TRIPPLITE-12X
- Registered at
- 1.3.6.1.4.1.850.21.3.6.1.4.1.850.201.3.6.1.4.1.850.901.3.6.1.4.1.850.1001.3.6.1.4.1.850.1011.3.6.1.4.1.850.1031.3.6.1.4.1.850.104
- Last updated
- 2017-02-28 16:00
- Organization
- Tripp Lite
- Revisions
- 2017-02-28 16:00, 2015-07-29 00:00, 2014-10-17 09:30, 2014-09-18 10:00, 2014-08-06 08:30, 2014-05-08 08:30, 2014-04-09 10:00, 2013-10-30 13:00
- Namespace
- poweralert
- Source file
TRIPPLITE-12X- Digest
sha256:b808128dd3e62efd14028fc7d6aace4441d49d4fd138a65cdf7ab04f4c939b80
Description
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
Contact
Software Engineering Tripp Lite 1111 W. 35th St. Chicago, IL 60609
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso |
| SNMPv2-TC | AutonomousType, DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeInterval, TimeStamp, TruthValue, VariablePointer |
| TRIPPLITE | tripplite |
| UPS-MIB | NonNegativeInteger, PositiveInteger |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC TRIPPLITE TRIPPLITE-12X UPS-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| tlEnumerations OBJECT-IDENTITY | 1.3.6.1.4.1.850.2 | |||
| tlOperatingSystems OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1 | |||
| hpux9 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.1 | |||
| sunos4 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.2 | |||
| solaris OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.3 | |||
| osf OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.4 | |||
| ultrix OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.5 | |||
| hpux10 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.6 | |||
| netbsd1 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.7 | |||
| freebsd OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.8 | |||
| irix OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.9 | |||
| linux OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.10 | |||
| bsdi OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.11 | |||
| openbsd OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.12 | |||
| win32 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.13 | |||
| hpux11 OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.14 | |||
| win9x OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.50 | |||
| winnt OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.51 | |||
| solspark OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.52 | |||
| solintel OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.53 | |||
| aix OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.54 | |||
| sco OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.55 | |||
| osx OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.56 | |||
| unknown OBJECT-IDENTITY | 1.3.6.1.4.1.850.2.1.255 | |||
| tlConformance OBJECT-IDENTITY | 1.3.6.1.4.1.850.20 | |||
| tlCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.1 | |||
| tlGroups OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2 | |||
| tlSubsetGroups OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2.1 | |||
| tlBasicGroups OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2.2 | |||
| tlFullGroups OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2.3 | |||
| tlUpsFullGroups OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2.3.100 | |||
| tlUpsFullAlarmGroup OBJECT-IDENTITY | 1.3.6.1.4.1.850.20.2.3.100.6 | |||
| tlPASystem OBJECT-IDENTITY | 1.3.6.1.4.1.850.90.1 | |||
| tlPAContacts OBJECT-IDENTITY | 1.3.6.1.4.1.850.90.1.1 | |||
| tlPAEmailContacts OBJECT-IDENTITY | 1.3.6.1.4.1.850.90.1.1.1 | |||
| tlPANumberOfEmailContacts OBJECT-TYPE The number email contacts currently defined. | 1.3.6.1.4.1.850.90.1.1.1.1 | NonNegativeInteger | read-only | current |
| tlPAEmailContactsTable OBJECT-TYPE A list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts. | 1.3.6.1.4.1.850.90.1.1.1.2 | not-accessible | current | |
| tlPAEmailContactEntry OBJECT-TYPE An entry containing email contacts information. | 1.3.6.1.4.1.850.90.1.1.1.2.1 | not-accessible | current | |
| tlPAEmailContactIndex OBJECT-TYPE This is the index number of the email contact. | 1.3.6.1.4.1.850.90.1.1.1.2.1.1 | PositiveInteger | read-only | current |
| tlPAEmailContactRowStatus OBJECT-TYPE The row status for the tlPAEmailContactTable row | 1.3.6.1.4.1.850.90.1.1.1.2.1.2 | RowStatus | read-write | current |
| tlPAEmailContactName OBJECT-TYPE The name of the email contact. | 1.3.6.1.4.1.850.90.1.1.1.2.1.3 | DisplayString | read-write | current |
| tlPAEmailContactAddress OBJECT-TYPE The address of the email contact. | 1.3.6.1.4.1.850.90.1.1.1.2.1.4 | DisplayString | read-write | current |
| tlPASnmpContacts OBJECT-IDENTITY | 1.3.6.1.4.1.850.90.1.1.2 | |||
| tlPANumberOfSnmpContacts OBJECT-TYPE The number SNMP contacts currently defined. | 1.3.6.1.4.1.850.90.1.1.2.1 | NonNegativeInteger | read-only | current |
| tlPASnmpContactsTable OBJECT-TYPE A list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts. | 1.3.6.1.4.1.850.90.1.1.2.2 | not-accessible | current | |
| tlPASnmpContactEntry OBJECT-TYPE An entry containing SNMP contacts information. | 1.3.6.1.4.1.850.90.1.1.2.2.1 | not-accessible | current | |
| tlPASnmpContactIndex OBJECT-TYPE This is the index number of this SNMP contact. | 1.3.6.1.4.1.850.90.1.1.2.2.1.1 | PositiveInteger | read-only | current |
| tlPASnmpContactRowStatus OBJECT-TYPE The row status for the tlPASnmpContactTable row | 1.3.6.1.4.1.850.90.1.1.2.2.1.2 | RowStatus | read-write | current |
| tlPASnmpContactName OBJECT-TYPE The name of the SNMP contact. | 1.3.6.1.4.1.850.90.1.1.2.2.1.3 | DisplayString | read-write | current |
| tlPASnmpContactIpAddress OBJECT-TYPE The IP address of the SNMP contact. | 1.3.6.1.4.1.850.90.1.1.2.2.1.4 | DisplayString | read-write | current |
| tlPASnmpContactPort OBJECT-TYPE The port of the SNMP contact. | 1.3.6.1.4.1.850.90.1.1.2.2.1.5 | PositiveInteger | read-write | current |
| tlPASnmpContactSnmpVersion OBJECT-TYPE The SNMP contact version to use for sending traps. | 1.3.6.1.4.1.850.90.1.1.2.2.1.6 | INTEGER {snmpv1(1), snmpv2c(2), snmpv3(3)} | read-write | current |
| tlPASnmpContactSecurityName OBJECT-TYPE The SNMP contact security name. | 1.3.6.1.4.1.850.90.1.1.2.2.1.7 | DisplayString | read-write | current |
| tlPASnmpContactPrivPassword OBJECT-TYPE The SNMP contact priv password to use for sending V3 traps. | 1.3.6.1.4.1.850.90.1.1.2.2.1.8 | DisplayString | read-write | current |
| tlPASnmpContactAuthPassword OBJECT-TYPE The SNMP contact auth password to use for sending V3 traps. | 1.3.6.1.4.1.850.90.1.1.2.2.1.9 | DisplayString | read-write | current |
| tlUPS OBJECT-IDENTITY | 1.3.6.1.4.1.850.100 | |||
| tlUpsObjects OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1 | |||
| tlUpsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.1 | |||
