MIBs Depot

PW-STD-MIB

Registered at
1.3.6.1.2.1.10.246
Last updated
2009-06-11 00:00
Organization
Pseudowire Edge-to-Edge Emulation (PWE3) Working Group
Revisions
2009-06-11 00:00
Namespace
standard
Source file
PW-STD-MIB
Digest
sha256:8c22e5d21870eb1c4481b859bb3d88dc16df146401699d4fc940a8d6851bb8cc

Description

This MIB module contains managed object definitions for pseudowire operation as in Bryant, S. and P. Pate, 'Pseudo Wire Emulation Edge-to-Edge (PWE3) Architecture' [RFC3985], Martini, L., et al, 'Pseudowire Setup and Maintenance Using the Label Distribution Protocol (LDP)' [RFC4447], and Townsley, M., et al, 'Layer Two Tunneling Protocol (Version 3)' [RFC3931]. This MIB module enables the use of any underlying packet switched network (PSN). MIB nodules that will support PW operations over specific PSN types are defined in separate memos. The indexes for this MIB module are also used to index the PSN-specific tables and the PW-specific tables. The PW Type dictates which PW-specific MIB module to use. Copyright (c) 2009 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: - Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. - Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. - Neither the name of Internet Society, IETF or IETF Trust, nor the names of specific contributors, may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. This version of this MIB module is part of RFC 5601; see the RFC itself for full legal notices.

Contact

David Zelig Email: davidz@oversi.com Thomas D. Nadeau Email: tom.nadeau@bt.com The PWE3 Working Group (email distribution pwe3@ietf.org, http://www.ietf.org/html.charters/pwe3-charter.html)

Imports

FromSymbols
HC-PerfHist-TC-MIBHCPerfCurrentCount, HCPerfIntervalCount, HCPerfTimeElapsed, HCPerfValidIntervals
IANA-PWE3-MIBIANAPwCapabilities, IANAPwPsnTypeTC, IANAPwTypeTC
IF-MIBInterfaceIndexOrZero
INET-ADDRESS-MIBInetAddress, InetAddressType
PW-TC-STD-MIBPwAttachmentIdentifierType, PwCwStatusTC, PwFragSize, PwFragStatus, PwGenIdType, PwGroupID, PwIDType, PwIndexOrZeroType, PwIndexType, PwOperStatusTC, PwStatus
PerfHist-TC-MIBPerfCurrentCount, PerfIntervalCount
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, transmission
SNMPv2-TCDisplayString, RowStatus, StorageType, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HC-PerfHist-TC-MIB
IANA-PWE3-MIB
IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
PW-STD-MIB
PW-TC-STD-MIB
PerfHist-TC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
pwNotifications
OBJECT-IDENTITY
1.3.6.1.2.1.10.246.0
pwObjects
OBJECT-IDENTITY
1.3.6.1.2.1.10.246.1
pwIndexNext
OBJECT-TYPE
This object contains an appropriate value to be used for pwIndex when creating entries in the pwTable. The value 0 indicates that no unassigned entries are available. To obtain the value of pwIndex for a new entry in the pwTable, the manager issues a management protocol retrieval operation. The agent will determine through its local policy when this index value will be made available for reuse.
1.3.6.1.2.1.10.246.1.1Unsigned32read-onlycurrent
pwTable
OBJECT-TYPE
This table specifies information for configuring and status monitoring that is common to all service types and PSN types.
1.3.6.1.2.1.10.246.1.2not-accessiblecurrent
pwEntry
OBJECT-TYPE
A row in this table represents a pseudowire (PW) virtual connection across a packet network. It is indexed by pwIndex, which uniquely identifies a singular connection. A row can be created by an operator command from a management plan of a PE, by signaling, or due to auto- discovery process. An operator's command can be issued via a non-SNMP application; in such case, a row will be created implicitly by the agent. The read-create objects in this table are divided into three categories: 1) Objects that MUST NOT be changed after row activation. These are objects that define basic properties of the PW (for example type, destination, etc.). 2) Objects that MAY be changed when the PW is defined as not active. A change of these objects involves re-signaling of the PW or it might be traffic affecting. PW not active is defined as one of the following conditions: a) The pwRowStatus is notInService(2). b) The pwRowStatus is notReady(3). c) The pwAdminStatus is down(2). If the operator needs to change one of the values for an active row, the operator can either set the pwRowStatus to notInService(2) or set pwAdminStatus to down(2). Signaling (or traffic) is initiated again upon setting the pwRowStatus to active(1) or setting the pwAdminStatus to up(1) or testing(3), respectively. 3) Objects that MAY be changed at any time. A PW MAY have an entry in the ifTable in addition to the entry in this table. In this case, a special ifType for PW will be set in the ifTable, and the ifIndex in the ifTable of the PW will be set in the pwIfIndex object in this table. By default, all the read-create objects MUST NOT be changed after row activation, unless specifically indicated in the individual object description. Manual entries in this table SHOULD be preserved after a reboot; the agent MUST ensure the integrity of those entries. If the set of entries of a specific row are found to be inconsistent after reboot, the PW pwOperStatus MUST be declared as notPresent(5).
1.3.6.1.2.1.10.246.1.2.1not-accessiblecurrent
pwIndex
OBJECT-TYPE
A unique index for the conceptual row identifying a PW within this table.
1.3.6.1.2.1.10.246.1.2.1.1PwIndexTypenot-accessiblecurrent
pwType
OBJECT-TYPE
This value indicates the emulated service to be carried over this PW.
