UBQS-INTERFACE-MIB
- Registered at
- 1.3.6.1.4.1.7800.100.4
- Last updated
- 2009-05-26 00:00
- Organization
- Ubiquoss Corp.
- Namespace
- ubiquoss
- Source file
UBQS-INTERFACE-MIB- Digest
sha256:a164a9d7a1ceff8bab001cf1c172268ce6006e6d08adcf7b2ffe8621ea1c6973
Description
A MIB module for the physical interface in IF-MIB (RFC2863).
Contact
Ubiquoss Customer Service Postal: 24F Milennium B/D, 467-12, Dogok-Dong, GangNam-Gu, Seoul 135-270 Korea Tel: 82-2-2190-3100
Imports
| From | Symbols |
|---|---|
| ENTITY-MIB | entPhysicalIndex |
| IF-MIB | InterfaceIndexOrZero, ifAdminStatus, ifIndex, ifName, ifOperStatus, ifType |
| Q-BRIDGE-MIB | VlanIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
| UBQS-SMI | ubiMgmtv2 |
| UBQS-TC | IfOperStatusReason, UbiBridgeId, UbiPortList, Unsigned64 |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB ENTITY-MIB IANA-ENTITY-MIB IANAifType-MIB IF-MIB P-BRIDGE-MIB Q-BRIDGE-MIB RFC1158-MIB RFC1271-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC TOKEN-RING-RMON-MIB UBQS-INTERFACE-MIB UBQS-SMI UBQS-TC UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| PortGBICTypeList TEXTUAL-CONVENTION Represents the type of slot. | current | |||
| PortType TEXTUAL-CONVENTION Represents the port type. | current | |||
| UbiFlowctrlWatermark TEXTUAL-CONVENTION represent flowcontrol watermark value : '3d 3d' -------------------------- first value = wmpause(0-255) second value = wmcancel(0-255) | current | |||
| UbiSwitchportType TEXTUAL-CONVENTION A port type. The possible port types are: customerVlanPort(0) - Indicates a port is a C-tag aware port of an enterprise VLAN aware bridge. providerNetworkPort(1) - Indicates a port is an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections within a PBN or PBBN. customerNetworkPort(2) - Indicates a port is an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections to the exterior of a PBN or PBBN. customerEdgePort(3) - Indicates a port is a C-tag aware port of a Provider Bridge used for connections to the exterior of a PBN or PBBN. customerBackbonePort(4) - Indicates a port is a I-tag aware port of a Backbone Edge Bridge's B-component. virtualInstancePort(5) - Indicates a port is a virtual S-tag aware port within a Backbone Edge Bridge's I-component which is responsible for handling S-tagged traffic for a specific backbone service instance. dBridgePort(6) - Indicates a port is a VLAN-unaware member of an 802.1D bridge. access(7) trunk(8) hybrid(9) | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ubiInterfaceMIBNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.0 | |||
| ubiInterfaceNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.0.0 | |||
| ubiTrafficControlNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.0.1 | |||
| ubiInterfaceMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1 | |||
| ubiIfNotificationEnables OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.1 | |||
| ubiGrp1 OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.1.1 | |||
| ubiLinkUpDownEnabled OBJECT-TYPE This variable indicates whether the system produces the notification of linkup/down. | 1.3.6.1.4.1.7800.100.4.1.1.1.1 | TruthValue | read-write | current |
| ubiGrp2 OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.1.2 | |||
| ubiPortAutoNegoFaultEnabled OBJECT-TYPE This variable indicates whether the system produces the notification of the auto negotiation failure for a particular physical port. | 1.3.6.1.4.1.7800.100.4.1.1.2.1 | TruthValue | read-write | current |
| ubiLoadMonitorAlarmEnabled OBJECT-TYPE This variable indicates whether the system produces the notification of ubiLoadMonitorRisingAlarm and ubiLoadMonitorFallingAlarm. | 1.3.6.1.4.1.7800.100.4.1.1.2.2 | Bits {input(0), crc(1), error(2), drop(3), output(4)} | read-write | current |
