MIBs Depot

TRIPPLITE-12X

Registered at
1.3.6.1.4.1.850.2
1.3.6.1.4.1.850.20
1.3.6.1.4.1.850.90
1.3.6.1.4.1.850.100
1.3.6.1.4.1.850.101
1.3.6.1.4.1.850.103
1.3.6.1.4.1.850.104
Last updated
2017-02-28 16:00
Organization
Tripp Lite
Revisions
2017-02-28 16:00, 2015-07-29 00:00, 2014-10-17 09:30, 2014-09-18 10:00, 2014-08-06 08:30, 2014-05-08 08:30, 2014-04-09 10:00, 2013-10-30 13:00
Namespace
poweralert
Source file
TRIPPLITE-12X
Digest
sha256:b808128dd3e62efd14028fc7d6aace4441d49d4fd138a65cdf7ab04f4c939b80

Description

This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.

Contact

Software Engineering Tripp Lite 1111 W. 35th St. Chicago, IL 60609

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso
SNMPv2-TCAutonomousType, DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeInterval, TimeStamp, TruthValue, VariablePointer
TRIPPLITEtripplite
UPS-MIBNonNegativeInteger, PositiveInteger

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
TRIPPLITE
TRIPPLITE-12X
UPS-MIB

Objects

NameOIDSyntaxAccessStatus
tlEnumerations
OBJECT-IDENTITY
1.3.6.1.4.1.850.2
tlOperatingSystems
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1
hpux9
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.1
sunos4
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.2
solaris
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.3
osf
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.4
ultrix
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.5
hpux10
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.6
netbsd1
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.7
freebsd
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.8
irix
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.9
linux
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.10
bsdi
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.11
openbsd
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.12
win32
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.13
hpux11
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.14
win9x
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.50
winnt
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.51
solspark
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.52
solintel
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.53
aix
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.54
sco
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.55
osx
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.56
unknown
OBJECT-IDENTITY
1.3.6.1.4.1.850.2.1.255
tlConformance
OBJECT-IDENTITY
1.3.6.1.4.1.850.20
tlCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.1
tlGroups
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2
tlSubsetGroups
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2.1
tlBasicGroups
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2.2
tlFullGroups
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2.3
tlUpsFullGroups
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2.3.100
tlUpsFullAlarmGroup
OBJECT-IDENTITY
1.3.6.1.4.1.850.20.2.3.100.6
tlPASystem
OBJECT-IDENTITY
1.3.6.1.4.1.850.90.1
tlPAContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.90.1.1
tlPAEmailContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.90.1.1.1
tlPANumberOfEmailContacts
OBJECT-TYPE
The number email contacts currently defined.
1.3.6.1.4.1.850.90.1.1.1.1NonNegativeIntegerread-onlycurrent
tlPAEmailContactsTable
OBJECT-TYPE
A list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts.
1.3.6.1.4.1.850.90.1.1.1.2not-accessiblecurrent
tlPAEmailContactEntry
OBJECT-TYPE
An entry containing email contacts information.
1.3.6.1.4.1.850.90.1.1.1.2.1not-accessiblecurrent
tlPAEmailContactIndex
OBJECT-TYPE
This is the index number of the email contact.
1.3.6.1.4.1.850.90.1.1.1.2.1.1PositiveIntegerread-onlycurrent
tlPAEmailContactRowStatus
OBJECT-TYPE
The row status for the tlPAEmailContactTable row
1.3.6.1.4.1.850.90.1.1.1.2.1.2RowStatusread-writecurrent
tlPAEmailContactName
OBJECT-TYPE
The name of the email contact.
1.3.6.1.4.1.850.90.1.1.1.2.1.3DisplayStringread-writecurrent
tlPAEmailContactAddress
OBJECT-TYPE
The address of the email contact.
1.3.6.1.4.1.850.90.1.1.1.2.1.4DisplayStringread-writecurrent
tlPASnmpContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.90.1.1.2
tlPANumberOfSnmpContacts
OBJECT-TYPE
The number SNMP contacts currently defined.
1.3.6.1.4.1.850.90.1.1.2.1NonNegativeIntegerread-onlycurrent
tlPASnmpContactsTable
OBJECT-TYPE
A list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts.
1.3.6.1.4.1.850.90.1.1.2.2not-accessiblecurrent
tlPASnmpContactEntry
OBJECT-TYPE
An entry containing SNMP contacts information.
1.3.6.1.4.1.850.90.1.1.2.2.1not-accessiblecurrent
tlPASnmpContactIndex
OBJECT-TYPE
This is the index number of this SNMP contact.
1.3.6.1.4.1.850.90.1.1.2.2.1.1PositiveIntegerread-onlycurrent
tlPASnmpContactRowStatus
OBJECT-TYPE
The row status for the tlPASnmpContactTable row
1.3.6.1.4.1.850.90.1.1.2.2.1.2RowStatusread-writecurrent
tlPASnmpContactName
OBJECT-TYPE
The name of the SNMP contact.
1.3.6.1.4.1.850.90.1.1.2.2.1.3DisplayStringread-writecurrent
tlPASnmpContactIpAddress
OBJECT-TYPE
The IP address of the SNMP contact.
1.3.6.1.4.1.850.90.1.1.2.2.1.4DisplayStringread-writecurrent
tlPASnmpContactPort
OBJECT-TYPE
The port of the SNMP contact.
1.3.6.1.4.1.850.90.1.1.2.2.1.5PositiveIntegerread-writecurrent
tlPASnmpContactSnmpVersion
OBJECT-TYPE
The SNMP contact version to use for sending traps.
1.3.6.1.4.1.850.90.1.1.2.2.1.6INTEGER {snmpv1(1), snmpv2c(2), snmpv3(3)}read-writecurrent
tlPASnmpContactSecurityName
OBJECT-TYPE
The SNMP contact security name.
1.3.6.1.4.1.850.90.1.1.2.2.1.7DisplayStringread-writecurrent
tlPASnmpContactPrivPassword
OBJECT-TYPE
The SNMP contact priv password to use for sending V3 traps.
1.3.6.1.4.1.850.90.1.1.2.2.1.8DisplayStringread-writecurrent
tlPASnmpContactAuthPassword
OBJECT-TYPE
The SNMP contact auth password to use for sending V3 traps.
1.3.6.1.4.1.850.90.1.1.2.2.1.9DisplayStringread-writecurrent
tlUPS
OBJECT-IDENTITY
1.3.6.1.4.1.850.100
tlUpsObjects
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1
tlUpsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.1
tlUpsIdentUpsSoftwareChecksum
OBJECT-TYPE
A checksum for the UPS software.
1.3.6.1.4.1.850.100.1.1.1Integer32read-onlycurrent
tlUpsIdentSerialNum
OBJECT-TYPE
Serial number for the UPS.
1.3.6.1.4.1.850.100.1.1.2DisplayStringread-onlycurrent
tlUpsIdentID
OBJECT-TYPE
A user-supplied ID for the UPS.
1.3.6.1.4.1.850.100.1.1.3Integer32 (0..65535)read-writecurrent
tlUpsSnmpCardSerialNum
OBJECT-TYPE
Serial number for the UPS.
1.3.6.1.4.1.850.100.1.1.4DisplayStringread-onlycurrent
tlUpsSelectedDeviceID
OBJECT-TYPE
The device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for it
1.3.6.1.4.1.850.100.1.1.5Integer32 (0..65535)read-writecurrent
tlUpsLocation
OBJECT-TYPE
The device location string.
1.3.6.1.4.1.850.100.1.1.6DisplayStringread-writecurrent
tlUpsBattery
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.2
tlUpsBatteryAge
OBJECT-TYPE
The age of the battery in years. This is equal to the current date minus tlConfigBattReplDate.
