Juniper-UNI-ATM-MIB
- Registered at
- 1.3.6.1.4.1.4874.2.2.8
- Last updated
- 2005-11-15 11:33
- Organization
- Juniper Networks, Inc.
- Revisions
- 2005-11-15 11:33, 2005-08-17 17:26, 2005-02-17 23:15, 2004-12-08 15:22, 2003-12-30 15:07, 2004-02-25 20:23, 2003-09-19 22:01, 2003-07-14 15:37, 2003-01-15 19:32, 2002-08-09 14:03, 2002-08-09 13:40, 2002-01-24 14:00, 2001-12-14 18:04, 2001-11-26 16:39, 2000-11-27 19:51, 2000-08-02 00:00, 2000-05-12 00:00, 2000-01-13 00:00, 1999-08-04 00:00
- Namespace
- juniper
- Source file
Juniper-UNI-ATM-MIB- Digest
sha256:56e7ca9ee339b748cbb9c9b9eae52577ff1c10b9499e5e7449d3a36f3f83baff
Description
The ATM MIB for the Juniper enterprise.
Contact
Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net
Imports
| From | Symbols |
|---|---|
| ATM-FORUM-SNMP-M4-MIB | atmfM4VcTestCode, atmfM4VcTestId, atmfM4VcTestObject, atmfM4VcTestResult, atmfM4VcTestType, atmfM4VpTestCode, atmfM4VpTestId, atmfM4VpTestObject, atmfM4VpTestResult, atmfM4VpTestType |
| ATM-MIB | atmVclVci, atmVclVpi, atmVplVpi |
| ATM-TC-MIB | AtmAddr, AtmVcIdentifier, AtmVorXAdminStatus, AtmVpIdentifier |
| IF-MIB | InterfaceIndex, InterfaceIndexOrZero, ifIndex |
| Juniper-MIBs | juniMibs |
| Juniper-TC | JuniEnable, JuniInterfaceLocationType, JuniInterfaceLocationValue, JuniNextIfIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ATM-FORUM-SNMP-M4-MIB ATM-MIB ATM-TC-MIB ENTITY-MIB HOST-RESOURCES-MIB IANA-ENTITY-MIB IANAifType-MIB IF-MIB Juniper-MIBs Juniper-TC Juniper-UNI-ATM-MIB Juniper-UNI-SMI SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| JuniAtmLocationType TEXTUAL-CONVENTION Obsolete description of the platform-dependent interpretation of a JuniAtmLocationValue object. This textual convention has been relpaced by Juniper-TC.JuniInterfaceLocationType. | obsolete | |||
| JuniAtmLocationValue TEXTUAL-CONVENTION Obsolete value of a platform-dependent interface location, represented as an OCTET STRING. A corresponding JuniAtmLocationType object identified the mapping of octets to location elements, e.g. 'slot.port'. This textual convention has been replaced by Juniper-TC.JuniInterfaceLocationValue. | obsolete | |||
| JuniAtmNbmaMapName TEXTUAL-CONVENTION An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system. | current | |||
| JuniAtmNbmaMapNameOrNull TEXTUAL-CONVENTION An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system. Differs from JuniAtmNbmaMapName in that it permits a zero-length string. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| juniAtmObjects OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1 | |||
| juniAtmIfLayer OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.1 | |||
| juniAtmNextIfIndex OBJECT-TYPE Coordinate ifIndex value allocation for entries in juniAtmIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. | 1.3.6.1.4.1.4874.2.2.8.1.1.1 | JuniNextIfIndex | read-only | current |
| juniAtmIfTable OBJECT-TYPE This table contains entries for ATM interfaces present in the system. | 1.3.6.1.4.1.4874.2.2.8.1.1.2 | not-accessible | current | |
| juniAtmIfEntry OBJECT-TYPE Each entry describes the characteristics of an ATM interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1 | not-accessible | current | |
| juniAtmIfIndex OBJECT-TYPE The ifIndex of the ATM interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmNextIfIndex. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmIfRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmIfRowStatus juniAtmIfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmIfIndex must have been determined previously, by reading juniAtmNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.2 | RowStatus | read-create | current |
| juniAtmIfLowerIfIndex OBJECT-TYPE The ifIndex of an interface over which this ATM interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.3 | InterfaceIndexOrZero | read-create | current |
| juniAtmIfIlmiVpi OBJECT-TYPE The VPI of the ILMI of a major ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.4 | AtmVpIdentifier | read-create | current |
| juniAtmIfIlmiVci OBJECT-TYPE The VCI of the ILMI of a major ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.5 | AtmVcIdentifier | read-create | current |
| juniAtmIfIlmiVcd OBJECT-TYPE An integer identifier for the ILMI, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.6 | Integer32 (0..2147483647) | read-create | current |
| juniAtmIfIlmiPollFrequency OBJECT-TYPE The amount of time in seconds between successive transmissions of ILMI messages on this interface for the purpose of detecting loss of ILMI connectivity. The distinguished value zero disables ILMI connectivity procedures on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.7 | Integer32 (0..65535) | read-create | current |
| juniAtmIfIlmiAdminState OBJECT-TYPE The administrative status of ILMI in the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.8 | INTEGER {disabled(0), enabled(1)} | read-create | current |
| juniAtmIfUniVersion OBJECT-TYPE Use to specify the User Network Interface (UNI) the router should use when ILMI link auto determination is unsuccesful or ILMI is disabled. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.9 | INTEGER {uniVersionAutoConfig(0), version3Dot0(1), version3Dot1(2), version4Dot0(3)} | read-create | current |
| juniAtmIfOamCellRxAdminState OBJECT-TYPE Use to specify the OAM Cell Receive Administrative state on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.10 | INTEGER {oamCellAdminStateDisabled(0), oamCellAdminStateEnabled(1)} | read-create | current |
| juniAtmIfInCells OBJECT-TYPE The total number of cells received on this major interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.11 | Counter64 | read-only | current |
| juniAtmIfOutCells OBJECT-TYPE The total number of cells transmitted on this major interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.12 | Counter64 | read-only | current |
| juniAtmIfVcCount OBJECT-TYPE The total number of circuits configured on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.13 | Integer32 (0..268431360) | read-only | current |
| juniAtmIfMapGroup OBJECT-TYPE The NBMA map group this interface is associated with. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.14 | JuniAtmNbmaMapNameOrNull | read-create | current |
| juniAtmIfCacAdminState OBJECT-TYPE The administrative staus of CAC on this ATM major interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.15 | JuniEnable | read-create | current |
| juniAtmIfCacUbrWeight OBJECT-TYPE The bandwidth associated with every UBR and UBR with PCR connection configured on the ATM major interface. This value is used for CAC computation. The units are kilo-bits per second (kbps). | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.16 | Integer32 (0..2147483647) | read-create | current |
| juniAtmIfCacSubscriptionBandwidth OBJECT-TYPE The subscribed bandwidth of the ATM major interface. If this value is not specified or set to 0, the effective port bandwidth is used. When a Get operation is performed the current effective bandwidth is returned. The units are kilo-bits per second (kbps). | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.17 | Integer32 (0..2147483647) | read-create | current |
| juniAtmIfCacAvailableBandwidth OBJECT-TYPE The available bandwidth in Tx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps). | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.18 | Integer32 (0..2147483647) | read-only | current |
| juniAtmIfCacAvailableBandwidthRx OBJECT-TYPE The available bandwidth in Rx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps). | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.19 | Integer32 (0..2147483647) | read-only | deprecated |
| juniAtmIfE164Autoconversion OBJECT-TYPE The status of E164 autoconversion feature in the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.20 | INTEGER {disabled(0), enabled(1)} | read-create | obsolete |
| juniAtmIfE164Gateway OBJECT-TYPE The status of E164 gateway feature in the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.21 | INTEGER {disabled(0), enabled(1)} | read-create | obsolete |
| juniAtmIfE164OneToOneAddrTrans OBJECT-TYPE The status of E164 one-to-one address translation feature in the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.22 | INTEGER {disabled(0), enabled(1)} | read-create | obsolete |
| juniAtmIfOamCellFilter OBJECT-TYPE The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards received OAM AIS and RDI cells. The value oamCellFilterAll discards all received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateEnabled, this object has no effect. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.23 | INTEGER {oamCellFilterAll(0), oamCellFilterAlarm(1)} | read-create | current |
| juniAtmIfCacUsedBandwidthUpper OBJECT-TYPE The most significant 32 bits of the CAC used bandwidth on the ATM major interface. The least significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthLower. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.24 | Unsigned32 | read-only | current |
| juniAtmIfCacUsedBandwidthLower OBJECT-TYPE The least significant 32 bits of the CAC used bandwidth on the ATM major interface. The most significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthUpper. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.25 | Unsigned32 | read-only | current |
| juniAtmIfAssociatedVcClassId OBJECT-TYPE The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.26 | Unsigned32 | read-create | current |
| juniAtmPvcStatisticsTable OBJECT-TYPE This table contains statistics for PVC entries. | 1.3.6.1.4.1.4874.2.2.8.1.1.3 | not-accessible | current | |
| juniAtmPvcStatisticsEntry OBJECT-TYPE Each entry provides statistics on an ATM PVC. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1 | not-accessible | current | |
| juniAtmPvcStatsIfIndex OBJECT-TYPE The ifIndex of the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmPvcStatsVpi OBJECT-TYPE The VPI of the ATM VCC used by this ATM interface and PVC. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.2 | AtmVpIdentifier | not-accessible | current |
| juniAtmPvcStatsVci OBJECT-TYPE The VCI of the ATM VCC used by this ATM interface and PVC. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.3 | AtmVcIdentifier | not-accessible | current |
| juniAtmPvcStatsInCells OBJECT-TYPE Received cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.4 | Counter64 | read-only | current |
| juniAtmPvcStatsInCellOctets OBJECT-TYPE Received cells octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.5 | Counter64 | read-only | current |
| juniAtmPvcStatsInPackets OBJECT-TYPE Received AAL PDUs. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.6 | Counter64 | read-only | current |
| juniAtmPvcStatsInPacketOctets OBJECT-TYPE Received AAL PDU octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.7 | Counter64 | read-only | current |
| juniAtmPvcStatsOutCells OBJECT-TYPE Transmitted cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.8 | Counter64 | read-only | current |
| juniAtmPvcStatsOutCellOctets OBJECT-TYPE Transmitted cell octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.9 | Counter64 | read-only | current |
| juniAtmPvcStatsOutPackets OBJECT-TYPE Transmitted AAL PDUs. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.10 | Counter64 | read-only | current |
| juniAtmPvcStatsOutPacketOctets OBJECT-TYPE Transmitted AAL PDU octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.11 | Counter64 | read-only | current |