1.3.6.1.2.1.10.246.1.2.1.2IANAPwTypeTCread-createcurrent
pwOwner
OBJECT-TYPE
This object is set by the operator to indicate the protocol responsible for establishing this PW. 'manual' is used in all cases where no maintenance protocol (PW signaling) is used to set up the PW, i.e., configuration of entries in the PW tables including PW labels, etc., is done by setting the MIB fields manually. 'pwIdFecSignaling' is used in case of signaling with the Pwid FEC element with LDP signaling. 'genFecSignaling' is used in case of LDP signaling with the generalized FEC. 'l2tpControlProtocol' indicates the use of the L2TP control protocol. 'other' is used for other types of signaling.
1.3.6.1.2.1.10.246.1.2.1.3INTEGER {manual(1), pwIdFecSignaling(2), genFecSignaling(3), l2tpControlProtocol(4), other(5)}read-createcurrent
pwPsnType
OBJECT-TYPE
This object is set by the operator to indicate the PSN type. Based on this object, the relevant PSN table's entry is created in the PSN-specific MIB modules.
1.3.6.1.2.1.10.246.1.2.1.4IANAPwPsnTypeTCread-createcurrent
pwSetUpPriority
OBJECT-TYPE
This object defines the relative priority of the PW during set-up in a lowest-to-highest fashion, where 0 is the highest priority. PWs with the same priority are treated with equal priority. PWs that have not yet completed setup will report 'dormant' in the pwOperStatus. This value is significant if there are competing resources among PWs and the implementation supports this feature. Equal priority handling with competing resources is implementation specific. This object MAY be changed at any time.
1.3.6.1.2.1.10.246.1.2.1.5Integer32 (0..7)read-createcurrent
pwHoldingPriority
OBJECT-TYPE
This object defines the relative holding priority of the PW in a lowest-to-highest fashion, where 0 is the highest priority. PWs with the same priority are treated equally. This value is significant if there are competing resources among PWs and the implementation supports this feature. Equal priority handling with competing resources is implementation specific. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.6Integer32 (0..7)read-createcurrent
pwPeerAddrType
OBJECT-TYPE
Denotes the address type of the peer node. It should be set to 'unknown' if PE/PW maintenance protocol is not used and the address is unknown.
1.3.6.1.2.1.10.246.1.2.1.8InetAddressTyperead-createcurrent
pwPeerAddr
OBJECT-TYPE
This object contains the value of the peer node address of the PW/PE maintenance protocol entity. This object SHOULD contain a value of all zeroes if not applicable (pwPeerAddrType is 'unknown').
1.3.6.1.2.1.10.246.1.2.1.9InetAddressread-createcurrent
pwAttachedPwIndex
OBJECT-TYPE
If the PW is attached to another PW instead of a local native service, this item indicates the pwIndex of the attached PW. Otherwise, this object MUST be set to zero. Attachment to another PW will have no PW specific entry in any of the service MIB modules.
1.3.6.1.2.1.10.246.1.2.1.10PwIndexOrZeroTyperead-createcurrent
pwIfIndex
OBJECT-TYPE
This object indicates the ifIndex of the PW if the PW is represented in the ifTable. Otherwise, it MUST be set to zero.
1.3.6.1.2.1.10.246.1.2.1.11InterfaceIndexOrZeroread-createcurrent
pwID
OBJECT-TYPE
Pseudowire identifier. If the pwOwner object is 'pwIdFecSignaling' or 'l2tpControlProtocol', then this object is signaled in the outgoing PW ID field within the 'Virtual Circuit FEC Element'. For other values of pwOwner, this object is not signaled and it MAY be set to zero. For implementations that support the pwIndexMappingTable, a non-zero value is RECOMMENDED, even if this identifier is not signaled. This is so that reverse mappings can be provided by pwIndexMappingTable and pwPeerMappingTable. It is therefore RECOMMENDED that the value of this pwID be unique (or if pwPeerAddrType is not 'unknown', at least [pwType, pwID, pwPeerAddrType, pwPeerAddr] is unique.)
1.3.6.1.2.1.10.246.1.2.1.12PwIDTyperead-createcurrent
pwLocalGroupID
OBJECT-TYPE
Used in the Group ID field sent to the peer PW End Service within the maintenance protocol used for PW setup. It SHOULD be set to zero if a maintenance protocol is not used.
1.3.6.1.2.1.10.246.1.2.1.13PwGroupIDread-createcurrent
pwGroupAttachmentID
OBJECT-TYPE
This object is an octet string representing the attachment group identifier (AGI) that this PW belongs to, which typically identifies the VPN ID. Applicable if pwOwner equals 'genFecSignaling'.
1.3.6.1.2.1.10.246.1.2.1.14PwAttachmentIdentifierTyperead-createcurrent
pwLocalAttachmentID
OBJECT-TYPE
This object is an octet string representing the local forwarder attachment individual identifier (AII) to be used by this PW. It is used as the Source AII (SAII) for outgoing signaling messages and the Target AII (TAII) in the incoming messages from the peer. Applicable if pwOwner equal 'genFecSignaling'.
1.3.6.1.2.1.10.246.1.2.1.15PwAttachmentIdentifierTyperead-createcurrent
pwRemoteAttachmentID
OBJECT-TYPE
This object is an octet string representing the remote forwarder attachment individual identifier (AII) to be used by this PW. It is used as the TAII for outgoing signaling messages and the SAII in the incoming messages from the peer. Applicable if pwOwner equals 'genFecSignaling'.
