HUAWEI-ENTITY-TRAP-MIB
- Registered at
- 1.3.6.1.4.1.2011.5.25.219
- Last updated
- 2018-12-13 00:00
- Organization
- Huawei Technologies Co.,Ltd.
- Revisions
- 2018-12-13 00:00, 2018-12-04 00:00, 2018-11-30 00:00, 2018-11-28 00:00, 2018-11-23 00:00, 2018-11-08 00:00, 2018-11-06 00:00, 2018-11-05 00:00, 2018-10-08 16:30, 2018-09-12 16:30, 2018-07-02 16:30, 2018-06-05 20:00, 2018-05-19 20:00, 2018-05-08 20:00, 2018-04-20 20:00, 2018-04-20 00:00, 2018-03-29 00:00, 2018-03-20 00:00, 2018-03-14 00:00, 2018-01-15 00:00, 2017-12-29 00:00, 2017-12-28 00:00, 2017-12-26 00:00, 2017-12-20 00:00, 2017-12-06 00:00, 2017-12-01 00:00, 2017-11-30 00:00, 2017-11-14 00:00, 2017-11-04 00:00, 2017-09-26 00:00, 2017-09-26 00:00, 2017-09-21 00:00, 2017-09-01 00:00, 2017-08-13 00:00, 2017-07-24 00:00, 2017-07-13 00:00, 2017-06-14 00:00, 2017-06-14 00:00, 2017-06-07 00:00, 2017-06-05 00:00, 2017-06-02 00:00, 2017-02-28 00:00, 2017-02-23 00:00, 2017-02-21 19:00, 2017-02-13 09:00, 2017-02-10 00:00, 2016-12-23 21:00, 2016-11-28 21:00, 2016-11-23 21:00, 2016-10-25 21:00, 2016-10-21 14:00, 2016-08-17 14:00, 2016-08-03 14:00, 2016-07-22 10:00, 2016-07-15 10:00, 2016-07-12 10:00, 2016-07-04 10:00, 2016-04-15 10:00, 2016-04-14 10:00, 2016-04-11 10:00, 2016-03-03 10:00, 2016-03-01 00:00, 2016-02-29 00:00, 2016-02-18 00:00, 2016-01-04 00:00, 2015-12-29 00:00, 2015-12-16 00:00, 2015-11-03 00:00, 2015-10-10 00:00, 2015-09-30 00:00, 2015-09-17 00:00, 2015-06-16 00:00, 2015-05-21 00:00, 2015-05-16 00:00, 2015-05-15 00:00, 2015-03-13 00:00, 2015-01-28 00:00, 2014-12-10 00:00, 2014-12-01 00:00, 2014-10-28 00:00, 2014-10-13 00:00, 2014-10-09 00:00, 2014-09-01 00:00, 2014-06-28 00:00, 2014-05-19 00:00, 2014-05-19 00:00, 2014-03-28 00:00, 2014-01-04 00:00, 2013-11-21 11:11, 2013-07-04 17:05, 2013-07-02 16:21, 2013-06-25 14:11, 2013-06-07 11:07, 2013-05-28 00:00, 2013-04-13 14:52, 2013-03-18 14:21, 2012-01-25 00:00
- Namespace
- huawei
- Source file
HUAWEI-ENTITY-TRAP-MIB- Digest
sha256:b2950bef0985a8b09ca8c3aceb4adc58251c8dd9c7bd5d64aa665dd098bc68d5
Description
This is the base trap definition for DataCom.
Contact
Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com
Imports
| From | Symbols |
|---|---|
| ENTITY-MIB | entPhysicalIndex, entPhysicalName |
| HUAWEI-BASE-TRAP-MIB | hwBaseTrapEventType, hwBaseTrapProbableCause, hwBaseTrapSeverity |
| HUAWEI-ENTITY-EXTENT-MIB | hwEntityOperStatus |
| HUAWEI-GTL-MIB | hwGtlItemIndex, hwGtlItemName |
| HUAWEI-MIB | hwDatacomm |
| IANA-ITU-ALARM-TC-MIB | IANAItuProbableCause |
| IF-MIB | ifAdminStatus, ifIndex, ifName, ifOperStatus |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB ENTITY-MIB HUAWEI-BASE-TRAP-MIB HUAWEI-ENTITY-EXTENT-MIB HUAWEI-ENTITY-TRAP-MIB HUAWEI-FLASH-MAN-MIB HUAWEI-GTL-MIB HUAWEI-MIB HUAWEI-SECURITY-STAT-MIB IANA-ENTITY-MIB IANA-ITU-ALARM-TC-MIB IANAifType-MIB IF-MIB ITU-ALARM-TC-MIB P-BRIDGE-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| HWTrapProbableCause TEXTUAL-CONVENTION This list contains the root reasons of the Huawei proprietary traps. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hwEntityTrapObject OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.1 | |||
| hwEntityPhysicalIndex OBJECT-TYPE The index of physical. | 1.3.6.1.4.1.2011.5.25.219.1.1 | Integer32 | read-write | current |
| hwEntityTrapEntType OBJECT-TYPE The entity type. | 1.3.6.1.4.1.2011.5.25.219.1.2 | INTEGER {mpu(1), lpu(2), sfu(3), pic(4), cfcard(5), ofc(6)} | read-write | current |
| hwEntityTrapFaultID OBJECT-TYPE To describe the fault id of trap. | 1.3.6.1.4.1.2011.5.25.219.1.3 | HWTrapProbableCause | accessible-for-notify | current |
| hwEntityCommunicateType OBJECT-TYPE The communicate type. | 1.3.6.1.4.1.2011.5.25.219.1.4 | INTEGER {controlChannel(1), monitorChannel(2), clockChannel(3), dataChannel(4)} | read-write | current |
| hwEntityThresholdTable OBJECT-TYPE A table to config the threshold of each sensor. | 1.3.6.1.4.1.2011.5.25.219.1.5 | not-accessible | current | |
| hwEntityThresholdEntry OBJECT-TYPE The entry of threshold table. | 1.3.6.1.4.1.2011.5.25.219.1.5.1 | not-accessible | current | |
| hwEntityThresholdType OBJECT-TYPE The abnormal type for temperature, voltage, humidity...... | 1.3.6.1.4.1.2011.5.25.219.1.5.1.1 | INTEGER {riseOver(1), fallBelow(2)} | read-only | current |
| hwEntityThresholdValue OBJECT-TYPE The threshold value of temperature, humidity ,fog ...... | 1.3.6.1.4.1.2011.5.25.219.1.5.1.2 | Integer32 | read-write | current |
| hwEntityThresholdCurrent OBJECT-TYPE The current value that been measured. | 1.3.6.1.4.1.2011.5.25.219.1.5.1.3 | Integer32 | read-only | current |
| hwEntityThresholdCritical OBJECT-TYPE The critical alarm threshold for critical alarm. It could be used for a more dangerous instance than hwEntityThresholdCritical. | 1.3.6.1.4.1.2011.5.25.219.1.5.1.4 | Integer32 | read-write | current |
| hwEntityThresholdWarning OBJECT-TYPE The warning alarm threshold for warning alarm. It could be used for a more dangerous instance than hwEntityThresholdWarning. | 1.3.6.1.4.1.2011.5.25.219.1.5.1.5 | Integer32 | read-write | current |
| hwUserDefAlarmName OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.5.25.219.1.6 | OCTET STRING | read-only | current |
| hwUserDefChannel OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.5.25.219.1.7 | Integer32 | read-write | current |
| hwSoftwareVersion OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.5.25.219.1.8 | OCTET STRING | accessible-for-notify | current |
| hwStartupSoftwareFileName OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.5.25.219.1.9 | OCTET STRING | accessible-for-notify | current |
| hwStorageDevName OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.5.25.219.1.10 | OCTET STRING | accessible-for-notify | current |
| hwPortDownReason OBJECT-TYPE AUAIS: The RX detects administrative(A) unit(U) alarm(A) indication(I) signal(S). B1TCA: The RX detects b1(B1) threshold(T) crossing(C) alarm(A). B2TCA: The RX detects b2(B2) threshold(T) crossing(C) alarm(A). B3TCA: The RX detects b3(B3) threshold(T) crossing(C) alarm(A). LAIS: The RX detects line(L) alarm(A) indication(I) signal(S). LCD: The RX detects loss(L) of code-group(C) delineation(D). LOF: The RX detects loss(L) of(O) frame(F). LOM: The RX detects loss(L) of(O) multiframe(M). LOP: The RX detects loss(L) of(O) pointer(M). LOS: The RX detects loss(L) of(O) signal(S). LRDI: The RX detects line(L) remote(R) defect(D) indication(I). LREI: The RX detects line(L) remote(R) error(D) indication(I). OOF: The RX detects out(O) of(O) frame(F). PAIS: The RX detects path(P) alarm(A) indication(I) signal(S). PPLM: The RX detects path(P) payload(P) label(L) mismatch(M). PRDI: The RX detects path(P) remote(R) defect(D) indication(I). PREI: The RX detects path(P) remote(R) error(E) indication(I). PUNEQ: The RX detects path(P) unequipped(UNEQ). RDOOL: The RX detects receive(R) data(D) out(O) of(O) lock(L). RROOL: The RX detects receive(R) reference(R) out(O) of(O) lock(L). SD: The RX detects signal(S) degrade(D). SF: The RX detects signal(S) fail(F). TROOL: The TX detects transmit(T) reference(R) out(O) of(O) lock(L). WLINK: The RX detects pcs link has failed (wis mode). TRANSCEIVER_OFFLINE: The transceiver is not in position. TRANSCEIVER_FAIL: A hardware failure occurs when accessing the transceiver. TRANSCEIVER_MISMATCH: The transceiver does not match the port-mode. TRANSCEIVER_UNKNOWN: The transceiver is unknown type. PMA_LOS: The PMA(physical medium attachment) detects loss of signal. PMA_UNLOCK: The PMA(physical medium attachment) detects receive data out of lock. PCS_HIGHBER: The PCS(physical coding sublayer) enter High-BER status. PCS_UNLOCK: The PCS(physical coding sublayer) detects receive data out of lock. LOCAL_FAULT: The RX detects Local Fault signal. REMOTE_FAULT: The RX detects Remote Fault signal. NEGOTIATION_FAIL: Auto-negotiation is not successful. SOFT_FORCE_DOWN: The interface was DOWN triggered by a protocol module or was administratively shut down. GPON_ACTIVATE_FAIL: The GPON optical module failed to be detected or activated. GPON_AUTHEN_LOID_FAIL: The authentication failed because the GPON optical module does not have an LOID. GPON_AUTHEN_PASSWORD_FAIL: The authentication failed because the password is incorrect. GPON_AUTHEN_LOIDCOLLI_FAIL: The authentication failed due to LODI collision of GPON optical modules. GPON_FIBER_LINKFAULT_FAIL: The optical link failed due to link disconnection or low optical receive power. GPON_TRANSCEIVERSHUT_FAIL: The transmitter of the GPON optical module was turned off on the OLT. GPON_ABNORMALSHINE_FAIL: The GPON optical module detected light emitting abnormalities, and the transmitter was turned off. GPON_TRANSCEIVERABNORMAL: Laser is in fault state. GPON_OTHER_ALARM: The GPON optical module has other fault. | 1.3.6.1.4.1.2011.5.25.219.1.11 | OCTET STRING | accessible-for-notify | current |