| ubiTrafficControlAlarmEnabled OBJECT-TYPE This variable indicates whether the system produces the notification of ubiTrafficControlRisingAlarm and ubiTrafficControlFallingAlarm. | 1.3.6.1.4.1.7800.100.4.1.1.2.3 | TruthValue | read-write | current |
| ubiPortTable OBJECT-TYPE This table contains objects which provide more information about physical interface. | 1.3.6.1.4.1.7800.100.4.1.2 | not-accessible | current | |
| ubiPortEntry OBJECT-TYPE An entry containing management information applicable to a particular physical interface. | 1.3.6.1.4.1.7800.100.4.1.2.1 | not-accessible | current | |
| ubiPortName OBJECT-TYPE The physical port name. | 1.3.6.1.4.1.7800.100.4.1.2.1.1 | DisplayString | read-only | current |
| ubiPortType OBJECT-TYPE The type of the physical port. | 1.3.6.1.4.1.7800.100.4.1.2.1.2 | PortType | read-only | current |
| ubiPortOperStatus OBJECT-TYPE The current operational status of the port. down(1) is down up(2) is up disable(3) is administratively down | 1.3.6.1.4.1.7800.100.4.1.2.1.3 | INTEGER {down(1), up(2), disable(3)} | read-only | current |
| ubiPortDuplex OBJECT-TYPE Indicates whether the port is operating in half- duplex, full-duplex or auto negotiation mode. | 1.3.6.1.4.1.7800.100.4.1.2.1.4 | INTEGER {half(1), full(2), auto(3)} | read-only | current |
| ubiPortSpeed OBJECT-TYPE The current operational speed of the port. | 1.3.6.1.4.1.7800.100.4.1.2.1.5 | INTEGER {auto(0), speed_10(10), speed_100(100), speed_1000(1000), speed_2500(2500), speed_10000(10000), speed_40000(40000)} | read-only | current |
| ubiPortAdminDuplex OBJECT-TYPE The desired duplex of the port. | 1.3.6.1.4.1.7800.100.4.1.2.1.6 | INTEGER {half(1), full(2), auto(3)} | read-write | current |
| ubiPortAdminSpeed OBJECT-TYPE The desired speed of the port. | 1.3.6.1.4.1.7800.100.4.1.2.1.7 | INTEGER {auto(0), speed_10(10), speed_100(100), speed_1000(1000), speed_2500(2500), speed_10000(10000), speed_40000(40000)} | read-write | current |
| ubiPortMtu OBJECT-TYPE The MTU value of the port. | 1.3.6.1.4.1.7800.100.4.1.2.1.8 | Integer32 (1500..10218) | read-write | current |
| ubiPortL2L3IfState OBJECT-TYPE The operational mode of the port whether the port is layer 2 or layer 3. | 1.3.6.1.4.1.7800.100.4.1.2.1.9 | INTEGER {routed(1), switchport(2)} | read-write | current |
| ubiPortAutoNegoFaultState OBJECT-TYPE The link is down due to auto negotiation failure. This state indicates the state of auto negotiation failure for a particular port. But it's used for notification only. | 1.3.6.1.4.1.7800.100.4.1.2.1.10 | INTEGER {ok(1), fail(2)} | accessible-for-notify | current |
| ubiPortReset OBJECT-TYPE Reset the physical port. | 1.3.6.1.4.1.7800.100.4.1.2.1.11 | INTEGER {none(0), reset(1)} | read-write | current |
| ubiPortLocalSwitching OBJECT-TYPE Port local-switching | 1.3.6.1.4.1.7800.100.4.1.2.1.12 | INTEGER {disable(0), enable(1)} | read-write | current |
| ubiPortExt OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.3 | |||
| ubiPortExtTable OBJECT-TYPE This table contains objects which provide more information about physical interface. | 1.3.6.1.4.1.7800.100.4.1.3.1 | not-accessible | current | |
| ubiPortExtEntry OBJECT-TYPE An entry containing management information applicable to a particular physical interface. | 1.3.6.1.4.1.7800.100.4.1.3.1.1 | not-accessible | current | |
| ubiPortGBICStatus OBJECT-TYPE The current operational status of the equipped slot. | 1.3.6.1.4.1.7800.100.4.1.3.1.1.1 | INTEGER {none(0), in(1), out(2)} | read-only | current |