| tlUpsIdentUpsSoftwareChecksum OBJECT-TYPE A checksum for the UPS software. | 1.3.6.1.4.1.850.100.1.1.1 | Integer32 | read-only | current |
| tlUpsIdentSerialNum OBJECT-TYPE Serial number for the UPS. | 1.3.6.1.4.1.850.100.1.1.2 | DisplayString | read-only | current |
| tlUpsIdentID OBJECT-TYPE A user-supplied ID for the UPS. | 1.3.6.1.4.1.850.100.1.1.3 | Integer32 (0..65535) | read-write | current |
| tlUpsSnmpCardSerialNum OBJECT-TYPE Serial number for the UPS. | 1.3.6.1.4.1.850.100.1.1.4 | DisplayString | read-only | current |
| tlUpsSelectedDeviceID OBJECT-TYPE The device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for it | 1.3.6.1.4.1.850.100.1.1.5 | Integer32 (0..65535) | read-write | current |
| tlUpsLocation OBJECT-TYPE The device location string. | 1.3.6.1.4.1.850.100.1.1.6 | DisplayString | read-write | current |
| tlUpsBattery OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.2 | |||
| tlUpsBatteryAge OBJECT-TYPE The age of the battery in years. This is equal to the current date minus tlConfigBattReplDate. | 1.3.6.1.4.1.850.100.1.2.1 | DisplayString | read-only | current |
| tlUpsTemperatureF OBJECT-TYPE The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees. | 1.3.6.1.4.1.850.100.1.2.2 | Integer32 | read-only | current |
| tlUpsExternalBatteryAge OBJECT-TYPE The age of external battery in years. This is equal to the current date minus tlConfigExternalBattReplDate. | 1.3.6.1.4.1.850.100.1.2.3 | DisplayString | read-only | current |
| tlUpsInput OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.3 | |||
| tlUpsInputNumVoltages OBJECT-TYPE The number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table. | 1.3.6.1.4.1.850.100.1.3.1 | NonNegativeInteger | read-only | current |
| tlUpsInputVoltageTable OBJECT-TYPE A list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages. | 1.3.6.1.4.1.850.100.1.3.2 | not-accessible | current | |
| tlUpsInputVoltageEntry OBJECT-TYPE An entry containing information applicable to a particular input voltage. | 1.3.6.1.4.1.850.100.1.3.2.1 | not-accessible | current | |
| tlUpsInputVoltageIndex OBJECT-TYPE The input voltage identifier. | 1.3.6.1.4.1.850.100.1.3.2.1.1 | PositiveInteger | not-accessible | current |
| tlUpsInputVoltageType OBJECT-TYPE Whether voltage measured is phase to phase or phase to neutral. | 1.3.6.1.4.1.850.100.1.3.2.1.2 | INTEGER {phaseToNeutral(0), phaseToPhase(1)} | read-only | current |
| tlUpsInputVoltage OBJECT-TYPE The magnitude of the present input voltage. A value of 6553 indicates Unknown. | 1.3.6.1.4.1.850.100.1.3.2.1.3 | NonNegativeInteger | read-only | current |
| tlUpsInputSourceSelect OBJECT-TYPE The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(0) for devices with a single input source. Setting this value is supported only on selected models. | 1.3.6.1.4.1.850.100.1.3.3 | INTEGER {inputSourceA(0), inputSourceB(1)} | read-write | current |
| tlUpsPhaseImbalance OBJECT-TYPE Percentage of imbalance of the 3 phases. | 1.3.6.1.4.1.850.100.1.3.4 | INTEGER | read-only | current |
| tlUpsInputSourceAvailability OBJECT-TYPE The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available. | 1.3.6.1.4.1.850.100.1.3.5 | INTEGER {none(0), inputSourceA(1), inputSourceB(2), inputSourceAB(3)} | read-only | current |
| tlUpsInputSourceInUse OBJECT-TYPE The determination as to which one of two AC input lines is in use. | 1.3.6.1.4.1.850.100.1.3.6 | INTEGER {inputSourceA(0), inputSourceB(1)} | read-only | current |
| tlUpsInputSourceTransitionCount OBJECT-TYPE The number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment. | 1.3.6.1.4.1.850.100.1.3.7 | PositiveInteger | read-only | current |
| tlUpsOutput OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.4 | |||
| tlUpsOutputPowerTotal OBJECT-TYPE The power capacity of the device. | 1.3.6.1.4.1.850.100.1.4.5 | PositiveInteger | read-only | current |
| tlUpsOutputCircuits OBJECT-TYPE The number of output circuits. This variable indicates the number of rows in the output circuit table. | 1.3.6.1.4.1.850.100.1.4.6 | NonNegativeInteger | read-only | current |
| tlUpsOutputCircuitTable OBJECT-TYPE A list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits. | 1.3.6.1.4.1.850.100.1.4.7 | not-accessible | current | |
| tlUpsOutputCircuitEntry OBJECT-TYPE An entry containing information applicable to a particular output circuit. | 1.3.6.1.4.1.850.100.1.4.7.1 | not-accessible | current | |
| tlUpsOutputCircuitIndex OBJECT-TYPE The output circuit identifier. | 1.3.6.1.4.1.850.100.1.4.7.1.1 | PositiveInteger | not-accessible | current |
| tlUpsOutputCircuitStatus OBJECT-TYPE Whether the breaker is open or closed. | 1.3.6.1.4.1.850.100.1.4.7.1.2 | INTEGER {open(0), closed(1)} | read-only | current |
| tlUpsOutputCircuitLoadCurrent OBJECT-TYPE The magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown. | 1.3.6.1.4.1.850.100.1.4.7.1.3 | NonNegativeInteger | read-only | current |
| tlUpsOutputCircuitVoltage OBJECT-TYPE The magnitude of the present circuit voltage in tenths of an volt. | 1.3.6.1.4.1.850.100.1.4.7.1.4 | NonNegativeInteger | read-only | current |
| tlUpsOutputCircuitPower OBJECT-TYPE The magnitude of the present power in watts. tenths of an amp. | 1.3.6.1.4.1.850.100.1.4.7.1.5 | NonNegativeInteger | read-only | current |
| tlUpsOutputCircuitPowerFactor OBJECT-TYPE The power factor of all receptacles in a given circuit as a %. | 1.3.6.1.4.1.850.100.1.4.7.1.6 | NonNegativeInteger | read-only | current |
| tlUpsAggregatePowerFactor OBJECT-TYPE The aggregrate power factor of all phases. | 1.3.6.1.4.1.850.100.1.4.8 | PositiveInteger | read-only | current |
| tlUpsAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.6 | |||
| tlUpsAlarmsPresent OBJECT-TYPE The present number of active alarm conditions. | 1.3.6.1.4.1.850.100.1.6.1 | Gauge32 | read-only | current |
| tlUpsAlarmTable OBJECT-TYPE A list of alarm table entries. | 1.3.6.1.4.1.850.100.1.6.2 | not-accessible | current | |
| tlUpsAlarmEntry OBJECT-TYPE An entry containing information applicable to a particular alarm. | 1.3.6.1.4.1.850.100.1.6.2.1 | not-accessible | current | |
| tlUpsAlarmId OBJECT-TYPE A unique identifier for an alarm condition. | 1.3.6.1.4.1.850.100.1.6.2.1.1 | PositiveInteger | read-only | current |
| tlUpsAlarmDescr OBJECT-TYPE A description of the alarm condition. | 1.3.6.1.4.1.850.100.1.6.2.1.2 | AutonomousType | read-only | current |
| tlUpsAlarmTime OBJECT-TYPE The value of sysUpTime when the alarm condition was detected. | 1.3.6.1.4.1.850.100.1.6.2.1.3 | TimeStamp | read-only | current |
| tlUpsAlarmDetail OBJECT-TYPE A textual description of the alarm condition. | 1.3.6.1.4.1.850.100.1.6.2.1.4 | DisplayString | read-only | current |
