MIBs Depot

Juniper-UNI-ATM-MIB

Registered at
1.3.6.1.4.1.4874.2.2.8
Last updated
2005-11-15 11:33
Organization
Juniper Networks, Inc.
Revisions
2005-11-15 11:33, 2005-08-17 17:26, 2005-02-17 23:15, 2004-12-08 15:22, 2003-12-30 15:07, 2004-02-25 20:23, 2003-09-19 22:01, 2003-07-14 15:37, 2003-01-15 19:32, 2002-08-09 14:03, 2002-08-09 13:40, 2002-01-24 14:00, 2001-12-14 18:04, 2001-11-26 16:39, 2000-11-27 19:51, 2000-08-02 00:00, 2000-05-12 00:00, 2000-01-13 00:00, 1999-08-04 00:00
Namespace
juniper
Source file
Juniper-UNI-ATM-MIB
Digest
sha256:56e7ca9ee339b748cbb9c9b9eae52577ff1c10b9499e5e7449d3a36f3f83baff

Description

The ATM MIB for the Juniper enterprise.

Contact

Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net

Imports

FromSymbols
ATM-FORUM-SNMP-M4-MIBatmfM4VcTestCode, atmfM4VcTestId, atmfM4VcTestObject, atmfM4VcTestResult, atmfM4VcTestType, atmfM4VpTestCode, atmfM4VpTestId, atmfM4VpTestObject, atmfM4VpTestResult, atmfM4VpTestType
ATM-MIBatmVclVci, atmVclVpi, atmVplVpi
ATM-TC-MIBAtmAddr, AtmVcIdentifier, AtmVorXAdminStatus, AtmVpIdentifier
IF-MIBInterfaceIndex, InterfaceIndexOrZero, ifIndex
Juniper-MIBsjuniMibs
Juniper-TCJuniEnable, JuniInterfaceLocationType, JuniInterfaceLocationValue, JuniNextIfIndex
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ATM-FORUM-SNMP-M4-MIB
ATM-MIB
ATM-TC-MIB
ENTITY-MIB
HOST-RESOURCES-MIB
IANA-ENTITY-MIB
IANAifType-MIB
IF-MIB
Juniper-MIBs
Juniper-TC
Juniper-UNI-ATM-MIB
Juniper-UNI-SMI
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
JuniAtmLocationType
TEXTUAL-CONVENTION
Obsolete description of the platform-dependent interpretation of a JuniAtmLocationValue object. This textual convention has been relpaced by Juniper-TC.JuniInterfaceLocationType.
obsolete
JuniAtmLocationValue
TEXTUAL-CONVENTION
Obsolete value of a platform-dependent interface location, represented as an OCTET STRING. A corresponding JuniAtmLocationType object identified the mapping of octets to location elements, e.g. 'slot.port'. This textual convention has been replaced by Juniper-TC.JuniInterfaceLocationValue.
obsolete
JuniAtmNbmaMapName
TEXTUAL-CONVENTION
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system.
current
JuniAtmNbmaMapNameOrNull
TEXTUAL-CONVENTION
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system. Differs from JuniAtmNbmaMapName in that it permits a zero-length string.
current

Objects

NameOIDSyntaxAccessStatus
juniAtmObjects
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1
juniAtmIfLayer
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.1
juniAtmNextIfIndex
OBJECT-TYPE
Coordinate ifIndex value allocation for entries in juniAtmIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
1.3.6.1.4.1.4874.2.2.8.1.1.1JuniNextIfIndexread-onlycurrent
juniAtmIfTable
OBJECT-TYPE
This table contains entries for ATM interfaces present in the system.
1.3.6.1.4.1.4874.2.2.8.1.1.2not-accessiblecurrent
juniAtmIfEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1not-accessiblecurrent
juniAtmIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmNextIfIndex.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.1InterfaceIndexnot-accessiblecurrent
juniAtmIfRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmIfRowStatus juniAtmIfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmIfIndex must have been determined previously, by reading juniAtmNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.2RowStatusread-createcurrent
juniAtmIfLowerIfIndex
OBJECT-TYPE
The ifIndex of an interface over which this ATM interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.3InterfaceIndexOrZeroread-createcurrent
juniAtmIfIlmiVpi
OBJECT-TYPE
The VPI of the ILMI of a major ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.4AtmVpIdentifierread-createcurrent
juniAtmIfIlmiVci
OBJECT-TYPE
The VCI of the ILMI of a major ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.5AtmVcIdentifierread-createcurrent
juniAtmIfIlmiVcd
OBJECT-TYPE
An integer identifier for the ILMI, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.6Integer32 (0..2147483647)read-createcurrent
juniAtmIfIlmiPollFrequency
OBJECT-TYPE
The amount of time in seconds between successive transmissions of ILMI messages on this interface for the purpose of detecting loss of ILMI connectivity. The distinguished value zero disables ILMI connectivity procedures on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.7Integer32 (0..65535)read-createcurrent
juniAtmIfIlmiAdminState
OBJECT-TYPE
The administrative status of ILMI in the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.8INTEGER {disabled(0), enabled(1)}read-createcurrent
juniAtmIfUniVersion
OBJECT-TYPE
Use to specify the User Network Interface (UNI) the router should use when ILMI link auto determination is unsuccesful or ILMI is disabled.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.9INTEGER {uniVersionAutoConfig(0), version3Dot0(1), version3Dot1(2), version4Dot0(3)}read-createcurrent
juniAtmIfOamCellRxAdminState
OBJECT-TYPE
Use to specify the OAM Cell Receive Administrative state on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.10INTEGER {oamCellAdminStateDisabled(0), oamCellAdminStateEnabled(1)}read-createcurrent
juniAtmIfInCells
OBJECT-TYPE
The total number of cells received on this major interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.11Counter64read-onlycurrent
juniAtmIfOutCells
OBJECT-TYPE
The total number of cells transmitted on this major interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.12Counter64read-onlycurrent
juniAtmIfVcCount
OBJECT-TYPE
The total number of circuits configured on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.13Integer32 (0..268431360)read-onlycurrent
juniAtmIfMapGroup
OBJECT-TYPE
The NBMA map group this interface is associated with.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.14JuniAtmNbmaMapNameOrNullread-createcurrent
juniAtmIfCacAdminState
OBJECT-TYPE
The administrative staus of CAC on this ATM major interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.15JuniEnableread-createcurrent
juniAtmIfCacUbrWeight
OBJECT-TYPE
The bandwidth associated with every UBR and UBR with PCR connection configured on the ATM major interface. This value is used for CAC computation. The units are kilo-bits per second (kbps).
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.16Integer32 (0..2147483647)read-createcurrent
juniAtmIfCacSubscriptionBandwidth
OBJECT-TYPE
The subscribed bandwidth of the ATM major interface. If this value is not specified or set to 0, the effective port bandwidth is used. When a Get operation is performed the current effective bandwidth is returned. The units are kilo-bits per second (kbps).
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.17Integer32 (0..2147483647)read-createcurrent
juniAtmIfCacAvailableBandwidth
OBJECT-TYPE
The available bandwidth in Tx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.18Integer32 (0..2147483647)read-onlycurrent
juniAtmIfCacAvailableBandwidthRx
OBJECT-TYPE
The available bandwidth in Rx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.19Integer32 (0..2147483647)read-onlydeprecated
juniAtmIfE164Autoconversion
OBJECT-TYPE
The status of E164 autoconversion feature in the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.20INTEGER {disabled(0), enabled(1)}read-createobsolete
juniAtmIfE164Gateway
OBJECT-TYPE
The status of E164 gateway feature in the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.21INTEGER {disabled(0), enabled(1)}read-createobsolete
juniAtmIfE164OneToOneAddrTrans
OBJECT-TYPE
The status of E164 one-to-one address translation feature in the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.22INTEGER {disabled(0), enabled(1)}read-createobsolete
juniAtmIfOamCellFilter
OBJECT-TYPE
The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards received OAM AIS and RDI cells. The value oamCellFilterAll discards all received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateEnabled, this object has no effect.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.23INTEGER {oamCellFilterAll(0), oamCellFilterAlarm(1)}read-createcurrent
juniAtmIfCacUsedBandwidthUpper
OBJECT-TYPE
The most significant 32 bits of the CAC used bandwidth on the ATM major interface. The least significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthLower.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.24Unsigned32read-onlycurrent
juniAtmIfCacUsedBandwidthLower
OBJECT-TYPE
The least significant 32 bits of the CAC used bandwidth on the ATM major interface. The most significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthUpper.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.25Unsigned32read-onlycurrent
juniAtmIfAssociatedVcClassId
OBJECT-TYPE
The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.2.1.26Unsigned32read-createcurrent
juniAtmPvcStatisticsTable
OBJECT-TYPE
This table contains statistics for PVC entries.
1.3.6.1.4.1.4874.2.2.8.1.1.3not-accessiblecurrent
juniAtmPvcStatisticsEntry
OBJECT-TYPE
Each entry provides statistics on an ATM PVC.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1not-accessiblecurrent
juniAtmPvcStatsIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.1InterfaceIndexnot-accessiblecurrent
juniAtmPvcStatsVpi
OBJECT-TYPE
The VPI of the ATM VCC used by this ATM interface and PVC.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.2AtmVpIdentifiernot-accessiblecurrent
juniAtmPvcStatsVci
OBJECT-TYPE
The VCI of the ATM VCC used by this ATM interface and PVC.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.3AtmVcIdentifiernot-accessiblecurrent
juniAtmPvcStatsInCells
OBJECT-TYPE
Received cells.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.4Counter64read-onlycurrent
juniAtmPvcStatsInCellOctets
OBJECT-TYPE
Received cells octets.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.5Counter64read-onlycurrent
juniAtmPvcStatsInPackets
OBJECT-TYPE
Received AAL PDUs.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.6Counter64read-onlycurrent
juniAtmPvcStatsInPacketOctets
OBJECT-TYPE
Received AAL PDU octets.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.7Counter64read-onlycurrent
juniAtmPvcStatsOutCells
OBJECT-TYPE
Transmitted cells.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.8Counter64read-onlycurrent
juniAtmPvcStatsOutCellOctets
OBJECT-TYPE
Transmitted cell octets.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.9Counter64read-onlycurrent
juniAtmPvcStatsOutPackets
OBJECT-TYPE
Transmitted AAL PDUs.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.10Counter64read-onlycurrent
juniAtmPvcStatsOutPacketOctets
OBJECT-TYPE
Transmitted AAL PDU octets.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.11Counter64read-onlycurrent
juniAtmPvcStatsInCellErrors
OBJECT-TYPE
Received cells dropped due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.12Counter32read-onlycurrent
juniAtmPvcStatsinPacketErrors
OBJECT-TYPE
Received packets dropped due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.13Counter32read-onlycurrent
juniAtmPvcStatsOutCellErrors
OBJECT-TYPE
Cells not transmitted due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.14Counter32read-onlycurrent
juniAtmPvcStatsOutPacketErrors
OBJECT-TYPE
Packets not transmitted due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.15Counter32read-onlycurrent
juniAtmPvcStatsInPacketDiscards
OBJECT-TYPE
Received packets w/o errors discarded.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.16Counter32read-onlycurrent
juniAtmPvcStatsInPacketOctetDiscards
OBJECT-TYPE
Received bytes w/o errors discarded.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.17Counter32read-onlycurrent
juniAtmPvcStatsInPacketUnknownProtocol
OBJECT-TYPE
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
1.3.6.1.4.1.4874.2.2.8.1.1.3.1.18Counter32read-onlycurrent
juniAtmVpTunnelTable
OBJECT-TYPE
This table contains entries for ATM VP Tunnels present in the system.
