MIBs Depot

RS-XX8000-DVB-TX-MIB

Registered at
1.3.6.1.4.1.2566.127.1.2.167.4
1.3.6.1.4.1.2566.149.1.163.3
Last updated
2012-11-01 08:00
Organization
Rohde&Schwarz GmbH & Co. KG
Revisions
2012-11-01 08:00, 2012-09-03 08:00, 2011-05-12 08:00, 2011-02-28 08:00, 2010-12-02 08:00, 2010-10-13 08:00, 2010-05-21 08:00, 2010-04-16 08:00, 2010-02-02 08:00, 2010-01-29 08:00, 2010-01-12 08:00, 2009-12-18 08:00, 2009-11-26 08:00, 2009-11-13 08:00, 2009-10-08 08:00, 2009-09-10 08:00, 2009-07-16 08:00, 2009-06-26 08:00, 2009-06-17 09:00, 2009-05-28 09:00, 2009-03-30 09:00, 2009-02-12 15:00, 2009-01-29 09:00, 2009-01-06 16:00, 2008-12-12 14:30, 2008-10-23 08:00, 2008-10-08 10:30, 2008-09-10 15:00, 2008-08-29 10:00, 2008-08-26 09:00, 2008-07-23 10:00, 2008-05-05 09:30, 2008-03-31 11:00, 2007-12-07 17:00, 2007-09-10 11:00, 2007-08-09 14:00, 2007-07-11 16:00, 2007-03-08 10:00, 2006-12-21 10:00
Namespace
rs
Source file
RS-XX8000-DVB-TX-MIB
Digest
sha256:ecf89d7ebe944ef8a761f2638e6d65a5d075a67a42d77f1efc71d7e90a90e758

Description

This MIB defines transmitting systems from Rohde & Schwarz. Use this MIB if your system meets the following requirements: - series XX8000 (NetCCU800), - DVB, - transmitter reserve concept SingleTx, DualDrive, Active Reserve or Passive Reserve. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB - RS-XX8000-COMMON-MIB - mandatory for this MIB

Contact

Torsten Huebscher Department 7TS2 Broadcasting Division Muehldorfstrasse 15 81671 Munich, Germany torsten.huebscher@rohde-schwarz.com

Imports

FromSymbols
RS-XX8000-COMMON-MIBEqualizerCalibrationState, EventClass, EventMask, EventMaxEntryNumber, EventPriority, EventState, FailDelayMode, FailDelayStatus, FloatingPoint, IndexAB, IndexAmplifier, IndexRack, InputSource, LogbookEntryMessagesExcTv, LogbookEntryMessagesNetCCU, LogbookEntryMessagesOST, LogbookEntrySlope, LogbookMaxEntryNumber, ProdInfoModuleNameTv, ReadableString, SwitchOnOff, Sx801AmplifierState, TimeOfDay, Trigger, TvStandard, eventAlarmClass, eventAlarmPriority, eventEvent, indexAB, indexAmplifier, indexRack, rsXx8000, rsXx8000MibModule
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

RS-COMMON-MIB
RS-XX8000-COMMON-MIB
RS-XX8000-DVB-TX-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
rsXx8000DvbTx
OBJECT-IDENTITY
Xx8000 DVB transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4current
rsXx8000DvbTxObjs
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.1
commandsTxTable
OBJECT-TYPE
This table contains important commands for the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1not-accessiblecurrent
commandsTxEntry
OBJECT-TYPE
An entry for a designated transmitter and device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1not-accessiblecurrent
cmdTxResetSumFault
OBJECT-TYPE
Reset all faults (in all modules) of the transmitter. You reset a designated transmitter (NetCCU, Exciters, Outputstages). An equivalent would be pressing RESET at this transmitters frontpanel. A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.1Triggerread-writecurrent
cmdTxParametersetLoad
OBJECT-TYPE
This loads the desired parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.2Integer32 (1..8)read-writecurrent
cmdTxParametersetSave
OBJECT-TYPE
This saves the current settings to a designated parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.3Integer32 (1..8)read-writecurrent
cmdTxParametersetReSave
OBJECT-TYPE
This saves the changes to the current parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.4Triggerread-writeobsolete
cmdTxOperationModeProgram
OBJECT-TYPE
This switches the program path of the transmitter on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.5SwitchOnOffread-writecurrent
cmdTxOperationModeReserve
OBJECT-TYPE
This switches the reserve path of the transmitter on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.6SwitchOnOffread-writecurrent
cmdTxOpModeExcAutomatic
OBJECT-TYPE
This switches the exciter automatic on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.7SwitchOnOffread-writecurrent
cmdTxOpModeOstAutomatic
OBJECT-TYPE
This switches the outputstage automatic on/off. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.8SwitchOnOffread-writecurrent
cmdTxPreselectExciter
OBJECT-TYPE
This sets exciterA or exciterB to program path (antenna) of the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.9IndexABread-writecurrent
cmdTxPreselectOutputstage
OBJECT-TYPE
This sets - outputstageA or - outputstageB or - both to program path (antenna) of the transmitter, or it sets both to dummyload. The settings bothToAntenna(3) and bothToDummyLoad(4) are only settable for ActiveReserve systems. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.10INTEGER {outputstageA(1), outputstageB(2), bothToAntenna(3), bothToDummyLoad(4)}read-writecurrent
cmdTxDelayTimeExcAutomatic
OBJECT-TYPE
This sets the exciter automatic delay time.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.11Integer32 (1..60)read-writecurrent
cmdTxDelayTimeOstAutomatic
OBJECT-TYPE
This sets the outputstage automatic delay time. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.12Integer32 (1..60)read-writecurrent
cmdTxRfSwitch
OBJECT-TYPE
RF switch for single-ended systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.13INTEGER {antenna(1), dummyLoad(2)}read-writecurrent
cmdTxSystemMode
OBJECT-TYPE
This object gives you the possibility of switching the TV standard of a whole system with NetCCU with only one command. Not applicable for N+1 or NTx systems. The value 'test' cannot be written.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.15TvStandardread-writecurrent
cmdTxProgramExciterPrio
OBJECT-TYPE
Enables/Disables priority usage of program exciter
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.20SwitchOnOffread-writecurrent
cmdTxChangeOver
OBJECT-TYPE
Performs a change over
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.21Triggerread-writecurrent
cmdTxSwitchPosition
OBJECT-TYPE
Shows the actual switch position. The program exciter is connected to input 1 (RF IN 1), the control exciter is connected to input 2 (RF IN 2) of the base amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.22INTEGER {undefined(1), controlExcOnAmp(2), programExcOnAmp(3)}read-onlycurrent
cmdDeviceIdx
OBJECT-TYPE
This column is used to show parameters for both exiters, if you have dualdrive transmitters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.30IndexABnot-accessiblecurrent
cmdExcOpModeInputAutomatic
OBJECT-TYPE
Activates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be used instead.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.31SwitchOnOffread-writecurrent
cmdExcPreselectInput
OBJECT-TYPE
This sets the preselection of a transmitters input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.32INTEGER {input1(1), input2(2)}read-writecurrent
cmdExcMode
OBJECT-TYPE
Switch between DVB-T and DVB-H.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.33INTEGER {dvbT(1), dvbH(2)}read-writecurrent
cmdExcNetworkMode
OBJECT-TYPE
Switch between Single Frequency Networks (SFN) and Multiple Frequency Networks (MFN).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.34INTEGER {mfn(1), sfn(2)}read-writecurrent
cmdExcTPSSource
OBJECT-TYPE
Transmitted TPS parameters can be adjusted manually inside the transmitter or automatically via MIP from the SFN adaptor.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.35INTEGER {manualPresets(1), mip(2)}read-writecurrent
cmdExcEnableCellID
OBJECT-TYPE
This enables the Cell ID insertion. The length indicator will be adjusted.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.36SwitchOnOffread-writecurrent
cmdExcTxAddress
OBJECT-TYPE
This is the unique address of the transmitter to reference specific settings in the MIP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.37Integer32 (0..65535)read-writecurrent
cmdExcTxAutomatic
OBJECT-TYPE
This enables Tx specific parameters from the MIP data caroussel (e.g. time offset, frequency offset).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.38SwitchOnOffread-writecurrent
cmdExcInputAutoSwitch
OBJECT-TYPE
Activates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be used instead. This object is deprecated. It's recommended to use cmdExcOpModeInputAutomatic instead.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.39SwitchOnOffread-writedeprecated
cmdExcInputSeamless
OBJECT-TYPE
If the datastreams on both inputs are syncronised a seamless switch is possible. With this parameter the seamless switch can be suppressed to enable a check of the input automatic.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.40SwitchOnOffread-writecurrent
cmdExcInputPriority
OBJECT-TYPE
Equal: There are no differences between both inputs. If a failure on the current input is detected it will be switched to the reserve input. It stays there until the reserve shows a failure. Prior: Whenever possible a certain input shall be used. If a failure is detected the reserve will be used as short as possible.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.41INTEGER {equal(1), prior(2)}read-writecurrent
cmdExcInputCheckTimeForward
OBJECT-TYPE
This time has to elapse before the current input switches to the reserve input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.42Integer32 (0..600)read-writecurrent
cmdExcInputCheckTimeSwitchback
OBJECT-TYPE
This time has to elapse before the automatic switches back from the reserve to a preselected input. This value has no effect if the priority is set to equal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.43Integer32 (0..600)read-writecurrent
cmdExcInputMuteOnFail
OBJECT-TYPE
If a loss of input signal is detected, the exciter mutes.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.44INTEGER {mute(1), noMute(2)}read-writecurrent
cmdExcInputManualPreseletionHP1
OBJECT-TYPE
The data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.45INTEGER {auto(1), asi(2), smpte(3)}read-writecurrent
cmdExcInputManualPreseletionHP2
OBJECT-TYPE
The data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.46INTEGER {auto(1), asi(2), smpte(3)}read-writecurrent
cmdExcInputManualPreseletionLP1
OBJECT-TYPE
The data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.47INTEGER {auto(1), asi(2), smpte(3)}read-writecurrent
cmdExcInputManualPreseletionLP2
OBJECT-TYPE
The data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.48INTEGER {auto(1), asi(2), smpte(3)}read-writecurrent
cmdExcTPSManualBandwidth
OBJECT-TYPE
The bandwidth used by the RF channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.49INTEGER {mhz5(1), mhz6(2), mhz7(3), mhz8(4)}read-writecurrent
cmdExcTPSManualFFTLength
OBJECT-TYPE
The used FFT length (depends on the DVB network).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.50INTEGER {k2(1), k8(2), k4(3)}read-writecurrent
cmdExcTPSManualGuardInterval
OBJECT-TYPE
The Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.51INTEGER {oneOf32(1), oneOf16(2), oneOf8(3), oneOf4(4)}read-writecurrent
cmdExcTPSManualConstellation
OBJECT-TYPE
This parameter sets the modulation mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.52INTEGER {qpsk(1), qam16(2), qam64(3)}read-writecurrent
cmdExcTPSManualAlpha
OBJECT-TYPE
An alpha greater than noHierarchy(1) enables the hierarchical coding mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.53INTEGER {noHierarchy(1), one(2), two(3), four(4)}read-writeobsolete
cmdExcTPSManualCellID
OBJECT-TYPE
Via Cell ID the receiver knows the current network.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.54Integer32 (0..65535)read-writecurrent
cmdExcTPSManualInterleaver
OBJECT-TYPE
Enables the bit interleaver for hierarchical coding
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.55INTEGER {indepth(1), nat(2)}read-writecurrent
cmdExcTPSManualCoderateHP
OBJECT-TYPE
The Code Rate sets the ratio between payload and error correction information.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.56INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)}read-writecurrent
cmdExcTPSManualCoderateLP
OBJECT-TYPE