| tlUpsAlarmDeviceId OBJECT-TYPE A numeric identifier for the device on which the alarm is active. | 1.3.6.1.4.1.850.100.1.6.2.1.5 | PositiveInteger | read-only | current |
| tlUpsAlarmDeviceName OBJECT-TYPE A string identifier for the device on which the alarm is active. | 1.3.6.1.4.1.850.100.1.6.2.1.6 | DisplayString | read-only | current |
| tlUpsAlarmLocation OBJECT-TYPE The location of the device on which the alarm is active. | 1.3.6.1.4.1.850.100.1.6.2.1.7 | DisplayString | read-only | current |
| tlUpsAlarmGroup OBJECT-TYPE The category/group of this alarm. | 1.3.6.1.4.1.850.100.1.6.2.1.8 | INTEGER {critical(1), warning(2), info(3), status(4), offline(5), custom(6)} | read-only | current |
| tlUpsAlarmIp OBJECT-TYPE The originating IP address associated with this alarm. | 1.3.6.1.4.1.850.100.1.6.2.1.9 | IpAddress | read-only | current |
| tlUpsAlarmMac OBJECT-TYPE The originating mac address associated with this alarm. | 1.3.6.1.4.1.850.100.1.6.2.1.10 | DisplayString | read-only | current |
| tlUpsWellKnownAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.6.3 | |||
| tlUpsAlarmPrimaryPowerOutage OBJECT-IDENTITY The primary power source is not present. | 1.3.6.1.4.1.850.100.1.6.3.1 | current | ||
| tlUpsAlarmSecondaryPowerOutage OBJECT-IDENTITY The secondary power source is not present. | 1.3.6.1.4.1.850.100.1.6.3.2 | current | ||
| tlUpsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY The load level is above the designated threshold. | 1.3.6.1.4.1.850.100.1.6.3.3 | current | ||
| tlUpsAlarmOutputCurrentChanged OBJECT-IDENTITY The output current changed from its last known value. | 1.3.6.1.4.1.850.100.1.6.3.4 | current | ||
| tlUpsAlarmBatteryAgeAboveThreshold OBJECT-IDENTITY One or more batteries have been determined to require replacement. | 1.3.6.1.4.1.850.100.1.6.3.5 | current | ||
| tlUpsAlarmLoadOff OBJECT-IDENTITY The load is off. | 1.3.6.1.4.1.850.100.1.6.3.6 | current | ||
| tlUpsAlarmUserDefined OBJECT-IDENTITY A user-defined event is in alarm. | 1.3.6.1.4.1.850.100.1.6.3.7 | current | ||
| tlUpsAlarmBatteryBad OBJECT-IDENTITY One or more batteries have been determined to require replacement. | 1.3.6.1.4.1.850.100.1.6.3.8 | current | ||
| tlUpsAlarmOnBattery OBJECT-IDENTITY The UPS is drawing power from the batteries. | 1.3.6.1.4.1.850.100.1.6.3.9 | current | ||
| tlUpsAlarmLowBattery OBJECT-IDENTITY The remaining battery run-time is less than or equal to upsConfigLowBattTime. | 1.3.6.1.4.1.850.100.1.6.3.10 | current | ||
| tlUpsAlarmDepletedBattery OBJECT-IDENTITY The UPS will be unable to sustain the present load when and if the utility power is lost. | 1.3.6.1.4.1.850.100.1.6.3.11 | current | ||
| tlUpsAlarmTempBad OBJECT-IDENTITY A temperature is out of tolerance. | 1.3.6.1.4.1.850.100.1.6.3.12 | current | ||
| tlUpsAlarmInputBad OBJECT-IDENTITY An input condition is out of tolerance. | 1.3.6.1.4.1.850.100.1.6.3.13 | current | ||
| tlUpsAlarmOutputBad OBJECT-IDENTITY An output condition (other than OutputOverload) is out of tolerance. | 1.3.6.1.4.1.850.100.1.6.3.14 | current | ||
| tlUpsAlarmOutputOverload OBJECT-IDENTITY The output load exceeds the UPS output capacity. | 1.3.6.1.4.1.850.100.1.6.3.15 | current | ||
| tlUpsAlarmOnBypass OBJECT-IDENTITY The Bypass is presently engaged on the UPS. | 1.3.6.1.4.1.850.100.1.6.3.16 | current | ||
| tlUpsAlarmBypassBad OBJECT-IDENTITY The Bypass is out of tolerance. | 1.3.6.1.4.1.850.100.1.6.3.17 | current | ||
| tlUpsAlarmOutputOffAsRequested OBJECT-IDENTITY The UPS has shutdown as requested, i.e., the output is off. | 1.3.6.1.4.1.850.100.1.6.3.18 | current | ||
| tlUpsAlarmUpsOffAsRequested OBJECT-IDENTITY The entire UPS has shutdown as commanded. | 1.3.6.1.4.1.850.100.1.6.3.19 | current | ||
| tlUpsAlarmChargerFailed OBJECT-IDENTITY An uncorrected problem has been detected within the UPS charger subsystem. | 1.3.6.1.4.1.850.100.1.6.3.20 | current | ||
| tlUpsAlarmUpsOutputOff OBJECT-IDENTITY The output of the UPS is in the off state. | 1.3.6.1.4.1.850.100.1.6.3.21 | current | ||
| tlUpsAlarmUpsSystemOff OBJECT-IDENTITY The UPS system is in the off state. | 1.3.6.1.4.1.850.100.1.6.3.22 | current | ||
| tlUpsAlarmFanFailure OBJECT-IDENTITY The failure of one or more fans in the UPS has been detected. | 1.3.6.1.4.1.850.100.1.6.3.23 | current | ||
| tlUpsAlarmFuseFailure OBJECT-IDENTITY The failure of one or more fuses has been detected. | 1.3.6.1.4.1.850.100.1.6.3.24 | current | ||
| tlUpsAlarmGeneralFault OBJECT-IDENTITY A general fault in the UPS has been detected. | 1.3.6.1.4.1.850.100.1.6.3.25 | current | ||
| tlUpsAlarmDiagnosticTestFailed OBJECT-IDENTITY The result of the last diagnostic test indicates a failure. | 1.3.6.1.4.1.850.100.1.6.3.26 | current | ||
| tlUpsAlarmCommunicationsLost OBJECT-IDENTITY A problem has been encountered in the communications between the agent and the UPS. | 1.3.6.1.4.1.850.100.1.6.3.27 | current | ||
| tlUpsAlarmAwaitingPower OBJECT-IDENTITY The UPS output is off and the UPS is awaiting the return of input power. | 1.3.6.1.4.1.850.100.1.6.3.28 | current | ||
| tlUpsAlarmShutdownPending OBJECT-IDENTITY A upsShutdownAfterDelay countdown is underway. | 1.3.6.1.4.1.850.100.1.6.3.29 | current | ||
| tlUpsAlarmShutdownImminent OBJECT-IDENTITY The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | 1.3.6.1.4.1.850.100.1.6.3.30 | current | ||
| tlUpsAlarmTestInProgress OBJECT-IDENTITY A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | 1.3.6.1.4.1.850.100.1.6.3.31 | current | ||
| tlUpsAlarmCircuitBreaker1Open OBJECT-IDENTITY Circuit breakers #1 is open. | 1.3.6.1.4.1.850.100.1.6.3.32 | current | ||
| tlUpsAlarmCircuitBreaker2Open OBJECT-IDENTITY Circuit breakers #2 is open. | 1.3.6.1.4.1.850.100.1.6.3.33 | current | ||
| tlUpsAlarmCircuitBreaker3Open OBJECT-IDENTITY Circuit breakers #3 is open. | 1.3.6.1.4.1.850.100.1.6.3.34 | current | ||
| tlUpsAlarmCircuitBreaker4Open OBJECT-IDENTITY Circuit breakers #4 is open. | 1.3.6.1.4.1.850.100.1.6.3.35 | current | ||
| tlUpsAlarmCircuitBreaker5Open OBJECT-IDENTITY Circuit breakers #5 is open. | 1.3.6.1.4.1.850.100.1.6.3.36 | current | ||
| tlUpsAlarmCircuitBreaker6Open OBJECT-IDENTITY Circuit breakers #6 is open. | 1.3.6.1.4.1.850.100.1.6.3.37 | current | ||
| tlUpsAlarmCircuitBreaker7Open OBJECT-IDENTITY Circuit breakers #7 is open. | 1.3.6.1.4.1.850.100.1.6.3.38 | current | ||
| tlUpsAlarmCircuitBreaker8Open OBJECT-IDENTITY Circuit breakers #8 is open. | 1.3.6.1.4.1.850.100.1.6.3.39 | current | ||
| tlUpsAlarmCurrent1AboveThreshold OBJECT-IDENTITY The output current on line 1 exceeds load limits. | 1.3.6.1.4.1.850.100.1.6.3.40 | current | ||
| tlUpsAlarmCurrent2AboveThreshold OBJECT-IDENTITY The output current on line 2 exceeds load limits. | 1.3.6.1.4.1.850.100.1.6.3.41 | current | ||
| tlUpsAlarmCurrent3AboveThreshold OBJECT-IDENTITY The output current on line 3 exceeds load limits. | 1.3.6.1.4.1.850.100.1.6.3.42 | current | ||