| hwEntityTrapRelativeResource OBJECT-TYPE MAC address. | 1.3.6.1.4.1.2011.5.25.219.1.12 | MacAddress | accessible-for-notify | current |
| hwEntityTrapReasonDescr OBJECT-TYPE Description of trap reason. | 1.3.6.1.4.1.2011.5.25.219.1.13 | OCTET STRING | accessible-for-notify | current |
| hwUsbOperType OBJECT-TYPE The staus of usb card. | 1.3.6.1.4.1.2011.5.25.219.1.14 | Integer32 | read-write | current |
| hwOpticalVendorName OBJECT-TYPE The vendor name of optical module. | 1.3.6.1.4.1.2011.5.25.219.1.15 | OCTET STRING | accessible-for-notify | current |
| hwOpticalVendorSN OBJECT-TYPE The vendor serial number of optical module. | 1.3.6.1.4.1.2011.5.25.219.1.16 | OCTET STRING | accessible-for-notify | current |
| hwMasterOpUser OBJECT-TYPE The master user name of virtual-access configuration. | 1.3.6.1.4.1.2011.5.25.219.1.17 | OCTET STRING | accessible-for-notify | current |
| hwAPAdminIP OBJECT-TYPE The AP admin ip address of virtual-access configuration. | 1.3.6.1.4.1.2011.5.25.219.1.18 | OCTET STRING | accessible-for-notify | current |
| hwAPID OBJECT-TYPE The ap-id of virtual-access configuration. | 1.3.6.1.4.1.2011.5.25.219.1.19 | Integer32 | accessible-for-notify | current |
| hwOperation OBJECT-TYPE The operation of virtual-access configuration. | 1.3.6.1.4.1.2011.5.25.219.1.20 | OCTET STRING | accessible-for-notify | current |
| hwReason OBJECT-TYPE The failure reason of virtual-access configuration. | 1.3.6.1.4.1.2011.5.25.219.1.21 | OCTET STRING | accessible-for-notify | current |
| vmName OBJECT-TYPE The name of VM. | 1.3.6.1.4.1.2011.5.25.219.1.23 | OCTET STRING | accessible-for-notify | current |
| hwEntityBandwidthMode OBJECT-TYPE The bandwidth mode of card. | 1.3.6.1.4.1.2011.5.25.219.1.24 | INTEGER {eth28x10gf(1), eth26x10gf18xgf(2), eth20x10gf24xgf(3)} | read-only | current |
| hwPartitionTable OBJECT-TYPE This table describes disk partition information. Currently, it is only used for disk partition-related alarms. Creation Restriction: No entry can be created in this table. Modification Restriction: The entries in this table cannot be modified. Deletion Restriction: The entries in this table cannot be deleted. Access Restriction: The entries in this table cannot be accessed. | 1.3.6.1.4.1.2011.5.25.219.1.25 | not-accessible | current | |
| hwPartitionEntry OBJECT-TYPE A device disk partition entry. Each entry consists of information of a device disk partition. hwPartitionEntPhysicalName and hwPartitionName exclusively decide a device disk partition. | 1.3.6.1.4.1.2011.5.25.219.1.25.1 | not-accessible | current | |
| hwPartitionEntPhysicalName OBJECT-TYPE This object indicates an entity name. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.1 | OCTET STRING | accessible-for-notify | current |
| hwPartitionName OBJECT-TYPE This object indicates a disk partition name. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.2 | OCTET STRING | accessible-for-notify | current |
| hwPartitionSpaceFree OBJECT-TYPE This object indicates the remaining disk partition space for the user, in MB. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.3 | Integer32 | accessible-for-notify | current |
| hwPartitionSpaceFreeThreshold OBJECT-TYPE This object indicates the threshold for the remaining disk partition space for the user, in MB. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.4 | Integer32 | accessible-for-notify | current |
| hwPartitionUseage OBJECT-TYPE This object indicates the current disk partition usage, in percentage. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.5 | Integer32 | accessible-for-notify | current |
| hwPartitionUseageThreshold OBJECT-TYPE This object indicates the threshold for the disk partition usage, in percentage. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.6 | Integer32 | accessible-for-notify | current |
| hwEntPhysicalUbiIndex OBJECT-TYPE This object indicates the current physical ubi index number. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.7 | Integer32 | accessible-for-notify | current |
| hwEntCurrentBadPhysicalBlocks OBJECT-TYPE This object indicates the current bad physical blocks number. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.8 | Integer32 | accessible-for-notify | current |
| hwEntBadPhysicalBlocksThreshold OBJECT-TYPE This object indicates the threshold for the bad physical blocks number. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.9 | Integer32 | accessible-for-notify | current |
| hwEntMaxErasePhysicalBlocks OBJECT-TYPE This object indicates the max erase physica blocks number. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.10 | Integer32 | accessible-for-notify | current |
| hwEntErasePhysicalBlocksThreshold OBJECT-TYPE This object indicates the threshold for the max erase physical blocks number. | 1.3.6.1.4.1.2011.5.25.219.1.25.1.11 | Integer32 | accessible-for-notify | current |
| hwEntPhysicalName OBJECT-TYPE This object indicates an entity name. | 1.3.6.1.4.1.2011.5.25.219.1.26 | OCTET STRING | accessible-for-notify | current |
| hwBoardID OBJECT-TYPE Board ID. | 1.3.6.1.4.1.2011.5.25.219.1.27 | Integer32 | accessible-for-notify | current |
| hwPowerWorkMode OBJECT-TYPE AP power work mode. | 1.3.6.1.4.1.2011.5.25.219.1.28 | OCTET STRING | accessible-for-notify | current |
| hwExpectPowerWorkMode OBJECT-TYPE AP excepted power work mode. | 1.3.6.1.4.1.2011.5.25.219.1.29 | OCTET STRING | accessible-for-notify | current |
| hwCapCPUThresholdType OBJECT-TYPE The type of changes of Cap CPU Utilization. | 1.3.6.1.4.1.2011.5.25.219.1.30 | Integer32 | accessible-for-notify | current |
| hwCapCPUThresholdValue OBJECT-TYPE The threshold value of Cap CPU Utilization. | 1.3.6.1.4.1.2011.5.25.219.1.31 | Integer32 | accessible-for-notify | current |
| hwCapCPUThresholdCurrent OBJECT-TYPE The average value of Cap CPU Utilization. | 1.3.6.1.4.1.2011.5.25.219.1.32 | Integer32 | accessible-for-notify | current |
| hwSyslogModuleName OBJECT-TYPE The module name of syslog. | 1.3.6.1.4.1.2011.5.25.219.1.33 | OCTET STRING | accessible-for-notify | current |
| hwSyslogSeverityLevel OBJECT-TYPE The severity of syslog. | 1.3.6.1.4.1.2011.5.25.219.1.34 | Integer32 | accessible-for-notify | current |
| hwSyslogBrief OBJECT-TYPE The brief of syslog. | 1.3.6.1.4.1.2011.5.25.219.1.35 | OCTET STRING | accessible-for-notify | current |
| hwSyslogDescription OBJECT-TYPE The description of syslog. | 1.3.6.1.4.1.2011.5.25.219.1.36 | OCTET STRING | accessible-for-notify | current |
| hwSyslogTimeStamp OBJECT-TYPE The time stamp of syslog. | 1.3.6.1.4.1.2011.5.25.219.1.37 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsTrapObject OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.1.38 | |||
| hwEntityNpsVMName OBJECT-TYPE VM name. | 1.3.6.1.4.1.2011.5.25.219.1.38.1 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsVMID OBJECT-TYPE VMID of the MANO layer. | 1.3.6.1.4.1.2011.5.25.219.1.38.2 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPhyVMID OBJECT-TYPE VMID of the physical layer. | 1.3.6.1.4.1.2011.5.25.219.1.38.3 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsErrorCode OBJECT-TYPE The error code. | 1.3.6.1.4.1.2011.5.25.219.1.38.4 | Integer32 | accessible-for-notify | current |
| hwEntityNpsErrorDescr OBJECT-TYPE To describe the error of the trap. | 1.3.6.1.4.1.2011.5.25.219.1.38.5 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPort OBJECT-TYPE The port of the virtual machine. | 1.3.6.1.4.1.2011.5.25.219.1.38.6 | Integer32 | accessible-for-notify | current |
