RS-XX8000-COMMON-MIB
- Registered at
- 1.3.6.1.4.1.2566.127.1.2.1671.3.6.1.4.1.2566.149.1.163
- Last updated
- 2011-05-11 08:00
- Organization
- Rohde&Schwarz GmbH & Co. KG
- Revisions
- 2011-05-11 08:00, 2011-02-23 08:00, 2010-05-06 08:00, 2009-12-08 08:00, 2009-09-10 08:00, 2009-06-26 09:00, 2009-06-03 09:00, 2009-04-30 09:00, 2009-03-13 09:00, 2009-02-10 16:00, 2008-12-12 14:00, 2008-10-20 09:00, 2008-10-10 09:00, 2008-09-30 09:00, 2008-09-03 09:00, 2008-07-23 15:30, 2008-06-16 09:00, 2008-06-10 08:00, 2008-06-02 10:30, 2008-05-13 15:00, 2008-04-23 11:00, 2008-02-18 13:30, 2008-02-11 12:00, 2008-02-06 12:00, 2007-12-17 12:00, 2007-10-02 10:00, 2007-09-04 13:00, 2007-06-29 10:00, 2007-05-16 10:00, 2007-03-14 10:00, 2006-12-21 10:00, 2006-11-20 10:00
- Namespace
- rs
- Source file
RS-XX8000-COMMON-MIB- Digest
sha256:974e921aff7ecc84f744feaa51782c8775507e366c3f313232f8c21cb0e6adcd
Description
This MIB defines general objects of XX8000 transmitting systems from Rohde & Schwarz. Use this MIB for things all transmitters support via SNMP, e.g.: - product information - installation / configuration issues (trapsinks, managers aso.) The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB.
Contact
Torsten Huebscher Department 7TS2 Broadcasting Division Muehldorfstrasse 15 81671 Munich, Germany torsten.huebscher@rohde-schwarz.com
Imports
| From | Symbols |
|---|---|
| RS-COMMON-MIB | rsProdBroadcastTransmitter, rsRegModules |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
RS-COMMON-MIB RS-XX8000-COMMON-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2566.149.1.163.3 | rsXx8000DvbTxMibModule | RS-XX8000-DVB-TX-MIB |
| 1.3.6.1.4.1.2566.127.1.2.167.4 | rsXx8000DvbTx | RS-XX8000-DVB-TX-MIB |
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AtvStandard TEXTUAL-CONVENTION The ATV standards. | current | |||
| EqualizerCalibrationState TEXTUAL-CONVENTION possible precorrection equalizer calibration states | current | |||
| EventClass TEXTUAL-CONVENTION These are the levels of events a transmitter has. Info(3): Are events which only inform about changes, e.g. 'local/remote' or 'reboot of the control unit'. They don't affect the transmission. Warning(2): Are minor problems which do not influence transmission itself, but may cause a bigger problem when no action is taken, e.g. 'RF Loop Program'. Warnings may appear and disappear without the need of acknowledgment. Fault(1): Have a direct impact on the transmission, e.g. 'failure power supply'. Faults never disappear without acknowledgment. | current | |||
| EventMask TEXTUAL-CONVENTION Enables / Disables this event. enable(1) --> active, will be sent in case the event occurs disable(2) --> inactive, will not be sent in case the event occurs. | current | |||
| EventMaxEntryNumber TEXTUAL-CONVENTION The maximum number of events. This is used in other MIBs as a placeholder. | current | |||
| EventPriority TEXTUAL-CONVENTION The priority of the event. Users can freely set this value in range 0..255. | current | |||
| EventState TEXTUAL-CONVENTION The current state of an event: active(1) --> event is active (coming) inactive(2) --> event is inactive (going) This is used in all logbooks and in all event handling tables. | current | |||
| FailDelayMode TEXTUAL-CONVENTION The mode how fail delay is handled. always(1) - the fail delay action is always carried out after the user specified fail delay time. ifQualified(2) - the fail delay action is carried out after the user specified fail delay time only if the FailDelayStatus is ok(3). Otherwise (Fail DelayStatus warning(2)) 30 minutes after GPS was lost a reference fault is signaled and the input is muted. | current | |||
| FailDelayStatus TEXTUAL-CONVENTION The current state of time drift prediction. off(1) - not used warning(2) - Availability of GPS not sufficient for time drift prediction ok(3) - Time drift prediction is functional. | current | |||
| FloatingPoint TEXTUAL-CONVENTION FloatingPoint provides a way of representing non-integer numbers in SNMP. Numbers are represented as a string of ASCII characters in the natural way. So for example, '3', '3.142' and '0.3142E1' are all valid numbers. The syntax for the string is as follows. [] enclose an optional element, | is the separator for a set of alternatives. () enclose syntax which is to be viewed as a unit. FloatingPoint ::= [Sign] (Float1 | Float2 | DigitSequence) [ExponentPart] Float1 ::= DigitSequence '.' [DigitSequence] Float2 ::= '.' DigitSequence DigitSequence ::= Digit [DigitSequence] ExponentPart ::= ('e' | 'E') [Sign] DigitSequence Digit ::= '0'..'9' Sign ::= '+' | '-' | current | |||
| IndexAB TEXTUAL-CONVENTION The value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) for alarms. This is a helper column. | current | |||