| juniAtmPvcStatsInCellErrors OBJECT-TYPE Received cells dropped due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.12 | Counter32 | read-only | current |
| juniAtmPvcStatsinPacketErrors OBJECT-TYPE Received packets dropped due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.13 | Counter32 | read-only | current |
| juniAtmPvcStatsOutCellErrors OBJECT-TYPE Cells not transmitted due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.14 | Counter32 | read-only | current |
| juniAtmPvcStatsOutPacketErrors OBJECT-TYPE Packets not transmitted due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.15 | Counter32 | read-only | current |
| juniAtmPvcStatsInPacketDiscards OBJECT-TYPE Received packets w/o errors discarded. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.16 | Counter32 | read-only | current |
| juniAtmPvcStatsInPacketOctetDiscards OBJECT-TYPE Received bytes w/o errors discarded. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.17 | Counter32 | read-only | current |
| juniAtmPvcStatsInPacketUnknownProtocol OBJECT-TYPE Received packets that are discarded because the interface can not discern or is not configured to support this protocol. | 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.18 | Counter32 | read-only | current |
| juniAtmVpTunnelTable OBJECT-TYPE This table contains entries for ATM VP Tunnels present in the system. | 1.3.6.1.4.1.4874.2.2.8.1.1.4 | not-accessible | current | |
| juniAtmVpTunnelEntry OBJECT-TYPE Each entry describes the characteristics of an ATM VP Tunnel. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1 | not-accessible | current | |
| juniAtmVpTunnelIfIndex OBJECT-TYPE The ifIndex of the ATM interface. The value of this object is the same as the juniAtmIfIndex object in the juniAtmIfTable. Entries in this table cannot be created unless the underlying ATM interface entry is created first in the juniAtmIfTable. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmVpTunnelVpi OBJECT-TYPE The VPI value for this VP tunnel entry. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.2 | AtmVpIdentifier | not-accessible | current |
| juniAtmVpTunnelKbps OBJECT-TYPE The tunnel rate in kilobits per second (kbps) for this entry. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.3 | Integer32 (0..2147483647) | read-create | current |
| juniAtmVpTunnelRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmVpTunnelRowStatus juniAtmVpTunnelKbps In addition, when creating an entry the following condition must hold: A correponding juniAtmVpTunnelIfIndex value must have been created in the juniAtmIfTable previously. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.4 | RowStatus | read-create | current |
| juniAtmVpTunnelServiceCategory OBJECT-TYPE The ATM service category for the tunnel. | 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.5 | INTEGER {nrtVbr(1), cbr(2)} | read-create | current |
| juniAtmIfCapabilityTable OBJECT-TYPE This table contains entries for ATM interfaces present in the system. | 1.3.6.1.4.1.4874.2.2.8.1.1.5 | not-accessible | current | |
| juniAtmIfCapabilityEntry OBJECT-TYPE Each entry describes the capabilities of an ATM interface. A management client can use this table to determine differences in the configurable level of support across entries in this table. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1 | not-accessible | current | |
| juniAtmIfCapabilityIndex OBJECT-TYPE The ifIndex of the ATM interface. The value of this object is the same as juniAtmIfIndex in the juniAtmIfTable. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmIfCapabilityTrafficShaping OBJECT-TYPE Indicates whether traffic shaping is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.2 | TruthValue | read-only | current |
| juniAtmIfCapabilityOam OBJECT-TYPE Indicates whether OAM is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.3 | TruthValue | read-only | current |
| juniAtmIfCapabilityDefaultVcPerVp OBJECT-TYPE The default number of VCs per VP for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.4 | Integer32 (0..65536) | read-only | current |
| juniAtmIfCapabilityNumVpiVciBits OBJECT-TYPE The total range of bits used for constructing VPI/VCI identifiers for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.5 | Integer32 (8..28) | read-only | current |
| juniAtmIfCapabilityMaxVcd OBJECT-TYPE The maximum configurable value for a VCD on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.6 | Integer32 (0..2147483647) | read-only | current |
| juniAtmIfCapabilityMaxVpi OBJECT-TYPE The maximum configurable value for a VPI on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.7 | AtmVpIdentifier | read-only | current |
| juniAtmIfCapabilityMaxVci OBJECT-TYPE The maximum configurable value for a VCI on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.8 | AtmVcIdentifier | read-only | current |
| juniAtmIfCapabilityOamCellFilter OBJECT-TYPE Indicates whether OAM cell filter is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not. | 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.9 | TruthValue | read-only | current |
| juniAtmIfSvcSignallingTable OBJECT-TYPE This table contains entries for extending the juniAtmIfTable for configuring signalling information for switched virtual connection (SVC). | 1.3.6.1.4.1.4874.2.2.8.1.1.6 | not-accessible | deprecated | |
| juniAtmIfSvcSignallingEntry OBJECT-TYPE Each entry provides configuration parameters for ATM signalling on the interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.6.1 | not-accessible | deprecated | |
| juniAtmIfSvcSignallingVpi OBJECT-TYPE The VPI identifier of the ATM circuit used for signalling for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.1 | AtmVpIdentifier | read-write | deprecated |
| juniAtmIfSvcSignallingVci OBJECT-TYPE The VCI identifier of the ATM circuit used for signalling for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.2 | AtmVcIdentifier | read-write | deprecated |
| juniAtmIfSvcSignallingVcd OBJECT-TYPE An integer identifier for the ATM circuit used for signalling on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.3 | Integer32 (0..2147483647) | read-write | deprecated |
| juniAtmIfSvcSignallingAdminStatus OBJECT-TYPE The administrative status of signalling on the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.4 | AtmVorXAdminStatus | read-write | deprecated |
| juniAtmIfPnniRccTable OBJECT-TYPE This table contains entries for extending the juniAtmIfTable for configuring PNNI RCC information. | 1.3.6.1.4.1.4874.2.2.8.1.1.7 | not-accessible | obsolete | |
| juniAtmIfPnniRccEntry OBJECT-TYPE Each entry provides configuration parameters for PNNI RCC on the interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.7.1 | not-accessible | obsolete | |
| juniAtmIfPnniRccVpi OBJECT-TYPE The VPI identifier of the ATM circuit used for PNNI RCC on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.1 | AtmVpIdentifier | read-write | obsolete |
| juniAtmIfPnniRccVci OBJECT-TYPE The VCI identifier of the ATM circuit used for PNNI RCC on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.2 | AtmVcIdentifier | read-write | obsolete |
| juniAtmIfPnniRccVcd OBJECT-TYPE An integer identifier for the ATM circuit used for PNNI RCC on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.3 | Integer32 (0..2147483647) | read-write | obsolete |
| juniAtmIfPnniRccAdminStatus OBJECT-TYPE The administrative status of PNNI on the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.4 | AtmVorXAdminStatus | read-write | obsolete |
| juniAtmOamF4FlowEndToEndCfgTable OBJECT-TYPE This table contains entries for F4 OAM end-to-end flows configured. | 1.3.6.1.4.1.4874.2.2.8.1.1.8 | not-accessible | current | |
| juniAtmOamF4FlowEndToEndCfgEntry OBJECT-TYPE Each entry provides configuration parameters for one F4 OAM end-to-end flow configured for each VPI. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1 | not-accessible | current | |
| juniAtmOamF4FlowEndToEndIfIndex OBJECT-TYPE The ifIndex of the ATM interface to configure the F4 OAM end-to-end flow. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmOamF4FlowEndToEndVpi OBJECT-TYPE Select the VPI for F4 OAM end-to-end flow configuration. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.2 | Integer32 (0..255) | not-accessible | current |
| juniAtmOamF4FlowEndToEndLoopbackTimer OBJECT-TYPE Configure the timer for sending the F4 flow end-to-end loopback OAM cells. Setting this value will enable sending the F4 end cells on the circuit. It is not allowed to set the value to -1 and whenever it is read as -1 that means sending end loopback is not enabled. Setting the loopback timer, other than -1, will enable sending the end cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.3 | Integer32 (-1..600) | read-create | current |
| juniAtmOamF4FlowEndToEndCCSink OBJECT-TYPE Enable/Disable F4 flow end-to-end continuity check sink end point for this VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.4 | TruthValue | read-create | current |
| juniAtmOamF4FlowEndToEndCCSource OBJECT-TYPE Enable/Disable F4 flow end-to-end continuity check source end point for this VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.5 | TruthValue | read-create | current |
| juniAtmOamF4FlowEndToEndRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowEndToEndRowStatus F4 OAM end loopback and CC tests are mutually exclusive, enabling one will disable the other automatically. So, it is not allowed either at the circuit creation time or after the circuit creation to issue a request to enable end-to-end loopback and CC tests simultaneouly. Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous. | 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.6 | RowStatus | read-create | current |
| juniAtmOamF4FlowSegmentCfgTable OBJECT-TYPE This table contains entries for F4 OAM Segment flows configured. | 1.3.6.1.4.1.4874.2.2.8.1.1.9 | not-accessible | current | |
| juniAtmOamF4FlowSegmentCfgEntry OBJECT-TYPE Each entry provides configuration parameters for one F4 OAM Segment flow configured for each VPI. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1 | not-accessible | current | |
| juniAtmOamF4FlowSegmentIfIndex OBJECT-TYPE The ifIndex of the ATM interface to configure the F4 OAM segment flow. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmOamF4FlowSegmentVpi OBJECT-TYPE Select the VPI for F4 OAM segment flow configuration. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.2 | Integer32 (0..255) | not-accessible | current |
| juniAtmOamF4FlowSegmentCCSink OBJECT-TYPE Enable/Disable F4 flow segment continuity check sink end point for this VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.3 | TruthValue | read-create | current |
| juniAtmOamF4FlowSegmentCCSource OBJECT-TYPE Enable/Disable F4 flow segment continuity check source end point for this VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.4 | TruthValue | read-create | current |
| juniAtmOamF4FlowSegmentRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowSegmentRowStatus Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous. F4 OAM segment loopback test is not supported. | 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.5 | RowStatus | read-create | current |
| juniAtmVpDescrTable OBJECT-TYPE This table contains entries for ATM VP Description present in the system. The user can configure a description of up to 32 characters for every VP in the ATM interface. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created. | 1.3.6.1.4.1.4874.2.2.8.1.1.10 | not-accessible | current | |
