MIBs Depot

SL-SONET-MIB

Registered at
1.3.6.1.4.1.4515.1.6
Last updated
2000-08-28 00:00
Organization
PacketLight Networks Ltd.
Namespace
packetlight
Source file
SL-SONET-MIB
Digest
sha256:50f9a1b9f6fea112bbfdc06889e19504a7ebf7e1dfc4697ecfc6e76fb75e84fa

Description

This MIB module describes the SiteLight SONET Service. The mib contains the extensions required for the rfc2558.

Contact

Omri_Viner@PacketLight.com

Imports

FromSymbols
IF-MIBInterfaceIndex, ifIndex
PerfHist-TC-MIBPerfCurrentCount, PerfIntervalCount, PerfTotalCount
SL-NE-MIBsitelight
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SL-NE-MIB
SL-SONET-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.4515.1.6.3sonetSupPmMIBSL-SONET-SUP-PM-MIB

Textual conventions

NameOIDSyntaxAccessStatus
SignalLabel
TEXTUAL-CONVENTION
STS path signal label -- one byte, C2, class A, is allocated to indicate the construction of the STS SPE. The following hex values of the C2 byte has been defined.
current

Objects

NameOIDSyntaxAccessStatus
slSonetConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.1
slSonetConfigTable
OBJECT-TYPE
The SONET/SDH configuration table. This table has objects for configuring sonet lines.
1.3.6.1.4.1.4515.1.6.1.1not-accessiblecurrent
slSonetConfigEntry
OBJECT-TYPE
An entry in the table. There is an entry for each SONET line in the table. Entries are automatically created for an ifType value of sonet(39). 'ifAdminStatus' from the ifTable must be used to enable or disable a line. By default, the line state is down.
1.3.6.1.4.1.4515.1.6.1.1.1not-accessiblecurrent
slSonetConfigFrameScramble
OBJECT-TYPE
This object is used to disable or enable the Scrambling option in SONET line. Please refer to GR-253-CORE for frame scrambling.
1.3.6.1.4.1.4515.1.6.1.1.1.1INTEGER {disabled(1), enabled(2)}read-writecurrent
slSonetConfigType
OBJECT-TYPE
This object represents the configured line type for Trunks: sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk) sonetSts192c(12) - 1 x Sts192 (10Gb Trunk) sonetStsOther(13) - for OC-n interfaces see slSonetFsTable.
1.3.6.1.4.1.4515.1.6.1.1.1.2INTEGER {sonetSts3(1), sonetSts3c(2), sonetSts12(3), sonetSts12c(4), sonetSts48c(5), sonetSts3cx4(6), sonetSts48(7), sonetSts3cx16(8), sonetSts3x16(9), sonetSts12cx4(10), sonetSts12x4(11), sonetSts192c(12), sonetStsOther(13)}read-writecurrent
slSonetConfigDccSelection
OBJECT-TYPE
This object selects the DCC type.
1.3.6.1.4.1.4515.1.6.1.1.1.3INTEGER {sonetLineDcc(1), sonetSectionDcc(2), sonetInband(3)}read-writecurrent
slSonetResetAllCounters
OBJECT-TYPE
Setting this variable to 1 will cause all of the counters (performance regsters) on this SONET interface to be initialized to zero (0).
1.3.6.1.4.1.4515.1.6.1.1.1.4INTEGER {resetCounters(1)}read-writecurrent
slSonetPortThresholdTrapEnable
OBJECT-TYPE
This variable indicates whether threshold traps should be generated for this SONET interface.
1.3.6.1.4.1.4515.1.6.1.1.1.5INTEGER {enabled(1), disabled(2)}read-writecurrent
slSonetConfigSdThreshold
OBJECT-TYPE
This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to -n where n is between 5 and 9 (read-write).
1.3.6.1.4.1.4515.1.6.1.1.1.6INTEGER (5..9)read-writecurrent
slSonetConfigSfThreshold
OBJECT-TYPE
This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5. (read-write)
1.3.6.1.4.1.4515.1.6.1.1.1.7INTEGER (3..5)read-writecurrent
slSonetCompression
OBJECT-TYPE
This object applies only for trunk ports. It specifies if the packets should be compressed. 0 - Means no POS compression, 1 - Means POS compression with CRC-32. 2 - Means POS compression with CRC-16. Note that the two connected trunks should be configured to the same value. Note also that the BW calculation of the OC-n should be changed according to this value.
