Objects

NameOIDSyntaxAccessStatus
socomec
OBJECT-IDENTITY
1.3.6.1.4.1.4555
ups
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2
pdu
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30
dpduIdent
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30.1
dpduIdentManufacturer
OBJECT-TYPE
The EnviroStation Vendor.
1.3.6.1.4.1.4555.2.30.1.1DisplayString (SIZE(0..32))read-onlymandatory
dpduIdentModel
OBJECT-TYPE
The PDU Model designation.
1.3.6.1.4.1.4555.2.30.1.2DisplayString (SIZE(0..32))read-onlymandatory
dpduIdentSerialNumber
OBJECT-TYPE
The PDU serial number
1.3.6.1.4.1.4555.2.30.1.3DisplayString (SIZE(0..16))read-onlymandatory
dpduIdentPDUFirmwareVersion
OBJECT-TYPE
The PDU firmware version
1.3.6.1.4.1.4555.2.30.1.4DisplayString (SIZE(0..16))read-onlymandatory
dpduIdentAgentSoftwareVersion
OBJECT-TYPE
The PDU NMC software version
1.3.6.1.4.1.4555.2.30.1.5DisplayString (SIZE(0..16))read-onlymandatory
dpduIdentName
OBJECT-TYPE
A string identifying the PDU. This object should be set by the administrator.
1.3.6.1.4.1.4555.2.30.1.6DisplayString (SIZE(0..32))read-writemandatory
dpduAttachedDevices
OBJECT-TYPE
A string identifying the devices attached to the output(s) of the PDU. This object should be set by the administrator.
1.3.6.1.4.1.4555.2.30.1.7DisplayString (SIZE(0..63))read-writemandatory
dpduOutput
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30.2
dpduOutputFrequency
OBJECT-TYPE
The present output frequency in 1/10 Hz.
1.3.6.1.4.1.4555.2.30.2.1INTEGERread-onlymandatory
dpduOutputVoltage1
OBJECT-TYPE
The Output line 1 voltage of the PDU system in 1/10 V.
1.3.6.1.4.1.4555.2.30.2.2INTEGERread-onlymandatory
dpduOutputCurrent1
OBJECT-TYPE
The Output line 1 current of the PDU system in 1/10 A.
1.3.6.1.4.1.4555.2.30.2.3INTEGERread-onlymandatory
dpduOutputVoltage2
OBJECT-TYPE
The Output line 2 voltage of the PDU system in 1/10 V.
1.3.6.1.4.1.4555.2.30.2.4INTEGERread-onlymandatory
dpduOutputCurrent2
OBJECT-TYPE
The Output line 2 current of the PDU system in 1/10 A.
1.3.6.1.4.1.4555.2.30.2.5INTEGERread-onlymandatory
dpduOutputVoltage3
OBJECT-TYPE
The Output line 3 voltage of the PDU system in 1/10 V.
1.3.6.1.4.1.4555.2.30.2.6INTEGERread-onlymandatory
dpduOutputCurrent3
OBJECT-TYPE
The Output line 3 current of the PDU system in 1/10 A.
1.3.6.1.4.1.4555.2.30.2.7INTEGERread-onlymandatory
dpduAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30.3
dpduAlarmDisconnect
OBJECT-TYPE
Does the PDU disconnect?
1.3.6.1.4.1.4555.2.30.3.1INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL1LoadMajor
OBJECT-TYPE
L1 load major alarm
1.3.6.1.4.1.4555.2.30.3.2INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL1LoadMinor
OBJECT-TYPE
L1 load minor alarm
1.3.6.1.4.1.4555.2.30.3.3INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL1OutVoltMajor
OBJECT-TYPE
L1 output votage major alarm
1.3.6.1.4.1.4555.2.30.3.4INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL1OutVoltMinor
OBJECT-TYPE
L1 output voltage minor alarm
1.3.6.1.4.1.4555.2.30.3.5INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL2LoadMajor
OBJECT-TYPE
L2 load major alarm
1.3.6.1.4.1.4555.2.30.3.6INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL2LoadMinor
OBJECT-TYPE
L2 load minor alarm
1.3.6.1.4.1.4555.2.30.3.7INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL2OutVoltMajor
OBJECT-TYPE
L2 output votage major alarm
1.3.6.1.4.1.4555.2.30.3.8INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL2OutVoltMinor
OBJECT-TYPE
L2 output voltage minor alarm
1.3.6.1.4.1.4555.2.30.3.9INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL3LoadMajor
OBJECT-TYPE
L3 load major alarm
1.3.6.1.4.1.4555.2.30.3.10INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL3LoadMinor
OBJECT-TYPE
L3 load minor alarm
1.3.6.1.4.1.4555.2.30.3.11INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL3OutVoltMajor
OBJECT-TYPE
L3 output votage major alarm
1.3.6.1.4.1.4555.2.30.3.12INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL3OutVoltMinor
OBJECT-TYPE
L3 output voltage minor alarm
1.3.6.1.4.1.4555.2.30.3.13INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL12LoadMajor
OBJECT-TYPE
L1, L2 load major alarm
1.3.6.1.4.1.4555.2.30.3.14INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmL12LoadMinor
OBJECT-TYPE
L1, L2 load minor alarm
1.3.6.1.4.1.4555.2.30.3.15INTEGER {off(0), on(1)}read-onlymandatory
dpduEnvironment
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30.4
dpduEnvTemperature
OBJECT-TYPE
The ambient environmental temperature.