| tlUpsAlarmRuntimeBelowWarningLevel OBJECT-IDENTITY The battery seconds remaining is below warning level. | 1.3.6.1.4.1.850.100.1.6.3.43 | current | ||
| tlUpsAlarmBusStartVoltageLow OBJECT-IDENTITY The inverter start up bus voltage is too low. | 1.3.6.1.4.1.850.100.1.6.3.44 | current | ||
| tlUpsAlarmBusOverVoltage OBJECT-IDENTITY The inverter bus voltage is too high. | 1.3.6.1.4.1.850.100.1.6.3.45 | current | ||
| tlUpsAlarmBusUnderVoltage OBJECT-IDENTITY The inverter bus voltage is too low. | 1.3.6.1.4.1.850.100.1.6.3.46 | current | ||
| tlUpsAlarmBusVoltageUnbalanced OBJECT-IDENTITY The inverter bus voltage is not balanced. | 1.3.6.1.4.1.850.100.1.6.3.47 | current | ||
| tlUpsAlarmInverterSoftStartBad OBJECT-IDENTITY The inverter bus voltage cannot reach desired voltage within a specified duration. | 1.3.6.1.4.1.850.100.1.6.3.48 | current | ||
| tlUpsAlarmInverterOverVoltage OBJECT-IDENTITY The inverter voltage is too high. | 1.3.6.1.4.1.850.100.1.6.3.49 | current | ||
| tlUpsAlarmInverterUnderVoltage OBJECT-IDENTITY The inverter voltage is too low. | 1.3.6.1.4.1.850.100.1.6.3.50 | current | ||
| tlUpsAlarmInverterCircuitBad OBJECT-IDENTITY The inverter output is shorted. | 1.3.6.1.4.1.850.100.1.6.3.51 | current | ||
| tlUpsAlarmBatteryOverVoltage OBJECT-IDENTITY The battery voltage is too high. | 1.3.6.1.4.1.850.100.1.6.3.52 | current | ||
| tlUpsAlarmBatteryUnderVoltage OBJECT-IDENTITY The battery voltage is too low. | 1.3.6.1.4.1.850.100.1.6.3.53 | current | ||
| tlUpsAlarmSiteWiringFault OBJECT-IDENTITY The utility input wiring is faulty. | 1.3.6.1.4.1.850.100.1.6.3.54 | current | ||
| tlUpsAlarmOverTemperatureProtection OBJECT-IDENTITY The over temperature protection is activated. | 1.3.6.1.4.1.850.100.1.6.3.55 | current | ||
| tlUpsAlarmOverCharged OBJECT-IDENTITY The UPS is over charged. | 1.3.6.1.4.1.850.100.1.6.3.56 | current | ||
| tlUpsAlarmEPOActive OBJECT-IDENTITY The EPO is currently activate. | 1.3.6.1.4.1.850.100.1.6.3.57 | current | ||
| tlUpsAlarmBypassFrequencyBad OBJECT-IDENTITY The bypass frequency is out of tolerance. | 1.3.6.1.4.1.850.100.1.6.3.58 | current | ||
| tlUpsAlarmExternalSmartBatteryAgeAboveThreshold OBJECT-IDENTITY One or more external smart batteries have been determined to require replacement. | 1.3.6.1.4.1.850.100.1.6.3.59 | current | ||
| tlUpsAlarmExternalNonSmartBatteryAgeAboveThreshold OBJECT-IDENTITY One or more external non-smart batteries have been determined to require replacement. | 1.3.6.1.4.1.850.100.1.6.3.60 | current | ||
| tlUpsAlarmSmartBatteryCommLost OBJECT-IDENTITY Communications with the smart batteries was lost. | 1.3.6.1.4.1.850.100.1.6.3.61 | current | ||
| tlUpsAlarmSourceAOutage OBJECT-IDENTITY Input power source A is not present. | 1.3.6.1.4.1.850.100.1.6.3.62 | current | ||
| tlUpsAlarmSourceBOutage OBJECT-IDENTITY Input power source B is not present. | 1.3.6.1.4.1.850.100.1.6.3.63 | current | ||
| tlUpsAlarmWatchdogReset OBJECT-IDENTITY The internal watchdog triggered a reset of the device. | 1.3.6.1.4.1.850.100.1.6.3.64 | current | ||
| tlUpsAlarmDevName OBJECT-TYPE The name of the device, tlDevName, corresponding to the device that is associated with this alarm. | 1.3.6.1.4.1.850.100.1.6.7 | DisplayString | read-only | deprecated |
| tlUpsAlarmDevLocation OBJECT-TYPE The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm. | 1.3.6.1.4.1.850.100.1.6.8 | DisplayString | read-only | deprecated |
| tlUpsAlarmCategory OBJECT-TYPE The category, tlDevEvtCategory, of this alarm. | 1.3.6.1.4.1.850.100.1.6.9 | Integer32 | read-only | deprecated |
| tlUpsTest OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.7 | |||
| tlUpsTestDate OBJECT-TYPE The date of the last self-test run on the ups, in the format YYYYMMDD. | 1.3.6.1.4.1.850.100.1.7.1 | DisplayString | read-only | current |
| tlUpsTestResultsDetail OBJECT-TYPE Result of the last self-test run on the ups. | 1.3.6.1.4.1.850.100.1.7.2 | DisplayString | read-only | current |
| tlUpsControl OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.8 | |||
| tlUpsWatchdogSupported OBJECT-TYPE Indicates whether or not this UPS supports a watchdog reboot. | 1.3.6.1.4.1.850.100.1.8.1 | TruthValue | read-only | current |
| tlUpsWatchdogSecsBeforeReboot OBJECT-TYPE The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature. | 1.3.6.1.4.1.850.100.1.8.2 | NonNegativeInteger | read-write | current |
| tlUpsWellKnownControls OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.8.3 | |||
| tlUpsControlSelfTest OBJECT-TYPE Set to TRUE to initiate Self Test | 1.3.6.1.4.1.850.100.1.8.3.1 | TruthValue | read-write | current |
| tlUpsControlRamp OBJECT-TYPE Set to TRUE to initiate Ramp | 1.3.6.1.4.1.850.100.1.8.3.2 | TruthValue | read-write | current |
| tlUpsControlShed OBJECT-TYPE Set to TRUE to initiate Shed | 1.3.6.1.4.1.850.100.1.8.3.3 | TruthValue | read-write | current |
| tlUpsControlUpsOn OBJECT-TYPE Set to TRUE to turn UPS on | 1.3.6.1.4.1.850.100.1.8.3.4 | TruthValue | read-write | current |
| tlUpsControlUpsOff OBJECT-TYPE Set to TRUE to turn UPS off | 1.3.6.1.4.1.850.100.1.8.3.5 | TruthValue | read-write | current |
| tlUpsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.9 | |||
| tlUpsConfigBattReplDate OBJECT-TYPE The date on which the battery was last replaced, in the format YYYYMMDD. | 1.3.6.1.4.1.850.100.1.9.1 | DisplayString | read-write | current |
| tlUpsConfigDisplayUnits OBJECT-TYPE Selects English or Metric display for all readings. This selection may not be available on all devices. Further, some devices may support this selection, but not via a software selector. In this latter case, selections must be performed on the device itself. | 1.3.6.1.4.1.850.100.1.9.4 | INTEGER {english(0), metric(1)} | read-write | current |
| tlUpsConfigExternalBattReplDate OBJECT-TYPE The date on which the external battery was last replaced, in the format YYYYMMDD. | 1.3.6.1.4.1.850.100.1.9.5 | DisplayString | read-write | current |
| tlUpsOutlet OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.10 | |||
| tlUpsOutletNumOutlets OBJECT-TYPE The number of available Outlets in this device. | 1.3.6.1.4.1.850.100.1.10.1 | NonNegativeInteger | read-only | current |
| tlUpsOutletTable OBJECT-TYPE A list of all device Outlets for all devices. | 1.3.6.1.4.1.850.100.1.10.2 | not-accessible | current | |
| tlUpsOutletEntry OBJECT-TYPE An entry containing Outlet information applicable to a particular device managed by this agent. | 1.3.6.1.4.1.850.100.1.10.2.1 | not-accessible | current | |
| tlUpsOutletIndex OBJECT-TYPE This is the index number of this Outlet for the device indicated by tlDeviceIndex. | 1.3.6.1.4.1.850.100.1.10.2.1.1 | PositiveInteger | read-only | current |