1.3.6.1.4.1.4874.2.2.8.1.1.4not-accessiblecurrent
juniAtmVpTunnelEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM VP Tunnel.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1not-accessiblecurrent
juniAtmVpTunnelIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface. The value of this object is the same as the juniAtmIfIndex object in the juniAtmIfTable. Entries in this table cannot be created unless the underlying ATM interface entry is created first in the juniAtmIfTable.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1.1InterfaceIndexnot-accessiblecurrent
juniAtmVpTunnelVpi
OBJECT-TYPE
The VPI value for this VP tunnel entry.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1.2AtmVpIdentifiernot-accessiblecurrent
juniAtmVpTunnelKbps
OBJECT-TYPE
The tunnel rate in kilobits per second (kbps) for this entry.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1.3Integer32 (0..2147483647)read-createcurrent
juniAtmVpTunnelRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmVpTunnelRowStatus juniAtmVpTunnelKbps In addition, when creating an entry the following condition must hold: A correponding juniAtmVpTunnelIfIndex value must have been created in the juniAtmIfTable previously.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1.4RowStatusread-createcurrent
juniAtmVpTunnelServiceCategory
OBJECT-TYPE
The ATM service category for the tunnel.
1.3.6.1.4.1.4874.2.2.8.1.1.4.1.5INTEGER {nrtVbr(1), cbr(2)}read-createcurrent
juniAtmIfCapabilityTable
OBJECT-TYPE
This table contains entries for ATM interfaces present in the system.
1.3.6.1.4.1.4874.2.2.8.1.1.5not-accessiblecurrent
juniAtmIfCapabilityEntry
OBJECT-TYPE
Each entry describes the capabilities of an ATM interface. A management client can use this table to determine differences in the configurable level of support across entries in this table.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1not-accessiblecurrent
juniAtmIfCapabilityIndex
OBJECT-TYPE
The ifIndex of the ATM interface. The value of this object is the same as juniAtmIfIndex in the juniAtmIfTable.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.1InterfaceIndexnot-accessiblecurrent
juniAtmIfCapabilityTrafficShaping
OBJECT-TYPE
Indicates whether traffic shaping is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.2TruthValueread-onlycurrent
juniAtmIfCapabilityOam
OBJECT-TYPE
Indicates whether OAM is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.3TruthValueread-onlycurrent
juniAtmIfCapabilityDefaultVcPerVp
OBJECT-TYPE
The default number of VCs per VP for this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.4Integer32 (0..65536)read-onlycurrent
juniAtmIfCapabilityNumVpiVciBits
OBJECT-TYPE
The total range of bits used for constructing VPI/VCI identifiers for this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.5Integer32 (8..28)read-onlycurrent
juniAtmIfCapabilityMaxVcd
OBJECT-TYPE
The maximum configurable value for a VCD on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.6Integer32 (0..2147483647)read-onlycurrent
juniAtmIfCapabilityMaxVpi
OBJECT-TYPE
The maximum configurable value for a VPI on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.7AtmVpIdentifierread-onlycurrent
juniAtmIfCapabilityMaxVci
OBJECT-TYPE
The maximum configurable value for a VCI on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.8AtmVcIdentifierread-onlycurrent
juniAtmIfCapabilityOamCellFilter
OBJECT-TYPE
Indicates whether OAM cell filter is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
1.3.6.1.4.1.4874.2.2.8.1.1.5.1.9TruthValueread-onlycurrent
juniAtmIfSvcSignallingTable
OBJECT-TYPE
This table contains entries for extending the juniAtmIfTable for configuring signalling information for switched virtual connection (SVC).
1.3.6.1.4.1.4874.2.2.8.1.1.6not-accessibledeprecated
juniAtmIfSvcSignallingEntry
OBJECT-TYPE
Each entry provides configuration parameters for ATM signalling on the interface.
1.3.6.1.4.1.4874.2.2.8.1.1.6.1not-accessibledeprecated
juniAtmIfSvcSignallingVpi
OBJECT-TYPE
The VPI identifier of the ATM circuit used for signalling for this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.6.1.1AtmVpIdentifierread-writedeprecated
juniAtmIfSvcSignallingVci
OBJECT-TYPE
The VCI identifier of the ATM circuit used for signalling for this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.6.1.2AtmVcIdentifierread-writedeprecated
juniAtmIfSvcSignallingVcd
OBJECT-TYPE
An integer identifier for the ATM circuit used for signalling on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.6.1.3Integer32 (0..2147483647)read-writedeprecated
juniAtmIfSvcSignallingAdminStatus
OBJECT-TYPE
The administrative status of signalling on the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.6.1.4AtmVorXAdminStatusread-writedeprecated
juniAtmIfPnniRccTable
OBJECT-TYPE
This table contains entries for extending the juniAtmIfTable for configuring PNNI RCC information.
1.3.6.1.4.1.4874.2.2.8.1.1.7not-accessibleobsolete
juniAtmIfPnniRccEntry
OBJECT-TYPE
Each entry provides configuration parameters for PNNI RCC on the interface.
1.3.6.1.4.1.4874.2.2.8.1.1.7.1not-accessibleobsolete
juniAtmIfPnniRccVpi
OBJECT-TYPE
The VPI identifier of the ATM circuit used for PNNI RCC on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.7.1.1AtmVpIdentifierread-writeobsolete
juniAtmIfPnniRccVci
OBJECT-TYPE
The VCI identifier of the ATM circuit used for PNNI RCC on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.7.1.2AtmVcIdentifierread-writeobsolete
juniAtmIfPnniRccVcd
OBJECT-TYPE
An integer identifier for the ATM circuit used for PNNI RCC on this interface.
1.3.6.1.4.1.4874.2.2.8.1.1.7.1.3Integer32 (0..2147483647)read-writeobsolete
juniAtmIfPnniRccAdminStatus
OBJECT-TYPE
The administrative status of PNNI on the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.7.1.4AtmVorXAdminStatusread-writeobsolete
juniAtmOamF4FlowEndToEndCfgTable
OBJECT-TYPE
This table contains entries for F4 OAM end-to-end flows configured.
1.3.6.1.4.1.4874.2.2.8.1.1.8not-accessiblecurrent
juniAtmOamF4FlowEndToEndCfgEntry
OBJECT-TYPE
Each entry provides configuration parameters for one F4 OAM end-to-end flow configured for each VPI.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1not-accessiblecurrent
juniAtmOamF4FlowEndToEndIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface to configure the F4 OAM end-to-end flow.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.1InterfaceIndexnot-accessiblecurrent
juniAtmOamF4FlowEndToEndVpi
OBJECT-TYPE
Select the VPI for F4 OAM end-to-end flow configuration.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.2Integer32 (0..255)not-accessiblecurrent
juniAtmOamF4FlowEndToEndLoopbackTimer
OBJECT-TYPE
Configure the timer for sending the F4 flow end-to-end loopback OAM cells. Setting this value will enable sending the F4 end cells on the circuit. It is not allowed to set the value to -1 and whenever it is read as -1 that means sending end loopback is not enabled. Setting the loopback timer, other than -1, will enable sending the end cells.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.3Integer32 (-1..600)read-createcurrent
juniAtmOamF4FlowEndToEndCCSink
OBJECT-TYPE
Enable/Disable F4 flow end-to-end continuity check sink end point for this VP.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.4TruthValueread-createcurrent
juniAtmOamF4FlowEndToEndCCSource
OBJECT-TYPE
Enable/Disable F4 flow end-to-end continuity check source end point for this VP.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.5TruthValueread-createcurrent
juniAtmOamF4FlowEndToEndRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowEndToEndRowStatus F4 OAM end loopback and CC tests are mutually exclusive, enabling one will disable the other automatically. So, it is not allowed either at the circuit creation time or after the circuit creation to issue a request to enable end-to-end loopback and CC tests simultaneouly. Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous.
1.3.6.1.4.1.4874.2.2.8.1.1.8.1.6RowStatusread-createcurrent
juniAtmOamF4FlowSegmentCfgTable
OBJECT-TYPE
This table contains entries for F4 OAM Segment flows configured.
1.3.6.1.4.1.4874.2.2.8.1.1.9not-accessiblecurrent
juniAtmOamF4FlowSegmentCfgEntry
OBJECT-TYPE
Each entry provides configuration parameters for one F4 OAM Segment flow configured for each VPI.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1not-accessiblecurrent
juniAtmOamF4FlowSegmentIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface to configure the F4 OAM segment flow.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1.1InterfaceIndexnot-accessiblecurrent
juniAtmOamF4FlowSegmentVpi
OBJECT-TYPE
Select the VPI for F4 OAM segment flow configuration.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1.2Integer32 (0..255)not-accessiblecurrent
juniAtmOamF4FlowSegmentCCSink
OBJECT-TYPE
Enable/Disable F4 flow segment continuity check sink end point for this VP.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1.3TruthValueread-createcurrent
juniAtmOamF4FlowSegmentCCSource
OBJECT-TYPE
Enable/Disable F4 flow segment continuity check source end point for this VP.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1.4TruthValueread-createcurrent
juniAtmOamF4FlowSegmentRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowSegmentRowStatus Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous. F4 OAM segment loopback test is not supported.
