SNA-SDLC-MIB
- Registered at
- 1.3.6.1.2.1.41
- Last updated
- 1994-11-15 00:00
- Organization
- IETF SNA DLC MIB Working Group
- Namespace
- standard
- Source file
SNA-SDLC-MIB- Digest
sha256:e1f2964aee00c0e43f4dc2a6eed4a06895de61c8226ab0e1dc49976d83446e4c
Description
This is the MIB module for objects used to manage SDLC devices.
Contact
Wayne Clark Postal: cisco Systems, Inc. 3100 Smoketree Ct. Suite 1000 Raleigh, NC 27604 US Tel: +1 919 878 6958 E-Mail: wclark@cisco.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifAdminStatus, ifIndex, ifOperStatus |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso, mib-2 |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeInterval |
Imported by
2 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB SNA-SDLC-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sdlc OBJECT-IDENTITY | 1.3.6.1.2.1.41.1 | |||
| sdlcPortGroup OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.1 | |||
| sdlcPortAdminTable OBJECT-TYPE This table contains objects that can be changed to manage an SDLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the sdlcPortOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was changed after the interface was started. | 1.3.6.1.2.1.41.1.1.1 | not-accessible | current | |
| sdlcPortAdminEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.2.1.41.1.1.1.1 | not-accessible | current | |
| sdlcPortAdminName OBJECT-TYPE An octet string that defines the physical port to which this interface is assigned. It has implementation-specific significance. Its value shall be unique within the administered system. It must contain only ASCII printable characters. Should an implementation choose to accept a write operation for this object, it causes the logical port definition associated with the table instance to be moved to a different physical port. A write operation shall not take effect until the port is cycled inactive. | 1.3.6.1.2.1.41.1.1.1.1.1 | DisplayString (SIZE(1..10)) | read-write | current |
| sdlcPortAdminRole OBJECT-TYPE This object describes the role that the link station shall assume the next time a connection is established. Even though this is defined as a port object, it is a link station attribute in the sense that a role is per link station. However, it is not possible to vary link station roles on a particular port. For example, if an SDLC port is configured to primary, all link stations on that port must be primary. | 1.3.6.1.2.1.41.1.1.1.1.2 | INTEGER {primary(1), secondary(2), negotiable(3)} | read-write | current |
| sdlcPortAdminType OBJECT-TYPE This parameter defines whether the SDLC port is to connect to a leased or switched line. A write operation to this administrative value shall not take effect until the SDLC port has been cycled inactive. | 1.3.6.1.2.1.41.1.1.1.1.3 | INTEGER {leased(1), switched(2)} | read-write | current |
| sdlcPortAdminTopology OBJECT-TYPE This parameter defines whether the SDLC port is capable of operating in either a point-to-point or multipoint topology. sdlcPortAdminTopology == multipoint implies the port can also operate in a point-to-point topology. sdlcPortAdminTopology == pointToPoint does not imply the port can operate in a multipoint topology. A write operation to this administrative value shall not take effect until the SDLC port has been cycled inactive. | 1.3.6.1.2.1.41.1.1.1.1.4 | INTEGER {pointToPoint(1), multipoint(2)} | read-write | current |
| sdlcPortAdminISTATUS OBJECT-TYPE This parameter controls the initial value of the administrative status, ifAdminStatus, of this SDLC port at port start-up. Depending on the implementation, a write operation to this administrative object may not take effect until the SDLC port has been cycled inactive. | 1.3.6.1.2.1.41.1.1.1.1.5 | INTEGER {inactive(1), active(2)} | read-write | current |
| sdlcPortAdminACTIVTO OBJECT-TYPE This parameter defines the period of time (in 1/100ths of a second) that the port will allow a switched line to remain inactive before disconnecting. A switched line is considered to be inactive if there are no I-Frames being transferred. A value of zero indicates no timeout. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminType == switched The object descriptor contains the name of an NCP configuration parameter, ACTIVTO. Please note that the value of this object represents 1/100ths of a second while the NCP ACTIVTO is represented in seconds. | 1.3.6.1.2.1.41.1.1.1.1.6 | TimeInterval | read-write | current |
| sdlcPortAdminPAUSE OBJECT-TYPE This object defines the minimum elapsed time (in 1/100ths of a second) between any two traversals of the poll list for a primary SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. The object descriptor contains the name of an NCP configuration parameter, PAUSE. Please note that the value of this object represents 1/100ths of a second while the NCP PAUSE is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary | 1.3.6.1.2.1.41.1.1.1.1.7 | TimeInterval | read-write | current |
| sdlcPortAdminSERVLIM OBJECT-TYPE This object defines the number of times the active poll list will be traversed before polling a station on the slow poll list for a primary, multipoint SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary and sdlcPortAdminTopology == multipoint | 1.3.6.1.2.1.41.1.1.1.1.8 | Integer32 | read-write | current |
| sdlcPortAdminSlowPollTimer OBJECT-TYPE This object describes the elapsed time (in 1/100ths of a second) between polls for failed secondary link station addresses. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary and sdlcPortAdminTopology == multipoint | 1.3.6.1.2.1.41.1.1.1.1.9 | TimeInterval | read-write | current |
| sdlcPortOperTable OBJECT-TYPE This table contains current SDLC port parameters. Many of these objects have corresponding objects inthe sdlcPortAdminTable. | 1.3.6.1.2.1.41.1.1.2 | not-accessible | current | |
