RS-XX8000-DVB-TX-MIB
- Registered at
- 1.3.6.1.4.1.2566.127.1.2.167.41.3.6.1.4.1.2566.149.1.163.3
- Last updated
- 2012-11-01 08:00
- Organization
- Rohde&Schwarz GmbH & Co. KG
- Revisions
- 2012-11-01 08:00, 2012-09-03 08:00, 2011-05-12 08:00, 2011-02-28 08:00, 2010-12-02 08:00, 2010-10-13 08:00, 2010-05-21 08:00, 2010-04-16 08:00, 2010-02-02 08:00, 2010-01-29 08:00, 2010-01-12 08:00, 2009-12-18 08:00, 2009-11-26 08:00, 2009-11-13 08:00, 2009-10-08 08:00, 2009-09-10 08:00, 2009-07-16 08:00, 2009-06-26 08:00, 2009-06-17 09:00, 2009-05-28 09:00, 2009-03-30 09:00, 2009-02-12 15:00, 2009-01-29 09:00, 2009-01-06 16:00, 2008-12-12 14:30, 2008-10-23 08:00, 2008-10-08 10:30, 2008-09-10 15:00, 2008-08-29 10:00, 2008-08-26 09:00, 2008-07-23 10:00, 2008-05-05 09:30, 2008-03-31 11:00, 2007-12-07 17:00, 2007-09-10 11:00, 2007-08-09 14:00, 2007-07-11 16:00, 2007-03-08 10:00, 2006-12-21 10:00
- Namespace
- rs
- Source file
RS-XX8000-DVB-TX-MIB- Digest
sha256:ecf89d7ebe944ef8a761f2638e6d65a5d075a67a42d77f1efc71d7e90a90e758
Description
This MIB defines transmitting systems from Rohde & Schwarz. Use this MIB if your system meets the following requirements: - series XX8000 (NetCCU800), - DVB, - transmitter reserve concept SingleTx, DualDrive, Active Reserve or Passive Reserve. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB - RS-XX8000-COMMON-MIB - mandatory for this MIB
Contact
Torsten Huebscher Department 7TS2 Broadcasting Division Muehldorfstrasse 15 81671 Munich, Germany torsten.huebscher@rohde-schwarz.com
Imports
| From | Symbols |
|---|---|
| RS-XX8000-COMMON-MIB | EqualizerCalibrationState, EventClass, EventMask, EventMaxEntryNumber, EventPriority, EventState, FailDelayMode, FailDelayStatus, FloatingPoint, IndexAB, IndexAmplifier, IndexRack, InputSource, LogbookEntryMessagesExcTv, LogbookEntryMessagesNetCCU, LogbookEntryMessagesOST, LogbookEntrySlope, LogbookMaxEntryNumber, ProdInfoModuleNameTv, ReadableString, SwitchOnOff, Sx801AmplifierState, TimeOfDay, Trigger, TvStandard, eventAlarmClass, eventAlarmPriority, eventEvent, indexAB, indexAmplifier, indexRack, rsXx8000, rsXx8000MibModule |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
RS-COMMON-MIB RS-XX8000-COMMON-MIB RS-XX8000-DVB-TX-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rsXx8000DvbTx OBJECT-IDENTITY Xx8000 DVB transmitter. | 1.3.6.1.4.1.2566.127.1.2.167.4 | current | ||
| rsXx8000DvbTxObjs OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.1 | |||
| commandsTxTable OBJECT-TYPE This table contains important commands for the transmitter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1 | not-accessible | current | |
| commandsTxEntry OBJECT-TYPE An entry for a designated transmitter and device. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1 | not-accessible | current | |
| cmdTxResetSumFault OBJECT-TYPE Reset all faults (in all modules) of the transmitter. You reset a designated transmitter (NetCCU, Exciters, Outputstages). An equivalent would be pressing RESET at this transmitters frontpanel. A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.1 | Trigger | read-write | current |
| cmdTxParametersetLoad OBJECT-TYPE This loads the desired parameter set. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.2 | Integer32 (1..8) | read-write | current |
| cmdTxParametersetSave OBJECT-TYPE This saves the current settings to a designated parameter set. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.3 | Integer32 (1..8) | read-write | current |
| cmdTxParametersetReSave OBJECT-TYPE This saves the changes to the current parameter set. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.4 | Trigger | read-write | obsolete |
| cmdTxOperationModeProgram OBJECT-TYPE This switches the program path of the transmitter on/off. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.5 | SwitchOnOff | read-write | current |
| cmdTxOperationModeReserve OBJECT-TYPE This switches the reserve path of the transmitter on/off. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.6 | SwitchOnOff | read-write | current |
| cmdTxOpModeExcAutomatic OBJECT-TYPE This switches the exciter automatic on/off. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.7 | SwitchOnOff | read-write | current |
| cmdTxOpModeOstAutomatic OBJECT-TYPE This switches the outputstage automatic on/off. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.8 | SwitchOnOff | read-write | current |
| cmdTxPreselectExciter OBJECT-TYPE This sets exciterA or exciterB to program path (antenna) of the transmitter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.9 | IndexAB | read-write | current |
| cmdTxPreselectOutputstage OBJECT-TYPE This sets - outputstageA or - outputstageB or - both to program path (antenna) of the transmitter, or it sets both to dummyload. The settings bothToAntenna(3) and bothToDummyLoad(4) are only settable for ActiveReserve systems. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.10 | INTEGER {outputstageA(1), outputstageB(2), bothToAntenna(3), bothToDummyLoad(4)} | read-write | current |
| cmdTxDelayTimeExcAutomatic OBJECT-TYPE This sets the exciter automatic delay time. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.11 | Integer32 (1..60) | read-write | current |
| cmdTxDelayTimeOstAutomatic OBJECT-TYPE This sets the outputstage automatic delay time. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.12 | Integer32 (1..60) | read-write | current |
| cmdTxRfSwitch OBJECT-TYPE RF switch for single-ended systems. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.13 | INTEGER {antenna(1), dummyLoad(2)} | read-write | current |
| cmdTxSystemMode OBJECT-TYPE This object gives you the possibility of switching the TV standard of a whole system with NetCCU with only one command. Not applicable for N+1 or NTx systems. The value 'test' cannot be written. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.15 | TvStandard | read-write | current |
| cmdTxProgramExciterPrio OBJECT-TYPE Enables/Disables priority usage of program exciter | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.20 | SwitchOnOff | read-write | current |
| cmdTxChangeOver OBJECT-TYPE Performs a change over | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.21 | Trigger | read-write | current |
| cmdTxSwitchPosition OBJECT-TYPE Shows the actual switch position. The program exciter is connected to input 1 (RF IN 1), the control exciter is connected to input 2 (RF IN 2) of the base amplifier. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.22 | INTEGER {undefined(1), controlExcOnAmp(2), programExcOnAmp(3)} | read-only | current |
| cmdDeviceIdx OBJECT-TYPE This column is used to show parameters for both exiters, if you have dualdrive transmitters. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.30 | IndexAB | not-accessible | current |
| cmdExcOpModeInputAutomatic OBJECT-TYPE Activates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be used instead. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.31 | SwitchOnOff | read-write | current |
| cmdExcPreselectInput OBJECT-TYPE This sets the preselection of a transmitters input. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.32 | INTEGER {input1(1), input2(2)} | read-write | current |
| cmdExcMode OBJECT-TYPE Switch between DVB-T and DVB-H. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.33 | INTEGER {dvbT(1), dvbH(2)} | read-write | current |
| cmdExcNetworkMode OBJECT-TYPE Switch between Single Frequency Networks (SFN) and Multiple Frequency Networks (MFN). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.34 | INTEGER {mfn(1), sfn(2)} | read-write | current |
| cmdExcTPSSource OBJECT-TYPE Transmitted TPS parameters can be adjusted manually inside the transmitter or automatically via MIP from the SFN adaptor. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.35 | INTEGER {manualPresets(1), mip(2)} | read-write | current |
| cmdExcEnableCellID OBJECT-TYPE This enables the Cell ID insertion. The length indicator will be adjusted. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.36 | SwitchOnOff | read-write | current |
| cmdExcTxAddress OBJECT-TYPE This is the unique address of the transmitter to reference specific settings in the MIP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.37 | Integer32 (0..65535) | read-write | current |
| cmdExcTxAutomatic OBJECT-TYPE This enables Tx specific parameters from the MIP data caroussel (e.g. time offset, frequency offset). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.38 | SwitchOnOff | read-write | current |
| cmdExcInputAutoSwitch OBJECT-TYPE Activates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be used instead. This object is deprecated. It's recommended to use cmdExcOpModeInputAutomatic instead. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.39 | SwitchOnOff | read-write | deprecated |
| cmdExcInputSeamless OBJECT-TYPE If the datastreams on both inputs are syncronised a seamless switch is possible. With this parameter the seamless switch can be suppressed to enable a check of the input automatic. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.40 | SwitchOnOff | read-write | current |
| cmdExcInputPriority OBJECT-TYPE Equal: There are no differences between both inputs. If a failure on the current input is detected it will be switched to the reserve input. It stays there until the reserve shows a failure. Prior: Whenever possible a certain input shall be used. If a failure is detected the reserve will be used as short as possible. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.41 | INTEGER {equal(1), prior(2)} | read-write | current |
| cmdExcInputCheckTimeForward OBJECT-TYPE This time has to elapse before the current input switches to the reserve input. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.42 | Integer32 (0..600) | read-write | current |
| cmdExcInputCheckTimeSwitchback OBJECT-TYPE This time has to elapse before the automatic switches back from the reserve to a preselected input. This value has no effect if the priority is set to equal. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.43 | Integer32 (0..600) | read-write | current |
| cmdExcInputMuteOnFail OBJECT-TYPE If a loss of input signal is detected, the exciter mutes. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.44 | INTEGER {mute(1), noMute(2)} | read-write | current |
| cmdExcInputManualPreseletionHP1 OBJECT-TYPE The data format of the input can be detected automatically or can be set manually to ASI or SMPTE. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.45 | INTEGER {auto(1), asi(2), smpte(3)} | read-write | current |
| cmdExcInputManualPreseletionHP2 OBJECT-TYPE The data format of the input can be detected automatically or can be set manually to ASI or SMPTE. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.46 | INTEGER {auto(1), asi(2), smpte(3)} | read-write | current |
| cmdExcInputManualPreseletionLP1 OBJECT-TYPE The data format of the input can be detected automatically or can be set manually to ASI or SMPTE. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.47 | INTEGER {auto(1), asi(2), smpte(3)} | read-write | current |
| cmdExcInputManualPreseletionLP2 OBJECT-TYPE The data format of the input can be detected automatically or can be set manually to ASI or SMPTE. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.48 | INTEGER {auto(1), asi(2), smpte(3)} | read-write | current |
| cmdExcTPSManualBandwidth OBJECT-TYPE The bandwidth used by the RF channel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.49 | INTEGER {mhz5(1), mhz6(2), mhz7(3), mhz8(4)} | read-write | current |
| cmdExcTPSManualFFTLength OBJECT-TYPE The used FFT length (depends on the DVB network). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.50 | INTEGER {k2(1), k8(2), k4(3)} | read-write | current |
| cmdExcTPSManualGuardInterval OBJECT-TYPE The Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.51 | INTEGER {oneOf32(1), oneOf16(2), oneOf8(3), oneOf4(4)} | read-write | current |
| cmdExcTPSManualConstellation OBJECT-TYPE This parameter sets the modulation mode. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.52 | INTEGER {qpsk(1), qam16(2), qam64(3)} | read-write | current |
| cmdExcTPSManualAlpha OBJECT-TYPE An alpha greater than noHierarchy(1) enables the hierarchical coding mode. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.53 | INTEGER {noHierarchy(1), one(2), two(3), four(4)} | read-write | obsolete |
| cmdExcTPSManualCellID OBJECT-TYPE Via Cell ID the receiver knows the current network. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.54 | Integer32 (0..65535) | read-write | current |
| cmdExcTPSManualInterleaver OBJECT-TYPE Enables the bit interleaver for hierarchical coding | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.55 | INTEGER {indepth(1), nat(2)} | read-write | current |
| cmdExcTPSManualCoderateHP OBJECT-TYPE The Code Rate sets the ratio between payload and error correction information. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.56 | INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)} | read-write | current |
| cmdExcTPSManualCoderateLP OBJECT-TYPE The Code Rate sets the ratio between payload and error correction information. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.57 | INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)} | read-write | current |
| cmdExcTPSManualTimeSlicingHP OBJECT-TYPE Enables the time slicing for hierarchical coding. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.58 | SwitchOnOff | read-write | current |
| cmdExcTPSManualTimeSlicingLP OBJECT-TYPE Enables the time slicing for hierarchical coding. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.59 | SwitchOnOff | read-write | current |
