MIBs Depot

RS-XX8000-COMMON-MIB

Registered at
1.3.6.1.4.1.2566.127.1.2.167
1.3.6.1.4.1.2566.149.1.163
Last updated
2011-05-11 08:00
Organization
Rohde&Schwarz GmbH & Co. KG
Revisions
2011-05-11 08:00, 2011-02-23 08:00, 2010-05-06 08:00, 2009-12-08 08:00, 2009-09-10 08:00, 2009-06-26 09:00, 2009-06-03 09:00, 2009-04-30 09:00, 2009-03-13 09:00, 2009-02-10 16:00, 2008-12-12 14:00, 2008-10-20 09:00, 2008-10-10 09:00, 2008-09-30 09:00, 2008-09-03 09:00, 2008-07-23 15:30, 2008-06-16 09:00, 2008-06-10 08:00, 2008-06-02 10:30, 2008-05-13 15:00, 2008-04-23 11:00, 2008-02-18 13:30, 2008-02-11 12:00, 2008-02-06 12:00, 2007-12-17 12:00, 2007-10-02 10:00, 2007-09-04 13:00, 2007-06-29 10:00, 2007-05-16 10:00, 2007-03-14 10:00, 2006-12-21 10:00, 2006-11-20 10:00
Namespace
rs
Source file
RS-XX8000-COMMON-MIB
Digest
sha256:974e921aff7ecc84f744feaa51782c8775507e366c3f313232f8c21cb0e6adcd

Description

This MIB defines general objects of XX8000 transmitting systems from Rohde & Schwarz. Use this MIB for things all transmitters support via SNMP, e.g.: - product information - installation / configuration issues (trapsinks, managers aso.) The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB.

Contact

Torsten Huebscher Department 7TS2 Broadcasting Division Muehldorfstrasse 15 81671 Munich, Germany torsten.huebscher@rohde-schwarz.com

Imports

FromSymbols
RS-COMMON-MIBrsProdBroadcastTransmitter, rsRegModules
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

RS-COMMON-MIB
RS-XX8000-COMMON-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.2566.149.1.163.3rsXx8000DvbTxMibModuleRS-XX8000-DVB-TX-MIB
1.3.6.1.4.1.2566.127.1.2.167.4rsXx8000DvbTxRS-XX8000-DVB-TX-MIB