| sdlcPortOperEntry OBJECT-TYPE Currently set parameters for a specific SDLC port. | 1.3.6.1.2.1.41.1.1.2.1 | not-accessible | current | |
| sdlcPortOperName OBJECT-TYPE An octet string that describes the physical port to which this interface is currently attached. It has implementation-specific significance. | 1.3.6.1.2.1.41.1.1.2.1.1 | DisplayString (SIZE(1..8)) | read-only | current |
| sdlcPortOperRole OBJECT-TYPE This object describes the role that the link station has assumed on this connection. Even though this is defined as a port object, it is a link station attribute in the sense that a role is per link station. However, it is not possible to vary link station roles on a particular port. For example, if an SDLC port is configured to primary, all link stations on that port must be primary. The value of sdlcPortOperRole is undefined(3) whenever the link station role has not yet been established by the mode setting command. | 1.3.6.1.2.1.41.1.1.2.1.2 | INTEGER {primary(1), secondary(2), undefined(3)} | read-only | current |
| sdlcPortOperType OBJECT-TYPE This parameter defines whether the SDLC port is currently operating as though connected to a leased or switched line. | 1.3.6.1.2.1.41.1.1.2.1.3 | INTEGER {leased(1), switched(2)} | read-only | current |
| sdlcPortOperTopology OBJECT-TYPE This parameter defines whether the SDLC port is currently operating in a point-to-point or multipoint topology. | 1.3.6.1.2.1.41.1.1.2.1.4 | INTEGER {pointToPoint(1), multipoint(2)} | read-only | current |
| sdlcPortOperISTATUS OBJECT-TYPE This parameter describes the initial value of the administrative status, ifAdminStatus, of this SDLC port at last port start-up. | 1.3.6.1.2.1.41.1.1.2.1.5 | INTEGER {inactive(1), active(2)} | read-only | current |
| sdlcPortOperACTIVTO OBJECT-TYPE This parameter defines the period of time (in 100ths of a second) that the port will allow a switched line to remain inactive before disconnecting. A switched line is considered to be inactive if there are no I-Frames being transferred. The object descriptor contains the name of an NCP configuration parameter, ACTIVTO. Please note that the value of this object represents 1/100ths of a second while the NCP ACTIVTO is represented in seconds. A value of zero indicates no timeout. | 1.3.6.1.2.1.41.1.1.2.1.6 | TimeInterval | read-only | current |
| sdlcPortOperPAUSE OBJECT-TYPE This object describes the current minimum elapsed time (in 1/100ths of a second) between any two traversals of the poll list for a primary SDLC port. The object descriptor contains the name of an NCP configuration parameter, PAUSE. Please note that the value of this object represents 1/100ths of a second while the NCP PAUSE is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary | 1.3.6.1.2.1.41.1.1.2.1.7 | TimeInterval | read-only | current |
| sdlcPortOperSlowPollMethod OBJECT-TYPE This object defines the exact method that is in effect for periodically polling failed secondary link station addresses. If sdlcPortOperSlowPollMethod == servlim, then sdlcPortOperSERVLIM defines the actual polling characteristics. If sdlcPortOperSlowPollMethod == pollpause, then sdlcPortOperSlowPollTimer defines the actual polling characteristics. If sdlcPortOperSlowPollMethod == other, then the polling characteristics are modeled in vendor-specific objects. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint | 1.3.6.1.2.1.41.1.1.2.1.8 | INTEGER {servlim(1), pollpause(2), other(3)} | read-only | current |
| sdlcPortOperSERVLIM OBJECT-TYPE This object describes the number of times the active poll list is currently being traversed before polling a station on the slow poll list for a primary, multipoint SDLC port. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint | 1.3.6.1.2.1.41.1.1.2.1.9 | Integer32 | read-only | current |
| sdlcPortOperSlowPollTimer OBJECT-TYPE This object describes the elapsed time (in 1/100ths of a second) between polls for failed secondary link station addresses. This object only has meaning for SDLC ports where sdlcPortOperRole == primary and sdlcPortOperTopology == multipoint | 1.3.6.1.2.1.41.1.1.2.1.10 | TimeInterval | read-only | current |
| sdlcPortOperLastModifyTime OBJECT-TYPE This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero. | 1.3.6.1.2.1.41.1.1.2.1.11 | TimeTicks | read-only | current |
| sdlcPortOperLastFailTime OBJECT-TYPE This object describes the value of sysUpTime when this SDLC port last failed. If the port has not failed, then this value shall be zero. | 1.3.6.1.2.1.41.1.1.2.1.12 | TimeTicks | read-only | current |
| sdlcPortOperLastFailCause OBJECT-TYPE This enumerated object describes the cause of the last failure of this SDLC port. If the port has not failed, then this object has a value of undefined(1). | 1.3.6.1.2.1.41.1.1.2.1.13 | INTEGER {undefined(1), physical(2)} | read-only | current |
| sdlcPortStatsTable OBJECT-TYPE Each entry in this table contains statistics for a specific SDLC port. | 1.3.6.1.2.1.41.1.1.3 | not-accessible | current | |
| sdlcPortStatsEntry OBJECT-TYPE A list of statistics for an SDLC port. | 1.3.6.1.2.1.41.1.1.3.1 | not-accessible | current | |
| sdlcPortStatsPhysicalFailures OBJECT-TYPE This object reflects the total number of times this port has failed due to its physical media since port startup. At port startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.1.3.1.1 | Counter32 | read-only | current |
| sdlcPortStatsInvalidAddresses OBJECT-TYPE This object reflects the total number of frames received by this port with invalid link station addresses. | 1.3.6.1.2.1.41.1.1.3.1.2 | Counter32 | read-only | current |