The Code Rate sets the ratio between payload and error correction information.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.57INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)}read-writecurrent
cmdExcTPSManualTimeSlicingHP
OBJECT-TYPE
Enables the time slicing for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.58SwitchOnOffread-writecurrent
cmdExcTPSManualTimeSlicingLP
OBJECT-TYPE
Enables the time slicing for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.59SwitchOnOffread-writecurrent
cmdExcTPSManualFECHP
OBJECT-TYPE
Enables the forward error correction (FEC) for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.60SwitchOnOffread-writecurrent
cmdExcTPSManualFECLP
OBJECT-TYPE
Enables the forward error correction (FEC) for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.61SwitchOnOffread-writecurrent
cmdExcSFNStaticDelay
OBJECT-TYPE
A constant adjustable delay for tuning a SFN (-999999.9 ... 999999.9).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.62FloatingPointread-writecurrent
cmdExcSFNDeviationTime
OBJECT-TYPE
Leap In Time. This parameter sets the deviation in time when a readjustment of the dynamic delay is necessary.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.63Integer32 (1..100)read-writecurrent
cmdExcFrequency
OBJECT-TYPE
This is the RF frequency.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.64Integer32 (47000000..1500000000)read-writecurrent
cmdExcReferenceSource
OBJECT-TYPE
The Source of the reference signal. The value internGPS is not valid for SX800.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.65INTEGER {intern(1), extern5Mhz(2), extern10Mhz(3), extern1PPS(4), internGPS(5)}read-writecurrent
cmdExcMuteOnPPSFail
OBJECT-TYPE
Select the behaviour if the external second pulse is not available.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.66INTEGER {off(1), onlyAtStartup(2), afterFailDelayTime(3)}read-writecurrent
cmdExcMuteOnReferenceFail
OBJECT-TYPE
Select the behaviour if the external reference is not available.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.67INTEGER {off(1), onlyAtStartup(2), afterFailDelayTime(3)}read-writecurrent
cmdExcRefFailDelayTime
OBJECT-TYPE
Adjusts the time after the RF will be muted in case of a reference problem. Zero hours means react immediately.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.68Integer32 (0..24)read-writecurrent
cmdExcTypeLossOfInput
OBJECT-TYPE
If the input signal is lost, either a warning or a fault can be generated. If you select fault here, a switchover to the reserve exciter will be executed when input signal is lost.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.69INTEGER {warning(1), fault(2)}read-writecurrent
cmdExcRfOutput
OBJECT-TYPE
Turns on/switches off the output signal. This switch takes the same effect as the switch on the frontpanel of the exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.70SwitchOnOffread-writecurrent
cmdExcRfOutputRegulation
OBJECT-TYPE
Turns on/switches off the automatic output level regulation.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.71SwitchOnOffread-writecurrent
cmdExcRfOutputManualRfLevel
OBJECT-TYPE
Adjusts the RF level (0.0 ... 100.0). The value relates to an attenuation of 0 dB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.72FloatingPointread-writecurrent
cmdExcRfOutputAttenuation
OBJECT-TYPE
Activates internal attenuators to reduce the output level of the exciter. Adjustable in steps of 3 dB only.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.73Integer32 (0..9)read-writecurrent
cmdExcRfOutputRfSlope
OBJECT-TYPE
Adjusts a slope in the RF signal (-50.0 ... 50.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.74FloatingPointread-writecurrent
cmdExcRfOutputModulationSlope
OBJECT-TYPE
Modulation slope (-50.0 ... 50.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.75FloatingPointread-writecurrent
cmdExcRfIqAdjustStart
OBJECT-TYPE
Starts the automatic IQ adjustment. It works for the current used local 1 frequency and lasts up to 5 minutes. In this time the output will be muted. During the adjustment no transmitter parameter shall be changed. Break will stop the automatic immediately. The IQ modulator looses its adjustment! Read values mean idle(1) and started(2).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.77INTEGER {break(1), start(2)}read-writecurrent
cmdExcRfIqAdjustTestsignal
OBJECT-TYPE
Generates a test signal to adjust the IQ modulation. It is necessary to disconnect the rf-cable to the output stages.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.78SwitchOnOffread-writecurrent
cmdExcRfIqAdjustBiasCoarseI
OBJECT-TYPE
Adjusts the offset for I in huge steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.79Integer32 (-1023..1023)read-writecurrent
cmdExcRfIqAdjustBiasCoarseQ
OBJECT-TYPE
Adjusts the offset for Q in huge steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.80Integer32 (-1023..1023)read-writecurrent
cmdExcRfIqAdjustBiasFineI
OBJECT-TYPE
Adjusts the offset for I in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.81Integer32 (-32767..32767)read-writecurrent
cmdExcRfIqAdjustBiasFineQ
OBJECT-TYPE
Adjusts the offset for Q in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.82Integer32 (-32767..32767)read-writecurrent
cmdExcRfIqAdjustGainI
OBJECT-TYPE
Adjusts the gain for I in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.83Integer32 (0..255)read-writecurrent
cmdExcRfIqAdjustGainQ
OBJECT-TYPE
Adjusts the gain for Q in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.84Integer32 (0..255)read-writecurrent
cmdExcRfIqAdjustPhase
OBJECT-TYPE
Adjusts the phase between I and Q (-14.000 ... 14.000).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.85FloatingPointread-writecurrent
cmdExcInput1Source
OBJECT-TYPE
Source for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.86InputSourceread-writecurrent
cmdExcInput2Source
OBJECT-TYPE
Source for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.87InputSourceread-writecurrent
cmdExcInpAutoReadyAfterChangeOv
OBJECT-TYPE
Input automatic ready after change over.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.88SwitchOnOffread-writecurrent
cmdExcInputFailDelayTime
OBJECT-TYPE
The time between detecting a loss of input signal and displaying a failure.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.89Integer32 (0..600)read-writecurrent
cmdExcTransmitterType
OBJECT-TYPE
the TV standard of the transmitter The transmitter is rebooted automatically when the TV standard is changed. Signal processing is also switched over.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.90INTEGER {atv(1), dvb(2), atsc(3)}read-writecurrent
cmdExcTimeScheduler
OBJECT-TYPE
If on, the time scheduler controls the tx type. When switching on the scheduler it may instantly set the correct TV standard and reboot the device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.91SwitchOnOffread-writecurrent
cmdExcMuteCondition
OBJECT-TYPE
When notBeforeSyncLoss(2) is selected, it relativizes the cmdExcInputMuteOnFail setting mute(1): If a DVB receiver is the last valid input, an existing transport stream, even if it is faulty shall not be muted. Only for SLx/Sx801
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.92INTEGER {onAllFaults(1), notBeforeSyncLoss(2)}read-writecurrent
cmdExcRfWarningLimit
OBJECT-TYPE
Warning limit for the RF control. min: -15.0, max: 0.0
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.97FloatingPointread-writecurrent
cmdExcRfFailLimit
OBJECT-TYPE
Fault limit for the RF control. min: -15.0, max: 0.0
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.98FloatingPointread-writecurrent
cmdExcOutputPower
OBJECT-TYPE
amplifier output power 0 ... 400 W
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.99FloatingPointread-writecurrent
cmdOstRefVoltageVision
OBJECT-TYPE
This adjusts the output power of the amplifier. This value is settable with maximal 1 position after point (example 11.2).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.100FloatingPointread-writecurrent
cmdOstMaxOutletTempThreshold
OBJECT-TYPE
This sets the threshold for the outlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.101Integer32 (45..65)read-writecurrent
cmdExcMonitoringOutput
OBJECT-TYPE
Selects which signal appears at the monitoring output.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.110INTEGER {off(1), reference10MHz(2), generated1PPS(3), kHz1(4), pulse1PPS(5)}read-writecurrent
cmdExcOcxoAdjust
OBJECT-TYPE
Adjusts the frequency of the internal 10 MHz reference. This value only takes effect if the reference source 'internal' is selected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.111Integer32 (0..65535)read-writecurrent
cmdExcExpectInputReserve
OBJECT-TYPE
If on(1) the warning txExcInputReseveMissing will be generated in case second input is missing.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.112SwitchOnOffread-writecurrent
cmdExcEnablePcrReset
OBJECT-TYPE
Enables/disables daily PCR resets. This option is valid only in MFN operation. The reset time is given in cmdExcTimeForDailyPcrReset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.113SwitchOnOffread-writeobsolete
cmdExcTimeForDailyPcrReset
OBJECT-TYPE
Sets the time of day for daily PCR reset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.114TimeOfDayread-writeobsolete
cmdExcFailDelayMode
OBJECT-TYPE
Condition when the fail delay time is used.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.115FailDelayModeread-writecurrent
summaryInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.1.2
summaryFaultTx
OBJECT-TYPE
This indicates a summary fault of the transmitter. true(1) --> summary fault false(2) --> no summary fault There is a fault of at least one module (e.g. Exciter) which causes this summary fault. An equivalent would be the LED Fault at the transmitters frontpanel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.1TruthValueread-onlycurrent
summaryWarningTx
OBJECT-TYPE
This indicates a summary warning of the transmitter. true(1) --> summary warning false(2) --> no summary warning There is a fault of at least one module (e.g. Exciter) which causes this summary warning. An equivalent would be the LED Warning at the transmitters frontpanel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.2TruthValueread-onlycurrent
localModeTx
OBJECT-TYPE
This indicates the local/remote-mode of the transmitter. true(1) --> local false(2) --> remote The transmitter is eigther in local-mode or in remote-mode. For security reasons it is not possible to set this value! An equivalent would the LED Local at the transmitters frontpanel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.3TruthValueread-onlycurrent
rfOnTx
OBJECT-TYPE
The RF is present for the corresponding transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.4TruthValueread-onlycurrent
forwardPower
OBJECT-TYPE
The measured forwarded power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.5FloatingPointread-onlycurrent
reflectedPower
OBJECT-TYPE
The measured reflected power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.6FloatingPointread-onlycurrent
summaryFaultExcA
OBJECT-TYPE
This indicates a summary fault of exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.7TruthValueread-onlycurrent
summaryFaultOstA
OBJECT-TYPE
This indicates a summary fault of outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.8TruthValueread-onlycurrent
summaryFaultExcB
OBJECT-TYPE
This indicates a summary fault of exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.9TruthValueread-onlycurrent
summaryFaultOstB
OBJECT-TYPE
This indicates a summary fault of outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.10TruthValueread-onlycurrent
exciterAutomaticReady
OBJECT-TYPE
The Exciter Automatic is Ready. In case of any fault on one exciter, there will be a switchover to the other exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.11TruthValueread-onlycurrent
exciterAutomaticChanged
OBJECT-TYPE