1.3.6.1.2.1.10.246.1.2.1.16PwAttachmentIdentifierTyperead-createcurrent
pwCwPreference
OBJECT-TYPE
Defines if the control word will be sent with each packet by the local node. Some PW types mandate the use of a control word, and in such cases, the value configured for this object has no effect on the existence of the control word. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.17TruthValueread-createcurrent
pwLocalIfMtu
OBJECT-TYPE
If not equal to zero, the optional IfMtu object in the signaling protocol will be sent with this value, which represents the locally supported MTU size over the interface (or the virtual interface) associated with the PW. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.18Unsigned32 (0..65535)read-createcurrent
pwLocalIfString
OBJECT-TYPE
A PW MAY be associated to an interface (or a virtual interface) in the ifTable of the node as part of the service configuration. This object defines if the maintenance protocol will send the interface's name (ifAlias) as it appears in the ifTable. If set to false, the optional element will not be sent. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.19TruthValueread-createcurrent
pwLocalCapabAdvert
OBJECT-TYPE
If a maintenance protocol is used, it indicates the capabilities the local node will advertise to the peer. The operator MAY selectively assign a partial set of capabilities. In case of manual configuration of the PW, the operator SHOULD set non-conflicting options (for example, only a single type of Operations, Administration, and Management (OAM)) out of the available options in the implementation. It is possible to change the value of this object when the PW is not active. The agent MUST reject any attempt to set a capability that is not supported. The default value MUST be the full set of local node capabilities.
1.3.6.1.2.1.10.246.1.2.1.20IANAPwCapabilitiesread-createcurrent
pwRemoteGroupID
OBJECT-TYPE
This object is obtained from the Group ID field as received via the maintenance protocol used for PW setup. Value of zero will be reported if not used. Value of 0xFFFFFFFF shall be used if the object is yet to be defined by the PW maintenance protocol.
1.3.6.1.2.1.10.246.1.2.1.21PwGroupIDread-onlycurrent
pwCwStatus
OBJECT-TYPE
If signaling is used for PW establishment, this object indicates the status of the control word negotiation. For either signaling or manual configuration, it indicates if the control word (CW) is to be present for this PW.
1.3.6.1.2.1.10.246.1.2.1.22PwCwStatusTCread-onlycurrent
pwRemoteIfMtu
OBJECT-TYPE
The remote interface MTU as (optionally) received from the remote node via the maintenance protocol. The object SHOULD report zero if the MTU is not available.
1.3.6.1.2.1.10.246.1.2.1.23Unsigned32read-onlycurrent
pwRemoteIfString
OBJECT-TYPE
Indicates the interface description string as received by the maintenance protocol. It MUST be a NULL string if a maintenance protocol is not used or the value is not known yet.
1.3.6.1.2.1.10.246.1.2.1.24SnmpAdminString (SIZE(0..80))read-onlycurrent
pwRemoteCapabilities
OBJECT-TYPE
Indicates the capabilities as received from the peer.
1.3.6.1.2.1.10.246.1.2.1.25IANAPwCapabilitiesread-onlycurrent
pwFragmentCfgSize
OBJECT-TYPE
If set to a value other than zero, indicates that fragmentation is desired for this PW. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.26PwFragSizeread-createcurrent
pwRmtFragCapability
OBJECT-TYPE
The status of the fragmentation based on the local configuration and the peer capabilities as received from the peer when a control protocol is used.
1.3.6.1.2.1.10.246.1.2.1.27PwFragStatusread-onlycurrent
pwFcsRetentionCfg
OBJECT-TYPE
The local configuration of Frame Check Sequence (FCS) retention for this PW. FCS retention can be configured for PW types High-Level Data Link Control (HDLC), Point-to-Point Protocol (PPP), and Ethernet only. If the implementation does not support FCS retention, an error MUST be reported in pwFcsRetentionStatus. This object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.28INTEGER {fcsRetentionDisable(1), fcsRetentionEnable(2)}read-createcurrent
pwFcsRetentionStatus
OBJECT-TYPE
The status of the FCS retention negotiation process based on local configuration and the remote advertisement. remoteIndicationUnknown - set if a FEC has not been received from the remote. remoteRequestFcsRetention - indicates that the peer has requested FCS retention. FCS retention will be used if the local node is capable and configured to use it for this PW. fcsRetentionEnabled - FCS retention is enabled (both peers were configured for FCS retention for signaled PW, or the local node is configured and capable of FCS retention for manually assigned PWs). fcsRetentionDisabled - FCS retention is disabled (not configured locally or not advertised by the peer). localFcsRetentionCfgErr - set if the local node has been configured for FCS retention but is not capable to support it. fcsRetentionFcsSizeMismatch - set if there is an FCS size mismatch between the local and the peer node.