1.3.6.1.4.1.850.100.1.2.1DisplayStringread-onlycurrent
tlUpsTemperatureF
OBJECT-TYPE
The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees.
1.3.6.1.4.1.850.100.1.2.2Integer32read-onlycurrent
tlUpsExternalBatteryAge
OBJECT-TYPE
The age of external battery in years. This is equal to the current date minus tlConfigExternalBattReplDate.
1.3.6.1.4.1.850.100.1.2.3DisplayStringread-onlycurrent
tlUpsInput
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.3
tlUpsInputNumVoltages
OBJECT-TYPE
The number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.
1.3.6.1.4.1.850.100.1.3.1NonNegativeIntegerread-onlycurrent
tlUpsInputVoltageTable
OBJECT-TYPE
A list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages.
1.3.6.1.4.1.850.100.1.3.2not-accessiblecurrent
tlUpsInputVoltageEntry
OBJECT-TYPE
An entry containing information applicable to a particular input voltage.
1.3.6.1.4.1.850.100.1.3.2.1not-accessiblecurrent
tlUpsInputVoltageIndex
OBJECT-TYPE
The input voltage identifier.
1.3.6.1.4.1.850.100.1.3.2.1.1PositiveIntegernot-accessiblecurrent
tlUpsInputVoltageType
OBJECT-TYPE
Whether voltage measured is phase to phase or phase to neutral.
1.3.6.1.4.1.850.100.1.3.2.1.2INTEGER {phaseToNeutral(0), phaseToPhase(1)}read-onlycurrent
tlUpsInputVoltage
OBJECT-TYPE
The magnitude of the present input voltage. A value of 6553 indicates Unknown.
1.3.6.1.4.1.850.100.1.3.2.1.3NonNegativeIntegerread-onlycurrent
tlUpsInputSourceSelect
OBJECT-TYPE
The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(0) for devices with a single input source. Setting this value is supported only on selected models.
1.3.6.1.4.1.850.100.1.3.3INTEGER {inputSourceA(0), inputSourceB(1)}read-writecurrent
tlUpsPhaseImbalance
OBJECT-TYPE
Percentage of imbalance of the 3 phases.
1.3.6.1.4.1.850.100.1.3.4INTEGERread-onlycurrent
tlUpsInputSourceAvailability
OBJECT-TYPE
The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available.
1.3.6.1.4.1.850.100.1.3.5INTEGER {none(0), inputSourceA(1), inputSourceB(2), inputSourceAB(3)}read-onlycurrent
tlUpsInputSourceInUse
OBJECT-TYPE
The determination as to which one of two AC input lines is in use.
1.3.6.1.4.1.850.100.1.3.6INTEGER {inputSourceA(0), inputSourceB(1)}read-onlycurrent
tlUpsInputSourceTransitionCount
OBJECT-TYPE
The number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment.
1.3.6.1.4.1.850.100.1.3.7PositiveIntegerread-onlycurrent
tlUpsOutput
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.4
tlUpsOutputPowerTotal
OBJECT-TYPE
The power capacity of the device.
1.3.6.1.4.1.850.100.1.4.5PositiveIntegerread-onlycurrent
tlUpsOutputCircuits
OBJECT-TYPE
The number of output circuits. This variable indicates the number of rows in the output circuit table.
1.3.6.1.4.1.850.100.1.4.6NonNegativeIntegerread-onlycurrent
tlUpsOutputCircuitTable
OBJECT-TYPE
A list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits.
1.3.6.1.4.1.850.100.1.4.7not-accessiblecurrent
tlUpsOutputCircuitEntry
OBJECT-TYPE
An entry containing information applicable to a particular output circuit.
1.3.6.1.4.1.850.100.1.4.7.1not-accessiblecurrent
tlUpsOutputCircuitIndex
OBJECT-TYPE
The output circuit identifier.
1.3.6.1.4.1.850.100.1.4.7.1.1PositiveIntegernot-accessiblecurrent
tlUpsOutputCircuitStatus
OBJECT-TYPE
Whether the breaker is open or closed.
1.3.6.1.4.1.850.100.1.4.7.1.2INTEGER {open(0), closed(1)}read-onlycurrent
tlUpsOutputCircuitLoadCurrent
OBJECT-TYPE
The magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown.
1.3.6.1.4.1.850.100.1.4.7.1.3NonNegativeIntegerread-onlycurrent
tlUpsOutputCircuitVoltage
OBJECT-TYPE
The magnitude of the present circuit voltage in tenths of an volt.
1.3.6.1.4.1.850.100.1.4.7.1.4NonNegativeIntegerread-onlycurrent
tlUpsOutputCircuitPower
OBJECT-TYPE
The magnitude of the present power in watts. tenths of an amp.
1.3.6.1.4.1.850.100.1.4.7.1.5NonNegativeIntegerread-onlycurrent
tlUpsOutputCircuitPowerFactor
OBJECT-TYPE
The power factor of all receptacles in a given circuit as a %.
1.3.6.1.4.1.850.100.1.4.7.1.6NonNegativeIntegerread-onlycurrent
tlUpsAggregatePowerFactor
OBJECT-TYPE
The aggregrate power factor of all phases.
1.3.6.1.4.1.850.100.1.4.8PositiveIntegerread-onlycurrent
tlUpsAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.6
tlUpsAlarmsPresent
OBJECT-TYPE
The present number of active alarm conditions.
1.3.6.1.4.1.850.100.1.6.1Gauge32read-onlycurrent
tlUpsAlarmTable
OBJECT-TYPE
A list of alarm table entries.
1.3.6.1.4.1.850.100.1.6.2not-accessiblecurrent
tlUpsAlarmEntry
OBJECT-TYPE
An entry containing information applicable to a particular alarm.
1.3.6.1.4.1.850.100.1.6.2.1not-accessiblecurrent
tlUpsAlarmId
OBJECT-TYPE
A unique identifier for an alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.1PositiveIntegerread-onlycurrent
tlUpsAlarmDescr
OBJECT-TYPE
A description of the alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.2AutonomousTyperead-onlycurrent
tlUpsAlarmTime
OBJECT-TYPE
The value of sysUpTime when the alarm condition was detected.
1.3.6.1.4.1.850.100.1.6.2.1.3TimeStampread-onlycurrent
tlUpsAlarmDetail
OBJECT-TYPE
A textual description of the alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.4DisplayStringread-onlycurrent
tlUpsAlarmDeviceId
OBJECT-TYPE
A numeric identifier for the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.5PositiveIntegerread-onlycurrent
tlUpsAlarmDeviceName
OBJECT-TYPE
A string identifier for the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.6DisplayStringread-onlycurrent
tlUpsAlarmLocation
OBJECT-TYPE
The location of the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.7DisplayStringread-onlycurrent
tlUpsAlarmGroup
OBJECT-TYPE
The category/group of this alarm.
1.3.6.1.4.1.850.100.1.6.2.1.8INTEGER {critical(1), warning(2), info(3), status(4), offline(5), custom(6)}read-onlycurrent
tlUpsAlarmIp
OBJECT-TYPE
The originating IP address associated with this alarm.
1.3.6.1.4.1.850.100.1.6.2.1.9IpAddressread-onlycurrent
tlUpsAlarmMac
OBJECT-TYPE
The originating mac address associated with this alarm.
1.3.6.1.4.1.850.100.1.6.2.1.10DisplayStringread-onlycurrent
tlUpsWellKnownAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.6.3
tlUpsAlarmPrimaryPowerOutage
OBJECT-IDENTITY
The primary power source is not present.