| juniAtmVpDescrEntry OBJECT-TYPE Each entry contains the description of the VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.10.1 | not-accessible | current | |
| juniAtmVpDescription OBJECT-TYPE The description for this VP. The default value of this object is null string. | 1.3.6.1.4.1.4874.2.2.8.1.1.10.1.1 | SnmpAdminString (SIZE(0..32)) | read-write | current |
| juniAtmF4FlowOamEndToEndStatsTable OBJECT-TYPE This table contains entries for F4 flow EndToEnd OAM circuits stats. | 1.3.6.1.4.1.4874.2.2.8.1.1.11 | not-accessible | current | |
| juniAtmF4FlowOamEndToEndStatsEntry OBJECT-TYPE Each entry provides stats for one F4 OAM circuit for each VPI. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1 | not-accessible | current | |
| juniAtmF4FlowInOamEndAisCells OBJECT-TYPE Received end-to-end OAM F4 AIS cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.1 | Counter32 | read-only | current |
| juniAtmF4FlowInOamEndRdiCells OBJECT-TYPE Received end-to-end OAM F4 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.2 | Counter32 | read-only | current |
| juniAtmF4FlowInOamEndCCCells OBJECT-TYPE Received end-to-end OAM F4 CC cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.3 | Counter32 | read-only | current |
| juniAtmF4FlowInOamEndCCActDeActCells OBJECT-TYPE Received end-to-end OAM F4 activation/de-activation cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.4 | Counter32 | read-only | current |
| juniAtmF4FlowInOamEndLoopbackCells OBJECT-TYPE Total received OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndInLoopbackCmds and juniAtmF4FlowEndToEndInLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.5 | Counter32 | read-only | current |
| juniAtmF4FlowOutEndRdiCells OBJECT-TYPE Transmitted end-to-end OAM F4 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.6 | Counter32 | read-only | current |
| juniAtmF4FlowOutEndCCCells OBJECT-TYPE Transmitted end-to-end OAM F4 CC cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.7 | Counter32 | read-only | current |
| juniAtmF4FlowOutEndCCActDeActCells OBJECT-TYPE Transmitted end-to-end OAM F4 activation/de-activation cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.8 | Counter32 | read-only | current |
| juniAtmF4FlowOutEndToEndLoopbackCells OBJECT-TYPE Total transmitted OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndOutLoopbackCmds and juniAtmF4FlowEndToEndOutLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.9 | Counter32 | read-only | current |
| juniAtmF4FlowEndActualLoopbackFreq OBJECT-TYPE Actual end-to-end loopback Frequecy calculated for OAM cells transmission. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.10 | Integer32 (0..65535) | read-only | current |
| juniAtmF4FlowEndLastTimeChanged OBJECT-TYPE Last time end-to-end F4 OAM flow got changed. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.11 | TimeTicks | read-only | current |
| juniAtmF4FlowOamEndVpOperationState OBJECT-TYPE Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.12 | INTEGER {vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)} | read-only | current |
| juniAtmF4FlowOamEndVpAdminState OBJECT-TYPE End-to-end VP admin state. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.13 | INTEGER {down(0), up(1)} | read-only | current |
| juniAtmF4FlowEndInOamCells OBJECT-TYPE Received end-to-end OAM F4 loopback cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.14 | Counter32 | read-only | current |
| juniAtmF4FlowEndOutOamCells OBJECT-TYPE Transmitted end-to-end OAM F4 loopback cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.15 | Counter32 | read-only | current |
| juniAtmF4FlowEndInOamCellsDropped OBJECT-TYPE Received end-to-end OAM cells that were dropped. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.16 | Counter32 | read-only | current |
| juniAtmF4FlowEndToEndInLoopbackCmds OBJECT-TYPE Received OAM F4 end-to-end loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.17 | Counter32 | read-only | current |
| juniAtmF4FlowEndToEndInLoopbackRsps OBJECT-TYPE Received OAM F4 end-to-end loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.18 | Counter32 | read-only | current |
| juniAtmF4FlowEndToEndOutLoopbackCmds OBJECT-TYPE Transmitted OAM F4 end-to-end loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.19 | Counter32 | read-only | current |
| juniAtmF4FlowEndToEndOutLoopbackRsps OBJECT-TYPE Transmitted OAM F4 end-to-end loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.20 | Counter32 | read-only | current |
| juniAtmF4FlowOamSegmentStatsTable OBJECT-TYPE This table contains entries for F4 flow Segment OAM circuits stats. | 1.3.6.1.4.1.4874.2.2.8.1.1.12 | not-accessible | current | |
| juniAtmF4FlowOamSegmentStatsEntry OBJECT-TYPE Each entry provides stats for one F4 OAM circuit for each VPI. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1 | not-accessible | current | |
| juniAtmF4FlowInOamSegmentAisCells OBJECT-TYPE Received end-to-end OAM F4 AIS cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.1 | Counter32 | read-only | current |
| juniAtmF4FlowInOamSegmentRdiCells OBJECT-TYPE Received end-to-end OAM F4 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.2 | Counter32 | read-only | current |
| juniAtmF4FlowInOamSegmentCCCells OBJECT-TYPE Received end-to-end OAM F4 CC cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.3 | Counter32 | read-only | current |
| juniAtmF4FlowInOamSegmentCCActDeActCells OBJECT-TYPE Received end-to-end OAM F4 activation/de-activation cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.4 | Counter32 | read-only | current |
| juniAtmF4FlowInOamSegmentLoopbackCells OBJECT-TYPE Total received OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentInLoopbackCmds and juniAtmF4FlowSegmentInLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.5 | Counter32 | read-only | current |
| juniAtmF4FlowOutSegmentRdiCells OBJECT-TYPE Transmitted end-to-end OAM F4 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.6 | Counter32 | read-only | current |
| juniAtmF4FlowOutSegmentCCCells OBJECT-TYPE Transmitted end-to-end OAM F4 CC cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.7 | Counter32 | read-only | current |
| juniAtmF4FlowOutSegmentCCActDeActCells OBJECT-TYPE Transmitted end-to-end OAM F4 activation/de-activation cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.8 | Counter32 | read-only | current |
| juniAtmF4FlowOutSegmentLoopbackCells OBJECT-TYPE Total transmitted OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentOutLoopbackCmds and juniAtmF4FlowSegmentOutLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.9 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentLastTimeChanged OBJECT-TYPE Last time end-to-end F4 OAM flow got changed. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.10 | TimeTicks | read-only | current |
| juniAtmF4FlowOamSegmentVpOperationState OBJECT-TYPE Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.11 | INTEGER {vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)} | read-only | current |
| juniAtmF4FlowOamSegmentVpAdminState OBJECT-TYPE Segment VP admin state. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| juniAtmF4FlowSegmentInOamCells OBJECT-TYPE Received end-to-end OAM F4 loopback cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.13 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentOutOamCells OBJECT-TYPE Transmitted end-to-end OAM F4 loopback cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.14 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentInOamCellsDropped OBJECT-TYPE Received end-to-end OAM cells that were dropped. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.15 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentInLoopbackCmds OBJECT-TYPE Received OAM F4 segment loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.16 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentInLoopbackRsps OBJECT-TYPE Received OAM F4 segment loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.17 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentOutLoopbackCmds OBJECT-TYPE Transmitted OAM F4 segment loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.18 | Counter32 | read-only | current |
| juniAtmF4FlowSegmentOutLoopbackRsps OBJECT-TYPE Transmitted OAM F4 segment loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.19 | Counter32 | read-only | current |
| juniAtmMartiniTimeoutTimerTable OBJECT-TYPE This table contains entries for ATM Martini cell aggregation timeout detection. The user can configure timeout values for three timers. A row exists for every separate timer supported. These rows get created as soon as the ERX system comes up. | 1.3.6.1.4.1.4874.2.2.8.1.1.13 | not-accessible | current | |
| juniAtmMartiniTimeoutTimerEntry OBJECT-TYPE Each entry contains the timeout value of ATM Martini cell aggregation timer. | 1.3.6.1.4.1.4874.2.2.8.1.1.13.1 | not-accessible | current | |
| juniAtmMartiniTimeoutTimerIndex OBJECT-TYPE The ATM Martini cell aggregation timeout timer identifier. | 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.1 | INTEGER {timer1(1), timer2(2), timer3(3)} | not-accessible | current |
| juniAtmMartiniTimeoutTimerValue OBJECT-TYPE The ATM Martini cell aggregation timeout timer value in microseconds. | 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.2 | Integer32 (100..4095) | read-write | current |
| juniAtmVpStatsTable OBJECT-TYPE This table contains entries for ATM VP statistics present in the system. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created. | 1.3.6.1.4.1.4874.2.2.8.1.1.14 | not-accessible | current | |
| juniAtmVpStatsEntry OBJECT-TYPE Each entry contain the VP statistics. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1 | not-accessible | current | |
| juniAtmVpStatsIfIndex OBJECT-TYPE The ifIndex of the ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmVpStatsVpi OBJECT-TYPE The VPI value of the virtual path for which statistics are retrieved. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.2 | AtmVpIdentifier | not-accessible | current |
| juniAtmVpStatsInCells OBJECT-TYPE Received cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.3 | Counter64 | read-only | current |
| juniAtmVpStatsInPackets OBJECT-TYPE Received AAL5 PDUs. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.4 | Counter64 | read-only | current |
| juniAtmVpStatsInPacketOctets OBJECT-TYPE Received AAL5 PDU octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.5 | Counter64 | read-only | current |
| juniAtmVpStatsOutCells OBJECT-TYPE Transmitted cells. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.6 | Counter64 | read-only | current |
| juniAtmVpStatsOutPackets OBJECT-TYPE Transmitted AAL5 PDUs | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.7 | Counter64 | read-only | current |
| juniAtmVpStatsOutPacketOctets OBJECT-TYPE Transmitted AAL5 PDU octets. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.8 | Counter64 | read-only | current |
| juniAtmVpStatsInPacketErrors OBJECT-TYPE Received packets dropped due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.9 | Counter32 | read-only | current |
| juniAtmVpStatsOutPacketErrors OBJECT-TYPE Packets not transmitted due to errors. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.10 | Counter32 | read-only | current |
| juniAtmVpStatsInPacketDiscards OBJECT-TYPE Received packets without errors discarded. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.11 | Counter32 | read-only | current |