| ubiPortGBICType OBJECT-TYPE The current GBIC Type of the equipped slot. none(0): unequipped other(1) : equipped, none of the following list sfp(2) xfp(3) sfp-plus(4) | 1.3.6.1.4.1.7800.100.4.1.3.1.1.2 | PortGBICTypeList | read-only | current |
| ubiPortGBICSerialNumber OBJECT-TYPE The serial number of this GBIC. | 1.3.6.1.4.1.7800.100.4.1.3.1.1.3 | DisplayString | read-only | current |
| ubiSwitchPort OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.4 | |||
| ubiSwitchportTable OBJECT-TYPE A table contains the information for switchport. | 1.3.6.1.4.1.7800.100.4.1.4.1 | not-accessible | current | |
| ubiSwitchportEntry OBJECT-TYPE A list of information for each switchport. | 1.3.6.1.4.1.7800.100.4.1.4.1.1 | not-accessible | current | |
| ubiSwitchportName OBJECT-TYPE A textual string containing information about the interface. | 1.3.6.1.4.1.7800.100.4.1.4.1.1.1 | DisplayString | read-only | current |
| ubiSwitchportMode OBJECT-TYPE A port type. The possible port types are: customerVlanPort(0) - Indicates a port is a C-tag aware port of an enterprise VLAN aware bridge. providerNetworkPort(1) - Indicates a port is an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections within a PBN or PBBN. customerNetworkPort(2) - Indicates a port is an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections to the exterior of a PBN or PBBN. customerEdgePort(3) - Indicates a port is a C-tag aware port of a Provider Bridge used for connections to the exterior of a PBN or PBBN. customerBackbonePort(4) - Indicates a port is a I-tag aware port of a Backbone Edge Bridge's B-component. virtualInstancePort(5) - Indicates a port is a virtual S-tag aware port within a Backbone Edge Bridge's I-component which is responsible for handling S-tagged traffic for a specific backbone service instance. dBridgePort(6) - Indicates a port is a VLAN-unaware member of an 802.1D bridge. access(7) trunk(8) hybrid(9) | 1.3.6.1.4.1.7800.100.4.1.4.1.1.2 | UbiSwitchportType | read-write | current |
| ubiSwitchportBridgeId OBJECT-TYPE This object is used to allocate the bridge group id. | 1.3.6.1.4.1.7800.100.4.1.4.1.1.3 | UbiBridgeId | read-write | current |
| ubiSwitchportVlanNative OBJECT-TYPE The native vlan of a switchport. | 1.3.6.1.4.1.7800.100.4.1.4.1.1.4 | VlanIndex | read-write | current |
| ubiSwitchportVlanDefault OBJECT-TYPE The default vlan of a switchport. | 1.3.6.1.4.1.7800.100.4.1.4.1.1.5 | VlanIndex | read-write | current |
| ubiSwitchPortVlanControlTable OBJECT-TYPE This table contains the control information of vlan for switchport. | 1.3.6.1.4.1.7800.100.4.1.4.2 | not-accessible | current | |
| ubiSwitchPortVlanControlEntry OBJECT-TYPE A list of vlan control for each switchport. | 1.3.6.1.4.1.7800.100.4.1.4.2.1 | not-accessible | current | |
| ubiSwitchportVlanTaggedSet OBJECT-TYPE The operational set of the switchport for a specific tagged vlan. If a value of set is all(4), the vlan index should be a zero. | 1.3.6.1.4.1.7800.100.4.1.4.2.1.1 | INTEGER {other(0), add(1), delete(2), except(3), all(4), none(5)} | read-write | current |
| ubiSwitchportVlanUntaggedSet OBJECT-TYPE The operational set of the switchport for a specific untagged vlan. If a value of set is all(4), the vlan index should be a zero. | 1.3.6.1.4.1.7800.100.4.1.4.2.1.2 | INTEGER {other(0), add(1), delete(2)} | read-write | current |
| ubiSwitchportVlanEgressTaggedSet OBJECT-TYPE The operational set of the switchport for a egress tagged vlan. | 1.3.6.1.4.1.7800.100.4.1.4.2.1.3 | INTEGER {enable(1), disable(2)} | read-write | current |
| ubiSwitchVlanStackingTable OBJECT-TYPE This table contains the stacking information of vlan for switchport. | 1.3.6.1.4.1.7800.100.4.1.4.3 | not-accessible | current | |