1.3.6.1.4.1.4874.2.2.8.1.1.9.1.5RowStatusread-createcurrent
juniAtmVpDescrTable
OBJECT-TYPE
This table contains entries for ATM VP Description present in the system. The user can configure a description of up to 32 characters for every VP in the ATM interface. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
1.3.6.1.4.1.4874.2.2.8.1.1.10not-accessiblecurrent
juniAtmVpDescrEntry
OBJECT-TYPE
Each entry contains the description of the VP.
1.3.6.1.4.1.4874.2.2.8.1.1.10.1not-accessiblecurrent
juniAtmVpDescription
OBJECT-TYPE
The description for this VP. The default value of this object is null string.
1.3.6.1.4.1.4874.2.2.8.1.1.10.1.1SnmpAdminString (SIZE(0..32))read-writecurrent
juniAtmF4FlowOamEndToEndStatsTable
OBJECT-TYPE
This table contains entries for F4 flow EndToEnd OAM circuits stats.
1.3.6.1.4.1.4874.2.2.8.1.1.11not-accessiblecurrent
juniAtmF4FlowOamEndToEndStatsEntry
OBJECT-TYPE
Each entry provides stats for one F4 OAM circuit for each VPI.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1not-accessiblecurrent
juniAtmF4FlowInOamEndAisCells
OBJECT-TYPE
Received end-to-end OAM F4 AIS cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.1Counter32read-onlycurrent
juniAtmF4FlowInOamEndRdiCells
OBJECT-TYPE
Received end-to-end OAM F4 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.2Counter32read-onlycurrent
juniAtmF4FlowInOamEndCCCells
OBJECT-TYPE
Received end-to-end OAM F4 CC cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.3Counter32read-onlycurrent
juniAtmF4FlowInOamEndCCActDeActCells
OBJECT-TYPE
Received end-to-end OAM F4 activation/de-activation cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.4Counter32read-onlycurrent
juniAtmF4FlowInOamEndLoopbackCells
OBJECT-TYPE
Total received OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndInLoopbackCmds and juniAtmF4FlowEndToEndInLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.5Counter32read-onlycurrent
juniAtmF4FlowOutEndRdiCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.6Counter32read-onlycurrent
juniAtmF4FlowOutEndCCCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 CC cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.7Counter32read-onlycurrent
juniAtmF4FlowOutEndCCActDeActCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 activation/de-activation cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.8Counter32read-onlycurrent
juniAtmF4FlowOutEndToEndLoopbackCells
OBJECT-TYPE
Total transmitted OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndOutLoopbackCmds and juniAtmF4FlowEndToEndOutLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.9Counter32read-onlycurrent
juniAtmF4FlowEndActualLoopbackFreq
OBJECT-TYPE
Actual end-to-end loopback Frequecy calculated for OAM cells transmission.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.10Integer32 (0..65535)read-onlycurrent
juniAtmF4FlowEndLastTimeChanged
OBJECT-TYPE
Last time end-to-end F4 OAM flow got changed.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.11TimeTicksread-onlycurrent
juniAtmF4FlowOamEndVpOperationState
OBJECT-TYPE
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.12INTEGER {vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)}read-onlycurrent
juniAtmF4FlowOamEndVpAdminState
OBJECT-TYPE
End-to-end VP admin state.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.13INTEGER {down(0), up(1)}read-onlycurrent
juniAtmF4FlowEndInOamCells
OBJECT-TYPE
Received end-to-end OAM F4 loopback cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.14Counter32read-onlycurrent
juniAtmF4FlowEndOutOamCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 loopback cells.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.15Counter32read-onlycurrent
juniAtmF4FlowEndInOamCellsDropped
OBJECT-TYPE
Received end-to-end OAM cells that were dropped.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.16Counter32read-onlycurrent
juniAtmF4FlowEndToEndInLoopbackCmds
OBJECT-TYPE
Received OAM F4 end-to-end loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.17Counter32read-onlycurrent
juniAtmF4FlowEndToEndInLoopbackRsps
OBJECT-TYPE
Received OAM F4 end-to-end loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.18Counter32read-onlycurrent
juniAtmF4FlowEndToEndOutLoopbackCmds
OBJECT-TYPE
Transmitted OAM F4 end-to-end loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.19Counter32read-onlycurrent
juniAtmF4FlowEndToEndOutLoopbackRsps
OBJECT-TYPE
Transmitted OAM F4 end-to-end loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.1.11.1.20Counter32read-onlycurrent
juniAtmF4FlowOamSegmentStatsTable
OBJECT-TYPE
This table contains entries for F4 flow Segment OAM circuits stats.
1.3.6.1.4.1.4874.2.2.8.1.1.12not-accessiblecurrent
juniAtmF4FlowOamSegmentStatsEntry
OBJECT-TYPE
Each entry provides stats for one F4 OAM circuit for each VPI.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1not-accessiblecurrent
juniAtmF4FlowInOamSegmentAisCells
OBJECT-TYPE
Received end-to-end OAM F4 AIS cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.1Counter32read-onlycurrent
juniAtmF4FlowInOamSegmentRdiCells
OBJECT-TYPE
Received end-to-end OAM F4 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.2Counter32read-onlycurrent
juniAtmF4FlowInOamSegmentCCCells
OBJECT-TYPE
Received end-to-end OAM F4 CC cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.3Counter32read-onlycurrent
juniAtmF4FlowInOamSegmentCCActDeActCells
OBJECT-TYPE
Received end-to-end OAM F4 activation/de-activation cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.4Counter32read-onlycurrent
juniAtmF4FlowInOamSegmentLoopbackCells
OBJECT-TYPE
Total received OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentInLoopbackCmds and juniAtmF4FlowSegmentInLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.5Counter32read-onlycurrent
juniAtmF4FlowOutSegmentRdiCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.6Counter32read-onlycurrent
juniAtmF4FlowOutSegmentCCCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 CC cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.7Counter32read-onlycurrent
juniAtmF4FlowOutSegmentCCActDeActCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 activation/de-activation cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.8Counter32read-onlycurrent
juniAtmF4FlowOutSegmentLoopbackCells
OBJECT-TYPE
Total transmitted OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentOutLoopbackCmds and juniAtmF4FlowSegmentOutLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.9Counter32read-onlycurrent
juniAtmF4FlowSegmentLastTimeChanged
OBJECT-TYPE
Last time end-to-end F4 OAM flow got changed.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.10TimeTicksread-onlycurrent
juniAtmF4FlowOamSegmentVpOperationState
OBJECT-TYPE
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.11INTEGER {vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)}read-onlycurrent
juniAtmF4FlowOamSegmentVpAdminState
OBJECT-TYPE
Segment VP admin state.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.12INTEGER {down(0), up(1)}read-onlycurrent
juniAtmF4FlowSegmentInOamCells
OBJECT-TYPE
Received end-to-end OAM F4 loopback cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.13Counter32read-onlycurrent
juniAtmF4FlowSegmentOutOamCells
OBJECT-TYPE
Transmitted end-to-end OAM F4 loopback cells.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.14Counter32read-onlycurrent
juniAtmF4FlowSegmentInOamCellsDropped
OBJECT-TYPE
Received end-to-end OAM cells that were dropped.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.15Counter32read-onlycurrent
juniAtmF4FlowSegmentInLoopbackCmds
OBJECT-TYPE
Received OAM F4 segment loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.16Counter32read-onlycurrent
juniAtmF4FlowSegmentInLoopbackRsps
OBJECT-TYPE
Received OAM F4 segment loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.17Counter32read-onlycurrent
juniAtmF4FlowSegmentOutLoopbackCmds
OBJECT-TYPE
Transmitted OAM F4 segment loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.18Counter32read-onlycurrent
juniAtmF4FlowSegmentOutLoopbackRsps
OBJECT-TYPE
Transmitted OAM F4 segment loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.1.12.1.19Counter32read-onlycurrent
juniAtmMartiniTimeoutTimerTable
OBJECT-TYPE
This table contains entries for ATM Martini cell aggregation timeout detection. The user can configure timeout values for three timers. A row exists for every separate timer supported. These rows get created as soon as the ERX system comes up.
1.3.6.1.4.1.4874.2.2.8.1.1.13not-accessiblecurrent
juniAtmMartiniTimeoutTimerEntry
OBJECT-TYPE
Each entry contains the timeout value of ATM Martini cell aggregation timer.
1.3.6.1.4.1.4874.2.2.8.1.1.13.1not-accessiblecurrent
juniAtmMartiniTimeoutTimerIndex
OBJECT-TYPE
The ATM Martini cell aggregation timeout timer identifier.
1.3.6.1.4.1.4874.2.2.8.1.1.13.1.1INTEGER {timer1(1), timer2(2), timer3(3)}not-accessiblecurrent
juniAtmMartiniTimeoutTimerValue
OBJECT-TYPE
The ATM Martini cell aggregation timeout timer value in microseconds.
