MIBs Depot

SL-SONET-SUP-PM-MIB

Registered at
1.3.6.1.4.1.4515.1.6.3
Last updated
1998-07-13 17:52
Organization
Argon Networks, Inc.
Namespace
packetlight
Source file
SL-SONET-SUP-PM-MIB
Digest
sha256:a4b338ee728602ffa3261b34cf9c0cdadae4e464d3f4cf6e4030ba7788dd8cb7

Description

This MIB module provides extensions to the SONET-MIB (RFC 2558) objects. It provides definitions for management information that supports those parts of ANSI T1.231-1997 that are not covered by the SONET-MIB.

Contact

Ken Chapman Postal: Argon Networks, Inc. 25 Porter Road Littleton, MA 01460 USA Phone: +1 978 486 0665 Fax: +1 978 486 9379 Email: KChapman@Argon.com

Imports

FromSymbols
IF-MIBifIndex
PerfHist-TC-MIBPerfCurrentCount, PerfIntervalCount, PerfTotalCount
SL-SONET-MIBslSonetMib
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue
SONET-MIBsonetFarEndLineCurrentEntry, sonetFarEndLineIntervalEntry, sonetFarEndPathCurrentEntry, sonetFarEndPathIntervalEntry, sonetFarEndVTCurrentEntry, sonetFarEndVTIntervalEntry, sonetLineCurrentEntry, sonetLineIntervalEntry, sonetMediumEntry, sonetPathCurrentEntry, sonetPathIntervalEntry, sonetSectionCurrentEntry, sonetSectionIntervalEntry, sonetVTCurrentEntry, sonetVTIntervalEntry

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SL-NE-MIB
SL-SONET-MIB
SL-SONET-SUP-PM-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
SONET-MIB