The Exciter Automatic has changed. There was a fault on one exciter which lead to this changeover.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.12TruthValueread-onlycurrent
exciterAutomaticFault
OBJECT-TYPE
The Exciter Automatic is faulty. In case of any fault on one exciter, there will be no switchover to the other exciter, because of this fault.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.13TruthValueread-onlycurrent
outputstageAutomaticReady
OBJECT-TYPE
The Outputstage Automatic is Ready. In case of any fault on one outputstage, there will be a switchover to the other outputstage. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.14TruthValueread-onlycurrent
outputstageAutomaticChanged
OBJECT-TYPE
The Outputstage Automatic has changed. There was a fault on one outputstage which lead to this changeover. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.15TruthValueread-onlycurrent
outputstageAutomaticFault
OBJECT-TYPE
The Outputstage Automatic is faulty. In case of any fault on one outputstage, there will be no switchover to the other outputstage, because of this fault. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.16TruthValueread-onlycurrent
noConnectionExcA
OBJECT-TYPE
No Connection between NetCCU and Exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.17TruthValueread-onlycurrent
noConnectionOstA
OBJECT-TYPE
No Connection between NetCCU and Outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.18TruthValueread-onlycurrent
noConnectionExcB
OBJECT-TYPE
No Connection between NetCCU and Exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.19TruthValueread-onlycurrent
noConnectionOstB
OBJECT-TYPE
No Connection between NetCCU and Outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.20TruthValueread-onlycurrent
activeExcA
OBJECT-TYPE
ExciterA is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.21TruthValueread-onlycurrent
activeOstA
OBJECT-TYPE
OutputstageA is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.22TruthValueread-onlycurrent
activeExcB
OBJECT-TYPE
ExciterB is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.23TruthValueread-onlycurrent
activeOstB
OBJECT-TYPE
OutputstageB is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.24TruthValueread-onlycurrent
forwardPowerOstA
OBJECT-TYPE
The measured forwarded power [W] of the OutputstageA.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.25FloatingPointread-onlycurrent
reflectedPowerOstA
OBJECT-TYPE
The measured reflected power [W] of the OutputstageA. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.26FloatingPointread-onlycurrent
forwardPowerOstB
OBJECT-TYPE
The measured forwarded power [W] of the OutputstageB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.27FloatingPointread-onlycurrent
reflectedPowerOstB
OBJECT-TYPE
The measured reflected power [W] of the OutputstageB. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.28FloatingPointread-onlycurrent
powerSupply
OBJECT-TYPE
Monitoring value of the output voltages of the power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.29FloatingPointread-onlycurrent
additionalPowerSupply
OBJECT-TYPE
Shows whether the NetCCU has an additional (external) power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.30TruthValueread-onlycurrent
internalPowerSupply
OBJECT-TYPE
Monitoring value of the output voltages of the internal power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.31FloatingPointread-onlycurrent
externalPowerSupply
OBJECT-TYPE
Monitoring value of the output voltages of the external power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.32FloatingPointread-onlycurrent
detailedInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.1.3
excInputTable
OBJECT-TYPE
A table for more detailed information about the exciter. These values are all read-only. For settings, refer to commands.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2not-accessiblecurrent
excInputEntry
OBJECT-TYPE
An entry for a designated input channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1not-accessiblecurrent
excInputExcIdx
OBJECT-TYPE
The index for exciterA (and exciterB if there are DualDrive systems).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.1IndexABnot-accessiblecurrent
excInputChannelIdx
OBJECT-TYPE
The index for the different input channels.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.2Integer32 (1..6)not-accessiblecurrent
excInputChannelName
OBJECT-TYPE
This is the logical name for the index for the different input channels.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.3INTEGER {hp1(1), hp2(2), lp1(3), lp2(4), activeHP(5), activeLP(6)}read-onlycurrent
excInputConnected
OBJECT-TYPE
The input channel is connected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.4TruthValueread-onlycurrent
excInputSeamless
OBJECT-TYPE
The input channel is in seamless mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.5TruthValueread-onlycurrent
excInputPreselected
OBJECT-TYPE
The input channel is the preselected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.6TruthValueread-onlycurrent
excInputActive
OBJECT-TYPE
The input channel is active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.7TruthValueread-onlycurrent
excInputMipFail
OBJECT-TYPE
Input channel MIP fail.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.8TruthValueread-onlycurrent
excInputBandwidth
OBJECT-TYPE
The bandwidth used by the input channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.9INTEGER {mhz5(1), mhz6(2), mhz7(3), mhz8(4)}read-onlycurrent
excInputFFTLength
OBJECT-TYPE
The used FFT length (depends on the DVB network).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.10INTEGER {k2(1), k8(2), k4(3)}read-onlycurrent
excInputGuardInterval
OBJECT-TYPE
The Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.11INTEGER {oneOf32(1), oneOf16(2), oneOf8(3), oneOf4(4)}read-onlycurrent
excInputConstellation
OBJECT-TYPE
This parameter sets the modulation mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.12INTEGER {qpsk(1), qam16(2), qam64(3)}read-onlycurrent
excInputAlpha
OBJECT-TYPE
An alpha greater than zero enables the hierarchical coding mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.13INTEGER {noHierarchy(1), one(2), two(3), four(4)}read-onlyobsolete
excInputCellID
OBJECT-TYPE
Via Cell ID the receiver knows the current network.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.14Integer32 (0..65535)read-onlycurrent
excInputInterleaver
OBJECT-TYPE
Enables the bit interleaver for hierarchical coding
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.15INTEGER {indepth(1), nat(2)}read-onlycurrent
excInputCodeRate
OBJECT-TYPE
Coderate can be set separately for HP and LP channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.16INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)}read-onlycurrent
excInputPacketLength
OBJECT-TYPE
The Packet length for the channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.17Integer32 (188..208)read-onlycurrent
excInputMeasuredDatarate
OBJECT-TYPE
The measured datarate of the input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.18Integer32read-onlycurrent
excInputRequiredDatarate
OBJECT-TYPE
The required datarate of the input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.19Integer32read-onlycurrent
excInputMaximumDelay
OBJECT-TYPE
Period of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inserter and serves as a basis for all the transmitters in the SFN.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.20Integer32 (0..100000000)read-onlycurrent
ostTable
OBJECT-TYPE
The table of racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3not-accessiblecurrent
ostEntry
OBJECT-TYPE
A row (an entry) for one rack.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1not-accessiblecurrent
ostIdx
OBJECT-TYPE
The dedicated outputstage (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.1IndexABnot-accessiblecurrent
ostRackIdx
OBJECT-TYPE
The rack number (1..10).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.2IndexRacknot-accessiblecurrent
ostRackInletTemperature
OBJECT-TYPE
The inlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.3FloatingPointread-onlycurrent
ostRackOutletTemperature
OBJECT-TYPE
The outlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.4FloatingPointread-onlycurrent
ostRackAuxPowerSupply
OBJECT-TYPE
Control voltage of auxiliary power supply of the designated rack. The value should be between 11.1 to 13.2 V.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.5FloatingPointread-onlycurrent
ostRackAmpIdx
OBJECT-TYPE
Amplifier Index
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.400IndexAmplifiernot-accessiblecurrent
ostRackAmpI1A
OBJECT-TYPE
The power amplifier module current (I_1A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.401FloatingPointread-onlycurrent
ostRackAmpI2A
OBJECT-TYPE
The power amplifier module current (I_2A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.402FloatingPointread-onlycurrent
ostRackAmpI3A
OBJECT-TYPE
The power amplifier module current (I_3A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.403FloatingPointread-onlycurrent
ostRackAmpI4A
OBJECT-TYPE
The power amplifier module current (I_4A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.404FloatingPointread-onlycurrent
ostRackAmpI1B
OBJECT-TYPE
The power amplifier module current (I_1B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.405FloatingPointread-onlycurrent
ostRackAmpI2B
OBJECT-TYPE
The power amplifier module current (I_2B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.406FloatingPointread-onlycurrent
ostRackAmpI3B
OBJECT-TYPE
The power amplifier module current (I_3B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.407FloatingPointread-onlycurrent
ostRackAmpI4B
OBJECT-TYPE
The power amplifier module current (I_4B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.408FloatingPointread-onlycurrent
ostRackAmpIDrv
OBJECT-TYPE
The driver module current (I_DRV).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.409FloatingPointread-onlycurrent
ostRackAmpUDc
OBJECT-TYPE
The power amplifier supply voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.410FloatingPointread-onlycurrent
ostRackAmpIDc
OBJECT-TYPE
The power amplifier supply current.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.411FloatingPointread-onlycurrent
ostRackAmpUDcControl
OBJECT-TYPE
The power supply control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.412FloatingPointread-onlycurrent
ostRackAmpUReg
OBJECT-TYPE
The power amplifier AGC voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.413FloatingPointread-onlycurrent
ostRackAmpPowerA
OBJECT-TYPE
The voltage power detector A.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.414FloatingPointread-onlycurrent
ostRackAmpPowerB
OBJECT-TYPE
The voltage power detector B.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.415FloatingPointread-onlycurrent
ostRackAmpPowerOut
OBJECT-TYPE
The voltage forward power detector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.416FloatingPointread-onlycurrent
ostRackAmpPowerReflection
OBJECT-TYPE
The voltage reflected power detector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.417FloatingPointread-onlycurrent
ostRackAmpPowerReference
OBJECT-TYPE
The reference voltage for output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.418FloatingPointread-onlycurrent
ostRackAmpDeltaPhase
OBJECT-TYPE
The measured phase delta for output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.419FloatingPointread-onlycurrent
ostRackAmpCmdDeltaPhase
OBJECT-TYPE
The phase delta setting for output power. The range is -50.0% to 50.0%.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.420FloatingPointread-writecurrent
exciterStatusTable
OBJECT-TYPE
Exciter status values.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20not-accessiblecurrent
exciterStatusEntry
OBJECT-TYPE
A row (an entry) for one exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1not-accessiblecurrent
excStatusExcIdx
OBJECT-TYPE
The dedicated exciter (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.3IndexABnot-accessiblecurrent