1.3.6.1.2.1.10.246.1.2.1.29Bits {remoteIndicationUnknown(0), remoteRequestFcsRetention(1), fcsRetentionEnabled(2), fcsRetentionDisabled(3), localFcsRetentionCfgErr(4), fcsRetentionFcsSizeMismatch(5)}read-onlycurrent
pwOutboundLabel
OBJECT-TYPE
The PW label used in the outbound direction (i.e., toward the PSN). It might be set manually if pwOwner is 'manual'; otherwise, it is set automatically. For MPLS, MPLS over IP, or MPLS over Generic Routing Encapsulation (GRE) PSN, it represents the 20-bit PW tag; for L2TP, it represents the 32-bit Session ID; and for IP PSN, it represents the destination UDP port number. If the label is not yet known (signaling in process), the object SHOULD return a value of 0xFFFFFFFF. For manual configuration, this object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.30Unsigned32read-createcurrent
pwInboundLabel
OBJECT-TYPE
The PW label used in the inbound direction (i.e., packets received from the PSN). It may be set manually if pwOwner is 'manual'; otherwise, it is set automatically. For MPLS, MPLS over IP, or MPLS over GRE PSN, it represents the 20-bit PW tag; for L2TP, it represents the 32-bit Session ID; and for IP PSN, it represents the source UDP port number. If the label is not yet known (signaling in process), the object SHOULD return a value of 0xFFFFFFFF. For manual configuration, this object MAY be changed only if the PW is not active.
1.3.6.1.2.1.10.246.1.2.1.31Unsigned32read-createcurrent
pwName
OBJECT-TYPE
The canonical name assigned to the PW. This object MAY be changed at any time.
1.3.6.1.2.1.10.246.1.2.1.32SnmpAdminStringread-createcurrent
pwDescr
OBJECT-TYPE
A textual string containing information about the PW. If there is no description, this object contains a zero- length string. This object MAY be changed at any time.
1.3.6.1.2.1.10.246.1.2.1.33SnmpAdminStringread-createcurrent
pwCreateTime
OBJECT-TYPE
The value of sysUpTime at the time this PW was created.
1.3.6.1.2.1.10.246.1.2.1.34TimeStampread-onlycurrent
pwUpTime
OBJECT-TYPE
Specifies the time since last change of pwOperStatus to Up(1).
1.3.6.1.2.1.10.246.1.2.1.35TimeTicksread-onlycurrent
pwLastChange
OBJECT-TYPE
The value of sysUpTime at the time the PW entered its current operational state. If the current state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.2.1.10.246.1.2.1.36TimeTicksread-onlycurrent
pwAdminStatus
OBJECT-TYPE
The desired operational status of this PW. This object MAY be set at any time.
1.3.6.1.2.1.10.246.1.2.1.37INTEGER {up(1), down(2), testing(3)}read-createcurrent
pwOperStatus
OBJECT-TYPE
This object indicates the operational status of the PW; it does not reflect the status of the Customer Edge (CE) bound interface. It is set to down only if pwNotForwarding, psnFacingPwRxFault, or psnFacingPwTxFault indications are set in pwLocalStatus or pwRemoteStatus. It indicates 'lowerLayerDown' if the only reason for not being in the 'up' state is that either the outer tunnel or physical layer of the network side is in the 'down' state. All other states are declared based on the description of the PwOperStatusTC.
1.3.6.1.2.1.10.246.1.2.1.38PwOperStatusTCread-onlycurrent
pwLocalStatus
OBJECT-TYPE
Indicates the status of the PW in the local node. The various indications in this object SHOULD be available independent of the ability of the local node to advertise them or the remote node to accept these status indications through the control protocol.
1.3.6.1.2.1.10.246.1.2.1.39PwStatusread-onlycurrent
pwRemoteStatusCapable
OBJECT-TYPE
Indicates the remote node capability to advertise the PW status notification. notApplicable SHOULD be reported for a manually set PW, or if the local node is not capable of accepting the status notification object. notYetKnown SHOULD be reported if the signaling protocol has not yet finished the process of capability determination. remoteCapable and remoteNotcapable SHOULD be reported based on the initial signaling exchange that has determined the remote node capability.
1.3.6.1.2.1.10.246.1.2.1.40INTEGER {notApplicable(1), notYetKnown(2), remoteCapable(3), remoteNotCapable(4)}read-onlycurrent
pwRemoteStatus
OBJECT-TYPE
Indicates the status of the PW as was advertised by the remote. If the remote is not capable of advertising the status object, or the local node is not able to accept the status object through signaling, then the applicable bit is 'pwNotForwarding', which is set if the remote has sent label release or label withdraw for this PW.
1.3.6.1.2.1.10.246.1.2.1.41PwStatusread-onlycurrent
pwTimeElapsed
OBJECT-TYPE
The number of seconds, including partial seconds, that have elapsed since the beginning of the current interval measurement period.
1.3.6.1.2.1.10.246.1.2.1.42HCPerfTimeElapsedread-onlycurrent
pwValidIntervals
OBJECT-TYPE
The number of previous 15-minute intervals for which data was collected.
1.3.6.1.2.1.10.246.1.2.1.43HCPerfValidIntervalsread-onlycurrent
pwRowStatus
OBJECT-TYPE
For creating, modifying, and deleting this row. This object MAY be changed at any time.
1.3.6.1.2.1.10.246.1.2.1.44RowStatusread-createcurrent
pwStorageType
OBJECT-TYPE
This variable indicates the storage type for this object.
1.3.6.1.2.1.10.246.1.2.1.45StorageTyperead-createcurrent
pwOamEnable
OBJECT-TYPE
This variable indicates if OAM is enabled for this PW. It MAY be changed at any time.
1.3.6.1.2.1.10.246.1.2.1.46TruthValueread-createcurrent
pwGenAGIType
OBJECT-TYPE
This variable indicates the AGI type if generalized FEC (129) is used for PW signaling or configuration. It SHOULD return the value of zero otherwise.
1.3.6.1.2.1.10.246.1.2.1.47PwGenIdTyperead-createcurrent
pwGenLocalAIIType
OBJECT-TYPE
This object is the type of the local forwarder attachment individual identifier (AII) to be used by this PW if generalized FEC (129) is used for PW signaling or configuration.