| sdlcPortStatsDwarfFrames OBJECT-TYPE This object reflects the total number of frames received by this port which were delivered intact by the physical layer but were too short to be legal. Ignoring the frame check sequence (FCS), a frame is considered to be too short if it is less than 2 bytes for sdlcLSOperMODULO of eight, or if it is less than 3 bytes for sdlcLSOperMODULO of onetwentyeight. | 1.3.6.1.2.1.41.1.1.3.1.3 | Counter32 | read-only | current |
| sdlcPortStatsPollsIn OBJECT-TYPE This object reflects the total number of polls received by this port since the port was created. | 1.3.6.1.2.1.41.1.1.3.1.4 | Counter32 | read-only | current |
| sdlcPortStatsPollsOut OBJECT-TYPE This object reflects the total number of polls sent by this port since the port was created. | 1.3.6.1.2.1.41.1.1.3.1.5 | Counter32 | read-only | current |
| sdlcPortStatsPollRspsIn OBJECT-TYPE This object reflects the total number of poll responses received by this port since the port was created. | 1.3.6.1.2.1.41.1.1.3.1.6 | Counter32 | read-only | current |
| sdlcPortStatsPollRspsOut OBJECT-TYPE This object reflects the total number of poll responses sent by this port since the port was created. | 1.3.6.1.2.1.41.1.1.3.1.7 | Counter32 | read-only | current |
| sdlcPortStatsLocalBusies OBJECT-TYPE This object reflects the total number of times that the local SDLC link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.8 | Counter32 | read-only | current |
| sdlcPortStatsRemoteBusies OBJECT-TYPE This object reflects the total number of times that the adjacent (i.e., remote) SDLC link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.9 | Counter32 | read-only | current |
| sdlcPortStatsIFramesIn OBJECT-TYPE This object reflects the total number of I-Frames that have been received by SDLC link stations on this port. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.10 | Counter32 | read-only | current |
| sdlcPortStatsIFramesOut OBJECT-TYPE This object reflects the total number of I-Frames that have been transmitted by SDLC link stations on this port. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.11 | Counter32 | read-only | current |
| sdlcPortStatsOctetsIn OBJECT-TYPE This object reflects the total octets received from adjacent SDLC link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.12 | Counter32 | read-only | current |
| sdlcPortStatsOctetsOut OBJECT-TYPE This object reflects the total octets transmitted to adjacent SDLC link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.13 | Counter32 | read-only | current |
| sdlcPortStatsProtocolErrs OBJECT-TYPE This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of having received a protocol violation from the adjacent link station. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.14 | Counter32 | read-only | current |
| sdlcPortStatsActivityTOs OBJECT-TYPE This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of no activity on the link. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.15 | Counter32 | read-only | current |
| sdlcPortStatsRNRLIMITs OBJECT-TYPE This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of its RNRLIMIT timer expiring. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.16 | Counter32 | read-only | current |
| sdlcPortStatsRetriesExps OBJECT-TYPE This object reflects the total number of times that the SDLC link stations on this port have deactivated the link as a result of a retry sequence being exhausted. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.17 | Counter32 | read-only | current |
| sdlcPortStatsRetransmitsIn OBJECT-TYPE This object reflects the total number of I-Frames retransmitted by remote link stations for all SDLC link stations on this port. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.18 | Counter32 | read-only | current |
| sdlcPortStatsRetransmitsOut OBJECT-TYPE This object reflects the total number of I-Frames retransmitted by all local SDLC link stations on this port. This object is initialized to zero when the port is created. | 1.3.6.1.2.1.41.1.1.3.1.19 | Counter32 | read-only | current |
| sdlcLSGroup OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.2 | |||
| sdlcLSAdminTable OBJECT-TYPE This table contains objects that can be changed to manage an SDLC link station. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in sdlcLSAdminTable can be created either by an agent or a management station. The management station can create an entry in sdlcLSAdminTable by setting the appropriate value in sdlcLSAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the sdlcLSOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started. | 1.3.6.1.2.1.41.1.2.1 | not-accessible | current | |
| sdlcLSAdminEntry OBJECT-TYPE A list of configured values for an SDLC link station. | 1.3.6.1.2.1.41.1.2.1.1 | not-accessible | current | |
| sdlcLSAddress OBJECT-TYPE This value is the poll address of the secondary link station for this SDLC link. It uniquely identifies the SDLC link station within a single SDLC port. | 1.3.6.1.2.1.41.1.2.1.1.1 | INTEGER (1..255) | read-create | current |
| sdlcLSAdminName OBJECT-TYPE An octet string that defines the local name of the SDLC link station. This field may be sent in the XID3 control vector 0x0E, type 0xF7. | 1.3.6.1.2.1.41.1.2.1.1.2 | DisplayString (SIZE(1..10)) | read-create | current |
| sdlcLSAdminState OBJECT-TYPE This object controls the desired state of the SDLC station. The managed system shall attempt to keep the operational state, sdlcLSOperState, consistent with this value. | 1.3.6.1.2.1.41.1.2.1.1.3 | INTEGER {inactive(1), active(2)} | read-create | current |
| sdlcLSAdminISTATUS OBJECT-TYPE This parameter controls the desired state, sdlcLSAdminState, of the SDLC link station at link station start-up. | 1.3.6.1.2.1.41.1.2.1.1.4 | INTEGER {inactive(1), active(2)} | read-create | current |
