SL-SONET-SUP-PM-MIB
- Registered at
- 1.3.6.1.4.1.4515.1.6.3
- Last updated
- 1998-07-13 17:52
- Organization
- Argon Networks, Inc.
- Namespace
- packetlight
- Source file
SL-SONET-SUP-PM-MIB- Digest
sha256:a4b338ee728602ffa3261b34cf9c0cdadae4e464d3f4cf6e4030ba7788dd8cb7
Description
This MIB module provides extensions to the SONET-MIB (RFC 2558) objects. It provides definitions for management information that supports those parts of ANSI T1.231-1997 that are not covered by the SONET-MIB.
Contact
Ken Chapman Postal: Argon Networks, Inc. 25 Porter Road Littleton, MA 01460 USA Phone: +1 978 486 0665 Fax: +1 978 486 9379 Email: KChapman@Argon.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex |
| PerfHist-TC-MIB | PerfCurrentCount, PerfIntervalCount, PerfTotalCount |
| SL-SONET-MIB | slSonetMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue |
| SONET-MIB | sonetFarEndLineCurrentEntry, sonetFarEndLineIntervalEntry, sonetFarEndPathCurrentEntry, sonetFarEndPathIntervalEntry, sonetFarEndVTCurrentEntry, sonetFarEndVTIntervalEntry, sonetLineCurrentEntry, sonetLineIntervalEntry, sonetMediumEntry, sonetPathCurrentEntry, sonetPathIntervalEntry, sonetSectionCurrentEntry, sonetSectionIntervalEntry, sonetVTCurrentEntry, sonetVTIntervalEntry |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB PerfHist-TC-MIB SL-NE-MIB SL-SONET-MIB SL-SONET-SUP-PM-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC SONET-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sonetSupObjects OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1 | |||
| sonetSupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.1 | |||
| sonetSupMedium OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.2 | |||
| sonetSupSection OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.3 | |||
| sonetSectionDefaultThresholdTable OBJECT-TYPE The table of default thresholds for SONET section counters. | 1.3.6.1.4.1.4515.1.6.3.1.3.1 | not-accessible | current | |
| sonetSectionDefaultThresholdEntry OBJECT-TYPE An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses an index to indetify the digital signal rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1 | not-accessible | current | |
| sonetSectionDefaultThresholdRate OBJECT-TYPE The digital signal rate for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.1 | INTEGER {oc1(1), oc3(2), oc12(3), oc24(4), oc48(5), oc192(6)} | read-only | current |
| sonetSectionDefaultCVThreshold OBJECT-TYPE The default value for SONET CV-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.2 | INTEGER | read-write | current |
| sonetSectionDefaultESThreshold OBJECT-TYPE The default value for SONET ES-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.3 | INTEGER | read-write | current |
| sonetSectionDefaultSESThreshold OBJECT-TYPE The default value for SONET SES-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.6 | INTEGER | read-write | current |
| sonetSectionDefaultSEFSThreshold OBJECT-TYPE The default value for SONET SEFS-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.7 | INTEGER | read-write | current |
| sonetSectionDefaultDayCVThreshold OBJECT-TYPE The default value for SONET CV-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.8 | INTEGER | read-write | current |
| sonetSectionDefaultDayESThreshold OBJECT-TYPE The default value for SONET ES-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.9 | INTEGER | read-write | current |
| sonetSectionDefaultDaySESThreshold OBJECT-TYPE The default value for SONET SES-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.12 | INTEGER | read-write | current |
| sonetSectionDefaultDaySEFSThreshold OBJECT-TYPE The default value for SONET SEFS-S counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.13 | INTEGER | read-write | current |
| sonetSectionThresholdTable OBJECT-TYPE The table of trap threshold values for SONET section counters. | 1.3.6.1.4.1.4515.1.6.3.1.3.2 | not-accessible | current | |
| sonetSectionThresholdEntry OBJECT-TYPE An entry in the table of SONET Section trap thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1 | not-accessible | current | |
| sonetSectionCurrentCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval CV-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.1 | INTEGER | read-write | current |
| sonetSectionCurrentESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval ES-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.2 | INTEGER | read-write | current |
| sonetSectionCurrentSESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval SES-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.5 | INTEGER | read-write | current |
| sonetSectionCurrentSEFSThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval SEFS-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.6 | INTEGER | read-write | current |
| sonetSectionDayCVThreshold OBJECT-TYPE The trap threshold value for the interface's current day CV-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.7 | INTEGER | read-write | current |
| sonetSectionDayESThreshold OBJECT-TYPE The trap threshold value for the interface's current day ES-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.8 | INTEGER | read-write | current |
| sonetSectionDaySESThreshold OBJECT-TYPE The trap threshold value for the interface's current day SES-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.11 | INTEGER | read-write | current |