1.3.6.1.4.1.4555.2.30.4.1INTEGERread-onlymandatory
dpduEnvHumidity
OBJECT-TYPE
The environmental humidity.
1.3.6.1.4.1.4555.2.30.4.2INTEGERread-onlymandatory
dpduEnvSetTemperatureWarnLimit
OBJECT-TYPE
Alarm dpduEnvOverWarnTemperature on when the environmental temperature over the value.
1.3.6.1.4.1.4555.2.30.4.3INTEGERread-writemandatory
dpduEnvSetTemperatureAlarmLimit
OBJECT-TYPE
Alarm dpduEnvOverAlarmTemperature on when the environmental temperature over the value.
1.3.6.1.4.1.4555.2.30.4.4INTEGERread-writemandatory
dpduEnvSetHumidityWarnLimit
OBJECT-TYPE
Alarm dpduEnvOverWarnHumidity on when the environmental humidity over the value.
1.3.6.1.4.1.4555.2.30.4.5INTEGERread-writemandatory
dpduEnvSetHumidityAlarmLimit
OBJECT-TYPE
Alarm dpduEnvOverAlarmHumidity on when the environmental humidity over the value.
1.3.6.1.4.1.4555.2.30.4.6INTEGERread-writemandatory
dpduEnvSetEnvRelay1
OBJECT-TYPE
1.3.6.1.4.1.4555.2.30.4.7INTEGER {normalOpen(0), normalClose(1)}read-writemandatory
dpduEnvSetEnvRelay2
OBJECT-TYPE
1.3.6.1.4.1.4555.2.30.4.8INTEGER {normalOpen(0), normalClose(1)}read-writemandatory
dpduEnvSetEnvRelay3
OBJECT-TYPE
1.3.6.1.4.1.4555.2.30.4.9INTEGER {normalOpen(0), normalClose(1)}read-writemandatory
dpduEnvSetEnvRelay4
OBJECT-TYPE
1.3.6.1.4.1.4555.2.30.4.10INTEGER {normalOpen(0), normalClose(1)}read-writemandatory
dpduWarnOverEnvTemperature
OBJECT-TYPE
Does the environment over warning temperature?
1.3.6.1.4.1.4555.2.30.4.11INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmOverEnvTemperature
OBJECT-TYPE
Does the environment over alarm temperature?
1.3.6.1.4.1.4555.2.30.4.12INTEGER {off(0), on(1)}read-onlymandatory
dpduWarnmOverEnvHumidity
OBJECT-TYPE
Does the environment over warn humidity?
1.3.6.1.4.1.4555.2.30.4.13INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmOverEnvHumidity
OBJECT-TYPE
Does the environment over alarm humidity?
1.3.6.1.4.1.4555.2.30.4.14INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmEnvRelay1
OBJECT-TYPE
The alarm status of relay1.
1.3.6.1.4.1.4555.2.30.4.15INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmEnvRelay2
OBJECT-TYPE
The alarm status of relay2.
1.3.6.1.4.1.4555.2.30.4.16INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmEnvRelay3
OBJECT-TYPE
The alarm status of relay3.
1.3.6.1.4.1.4555.2.30.4.17INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmEnvRelay4
OBJECT-TYPE
The alarm status of relay4.
1.3.6.1.4.1.4555.2.30.4.18INTEGER {off(0), on(1)}read-onlymandatory
dpduAlarmEnvDisconnect
OBJECT-TYPE
To indicate the communication status of EnviroProbe.
1.3.6.1.4.1.4555.2.30.4.19INTEGER {no(0), yes(1)}read-onlymandatory
dpduTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4555.2.30.20

Notifications

NameOIDStatus
dpduCommunicationLost
NOTIFICATION-TYPE
Communication with the PDU failed.
1.3.6.1.4.1.4555.2.30.20.0.1
dpduCommunicationEstablished
NOTIFICATION-TYPE
Communication with the PDU reestablished.