| sdlcLSAdminMAXDATASend OBJECT-TYPE This object contains the maximum PDU size that the local link station thinks it can send to the adjacent link station before having received any XID from the ALS. After the maximum PDU size that the ALS can receive is known (via XID exchange) that value is reflected in sdlcLSOperMAXDATASend and takes precedence over this object. This value includes the Transmission Header (TH) and the Request Header (RH). | 1.3.6.1.2.1.41.1.2.1.1.5 | Integer32 | read-create | current |
| sdlcLSAdminMAXDATARcv OBJECT-TYPE This object contains the maximum PDU size that the local link station can receive from the adjacent link station. This value is sent in the XID to the ALS. This value includes the Transmission Header (TH) and the Request Header (RH). | 1.3.6.1.2.1.41.1.2.1.1.6 | Integer32 | read-create | current |
| sdlcLSAdminREPLYTO OBJECT-TYPE This object controls the reply timeout (in 1/100ths of a second) for an SDLC link station. If the link station does not receive a response to a poll or message before the specified time expires then the appropriate error recovery shall be initiated. The object descriptor contains the name of an NCP configuration parameter, REPLYTO. Please note that the value of this object represents 1/100ths of a second while the NCP REPLYTO is represented in 1/10ths of a second. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperREPLYTO, until the link station is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary | 1.3.6.1.2.1.41.1.2.1.1.7 | TimeInterval | read-create | current |
| sdlcLSAdminMAXIN OBJECT-TYPE This object controls the maximum number of unacknowledged I-frames which an SDLC link station may receive. This should range from 1 to (sdlcLSAdminMODULO - 1). This value is sent in the XID to the ALS. A write operation to this administered value will not change the operational value, sdlcLSOperMAXIN, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.8 | INTEGER (1..127) | read-create | current |
| sdlcLSAdminMAXOUT OBJECT-TYPE This object controls the maximum number of consecutive unacknowledged I-frames which an SDLC link station shall send without an acknowledgement. This shall range from 1 to (sdlcLSAdminMODULO - 1). For link stations on switched SDLC lines, certain implementions may choose to override this administered value with the value received in the XID exchange. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperMAXOUT, until the link station is cycled inactive. An implementation can support only modulo 8, only modulo 128, or both. | 1.3.6.1.2.1.41.1.2.1.1.9 | INTEGER (1..127) | read-create | current |
| sdlcLSAdminMODULO OBJECT-TYPE This object controls the modulus for an SDLC link station. This modulus determines the size of the rotating acknowledgement window used the SDLC link station pair. A write operation to this administered value will not change the operational value, sdlcLSOperMODULO, until the link station is cycled inactive. An implementation can support only modulo 8, only modulo 128, or both. | 1.3.6.1.2.1.41.1.2.1.1.10 | INTEGER {eight(8), onetwentyeight(128)} | read-create | current |
| sdlcLSAdminRETRIESm OBJECT-TYPE This object controls number of retries in a retry sequence for the local SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The number of times that the retry sequence is to be repeated is controlled by the object: sdlcLSAdminRETRIESn. The interval between retry sequences is controlled by the object: sdlcLSAdminRETRIESt. A value of zero indicates no retries. If the value of sdlcLSAdminRETRIESm is zero, then the values of sdlcLSAdminRETRIESt and sdlcLSAdminRETRIESn should also be zero. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESm, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.11 | INTEGER (0..128) | read-create | current |
| sdlcLSAdminRETRIESt OBJECT-TYPE This object controls the interval (in 1/100ths of a second) between retry sequences for the local SDLC link station if multiple retry sequences are specified . A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The number of repeated retries sequences is controlled by the object: sdlcLSAdminRETRIESn. The retries per sequence is controlled by the object: sdlcLSAdminRETRIESm. The object descriptor contains the name of an NCP configuration parameter, RETRIESt. Please note that the value of this object represents 1/100ths of a second while the NCP RETRIESt is represented in seconds. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESt, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.12 | TimeInterval | read-create | current |
| sdlcLSAdminRETRIESn OBJECT-TYPE This object controls the number of times that a retry sequence is repeated for the local SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The interval between retry sequences is controlled by the object: sdlcLSAdminRETRIESn. The retries per sequence is controlled by the object: sdlcLSAdminRETRIESm. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRETRIESn, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.13 | Integer32 | read-create | current |
| sdlcLSAdminRNRLIMIT OBJECT-TYPE This object controls the length of time (in 1/100ths of a second) that an SDLC link station will allow its adjacent link station to remain in a busy (RNR) state before declaring it inoperative. A value of sdlcLSAdminRNRLIMIT == 0 means there is no limit. The object descriptor contains the name of an NCP configuration parameter, RNRLIMIT. Please note that the value of this object represents 1/100ths of a second while the NCP RNRLIMIT is represented in minutes. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperRNRLIMIT, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.14 | TimeInterval | read-create | current |