Objects

NameOIDSyntaxAccessStatus
sonetSupObjects
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1
sonetSupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.1
sonetSupMedium
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.2
sonetSupSection
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.3
sonetSectionDefaultThresholdTable
OBJECT-TYPE
The table of default thresholds for SONET section counters.
1.3.6.1.4.1.4515.1.6.3.1.3.1not-accessiblecurrent
sonetSectionDefaultThresholdEntry
OBJECT-TYPE
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses an index to indetify the digital signal rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1not-accessiblecurrent
sonetSectionDefaultThresholdRate
OBJECT-TYPE
The digital signal rate for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.1INTEGER {oc1(1), oc3(2), oc12(3), oc24(4), oc48(5), oc192(6)}read-onlycurrent
sonetSectionDefaultCVThreshold
OBJECT-TYPE
The default value for SONET CV-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.2INTEGERread-writecurrent
sonetSectionDefaultESThreshold
OBJECT-TYPE
The default value for SONET ES-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.3INTEGERread-writecurrent
sonetSectionDefaultSESThreshold
OBJECT-TYPE
The default value for SONET SES-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.6INTEGERread-writecurrent
sonetSectionDefaultSEFSThreshold
OBJECT-TYPE
The default value for SONET SEFS-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.7INTEGERread-writecurrent
sonetSectionDefaultDayCVThreshold
OBJECT-TYPE
The default value for SONET CV-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.8INTEGERread-writecurrent
sonetSectionDefaultDayESThreshold
OBJECT-TYPE
The default value for SONET ES-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.9INTEGERread-writecurrent
sonetSectionDefaultDaySESThreshold
OBJECT-TYPE
The default value for SONET SES-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.12INTEGERread-writecurrent
sonetSectionDefaultDaySEFSThreshold
OBJECT-TYPE
The default value for SONET SEFS-S counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.1.1.13INTEGERread-writecurrent
sonetSectionThresholdTable
OBJECT-TYPE
The table of trap threshold values for SONET section counters.
1.3.6.1.4.1.4515.1.6.3.1.3.2not-accessiblecurrent
sonetSectionThresholdEntry
OBJECT-TYPE
An entry in the table of SONET Section trap thresholds.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1not-accessiblecurrent
sonetSectionCurrentCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval CV-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.1INTEGERread-writecurrent
sonetSectionCurrentESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval ES-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.2INTEGERread-writecurrent
sonetSectionCurrentSESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval SES-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.5INTEGERread-writecurrent
sonetSectionCurrentSEFSThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval SEFS-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.6INTEGERread-writecurrent
sonetSectionDayCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day CV-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.7INTEGERread-writecurrent
sonetSectionDayESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day ES-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.8INTEGERread-writecurrent
sonetSectionDaySESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day SES-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.11INTEGERread-writecurrent
sonetSectionDaySEFSThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day SEFS-S counter. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.3.2.1.12INTEGERread-writecurrent
sonetSectionDayTable
OBJECT-TYPE
The SONET Section Day table. Contains various statistics collected by each SONET Section over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.1.3.15not-accessiblecurrent
sonetSectionDayEntry
OBJECT-TYPE
An entry in the SONET Section Day table.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1not-accessiblecurrent
sonetSectionDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of section related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.1INTEGER (0..33)read-onlycurrent
sonetSectionDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which this 1-day interval of sections measurements began on this interface.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.2DateAndTimeread-onlycurrent
sonetSectionDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.3TruthValueread-onlycurrent
sonetSectionDayCVs
OBJECT-TYPE
The section code violation (CV-S) count is the number of BIP-8 errors which were detected at the SONET section layer interface in a previous 1-day interval. Each section BIP-8 can detect up to eight errors per STS-N frame, with each error incrementing the CV counter. CVs for the section layer are collected using the BIP-8 in the B1 byte located in the section overhead of STS-1 number 1.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.4PerfTotalCountread-onlycurrent
sonetSectionDayESs
OBJECT-TYPE
The section errored second (ES-S) count is the number of 1-second intervals containing one or more BIP-8 error (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.5PerfTotalCountread-onlycurrent
sonetSectionDaySESs
OBJECT-TYPE
The section severely errored second (SES-S) count is the number of 1-second intervals containing sonetSevereErrorThreshold or more BIP-8 errors (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.8PerfTotalCountread-onlycurrent