1.3.6.1.4.1.850.100.1.6.3.1current
tlUpsAlarmSecondaryPowerOutage
OBJECT-IDENTITY
The secondary power source is not present.
1.3.6.1.4.1.850.100.1.6.3.2current
tlUpsAlarmLoadLevelAboveThreshold
OBJECT-IDENTITY
The load level is above the designated threshold.
1.3.6.1.4.1.850.100.1.6.3.3current
tlUpsAlarmOutputCurrentChanged
OBJECT-IDENTITY
The output current changed from its last known value.
1.3.6.1.4.1.850.100.1.6.3.4current
tlUpsAlarmBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more batteries have been determined to require replacement.
1.3.6.1.4.1.850.100.1.6.3.5current
tlUpsAlarmLoadOff
OBJECT-IDENTITY
The load is off.
1.3.6.1.4.1.850.100.1.6.3.6current
tlUpsAlarmUserDefined
OBJECT-IDENTITY
A user-defined event is in alarm.
1.3.6.1.4.1.850.100.1.6.3.7current
tlUpsAlarmBatteryBad
OBJECT-IDENTITY
One or more batteries have been determined to require replacement.
1.3.6.1.4.1.850.100.1.6.3.8current
tlUpsAlarmOnBattery
OBJECT-IDENTITY
The UPS is drawing power from the batteries.
1.3.6.1.4.1.850.100.1.6.3.9current
tlUpsAlarmLowBattery
OBJECT-IDENTITY
The remaining battery run-time is less than or equal to upsConfigLowBattTime.
1.3.6.1.4.1.850.100.1.6.3.10current
tlUpsAlarmDepletedBattery
OBJECT-IDENTITY
The UPS will be unable to sustain the present load when and if the utility power is lost.
1.3.6.1.4.1.850.100.1.6.3.11current
tlUpsAlarmTempBad
OBJECT-IDENTITY
A temperature is out of tolerance.
1.3.6.1.4.1.850.100.1.6.3.12current
tlUpsAlarmInputBad
OBJECT-IDENTITY
An input condition is out of tolerance.
1.3.6.1.4.1.850.100.1.6.3.13current
tlUpsAlarmOutputBad
OBJECT-IDENTITY
An output condition (other than OutputOverload) is out of tolerance.
1.3.6.1.4.1.850.100.1.6.3.14current
tlUpsAlarmOutputOverload
OBJECT-IDENTITY
The output load exceeds the UPS output capacity.
1.3.6.1.4.1.850.100.1.6.3.15current
tlUpsAlarmOnBypass
OBJECT-IDENTITY
The Bypass is presently engaged on the UPS.
1.3.6.1.4.1.850.100.1.6.3.16current
tlUpsAlarmBypassBad
OBJECT-IDENTITY
The Bypass is out of tolerance.
1.3.6.1.4.1.850.100.1.6.3.17current
tlUpsAlarmOutputOffAsRequested
OBJECT-IDENTITY
The UPS has shutdown as requested, i.e., the output is off.
1.3.6.1.4.1.850.100.1.6.3.18current
tlUpsAlarmUpsOffAsRequested
OBJECT-IDENTITY
The entire UPS has shutdown as commanded.
1.3.6.1.4.1.850.100.1.6.3.19current
tlUpsAlarmChargerFailed
OBJECT-IDENTITY
An uncorrected problem has been detected within the UPS charger subsystem.
1.3.6.1.4.1.850.100.1.6.3.20current
tlUpsAlarmUpsOutputOff
OBJECT-IDENTITY
The output of the UPS is in the off state.
1.3.6.1.4.1.850.100.1.6.3.21current
tlUpsAlarmUpsSystemOff
OBJECT-IDENTITY
The UPS system is in the off state.
1.3.6.1.4.1.850.100.1.6.3.22current
tlUpsAlarmFanFailure
OBJECT-IDENTITY
The failure of one or more fans in the UPS has been detected.
1.3.6.1.4.1.850.100.1.6.3.23current
tlUpsAlarmFuseFailure
OBJECT-IDENTITY
The failure of one or more fuses has been detected.
1.3.6.1.4.1.850.100.1.6.3.24current
tlUpsAlarmGeneralFault
OBJECT-IDENTITY
A general fault in the UPS has been detected.
1.3.6.1.4.1.850.100.1.6.3.25current
tlUpsAlarmDiagnosticTestFailed
OBJECT-IDENTITY
The result of the last diagnostic test indicates a failure.
1.3.6.1.4.1.850.100.1.6.3.26current
tlUpsAlarmCommunicationsLost
OBJECT-IDENTITY
A problem has been encountered in the communications between the agent and the UPS.
1.3.6.1.4.1.850.100.1.6.3.27current
tlUpsAlarmAwaitingPower
OBJECT-IDENTITY
The UPS output is off and the UPS is awaiting the return of input power.
1.3.6.1.4.1.850.100.1.6.3.28current
tlUpsAlarmShutdownPending
OBJECT-IDENTITY
A upsShutdownAfterDelay countdown is underway.
1.3.6.1.4.1.850.100.1.6.3.29current
tlUpsAlarmShutdownImminent
OBJECT-IDENTITY
The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.
1.3.6.1.4.1.850.100.1.6.3.30current
tlUpsAlarmTestInProgress
OBJECT-IDENTITY
A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.
1.3.6.1.4.1.850.100.1.6.3.31current
tlUpsAlarmCircuitBreaker1Open
OBJECT-IDENTITY
Circuit breakers #1 is open.
1.3.6.1.4.1.850.100.1.6.3.32current
tlUpsAlarmCircuitBreaker2Open
OBJECT-IDENTITY
Circuit breakers #2 is open.
1.3.6.1.4.1.850.100.1.6.3.33current
tlUpsAlarmCircuitBreaker3Open
OBJECT-IDENTITY
Circuit breakers #3 is open.
1.3.6.1.4.1.850.100.1.6.3.34current
tlUpsAlarmCircuitBreaker4Open
OBJECT-IDENTITY
Circuit breakers #4 is open.
1.3.6.1.4.1.850.100.1.6.3.35current
tlUpsAlarmCircuitBreaker5Open
OBJECT-IDENTITY
Circuit breakers #5 is open.
1.3.6.1.4.1.850.100.1.6.3.36current
tlUpsAlarmCircuitBreaker6Open
OBJECT-IDENTITY
Circuit breakers #6 is open.
1.3.6.1.4.1.850.100.1.6.3.37current
tlUpsAlarmCircuitBreaker7Open
OBJECT-IDENTITY
Circuit breakers #7 is open.
1.3.6.1.4.1.850.100.1.6.3.38current
tlUpsAlarmCircuitBreaker8Open
OBJECT-IDENTITY
Circuit breakers #8 is open.
1.3.6.1.4.1.850.100.1.6.3.39current
tlUpsAlarmCurrent1AboveThreshold
OBJECT-IDENTITY
The output current on line 1 exceeds load limits.
1.3.6.1.4.1.850.100.1.6.3.40current
tlUpsAlarmCurrent2AboveThreshold
OBJECT-IDENTITY
The output current on line 2 exceeds load limits.
1.3.6.1.4.1.850.100.1.6.3.41current
tlUpsAlarmCurrent3AboveThreshold
OBJECT-IDENTITY
The output current on line 3 exceeds load limits.
1.3.6.1.4.1.850.100.1.6.3.42current
tlUpsAlarmRuntimeBelowWarningLevel
OBJECT-IDENTITY
The battery seconds remaining is below warning level.
1.3.6.1.4.1.850.100.1.6.3.43current
tlUpsAlarmBusStartVoltageLow
OBJECT-IDENTITY
The inverter start up bus voltage is too low.