| sdlcLSAdminDATMODE OBJECT-TYPE This object controls whether communications mode with the adjacent link station is two-way-alternate (half) or two-way-simultaneous (full). A write operation to this administered value will not change the operational value, sdlcLSOperDATMODE, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.15 | INTEGER {half(1), full(2)} | read-create | current |
| sdlcLSAdminGPoll OBJECT-TYPE This object describes the group poll address for this link station instance. If group poll is not in effect for this link station instance, the value for sdlcLSAdminGPoll should be zero. Depending on the implementation, a write operation to this administered value may not change the operational value, sdlcLSOperGPoll, until the link station is cycled inactive. | 1.3.6.1.2.1.41.1.2.1.1.16 | INTEGER (0..254) | read-create | current |
| sdlcLSAdminSimRim OBJECT-TYPE This object controls the support for transmission and receipt of SIM and RIM control frames for this link station. The value of this object controls the setting of the transmit-receive capability sent in the XID field. | 1.3.6.1.2.1.41.1.2.1.1.17 | INTEGER {no(1), yes(2)} | read-create | current |
| sdlcLSAdminXmitRcvCap OBJECT-TYPE This object controls the transmit-receive capabilities for this SDLC link station. The value of this object establishes the value of the transmit-receive capability indicator sent in the XID image to the adjacent link station. | 1.3.6.1.2.1.41.1.2.1.1.18 | INTEGER {twa(1), tws(2)} | read-create | current |
| sdlcLSAdminRowStatus OBJECT-TYPE This object is used by a management station to create or delete the row entry in sdlcLSAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the sdlcLSOperTable with sdlcLSOperState equal to 'discontacted (1)'. | 1.3.6.1.2.1.41.1.2.1.1.19 | RowStatus | read-create | current |
| sdlcLSOperTable OBJECT-TYPE This table contains current SDLC link parameters. Many of these objects have corresponding objects in the sdlcLSAdminTable. | 1.3.6.1.2.1.41.1.2.2 | not-accessible | current | |
| sdlcLSOperEntry OBJECT-TYPE A list of status and control values for an SDLC link station. | 1.3.6.1.2.1.41.1.2.2.1 | not-accessible | current | |
| sdlcLSOperName OBJECT-TYPE An octet string that defines the name of the remote SDLC link station. This field is received in the XID3 control vector 0x0E, type 0xF7. | 1.3.6.1.2.1.41.1.2.2.1.1 | DisplayString (SIZE(1..10)) | read-only | current |
| sdlcLSOperRole OBJECT-TYPE This object reflects the current role that the link station is assuming. The value of sdlcLSOperRole is undefined(3) whenever the link station role has not yet been established by the mode setting command. | 1.3.6.1.2.1.41.1.2.2.1.2 | INTEGER {primary(1), secondary(2), undefined(3)} | read-only | current |
| sdlcLSOperState OBJECT-TYPE This object describes the operational state of the SDLC link station. The managed system shall attempt to keep this value consistent with the administered state, sdlcLSAdminState | 1.3.6.1.2.1.41.1.2.2.1.3 | INTEGER {discontacted(1), contactPending(2), contacted(3), discontactPending(4)} | read-only | current |
| sdlcLSOperMAXDATASend OBJECT-TYPE This object contains the actual maximum PDU size that the local link station can send to the adjacent link station. This object is established from the value received in the XID from the adjacent link station. If no XID is received, then this value is implementation dependent (for instance, it could be the value of sdlcLSAdminMAXDATASend). This value includes the Transmission Header (TH) and the Request Header (RH). | 1.3.6.1.2.1.41.1.2.2.1.4 | Integer32 | read-only | current |
| sdlcLSOperREPLYTO OBJECT-TYPE This object reflects the current reply timeout (in 1/100ths of a second) for an SDLC link station. If the link station does not receive a response to a poll or message before the specified time expires then the appropriate error recovery shall be initiated. The object descriptor contains the name of an NCP configuration parameter, REPLYTO. Please note that the value of this object represents 1/100ths of a second while the NCP REPLYTO is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortOperRole == primary | 1.3.6.1.2.1.41.1.2.2.1.5 | TimeInterval | read-only | current |
| sdlcLSOperMAXIN OBJECT-TYPE This object reflects the current maximum number of unacknowledged I-frames which an SDLC link station may receive. This shall range from 1 to (sdlcLSOperMODULO - 1). | 1.3.6.1.2.1.41.1.2.2.1.6 | INTEGER (1..127) | read-only | current |
| sdlcLSOperMAXOUT OBJECT-TYPE This object controls the maximum number of consecutive unacknowledged I-frames which an SDLC link station shall send without an acknowledgement. This shall range from 1 to (sdlcLSAdminMODULO - 1). This value may controlled by the administered MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value received during the XID exchange. | 1.3.6.1.2.1.41.1.2.2.1.7 | INTEGER (1..127) | read-only | current |
| sdlcLSOperMODULO OBJECT-TYPE This object reflects the current modulus for an SDLC link station. This modulus determines the size of rotating acknowledgement window used by the SDLC link station pair. | 1.3.6.1.2.1.41.1.2.2.1.8 | INTEGER {eight(8), onetwentyeight(128)} | read-only | current |
| sdlcLSOperRETRIESm OBJECT-TYPE This object controls number of retries in a retry sequence for an SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The current number of times that the retry sequence is to be repeated is reflected by the object: sdlcLSOperRETRIESn. The current interval between retry sequences is reflected by the object: sdlcLSOperRETRIESt. | 1.3.6.1.2.1.41.1.2.2.1.9 | INTEGER (0..128) | read-only | current |
