UBQS-ENTITY-MIB
- Registered at
- 1.3.6.1.4.1.7800.100.3
- Last updated
- 2009-06-16 00:00
- Organization
- Ubiquoss Corp.
- Namespace
- ubiquoss
- Source file
UBQS-ENTITY-MIB- Digest
sha256:b702449479c93d244612a6b5c4e2829b0192c27013e1835d5994e6f0bc5000eb
Description
The UBQS-ENTITY-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system listed in the Entity-MIB (RFC 2737) entPhysicalTable.
Contact
Ubiquoss Customer Service Postal: 24F Milennium B/D, 467-12, Dogok-Dong, GangNam-Gu, Seoul 135-270 Korea Tel: 82-2-2190-3100
Imports
| From | Symbols |
|---|---|
| ENTITY-MIB | entPhysicalContainedIn, entPhysicalDescr, entPhysicalIndex, entPhysicalName |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
| UBQS-SMI | ubiMgmtv2 |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ENTITY-MIB IANA-ENTITY-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UBQS-ENTITY-MIB UBQS-SMI UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ModuleOperType TEXTUAL-CONVENTION Operational module states. Valid values are : unknown(1) Module is not in one of other states normal operational states: ok(2) Module is operational. disabled(3) Module is administratively disabled. selfTest(6) Module is performing selfTest. failure states: failed(7) Module has failed due to some condition not stated above. dormant(12) Module is waiting for an external or internal event to become operational. | current | |||
| UbiSensorDataScale TEXTUAL-CONVENTION International System of Units (SI) prefixes. | current | |||
| UbiSensorDataType TEXTUAL-CONVENTION sensor measurement data types. valid values are: other(1): a measure other than those listed below unknown(2): unknown measurement, or arbitrary, relative numbers volts(3): electric potential amperes(4): electric current celsius(5): temperature dBm(6): dB relative to 1mW of power percentRH(8): percent relative humidity rpm(9): shaft revolutions per minute cmm(10),: cubic meters per minute (airflow) truthvalue(11): value takes { true(1), false(2) } specialEnum(12): value takes user defined enumerated values watts(13): power hertz(14): frequency | current | |||
| UbiSensorPrecision TEXTUAL-CONVENTION When in the range 1 to 9, SensorPrecision is the number of decimal places in the fractional part of a SensorValue fixed-point number. When in the range -8 to -1, SensorPrecision is the number of accurate digits in a SensorValue fixed-point number. SensorPrecision is 0 for non-fixed-point numbers. Agent implementors must choose a value for SensorPrecision so that the precision and accuracy of a SensorValue is correctly indicated. For example, a temperature sensor that can measure 0o to 100o C in 0.1o increments, +/- 0.05o, would have a SensorPrecision of 1, a SensorDataScale of units(0), and a SensorValue ranging from 0 to 1000. The SensorValue would be interpreted as (degrees C * 10). If that temperature sensor's precision were 0.1o but its accuracy were only +/- 0.5o, then the SensorPrecision would be 0. The SensorValue would be interpreted as degrees C. Another example: a fan rotation speed sensor that measures RPM from 0 to 10,000 in 100 RPM increments, with an accuracy of +50/-37 RPM, would have a SensorPrecision of -2, a SensorDataScale of units(9), and a SensorValue ranging from 0 to 10000. The 10s and 1s digits of SensorValue would always be 0. | current | |||
| UbiSensorValue TEXTUAL-CONVENTION Represent the sensor value | current | |||
| UbiSensorValue_cisco TEXTUAL-CONVENTION For sensors that measure voltsAC, voltsDC, amperes, watts, hertz, celsius, cmm this item is a fixed point number ranging from -999,999,999 to +999,999,999. Use the value -1000000000 to indicate underflow. Use the value +1000000000 to indicate overflow. Use SensorPrecision to indicate how many fractional digits the SensorValue has. For sensors that measure percentRH, this item is a number ranging from 0 to 100. For sensors that measure rpm, this item can take only nonnegative values, 0..999999999. For sensors of type truthvalue, this item can take only two values: true(1), false(2). For sensors of type specialEnum, this item can take any value in the range (-1000000000..1000000000), but the meaning of each value is specific to the sensor. For sensors of type other and unknown, this item can take any value in the range (-1000000000..1000000000), but the meaning of the values are specific to the sensor. Use Entity-MIB entPhysicalTable.entPhysicalVendorType to learn about the sensor type. | current | |||