| juniAtmVpStatsInPacketOctetDiscards OBJECT-TYPE Received bytes without errors discarded. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.12 | Counter32 | read-only | current |
| juniAtmVpStatsInPacketUnknownProtocol OBJECT-TYPE Received packets that are discarded because the interface can not discern or is not configured to support this protocol. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.13 | Counter32 | read-only | current |
| juniAtmVpStatsCrcErrors OBJECT-TYPE Received packets that are discarded because of check sum erros | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.14 | Counter32 | read-only | current |
| juniAtmVpStatsSarTimeouts OBJECT-TYPE Received packets that are discarded because of SAR timeout | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.15 | Counter32 | read-only | current |
| juniAtmVpStatsOverSizedPackets OBJECT-TYPE Over sized packets that are received on this VP. | 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.16 | Counter32 | read-only | current |
| juniAtmAal5IfLayer OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.2 | |||
| juniAtmAal5NextIfIndex OBJECT-TYPE Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. | 1.3.6.1.4.1.4874.2.2.8.1.2.1 | JuniNextIfIndex | read-only | current |
| juniAtmAal5IfTable OBJECT-TYPE This table contains entries for ATM AAL5 interfaces present in the system. | 1.3.6.1.4.1.4874.2.2.8.1.2.2 | not-accessible | current | |
| juniAtmAal5IfEntry OBJECT-TYPE Each entry describes the characteristics of an ATM AAL5 interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable. | 1.3.6.1.4.1.4874.2.2.8.1.2.2.1 | not-accessible | current | |
| juniAtmAal5IfIndex OBJECT-TYPE The ifIndex of the ATM AAL5 interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmAal5NextIfIndex. | 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmAal5IfRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmAal5IfRowStatus juniAtmAal5IfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmAal5IfIndex must have been determined previously, by reading juniAtmAal5NextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table. | 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.2 | RowStatus | read-create | current |
| juniAtmAal5IfLowerIfIndex OBJECT-TYPE The ifIndex of an ATM interface over which this ATM AAL5 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation. | 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.3 | InterfaceIndexOrZero | read-create | current |
| juniAtmBulkCircuitsNameTable OBJECT-TYPE The entries in this table provide mappings of ATM bulk virtual circuit range names to local integer identifiers for those profiles. These integers are used as indexes into other MIB tables containing profile configuration parameters associated with the same profile name. | 1.3.6.1.4.1.4874.2.2.8.1.2.3 | not-accessible | current | |
| juniAtmBulkCircuitsNameEntry OBJECT-TYPE A mapping of a ATM bulk virtual circuit range name to an integer identifier for that name. | 1.3.6.1.4.1.4874.2.2.8.1.2.3.1 | not-accessible | current | |
| juniAtmBulkCircuitsNameAal5IfIndex OBJECT-TYPE The ifIndex of the ATM AAL5 interface. | 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmBulkCircuitsNameName OBJECT-TYPE The ATM bulk virtual circuit range name uniquely identifying this entry. | 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.2 | DisplayString (SIZE(1..80)) | not-accessible | current |
| juniAtmBulkCircuitsNameRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Creating an entry in this table creates corresponding entry in juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes corresponding entries in juniAtmBulkCircuitsIdTable, juniAtmBulkCircuitsTable and juniAtmProfileOverrideAssignIfCircuitTable. | 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.3 | RowStatus | read-create | current |
| juniAtmBulkCircuitsNameId OBJECT-TYPE The integer identifier associated with this ATM bulk virtual circuit range name. This value of this identifier is assigned by the device when an entry in this table is created. | 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.4 | Unsigned32 | read-only | current |
| juniAtmBulkCircuitsIdTable OBJECT-TYPE Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk virtual circuit names. | 1.3.6.1.4.1.4874.2.2.8.1.2.4 | not-accessible | current | |
| juniAtmBulkCircuitsIdEntry OBJECT-TYPE A mapping of an integer identifier to a ATM bulk virtual circuit name. | 1.3.6.1.4.1.4874.2.2.8.1.2.4.1 | not-accessible | current | |
| juniAtmBulkCircuitsIdAal5IfIndex OBJECT-TYPE The ifIndex of the ATM AAL5 interface. | 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmBulkCircuitsIdId OBJECT-TYPE The integer identifier associated with this ATM bulk virtual circuit name. | 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.2 | Unsigned32 | not-accessible | current |
| juniAtmBulkCircuitsIdName OBJECT-TYPE The ATM bulk virtual circuit name having the associated identifier. | 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.3 | DisplayString (SIZE(1..80)) | read-only | current |
| juniAtmBulkCircuitsIdNextInstance OBJECT-TYPE The next available instance value for juniAtmBulkCircuitsEntry. | 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.4 | Unsigned32 | read-only | current |
| juniAtmBulkCircuitsTable OBJECT-TYPE This table contains bulk virtual circuit range parameters. | 1.3.6.1.4.1.4874.2.2.8.1.2.5 | not-accessible | current | |
| juniAtmBulkCircuitsEntry OBJECT-TYPE Each entry describes the characteristics of VC range. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1 | not-accessible | current | |
| juniAtmBulkCircuitsAal5IfIndex OBJECT-TYPE The ifIndex of the ATM AAL5 interface on which this bulk virtual circuit sub-range is created. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmBulkCircuitsId OBJECT-TYPE The integer identifier associated with this ATM bulk virtual circuit name. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.2 | Unsigned32 | not-accessible | current |
| juniAtmBulkCircuitsInstance OBJECT-TYPE The unique identifier of the ATM bulk virtual circuit sub-range. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.3 | Unsigned32 | not-accessible | current |
| juniAtmBulkCircuitsRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since none of the VPI/VCI minimum and maximum values have default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI/VCI minimum and maximum values can only be configured upon creation. Deleting an entry in this table deletes corresponding entries in juniAtmProfileOverrideAssignIfCircuitTable. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4 | RowStatus | read-create | current |
| juniAtmBulkCircuitsMinVpi OBJECT-TYPE The minimum value of VPI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVpi. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.5 | AtmVpIdentifier | read-create | current |
| juniAtmBulkCircuitsMaxVpi OBJECT-TYPE The maximum value of VPI for this cicuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVpi. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.6 | AtmVpIdentifier | read-create | current |
| juniAtmBulkCircuitsMinVci OBJECT-TYPE The minimum value of VCI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVci. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.7 | AtmVcIdentifier | read-create | current |
| juniAtmBulkCircuitsMaxVci OBJECT-TYPE The maximum value of VCI for this circuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVci. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.8 | AtmVcIdentifier | read-create | current |
| juniAtmBulkCircuitsAdminState OBJECT-TYPE The administrative status of this circuit sub-range. | 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.9 | JuniEnable | read-create | current |
| juniAtmProfileOverrideAssignIfCircuitTable OBJECT-TYPE Table providing overriding profile assignment to a circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci. The entries in this table specify which profile to use when creating and configuring a dynamic interface above a circuit specified by vpi and vci. This entry is effective when the circuit specified by juniAtmProfileOverrideAssignIfCircuitAal5Index, juniAtmProfileOverrideAssignIfCircuitRangeId, juniAtmProfileOverrideAssignIfCircuitVpi, juniAtmProfileOverrideAssignIfCircuitVci is part of bulk-configuration. | 1.3.6.1.4.1.4874.2.2.8.1.2.6 | not-accessible | current | |
| juniAtmProfileOverrideAssignIfCircuitEntry OBJECT-TYPE An assignment of a profile to a circuit configured as part of bulk-configuration on an AAL5 interface. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1 | not-accessible | current | |
| juniAtmProfileOverrideAssignIfCircuitAal5Index OBJECT-TYPE The ifIndex of the AAL5 interface to which the profile is assigned. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmProfileOverrideAssignIfCircuitRangeId OBJECT-TYPE The integer identifier associated with the ATM bulk circuit configuration. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.2 | Unsigned32 | not-accessible | current |
| juniAtmProfileOverrideAssignIfCircuitVpi OBJECT-TYPE The VPI value of the circuit to which the profile is assigned. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.3 | AtmVpIdentifier | not-accessible | current |
| juniAtmProfileOverrideAssignIfCircuitVci OBJECT-TYPE The VCI value of the circuit to which the profile is assigned. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.4 | AtmVcIdentifier | not-accessible | current |
| juniAtmProfileOverrideAssignIfCircuitRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since the VPI, VCI and profileId values do not have any default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI, VCI and profileId values can only be configured upon creation. None of these values can be modified except by deleting the entry. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.5 | RowStatus | read-create | current |
| juniAtmProfileOverrideAssignIfCircuitProfileId OBJECT-TYPE The ID of the profile assigned to the circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.6 | Unsigned32 | read-create | current |
| juniAtmProfileOverrideAssignIfCircuitOperStatus OBJECT-TYPE The operational status of the profile override assignment identified by this entry. It returns inactive(0), if a static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will not be used to configure upper dynamic interfaces. It returns active(1), if no static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will be used to configure upper dynamic interfaces. | 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.7 | INTEGER {inactive(0), active(1)} | read-only | current |
| juniAtmSubIfLayer OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.3 | |||
| juniAtmSubIfNextIfIndex OBJECT-TYPE Coordinate ifIndex value allocation for entries in juniAtmSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. | 1.3.6.1.4.1.4874.2.2.8.1.3.1 | JuniNextIfIndex | read-only | current |
| juniAtmSubIfTable OBJECT-TYPE This table contains entries for ATM Subinterfaces present in the system. | 1.3.6.1.4.1.4874.2.2.8.1.3.2 | not-accessible | current | |
| juniAtmSubIfEntry OBJECT-TYPE Each entry describes the characteristics of an ATM Subinterface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1 | not-accessible | current | |