1.3.6.1.4.1.850.100.1.6.3.44current
tlUpsAlarmBusOverVoltage
OBJECT-IDENTITY
The inverter bus voltage is too high.
1.3.6.1.4.1.850.100.1.6.3.45current
tlUpsAlarmBusUnderVoltage
OBJECT-IDENTITY
The inverter bus voltage is too low.
1.3.6.1.4.1.850.100.1.6.3.46current
tlUpsAlarmBusVoltageUnbalanced
OBJECT-IDENTITY
The inverter bus voltage is not balanced.
1.3.6.1.4.1.850.100.1.6.3.47current
tlUpsAlarmInverterSoftStartBad
OBJECT-IDENTITY
The inverter bus voltage cannot reach desired voltage within a specified duration.
1.3.6.1.4.1.850.100.1.6.3.48current
tlUpsAlarmInverterOverVoltage
OBJECT-IDENTITY
The inverter voltage is too high.
1.3.6.1.4.1.850.100.1.6.3.49current
tlUpsAlarmInverterUnderVoltage
OBJECT-IDENTITY
The inverter voltage is too low.
1.3.6.1.4.1.850.100.1.6.3.50current
tlUpsAlarmInverterCircuitBad
OBJECT-IDENTITY
The inverter output is shorted.
1.3.6.1.4.1.850.100.1.6.3.51current
tlUpsAlarmBatteryOverVoltage
OBJECT-IDENTITY
The battery voltage is too high.
1.3.6.1.4.1.850.100.1.6.3.52current
tlUpsAlarmBatteryUnderVoltage
OBJECT-IDENTITY
The battery voltage is too low.
1.3.6.1.4.1.850.100.1.6.3.53current
tlUpsAlarmSiteWiringFault
OBJECT-IDENTITY
The utility input wiring is faulty.
1.3.6.1.4.1.850.100.1.6.3.54current
tlUpsAlarmOverTemperatureProtection
OBJECT-IDENTITY
The over temperature protection is activated.
1.3.6.1.4.1.850.100.1.6.3.55current
tlUpsAlarmOverCharged
OBJECT-IDENTITY
The UPS is over charged.
1.3.6.1.4.1.850.100.1.6.3.56current
tlUpsAlarmEPOActive
OBJECT-IDENTITY
The EPO is currently activate.
1.3.6.1.4.1.850.100.1.6.3.57current
tlUpsAlarmBypassFrequencyBad
OBJECT-IDENTITY
The bypass frequency is out of tolerance.
1.3.6.1.4.1.850.100.1.6.3.58current
tlUpsAlarmExternalSmartBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more external smart batteries have been determined to require replacement.
1.3.6.1.4.1.850.100.1.6.3.59current
tlUpsAlarmExternalNonSmartBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more external non-smart batteries have been determined to require replacement.
1.3.6.1.4.1.850.100.1.6.3.60current
tlUpsAlarmSmartBatteryCommLost
OBJECT-IDENTITY
Communications with the smart batteries was lost.
1.3.6.1.4.1.850.100.1.6.3.61current
tlUpsAlarmSourceAOutage
OBJECT-IDENTITY
Input power source A is not present.
1.3.6.1.4.1.850.100.1.6.3.62current
tlUpsAlarmSourceBOutage
OBJECT-IDENTITY
Input power source B is not present.
1.3.6.1.4.1.850.100.1.6.3.63current
tlUpsAlarmWatchdogReset
OBJECT-IDENTITY
The internal watchdog triggered a reset of the device.
1.3.6.1.4.1.850.100.1.6.3.64current
tlUpsAlarmDevName
OBJECT-TYPE
The name of the device, tlDevName, corresponding to the device that is associated with this alarm.
1.3.6.1.4.1.850.100.1.6.7DisplayStringread-onlydeprecated
tlUpsAlarmDevLocation
OBJECT-TYPE
The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm.
1.3.6.1.4.1.850.100.1.6.8DisplayStringread-onlydeprecated
tlUpsAlarmCategory
OBJECT-TYPE
The category, tlDevEvtCategory, of this alarm.
1.3.6.1.4.1.850.100.1.6.9Integer32read-onlydeprecated
tlUpsTest
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.7
tlUpsTestDate
OBJECT-TYPE
The date of the last self-test run on the ups, in the format YYYYMMDD.
1.3.6.1.4.1.850.100.1.7.1DisplayStringread-onlycurrent
tlUpsTestResultsDetail
OBJECT-TYPE
Result of the last self-test run on the ups.
1.3.6.1.4.1.850.100.1.7.2DisplayStringread-onlycurrent
tlUpsControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.8
tlUpsWatchdogSupported
OBJECT-TYPE
Indicates whether or not this UPS supports a watchdog reboot.
1.3.6.1.4.1.850.100.1.8.1TruthValueread-onlycurrent
tlUpsWatchdogSecsBeforeReboot
OBJECT-TYPE
The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature.
1.3.6.1.4.1.850.100.1.8.2NonNegativeIntegerread-writecurrent
tlUpsWellKnownControls
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.8.3
tlUpsControlSelfTest
OBJECT-TYPE
Set to TRUE to initiate Self Test
1.3.6.1.4.1.850.100.1.8.3.1TruthValueread-writecurrent
tlUpsControlRamp
OBJECT-TYPE
Set to TRUE to initiate Ramp
1.3.6.1.4.1.850.100.1.8.3.2TruthValueread-writecurrent
tlUpsControlShed
OBJECT-TYPE
Set to TRUE to initiate Shed
1.3.6.1.4.1.850.100.1.8.3.3TruthValueread-writecurrent
tlUpsControlUpsOn
OBJECT-TYPE
Set to TRUE to turn UPS on
1.3.6.1.4.1.850.100.1.8.3.4TruthValueread-writecurrent
tlUpsControlUpsOff
OBJECT-TYPE
Set to TRUE to turn UPS off
1.3.6.1.4.1.850.100.1.8.3.5TruthValueread-writecurrent
tlUpsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.9
tlUpsConfigBattReplDate
OBJECT-TYPE
The date on which the battery was last replaced, in the format YYYYMMDD.
1.3.6.1.4.1.850.100.1.9.1DisplayStringread-writecurrent
tlUpsConfigDisplayUnits
OBJECT-TYPE
Selects English or Metric display for all readings. This selection may not be available on all devices. Further, some devices may support this selection, but not via a software selector. In this latter case, selections must be performed on the device itself.
1.3.6.1.4.1.850.100.1.9.4INTEGER {english(0), metric(1)}read-writecurrent
tlUpsConfigExternalBattReplDate
OBJECT-TYPE
The date on which the external battery was last replaced, in the format YYYYMMDD.
1.3.6.1.4.1.850.100.1.9.5DisplayStringread-writecurrent
tlUpsOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.10
tlUpsOutletNumOutlets
OBJECT-TYPE
The number of available Outlets in this device.
1.3.6.1.4.1.850.100.1.10.1NonNegativeIntegerread-onlycurrent
tlUpsOutletTable
OBJECT-TYPE
A list of all device Outlets for all devices.
1.3.6.1.4.1.850.100.1.10.2not-accessiblecurrent
tlUpsOutletEntry
OBJECT-TYPE
An entry containing Outlet information applicable to a particular device managed by this agent.
1.3.6.1.4.1.850.100.1.10.2.1not-accessiblecurrent
tlUpsOutletIndex
OBJECT-TYPE
This is the index number of this Outlet for the device indicated by tlDeviceIndex.