| IndexAmplifier TEXTUAL-CONVENTION This is used to display a designated amplifier. | current | |||
| IndexProgram TEXTUAL-CONVENTION This is used for Nplus1 systems to indicate a program sent out (logical view). ProgramRes(1) is the reserve program, program1(2) to program8(9) are the main programs. In difference to the physical view, programRes(1) has no special parameters available. Furthermore it has no priority. | current | |||
| IndexRack TEXTUAL-CONVENTION This is used for systems with more than 1 rack to display a designated rack. | current | |||
| IndexTransmitter TEXTUAL-CONVENTION This is used for Nplus1 systems to indicate a transmitter (physical view). TransmitterB(1) is the reserve transmitter, transmitterA1(2) to transmitterA8(9) are the main transmitter. In difference to the logical view, transmitterB(1) has special parameters available. | current | |||
| InputSource TEXTUAL-CONVENTION input source selection type | current | |||
| LockState TEXTUAL-CONVENTION This is for carrier locking. | current | |||
| LogbookEntryMessagesExcATV TEXTUAL-CONVENTION Inserted information in the logbook of ATV exciters. This is obsolete! Please use LogbookEntryMessagesExcTv! | obsolete | |||
| LogbookEntryMessagesExcDVB TEXTUAL-CONVENTION Inserted information in the logbook of DVB exciters. This is obsolete! Please use LogbookEntryMessagesExcTv! | obsolete | |||
| LogbookEntryMessagesExcFM TEXTUAL-CONVENTION Inserted information in the logbook of FM exciters. | current | |||
| LogbookEntryMessagesExcTv TEXTUAL-CONVENTION Inserted information in the logbook of TV exciters. | current | |||
| LogbookEntryMessagesNSU TEXTUAL-CONVENTION Inserted information in the logbook of Nplus1-Switchoverunit. | current | |||
| LogbookEntryMessagesNetCCU TEXTUAL-CONVENTION Inserted information in the logbook of NetCCU. | current | |||
| LogbookEntryMessagesOST TEXTUAL-CONVENTION Inserted information in the logbook of outputstage. | current | |||
| LogbookEntryMessagesXV703 TEXTUAL-CONVENTION Inserted information in the logbook of XV703 transposers. | current | |||
| LogbookEntrySlope TEXTUAL-CONVENTION These are the information which are inserted in the logbook. | current | |||
| LogbookMaxEntryNumber TEXTUAL-CONVENTION The maximum number of entries in a logbook. This is used in other MIBs as a placeholder. | current | |||
| ProdInfoModuleNameFm TEXTUAL-CONVENTION The product information module names for FM. | current | |||
| ProdInfoModuleNameNsu TEXTUAL-CONVENTION The product information module names for NSU. | current | |||
| ProdInfoModuleNameTv TEXTUAL-CONVENTION The product information module names for TV. | current | |||
| ReadableString TEXTUAL-CONVENTION An octet string containing a human-readable string. This string may have originally been encoded as specified in EN 300 468 Annex A, but this is not a requirement. To maintain generality, the information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in RFC2279. Control codes are interpreted as specified in EN 300 468 Annex A, section A.1. The interpretation of other control codes is undefined. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character/code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. | current | |||
| SwitchOnOff TEXTUAL-CONVENTION This is for all on/off-switches. | current | |||
| Sx801AmplifierState TEXTUAL-CONVENTION Description. | current | |||
| TimeOfDay TEXTUAL-CONVENTION A time of day specification. octets contents range ------ -------- ----- 1 hour 0..23 2 minute 0..59 3 second 0..59 For example, 1:30:17 PM would be displayed as 13:30:17. The second can be omitted. | current | |||
| Trigger TEXTUAL-CONVENTION Trigger for starting a certain action. idle(1) --> ready, do nothing trigger(2) --> do now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything. | current | |||
| TvStandard TEXTUAL-CONVENTION The TV standards. The value 'inconsistent' cannot be written. It is shown only when switching from one standard to another in between. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rsXx8000 OBJECT-IDENTITY The subtree for all transmitters of series 8000. | 1.3.6.1.4.1.2566.127.1.2.167 | current | ||
| rsXx8000Common OBJECT-IDENTITY This is the subtree for values which every equipement of series 8000 suports. | 1.3.6.1.4.1.2566.127.1.2.167.1 | current | ||
| rsXx8000CommonObjs OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1 | |||
| productInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1 | |||
| serialNumber OBJECT-TYPE The serial number of the device. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.2 | ReadableString | read-only | current |