1.3.6.1.4.1.4515.1.6.1.1.1.9INTEGER {uncompress(0), posCompress32(1), posCompress16(2)}read-writecurrent
slSonetOverheadTunneling
OBJECT-TYPE
The section and line overhead tunneling configuration: none(0) - no tunneling support lineDcc(1) - line DCC tunneling k1k2(2) - line DCC + protection k byte full(3) - all transport overhead bytes are tunneled
1.3.6.1.4.1.4515.1.6.1.1.1.10INTEGER {none(0), lineDcc(1), k1k2(2), full(3)}read-writecurrent
slSonetLopBitmask
OBJECT-TYPE
The LOP status. Each bit of the bits represent the status of the LOP alarm in corresponding STS. For a path with more than a single STS, only the value of the first STS in the path is relevant. This object is relevant only for the OC-N cards and not for the Trunk. In the next future this object will be replaced with an object of a new table that shall describe the OC-N frame structure.
1.3.6.1.4.1.4515.1.6.1.1.1.11Counter64read-onlycurrent
slSonetTdmTrunk
OBJECT-TYPE
This object is applicable only to the OC-n ports. TRUE - means that the OC-n port is used as a TDM Trunk. FLASE - means normal OC-n port.
1.3.6.1.4.1.4515.1.6.1.1.1.12TruthValueread-writecurrent
slSonetFsApply
OBJECT-TYPE
Writing to this object activate the slSonetFsTable setting. This allow the NMS to do many changes to the slSonetFsTable and then APPLY them at once. This prevent from going through unconsistent steps. This object always returns the value 0.
1.3.6.1.4.1.4515.1.6.1.1.1.13INTEGERread-writecurrent
slSonetTxLte
OBJECT-TYPE
The SS bits to transmit (bits 5,6 in H1,H1*).
1.3.6.1.4.1.4515.1.6.1.1.1.14INTEGER {ssb00(1), ssb10(2), auto(5)}read-writecurrent
slSonetReceivedLte
OBJECT-TYPE
The detected LTE type, according to the received SS bits (bits 5,6 in H1,H1*).
1.3.6.1.4.1.4515.1.6.1.1.1.15INTEGER {ssb00(1), ssb10(2), ssb01(3), ssb11(4), ssbinv(5)}read-onlycurrent
slSonetResetPmThreshold
OBJECT-TYPE
Setting this variable to 1 will reset the PM threshold parameters to the factory defaults.
1.3.6.1.4.1.4515.1.6.1.1.1.16INTEGER {resetCounters(1)}read-writecurrent
slSonetResetAlsParams
OBJECT-TYPE
Setting this variable to 1 will reset the ALS parameters to the factory defaults.
1.3.6.1.4.1.4515.1.6.1.1.1.17INTEGER {resetCounters(1)}read-writecurrent
slSonetTransceiverType
OBJECT-TYPE
The tranceiver type.
1.3.6.1.4.1.4515.1.6.1.1.1.18INTEGER {none(1), shortWave(2), longWave(3)}read-onlycurrent
slSonetTransceiverMedia
OBJECT-TYPE
The tranceiver media.
1.3.6.1.4.1.4515.1.6.1.1.1.19INTEGER {none(1), sm(2), mm(3)}read-onlycurrent
slSonetOh
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.2
slSonetOhTrace
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.2.1
slSonetTraceTable
OBJECT-TYPE
The SONET/SDH Trace table. This table contains objects for tracing the sonet section and path.
1.3.6.1.4.1.4515.1.6.2.1.1not-accessiblecurrent
slSonetTraceEntry
OBJECT-TYPE
An entry in the trace table. Entries exist for active sonet interfaces. The objects in this table are used to verify continued connection between the two ends of the line.
1.3.6.1.4.1.4515.1.6.2.1.1.1not-accessiblecurrent
slSonetTraceMode
OBJECT-TYPE
Determine the Trace Message Mode.
1.3.6.1.4.1.4515.1.6.2.1.1.1.1INTEGER {enable(1), disable(2), monitoring(3)}read-writecurrent
slSonetTraceToTransmit
OBJECT-TYPE
Sonet Trace To Transmit. This is string that is transmitted to perform Sonet trace diagnostics. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed. The Agent is responsible to pad the end of the string with <CR><LF>.