1.3.6.1.2.1.10.246.1.2.1.48PwGenIdTyperead-createcurrent
pwGenRemoteAIIType
OBJECT-TYPE
This object is the type of the remote forwarder attachment individual identifier (AII) to be used by this PW if generalized FEC (129) is used for PW signaling or configuration.
1.3.6.1.2.1.10.246.1.2.1.49PwGenIdTyperead-createcurrent
pwPerfCurrentTable
OBJECT-TYPE
This table provides per-PW performance information for the current interval.
1.3.6.1.2.1.10.246.1.3not-accessiblecurrent
pwPerfCurrentEntry
OBJECT-TYPE
An entry in this table is created by the agent for every PW.
1.3.6.1.2.1.10.246.1.3.1not-accessiblecurrent
pwPerfCurrentInHCPackets
OBJECT-TYPE
High-capacity counter for number of packets received by the PW (from the PSN) in the current 15-minute interval. This is the 64-bit version of pwPerfCurrentInPackets, if pwPerfCurrentInHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.1HCPerfCurrentCountread-onlycurrent
pwPerfCurrentInHCBytes
OBJECT-TYPE
High-capacity counter for number of bytes received by the PW (from the PSN) in the current 15-minute interval. This is the 64-bit version of pwPerfCurrentInBytes, if pwPerfCurrentInHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.2HCPerfCurrentCountread-onlycurrent
pwPerfCurrentOutHCPackets
OBJECT-TYPE
High-capacity counter for number of packets forwarded by the PW (to the PSN) in the current 15-minute interval. This is the 64-bit version of pwPerfCurrentOutPackets, if pwPerfCurrentOutHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.3HCPerfCurrentCountread-onlycurrent
pwPerfCurrentOutHCBytes
OBJECT-TYPE
High-capacity counter for number of bytes forwarded by the PW (to the PSN) in the current 15-minute interval. This is the 64-bit version of pwPerfCurrentOutBytes, if pwPerfCurrentOutHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.4HCPerfCurrentCountread-onlycurrent
pwPerfCurrentInPackets
OBJECT-TYPE
The counter for number of packets received by the PW (from the PSN) in the current 15-minute interval. This is the 32-bit version of pwPerfCurrentInHCPackets, if pwPerfCurrentInHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.5PerfCurrentCountread-onlycurrent
pwPerfCurrentInBytes
OBJECT-TYPE
The counter for number of bytes received by the PW (from the PSN) in the current 15-minute interval. It MUST be equal to the least significant 32 bits of pwPerfCurrentInHCBytes, if pwPerfCurrentInHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.6PerfCurrentCountread-onlycurrent
pwPerfCurrentOutPackets
OBJECT-TYPE
The counter for number of packets forwarded by the PW (to the PSN) in the current 15-minute interval. It MUST be equal to the least significant 32 bits of pwPerfCurrentOutHCPackets, if pwPerfCurrentOutHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.7PerfCurrentCountread-onlycurrent
pwPerfCurrentOutBytes
OBJECT-TYPE
The counter for number of bytes forwarded by the PW (to the PSN) in the current 15-minute interval. It MUST be equal to the least significant 32 bits of pwPerfCurrentOutHCBytes, if pwPerfCurrentOutHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.3.1.8PerfCurrentCountread-onlycurrent
pwPerfIntervalTable
OBJECT-TYPE
This table provides per-PW performance information for each interval.
1.3.6.1.2.1.10.246.1.4not-accessiblecurrent
pwPerfIntervalEntry
OBJECT-TYPE
An entry in this table is created by the agent for every PW.
1.3.6.1.2.1.10.246.1.4.1not-accessiblecurrent
pwPerfIntervalNumber
OBJECT-TYPE
A number N, between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15-minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. The minimum range of N is 1 through 4. The default range is 1 to 32. The maximum range of N is 1 through 96.
1.3.6.1.2.1.10.246.1.4.1.1Integer32 (1..96)not-accessiblecurrent
pwPerfIntervalValidData
OBJECT-TYPE
This variable indicates if the data for this interval is valid.
1.3.6.1.2.1.10.246.1.4.1.2TruthValueread-onlycurrent
pwPerfIntervalTimeElapsed
OBJECT-TYPE
The duration of this interval in seconds.