| sonetSectionDaySEFSThreshold OBJECT-TYPE The trap threshold value for the interface's current day SEFS-S counter. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.12 | INTEGER | read-write | current |
| sonetSectionDayTable OBJECT-TYPE The SONET Section Day table. Contains various statistics collected by each SONET Section over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.1.3.15 | not-accessible | current | |
| sonetSectionDayEntry OBJECT-TYPE An entry in the SONET Section Day table. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1 | not-accessible | current | |
| sonetSectionDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of section related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.1 | INTEGER (0..33) | read-only | current |
| sonetSectionDayStartTime OBJECT-TYPE This variable indicates the date and time at which this 1-day interval of sections measurements began on this interface. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.2 | DateAndTime | read-only | current |
| sonetSectionDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.3 | TruthValue | read-only | current |
| sonetSectionDayCVs OBJECT-TYPE The section code violation (CV-S) count is the number of BIP-8 errors which were detected at the SONET section layer interface in a previous 1-day interval. Each section BIP-8 can detect up to eight errors per STS-N frame, with each error incrementing the CV counter. CVs for the section layer are collected using the BIP-8 in the B1 byte located in the section overhead of STS-1 number 1. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.4 | PerfTotalCount | read-only | current |
| sonetSectionDayESs OBJECT-TYPE The section errored second (ES-S) count is the number of 1-second intervals containing one or more BIP-8 error (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.5 | PerfTotalCount | read-only | current |
| sonetSectionDaySESs OBJECT-TYPE The section severely errored second (SES-S) count is the number of 1-second intervals containing sonetSevereErrorThreshold or more BIP-8 errors (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.8 | PerfTotalCount | read-only | current |
| sonetSectionDaySEFSs OBJECT-TYPE The section severely errored frame second (SEFS-S) count is the number of 1-second intervals containing one or more SEF defects which were encountered by the SONET section layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.9 | PerfTotalCount | read-only | current |
| sonetSectionDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.10 | TruthValue | read-only | current |
| sonetSectionDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.11 | INTEGER | read-write | current |
| sonetSupLine OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.4 | |||
| sonetLineDefaultThresholdTable OBJECT-TYPE The table of default thresholds for SONET Line counters. | 1.3.6.1.4.1.4515.1.6.3.1.4.1 | not-accessible | current | |
| sonetLineDefaultThresholdEntry OBJECT-TYPE An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1 | not-accessible | current | |
| sonetLineDefaultThresholdDirection OBJECT-TYPE The digital signal direction for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.1 | INTEGER {nearEnd(1), farEnd(2)} | read-only | current |
| sonetLineDefaultThresholdRate OBJECT-TYPE The digital signal rate for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.2 | INTEGER {vt1dot5(1), vtg(2), oc1(3), oc3(4), oc12(5), oc24(6), oc48(7), oc192(8)} | read-only | current |
| sonetLineDefaultCVThreshold OBJECT-TYPE The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.3 | INTEGER | read-write | current |
| sonetLineDefaultESThreshold OBJECT-TYPE The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.4 | INTEGER | read-write | current |
| sonetLineDefaultSESThreshold OBJECT-TYPE The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.7 | INTEGER | read-write | current |
| sonetLineDefaultUASThreshold OBJECT-TYPE The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.9 | INTEGER | read-write | current |
| sonetLineDefaultDayCVThreshold OBJECT-TYPE The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.10 | INTEGER | read-write | current |
| sonetLineDefaultDayESThreshold OBJECT-TYPE The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.11 | INTEGER | read-write | current |
| sonetLineDefaultDaySESThreshold OBJECT-TYPE The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.14 | INTEGER | read-write | current |
| sonetLineDefaultDayUASThreshold OBJECT-TYPE The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.16 | INTEGER | read-write | current |
| sonetLineThresholdTable OBJECT-TYPE The table of trap threshold values for SONET Line counters. | 1.3.6.1.4.1.4515.1.6.3.1.4.2 | not-accessible | current | |
| sonetLineThresholdEntry OBJECT-TYPE An entry in the table of SONET Line trap thresholds. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1 | not-accessible | current | |
| sonetLineThresholdDirection OBJECT-TYPE The digital signal direction for which the threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.1 | INTEGER {nearEnd(1), farEnd(2)} | read-only | current |
| sonetLineCurrentCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.2 | INTEGER | read-write | current |
| sonetLineCurrentESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.3 | INTEGER | read-write | current |
| sonetLineCurrentSESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.4 | INTEGER | read-write | current |
| sonetLineCurrentUASThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.5 | INTEGER | read-write | current |
| sonetLineDayCVThreshold OBJECT-TYPE The trap threshold value for the interface's current day CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.6 | INTEGER | read-write | current |
| sonetLineDayESThreshold OBJECT-TYPE The trap threshold value for the interface's current day ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.7 | INTEGER | read-write | current |
| sonetLineDaySESThreshold OBJECT-TYPE The trap threshold value for the interface's current day SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.8 | INTEGER (0..65535) | read-write | current |
| sonetLineDayUASThreshold OBJECT-TYPE The trap threshold value for the interface's current day UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.9 | INTEGER | read-write | current |
| sonetLineDayTable OBJECT-TYPE The SONET Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.1.4.5 | not-accessible | current | |
| sonetLineDayEntry OBJECT-TYPE An entry in the SONET Line Day table. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1 | not-accessible | current | |
| sonetLineDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of near-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.1 | INTEGER (0..33) | read-only | current |
| sonetLineDayStartTime OBJECT-TYPE This variable indicates the date and time at which this 1-day interval of near-end line measurements began on this interface. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.2 | DateAndTime | read-only | current |
| sonetLineDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.3 | TruthValue | read-only | current |
| sonetLineDayCVs OBJECT-TYPE The line code violation (CV-L) count is the number of BIP-8 errors which were detected at the SONET line layer interface in a previous 1-day interval. Each line BIP-8 can detect up to eight errors per STS-1 frame, with each error incrementing the CV counter. CVs for the line layer are collected using the BIP-8s in the B2 byte located in the line overhead of STS-1. (Since all CVs on an STS-N line are counted together, this is equivalent to counting each error in the BIP-8N contained in the B2 bytes of the STS-N line overhead.) Thus, on an STS-N signal, up to 8 x N CVs may occure in each STS-N frame. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.5 | PerfTotalCount | read-only | current |
| sonetLineDayESs OBJECT-TYPE The line errored second (ES-L) count is the number of 1-second intervals containing one or more EDC error (B2 byte), or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.6 | PerfTotalCount | read-only | current |
| sonetLineDaySESs OBJECT-TYPE The line severely errored second (SES-L) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC errors (B2 byte) or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.9 | PerfTotalCount | read-only | current |
| sonetLineDayUASs OBJECT-TYPE The line unavailable second (UAS-L) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-Ls. The 10 SES-Ls are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-Ls. The 10 seconds with no SES-Ls are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.10 | PerfTotalCount | read-only | current |
| sonetLineDayPSC OBJECT-TYPE The number of protection switching occured. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.11 | PerfTotalCount | read-only | current |
| sonetLineDayPSD OBJECT-TYPE The length of time in seconds, where the protection unit was in service and the working unit was out of service, during the day. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.12 | PerfTotalCount | read-only | current |
| sonetLineDayFCs OBJECT-TYPE The number of failure counts occured during the day. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.13 | PerfTotalCount | read-only | current |
| sonetLineDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.14 | TruthValue | read-only | current |
| sonetLineDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.15 | INTEGER | read-write | current |
| sonetSupFarEndLine OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.5 | |||
| sonetFarEndLineDayTable OBJECT-TYPE The SONET Far End Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.1.5.3 | not-accessible | current | |
| sonetFarEndLineDayEntry OBJECT-TYPE An entry in the SONET Far End Line Day table. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1 | not-accessible | current | |
| sonetFarEndLineDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of far-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.1 | INTEGER (1..33) | read-only | current |
| sonetFarEndLineDayStartTime OBJECT-TYPE This variable indicates the date and time at which this 1-day interval of far-end line measurements began on this interface. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.2 | DateAndTime | read-only | current |
| sonetFarEndLineDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected). | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.3 | TruthValue | read-only | current |
| sonetFarEndLineDayCVs OBJECT-TYPE The far-end line code violation (CV-LFE) count is the number of REI-Ls which were detected at the SONET line layer interface in a previous 1-day interval. For EC-1 or OC-1, REI-L is bits 5 to 8 of the M0 byte; for EC-N or OC-N (N>2), M1 byte. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.5 | PerfTotalCount | read-only | current |