Textual conventions

NameOIDSyntaxAccessStatus
AtvStandard
TEXTUAL-CONVENTION
The ATV standards.
current
EqualizerCalibrationState
TEXTUAL-CONVENTION
possible precorrection equalizer calibration states
current
EventClass
TEXTUAL-CONVENTION
These are the levels of events a transmitter has. Info(3): Are events which only inform about changes, e.g. 'local/remote' or 'reboot of the control unit'. They don't affect the transmission. Warning(2): Are minor problems which do not influence transmission itself, but may cause a bigger problem when no action is taken, e.g. 'RF Loop Program'. Warnings may appear and disappear without the need of acknowledgment. Fault(1): Have a direct impact on the transmission, e.g. 'failure power supply'. Faults never disappear without acknowledgment.
current
EventMask
TEXTUAL-CONVENTION
Enables / Disables this event. enable(1) --> active, will be sent in case the event occurs disable(2) --> inactive, will not be sent in case the event occurs.
current
EventMaxEntryNumber
TEXTUAL-CONVENTION
The maximum number of events. This is used in other MIBs as a placeholder.
current
EventPriority
TEXTUAL-CONVENTION
The priority of the event. Users can freely set this value in range 0..255.
current
EventState
TEXTUAL-CONVENTION
The current state of an event: active(1) --> event is active (coming) inactive(2) --> event is inactive (going) This is used in all logbooks and in all event handling tables.
current
FailDelayMode
TEXTUAL-CONVENTION
The mode how fail delay is handled. always(1) - the fail delay action is always carried out after the user specified fail delay time. ifQualified(2) - the fail delay action is carried out after the user specified fail delay time only if the FailDelayStatus is ok(3). Otherwise (Fail DelayStatus warning(2)) 30 minutes after GPS was lost a reference fault is signaled and the input is muted.
current
FailDelayStatus
TEXTUAL-CONVENTION
The current state of time drift prediction. off(1) - not used warning(2) - Availability of GPS not sufficient for time drift prediction ok(3) - Time drift prediction is functional.
current
FloatingPoint
TEXTUAL-CONVENTION
FloatingPoint provides a way of representing non-integer numbers in SNMP. Numbers are represented as a string of ASCII characters in the natural way. So for example, '3', '3.142' and '0.3142E1' are all valid numbers. The syntax for the string is as follows. [] enclose an optional element, | is the separator for a set of alternatives. () enclose syntax which is to be viewed as a unit. FloatingPoint ::= [Sign] (Float1 | Float2 | DigitSequence) [ExponentPart] Float1 ::= DigitSequence '.' [DigitSequence] Float2 ::= '.' DigitSequence DigitSequence ::= Digit [DigitSequence] ExponentPart ::= ('e' | 'E') [Sign] DigitSequence Digit ::= '0'..'9' Sign ::= '+' | '-'
current
IndexAB
TEXTUAL-CONVENTION
The value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) for alarms. This is a helper column.
current
IndexAmplifier
TEXTUAL-CONVENTION
This is used to display a designated amplifier.
current
IndexProgram
TEXTUAL-CONVENTION
This is used for Nplus1 systems to indicate a program sent out (logical view). ProgramRes(1) is the reserve program, program1(2) to program8(9) are the main programs. In difference to the physical view, programRes(1) has no special parameters available. Furthermore it has no priority.
current
IndexRack
TEXTUAL-CONVENTION
This is used for systems with more than 1 rack to display a designated rack.
current
IndexTransmitter
TEXTUAL-CONVENTION
This is used for Nplus1 systems to indicate a transmitter (physical view). TransmitterB(1) is the reserve transmitter, transmitterA1(2) to transmitterA8(9) are the main transmitter. In difference to the logical view, transmitterB(1) has special parameters available.
current
InputSource
TEXTUAL-CONVENTION
input source selection type
current
LockState
TEXTUAL-CONVENTION
This is for carrier locking.
current
LogbookEntryMessagesExcATV
TEXTUAL-CONVENTION
Inserted information in the logbook of ATV exciters. This is obsolete! Please use LogbookEntryMessagesExcTv!
obsolete
LogbookEntryMessagesExcDVB
TEXTUAL-CONVENTION
Inserted information in the logbook of DVB exciters. This is obsolete! Please use LogbookEntryMessagesExcTv!
obsolete
LogbookEntryMessagesExcFM
TEXTUAL-CONVENTION
Inserted information in the logbook of FM exciters.
current
LogbookEntryMessagesExcTv
TEXTUAL-CONVENTION
Inserted information in the logbook of TV exciters.
current
LogbookEntryMessagesNSU
TEXTUAL-CONVENTION
Inserted information in the logbook of Nplus1-Switchoverunit.
current
LogbookEntryMessagesNetCCU
TEXTUAL-CONVENTION
Inserted information in the logbook of NetCCU.
current
LogbookEntryMessagesOST
TEXTUAL-CONVENTION
Inserted information in the logbook of outputstage.
current
LogbookEntryMessagesXV703
TEXTUAL-CONVENTION
Inserted information in the logbook of XV703 transposers.
current
LogbookEntrySlope
TEXTUAL-CONVENTION
These are the information which are inserted in the logbook.
current
LogbookMaxEntryNumber
TEXTUAL-CONVENTION
The maximum number of entries in a logbook. This is used in other MIBs as a placeholder.
current
ProdInfoModuleNameFm
TEXTUAL-CONVENTION
The product information module names for FM.
current
ProdInfoModuleNameNsu
TEXTUAL-CONVENTION
The product information module names for NSU.
current
ProdInfoModuleNameTv
TEXTUAL-CONVENTION
The product information module names for TV.
current
ReadableString
TEXTUAL-CONVENTION
An octet string containing a human-readable string. This string may have originally been encoded as specified in EN 300 468 Annex A, but this is not a requirement. To maintain generality, the information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in RFC2279. Control codes are interpreted as specified in EN 300 468 Annex A, section A.1. The interpretation of other control codes is undefined. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character/code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
current
SwitchOnOff
TEXTUAL-CONVENTION
This is for all on/off-switches.
current
Sx801AmplifierState
TEXTUAL-CONVENTION
Description.
current
TimeOfDay
TEXTUAL-CONVENTION
A time of day specification. octets contents range ------ -------- ----- 1 hour 0..23 2 minute 0..59 3 second 0..59 For example, 1:30:17 PM would be displayed as 13:30:17. The second can be omitted.
current
Trigger
TEXTUAL-CONVENTION
Trigger for starting a certain action. idle(1) --> ready, do nothing trigger(2) --> do now A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
current
TvStandard
TEXTUAL-CONVENTION
The TV standards. The value 'inconsistent' cannot be written. It is shown only when switching from one standard to another in between.
current