1.3.6.1.4.1.4555.2.30.20.0.2
dpduL1LoadMajorAlarm
NOTIFICATION-TYPE
L1 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.3
dpduL1LoadMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.4
dpduL1LoadMinorAlarm
NOTIFICATION-TYPE
L1 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.5
dpduL1LoadMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.6
dpduL1OutVoltMajorAlarm
NOTIFICATION-TYPE
L1 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.7
dpduL1OutVoltMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.8
dpduL1OutVoltMinorAlarm
NOTIFICATION-TYPE
L1 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.9
dpduL1OutVoltMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.10
dpduL2LoadMajorAlarm
NOTIFICATION-TYPE
L2 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.11
dpduL2LoadMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L2 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.12
dpduL2LoadMinorAlarm
NOTIFICATION-TYPE
L2 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.13
dpduL2LoadMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L2 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.14
dpduL2OutVoltMajorAlarm
NOTIFICATION-TYPE
L2 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.15
dpduL2OutVoltMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L2 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.16
dpduL2OutVoltMinorAlarm
NOTIFICATION-TYPE
L2 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.17
dpduL2OutVoltMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L2 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.18
dpduL3LoadMajorAlarm
NOTIFICATION-TYPE
L3 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.19
dpduL3LoadMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L3 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.20
dpduL3LoadMinorAlarm
NOTIFICATION-TYPE
L3 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.21
dpduL3LoadMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L3 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.22
dpduL3OutVoltMajorAlarm
NOTIFICATION-TYPE
L3 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.23
dpduL3OutVoltMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L3 output voltage major alarm.
1.3.6.1.4.1.4555.2.30.20.0.24
dpduL3OutVoltMinorAlarm
NOTIFICATION-TYPE
L3 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.25
dpduL3OutVoltMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L3 output voltage minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.26
dpduL12LoadMajorAlarm
NOTIFICATION-TYPE
L1 L2 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.27
dpduL12LoadMajorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 L2 load major alarm.
1.3.6.1.4.1.4555.2.30.20.0.28
dpduL12LoadMinorAlarm
NOTIFICATION-TYPE
L1 L2 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.29
dpduL12LoadMinorAlarmRecover
NOTIFICATION-TYPE
Recover from L1 L2 load minor alarm.
1.3.6.1.4.1.4555.2.30.20.0.30
dpduEnvCommunicationLost
NOTIFICATION-TYPE
Communication with the environmental sensor failed.
1.3.6.1.4.1.4555.2.30.20.0.31
dpduEnvCommunicationEstablished
NOTIFICATION-TYPE
Communication with the environmental sensor reestablished.
1.3.6.1.4.1.4555.2.30.20.0.32
dpduEnvOverWarnTemperature
NOTIFICATION-TYPE
The environment over warning temperature.
1.3.6.1.4.1.4555.2.30.20.0.33
dpduNoLongerEnvOverWarnTemperature
NOTIFICATION-TYPE
The environment recovered from over warning temperature.
1.3.6.1.4.1.4555.2.30.20.0.34
dpduEnvOverWarnHumidity
NOTIFICATION-TYPE
The environment over warning humidity.
1.3.6.1.4.1.4555.2.30.20.0.35
dpduNoLongerEnvOverWarnHumidity
NOTIFICATION-TYPE
The environment recovered from over warning humidity.
1.3.6.1.4.1.4555.2.30.20.0.36
dpduEnvOverAlarmTemperature
NOTIFICATION-TYPE
The environment over alarm temperature.
1.3.6.1.4.1.4555.2.30.20.0.37
dpduNoLongerEnvOverAlarmTemperature
NOTIFICATION-TYPE
The environment recovered from over alarm temperature.
1.3.6.1.4.1.4555.2.30.20.0.38
dpduEnvOverAlarmHumidity
NOTIFICATION-TYPE
The environment over alarm humidity.
1.3.6.1.4.1.4555.2.30.20.0.39
dpduNoLongerEnvOverAlarmHumidity
NOTIFICATION-TYPE
The environment recovered from over alarm humidity.
1.3.6.1.4.1.4555.2.30.20.0.40
dpduEnvRelay1Alarm
NOTIFICATION-TYPE
The environment relay1 is not in normal state.
1.3.6.1.4.1.4555.2.30.20.0.41
dpduEnvRelay1Normal
NOTIFICATION-TYPE
The environment relay1 is in normal state.
1.3.6.1.4.1.4555.2.30.20.0.42
dpduEnvRelay2Alarm
NOTIFICATION-TYPE
The environment relay2 is not in normal state.
1.3.6.1.4.1.4555.2.30.20.0.43
dpduEnvRelay2Normal
NOTIFICATION-TYPE
The environment relay2 is in normal state.
1.3.6.1.4.1.4555.2.30.20.0.44
dpduEnvRelay3Alarm
NOTIFICATION-TYPE
The environment relay3 is not in normal state.
1.3.6.1.4.1.4555.2.30.20.0.45
dpduEnvRelay3Normal
NOTIFICATION-TYPE
The environment relay3 is in normal state.
1.3.6.1.4.1.4555.2.30.20.0.46
dpduEnvRelay4Alarm
NOTIFICATION-TYPE
The environment relay4 is not in normal state.
1.3.6.1.4.1.4555.2.30.20.0.47
dpduEnvRelay4Normal
NOTIFICATION-TYPE
The environment relay4 is in normal state.
1.3.6.1.4.1.4555.2.30.20.0.48