1.3.6.1.4.1.4874.2.2.8.1.1.13.1.2Integer32 (100..4095)read-writecurrent
juniAtmVpStatsTable
OBJECT-TYPE
This table contains entries for ATM VP statistics present in the system. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
1.3.6.1.4.1.4874.2.2.8.1.1.14not-accessiblecurrent
juniAtmVpStatsEntry
OBJECT-TYPE
Each entry contain the VP statistics.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1not-accessiblecurrent
juniAtmVpStatsIfIndex
OBJECT-TYPE
The ifIndex of the ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.1InterfaceIndexnot-accessiblecurrent
juniAtmVpStatsVpi
OBJECT-TYPE
The VPI value of the virtual path for which statistics are retrieved.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.2AtmVpIdentifiernot-accessiblecurrent
juniAtmVpStatsInCells
OBJECT-TYPE
Received cells.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.3Counter64read-onlycurrent
juniAtmVpStatsInPackets
OBJECT-TYPE
Received AAL5 PDUs.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.4Counter64read-onlycurrent
juniAtmVpStatsInPacketOctets
OBJECT-TYPE
Received AAL5 PDU octets.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.5Counter64read-onlycurrent
juniAtmVpStatsOutCells
OBJECT-TYPE
Transmitted cells.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.6Counter64read-onlycurrent
juniAtmVpStatsOutPackets
OBJECT-TYPE
Transmitted AAL5 PDUs
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.7Counter64read-onlycurrent
juniAtmVpStatsOutPacketOctets
OBJECT-TYPE
Transmitted AAL5 PDU octets.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.8Counter64read-onlycurrent
juniAtmVpStatsInPacketErrors
OBJECT-TYPE
Received packets dropped due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.9Counter32read-onlycurrent
juniAtmVpStatsOutPacketErrors
OBJECT-TYPE
Packets not transmitted due to errors.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.10Counter32read-onlycurrent
juniAtmVpStatsInPacketDiscards
OBJECT-TYPE
Received packets without errors discarded.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.11Counter32read-onlycurrent
juniAtmVpStatsInPacketOctetDiscards
OBJECT-TYPE
Received bytes without errors discarded.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.12Counter32read-onlycurrent
juniAtmVpStatsInPacketUnknownProtocol
OBJECT-TYPE
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.13Counter32read-onlycurrent
juniAtmVpStatsCrcErrors
OBJECT-TYPE
Received packets that are discarded because of check sum erros
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.14Counter32read-onlycurrent
juniAtmVpStatsSarTimeouts
OBJECT-TYPE
Received packets that are discarded because of SAR timeout
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.15Counter32read-onlycurrent
juniAtmVpStatsOverSizedPackets
OBJECT-TYPE
Over sized packets that are received on this VP.
1.3.6.1.4.1.4874.2.2.8.1.1.14.1.16Counter32read-onlycurrent
juniAtmAal5IfLayer
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.2
juniAtmAal5NextIfIndex
OBJECT-TYPE
Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
1.3.6.1.4.1.4874.2.2.8.1.2.1JuniNextIfIndexread-onlycurrent
juniAtmAal5IfTable
OBJECT-TYPE
This table contains entries for ATM AAL5 interfaces present in the system.
1.3.6.1.4.1.4874.2.2.8.1.2.2not-accessiblecurrent
juniAtmAal5IfEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM AAL5 interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
1.3.6.1.4.1.4874.2.2.8.1.2.2.1not-accessiblecurrent
juniAtmAal5IfIndex
OBJECT-TYPE
The ifIndex of the ATM AAL5 interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmAal5NextIfIndex.
1.3.6.1.4.1.4874.2.2.8.1.2.2.1.1InterfaceIndexnot-accessiblecurrent
juniAtmAal5IfRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmAal5IfRowStatus juniAtmAal5IfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmAal5IfIndex must have been determined previously, by reading juniAtmAal5NextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
1.3.6.1.4.1.4874.2.2.8.1.2.2.1.2RowStatusread-createcurrent
juniAtmAal5IfLowerIfIndex
OBJECT-TYPE
The ifIndex of an ATM interface over which this ATM AAL5 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
1.3.6.1.4.1.4874.2.2.8.1.2.2.1.3InterfaceIndexOrZeroread-createcurrent
juniAtmBulkCircuitsNameTable
OBJECT-TYPE
The entries in this table provide mappings of ATM bulk virtual circuit range names to local integer identifiers for those profiles. These integers are used as indexes into other MIB tables containing profile configuration parameters associated with the same profile name.
1.3.6.1.4.1.4874.2.2.8.1.2.3not-accessiblecurrent
juniAtmBulkCircuitsNameEntry
OBJECT-TYPE
A mapping of a ATM bulk virtual circuit range name to an integer identifier for that name.
1.3.6.1.4.1.4874.2.2.8.1.2.3.1not-accessiblecurrent
juniAtmBulkCircuitsNameAal5IfIndex
OBJECT-TYPE
The ifIndex of the ATM AAL5 interface.
1.3.6.1.4.1.4874.2.2.8.1.2.3.1.1InterfaceIndexnot-accessiblecurrent
juniAtmBulkCircuitsNameName
OBJECT-TYPE
The ATM bulk virtual circuit range name uniquely identifying this entry.
1.3.6.1.4.1.4874.2.2.8.1.2.3.1.2DisplayString (SIZE(1..80))not-accessiblecurrent
juniAtmBulkCircuitsNameRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Creating an entry in this table creates corresponding entry in juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes corresponding entries in juniAtmBulkCircuitsIdTable, juniAtmBulkCircuitsTable and juniAtmProfileOverrideAssignIfCircuitTable.
1.3.6.1.4.1.4874.2.2.8.1.2.3.1.3RowStatusread-createcurrent
juniAtmBulkCircuitsNameId
OBJECT-TYPE
The integer identifier associated with this ATM bulk virtual circuit range name. This value of this identifier is assigned by the device when an entry in this table is created.
1.3.6.1.4.1.4874.2.2.8.1.2.3.1.4Unsigned32read-onlycurrent
juniAtmBulkCircuitsIdTable
OBJECT-TYPE
Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk virtual circuit names.
1.3.6.1.4.1.4874.2.2.8.1.2.4not-accessiblecurrent
juniAtmBulkCircuitsIdEntry
OBJECT-TYPE
A mapping of an integer identifier to a ATM bulk virtual circuit name.
1.3.6.1.4.1.4874.2.2.8.1.2.4.1not-accessiblecurrent
juniAtmBulkCircuitsIdAal5IfIndex
OBJECT-TYPE
The ifIndex of the ATM AAL5 interface.
1.3.6.1.4.1.4874.2.2.8.1.2.4.1.1InterfaceIndexnot-accessiblecurrent
juniAtmBulkCircuitsIdId
OBJECT-TYPE
The integer identifier associated with this ATM bulk virtual circuit name.
1.3.6.1.4.1.4874.2.2.8.1.2.4.1.2Unsigned32not-accessiblecurrent
juniAtmBulkCircuitsIdName
OBJECT-TYPE
The ATM bulk virtual circuit name having the associated identifier.
1.3.6.1.4.1.4874.2.2.8.1.2.4.1.3DisplayString (SIZE(1..80))read-onlycurrent
juniAtmBulkCircuitsIdNextInstance
OBJECT-TYPE
The next available instance value for juniAtmBulkCircuitsEntry.
1.3.6.1.4.1.4874.2.2.8.1.2.4.1.4Unsigned32read-onlycurrent
juniAtmBulkCircuitsTable
OBJECT-TYPE
This table contains bulk virtual circuit range parameters.
1.3.6.1.4.1.4874.2.2.8.1.2.5not-accessiblecurrent
juniAtmBulkCircuitsEntry
OBJECT-TYPE
Each entry describes the characteristics of VC range.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1not-accessiblecurrent
juniAtmBulkCircuitsAal5IfIndex
OBJECT-TYPE
The ifIndex of the ATM AAL5 interface on which this bulk virtual circuit sub-range is created.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.1InterfaceIndexnot-accessiblecurrent
juniAtmBulkCircuitsId
OBJECT-TYPE
The integer identifier associated with this ATM bulk virtual circuit name.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.2Unsigned32not-accessiblecurrent
juniAtmBulkCircuitsInstance
OBJECT-TYPE
The unique identifier of the ATM bulk virtual circuit sub-range.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.3Unsigned32not-accessiblecurrent
juniAtmBulkCircuitsRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since none of the VPI/VCI minimum and maximum values have default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI/VCI minimum and maximum values can only be configured upon creation. Deleting an entry in this table deletes corresponding entries in juniAtmProfileOverrideAssignIfCircuitTable.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4RowStatusread-createcurrent
juniAtmBulkCircuitsMinVpi
OBJECT-TYPE
The minimum value of VPI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVpi.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.5AtmVpIdentifierread-createcurrent
juniAtmBulkCircuitsMaxVpi
OBJECT-TYPE
The maximum value of VPI for this cicuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVpi.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.6AtmVpIdentifierread-createcurrent
juniAtmBulkCircuitsMinVci
OBJECT-TYPE
The minimum value of VCI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVci.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.7AtmVcIdentifierread-createcurrent
juniAtmBulkCircuitsMaxVci
OBJECT-TYPE
The maximum value of VCI for this circuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVci.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.8AtmVcIdentifierread-createcurrent
juniAtmBulkCircuitsAdminState
OBJECT-TYPE
The administrative status of this circuit sub-range.
1.3.6.1.4.1.4874.2.2.8.1.2.5.1.9JuniEnableread-createcurrent
juniAtmProfileOverrideAssignIfCircuitTable
OBJECT-TYPE
Table providing overriding profile assignment to a circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci. The entries in this table specify which profile to use when creating and configuring a dynamic interface above a circuit specified by vpi and vci. This entry is effective when the circuit specified by juniAtmProfileOverrideAssignIfCircuitAal5Index, juniAtmProfileOverrideAssignIfCircuitRangeId, juniAtmProfileOverrideAssignIfCircuitVpi, juniAtmProfileOverrideAssignIfCircuitVci is part of bulk-configuration.
1.3.6.1.4.1.4874.2.2.8.1.2.6not-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitEntry
OBJECT-TYPE
An assignment of a profile to a circuit configured as part of bulk-configuration on an AAL5 interface.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1not-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitAal5Index
OBJECT-TYPE
The ifIndex of the AAL5 interface to which the profile is assigned.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.1InterfaceIndexnot-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitRangeId
OBJECT-TYPE
The integer identifier associated with the ATM bulk circuit configuration.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.2Unsigned32not-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitVpi
OBJECT-TYPE
The VPI value of the circuit to which the profile is assigned.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.3AtmVpIdentifiernot-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitVci
OBJECT-TYPE
The VCI value of the circuit to which the profile is assigned.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.4AtmVcIdentifiernot-accessiblecurrent
juniAtmProfileOverrideAssignIfCircuitRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since the VPI, VCI and profileId values do not have any default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI, VCI and profileId values can only be configured upon creation. None of these values can be modified except by deleting the entry.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.5RowStatusread-createcurrent
juniAtmProfileOverrideAssignIfCircuitProfileId
OBJECT-TYPE
The ID of the profile assigned to the circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.6Unsigned32read-createcurrent
juniAtmProfileOverrideAssignIfCircuitOperStatus
OBJECT-TYPE
The operational status of the profile override assignment identified by this entry. It returns inactive(0), if a static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will not be used to configure upper dynamic interfaces. It returns active(1), if no static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will be used to configure upper dynamic interfaces.