| sonetFarEndLineDayESs OBJECT-TYPE The far-end line errored second (ES-LFE) count is the number of 1-second intervals containing one or more REDC-Ls, or one or more RDI-L defects which were encountered by the SONET line layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.6 | PerfTotalCount | read-only | current |
| sonetFarEndLineDaySESs OBJECT-TYPE The far-end line severely errored second (SES-LFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ls or one or more RDI-L defects which were detected by the SONET line layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.9 | PerfTotalCount | read-only | current |
| sonetFarEndLineDayUASs OBJECT-TYPE The far-end line unavailable second (UAS-LFE) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-LEFs. The 10 SES-LEFs are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-LEFs. The 10 seconds with no SES-LEFs are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.10 | PerfTotalCount | read-only | current |
| sonetFarEndLineDayFCs OBJECT-TYPE The far-end line failures count. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.11 | PerfTotalCount | read-only | current |
| sonetFarEndLineDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.12 | TruthValue | read-only | current |
| sonetFarEndLineDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.13 | INTEGER | read-write | current |
| sonetTrap OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.1.6 | |||
| sonetCounterId OBJECT-TYPE The OBJECT IDENTIFIER of the instance of the SONET counter that has crossed its threshold. | 1.3.6.1.4.1.4515.1.6.3.1.6.1 | OBJECT IDENTIFIER | accessible-for-notify | current |
| sonetCounterValue OBJECT-TYPE The current value of the SONET counter that has crossed its threshold. | 1.3.6.1.4.1.4515.1.6.3.1.6.2 | Integer32 | accessible-for-notify | current |
| sonetSupObjectsPath OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.2 | |||
| sonetSupPath OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.2.1 | |||
| sonetPathDefaultThresholdTable OBJECT-TYPE The table of default thresholds for SONET Path counters. | 1.3.6.1.4.1.4515.1.6.3.2.1.1 | not-accessible | current | |
| sonetPathDefaultThresholdEntry OBJECT-TYPE An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1 | not-accessible | current | |
| sonetPathDefaultThresholdDirection OBJECT-TYPE The digital signal direction for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.1 | INTEGER {nearEnd(1), farEnd(2)} | read-only | current |
| sonetPathDefaultThresholdRate OBJECT-TYPE The path digital signal rate for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.2 | INTEGER {sts1(1), sts3(2), sts12(3), sts24(4), sts48(5), sts192(6)} | read-only | current |
| sonetPathDefaultCVThreshold OBJECT-TYPE The default value for SONET CV-P and CV-PFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.3 | INTEGER | read-write | current |
| sonetPathDefaultESThreshold OBJECT-TYPE The default value for SONET ES-P and ES-PFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.4 | INTEGER | read-write | current |
| sonetPathDefaultSESThreshold OBJECT-TYPE The default value for SONET SES-P and SES-PFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.7 | INTEGER | read-write | current |
| sonetPathDefaultUASThreshold OBJECT-TYPE The default value for SONET UAS-P and UAS-PFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.8 | INTEGER | read-write | current |
| sonetPathDefaultDayCVThreshold OBJECT-TYPE The default value for SONET CV-P and CV-PFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.16 | INTEGER | read-write | current |
| sonetPathDefaultDayESThreshold OBJECT-TYPE The default value for SONET ES-P and ES-PFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.17 | INTEGER | read-write | current |
| sonetPathDefaultDaySESThreshold OBJECT-TYPE The default value for SONET SES-P and SES-PFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.20 | INTEGER | read-write | current |
| sonetPathDefaultDayUASThreshold OBJECT-TYPE The default value for SONET UAS-P and UAS-PFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.21 | INTEGER | read-write | current |
| sonetPathThresholdTable OBJECT-TYPE The table of trap threshold values for SONET Path counters. | 1.3.6.1.4.1.4515.1.6.3.2.1.2 | not-accessible | current | |
| sonetPathThresholdEntry OBJECT-TYPE An entry in the table of SONET Path trap thresholds. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1 | not-accessible | current | |
| sonetPathThresholdDirection OBJECT-TYPE The digital signal direction for which the threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.1 | INTEGER {nearEnd(1), farEnd(2)} | read-only | current |
| sonetPathCurrentCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.2 | INTEGER | read-write | current |
| sonetPathCurrentESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.3 | INTEGER | read-write | current |
| sonetPathCurrentSESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.4 | INTEGER | read-write | current |
| sonetPathCurrentUASThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.5 | INTEGER | read-write | current |
| sonetPathDayCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.6 | INTEGER | read-write | current |
| sonetPathDayESThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.7 | INTEGER | read-write | current |
| sonetPathDaySESThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.8 | INTEGER | read-write | current |
| sonetPathDayUASThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.9 | INTEGER | read-write | current |
| sonetPathDayTable OBJECT-TYPE The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.2.1.17 | not-accessible | current | |
| sonetPathDayEntry OBJECT-TYPE An entry in the SONET Path Day table. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1 | not-accessible | current | |
| sonetPathDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.1 | INTEGER (1..33) | read-only | current |
| sonetPathDayStartTime OBJECT-TYPE This variable indicates the date and time at which the 1-day interval of measurements began on this interface. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.2 | DateAndTime | read-only | current |
| sonetPathDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.3 | TruthValue | read-only | current |
| sonetPathDayCVs OBJECT-TYPE The path code violation (CV-P) count is the number of BIP-8 errors which were detected at the STS-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-8 in the B3 byte located in the STS-path overhead. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.5 | PerfTotalCount | read-only | current |
| sonetPathDayESs OBJECT-TYPE The path errored second (ES-P) count is the number of 1-second intervals containing one or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.6 | PerfTotalCount | read-only | current |
| sonetPathDaySESs OBJECT-TYPE The path severely errored second (SES-P) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.9 | PerfTotalCount | read-only | current |
| sonetPathDayUASs OBJECT-TYPE The path unavailable second (UAS-P) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-Ps. The 10 SES-Ps are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-Ps. The 10 seconds with no SES-Ps are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.10 | PerfTotalCount | read-only | current |
| sonetPathDayFCs OBJECT-TYPE The number path failures count during a day. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.11 | PerfTotalCount | read-only | current |
| sonetPathDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.12 | TruthValue | read-only | current |
| sonetPathDayEBs OBJECT-TYPE The number path blocks in which one or more bits are in error counted during a day. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.13 | PerfTotalCount | read-only | current |
| sonetPathDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.14 | INTEGER | read-write | current |
| sonetSupFarEndPath OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.2.2 | |||
| sonetFarEndPathDayTable OBJECT-TYPE The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.2.2.3 | not-accessible | current | |
| sonetFarEndPathDayEntry OBJECT-TYPE An entry in the SONET Far End Path Day table. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1 | not-accessible | current | |
| sonetFarEndPathDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of far-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.1 | INTEGER (1..4) | read-only | current |
| sonetFarEndPathDayStartTime OBJECT-TYPE This variable indicates the date and time at which the current interval of measurements began. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.2 | DateAndTime | read-only | current |
| sonetFarEndPathDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected). | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.3 | TruthValue | read-only | current |
| sonetFarEndPathDayCVs OBJECT-TYPE The far-end path code violation (CV-PFE) count is the number of REI-Ps (bit 1-4 in G1 byte) which were detected at the SONET STS-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.5 | PerfTotalCount | read-only | current |
| sonetFarEndPathDayESs OBJECT-TYPE The far-end path errored second (ES-PFE) count is the number of 1-second intervals containing one or more REDC-P, or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were encountered by the SONET STS-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.6 | PerfTotalCount | read-only | current |
| sonetFarEndPathDaySESs OBJECT-TYPE The far-end path severely errored second (SES-PFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ps or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were detected by the SONET STS-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.9 | PerfTotalCount | read-only | current |
| sonetFarEndPathDayUASs OBJECT-TYPE The far-end path unavailable second (UAS-PFE) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-PFEs. The 10 SES-PFEs are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-PFEs. The 10 seconds with no SES-PFEs are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.10 | PerfTotalCount | read-only | current |
| sonetFarEndPathDayFCs OBJECT-TYPE The far-end path failures count. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.11 | PerfTotalCount | read-only | current |
| sonetFarEndPathDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.12 | TruthValue | read-only | current |
| sonetFarEndPathDayEBs OBJECT-TYPE The count of far-end path blocks in which one or more bits are in error. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.13 | PerfTotalCount | read-only | current |
| sonetFarEndPathDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.14 | INTEGER | read-write | current |
| sonetSupObjectsVT OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.3 | |||
| sonetSupVT OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.3.1 | |||
| sonetVTDefaultThresholdTable OBJECT-TYPE The table of default thresholds for SONET Path counters. | 1.3.6.1.4.1.4515.1.6.3.3.1.1 | not-accessible | current | |
| sonetVTDefaultThresholdEntry OBJECT-TYPE An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1 | not-accessible | current | |
| sonetVTDefaultThresholdDirection OBJECT-TYPE The digital signal direction for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.1 | INTEGER {nearEnd(1), farEnd(2)} | not-accessible | current |
| sonetVTDefaultThresholdRate OBJECT-TYPE The path digital signal rate for which the default threshold values apply. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.2 | INTEGER {vt1dot5(1), vtg(2)} | not-accessible | current |
| sonetVTDefaultCVThreshold OBJECT-TYPE The default value for SONET CV-V and CV-VFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.3 | INTEGER (1..16383) | read-write | current |
| sonetVTDefaultESThreshold OBJECT-TYPE The default value for SONET ES-V and ES-VFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.4 | INTEGER (1..900) | read-write | current |
| sonetVTDefaultSESThreshold OBJECT-TYPE The default value for SONET SES-V and SES-VFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.5 | INTEGER (1..900) | read-write | current |
| sonetVTDefaultUASThreshold OBJECT-TYPE The default value for SONET UAS-V and UAS-VFE counter 15-minute interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.6 | INTEGER (1..900) | read-write | current |
| sonetVTDefaultDayCVThreshold OBJECT-TYPE The default value for SONET CV-V and CV-VFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.7 | INTEGER (1..1048575) | read-write | current |
| sonetVTDefaultDayESThreshold OBJECT-TYPE The default value for SONET ES-V and ES-VFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.8 | INTEGER (1..65535) | read-write | current |
| sonetVTDefaultDaySESThreshold OBJECT-TYPE The default value for SONET SES-V and SES-VFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.9 | INTEGER (1..4095) | read-write | current |
| sonetVTDefaultDayUASThreshold OBJECT-TYPE The default value for SONET UAS-V and UAS-VFE counter 1-day interval thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.10 | INTEGER (1..4095) | read-write | current |
| sonetVTThresholdTable OBJECT-TYPE The table of trap threshold values for SONET Path counters. | 1.3.6.1.4.1.4515.1.6.3.3.1.2 | not-accessible | current | |
| sonetVTThresholdEntry OBJECT-TYPE An entry in the table of SONET Path trap thresholds. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1 | not-accessible | current | |
| sonetVTCurrentCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.1 | INTEGER (0..900) | read-write | current |
| sonetVTCurrentESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.2 | INTEGER (0..900) | read-write | current |
| sonetVTCurrentSESThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.3 | INTEGER (0..900) | read-write | current |
| sonetVTCurrentUASThreshold OBJECT-TYPE The trap threshold value for the interface's current 15-minute interval UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.4 | INTEGER (0..900) | read-write | current |
| sonetVTDayCVThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.5 | INTEGER (0..65535) | read-write | current |
| sonetVTDayESThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.6 | INTEGER (0..65535) | read-write | current |
| sonetVTDaySESThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.7 | INTEGER (0..65535) | read-write | current |
| sonetVTDayUASThreshold OBJECT-TYPE The trap threshold value for the interface's current 1-day UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used. | 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.8 | INTEGER (0..65535) | read-write | current |
| sonetVTDayTable OBJECT-TYPE The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.3.1.17 | not-accessible | current | |
| sonetVTDayEntry OBJECT-TYPE An entry in the SONET Path Day table. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1 | not-accessible | current | |
| sonetVTDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.1 | INTEGER (1..33) | read-only | current |
| sonetVTDayStartTime OBJECT-TYPE This variable indicates the date and time at which the 1-day interval of measurements began on this interface. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.2 | DateAndTime | read-only | current |
| sonetVTDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.3 | TruthValue | read-only | current |
| sonetVTDayFCs OBJECT-TYPE The near-end path failure count (FC-V) is the number of occurences of near-end path failure events encountered by the SONET path layer interface in a previous 1-day interval. A near-end path failure event begins when the first of any of LOP-V, AIS-V or UNEQ-V failures is declared; a near-end path failure event ends when all LOP-V, AIS-V and UNEQ-V failures have cleared. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.4 | PerfTotalCount | read-only | current |