sonetSectionDaySEFSs
OBJECT-TYPE
The section severely errored frame second (SEFS-S) count is the number of 1-second intervals containing one or more SEF defects which were encountered by the SONET section layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.9PerfTotalCountread-onlycurrent
sonetSectionDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.10TruthValueread-onlycurrent
sonetSectionDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.1.3.15.1.11INTEGERread-writecurrent
sonetSupLine
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.4
sonetLineDefaultThresholdTable
OBJECT-TYPE
The table of default thresholds for SONET Line counters.
1.3.6.1.4.1.4515.1.6.3.1.4.1not-accessiblecurrent
sonetLineDefaultThresholdEntry
OBJECT-TYPE
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1not-accessiblecurrent
sonetLineDefaultThresholdDirection
OBJECT-TYPE
The digital signal direction for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.1INTEGER {nearEnd(1), farEnd(2)}read-onlycurrent
sonetLineDefaultThresholdRate
OBJECT-TYPE
The digital signal rate for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.2INTEGER {vt1dot5(1), vtg(2), oc1(3), oc3(4), oc12(5), oc24(6), oc48(7), oc192(8)}read-onlycurrent
sonetLineDefaultCVThreshold
OBJECT-TYPE
The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.3INTEGERread-writecurrent
sonetLineDefaultESThreshold
OBJECT-TYPE
The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.4INTEGERread-writecurrent
sonetLineDefaultSESThreshold
OBJECT-TYPE
The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.7INTEGERread-writecurrent
sonetLineDefaultUASThreshold
OBJECT-TYPE
The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.9INTEGERread-writecurrent
sonetLineDefaultDayCVThreshold
OBJECT-TYPE
The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.10INTEGERread-writecurrent
sonetLineDefaultDayESThreshold
OBJECT-TYPE
The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.11INTEGERread-writecurrent
sonetLineDefaultDaySESThreshold
OBJECT-TYPE
The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.14INTEGERread-writecurrent
sonetLineDefaultDayUASThreshold
OBJECT-TYPE
The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.1.1.16INTEGERread-writecurrent
sonetLineThresholdTable
OBJECT-TYPE
The table of trap threshold values for SONET Line counters.
1.3.6.1.4.1.4515.1.6.3.1.4.2not-accessiblecurrent
sonetLineThresholdEntry
OBJECT-TYPE
An entry in the table of SONET Line trap thresholds.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1not-accessiblecurrent
sonetLineThresholdDirection
OBJECT-TYPE
The digital signal direction for which the threshold values apply.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.1INTEGER {nearEnd(1), farEnd(2)}read-onlycurrent
sonetLineCurrentCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.2INTEGERread-writecurrent
sonetLineCurrentESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.3INTEGERread-writecurrent
sonetLineCurrentSESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.4INTEGERread-writecurrent
sonetLineCurrentUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.5INTEGERread-writecurrent
sonetLineDayCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.6INTEGERread-writecurrent
sonetLineDayESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.7INTEGERread-writecurrent
sonetLineDaySESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.8INTEGER (0..65535)read-writecurrent
sonetLineDayUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current day UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.1.4.2.1.9INTEGERread-writecurrent
sonetLineDayTable
OBJECT-TYPE
The SONET Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.1.4.5not-accessiblecurrent
sonetLineDayEntry
OBJECT-TYPE
An entry in the SONET Line Day table.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1not-accessiblecurrent
sonetLineDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of near-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.1INTEGER (0..33)read-onlycurrent
sonetLineDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which this 1-day interval of near-end line measurements began on this interface.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.2DateAndTimeread-onlycurrent
sonetLineDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.3TruthValueread-onlycurrent
sonetLineDayCVs
OBJECT-TYPE
The line code violation (CV-L) count is the number of BIP-8 errors which were detected at the SONET line layer interface in a previous 1-day interval. Each line BIP-8 can detect up to eight errors per STS-1 frame, with each error incrementing the CV counter. CVs for the line layer are collected using the BIP-8s in the B2 byte located in the line overhead of STS-1. (Since all CVs on an STS-N line are counted together, this is equivalent to counting each error in the BIP-8N contained in the B2 bytes of the STS-N line overhead.) Thus, on an STS-N signal, up to 8 x N CVs may occure in each STS-N frame.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.5PerfTotalCountread-onlycurrent
sonetLineDayESs
OBJECT-TYPE
The line errored second (ES-L) count is the number of 1-second intervals containing one or more EDC error (B2 byte), or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.6PerfTotalCountread-onlycurrent
sonetLineDaySESs
OBJECT-TYPE