excStatusRfOutputAgcRegulation
OBJECT-TYPE
Shows the operating point of the RF regulator. The shown value should be around 50 per cent.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.4FloatingPointread-onlycurrent
excStatusRfIqAdjustAuto
OBJECT-TYPE
Automatic I/Q-Adjust.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.5INTEGER {notAdjusted(1), inProgress(2), adjusted(3)}read-onlycurrent
excStatusRfIqAdjustLO1Frequency
OBJECT-TYPE
Modulator LO1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.6FloatingPointread-onlycurrent
excStatusNominalPower
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.7Integer32read-writecurrent
excStatusVSWR
OBJECT-TYPE
Voltage Standing Wave Ratio
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.9FloatingPointread-onlycurrent
excStatusSfnDelayProcessing
OBJECT-TYPE
The Minimum signal transmit time through the exciter. This delay depends on the DVB transmission parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.13FloatingPointread-onlycurrent
excStatusSfnDelayDynamic
OBJECT-TYPE
The period of time by which signal processing is artificially delayed so that the desired time of transmission is obtained.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.14FloatingPointread-onlycurrent
excStatusSfnDelayNetwork
OBJECT-TYPE
The signal propagation time between the play-out center (MIP inserter) and the exciter input. This delay depends on the transmission path used.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.15FloatingPointread-onlycurrent
excStatusSfnDelayTxOffset
OBJECT-TYPE
An individual transmitter specific delay. It can be adjusted via data carousel of the SFN adapter. It is true for a specific transmitter address.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.16FloatingPointread-onlycurrent
excStatusSfnDelayMaximum
OBJECT-TYPE
The period of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inserter and serves as a basis for all the transmitters in the SFN.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.17FloatingPointread-onlycurrent
excStatusSfnDelayTotal
OBJECT-TYPE
The actual signal transit time through the exciter. This is derived from the sum of static-, dynamic-, offset- and processing delay.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.18FloatingPointread-onlycurrent
excStatusAmplifierControl
OBJECT-TYPE
Amplifier control status
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.20INTEGER {on(1), off(2)}read-onlycurrent
excStatusReqDataRateHP
OBJECT-TYPE
Required data rate on HP input with respect to the current TPS settings.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.30Integer32read-onlycurrent
excStatusReqDataRateLP
OBJECT-TYPE
Required data rate on LP input with respect to the current TPS settings.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.31Integer32read-onlycurrent
excStatusFailDelay
OBJECT-TYPE
Shows whether the fail delay time is qualified.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.40FailDelayStatusread-onlycurrent
exciterPrecorrectionTable
OBJECT-TYPE
Exciter status values.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21not-accessiblecurrent
exciterPrecorrectionEntry
OBJECT-TYPE
A row (an entry) for one exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1not-accessiblecurrent
excPrecExcIdx
OBJECT-TYPE
The dedicated exciter (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.3IndexABnot-accessiblecurrent
excPrecLinCorrection
OBJECT-TYPE
Switches on/turns off the linear precorrector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.4SwitchOnOffread-writecurrent
excPrecLinAutomaticADE
OBJECT-TYPE
Enables /disables the automatic precorrector. To get the ADE in work linear precorrection has to be switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.5INTEGER {manual(1), automatic(2), adaptive(3)}read-writecurrent
excPrecLinMaxAmplitudeRipple
OBJECT-TYPE
Sets te maximum ripple for automatic amplitude correction (0.0 ... 2.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.6FloatingPointread-writecurrent
excPrecLinMaxGroupDelayRipple
OBJECT-TYPE
Sets the maximum ripple for automatic group delay correction.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.7Integer32 (0..500)read-writecurrent
excPrecLinAmplitudeRipple
OBJECT-TYPE
Shows the current amplitude ripple.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.8FloatingPointread-onlycurrent
excPrecLinGroupDelayRipple
OBJECT-TYPE
Shows the current group delay ripple.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.9Integer32read-onlycurrent
excPrecLinInputLevel
OBJECT-TYPE
Shows the state of the feedback signal from the measurement point between output stage and antenna.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.10INTEGER {tooHigh(1), ok(2), tooLow(3), failure(4)}read-onlycurrent
excPrecLinAutomatic
OBJECT-TYPE
Shows if the automatic precorrector works properly.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.11INTEGER {disabled(1), active(2), calculate(3), measure(4)}read-onlycurrent
excPrecNonlinCorrection
OBJECT-TYPE
Switches on/turns off the nonlinear precorrector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.12SwitchOnOffread-writecurrent
excPrecNonlinAutomaticADE
OBJECT-TYPE
Enables /disables the automatic precorrector. To get the ADE in work nonlinear precorrection has to be switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.13INTEGER {manual(1), automatic(2), adaptive(3)}read-writecurrent
excPrecNonlinThresholdShoulders
OBJECT-TYPE
The target shoulder distance for ADE (0.0 ... 40.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.14FloatingPointread-writecurrent
excPrecNonlinShoulderLeft
OBJECT-TYPE
Displays the current measurement for the left handed shoulder distance.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.15FloatingPointread-onlycurrent
excPrecNonlinShoulderRight
OBJECT-TYPE
Displays the current measurement of the right handed shoulder.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.16FloatingPointread-onlycurrent
excPrecNonlinInputLevel
OBJECT-TYPE
Shows the state of the feedback signal from the measurement point between output stage and antenna.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.17INTEGER {tooHigh(1), ok(2), tooLow(3), failure(4)}read-onlycurrent
excPrecNonlinAutomatic
OBJECT-TYPE
Shows if the automatic precorrector works properly.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.18INTEGER {disabled(1), active(2), calculate(3), measure(4)}read-onlycurrent
excPrecUserState
OBJECT-TYPE
status of the user precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.100EqualizerCalibrationStateread-onlycurrent
excPrecFactoryState
OBJECT-TYPE
status of the factory precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.101EqualizerCalibrationStateread-onlycurrent
excPrecRestoreCurrentSettings
OBJECT-TYPE
restores current factory precorrection setting
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.102INTEGER {stop(1), start(2)}read-writecurrent
excPrecRestoreAllSettings
OBJECT-TYPE
restores all factory precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.103INTEGER {stop(1), start(2)}read-writecurrent
configurationTable
OBJECT-TYPE
Table for Type Configuration parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30not-accessiblecurrent
configurationEntry
OBJECT-TYPE
An entry for the Type Configuration parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1not-accessiblecurrent
configTvStandardIdx
OBJECT-TYPE
The index for the TV standard.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.3TvStandardnot-accessiblecurrent
configTvStandardName
OBJECT-TYPE
The name of the TV standard as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.5TvStandardread-onlycurrent
configRxFrequency
OBJECT-TYPE
The input frequency for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.6Integer32 (160000000..910000000)read-writecurrent
configFrequency
OBJECT-TYPE
The output frequency for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.7Integer32 (47000000..1500000000)read-writecurrent
configPower
OBJECT-TYPE
The output power (0.0 ... 2500.0) for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.8FloatingPointread-writecurrent
configInputSource
OBJECT-TYPE
The source for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.9InputSourceread-writecurrent
timeSchedulerTable
OBJECT-TYPE
Table for Time Scheduler parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31not-accessiblecurrent
timeSchedulerEntry
OBJECT-TYPE
An entry in the table for the Time Scheduler parameters. A row in this table is created by setting the value of schedulerRowStatus to 'createAndGo' or 'createAndWait'. A row in this table is deleted by setting the value of schedulerRowStatus to 'destroy'.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1not-accessiblecurrent
schedulerDateTimeIdx
OBJECT-TYPE
The DateAndTime index. Note: Deci-seconds different from 0 and UTC values are ignored. The index is implemented as a Fixed length string of 8 components. The last component (Deci-seconds) is always 0. Example: The DateTime of 2008-9-15,17:45:30.0 has the index: 7.216.9.15.17.45.30.0
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.3DateAndTimenot-accessiblecurrent
schedulerRowStatus
OBJECT-TYPE
This object is used to create and delete rows in the timeSchedulerTable.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.5RowStatusread-createcurrent
schedulerEvent
OBJECT-TYPE
The event type.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.6INTEGER {daily(1), once(2)}read-createcurrent
schedulerDateTime
OBJECT-TYPE
The start date and the time of a daily or one-time event.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.7DateAndTimeread-onlycurrent
schedulerTvStandard
OBJECT-TYPE
The TV standard.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.8TvStandardread-createcurrent
configuration2Table
OBJECT-TYPE
Table for Type Configuration parameters of input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32not-accessiblecurrent
configuration2Entry
OBJECT-TYPE
An entry for the Type Configuration parameters of input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1not-accessiblecurrent
config2TvStandardName
OBJECT-TYPE
The name of the TV standard as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.5TvStandardread-onlycurrent
config2RxFrequency
OBJECT-TYPE
The input frequency for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.6Integer32 (160000000..910000000)read-writecurrent
config2Frequency
OBJECT-TYPE
The output frequency for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.7Integer32 (47000000..1500000000)read-writecurrent
config2Power
OBJECT-TYPE
The output power (0.0 ... 2500.0) for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.8FloatingPointread-writecurrent
config2InputSource
OBJECT-TYPE
The source for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.9InputSourceread-writecurrent
productInfoTable
OBJECT-TYPE
The table for product typeplates.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100not-accessiblecurrent
productInfoEntry
OBJECT-TYPE
A row (an entry) for one typeplate.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1not-accessiblecurrent
prodInfoModuleIdx
OBJECT-TYPE
The module index.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.1ProdInfoModuleNameTvnot-accessiblecurrent
prodInfoDeviceIdx
OBJECT-TYPE
The dedicated device (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.2IndexABnot-accessiblecurrent
prodInfoRackIdx
OBJECT-TYPE
The rack number (1..10).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.3IndexRacknot-accessiblecurrent
prodInfoAmpIdx
OBJECT-TYPE
Amplifier Index
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.4IndexAmplifiernot-accessiblecurrent
prodInfoModuleName
OBJECT-TYPE
The name of the module as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.5ProdInfoModuleNameTvread-onlycurrent
prodInfoSerialNumber
OBJECT-TYPE
The serial number of the subdevice.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.6ReadableStringread-onlycurrent