| ubiSwitchVlanStackingEntry OBJECT-TYPE A list of vlan stacking for each switchport. | 1.3.6.1.4.1.7800.100.4.1.4.3.1 | not-accessible | current | |
| ubiVlanStackingMode OBJECT-TYPE vlan-stacking mode | 1.3.6.1.4.1.7800.100.4.1.4.3.1.1 | INTEGER {disable(0), customerEdgePort(1), providerPort(2)} | read-write | current |
| ubiVlanStackingEthertype OBJECT-TYPE vlan-stacking ethertype (format : 0xhhhh) | 1.3.6.1.4.1.7800.100.4.1.4.3.1.2 | DisplayString | read-write | current |
| ubiPortTrafficControl OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.5 | |||
| ubiLoadMonitorTable OBJECT-TYPE This table contains the information of load monitoring. | 1.3.6.1.4.1.7800.100.4.1.5.1 | not-accessible | current | |
| ubiLoadMonitorEntry OBJECT-TYPE A list of load monitoring configuration. | 1.3.6.1.4.1.7800.100.4.1.5.1.1 | not-accessible | current | |
| ubiLoadMonitorType OBJECT-TYPE This object specifies the type of load monitoring. For example, If type is input, ubiLoadMonitorVariable should be the particular variable related to the input statistics. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.1 | INTEGER {input(1), crc(2), error(3), drop(4), output(5), storm-control-discard(6)} | read-only | current |
| ubiLoadMonitorInterval OBJECT-TYPE The monitoring interval. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.2 | Integer32 | read-create | current |
| ubiLoadMonitorVariable OBJECT-TYPE The object identifier of the particular variable to be sampled for load monitoring. this variable is decided by ubiLoadMonitorType. variable mapping information for load monitoring: type object identifier --------------- ------------------------- INPUT ifHCInOctets (64bit) OUTPUT ifHCOutOctets (64bit) CRC ubiIfStatsInCRCErrors (64bit) DISCARD ifInDiscards (32bit) ERROR ifInErrors (32bit) STORM-DISCARD ubiStormTotalDiscards (64bit) | 1.3.6.1.4.1.7800.100.4.1.5.1.1.3 | OBJECT IDENTIFIER | read-only | current |
| ubiLoadMonitorValue OBJECT-TYPE The sampling value of the statistic for the particular variable. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.4 | Counter64 | read-only | current |
| ubiLoadMonitorCriticalThreshold OBJECT-TYPE The critical threshold for the sampled statistics. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.5 | Integer32 | read-create | current |
| ubiLoadMonitorMajorThreshold OBJECT-TYPE The major threshold for the sampled statistics. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.6 | Integer32 | read-create | current |
| ubiLoadMonitorUnit OBJECT-TYPE The unit of the sampled statistics and threshold value. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.7 | DisplayString | read-only | current |
| ubiLoadMonitorAlarmType OBJECT-TYPE The alarm type. This object is used for notification only. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.8 | INTEGER {none(0), critical(1), major(2)} | accessible-for-notify | current |
| ubiLoadMonitorRowStatus OBJECT-TYPE The row status of this entry. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.9 | RowStatus | read-create | current |
| ubiLoadMonitorAlarmZone OBJECT-TYPE This object indicates the current alarm zone. | 1.3.6.1.4.1.7800.100.4.1.5.1.1.10 | INTEGER {normal(0), critical(1), major(2)} | accessible-for-notify | current |
| ubiTrafficControl OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.5.2 | |||
| ubiTrafficControlConfig OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.5.2.1 | |||
| ubiTrafficControlReportInterval OBJECT-TYPE Interval when alarm is up/down according to traffic count | 1.3.6.1.4.1.7800.100.4.1.5.2.1.1 | INTEGER {default(1)} | read-write | current |