Objects

NameOIDSyntaxAccessStatus
rsXx8000
OBJECT-IDENTITY
The subtree for all transmitters of series 8000.
1.3.6.1.4.1.2566.127.1.2.167current
rsXx8000Common
OBJECT-IDENTITY
This is the subtree for values which every equipement of series 8000 suports.
1.3.6.1.4.1.2566.127.1.2.167.1current
rsXx8000CommonObjs
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1
productInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.1
serialNumber
OBJECT-TYPE
The serial number of the device.
1.3.6.1.4.1.2566.127.1.2.167.1.1.1.2ReadableStringread-onlycurrent
identNumberSW
OBJECT-TYPE
The Rohde&Schwarz identification number of the software, for example 2094.2090.02.
1.3.6.1.4.1.2566.127.1.2.167.1.1.1.3ReadableStringread-onlycurrent
versionNumberSW
OBJECT-TYPE
The Rohde&Schwarz revision number of the software, for example 1.2.1.
1.3.6.1.4.1.2566.127.1.2.167.1.1.1.4ReadableStringread-onlycurrent
identNumberHW
OBJECT-TYPE
The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU).
1.3.6.1.4.1.2566.127.1.2.167.1.1.1.5ReadableStringread-onlycurrent
versionNumberHW
OBJECT-TYPE
The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03.
1.3.6.1.4.1.2566.127.1.2.167.1.1.1.6ReadableStringread-onlycurrent
snmpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.2
trapSinkTable
OBJECT-TYPE
This table is for configuration of trapsinks - the IP-addresses where traps/informs are sent to. This table gives you possibility for easier remote configuration of trapsinks. Another way, which is predefined by IETF, is to use the MIBs SNMP-TARGET and SNMP-NOTIFICATION.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2not-accessiblecurrent
trapSinkEntry
OBJECT-TYPE
An entry for a trapsink.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1not-accessiblecurrent
trapSinkNumber
OBJECT-TYPE
The arbitrary number in the list.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.1Integer32 (1..5)not-accessiblecurrent
trapSinkVersion
OBJECT-TYPE
The SNMP-version of sent out alarm. 1: v1Trap 2: v2Trap 3: v2Inform
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.2INTEGER {v1Trap(1), v2Trap(2), v2Inform(3)}read-writecurrent
trapSinkAddress
OBJECT-TYPE
The IP-Address of the SNMP manager to which the alarms are sent to.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.3IpAddressread-writecurrent
trapSinkPort
OBJECT-TYPE
The port of the SNMP manager to which the alarms are sent to.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.4Integer32 (1..65535)read-writecurrent
trapSinkCommunity
OBJECT-TYPE
community used in alarm
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.5ReadableStringread-writecurrent
trapSinkInformRetry
OBJECT-TYPE
only used for informs: number of times to resend the inform
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.6Integer32 (1..255)read-writecurrent
trapSinkInformTimeout
OBJECT-TYPE
only used for informs: timeout between retries
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.7Integer32 (1..255)read-writecurrent
trapSinkInformUnacknowledged
OBJECT-TYPE
only used for informs: maximum number of waiting informs if this is reached, the oldest pending inform is discarded
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.8Integer32 (1..255)read-writeobsolete
trapSinkUse
OBJECT-TYPE
on/off-switch for this sink
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.9TruthValueread-writecurrent
sendTestTrap
OBJECT-TYPE
1: idle 2: Agent generates the trap 'testTrap', which is useful when checking the connection between agent (NetCCU) and your trapsink.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.3Triggerread-writecurrent
irtTrapsAllOn
OBJECT-TYPE
This switches all IRT-traps on - traps for all events are sent out. In detail, this means in the IRT-MIBs under branches *EventEnable all OIDs are set to 1. Caution! Setting this value influences remote controlling of devices. Too many alarms may flood your network. Use this only for testing - for operation, we suggest switch on only a few important traps.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.4Triggerread-writecurrent
irtTrapsAllOff
OBJECT-TYPE
This switches all IRT-traps off - no traps are sent out. In detail, this means in the IRT-MIBs under branches *EventEnable all OIDs are set to 2. Note: This is typically set when using only R&S-MIBs and you don't need IRT-MIBs.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.5Triggerread-writecurrent
rsTrapsAllOn
OBJECT-TYPE
This switches all R&S-traps on - traps for all events (info, warning, fault) are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all OIDs are set to 1. Caution! Enabling all traps is not recommended! Caution! Setting this value influences remote controlling of devices! Too many alarms may flood your network. Use this only for testing - for operation, we suggest switch on only a few important traps. Caution! This enables absolutely all R&S alarms! Make sure you can handle it (network speed, routers, firewalls, NOC database performance etc.).
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.6Triggerread-writecurrent
rsTrapsAllOff
OBJECT-TYPE
This switches all R&S-traps off - no traps are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all OIDs are set to 2. Note: This is typically set when using only IRT-MIBs and you don't need R&S-MIBs.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.7Triggerread-writecurrent