| identNumberSW OBJECT-TYPE The Rohde&Schwarz identification number of the software, for example 2094.2090.02. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.3 | ReadableString | read-only | current |
| versionNumberSW OBJECT-TYPE The Rohde&Schwarz revision number of the software, for example 1.2.1. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.4 | ReadableString | read-only | current |
| identNumberHW OBJECT-TYPE The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU). | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.5 | ReadableString | read-only | current |
| versionNumberHW OBJECT-TYPE The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.6 | ReadableString | read-only | current |
| snmpConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2 | |||
| trapSinkTable OBJECT-TYPE This table is for configuration of trapsinks - the IP-addresses where traps/informs are sent to. This table gives you possibility for easier remote configuration of trapsinks. Another way, which is predefined by IETF, is to use the MIBs SNMP-TARGET and SNMP-NOTIFICATION. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2 | not-accessible | current | |
| trapSinkEntry OBJECT-TYPE An entry for a trapsink. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1 | not-accessible | current | |
| trapSinkNumber OBJECT-TYPE The arbitrary number in the list. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.1 | Integer32 (1..5) | not-accessible | current |
| trapSinkVersion OBJECT-TYPE The SNMP-version of sent out alarm. 1: v1Trap 2: v2Trap 3: v2Inform | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.2 | INTEGER {v1Trap(1), v2Trap(2), v2Inform(3)} | read-write | current |
| trapSinkAddress OBJECT-TYPE The IP-Address of the SNMP manager to which the alarms are sent to. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.3 | IpAddress | read-write | current |
| trapSinkPort OBJECT-TYPE The port of the SNMP manager to which the alarms are sent to. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.4 | Integer32 (1..65535) | read-write | current |
| trapSinkCommunity OBJECT-TYPE community used in alarm | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.5 | ReadableString | read-write | current |
| trapSinkInformRetry OBJECT-TYPE only used for informs: number of times to resend the inform | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.6 | Integer32 (1..255) | read-write | current |
| trapSinkInformTimeout OBJECT-TYPE only used for informs: timeout between retries | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.7 | Integer32 (1..255) | read-write | current |
| trapSinkInformUnacknowledged OBJECT-TYPE only used for informs: maximum number of waiting informs if this is reached, the oldest pending inform is discarded | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.8 | Integer32 (1..255) | read-write | obsolete |
| trapSinkUse OBJECT-TYPE on/off-switch for this sink | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.9 | TruthValue | read-write | current |
| sendTestTrap OBJECT-TYPE 1: idle 2: Agent generates the trap 'testTrap', which is useful when checking the connection between agent (NetCCU) and your trapsink. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.3 | Trigger | read-write | current |
| irtTrapsAllOn OBJECT-TYPE This switches all IRT-traps on - traps for all events are sent out. In detail, this means in the IRT-MIBs under branches *EventEnable all OIDs are set to 1. Caution! Setting this value influences remote controlling of devices. Too many alarms may flood your network. Use this only for testing - for operation, we suggest switch on only a few important traps. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.4 | Trigger | read-write | current |
| irtTrapsAllOff OBJECT-TYPE This switches all IRT-traps off - no traps are sent out. In detail, this means in the IRT-MIBs under branches *EventEnable all OIDs are set to 2. Note: This is typically set when using only R&S-MIBs and you don't need IRT-MIBs. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.5 | Trigger | read-write | current |
| rsTrapsAllOn OBJECT-TYPE This switches all R&S-traps on - traps for all events (info, warning, fault) are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all OIDs are set to 1. Caution! Enabling all traps is not recommended! Caution! Setting this value influences remote controlling of devices! Too many alarms may flood your network. Use this only for testing - for operation, we suggest switch on only a few important traps. Caution! This enables absolutely all R&S alarms! Make sure you can handle it (network speed, routers, firewalls, NOC database performance etc.). | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.6 | Trigger | read-write | current |