1.3.6.1.2.1.10.246.1.4.1.3HCPerfTimeElapsedread-onlycurrent
pwPerfIntervalInHCPackets
OBJECT-TYPE
High-capacity counter for number of packets received by the PW (from the PSN) during the interval. This is the 64-bit version of pwPerfIntervalInPackets, if pwPerfIntervalInHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.4HCPerfIntervalCountread-onlycurrent
pwPerfIntervalInHCBytes
OBJECT-TYPE
High-capacity counter for number of bytes received by the PW (from the PSN) during the interval. This is the 64-bit version of pwPerfIntervalInBytes, if pwPerfIntervalInHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.5HCPerfIntervalCountread-onlycurrent
pwPerfIntervalOutHCPackets
OBJECT-TYPE
High-capacity counter for number of packets forwarded by the PW (to the PSN) during the interval. This is the 64-bit version of pwPerfIntervalOutPackets, if pwPerfIntervalOutHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.6HCPerfIntervalCountread-onlycurrent
pwPerfIntervalOutHCBytes
OBJECT-TYPE
High-capacity counter for number of bytes forwarded by the PW (to the PSN) during the interval. This is the 64-bit version of pwPerfIntervalOutBytes, if pwPerfIntervalOutHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.7HCPerfIntervalCountread-onlycurrent
pwPerfIntervalInPackets
OBJECT-TYPE
This value represents the number of packets received by this PW during the interval. It MUST be equal to the least significant 32 bits of pwPerfIntervalInHCPackets, if pwPerfIntervalInHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.8PerfIntervalCountread-onlycurrent
pwPerfIntervalInBytes
OBJECT-TYPE
This value represents the number of bytes received by this PW during the interval. It MUST be equal to the least significant 32 bits of pwPerfIntervalInHCBytes, if pwPerfIntervalInHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.9PerfIntervalCountread-onlycurrent
pwPerfIntervalOutPackets
OBJECT-TYPE
This value represents the number of packets sent by this PW during the interval. It MUST be equal to the least significant 32 bits of pwPerfIntervalOutHCPackets, if pwPerfIntervalOutHCPackets is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.10PerfIntervalCountread-onlycurrent
pwPerfIntervalOutBytes
OBJECT-TYPE
This value represents the number of bytes sent by this PW during the interval. It MUST be equal to the least significant 32 bits of pwPerfIntervalOutHCBytes, if pwPerfIntervalOutHCBytes is supported according to the rules spelled out in RFC 2863.
1.3.6.1.2.1.10.246.1.4.1.11PerfIntervalCountread-onlycurrent
pwPerf1DayIntervalTable
OBJECT-TYPE
This table provides per-PW performance information for the current day's measurement and the previous day's interval.
1.3.6.1.2.1.10.246.1.5not-accessiblecurrent
pwPerf1DayIntervalEntry
OBJECT-TYPE
An entry in this table is created by the agent for every PW.
1.3.6.1.2.1.10.246.1.5.1not-accessiblecurrent
pwPerf1DayIntervalNumber
OBJECT-TYPE
History Data Interval number. Interval 1 is the current day's measurement period, interval 2 is the most recent previous day, and interval 30 is 31 days ago. Intervals 3..31 are optional.
1.3.6.1.2.1.10.246.1.5.1.1Unsigned32 (1..31)not-accessiblecurrent
pwPerf1DayIntervalValidData
OBJECT-TYPE
This variable indicates if the data for this interval is valid.
1.3.6.1.2.1.10.246.1.5.1.2TruthValueread-onlycurrent
pwPerf1DayIntervalTimeElapsed
OBJECT-TYPE
The number of seconds in the 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the interval duration except in a situation where performance monitoring data could not be collected for any reason or where agent clock adjustments have been made.
1.3.6.1.2.1.10.246.1.5.1.3HCPerfTimeElapsedread-onlycurrent
pwPerf1DayIntervalInHCPackets
OBJECT-TYPE
High-capacity counter for the total number of packets received by the PW (from the PSN).
1.3.6.1.2.1.10.246.1.5.1.4Counter64read-onlycurrent
pwPerf1DayIntervalInHCBytes
OBJECT-TYPE
High-capacity counter for the total number of bytes received by the PW (from the PSN).
1.3.6.1.2.1.10.246.1.5.1.5Counter64read-onlycurrent
pwPerf1DayIntervalOutHCPackets
OBJECT-TYPE
High-capacity counter for the total number of packets forwarded by the PW (to the PSN).
1.3.6.1.2.1.10.246.1.5.1.6Counter64read-onlycurrent
pwPerf1DayIntervalOutHCBytes
OBJECT-TYPE
High-capacity counter for the total number of bytes forwarded by the PW (to the PSN).
1.3.6.1.2.1.10.246.1.5.1.7Counter64read-onlycurrent
pwPerfTotalErrorPackets
OBJECT-TYPE
Counter for number of errors at the PW processing level, for example, packets received with unknown PW label.
1.3.6.1.2.1.10.246.1.6Counter32read-onlycurrent
pwIndexMappingTable
OBJECT-TYPE
This table enables the reverse mapping of the unique PWid parameters [peer IP, PW type, and PW ID] and the pwIndex. The table is not applicable for PWs created manually or by using the generalized FEC.
1.3.6.1.2.1.10.246.1.7not-accessiblecurrent
pwIndexMappingEntry
OBJECT-TYPE
An entry in this table MUST be created by the agent for every PW created by the pwTable for which pwOwner equals pwIdFecSignaling and pwID is not zero. Implementers need to be aware that if the value of the pwIndexMappingPeerAddr (an OID) has more than 113 sub-identifiers, then OIDs of column instances in this table will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
1.3.6.1.2.1.10.246.1.7.1not-accessiblecurrent
pwIndexMappingPwType
OBJECT-TYPE
The PW type (indicates the service) of this PW.
1.3.6.1.2.1.10.246.1.7.1.1IANAPwTypeTCnot-accessiblecurrent
pwIndexMappingPwID
OBJECT-TYPE
The PW ID of this PW. Zero if the PW is configured manually.
1.3.6.1.2.1.10.246.1.7.1.2PwIDTypenot-accessiblecurrent
pwIndexMappingPeerAddrType
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.2.1.10.246.1.7.1.3InetAddressTypenot-accessiblecurrent
pwIndexMappingPeerAddr
OBJECT-TYPE
IP address of the peer node.
1.3.6.1.2.1.10.246.1.7.1.4InetAddressnot-accessiblecurrent
pwIndexMappingPwIndex
OBJECT-TYPE
The value that represents the PW in the pwTable.