| cmdExcTPSManualFECHP OBJECT-TYPE Enables the forward error correction (FEC) for hierarchical coding. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.60 | SwitchOnOff | read-write | current |
| cmdExcTPSManualFECLP OBJECT-TYPE Enables the forward error correction (FEC) for hierarchical coding. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.61 | SwitchOnOff | read-write | current |
| cmdExcSFNStaticDelay OBJECT-TYPE A constant adjustable delay for tuning a SFN (-999999.9 ... 999999.9). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.62 | FloatingPoint | read-write | current |
| cmdExcSFNDeviationTime OBJECT-TYPE Leap In Time. This parameter sets the deviation in time when a readjustment of the dynamic delay is necessary. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.63 | Integer32 (1..100) | read-write | current |
| cmdExcFrequency OBJECT-TYPE This is the RF frequency. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.64 | Integer32 (47000000..1500000000) | read-write | current |
| cmdExcReferenceSource OBJECT-TYPE The Source of the reference signal. The value internGPS is not valid for SX800. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.65 | INTEGER {intern(1), extern5Mhz(2), extern10Mhz(3), extern1PPS(4), internGPS(5)} | read-write | current |
| cmdExcMuteOnPPSFail OBJECT-TYPE Select the behaviour if the external second pulse is not available. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.66 | INTEGER {off(1), onlyAtStartup(2), afterFailDelayTime(3)} | read-write | current |
| cmdExcMuteOnReferenceFail OBJECT-TYPE Select the behaviour if the external reference is not available. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.67 | INTEGER {off(1), onlyAtStartup(2), afterFailDelayTime(3)} | read-write | current |
| cmdExcRefFailDelayTime OBJECT-TYPE Adjusts the time after the RF will be muted in case of a reference problem. Zero hours means react immediately. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.68 | Integer32 (0..24) | read-write | current |
| cmdExcTypeLossOfInput OBJECT-TYPE If the input signal is lost, either a warning or a fault can be generated. If you select fault here, a switchover to the reserve exciter will be executed when input signal is lost. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.69 | INTEGER {warning(1), fault(2)} | read-write | current |
| cmdExcRfOutput OBJECT-TYPE Turns on/switches off the output signal. This switch takes the same effect as the switch on the frontpanel of the exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.70 | SwitchOnOff | read-write | current |
| cmdExcRfOutputRegulation OBJECT-TYPE Turns on/switches off the automatic output level regulation. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.71 | SwitchOnOff | read-write | current |
| cmdExcRfOutputManualRfLevel OBJECT-TYPE Adjusts the RF level (0.0 ... 100.0). The value relates to an attenuation of 0 dB. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.72 | FloatingPoint | read-write | current |
| cmdExcRfOutputAttenuation OBJECT-TYPE Activates internal attenuators to reduce the output level of the exciter. Adjustable in steps of 3 dB only. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.73 | Integer32 (0..9) | read-write | current |
| cmdExcRfOutputRfSlope OBJECT-TYPE Adjusts a slope in the RF signal (-50.0 ... 50.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.74 | FloatingPoint | read-write | current |
| cmdExcRfOutputModulationSlope OBJECT-TYPE Modulation slope (-50.0 ... 50.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.75 | FloatingPoint | read-write | current |
| cmdExcRfIqAdjustStart OBJECT-TYPE Starts the automatic IQ adjustment. It works for the current used local 1 frequency and lasts up to 5 minutes. In this time the output will be muted. During the adjustment no transmitter parameter shall be changed. Break will stop the automatic immediately. The IQ modulator looses its adjustment! Read values mean idle(1) and started(2). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.77 | INTEGER {break(1), start(2)} | read-write | current |
| cmdExcRfIqAdjustTestsignal OBJECT-TYPE Generates a test signal to adjust the IQ modulation. It is necessary to disconnect the rf-cable to the output stages. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.78 | SwitchOnOff | read-write | current |
| cmdExcRfIqAdjustBiasCoarseI OBJECT-TYPE Adjusts the offset for I in huge steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.79 | Integer32 (-1023..1023) | read-write | current |
| cmdExcRfIqAdjustBiasCoarseQ OBJECT-TYPE Adjusts the offset for Q in huge steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.80 | Integer32 (-1023..1023) | read-write | current |
| cmdExcRfIqAdjustBiasFineI OBJECT-TYPE Adjusts the offset for I in small steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.81 | Integer32 (-32767..32767) | read-write | current |
| cmdExcRfIqAdjustBiasFineQ OBJECT-TYPE Adjusts the offset for Q in small steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.82 | Integer32 (-32767..32767) | read-write | current |
| cmdExcRfIqAdjustGainI OBJECT-TYPE Adjusts the gain for I in small steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.83 | Integer32 (0..255) | read-write | current |
| cmdExcRfIqAdjustGainQ OBJECT-TYPE Adjusts the gain for Q in small steps. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.84 | Integer32 (0..255) | read-write | current |
| cmdExcRfIqAdjustPhase OBJECT-TYPE Adjusts the phase between I and Q (-14.000 ... 14.000). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.85 | FloatingPoint | read-write | current |
| cmdExcInput1Source OBJECT-TYPE Source for input 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.86 | InputSource | read-write | current |
| cmdExcInput2Source OBJECT-TYPE Source for input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.87 | InputSource | read-write | current |
| cmdExcInpAutoReadyAfterChangeOv OBJECT-TYPE Input automatic ready after change over. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.88 | SwitchOnOff | read-write | current |
| cmdExcInputFailDelayTime OBJECT-TYPE The time between detecting a loss of input signal and displaying a failure. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.89 | Integer32 (0..600) | read-write | current |
| cmdExcTransmitterType OBJECT-TYPE the TV standard of the transmitter The transmitter is rebooted automatically when the TV standard is changed. Signal processing is also switched over. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.90 | INTEGER {atv(1), dvb(2), atsc(3)} | read-write | current |
| cmdExcTimeScheduler OBJECT-TYPE If on, the time scheduler controls the tx type. When switching on the scheduler it may instantly set the correct TV standard and reboot the device. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.91 | SwitchOnOff | read-write | current |
| cmdExcMuteCondition OBJECT-TYPE When notBeforeSyncLoss(2) is selected, it relativizes the cmdExcInputMuteOnFail setting mute(1): If a DVB receiver is the last valid input, an existing transport stream, even if it is faulty shall not be muted. Only for SLx/Sx801 | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.92 | INTEGER {onAllFaults(1), notBeforeSyncLoss(2)} | read-write | current |
| cmdExcRfWarningLimit OBJECT-TYPE Warning limit for the RF control. min: -15.0, max: 0.0 | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.97 | FloatingPoint | read-write | current |
| cmdExcRfFailLimit OBJECT-TYPE Fault limit for the RF control. min: -15.0, max: 0.0 | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.98 | FloatingPoint | read-write | current |
| cmdExcOutputPower OBJECT-TYPE amplifier output power 0 ... 400 W | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.99 | FloatingPoint | read-write | current |
| cmdOstRefVoltageVision OBJECT-TYPE This adjusts the output power of the amplifier. This value is settable with maximal 1 position after point (example 11.2). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.100 | FloatingPoint | read-write | current |
| cmdOstMaxOutletTempThreshold OBJECT-TYPE This sets the threshold for the outlet temperature. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.101 | Integer32 (45..65) | read-write | current |
| cmdExcMonitoringOutput OBJECT-TYPE Selects which signal appears at the monitoring output. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.110 | INTEGER {off(1), reference10MHz(2), generated1PPS(3), kHz1(4), pulse1PPS(5)} | read-write | current |
| cmdExcOcxoAdjust OBJECT-TYPE Adjusts the frequency of the internal 10 MHz reference. This value only takes effect if the reference source 'internal' is selected. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.111 | Integer32 (0..65535) | read-write | current |
| cmdExcExpectInputReserve OBJECT-TYPE If on(1) the warning txExcInputReseveMissing will be generated in case second input is missing. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.112 | SwitchOnOff | read-write | current |
| cmdExcEnablePcrReset OBJECT-TYPE Enables/disables daily PCR resets. This option is valid only in MFN operation. The reset time is given in cmdExcTimeForDailyPcrReset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.113 | SwitchOnOff | read-write | obsolete |
| cmdExcTimeForDailyPcrReset OBJECT-TYPE Sets the time of day for daily PCR reset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.114 | TimeOfDay | read-write | obsolete |
| cmdExcFailDelayMode OBJECT-TYPE Condition when the fail delay time is used. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.115 | FailDelayMode | read-write | current |
| summaryInfo OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2 | |||
| summaryFaultTx OBJECT-TYPE This indicates a summary fault of the transmitter. true(1) --> summary fault false(2) --> no summary fault There is a fault of at least one module (e.g. Exciter) which causes this summary fault. An equivalent would be the LED Fault at the transmitters frontpanel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.1 | TruthValue | read-only | current |
| summaryWarningTx OBJECT-TYPE This indicates a summary warning of the transmitter. true(1) --> summary warning false(2) --> no summary warning There is a fault of at least one module (e.g. Exciter) which causes this summary warning. An equivalent would be the LED Warning at the transmitters frontpanel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.2 | TruthValue | read-only | current |
| localModeTx OBJECT-TYPE This indicates the local/remote-mode of the transmitter. true(1) --> local false(2) --> remote The transmitter is eigther in local-mode or in remote-mode. For security reasons it is not possible to set this value! An equivalent would the LED Local at the transmitters frontpanel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.3 | TruthValue | read-only | current |
| rfOnTx OBJECT-TYPE The RF is present for the corresponding transmitter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.4 | TruthValue | read-only | current |
| forwardPower OBJECT-TYPE The measured forwarded power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.5 | FloatingPoint | read-only | current |
| reflectedPower OBJECT-TYPE The measured reflected power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages. Not available for lowpower systems. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.6 | FloatingPoint | read-only | current |
| summaryFaultExcA OBJECT-TYPE This indicates a summary fault of exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.7 | TruthValue | read-only | current |
| summaryFaultOstA OBJECT-TYPE This indicates a summary fault of outputstage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.8 | TruthValue | read-only | current |
| summaryFaultExcB OBJECT-TYPE This indicates a summary fault of exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.9 | TruthValue | read-only | current |
| summaryFaultOstB OBJECT-TYPE This indicates a summary fault of outputstage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.10 | TruthValue | read-only | current |
| exciterAutomaticReady OBJECT-TYPE The Exciter Automatic is Ready. In case of any fault on one exciter, there will be a switchover to the other exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.11 | TruthValue | read-only | current |
| exciterAutomaticChanged OBJECT-TYPE The Exciter Automatic has changed. There was a fault on one exciter which lead to this changeover. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.12 | TruthValue | read-only | current |
| exciterAutomaticFault OBJECT-TYPE The Exciter Automatic is faulty. In case of any fault on one exciter, there will be no switchover to the other exciter, because of this fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.13 | TruthValue | read-only | current |
| outputstageAutomaticReady OBJECT-TYPE The Outputstage Automatic is Ready. In case of any fault on one outputstage, there will be a switchover to the other outputstage. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.14 | TruthValue | read-only | current |
| outputstageAutomaticChanged OBJECT-TYPE The Outputstage Automatic has changed. There was a fault on one outputstage which lead to this changeover. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.15 | TruthValue | read-only | current |
| outputstageAutomaticFault OBJECT-TYPE The Outputstage Automatic is faulty. In case of any fault on one outputstage, there will be no switchover to the other outputstage, because of this fault. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.16 | TruthValue | read-only | current |
| noConnectionExcA OBJECT-TYPE No Connection between NetCCU and Exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.17 | TruthValue | read-only | current |