| juniAtmSubIfIndex OBJECT-TYPE The ifIndex of the ATM Subinterface. When creating entries in this table, suitable values for this object are determined by reading juniAtmSubNextIfIndex. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmSubIfRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfRowStatus juniAtmSubIfLowerIndex In addition, when creating an entry the following condition must hold: A value for juniAtmSubIfIndex must have been determined previously, by reading juniAtmSubIfNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.2 | RowStatus | read-create | current |
| juniAtmSubIfDistinguisher OBJECT-TYPE An integer identifier for the subinterface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among subinterfaces configured on the same underlying ATM adaptation layer. The upper bound for the value is further constrained to be identical with the maximum number of subinterfaces supported by the lower interface. If this object is not configured, a value will be allocated internally and can be queried after table entry creation has succeeded. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.3 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfLowerIfIndex OBJECT-TYPE The ifIndex of an ATM AAL5 interface over which this ATM subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.4 | InterfaceIndexOrZero | read-create | current |
| juniAtmSubIfNbma OBJECT-TYPE The NBMA administrative setting. Setting this value of this object to true(1) will enable multipoint access on this interface. Setting the value to false(2), will enable point to point access on this interface. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.5 | TruthValue | read-create | current |
| juniAtmSubIfAddress OBJECT-TYPE Specifies the local ATM NSAP address of the circuit. A GET operation returns a full 20-octet NSAP. A SET operation only requires 7 octets, since the prefix can be implied. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.6 | AtmAddr (SIZE(0 | 7 | 20)) | read-create | deprecated |
| juniAtmSubIfMtu OBJECT-TYPE The size of the largest packet which can be sent/received on the interface, specified in octets. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.7 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfAdvisoryRxSpeed OBJECT-TYPE Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for underlying circuit receive speed. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.8 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfMartiniMaxCellsPerPacket OBJECT-TYPE The number of cells that can be aggregated in a single ATM Martini packet in cell-relay mode. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.9 | Integer32 (1..190) | read-create | current |
| juniAtmSubIfMartiniTimeoutTimerId OBJECT-TYPE The timer identifier used to abandon cell aggregation when no cells are supplied for transmission in ATM Martini cell-relay mode. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.10 | Integer32 (1..3) | read-create | current |
| juniAtmSubIfAssociatedVcClassId OBJECT-TYPE The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface. | 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.11 | Unsigned32 | read-create | current |
| juniAtmSubIfVccTable OBJECT-TYPE This table contains entries for ATM VCCs configured on ATM subinterfaces present in the system. An implementation may constrain the number of VCCs permitted to be configured per ATM Subinterface; in particular, an implementation may restrict each ATM Subinterface to have a single VCC. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. | 1.3.6.1.4.1.4874.2.2.8.1.3.3 | not-accessible | current | |
| juniAtmSubIfVccEntry OBJECT-TYPE Each entry describes the characteristics of an ATM subinterface VCC. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1 | not-accessible | current | |
| juniAtmSubIfVccVpi OBJECT-TYPE The VPI of the ATM VCC used by this subinterface. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.1 | AtmVpIdentifier | not-accessible | current |
| juniAtmSubIfVccVci OBJECT-TYPE The VCI of the ATM VCC used by this subinterface. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.2 | AtmVcIdentifier | not-accessible | current |
| juniAtmSubIfVccRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfVccRowStatus In addition, when creating an entry the following conditions must hold: The ATM Subinterface identified by juniAtmSubIfIndex must exist. A positive value configured for juniAtmSubIfVccVcd must not already be assigned to an existing VCC. For each value of juniAtmSubIfVccServiceCategory, additional dependent objects in the entry require configuration as identified here: juniAtmSubIfVccServiceCategory Requires configuration of: ------------------------------------------------------------ ubr <none> ubrPcr juniAtmSubIfVccPcr nrtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs cbr juniAtmSubIfVccPcr rtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs ------------------------------------------------------------ Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.3 | RowStatus | read-create | current |
| juniAtmSubIfVccVcd OBJECT-TYPE An integer identifier for the circuit, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among VCCs configured on the same underlying ATM interface. If this object is not configured, or is configured with a value of zero, a value will be allocated internally and can be queried after table entry creation has succeeded. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.4 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfVccType OBJECT-TYPE Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VcMux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.5 | INTEGER {rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)} | read-create | current |
| juniAtmSubIfVccServiceCategory OBJECT-TYPE Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.6 | INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)} | read-create | current |
| juniAtmSubIfVccPcr OBJECT-TYPE Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.7 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfVccScr OBJECT-TYPE Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.8 | Integer32 (0..2147483647) | read-create | current |
| juniAtmSubIfVccMbs OBJECT-TYPE Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.9 | Integer32 (0..16777215) | read-create | current |
| juniAtmSubIfInverseArp OBJECT-TYPE Enables the inverse ARP protocol on this VCC; true(1) enables the protocol, false(2) disables it. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.10 | TruthValue | read-create | current |
| juniAtmSubIfInverseArpRefresh OBJECT-TYPE The refresh rate in minutes between inverse ARP protocol messages. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.11 | Integer32 (0..60) | read-create | current |
| juniAtmSubIfVccAssociatedVcClassId OBJECT-TYPE The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this VC. | 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.12 | Unsigned32 | read-create | current |
| juniAtmCircuitOamTable OBJECT-TYPE This table contains circuit OAM data for a PVC. | 1.3.6.1.4.1.4874.2.2.8.1.3.4 | not-accessible | current | |
| juniAtmCircuitOamEntry OBJECT-TYPE Each entry provides OAM data on an ATM PVC. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1 | not-accessible | current | |
| juniAtmCircuitOamIfIndex OBJECT-TYPE The ifIndex of the ATM subinterface. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.1 | InterfaceIndex | not-accessible | current |
| juniAtmCircuitOamVpi OBJECT-TYPE The VPI of the ATM VCC used by this ATM interface and PVC. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.2 | AtmVpIdentifier | not-accessible | current |
| juniAtmCircuitOamVci OBJECT-TYPE The VCI of the ATM VCC used by this ATM interface and PVC. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.3 | AtmVcIdentifier | not-accessible | current |
| juniAtmCircuitOamAdminStatus OBJECT-TYPE The administrative state of OAM for the interface identified by this entry. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.4 | INTEGER {oamAdminStateDisabled(1), oamAdminStateEnabled(2)} | read-write | current |
| juniAtmCircuitOamLoopbackOperStatus OBJECT-TYPE The operational status of OAM for the interface identified by this entry. oamOperStatusNotSupported(0) - OAM not supported on this interface oamOperStatusDisabled(1) - VC integrity disabled oamOperStatusSent(2) - Loopback sent, awaiting response oamOperStatusReceived(3) - Loopback response received, awaiting frequency oamOperStatusFailed(4) - Loopback response not received, or invalid response received | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.5 | INTEGER {oamOperStatusNotSupported(0), oamOperStatusDisabled(1), oamOperStatusSent(2), oamOperStatusReceived(3), oamOperStatusFailed(4)} | read-only | current |
| juniAtmCircuitVcOamOperStatus OBJECT-TYPE The OAM VC operational status of this entry. oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS oamVcOperStateRdiState(1) - RDI cell received oamVcOperStateDownRetry(2) - OAM loopback failed, using retry frequency to verify that the VC is really down oamVcOperStateUpRetry(3) - OAM loopback successful, using retry frequency to verify that the VC is really up oamVcOperStateUp(4) - OAM loopback successful after up retry verification oamVcOperStateDown(5) - OAM loopback failed after down retry verification oamVcOperStateNotManaged(6)- No verification via loopback cells being performed oamVcOperStateVpAis(7) - F4 AIS cell received oamVcOperStateVpRdi(8) - F4 RDI cell received oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure oamVcOperStateSegAis(11) - Segment AIS cell received oamVcOperStateSegRdi(12) - Segment RDI cell received oamVcOperStateGenAis(13) - Connection failure; generating AIS cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.6 | INTEGER {oamVcOperStateAisState(0), oamVcOperStateRdiState(1), oamVcOperStateDownRetry(2), oamVcOperStateUpRetry(3), oamVcOperStateUp(4), oamVcOperStateDown(5), oamVcOperStateNotManaged(6), oamVcOperStateVpAis(7), oamVcOperStateVpRdi(8), oamVcOperStateVcInVpRdi(9), oamVcoperStateVcInVpAis(10), oamVcOperStateSegAis(11), oamVcOperStateSegRdi(12), oamVcOperStateGenAis(13)} | read-only | current |
| juniAtmCircuitOamLoopbackFrequency OBJECT-TYPE The OAM loopback frequency in seconds. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.7 | Integer32 (1..600) | read-write | current |
| juniAtmCircuitInOamF5Cells OBJECT-TYPE Received OAM F5 cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.8 | Counter32 | read-only | current |