| sonetVTDayCVs OBJECT-TYPE The path code violation (CV-V) count is the number of BIP-2 errors which were detected at the VT-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-2 in the V5 byte located in the VT-path overhead. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.5 | PerfTotalCount | read-only | current |
| sonetVTDayESs OBJECT-TYPE The path errored second (ES-V) count is the number of 1-second intervals containing one or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.6 | PerfTotalCount | read-only | current |
| sonetVTDaySESs OBJECT-TYPE The path severely errored second (SES-V) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.7 | PerfTotalCount | read-only | current |
| sonetVTDayUASs OBJECT-TYPE The path unavailable second (UAS-V) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-Vs. The 10 SES-Vs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-Vs. The 10 seconds with no SES-Vs are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.8 | PerfTotalCount | read-only | current |
| sonetVTDayEBs OBJECT-TYPE The number VT path blocks in which one or more bits are in error counted during a day. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.9 | PerfTotalCount | read-only | current |
| sonetVTDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.10 | TruthValue | read-only | current |
| sonetVTDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.11 | INTEGER | read-write | current |
| sonetSupFarEndVT OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.6.3.3.2 | |||
| sonetFarEndVTDayTable OBJECT-TYPE The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation. | 1.3.6.1.4.1.4515.1.6.3.3.2.3 | not-accessible | current | |
| sonetFarEndVTDayEntry OBJECT-TYPE An entry in the SONET Far End Path Day table. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1 | not-accessible | current | |
| sonetFarEndVTDayNumber OBJECT-TYPE A number which identifies the 1-day interval for which the set of far-end VT-path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.1 | INTEGER (1..4) | read-only | current |
| sonetFarEndVTDayStartTime OBJECT-TYPE This variable indicates the date and time at which the current interval of measurements began. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.2 | DateAndTime | read-only | current |
| sonetFarEndVTDayValidData OBJECT-TYPE This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected). | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.3 | TruthValue | read-only | current |
| sonetFarEndVTDayFCs OBJECT-TYPE The far-end path failure count (FC-VFE) is the number of occurences of far-end path failure events detected by the SONET VT-path layer interface in a previous 1-day interval. A far-end path failure event begins when the first of any remote failure indication (RFI-V, RFI-V server, or RFI-V connectivity) failure is declared; a far-end path failure event ends when all RFI-V, RFI-V server, or RFI-V connectivity failures are cleared. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4 | PerfTotalCount | read-only | current |
| sonetFarEndVTDayCVs OBJECT-TYPE The far-end path code violation (CV-VFE) count is the number of REI-Vs (bit 1-4 in G1 byte) which were detected at the SONET VT-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.5 | PerfTotalCount | read-only | current |
| sonetFarEndVTDayESs OBJECT-TYPE The far-end path errored second (ES-VFE) count is the number of 1-second intervals containing one or more REDC-V, or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were encountered by the SONET VT-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.6 | PerfTotalCount | read-only | current |
| sonetFarEndVTDaySESs OBJECT-TYPE The far-end path severely errored second (SES-VFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Vs or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were detected by the SONET VT-path layer interface in a previous 1-day interval. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.7 | PerfTotalCount | read-only | current |
| sonetFarEndVTDayUASs OBJECT-TYPE The far-end path unavailable second (UAS-VFE) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-VFEs. The 10 SES-VFEs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-VFEs. The 10 seconds with no SES-VFEs are excluded from unavailable time. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.8 | PerfTotalCount | read-only | current |
| sonetFarEndVTDayEBs OBJECT-TYPE The number VT path blocks in which one or more bits are in error counted during a day detected by the Far End. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.9 | PerfTotalCount | read-only | current |
| sonetFarEndVTDayTcaFlag OBJECT-TYPE TRUE if one of the counters crossed the threshold during the day. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.10 | TruthValue | read-only | current |
| sonetFarEndVTDayReset OBJECT-TYPE Writing this object reset the PM counters of this interval. | 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.11 | INTEGER | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| sonetThresholdCrossing NOTIFICATION-TYPE This notification signifies that a counter has crossed its designated threshold. The term 'threshold crossing' means that a threshold has been reached or exceeded. A threshold crossing alert message (trap) signifies a performance degredation at or above the preset threshold value. | 1.3.6.1.4.1.4515.1.6.3.1.6.3 | current |