| ubiTrafficControlObservingPeriod OBJECT-TYPE Period for counting traffic | 1.3.6.1.4.1.7800.100.4.1.5.2.1.2 | INTEGER {default(1)} | read-write | current |
| ubiTrafficControlHighAlarmMode OBJECT-TYPE Action that is operated when traffic is over high-threshold | 1.3.6.1.4.1.7800.100.4.1.5.2.1.3 | INTEGER {repeatable(0), once(1), disable(2)} | read-write | current |
| ubiTrafficControlLowAlarmMode OBJECT-TYPE Action that is operated when traffic is below low-threshold | 1.3.6.1.4.1.7800.100.4.1.5.2.1.4 | INTEGER {once(1), disable(2)} | read-write | current |
| ubiTrafficControlTable OBJECT-TYPE The table for traffic-control configuration | 1.3.6.1.4.1.7800.100.4.1.5.2.2 | not-accessible | current | |
| ubiTrafficControlEntry OBJECT-TYPE The entry representing traffic-control config. Index description a) ubiTrafficControlIfindex : interface index b) ubiTrafficControlBaseType : base type of traffic value - pps(1), kbps(2) c) ubiTrafficControlTrafficType : type of traffic value - all(1), unicast(2), broadcast(3), multicast(4) d) ubiTrafficControlDirection : direction of traffic value - inbound(1), outbound(2) | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1 | not-accessible | current | |
| ubiTrafficControlIfindex OBJECT-TYPE A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.1 | Integer32 | read-only | current |
| ubiTrafficControlBaseType OBJECT-TYPE Base type of traffic. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.2 | INTEGER {pps(1), kbps(2)} | read-only | current |
| ubiTrafficControlType OBJECT-TYPE Type of traffic. Type based on KBPS must be only all(0). remains are only for pps. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.3 | INTEGER {all(1), broadcast(2), multicast(3), unicast(4)} | read-only | current |
| ubiTrafficControlDirection OBJECT-TYPE Direction of traffic. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.4 | INTEGER {inbound(1), outbound(2)} | read-only | current |
| ubiTrafficControlHighThreshold OBJECT-TYPE Traffic high-threshold. Type based on KBPS could has threshold less than 1000000. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.5 | Integer32 (1..1500000) | read-create | current |
| ubiTrafficControlLowThreshold OBJECT-TYPE Traffic low-threshold. Type based on KBPS could has threshold less than 1000000. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.6 | Integer32 (1..1500000) | read-create | current |
| ubiTrafficControlAction OBJECT-TYPE Traffic action type. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.7 | INTEGER {alarmOnly(1), blockMode(2)} | read-create | current |
| ubiTrafficControlStatus OBJECT-TYPE Interface's current status. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.8 | INTEGER {normal(1), alarm(2), block(3)} | read-only | current |
| ubiTrafficControlAverageRate OBJECT-TYPE Average rate of controlled traffic. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.9 | DisplayString | read-only | current |
| ubiTrafficControlOneMinRate OBJECT-TYPE Rate of controlled traffic per 1 minute. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.10 | DisplayString | read-only | current |
| ubiTrafficControlAlarmCount OBJECT-TYPE Number of alarmed times. | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.11 | Integer32 | read-only | current |
| ubiTrafficControlLastAlarmTime OBJECT-TYPE Last alarmed time | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.12 | DisplayString | read-only | current |
| ubiTrafficControlRowStatus OBJECT-TYPE Row Status | 1.3.6.1.4.1.7800.100.4.1.5.2.2.1.13 | RowStatus | read-create | current |
| ubiClearTrafficControl OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.5.2.3 | |||