| juniAtmCircuitInOamCellsDropped OBJECT-TYPE Received OAM cells that were dropped. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.9 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5Cells OBJECT-TYPE Transmitted OAM F5 cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.10 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5EndToEndLoopbackCells OBJECT-TYPE Total received OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitInOamF5EndToEndLoopbackCmds and juniAtmCircuitInOamF5EndToEndLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.11 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5SegmentLoopbackCells OBJECT-TYPE Total received OAM F5 segment loopback cells. Aggregate of juniAtmCircuitInOamF5SegmentLoopbackCmds and juniAtmCircuitInOamF5SegmentLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.12 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5AisCells OBJECT-TYPE Received OAM F5 AIS cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.13 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5RdiCells OBJECT-TYPE Received OAM F5 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.14 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5EndToEndLoopbackCells OBJECT-TYPE Total transmitted OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitOutOamF5EndToEndLoopbackCmds and juniAtmCircuitOutOamF5EndToEndLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.15 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5SegmentLoopbackCells OBJECT-TYPE Total transmitted OAM F5 segment loopback cells. Aggregate of juniAtmCircuitOutOamF5SegmentLoopbackCmds and juniAtmCircuitOutOamF5SegmentLoopbackRsps | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.16 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5RdiCells OBJECT-TYPE Transmitted OAM F5 RDI cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.17 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5EndToEndLoopbackCmds OBJECT-TYPE Received OAM F5 end-to-end loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.18 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5EndToEndLoopbackRsps OBJECT-TYPE Received OAM F5 end-to-end loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.19 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5SegmentLoopbackCmds OBJECT-TYPE Received OAM F5 segment loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.20 | Counter32 | read-only | current |
| juniAtmCircuitInOamF5SegmentLoopbackRsps OBJECT-TYPE Received OAM F5 segment loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.21 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5EndToEndLoopbackCmds OBJECT-TYPE Transmitted OAM F5 end-to-end loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.22 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5EndToEndLoopbackRsps OBJECT-TYPE Transmitted OAM F5 end-to-end loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.23 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5SegmentLoopbackCmds OBJECT-TYPE Transmitted OAM F5 segment loopback commands. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.24 | Counter32 | read-only | current |
| juniAtmCircuitOutOamF5SegmentLoopbackRsps OBJECT-TYPE Transmitted OAM F5 segment loopback responses. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.25 | Counter32 | read-only | current |
| juniAtmCircuitOamUpCount OBJECT-TYPE Specifies the number of successive loopback cell responses to receive before a PVC is up for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.26 | Integer32 (1..60) | read-write | current |
| juniAtmCircuitOamDownCount OBJECT-TYPE Specifies the number of successive loopback cell responses not received before declaring a PVC down for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.27 | Integer32 (1..60) | read-write | current |
| juniAtmCircuitOamRetryFrequency OBJECT-TYPE Specifies the frequency (in seconds) to transmit loopback cells when verifying PVC state (up or down) for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.28 | Integer32 (1..600) | read-write | current |
| juniAtmCircuitOamAlarmDownCount OBJECT-TYPE Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring a PVC down. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.29 | Integer32 (1..60) | read-write | current |
| juniAtmCircuitOamAlarmClearTimeout OBJECT-TYPE Specifies how long to wait (in seconds) before declaring a PVC up after it has stopped receiving alarm cells. | 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.30 | Integer32 (3..60) | read-write | current |
| juniAtmSubIfVccTrafficShapingTable OBJECT-TYPE This table contains entries for traffic shaping of ATM VCCs configured on ATM subinterfaces present in the system. This table augments the juniAtmSubIfVccTable only for VCCs that support traffic shapping. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. | 1.3.6.1.4.1.4874.2.2.8.1.3.5 | not-accessible | current | |
| juniAtmSubIfVccTrafficShapingEntry OBJECT-TYPE Each entry describes the traffic shping characteristics of an ATM subinterface VCC. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1 | not-accessible | current | |
| juniAtmSubIfVccTrafficShapingCdvt OBJECT-TYPE The network cell delay variation tolerance (CDVT) in tenths of a microsecond. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.1 | Unsigned32 | read-create | current |
| juniAtmSubIfVccTrafficShapingClp0 OBJECT-TYPE Specifies whether or not only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only for VBR circuits. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.2 | TruthValue | read-create | current |
| juniAtmSubIfVccTrafficShapingTagging OBJECT-TYPE Specifies whether or not CLP0 cells should be tagged for SCR policing (VBR.3 conformance). Applicable only for VBR circuits. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.3 | TruthValue | read-create | current |
| juniAtmSubIfVccTrafficShapingPoliceObserve OBJECT-TYPE Specifies whether of not no policing action is to be taken (note the double negative; if true(1) then no policing action will be taken; if false(2) then policing action will be taken). Regardless of the state of this object, all counters will be incremented. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.4 | TruthValue | read-create | current |
| juniAtmSubIfVccTrafficShapingPacketShaping OBJECT-TYPE Specifies whether of not to shape output traffic on a packet boundary. | 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.5 | TruthValue | read-create | current |
| juniAtmSubIfSvcConfigTable OBJECT-TYPE This table contains entries for extending the juniAtmSubIfTable to configure switched virtual connection (SVC) on the subinterfaces. | 1.3.6.1.4.1.4874.2.2.8.1.3.6 | not-accessible | deprecated | |
| juniAtmSubIfSvcConfigEntry OBJECT-TYPE Each entry provides configuration parameters for an ATM SVC on the subinterface. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1 | not-accessible | deprecated | |
| juniAtmSubIfSvcRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.1 | RowStatus | read-create | deprecated |
| juniAtmSubIfSvcConfigDestAtmAddress OBJECT-TYPE Specifies the destination ATM NSAP address of the circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.2 | AtmAddr (SIZE(20)) | read-create | deprecated |
| juniAtmSubIfSvcConfigCircuitType OBJECT-TYPE Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.3 | INTEGER {rfc1483VcMux(0), rfc1483Llc(1)} | read-create | deprecated |
| juniAtmSubIfSvcConfigServiceCategory OBJECT-TYPE Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.4 | INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)} | read-create | deprecated |
| juniAtmSubIfSvcConfigPcr OBJECT-TYPE Peak Cell Rate, in kilo-bits per second (kbps), of this circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.5 | Unsigned32 | read-create | deprecated |
| juniAtmSubIfSvcConfigScr OBJECT-TYPE Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.6 | Unsigned32 | read-create | deprecated |
| juniAtmSubIfSvcConfigMbs OBJECT-TYPE Maximum Burst Size, in cells, of this circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.7 | Unsigned32 | read-create | deprecated |
| juniAtmSubIfSvcConfigCdvt OBJECT-TYPE Specify the network Cell Delay Variation Tolerance. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.8 | Unsigned32 | read-create | obsolete |
| juniAtmSubIfSvcConfigClp0 OBJECT-TYPE Specify that only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance). | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.9 | TruthValue | read-create | deprecated |
| juniAtmSubIfSvcConfigTagging OBJECT-TYPE Specify that CLP0 cells should be tagged for SCR policing (VBR.3 conformance). | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.10 | TruthValue | read-create | deprecated |
| juniAtmSubIfSvcConfigObserve OBJECT-TYPE Specify that no policing action is to be taken; only counters are incremented. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.11 | TruthValue | read-create | obsolete |
| juniAtmSubIfSvcConfigPacketDiscard OBJECT-TYPE Enable early packet Discard for this circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.12 | TruthValue | read-create | deprecated |
| juniAtmSubIfSvcConfigDestE164Address OBJECT-TYPE Specifies the destination ATM E164 address of the circuit. | 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.13 | AtmAddr (SIZE(0 | 8)) | read-create | obsolete |
| juniAtmSubIfDescriptionExport OBJECT-TYPE Enabling of this object will program the subinterface description down to the applicable line card. Note, the subinterface description sent down to the line card is a truncated version (32 bytes) of the ifAlias. | 1.3.6.1.4.1.4874.2.2.8.1.3.7 | TruthValue | read-write | current |
| juniAtmNbma OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.4 | |||
| juniAtmNbmaMapTable OBJECT-TYPE This table contains entries for ATM NBMA maps. | 1.3.6.1.4.1.4874.2.2.8.1.4.1 | not-accessible | current | |
| juniAtmNbmaMapEntry OBJECT-TYPE Each entry describes the characteristics of an ATM NBMA map. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1 | not-accessible | current | |
| juniAtmNbmaMapName OBJECT-TYPE The NBMA map name. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.1 | JuniAtmNbmaMapName | not-accessible | current |
| juniAtmNbmaMapVcd OBJECT-TYPE An integer identifier for the ATM circuit, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.2 | Integer32 (0..2147483647) | not-accessible | current |
| juniAtmNbmaMapIpAddress OBJECT-TYPE The IP address associated with this entry. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.3 | IpAddress | read-create | current |
| juniAtmNbmaMapVpi OBJECT-TYPE The VPI identifier of the ATM circuit. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.4 | AtmVpIdentifier | read-only | current |
| juniAtmNbmaMapVci OBJECT-TYPE The VCI identifier of the ATM circuit. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.5 | AtmVcIdentifier | read-only | current |
| juniAtmNbmaMapIfIndex OBJECT-TYPE The ifIndex of the ATM major interface associated with this entry. The value of this object will be zero when the map is not applied to an interface. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.6 | InterfaceIndexOrZero | read-only | current |
| juniAtmNbmaMapBroadcast OBJECT-TYPE The broadcast enable/disable setting for this entry. The value true(1) enable broadcast support; disable(2) disabled broadcast support for this entry. | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.7 | TruthValue | read-create | current |
| juniAtmNbmaMapRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy Additional notes to aid the network manager: - NBMA maps are not supported on dynamic interface. - NBMA maps can only be applied to a single major ATM interface at a time. - NBMA maps cannot be deleted unless the map is removed from the ATM interface (juniAtmNbmaMapIfIndex = 0). - The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and juniAtmNbmaMapIfIndex are zero until the map is applied to a major ATM interface. - To create an entry in this table, the following objects must be present in the set PDU: juniAtmNbmaMapIpAddress juniAtmNbmaMapBroadcast juniAtmNbmaMapRowStatus - Once created, only the following objects can be modified: juniAtmNbmaMapBroadcast | 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.8 | RowStatus | read-create | current |
| juniAtmNbmaMapListTable OBJECT-TYPE This table contains entries for ATM NBMA map lists. | 1.3.6.1.4.1.4874.2.2.8.1.4.2 | not-accessible | current | |