1.3.6.1.4.1.850.100.1.10.2.1.1PositiveIntegerread-onlycurrent
tlUpsOutletState
OBJECT-TYPE
The current state of the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.2INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlUpsOutletType
OBJECT-TYPE
This is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1.3.6.1.4.1.850.100.1.10.2.1.3Integer32read-onlycurrent
tlUpsOutletControl
OBJECT-TYPE
Controls the state of the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.4INTEGER {turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlUpsOutletName
OBJECT-TYPE
A string identifying the devices attached to the output(s) of the device.
1.3.6.1.4.1.850.100.1.10.2.1.5DisplayStringread-writecurrent
tlUpsOutletRampAction
OBJECT-TYPE
The ramp action to take on the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.6INTEGER {remainOff(0), turnOnAfterDelay(1)}read-writecurrent
tlUpsOutletRampDataType
OBJECT-TYPE
The type of data associated with ramp action.
1.3.6.1.4.1.850.100.1.10.2.1.7INTEGER {delayInSeconds(0)}read-writecurrent
tlUpsOutletRampData
OBJECT-TYPE
The data value associated with type of ramp data.
1.3.6.1.4.1.850.100.1.10.2.1.8Integer32read-writecurrent
tlUpsOutletShedAction
OBJECT-TYPE
The shed action to take on the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.9INTEGER {remainOn(0), turnOffAfterDelay(1)}read-writecurrent
tlUpsOutletShedDataType
OBJECT-TYPE
The type of data associated with shed action.
1.3.6.1.4.1.850.100.1.10.2.1.10INTEGER {delayInSeconds(0)}read-writecurrent
tlUpsOutletShedData
OBJECT-TYPE
The data value associated with type of shed data.
1.3.6.1.4.1.850.100.1.10.2.1.11Integer32read-writecurrent
tlUpsOutletGroupNdx
OBJECT-TYPE
tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped.
1.3.6.1.4.1.850.100.1.10.2.1.12Integer32read-writecurrent
tlUpsOutletCurrent
OBJECT-TYPE
The value of this outlet's current, represented as 0.1A.
1.3.6.1.4.1.850.100.1.10.2.1.13PositiveIntegerread-onlycurrent
tlUpsOutletPower
OBJECT-TYPE
The value of this outlet's power in watts.
1.3.6.1.4.1.850.100.1.10.2.1.14PositiveIntegerread-onlycurrent
tlUpsOutletGroup
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.11
tlUpsOutletNumOutletGroups
OBJECT-TYPE
The number of available Outlet Groups in this device.
1.3.6.1.4.1.850.100.1.11.1NonNegativeIntegerread-onlycurrent
tlUpsOutletGroupTable
OBJECT-TYPE
A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups.
1.3.6.1.4.1.850.100.1.11.2not-accessiblecurrent
tlUpsOutletGroupEntry
OBJECT-TYPE
An entry containing outlet group information applicable to a particular device managed by this agent
1.3.6.1.4.1.850.100.1.11.2.1not-accessiblecurrent
tlUpsOutletGroupIndex
OBJECT-TYPE
This is the index number of this load group for the device.
1.3.6.1.4.1.850.100.1.11.2.1.1PositiveIntegerread-onlycurrent
tlUpsOutletGroupRowStatus
OBJECT-TYPE
Row status for the tlUpsOutletGroupTable
1.3.6.1.4.1.850.100.1.11.2.1.2RowStatusread-writecurrent
tlUpsOutletGroupName
OBJECT-TYPE
The name of this outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.3DisplayStringread-writecurrent
tlUpsOutletGroupDesc
OBJECT-TYPE
A description for this outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.4DisplayStringread-writecurrent
tlUpsOutletGroupState
OBJECT-TYPE
The current state of the outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.5INTEGER {unknown(0), off(1), on(2), mixed(3)}read-onlycurrent
tlUpsOutletGroupControl
OBJECT-TYPE
Controls the state of every outlet associated with the group.
1.3.6.1.4.1.850.100.1.11.2.1.6INTEGER {turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlUpsMainOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.12
tlUpsMainOutletState
OBJECT-TYPE
The current state of the main output of the device.
1.3.6.1.4.1.850.100.1.12.1INTEGER {unknown(0), off(1), on(2), mixed(3)}read-onlycurrent
tlUpsMainOutletControllable
OBJECT-TYPE
Indicates if this device has controllable outlets
1.3.6.1.4.1.850.100.1.12.2TruthValueread-onlycurrent
tlUpsMainOutletControl
OBJECT-TYPE
Controls the state of the main outlet of the device.
1.3.6.1.4.1.850.100.1.12.3INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlUpsEnvironment
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.1.13
tlUpsTemperature
OBJECT-TYPE
The ambient temperature. The measurement returned will either be in units of Celsius (C) or Fahrenheit (F) depending upon whether Metric or English was selected for the reading by tlUpsConfigDisplayUnits.
1.3.6.1.4.1.850.100.1.13.1Integer32read-onlycurrent
tlUpsTraps
OBJECT-IDENTITY
1.3.6.1.4.1.850.100.2
tlEnviroSense
OBJECT-IDENTITY
1.3.6.1.4.1.850.101
tlEnvEnvironment
OBJECT-IDENTITY
1.3.6.1.4.1.850.101.1
tlEnvTemperatureData
OBJECT-IDENTITY
1.3.6.1.4.1.850.101.1.1
tlEnvTemperatureC
OBJECT-TYPE
The ambient temperature (C).
1.3.6.1.4.1.850.101.1.1.1Integer32read-onlycurrent
tlEnvTemperatureF
OBJECT-TYPE
The ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.2Integer32read-onlycurrent
tlEnvTemperatureLowLimit
OBJECT-TYPE
The lower alarm limit for ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.3Integer32read-writecurrent
tlEnvTemperatureHighLimit
OBJECT-TYPE
The upper alarm limit for ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.4Integer32read-writecurrent
tlEnvTemperatureInAlarm
OBJECT-TYPE
Indicates whether or not temperature is in alarm.
1.3.6.1.4.1.850.101.1.1.5TruthValueread-onlycurrent
tlEnvHumidityData
OBJECT-IDENTITY
1.3.6.1.4.1.850.101.1.2
tlEnvHumidity
OBJECT-TYPE
The ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.1Integer32read-onlycurrent
tlEnvHumidityLowLimit
OBJECT-TYPE
The lower alarm limit for ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.2Integer32read-writecurrent
tlEnvHumidityHighLimit
OBJECT-TYPE
The upper alarm limit for ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.3Integer32read-writecurrent
tlEnvHumidityInAlarm
OBJECT-TYPE
Indicates whether or not humidity is in alarm.
1.3.6.1.4.1.850.101.1.2.4TruthValueread-onlycurrent
tlEnvContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.101.2
tlEnvContactTable
OBJECT-TYPE
A table of contacts.
1.3.6.1.4.1.850.101.2.1not-accessiblecurrent
tlEnvContactEntry
OBJECT-TYPE
An entry containing information applicable to a particular contact.
1.3.6.1.4.1.850.101.2.1.1not-accessiblecurrent
tlEnvContactIndex
OBJECT-TYPE
The table row index for the contact.
1.3.6.1.4.1.850.101.2.1.1.1PositiveIntegerread-onlycurrent
tlEnvContactName
OBJECT-TYPE
The name or description of the contact.
1.3.6.1.4.1.850.101.2.1.1.2DisplayStringread-writecurrent
tlEnvContactStatus
OBJECT-TYPE
The current status of the contact.
1.3.6.1.4.1.850.101.2.1.1.3INTEGER {normal(0), alarm(1)}read-onlycurrent
tlEnvContactConfig
OBJECT-TYPE
The configuration of the contact.