1.3.6.1.4.1.4515.1.6.2.1.1.1.2DisplayString (SIZE(0..62))read-writecurrent
slSonetTraceToExpect
OBJECT-TYPE
Sonet Trace Massage To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'slSonetTraceFailure' indicates whether a trace mismatch occurred. The default value is a zero-length string. The Agent is responsible to pad the end of the string with <CR><LF>.
1.3.6.1.4.1.4515.1.6.2.1.1.1.3DisplayString (SIZE(0..62))read-writecurrent
slSonetTraceFailure
OBJECT-TYPE
The value of this object is set to 'true' when Sonet Section received trace does not match the 'slSonetTraceToExpect'.
1.3.6.1.4.1.4515.1.6.2.1.1.1.4TruthValueread-onlycurrent
slSonetTraceReceived
OBJECT-TYPE
This object is used to view the Sonet Trace Message that is received by the receiving terminal. The Agent is responsible to pad the end of the string with <CR><LF>.
1.3.6.1.4.1.4515.1.6.2.1.1.1.5DisplayString (SIZE(0..62))read-onlycurrent
slSonetOhSl
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.2.2
slSonetSlTable
OBJECT-TYPE
The SONET/SDH Signal Label table. This table contains signal label for the sonet path.
1.3.6.1.4.1.4515.1.6.2.2.1not-accessiblecurrent
slSonetSlEntry
OBJECT-TYPE
An entry in the SONET/SDH Signal Label table. The entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line.
1.3.6.1.4.1.4515.1.6.2.2.1.1not-accessiblecurrent
slSonetSlToTransmit
OBJECT-TYPE
Sonet Signal Label To Transmit.
1.3.6.1.4.1.4515.1.6.2.2.1.1.2SignalLabelread-writecurrent
slSonetSlToExpect
OBJECT-TYPE
Sonet Signal Label To Expect.
1.3.6.1.4.1.4515.1.6.2.2.1.1.3SignalLabelread-writecurrent
slSonetSlFailure
OBJECT-TYPE
The value of this object is set to 'true' when Sonet received signal label does not match the 'slSonetSlToExpect'.
1.3.6.1.4.1.4515.1.6.2.2.1.1.4TruthValueread-onlycurrent
slSonetSlReceived
OBJECT-TYPE
This object is used to view the Sonet Signal Label that is received by the receiving terminal.
1.3.6.1.4.1.4515.1.6.2.2.1.1.5INTEGER (0..255)read-onlycurrent
slSonetOhTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.2.3
slSonetPos
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.6
slSonetPosTable
OBJECT-TYPE
The POS PM Table.
1.3.6.1.4.1.4515.1.6.6.1not-accessiblecurrent
slSonetPosEntry
OBJECT-TYPE
The entries exist for active Trunk sonet lines ifType = pos(171). The objects in this table are used to moitor the POS layer.
1.3.6.1.4.1.4515.1.6.6.1.1not-accessiblecurrent
slSonetPosFcs
OBJECT-TYPE
The Number of FCS Errors.
1.3.6.1.4.1.4515.1.6.6.1.1.1Gauge32read-onlycurrent
slSonetPosAbort
OBJECT-TYPE
The Number of Aborted packets.
1.3.6.1.4.1.4515.1.6.6.1.1.2Gauge32read-onlycurrent
slSonetPosMinViolation
OBJECT-TYPE
The Number of Minimum length violation packets.
1.3.6.1.4.1.4515.1.6.6.1.1.3Gauge32read-onlycurrent
slSonetPosMaxViolation
OBJECT-TYPE
The Number of Maximum length violation packets.
1.3.6.1.4.1.4515.1.6.6.1.1.4Gauge32read-onlycurrent
slSonetPosRxfifoDiscard
OBJECT-TYPE
The Number of packets discarded due to RXFIFO error.
1.3.6.1.4.1.4515.1.6.6.1.1.5Gauge32read-onlycurrent
slSonetPosPacketReceived
OBJECT-TYPE
The Number of packets received.
1.3.6.1.4.1.4515.1.6.6.1.1.6Counter64read-onlycurrent
slSonetPosPacketReceivedOk
OBJECT-TYPE
The Number of error free packets.
1.3.6.1.4.1.4515.1.6.6.1.1.7Counter64read-onlycurrent
slSonetAls
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.7
slSonetAlsTable
OBJECT-TYPE
The ALS configuration Table.
1.3.6.1.4.1.4515.1.6.7.1not-accessiblecurrent
slSonetAlsEntry
OBJECT-TYPE