| tlUpsOutletState OBJECT-TYPE The current state of the Outlet. | 1.3.6.1.4.1.850.100.1.10.2.1.2 | INTEGER {unknown(0), off(1), on(2)} | read-only | current |
| tlUpsOutletType OBJECT-TYPE This is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15 | 1.3.6.1.4.1.850.100.1.10.2.1.3 | Integer32 | read-only | current |
| tlUpsOutletControl OBJECT-TYPE Controls the state of the Outlet. | 1.3.6.1.4.1.850.100.1.10.2.1.4 | INTEGER {turnOff(1), turnOn(2), cycle(3)} | read-write | current |
| tlUpsOutletName OBJECT-TYPE A string identifying the devices attached to the output(s) of the device. | 1.3.6.1.4.1.850.100.1.10.2.1.5 | DisplayString | read-write | current |
| tlUpsOutletRampAction OBJECT-TYPE The ramp action to take on the Outlet. | 1.3.6.1.4.1.850.100.1.10.2.1.6 | INTEGER {remainOff(0), turnOnAfterDelay(1)} | read-write | current |
| tlUpsOutletRampDataType OBJECT-TYPE The type of data associated with ramp action. | 1.3.6.1.4.1.850.100.1.10.2.1.7 | INTEGER {delayInSeconds(0)} | read-write | current |
| tlUpsOutletRampData OBJECT-TYPE The data value associated with type of ramp data. | 1.3.6.1.4.1.850.100.1.10.2.1.8 | Integer32 | read-write | current |
| tlUpsOutletShedAction OBJECT-TYPE The shed action to take on the Outlet. | 1.3.6.1.4.1.850.100.1.10.2.1.9 | INTEGER {remainOn(0), turnOffAfterDelay(1)} | read-write | current |
| tlUpsOutletShedDataType OBJECT-TYPE The type of data associated with shed action. | 1.3.6.1.4.1.850.100.1.10.2.1.10 | INTEGER {delayInSeconds(0)} | read-write | current |
| tlUpsOutletShedData OBJECT-TYPE The data value associated with type of shed data. | 1.3.6.1.4.1.850.100.1.10.2.1.11 | Integer32 | read-write | current |
| tlUpsOutletGroupNdx OBJECT-TYPE tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped. | 1.3.6.1.4.1.850.100.1.10.2.1.12 | Integer32 | read-write | current |
| tlUpsOutletCurrent OBJECT-TYPE The value of this outlet's current, represented as 0.1A. | 1.3.6.1.4.1.850.100.1.10.2.1.13 | PositiveInteger | read-only | current |
| tlUpsOutletPower OBJECT-TYPE The value of this outlet's power in watts. | 1.3.6.1.4.1.850.100.1.10.2.1.14 | PositiveInteger | read-only | current |
| tlUpsOutletGroup OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.11 | |||
| tlUpsOutletNumOutletGroups OBJECT-TYPE The number of available Outlet Groups in this device. | 1.3.6.1.4.1.850.100.1.11.1 | NonNegativeInteger | read-only | current |
| tlUpsOutletGroupTable OBJECT-TYPE A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups. | 1.3.6.1.4.1.850.100.1.11.2 | not-accessible | current | |
| tlUpsOutletGroupEntry OBJECT-TYPE An entry containing outlet group information applicable to a particular device managed by this agent | 1.3.6.1.4.1.850.100.1.11.2.1 | not-accessible | current | |
| tlUpsOutletGroupIndex OBJECT-TYPE This is the index number of this load group for the device. | 1.3.6.1.4.1.850.100.1.11.2.1.1 | PositiveInteger | read-only | current |
| tlUpsOutletGroupRowStatus OBJECT-TYPE Row status for the tlUpsOutletGroupTable | 1.3.6.1.4.1.850.100.1.11.2.1.2 | RowStatus | read-write | current |
| tlUpsOutletGroupName OBJECT-TYPE The name of this outlet group. | 1.3.6.1.4.1.850.100.1.11.2.1.3 | DisplayString | read-write | current |
| tlUpsOutletGroupDesc OBJECT-TYPE A description for this outlet group. | 1.3.6.1.4.1.850.100.1.11.2.1.4 | DisplayString | read-write | current |
| tlUpsOutletGroupState OBJECT-TYPE The current state of the outlet group. | 1.3.6.1.4.1.850.100.1.11.2.1.5 | INTEGER {unknown(0), off(1), on(2), mixed(3)} | read-only | current |
| tlUpsOutletGroupControl OBJECT-TYPE Controls the state of every outlet associated with the group. | 1.3.6.1.4.1.850.100.1.11.2.1.6 | INTEGER {turnOff(1), turnOn(2), cycle(3)} | read-write | current |
| tlUpsMainOutlet OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.12 | |||
| tlUpsMainOutletState OBJECT-TYPE The current state of the main output of the device. | 1.3.6.1.4.1.850.100.1.12.1 | INTEGER {unknown(0), off(1), on(2), mixed(3)} | read-only | current |
| tlUpsMainOutletControllable OBJECT-TYPE Indicates if this device has controllable outlets | 1.3.6.1.4.1.850.100.1.12.2 | TruthValue | read-only | current |
| tlUpsMainOutletControl OBJECT-TYPE Controls the state of the main outlet of the device. | 1.3.6.1.4.1.850.100.1.12.3 | INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)} | read-write | current |
| tlUpsEnvironment OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.1.13 | |||
| tlUpsTemperature OBJECT-TYPE The ambient temperature. The measurement returned will either be in units of Celsius (C) or Fahrenheit (F) depending upon whether Metric or English was selected for the reading by tlUpsConfigDisplayUnits. | 1.3.6.1.4.1.850.100.1.13.1 | Integer32 | read-only | current |
| tlUpsTraps OBJECT-IDENTITY | 1.3.6.1.4.1.850.100.2 | |||
| tlEnviroSense OBJECT-IDENTITY | 1.3.6.1.4.1.850.101 | |||
| tlEnvEnvironment OBJECT-IDENTITY | 1.3.6.1.4.1.850.101.1 | |||
| tlEnvTemperatureData OBJECT-IDENTITY | 1.3.6.1.4.1.850.101.1.1 | |||
| tlEnvTemperatureC OBJECT-TYPE The ambient temperature (C). | 1.3.6.1.4.1.850.101.1.1.1 | Integer32 | read-only | current |
| tlEnvTemperatureF OBJECT-TYPE The ambient temperature (F). | 1.3.6.1.4.1.850.101.1.1.2 | Integer32 | read-only | current |
| tlEnvTemperatureLowLimit OBJECT-TYPE The lower alarm limit for ambient temperature (F). | 1.3.6.1.4.1.850.101.1.1.3 | Integer32 | read-write | current |
| tlEnvTemperatureHighLimit OBJECT-TYPE The upper alarm limit for ambient temperature (F). | 1.3.6.1.4.1.850.101.1.1.4 | Integer32 | read-write | current |
| tlEnvTemperatureInAlarm OBJECT-TYPE Indicates whether or not temperature is in alarm. | 1.3.6.1.4.1.850.101.1.1.5 | TruthValue | read-only | current |
| tlEnvHumidityData OBJECT-IDENTITY | 1.3.6.1.4.1.850.101.1.2 | |||
| tlEnvHumidity OBJECT-TYPE The ambient humidity (%). | 1.3.6.1.4.1.850.101.1.2.1 | Integer32 | read-only | current |
| tlEnvHumidityLowLimit OBJECT-TYPE The lower alarm limit for ambient humidity (%). | 1.3.6.1.4.1.850.101.1.2.2 | Integer32 | read-write | current |
| tlEnvHumidityHighLimit OBJECT-TYPE The upper alarm limit for ambient humidity (%). | 1.3.6.1.4.1.850.101.1.2.3 | Integer32 | read-write | current |
| tlEnvHumidityInAlarm OBJECT-TYPE Indicates whether or not humidity is in alarm. | 1.3.6.1.4.1.850.101.1.2.4 | TruthValue | read-only | current |
| tlEnvContacts OBJECT-IDENTITY | 1.3.6.1.4.1.850.101.2 | |||
| tlEnvContactTable OBJECT-TYPE A table of contacts. | 1.3.6.1.4.1.850.101.2.1 | not-accessible | current | |
| tlEnvContactEntry OBJECT-TYPE An entry containing information applicable to a particular contact. | 1.3.6.1.4.1.850.101.2.1.1 | not-accessible | current | |
| tlEnvContactIndex OBJECT-TYPE The table row index for the contact. | 1.3.6.1.4.1.850.101.2.1.1.1 | PositiveInteger | read-only | current |