| hwEntityNpsPortName OBJECT-TYPE The port name of the virtual machine. | 1.3.6.1.4.1.2011.5.25.219.1.38.7 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsIPAddress OBJECT-TYPE The IP address of the virtual machine. | 1.3.6.1.4.1.2011.5.25.219.1.38.8 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPatchName OBJECT-TYPE The patch file name. | 1.3.6.1.4.1.2011.5.25.219.1.38.9 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPatchVersion OBJECT-TYPE The patch file version. | 1.3.6.1.4.1.2011.5.25.219.1.38.10 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsCertName OBJECT-TYPE The certificate file name. | 1.3.6.1.4.1.2011.5.25.219.1.38.11 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsCertType OBJECT-TYPE The certificate type. | 1.3.6.1.4.1.2011.5.25.219.1.38.12 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsCertRemainDays OBJECT-TYPE The remain days of the certificate. | 1.3.6.1.4.1.2011.5.25.219.1.38.13 | Integer32 | accessible-for-notify | current |
| hwEntityNpsCertValidBeginTime OBJECT-TYPE The certificate valid begin time. | 1.3.6.1.4.1.2011.5.25.219.1.38.14 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsCertValidEndTime OBJECT-TYPE The certificate valid end time. | 1.3.6.1.4.1.2011.5.25.219.1.38.15 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPartitionName OBJECT-TYPE The disk partition name. | 1.3.6.1.4.1.2011.5.25.219.1.38.16 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsPartitionUsage OBJECT-TYPE The usage of the disk partition. | 1.3.6.1.4.1.2011.5.25.219.1.38.17 | Integer32 | accessible-for-notify | current |
| hwEntityNpsPartitionUsageThreshold OBJECT-TYPE The disk partition usage overload threshold. | 1.3.6.1.4.1.2011.5.25.219.1.38.18 | Integer32 | accessible-for-notify | current |
| hwEntityNpsPartitionAvailableSpace OBJECT-TYPE The available space of the disk partition. | 1.3.6.1.4.1.2011.5.25.219.1.38.19 | Integer32 | accessible-for-notify | current |
| hwEntityNpsPartitionCapacityThreshold OBJECT-TYPE The capacity threshold of the disk partition. | 1.3.6.1.4.1.2011.5.25.219.1.38.20 | Integer32 | accessible-for-notify | current |
| hwEntityNpsRUName OBJECT-TYPE The name of RU. | 1.3.6.1.4.1.2011.5.25.219.1.38.21 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsVNFCName OBJECT-TYPE The name of the VNFC. | 1.3.6.1.4.1.2011.5.25.219.1.38.22 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsVNFCType OBJECT-TYPE The type of the VNFC. | 1.3.6.1.4.1.2011.5.25.219.1.38.23 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsAPPType OBJECT-TYPE The application type. | 1.3.6.1.4.1.2011.5.25.219.1.38.24 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsSoftwareVersionType OBJECT-TYPE The application version type. | 1.3.6.1.4.1.2011.5.25.219.1.38.25 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsSoftwareVersionID OBJECT-TYPE The application version id. | 1.3.6.1.4.1.2011.5.25.219.1.38.26 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsLocalVMName OBJECT-TYPE The local VM name. | 1.3.6.1.4.1.2011.5.25.219.1.38.27 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsRemoteVMName OBJECT-TYPE The remote VM name. | 1.3.6.1.4.1.2011.5.25.219.1.38.28 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsNetworkPlaneID OBJECT-TYPE The network plane id. | 1.3.6.1.4.1.2011.5.25.219.1.38.29 | Integer32 | accessible-for-notify | current |
| hwEntityNpsNetworkErrorThreshold OBJECT-TYPE The network subhealth threshold. | 1.3.6.1.4.1.2011.5.25.219.1.38.30 | Integer32 | accessible-for-notify | current |
| hwEntityNpsDeviceID OBJECT-TYPE The device id. | 1.3.6.1.4.1.2011.5.25.219.1.38.31 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsDriverVendor OBJECT-TYPE The driver vendor. | 1.3.6.1.4.1.2011.5.25.219.1.38.32 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsDriverType OBJECT-TYPE The driver type of device. | 1.3.6.1.4.1.2011.5.25.219.1.38.33 | OCTET STRING | accessible-for-notify | current |
| hwEntityNpsQuality OBJECT-TYPE The quality of base. | 1.3.6.1.4.1.2011.5.25.219.1.38.34 | Integer32 | accessible-for-notify | current |
| hwEntityConfigurationTrapObject OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.1.39 | |||
| hwEntityConfigurationCurrent OBJECT-TYPE The current configuraiton. | 1.3.6.1.4.1.2011.5.25.219.1.39.1 | OCTET STRING | accessible-for-notify | current |
| hwEntityConfigurationRollbackReason OBJECT-TYPE The configuration rollback reason. | 1.3.6.1.4.1.2011.5.25.219.1.39.2 | OCTET STRING | accessible-for-notify | current |
| hwLicenseRemainTime OBJECT-TYPE The remain time of virtual license. | 1.3.6.1.4.1.2011.5.25.219.1.40 | Integer32 | accessible-for-notify | current |
| hwLpuSlotId OBJECT-TYPE The Id of the lpu board. | 1.3.6.1.4.1.2011.5.25.219.1.41 | Integer32 | accessible-for-notify | current |
| hwLpuFeId OBJECT-TYPE Np id. | 1.3.6.1.4.1.2011.5.25.219.1.42 | Integer32 | accessible-for-notify | current |
| hwDropCauseId OBJECT-TYPE The cause id of drop packet. | 1.3.6.1.4.1.2011.5.25.219.1.43 | Integer32 | accessible-for-notify | current |
| hwVirtualLicenseItemName OBJECT-TYPE The item name of virtual license. | 1.3.6.1.4.1.2011.5.25.219.1.44 | OCTET STRING | accessible-for-notify | current |
| hwEntityTraps OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2 | |||
| hwChassisTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.1 | |||
| hwBoardTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.2 | |||
| hwCardTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.3 | |||
| hwOpticalTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.4 | |||
| hwPowerTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.5 | |||
| hwFanTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.6 | |||
| hwLcdTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.7 | |||
| hwCmuTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.8 | |||
| hwCommunicateTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.9 | |||
| hwEnvironmentTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.10 | |||
| hwSystemConfigTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.11 | |||
| hwPortTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.12 | |||
| hwUserDefTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.13 | |||
| hwCPUTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.14 | |||
| hwMemoryTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.15 | |||
| hwStorageDevTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.16 | |||
| hwPppTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.17 | |||
| hwFileStatusTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.18 | |||
| hwUSBTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.19 | |||
| hwPmuTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.20 | |||
| hwTRAFFICTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.21 | |||
| hwBatteryTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.22 | |||
| hwThreadTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.23 | |||
| hwDiskTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.24 | |||
| hwVMTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.25 | |||
| hwDataplaneCpuOverloadTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.29 | |||
| hwInsSpaceLackTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.30 | |||
| hwVfpSysCheckErrTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.31 | |||
| hwCapCPUTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.32 | |||
| hwPDUTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.33 | |||
| hwSyslogTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.34 | |||
| hwEntityNpsTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.35 | |||
| hwEntityConfigurationTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.36 | |||
| hwNPDomainDropCauseCntNumabruptlyTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.37 | |||
| hwNPResourceExcTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.38 | |||
| hwEntityFileSystemTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.39 | |||
| hwEntityHardewareFaultTrap OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.2.40 | |||
| hwEntityTrapConformance OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.3 | |||
| hwEntityTrapCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.3.1 | |||
| hwEntityTrapGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.219.3.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| hwChassisRemove NOTIFICATION-TYPE This object indicates that a chassis cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.1.1 | current |