The entries exist for active sonet lines ifType = sonet(39). The objects in this table are used to configure the ALS algorithm.
1.3.6.1.4.1.4515.1.6.7.1.1not-accessiblecurrent
slSonetAlsMode
OBJECT-TYPE
Enable/Disable the ALS algorithm. Note that the if the Laser Admin Status is 'down' the ALS mechanism is not operational.
1.3.6.1.4.1.4515.1.6.7.1.1.1INTEGER {enable(1), disable(2)}read-writecurrent
slSonetLosDeclareTime
OBJECT-TYPE
Time to declare optical LOS present or clear: 550 +- 50 msec.
1.3.6.1.4.1.4515.1.6.7.1.1.2INTEGER {ms500(1), ms550(2), ms600(3)}read-writecurrent
slSonetTestPulseTime
OBJECT-TYPE
Manual restart for test Pulse time (in manual restart) - 90+-10 sec.
1.3.6.1.4.1.4515.1.6.7.1.1.3INTEGER {s80(1), s90(2), s100(3)}read-writecurrent
slSonetManualPulseTime
OBJECT-TYPE
Manual restart Pulse time (in manual mode) - 2+-0.25 sec.
1.3.6.1.4.1.4515.1.6.7.1.1.4INTEGER {ms1750(1), ms2000(2), ms2250(3)}read-writecurrent
slSonetAutomaticPulseTime
OBJECT-TYPE
Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec.
1.3.6.1.4.1.4515.1.6.7.1.1.5INTEGER {ms1750(1), ms2000(2), ms2250(3)}read-writecurrent
slSonetAutomaticDelayTime
OBJECT-TYPE
In Automatic mode. The delay between two laser re-activations.
1.3.6.1.4.1.4515.1.6.7.1.1.6INTEGER (60..300)read-writecurrent
slSonetLaserTestActivate
OBJECT-TYPE
Activate the laser for test operation.
1.3.6.1.4.1.4515.1.6.7.1.1.7INTEGER {activate(1)}read-writecurrent
slSonetLaserManualActivate
OBJECT-TYPE
Activate the laser manual operation.
1.3.6.1.4.1.4515.1.6.7.1.1.8INTEGER {activate(1)}read-writecurrent
slSonetFs
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.8
slSonetFsTable
OBJECT-TYPE
The frame structure configuration Table. In order to define a new path the NMS should create and configure an entry in this table. The table is also used to monitor the status of the LOP alarm per path.
1.3.6.1.4.1.4515.1.6.8.1not-accessiblecurrent
slSonetFsEntry
OBJECT-TYPE
The entries exist for sonet paths ifType = sonet(39). The objects in this table are used to configure the frame structure. Each OC-N line interface shall maintain a static table with number of lines equal to the N. Initially the table will be initialized to STS-Nc.
1.3.6.1.4.1.4515.1.6.8.1.1not-accessiblecurrent
slSonetFsIfIndex
OBJECT-TYPE
The interface index.
1.3.6.1.4.1.4515.1.6.8.1.1.1InterfaceIndexread-onlycurrent
slSonetFsSts
OBJECT-TYPE
The number of the first STS in the path. Note that no all values are legal because there is no support for combus with mixed structure
1.3.6.1.4.1.4515.1.6.8.1.1.2INTEGERread-onlycurrent
slSonetFsWidth
OBJECT-TYPE
The number STS's in the path. The width is only valid for the first STS in the path. The other STSs of the path will have width=0.
1.3.6.1.4.1.4515.1.6.8.1.1.3INTEGERread-writecurrent
slSonetFsFullPathTermination
OBJECT-TYPE
FALSE - means partial path termination (only LOP alarm). TRUE - include full support for path Alarms and PM counters.
1.3.6.1.4.1.4515.1.6.8.1.1.4TruthValueread-writecurrent
slSonetFsGranularity
OBJECT-TYPE
This value is set by the NMS according to the configured frame structure. Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1). Otherwise the value should be vc3(2).
1.3.6.1.4.1.4515.1.6.8.1.1.5INTEGER {vc4(1), vc3(2)}read-writecurrent
slSonetTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.6.11

Notifications

NameOIDStatus
slSonetFsTableChange
NOTIFICATION-TYPE
A slSonetFsTableChange trap is sent when the content of the slSonetFsTable is changed. This trap may be used by the NMS to identify the removal of path interfaces, or addition of new path interfaces
1.3.6.1.4.1.4515.1.6.11.1current