| tlEnvContactName OBJECT-TYPE The name or description of the contact. | 1.3.6.1.4.1.850.101.2.1.1.2 | DisplayString | read-write | current |
| tlEnvContactStatus OBJECT-TYPE The current status of the contact. | 1.3.6.1.4.1.850.101.2.1.1.3 | INTEGER {normal(0), alarm(1)} | read-only | current |
| tlEnvContactConfig OBJECT-TYPE The configuration of the contact. | 1.3.6.1.4.1.850.101.2.1.1.4 | INTEGER {normallyOpen(0), normallyClosed(1)} | read-write | current |
| tlCooling OBJECT-IDENTITY | 1.3.6.1.4.1.850.103 | |||
| tlCoolingEnvironment OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1 | |||
| tlCoolingIdent OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1.1 | |||
| tlCoolingModel OBJECT-TYPE The model name for the AC Unit. | 1.3.6.1.4.1.850.103.1.1.1 | DisplayString | read-only | current |
| tlCoolingManufacturer OBJECT-TYPE The manufacturer of the AC Unit. | 1.3.6.1.4.1.850.103.1.1.2 | DisplayString | read-only | current |
| tlCoolingSerialNumber OBJECT-TYPE The serial number of the AC unit. | 1.3.6.1.4.1.850.103.1.1.3 | DisplayString | read-only | current |
| tlCoolingFirmwareVersion OBJECT-TYPE The firmware version of the AC Unit. | 1.3.6.1.4.1.850.103.1.1.4 | DisplayString | read-only | current |
| tlCoolingHostSoftwareVersion OBJECT-TYPE The hardware version of the AC unit. | 1.3.6.1.4.1.850.103.1.1.5 | DisplayString | read-only | current |
| tlCoolingName OBJECT-TYPE The user defined name for the AC Unit. | 1.3.6.1.4.1.850.103.1.1.6 | DisplayString | read-write | current |
| tlCoolingLocation OBJECT-TYPE The user defined location of the AC Unit. | 1.3.6.1.4.1.850.103.1.1.7 | DisplayString | read-write | current |
| tlCoolingStatus OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1.2 | |||
| tlCoolingCondOutletTemp OBJECT-TYPE The condenser outlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.1 | INTEGER | read-only | current |
| tlCoolingCondInletTemp OBJECT-TYPE The condenser inlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.2 | INTEGER | read-only | current |
| tlCoolingRefrigerantTemp OBJECT-TYPE The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.3 | INTEGER | read-only | current |
| tlCoolingEvapSurfaceTemp OBJECT-TYPE The surface temperature of the evaporator in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.4 | INTEGER | read-only | current |
| tlCoolingSuctionPressure OBJECT-TYPE The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.5 | INTEGER | read-only | current |
| tlCoolingDischargePressure OBJECT-TYPE The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.6 | INTEGER | read-only | current |
| tlCoolingEvapFanSpeed OBJECT-TYPE The current speed of the evaporator fan. | 1.3.6.1.4.1.850.103.1.2.7 | INTEGER {off(0), low(1), medLow(2), med(3), medHi(4), hi(5)} | read-only | current |
| tlCoolingCondFanSpeed OBJECT-TYPE The current speed of the condenser fan. | 1.3.6.1.4.1.850.103.1.2.8 | INTEGER {off(0), low(1), hi(2)} | read-only | current |
| tlCoolingCompFrequency OBJECT-TYPE The operating frequency of the compressor in tenths of Arms. | 1.3.6.1.4.1.850.103.1.2.9 | INTEGER | read-only | current |
| tlCoolingEEVPercentage OBJECT-TYPE The opening percentage of the EEV. | 1.3.6.1.4.1.850.103.1.2.10 | INTEGER | read-only | current |
| tlCoolingUnitCurrent OBJECT-TYPE The the total current draw of the unit in tenths of Arms. | 1.3.6.1.4.1.850.103.1.2.11 | INTEGER | read-only | current |
| tlCoolingFanCurrent OBJECT-TYPE Thethe current draw of the Evaporator and Condenser fans in tents of Arms. | 1.3.6.1.4.1.850.103.1.2.12 | INTEGER | read-only | current |
| tlCoolingCompCurrent OBJECT-TYPE The operating current of the compressor in Arms. | 1.3.6.1.4.1.850.103.1.2.13 | INTEGER | read-only | current |
| tlCoolingReturnAirTemp OBJECT-TYPE The return air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.14 | INTEGER | read-only | current |
| tlCoolingSuctionTemp OBJECT-TYPE The temperature of the compressor suction line in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.15 | INTEGER | read-only | current |
| tlCoolingSupplyAirTemp OBJECT-TYPE The supply air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits. | 1.3.6.1.4.1.850.103.1.2.16 | INTEGER | read-only | current |
| tlCoolingRunTimes OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1.3 | |||
| tlCoolingAirFilterRunHours OBJECT-TYPE Total hours the air filter has been under operation. | 1.3.6.1.4.1.850.103.1.3.1 | Integer32 | read-only | current |
| tlCoolingEvapFanRunDays OBJECT-TYPE Total days the evaporator fan has been under operation. | 1.3.6.1.4.1.850.103.1.3.2 | Integer32 | read-only | current |
| tlCoolingCondFanRunDays OBJECT-TYPE Total days the condenser fan has been under operation. | 1.3.6.1.4.1.850.103.1.3.3 | Integer32 | read-only | current |
| tlCoolingCompressorRunDays OBJECT-TYPE Total days the compressor has been under operation. | 1.3.6.1.4.1.850.103.1.3.4 | Integer32 | read-only | current |
| tlCoolingCondPumpRunDays OBJECT-TYPE Total days the condensate pump has been under operation. | 1.3.6.1.4.1.850.103.1.3.5 | Integer32 | read-only | current |
| tlCoolingAtomizerRunDays OBJECT-TYPE Total days the atomizer has been under operation. | 1.3.6.1.4.1.850.103.1.3.6 | Integer32 | read-only | current |
| tlCoolingConfig OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1.4 | |||
| tlCoolingOnOff OBJECT-TYPE Turn the unit off or on. | 1.3.6.1.4.1.850.103.1.4.1 | INTEGER {turnOffUnit(0), turnOnUnit(1)} | read-write | current |
| tlCoolingSetPointTemp OBJECT-TYPE The set point temperature the unit will control the temperature to in tenths of degrees in Celsius or Fahrenheit based upon tleCoolDisplayUnits. | 1.3.6.1.4.1.850.103.1.4.2 | INTEGER | read-write | current |
| tlCoolingAutoStart OBJECT-TYPE Specified if the unit should start automatically on power up. | 1.3.6.1.4.1.850.103.1.4.3 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| tlCoolingFanSpeedOverride OBJECT-TYPE Speed of evaporator fan set by the user. | 1.3.6.1.4.1.850.103.1.4.4 | INTEGER {autoFanSpeed(0), low(1), medLow(2), med(3), medHi(4), hi(5)} | read-write | current |
| tlCoolingControlType OBJECT-TYPE Which temperature to be used as a control point. | 1.3.6.1.4.1.850.103.1.4.5 | INTEGER {returnAirTemp(0), remoteTemperature(1)} | read-write | current |
| tlCoolingCurrentRemoteTemp OBJECT-TYPE The external remote temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlCoolingDisplayUnits | 1.3.6.1.4.1.850.103.1.4.6 | INTEGER | read-write | current |
| tlCoolingDisplayUnits OBJECT-TYPE Selects English or Metric display for all readings. | 1.3.6.1.4.1.850.103.1.4.7 | INTEGER {metric(0), english(1)} | read-write | current |