| noConnectionOstA OBJECT-TYPE No Connection between NetCCU and Outputstage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.18 | TruthValue | read-only | current |
| noConnectionExcB OBJECT-TYPE No Connection between NetCCU and Exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.19 | TruthValue | read-only | current |
| noConnectionOstB OBJECT-TYPE No Connection between NetCCU and Outputstage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.20 | TruthValue | read-only | current |
| activeExcA OBJECT-TYPE ExciterA is currently active. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.21 | TruthValue | read-only | current |
| activeOstA OBJECT-TYPE OutputstageA is currently active. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.22 | TruthValue | read-only | current |
| activeExcB OBJECT-TYPE ExciterB is currently active. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.23 | TruthValue | read-only | current |
| activeOstB OBJECT-TYPE OutputstageB is currently active. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.24 | TruthValue | read-only | current |
| forwardPowerOstA OBJECT-TYPE The measured forwarded power [W] of the OutputstageA. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.25 | FloatingPoint | read-only | current |
| reflectedPowerOstA OBJECT-TYPE The measured reflected power [W] of the OutputstageA. Not available for lowpower systems. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.26 | FloatingPoint | read-only | current |
| forwardPowerOstB OBJECT-TYPE The measured forwarded power [W] of the OutputstageB. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.27 | FloatingPoint | read-only | current |
| reflectedPowerOstB OBJECT-TYPE The measured reflected power [W] of the OutputstageB. Not available for lowpower systems. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.28 | FloatingPoint | read-only | current |
| powerSupply OBJECT-TYPE Monitoring value of the output voltages of the power supply. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.29 | FloatingPoint | read-only | current |
| additionalPowerSupply OBJECT-TYPE Shows whether the NetCCU has an additional (external) power supply. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.30 | TruthValue | read-only | current |
| internalPowerSupply OBJECT-TYPE Monitoring value of the output voltages of the internal power supply. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.31 | FloatingPoint | read-only | current |
| externalPowerSupply OBJECT-TYPE Monitoring value of the output voltages of the external power supply. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.2.32 | FloatingPoint | read-only | current |
| detailedInfo OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3 | |||
| excInputTable OBJECT-TYPE A table for more detailed information about the exciter. These values are all read-only. For settings, refer to commands. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2 | not-accessible | current | |
| excInputEntry OBJECT-TYPE An entry for a designated input channel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1 | not-accessible | current | |
| excInputExcIdx OBJECT-TYPE The index for exciterA (and exciterB if there are DualDrive systems). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.1 | IndexAB | not-accessible | current |
| excInputChannelIdx OBJECT-TYPE The index for the different input channels. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.2 | Integer32 (1..6) | not-accessible | current |
| excInputChannelName OBJECT-TYPE This is the logical name for the index for the different input channels. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.3 | INTEGER {hp1(1), hp2(2), lp1(3), lp2(4), activeHP(5), activeLP(6)} | read-only | current |
| excInputConnected OBJECT-TYPE The input channel is connected. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.4 | TruthValue | read-only | current |
| excInputSeamless OBJECT-TYPE The input channel is in seamless mode. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.5 | TruthValue | read-only | current |
| excInputPreselected OBJECT-TYPE The input channel is the preselected. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.6 | TruthValue | read-only | current |
| excInputActive OBJECT-TYPE The input channel is active. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.7 | TruthValue | read-only | current |
| excInputMipFail OBJECT-TYPE Input channel MIP fail. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.8 | TruthValue | read-only | current |
| excInputBandwidth OBJECT-TYPE The bandwidth used by the input channel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.9 | INTEGER {mhz5(1), mhz6(2), mhz7(3), mhz8(4)} | read-only | current |
| excInputFFTLength OBJECT-TYPE The used FFT length (depends on the DVB network). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.10 | INTEGER {k2(1), k8(2), k4(3)} | read-only | current |
| excInputGuardInterval OBJECT-TYPE The Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.11 | INTEGER {oneOf32(1), oneOf16(2), oneOf8(3), oneOf4(4)} | read-only | current |
| excInputConstellation OBJECT-TYPE This parameter sets the modulation mode. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.12 | INTEGER {qpsk(1), qam16(2), qam64(3)} | read-only | current |
| excInputAlpha OBJECT-TYPE An alpha greater than zero enables the hierarchical coding mode. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.13 | INTEGER {noHierarchy(1), one(2), two(3), four(4)} | read-only | obsolete |
| excInputCellID OBJECT-TYPE Via Cell ID the receiver knows the current network. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.14 | Integer32 (0..65535) | read-only | current |
| excInputInterleaver OBJECT-TYPE Enables the bit interleaver for hierarchical coding | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.15 | INTEGER {indepth(1), nat(2)} | read-only | current |
| excInputCodeRate OBJECT-TYPE Coderate can be set separately for HP and LP channel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.16 | INTEGER {oneOf2(1), twoOf3(2), threeOf4(3), fiveOf6(4), sevenOf8(5)} | read-only | current |
| excInputPacketLength OBJECT-TYPE The Packet length for the channel. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.17 | Integer32 (188..208) | read-only | current |
| excInputMeasuredDatarate OBJECT-TYPE The measured datarate of the input. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.18 | Integer32 | read-only | current |
| excInputRequiredDatarate OBJECT-TYPE The required datarate of the input. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.19 | Integer32 | read-only | current |
| excInputMaximumDelay OBJECT-TYPE Period of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inserter and serves as a basis for all the transmitters in the SFN. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.20 | Integer32 (0..100000000) | read-only | current |
| ostTable OBJECT-TYPE The table of racks. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3 | not-accessible | current | |
| ostEntry OBJECT-TYPE A row (an entry) for one rack. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1 | not-accessible | current | |
| ostIdx OBJECT-TYPE The dedicated outputstage (A/B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.1 | IndexAB | not-accessible | current |
| ostRackIdx OBJECT-TYPE The rack number (1..10). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.2 | IndexRack | not-accessible | current |
| ostRackInletTemperature OBJECT-TYPE The inlet temperature. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.3 | FloatingPoint | read-only | current |
| ostRackOutletTemperature OBJECT-TYPE The outlet temperature. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.4 | FloatingPoint | read-only | current |
| ostRackAuxPowerSupply OBJECT-TYPE Control voltage of auxiliary power supply of the designated rack. The value should be between 11.1 to 13.2 V. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.5 | FloatingPoint | read-only | current |
| ostRackAmpIdx OBJECT-TYPE Amplifier Index | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.400 | IndexAmplifier | not-accessible | current |
| ostRackAmpI1A OBJECT-TYPE The power amplifier module current (I_1A). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.401 | FloatingPoint | read-only | current |
| ostRackAmpI2A OBJECT-TYPE The power amplifier module current (I_2A). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.402 | FloatingPoint | read-only | current |
| ostRackAmpI3A OBJECT-TYPE The power amplifier module current (I_3A). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.403 | FloatingPoint | read-only | current |
| ostRackAmpI4A OBJECT-TYPE The power amplifier module current (I_4A). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.404 | FloatingPoint | read-only | current |
| ostRackAmpI1B OBJECT-TYPE The power amplifier module current (I_1B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.405 | FloatingPoint | read-only | current |
| ostRackAmpI2B OBJECT-TYPE The power amplifier module current (I_2B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.406 | FloatingPoint | read-only | current |
| ostRackAmpI3B OBJECT-TYPE The power amplifier module current (I_3B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.407 | FloatingPoint | read-only | current |
| ostRackAmpI4B OBJECT-TYPE The power amplifier module current (I_4B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.408 | FloatingPoint | read-only | current |
| ostRackAmpIDrv OBJECT-TYPE The driver module current (I_DRV). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.409 | FloatingPoint | read-only | current |
| ostRackAmpUDc OBJECT-TYPE The power amplifier supply voltage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.410 | FloatingPoint | read-only | current |
| ostRackAmpIDc OBJECT-TYPE The power amplifier supply current. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.411 | FloatingPoint | read-only | current |
| ostRackAmpUDcControl OBJECT-TYPE The power supply control voltage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.412 | FloatingPoint | read-only | current |
| ostRackAmpUReg OBJECT-TYPE The power amplifier AGC voltage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.413 | FloatingPoint | read-only | current |
| ostRackAmpPowerA OBJECT-TYPE The voltage power detector A. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.414 | FloatingPoint | read-only | current |
| ostRackAmpPowerB OBJECT-TYPE The voltage power detector B. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.415 | FloatingPoint | read-only | current |
| ostRackAmpPowerOut OBJECT-TYPE The voltage forward power detector. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.416 | FloatingPoint | read-only | current |
| ostRackAmpPowerReflection OBJECT-TYPE The voltage reflected power detector. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.417 | FloatingPoint | read-only | current |
| ostRackAmpPowerReference OBJECT-TYPE The reference voltage for output power. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.418 | FloatingPoint | read-only | current |
| ostRackAmpDeltaPhase OBJECT-TYPE The measured phase delta for output power. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.419 | FloatingPoint | read-only | current |
| ostRackAmpCmdDeltaPhase OBJECT-TYPE The phase delta setting for output power. The range is -50.0% to 50.0%. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.420 | FloatingPoint | read-write | current |
| exciterStatusTable OBJECT-TYPE Exciter status values. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20 | not-accessible | current | |
| exciterStatusEntry OBJECT-TYPE A row (an entry) for one exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1 | not-accessible | current | |
| excStatusExcIdx OBJECT-TYPE The dedicated exciter (A/B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.3 | IndexAB | not-accessible | current |
| excStatusRfOutputAgcRegulation OBJECT-TYPE Shows the operating point of the RF regulator. The shown value should be around 50 per cent. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.4 | FloatingPoint | read-only | current |
| excStatusRfIqAdjustAuto OBJECT-TYPE Automatic I/Q-Adjust. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.5 | INTEGER {notAdjusted(1), inProgress(2), adjusted(3)} | read-only | current |
| excStatusRfIqAdjustLO1Frequency OBJECT-TYPE Modulator LO1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.6 | FloatingPoint | read-only | current |
| excStatusNominalPower OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.7 | Integer32 | read-write | current |
| excStatusVSWR OBJECT-TYPE Voltage Standing Wave Ratio | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.9 | FloatingPoint | read-only | current |
| excStatusSfnDelayProcessing OBJECT-TYPE The Minimum signal transmit time through the exciter. This delay depends on the DVB transmission parameters. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.13 | FloatingPoint | read-only | current |
| excStatusSfnDelayDynamic OBJECT-TYPE The period of time by which signal processing is artificially delayed so that the desired time of transmission is obtained. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.14 | FloatingPoint | read-only | current |
| excStatusSfnDelayNetwork OBJECT-TYPE The signal propagation time between the play-out center (MIP inserter) and the exciter input. This delay depends on the transmission path used. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.15 | FloatingPoint | read-only | current |