| rsTrapsAllOff OBJECT-TYPE This switches all R&S-traps off - no traps are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all OIDs are set to 2. Note: This is typically set when using only IRT-MIBs and you don't need R&S-MIBs. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.7 | Trigger | read-write | current |
| rsTrapsAllFaultsOn OBJECT-TYPE This switches all R&S-traps for faults on - traps for all 'faults' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'fault'-OIDs are set to '1'. These traps include the value 'fault(1)' in binding 'eventAlarmClass'. Note: This is the recommended setting when using R&S-MIBs. It gives you an overview of the device state. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.8 | Trigger | read-write | current |
| rsTrapsAllFaultsOff OBJECT-TYPE This switches all R&S-traps for faults off - no traps for 'faults' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'fault'-OIDs are set to '2'. These traps include the value 'fault(1)' in binding 'eventAlarmClass'. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.9 | Trigger | read-write | current |
| rsTrapsAllWarningsOn OBJECT-TYPE This switches all R&S-traps for warnings on - traps for all 'warnings' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'warning'-OIDs are set to '1'. These traps include the value 'warning(2)' in binding 'eventAlarmClass'. Note: This is the recommended setting when using R&S-MIBs and you want much more informations from the device than only faults. Caution! This enables lots of alarms. Make sure you can handle it (network speed, NOC database performance etc.)... | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.10 | Trigger | read-write | current |
| rsTrapsAllWarningsOff OBJECT-TYPE This switches all R&S-traps for warnings off - no traps for 'warnings' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'warning'-OIDs are set to '2'. These traps include the value 'warning(2)' in binding 'eventAlarmClass'. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.11 | Trigger | read-write | current |
| transmitterConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3 | |||
| dateTime OBJECT-TYPE The date and time for the transmitter. Notes: Deci-seconds different from 0 are ignored. The range of distance from UTC is -12h..+14h. Omitting the optional UTC fields in a set-request results in keeping the old UTC offset values. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.1 | DateAndTime | read-write | current |
| ntp OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2 | |||
| ntpMode OBJECT-TYPE Configures the working mode of the NTP client. disabled: no ntp synchronisation will be done step: the time will synchronized every NTP sync-time unknown: NTP mode is currently not determinable. This value must not be written. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.1 | INTEGER {unknown(1), disabled(2), stepAdjust(4)} | read-write | current |
| ntpSyncTimeInterval OBJECT-TYPE Set the intervall, how often the NTP client will be synchronized to the NTP server. Note: this is useful in step mode only . | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.2 | Integer32 (6..1440) | read-write | current |
| ntpServerAddrTable OBJECT-TYPE Table with server adresses. Currently maximal one entry is allowed. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3 | not-accessible | current | |
| ntpServerAddrEntry OBJECT-TYPE An entry for a ntpServerAddrTable. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1 | not-accessible | current | |
| ntpServerAddrIdx OBJECT-TYPE index for table entry. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.1 | Integer32 (1) | not-accessible | current |
| ntpServerAddress OBJECT-TYPE host name or IP address of server. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.2 | ReadableString | read-write | current |
| ntpState OBJECT-TYPE Shows the actual state of the NTP synchronisation. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.4 | INTEGER {unknown(1), disabled(2), enabled(3), notRunning(4), syncFailed(5), synchronizing(6), syncOk(7)} | read-only | current |
| ntpLastSync OBJECT-TYPE The date/time of the last successful synchronisation. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.5 | DateAndTime | read-only | current |
| swMaintenance OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5 | |||
| restart OBJECT-TYPE Restart the software of transmitter's control unit. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.1 | Trigger | read-write | current |
| swUpdate OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5 | |||