| ubiClearTrafficControlInterface OBJECT-TYPE If value is 0, clear all interface. If value is ifindex, clear specific interface (only physical interface) | 1.3.6.1.4.1.7800.100.4.1.5.2.3.1 | Integer32 | read-write | current |
| ubiClearTrafficControlBaseType OBJECT-TYPE Traffic-control base type. 'none' value means all base type. | 1.3.6.1.4.1.7800.100.4.1.5.2.3.2 | INTEGER {none(0), pps(1), kbps(2)} | read-write | current |
| ubiClearTrafficControlType OBJECT-TYPE Traffic-control type. Type based on KBPS must be all. 'none' value means all traffic type. | 1.3.6.1.4.1.7800.100.4.1.5.2.3.3 | INTEGER {none(0), all(1), unicast(2), broadcast(3), multicast(4)} | read-write | current |
| ubiClearTrafficControlDirection OBJECT-TYPE Traffic-control direction. 'none' value means all direction. | 1.3.6.1.4.1.7800.100.4.1.5.2.3.4 | INTEGER {none(0), inbound(1), outbound(2)} | read-write | current |
| ubiClearTrafficControlOperate OBJECT-TYPE clear excute | 1.3.6.1.4.1.7800.100.4.1.5.2.3.5 | INTEGER {none(0), excute(1)} | read-write | current |
| ubiIfStatistics OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.6 | |||
| ubiIfEgressQueueStatsTable OBJECT-TYPE This table contains the information for egress queue statistics. | 1.3.6.1.4.1.7800.100.4.1.6.1 | not-accessible | current | |
| ubiIfEgressQueueStatsEntry OBJECT-TYPE A list of the port that configure cos feild. that port collects the pass and drop statistics for egress queue. | 1.3.6.1.4.1.7800.100.4.1.6.1.1 | not-accessible | current | |
| ubiIfEqStatsQueueId OBJECT-TYPE The queue identifier. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.1 | Integer32 (0..7) | not-accessible | current |
| ubiIfEqStatsPassOctets OBJECT-TYPE The pass counter for bytes. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.2 | Counter64 | read-only | current |
| ubiIfEqStatsDropOctets OBJECT-TYPE The drop counter for bytes. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.3 | Counter64 | read-only | current |
| ubiIfEqStatsPassPkts OBJECT-TYPE The pass counter for packets. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.4 | Counter | read-only | current |
| ubiIfEqStatsDropPkts OBJECT-TYPE The drop counter for packets. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.5 | Counter | read-only | current |
| ubiIfEqStatsQueueDescr OBJECT-TYPE A textual string containing information about the interface's each queue. | 1.3.6.1.4.1.7800.100.4.1.6.1.1.6 | DisplayString | read-write | current |
| ubiIfStatsTable OBJECT-TYPE This table contains the statistics for physical port. | 1.3.6.1.4.1.7800.100.4.1.6.2 | not-accessible | current | |
| ubiIfStatsEntry OBJECT-TYPE A Entry contains the statistics of a particular physical port. | 1.3.6.1.4.1.7800.100.4.1.6.2.1 | not-accessible | current | |
| ubiIfStatsInPkts OBJECT-TYPE The number of input packets for a given physical port. | 1.3.6.1.4.1.7800.100.4.1.6.2.1.1 | Counter64 | read-only | current |
| ubiIfStatsOutPkts OBJECT-TYPE The number of output packets for a given physical interface. | 1.3.6.1.4.1.7800.100.4.1.6.2.1.2 | Counter64 | read-only | current |
| ubiIfStatsInCRCErrors OBJECT-TYPE The number of input CRC errors for a given interface. | 1.3.6.1.4.1.7800.100.4.1.6.2.1.3 | Counter64 | read-only | current |
| ubiIfStatsCounterClear OBJECT-TYPE Initialize the counter | 1.3.6.1.4.1.7800.100.4.1.6.2.1.14 | INTEGER {none(0), clear(1)} | read-write | current |
| ubiIfStatsSnmpClear OBJECT-TYPE Initialize the statistics in this table. | 1.3.6.1.4.1.7800.100.4.1.6.2.1.15 | INTEGER {none(0), clear(1)} | read-write | current |
| ubiTrafficRateTable OBJECT-TYPE traffic rate per interface | 1.3.6.1.4.1.7800.100.4.1.6.3 | not-accessible | current | |