| excStatusSfnDelayTxOffset OBJECT-TYPE An individual transmitter specific delay. It can be adjusted via data carousel of the SFN adapter. It is true for a specific transmitter address. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.16 | FloatingPoint | read-only | current |
| excStatusSfnDelayMaximum OBJECT-TYPE The period of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inserter and serves as a basis for all the transmitters in the SFN. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.17 | FloatingPoint | read-only | current |
| excStatusSfnDelayTotal OBJECT-TYPE The actual signal transit time through the exciter. This is derived from the sum of static-, dynamic-, offset- and processing delay. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.18 | FloatingPoint | read-only | current |
| excStatusAmplifierControl OBJECT-TYPE Amplifier control status | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.20 | INTEGER {on(1), off(2)} | read-only | current |
| excStatusReqDataRateHP OBJECT-TYPE Required data rate on HP input with respect to the current TPS settings. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.30 | Integer32 | read-only | current |
| excStatusReqDataRateLP OBJECT-TYPE Required data rate on LP input with respect to the current TPS settings. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.31 | Integer32 | read-only | current |
| excStatusFailDelay OBJECT-TYPE Shows whether the fail delay time is qualified. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.40 | FailDelayStatus | read-only | current |
| exciterPrecorrectionTable OBJECT-TYPE Exciter status values. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21 | not-accessible | current | |
| exciterPrecorrectionEntry OBJECT-TYPE A row (an entry) for one exciter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1 | not-accessible | current | |
| excPrecExcIdx OBJECT-TYPE The dedicated exciter (A/B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.3 | IndexAB | not-accessible | current |
| excPrecLinCorrection OBJECT-TYPE Switches on/turns off the linear precorrector. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.4 | SwitchOnOff | read-write | current |
| excPrecLinAutomaticADE OBJECT-TYPE Enables /disables the automatic precorrector. To get the ADE in work linear precorrection has to be switched on. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.5 | INTEGER {manual(1), automatic(2), adaptive(3)} | read-write | current |
| excPrecLinMaxAmplitudeRipple OBJECT-TYPE Sets te maximum ripple for automatic amplitude correction (0.0 ... 2.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.6 | FloatingPoint | read-write | current |
| excPrecLinMaxGroupDelayRipple OBJECT-TYPE Sets the maximum ripple for automatic group delay correction. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.7 | Integer32 (0..500) | read-write | current |
| excPrecLinAmplitudeRipple OBJECT-TYPE Shows the current amplitude ripple. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.8 | FloatingPoint | read-only | current |
| excPrecLinGroupDelayRipple OBJECT-TYPE Shows the current group delay ripple. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.9 | Integer32 | read-only | current |
| excPrecLinInputLevel OBJECT-TYPE Shows the state of the feedback signal from the measurement point between output stage and antenna. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.10 | INTEGER {tooHigh(1), ok(2), tooLow(3), failure(4)} | read-only | current |
| excPrecLinAutomatic OBJECT-TYPE Shows if the automatic precorrector works properly. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.11 | INTEGER {disabled(1), active(2), calculate(3), measure(4)} | read-only | current |
| excPrecNonlinCorrection OBJECT-TYPE Switches on/turns off the nonlinear precorrector. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.12 | SwitchOnOff | read-write | current |
| excPrecNonlinAutomaticADE OBJECT-TYPE Enables /disables the automatic precorrector. To get the ADE in work nonlinear precorrection has to be switched on. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.13 | INTEGER {manual(1), automatic(2), adaptive(3)} | read-write | current |
| excPrecNonlinThresholdShoulders OBJECT-TYPE The target shoulder distance for ADE (0.0 ... 40.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.14 | FloatingPoint | read-write | current |
| excPrecNonlinShoulderLeft OBJECT-TYPE Displays the current measurement for the left handed shoulder distance. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.15 | FloatingPoint | read-only | current |
| excPrecNonlinShoulderRight OBJECT-TYPE Displays the current measurement of the right handed shoulder. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.16 | FloatingPoint | read-only | current |
| excPrecNonlinInputLevel OBJECT-TYPE Shows the state of the feedback signal from the measurement point between output stage and antenna. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.17 | INTEGER {tooHigh(1), ok(2), tooLow(3), failure(4)} | read-only | current |
| excPrecNonlinAutomatic OBJECT-TYPE Shows if the automatic precorrector works properly. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.18 | INTEGER {disabled(1), active(2), calculate(3), measure(4)} | read-only | current |
| excPrecUserState OBJECT-TYPE status of the user precorrection settings | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.100 | EqualizerCalibrationState | read-only | current |
| excPrecFactoryState OBJECT-TYPE status of the factory precorrection settings | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.101 | EqualizerCalibrationState | read-only | current |
| excPrecRestoreCurrentSettings OBJECT-TYPE restores current factory precorrection setting | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.102 | INTEGER {stop(1), start(2)} | read-write | current |
| excPrecRestoreAllSettings OBJECT-TYPE restores all factory precorrection settings | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.103 | INTEGER {stop(1), start(2)} | read-write | current |
| configurationTable OBJECT-TYPE Table for Type Configuration parameters. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30 | not-accessible | current | |
| configurationEntry OBJECT-TYPE An entry for the Type Configuration parameters. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1 | not-accessible | current | |
| configTvStandardIdx OBJECT-TYPE The index for the TV standard. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.3 | TvStandard | not-accessible | current |
| configTvStandardName OBJECT-TYPE The name of the TV standard as a text. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.5 | TvStandard | read-only | current |
| configRxFrequency OBJECT-TYPE The input frequency for input 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.6 | Integer32 (160000000..910000000) | read-write | current |
| configFrequency OBJECT-TYPE The output frequency for input 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.7 | Integer32 (47000000..1500000000) | read-write | current |
| configPower OBJECT-TYPE The output power (0.0 ... 2500.0) for input 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.8 | FloatingPoint | read-write | current |
| configInputSource OBJECT-TYPE The source for input 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.9 | InputSource | read-write | current |
| timeSchedulerTable OBJECT-TYPE Table for Time Scheduler parameters. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31 | not-accessible | current | |
| timeSchedulerEntry OBJECT-TYPE An entry in the table for the Time Scheduler parameters. A row in this table is created by setting the value of schedulerRowStatus to 'createAndGo' or 'createAndWait'. A row in this table is deleted by setting the value of schedulerRowStatus to 'destroy'. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1 | not-accessible | current | |
| schedulerDateTimeIdx OBJECT-TYPE The DateAndTime index. Note: Deci-seconds different from 0 and UTC values are ignored. The index is implemented as a Fixed length string of 8 components. The last component (Deci-seconds) is always 0. Example: The DateTime of 2008-9-15,17:45:30.0 has the index: 7.216.9.15.17.45.30.0 | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.3 | DateAndTime | not-accessible | current |
| schedulerRowStatus OBJECT-TYPE This object is used to create and delete rows in the timeSchedulerTable. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.5 | RowStatus | read-create | current |
| schedulerEvent OBJECT-TYPE The event type. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.6 | INTEGER {daily(1), once(2)} | read-create | current |
| schedulerDateTime OBJECT-TYPE The start date and the time of a daily or one-time event. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.7 | DateAndTime | read-only | current |
| schedulerTvStandard OBJECT-TYPE The TV standard. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.8 | TvStandard | read-create | current |
| configuration2Table OBJECT-TYPE Table for Type Configuration parameters of input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32 | not-accessible | current | |
| configuration2Entry OBJECT-TYPE An entry for the Type Configuration parameters of input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1 | not-accessible | current | |
| config2TvStandardName OBJECT-TYPE The name of the TV standard as a text. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.5 | TvStandard | read-only | current |
| config2RxFrequency OBJECT-TYPE The input frequency for input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.6 | Integer32 (160000000..910000000) | read-write | current |
| config2Frequency OBJECT-TYPE The output frequency for input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.7 | Integer32 (47000000..1500000000) | read-write | current |
| config2Power OBJECT-TYPE The output power (0.0 ... 2500.0) for input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.8 | FloatingPoint | read-write | current |
| config2InputSource OBJECT-TYPE The source for input 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.9 | InputSource | read-write | current |
| productInfoTable OBJECT-TYPE The table for product typeplates. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100 | not-accessible | current | |
| productInfoEntry OBJECT-TYPE A row (an entry) for one typeplate. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1 | not-accessible | current | |
| prodInfoModuleIdx OBJECT-TYPE The module index. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.1 | ProdInfoModuleNameTv | not-accessible | current |
| prodInfoDeviceIdx OBJECT-TYPE The dedicated device (A/B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.2 | IndexAB | not-accessible | current |
| prodInfoRackIdx OBJECT-TYPE The rack number (1..10). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.3 | IndexRack | not-accessible | current |
| prodInfoAmpIdx OBJECT-TYPE Amplifier Index | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.4 | IndexAmplifier | not-accessible | current |
| prodInfoModuleName OBJECT-TYPE The name of the module as a text. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.5 | ProdInfoModuleNameTv | read-only | current |
| prodInfoSerialNumber OBJECT-TYPE The serial number of the subdevice. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.6 | ReadableString | read-only | current |
| prodInfoIdentNumberSW OBJECT-TYPE The Rohde&Schwarz identification number of the software, for example 2094.2090.02. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.7 | ReadableString | read-only | current |
| prodInfoVersionNumberSW OBJECT-TYPE The Rohde&Schwarz revision number of the software, for example 1.2.1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.8 | ReadableString | read-only | current |
| prodInfoIdentNumberHW OBJECT-TYPE The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.9 | ReadableString | read-only | current |
| prodInfoVersionNumberHW OBJECT-TYPE The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.10 | ReadableString | read-only | current |
| productInfoProductDateHW OBJECT-TYPE The Rohde&Schwarz production date of the hardware, | 1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.11 | DateAndTime | read-only | current |
| logbook OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4 | |||
| netCCUNumberOfEntries OBJECT-TYPE The number of entries in logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.1 | LogbookMaxEntryNumber | read-only | current |
| netCCULogbookClear OBJECT-TYPE Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.2 | Trigger | read-write | current |
| netCCULogbookTable OBJECT-TYPE NetCCU logbook table. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3 | not-accessible | current | |
| netCCULogbookEntry OBJECT-TYPE This is a entry in the logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1 | not-accessible | current | |
| netCCULogbookEntryIdx OBJECT-TYPE This is an increasing number from 1 to maximum. It is used as an index column for SNMP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.1 | LogbookMaxEntryNumber | not-accessible | current |
| netCCULogbookEntryNbr OBJECT-TYPE This is the number of the logbook entry. It is an decreasing number from maximum down to 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.2 | LogbookMaxEntryNumber | read-only | current |
| netCCULogbookType OBJECT-TYPE Can either be Fault, Warning or State. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.3 | EventClass | read-only | current |
| netCCULogbookSlope OBJECT-TYPE Either set (event raises) or reset (event disappears) | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.4 | LogbookEntrySlope | read-only | current |