| hwChassisInsert NOTIFICATION-TYPE This object indicates that a chassis can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.1.2 | current |
| hwChassisFail NOTIFICATION-TYPE This object indicates that a chassis encounters a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.1.3 | current |
| hwChassisFailResume NOTIFICATION-TYPE This object indicates that a chassis recovers from a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.1.4 | current |
| hwChassisInvalid NOTIFICATION-TYPE This object indicates that a chassis encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.1.5 | current |
| hwChassisInvalidResume NOTIFICATION-TYPE This object indicates that a chassis recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.1.6 | current |
| hwBoardRemove NOTIFICATION-TYPE This object indicates that a board cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.2.1 | current |
| hwBoardInsert NOTIFICATION-TYPE This object indicates that a board can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.2.2 | current |
| hwBoardFail NOTIFICATION-TYPE This object indicates that a board encounters a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.3 | current |
| hwBoardFailResume NOTIFICATION-TYPE This object indicates that a board recovers from a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.4 | current |
| hwBoardInvalid NOTIFICATION-TYPE This object indicates that a board encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.5 | current |
| hwBoardInvalidResume NOTIFICATION-TYPE This object indicates that a board recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.6 | current |
| hwBoardLeaveMaster NOTIFICATION-TYPE This object indicates that a board exits from the active state. | 1.3.6.1.4.1.2011.5.25.219.2.2.7 | current |
| hwBoardBecomeMaster NOTIFICATION-TYPE This object indicates that a board enters the active state. | 1.3.6.1.4.1.2011.5.25.219.2.2.8 | current |
| hwUpMicroSwitchOpen NOTIFICATION-TYPE Up micro switch open. | 1.3.6.1.4.1.2011.5.25.219.2.2.9 | current |
| hwUpMicroSwitchClose NOTIFICATION-TYPE Up micro switch close. | 1.3.6.1.4.1.2011.5.25.219.2.2.10 | current |
| hwDownMicroSwitchOpen NOTIFICATION-TYPE Down micro switch open. | 1.3.6.1.4.1.2011.5.25.219.2.2.11 | current |
| hwDownMicroSwitchClose NOTIFICATION-TYPE Down micro switch close. | 1.3.6.1.4.1.2011.5.25.219.2.2.12 | current |
| hwBoardPowerOff NOTIFICATION-TYPE The LPU is powered off, because this LPU only supports the trunks with index 127 or smaller than 127. | 1.3.6.1.4.1.2011.5.25.219.2.2.13 | current |
| hwBandwidthOfAllCardsExceedsThreshold NOTIFICATION-TYPE The total bandwidth of all cards exceeds the forwarding capacity of system control board. | 1.3.6.1.4.1.2011.5.25.219.2.2.14 | current |
| hwBoardResetByCmd NOTIFICATION-TYPE This object indicates that the board experiences a command-triggred reset. | 1.3.6.1.4.1.2011.5.25.219.2.2.15 | current |
| hwBoardResetByCmdResume NOTIFICATION-TYPE This object indicates that the board recovers from a command-triggred reset. | 1.3.6.1.4.1.2011.5.25.219.2.2.16 | current |
| hwBoardHeartbeatTimeout NOTIFICATION-TYPE The heartbeat connection between the board and main control board timed out. | 1.3.6.1.4.1.2011.5.25.219.2.2.17 | current |
| hwBoardHeartbeatResume NOTIFICATION-TYPE The heartbeat connection between the board and main control board was restored. | 1.3.6.1.4.1.2011.5.25.219.2.2.18 | current |
| hwBandwidthOfAllCardsExceedsThresholdAlarm NOTIFICATION-TYPE The total bandwidth of all cards exceeds the forwarding capacity of system control board. | 1.3.6.1.4.1.2011.5.25.219.2.2.19 | current |
| hwBandwidthOfAllCardsExceedsThresholdResume NOTIFICATION-TYPE The total bandwidth of all cards recovered from exceeding the forwarding capacity of system control board. | 1.3.6.1.4.1.2011.5.25.219.2.2.20 | current |
| hwBandwidthOfAllCardsExceedsThresholdFatalAlarm NOTIFICATION-TYPE The total bandwidth of all cards exceeds the fatal forwarding capacity of system control board. | 1.3.6.1.4.1.2011.5.25.219.2.2.21 | current |
| hwBandwidthOfAllCardsExceedsThresholdFatalResume NOTIFICATION-TYPE The total bandwidth of all cards recovered from exceeding the fatal forwarding capacity of system control board. | 1.3.6.1.4.1.2011.5.25.219.2.2.22 | current |
| hwPinchCardReset NOTIFICATION-TYPE The pinch card reset. | 1.3.6.1.4.1.2011.5.25.219.2.2.23 | current |
| hwPinchCardResetResume NOTIFICATION-TYPE The pinch card recovered from reset. | 1.3.6.1.4.1.2011.5.25.219.2.2.24 | current |
| hwVBoardInvalid NOTIFICATION-TYPE Board is invalid for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.2.27 | current |
| hwVBoardInvalidResume NOTIFICATION-TYPE Board resume from invalid situation. | 1.3.6.1.4.1.2011.5.25.219.2.2.28 | current |
| hwNeedModifyCfgTrap NOTIFICATION-TYPE Before a version upgrade, the system checks the configuration files. If there is any problem, the system informs the user of the problem. After the upgrade, the system informs the user that the device needs to be restarted and configured again. | 1.3.6.1.4.1.2011.5.25.219.2.2.29 | current |
| hwBoardWarning NOTIFICATION-TYPE The board experienced a minor fault. | 1.3.6.1.4.1.2011.5.25.219.2.2.30 | current |
| hwBoardWarningResume NOTIFICATION-TYPE The board resumed from the minor fault. | 1.3.6.1.4.1.2011.5.25.219.2.2.31 | current |
| hwBoardPortsConflict NOTIFICATION-TYPE Some ports on the board and subcard conflict with each other. | 1.3.6.1.4.1.2011.5.25.219.2.2.32 | current |
| hwBoardEntityPowerOff NOTIFICATION-TYPE The mpu board is powered off. | 1.3.6.1.4.1.2011.5.25.219.2.2.33 | current |
| hwBoardlowmemoryoverload NOTIFICATION-TYPE The low-end memory usage exceeds 95 percent. | 1.3.6.1.4.1.2011.5.25.219.2.2.34 | current |
| hwBoardlowmemoryoverloadResume NOTIFICATION-TYPE The low-end memory usage resumes from the overload limit. | 1.3.6.1.4.1.2011.5.25.219.2.2.35 | current |
| hwBoardAdd NOTIFICATION-TYPE The board was added. | 1.3.6.1.4.1.2011.5.25.219.2.2.36 | current |
| hwBoardDelete NOTIFICATION-TYPE The board was deleted. | 1.3.6.1.4.1.2011.5.25.219.2.2.37 | current |
| hwAllLpuSfuFail NOTIFICATION-TYPE All installed LPUs and SFUs were not registered for a long time. | 1.3.6.1.4.1.2011.5.25.219.2.2.38 | current |
| hwAllLpuSfuFailResume NOTIFICATION-TYPE Not all installed LPUs and SFUs were not registered. | 1.3.6.1.4.1.2011.5.25.219.2.2.39 | current |
| hwBoardUpCoverAlarm NOTIFICATION-TYPE The cover is opened. | 1.3.6.1.4.1.2011.5.25.219.2.2.40 | current |
| hwBoardUpCoverResume NOTIFICATION-TYPE The cover is closed. | 1.3.6.1.4.1.2011.5.25.219.2.2.41 | current |
| hwTmPerformanceALarm NOTIFICATION-TYPE This object indicates that a board encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.42 | current |
| hwTmPerformanceResume NOTIFICATION-TYPE This object indicates that a board recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.2.43 | current |
| hwCardRemove NOTIFICATION-TYPE This object indicates that a card cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.3.1 | current |
| hwCardInsert NOTIFICATION-TYPE This object indicates that a card can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.3.2 | current |
| hwCardFail NOTIFICATION-TYPE Card become failure for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.3.3 | current |
| hwCardFailResume NOTIFICATION-TYPE Card resume from failure. | 1.3.6.1.4.1.2011.5.25.219.2.3.4 | current |
| hwCardInvalid NOTIFICATION-TYPE Card is invalid for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.3.5 | current |
| hwCardInvalidResume NOTIFICATION-TYPE Card resume from invalid situation. | 1.3.6.1.4.1.2011.5.25.219.2.3.6 | current |
| hwCardResetByCmd NOTIFICATION-TYPE This object indicates that the card experiences a command-triggred reset. | 1.3.6.1.4.1.2011.5.25.219.2.3.7 | current |
| hwCardResetByCmdResume NOTIFICATION-TYPE This object indicates that the card recovers from a command-triggred reset. | 1.3.6.1.4.1.2011.5.25.219.2.3.8 | current |
| hwCardResExceed NOTIFICATION-TYPE This object indicates that the resource of card exceeds the maximum limit. | 1.3.6.1.4.1.2011.5.25.219.2.3.9 | current |