| sdlcLSOperRETRIESt OBJECT-TYPE This object reflects the current interval (in 1/100ths of a second) between retry sequences for an SDLC link station if multiple retry sequences are specified. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The object descriptor contains the name of an NCP configuration parameter, RETRIESt. Please note that the value of this object represents 1/100ths of a second while the NCP RETRIESt is represented in seconds. The current number of repeated retries sequences is reflected by the object: sdlcLSOperRETRIESn. The current retries per sequence is reflected by the object: sdlcLSOperRETRIESm. | 1.3.6.1.2.1.41.1.2.2.1.10 | TimeInterval | read-only | current |
| sdlcLSOperRETRIESn OBJECT-TYPE This object reflects the current number of times that a retry sequence is repeated for an SDLC link station. A retry sequence is a series of retransmitted frames ( data or control) for which no positive acknowledgement is received. The current interval between retry sequences is reflected by the object: sdlcLSOperRETRIESn. The current retries per sequence is reflected by the object: sdlcLSOperRETRIESm. | 1.3.6.1.2.1.41.1.2.2.1.11 | INTEGER (0..127) | read-only | current |
| sdlcLSOperRNRLIMIT OBJECT-TYPE This object reflects the current length of time (in 1/100ths of a second) that an SDLC link station will allow its adjacent link station to remain in a busy (RNR) state before declaring it inoperative. The object descriptor contains the name of an NCP configuration parameter, RNRLIMIT. Please note that the value of this object represents 1/100ths of a second while the NCP RNRLIMIT is represented in minutes. A value of sdlcLSOperRNRLIMIT == 0 means there is no limit. | 1.3.6.1.2.1.41.1.2.2.1.12 | TimeInterval | read-only | current |
| sdlcLSOperDATMODE OBJECT-TYPE This object reflects whether the current communications mode with the adjacent link station is two-way-alternate (half) or two-way-simultaneous (full). | 1.3.6.1.2.1.41.1.2.2.1.13 | INTEGER {half(1), full(2)} | read-only | current |
| sdlcLSOperLastModifyTime OBJECT-TYPE This object describes the value of sysUpTime when this link station definition was last modified. If the link station has not been modified, then this value shall be zero. | 1.3.6.1.2.1.41.1.2.2.1.14 | TimeTicks | read-only | current |
| sdlcLSOperLastFailTime OBJECT-TYPE This object describes the value of sysUpTime when this SDLC link station last failed. If the link station has not failed, then this value shall be zero. | 1.3.6.1.2.1.41.1.2.2.1.15 | TimeTicks | read-only | current |
| sdlcLSOperLastFailCause OBJECT-TYPE This enumerated object reflects the cause of the last failure of this SDLC link station. If the link station has not failed, then this object will have a value of undefined(1). | 1.3.6.1.2.1.41.1.2.2.1.16 | INTEGER {undefined(1), rxFRMR(2), txFRMR(3), noResponse(4), protocolErr(5), noActivity(6), rnrLimit(7), retriesExpired(8)} | read-only | current |
| sdlcLSOperLastFailCtrlIn OBJECT-TYPE This object reflects the last control octet or octets (depending on modulus) received by this SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning. | 1.3.6.1.2.1.41.1.2.2.1.17 | OCTET STRING (SIZE(1..2)) | read-only | current |
| sdlcLSOperLastFailCtrlOut OBJECT-TYPE This object reflects the last control octet or octets (depending on modulus) sent by this SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning. | 1.3.6.1.2.1.41.1.2.2.1.18 | OCTET STRING (SIZE(1..2)) | read-only | current |
| sdlcLSOperLastFailFRMRInfo OBJECT-TYPE This object reflects the information field of the FRMR frame if the last failure for this SDLC link station was as a result of an invalid frame. Otherwise, this field has no meaning. | 1.3.6.1.2.1.41.1.2.2.1.19 | OCTET STRING (SIZE(3)) | read-only | current |
| sdlcLSOperLastFailREPLYTOs OBJECT-TYPE This object reflects the number of times that the REPLYTO timer had expired for an SDLC link station at the time of the last failure. If the link station has not failed, then this value has no meaning. | 1.3.6.1.2.1.41.1.2.2.1.20 | Counter32 | read-only | current |
| sdlcLSOperEcho OBJECT-TYPE This object identifies whether the echo bit is in effect for this particular link station. | 1.3.6.1.2.1.41.1.2.2.1.21 | INTEGER {no(1), yes(2)} | read-only | current |
| sdlcLSOperGPoll OBJECT-TYPE This object describes the group poll address in effect for this link station instance. | 1.3.6.1.2.1.41.1.2.2.1.22 | INTEGER (0..254) | read-only | current |
| sdlcLSOperSimRim OBJECT-TYPE This object reflects the support for transmission and receipt of SIM and RIM control frames for the adjacent link station. The value of this object is set from the XID field received from the adjacent link station. | 1.3.6.1.2.1.41.1.2.2.1.23 | INTEGER {no(1), yes(2)} | read-only | current |
| sdlcLSOperXmitRcvCap OBJECT-TYPE This object reflects the transmit-receive capabilities for the adjacent SDLC link station. The value of this object is the value of the transmit-receive capability indicator received in the XID image from the adjacent link station. | 1.3.6.1.2.1.41.1.2.2.1.24 | INTEGER {twa(1), tws(2)} | read-only | current |
| sdlcLSStatsTable OBJECT-TYPE Each entry in this table contains statistics for a specific SDLC link station. | 1.3.6.1.2.1.41.1.2.3 | not-accessible | current | |
| sdlcLSStatsEntry OBJECT-TYPE A list of statistics for an SDLC link station. | 1.3.6.1.2.1.41.1.2.3.1 | not-accessible | current | |
| sdlcLSStatsBLUsIn OBJECT-TYPE This object reflects the total basic link units (BLUs; frames) received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.1 | Counter32 | read-only | current |
| sdlcLSStatsBLUsOut OBJECT-TYPE This object reflects the total basic link units (BLUs; frames), transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.2 | Counter32 | read-only | current |
| sdlcLSStatsOctetsIn OBJECT-TYPE This object reflects the total octets received from an adjacent SDLC link station since link station startup. This object covers the address, control, and information field of I-Frames only. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.3 | Counter32 | read-only | current |