1.3.6.1.4.1.4874.2.2.8.1.2.6.1.7INTEGER {inactive(0), active(1)}read-onlycurrent
juniAtmSubIfLayer
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.3
juniAtmSubIfNextIfIndex
OBJECT-TYPE
Coordinate ifIndex value allocation for entries in juniAtmSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
1.3.6.1.4.1.4874.2.2.8.1.3.1JuniNextIfIndexread-onlycurrent
juniAtmSubIfTable
OBJECT-TYPE
This table contains entries for ATM Subinterfaces present in the system.
1.3.6.1.4.1.4874.2.2.8.1.3.2not-accessiblecurrent
juniAtmSubIfEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM Subinterface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1not-accessiblecurrent
juniAtmSubIfIndex
OBJECT-TYPE
The ifIndex of the ATM Subinterface. When creating entries in this table, suitable values for this object are determined by reading juniAtmSubNextIfIndex.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.1InterfaceIndexnot-accessiblecurrent
juniAtmSubIfRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfRowStatus juniAtmSubIfLowerIndex In addition, when creating an entry the following condition must hold: A value for juniAtmSubIfIndex must have been determined previously, by reading juniAtmSubIfNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.2RowStatusread-createcurrent
juniAtmSubIfDistinguisher
OBJECT-TYPE
An integer identifier for the subinterface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among subinterfaces configured on the same underlying ATM adaptation layer. The upper bound for the value is further constrained to be identical with the maximum number of subinterfaces supported by the lower interface. If this object is not configured, a value will be allocated internally and can be queried after table entry creation has succeeded.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.3Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfLowerIfIndex
OBJECT-TYPE
The ifIndex of an ATM AAL5 interface over which this ATM subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.4InterfaceIndexOrZeroread-createcurrent
juniAtmSubIfNbma
OBJECT-TYPE
The NBMA administrative setting. Setting this value of this object to true(1) will enable multipoint access on this interface. Setting the value to false(2), will enable point to point access on this interface.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.5TruthValueread-createcurrent
juniAtmSubIfAddress
OBJECT-TYPE
Specifies the local ATM NSAP address of the circuit. A GET operation returns a full 20-octet NSAP. A SET operation only requires 7 octets, since the prefix can be implied.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.6AtmAddr (SIZE(0 | 7 | 20))read-createdeprecated
juniAtmSubIfMtu
OBJECT-TYPE
The size of the largest packet which can be sent/received on the interface, specified in octets.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.7Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfAdvisoryRxSpeed
OBJECT-TYPE
Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for underlying circuit receive speed.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.8Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfMartiniMaxCellsPerPacket
OBJECT-TYPE
The number of cells that can be aggregated in a single ATM Martini packet in cell-relay mode.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.9Integer32 (1..190)read-createcurrent
juniAtmSubIfMartiniTimeoutTimerId
OBJECT-TYPE
The timer identifier used to abandon cell aggregation when no cells are supplied for transmission in ATM Martini cell-relay mode.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.10Integer32 (1..3)read-createcurrent
juniAtmSubIfAssociatedVcClassId
OBJECT-TYPE
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
1.3.6.1.4.1.4874.2.2.8.1.3.2.1.11Unsigned32read-createcurrent
juniAtmSubIfVccTable
OBJECT-TYPE
This table contains entries for ATM VCCs configured on ATM subinterfaces present in the system. An implementation may constrain the number of VCCs permitted to be configured per ATM Subinterface; in particular, an implementation may restrict each ATM Subinterface to have a single VCC. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
1.3.6.1.4.1.4874.2.2.8.1.3.3not-accessiblecurrent
juniAtmSubIfVccEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM subinterface VCC.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1not-accessiblecurrent
juniAtmSubIfVccVpi
OBJECT-TYPE
The VPI of the ATM VCC used by this subinterface.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.1AtmVpIdentifiernot-accessiblecurrent
juniAtmSubIfVccVci
OBJECT-TYPE
The VCI of the ATM VCC used by this subinterface.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.2AtmVcIdentifiernot-accessiblecurrent
juniAtmSubIfVccRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfVccRowStatus In addition, when creating an entry the following conditions must hold: The ATM Subinterface identified by juniAtmSubIfIndex must exist. A positive value configured for juniAtmSubIfVccVcd must not already be assigned to an existing VCC. For each value of juniAtmSubIfVccServiceCategory, additional dependent objects in the entry require configuration as identified here: juniAtmSubIfVccServiceCategory Requires configuration of: ------------------------------------------------------------ ubr <none> ubrPcr juniAtmSubIfVccPcr nrtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs cbr juniAtmSubIfVccPcr rtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs ------------------------------------------------------------ Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.3RowStatusread-createcurrent
juniAtmSubIfVccVcd
OBJECT-TYPE
An integer identifier for the circuit, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among VCCs configured on the same underlying ATM interface. If this object is not configured, or is configured with a value of zero, a value will be allocated internally and can be queried after table entry creation has succeeded.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.4Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfVccType
OBJECT-TYPE
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VcMux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.5INTEGER {rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)}read-createcurrent
juniAtmSubIfVccServiceCategory
OBJECT-TYPE
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.6INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)}read-createcurrent
juniAtmSubIfVccPcr
OBJECT-TYPE
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.7Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfVccScr
OBJECT-TYPE
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.8Integer32 (0..2147483647)read-createcurrent
juniAtmSubIfVccMbs
OBJECT-TYPE
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.9Integer32 (0..16777215)read-createcurrent
juniAtmSubIfInverseArp
OBJECT-TYPE
Enables the inverse ARP protocol on this VCC; true(1) enables the protocol, false(2) disables it.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.10TruthValueread-createcurrent
juniAtmSubIfInverseArpRefresh
OBJECT-TYPE
The refresh rate in minutes between inverse ARP protocol messages.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.11Integer32 (0..60)read-createcurrent
juniAtmSubIfVccAssociatedVcClassId
OBJECT-TYPE
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this VC.
1.3.6.1.4.1.4874.2.2.8.1.3.3.1.12Unsigned32read-createcurrent
juniAtmCircuitOamTable
OBJECT-TYPE
This table contains circuit OAM data for a PVC.
1.3.6.1.4.1.4874.2.2.8.1.3.4not-accessiblecurrent
juniAtmCircuitOamEntry
OBJECT-TYPE
Each entry provides OAM data on an ATM PVC.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1not-accessiblecurrent
juniAtmCircuitOamIfIndex
OBJECT-TYPE
The ifIndex of the ATM subinterface.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.1InterfaceIndexnot-accessiblecurrent
juniAtmCircuitOamVpi
OBJECT-TYPE
The VPI of the ATM VCC used by this ATM interface and PVC.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.2AtmVpIdentifiernot-accessiblecurrent
juniAtmCircuitOamVci
OBJECT-TYPE
The VCI of the ATM VCC used by this ATM interface and PVC.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.3AtmVcIdentifiernot-accessiblecurrent
juniAtmCircuitOamAdminStatus
OBJECT-TYPE
The administrative state of OAM for the interface identified by this entry.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.4INTEGER {oamAdminStateDisabled(1), oamAdminStateEnabled(2)}read-writecurrent
juniAtmCircuitOamLoopbackOperStatus
OBJECT-TYPE
The operational status of OAM for the interface identified by this entry. oamOperStatusNotSupported(0) - OAM not supported on this interface oamOperStatusDisabled(1) - VC integrity disabled oamOperStatusSent(2) - Loopback sent, awaiting response oamOperStatusReceived(3) - Loopback response received, awaiting frequency oamOperStatusFailed(4) - Loopback response not received, or invalid response received
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.5INTEGER {oamOperStatusNotSupported(0), oamOperStatusDisabled(1), oamOperStatusSent(2), oamOperStatusReceived(3), oamOperStatusFailed(4)}read-onlycurrent
juniAtmCircuitVcOamOperStatus
OBJECT-TYPE
The OAM VC operational status of this entry. oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS oamVcOperStateRdiState(1) - RDI cell received oamVcOperStateDownRetry(2) - OAM loopback failed, using retry frequency to verify that the VC is really down oamVcOperStateUpRetry(3) - OAM loopback successful, using retry frequency to verify that the VC is really up oamVcOperStateUp(4) - OAM loopback successful after up retry verification oamVcOperStateDown(5) - OAM loopback failed after down retry verification oamVcOperStateNotManaged(6)- No verification via loopback cells being performed oamVcOperStateVpAis(7) - F4 AIS cell received oamVcOperStateVpRdi(8) - F4 RDI cell received oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure oamVcOperStateSegAis(11) - Segment AIS cell received oamVcOperStateSegRdi(12) - Segment RDI cell received oamVcOperStateGenAis(13) - Connection failure; generating AIS cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.6INTEGER {oamVcOperStateAisState(0), oamVcOperStateRdiState(1), oamVcOperStateDownRetry(2), oamVcOperStateUpRetry(3), oamVcOperStateUp(4), oamVcOperStateDown(5), oamVcOperStateNotManaged(6), oamVcOperStateVpAis(7), oamVcOperStateVpRdi(8), oamVcOperStateVcInVpRdi(9), oamVcoperStateVcInVpAis(10), oamVcOperStateSegAis(11), oamVcOperStateSegRdi(12), oamVcOperStateGenAis(13)}read-onlycurrent
juniAtmCircuitOamLoopbackFrequency
OBJECT-TYPE
The OAM loopback frequency in seconds.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.7Integer32 (1..600)read-writecurrent
juniAtmCircuitInOamF5Cells
OBJECT-TYPE
Received OAM F5 cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.8Counter32read-onlycurrent
juniAtmCircuitInOamCellsDropped
OBJECT-TYPE
Received OAM cells that were dropped.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.9Counter32read-onlycurrent
juniAtmCircuitOutOamF5Cells
OBJECT-TYPE
Transmitted OAM F5 cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.10Counter32read-onlycurrent
juniAtmCircuitInOamF5EndToEndLoopbackCells
OBJECT-TYPE