| UbiTcConnectorType TEXTUAL-CONVENTION | current | |||
| UbiTcEncodingType TEXTUAL-CONVENTION | current | |||
| UbiTcIdentifier TEXTUAL-CONVENTION | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ubiEntityMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.1 | |||
| ubiEntityNotificationEnables OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.1.1 | |||
| ubiFRUControlEnabled OBJECT-TYPE This variable indicates whether the system produces the following notifications: ubiEntityFRUInserted, ubiEntityFRURemoved. A false value will prevent these notifications from being generated. | 1.3.6.1.4.1.7800.100.3.1.1.1 | TruthValue | read-write | current |
| ubiEntSensorThresholdNotificationEnabled OBJECT-TYPE This variable indicates whether the system produces the following notification: ubiEntSensorThreshold. A false value will prevent these notifications from being generated. | 1.3.6.1.4.1.7800.100.3.1.1.2 | TruthValue | read-write | current |
| ubiModuleTable OBJECT-TYPE This table contains one row per module entity. | 1.3.6.1.4.1.7800.100.3.1.2 | not-accessible | current | |
| ubiModuleEntry OBJECT-TYPE Information about a particular module entity. | 1.3.6.1.4.1.7800.100.3.1.2.1 | not-accessible | current | |
| ubiModuleId OBJECT-TYPE The unique module ID. | 1.3.6.1.4.1.7800.100.3.1.2.1.1 | INTEGER | read-only | current |
| ubiModuleType OBJECT-TYPE The textual type of this module. | 1.3.6.1.4.1.7800.100.3.1.2.1.2 | DisplayString | read-only | current |
| ubiModuleOperStatus OBJECT-TYPE The operational state of this module. | 1.3.6.1.4.1.7800.100.3.1.2.1.3 | ModuleOperType | read-only | current |
| ubiModuleStatusLastChangeTime OBJECT-TYPE The value of sysUpTime when ubiModuleOperStatus is changed. | 1.3.6.1.4.1.7800.100.3.1.2.1.4 | TimeStamp | read-only | current |
| ubiModuleSerialNumber OBJECT-TYPE The serial number of this module. | 1.3.6.1.4.1.7800.100.3.1.2.1.5 | DisplayString | read-only | current |
| ubiModuleSlotNumber OBJECT-TYPE This value is determined by the number of slot where the module is located. | 1.3.6.1.4.1.7800.100.3.1.2.1.6 | Integer32 | read-only | current |
| ubiModulePortNumber OBJECT-TYPE This value is determined by the number of port where the module is located. | 1.3.6.1.4.1.7800.100.3.1.2.1.7 | Integer32 | read-only | current |
| ubiModuleAction OBJECT-TYPE This object, when read, returns one of the following results: other(1): module permanently enabled Setting this object to one of the acceptable values gives the following results: other(1): gives an error reset(2): resets the module's control logic Setting this object to any other values results in an error. | 1.3.6.1.4.1.7800.100.3.1.2.1.8 | INTEGER {other(1), reset(2)} | read-write | current |
| ubiSlotTable OBJECT-TYPE This table contains one row per slot entity. | 1.3.6.1.4.1.7800.100.3.1.3 | not-accessible | current | |
| ubiSlotEntry OBJECT-TYPE Information about a particular slot entity. | 1.3.6.1.4.1.7800.100.3.1.3.1 | not-accessible | current | |
| ubiSlotModuleId OBJECT-TYPE The unique module ID. | 1.3.6.1.4.1.7800.100.3.1.3.1.1 | INTEGER | read-only | current |
| ubiSlotId OBJECT-TYPE The unique slot ID. | 1.3.6.1.4.1.7800.100.3.1.3.1.2 | INTEGER | read-only | current |
| ubiSlotType OBJECT-TYPE The textual type of this slot. | 1.3.6.1.4.1.7800.100.3.1.3.1.3 | DisplayString | read-only | current |
| ubiSlotOperStatus OBJECT-TYPE The status of this slot. | 1.3.6.1.4.1.7800.100.3.1.3.1.4 | ModuleOperType | read-only | current |
| ubiSlotPortNumber OBJECT-TYPE This value is determined by the number of port where the slot is located. | 1.3.6.1.4.1.7800.100.3.1.3.1.5 | Integer32 | read-only | current |
| ubiSlotSerialNumber OBJECT-TYPE The serial number of this slot. | 1.3.6.1.4.1.7800.100.3.1.3.1.6 | DisplayString | read-write | current |