| netCCULogbookMessage OBJECT-TYPE See RS-XX8000-COMMON-MIB - TextualConvention - LogbookEntryMessagesNetCCU for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.5 | LogbookEntryMessagesNetCCU | read-only | current |
| netCCULogbookDateTime OBJECT-TYPE netCCULogbookDateTime | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.6 | DateAndTime | read-only | current |
| exciterANumberOfEntries OBJECT-TYPE The number of entries in logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.4 | LogbookMaxEntryNumber | read-only | current |
| exciterALogbookClear OBJECT-TYPE Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.5 | Trigger | read-write | current |
| exciterALogbookTable OBJECT-TYPE ExciterA logbook table. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6 | not-accessible | current | |
| exciterALogbookEntry OBJECT-TYPE This is a entry in the logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1 | not-accessible | current | |
| excALogbookEntryIdx OBJECT-TYPE This is an increasing number from 1 to maximum. It is used as an index column for SNMP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.1 | LogbookMaxEntryNumber | not-accessible | current |
| excALogbookEntryNbr OBJECT-TYPE This is the number of the logbook entry. It is an decreasing number from maximum down to 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.2 | LogbookMaxEntryNumber | read-only | current |
| excALogbookType OBJECT-TYPE Can either be Fault, Warning or State. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.3 | EventClass | read-only | current |
| excALogbookSlope OBJECT-TYPE Either set (event raises) or reset (event disappears) | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.4 | LogbookEntrySlope | read-only | current |
| excALogbookMessage OBJECT-TYPE See RS-XX8000-COMMON-MIB - TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.5 | LogbookEntryMessagesExcTv | read-only | current |
| excALogbookDateTime OBJECT-TYPE The time of the logbook entry. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.6 | DateAndTime | read-only | current |
| outputstageANumberOfEntries OBJECT-TYPE The number of entries in logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.7 | LogbookMaxEntryNumber | read-only | current |
| outputstageALogbookClear OBJECT-TYPE Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.8 | Trigger | read-write | current |
| outputstageALogbookTable OBJECT-TYPE OutputstageA logbook table. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9 | not-accessible | current | |
| outputstageALogbookEntry OBJECT-TYPE This is a entry in the logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1 | not-accessible | current | |
| ostALogbookEntryIdx OBJECT-TYPE This is an increasing number from 1 to maximum. It is used as an index column for SNMP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.1 | LogbookMaxEntryNumber | not-accessible | current |
| ostALogbookEntryNbr OBJECT-TYPE This is the number of the logbook entry. It is an decreasing number from maximum down to 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.2 | LogbookMaxEntryNumber | read-only | current |
| ostALogbookType OBJECT-TYPE Can either be Fault, Warning or State. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.3 | EventClass | read-only | current |
| ostALogbookSlope OBJECT-TYPE Either set (event raises) or reset (event disappears) | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.4 | LogbookEntrySlope | read-only | current |
| ostALogbookMessage OBJECT-TYPE See RS-XX8000-COMMON-MIB - TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.5 | LogbookEntryMessagesOST | read-only | current |
| ostALogbookDateTime OBJECT-TYPE The time of the logbook entry. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.6 | DateAndTime | read-only | current |
| exciterBNumberOfEntries OBJECT-TYPE The number of entries in logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.10 | LogbookMaxEntryNumber | read-only | current |
| exciterBLogbookClear OBJECT-TYPE Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.11 | Trigger | read-write | current |
| exciterBLogbookTable OBJECT-TYPE ExciterB logbook table. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12 | not-accessible | current | |
| exciterBLogbookEntry OBJECT-TYPE This is a entry in the logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1 | not-accessible | current | |
| excBLogbookEntryIdx OBJECT-TYPE This is an increasing number from 1 to maximum. It is used as an index column for SNMP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.1 | LogbookMaxEntryNumber | not-accessible | current |
| excBLogbookEntryNbr OBJECT-TYPE This is the number of the logbook entry. It is an decreasing number from maximum down to 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.2 | LogbookMaxEntryNumber | read-only | current |
| excBLogbookType OBJECT-TYPE Can either be Fault, Warning or State. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.3 | EventClass | read-only | current |
| excBLogbookSlope OBJECT-TYPE Either set (event raises) or reset (event disappears) | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.4 | LogbookEntrySlope | read-only | current |
| excBLogbookMessage OBJECT-TYPE See RS-XX8000-COMMON-MIB - TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.5 | LogbookEntryMessagesExcTv | read-only | current |
| excBLogbookDateTime OBJECT-TYPE The time of the logbook entry. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.6 | DateAndTime | read-only | current |
| outputstageBNumberOfEntries OBJECT-TYPE The number of entries in logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.13 | LogbookMaxEntryNumber | read-only | current |
| outputstageBLogbookClear OBJECT-TYPE Clear the logbook. idle(1) --> ready clear(2) --> do clear now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.14 | Trigger | read-write | current |
| outputstageBLogbookTable OBJECT-TYPE OutputstageB logbook table. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15 | not-accessible | current | |
| outputstageBLogbookEntry OBJECT-TYPE This is a entry in the logbook. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1 | not-accessible | current | |
| ostBLogbookEntryIdx OBJECT-TYPE This is an increasing number from 1 to 128. It is used as an index column for SNMP. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.1 | LogbookMaxEntryNumber | not-accessible | current |
| ostBLogbookEntryNbr OBJECT-TYPE This is the number of the logbook entry. It is an decreasing number from max 128 down to 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.2 | LogbookMaxEntryNumber | read-only | current |
| ostBLogbookType OBJECT-TYPE Can either be Fault, Warning or State. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.3 | EventClass | read-only | current |
| ostBLogbookSlope OBJECT-TYPE Either set (event raises) or reset (event disappears) | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.4 | LogbookEntrySlope | read-only | current |
| ostBLogbookMessage OBJECT-TYPE See RS-XX8000-COMMON-MIB - TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.5 | LogbookEntryMessagesOST | read-only | current |
| ostBLogbookDateTime OBJECT-TYPE The time of the logbook entry. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.6 | DateAndTime | read-only | current |
| rfProbesTable OBJECT-TYPE This table contains all commands for the RF probes. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5 | not-accessible | current | |
| rfProbesEntry OBJECT-TYPE An entry for a designated transmitter and device. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1 | not-accessible | current | |
| rfProbesNetCCURfProbe1 OBJECT-TYPE Current voltage on RF Probe 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.1 | FloatingPoint | read-only | current |
| rfProbesNetCCURfProbe2 OBJECT-TYPE Current voltage on RF Probe 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.2 | FloatingPoint | read-only | current |
| rfProbesAntFwdNominal OBJECT-TYPE This sets the nominal value [W] of the transmitter (to antenna). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.3 | FloatingPoint | read-write | current |
| rfProbesAntFwdWarningLimit OBJECT-TYPE This sets the warning limit for the transmitters RF control (to antenna). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.4 | FloatingPoint | read-write | current |
| rfProbesAntFwdFailLimit OBJECT-TYPE This sets the fault limit for the transmitters RF control (to antenna). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.5 | FloatingPoint | read-write | current |
| rfProbesAntFwdDelayTimeRfFail OBJECT-TYPE This sets the delay time for the RF Fail control (to antenna). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.6 | Integer32 (1..20) | read-write | current |
| rfProbesAntFwdSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.7 | Trigger | read-write | current |
| rfProbesAntFwdSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.8 | Trigger | read-write | current |
| rfProbesAntReflWarningLimit OBJECT-TYPE This sets the warning limit for the transmitters reflection control (to antenna). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.9 | FloatingPoint | read-write | current |
| rfProbesAntReflSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.10 | Trigger | read-write | current |
| rfProbesAntReflSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.11 | Trigger | read-write | current |
| rfProbesDLFwdNominal OBJECT-TYPE This sets the nominal value [W] of the transmitter (to dummyload). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.12 | FloatingPoint | read-write | current |
| rfProbesDLFwdWarningLimit OBJECT-TYPE This sets the warning limit for the transmitters RF control (to dummyload). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.13 | FloatingPoint | read-write | current |
| rfProbesDLFwdFailLimit OBJECT-TYPE This sets the fault limit for the transmitters RF control (to dummyload). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.14 | FloatingPoint | read-write | current |
| rfProbesDLFwdDelayTimeRfFail OBJECT-TYPE This sets the delay time for the RF Fail control (to dummyload). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.15 | Integer32 (1..20) | read-write | current |
| rfProbesDLFwdSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.16 | Trigger | read-write | current |
| rfProbesDLFwdSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.17 | Trigger | read-write | current |
| rfProbesDLReflWarningLimit OBJECT-TYPE This sets the warning limit for the transmitters reflection control (to dummyload). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.18 | FloatingPoint | read-write | current |
| rfProbesDLReflSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.19 | Trigger | read-write | current |
| rfProbesDLReflSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.20 | Trigger | read-write | current |
| rfProbesOstIdx OBJECT-TYPE The dedicated outputstage (A/B). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.21 | IndexAB | not-accessible | current |
| rfProbesOstFwdNominal OBJECT-TYPE This sets the nominal value [W] of the outputstage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.22 | FloatingPoint | read-write | current |
| rfProbesOstFwdWarningLimit OBJECT-TYPE This sets the warning limit for the outputstage RF control. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.23 | FloatingPoint | read-write | current |
| rfProbesOstFwdFailLimit OBJECT-TYPE This sets the fault limit for the outputstage RF control. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.24 | FloatingPoint | read-write | current |
| rfProbesOstFwdDelayTimeRfFail OBJECT-TYPE This sets the delay time for the outputstage RF Fail control. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.25 | Integer32 (1..20) | read-write | current |
| rfProbesOstFwdSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.26 | Trigger | read-write | current |
| rfProbesOstFwdSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.27 | Trigger | read-write | current |
| rfProbesOstReflWarningLimit OBJECT-TYPE This sets the warning limit for the outputstage reflection control. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.28 | FloatingPoint | read-write | current |
| rfProbesOstReflSetOffset OBJECT-TYPE This triggers Set Offset. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.29 | Trigger | read-write | current |
| rfProbesOstReflSetGain OBJECT-TYPE This triggers Set Gain. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.30 | Trigger | read-write | current |
| rackTable OBJECT-TYPE This table contains important commands for the racks. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6 | not-accessible | current | |
| rackEntry OBJECT-TYPE An entry for a designated rack or rack's rf probe. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1 | not-accessible | current | |
| ostDeviceIdx OBJECT-TYPE The index to address outputstageA and outputstageB. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.2 | IndexAB | not-accessible | current |
| rackIdx OBJECT-TYPE The index to address the racks. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.3 | IndexRack | not-accessible | current |
| rackRfProbeIdx OBJECT-TYPE The index to address forward and reflected RF probes. For not RF probe parameters this index is always 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.4 | INTEGER {forward(1), reflected(2)} | not-accessible | current |
| amplifiersPerRack OBJECT-TYPE The number of amplifiers of a rack. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.6 | Integer32 (1..10) | read-only | current |
| rackRfEventSignalling OBJECT-TYPE This configures whether to signal rf events or not. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.7 | TruthValue | read-write | current |
