PDN-SYSLOG-MIB
- Registered at
- 1.3.6.1.4.1.1795.2.24.2.31.11.3.6.1.4.1.1795.2.24.2.31.14
- Last updated
- 2003-02-13 00:00
- Organization
- Paradyne Networks MIB Working Group
- Revisions
- 2003-02-13 00:00, 2001-11-15 00:00, 2001-04-10 00:00, 2001-08-09 00:00, 2000-04-24 00:00, 2000-02-05 00:00
- Namespace
- zhone
- Source file
PDN-SYSLOG-MIB- Digest
sha256:d15624672a0636542455879f5573369879a45d912e79d67af17d4ebd3bf458a6
Description
1)Added pdnEntitySyslogTable to be used for entities 2)Added conformance statements.
Contact
Paradyne Networks, Inc. 8545 126th Avenue North Largo, FL 33733 www.paradyne.com General Comments to: mibwg_team@eng.paradyne.com Editor: Dragana Gough - Original Author Editor: Mike Himelstein - Updated Mib Editor: Jesus Pinto - Updated Mib
Imports
| From | Symbols |
|---|---|
| ENTITY-MIB | entPhysicalIndex |
| PDN-HEADER-MIB | pdn-syslog |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ENTITY-MIB IANA-ENTITY-MIB PDN-HEADER-MIB PDN-SYSLOG-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| pdnSyslogStatus OBJECT-TYPE This value allows user to disable or enable syslog event generation. | 1.3.6.1.4.1.1795.2.24.2.31.1.1 | INTEGER {disable(1), enable(2)} | read-write | current |
| pdnSyslogIPAddr OBJECT-TYPE This value is the IP address of a syslog server. If the ip address is known then this can be used for the remote syslog daemon | 1.3.6.1.4.1.1795.2.24.2.31.1.2 | IpAddress | read-write | current |
| pdnSyslogLevel OBJECT-TYPE This value corresponds to a minimum severity level of events that will be logged. | 1.3.6.1.4.1.1795.2.24.2.31.1.3 | INTEGER {emerg(1), err(2), norm(3), info(4)} | read-write | deprecated |
| pdnSyslogPort OBJECT-TYPE This value corresponds to a UDP port number to which system events are sent. The default is 514. | 1.3.6.1.4.1.1795.2.24.2.31.1.4 | Integer32 | read-write | current |
| pdnSyslogSeverityThreshold OBJECT-TYPE This value corresponds to a minimum severity level that a syslog messages can be set. All syslog message with an enum value greater than the threshold will not be sent. The values are obtain from the RFC 3164 The BSD Syslog Protocol: emerg (0) - Emergency: system is unusable alert (1) - Alert: action must be taken immediately critical (2) - Critical: critical conditions error (3) - Error: error conditions warning (4) - Warning: warning conditions notice (5) - Notice: normal but significant condition info (6) - Informational: informational messages debug (7) - Debug: debug-level messages For a more complete description of the severity levels, please reference your Operation Specification Manual for details pertaining to that product. | 1.3.6.1.4.1.1795.2.24.2.31.1.5 | INTEGER {emerg(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6), debug(7)} | read-write | current |
| pdnSyslogRemoteDaemon OBJECT-TYPE This value allows user to disable or enable syslog messages going to a remote daemon. | 1.3.6.1.4.1.1795.2.24.2.31.1.6 | INTEGER {disable(1), enable(2)} | read-write | current |
| pdnSyslogTable OBJECT-TYPE This table supports retrieval of the syslog messages. | 1.3.6.1.4.1.1795.2.24.2.31.1.7 | not-accessible | current | |
| pdnSyslogEntry OBJECT-TYPE An entry in the pdnSyslogTable. | 1.3.6.1.4.1.1795.2.24.2.31.1.7.1 | not-accessible | current | |
| pdnSyslogNumber OBJECT-TYPE This is a sequentially increasing index of syslog messages starting at 1. When the table reaches its maximum size (as defined by pdnSyslogMaxTableSize) then the oldest message will be dropped without renumbering any messages that remain. The index is reset to 1 on a device reset or when the table is cleared (using pdnSyslogClearTable). | 1.3.6.1.4.1.1795.2.24.2.31.1.7.1.1 | Integer32 | not-accessible | current |