| hwCardResExceedResume NOTIFICATION-TYPE This object indicates that the card recovers from resource exceeding the maximum limit. | 1.3.6.1.4.1.2011.5.25.219.2.3.10 | current |
| hwCardBandwidthModeChange NOTIFICATION-TYPE The bandwidth mode of physical entity is changed. | 1.3.6.1.4.1.2011.5.25.219.2.3.11 | current |
| hwCardSplitChange NOTIFICATION-TYPE Port split configuration has changed on the card. | 1.3.6.1.4.1.2011.5.25.219.2.3.12 | current |
| hwCardInconsistent NOTIFICATION-TYPE The card types are different. | 1.3.6.1.4.1.2011.5.25.219.2.3.13 | current |
| hwRTULicenseActSuccess NOTIFICATION-TYPE Succeed to activate the RTU license. | 1.3.6.1.4.1.2011.5.25.219.2.3.14 | current |
| hwOpticalRemove NOTIFICATION-TYPE Optical Module has been removed. | 1.3.6.1.4.1.2011.5.25.219.2.4.1 | current |
| hwOpticalInsert NOTIFICATION-TYPE Optical Module has been inserted. | 1.3.6.1.4.1.2011.5.25.219.2.4.2 | current |
| hwOpticalFail NOTIFICATION-TYPE Optical Module become failure for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.4.3 | current |
| hwOpticalFailResume NOTIFICATION-TYPE Optical Module resume from failure. | 1.3.6.1.4.1.2011.5.25.219.2.4.4 | current |
| hwOpticalInvalid NOTIFICATION-TYPE Optical Module is invalid for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.4.5 | current |
| hwOpticalInvalidResume NOTIFICATION-TYPE Optical Module resume from invalid situation. | 1.3.6.1.4.1.2011.5.25.219.2.4.6 | current |
| hwOpticalPowerAlarm NOTIFICATION-TYPE Temperature rise over or fall below the warning alarm threshold. Only indicate the temperature of board,card or optical module. | 1.3.6.1.4.1.2011.5.25.219.2.4.7 | current |
| hwOpticalPowerAlarmResume NOTIFICATION-TYPE Temperature rise over or fall below the warning alarm threshold. Only indicate the temperature of board,card or optical module. | 1.3.6.1.4.1.2011.5.25.219.2.4.8 | current |
| hwOpticalUnAuthorized NOTIFICATION-TYPE The optical module authentication alarm occured. | 1.3.6.1.4.1.2011.5.25.219.2.4.9 | current |
| hwOpticalUnAuthorizedResume NOTIFICATION-TYPE The optical module authentication alarm resumed. | 1.3.6.1.4.1.2011.5.25.219.2.4.10 | current |
| hwLaserNoFited NOTIFICATION-TYPE The laser not installed alarm occured. | 1.3.6.1.4.1.2011.5.25.219.2.4.11 | current |
| hwLaserNoFitedResume NOTIFICATION-TYPE The laser not installed alarm resumed. | 1.3.6.1.4.1.2011.5.25.219.2.4.12 | current |
| hwOpticalTunableNotMatch NOTIFICATION-TYPE Configuration collision occurred between wavelength setting and untunable optical module. | 1.3.6.1.4.1.2011.5.25.219.2.4.13 | current |
| hwOpticalTunableNotMatchResume NOTIFICATION-TYPE Configuration collision removed between wavelength setting and untunable optical module. | 1.3.6.1.4.1.2011.5.25.219.2.4.14 | current |
| hwGpsModuleRemove NOTIFICATION-TYPE The gps module was removed. | 1.3.6.1.4.1.2011.5.25.219.2.4.15 | current |
| hwGpsModuleInsert NOTIFICATION-TYPE The gps module was inserted. | 1.3.6.1.4.1.2011.5.25.219.2.4.16 | current |
| hwOptCfgNotMatch NOTIFICATION-TYPE The partial function of optical module failed. | 1.3.6.1.4.1.2011.5.25.219.2.4.17 | current |
| hwOptCfgNotMatchResume NOTIFICATION-TYPE The partial function of optical module resumed from partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.4.18 | current |
| hwPowerRemove NOTIFICATION-TYPE This object indicates that the power supply cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.5.1 | current |
| hwPowerInsert NOTIFICATION-TYPE This object indicates that the power supply can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.5.2 | current |
| hwPowerFail NOTIFICATION-TYPE This object indicates that the power supply encounters a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.5.3 | current |
| hwPowerFailResume NOTIFICATION-TYPE This object indicates that the power supply recovers from a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.5.4 | current |
| hwPowerInvalid NOTIFICATION-TYPE This object indicates that the power supply encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.5.5 | current |
| hwPowerInvalidResume NOTIFICATION-TYPE This object indicates that the power supply recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.5.6 | current |
| hwPowerUnusable NOTIFICATION-TYPE This object indicates that the power supply is unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.5.7 | current |
| hwPowerUnusableResume NOTIFICATION-TYPE This object indicates that the power supply is unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.5.8 | current |
| hwPowerInsufficient NOTIFICATION-TYPE AP power supply is insufficient. | 1.3.6.1.4.1.2011.5.25.219.2.5.9 | current |
| hwPowerInsufficientResume NOTIFICATION-TYPE AP power supply insufficient resume. | 1.3.6.1.4.1.2011.5.25.219.2.5.10 | current |
| hwFanRemove NOTIFICATION-TYPE This object indicates that a fan cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.6.1 | current |
| hwFanInsert NOTIFICATION-TYPE This object indicates that a fan can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.6.2 | current |
| hwFanFail NOTIFICATION-TYPE This object indicates that a fan encounters a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.6.3 | current |
| hwFanFailResume NOTIFICATION-TYPE This object indicates that a fan recovers from a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.6.4 | current |
| hwFanInvalid NOTIFICATION-TYPE This object indicates that a fan encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.6.5 | current |
| hwFanInvalidResume NOTIFICATION-TYPE This object indicates that a fan recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.6.6 | current |
| hwFanUnusable NOTIFICATION-TYPE This object indicates that a fan is unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.6.7 | current |
| hwFanUnusableResume NOTIFICATION-TYPE This object indicates that a fan becomes available. | 1.3.6.1.4.1.2011.5.25.219.2.6.8 | current |
| hwFanMinorAlarm NOTIFICATION-TYPE This object indicates that a minor fault occurred on the fan. | 1.3.6.1.4.1.2011.5.25.219.2.6.9 | current |
| hwFanMinorAlarmResume NOTIFICATION-TYPE This object indicates that the fan module recovered from the minor fault. | 1.3.6.1.4.1.2011.5.25.219.2.6.10 | current |
| hwLcdRemove NOTIFICATION-TYPE Lcd has been removed. | 1.3.6.1.4.1.2011.5.25.219.2.7.1 | current |
| hwLcdInsert NOTIFICATION-TYPE Lcd has been inserted. | 1.3.6.1.4.1.2011.5.25.219.2.7.2 | current |
| hwLcdInvalid NOTIFICATION-TYPE Lcd is invalid for some reason. | 1.3.6.1.4.1.2011.5.25.219.2.7.3 | current |
| hwLcdInvalidResume NOTIFICATION-TYPE Lcd resume from invalid situation. | 1.3.6.1.4.1.2011.5.25.219.2.7.4 | current |
| hwLcdUnusable NOTIFICATION-TYPE Lcd change to unusable status. | 1.3.6.1.4.1.2011.5.25.219.2.7.5 | current |
| hwLcdUnusableResume NOTIFICATION-TYPE Lcd change to usable status. | 1.3.6.1.4.1.2011.5.25.219.2.7.6 | current |
| hwCmuRemove NOTIFICATION-TYPE This object indicates that a CMU cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.8.1 | current |
| hwCmuInsert NOTIFICATION-TYPE This object indicates that a CMU can be detected. | 1.3.6.1.4.1.2011.5.25.219.2.8.2 | current |
| hwCmuInvalid NOTIFICATION-TYPE This object indicates that a CMU encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.8.3 | current |
| hwCmuInvalidResume NOTIFICATION-TYPE This object indicates that a CMU recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.8.4 | current |
| hwCmuUnusable NOTIFICATION-TYPE This object indicates that a CMU is unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.8.5 | current |
| hwCmuUnusableResume NOTIFICATION-TYPE This object indicates that a CMU becomes available. | 1.3.6.1.4.1.2011.5.25.219.2.8.6 | current |
| hwCommunicateError NOTIFICATION-TYPE This object indicates that a channel is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.9.1 | current |
| hwCommunicateResume NOTIFICATION-TYPE This object indicates that a channel recovers from a fault. | 1.3.6.1.4.1.2011.5.25.219.2.9.2 | current |
| hwTempAlarm NOTIFICATION-TYPE This object indicates that the ambient temperature is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.1 | current |
| hwTempResume NOTIFICATION-TYPE This object indicates that the ambient temperature recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.2 | current |
