This MIB module describes the available on-demand tests.

Contact

Omri_Viner@PacketLight.com

Imports

FromSymbols
IF-MIBInterfaceIndex
PerfHist-TC-MIBPerfCurrentCount, PerfIntervalCount, PerfTotalCount
SL-MAIN-MIBslMain
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SL-MAIN-MIB
SL-NE-MIB
SL-TESTS-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
slTestsIfLoop
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.3.13.1
slTestsIfLoopTable
OBJECT-TYPE
The port loopback test table. This table controls the port loopback tests.
1.3.6.1.4.1.4515.1.3.13.1.1not-accessiblecurrent
slTestsIfLoopEntry
OBJECT-TYPE
This entry is used to operate an port loopback test.
1.3.6.1.4.1.4515.1.3.13.1.1.1not-accessiblecurrent
slTestsIfLoopIfIndex
OBJECT-TYPE
The Interface Index of the port that should be loopped back.
1.3.6.1.4.1.4515.1.3.13.1.1.1.1InterfaceIndexread-onlycurrent
slTestsIfLoopDuration
OBJECT-TYPE
The test duration in 1/10 Sec. The maximum allowed duration is 1 hour. After this time the port configuration returns to its original setting and the Agent automatically deletes the entry from the table.
1.3.6.1.4.1.4515.1.3.13.1.1.1.2INTEGERread-writecurrent
slTestsIfLoopStatus
OBJECT-TYPE
This variable is used to start or stop a loopback test. In order to start a test the NMS should set the value to start(1). If the test mode is toggle, the NMS should stop the test by setting the value to stop(2). In the case of prbs test, after the test has stopped, if the test fails the value of the status shall be fail(3).
1.3.6.1.4.1.4515.1.3.13.1.1.1.3INTEGER {start(1), stop(2), fail(3)}read-writecurrent
slTestsIfLoopType
OBJECT-TYPE
The loopback type: facility The received signal at this interface is looped back out through the corresponding transmitter in the return direction. terminal The signal that is about to be transmitted is connected to the associated incoming receiver. prbs send and recieve prbs pattern. otnPrbs send and receive OTN prbs
1.3.6.1.4.1.4515.1.3.13.1.1.1.5INTEGER {terminal(1), facility(2), prbs(3), otnPrbs(4)}read-writecurrent
slTestsIfLoopMode
OBJECT-TYPE
The loopback mode: timeout In this mode the duration of the loopback is determined by the slTestsIfLoopDuration object. toggle In this mode the loopback should be toggled explicitly by the user.
1.3.6.1.4.1.4515.1.3.13.1.1.1.6INTEGER {timeout(1), toggle(2)}read-writecurrent
slTestsIfLoopErrors
OBJECT-TYPE
The prbs errors are counted only of the test succeeded.
1.3.6.1.4.1.4515.1.3.13.1.1.1.7Counter32read-onlycurrent
slTestsIfLoopResult
OBJECT-TYPE
This variable is used for prbs test result indication.
1.3.6.1.4.1.4515.1.3.13.1.1.1.8INTEGER {success(1), fail(2)}read-onlycurrent
slTestsIfLoopPassedSeconds
OBJECT-TYPE
Number of seconds passed since the test started.
1.3.6.1.4.1.4515.1.3.13.1.1.1.9INTEGERread-onlycurrent
slTestsTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.3.13.2
slTestsTraps0
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.3.13.2.0
slTestsTrapsLoopbackActive
OBJECT-TYPE
The Loopback is active Yes/No.
1.3.6.1.4.1.4515.1.3.13.2.1TruthValueread-onlycurrent

Notifications

NameOIDStatus
slTestsTrapsLoopbackTableChanged0
NOTIFICATION-TYPE
A slTestsTrapsLoopbackTableChanged trap is sent when the content of slTestsIfLoopTable changes. When the loop back is deleted the returned value of slTestsIfLoopActivity should be false.
1.3.6.1.4.1.4515.1.3.13.2.0.2current
slTestsTrapsLoopbackTableChanged
NOTIFICATION-TYPE
A slTestsTrapsLoopbackTableChanged trap is sent when the content of slTestsIfLoopTable changes. When the loop back is deleted the returned value of slTestsIfLoopActivity should be false.
1.3.6.1.4.1.4515.1.3.13.2.2current