| tlCoolingBeepOnKey OBJECT-TYPE Indicates if the display sounds a beep when a key is pressed. | 1.3.6.1.4.1.850.103.1.4.8 | INTEGER {noBeep(0), beepOn(1)} | read-write | current |
| tlCoolingOutputRelaySource OBJECT-TYPE The alarm level that causes the ouput relay to activate. | 1.3.6.1.4.1.850.103.1.4.9 | INTEGER {disabled(0), allAlarmsAndWarnings(1), criticalAlarmsOnly(2)} | read-write | current |
| tlCoolingOffOnLeak OBJECT-TYPE Indicates if the unit should stop cooling when leak input is activated. | 1.3.6.1.4.1.850.103.1.4.10 | INTEGER {turnOff(0), alarmOnly(1)} | read-write | current |
| tlCoolingOffOnInputContact OBJECT-TYPE Indicates if the unit should stop cooling when input contact is activated. | 1.3.6.1.4.1.850.103.1.4.11 | INTEGER {turnOff(0), alarmOnly(1)} | read-write | current |
| tlCoolingInputContactType OBJECT-TYPE The input contact type. | 1.3.6.1.4.1.850.103.1.4.12 | INTEGER {ncRelay(0), noRelay(1)} | read-write | current |
| tlCoolingOutputRelayDefault OBJECT-TYPE Type of contact to make when output relay is activated. | 1.3.6.1.4.1.850.103.1.4.13 | INTEGER {nc(0), no(1)} | read-write | current |
| tlCoolingAirFilterInterval OBJECT-TYPE The number of weeks before the air filter needs to be changed. | 1.3.6.1.4.1.850.103.1.4.14 | Integer32 | read-write | current |
| tlCoolingWaterLeakContactType OBJECT-TYPE The input contact type. | 1.3.6.1.4.1.850.103.1.4.15 | INTEGER {noRelay(0), ncRelay(1)} | read-write | current |
| tlCoolingThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.1.5 | |||
| tlCoolingMaxAirFilterRunHours OBJECT-TYPE The maximum interval for air filter run hours before warning is annunciated. | 1.3.6.1.4.1.850.103.1.5.1 | Integer32 | read-write | current |
| tlCoolingEnableAirFilterAlarm OBJECT-TYPE When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded. | 1.3.6.1.4.1.850.103.1.5.2 | INTEGER {disabled(0), enabled(1)} | read-write | current |
| tlCoolingMaxSupplyTemp OBJECT-TYPE Maximum allowed supply air temperature before firing an alarm. | 1.3.6.1.4.1.850.103.1.5.3 | INTEGER | read-write | current |
| tlCoolingMinSupplyTemp OBJECT-TYPE Minimum allowed supply air temperature allowed before firing an alarm. | 1.3.6.1.4.1.850.103.1.5.4 | INTEGER | read-write | current |
| tlCoolingTempDiffAlarm OBJECT-TYPE Maximum allowed air temperature deviation from set allowed before firing an alarm. | 1.3.6.1.4.1.850.103.1.5.5 | INTEGER | read-write | current |
| tlCoolingMaxReturnAirTemp OBJECT-TYPE When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded. | 1.3.6.1.4.1.850.103.1.5.6 | INTEGER | read-write | current |
| tlCoolingAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.6 | |||
| tlCoolingWellKnownAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.850.103.6.3 | |||
| tlCoolingSupplyAirSensorFault OBJECT-IDENTITY The supply air sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.1 | current | ||
| tlCoolingReturnAirSensorFault OBJECT-IDENTITY The return air sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.2 | current | ||
| tlCoolingCondenserInletAirSensorFault OBJECT-IDENTITY The condenser inlet air sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.3 | current | ||
| tlCoolingCondenserOutletAirSensorFault OBJECT-IDENTITY The condenser outlet air sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.4 | current | ||
| tlCoolingSuctionTemperatureSensorFault OBJECT-IDENTITY The suction temperature sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.5 | current | ||
| tlCoolingEvaporatorTemperatureSensorFault OBJECT-IDENTITY The evaporator temperature sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.6 | current | ||
| tlCoolingAirFilterClogged OBJECT-IDENTITY The air filter is clogged. | 1.3.6.1.4.1.850.103.6.3.7 | current | ||
| tlCoolingAirFilterRunHoursViolation OBJECT-IDENTITY The air filter run hours was violated. | 1.3.6.1.4.1.850.103.6.3.8 | current | ||
| tlCoolingSuctionPressureSensorFault OBJECT-IDENTITY The suction pressure sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.9 | current | ||
| tlCoolingInverterCommunicationsFault OBJECT-IDENTITY The inverter communications is in fault. | 1.3.6.1.4.1.850.103.6.3.10 | current | ||
| tlCoolingRemoteShutdownViaInputContact OBJECT-IDENTITY A remote shutdown was triggerd by an input contact. | 1.3.6.1.4.1.850.103.6.3.11 | current | ||
| tlCoolingCondensatePumpFault OBJECT-IDENTITY The condensate pump is in fault. | 1.3.6.1.4.1.850.103.6.3.12 | current | ||
| tlCoolingLowRefrigerantStartupFault OBJECT-IDENTITY The low refrigerant startup is in fault. | 1.3.6.1.4.1.850.103.6.3.13 | current | ||
| tlCoolingCondenserFanFault OBJECT-IDENTITY The condenser fan is in fault. | 1.3.6.1.4.1.850.103.6.3.14 | current | ||
| tlCoolingCondenserFailure OBJECT-IDENTITY The condenser has failed. | 1.3.6.1.4.1.850.103.6.3.15 | current | ||
| tlCoolingEvaporatorCoolingFailure OBJECT-IDENTITY The evaporator cooling is in fault. | 1.3.6.1.4.1.850.103.6.3.16 | current | ||
| tlCoolingReturnAirTempHigh OBJECT-IDENTITY The return air temperature is high. | 1.3.6.1.4.1.850.103.6.3.17 | current | ||
| tlCoolingSupplyAirTempHigh OBJECT-IDENTITY The supply air temperature is high. | 1.3.6.1.4.1.850.103.6.3.18 | current | ||
| tlCoolingEvaporatorFailure OBJECT-IDENTITY The evaporator has failed. | 1.3.6.1.4.1.850.103.6.3.19 | current | ||
| tlCoolingEvaporatorFreezeUp OBJECT-IDENTITY The evaporator is frozen. | 1.3.6.1.4.1.850.103.6.3.20 | current | ||
| tlCoolingDischargePressureHigh OBJECT-IDENTITY The discharge pressure is high. | 1.3.6.1.4.1.850.103.6.3.21 | current | ||
| tlCoolingPressureGaugeFailure OBJECT-IDENTITY The pressure gauge has failed. | 1.3.6.1.4.1.850.103.6.3.22 | current | ||
| tlCoolingDischargePressurePersistentHigh OBJECT-IDENTITY The discharge pressure is persistently high. | 1.3.6.1.4.1.850.103.6.3.23 | current | ||
| tlCoolingSuctionPressureLowStartFailure OBJECT-IDENTITY Cannot start due to low suction pressure. | 1.3.6.1.4.1.850.103.6.3.24 | current | ||
| tlCoolingSuctionPressureLow OBJECT-IDENTITY The suction pressure is low. | 1.3.6.1.4.1.850.103.6.3.25 | current | ||
| tlCoolingSuctionPressurePersistentLow OBJECT-IDENTITY The suction pressure is persistently low. | 1.3.6.1.4.1.850.103.6.3.26 | current | ||
| tlCoolingStartupLinePressureImbalance OBJECT-IDENTITY The startup line pressure is in imbalance. | 1.3.6.1.4.1.850.103.6.3.27 | current | ||
| tlCoolingCompressorFailure OBJECT-IDENTITY The compressor has failed. | 1.3.6.1.4.1.850.103.6.3.28 | current | ||
| tlCoolingCurrentLimit OBJECT-IDENTITY The current is out of range. | 1.3.6.1.4.1.850.103.6.3.29 | current | ||
| tlCoolingWaterLeak OBJECT-IDENTITY Water is leaking. | 1.3.6.1.4.1.850.103.6.3.30 | current | ||
| tlCoolingFanUnderCurrent OBJECT-IDENTITY The fan is under current. | 1.3.6.1.4.1.850.103.6.3.31 | current | ||