| hwHumidityAlarm NOTIFICATION-TYPE This object indicates that the ambient humidity is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.3 | current |
| hwHumidityResume NOTIFICATION-TYPE This object indicates that the ambient humidity recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.4 | current |
| hwVoltAlarm NOTIFICATION-TYPE This object indicates that the ambient voltage is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.5 | current |
| hwVoltResume NOTIFICATION-TYPE This object indicates that the ambient voltage recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.6 | current |
| hwGateAlarm NOTIFICATION-TYPE This object indicates that the door control status is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.7 | current |
| hwGateResume NOTIFICATION-TYPE This object indicates that the door control status recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.8 | current |
| hwFogAlarm NOTIFICATION-TYPE This object indicates that the smoke sensor is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.9 | current |
| hwFogResume NOTIFICATION-TYPE This object indicates that the smoke sensor recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.10 | current |
| hwUnstableAlarm NOTIFICATION-TYPE This object indicates that a physical entity is not securely inserted. | 1.3.6.1.4.1.2011.5.25.219.2.10.11 | current |
| hwUnstableResume NOTIFICATION-TYPE This object indicates that a physical entity is securely inserted. | 1.3.6.1.4.1.2011.5.25.219.2.10.12 | current |
| hwBrdTempAlarm NOTIFICATION-TYPE This object indicates that the board temperature is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.10.13 | current |
| hwBrdTempResume NOTIFICATION-TYPE This object indicates that the board temperature recovers from an abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.14 | current |
| hwBrdTempFatalAlarm NOTIFICATION-TYPE This object indicates that the board temperature encounters a fatal abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.15 | current |
| hwBrdTempFatalResume NOTIFICATION-TYPE This object indicates that the board temperature recovers from a fatal abnormality. | 1.3.6.1.4.1.2011.5.25.219.2.10.16 | current |
| hwPowerFailureAlarm NOTIFICATION-TYPE Power supply failed. | 1.3.6.1.4.1.2011.5.25.219.2.10.17 | current |
| hwPowerFailureResume NOTIFICATION-TYPE Power supply resumed. | 1.3.6.1.4.1.2011.5.25.219.2.10.18 | current |
| hwIOSwitchOneAlarm NOTIFICATION-TYPE The IO-alarm 1 arise. | 1.3.6.1.4.1.2011.5.25.219.2.10.19 | current |
| hwIOSwitchOneAlarmResume NOTIFICATION-TYPE The IO-alarm 1 resumed. | 1.3.6.1.4.1.2011.5.25.219.2.10.20 | current |
| hwIOSwitchTwoAlarm NOTIFICATION-TYPE The IO-alarm 2 arise. | 1.3.6.1.4.1.2011.5.25.219.2.10.21 | current |
| hwIOSwitchTwoAlarmResume NOTIFICATION-TYPE The IO-alarm 2 resumed. | 1.3.6.1.4.1.2011.5.25.219.2.10.22 | current |
| hwIOSwitchThreeAlarm NOTIFICATION-TYPE The IO-alarm 3 arise. | 1.3.6.1.4.1.2011.5.25.219.2.10.23 | current |
| hwIOSwitchThreeAlarmResume NOTIFICATION-TYPE The IO-alarm 3 resumed. | 1.3.6.1.4.1.2011.5.25.219.2.10.24 | current |
| hwEntityDyingGaspEvent NOTIFICATION-TYPE Power supply failed. | 1.3.6.1.4.1.2011.5.25.219.2.10.25 | current |
| hwSystemConfigError NOTIFICATION-TYPE System configuration error has been detected. | 1.3.6.1.4.1.2011.5.25.219.2.11.1 | current |
| hwSystemConfigResume NOTIFICATION-TYPE Resume from system configuration error situation. | 1.3.6.1.4.1.2011.5.25.219.2.11.2 | current |
| hwSystemRollback NOTIFICATION-TYPE System configuration error has been detected. | 1.3.6.1.4.1.2011.5.25.219.2.11.3 | current |
| hwVirtualAccessDrvConfigError NOTIFICATION-TYPE System configuration error has been detected. | 1.3.6.1.4.1.2011.5.25.219.2.11.4 | current |
| hwPatchDelNeedReStartTrap NOTIFICATION-TYPE The device needs to restart after the patch is deleted. | 1.3.6.1.4.1.2011.5.25.219.2.11.5 | current |
| hwSMSReboot NOTIFICATION-TYPE The result of the SMS reboot function. | 1.3.6.1.4.1.2011.5.25.219.2.11.6 | current |
| hwVirtualLicenseNearDeadline NOTIFICATION-TYPE The virtual license of device is near deadline. | 1.3.6.1.4.1.2011.5.25.219.2.11.7 | current |
| hwVirtualLicenseExpire NOTIFICATION-TYPE The virtual license of device has expired. | 1.3.6.1.4.1.2011.5.25.219.2.11.8 | current |
| hwPortDown NOTIFICATION-TYPE One of the port physical connect down. | 1.3.6.1.4.1.2011.5.25.219.2.12.1 | current |
| hwPortUp NOTIFICATION-TYPE One of the port physical connect up. | 1.3.6.1.4.1.2011.5.25.219.2.12.2 | current |
| hwPortNoSupportOETrap NOTIFICATION-TYPE one of the stack port does not support the insertion of the O/E converter. | 1.3.6.1.4.1.2011.5.25.219.2.12.3 | current |
| hwPortRemove NOTIFICATION-TYPE One of the port is removed. | 1.3.6.1.4.1.2011.5.25.219.2.12.4 | current |
| hwPortInsert NOTIFICATION-TYPE One new port is inserted. | 1.3.6.1.4.1.2011.5.25.219.2.12.5 | current |
| hwPortOpticalPositionInvalid NOTIFICATION-TYPE The current port is invalid. | 1.3.6.1.4.1.2011.5.25.219.2.12.8 | current |
| hwPortOpticalPositionValid NOTIFICATION-TYPE The current port is valid. | 1.3.6.1.4.1.2011.5.25.219.2.12.9 | current |
| hwUserDefAlarm NOTIFICATION-TYPE User defined alarm has been detected. | 1.3.6.1.4.1.2011.5.25.219.2.13.1 | current |
| hwUserDefResume NOTIFICATION-TYPE Resume from User defined alarm. | 1.3.6.1.4.1.2011.5.25.219.2.13.2 | current |
| hwCPUUtilizationRising NOTIFICATION-TYPE CPU utilization overrun. | 1.3.6.1.4.1.2011.5.25.219.2.14.1 | current |
| hwCPUUtilizationResume NOTIFICATION-TYPE CPU utilization back to normal level | 1.3.6.1.4.1.2011.5.25.219.2.14.2 | current |
| hwCpuFail NOTIFICATION-TYPE A fault occurred in the CPU. | 1.3.6.1.4.1.2011.5.25.219.2.14.3 | current |
| hwCpuFailResume NOTIFICATION-TYPE The cpu resumed from failure. | 1.3.6.1.4.1.2011.5.25.219.2.14.4 | current |
| hwMemUtilizationRising NOTIFICATION-TYPE Memory utilization overrun. | 1.3.6.1.4.1.2011.5.25.219.2.15.1 | current |
| hwMemUtilizationResume NOTIFICATION-TYPE Memory utilization back to normal level | 1.3.6.1.4.1.2011.5.25.219.2.15.2 | current |
| hwStorageDevRemove NOTIFICATION-TYPE Memory utilization overrun. | 1.3.6.1.4.1.2011.5.25.219.2.16.1 | current |
| hwStorageDevInsert NOTIFICATION-TYPE Memory utilization back to normal level | 1.3.6.1.4.1.2011.5.25.219.2.16.2 | current |
| hwPppLoopbackDetect NOTIFICATION-TYPE The interface Loopback is detected. | 1.3.6.1.4.1.2011.5.25.219.2.17.1 | current |
| hwPppLoopbackDetResume NOTIFICATION-TYPE The interface is recovered from Loopback. | 1.3.6.1.4.1.2011.5.25.219.2.17.2 | current |
| hwFileError NOTIFICATION-TYPE Memory utilization overrun. | 1.3.6.1.4.1.2011.5.25.219.2.18.1 | current |
| hwFileErrorResume NOTIFICATION-TYPE Memory utilization back to normal level | 1.3.6.1.4.1.2011.5.25.219.2.18.2 | current |
| hwUSBInsert NOTIFICATION-TYPE The USB device has been inserted. | 1.3.6.1.4.1.2011.5.25.219.2.19.1 | current |
| hwUSBRemove NOTIFICATION-TYPE The USB device has been removed. | 1.3.6.1.4.1.2011.5.25.219.2.19.2 | current |
| hwUSBUnidentified NOTIFICATION-TYPE The USB device is unidentified. | 1.3.6.1.4.1.2011.5.25.219.2.19.3 | current |
| hwUSBUnidentifiedResume NOTIFICATION-TYPE The USB device resume from unidentified situation. | 1.3.6.1.4.1.2011.5.25.219.2.19.4 | current |
| hwUsbStatusChg NOTIFICATION-TYPE The USB device status has been changed. | 1.3.6.1.4.1.2011.5.25.219.2.19.5 | current |
| hwPmuRemove NOTIFICATION-TYPE This object indicates that a PMU board on the X16A cannot be detected. | 1.3.6.1.4.1.2011.5.25.219.2.20.1 | current |
| hwPmuInsert NOTIFICATION-TYPE This object indicates that a PMU is inserted into the X16A. | 1.3.6.1.4.1.2011.5.25.219.2.20.2 | current |
| hwPmuFail NOTIFICATION-TYPE This object indicates that a PMU on the X16A encounters a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.20.3 | current |
| hwPmuFailResume NOTIFICATION-TYPE This object indicates that a PMU on the X16A recovers from a partial failure. | 1.3.6.1.4.1.2011.5.25.219.2.20.4 | current |
| hwPmuInvalid NOTIFICATION-TYPE This object indicates that a PMU on the X16A encounters an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.20.5 | current |
| hwPmuInvalidResume NOTIFICATION-TYPE This object indicates that a PMU on the X16A recovers from an overall failure. | 1.3.6.1.4.1.2011.5.25.219.2.20.6 | current |