| swUpdateStart OBJECT-TYPE Start software update tool at transmitter side in manual mode. The PC tool can only connect to transmitter's control unit if the software update tool on the transmitter is started. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.2 | Trigger | read-write | current |
| swUpdateMode OBJECT-TYPE Run mode of the software update tool at the transmitter side. manual: Software update can be started with the Start button. It will stop automaticly after an idle period of 90 seconds. permanent: Software update is always running and will never stop. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.3 | INTEGER {manual(1), permanent(2)} | read-write | current |
| swUpdateDeviceName OBJECT-TYPE The Device Name is dedicated to this control unit. It will be shown in the software update tool on the PC to differ devices. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.4 | ReadableString (SIZE(0..30)) | read-write | current |
| swUpdateDeviceGroup OBJECT-TYPE The Device Group can be used to separate devices in large networks. It must match the Device Group in software update tool on the PC. | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.5 | ReadableString (SIZE(0..30)) | read-write | current |
| rsXx8000CommonEvents OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.2 | |||
| rsXx8000EventsV2 OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0 | |||
| eventTx OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10 | |||
| eventsTxV2 OBJECT-IDENTITY Compatibility to SMIv1. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0 | current | ||
| eventsTxTable OBJECT-TYPE This table contains necessary information for handling alarms. For each alarm you have the following information: - name (get), - mask to enable/disable sending out (set/get), - priority (set/get) and - the current state (get only). | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1 | not-accessible | current | |
| eventsTxEntry OBJECT-TYPE An event entry always consists of 3 values: - name: an enumerated list of all possible notifications - mask: the corresponding mask (enable/disable) - priority: the corresponding priority (value in range 0..255) - event: the event itself (active/inactive) | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1 | not-accessible | current | |
| eventTxNameIdx OBJECT-TYPE The event number as integer. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.1 | EventMaxEntryNumber | not-accessible | current |
| eventTxName OBJECT-TYPE The event number as integer and the value as readable text. The enumeration correlates with the notifications under eventsTxV2. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.2 | INTEGER {swUpdateStarted(1), ntpSyncFailed(2)} | read-only | current |
| eventTxMask OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.3 | EventMask | read-write | current |
| eventTxPriority OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.4 | EventPriority | read-write | current |
| eventTxEvent OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.5 | EventState | read-only | current |
| eventHistory OBJECT-IDENTITY Information about sent out events. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1 | current | ||
| counterEvents OBJECT-TYPE The total number of traps sent out. This is an increasing value. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.1 | Counter32 | read-only | current |
| eventHistoryTable OBJECT-TYPE The table of the last 100 messages sent out. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2 | not-accessible | current | |
| eventHistoryEntry OBJECT-TYPE An event entry. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1 | not-accessible | current | |
| eventHistoryNumber OBJECT-TYPE The trap number. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.1 | Integer32 (1..2147483647) | not-accessible | current |
| eventHistoryModule OBJECT-TYPE This column indicates the physical module the corresponding message is for. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.2 | INTEGER {switchoverUnit(1), netccu(2), exciterA(3), exciterB(4), outputstageA(5), outputstageB(6), dvbReceiver(7), pumpA(8), pumpB(9), antenna(10), gps(11), dvbRecMon(12), gpParIO(13), program(14)} | read-only | current |
| eventHistoryEvent OBJECT-TYPE This column indicates the event. In correlation with column eventHistoryModule, you can see the name of the event here. For this, you need to have a look at the event definitions of the corresponding MIB. Example: For a DVB transmitter an entry in eventHistoryModule is netccu(2) and the value in eventHistoryEvent is 1. A look at eventsTxV2 of RS-XX8000-DVB-TX-MIB shows, 1 is txSummaryFault. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.3 | Integer32 | read-only | current |
| eventHistoryEventState OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.4 | EventState | read-only | current |