| tlCoolingFanOverCurrent OBJECT-IDENTITY The fan is over current. | 1.3.6.1.4.1.850.103.6.3.32 | current | ||
| tlCoolingDischargePressureSensorFault OBJECT-IDENTITY The discharge pressure sensor is in fault. | 1.3.6.1.4.1.850.103.6.3.33 | current | ||
| tlCoolingWaterFull OBJECT-IDENTITY Water is Full. | 1.3.6.1.4.1.850.103.6.3.34 | current | ||
| tlCoolingAutoCoolingOn OBJECT-IDENTITY Automatic cooling was activated to lower the temperature below the remote set point. | 1.3.6.1.4.1.850.103.6.3.35 | current | ||
| tlCoolingPowerButtonPressed OBJECT-IDENTITY Power button was pressed on the front panel. | 1.3.6.1.4.1.850.103.6.3.36 | current | ||
| tlCoolingDisconnectedFromDevice OBJECT-IDENTITY The device communications is disconnected. | 1.3.6.1.4.1.850.103.6.3.37 | current | ||
| tlSrCoolNet OBJECT-IDENTITY | 1.3.6.1.4.1.850.104 | |||
| tlSrCoolNetData OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.1 | |||
| tlSrCoolNetIdent OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.1.1 | |||
| tlSrCoolNetModel OBJECT-TYPE The model name for the device attached to the SRCOOLNET. | 1.3.6.1.4.1.850.104.1.1.1 | DisplayString | read-only | current |
| tlSrCoolNetManufacturer OBJECT-TYPE The manufacturer of the AC Unit. | 1.3.6.1.4.1.850.104.1.1.2 | DisplayString | read-only | current |
| tlSrCoolNetSerialNumber OBJECT-TYPE The serial number of the SRCOOLNET device. | 1.3.6.1.4.1.850.104.1.1.3 | DisplayString | read-only | current |
| tlSrCoolNetHostSoftwareVersion OBJECT-TYPE The software version of the SRCOOLNET device. | 1.3.6.1.4.1.850.104.1.1.4 | DisplayString | read-only | current |
| tlSrCoolNetName OBJECT-TYPE The user defined name for the AC Unit. | 1.3.6.1.4.1.850.104.1.1.5 | DisplayString | read-write | current |
| tlSrCoolNetLocation OBJECT-TYPE The user defined location of the AC Unit. | 1.3.6.1.4.1.850.104.1.1.6 | DisplayString | read-write | current |
| tlSrCoolNetStatus OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.1.2 | |||
| tlSrCoolNetMode OBJECT-TYPE The current mode of SRCOOLNET. | 1.3.6.1.4.1.850.104.1.2.1 | INTEGER {off(0), idle(1), cooling(2), unknown(3), dehumidifying(4), defrost(5), notconnected(6)} | read-only | current |
| tlSrCoolNetFanSpeed OBJECT-TYPE The current speed of the fan. | 1.3.6.1.4.1.850.104.1.2.2 | INTEGER {off(0), low(1), med(2), hi(3)} | read-only | current |
| tlSrCoolNetReturnAirTemp OBJECT-TYPE The return air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlSrCoolNetDisplayUnits. | 1.3.6.1.4.1.850.104.1.2.3 | INTEGER | read-only | current |
| tlSrCoolNetWaterFull OBJECT-TYPE Indicates the water reservoir is full or not full. | 1.3.6.1.4.1.850.104.1.2.4 | INTEGER {waterNotFull(0), waterFull(1)} | read-only | current |
| tlSrCoolNetCurrentRemoteTemp OBJECT-TYPE The EnviroSense temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlSrCoolNetDisplayUnits. Only available if EnviroSense is connected to SRCOOLNET. | 1.3.6.1.4.1.850.104.1.2.5 | INTEGER | read-only | current |
| tlSrCoolNetDisplayUnits OBJECT-TYPE Selects English or Metric display for all readings. AC unit must be manually configured to match this setting. | 1.3.6.1.4.1.850.104.1.2.6 | INTEGER {metric(0), english(1)} | read-only | current |
| tlSrCoolNetConfig OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.1.3 | |||
| tlSrCoolNetOnOff OBJECT-TYPE Turn the unit off or on. | 1.3.6.1.4.1.850.104.1.3.1 | INTEGER {turnOffUnit(0), turnOnUnit(1)} | read-write | current |
| tlSrCoolSetMode OBJECT-TYPE Set the operating mode of cooling unit. Unit must be ON to set mode. | 1.3.6.1.4.1.850.104.1.3.2 | INTEGER {cooling(0), dehumidifying(1)} | read-write | current |
| tlSrCoolNetSetPointTemp OBJECT-TYPE The local set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits. | 1.3.6.1.4.1.850.104.1.3.3 | INTEGER | read-write | current |
| tlSrCoolNetRemoteSetPointTemp OBJECT-TYPE The remote set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits. Only available when EnviroSense is connected to SRCOOLNET. | 1.3.6.1.4.1.850.104.1.3.4 | INTEGER | read-write | current |
| tlSrCoolNetFanSpeedSetting OBJECT-TYPE Set the fan speed of the AC unit. | 1.3.6.1.4.1.850.104.1.3.5 | INTEGER {auto(0), low(1), med(2), high(3)} | read-write | current |
| tlSrCoolNetRemoteSetpointEnable OBJECT-TYPE Use remote temperature setpoint for control point versus return air temp. Only available when EnviroSense is connected to SRCOOLNET. | 1.3.6.1.4.1.850.104.1.3.6 | INTEGER {disable(0), enable(1)} | read-write | current |
| tlSrCoolNetFanAlwaysOn OBJECT-TYPE Leave fans on when not cooling. Only available when EnviroSense is connected to SRCOOLNET. | 1.3.6.1.4.1.850.104.1.3.7 | INTEGER {disable(0), enable(1)} | read-write | current |
| tlSrCoolNetAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.2 | |||
| tlSrCoolNetWellKnownAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.850.104.2.1 | |||
| tlSrCoolNetWaterFullAlarm OBJECT-IDENTITY Water reservoir full. | 1.3.6.1.4.1.850.104.2.1.1 | current |
Notifications
| Name | OID | Status |
|---|---|---|
| tlUpsTrapAlarmEntryAddedV1 NOTIFICATION-TYPE This trap is sent each time an alarm is inserted into to the alarm table. | 1.3.6.1.4.1.850.100.2.0.3 | |
| tlUpsTrapAlarmEntryRemovedV1 NOTIFICATION-TYPE This trap is sent each time an alarm is removed from the alarm table. | 1.3.6.1.4.1.850.100.2.0.4 | |
| tlUpsTrapAlarmEntryAdded NOTIFICATION-TYPE This trap is sent each time an alarm is inserted into to the alarm table. | 1.3.6.1.4.1.850.100.2.3 | current |
| tlUpsTrapAlarmEntryRemoved NOTIFICATION-TYPE This trap is sent each time an alarm is removed from the alarm table. | 1.3.6.1.4.1.850.100.2.4 | current |
| tlUpsTrapSystemStartup NOTIFICATION-TYPE Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) | 1.3.6.1.4.1.850.100.2.5 | current |
| tlUpsTrapSystemShutdown NOTIFICATION-TYPE Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) | 1.3.6.1.4.1.850.100.2.6 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| tlUpsFullIdentGroup OBJECT-GROUP The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.1 | current |
| tlUpsFullBatteryGroup OBJECT-GROUP The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.2 | current |
| tlUpsFullAlarmObjsGroup OBJECT-GROUP The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.6.1 | current |
| tlUpsFullTestGroup OBJECT-GROUP The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.7 | current |
| tlUpsFullControlGroup OBJECT-GROUP The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.8 | current |
| tlUpsFullConfigGroup OBJECT-GROUP The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.9 | current |
| tlUpsFullOutletGroup OBJECT-GROUP The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's | 1.3.6.1.4.1.850.20.2.3.100.10 | current |