| pdnSyslogMessage OBJECT-TYPE The text of the syslog message. | 1.3.6.1.4.1.1795.2.24.2.31.1.7.1.2 | OCTET STRING (SIZE(1024)) | read-only | current |
| pdnSyslogNumOfMsgInTable OBJECT-TYPE This value let the users know how many syslog messages are currently in the syslog table. | 1.3.6.1.4.1.1795.2.24.2.31.1.8 | Integer32 | read-only | current |
| pdnSyslogMaxTableSize OBJECT-TYPE The maximum number of syslog message the syslog table can hold. | 1.3.6.1.4.1.1795.2.24.2.31.1.9 | Integer32 | read-only | current |
| pdnSyslogClearTable OBJECT-TYPE Clears all the entries in the syslog message table. | 1.3.6.1.4.1.1795.2.24.2.31.1.10 | INTEGER {noOp(1), clear(2)} | read-write | current |
| pdnSyslogMsgToConsole OBJECT-TYPE This allows messages to be sent to the device's console port. Note this is intended for debug use only! It is not recommended to be used to monitor syslog message on a regular bases. If one needs to constantly monitor the syslog messages, then they should use the remote syslog daemon, or other user interfaces. | 1.3.6.1.4.1.1795.2.24.2.31.1.11 | INTEGER {disable(1), enable(2)} | read-write | current |
| pdnSyslogRateLimiting OBJECT-TYPE This allows one to enable or disable rate limitiming. When rate limiting is enabled, it prevents the exact same message from being resent within a fixed amount of time. | 1.3.6.1.4.1.1795.2.24.2.31.1.12 | INTEGER {disable(1), enable(2)} | read-write | current |
| pdnEntitySyslogTable OBJECT-TYPE This table supports retrieval of the syslog messages. Each entry corresponds to a message being generated by (or on behalf of) an entity (e.g. port card). | 1.3.6.1.4.1.1795.2.24.2.31.1.13 | not-accessible | current | |
| pdnEntitySyslogEntry OBJECT-TYPE An entry in the pdnEntitySyslogTable | 1.3.6.1.4.1.1795.2.24.2.31.1.13.1 | not-accessible | current | |
| pdnEntitySyslogNumber OBJECT-TYPE This is a sequentially increasing index of syslog messages starting at 1. When the table reaches its maximum size (as defined by pdnSyslogMaxTableSize) then the oldest message will be dropped without renumbering any messages that remain. The index is reset to 1 on a device reset or when the table is cleared (using pdnSyslogClearTable). | 1.3.6.1.4.1.1795.2.24.2.31.1.13.1.1 | Integer32 | not-accessible | current |
| pdnEntitySyslogMessage OBJECT-TYPE The text of the syslog message. | 1.3.6.1.4.1.1795.2.24.2.31.1.13.1.2 | OCTET STRING (SIZE(1024)) | read-only | current |
| pdnSyslogConformance OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.31.14 | |||
| pdnSyslogCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.31.14.1 | |||
| pdnSyslogGroups OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.31.14.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| pdnSyslogCompliance MODULE-COMPLIANCE The compliance statement for configurable attributes for syslog manager. | 1.3.6.1.4.1.1795.2.24.2.31.14.1.1 | current |
| pdnSyslogGroup OBJECT-GROUP A collection of objects that permits configuration and display of syslog messages generated. | 1.3.6.1.4.1.1795.2.24.2.31.14.2.1 | current |
| pdnSyslogOptionalGroup OBJECT-GROUP A collection of syslog messages classified per entities. | 1.3.6.1.4.1.1795.2.24.2.31.14.2.2 | current |
| pdnSyslogDeprecatedGroup OBJECT-GROUP Objects being deprecated should be added to this group | 1.3.6.1.4.1.1795.2.24.2.31.14.2.3 | deprecated |