1.3.6.1.2.1.10.246.1.7.1.5PwIndexTyperead-onlycurrent
pwPeerMappingTable
OBJECT-TYPE
This table provides reverse mapping of the existing PW based on PW type and PW ID ordering. This table is typically useful for the element management system (EMS) ordered query of existing PWs.
1.3.6.1.2.1.10.246.1.8not-accessiblecurrent
pwPeerMappingEntry
OBJECT-TYPE
An entry in this table is created by the agent for every PW entry in the pwTable. Implementers need to be aware that if the value of the pwPeerMappingPeerAddr (an OID) has more than 113 sub-identifiers, then OIDs of column instances in this table will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
1.3.6.1.2.1.10.246.1.8.1not-accessiblecurrent
pwPeerMappingPeerAddrType
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.2.1.10.246.1.8.1.1InetAddressTypenot-accessiblecurrent
pwPeerMappingPeerAddr
OBJECT-TYPE
IP address of the peer node.
1.3.6.1.2.1.10.246.1.8.1.2InetAddressnot-accessiblecurrent
pwPeerMappingPwType
OBJECT-TYPE
The PW type (indicates the emulated service) of this PW.
1.3.6.1.2.1.10.246.1.8.1.3IANAPwTypeTCnot-accessiblecurrent
pwPeerMappingPwID
OBJECT-TYPE
The PW ID of this PW. Zero if the PW is configured manually.
1.3.6.1.2.1.10.246.1.8.1.4PwIDTypenot-accessiblecurrent
pwPeerMappingPwIndex
OBJECT-TYPE
The value that represents the PW in the pwTable.
1.3.6.1.2.1.10.246.1.8.1.5PwIndexTyperead-onlycurrent
pwUpDownNotifEnable
OBJECT-TYPE
If this object is set to true(1), then it enables the emission of pwUp and pwDown notifications; otherwise, these notifications are not emitted.
1.3.6.1.2.1.10.246.1.9TruthValueread-writecurrent
pwDeletedNotifEnable
OBJECT-TYPE
If this object is set to true(1), then it enables the emission of pwDeleted notification; otherwise, this notification is not emitted.
1.3.6.1.2.1.10.246.1.10TruthValueread-writecurrent
pwNotifRate
OBJECT-TYPE
This object defines the maximum number of PW notifications that can be emitted from the device per second.
1.3.6.1.2.1.10.246.1.11Unsigned32read-writecurrent
pwGenFecIndexMappingTable
OBJECT-TYPE
This table enables the reverse mapping of the unique PWid parameters [GroupAttachmentID, LocalAttachmentID, and PeerAttachmentID] and the pwIndex. The table is only applicable for PW using the generalized FEC.
1.3.6.1.2.1.10.246.1.12not-accessiblecurrent
pwGenFecIndexMappingEntry
OBJECT-TYPE
An entry in this table MUST be created by the agent for every PW created by the pwTable for which pwOwner equals genFecSignaling. Implementers need to be aware that if the combined value of pwGenFecIndexMappingAGI, pwGenFecIndexMappingLocalAII, and pwGenFecIndexMappingRemoteAII (OIDs) has more than 113 sub-identifiers, then OIDs of column instances in this table will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
1.3.6.1.2.1.10.246.1.12.1not-accessiblecurrent
pwGenFecIndexMappingAGIType
OBJECT-TYPE
This object is the type of the attachment group identifier (AGI) that this PW belongs to.
1.3.6.1.2.1.10.246.1.12.1.1PwGenIdTypenot-accessiblecurrent
pwGenFecIndexMappingAGI
OBJECT-TYPE
This object is an octet string representing the attachment group identifier (AGI) that this PW belongs to, which typically identifies the VPN ID.
1.3.6.1.2.1.10.246.1.12.1.2PwAttachmentIdentifierTypenot-accessiblecurrent
pwGenFecIndexMappingLocalAIIType
OBJECT-TYPE
This object is the type of the local forwarder attachment individual identifier (AII) to be used by this PW.
1.3.6.1.2.1.10.246.1.12.1.3PwGenIdTypenot-accessiblecurrent
pwGenFecIndexMappingLocalAII
OBJECT-TYPE
This object is an octet string representing the local forwarder attachment individual identifier (AII) to be used by this PW. It is used as the SAII for outgoing signaling messages and the TAII in the incoming messages from the peer.
1.3.6.1.2.1.10.246.1.12.1.4PwAttachmentIdentifierTypenot-accessiblecurrent
pwGenFecIndexMappingRemoteAIIType
OBJECT-TYPE
This object is the type of the remote forwarder attachment individual identifier (AII) to be used by this PW.
1.3.6.1.2.1.10.246.1.12.1.5PwGenIdTypenot-accessiblecurrent
pwGenFecIndexMappingRemoteAII
OBJECT-TYPE
This object is an octet string representing the peer forwarder attachment individual identifier (AII) to be used by this PW. It is used as the TAII for outgoing signaling messages and the SAII in the incoming messages from the peer.
1.3.6.1.2.1.10.246.1.12.1.6PwAttachmentIdentifierTypenot-accessiblecurrent
pwGenFecIndexMappingPwIndex
OBJECT-TYPE
The value that represents the PW in the pwTable.