rsTrapsAllFaultsOn
OBJECT-TYPE
This switches all R&S-traps for faults on - traps for all 'faults' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'fault'-OIDs are set to '1'. These traps include the value 'fault(1)' in binding 'eventAlarmClass'. Note: This is the recommended setting when using R&S-MIBs. It gives you an overview of the device state.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.8Triggerread-writecurrent
rsTrapsAllFaultsOff
OBJECT-TYPE
This switches all R&S-traps for faults off - no traps for 'faults' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'fault'-OIDs are set to '2'. These traps include the value 'fault(1)' in binding 'eventAlarmClass'.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.9Triggerread-writecurrent
rsTrapsAllWarningsOn
OBJECT-TYPE
This switches all R&S-traps for warnings on - traps for all 'warnings' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'warning'-OIDs are set to '1'. These traps include the value 'warning(2)' in binding 'eventAlarmClass'. Note: This is the recommended setting when using R&S-MIBs and you want much more informations from the device than only faults. Caution! This enables lots of alarms. Make sure you can handle it (network speed, NOC database performance etc.)...
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.10Triggerread-writecurrent
rsTrapsAllWarningsOff
OBJECT-TYPE
This switches all R&S-traps for warnings off - no traps for 'warnings' are sent out. In detail, this means in the R&S-MIBs under *Events - Events*Table in column event*Mask all 'warning'-OIDs are set to '2'. These traps include the value 'warning(2)' in binding 'eventAlarmClass'.
1.3.6.1.4.1.2566.127.1.2.167.1.1.2.11Triggerread-writecurrent
transmitterConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.3
dateTime
OBJECT-TYPE
The date and time for the transmitter. Notes: Deci-seconds different from 0 are ignored. The range of distance from UTC is -12h..+14h. Omitting the optional UTC fields in a set-request results in keeping the old UTC offset values.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.1DateAndTimeread-writecurrent
ntp
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2
ntpMode
OBJECT-TYPE
Configures the working mode of the NTP client. disabled: no ntp synchronisation will be done step: the time will synchronized every NTP sync-time unknown: NTP mode is currently not determinable. This value must not be written.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.1INTEGER {unknown(1), disabled(2), stepAdjust(4)}read-writecurrent
ntpSyncTimeInterval
OBJECT-TYPE
Set the intervall, how often the NTP client will be synchronized to the NTP server. Note: this is useful in step mode only .
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.2Integer32 (6..1440)read-writecurrent
ntpServerAddrTable
OBJECT-TYPE
Table with server adresses. Currently maximal one entry is allowed.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3not-accessiblecurrent
ntpServerAddrEntry
OBJECT-TYPE
An entry for a ntpServerAddrTable.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1not-accessiblecurrent
ntpServerAddrIdx
OBJECT-TYPE
index for table entry.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.1Integer32 (1)not-accessiblecurrent
ntpServerAddress
OBJECT-TYPE
host name or IP address of server.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.2ReadableStringread-writecurrent
ntpState
OBJECT-TYPE
Shows the actual state of the NTP synchronisation.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.4INTEGER {unknown(1), disabled(2), enabled(3), notRunning(4), syncFailed(5), synchronizing(6), syncOk(7)}read-onlycurrent
ntpLastSync
OBJECT-TYPE
The date/time of the last successful synchronisation.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.5DateAndTimeread-onlycurrent
swMaintenance
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5
restart
OBJECT-TYPE
Restart the software of transmitter's control unit.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.1Triggerread-writecurrent
swUpdate
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5
swUpdateStart
OBJECT-TYPE
Start software update tool at transmitter side in manual mode. The PC tool can only connect to transmitter's control unit if the software update tool on the transmitter is started.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.2Triggerread-writecurrent
swUpdateMode
OBJECT-TYPE
Run mode of the software update tool at the transmitter side. manual: Software update can be started with the Start button. It will stop automaticly after an idle period of 90 seconds. permanent: Software update is always running and will never stop.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.3INTEGER {manual(1), permanent(2)}read-writecurrent
swUpdateDeviceName
OBJECT-TYPE
The Device Name is dedicated to this control unit. It will be shown in the software update tool on the PC to differ devices.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.4ReadableString (SIZE(0..30))read-writecurrent
swUpdateDeviceGroup
OBJECT-TYPE
The Device Group can be used to separate devices in large networks. It must match the Device Group in software update tool on the PC.
1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.5ReadableString (SIZE(0..30))read-writecurrent
rsXx8000CommonEvents
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.2