| hwRATEOFTRAFFICRising NOTIFICATION-TYPE Rate of traffic overrun. | 1.3.6.1.4.1.2011.5.25.219.2.21.1 | current |
| hwRATEOFTRAFFICResume NOTIFICATION-TYPE Rate of traffic back to normal level. | 1.3.6.1.4.1.2011.5.25.219.2.21.2 | current |
| hwBatteryFull NOTIFICATION-TYPE battery percent is full . | 1.3.6.1.4.1.2011.5.25.219.2.22.1 | current |
| hwUpsFaultTrap NOTIFICATION-TYPE The UPS battery is faulty. | 1.3.6.1.4.1.2011.5.25.219.2.22.2 | current |
| hwUpsFaultResume NOTIFICATION-TYPE The UPS battery fault is rectified. | 1.3.6.1.4.1.2011.5.25.219.2.22.3 | current |
| hwUpsPowerLow NOTIFICATION-TYPE Available power of the UPS battery is low. | 1.3.6.1.4.1.2011.5.25.219.2.22.4 | current |
| hwUpsPowerFull NOTIFICATION-TYPE Available power of the UPS battery is restored to the normal range. | 1.3.6.1.4.1.2011.5.25.219.2.22.5 | current |
| hwPowerCubeAlarm NOTIFICATION-TYPE Indicates that power cube Alarm. | 1.3.6.1.4.1.2011.5.25.219.2.22.6 | current |
| hwPowerCubeAlarmResume NOTIFICATION-TYPE Indicates that power cube Alarm Resume. | 1.3.6.1.4.1.2011.5.25.219.2.22.7 | current |
| hwRpsPowerRemove NOTIFICATION-TYPE This object indicates that the RPS power supply has been removed. | 1.3.6.1.4.1.2011.5.25.219.2.22.8 | current |
| hwRpsPowerInsert NOTIFICATION-TYPE This object indicates that an RPS power supply has been connected to the device. | 1.3.6.1.4.1.2011.5.25.219.2.22.9 | current |
| hwRpsPowerOn NOTIFICATION-TYPE This object indicates that the RPS power supply starts to provide power. | 1.3.6.1.4.1.2011.5.25.219.2.22.10 | current |
| hwRpsPowerOff NOTIFICATION-TYPE This object indicates that the RPS power supply stops providing power. | 1.3.6.1.4.1.2011.5.25.219.2.22.11 | current |
| hwRpsFanInvalid NOTIFICATION-TYPE This object indicates that fans of the RPS power supply have failed. | 1.3.6.1.4.1.2011.5.25.219.2.22.12 | current |
| hwRpsFanInvalidResume NOTIFICATION-TYPE This object indicates that fans of the RPS power supply have recovered. | 1.3.6.1.4.1.2011.5.25.219.2.22.13 | current |
| hwRpsTempInvalid NOTIFICATION-TYPE This object indicates that temperature of the RPS power supply is out of the normal range. | 1.3.6.1.4.1.2011.5.25.219.2.22.14 | current |
| hwRpsTempInvalidResume NOTIFICATION-TYPE This object indicates that temperature of the RPS power supply has restored to the normal range. | 1.3.6.1.4.1.2011.5.25.219.2.22.15 | current |
| hwThreadFaultIsolate NOTIFICATION-TYPE The faulty thread has been isolated. | 1.3.6.1.4.1.2011.5.25.219.2.23.1 | current |
| hwDiskUtilizationRising NOTIFICATION-TYPE Disk utilization overrun. | 1.3.6.1.4.1.2011.5.25.219.2.24.1 | current |
| hwDiskUtilizationResume NOTIFICATION-TYPE Disk utilization back to normal level | 1.3.6.1.4.1.2011.5.25.219.2.24.2 | current |
| hwDiskPartitionInValid NOTIFICATION-TYPE An alarm was generated when a disk partition was unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.24.3 | current |
| hwDiskPartitionInValidResume NOTIFICATION-TYPE The alarm was cleared when the disk partition became available. | 1.3.6.1.4.1.2011.5.25.219.2.24.4 | current |
| hwDiskPartitionSpacinsufficient NOTIFICATION-TYPE An alarm was generated when the disk partition's(except the log partition) available space was below the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.24.5 | current |
| hwDiskPartitionSpacinsufficientResume NOTIFICATION-TYPE The alarm was cleared when the disk partition's(except the log partition) available space was above the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.24.6 | current |
| hwDiskPartitionUseageRising NOTIFICATION-TYPE When the disk partition usage(except the log partition) is greater than the specified overload threshold within a statistical period, the alarm is reported. | 1.3.6.1.4.1.2011.5.25.219.2.24.7 | current |
| hwDiskPartitionUseageResume NOTIFICATION-TYPE When the disk partition usage(except the log partition) fell and remained below 10% of the specified overload threshold within a statistical period, the alarm is cleared. | 1.3.6.1.4.1.2011.5.25.219.2.24.8 | current |
| hwDiskInvalid NOTIFICATION-TYPE An alarm was generated when the disk was Invalid. | 1.3.6.1.4.1.2011.5.25.219.2.24.9 | current |
| hwDiskInvalidResume NOTIFICATION-TYPE The alarm was cleared when the disk became available. | 1.3.6.1.4.1.2011.5.25.219.2.24.10 | current |
| hwDiskBadPyhsicalBlocks NOTIFICATION-TYPE An alarm was generated when the disk bad phsical blocks over the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.24.11 | current |
| hwDiskErasePyhsicalBlocks NOTIFICATION-TYPE An alarm was generated when the disk max erase phsical blocks over the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.24.12 | current |
| hwVMResInconsist NOTIFICATION-TYPE Local VM resources are inconsistent with those on the MANO. | 1.3.6.1.4.1.2011.5.25.219.2.25.1 | current |
| hwVMResInconsistResume NOTIFICATION-TYPE Local VM resources are consistent with those on the MANO. | 1.3.6.1.4.1.2011.5.25.219.2.25.2 | current |
| hwDataplaneCpuOverloadAlarm NOTIFICATION-TYPE The dataplane CPU throughput exceeds specifications. | 1.3.6.1.4.1.2011.5.25.219.2.29.1 | current |
| hwDataplaneCpuOverloadResume NOTIFICATION-TYPE The dataplane CPU throughput exceeds specifications alarm cleared. | 1.3.6.1.4.1.2011.5.25.219.2.29.2 | current |
| hwInsSpaceLackAlarm NOTIFICATION-TYPE The instruction space required for the current configuration exceeds the total instruction space of the forwarding chip. | 1.3.6.1.4.1.2011.5.25.219.2.30.1 | current |
| hwInsSpaceLackResume NOTIFICATION-TYPE The instruction space required for the current configuration exceeds the total instruction space of the forwarding chip alarm cleared. | 1.3.6.1.4.1.2011.5.25.219.2.30.2 | current |
| hwVfpSysCheckErr NOTIFICATION-TYPE A kind of vfp system error occured. | 1.3.6.1.4.1.2011.5.25.219.2.31.1 | current |
| hwVfpSysCheckErrResume NOTIFICATION-TYPE Vfp system error goes away. | 1.3.6.1.4.1.2011.5.25.219.2.31.2 | current |
| hwCapCPUUtilizationRising NOTIFICATION-TYPE The average value of Cap CPU Utilization exceeds specifications. | 1.3.6.1.4.1.2011.5.25.219.2.32.1 | current |
| hwCapCPUUtilizationResume NOTIFICATION-TYPE The average value of Cap CPU utilization back to normal level. | 1.3.6.1.4.1.2011.5.25.219.2.32.2 | current |
| hwPduNotPresent NOTIFICATION-TYPE The PDU is not present. | 1.3.6.1.4.1.2011.5.25.219.2.33.1 | current |
| hwPduPresent NOTIFICATION-TYPE The PDU is present. | 1.3.6.1.4.1.2011.5.25.219.2.33.2 | current |
| hwPduCommLost NOTIFICATION-TYPE Communication with the PDU was lost. | 1.3.6.1.4.1.2011.5.25.219.2.33.3 | current |
| hwPduCommLostResume NOTIFICATION-TYPE Communication with the PDU was restored. | 1.3.6.1.4.1.2011.5.25.219.2.33.4 | current |
| hwPduDmuHardwareFault NOTIFICATION-TYPE A hardware fault occurred on the DMU. | 1.3.6.1.4.1.2011.5.25.219.2.33.5 | current |
| hwPduDmuHardwareFaultResume NOTIFICATION-TYPE The DMU recovered from a hardware fault. | 1.3.6.1.4.1.2011.5.25.219.2.33.6 | current |
| hwPduDMUAutoUpgradeFail NOTIFICATION-TYPE The automatic upgrade of DMU was failed. | 1.3.6.1.4.1.2011.5.25.219.2.33.7 | current |
| hwPduDMUAutoUpgradeFailResume NOTIFICATION-TYPE Automatic upgrade of the DMU was successful. | 1.3.6.1.4.1.2011.5.25.219.2.33.8 | current |
| hwPduDacsHardwareFault NOTIFICATION-TYPE A hardware fault occurred on the DACS. | 1.3.6.1.4.1.2011.5.25.219.2.33.9 | current |
| hwPduDacsHardwareFaultResume NOTIFICATION-TYPE The DACS recovered from a hardware fault. | 1.3.6.1.4.1.2011.5.25.219.2.33.10 | current |
| hwPduDacsTempAlarm NOTIFICATION-TYPE The temperature of the temperature sensor on the DACS is too high. | 1.3.6.1.4.1.2011.5.25.219.2.33.11 | current |
| hwPduDacsTempAlarmResume NOTIFICATION-TYPE The temperature of the temperature sensor on the DACS is normal. | 1.3.6.1.4.1.2011.5.25.219.2.33.12 | current |
| hwPduDacsI2CChannelFault NOTIFICATION-TYPE The IIC channel of the DACS failed. | 1.3.6.1.4.1.2011.5.25.219.2.33.13 | current |
| hwPduDacsI2CChannelFaultResume NOTIFICATION-TYPE The IIC channel of the DACS recovered. | 1.3.6.1.4.1.2011.5.25.219.2.33.14 | current |
| hwReportSyslogInfo NOTIFICATION-TYPE The information of syslog trap . | 1.3.6.1.4.1.2011.5.25.219.2.34.1 | current |