Total received OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitInOamF5EndToEndLoopbackCmds and juniAtmCircuitInOamF5EndToEndLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.11Counter32read-onlycurrent
juniAtmCircuitInOamF5SegmentLoopbackCells
OBJECT-TYPE
Total received OAM F5 segment loopback cells. Aggregate of juniAtmCircuitInOamF5SegmentLoopbackCmds and juniAtmCircuitInOamF5SegmentLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.12Counter32read-onlycurrent
juniAtmCircuitInOamF5AisCells
OBJECT-TYPE
Received OAM F5 AIS cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.13Counter32read-onlycurrent
juniAtmCircuitInOamF5RdiCells
OBJECT-TYPE
Received OAM F5 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.14Counter32read-onlycurrent
juniAtmCircuitOutOamF5EndToEndLoopbackCells
OBJECT-TYPE
Total transmitted OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitOutOamF5EndToEndLoopbackCmds and juniAtmCircuitOutOamF5EndToEndLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.15Counter32read-onlycurrent
juniAtmCircuitOutOamF5SegmentLoopbackCells
OBJECT-TYPE
Total transmitted OAM F5 segment loopback cells. Aggregate of juniAtmCircuitOutOamF5SegmentLoopbackCmds and juniAtmCircuitOutOamF5SegmentLoopbackRsps
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.16Counter32read-onlycurrent
juniAtmCircuitOutOamF5RdiCells
OBJECT-TYPE
Transmitted OAM F5 RDI cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.17Counter32read-onlycurrent
juniAtmCircuitInOamF5EndToEndLoopbackCmds
OBJECT-TYPE
Received OAM F5 end-to-end loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.18Counter32read-onlycurrent
juniAtmCircuitInOamF5EndToEndLoopbackRsps
OBJECT-TYPE
Received OAM F5 end-to-end loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.19Counter32read-onlycurrent
juniAtmCircuitInOamF5SegmentLoopbackCmds
OBJECT-TYPE
Received OAM F5 segment loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.20Counter32read-onlycurrent
juniAtmCircuitInOamF5SegmentLoopbackRsps
OBJECT-TYPE
Received OAM F5 segment loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.21Counter32read-onlycurrent
juniAtmCircuitOutOamF5EndToEndLoopbackCmds
OBJECT-TYPE
Transmitted OAM F5 end-to-end loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.22Counter32read-onlycurrent
juniAtmCircuitOutOamF5EndToEndLoopbackRsps
OBJECT-TYPE
Transmitted OAM F5 end-to-end loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.23Counter32read-onlycurrent
juniAtmCircuitOutOamF5SegmentLoopbackCmds
OBJECT-TYPE
Transmitted OAM F5 segment loopback commands.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.24Counter32read-onlycurrent
juniAtmCircuitOutOamF5SegmentLoopbackRsps
OBJECT-TYPE
Transmitted OAM F5 segment loopback responses.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.25Counter32read-onlycurrent
juniAtmCircuitOamUpCount
OBJECT-TYPE
Specifies the number of successive loopback cell responses to receive before a PVC is up for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.26Integer32 (1..60)read-writecurrent
juniAtmCircuitOamDownCount
OBJECT-TYPE
Specifies the number of successive loopback cell responses not received before declaring a PVC down for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.27Integer32 (1..60)read-writecurrent
juniAtmCircuitOamRetryFrequency
OBJECT-TYPE
Specifies the frequency (in seconds) to transmit loopback cells when verifying PVC state (up or down) for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.28Integer32 (1..600)read-writecurrent
juniAtmCircuitOamAlarmDownCount
OBJECT-TYPE
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring a PVC down.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.29Integer32 (1..60)read-writecurrent
juniAtmCircuitOamAlarmClearTimeout
OBJECT-TYPE
Specifies how long to wait (in seconds) before declaring a PVC up after it has stopped receiving alarm cells.
1.3.6.1.4.1.4874.2.2.8.1.3.4.1.30Integer32 (3..60)read-writecurrent
juniAtmSubIfVccTrafficShapingTable
OBJECT-TYPE
This table contains entries for traffic shaping of ATM VCCs configured on ATM subinterfaces present in the system. This table augments the juniAtmSubIfVccTable only for VCCs that support traffic shapping. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
1.3.6.1.4.1.4874.2.2.8.1.3.5not-accessiblecurrent
juniAtmSubIfVccTrafficShapingEntry
OBJECT-TYPE
Each entry describes the traffic shping characteristics of an ATM subinterface VCC.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1not-accessiblecurrent
juniAtmSubIfVccTrafficShapingCdvt
OBJECT-TYPE
The network cell delay variation tolerance (CDVT) in tenths of a microsecond.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1.1Unsigned32read-createcurrent
juniAtmSubIfVccTrafficShapingClp0
OBJECT-TYPE
Specifies whether or not only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only for VBR circuits.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1.2TruthValueread-createcurrent
juniAtmSubIfVccTrafficShapingTagging
OBJECT-TYPE
Specifies whether or not CLP0 cells should be tagged for SCR policing (VBR.3 conformance). Applicable only for VBR circuits.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1.3TruthValueread-createcurrent
juniAtmSubIfVccTrafficShapingPoliceObserve
OBJECT-TYPE
Specifies whether of not no policing action is to be taken (note the double negative; if true(1) then no policing action will be taken; if false(2) then policing action will be taken). Regardless of the state of this object, all counters will be incremented.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1.4TruthValueread-createcurrent
juniAtmSubIfVccTrafficShapingPacketShaping
OBJECT-TYPE
Specifies whether of not to shape output traffic on a packet boundary.
1.3.6.1.4.1.4874.2.2.8.1.3.5.1.5TruthValueread-createcurrent
juniAtmSubIfSvcConfigTable
OBJECT-TYPE
This table contains entries for extending the juniAtmSubIfTable to configure switched virtual connection (SVC) on the subinterfaces.
1.3.6.1.4.1.4874.2.2.8.1.3.6not-accessibledeprecated
juniAtmSubIfSvcConfigEntry
OBJECT-TYPE
Each entry provides configuration parameters for an ATM SVC on the subinterface.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1not-accessibledeprecated
juniAtmSubIfSvcRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.1RowStatusread-createdeprecated
juniAtmSubIfSvcConfigDestAtmAddress
OBJECT-TYPE
Specifies the destination ATM NSAP address of the circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.2AtmAddr (SIZE(20))read-createdeprecated
juniAtmSubIfSvcConfigCircuitType
OBJECT-TYPE
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.3INTEGER {rfc1483VcMux(0), rfc1483Llc(1)}read-createdeprecated
juniAtmSubIfSvcConfigServiceCategory
OBJECT-TYPE
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.4INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)}read-createdeprecated
juniAtmSubIfSvcConfigPcr
OBJECT-TYPE
Peak Cell Rate, in kilo-bits per second (kbps), of this circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.5Unsigned32read-createdeprecated
juniAtmSubIfSvcConfigScr
OBJECT-TYPE
Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.6Unsigned32read-createdeprecated
juniAtmSubIfSvcConfigMbs
OBJECT-TYPE
Maximum Burst Size, in cells, of this circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.7Unsigned32read-createdeprecated
juniAtmSubIfSvcConfigCdvt
OBJECT-TYPE
Specify the network Cell Delay Variation Tolerance.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.8Unsigned32read-createobsolete
juniAtmSubIfSvcConfigClp0
OBJECT-TYPE
Specify that only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance).
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.9TruthValueread-createdeprecated
juniAtmSubIfSvcConfigTagging
OBJECT-TYPE
Specify that CLP0 cells should be tagged for SCR policing (VBR.3 conformance).
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.10TruthValueread-createdeprecated
juniAtmSubIfSvcConfigObserve
OBJECT-TYPE
Specify that no policing action is to be taken; only counters are incremented.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.11TruthValueread-createobsolete
juniAtmSubIfSvcConfigPacketDiscard
OBJECT-TYPE
Enable early packet Discard for this circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.12TruthValueread-createdeprecated
juniAtmSubIfSvcConfigDestE164Address
OBJECT-TYPE
Specifies the destination ATM E164 address of the circuit.
1.3.6.1.4.1.4874.2.2.8.1.3.6.1.13AtmAddr (SIZE(0 | 8))read-createobsolete
juniAtmSubIfDescriptionExport
OBJECT-TYPE
Enabling of this object will program the subinterface description down to the applicable line card. Note, the subinterface description sent down to the line card is a truncated version (32 bytes) of the ifAlias.
1.3.6.1.4.1.4874.2.2.8.1.3.7TruthValueread-writecurrent
juniAtmNbma
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.4
juniAtmNbmaMapTable
OBJECT-TYPE
This table contains entries for ATM NBMA maps.
1.3.6.1.4.1.4874.2.2.8.1.4.1not-accessiblecurrent
juniAtmNbmaMapEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM NBMA map.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1not-accessiblecurrent
juniAtmNbmaMapName
OBJECT-TYPE
The NBMA map name.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.1JuniAtmNbmaMapNamenot-accessiblecurrent
juniAtmNbmaMapVcd
OBJECT-TYPE
An integer identifier for the ATM circuit, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.2Integer32 (0..2147483647)not-accessiblecurrent
juniAtmNbmaMapIpAddress
OBJECT-TYPE
The IP address associated with this entry.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.3IpAddressread-createcurrent
juniAtmNbmaMapVpi
OBJECT-TYPE
The VPI identifier of the ATM circuit.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.4AtmVpIdentifierread-onlycurrent
juniAtmNbmaMapVci
OBJECT-TYPE
The VCI identifier of the ATM circuit.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.5AtmVcIdentifierread-onlycurrent
juniAtmNbmaMapIfIndex
OBJECT-TYPE
The ifIndex of the ATM major interface associated with this entry. The value of this object will be zero when the map is not applied to an interface.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.6InterfaceIndexOrZeroread-onlycurrent
juniAtmNbmaMapBroadcast
OBJECT-TYPE
The broadcast enable/disable setting for this entry. The value true(1) enable broadcast support; disable(2) disabled broadcast support for this entry.
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.7TruthValueread-createcurrent
juniAtmNbmaMapRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy Additional notes to aid the network manager: - NBMA maps are not supported on dynamic interface. - NBMA maps can only be applied to a single major ATM interface at a time. - NBMA maps cannot be deleted unless the map is removed from the ATM interface (juniAtmNbmaMapIfIndex = 0). - The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and juniAtmNbmaMapIfIndex are zero until the map is applied to a major ATM interface. - To create an entry in this table, the following objects must be present in the set PDU: juniAtmNbmaMapIpAddress juniAtmNbmaMapBroadcast juniAtmNbmaMapRowStatus - Once created, only the following objects can be modified: juniAtmNbmaMapBroadcast
1.3.6.1.4.1.4874.2.2.8.1.4.1.1.8RowStatusread-createcurrent
juniAtmNbmaMapListTable
OBJECT-TYPE
This table contains entries for ATM NBMA map lists.