1.3.6.1.4.1.850.101.2.1.1.4INTEGER {normallyOpen(0), normallyClosed(1)}read-writecurrent
tlCooling
OBJECT-IDENTITY
1.3.6.1.4.1.850.103
tlCoolingEnvironment
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1
tlCoolingIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1.1
tlCoolingModel
OBJECT-TYPE
The model name for the AC Unit.
1.3.6.1.4.1.850.103.1.1.1DisplayStringread-onlycurrent
tlCoolingManufacturer
OBJECT-TYPE
The manufacturer of the AC Unit.
1.3.6.1.4.1.850.103.1.1.2DisplayStringread-onlycurrent
tlCoolingSerialNumber
OBJECT-TYPE
The serial number of the AC unit.
1.3.6.1.4.1.850.103.1.1.3DisplayStringread-onlycurrent
tlCoolingFirmwareVersion
OBJECT-TYPE
The firmware version of the AC Unit.
1.3.6.1.4.1.850.103.1.1.4DisplayStringread-onlycurrent
tlCoolingHostSoftwareVersion
OBJECT-TYPE
The hardware version of the AC unit.
1.3.6.1.4.1.850.103.1.1.5DisplayStringread-onlycurrent
tlCoolingName
OBJECT-TYPE
The user defined name for the AC Unit.
1.3.6.1.4.1.850.103.1.1.6DisplayStringread-writecurrent
tlCoolingLocation
OBJECT-TYPE
The user defined location of the AC Unit.
1.3.6.1.4.1.850.103.1.1.7DisplayStringread-writecurrent
tlCoolingStatus
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1.2
tlCoolingCondOutletTemp
OBJECT-TYPE
The condenser outlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.1INTEGERread-onlycurrent
tlCoolingCondInletTemp
OBJECT-TYPE
The condenser inlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.2INTEGERread-onlycurrent
tlCoolingRefrigerantTemp
OBJECT-TYPE
The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.3INTEGERread-onlycurrent
tlCoolingEvapSurfaceTemp
OBJECT-TYPE
The surface temperature of the evaporator in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.4INTEGERread-onlycurrent
tlCoolingSuctionPressure
OBJECT-TYPE
The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.5INTEGERread-onlycurrent
tlCoolingDischargePressure
OBJECT-TYPE
The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.6INTEGERread-onlycurrent
tlCoolingEvapFanSpeed
OBJECT-TYPE
The current speed of the evaporator fan.
1.3.6.1.4.1.850.103.1.2.7INTEGER {off(0), low(1), medLow(2), med(3), medHi(4), hi(5)}read-onlycurrent
tlCoolingCondFanSpeed
OBJECT-TYPE
The current speed of the condenser fan.
1.3.6.1.4.1.850.103.1.2.8INTEGER {off(0), low(1), hi(2)}read-onlycurrent
tlCoolingCompFrequency
OBJECT-TYPE
The operating frequency of the compressor in tenths of Arms.
1.3.6.1.4.1.850.103.1.2.9INTEGERread-onlycurrent
tlCoolingEEVPercentage
OBJECT-TYPE
The opening percentage of the EEV.
1.3.6.1.4.1.850.103.1.2.10INTEGERread-onlycurrent
tlCoolingUnitCurrent
OBJECT-TYPE
The the total current draw of the unit in tenths of Arms.
1.3.6.1.4.1.850.103.1.2.11INTEGERread-onlycurrent
tlCoolingFanCurrent
OBJECT-TYPE
Thethe current draw of the Evaporator and Condenser fans in tents of Arms.
1.3.6.1.4.1.850.103.1.2.12INTEGERread-onlycurrent
tlCoolingCompCurrent
OBJECT-TYPE
The operating current of the compressor in Arms.
1.3.6.1.4.1.850.103.1.2.13INTEGERread-onlycurrent
tlCoolingReturnAirTemp
OBJECT-TYPE
The return air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.14INTEGERread-onlycurrent
tlCoolingSuctionTemp
OBJECT-TYPE
The temperature of the compressor suction line in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.15INTEGERread-onlycurrent
tlCoolingSupplyAirTemp
OBJECT-TYPE
The supply air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits.
1.3.6.1.4.1.850.103.1.2.16INTEGERread-onlycurrent
tlCoolingRunTimes
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1.3
tlCoolingAirFilterRunHours
OBJECT-TYPE
Total hours the air filter has been under operation.
1.3.6.1.4.1.850.103.1.3.1Integer32read-onlycurrent
tlCoolingEvapFanRunDays
OBJECT-TYPE
Total days the evaporator fan has been under operation.
1.3.6.1.4.1.850.103.1.3.2Integer32read-onlycurrent
tlCoolingCondFanRunDays
OBJECT-TYPE
Total days the condenser fan has been under operation.
1.3.6.1.4.1.850.103.1.3.3Integer32read-onlycurrent
tlCoolingCompressorRunDays
OBJECT-TYPE
Total days the compressor has been under operation.
1.3.6.1.4.1.850.103.1.3.4Integer32read-onlycurrent
tlCoolingCondPumpRunDays
OBJECT-TYPE
Total days the condensate pump has been under operation.
1.3.6.1.4.1.850.103.1.3.5Integer32read-onlycurrent
tlCoolingAtomizerRunDays
OBJECT-TYPE
Total days the atomizer has been under operation.
1.3.6.1.4.1.850.103.1.3.6Integer32read-onlycurrent
tlCoolingConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1.4
tlCoolingOnOff
OBJECT-TYPE
Turn the unit off or on.
1.3.6.1.4.1.850.103.1.4.1INTEGER {turnOffUnit(0), turnOnUnit(1)}read-writecurrent
tlCoolingSetPointTemp
OBJECT-TYPE
The set point temperature the unit will control the temperature to in tenths of degrees in Celsius or Fahrenheit based upon tleCoolDisplayUnits.
1.3.6.1.4.1.850.103.1.4.2INTEGERread-writecurrent
tlCoolingAutoStart
OBJECT-TYPE
Specified if the unit should start automatically on power up.
1.3.6.1.4.1.850.103.1.4.3INTEGER {disabled(0), enabled(1)}read-writecurrent
tlCoolingFanSpeedOverride
OBJECT-TYPE
Speed of evaporator fan set by the user.
1.3.6.1.4.1.850.103.1.4.4INTEGER {autoFanSpeed(0), low(1), medLow(2), med(3), medHi(4), hi(5)}read-writecurrent
tlCoolingControlType
OBJECT-TYPE
Which temperature to be used as a control point.
1.3.6.1.4.1.850.103.1.4.5INTEGER {returnAirTemp(0), remoteTemperature(1)}read-writecurrent
tlCoolingCurrentRemoteTemp
OBJECT-TYPE
The external remote temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlCoolingDisplayUnits
1.3.6.1.4.1.850.103.1.4.6INTEGERread-writecurrent
tlCoolingDisplayUnits
OBJECT-TYPE
Selects English or Metric display for all readings.
1.3.6.1.4.1.850.103.1.4.7INTEGER {metric(0), english(1)}read-writecurrent
tlCoolingBeepOnKey
OBJECT-TYPE
Indicates if the display sounds a beep when a key is pressed.
1.3.6.1.4.1.850.103.1.4.8INTEGER {noBeep(0), beepOn(1)}read-writecurrent
tlCoolingOutputRelaySource
OBJECT-TYPE
The alarm level that causes the ouput relay to activate.
1.3.6.1.4.1.850.103.1.4.9INTEGER {disabled(0), allAlarmsAndWarnings(1), criticalAlarmsOnly(2)}read-writecurrent
tlCoolingOffOnLeak
OBJECT-TYPE
Indicates if the unit should stop cooling when leak input is activated.