| ubiExtSlot OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.1.4 | |||
| ubiIEEE1588SlotOperStatus OBJECT-TYPE The operational status of the slot for IEEE 1588 specification. | 1.3.6.1.4.1.7800.100.3.1.4.1 | INTEGER {equip(1), unequip(2)} | read-only | current |
| ubiMngSlotOperStatus OBJECT-TYPE The operational status of the slot for mng specification. | 1.3.6.1.4.1.7800.100.3.1.4.2 | INTEGER {equip(1), unequip(2)} | read-only | current |
| ubiTransceiver OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.1.5 | |||
| ubiEntitySensorTable OBJECT-TYPE This table contains objects which provide information about the transceiver sensor of physical entity. | 1.3.6.1.4.1.7800.100.3.1.5.1 | not-accessible | current | |
| ubiEntitySensorEntry OBJECT-TYPE An entry containing management information applicable to the transceiver sensor of a particular physical entity. | 1.3.6.1.4.1.7800.100.3.1.5.1.1 | not-accessible | current | |
| ubiEntSensorType OBJECT-TYPE This variable indicates the type of data reported by the entSensorValue. valid values are: other(1): a measure other than those listed below unknown(2): unknown measurement, or arbitrary, relative numbers voltsAC(3): electric potential voltsDC(4): electric potential amperes(5): electric current celsius(6): temperature dBm(7): dB relative to 1mW of power | 1.3.6.1.4.1.7800.100.3.1.5.1.1.1 | UbiSensorDataType | read-only | current |
| ubiEntSensorScale OBJECT-TYPE This variable indicates the exponent to apply to sensor values reported by entSensorValue. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.2 | UbiSensorDataScale | read-only | current |
| ubiEntSensorValue OBJECT-TYPE This variable reports the most recent measurement seen by the sensor. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.3 | UbiSensorValue | read-only | current |
| ubiEntSensorEventStatus OBJECT-TYPE This variable indicates the present current event status of the sensor. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.4 | INTEGER {none(0), normal(1), highAlarm(2), highWarning(3), lowWarning(4), lowAlarm(5)} | read-only | current |
| ubiEntSensorEventUpdateTime OBJECT-TYPE The value of sysUpTime when the status of entity sensor is changed. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.5 | TimeStamp | read-only | current |
| ubiEntSensorAlarmHighThreshold OBJECT-TYPE This variable indicates the value of the high alarm threshold. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.6 | UbiSensorValue | read-write | current |
| ubiEntSensorWarningHighThreshold OBJECT-TYPE This variable indicates the value of the high warning threshold. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.7 | UbiSensorValue | read-write | current |
| ubiEntSensorWarningLowThreshold OBJECT-TYPE This variable indicates the value of the low warning threshold. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.8 | UbiSensorValue | read-write | current |
| ubiEntSensorAlarmLowThreshold OBJECT-TYPE This variable indicates the value of the low alarm threshold. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.9 | UbiSensorValue | read-write | current |
| ubiEntSensorName OBJECT-TYPE This variable indicates the name of the sensor entity. | 1.3.6.1.4.1.7800.100.3.1.5.1.1.10 | DisplayString | read-only | current |
| ubiTransceiverInfoTable OBJECT-TYPE This table contains objects which provide information about the transceiver of physical entity. | 1.3.6.1.4.1.7800.100.3.1.5.2 | not-accessible | current | |
| ubiTransceiverInfoEntry OBJECT-TYPE An entry containing management information applicable to the transceiver of a particular physical entity. | 1.3.6.1.4.1.7800.100.3.1.5.2.1 | not-accessible | current | |
| ubiTcIdentifier OBJECT-TYPE This variable indicates the transceiver indentifier. valid value are: unknown(0), other(1), gbic(2), module(3), sfp(4), xbi(5), xenpak(6), xfp(7), xff(8), xfp_e(9), xpak(10), x2(11) | 1.3.6.1.4.1.7800.100.3.1.5.2.1.1 | UbiTcIdentifier | read-only | current |
| ubiTcVendorOUI OBJECT-TYPE This variable indicates a textual string containing information about the IEEE company ID of transceiver vendor | 1.3.6.1.4.1.7800.100.3.1.5.2.1.2 | DisplayString | read-only | current |