1.3.6.1.4.1.4874.2.2.8.1.4.2not-accessiblecurrent
juniAtmNbmaMapListEntry
OBJECT-TYPE
Each entry describes the characteristics of an ATM NBMA map.
1.3.6.1.4.1.4874.2.2.8.1.4.2.1not-accessiblecurrent
juniAtmNbmaMapListName
OBJECT-TYPE
The NBMA Map List name.
1.3.6.1.4.1.4874.2.2.8.1.4.2.1.1JuniAtmNbmaMapNamenot-accessiblecurrent
juniAtmNbmaMapListRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
1.3.6.1.4.1.4874.2.2.8.1.4.2.1.2RowStatusread-createcurrent
juniAtmPing
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.5
juniAtmPingTestTypes
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.5.1
juniAtmPingTestOamSeg
OBJECT-IDENTITY
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using segment OAM cells. The test type must have appended to it a code that uniquely identifies an intermediate point responsible for looping back each cell. If this is absent, the loopbacks are performed at the end of the segment or connection. E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks should be performed at the intermediate point labeled 5.
1.3.6.1.4.1.4874.2.2.8.1.5.1.1current
juniAtmPingTestOamE2E
OBJECT-IDENTITY
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using end-to-end OAM cells.
1.3.6.1.4.1.4874.2.2.8.1.5.1.2current
juniAtmVpPingTable
OBJECT-TYPE
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VpTestTable to do ping (multiple loopback) type testing.
1.3.6.1.4.1.4874.2.2.8.1.5.2not-accessiblecurrent
juniAtmVpPingEntry
OBJECT-TYPE
Each entry describes the characteristics, status and results of the most recent ATM ping test.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1not-accessiblecurrent
juniAtmVpPingProbeCount
OBJECT-TYPE
The number of ping probes (OAM cells) to be sent to complete the test.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.1Unsigned32 (1..32)read-writecurrent
juniAtmVpPingTimeOut
OBJECT-TYPE
Specifies the time-out value, in seconds, for a remote ping operation.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.2Unsigned32 (1..5)read-writecurrent
juniAtmVpPingCtlTrapGeneration
OBJECT-TYPE
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.3Bits {testCompletion(0)}read-writecurrent
juniAtmVpPingSentProbes
OBJECT-TYPE
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.4Unsigned32read-onlycurrent
juniAtmVpPingProbeResponses
OBJECT-TYPE
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.5Unsigned32read-onlycurrent
juniAtmVpPingStartTime
OBJECT-TYPE
The time (sysUpTime) when the test started.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.6TimeStampread-onlycurrent
juniAtmVpPingMinRtt
OBJECT-TYPE
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.7Unsigned32read-onlycurrent
juniAtmVpPingMaxRtt
OBJECT-TYPE
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.8Unsigned32read-onlycurrent
juniAtmVpPingAverageRtt
OBJECT-TYPE
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.2.1.9Unsigned32read-onlycurrent
juniAtmVcPingTable
OBJECT-TYPE
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VcTestTable to do ping (multiple loopback) type testing.
1.3.6.1.4.1.4874.2.2.8.1.5.3not-accessiblecurrent
juniAtmVcPingEntry
OBJECT-TYPE
Each entry describes the characteristics, status and results of the most recent ATM ping test.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1not-accessiblecurrent
juniAtmVcPingProbeCount
OBJECT-TYPE
The number of ping probes (OAM cells) to be sent to complete the test.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.1Unsigned32 (1..32)read-writecurrent
juniAtmVcPingTimeOut
OBJECT-TYPE
Specifies the time-out value, in seconds, for a remote ping operation.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.2Unsigned32 (1..5)read-writecurrent
juniAtmVcPingCtlTrapGeneration
OBJECT-TYPE
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.3Bits {testCompletion(0)}read-writecurrent
juniAtmVcPingSentProbes
OBJECT-TYPE
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.4Unsigned32read-onlycurrent
juniAtmVcPingProbeResponses
OBJECT-TYPE
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.5Unsigned32read-onlycurrent
juniAtmVcPingStartTime
OBJECT-TYPE
The time (sysUpTime) when the test started.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.6TimeStampread-onlycurrent
juniAtmVcPingMinRtt
OBJECT-TYPE
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.7Unsigned32read-onlycurrent
juniAtmVcPingMaxRtt
OBJECT-TYPE
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.8Unsigned32read-onlycurrent
juniAtmVcPingAverageRtt
OBJECT-TYPE
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
1.3.6.1.4.1.4874.2.2.8.1.5.3.1.9Unsigned32read-onlycurrent
juniAtmPingTestCode
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.5.4
juniAtmPingTestCodeOamDisabled
OBJECT-IDENTITY
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the juniAtmIfOamCellRxAdminState is set to disabled.
1.3.6.1.4.1.4874.2.2.8.1.5.4.1current
juniAtmPingTestCodeCircuitDown
OBJECT-IDENTITY
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the operational status of the ATM circuit is down.
1.3.6.1.4.1.4874.2.2.8.1.5.4.2current
juniAtmPingTestCodeStopped
OBJECT-IDENTITY
This test code indicates that the ATM ping operation is administratively stopped by an External Management.
1.3.6.1.4.1.4874.2.2.8.1.5.4.3current
juniAtmPingTestCodeOamVcOperState
OBJECT-IDENTITY
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the circuit is down because of a OAM fault condition. This is possible if juniAtmCircuitVcOamOperStatus is one of the following: oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS. oamVcOperStateRdiState(1) - RDI cell received.
1.3.6.1.4.1.4874.2.2.8.1.5.4.4current
juniAtmPingTestCodeMaxPingCountReached
OBJECT-IDENTITY
This test code indicates that the ping operation cannot be initiated as the maximum number of ping possible on this interfaces exceeds the allowable limit.
1.3.6.1.4.1.4874.2.2.8.1.5.4.5current
juniAtmPingTestCodeInvalidParams
OBJECT-IDENTITY
This Test Code identities the Ping operation cannot be initiated as one or more of the Ping Parameters is Invalid.
1.3.6.1.4.1.4874.2.2.8.1.5.4.6current
juniAtmLocation
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.6
juniAtmSubIfLocationType
OBJECT-TYPE
Describes the interpretation of JuniInterfaceLocationValue object values into platform-dependent interface location components, e.g., 'slot.port' on an ERX.
1.3.6.1.4.1.4874.2.2.8.1.6.1JuniInterfaceLocationTyperead-onlycurrent
juniAtmSubIfLocationTable
OBJECT-TYPE
The entries in this table report the ifIndex of ATM Subinterfaces by location.
1.3.6.1.4.1.4874.2.2.8.1.6.2not-accessiblecurrent
juniAtmSubIfLocationEntry
OBJECT-TYPE
A specification of ATM subinterfaces by location.
1.3.6.1.4.1.4874.2.2.8.1.6.2.1not-accessiblecurrent
juniAtmSubIfLocationIndex
OBJECT-TYPE
The value of a platform interface location.
1.3.6.1.4.1.4874.2.2.8.1.6.2.1.1JuniInterfaceLocationValuenot-accessiblecurrent
juniAtmSubIfLocationIfIndex
OBJECT-TYPE
The ifIndex value of this subinterface.
1.3.6.1.4.1.4874.2.2.8.1.6.2.1.2InterfaceIndexread-onlycurrent
juniAtmVcClass
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.1.7
juniAtmVcClassNameTable
OBJECT-TYPE
The entries in this table provide mappings of ATM VC class names to local integer identifiers. These integers are used as indexes into other MIB tables containing ATM VC attributes associated with the same VC class name.
1.3.6.1.4.1.4874.2.2.8.1.7.1not-accessiblecurrent
juniAtmVcClassNameEntry
OBJECT-TYPE
A mapping of ATM VC class name to an integer identifier for the ATM VC class.
1.3.6.1.4.1.4874.2.2.8.1.7.1.1not-accessiblecurrent
juniAtmVcClassName
OBJECT-TYPE
The ATM VC class name uniquely identifying this entry.
1.3.6.1.4.1.4874.2.2.8.1.7.1.1.1DisplayString (SIZE(1..32))read-onlycurrent
juniAtmVcClassNameRowStatus
OBJECT-TYPE
Controls creation/deletion of entries in this table. Only the values 'createAndGo' ,'destroy', 'active' and 'notInService' may be SET. The SNMP manager would set the row status to notInService before making any VC class attribute changes explained in juniAtmVcClassTable. Once the VC class attribute changes are complete, the SNMP manager would set the row status to active, upon which the VC class attribute changes would be committed. Any ATM VC class attribute changes that are made when the row status is 'active' are committed right away.
1.3.6.1.4.1.4874.2.2.8.1.7.1.1.2RowStatusread-createcurrent
juniAtmVcClassNameId
OBJECT-TYPE
The integer identifier associated with this VC class name. The value of this identifier is assigned by the device when an entry in this table is created.
1.3.6.1.4.1.4874.2.2.8.1.7.1.1.3Unsigned32read-onlycurrent
juniAtmVcClassIdTable
OBJECT-TYPE
Provides inverse mapping of ATM VC class IDs to ATM VC class names.
1.3.6.1.4.1.4874.2.2.8.1.7.2not-accessiblecurrent
juniAtmVcClassIdEntry
OBJECT-TYPE
A mapping of an integer identifier to an ATM VC class name.
1.3.6.1.4.1.4874.2.2.8.1.7.2.1not-accessiblecurrent
juniAtmVcClassIdId
OBJECT-TYPE
The integer identifier associated with this ATM VC class name.
1.3.6.1.4.1.4874.2.2.8.1.7.2.1.1Unsigned32not-accessiblecurrent
juniAtmVcClassIdName
OBJECT-TYPE
The ATM VC class name having the associated identifier.
1.3.6.1.4.1.4874.2.2.8.1.7.2.1.2DisplayString (SIZE(1..32))read-onlycurrent
juniAtmVcClassTable
OBJECT-TYPE
This table contains Juniper ATM VC Class entries which can be used to specify the ATM PVC attributes either at creation or modification time. A row in this table with default values is created when an entry in juniAtmVcClassNameTable is created.