1.3.6.1.2.1.10.246.1.12.1.7PwIndexTyperead-onlycurrent
pwConformance
OBJECT-IDENTITY
1.3.6.1.2.1.10.246.2
pwGroups
OBJECT-IDENTITY
1.3.6.1.2.1.10.246.2.1
pwCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.10.246.2.2

Notifications

NameOIDStatus
pwDown
NOTIFICATION-TYPE
This notification is generated when the pwOperStatus object for one or more contiguous entries in the pwTable are about to enter the down(2) or lowerLayerDown(6) state from any other state, except for transition from the notPresent(5) state. For the purpose of deciding when these notifications occur, the lowerLayerDown(6) state and the down(2) state are considered to be equivalent; i.e., there is no notification on transition from lowerLayerDown(6) into down(2), and there is a trap on transition from any other state except down(2) (and notPresent) into lowerLayerDown(6). The included values of pwOperStatus MUST each be equal to down(2) or lowerLayerDown(6). The two instances of pwOperStatus in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of cross-connects have transitioned into the down(2) and lowerLayerDown(6) states at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single cross-connect entry, then the instance identifier (and values) of the two pwOperStatus objects MUST be identical.
1.3.6.1.2.1.10.246.0.1current
pwUp
NOTIFICATION-TYPE
This notification is generated when the pwOperStatus object for one or more contiguous entries in the pwTable are about to enter the up(1) state from some other state except the notPresent(5) state and given that the pwDown notification been issued for these entries. The included values of pwOperStatus MUST both be set equal to this new state (i.e., up(1)). The two instances of pwOperStatus in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of cross-connects have transitioned into the up(1) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single cross-connect entry, then the instance identifier (and values) of the two pwOperStatus objects MUST be identical.
1.3.6.1.2.1.10.246.0.2current
pwDeleted
NOTIFICATION-TYPE
This notification is generated when the PW has been deleted, i.e., when the pwRowStatus has been set to destroy(6) or the PW has been deleted by a non-MIB application or due to an auto-discovery process.
1.3.6.1.2.1.10.246.0.3current

Conformance

NameOIDStatus
pwBasicGroup
OBJECT-GROUP
Collection of objects that are required in all implementations that support the PW MIB module.
1.3.6.1.2.1.10.246.2.1.1current
pwPwIdGroup
OBJECT-GROUP
Collection of objects required for PW ID configuration and signaling.
1.3.6.1.2.1.10.246.2.1.2current
pwGeneralizedFecGroup
OBJECT-GROUP
Collection of objects required for generalized FEC configuration and signaling.
1.3.6.1.2.1.10.246.2.1.3current
pwFcsGroup
OBJECT-GROUP
Collection of objects required for FCS retention configuration and signaling.
1.3.6.1.2.1.10.246.2.1.4current
pwFragGroup
OBJECT-GROUP
Collection of objects required for fragmentation configuration and signaling.
1.3.6.1.2.1.10.246.2.1.5current
pwPwStatusGroup
OBJECT-GROUP
Collection of objects required for PW status configuration and signaling.
1.3.6.1.2.1.10.246.2.1.6current
pwGetNextGroup
OBJECT-GROUP
Collection of objects for getting the next available index.
1.3.6.1.2.1.10.246.2.1.7current
pwPriorityGroup
OBJECT-GROUP
Collection of objects for controlling the PW setup and holding priority.
1.3.6.1.2.1.10.246.2.1.8current
pwAttachmentGroup
OBJECT-GROUP
Collection of objects for PW configuration as ifIndex.
1.3.6.1.2.1.10.246.2.1.9current
pwPerformanceGeneralGroup
OBJECT-GROUP
Collection of general objects needed for managing the total running performance parameters.
1.3.6.1.2.1.10.246.2.1.10current
pwPeformance1DayIntervalGroup
OBJECT-GROUP
Collection of objects needed for a PW running 1-day interval performance collection.
1.3.6.1.2.1.10.246.2.1.11current
pwPerformanceIntervalGeneralGroup
OBJECT-GROUP
Collection of general objects needed for managing the interval performance parameters.
1.3.6.1.2.1.10.246.2.1.12current
pwPeformanceIntervalGroup
OBJECT-GROUP
Collection of 32-bit objects needed for PW performance collection in 15-minute intervals.
1.3.6.1.2.1.10.246.2.1.13current
pwHCPeformanceIntervalGroup
OBJECT-GROUP
Collection of HC objects needed for PW performance collection in 15-minute intervals.
1.3.6.1.2.1.10.246.2.1.14current
pwMappingTablesGroup
OBJECT-GROUP
Collection of objects contained in the reverse mapping tables.
1.3.6.1.2.1.10.246.2.1.15current
pwNotificationControlGroup
OBJECT-GROUP
Collection of objects for controlling the PW notifications.
1.3.6.1.2.1.10.246.2.1.16current
pwNotificationGroup
NOTIFICATION-GROUP
Collection of PW notifications objects.
1.3.6.1.2.1.10.246.2.1.17current
pwSignalingGroup
OBJECT-GROUP
Collection of objects for use in implementations that support the PW signaling.
1.3.6.1.2.1.10.246.2.1.18current
pwModuleFullCompliance
MODULE-COMPLIANCE
The compliance statement for agents that provide full support for the PW MIB module. Such devices can then be monitored and configured using this MIB module.
1.3.6.1.2.1.10.246.2.2.1current
pwModuleReadOnlyCompliance
MODULE-COMPLIANCE
The compliance statement for agents that provide read- only support for the PW MIB module. Such devices can then be monitored but cannot be configured using this MIB module.
1.3.6.1.2.1.10.246.2.2.2current