| rackReferenceVoltage OBJECT-TYPE This parameter controls the reference voltage (31.0 ... 100.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.8 | FloatingPoint | read-write | current |
| amplifiersPowerSupply OBJECT-TYPE This parameter controls the power supplies of the amplifier within the rack (31.0 ... 100.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.9 | FloatingPoint | read-write | current |
| rackGeneralPurposeInput OBJECT-TYPE Setting of the general purpose input behaviour. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.10 | INTEGER {unused(1), doorOpen(2), extCoolingWarning(3), extCoolingFault(4)} | read-write | current |
| rackOnOff OBJECT-TYPE This switches the rack on/off. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.20 | SwitchOnOff | read-write | current |
| rfProbePresent OBJECT-TYPE If the RF probe of this rack is present. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.50 | TruthValue | read-only | current |
| rfProbeConfigurationLabel OBJECT-TYPE Name for the measured signal on RF Probe. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.51 | ReadableString (SIZE(0..12)) | read-write | obsolete |
| rfProbeConfigurationNominalValue OBJECT-TYPE The nominal value of the measured signal. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.52 | Integer32 (0..100000) | read-write | current |
| rfProbeThresholdRfFailLimit OBJECT-TYPE Fault limit for the RF control (-20.0 ... 0.0). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.55 | FloatingPoint | read-write | current |
| rfProbeThresholdTimeoutRfFailCtr OBJECT-TYPE Timeout for RF Fail Control. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.56 | Integer32 (1..20) | read-write | current |
| rfProbeThresholdWarningLimit OBJECT-TYPE Warning limit for the RF control (-20.0 ... 0.0). For reflected probes: Warning limit for the reflection control. This limit is added to the fault limit to generate the real warning limit; e.g. the fault limit is -17.0dB and the warning limit is -3.0dB, so the warning is active on a reflected power higher than -20.0 dB. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.57 | FloatingPoint | read-write | current |
| rfProbeCalibrationGain OBJECT-TYPE Measured value of gain calibration. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.60 | FloatingPoint | read-only | current |
| rfProbeCalibrationOffset OBJECT-TYPE Measured value of offset calibration. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.61 | FloatingPoint | read-only | current |
| rfProbeCalibrationSetGain OBJECT-TYPE Sets the gain calibration. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.62 | Trigger | read-write | current |
| rfProbeCalibrationSetOffset OBJECT-TYPE Sets the offset calibration. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.63 | Trigger | read-write | current |
| rfProbeMeasuredValue OBJECT-TYPE Measured forward/reflected power of antenna signal. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.65 | FloatingPoint | read-only | current |
| sx801AmplifierTable OBJECT-TYPE Amplifier status values for SX801 amplifiers. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7 | not-accessible | current | |
| sx801AmplifierEntry OBJECT-TYPE A row (an entry) for one amplifier. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1 | not-accessible | current | |
| sx801AmpIdx OBJECT-TYPE The amplifier index. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.1 | IndexAmplifier | not-accessible | current |
| sx801AmpRfOut OBJECT-TYPE Shows if the amplifier generates an RF or not. off(1): The amplifier output is switched off e.g. because the amplifier gets no input signal or the transmitter has been switched off warning(2): There is an RF but its level is less than the RF warning limit. ok(3): The RF level is greater than the RF warning limit. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.2 | Sx801AmplifierState | read-only | current |
| sx801AmpRfIn OBJECT-TYPE Displays the state of the amplifier input. off(1): no input signal detected warning(2): the level of the input signal is too low or too high. ok(3): input signal is OK. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.3 | Sx801AmplifierState | read-only | current |
| sx801AmpReflection OBJECT-TYPE A reflection on RF output of this Amplifier module has been detected. This leads to a reduction of output power of the amplifier. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.4 | INTEGER {off(1), warning(2), unknown(3), fault(4)} | read-only | current |
| sx801AmpOn OBJECT-TYPE Shows if the amplifier has been switched on by the control unit. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.5 | INTEGER {off(1), on(3), unknown(4)} | read-only | current |
| sx801AmpAC OBJECT-TYPE Shows the state of primary voltage of the power supply. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.6 | Sx801AmplifierState | read-only | current |
| sx801AmpCommunication OBJECT-TYPE Displays if the CAN communication between amplifier and Sx801 is working or not. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.7 | INTEGER {off(1), unknown(2), ok(3), fault(4)} | read-only | current |
| sx801AmpTransistor OBJECT-TYPE A transistor fail is displayed here. For further information please see the amplifiers service menue. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.8 | Sx801AmplifierState | read-only | current |
| sx801AmpDriver OBJECT-TYPE Shows a failure if one of the internal driver transistors does not work properly. For further information please see the amplifiers service menue. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.9 | Sx801AmplifierState | read-only | current |
| sx801AmpTemperature OBJECT-TYPE Shows a fault if the temperature of amplifier module is too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.10 | Sx801AmplifierState | read-only | current |
| sx801AmpBlower OBJECT-TYPE Displays the state of the internal blowers. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.11 | Sx801AmplifierState | read-only | current |
| sx801AmpRegulation OBJECT-TYPE Shows a fault if the amplifier is not able to control its output power. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.12 | Sx801AmplifierState | read-only | current |
| sx801AmpUpdate OBJECT-TYPE Firmware update is in progress. This will be started automatically during a software update procedure of the transmitter. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.13 | TruthValue | read-only | current |
| sx801Supply1Temperature OBJECT-TYPE Shows a fault if the temperature of power supply one is too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.14 | Sx801AmplifierState | read-only | current |
| sx801Supply2Temperature OBJECT-TYPE Shows a fault if the temperature of power supply two is too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.15 | Sx801AmplifierState | read-only | current |
| sx801SupplyRTemperature OBJECT-TYPE Shows a fault if the temperature of the reserve power supply is too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.16 | Sx801AmplifierState | read-only | current |
| sx801Supply1DC OBJECT-TYPE Shows a fault if the output voltage of power supply one is not ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.17 | Sx801AmplifierState | read-only | current |
| sx801Supply2DC OBJECT-TYPE Shows a fault if the output voltage of power supply two is not ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.18 | Sx801AmplifierState | read-only | current |
| sx801SupplyRDC OBJECT-TYPE Shows a fault if the output voltage of the reserve power supply is not ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.19 | Sx801AmplifierState | read-only | current |
| sx801AmpValueI1 OBJECT-TYPE The internal current from transistor pair 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.50 | FloatingPoint | read-only | current |
| sx801AmpValueI2 OBJECT-TYPE The internal current from transistor pair 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.51 | FloatingPoint | read-only | current |
| sx801AmpValueI3 OBJECT-TYPE The internal current from transistor pair 3. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.52 | FloatingPoint | read-only | current |
| sx801AmpValueI4 OBJECT-TYPE The internal current from transistor pair 4. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.53 | FloatingPoint | read-only | current |
| sx801AmpValueIPre OBJECT-TYPE The internal current from preamplifier. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.54 | FloatingPoint | read-only | current |
| sx801AmpValueIDrv1 OBJECT-TYPE The internal current from driver transistor pair 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.55 | FloatingPoint | read-only | current |
| sx801AmpValueIDrv2 OBJECT-TYPE The internal current from driver transistor pair 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.56 | FloatingPoint | read-only | current |
| sx801AmpValuePowerOut OBJECT-TYPE The base value in Volt to calculate the output power of this amplifier module. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.57 | FloatingPoint | read-only | current |
| sx801AmpValueReflection OBJECT-TYPE The base value in Volt for detection of reflections. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.58 | FloatingPoint | read-only | current |
| sx801AmpValueVRef OBJECT-TYPE The internal reference voltage to set the output power. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.59 | FloatingPoint | read-only | current |
| sx801AmpValueVReg OBJECT-TYPE The internal value for output power regulation. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.60 | FloatingPoint | read-only | current |
| sx801AmpValueTemperature OBJECT-TYPE The internal temperature of Amplifier. In case of L-band amplifier, the shown temperature is valid only, if the amplifier is switched on. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.61 | FloatingPoint | read-only | current |
| sx801AmpValueMonAtt OBJECT-TYPE The attenuation of monitoring output on the front of the amplifier module (Amp RF Mon). | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.62 | FloatingPoint | read-only | current |
| sx801AmpValueVAux1 OBJECT-TYPE The voltage power detector 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.63 | FloatingPoint | read-only | current |
| sx801AmpValueVAux2 OBJECT-TYPE The voltage power detector 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.64 | FloatingPoint | read-only | current |
| sx801Supply1ValuePwr OBJECT-TYPE The power supply one control voltage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.65 | FloatingPoint | read-only | current |
| sx801Supply2ValuePwr OBJECT-TYPE The power supply two control voltage. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.66 | FloatingPoint | read-only | current |
| sx801Supply1ValueDc OBJECT-TYPE The internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply one. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.67 | FloatingPoint | read-only | current |
| sx801Supply2ValueDc OBJECT-TYPE The internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply two. | 1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.68 | FloatingPoint | read-only | current |
| rsXx8000DvbTxEvents OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.3 | |||
| eventTx OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2 | |||
| eventsTxV2 OBJECT-IDENTITY Compatibility to SMIv1. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0 | current | ||
| eventsTxTable OBJECT-TYPE This table contains necessary information for handling alarms. For each alarm you have the following information: - name (get), - mask to enable/disable sending out (set/get), - priority (set/get) and - the current state (get only). | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1 | not-accessible | current | |
| eventsTxEntry OBJECT-TYPE An event entry always consists of its indexes (used for addressing within redundancy systems) and 3 values: - name: an enumerated list of all possible notifications - mask: the corresponding mask (enable/disable) - priority: the corresponding priority (value in range 0..255) - event: the event itself (active/inactive) | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1 | not-accessible | current | |
| eventTxABIdx OBJECT-TYPE The value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) for alarms. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.1 | INTEGER {a(1), b(2)} | not-accessible | current |
| eventTxRackIdx OBJECT-TYPE The number of the designated rack. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.2 | Integer32 (1..10) | not-accessible | current |
| eventTxAmpIdx OBJECT-TYPE The number of the designated amplifier. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.3 | Integer32 (1..10) | not-accessible | current |
| eventTxNameIdx OBJECT-TYPE The event number as integer. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.4 | EventMaxEntryNumber | not-accessible | current |