rsXx8000EventsV2
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.2.0
eventTx
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10
eventsTxV2
OBJECT-IDENTITY
Compatibility to SMIv1.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0current
eventsTxTable
OBJECT-TYPE
This table contains necessary information for handling alarms. For each alarm you have the following information: - name (get), - mask to enable/disable sending out (set/get), - priority (set/get) and - the current state (get only).
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1not-accessiblecurrent
eventsTxEntry
OBJECT-TYPE
An event entry always consists of 3 values: - name: an enumerated list of all possible notifications - mask: the corresponding mask (enable/disable) - priority: the corresponding priority (value in range 0..255) - event: the event itself (active/inactive)
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1not-accessiblecurrent
eventTxNameIdx
OBJECT-TYPE
The event number as integer. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.1EventMaxEntryNumbernot-accessiblecurrent
eventTxName
OBJECT-TYPE
The event number as integer and the value as readable text. The enumeration correlates with the notifications under eventsTxV2.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.2INTEGER {swUpdateStarted(1), ntpSyncFailed(2)}read-onlycurrent
eventTxMask
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.3EventMaskread-writecurrent
eventTxPriority
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.4EventPriorityread-writecurrent
eventTxEvent
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.5EventStateread-onlycurrent
eventHistory
OBJECT-IDENTITY
Information about sent out events.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1current
counterEvents
OBJECT-TYPE
The total number of traps sent out. This is an increasing value.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.1Counter32read-onlycurrent
eventHistoryTable
OBJECT-TYPE
The table of the last 100 messages sent out.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2not-accessiblecurrent
eventHistoryEntry
OBJECT-TYPE
An event entry.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1not-accessiblecurrent
eventHistoryNumber
OBJECT-TYPE
The trap number.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.1Integer32 (1..2147483647)not-accessiblecurrent
eventHistoryModule
OBJECT-TYPE
This column indicates the physical module the corresponding message is for.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.2INTEGER {switchoverUnit(1), netccu(2), exciterA(3), exciterB(4), outputstageA(5), outputstageB(6), dvbReceiver(7), pumpA(8), pumpB(9), antenna(10), gps(11), dvbRecMon(12), gpParIO(13), program(14)}read-onlycurrent
eventHistoryEvent
OBJECT-TYPE
This column indicates the event. In correlation with column eventHistoryModule, you can see the name of the event here. For this, you need to have a look at the event definitions of the corresponding MIB. Example: For a DVB transmitter an entry in eventHistoryModule is netccu(2) and the value in eventHistoryEvent is 1. A look at eventsTxV2 of RS-XX8000-DVB-TX-MIB shows, 1 is txSummaryFault.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.3Integer32read-onlycurrent
eventHistoryEventState
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.4EventStateread-onlycurrent
eventHistoryEventDate
OBJECT-TYPE
This column indicates the date and time of the event.
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.5DateAndTimeread-onlycurrent
eventHistoryTx
OBJECT-TYPE
The transmitter index in case of NTx or Np1 systems. For variants with one transmitter only (SingleTx) this index is always transmitterB(1).
1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.101IndexTransmitterread-onlycurrent
eventMapObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.2.3
eventAlarmPriority
OBJECT-TYPE
This OID holds the value for the priority when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.1EventPriorityaccessible-for-notifycurrent
eventAlarmClass
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.2EventClassaccessible-for-notifycurrent
eventEvent
OBJECT-TYPE
This OID holds the value for the event itself when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.3EventStateaccessible-for-notifycurrent
indexTransmitter
OBJECT-TYPE
This OID holds the value for the transmitter when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.4IndexTransmitteraccessible-for-notifycurrent
indexAB
OBJECT-TYPE
This OID holds the value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.5IndexABaccessible-for-notifycurrent
indexRack
OBJECT-TYPE
This OID holds the value for the rack when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.6IndexRackaccessible-for-notifycurrent
indexAmplifier
OBJECT-TYPE
This OID holds the value for the amplifier when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.7IndexAmplifieraccessible-for-notifycurrent
indexProgram
OBJECT-TYPE
This object holds the value for the program when sending out a notification.
1.3.6.1.4.1.2566.127.1.2.167.1.2.3.8IndexProgramaccessible-for-notifycurrent
rsXx8000CommonConf
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.3
rsXx8000CommonGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.3.1
rsXx8000CommonCompls
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.167.1.3.2