The line severely errored second (SES-L) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC errors (B2 byte) or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.9PerfTotalCountread-onlycurrent
sonetLineDayUASs
OBJECT-TYPE
The line unavailable second (UAS-L) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-Ls. The 10 SES-Ls are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-Ls. The 10 seconds with no SES-Ls are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.10PerfTotalCountread-onlycurrent
sonetLineDayPSC
OBJECT-TYPE
The number of protection switching occured.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.11PerfTotalCountread-onlycurrent
sonetLineDayPSD
OBJECT-TYPE
The length of time in seconds, where the protection unit was in service and the working unit was out of service, during the day.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.12PerfTotalCountread-onlycurrent
sonetLineDayFCs
OBJECT-TYPE
The number of failure counts occured during the day.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.13PerfTotalCountread-onlycurrent
sonetLineDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.14TruthValueread-onlycurrent
sonetLineDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.1.4.5.1.15INTEGERread-writecurrent
sonetSupFarEndLine
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.5
sonetFarEndLineDayTable
OBJECT-TYPE
The SONET Far End Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.1.5.3not-accessiblecurrent
sonetFarEndLineDayEntry
OBJECT-TYPE
An entry in the SONET Far End Line Day table.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1not-accessiblecurrent
sonetFarEndLineDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of far-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.1INTEGER (1..33)read-onlycurrent
sonetFarEndLineDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which this 1-day interval of far-end line measurements began on this interface.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.2DateAndTimeread-onlycurrent
sonetFarEndLineDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.3TruthValueread-onlycurrent
sonetFarEndLineDayCVs
OBJECT-TYPE
The far-end line code violation (CV-LFE) count is the number of REI-Ls which were detected at the SONET line layer interface in a previous 1-day interval. For EC-1 or OC-1, REI-L is bits 5 to 8 of the M0 byte; for EC-N or OC-N (N>2), M1 byte.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.5PerfTotalCountread-onlycurrent
sonetFarEndLineDayESs
OBJECT-TYPE
The far-end line errored second (ES-LFE) count is the number of 1-second intervals containing one or more REDC-Ls, or one or more RDI-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.6PerfTotalCountread-onlycurrent
sonetFarEndLineDaySESs
OBJECT-TYPE
The far-end line severely errored second (SES-LFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ls or one or more RDI-L defects which were detected by the SONET line layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.9PerfTotalCountread-onlycurrent
sonetFarEndLineDayUASs
OBJECT-TYPE
The far-end line unavailable second (UAS-LFE) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-LEFs. The 10 SES-LEFs are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-LEFs. The 10 seconds with no SES-LEFs are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.10PerfTotalCountread-onlycurrent
sonetFarEndLineDayFCs
OBJECT-TYPE
The far-end line failures count.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.11PerfTotalCountread-onlycurrent
sonetFarEndLineDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.12TruthValueread-onlycurrent
sonetFarEndLineDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.1.5.3.1.13INTEGERread-writecurrent
sonetTrap
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.1.6
sonetCounterId
OBJECT-TYPE
The OBJECT IDENTIFIER of the instance of the SONET counter that has crossed its threshold.
1.3.6.1.4.1.4515.1.6.3.1.6.1OBJECT IDENTIFIERaccessible-for-notifycurrent
sonetCounterValue
OBJECT-TYPE
The current value of the SONET counter that has crossed its threshold.
1.3.6.1.4.1.4515.1.6.3.1.6.2Integer32accessible-for-notifycurrent
sonetSupObjectsPath
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.2
sonetSupPath
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.2.1
sonetPathDefaultThresholdTable
OBJECT-TYPE
The table of default thresholds for SONET Path counters.
1.3.6.1.4.1.4515.1.6.3.2.1.1not-accessiblecurrent
sonetPathDefaultThresholdEntry
OBJECT-TYPE
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1not-accessiblecurrent
sonetPathDefaultThresholdDirection
OBJECT-TYPE
The digital signal direction for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.1INTEGER {nearEnd(1), farEnd(2)}read-onlycurrent
sonetPathDefaultThresholdRate
OBJECT-TYPE
The path digital signal rate for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.2INTEGER {sts1(1), sts3(2), sts12(3), sts24(4), sts48(5), sts192(6)}read-onlycurrent
sonetPathDefaultCVThreshold
OBJECT-TYPE
The default value for SONET CV-P and CV-PFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.3INTEGERread-writecurrent
sonetPathDefaultESThreshold
OBJECT-TYPE
The default value for SONET ES-P and ES-PFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.4INTEGERread-writecurrent
sonetPathDefaultSESThreshold
OBJECT-TYPE
The default value for SONET SES-P and SES-PFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.7INTEGERread-writecurrent
sonetPathDefaultUASThreshold
OBJECT-TYPE
The default value for SONET UAS-P and UAS-PFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.8INTEGERread-writecurrent
