MIBs Depot

MSERIES-TC

Registered at
1.3.6.1.4.1.30826.1.5
Last updated
2014-02-12 13:27
Organization
SmartOptics
Revisions
2014-02-12 13:27, 2013-10-15 13:41, 2011-12-05 00:00
Namespace
smartoptics
Source file
MSERIES-TC
Digest
sha256:4d415950b3abf126c342d71764915e3d7c7c1e2fd2b5b99a27cd5acbdceb6f78

Description

This is the enterprise specific TC MIB for SmartOptics M-Series

Contact

http://www.smartoptics.com

Imports

FromSymbols
MSERIES-MIBmseries
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

2 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

MSERIES-MIB
MSERIES-TC
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AlarmNotificationType
TEXTUAL-CONVENTION
Type of alarm as defined in ITU-T X.733.
current
AlarmPerceivedSeverity
TEXTUAL-CONVENTION
Alarm severity as defined in ITU-T X.733.
current
AlarmProbableCause
TEXTUAL-CONVENTION
Alarm probable cause as defined in ITU-T X.733.
current
PortMode
TEXTUAL-CONVENTION
Port Mode. normal - The port is active. Alarms are not suppressed. service - the port is in Service Mode. Alarms are beeing suppressed. When service is ready the Port Mode should be set back to normal.
current
PortStatus
TEXTUAL-CONVENTION
The operational state for a port. idle - The port is not activated down - The port traffic is lost. up - There is traffic on the port. high - The port got to high power. low - The port got to low power. eyeSafety - The Line Tx port is in Eye Safety Mode. This means that either the connector on the Line Tx port is not inserted or that you have too strong reflection from the line fiber. cd - Channel detected. ncd - No channel detected.
current
PortType
TEXTUAL-CONVENTION
Port direction. rx - The port direction is receiving(Rx). tx - The port direction is transmitting(Tx). biDi - The port direction is both transmitting and receiving.
current
UnitType
TEXTUAL-CONVENTION
The unit type in the M-Series. nmb - Network Management Board. The controlling board of the M-Series. psu1 - The Power Supply in slot 1 of the M-Series. psu2 - The Power Supply in slot 2 of the M-Series. fan - The Fan of the M-Series. system - The chassis. slaveNmb - Network Management Board of the Cascading system. slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series. slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series. slaveFan - The Fan of the Cascading M-Series.
current