| sdlcLSStatsOctetsOut OBJECT-TYPE This object reflects the total octets transmitted to an adjacent SDLC link station since link station startup. This object covers the address, control, and information field of I-Frames only. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.4 | Counter32 | read-only | current |
| sdlcLSStatsPollsIn OBJECT-TYPE This object reflects the total polls received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.5 | Counter32 | read-only | current |
| sdlcLSStatsPollsOut OBJECT-TYPE This object reflects the total polls sent to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.6 | Counter32 | read-only | current |
| sdlcLSStatsPollRspsOut OBJECT-TYPE This object reflects the total number of poll responses sent to the adjacent SDLC link station since link station startup. This value includes I-frames that are sent in response to a poll. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.7 | Counter32 | read-only | current |
| sdlcLSStatsPollRspsIn OBJECT-TYPE This object reflects the total number of poll responses received from the adjacent SDLC link station since station startup. This value includes I-frames that are received in response to a poll. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.8 | Counter32 | read-only | current |
| sdlcLSStatsLocalBusies OBJECT-TYPE This object reflects the total number of times that the local SDLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.9 | Counter32 | read-only | current |
| sdlcLSStatsRemoteBusies OBJECT-TYPE This object reflects the total number of times that an adjacent ( remote) SDLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.10 | Counter32 | read-only | current |
| sdlcLSStatsIFramesIn OBJECT-TYPE This object reflects the total I-frames received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.11 | Counter32 | read-only | current |
| sdlcLSStatsIFramesOut OBJECT-TYPE This object reflects the total I-frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.12 | Counter32 | read-only | current |
| sdlcLSStatsUIFramesIn OBJECT-TYPE This object reflects the total UI-frames received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.13 | Counter32 | read-only | current |
| sdlcLSStatsUIFramesOut OBJECT-TYPE This object reflects the total UI-frames transmitted to an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.14 | Counter32 | read-only | current |
| sdlcLSStatsXIDsIn OBJECT-TYPE This object reflects the total XID frames received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.15 | Counter32 | read-only | current |
| sdlcLSStatsXIDsOut OBJECT-TYPE This object reflects the total XID frames transmitted to an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.16 | Counter32 | read-only | current |
| sdlcLSStatsTESTsIn OBJECT-TYPE This object reflects the total TEST frames, commands or responses, received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.17 | Counter32 | read-only | current |
| sdlcLSStatsTESTsOut OBJECT-TYPE This object reflects the total TEST frames, commands or responses, transmitted to an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.18 | Counter32 | read-only | current |
| sdlcLSStatsREJsIn OBJECT-TYPE This object reflects the total REJ frames received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.19 | Counter32 | read-only | current |
| sdlcLSStatsREJsOut OBJECT-TYPE This object reflects the total REJ frames transmitted to an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.20 | Counter32 | read-only | current |
| sdlcLSStatsFRMRsIn OBJECT-TYPE This object reflects the total frame reject (FRMR) frames received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.21 | Counter32 | read-only | current |
| sdlcLSStatsFRMRsOut OBJECT-TYPE This object reflects the total frame reject (FRMR) frames transmitted to an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.22 | Counter32 | read-only | current |
| sdlcLSStatsSIMsIn OBJECT-TYPE This object reflects the total set initialization mode (SIM) frames received from an adjacent SDLC link station since link station startup. | 1.3.6.1.2.1.41.1.2.3.1.23 | Counter32 | read-only | current |
| sdlcLSStatsSIMsOut OBJECT-TYPE This object reflects the total set initialization mode (SIM) frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.24 | Counter32 | read-only | current |
| sdlcLSStatsRIMsIn OBJECT-TYPE This object reflects the total request initialization mode (RIM) frames received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.25 | Counter32 | read-only | current |
| sdlcLSStatsRIMsOut OBJECT-TYPE This object reflects the total request initialization mode (RIM) frames transmitted to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.26 | Counter32 | read-only | current |
| sdlcLSStatsDISCIn OBJECT-TYPE This object reflects the total number of disconnect (DISC) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.27 | Counter32 | read-only | current |
| sdlcLSStatsDISCOut OBJECT-TYPE This object reflects the total number of disconnect (DISC) requests transmited to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.28 | Counter32 | read-only | current |
| sdlcLSStatsUAIn OBJECT-TYPE This object reflects the total number of unnumbered acknowledgements (UA) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.29 | Counter32 | read-only | current |
| sdlcLSStatsUAOut OBJECT-TYPE This object reflects the total number of unnumbered acknowledgements (UA) requests transmited to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.30 | Counter32 | read-only | current |
| sdlcLSStatsDMIn OBJECT-TYPE This object reflects the total number of disconnect mode (DM) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.31 | Counter32 | read-only | current |