| ubiTrafficRateEntry OBJECT-TYPE traffic rate per interface | 1.3.6.1.4.1.7800.100.4.1.6.3.1 | not-accessible | current | |
| ubiIfStatsInTrafficRate OBJECT-TYPE | 1.3.6.1.4.1.7800.100.4.1.6.3.1.1 | Counter64 | read-only | current |
| ubiIfStatsOutTrafficRate OBJECT-TYPE | 1.3.6.1.4.1.7800.100.4.1.6.3.1.2 | Counter64 | read-only | current |
| ubiPortControl OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.7 | |||
| ubiFlowControlTable OBJECT-TYPE The table of flowcontrol information on physical ports. | 1.3.6.1.4.1.7800.100.4.1.7.1 | not-accessible | current | |
| ubiFlowControlEntry OBJECT-TYPE An entry of flowcontrol information on physical port. | 1.3.6.1.4.1.7800.100.4.1.7.1.1 | not-accessible | current | |
| ubiFlowctrlReceive OBJECT-TYPE flowcontrol on receive. | 1.3.6.1.4.1.7800.100.4.1.7.1.1.1 | INTEGER {off(0), on(1)} | read-write | current |
| ubiFlowctrlSend OBJECT-TYPE flowcontrol on send | 1.3.6.1.4.1.7800.100.4.1.7.1.1.2 | INTEGER {off(0), on(1)} | read-write | current |
| ubiFlowctrlWatermark OBJECT-TYPE flowcontrol watermark value | 1.3.6.1.4.1.7800.100.4.1.7.1.1.3 | UbiFlowctrlWatermark | read-write | current |
| ubiRateLimit OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.7.2 | |||
| ubiRateLimitTable OBJECT-TYPE The table of rate-limit information on physical ports | 1.3.6.1.4.1.7800.100.4.1.7.2.1 | not-accessible | current | |
| ubiRateLimitEntry OBJECT-TYPE An entry of rate-limit information on physical port | 1.3.6.1.4.1.7800.100.4.1.7.2.1.1 | not-accessible | current | |
| ubiEgressTrafficRate OBJECT-TYPE egress traffic rate | 1.3.6.1.4.1.7800.100.4.1.7.2.1.1.1 | Integer32 (1..10000000) | read-write | current |
| ubiEgressBucketSize OBJECT-TYPE egress bucket size | 1.3.6.1.4.1.7800.100.4.1.7.2.1.1.2 | Integer32 (1..4095) | read-write | current |
| ubiIngressLevel OBJECT-TYPE ingress level, range from 0.01 to 100.00 | 1.3.6.1.4.1.7800.100.4.1.7.2.1.1.3 | DisplayString | read-write | current |
| ubiRateLimitQueueEgressTable OBJECT-TYPE The table of rate-limit q-egress information on physical ports | 1.3.6.1.4.1.7800.100.4.1.7.2.2 | not-accessible | current | |
| ubiRateLimitQueueEgressEntry OBJECT-TYPE An entry of rate-limit q-egress information on physical port | 1.3.6.1.4.1.7800.100.4.1.7.2.2.1 | not-accessible | current | |
| ubiQueueId OBJECT-TYPE queue id | 1.3.6.1.4.1.7800.100.4.1.7.2.2.1.1 | Integer32 (0..7) | not-accessible | current |
| ubiQueueEgressTrafficRate OBJECT-TYPE q-egress traffic rate | 1.3.6.1.4.1.7800.100.4.1.7.2.2.1.2 | Integer32 (1..10000000) | read-write | current |
| ubiQueueEgressBucketSize OBJECT-TYPE q-egress bucket size | 1.3.6.1.4.1.7800.100.4.1.7.2.2.1.3 | Integer32 (1..4095) | read-write | current |
| ubiStormControlTable OBJECT-TYPE The table of storm-control information on physical ports | 1.3.6.1.4.1.7800.100.4.1.7.3 | not-accessible | current | |
| ubiStormControlEntry OBJECT-TYPE An entry of storm-control information on physical port | 1.3.6.1.4.1.7800.100.4.1.7.3.1 | not-accessible | current | |
| ubiBroadcastLevel OBJECT-TYPE broadcast control level, range from 0.01 to 100.00 | 1.3.6.1.4.1.7800.100.4.1.7.3.1.1 | DisplayString | read-write | current |
| ubiMulticastLevel OBJECT-TYPE multicast control level, range from 0.01 to 100.00 | 1.3.6.1.4.1.7800.100.4.1.7.3.1.2 | DisplayString | read-write | current |
| ubiUnicastLevel OBJECT-TYPE unicast control level, range from 0.01 to 100.00 | 1.3.6.1.4.1.7800.100.4.1.7.3.1.3 | DisplayString | read-write | current |
| ubiStormDiscardStats OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.7.4 | |||
| ubiStormDiscardStatsClear OBJECT-TYPE Initialize the counters for discarded packet by Storm-Control. | 1.3.6.1.4.1.7800.100.4.1.7.4.1 | INTEGER {none(0), clear(1)} | read-write | current |