prodInfoIdentNumberSW
OBJECT-TYPE
The Rohde&Schwarz identification number of the software, for example 2094.2090.02.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.7ReadableStringread-onlycurrent
prodInfoVersionNumberSW
OBJECT-TYPE
The Rohde&Schwarz revision number of the software, for example 1.2.1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.8ReadableStringread-onlycurrent
prodInfoIdentNumberHW
OBJECT-TYPE
The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.9ReadableStringread-onlycurrent
prodInfoVersionNumberHW
OBJECT-TYPE
The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.10ReadableStringread-onlycurrent
productInfoProductDateHW
OBJECT-TYPE
The Rohde&Schwarz production date of the hardware,
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.11DateAndTimeread-onlycurrent
logbook
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.1.4
netCCUNumberOfEntries
OBJECT-TYPE
The number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.1LogbookMaxEntryNumberread-onlycurrent
netCCULogbookClear
OBJECT-TYPE
Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.2Triggerread-writecurrent
netCCULogbookTable
OBJECT-TYPE
NetCCU logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3not-accessiblecurrent
netCCULogbookEntry
OBJECT-TYPE
This is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1not-accessiblecurrent
netCCULogbookEntryIdx
OBJECT-TYPE
This is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.1LogbookMaxEntryNumbernot-accessiblecurrent
netCCULogbookEntryNbr
OBJECT-TYPE
This is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.2LogbookMaxEntryNumberread-onlycurrent
netCCULogbookType
OBJECT-TYPE
Can either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.3EventClassread-onlycurrent
netCCULogbookSlope
OBJECT-TYPE
Either set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.4LogbookEntrySloperead-onlycurrent
netCCULogbookMessage
OBJECT-TYPE
See RS-XX8000-COMMON-MIB - TextualConvention - LogbookEntryMessagesNetCCU for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.5LogbookEntryMessagesNetCCUread-onlycurrent
netCCULogbookDateTime
OBJECT-TYPE
netCCULogbookDateTime
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.6DateAndTimeread-onlycurrent
exciterANumberOfEntries
OBJECT-TYPE
The number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.4LogbookMaxEntryNumberread-onlycurrent
exciterALogbookClear
OBJECT-TYPE
Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.5Triggerread-writecurrent
exciterALogbookTable
OBJECT-TYPE
ExciterA logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6not-accessiblecurrent
exciterALogbookEntry
OBJECT-TYPE
This is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1not-accessiblecurrent
excALogbookEntryIdx
OBJECT-TYPE
This is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.1LogbookMaxEntryNumbernot-accessiblecurrent
excALogbookEntryNbr
OBJECT-TYPE
This is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.2LogbookMaxEntryNumberread-onlycurrent
excALogbookType
OBJECT-TYPE
Can either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.3EventClassread-onlycurrent
excALogbookSlope
OBJECT-TYPE
Either set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.4LogbookEntrySloperead-onlycurrent
excALogbookMessage
OBJECT-TYPE
See RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.5LogbookEntryMessagesExcTvread-onlycurrent
excALogbookDateTime
OBJECT-TYPE
The time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.6DateAndTimeread-onlycurrent
outputstageANumberOfEntries
OBJECT-TYPE
The number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.7LogbookMaxEntryNumberread-onlycurrent
outputstageALogbookClear
OBJECT-TYPE
Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.8Triggerread-writecurrent
outputstageALogbookTable
OBJECT-TYPE
OutputstageA logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9not-accessiblecurrent
outputstageALogbookEntry
OBJECT-TYPE
This is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1not-accessiblecurrent
ostALogbookEntryIdx
OBJECT-TYPE
This is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.1LogbookMaxEntryNumbernot-accessiblecurrent
ostALogbookEntryNbr
OBJECT-TYPE
This is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.2LogbookMaxEntryNumberread-onlycurrent
ostALogbookType
OBJECT-TYPE
Can either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.3EventClassread-onlycurrent
ostALogbookSlope
OBJECT-TYPE
Either set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.4LogbookEntrySloperead-onlycurrent
ostALogbookMessage
OBJECT-TYPE
See RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.5LogbookEntryMessagesOSTread-onlycurrent
ostALogbookDateTime
OBJECT-TYPE
The time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.6DateAndTimeread-onlycurrent
exciterBNumberOfEntries
OBJECT-TYPE
The number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.10LogbookMaxEntryNumberread-onlycurrent
exciterBLogbookClear
OBJECT-TYPE
Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.11Triggerread-writecurrent
exciterBLogbookTable
OBJECT-TYPE
ExciterB logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12not-accessiblecurrent
exciterBLogbookEntry
OBJECT-TYPE
This is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1not-accessiblecurrent
excBLogbookEntryIdx
OBJECT-TYPE
This is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.1LogbookMaxEntryNumbernot-accessiblecurrent
excBLogbookEntryNbr
OBJECT-TYPE
This is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.2LogbookMaxEntryNumberread-onlycurrent
excBLogbookType
OBJECT-TYPE
Can either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.3EventClassread-onlycurrent
excBLogbookSlope
OBJECT-TYPE
Either set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.4LogbookEntrySloperead-onlycurrent
excBLogbookMessage
OBJECT-TYPE
See RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.5LogbookEntryMessagesExcTvread-onlycurrent
excBLogbookDateTime
OBJECT-TYPE
The time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.6DateAndTimeread-onlycurrent
outputstageBNumberOfEntries
OBJECT-TYPE
The number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.13LogbookMaxEntryNumberread-onlycurrent
outputstageBLogbookClear
OBJECT-TYPE
Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.14Triggerread-writecurrent
outputstageBLogbookTable
OBJECT-TYPE
OutputstageB logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15not-accessiblecurrent
outputstageBLogbookEntry
OBJECT-TYPE
This is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1not-accessiblecurrent
ostBLogbookEntryIdx
OBJECT-TYPE
This is an increasing number from 1 to 128. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.1LogbookMaxEntryNumbernot-accessiblecurrent
ostBLogbookEntryNbr
OBJECT-TYPE
This is the number of the logbook entry. It is an decreasing number from max 128 down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.2LogbookMaxEntryNumberread-onlycurrent
ostBLogbookType
OBJECT-TYPE
Can either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.3EventClassread-onlycurrent
ostBLogbookSlope
OBJECT-TYPE
Either set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.4LogbookEntrySloperead-onlycurrent
ostBLogbookMessage
OBJECT-TYPE
See RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.5LogbookEntryMessagesOSTread-onlycurrent
ostBLogbookDateTime
OBJECT-TYPE
The time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.6DateAndTimeread-onlycurrent
rfProbesTable
OBJECT-TYPE
This table contains all commands for the RF probes.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5not-accessiblecurrent
rfProbesEntry
OBJECT-TYPE
An entry for a designated transmitter and device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1not-accessiblecurrent
rfProbesNetCCURfProbe1
OBJECT-TYPE
Current voltage on RF Probe 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.1FloatingPointread-onlycurrent
rfProbesNetCCURfProbe2
OBJECT-TYPE
Current voltage on RF Probe 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.2FloatingPointread-onlycurrent
rfProbesAntFwdNominal
OBJECT-TYPE
This sets the nominal value [W] of the transmitter (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.3FloatingPointread-writecurrent
rfProbesAntFwdWarningLimit
OBJECT-TYPE
This sets the warning limit for the transmitters RF control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.4FloatingPointread-writecurrent
rfProbesAntFwdFailLimit
OBJECT-TYPE
This sets the fault limit for the transmitters RF control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.5FloatingPointread-writecurrent
rfProbesAntFwdDelayTimeRfFail
OBJECT-TYPE
This sets the delay time for the RF Fail control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.6Integer32 (1..20)read-writecurrent
rfProbesAntFwdSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.7Triggerread-writecurrent
rfProbesAntFwdSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.8Triggerread-writecurrent
rfProbesAntReflWarningLimit
OBJECT-TYPE
This sets the warning limit for the transmitters reflection control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.9FloatingPointread-writecurrent
rfProbesAntReflSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.10Triggerread-writecurrent
rfProbesAntReflSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.11Triggerread-writecurrent
rfProbesDLFwdNominal
OBJECT-TYPE
This sets the nominal value [W] of the transmitter (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.12FloatingPointread-writecurrent
rfProbesDLFwdWarningLimit
OBJECT-TYPE
This sets the warning limit for the transmitters RF control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.13FloatingPointread-writecurrent
rfProbesDLFwdFailLimit
OBJECT-TYPE
This sets the fault limit for the transmitters RF control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.14FloatingPointread-writecurrent
rfProbesDLFwdDelayTimeRfFail
OBJECT-TYPE
This sets the delay time for the RF Fail control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.15Integer32 (1..20)read-writecurrent
rfProbesDLFwdSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.16Triggerread-writecurrent
rfProbesDLFwdSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.17Triggerread-writecurrent
rfProbesDLReflWarningLimit
OBJECT-TYPE
This sets the warning limit for the transmitters reflection control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.18FloatingPointread-writecurrent
rfProbesDLReflSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.19Triggerread-writecurrent
rfProbesDLReflSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.20Triggerread-writecurrent
rfProbesOstIdx
OBJECT-TYPE
The dedicated outputstage (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.21IndexABnot-accessiblecurrent
rfProbesOstFwdNominal
OBJECT-TYPE
This sets the nominal value [W] of the outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.22FloatingPointread-writecurrent
rfProbesOstFwdWarningLimit
OBJECT-TYPE
This sets the warning limit for the outputstage RF control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.23FloatingPointread-writecurrent
rfProbesOstFwdFailLimit
OBJECT-TYPE
This sets the fault limit for the outputstage RF control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.24FloatingPointread-writecurrent
rfProbesOstFwdDelayTimeRfFail
OBJECT-TYPE
This sets the delay time for the outputstage RF Fail control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.25Integer32 (1..20)read-writecurrent
rfProbesOstFwdSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.26Triggerread-writecurrent
rfProbesOstFwdSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.27Triggerread-writecurrent
rfProbesOstReflWarningLimit
OBJECT-TYPE
This sets the warning limit for the outputstage reflection control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.28FloatingPointread-writecurrent
rfProbesOstReflSetOffset
OBJECT-TYPE
This triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.29Triggerread-writecurrent
rfProbesOstReflSetGain
OBJECT-TYPE
This triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.30Triggerread-writecurrent
rackTable
OBJECT-TYPE
This table contains important commands for the racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6not-accessiblecurrent
rackEntry
OBJECT-TYPE
An entry for a designated rack or rack's rf probe.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1not-accessiblecurrent
ostDeviceIdx
OBJECT-TYPE
The index to address outputstageA and outputstageB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.2IndexABnot-accessiblecurrent
rackIdx
OBJECT-TYPE
The index to address the racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.3IndexRacknot-accessiblecurrent
rackRfProbeIdx
OBJECT-TYPE
The index to address forward and reflected RF probes. For not RF probe parameters this index is always 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.4INTEGER {forward(1), reflected(2)}not-accessiblecurrent
amplifiersPerRack
OBJECT-TYPE
The number of amplifiers of a rack.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.6Integer32 (1..10)read-onlycurrent
rackRfEventSignalling
OBJECT-TYPE
This configures whether to signal rf events or not.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.7TruthValueread-writecurrent
rackReferenceVoltage
OBJECT-TYPE
This parameter controls the reference voltage (31.0 ... 100.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.8FloatingPointread-writecurrent
amplifiersPowerSupply
OBJECT-TYPE
This parameter controls the power supplies of the amplifier within the rack (31.0 ... 100.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.9FloatingPointread-writecurrent
rackGeneralPurposeInput
OBJECT-TYPE
Setting of the general purpose input behaviour.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.10INTEGER {unused(1), doorOpen(2), extCoolingWarning(3), extCoolingFault(4)}read-writecurrent
rackOnOff
OBJECT-TYPE
This switches the rack on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.20SwitchOnOffread-writecurrent
rfProbePresent
OBJECT-TYPE
If the RF probe of this rack is present.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.50TruthValueread-onlycurrent
rfProbeConfigurationLabel
OBJECT-TYPE
Name for the measured signal on RF Probe.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.51ReadableString (SIZE(0..12))read-writeobsolete
rfProbeConfigurationNominalValue
OBJECT-TYPE
The nominal value of the measured signal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.52Integer32 (0..100000)read-writecurrent
rfProbeThresholdRfFailLimit
OBJECT-TYPE
Fault limit for the RF control (-20.0 ... 0.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.55FloatingPointread-writecurrent
rfProbeThresholdTimeoutRfFailCtr
OBJECT-TYPE
Timeout for RF Fail Control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.56Integer32 (1..20)read-writecurrent
rfProbeThresholdWarningLimit
OBJECT-TYPE
Warning limit for the RF control (-20.0 ... 0.0). For reflected probes: Warning limit for the reflection control. This limit is added to the fault limit to generate the real warning limit; e.g. the fault limit is -17.0dB and the warning limit is -3.0dB, so the warning is active on a reflected power higher than -20.0 dB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.57FloatingPointread-writecurrent
rfProbeCalibrationGain
OBJECT-TYPE
Measured value of gain calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.60FloatingPointread-onlycurrent
rfProbeCalibrationOffset
OBJECT-TYPE
Measured value of offset calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.61FloatingPointread-onlycurrent
rfProbeCalibrationSetGain
OBJECT-TYPE
Sets the gain calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.62Triggerread-writecurrent
rfProbeCalibrationSetOffset
OBJECT-TYPE
Sets the offset calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.63Triggerread-writecurrent
rfProbeMeasuredValue
OBJECT-TYPE
Measured forward/reflected power of antenna signal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.65FloatingPointread-onlycurrent
sx801AmplifierTable
OBJECT-TYPE
Amplifier status values for SX801 amplifiers.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7not-accessiblecurrent
sx801AmplifierEntry
OBJECT-TYPE
A row (an entry) for one amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1not-accessiblecurrent
sx801AmpIdx
OBJECT-TYPE
The amplifier index.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.1IndexAmplifiernot-accessiblecurrent
sx801AmpRfOut
OBJECT-TYPE
Shows if the amplifier generates an RF or not. off(1): The amplifier output is switched off e.g. because the amplifier gets no input signal or the transmitter has been switched off warning(2): There is an RF but its level is less than the RF warning limit. ok(3): The RF level is greater than the RF warning limit.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.2Sx801AmplifierStateread-onlycurrent
sx801AmpRfIn
OBJECT-TYPE
Displays the state of the amplifier input. off(1): no input signal detected warning(2): the level of the input signal is too low or too high. ok(3): input signal is OK.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.3Sx801AmplifierStateread-onlycurrent
sx801AmpReflection
OBJECT-TYPE
A reflection on RF output of this Amplifier module has been detected. This leads to a reduction of output power of the amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.4INTEGER {off(1), warning(2), unknown(3), fault(4)}read-onlycurrent
sx801AmpOn
OBJECT-TYPE
Shows if the amplifier has been switched on by the control unit.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.5INTEGER {off(1), on(3), unknown(4)}read-onlycurrent
sx801AmpAC
OBJECT-TYPE
Shows the state of primary voltage of the power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.6Sx801AmplifierStateread-onlycurrent
sx801AmpCommunication
OBJECT-TYPE
Displays if the CAN communication between amplifier and Sx801 is working or not.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.7INTEGER {off(1), unknown(2), ok(3), fault(4)}read-onlycurrent
sx801AmpTransistor
OBJECT-TYPE
A transistor fail is displayed here. For further information please see the amplifiers service menue.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.8Sx801AmplifierStateread-onlycurrent
sx801AmpDriver
OBJECT-TYPE
Shows a failure if one of the internal driver transistors does not work properly. For further information please see the amplifiers service menue.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.9Sx801AmplifierStateread-onlycurrent
sx801AmpTemperature
OBJECT-TYPE
Shows a fault if the temperature of amplifier module is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.10Sx801AmplifierStateread-onlycurrent
sx801AmpBlower
OBJECT-TYPE
Displays the state of the internal blowers.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.11Sx801AmplifierStateread-onlycurrent
sx801AmpRegulation
OBJECT-TYPE
Shows a fault if the amplifier is not able to control its output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.12Sx801AmplifierStateread-onlycurrent
sx801AmpUpdate
OBJECT-TYPE
Firmware update is in progress. This will be started automatically during a software update procedure of the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.13TruthValueread-onlycurrent
sx801Supply1Temperature
OBJECT-TYPE
Shows a fault if the temperature of power supply one is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.14Sx801AmplifierStateread-onlycurrent
sx801Supply2Temperature
OBJECT-TYPE
Shows a fault if the temperature of power supply two is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.15Sx801AmplifierStateread-onlycurrent
sx801SupplyRTemperature
OBJECT-TYPE
Shows a fault if the temperature of the reserve power supply is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.16Sx801AmplifierStateread-onlycurrent
sx801Supply1DC
OBJECT-TYPE
Shows a fault if the output voltage of power supply one is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.17Sx801AmplifierStateread-onlycurrent
sx801Supply2DC
OBJECT-TYPE
Shows a fault if the output voltage of power supply two is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.18Sx801AmplifierStateread-onlycurrent
sx801SupplyRDC
OBJECT-TYPE
Shows a fault if the output voltage of the reserve power supply is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.19Sx801AmplifierStateread-onlycurrent
sx801AmpValueI1
OBJECT-TYPE
The internal current from transistor pair 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.50FloatingPointread-onlycurrent
sx801AmpValueI2
OBJECT-TYPE
The internal current from transistor pair 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.51FloatingPointread-onlycurrent
sx801AmpValueI3
OBJECT-TYPE
The internal current from transistor pair 3.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.52FloatingPointread-onlycurrent
sx801AmpValueI4
OBJECT-TYPE
The internal current from transistor pair 4.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.53FloatingPointread-onlycurrent
sx801AmpValueIPre
OBJECT-TYPE
The internal current from preamplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.54FloatingPointread-onlycurrent
sx801AmpValueIDrv1
OBJECT-TYPE
The internal current from driver transistor pair 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.55FloatingPointread-onlycurrent
sx801AmpValueIDrv2
OBJECT-TYPE
The internal current from driver transistor pair 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.56FloatingPointread-onlycurrent
sx801AmpValuePowerOut
OBJECT-TYPE
The base value in Volt to calculate the output power of this amplifier module.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.57FloatingPointread-onlycurrent
sx801AmpValueReflection
OBJECT-TYPE
The base value in Volt for detection of reflections.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.58FloatingPointread-onlycurrent
sx801AmpValueVRef
OBJECT-TYPE
The internal reference voltage to set the output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.59FloatingPointread-onlycurrent
sx801AmpValueVReg
OBJECT-TYPE
The internal value for output power regulation.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.60FloatingPointread-onlycurrent
sx801AmpValueTemperature
OBJECT-TYPE
The internal temperature of Amplifier. In case of L-band amplifier, the shown temperature is valid only, if the amplifier is switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.61FloatingPointread-onlycurrent
sx801AmpValueMonAtt
OBJECT-TYPE
The attenuation of monitoring output on the front of the amplifier module (Amp RF Mon).
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.62FloatingPointread-onlycurrent
sx801AmpValueVAux1
OBJECT-TYPE
The voltage power detector 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.63FloatingPointread-onlycurrent
sx801AmpValueVAux2
OBJECT-TYPE
The voltage power detector 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.64FloatingPointread-onlycurrent
sx801Supply1ValuePwr
OBJECT-TYPE
The power supply one control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.65FloatingPointread-onlycurrent
sx801Supply2ValuePwr
OBJECT-TYPE
The power supply two control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.66FloatingPointread-onlycurrent
sx801Supply1ValueDc
OBJECT-TYPE
The internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply one.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.67FloatingPointread-onlycurrent
sx801Supply2ValueDc
OBJECT-TYPE
The internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply two.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.68FloatingPointread-onlycurrent
rsXx8000DvbTxEvents
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.3
eventTx
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.3.2
eventsTxV2
OBJECT-IDENTITY
Compatibility to SMIv1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0current
eventsTxTable
OBJECT-TYPE
This table contains necessary information for handling alarms. For each alarm you have the following information: - name (get), - mask to enable/disable sending out (set/get), - priority (set/get) and - the current state (get only).