| ubiTcVendorName OBJECT-TYPE A textual string containing information about the transceiver name. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.3 | DisplayString | read-only | current |
| ubiTcVendorPartNumber OBJECT-TYPE A textual string containing information about the part number of the transceiver. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.4 | DisplayString | read-only | current |
| ubiTcVendorRevisionLevel OBJECT-TYPE A textual string containing information about the revision level of the transceiver part number. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.5 | DisplayString | read-only | current |
| ubiTcVendorSerialNumber OBJECT-TYPE This variable indicates a textual string containing information about the transceiver serial number. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.6 | DisplayString | read-only | current |
| ubiTcVendorManufacturingDate OBJECT-TYPE This variable indicates a manufacturing date of transceiver | 1.3.6.1.4.1.7800.100.3.1.5.2.1.7 | DisplayString | read-only | current |
| ubiTcWaveLength OBJECT-TYPE This variable indicates a wave length of transceiver. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.8 | Integer32 | read-only | current |
| ubiTcConnector OBJECT-TYPE This variable indicates a connector type of transceiver. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.9 | UbiTcConnectorType | read-only | current |
| ubiTcLength OBJECT-TYPE This variable indicates a length of transceiver. | 1.3.6.1.4.1.7800.100.3.1.5.2.1.10 | Integer32 | read-only | current |
| ubiTransceiverMonitoring OBJECT-TYPE This variable indicates whether the system produces the log and notification for transceiver sensor. | 1.3.6.1.4.1.7800.100.3.1.5.3 | TruthValue | read-write | current |
| ubiEntityMIBNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.2 | |||
| ubiFruNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.2.0 | |||
| ubiEntitySensorNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.2.1 | |||
| ubiEntityMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.3 | |||
| ubiEntityMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.3.1 | |||
| ubiEntityMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.3.3.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| ubiFRUInserted NOTIFICATION-TYPE The ubiEntityFRUInserted notification indicates that a FRU was inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, and the entPhysicalIndex of the FRU's container. | 1.3.6.1.4.1.7800.100.3.2.0.1 | current |
| ubiFRURemoved NOTIFICATION-TYPE The ubiEntityFRURemoved notification indicates that a FRU was removed. The varbind for this notification indicates the entPhysicalIndex of the removed FRU, and the entPhysicalIndex of the FRU's container. | 1.3.6.1.4.1.7800.100.3.2.0.2 | current |
| ubiEntSensorThreshold NOTIFICATION-TYPE The ubiEntSensorThreshold notification indicates that the status of transceiver sensor was changed. | 1.3.6.1.4.1.7800.100.3.2.1.1 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| ubiEntityMIBCompliance MODULE-COMPLIANCE An Entity-MIB implementation can implement this group to provide FRU status and control. | 1.3.6.1.4.1.7800.100.3.3.1.1 | current |
| ubiEntityMIBModuleGroup OBJECT-GROUP The collection of objects which are used to get the operational state and redundancy state of the modules | 1.3.6.1.4.1.7800.100.3.3.2.1 | current |
| ubiEntitySlotGroup NOTIFICATION-GROUP The collection of objects which are used to get the operational state and redundancy state of the slot. | 1.3.6.1.4.1.7800.100.3.3.2.2 | current |
| ubiEntityMIBNotificationGroup OBJECT-GROUP TThe collection of objects which are used to send a notification. | 1.3.6.1.4.1.7800.100.3.3.2.3 | current |
| ubiEntiryMIBIEEE1588SlotGroup OBJECT-GROUP The collection of objects which are used to get the operational state of the slot for IEEE 1588. | 1.3.6.1.4.1.7800.100.3.3.2.4 | current |
| ubiEntityMIBTransceiverGroup OBJECT-GROUP The collection of objects which are used to get the information of transceiver. | 1.3.6.1.4.1.7800.100.3.3.2.5 | current |