| eventTxName OBJECT-TYPE The event number as integer and the value as readable text. The enumeration correlates with the notifications under eventsTxV2. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.5 | INTEGER {txSummaryFault(1), txSummaryWarning(2), txLocal(3), txRfOn(4), txRfOk(5), txParamSetSubDeviceDiffers(6), txParamSetValuesChanged(7), txRfLoopProgram(8), txRfLoopReserve(9), txRfWarning(10), txReflectionWarning(11), txNetCCUFanFault(12), txNetCCUPowerSupply(13), txRfFail(14), txReflectionFault(15), txNetCCUBoardTemperatureFault(16), txNetCCUNoConnectionToExcA(17), txNetCCUNoConnectionToOstA(18), txNetCCUNoConnectionToExcB(19), txNetCCUNoConnectionToOstB(20), txAutomaticExcReady(21), txAutomaticExcChanged(22), txAutomaticExcFault(23), txAutomaticOstReady(24), txAutomaticOstChanged(25), txAutomaticOstFault(26), txNetCCUBoardTemperatureWarning(27), txInternalPowerSupplyWarning(30), txExternalPowerSupplyWarning(31), txModeSwitchOverStarted(35), txModeSwitchOverEnded(36), txModeInconsistent(37), txModeSwitchOverFailed(38), txExcSummaryFault(100), txExcSummaryWarning(101), txExcLocal(102), txExcRfOk(104), txExcInputNoConnectHP1(105), txExcInputNoConnectLP1(106), txExcInputNoConnectHP2(107), txExcInputNoConnectLP2(108), txExcInputActiveHP1(109), txExcInputActiveLP1(110), txExcInputActiveHP2(111), txExcInputActiveLP2(112), txExcOn(113), txExcRfOn(114), txExcNoInput(115), txExcRfLoop(116), txExcRfFail(117), txExcSelfTest(118), txExcOutputOpen(119), txExcBoardTemperatureWarning(120), txExcFanWarning(121), txExcFanFault(122), txExcFifoWarning(123), txExcTestSignal(124), txExcSFNDelay(125), txExcWrongDatarate(126), txExcMute(127), txExcPPSFail(128), txExcReferenceFail(129), txExcMIPFail(130), txExcInputAutomaticSwitchReady(131), txExcInputAutomaticChangedOver(132), txExcInputReseveMissing(133), txOstSummaryFault(200), txOstSummaryWarning(201), txOstRfOn(202), txOstRfOk(203), txOstNoInput(204), txOstRfWarning(205), txOstReflectionWarning(206), txOstRackWarning(207), txOstCoolingWarning(208), txOstRfFail(209), txOstReflectionFault(210), txOstACFault(211), txOstCoolingFault(212), txOstCommFault(213), txRackSumFault(300), txRackSumWarning(301), txRackOn(302), txRackGpiWarning(303), txRackFan1Fault(304), txRackFan2Fault(305), txRackCoolingSumWarning(306), txRackAmplifierSumFault(307), txRackNoLink(308), txRackGpiFault(309), txRackTemperatureFault(310), txRackACFault(311), txRackCoolingSumFault(312), txRackTempFaultAbs1(313), txRackTempFaultAbs2(314), txRackDCFault(315), txRackRfOn(318), txRackRfOk(319), txRackRfWarning(320), txRackRfFault(321), txRackReflectionWarning(322), txRackReflectionFault(323), txRackProbeNotCalibrated(330), txRackTemperatureWarning(331), txRackOvervoltProtectWarning(335), txAmpSumFault(400), txAmpSumWarning(401), txAmpPowerOn(402), txAmpDCOk(403), txAmpACOk(404), txAmpRfInFail(405), txAmpRfFail(406), txAmpReflectionFault(407), txAmpTemperatureFault(408), txAmpTransistorFault(409)} | read-only | current |
| eventTxMask OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.6 | EventMask | read-write | current |
| eventTxPriority OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.7 | EventPriority | read-write | current |
| eventTxEvent OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.8 | EventState | read-only | current |
| rsXx8000DvbTxConf OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.5 | |||
| rsXx8000DvbTxGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1 | |||
| rsXx8000DvbTxCompl OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3 |
Notifications
| Name | OID | Status |
|---|---|---|
| txSummaryFault NOTIFICATION-TYPE Transmitter Summary Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.1 | current |
| txSummaryWarning NOTIFICATION-TYPE Transmitter Summary Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.2 | current |
| txLocal NOTIFICATION-TYPE Transmitter Local/Remote | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.3 | current |
| txRfOn NOTIFICATION-TYPE Transmitter RF On/Off | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.4 | current |
| txRfOk NOTIFICATION-TYPE Transmitter RF Ok / Not OK | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.5 | current |
| txParamSetSubDeviceDiffers NOTIFICATION-TYPE Parameterset of subdevice is different. The currently loaded parameterset is inconsistent because a subdevice (e.g. an exciter) has a different configuration than expected. To correct this, save settings to the current or save a complete new. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.6 | obsolete |
| txParamSetValuesChanged NOTIFICATION-TYPE Value Of Current Parameterset Changed. The currently loaded parameterset is inconsistent because there were changes happening since the load/save of it. To correct this, save settings to the current or save a complete new. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.7 | current |
| txRfLoopProgram NOTIFICATION-TYPE NetCCU Loop Program | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.8 | current |
| txRfLoopReserve NOTIFICATION-TYPE NetCCU Loop Reserve | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.9 | current |
| txRfWarning NOTIFICATION-TYPE NetCCU RF Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.10 | current |
| txReflectionWarning NOTIFICATION-TYPE NetCCU Reflection Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.11 | current |
| txNetCCUFanFault NOTIFICATION-TYPE NetCCU Fan Fault. This is valid, if Fan Control is switched on (see menu NetCCU Setup - Common). | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.12 | current |
| txNetCCUPowerSupply NOTIFICATION-TYPE NetCCU Power Supply | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.13 | current |
| txRfFail NOTIFICATION-TYPE NetCCU RF Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.14 | current |
| txReflectionFault NOTIFICATION-TYPE NetCCU Reflection Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.15 | current |
| txNetCCUBoardTemperatureFault NOTIFICATION-TYPE NetCCU Board Temperature Fault deprecated: this information is now handled as a warning (txNetCCUBoardTemperatureWarning) | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.16 | deprecated |
| txNetCCUNoConnectionToExcA NOTIFICATION-TYPE NetCCU Connection To ExciterA Faulty | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.17 | current |
| txNetCCUNoConnectionToOstA NOTIFICATION-TYPE NetCCU Connection To OutputstageA Faulty | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.18 | current |
| txNetCCUNoConnectionToExcB NOTIFICATION-TYPE NetCCU Connection To ExciterB Faulty | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.19 | current |
| txNetCCUNoConnectionToOstB NOTIFICATION-TYPE NetCCU Connection To OutputstageB Faulty | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.20 | current |
| txAutomaticExcReady NOTIFICATION-TYPE Exciter Automatic Ready. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.21 | current |
| txAutomaticExcChanged NOTIFICATION-TYPE Exciter Automatic Changed. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.22 | current |
| txAutomaticExcFault NOTIFICATION-TYPE Exciter Automatic Fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.23 | current |
| txAutomaticOstReady NOTIFICATION-TYPE Outputstage Automatic Ready. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.24 | current |
| txAutomaticOstChanged NOTIFICATION-TYPE Outputstage Automatic Changed. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.25 | current |
| txAutomaticOstFault NOTIFICATION-TYPE Outputstage Automatic Fault. This paramter is only available for systems with an automatic output switch. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.26 | current |
| txNetCCUBoardTemperatureWarning NOTIFICATION-TYPE NetCCU Board Temperature Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.27 | current |
| txInternalPowerSupplyWarning NOTIFICATION-TYPE NetCCU internal Power Supply warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.30 | current |
| txExternalPowerSupplyWarning NOTIFICATION-TYPE NetCCU external (additional) Power Supply warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.31 | current |
| txModeSwitchOverStarted NOTIFICATION-TYPE Switch over of TX mode started. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.35 | current |
| txModeSwitchOverEnded NOTIFICATION-TYPE Switch over of TX mode ended. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.36 | current |
| txModeInconsistent NOTIFICATION-TYPE An inconsistency in configuration of TX mode was detected. The CCU and exiter configurations are incompatible. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.37 | current |
| txModeSwitchOverFailed NOTIFICATION-TYPE Switch over of TX mode failed. Please check whether the configurations of CCU and exciter are correct. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.38 | current |
| txExcSummaryFault NOTIFICATION-TYPE Exciter Summary Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.100 | current |
| txExcSummaryWarning NOTIFICATION-TYPE Exciter Summary Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.101 | current |
| txExcLocal NOTIFICATION-TYPE Exciter Local/Remote | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.102 | current |
| txExcRfOk NOTIFICATION-TYPE Exciter RF Ok | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.104 | current |
| txExcInputNoConnectHP1 NOTIFICATION-TYPE Exciter Input HP1 has no connected input signal | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.105 | current |
| txExcInputNoConnectLP1 NOTIFICATION-TYPE Exciter Input LP1 has no connected input signal | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.106 | current |
| txExcInputNoConnectHP2 NOTIFICATION-TYPE Exciter Input HP2 has no connected input signal | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.107 | current |
| txExcInputNoConnectLP2 NOTIFICATION-TYPE Exciter Input LP2 has no connected input signal | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.108 | current |
| txExcInputActiveHP1 NOTIFICATION-TYPE Exciter Input HP1 is active | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.109 | current |
| txExcInputActiveLP1 NOTIFICATION-TYPE Exciter Input LP1 is active | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.110 | current |
| txExcInputActiveHP2 NOTIFICATION-TYPE Exciter Input HP2 is active | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.111 | current |
| txExcInputActiveLP2 NOTIFICATION-TYPE Exciter Input LP2 is active | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.112 | current |
| txExcOn NOTIFICATION-TYPE Exciter On | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.113 | current |
| txExcRfOn NOTIFICATION-TYPE Exciter RF On | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.114 | current |
| txExcNoInput NOTIFICATION-TYPE Exciter has no valid input signal. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.115 | current |
| txExcRfLoop NOTIFICATION-TYPE Exciter RF loop | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.116 | current |
| txExcRfFail NOTIFICATION-TYPE Exciter RF Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.117 | current |
| txExcSelfTest NOTIFICATION-TYPE Exciter hardware self test | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.118 | current |
| txExcOutputOpen NOTIFICATION-TYPE Exciter output open | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.119 | current |
| txExcBoardTemperatureWarning NOTIFICATION-TYPE Exciter Board Temperature | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.120 | current |
| txExcFanWarning NOTIFICATION-TYPE Exciter has one faulty fan | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.121 | current |
| txExcFanFault NOTIFICATION-TYPE Both exciter fans are faulty. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.122 | current |
| txExcFifoWarning NOTIFICATION-TYPE Exciter Fifo | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.123 | current |
| txExcTestSignal NOTIFICATION-TYPE Exciter Testsignal Active | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.124 | current |
| txExcSFNDelay NOTIFICATION-TYPE Exciter SFN Delay Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.125 | current |
| txExcWrongDatarate NOTIFICATION-TYPE Exciter Wrong Datarate | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.126 | current |
| txExcMute NOTIFICATION-TYPE Exciter Mute | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.127 | current |
| txExcPPSFail NOTIFICATION-TYPE Exciter PPS Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.128 | current |
| txExcReferenceFail NOTIFICATION-TYPE Exciter Reference Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.129 | current |
| txExcMIPFail NOTIFICATION-TYPE Exciter MIP Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.130 | current |
| txExcInputAutomaticSwitchReady NOTIFICATION-TYPE Input automatic is ready. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.131 | current |
| txExcInputAutomaticChangedOver NOTIFICATION-TYPE Input automatic changed over. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.132 | current |
| txExcInputReseveMissing NOTIFICATION-TYPE Missing input, or automatic switching enabled with only one input present. Disable automatic switching or press reset fault to remove this warning. Monitoring of a second input will start automatically if two input signals have been detected. This event will be generated only if cmdExcExpectInputReserve is set to on(1). | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.133 | current |
| txOstSummaryFault NOTIFICATION-TYPE Outputstage Summary Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.200 | current |
| txOstSummaryWarning NOTIFICATION-TYPE Outputstage Summary Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.201 | current |
| txOstRfOn NOTIFICATION-TYPE Outputstage RF On | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.202 | current |
| txOstRfOk NOTIFICATION-TYPE Outputstage RF Ok | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.203 | current |
| txOstNoInput NOTIFICATION-TYPE Outputstage no input signal | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.204 | current |
| txOstRfWarning NOTIFICATION-TYPE Outputstage RF Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.205 | current |
| txOstReflectionWarning NOTIFICATION-TYPE Outputstage Reflection Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.206 | current |
| txOstRackWarning NOTIFICATION-TYPE Outputstage Rack Warning. At least one rack has an error pending. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.207 | current |