| sdlcLSStatsDMOut OBJECT-TYPE This object reflects the total number of disconnect mode (DM) requests transmited to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.32 | Counter32 | read-only | current |
| sdlcLSStatsSNRMIn OBJECT-TYPE This object reflects the total number of set normal response mode (SNRM/SNRME) requests received from an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.33 | Counter32 | read-only | current |
| sdlcLSStatsSNRMOut OBJECT-TYPE This object reflects the total number of set normal response mode (SNRM/SNRME) requests transmited to an adjacent SDLC link station since link station startup. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.34 | Counter32 | read-only | current |
| sdlcLSStatsProtocolErrs OBJECT-TYPE This object reflects the total occurrences, since link station startup, where this SDLC link station has inactivated the link as a result of receiving a frame from its adjacent link station which was in violation of the protocol. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.35 | Counter32 | read-only | current |
| sdlcLSStatsActivityTOs OBJECT-TYPE This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of no activity on the link. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.36 | Counter32 | read-only | current |
| sdlcLSStatsRNRLIMITs OBJECT-TYPE This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of its RNRLIMIT timer expiring. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.37 | Counter32 | read-only | current |
| sdlcLSStatsRetriesExps OBJECT-TYPE This object reflects the total occurrences, since startup, where this SDLC link station has inactivated the link as a result of a retry sequence being exhausted. At link station startup time, this object must be initialized to zero. | 1.3.6.1.2.1.41.1.2.3.1.38 | Counter32 | read-only | current |
| sdlcLSStatsRetransmitsIn OBJECT-TYPE This object reflects the total number of information frames retransmitted by the remote link station because the N(s) received from that link station indicated that one or more information frames sent by that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero. Management: If the value of sdlcLSStatsRetransmitsIn grows over time, then the quality of the serial line is in question. You might want to look at decreasing the value for sdlcLSAdminMAXDATASend to compensate for the lower quality line. | 1.3.6.1.2.1.41.1.2.3.1.39 | Counter32 | read-only | current |
| sdlcLSStatsRetransmitsOut OBJECT-TYPE This object reflects the total number of information frames retransmitted to a remote link station because the N(r) received from that link station indicated that one or more information frames sent to that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero. Management: If the value of sdlcLSStatsRetransmitsOut grows over time, then the quality of the serial line is in question. You might want to look at decreasing the value for sdlcLSAdminMAXDATASend to compensate for the lower quality line. | 1.3.6.1.2.1.41.1.2.3.1.40 | Counter32 | read-only | current |
| sdlcTraps OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.3 | |||
| sdlcConformance OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.4 | |||
| sdlcCompliances OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.4.1 | |||
| sdlcGroups OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.4.2 | |||
| sdlcCoreGroups OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.4.2.1 | |||
| sdlcPrimaryGroups OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.4.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| sdlcPortStatusChange NOTIFICATION-TYPE This trap indicates that the state of an SDLC port has transitioned to active or inactive. | 1.3.6.1.2.1.41.1.3.1 | current |
| sdlcLSStatusChange NOTIFICATION-TYPE This trap indicates that the state of an SDLC link station has transitioned to contacted or discontacted. | 1.3.6.1.2.1.41.1.3.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| sdlcCoreCompliance MODULE-COMPLIANCE The core compliance statement for all SDLC nodes. | 1.3.6.1.2.1.41.1.4.1.1 | current |
| sdlcPrimaryCompliance MODULE-COMPLIANCE The compliance statement for all nodes that are performing the role of a Primary link station. | 1.3.6.1.2.1.41.1.4.1.2 | current |
| sdlcPrimaryMultipointCompliance MODULE-COMPLIANCE The compliance statement for all nodes that are performing the role of a primary link station on a multipoint line. | 1.3.6.1.2.1.41.1.4.1.3 | current |
| sdlcCorePortAdminGroup OBJECT-GROUP The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.1 | current |
| sdlcCorePortOperGroup OBJECT-GROUP The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.2 | current |
| sdlcCorePortStatsGroup OBJECT-GROUP The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.3 | current |
| sdlcCoreLSAdminGroup OBJECT-GROUP The sdlcCorePortAdminGroup defines objects which are common to the PortAdmin group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.4 | current |
| sdlcCoreLSOperGroup OBJECT-GROUP The sdlcCorePortOperGroup defines objects which are common to the PortOper group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.5 | current |
| sdlcCoreLSStatsGroup OBJECT-GROUP The sdlcCorePortStatsGroup defines objects which are common to the PortStats group of all compliant link stations. | 1.3.6.1.2.1.41.1.4.2.1.6 | current |
| sdlcPrimaryGroup OBJECT-GROUP The sdlcPrimaryGroup defines objects which are common to all compliant primary link stations. | 1.3.6.1.2.1.41.1.4.2.2.1 | current |
| sdlcPrimaryMultipointGroup OBJECT-GROUP The sdlcPrimaryMultipointGroup defines objects which are common to all compliant primary link stations that are in a multipoint topology. | 1.3.6.1.2.1.41.1.4.2.2.2 | current |