sonetPathDefaultDayCVThreshold
OBJECT-TYPE
The default value for SONET CV-P and CV-PFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.16INTEGERread-writecurrent
sonetPathDefaultDayESThreshold
OBJECT-TYPE
The default value for SONET ES-P and ES-PFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.17INTEGERread-writecurrent
sonetPathDefaultDaySESThreshold
OBJECT-TYPE
The default value for SONET SES-P and SES-PFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.20INTEGERread-writecurrent
sonetPathDefaultDayUASThreshold
OBJECT-TYPE
The default value for SONET UAS-P and UAS-PFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.1.1.21INTEGERread-writecurrent
sonetPathThresholdTable
OBJECT-TYPE
The table of trap threshold values for SONET Path counters.
1.3.6.1.4.1.4515.1.6.3.2.1.2not-accessiblecurrent
sonetPathThresholdEntry
OBJECT-TYPE
An entry in the table of SONET Path trap thresholds.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1not-accessiblecurrent
sonetPathThresholdDirection
OBJECT-TYPE
The digital signal direction for which the threshold values apply.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.1INTEGER {nearEnd(1), farEnd(2)}read-onlycurrent
sonetPathCurrentCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.2INTEGERread-writecurrent
sonetPathCurrentESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.3INTEGERread-writecurrent
sonetPathCurrentSESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.4INTEGERread-writecurrent
sonetPathCurrentUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.5INTEGERread-writecurrent
sonetPathDayCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.6INTEGERread-writecurrent
sonetPathDayESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.7INTEGERread-writecurrent
sonetPathDaySESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.8INTEGERread-writecurrent
sonetPathDayUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.2.1.2.1.9INTEGERread-writecurrent
sonetPathDayTable
OBJECT-TYPE
The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.2.1.17not-accessiblecurrent
sonetPathDayEntry
OBJECT-TYPE
An entry in the SONET Path Day table.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1not-accessiblecurrent
sonetPathDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.1INTEGER (1..33)read-onlycurrent
sonetPathDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which the 1-day interval of measurements began on this interface.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.2DateAndTimeread-onlycurrent
sonetPathDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.3TruthValueread-onlycurrent
sonetPathDayCVs
OBJECT-TYPE
The path code violation (CV-P) count is the number of BIP-8 errors which were detected at the STS-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-8 in the B3 byte located in the STS-path overhead.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.5PerfTotalCountread-onlycurrent
sonetPathDayESs
OBJECT-TYPE
The path errored second (ES-P) count is the number of 1-second intervals containing one or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.6PerfTotalCountread-onlycurrent
sonetPathDaySESs
OBJECT-TYPE
The path severely errored second (SES-P) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.9PerfTotalCountread-onlycurrent
sonetPathDayUASs
OBJECT-TYPE
The path unavailable second (UAS-P) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-Ps. The 10 SES-Ps are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-Ps. The 10 seconds with no SES-Ps are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.10PerfTotalCountread-onlycurrent
sonetPathDayFCs
OBJECT-TYPE
The number path failures count during a day.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.11PerfTotalCountread-onlycurrent
sonetPathDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.12TruthValueread-onlycurrent
sonetPathDayEBs
OBJECT-TYPE
The number path blocks in which one or more bits are in error counted during a day.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.13PerfTotalCountread-onlycurrent
sonetPathDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.2.1.17.1.14INTEGERread-writecurrent
sonetSupFarEndPath
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.2.2
sonetFarEndPathDayTable
OBJECT-TYPE
The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.2.2.3not-accessiblecurrent
sonetFarEndPathDayEntry
OBJECT-TYPE
An entry in the SONET Far End Path Day table.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1not-accessiblecurrent
sonetFarEndPathDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of far-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.1INTEGER (1..4)read-onlycurrent
sonetFarEndPathDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which the current interval of measurements began.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.2DateAndTimeread-onlycurrent
sonetFarEndPathDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.3TruthValueread-onlycurrent
sonetFarEndPathDayCVs
OBJECT-TYPE
The far-end path code violation (CV-PFE) count is the number of REI-Ps (bit 1-4 in G1 byte) which were detected at the SONET STS-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.5PerfTotalCountread-onlycurrent
sonetFarEndPathDayESs
OBJECT-TYPE
The far-end path errored second (ES-PFE) count is the number of 1-second intervals containing one or more REDC-P, or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were encountered by the SONET STS-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.6PerfTotalCountread-onlycurrent
