry
OBJECT-TYPE
An entry in the xfSdcTable.
1.3.6.1.4.1.193.81.3.4.3.1.10.1not-accessiblecurrent
xfSdcCapability
OBJECT-TYPE
SDC capability, including both MMU and ODU.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.1INTEGER {other(1), sdcSupported(2), sdcNotSupported(3)}read-onlycurrent
xfSdcAdminStatus
OBJECT-TYPE
SDC Admin Status.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.2INTEGER {other(1), sdcEnabled(2), sdcDisabled(3)}read-writecurrent
xfSdcOperStatus
OBJECT-TYPE
SDC Oper Status.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.3INTEGER {other(1), sdcEnabled(2), sdcDisabled(3), sdcInProgress(4)}read-onlycurrent
xfSdcDadeControl
OBJECT-TYPE
SDC DADE procedure control.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.4INTEGER {other(1), sdcDadeStart(2), sdcDadeAbort(3)}read-writecurrent
xfSdcDadeStatus
OBJECT-TYPE
SDC DADE procedure status.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.5INTEGER {other(1), sdcCalibrated(2), sdcNotCalibrated(3), sdcCalInProgress(4), sdcCalMismatch(5)}read-onlycurrent
xfSdcPath
OBJECT-TYPE
SDC selected path (desired value).
1.3.6.1.4.1.193.81.3.4.3.1.10.1.6INTEGER {other(1), sdcAuto(2), sdcMain(3), sdcDiv(4)}read-writecurrent
xfSdcOduDateTimeCalibration
OBJECT-TYPE
Date and time of the SDC DADE calibration for the ODU with serial number in xfSdcOduSerialNumber. Format: [YYYY]-[MM]-[DD]T[hh]:[mm]:[ss] (ISO 8601).
1.3.6.1.4.1.193.81.3.4.3.1.10.1.7DisplayString (SIZE(0..255))read-onlycurrent
xfSdcOduSerialNumber
OBJECT-TYPE
Serial number of the ODU the current value of xfSdcOduDateTimeCalibration is referred to.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.8DisplayString (SIZE(0..255))read-onlycurrent
xfSdcGain
OBJECT-TYPE
SDC gain in dB/10. Domain: [0.0 .. 3.0 dB].
1.3.6.1.4.1.193.81.3.4.3.1.10.1.9Integer32 (0..30)read-onlycurrent
xfSdcActualPath
OBJECT-TYPE
SDC actual path (current value).
1.3.6.1.4.1.193.81.3.4.3.1.10.1.10INTEGER {other(1), sdcAuto(2), sdcMain(3), sdcDiv(4)}read-onlycurrent
xfSdcDadeDelay
OBJECT-TYPE
DADE delay in nsec.
1.3.6.1.4.1.193.81.3.4.3.1.10.1.11Integer32 (-2147483647..2147483647)read-onlycurrent
xfRadioLinkPtpRadioConformance
OBJECT-IDENTITY
1.3.6.1.4.1.193.81.3.4.3.2
xfRadioLinkPtpRadioCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.193.81.3.4.3.2.1
xfRadioLinkPtpRadioGroups
OBJECT-IDENTITY
1.3.6.1.4.1.193.81.3.4.3.2.2

Conformance

NameOIDStatus
xfRADIOLINKPTPRADIOFullCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement everything.
1.3.6.1.4.1.193.81.3.4.3.2.1.1current
xfRadioLinkPtpRadioCompleteGroup
OBJECT-GROUP
A collection of all current objects in this MIB module.
1.3.6.1.4.1.193.81.3.4.3.2.2.1current