| juniAtmNbmaMapListEntry OBJECT-TYPE Each entry describes the characteristics of an ATM NBMA map. | 1.3.6.1.4.1.4874.2.2.8.1.4.2.1 | not-accessible | current | |
| juniAtmNbmaMapListName OBJECT-TYPE The NBMA Map List name. | 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.1 | JuniAtmNbmaMapName | not-accessible | current |
| juniAtmNbmaMapListRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy | 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.2 | RowStatus | read-create | current |
| juniAtmPing OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.5 | |||
| juniAtmPingTestTypes OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.5.1 | |||
| juniAtmPingTestOamSeg OBJECT-IDENTITY This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using segment OAM cells. The test type must have appended to it a code that uniquely identifies an intermediate point responsible for looping back each cell. If this is absent, the loopbacks are performed at the end of the segment or connection. E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks should be performed at the intermediate point labeled 5. | 1.3.6.1.4.1.4874.2.2.8.1.5.1.1 | current | ||
| juniAtmPingTestOamE2E OBJECT-IDENTITY This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using end-to-end OAM cells. | 1.3.6.1.4.1.4874.2.2.8.1.5.1.2 | current | ||
| juniAtmVpPingTable OBJECT-TYPE This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VpTestTable to do ping (multiple loopback) type testing. | 1.3.6.1.4.1.4874.2.2.8.1.5.2 | not-accessible | current | |
| juniAtmVpPingEntry OBJECT-TYPE Each entry describes the characteristics, status and results of the most recent ATM ping test. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1 | not-accessible | current | |
| juniAtmVpPingProbeCount OBJECT-TYPE The number of ping probes (OAM cells) to be sent to complete the test. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.1 | Unsigned32 (1..32) | read-write | current |
| juniAtmVpPingTimeOut OBJECT-TYPE Specifies the time-out value, in seconds, for a remote ping operation. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.2 | Unsigned32 (1..5) | read-write | current |
| juniAtmVpPingCtlTrapGeneration OBJECT-TYPE The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.3 | Bits {testCompletion(0)} | read-write | current |
| juniAtmVpPingSentProbes OBJECT-TYPE The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.4 | Unsigned32 | read-only | current |
| juniAtmVpPingProbeResponses OBJECT-TYPE The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.5 | Unsigned32 | read-only | current |
| juniAtmVpPingStartTime OBJECT-TYPE The time (sysUpTime) when the test started. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.6 | TimeStamp | read-only | current |
| juniAtmVpPingMinRtt OBJECT-TYPE The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.7 | Unsigned32 | read-only | current |
| juniAtmVpPingMaxRtt OBJECT-TYPE The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.8 | Unsigned32 | read-only | current |
| juniAtmVpPingAverageRtt OBJECT-TYPE The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.9 | Unsigned32 | read-only | current |
| juniAtmVcPingTable OBJECT-TYPE This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VcTestTable to do ping (multiple loopback) type testing. | 1.3.6.1.4.1.4874.2.2.8.1.5.3 | not-accessible | current | |
| juniAtmVcPingEntry OBJECT-TYPE Each entry describes the characteristics, status and results of the most recent ATM ping test. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1 | not-accessible | current | |
| juniAtmVcPingProbeCount OBJECT-TYPE The number of ping probes (OAM cells) to be sent to complete the test. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.1 | Unsigned32 (1..32) | read-write | current |
| juniAtmVcPingTimeOut OBJECT-TYPE Specifies the time-out value, in seconds, for a remote ping operation. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.2 | Unsigned32 (1..5) | read-write | current |
| juniAtmVcPingCtlTrapGeneration OBJECT-TYPE The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.3 | Bits {testCompletion(0)} | read-write | current |
| juniAtmVcPingSentProbes OBJECT-TYPE The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.4 | Unsigned32 | read-only | current |
| juniAtmVcPingProbeResponses OBJECT-TYPE The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.5 | Unsigned32 | read-only | current |
| juniAtmVcPingStartTime OBJECT-TYPE The time (sysUpTime) when the test started. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.6 | TimeStamp | read-only | current |
| juniAtmVcPingMinRtt OBJECT-TYPE The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.7 | Unsigned32 | read-only | current |
| juniAtmVcPingMaxRtt OBJECT-TYPE The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.8 | Unsigned32 | read-only | current |
| juniAtmVcPingAverageRtt OBJECT-TYPE The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test. | 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.9 | Unsigned32 | read-only | current |
| juniAtmPingTestCode OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.5.4 | |||
| juniAtmPingTestCodeOamDisabled OBJECT-IDENTITY This test code indicates that the ATM ping operation cannot be initiated or is aborted because the juniAtmIfOamCellRxAdminState is set to disabled. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.1 | current | ||
| juniAtmPingTestCodeCircuitDown OBJECT-IDENTITY This test code indicates that the ATM ping operation cannot be initiated or is aborted because the operational status of the ATM circuit is down. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.2 | current | ||
| juniAtmPingTestCodeStopped OBJECT-IDENTITY This test code indicates that the ATM ping operation is administratively stopped by an External Management. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.3 | current | ||
| juniAtmPingTestCodeOamVcOperState OBJECT-IDENTITY This test code indicates that the ATM ping operation cannot be initiated or is aborted because the circuit is down because of a OAM fault condition. This is possible if juniAtmCircuitVcOamOperStatus is one of the following: oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS. oamVcOperStateRdiState(1) - RDI cell received. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.4 | current | ||
| juniAtmPingTestCodeMaxPingCountReached OBJECT-IDENTITY This test code indicates that the ping operation cannot be initiated as the maximum number of ping possible on this interfaces exceeds the allowable limit. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.5 | current | ||
| juniAtmPingTestCodeInvalidParams OBJECT-IDENTITY This Test Code identities the Ping operation cannot be initiated as one or more of the Ping Parameters is Invalid. | 1.3.6.1.4.1.4874.2.2.8.1.5.4.6 | current | ||
| juniAtmLocation OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.6 | |||
| juniAtmSubIfLocationType OBJECT-TYPE Describes the interpretation of JuniInterfaceLocationValue object values into platform-dependent interface location components, e.g., 'slot.port' on an ERX. | 1.3.6.1.4.1.4874.2.2.8.1.6.1 | JuniInterfaceLocationType | read-only | current |
| juniAtmSubIfLocationTable OBJECT-TYPE The entries in this table report the ifIndex of ATM Subinterfaces by location. | 1.3.6.1.4.1.4874.2.2.8.1.6.2 | not-accessible | current | |
| juniAtmSubIfLocationEntry OBJECT-TYPE A specification of ATM subinterfaces by location. | 1.3.6.1.4.1.4874.2.2.8.1.6.2.1 | not-accessible | current | |
| juniAtmSubIfLocationIndex OBJECT-TYPE The value of a platform interface location. | 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.1 | JuniInterfaceLocationValue | not-accessible | current |
| juniAtmSubIfLocationIfIndex OBJECT-TYPE The ifIndex value of this subinterface. | 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.2 | InterfaceIndex | read-only | current |
| juniAtmVcClass OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.1.7 | |||
| juniAtmVcClassNameTable OBJECT-TYPE The entries in this table provide mappings of ATM VC class names to local integer identifiers. These integers are used as indexes into other MIB tables containing ATM VC attributes associated with the same VC class name. | 1.3.6.1.4.1.4874.2.2.8.1.7.1 | not-accessible | current | |
| juniAtmVcClassNameEntry OBJECT-TYPE A mapping of ATM VC class name to an integer identifier for the ATM VC class. | 1.3.6.1.4.1.4874.2.2.8.1.7.1.1 | not-accessible | current | |
| juniAtmVcClassName OBJECT-TYPE The ATM VC class name uniquely identifying this entry. | 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.1 | DisplayString (SIZE(1..32)) | read-only | current |
| juniAtmVcClassNameRowStatus OBJECT-TYPE Controls creation/deletion of entries in this table. Only the values 'createAndGo' ,'destroy', 'active' and 'notInService' may be SET. The SNMP manager would set the row status to notInService before making any VC class attribute changes explained in juniAtmVcClassTable. Once the VC class attribute changes are complete, the SNMP manager would set the row status to active, upon which the VC class attribute changes would be committed. Any ATM VC class attribute changes that are made when the row status is 'active' are committed right away. | 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.2 | RowStatus | read-create | current |
| juniAtmVcClassNameId OBJECT-TYPE The integer identifier associated with this VC class name. The value of this identifier is assigned by the device when an entry in this table is created. | 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.3 | Unsigned32 | read-only | current |
| juniAtmVcClassIdTable OBJECT-TYPE Provides inverse mapping of ATM VC class IDs to ATM VC class names. | 1.3.6.1.4.1.4874.2.2.8.1.7.2 | not-accessible | current | |
| juniAtmVcClassIdEntry OBJECT-TYPE A mapping of an integer identifier to an ATM VC class name. | 1.3.6.1.4.1.4874.2.2.8.1.7.2.1 | not-accessible | current | |
| juniAtmVcClassIdId OBJECT-TYPE The integer identifier associated with this ATM VC class name. | 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.1 | Unsigned32 | not-accessible | current |
| juniAtmVcClassIdName OBJECT-TYPE The ATM VC class name having the associated identifier. | 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.2 | DisplayString (SIZE(1..32)) | read-only | current |
| juniAtmVcClassTable OBJECT-TYPE This table contains Juniper ATM VC Class entries which can be used to specify the ATM PVC attributes either at creation or modification time. A row in this table with default values is created when an entry in juniAtmVcClassNameTable is created. | 1.3.6.1.4.1.4874.2.2.8.1.7.3 | not-accessible | current | |
| juniAtmVcClassEntry OBJECT-TYPE Each entry contains the attributes of the ATM VC which would be applied to the VC either at creation or modification time when this ATM VC class is associated to it. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1 | not-accessible | current | |
| juniAtmVcClassId OBJECT-TYPE The integer identifier associated with this ATM VC class. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.1 | Unsigned32 | not-accessible | current |
| juniAtmVcClassVccType OBJECT-TYPE Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VC Mux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.2 | INTEGER {rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)} | read-write | current |