sonetFarEndPathDaySESs
OBJECT-TYPE
The far-end path severely errored second (SES-PFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ps or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were detected by the SONET STS-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.9PerfTotalCountread-onlycurrent
sonetFarEndPathDayUASs
OBJECT-TYPE
The far-end path unavailable second (UAS-PFE) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-PFEs. The 10 SES-PFEs are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-PFEs. The 10 seconds with no SES-PFEs are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.10PerfTotalCountread-onlycurrent
sonetFarEndPathDayFCs
OBJECT-TYPE
The far-end path failures count.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.11PerfTotalCountread-onlycurrent
sonetFarEndPathDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.12TruthValueread-onlycurrent
sonetFarEndPathDayEBs
OBJECT-TYPE
The count of far-end path blocks in which one or more bits are in error.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.13PerfTotalCountread-onlycurrent
sonetFarEndPathDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.2.2.3.1.14INTEGERread-writecurrent
sonetSupObjectsVT
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.3
sonetSupVT
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.3.1
sonetVTDefaultThresholdTable
OBJECT-TYPE
The table of default thresholds for SONET Path counters.
1.3.6.1.4.1.4515.1.6.3.3.1.1not-accessiblecurrent
sonetVTDefaultThresholdEntry
OBJECT-TYPE
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1not-accessiblecurrent
sonetVTDefaultThresholdDirection
OBJECT-TYPE
The digital signal direction for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.1INTEGER {nearEnd(1), farEnd(2)}not-accessiblecurrent
sonetVTDefaultThresholdRate
OBJECT-TYPE
The path digital signal rate for which the default threshold values apply.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.2INTEGER {vt1dot5(1), vtg(2)}not-accessiblecurrent
sonetVTDefaultCVThreshold
OBJECT-TYPE
The default value for SONET CV-V and CV-VFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.3INTEGER (1..16383)read-writecurrent
sonetVTDefaultESThreshold
OBJECT-TYPE
The default value for SONET ES-V and ES-VFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.4INTEGER (1..900)read-writecurrent
sonetVTDefaultSESThreshold
OBJECT-TYPE
The default value for SONET SES-V and SES-VFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.5INTEGER (1..900)read-writecurrent
sonetVTDefaultUASThreshold
OBJECT-TYPE
The default value for SONET UAS-V and UAS-VFE counter 15-minute interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.6INTEGER (1..900)read-writecurrent
sonetVTDefaultDayCVThreshold
OBJECT-TYPE
The default value for SONET CV-V and CV-VFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.7INTEGER (1..1048575)read-writecurrent
sonetVTDefaultDayESThreshold
OBJECT-TYPE
The default value for SONET ES-V and ES-VFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.8INTEGER (1..65535)read-writecurrent
sonetVTDefaultDaySESThreshold
OBJECT-TYPE
The default value for SONET SES-V and SES-VFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.9INTEGER (1..4095)read-writecurrent
sonetVTDefaultDayUASThreshold
OBJECT-TYPE
The default value for SONET UAS-V and UAS-VFE counter 1-day interval thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.1.1.10INTEGER (1..4095)read-writecurrent
sonetVTThresholdTable
OBJECT-TYPE
The table of trap threshold values for SONET Path counters.
1.3.6.1.4.1.4515.1.6.3.3.1.2not-accessiblecurrent
sonetVTThresholdEntry
OBJECT-TYPE
An entry in the table of SONET Path trap thresholds.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1not-accessiblecurrent
sonetVTCurrentCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.1INTEGER (0..900)read-writecurrent
sonetVTCurrentESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.2INTEGER (0..900)read-writecurrent
sonetVTCurrentSESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.3INTEGER (0..900)read-writecurrent
sonetVTCurrentUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 15-minute interval UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.4INTEGER (0..900)read-writecurrent
sonetVTDayCVThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.5INTEGER (0..65535)read-writecurrent
sonetVTDayESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.6INTEGER (0..65535)read-writecurrent
sonetVTDaySESThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.7INTEGER (0..65535)read-writecurrent
sonetVTDayUASThreshold
OBJECT-TYPE
The trap threshold value for the interface's current 1-day UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used.
1.3.6.1.4.1.4515.1.6.3.3.1.2.1.8INTEGER (0..65535)read-writecurrent
sonetVTDayTable
OBJECT-TYPE
The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.3.1.17not-accessiblecurrent
sonetVTDayEntry
OBJECT-TYPE
An entry in the SONET Path Day table.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1not-accessiblecurrent
sonetVTDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.1INTEGER (1..33)read-onlycurrent
sonetVTDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which the 1-day interval of measurements began on this interface.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.2DateAndTimeread-onlycurrent
sonetVTDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.3TruthValueread-onlycurrent
sonetVTDayFCs
OBJECT-TYPE