| hwEntityNpsPatchInstallFail NOTIFICATION-TYPE Patch package installation failed. | 1.3.6.1.4.1.2011.5.25.219.2.35.1 | current |
| hwEntityNpsPatchInstallFailResume NOTIFICATION-TYPE The patch-installation failure alarm is cleared. | 1.3.6.1.4.1.2011.5.25.219.2.35.2 | current |
| hwEntityNpsPatchPacketError NOTIFICATION-TYPE Patch package file error. | 1.3.6.1.4.1.2011.5.25.219.2.35.3 | current |
| hwEntityNpsPatchPacketErrorResume NOTIFICATION-TYPE Patch package file error restored. | 1.3.6.1.4.1.2011.5.25.219.2.35.4 | current |
| hwEntityNpsSysConfigError NOTIFICATION-TYPE A system configuration error occurs. | 1.3.6.1.4.1.2011.5.25.219.2.35.5 | current |
| hwEntityNpsSysConfigErrorResume NOTIFICATION-TYPE The system configuration error has been rectified. | 1.3.6.1.4.1.2011.5.25.219.2.35.6 | current |
| hwEntityNpsSslCertInvalidEarlyWarning NOTIFICATION-TYPE The inner SSL certificate will expire. | 1.3.6.1.4.1.2011.5.25.219.2.35.7 | current |
| hwEntityNpsSslCertInvalidEarlyResume NOTIFICATION-TYPE The inner SSL certificate was upgraded. | 1.3.6.1.4.1.2011.5.25.219.2.35.8 | current |
| hwEntityNpsSslCertInvalid NOTIFICATION-TYPE The inner SSL certificate was invalid. | 1.3.6.1.4.1.2011.5.25.219.2.35.9 | current |
| hwEntityNpsSslCertInvalidResume NOTIFICATION-TYPE The inner SSL certificate was repaired. | 1.3.6.1.4.1.2011.5.25.219.2.35.10 | current |
| hwEntityNpsDiskPartitionUsageExceedingThreshold NOTIFICATION-TYPE The disk usage exceeded the pre-set overload threshold. | 1.3.6.1.4.1.2011.5.25.219.2.35.11 | current |
| hwEntityNpsDiskPartitionUsageExceedingThresholdResume NOTIFICATION-TYPE The disk partition usage of the VM was 10% lower than the preset threshold. | 1.3.6.1.4.1.2011.5.25.219.2.35.12 | current |
| hwEntityNpsDiskPartitionUnavailable NOTIFICATION-TYPE The VM's disk partition was unavailable. | 1.3.6.1.4.1.2011.5.25.219.2.35.13 | current |
| hwEntityNpsDiskPartitionUnavailableResume NOTIFICATION-TYPE The fault where the VM's disk partition was unavailable was rectified. | 1.3.6.1.4.1.2011.5.25.219.2.35.14 | current |
| hwEntityNpsDiskPartitionSpaceInsufficient NOTIFICATION-TYPE The disk partition's available space was less than the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.35.15 | current |
| hwEntityNpsDiskPartitionSpaceInsufficientResume NOTIFICATION-TYPE The disk partition's available space was more than the threshold. | 1.3.6.1.4.1.2011.5.25.219.2.35.16 | current |
| hwEntityNpsExecutableFilesIncomplete NOTIFICATION-TYPE The file check failed. | 1.3.6.1.4.1.2011.5.25.219.2.35.17 | current |
| hwEntityNpsExecutableFilesIncompleteResume NOTIFICATION-TYPE The file check success. | 1.3.6.1.4.1.2011.5.25.219.2.35.18 | current |
| hwEntityNpsSoftwareIntegrityError NOTIFICATION-TYPE The software check failed. | 1.3.6.1.4.1.2011.5.25.219.2.35.19 | current |
| hwEntityNpsSoftwareIntegrityErrorResume NOTIFICATION-TYPE The software check success. | 1.3.6.1.4.1.2011.5.25.219.2.35.20 | current |
| hwEntityNpsOMUSyncFail NOTIFICATION-TYPE Data failed to be synchronized from the master OMU to the slave OMU. | 1.3.6.1.4.1.2011.5.25.219.2.35.21 | current |
| hwEntityNpsOMUSyncFailResume NOTIFICATION-TYPE A master/slave OMU data synchronization failure was removed, or the slave OMU became absent after a master/slave OMU data synchronization failure occurred. | 1.3.6.1.4.1.2011.5.25.219.2.35.22 | current |
| hwEntityNpsVMDiskUnavailable NOTIFICATION-TYPE A fault occurs on the VM disk. | 1.3.6.1.4.1.2011.5.25.219.2.35.23 | current |
| hwEntityNpsVMDiskUnavailableResume NOTIFICATION-TYPE The fault on the VM disk is cleared. | 1.3.6.1.4.1.2011.5.25.219.2.35.24 | current |
| hwEntityNpsDatabaseRestoreFail NOTIFICATION-TYPE Database Restoration Failure. | 1.3.6.1.4.1.2011.5.25.219.2.35.25 | current |
| hwEntityNpsSSLCertExpired NOTIFICATION-TYPE The certificate already expired. | 1.3.6.1.4.1.2011.5.25.219.2.35.26 | current |
| hwEntityNpsSSLCertExpiredEarlyWarning NOTIFICATION-TYPE The SSL certificate will expire. | 1.3.6.1.4.1.2011.5.25.219.2.35.27 | current |
| hwEntityNpsVMResInconsist NOTIFICATION-TYPE Local VM resources are inconsistent with those on the MANO. | 1.3.6.1.4.1.2011.5.25.219.2.35.28 | current |
| hwEntityNpsVMResInconsistResume NOTIFICATION-TYPE Local VM resources are consistent with those on the MANO. | 1.3.6.1.4.1.2011.5.25.219.2.35.29 | current |
| hwEntityNpsVmFault NOTIFICATION-TYPE A fault occurs on a VM. | 1.3.6.1.4.1.2011.5.25.219.2.35.30 | current |
| hwEntityNpsVmFaultResume NOTIFICATION-TYPE The fault on the VM is cleared. | 1.3.6.1.4.1.2011.5.25.219.2.35.31 | current |
| hwEntityNpsVNFMConnectFault NOTIFICATION-TYPE The connection between VNF and VNFM fault was faulty. | 1.3.6.1.4.1.2011.5.25.219.2.35.32 | current |
| hwEntityNpsVNFMConnectResume NOTIFICATION-TYPE The connection between VNF and VNFM fault was rectified. | 1.3.6.1.4.1.2011.5.25.219.2.35.33 | current |
| hwEntityNpsFabricOamPlaneDown NOTIFICATION-TYPE Fabric plane goes Down. | 1.3.6.1.4.1.2011.5.25.219.2.35.34 | current |
| hwEntityNpsFabricOamPlaneDownResume NOTIFICATION-TYPE Fabric plane down alarm was cleared. | 1.3.6.1.4.1.2011.5.25.219.2.35.35 | current |
| hwEntityNpsFabricLinkSubhealthy NOTIFICATION-TYPE Fabric link goes subhealthy. | 1.3.6.1.4.1.2011.5.25.219.2.35.36 | current |
| hwEntityNpsFabricLinkSubhealthyResume NOTIFICATION-TYPE Fabric link resume from subhealthy. | 1.3.6.1.4.1.2011.5.25.219.2.35.37 | current |
| hwEntityNpsDriverTypeMismatch NOTIFICATION-TYPE Load vNIC driver failure. | 1.3.6.1.4.1.2011.5.25.219.2.35.38 | current |
| hwEntityNpsDriverTypeMismatchResume NOTIFICATION-TYPE Load vNIC driver success. | 1.3.6.1.4.1.2011.5.25.219.2.35.39 | current |
| hwEntityNpsRuCreateFail NOTIFICATION-TYPE The VM create RU failed. | 1.3.6.1.4.1.2011.5.25.219.2.35.40 | current |
| hwEntityNpsRuCreateFailResume NOTIFICATION-TYPE The VM create RU succcess. | 1.3.6.1.4.1.2011.5.25.219.2.35.41 | current |
| hwEntityNpsIpSecRuleFail NOTIFICATION-TYPE Setting Security Group Rules Failed. | 1.3.6.1.4.1.2011.5.25.219.2.35.42 | current |
| hwEntityNpsIpSecRuleFailResume NOTIFICATION-TYPE Setting Security Group Rules Failed alarm clear. | 1.3.6.1.4.1.2011.5.25.219.2.35.43 | current |
| hwEntityNpsBaseLinkSubhealthy NOTIFICATION-TYPE Base link goes subhealthy. | 1.3.6.1.4.1.2011.5.25.219.2.35.44 | current |
| hwEntityNpsBaseLinkSubhealthyResume NOTIFICATION-TYPE Base link resume from subhealthy. | 1.3.6.1.4.1.2011.5.25.219.2.35.45 | current |
| hwEntityConfigurationRollbackRising NOTIFICATION-TYPE An alarm was generated when configuration rollback. | 1.3.6.1.4.1.2011.5.25.219.2.36.1 | current |
| hwNPDomainDropCauseCntNumabruptlyAlarm NOTIFICATION-TYPE The number of key dropcause count on the NP Chip increases abruptly and exceeds the preset threshold. | 1.3.6.1.4.1.2011.5.25.219.2.37.1 | current |
| hwNPDomainDropCauseCntNumabruptlyResume NOTIFICATION-TYPE The number of key dropcause count on the NP Chip return normal . | 1.3.6.1.4.1.2011.5.25.219.2.37.2 | current |
| hwNPResourceExcAlarm NOTIFICATION-TYPE NP Resources abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.38.1 | current |
| hwNPResourceExcResume NOTIFICATION-TYPE NP resources returns to normal. | 1.3.6.1.4.1.2011.5.25.219.2.38.2 | current |
| hwEntityFileSystemRebuild NOTIFICATION-TYPE An alarm was generated when file system rebuild. | 1.3.6.1.4.1.2011.5.25.219.2.39.1 | current |
| hwEntityFileSystemAbnormal NOTIFICATION-TYPE The filesystem is abnormal. | 1.3.6.1.4.1.2011.5.25.219.2.39.2 | current |
| hwEntityCODECHardewareFaultAlarm NOTIFICATION-TYPE CODEC Hardeware Fault. | 1.3.6.1.4.1.2011.5.25.219.2.40.1 | current |
| hwEntityTPMHardewareFaultAlarm NOTIFICATION-TYPE TPM Hardeware Fault. | 1.3.6.1.4.1.2011.5.25.219.2.40.2 | current |
| hwEntityMCUHardewareFaultAlarm NOTIFICATION-TYPE MCU Hardeware Fault. | 1.3.6.1.4.1.2011.5.25.219.2.40.3 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| hwEntityTrapCompliance MODULE-COMPLIANCE Compliance statement for agents that provide full support for hwBaseTrapMIB. | 1.3.6.1.4.1.2011.5.25.219.3.1.1 | current |
| hwEntityObjectGroup OBJECT-GROUP Group for base trap objects. | 1.3.6.1.4.1.2011.5.25.219.3.2.1 | current |
| hwEntityTrapGroup NOTIFICATION-GROUP Group for all base traps. | 1.3.6.1.4.1.2011.5.25.219.3.2.2 | current |