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1not-accessiblecurrent
eventsTxEntry
OBJECT-TYPE
An event entry always consists of its indexes (used for addressing within redundancy systems) and 3 values: - name: an enumerated list of all possible notifications - mask: the corresponding mask (enable/disable) - priority: the corresponding priority (value in range 0..255) - event: the event itself (active/inactive)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1not-accessiblecurrent
eventTxABIdx
OBJECT-TYPE
The value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) for alarms. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.1INTEGER {a(1), b(2)}not-accessiblecurrent
eventTxRackIdx
OBJECT-TYPE
The number of the designated rack. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.2Integer32 (1..10)not-accessiblecurrent
eventTxAmpIdx
OBJECT-TYPE
The number of the designated amplifier. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.3Integer32 (1..10)not-accessiblecurrent
eventTxNameIdx
OBJECT-TYPE
The event number as integer. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.4EventMaxEntryNumbernot-accessiblecurrent
eventTxName
OBJECT-TYPE
The event number as integer and the value as readable text. The enumeration correlates with the notifications under eventsTxV2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.5INTEGER {txSummaryFault(1), txSummaryWarning(2), txLocal(3), txRfOn(4), txRfOk(5), txParamSetSubDeviceDiffers(6), txParamSetValuesChanged(7), txRfLoopProgram(8), txRfLoopReserve(9), txRfWarning(10), txReflectionWarning(11), txNetCCUFanFault(12), txNetCCUPowerSupply(13), txRfFail(14), txReflectionFault(15), txNetCCUBoardTemperatureFault(16), txNetCCUNoConnectionToExcA(17), txNetCCUNoConnectionToOstA(18), txNetCCUNoConnectionToExcB(19), txNetCCUNoConnectionToOstB(20), txAutomaticExcReady(21), txAutomaticExcChanged(22), txAutomaticExcFault(23), txAutomaticOstReady(24), txAutomaticOstChanged(25), txAutomaticOstFault(26), txNetCCUBoardTemperatureWarning(27), txInternalPowerSupplyWarning(30), txExternalPowerSupplyWarning(31), txModeSwitchOverStarted(35), txModeSwitchOverEnded(36), txModeInconsistent(37), txModeSwitchOverFailed(38), txExcSummaryFault(100), txExcSummaryWarning(101), txExcLocal(102), txExcRfOk(104), txExcInputNoConnectHP1(105), txExcInputNoConnectLP1(106), txExcInputNoConnectHP2(107), txExcInputNoConnectLP2(108), txExcInputActiveHP1(109), txExcInputActiveLP1(110), txExcInputActiveHP2(111), txExcInputActiveLP2(112), txExcOn(113), txExcRfOn(114), txExcNoInput(115), txExcRfLoop(116), txExcRfFail(117), txExcSelfTest(118), txExcOutputOpen(119), txExcBoardTemperatureWarning(120), txExcFanWarning(121), txExcFanFault(122), txExcFifoWarning(123), txExcTestSignal(124), txExcSFNDelay(125), txExcWrongDatarate(126), txExcMute(127), txExcPPSFail(128), txExcReferenceFail(129), txExcMIPFail(130), txExcInputAutomaticSwitchReady(131), txExcInputAutomaticChangedOver(132), txExcInputReseveMissing(133), txOstSummaryFault(200), txOstSummaryWarning(201), txOstRfOn(202), txOstRfOk(203), txOstNoInput(204), txOstRfWarning(205), txOstReflectionWarning(206), txOstRackWarning(207), txOstCoolingWarning(208), txOstRfFail(209), txOstReflectionFault(210), txOstACFault(211), txOstCoolingFault(212), txOstCommFault(213), txRackSumFault(300), txRackSumWarning(301), txRackOn(302), txRackGpiWarning(303), txRackFan1Fault(304), txRackFan2Fault(305), txRackCoolingSumWarning(306), txRackAmplifierSumFault(307), txRackNoLink(308), txRackGpiFault(309), txRackTemperatureFault(310), txRackACFault(311), txRackCoolingSumFault(312), txRackTempFaultAbs1(313), txRackTempFaultAbs2(314), txRackDCFault(315), txRackRfOn(318), txRackRfOk(319), txRackRfWarning(320), txRackRfFault(321), txRackReflectionWarning(322), txRackReflectionFault(323), txRackProbeNotCalibrated(330), txRackTemperatureWarning(331), txRackOvervoltProtectWarning(335), txAmpSumFault(400), txAmpSumWarning(401), txAmpPowerOn(402), txAmpDCOk(403), txAmpACOk(404), txAmpRfInFail(405), txAmpRfFail(406), txAmpReflectionFault(407), txAmpTemperatureFault(408), txAmpTransistorFault(409)}read-onlycurrent
eventTxMask
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.6EventMaskread-writecurrent
eventTxPriority
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.7EventPriorityread-writecurrent
eventTxEvent
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.8EventStateread-onlycurrent
rsXx8000DvbTxConf
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.5
rsXx8000DvbTxGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.5.1
rsXx8000DvbTxCompl
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.4.5.3

Notifications

NameOIDStatus
txSummaryFault
NOTIFICATION-TYPE
Transmitter Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.1current
txSummaryWarning
NOTIFICATION-TYPE
Transmitter Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.2current
txLocal
NOTIFICATION-TYPE
Transmitter Local/Remote
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.3current
txRfOn
NOTIFICATION-TYPE
Transmitter RF On/Off
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.4current
txRfOk
NOTIFICATION-TYPE
Transmitter RF Ok / Not OK
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.5current
txParamSetSubDeviceDiffers
NOTIFICATION-TYPE
Parameterset of subdevice is different. The currently loaded parameterset is inconsistent because a subdevice (e.g. an exciter) has a different configuration than expected. To correct this, save settings to the current or save a complete new.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.6obsolete
txParamSetValuesChanged
NOTIFICATION-TYPE
Value Of Current Parameterset Changed. The currently loaded parameterset is inconsistent because there were changes happening since the load/save of it. To correct this, save settings to the current or save a complete new.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.7current
txRfLoopProgram
NOTIFICATION-TYPE
NetCCU Loop Program
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.8current
txRfLoopReserve
NOTIFICATION-TYPE
NetCCU Loop Reserve
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.9current
txRfWarning
NOTIFICATION-TYPE
NetCCU RF Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.10current
txReflectionWarning
NOTIFICATION-TYPE
NetCCU Reflection Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.11current
txNetCCUFanFault
NOTIFICATION-TYPE
NetCCU Fan Fault. This is valid, if Fan Control is switched on (see menu NetCCU Setup - Common).
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.12current
txNetCCUPowerSupply
NOTIFICATION-TYPE
NetCCU Power Supply
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.13current
txRfFail
NOTIFICATION-TYPE
NetCCU RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.14current
txReflectionFault
NOTIFICATION-TYPE
NetCCU Reflection Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.15current
txNetCCUBoardTemperatureFault
NOTIFICATION-TYPE
NetCCU Board Temperature Fault deprecated: this information is now handled as a warning (txNetCCUBoardTemperatureWarning)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.16deprecated
txNetCCUNoConnectionToExcA
NOTIFICATION-TYPE
NetCCU Connection To ExciterA Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.17current
txNetCCUNoConnectionToOstA
NOTIFICATION-TYPE
NetCCU Connection To OutputstageA Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.18current
txNetCCUNoConnectionToExcB
NOTIFICATION-TYPE
NetCCU Connection To ExciterB Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.19current
txNetCCUNoConnectionToOstB
NOTIFICATION-TYPE
NetCCU Connection To OutputstageB Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.20current
txAutomaticExcReady
NOTIFICATION-TYPE
Exciter Automatic Ready.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.21current
txAutomaticExcChanged
NOTIFICATION-TYPE
Exciter Automatic Changed.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.22current
txAutomaticExcFault
NOTIFICATION-TYPE
Exciter Automatic Fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.23current
txAutomaticOstReady
NOTIFICATION-TYPE
Outputstage Automatic Ready. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.24current
txAutomaticOstChanged
NOTIFICATION-TYPE
Outputstage Automatic Changed. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.25current
txAutomaticOstFault
NOTIFICATION-TYPE
Outputstage Automatic Fault. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.26current
txNetCCUBoardTemperatureWarning
NOTIFICATION-TYPE
NetCCU Board Temperature Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.27current
txInternalPowerSupplyWarning
NOTIFICATION-TYPE
NetCCU internal Power Supply warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.30current
txExternalPowerSupplyWarning
NOTIFICATION-TYPE
NetCCU external (additional) Power Supply warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.31current
txModeSwitchOverStarted
NOTIFICATION-TYPE
Switch over of TX mode started.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.35current
txModeSwitchOverEnded
NOTIFICATION-TYPE
Switch over of TX mode ended.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.36current
txModeInconsistent
NOTIFICATION-TYPE
An inconsistency in configuration of TX mode was detected. The CCU and exiter configurations are incompatible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.37current
txModeSwitchOverFailed
NOTIFICATION-TYPE
Switch over of TX mode failed. Please check whether the configurations of CCU and exciter are correct.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.38current
txExcSummaryFault
NOTIFICATION-TYPE
Exciter Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.100current
txExcSummaryWarning
NOTIFICATION-TYPE
Exciter Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.101current
txExcLocal
NOTIFICATION-TYPE
Exciter Local/Remote
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.102current
txExcRfOk
NOTIFICATION-TYPE
Exciter RF Ok
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.104current
txExcInputNoConnectHP1
NOTIFICATION-TYPE
Exciter Input HP1 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.105current
txExcInputNoConnectLP1
NOTIFICATION-TYPE
Exciter Input LP1 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.106current
txExcInputNoConnectHP2
NOTIFICATION-TYPE
Exciter Input HP2 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.107current
txExcInputNoConnectLP2
NOTIFICATION-TYPE
Exciter Input LP2 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.108current
txExcInputActiveHP1
NOTIFICATION-TYPE
Exciter Input HP1 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.109current
txExcInputActiveLP1
NOTIFICATION-TYPE
Exciter Input LP1 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.110current
txExcInputActiveHP2
NOTIFICATION-TYPE
Exciter Input HP2 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.111current
txExcInputActiveLP2
NOTIFICATION-TYPE
Exciter Input LP2 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.112current
txExcOn
NOTIFICATION-TYPE
Exciter On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.113current
txExcRfOn
NOTIFICATION-TYPE
Exciter RF On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.114current
txExcNoInput
NOTIFICATION-TYPE
Exciter has no valid input signal.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.115current
txExcRfLoop
NOTIFICATION-TYPE
Exciter RF loop
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.116current
txExcRfFail
NOTIFICATION-TYPE
Exciter RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.117current
txExcSelfTest
NOTIFICATION-TYPE
Exciter hardware self test
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.118current
txExcOutputOpen
NOTIFICATION-TYPE
Exciter output open
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.119current
txExcBoardTemperatureWarning
NOTIFICATION-TYPE
Exciter Board Temperature
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.120current
txExcFanWarning
NOTIFICATION-TYPE
Exciter has one faulty fan
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.121current
txExcFanFault
NOTIFICATION-TYPE
Both exciter fans are faulty.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.122current
txExcFifoWarning
NOTIFICATION-TYPE
Exciter Fifo
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.123current
txExcTestSignal
NOTIFICATION-TYPE
Exciter Testsignal Active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.124current
txExcSFNDelay
NOTIFICATION-TYPE
Exciter SFN Delay Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.125current
txExcWrongDatarate
NOTIFICATION-TYPE
Exciter Wrong Datarate
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.126current
txExcMute
NOTIFICATION-TYPE
Exciter Mute
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.127current
txExcPPSFail
NOTIFICATION-TYPE
Exciter PPS Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.128current
txExcReferenceFail
NOTIFICATION-TYPE
Exciter Reference Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.129current
txExcMIPFail
NOTIFICATION-TYPE
Exciter MIP Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.130current
txExcInputAutomaticSwitchReady
NOTIFICATION-TYPE
Input automatic is ready.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.131current
txExcInputAutomaticChangedOver
NOTIFICATION-TYPE
Input automatic changed over.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.132current
txExcInputReseveMissing
NOTIFICATION-TYPE
Missing input, or automatic switching enabled with only one input present. Disable automatic switching or press reset fault to remove this warning. Monitoring of a second input will start automatically if two input signals have been detected. This event will be generated only if cmdExcExpectInputReserve is set to on(1).