1.3.6.1.4.1.850.103.1.4.10INTEGER {turnOff(0), alarmOnly(1)}read-writecurrent
tlCoolingOffOnInputContact
OBJECT-TYPE
Indicates if the unit should stop cooling when input contact is activated.
1.3.6.1.4.1.850.103.1.4.11INTEGER {turnOff(0), alarmOnly(1)}read-writecurrent
tlCoolingInputContactType
OBJECT-TYPE
The input contact type.
1.3.6.1.4.1.850.103.1.4.12INTEGER {ncRelay(0), noRelay(1)}read-writecurrent
tlCoolingOutputRelayDefault
OBJECT-TYPE
Type of contact to make when output relay is activated.
1.3.6.1.4.1.850.103.1.4.13INTEGER {nc(0), no(1)}read-writecurrent
tlCoolingAirFilterInterval
OBJECT-TYPE
The number of weeks before the air filter needs to be changed.
1.3.6.1.4.1.850.103.1.4.14Integer32read-writecurrent
tlCoolingWaterLeakContactType
OBJECT-TYPE
The input contact type.
1.3.6.1.4.1.850.103.1.4.15INTEGER {noRelay(0), ncRelay(1)}read-writecurrent
tlCoolingThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.1.5
tlCoolingMaxAirFilterRunHours
OBJECT-TYPE
The maximum interval for air filter run hours before warning is annunciated.
1.3.6.1.4.1.850.103.1.5.1Integer32read-writecurrent
tlCoolingEnableAirFilterAlarm
OBJECT-TYPE
When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded.
1.3.6.1.4.1.850.103.1.5.2INTEGER {disabled(0), enabled(1)}read-writecurrent
tlCoolingMaxSupplyTemp
OBJECT-TYPE
Maximum allowed supply air temperature before firing an alarm.
1.3.6.1.4.1.850.103.1.5.3INTEGERread-writecurrent
tlCoolingMinSupplyTemp
OBJECT-TYPE
Minimum allowed supply air temperature allowed before firing an alarm.
1.3.6.1.4.1.850.103.1.5.4INTEGERread-writecurrent
tlCoolingTempDiffAlarm
OBJECT-TYPE
Maximum allowed air temperature deviation from set allowed before firing an alarm.
1.3.6.1.4.1.850.103.1.5.5INTEGERread-writecurrent
tlCoolingMaxReturnAirTemp
OBJECT-TYPE
When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded.
1.3.6.1.4.1.850.103.1.5.6INTEGERread-writecurrent
tlCoolingAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.6
tlCoolingWellKnownAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.103.6.3
tlCoolingSupplyAirSensorFault
OBJECT-IDENTITY
The supply air sensor is in fault.
1.3.6.1.4.1.850.103.6.3.1current
tlCoolingReturnAirSensorFault
OBJECT-IDENTITY
The return air sensor is in fault.
1.3.6.1.4.1.850.103.6.3.2current
tlCoolingCondenserInletAirSensorFault
OBJECT-IDENTITY
The condenser inlet air sensor is in fault.
1.3.6.1.4.1.850.103.6.3.3current
tlCoolingCondenserOutletAirSensorFault
OBJECT-IDENTITY
The condenser outlet air sensor is in fault.
1.3.6.1.4.1.850.103.6.3.4current
tlCoolingSuctionTemperatureSensorFault
OBJECT-IDENTITY
The suction temperature sensor is in fault.
1.3.6.1.4.1.850.103.6.3.5current
tlCoolingEvaporatorTemperatureSensorFault
OBJECT-IDENTITY
The evaporator temperature sensor is in fault.
1.3.6.1.4.1.850.103.6.3.6current
tlCoolingAirFilterClogged
OBJECT-IDENTITY
The air filter is clogged.
1.3.6.1.4.1.850.103.6.3.7current
tlCoolingAirFilterRunHoursViolation
OBJECT-IDENTITY
The air filter run hours was violated.
1.3.6.1.4.1.850.103.6.3.8current
tlCoolingSuctionPressureSensorFault
OBJECT-IDENTITY
The suction pressure sensor is in fault.
1.3.6.1.4.1.850.103.6.3.9current
tlCoolingInverterCommunicationsFault
OBJECT-IDENTITY
The inverter communications is in fault.
1.3.6.1.4.1.850.103.6.3.10current
tlCoolingRemoteShutdownViaInputContact
OBJECT-IDENTITY
A remote shutdown was triggerd by an input contact.
1.3.6.1.4.1.850.103.6.3.11current
tlCoolingCondensatePumpFault
OBJECT-IDENTITY
The condensate pump is in fault.
1.3.6.1.4.1.850.103.6.3.12current
tlCoolingLowRefrigerantStartupFault
OBJECT-IDENTITY
The low refrigerant startup is in fault.
1.3.6.1.4.1.850.103.6.3.13current
tlCoolingCondenserFanFault
OBJECT-IDENTITY
The condenser fan is in fault.
1.3.6.1.4.1.850.103.6.3.14current
tlCoolingCondenserFailure
OBJECT-IDENTITY
The condenser has failed.
1.3.6.1.4.1.850.103.6.3.15current
tlCoolingEvaporatorCoolingFailure
OBJECT-IDENTITY
The evaporator cooling is in fault.
1.3.6.1.4.1.850.103.6.3.16current
tlCoolingReturnAirTempHigh
OBJECT-IDENTITY
The return air temperature is high.
1.3.6.1.4.1.850.103.6.3.17current
tlCoolingSupplyAirTempHigh
OBJECT-IDENTITY
The supply air temperature is high.
1.3.6.1.4.1.850.103.6.3.18current
tlCoolingEvaporatorFailure
OBJECT-IDENTITY
The evaporator has failed.
1.3.6.1.4.1.850.103.6.3.19current
tlCoolingEvaporatorFreezeUp
OBJECT-IDENTITY
The evaporator is frozen.
1.3.6.1.4.1.850.103.6.3.20current
tlCoolingDischargePressureHigh
OBJECT-IDENTITY
The discharge pressure is high.
1.3.6.1.4.1.850.103.6.3.21current
tlCoolingPressureGaugeFailure
OBJECT-IDENTITY
The pressure gauge has failed.
1.3.6.1.4.1.850.103.6.3.22current
tlCoolingDischargePressurePersistentHigh
OBJECT-IDENTITY
The discharge pressure is persistently high.
1.3.6.1.4.1.850.103.6.3.23current
tlCoolingSuctionPressureLowStartFailure
OBJECT-IDENTITY
Cannot start due to low suction pressure.
1.3.6.1.4.1.850.103.6.3.24current
tlCoolingSuctionPressureLow
OBJECT-IDENTITY
The suction pressure is low.
1.3.6.1.4.1.850.103.6.3.25current
tlCoolingSuctionPressurePersistentLow
OBJECT-IDENTITY
The suction pressure is persistently low.
1.3.6.1.4.1.850.103.6.3.26current
tlCoolingStartupLinePressureImbalance
OBJECT-IDENTITY
The startup line pressure is in imbalance.
1.3.6.1.4.1.850.103.6.3.27current
tlCoolingCompressorFailure
OBJECT-IDENTITY
The compressor has failed.
1.3.6.1.4.1.850.103.6.3.28current
tlCoolingCurrentLimit
OBJECT-IDENTITY
The current is out of range.
1.3.6.1.4.1.850.103.6.3.29current
tlCoolingWaterLeak
OBJECT-IDENTITY
Water is leaking.
1.3.6.1.4.1.850.103.6.3.30current
tlCoolingFanUnderCurrent
OBJECT-IDENTITY
The fan is under current.