| ubiStormDiscardStatsTable OBJECT-TYPE This table contains the statistics of discarded packets by Storm-control on physical ports | 1.3.6.1.4.1.7800.100.4.1.7.4.2 | not-accessible | current | |
| ubiStormDiscardStatsEntry OBJECT-TYPE An entry of storm-control discard statistics on physical port | 1.3.6.1.4.1.7800.100.4.1.7.4.2.1 | not-accessible | current | |
| ubiStormUnicastDiscards OBJECT-TYPE The number of discarded Unicast packets by Storm-control for a given interface. | 1.3.6.1.4.1.7800.100.4.1.7.4.2.1.1 | Counter64 | read-only | current |
| ubiStormMulticastDiscards OBJECT-TYPE The number of discarded Multicast packets by Storm-control for a given interface. | 1.3.6.1.4.1.7800.100.4.1.7.4.2.1.2 | Counter64 | read-only | current |
| ubiStormBroadcastDiscards OBJECT-TYPE The number of discarded Broadcast packets by Storm-control for a given interface. | 1.3.6.1.4.1.7800.100.4.1.7.4.2.1.3 | Counter64 | read-only | current |
| ubiStormTotalDiscards OBJECT-TYPE The Total number of discarded packets by Storm-control for a given interface. | 1.3.6.1.4.1.7800.100.4.1.7.4.2.1.4 | Counter64 | read-only | current |
| ubiIfErps OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.1.8 | |||
| ubiIfErpsTable OBJECT-TYPE The table of ERPS information on interface. | 1.3.6.1.4.1.7800.100.4.1.8.1 | not-accessible | current | |
| ubiIfErpsEntry OBJECT-TYPE The entry of ERPS information on interface. | 1.3.6.1.4.1.7800.100.4.1.8.1.1 | not-accessible | current | |
| ubiIfErpsAggMinLink OBJECT-TYPE Minmum Link count to activate Port-channel in ERPS. - To activate Port-channel, actived members of port-channel must be minmum link count at least. | 1.3.6.1.4.1.7800.100.4.1.8.1.1.1 | Integer32 (1..8) | read-write | current |
| ubiInterfaceMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.2 | |||
| ubiInterfaceMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.2.1 | |||
| ubiInterfaceMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.4.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| ubiPortAutoNegoFault NOTIFICATION-TYPE A ubiPortAutoNegoFault notification is sent at auto negotiation failure for a particular physical port. | 1.3.6.1.4.1.7800.100.4.0.0.1 | current |
| ubiLoadMonitorRisingAlarm NOTIFICATION-TYPE A ubiLoadMonitorRisingAlarm notification is sent when the ubiLoadMonitorValue crosses its rising threshold. | 1.3.6.1.4.1.7800.100.4.0.1.1 | current |
| ubiLoadMonitorFallingAlarm NOTIFICATION-TYPE A ubiLoadMonitorRisingAlarm notification is sent when the ubiLoadMonitorValue crosses its falling threshold. | 1.3.6.1.4.1.7800.100.4.0.1.2 | current |
| ubiTrafficControlRisingAlarm NOTIFICATION-TYPE A ubiTrafficControlRisingAlarm is sent when ubiTrafficControlOneMinRate is greater than current threshold. | 1.3.6.1.4.1.7800.100.4.0.1.3 | current |
| ubiTrafficControlFallingAlarm NOTIFICATION-TYPE A ubiTrafficControlFallingAlarm is sent when ubiTrafficControlOneMinRate is less than current threshold. | 1.3.6.1.4.1.7800.100.4.0.1.4 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| ubiInterfaceMIBCompliance MODULE-COMPLIANCE The compliance statement for entities which implement the UBQS-INTERFACE-MIB | 1.3.6.1.4.1.7800.100.4.2.1.1 | current |
| ubiPortGroup OBJECT-GROUP A collection of objects containing information about physical port. | 1.3.6.1.4.1.7800.100.4.2.2.1 | current |
| ubiIfStatsGroup OBJECT-GROUP A collection of objects containing packet statistics for a given port. | 1.3.6.1.4.1.7800.100.4.2.2.2 | current |
| ubiSwitchportGroup OBJECT-GROUP A collection of objects containing the switchport information. | 1.3.6.1.4.1.7800.100.4.2.2.3 | current |