| juniAtmVcClassVccServiceCategory OBJECT-TYPE Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.3 | INTEGER {ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)} | read-write | current |
| juniAtmVcClassVccPcr OBJECT-TYPE Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.4 | Integer32 (0..2147483647) | read-write | current |
| juniAtmVcClassVccScr OBJECT-TYPE Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.5 | Integer32 (0..2147483647) | read-write | current |
| juniAtmVcClassVccMbs OBJECT-TYPE Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.6 | Integer32 (0..16777215) | read-write | current |
| juniAtmVcClassVccOamAdminStatus OBJECT-TYPE The OAM VC integrity administrative state of the ATM VC associated with this class. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.7 | INTEGER {oamAdminStateDisabled(1), oamAdminStateEnabled(2)} | read-write | current |
| juniAtmVcClassVccOamLoopbackFrequency OBJECT-TYPE The OAM loopback frequency in seconds. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.8 | Integer32 (1..600) | read-write | current |
| juniAtmVcClassVccOamUpCount OBJECT-TYPE Specifies the number of successive loopback cell responses to receive before the ATM VC associated with this class is declared up for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.9 | Integer32 (1..60) | read-write | current |
| juniAtmVcClassVccOamDownCount OBJECT-TYPE Specifies the number of successive loopback cell responses not received before declaring the ATM VC associated with this class as down for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.10 | Integer32 (1..60) | read-write | current |
| juniAtmVcClassVccOamRetryFrequency OBJECT-TYPE Specifies the frequency (in seconds) to transmit loopback cells when verifying the ATM VC operational state associated with this class (up or down) for connectivity verification. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.11 | Integer32 (1..600) | read-write | current |
| juniAtmVcClassVccOamAlarmDownCount OBJECT-TYPE Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring the ATM VC associated with class as down. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.12 | Integer32 (1..60) | read-write | current |
| juniAtmVcClassVccOamAlarmClearTimeout OBJECT-TYPE Specifies how long to wait (in seconds) before declaring the ATM VC associated with class as up after it has stopped receiving alarm cells. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.13 | Integer32 (3..60) | read-write | current |
| juniAtmVcClassVccInverseArp OBJECT-TYPE Enables the inverse ARP protocol on the ATM VC associated with this class; true(1) enables the protocol, false(2) disables it. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.14 | TruthValue | read-write | current |
| juniAtmVcClassVccInverseArpRefresh OBJECT-TYPE The refresh rate in minutes between inverse ARP protocol messages. | 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.15 | Integer32 (0..60) | read-write | current |
| juniAtmTraps OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.3 | |||
| juniAtmTrapPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.3.0 | |||
| juniAtmConformance OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.4 | |||
| juniAtmCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.4.1 | |||
| juniAtmGroups OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.8.4.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| juniAtmVpPingTestCompleted NOTIFICATION-TYPE Generated at the completion of a AtmfM4VpTest when the corresponding juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit set. | 1.3.6.1.4.1.4874.2.2.8.3.0.1 | current |
| juniAtmVcPingTestCompleted NOTIFICATION-TYPE Generated at the completion of a AtmfM4VcTest when the corresponding juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit set. | 1.3.6.1.4.1.4874.2.2.8.3.0.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| juniAtmCompliance MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for NBMA map lists and ATM ping. | 1.3.6.1.4.1.4874.2.2.8.4.1.1 | obsolete |
| juniAtmCompliance2 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for traffic shapping on VCC subinterfaces. | 1.3.6.1.4.1.4874.2.2.8.4.1.2 | obsolete |
| juniAtmCompliance3 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for connection admission control (CAC). | 1.3.6.1.4.1.4874.2.2.8.4.1.3 | obsolete |
| juniAtmCompliance4 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when ATM SVC, CAC used bandwidth and sub-interface address objects were added. | 1.3.6.1.4.1.4874.2.2.8.4.1.4 | obsolete |
| juniAtmCompliance5 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when CAC recieve bandwith and E164 public addressing support was added. | 1.3.6.1.4.1.4874.2.2.8.4.1.5 | obsolete |
| juniAtmCompliance6 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when F4 flow OAM circuit config and stats tables were added to the Juniper ATM MIB. | 1.3.6.1.4.1.4874.2.2.8.4.1.6 | obsolete |
| juniAtmCompliance7 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when the juniAtmLocationGroup was added. | 1.3.6.1.4.1.4874.2.2.8.4.1.7 | obsolete |
| juniAtmCompliance8 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added to export the subinterface description to the line cards. | 1.3.6.1.4.1.4874.2.2.8.4.1.8 | obsolete |
| juniAtmCompliance9 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was added. | 1.3.6.1.4.1.4874.2.2.8.4.1.9 | obsolete |
| juniAtmCompliance10 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion, juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were deprecated. | 1.3.6.1.4.1.4874.2.2.8.4.1.10 | obsolete |
| juniAtmCompliance11 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmGroup8 was added. | 1.3.6.1.4.1.4874.2.2.8.4.1.11 | obsolete |
| juniAtmCompliance12 MODULE-COMPLIANCE The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmVpStatsGroup was added. | 1.3.6.1.4.1.4874.2.2.8.4.1.12 | obsolete |
| juniAtmCompliance13 MODULE-COMPLIANCE The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when SVC support was removed. | 1.3.6.1.4.1.4874.2.2.8.4.1.13 | obsolete |
| juniAtmCompliance14 MODULE-COMPLIANCE The compliance statement for entities which implement the Juniper ATM MIB. | 1.3.6.1.4.1.4874.2.2.8.4.1.14 | current |
| juniAtmGroup OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when the juniAtmIfMapGroup object was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.1 | obsolete |
| juniAtmAal5Group OBJECT-GROUP A collection of objects providing management of AAL5 interfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.2 | current |
| juniAtmSubIfGroup OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfNbma, juniAtmSubIfInverseArp, and juniAtmSubIfInverseArpRefresh were added. | 1.3.6.1.4.1.4874.2.2.8.4.2.3 | obsolete |
| juniAtmVpTunnelGroup OBJECT-GROUP A collection of objects providing management of VP tunnels in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.4 | current |
| juniAtmNbmaMapGroup OBJECT-GROUP A collection of object providing management of NBMA in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.5 | current |
| juniAtmSubIfGroup2 OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfAddress was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.6 | obsolete |
| juniAtmVpPingControlGroup OBJECT-GROUP A collection of object providing management of ATM VPL Ping testing in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.7 | current |
| juniAtmVcPingControlGroup OBJECT-GROUP A collection of object providing management of ATM VCL Ping testing in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.8 | current |
| juniAtmPingTrapGroup NOTIFICATION-GROUP A collection of notifications supporting ATM Ping testing in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.9 | current |
| juniAtmGroup2 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC). | 1.3.6.1.4.1.4874.2.2.8.4.2.10 | obsolete |
| juniAtmTrafficShapingGroup OBJECT-GROUP A collection of objects providing management of ATM traffic shaping in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.11 | current |
| juniAtmGroup3 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC) used bandwidth. | 1.3.6.1.4.1.4874.2.2.8.4.2.12 | obsolete |
| juniAtmGroup4 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when CAC recieve bandwith and E164 public addressing objects were added. | 1.3.6.1.4.1.4874.2.2.8.4.2.13 | obsolete |
| juniAtmSvcGroup OBJECT-GROUP Obsolete collection of objects providing management of ATM SVC interfaces in a Juniper product. This group became obsolete when E164 public addressing support was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.14 | obsolete |
| juniAtmSubIfGroup3 OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfMtu was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.15 | obsolete |
| juniAtmGroup5 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when ATM VP description support was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.16 | obsolete |
| juniAtmSvcGroup2 OBJECT-GROUP A collection of objects providing management of ATM SVC interfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.17 | current |
| juniAtmPnniGroup OBJECT-GROUP A collection of objects providing management of PNNI Routing Control Channels in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.18 | current |
| juniAtmSubIfGroup4 OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when support was added to export the subinterface description to the line cards. | 1.3.6.1.4.1.4874.2.2.8.4.2.19 | obsolete |
| juniAtmF4OamCircuitGroup OBJECT-GROUP Obsolete collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.20 | obsolete |
| juniAtmGroup6 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when bulk-configuration profile override support was added. | 1.3.6.1.4.1.4874.2.2.8.4.2.21 | obsolete |
| juniAtmLocationGroup OBJECT-GROUP A collection of objects providing interface location information in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.22 | current |
| juniAtmSubIfGroup5 OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.23 | obsolete |
| juniAtmMartiniGroup OBJECT-GROUP A collection of objects providing ATM Martini cell aggregation configuration. | 1.3.6.1.4.1.4874.2.2.8.4.2.24 | current |
| juniAtmGroup7 OBJECT-GROUP Obsolete collection of objects providing management of ATM interfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.25 | obsolete |
| juniAtmGroup8 OBJECT-GROUP A collection of objects providing management of ATM interfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.26 | obsolete |
| juniAtmVpStatsGroup OBJECT-GROUP A collection of objects providing ATM VP level statistics. | 1.3.6.1.4.1.4874.2.2.8.4.2.27 | current |
| juniAtmSubIfGroup6 OBJECT-GROUP Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when ATM SVC support was removed. | 1.3.6.1.4.1.4874.2.2.8.4.2.28 | obsolete |
| juniAtmF4OamCircuitGroup2 OBJECT-GROUP A collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.29 | current |
| juniAtmGroup9 OBJECT-GROUP A collection of objects providing management of ATM interfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.30 | current |
| juniAtmSubIfGroup7 OBJECT-GROUP A collection of objects providing management of ATM subinterfaces in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.31 | current |
| juniAtmVcClassGroup OBJECT-GROUP A collection of objects providing management of ATM VC class in a Juniper product. | 1.3.6.1.4.1.4874.2.2.8.4.2.32 | current |