| txOstCoolingWarning NOTIFICATION-TYPE Outputstage Cooling Warning | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.208 | current |
| txOstRfFail NOTIFICATION-TYPE Outputstage RF Fail | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.209 | current |
| txOstReflectionFault NOTIFICATION-TYPE Outputstage Reflection Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.210 | current |
| txOstACFault NOTIFICATION-TYPE Outputstage AC Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.211 | current |
| txOstCoolingFault NOTIFICATION-TYPE Outputstage Cooling Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.212 | current |
| txOstCommFault NOTIFICATION-TYPE Outputstage Communication Fault | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.213 | current |
| txRackSumFault NOTIFICATION-TYPE Summary Fault at a designated rack. This event automatically leads to txOstRackWarning. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.300 | current |
| txRackSumWarning NOTIFICATION-TYPE Summary Warning at a designated rack. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.301 | current |
| txRackOn NOTIFICATION-TYPE The designated racks operation mode is on. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.302 | current |
| txRackGpiWarning NOTIFICATION-TYPE A warning on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller) | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.303 | current |
| txRackFan1Fault NOTIFICATION-TYPE The designated rack signals a fault of fan 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.304 | current |
| txRackFan2Fault NOTIFICATION-TYPE The designated rack signals a fault of fan 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.305 | current |
| txRackCoolingSumWarning NOTIFICATION-TYPE The designated rack signals a summary cooling warning. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.306 | current |
| txRackAmplifierSumFault NOTIFICATION-TYPE The designated rack signals at least one faulty amplifier. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.307 | current |
| txRackNoLink NOTIFICATION-TYPE No communication to the designated rack. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.308 | current |
| txRackGpiFault NOTIFICATION-TYPE A fault on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller) | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.309 | current |
| txRackTemperatureFault NOTIFICATION-TYPE The designated rack signals a temperature fault - temperature too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.310 | current |
| txRackACFault NOTIFICATION-TYPE The designated rack signals an AC (phase) fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.311 | current |
| txRackCoolingSumFault NOTIFICATION-TYPE The designated rack signals a summary cooling fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.312 | current |
| txRackTempFaultAbs1 NOTIFICATION-TYPE The designated rack signals a temperature fault of absorber 1. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.313 | current |
| txRackTempFaultAbs2 NOTIFICATION-TYPE The designated rack signals a temperature fault of absorber 2. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.314 | current |
| txRackDCFault NOTIFICATION-TYPE The designated rack signals a DC fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.315 | current |
| txRackRfOn NOTIFICATION-TYPE RF power is on. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.318 | current |
| txRackRfOk NOTIFICATION-TYPE RF power is ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.319 | current |
| txRackRfWarning NOTIFICATION-TYPE RF power decreased the warning threshold. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.320 | current |
| txRackRfFault NOTIFICATION-TYPE RF output power decreased the fault threshold. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.321 | current |
| txRackReflectionWarning NOTIFICATION-TYPE The reflected power increased the warning threshold | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.322 | current |
| txRackReflectionFault NOTIFICATION-TYPE The reflected power increased the fault threshold. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.323 | current |
| txRackProbeNotCalibrated NOTIFICATION-TYPE At least one probe is not calibrated. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.330 | current |
| txRackTemperatureWarning NOTIFICATION-TYPE Rack temperature exceeded the warning threshold. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.331 | current |
| txRackOvervoltProtectWarning NOTIFICATION-TYPE Overvoltage protection is out of order. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.335 | current |
| txAmpSumFault NOTIFICATION-TYPE The designated amplifier signals summary fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.400 | current |
| txAmpSumWarning NOTIFICATION-TYPE The designated amplifier signals summary warning. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.401 | current |
| txAmpPowerOn NOTIFICATION-TYPE The designated amplifiers power is on. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.402 | current |
| txAmpDCOk NOTIFICATION-TYPE The designated amplifiers DC is ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.403 | current |
| txAmpACOk NOTIFICATION-TYPE The designated amplifiers AC is ok. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.404 | current |
| txAmpRfInFail NOTIFICATION-TYPE The designated amplifier signals RF input fail. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.405 | current |
| txAmpRfFail NOTIFICATION-TYPE The designated amplifier signals RF fail. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.406 | current |
| txAmpReflectionFault NOTIFICATION-TYPE The designated amplifier signals a reflection fault. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.407 | current |
| txAmpTemperatureFault NOTIFICATION-TYPE The designated amplifier signals a temperature fault - temperature is too high. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.408 | current |
| txAmpTransistorFault NOTIFICATION-TYPE The designated amplifier signals at least one faulty transistor. | 1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.409 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| groupEvents OBJECT-GROUP This group includes all OIDs for event handling. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.1 | current |
| groupTxCommon OBJECT-GROUP Group for common transmitter objects | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.2 | current |
| groupEventsTxCommon NOTIFICATION-GROUP This group includes all alarm OIDs that are common for all reserve concepts. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.3 | current |
| groupDualDrive OBJECT-GROUP This group includes additional objects for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.4 | current |
| groupEventsDualDrive NOTIFICATION-GROUP This group includes additional events for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.5 | current |
| groupPowerReserve OBJECT-GROUP This group includes additional objects for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.6 | current |
| groupEventsPowerReserve NOTIFICATION-GROUP This group includes additional events for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.7 | current |
| groupCommonMP OBJECT-GROUP additional objects for medium/high power | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.8 | current |
| groupEventsCommonMP NOTIFICATION-GROUP additional events for medium/high power | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.9 | current |
| groupCommonNetCCU OBJECT-GROUP additional objects for transmitters with NetCCU | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.10 | current |
| groupEventsCommonNetCCU NOTIFICATION-GROUP additional events for transmitters with NetCCU | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.11 | current |
| groupOstBLogbook OBJECT-GROUP objects of logbook for output stage B | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.12 | current |
| groupSumProbe OBJECT-GROUP objects that are available only when sum probe exists | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.14 | current |
| groupProductInfo OBJECT-GROUP This group includes all OIDs for device product information. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.18 | current |
| groupAmpMeasureValues OBJECT-GROUP This group includes all OIDs amplifier measure values. Practically, these information are not important to customers, they are needed in manufactory. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.19 | current |
| groupEventsAmplifier NOTIFICATION-GROUP events from the amplifier (medium/high power only) | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.20 | current |
| groupRfProbes OBJECT-GROUP This group includes all OIDs regarding RF Probes. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.21 | current |
| groupDummyLoadRF OBJECT-GROUP This group includes all object types regarding probes from dummy load. The object types in this group are defined only when a dummy load measure point exists. This can occur in reserve concept active reserve only. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.22 | current |
| groupExcCommon OBJECT-GROUP Group for common exciter objects | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.23 | current |
| groupExcAdditionalSx800 OBJECT-GROUP Additional exciter objects for the Sx800 | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.24 | current |
| groupExcAdditionalSLx OBJECT-GROUP Additional exciter objects for the SLx and the Sx801 | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.25 | current |
| groupEventsExciter NOTIFICATION-GROUP events from the exciter | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.26 | current |
| groupExciterStatus OBJECT-GROUP Group for exciterStatusTable. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.27 | current |
| groupExciterPrecorrection OBJECT-GROUP Group for exciterPrecorrectionTable. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.28 | current |
| groupSLx OBJECT-GROUP object types that are relevant for SLx devices only | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.29 | current |
| groupObjectsACU OBJECT-GROUP objects from ACU | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.30 | current |
| groupIndependentRacks OBJECT-GROUP object types that are relevant for NX variants with independent racks only | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.31 | current |
| groupObjectsRE OBJECT-GROUP object types for the re-equip kit | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.32 | current |
| groupEventsControlExciter NOTIFICATION-GROUP additional events in case Sx801 is control exciter | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.34 | current |
| groupEventsAdditionalPowerSupply NOTIFICATION-GROUP Events that are available only when additionalPowerSupply is true. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.35 | current |
| groupObjsAdditionalPowerSupply OBJECT-GROUP Objects that are available only when additionalPowerSupply is true. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.36 | current |
| groupObjectsControlExciter OBJECT-GROUP additional objects in case Sx801 is control exciter | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.37 | current |
| groupObjectsSingleEnded OBJECT-GROUP Group for objects in case of SingleTx or DualDrive. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.38 | current |
| groupObjectsSx801Amplifier OBJECT-GROUP Objects for Sx801/SA801 amplifier status. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.39 | current |
| groupObsoleted OBJECT-GROUP obsoleted or deprecated objects | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.99 | obsolete |
| groupEventsObsoleted NOTIFICATION-GROUP obsoleted or deprecated events | 1.3.6.1.4.1.2566.127.1.2.167.4.5.1.100 | obsolete |
| rsXx8000DVBSingleTxMP MODULE-COMPLIANCE Reserve concept SingleTransmitter for Medium Power. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.1 | current |
| rsXx8000DVBDualDriveMP MODULE-COMPLIANCE Reserve concept DualDrive for Medium Power. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.2 | current |
| rsXx8000DVBPowerReserveMP MODULE-COMPLIANCE Reserve concept Active/Passive Reserve for Medium Power. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.3 | current |
| rsXx8000DVBSingleTxLP MODULE-COMPLIANCE Reserve concept Low Power SingleTransmitter with NetCCU, meaning there is a NetCCU and a LowPower exciter with one or more (to the exciter) connected amplifiers. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.5 | current |
| rsXx8000DVBDualDriveLP MODULE-COMPLIANCE Reserve concept DualDrive for Low Power. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.6 | current |
| rsXx8000DVBPowerReserveLP MODULE-COMPLIANCE Reserve concept Active/Passive Reserve for Low Power. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.7 | current |
| rsXx8000DVBSingleTxLPNoNetCCU MODULE-COMPLIANCE Reserve concept Low Power SingleTransmitter without NetCCU, meaning there is only a LowPower exciter with one or more (to the exciter) connected amplifiers. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.9 | current |
| rsXx8000DVBSLx MODULE-COMPLIANCE SLx device | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.10 | current |
| rsXx8000DVBExciterOnly MODULE-COMPLIANCE DVB Exciter of 8000 series in a 7000 environment or Program Exciter in a Sx801 Backup Exciter environment. | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.11 | current |
| rsXx8000DVBSx801ControlExciter MODULE-COMPLIANCE Sx801 as control exciter | 1.3.6.1.4.1.2566.127.1.2.167.4.5.3.12 | current |