Notifications

NameOIDStatus
testTrap
NOTIFICATION-TYPE
This trap is sent to check whether the trapsink is receiving any traps from this agent. To trigger this trap, set 'sendTestTrap' to '2'.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.1current
swUpdateStarted
NOTIFICATION-TYPE
Software update started. The PC tool can only connect to transmitter's control unit if the software update tool on the transmitter is started. It uses the network 17 (TCP and UDP).
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.1current
ntpSyncFailed
NOTIFICATION-TYPE
NTP synchronisation failed.
1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.2current

Conformance

NameOIDStatus
groupNotifyTest
NOTIFICATION-GROUP
test notifications.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.1current
groupNotify
NOTIFICATION-GROUP
notifications for all transmitters.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.2current
groupEventTest
OBJECT-GROUP
The objects sent with testTrap.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.6current
groupEventHistory
OBJECT-GROUP
Contains all objects from 'eventHistory'.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.8current
groupEventObjects
OBJECT-GROUP
Contains all objects from 'eventMapObjects'.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.9current
groupProductInformation
OBJECT-GROUP
Contains all objects from 'productInformation' (R&S typeplate).
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.11current
groupSnmpConfig
OBJECT-GROUP
Contains all objects from 'snmpConfig'.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.12current
groupTransmitterConfig
OBJECT-GROUP
objects from 'transmitterConfig'.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.13current
groupNTP
OBJECT-GROUP
objects from 'ntp'
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.14current
groupSwMaintenance
OBJECT-GROUP
objects from 'swMaintenance'
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.15current
groupNotifyNTP
NOTIFICATION-GROUP
Notifications from the NTP client.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.16current
groupObsoletedObjects
OBJECT-GROUP
Description.
1.3.6.1.4.1.2566.127.1.2.167.1.3.1.17obsolete
xx8000BasicCompliance
MODULE-COMPLIANCE
The compliance statement for XX8000 entities which implement this MIB module.
1.3.6.1.4.1.2566.127.1.2.167.1.3.2.1current