The near-end path failure count (FC-V) is the number of occurences of near-end path failure events encountered by the SONET path layer interface in a previous 1-day interval. A near-end path failure event begins when the first of any of LOP-V, AIS-V or UNEQ-V failures is declared; a near-end path failure event ends when all LOP-V, AIS-V and UNEQ-V failures have cleared.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.4PerfTotalCountread-onlycurrent
sonetVTDayCVs
OBJECT-TYPE
The path code violation (CV-V) count is the number of BIP-2 errors which were detected at the VT-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-2 in the V5 byte located in the VT-path overhead.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.5PerfTotalCountread-onlycurrent
sonetVTDayESs
OBJECT-TYPE
The path errored second (ES-V) count is the number of 1-second intervals containing one or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.6PerfTotalCountread-onlycurrent
sonetVTDaySESs
OBJECT-TYPE
The path severely errored second (SES-V) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.7PerfTotalCountread-onlycurrent
sonetVTDayUASs
OBJECT-TYPE
The path unavailable second (UAS-V) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-Vs. The 10 SES-Vs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-Vs. The 10 seconds with no SES-Vs are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.8PerfTotalCountread-onlycurrent
sonetVTDayEBs
OBJECT-TYPE
The number VT path blocks in which one or more bits are in error counted during a day.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.9PerfTotalCountread-onlycurrent
sonetVTDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.10TruthValueread-onlycurrent
sonetVTDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.3.1.17.1.11INTEGERread-writecurrent
sonetSupFarEndVT
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.3.3.2
sonetFarEndVTDayTable
OBJECT-TYPE
The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation.
1.3.6.1.4.1.4515.1.6.3.3.2.3not-accessiblecurrent
sonetFarEndVTDayEntry
OBJECT-TYPE
An entry in the SONET Far End Path Day table.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1not-accessiblecurrent
sonetFarEndVTDayNumber
OBJECT-TYPE
A number which identifies the 1-day interval for which the set of far-end VT-path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.1INTEGER (1..4)read-onlycurrent
sonetFarEndVTDayStartTime
OBJECT-TYPE
This variable indicates the date and time at which the current interval of measurements began.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.2DateAndTimeread-onlycurrent
sonetFarEndVTDayValidData
OBJECT-TYPE
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.3TruthValueread-onlycurrent
sonetFarEndVTDayFCs
OBJECT-TYPE
The far-end path failure count (FC-VFE) is the number of occurences of far-end path failure events detected by the SONET VT-path layer interface in a previous 1-day interval. A far-end path failure event begins when the first of any remote failure indication (RFI-V, RFI-V server, or RFI-V connectivity) failure is declared; a far-end path failure event ends when all RFI-V, RFI-V server, or RFI-V connectivity failures are cleared.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4PerfTotalCountread-onlycurrent
sonetFarEndVTDayCVs
OBJECT-TYPE
The far-end path code violation (CV-VFE) count is the number of REI-Vs (bit 1-4 in G1 byte) which were detected at the SONET VT-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.5PerfTotalCountread-onlycurrent
sonetFarEndVTDayESs
OBJECT-TYPE
The far-end path errored second (ES-VFE) count is the number of 1-second intervals containing one or more REDC-V, or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were encountered by the SONET VT-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.6PerfTotalCountread-onlycurrent
sonetFarEndVTDaySESs
OBJECT-TYPE
The far-end path severely errored second (SES-VFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Vs or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were detected by the SONET VT-path layer interface in a previous 1-day interval.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.7PerfTotalCountread-onlycurrent
sonetFarEndVTDayUASs
OBJECT-TYPE
The far-end path unavailable second (UAS-VFE) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-VFEs. The 10 SES-VFEs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-VFEs. The 10 seconds with no SES-VFEs are excluded from unavailable time.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.8PerfTotalCountread-onlycurrent
sonetFarEndVTDayEBs
OBJECT-TYPE
The number VT path blocks in which one or more bits are in error counted during a day detected by the Far End.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.9PerfTotalCountread-onlycurrent
sonetFarEndVTDayTcaFlag
OBJECT-TYPE
TRUE if one of the counters crossed the threshold during the day.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.10TruthValueread-onlycurrent
sonetFarEndVTDayReset
OBJECT-TYPE
Writing this object reset the PM counters of this interval.
1.3.6.1.4.1.4515.1.6.3.3.2.3.1.11INTEGERread-writecurrent

Notifications

NameOIDStatus
sonetThresholdCrossing
NOTIFICATION-TYPE
This notification signifies that a counter has crossed its designated threshold. The term 'threshold crossing' means that a threshold has been reached or exceeded. A threshold crossing alert message (trap) signifies a performance degredation at or above the preset threshold value.
1.3.6.1.4.1.4515.1.6.3.1.6.3current