1.3.6.1.4.1.4874.2.2.8.1.7.3not-accessiblecurrent
juniAtmVcClassEntry
OBJECT-TYPE
Each entry contains the attributes of the ATM VC which would be applied to the VC either at creation or modification time when this ATM VC class is associated to it.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1not-accessiblecurrent
juniAtmVcClassId
OBJECT-TYPE
The integer identifier associated with this ATM VC class. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.1Unsigned32not-accessiblecurrent
juniAtmVcClassVccType
OBJECT-TYPE
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VC Mux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.2INTEGER {rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)}read-writecurrent
juniAtmVcClassVccServiceCategory
OBJECT-TYPE
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.3INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)}read-writecurrent
juniAtmVcClassVccPcr
OBJECT-TYPE
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.4Integer32 (0..2147483647)read-writecurrent
juniAtmVcClassVccScr
OBJECT-TYPE
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.5Integer32 (0..2147483647)read-writecurrent
juniAtmVcClassVccMbs
OBJECT-TYPE
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.6Integer32 (0..16777215)read-writecurrent
juniAtmVcClassVccOamAdminStatus
OBJECT-TYPE
The OAM VC integrity administrative state of the ATM VC associated with this class.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.7INTEGER {oamAdminStateDisabled(1), oamAdminStateEnabled(2)}read-writecurrent
juniAtmVcClassVccOamLoopbackFrequency
OBJECT-TYPE
The OAM loopback frequency in seconds.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.8Integer32 (1..600)read-writecurrent
juniAtmVcClassVccOamUpCount
OBJECT-TYPE
Specifies the number of successive loopback cell responses to receive before the ATM VC associated with this class is declared up for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.9Integer32 (1..60)read-writecurrent
juniAtmVcClassVccOamDownCount
OBJECT-TYPE
Specifies the number of successive loopback cell responses not received before declaring the ATM VC associated with this class as down for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.10Integer32 (1..60)read-writecurrent
juniAtmVcClassVccOamRetryFrequency
OBJECT-TYPE
Specifies the frequency (in seconds) to transmit loopback cells when verifying the ATM VC operational state associated with this class (up or down) for connectivity verification.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.11Integer32 (1..600)read-writecurrent
juniAtmVcClassVccOamAlarmDownCount
OBJECT-TYPE
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring the ATM VC associated with class as down.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.12Integer32 (1..60)read-writecurrent
juniAtmVcClassVccOamAlarmClearTimeout
OBJECT-TYPE
Specifies how long to wait (in seconds) before declaring the ATM VC associated with class as up after it has stopped receiving alarm cells.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.13Integer32 (3..60)read-writecurrent
juniAtmVcClassVccInverseArp
OBJECT-TYPE
Enables the inverse ARP protocol on the ATM VC associated with this class; true(1) enables the protocol, false(2) disables it.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.14TruthValueread-writecurrent
juniAtmVcClassVccInverseArpRefresh
OBJECT-TYPE
The refresh rate in minutes between inverse ARP protocol messages.
1.3.6.1.4.1.4874.2.2.8.1.7.3.1.15Integer32 (0..60)read-writecurrent
juniAtmTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.3
juniAtmTrapPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.3.0
juniAtmConformance
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.4
juniAtmCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.4.1
juniAtmGroups
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.8.4.2

Notifications

NameOIDStatus
juniAtmVpPingTestCompleted
NOTIFICATION-TYPE
Generated at the completion of a AtmfM4VpTest when the corresponding juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit set.
1.3.6.1.4.1.4874.2.2.8.3.0.1current
juniAtmVcPingTestCompleted
NOTIFICATION-TYPE
Generated at the completion of a AtmfM4VcTest when the corresponding juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit set.
1.3.6.1.4.1.4874.2.2.8.3.0.2current

Conformance

NameOIDStatus
juniAtmCompliance
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for NBMA map lists and ATM ping.
1.3.6.1.4.1.4874.2.2.8.4.1.1obsolete
juniAtmCompliance2
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for traffic shapping on VCC subinterfaces.
1.3.6.1.4.1.4874.2.2.8.4.1.2obsolete
juniAtmCompliance3
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for connection admission control (CAC).
1.3.6.1.4.1.4874.2.2.8.4.1.3obsolete
juniAtmCompliance4
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when ATM SVC, CAC used bandwidth and sub-interface address objects were added.
1.3.6.1.4.1.4874.2.2.8.4.1.4obsolete
juniAtmCompliance5
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when CAC recieve bandwith and E164 public addressing support was added.
1.3.6.1.4.1.4874.2.2.8.4.1.5obsolete
juniAtmCompliance6
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when F4 flow OAM circuit config and stats tables were added to the Juniper ATM MIB.
1.3.6.1.4.1.4874.2.2.8.4.1.6obsolete
juniAtmCompliance7
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when the juniAtmLocationGroup was added.
1.3.6.1.4.1.4874.2.2.8.4.1.7obsolete
juniAtmCompliance8
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added to export the subinterface description to the line cards.
1.3.6.1.4.1.4874.2.2.8.4.1.8obsolete
juniAtmCompliance9
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was added.
1.3.6.1.4.1.4874.2.2.8.4.1.9obsolete
juniAtmCompliance10
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion, juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were deprecated.
1.3.6.1.4.1.4874.2.2.8.4.1.10obsolete
juniAtmCompliance11
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmGroup8 was added.
1.3.6.1.4.1.4874.2.2.8.4.1.11obsolete
juniAtmCompliance12
MODULE-COMPLIANCE
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmVpStatsGroup was added.
1.3.6.1.4.1.4874.2.2.8.4.1.12obsolete
juniAtmCompliance13
MODULE-COMPLIANCE
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when SVC support was removed.
1.3.6.1.4.1.4874.2.2.8.4.1.13obsolete
juniAtmCompliance14
MODULE-COMPLIANCE
The compliance statement for entities which implement the Juniper ATM MIB.
1.3.6.1.4.1.4874.2.2.8.4.1.14current
juniAtmGroup
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when the juniAtmIfMapGroup object was added.
1.3.6.1.4.1.4874.2.2.8.4.2.1obsolete
juniAtmAal5Group
OBJECT-GROUP
A collection of objects providing management of AAL5 interfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.2current
juniAtmSubIfGroup
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfNbma, juniAtmSubIfInverseArp, and juniAtmSubIfInverseArpRefresh were added.
1.3.6.1.4.1.4874.2.2.8.4.2.3obsolete
juniAtmVpTunnelGroup
OBJECT-GROUP
A collection of objects providing management of VP tunnels in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.4current
juniAtmNbmaMapGroup
OBJECT-GROUP
A collection of object providing management of NBMA in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.5current
juniAtmSubIfGroup2
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfAddress was added.
1.3.6.1.4.1.4874.2.2.8.4.2.6obsolete
juniAtmVpPingControlGroup
OBJECT-GROUP
A collection of object providing management of ATM VPL Ping testing in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.7current
juniAtmVcPingControlGroup
OBJECT-GROUP
A collection of object providing management of ATM VCL Ping testing in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.8current
juniAtmPingTrapGroup
NOTIFICATION-GROUP
A collection of notifications supporting ATM Ping testing in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.9current
juniAtmGroup2
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC).
1.3.6.1.4.1.4874.2.2.8.4.2.10obsolete
juniAtmTrafficShapingGroup
OBJECT-GROUP
A collection of objects providing management of ATM traffic shaping in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.11current
juniAtmGroup3
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC) used bandwidth.
1.3.6.1.4.1.4874.2.2.8.4.2.12obsolete
juniAtmGroup4
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when CAC recieve bandwith and E164 public addressing objects were added.
1.3.6.1.4.1.4874.2.2.8.4.2.13obsolete
juniAtmSvcGroup
OBJECT-GROUP
Obsolete collection of objects providing management of ATM SVC interfaces in a Juniper product. This group became obsolete when E164 public addressing support was added.
1.3.6.1.4.1.4874.2.2.8.4.2.14obsolete
juniAtmSubIfGroup3
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfMtu was added.
1.3.6.1.4.1.4874.2.2.8.4.2.15obsolete
juniAtmGroup5
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when ATM VP description support was added.
1.3.6.1.4.1.4874.2.2.8.4.2.16obsolete
juniAtmSvcGroup2
OBJECT-GROUP
A collection of objects providing management of ATM SVC interfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.17current
juniAtmPnniGroup
OBJECT-GROUP
A collection of objects providing management of PNNI Routing Control Channels in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.18current
juniAtmSubIfGroup4
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when support was added to export the subinterface description to the line cards.
1.3.6.1.4.1.4874.2.2.8.4.2.19obsolete
juniAtmF4OamCircuitGroup
OBJECT-GROUP
Obsolete collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.20obsolete
juniAtmGroup6
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when bulk-configuration profile override support was added.
1.3.6.1.4.1.4874.2.2.8.4.2.21obsolete
juniAtmLocationGroup
OBJECT-GROUP
A collection of objects providing interface location information in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.22current
juniAtmSubIfGroup5
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.23obsolete
juniAtmMartiniGroup
OBJECT-GROUP
A collection of objects providing ATM Martini cell aggregation configuration.
1.3.6.1.4.1.4874.2.2.8.4.2.24current
juniAtmGroup7
OBJECT-GROUP
Obsolete collection of objects providing management of ATM interfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.25obsolete
juniAtmGroup8
OBJECT-GROUP
A collection of objects providing management of ATM interfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.26obsolete
juniAtmVpStatsGroup
OBJECT-GROUP
A collection of objects providing ATM VP level statistics.
1.3.6.1.4.1.4874.2.2.8.4.2.27current
juniAtmSubIfGroup6
OBJECT-GROUP
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when ATM SVC support was removed.
1.3.6.1.4.1.4874.2.2.8.4.2.28obsolete
juniAtmF4OamCircuitGroup2
OBJECT-GROUP
A collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.29current
juniAtmGroup9
OBJECT-GROUP
A collection of objects providing management of ATM interfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.30current
juniAtmSubIfGroup7
OBJECT-GROUP
A collection of objects providing management of ATM subinterfaces in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.31current
juniAtmVcClassGroup
OBJECT-GROUP
A collection of objects providing management of ATM VC class in a Juniper product.
1.3.6.1.4.1.4874.2.2.8.4.2.32current