| eventHistoryEventDate OBJECT-TYPE This column indicates the date and time of the event. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.5 | DateAndTime | read-only | current |
| eventHistoryTx OBJECT-TYPE The transmitter index in case of NTx or Np1 systems. For variants with one transmitter only (SingleTx) this index is always transmitterB(1). | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.101 | IndexTransmitter | read-only | current |
| eventMapObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3 | |||
| eventAlarmPriority OBJECT-TYPE This OID holds the value for the priority when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.1 | EventPriority | accessible-for-notify | current |
| eventAlarmClass OBJECT-TYPE See TextualConvention for details. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.2 | EventClass | accessible-for-notify | current |
| eventEvent OBJECT-TYPE This OID holds the value for the event itself when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.3 | EventState | accessible-for-notify | current |
| indexTransmitter OBJECT-TYPE This OID holds the value for the transmitter when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.4 | IndexTransmitter | accessible-for-notify | current |
| indexAB OBJECT-TYPE This OID holds the value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.5 | IndexAB | accessible-for-notify | current |
| indexRack OBJECT-TYPE This OID holds the value for the rack when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.6 | IndexRack | accessible-for-notify | current |
| indexAmplifier OBJECT-TYPE This OID holds the value for the amplifier when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.7 | IndexAmplifier | accessible-for-notify | current |
| indexProgram OBJECT-TYPE This object holds the value for the program when sending out a notification. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.8 | IndexProgram | accessible-for-notify | current |
| rsXx8000CommonConf OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.3 | |||
| rsXx8000CommonGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1 | |||
| rsXx8000CommonCompls OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.167.1.3.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| testTrap NOTIFICATION-TYPE This trap is sent to check whether the trapsink is receiving any traps from this agent. To trigger this trap, set 'sendTestTrap' to '2'. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.1 | current |
| swUpdateStarted NOTIFICATION-TYPE Software update started. The PC tool can only connect to transmitter's control unit if the software update tool on the transmitter is started. It uses the network 17 (TCP and UDP). | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.1 | current |
| ntpSyncFailed NOTIFICATION-TYPE NTP synchronisation failed. | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| groupNotifyTest NOTIFICATION-GROUP test notifications. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.1 | current |
| groupNotify NOTIFICATION-GROUP notifications for all transmitters. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.2 | current |
| groupEventTest OBJECT-GROUP The objects sent with testTrap. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.6 | current |
| groupEventHistory OBJECT-GROUP Contains all objects from 'eventHistory'. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.8 | current |
| groupEventObjects OBJECT-GROUP Contains all objects from 'eventMapObjects'. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.9 | current |
| groupProductInformation OBJECT-GROUP Contains all objects from 'productInformation' (R&S typeplate). | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.11 | current |
| groupSnmpConfig OBJECT-GROUP Contains all objects from 'snmpConfig'. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.12 | current |
| groupTransmitterConfig OBJECT-GROUP objects from 'transmitterConfig'. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.13 | current |
| groupNTP OBJECT-GROUP objects from 'ntp' | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.14 | current |
| groupSwMaintenance OBJECT-GROUP objects from 'swMaintenance' | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.15 | current |
| groupNotifyNTP NOTIFICATION-GROUP Notifications from the NTP client. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.16 | current |
| groupObsoletedObjects OBJECT-GROUP Description. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.17 | obsolete |
| xx8000BasicCompliance MODULE-COMPLIANCE The compliance statement for XX8000 entities which implement this MIB module. | 1.3.6.1.4.1.2566.127.1.2.167.1.3.2.1 | current |