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.133current
txOstSummaryFault
NOTIFICATION-TYPE
Outputstage Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.200current
txOstSummaryWarning
NOTIFICATION-TYPE
Outputstage Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.201current
txOstRfOn
NOTIFICATION-TYPE
Outputstage RF On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.202current
txOstRfOk
NOTIFICATION-TYPE
Outputstage RF Ok
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.203current
txOstNoInput
NOTIFICATION-TYPE
Outputstage no input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.204current
txOstRfWarning
NOTIFICATION-TYPE
Outputstage RF Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.205current
txOstReflectionWarning
NOTIFICATION-TYPE
Outputstage Reflection Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.206current
txOstRackWarning
NOTIFICATION-TYPE
Outputstage Rack Warning. At least one rack has an error pending.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.207current
txOstCoolingWarning
NOTIFICATION-TYPE
Outputstage Cooling Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.208current
txOstRfFail
NOTIFICATION-TYPE
Outputstage RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.209current
txOstReflectionFault
NOTIFICATION-TYPE
Outputstage Reflection Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.210current
txOstACFault
NOTIFICATION-TYPE
Outputstage AC Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.211current
txOstCoolingFault
NOTIFICATION-TYPE
Outputstage Cooling Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.212current
txOstCommFault
NOTIFICATION-TYPE
Outputstage Communication Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.213current
txRackSumFault
NOTIFICATION-TYPE
Summary Fault at a designated rack. This event automatically leads to txOstRackWarning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.300current
txRackSumWarning
NOTIFICATION-TYPE
Summary Warning at a designated rack.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.301current
txRackOn
NOTIFICATION-TYPE
The designated racks operation mode is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.302current
txRackGpiWarning
NOTIFICATION-TYPE
A warning on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.303current
txRackFan1Fault
NOTIFICATION-TYPE
The designated rack signals a fault of fan 1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.304current
txRackFan2Fault
NOTIFICATION-TYPE
The designated rack signals a fault of fan 2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.305current
txRackCoolingSumWarning
NOTIFICATION-TYPE
The designated rack signals a summary cooling warning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.306current
txRackAmplifierSumFault
NOTIFICATION-TYPE
The designated rack signals at least one faulty amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.307current
txRackGpiFault
NOTIFICATION-TYPE
A fault on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.309current
txRackTemperatureFault
NOTIFICATION-TYPE
The designated rack signals a temperature fault - temperature too high.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.310current
txRackACFault
NOTIFICATION-TYPE
The designated rack signals an AC (phase) fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.311current
txRackCoolingSumFault
NOTIFICATION-TYPE
The designated rack signals a summary cooling fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.312current
txRackTempFaultAbs1
NOTIFICATION-TYPE
The designated rack signals a temperature fault of absorber 1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.313current
txRackTempFaultAbs2
NOTIFICATION-TYPE
The designated rack signals a temperature fault of absorber 2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.314current
txRackDCFault
NOTIFICATION-TYPE
The designated rack signals a DC fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.315current
txRackRfOn
NOTIFICATION-TYPE
RF power is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.318current
txRackRfOk
NOTIFICATION-TYPE
RF power is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.319current
txRackRfWarning
NOTIFICATION-TYPE
RF power decreased the warning threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.320current
txRackRfFault
NOTIFICATION-TYPE
RF output power decreased the fault threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.321current
txRackReflectionWarning
NOTIFICATION-TYPE
The reflected power increased the warning threshold
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.322current
txRackReflectionFault
NOTIFICATION-TYPE
The reflected power increased the fault threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.323current
txRackProbeNotCalibrated
NOTIFICATION-TYPE
At least one probe is not calibrated.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.330current
txRackTemperatureWarning
NOTIFICATION-TYPE
Rack temperature exceeded the warning threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.331current
txRackOvervoltProtectWarning
NOTIFICATION-TYPE
Overvoltage protection is out of order.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.335current
txAmpSumFault
NOTIFICATION-TYPE
The designated amplifier signals summary fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.400current
txAmpSumWarning
NOTIFICATION-TYPE
The designated amplifier signals summary warning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.401current
txAmpPowerOn
NOTIFICATION-TYPE
The designated amplifiers power is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.402current
txAmpDCOk
NOTIFICATION-TYPE
The designated amplifiers DC is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.403current
txAmpACOk
NOTIFICATION-TYPE
The designated amplifiers AC is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.404current
txAmpRfInFail
NOTIFICATION-TYPE
The designated amplifier signals RF input fail.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.405current
txAmpRfFail
NOTIFICATION-TYPE
The designated amplifier signals RF fail.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.406current
txAmpReflectionFault
NOTIFICATION-TYPE
The designated amplifier signals a reflection fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.407current
txAmpTemperatureFault
NOTIFICATION-TYPE
The designated amplifier signals a temperature fault - temperature is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.408current
txAmpTransistorFault
NOTIFICATION-TYPE
The designated amplifier signals at least one faulty transistor.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.409current

Conformance

NameOIDStatus
groupEvents
OBJECT-GROUP
This group includes all OIDs for event handling.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.1current
groupTxCommon
OBJECT-GROUP
Group for common transmitter objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.2current
groupEventsTxCommon
NOTIFICATION-GROUP
This group includes all alarm OIDs that are common for all reserve concepts.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.3current
groupDualDrive
OBJECT-GROUP
This group includes additional objects for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.4current
groupEventsDualDrive
NOTIFICATION-GROUP
This group includes additional events for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.5current
groupPowerReserve
OBJECT-GROUP
This group includes additional objects for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.6current
groupEventsPowerReserve
NOTIFICATION-GROUP
This group includes additional events for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.7current
groupCommonMP
OBJECT-GROUP
additional objects for medium/high power
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.8current
groupEventsCommonMP
NOTIFICATION-GROUP
additional events for medium/high power
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.9current
groupCommonNetCCU
OBJECT-GROUP
additional objects for transmitters with NetCCU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.10current
groupEventsCommonNetCCU
NOTIFICATION-GROUP
additional events for transmitters with NetCCU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.11current
groupOstBLogbook
OBJECT-GROUP
objects of logbook for output stage B
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.12current
groupSumProbe
OBJECT-GROUP
objects that are available only when sum probe exists
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.14current
groupProductInfo
OBJECT-GROUP
This group includes all OIDs for device product information.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.18current
groupAmpMeasureValues
OBJECT-GROUP
This group includes all OIDs amplifier measure values. Practically, these information are not important to customers, they are needed in manufactory.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.19current
groupEventsAmplifier
NOTIFICATION-GROUP
events from the amplifier (medium/high power only)
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.20current
groupRfProbes
OBJECT-GROUP
This group includes all OIDs regarding RF Probes.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.21current
groupDummyLoadRF
OBJECT-GROUP
This group includes all object types regarding probes from dummy load. The object types in this group are defined only when a dummy load measure point exists. This can occur in reserve concept active reserve only.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.22current
groupExcCommon
OBJECT-GROUP
Group for common exciter objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.23current
groupExcAdditionalSx800
OBJECT-GROUP
Additional exciter objects for the Sx800
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.24current
groupExcAdditionalSLx
OBJECT-GROUP
Additional exciter objects for the SLx and the Sx801
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.25current
groupEventsExciter
NOTIFICATION-GROUP
events from the exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.26current
groupExciterStatus
OBJECT-GROUP
Group for exciterStatusTable.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.27current
groupExciterPrecorrection
OBJECT-GROUP
Group for exciterPrecorrectionTable.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.28current
groupSLx
OBJECT-GROUP
object types that are relevant for SLx devices only
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.29current
groupObjectsACU
OBJECT-GROUP
objects from ACU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.30current
groupIndependentRacks
OBJECT-GROUP
object types that are relevant for NX variants with independent racks only
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.31current
groupObjectsRE
OBJECT-GROUP
object types for the re-equip kit
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.32current
groupEventsControlExciter
NOTIFICATION-GROUP
additional events in case Sx801 is control exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.34current
groupEventsAdditionalPowerSupply
NOTIFICATION-GROUP
Events that are available only when additionalPowerSupply is true.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.35current
groupObjsAdditionalPowerSupply
OBJECT-GROUP
Objects that are available only when additionalPowerSupply is true.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.36current
groupObjectsControlExciter
OBJECT-GROUP
additional objects in case Sx801 is control exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.37current
groupObjectsSingleEnded
OBJECT-GROUP
Group for objects in case of SingleTx or DualDrive.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.38current
groupObjectsSx801Amplifier
OBJECT-GROUP
Objects for Sx801/SA801 amplifier status.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.39current
groupObsoleted
OBJECT-GROUP
obsoleted or deprecated objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.99obsolete
groupEventsObsoleted
NOTIFICATION-GROUP
obsoleted or deprecated events
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.100obsolete
rsXx8000DVBSingleTxMP
MODULE-COMPLIANCE
Reserve concept SingleTransmitter for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.1current
rsXx8000DVBDualDriveMP
MODULE-COMPLIANCE
Reserve concept DualDrive for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.2current
rsXx8000DVBPowerReserveMP
MODULE-COMPLIANCE
Reserve concept Active/Passive Reserve for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.3current
rsXx8000DVBSingleTxLP
MODULE-COMPLIANCE
Reserve concept Low Power SingleTransmitter with NetCCU, meaning there is a NetCCU and a LowPower exciter with one or more (to the exciter) connected amplifiers.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.5current
rsXx8000DVBDualDriveLP
MODULE-COMPLIANCE
Reserve concept DualDrive for Low Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.6current
rsXx8000DVBPowerReserveLP
MODULE-COMPLIANCE
Reserve concept Active/Passive Reserve for Low Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.7current
rsXx8000DVBSingleTxLPNoNetCCU
MODULE-COMPLIANCE
Reserve concept Low Power SingleTransmitter without NetCCU, meaning there is only a LowPower exciter with one or more (to the exciter) connected amplifiers.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.9current
rsXx8000DVBSLx
MODULE-COMPLIANCE
SLx device
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.10current
rsXx8000DVBExciterOnly
MODULE-COMPLIANCE
DVB Exciter of 8000 series in a 7000 environment or Program Exciter in a Sx801 Backup Exciter environment.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.11current
rsXx8000DVBSx801ControlExciter
MODULE-COMPLIANCE
Sx801 as control exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.12current