1.3.6.1.4.1.850.103.6.3.31current
tlCoolingFanOverCurrent
OBJECT-IDENTITY
The fan is over current.
1.3.6.1.4.1.850.103.6.3.32current
tlCoolingDischargePressureSensorFault
OBJECT-IDENTITY
The discharge pressure sensor is in fault.
1.3.6.1.4.1.850.103.6.3.33current
tlCoolingWaterFull
OBJECT-IDENTITY
Water is Full.
1.3.6.1.4.1.850.103.6.3.34current
tlCoolingAutoCoolingOn
OBJECT-IDENTITY
Automatic cooling was activated to lower the temperature below the remote set point.
1.3.6.1.4.1.850.103.6.3.35current
tlCoolingPowerButtonPressed
OBJECT-IDENTITY
Power button was pressed on the front panel.
1.3.6.1.4.1.850.103.6.3.36current
tlCoolingDisconnectedFromDevice
OBJECT-IDENTITY
The device communications is disconnected.
1.3.6.1.4.1.850.103.6.3.37current
tlSrCoolNet
OBJECT-IDENTITY
1.3.6.1.4.1.850.104
tlSrCoolNetData
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.1
tlSrCoolNetIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.1.1
tlSrCoolNetModel
OBJECT-TYPE
The model name for the device attached to the SRCOOLNET.
1.3.6.1.4.1.850.104.1.1.1DisplayStringread-onlycurrent
tlSrCoolNetManufacturer
OBJECT-TYPE
The manufacturer of the AC Unit.
1.3.6.1.4.1.850.104.1.1.2DisplayStringread-onlycurrent
tlSrCoolNetSerialNumber
OBJECT-TYPE
The serial number of the SRCOOLNET device.
1.3.6.1.4.1.850.104.1.1.3DisplayStringread-onlycurrent
tlSrCoolNetHostSoftwareVersion
OBJECT-TYPE
The software version of the SRCOOLNET device.
1.3.6.1.4.1.850.104.1.1.4DisplayStringread-onlycurrent
tlSrCoolNetName
OBJECT-TYPE
The user defined name for the AC Unit.
1.3.6.1.4.1.850.104.1.1.5DisplayStringread-writecurrent
tlSrCoolNetLocation
OBJECT-TYPE
The user defined location of the AC Unit.
1.3.6.1.4.1.850.104.1.1.6DisplayStringread-writecurrent
tlSrCoolNetStatus
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.1.2
tlSrCoolNetMode
OBJECT-TYPE
The current mode of SRCOOLNET.
1.3.6.1.4.1.850.104.1.2.1INTEGER {off(0), idle(1), cooling(2), unknown(3), dehumidifying(4), defrost(5), notconnected(6)}read-onlycurrent
tlSrCoolNetFanSpeed
OBJECT-TYPE
The current speed of the fan.
1.3.6.1.4.1.850.104.1.2.2INTEGER {off(0), low(1), med(2), hi(3)}read-onlycurrent
tlSrCoolNetReturnAirTemp
OBJECT-TYPE
The return air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlSrCoolNetDisplayUnits.
1.3.6.1.4.1.850.104.1.2.3INTEGERread-onlycurrent
tlSrCoolNetWaterFull
OBJECT-TYPE
Indicates the water reservoir is full or not full.
1.3.6.1.4.1.850.104.1.2.4INTEGER {waterNotFull(0), waterFull(1)}read-onlycurrent
tlSrCoolNetCurrentRemoteTemp
OBJECT-TYPE
The EnviroSense temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlSrCoolNetDisplayUnits. Only available if EnviroSense is connected to SRCOOLNET.
1.3.6.1.4.1.850.104.1.2.5INTEGERread-onlycurrent
tlSrCoolNetDisplayUnits
OBJECT-TYPE
Selects English or Metric display for all readings. AC unit must be manually configured to match this setting.
1.3.6.1.4.1.850.104.1.2.6INTEGER {metric(0), english(1)}read-onlycurrent
tlSrCoolNetConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.1.3
tlSrCoolNetOnOff
OBJECT-TYPE
Turn the unit off or on.
1.3.6.1.4.1.850.104.1.3.1INTEGER {turnOffUnit(0), turnOnUnit(1)}read-writecurrent
tlSrCoolSetMode
OBJECT-TYPE
Set the operating mode of cooling unit. Unit must be ON to set mode.
1.3.6.1.4.1.850.104.1.3.2INTEGER {cooling(0), dehumidifying(1)}read-writecurrent
tlSrCoolNetSetPointTemp
OBJECT-TYPE
The local set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits.
1.3.6.1.4.1.850.104.1.3.3INTEGERread-writecurrent
tlSrCoolNetRemoteSetPointTemp
OBJECT-TYPE
The remote set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits. Only available when EnviroSense is connected to SRCOOLNET.
1.3.6.1.4.1.850.104.1.3.4INTEGERread-writecurrent
tlSrCoolNetFanSpeedSetting
OBJECT-TYPE
Set the fan speed of the AC unit.
1.3.6.1.4.1.850.104.1.3.5INTEGER {auto(0), low(1), med(2), high(3)}read-writecurrent
tlSrCoolNetRemoteSetpointEnable
OBJECT-TYPE
Use remote temperature setpoint for control point versus return air temp. Only available when EnviroSense is connected to SRCOOLNET.
1.3.6.1.4.1.850.104.1.3.6INTEGER {disable(0), enable(1)}read-writecurrent
tlSrCoolNetFanAlwaysOn
OBJECT-TYPE
Leave fans on when not cooling. Only available when EnviroSense is connected to SRCOOLNET.
1.3.6.1.4.1.850.104.1.3.7INTEGER {disable(0), enable(1)}read-writecurrent
tlSrCoolNetAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.2
tlSrCoolNetWellKnownAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.104.2.1
tlSrCoolNetWaterFullAlarm
OBJECT-IDENTITY
Water reservoir full.
1.3.6.1.4.1.850.104.2.1.1current

Notifications

NameOIDStatus
tlUpsTrapAlarmEntryAddedV1
NOTIFICATION-TYPE
This trap is sent each time an alarm is inserted into to the alarm table.
1.3.6.1.4.1.850.100.2.0.3
tlUpsTrapAlarmEntryRemovedV1
NOTIFICATION-TYPE
This trap is sent each time an alarm is removed from the alarm table.
1.3.6.1.4.1.850.100.2.0.4
tlUpsTrapAlarmEntryAdded
NOTIFICATION-TYPE
This trap is sent each time an alarm is inserted into to the alarm table.
1.3.6.1.4.1.850.100.2.3current
tlUpsTrapAlarmEntryRemoved
NOTIFICATION-TYPE
This trap is sent each time an alarm is removed from the alarm table.
1.3.6.1.4.1.850.100.2.4current
tlUpsTrapSystemStartup
NOTIFICATION-TYPE
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format)
1.3.6.1.4.1.850.100.2.5current
tlUpsTrapSystemShutdown
NOTIFICATION-TYPE
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format)
1.3.6.1.4.1.850.100.2.6current

Conformance

NameOIDStatus
tlUpsFullIdentGroup
OBJECT-GROUP
The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.1current
tlUpsFullBatteryGroup
OBJECT-GROUP
The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.2current
tlUpsFullAlarmObjsGroup
OBJECT-GROUP
The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.6.1current
tlUpsFullTestGroup
OBJECT-GROUP
The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.7current
tlUpsFullControlGroup
OBJECT-GROUP
The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.8current
tlUpsFullConfigGroup
OBJECT-GROUP
The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.9current
tlUpsFullOutletGroup
OBJECT-GROUP
The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.10current