MIBs Depot

HUAWEI-DC-TRAP-MIB

Registered at
1.3.6.1.4.1.2011.5.25.37
Last updated
2006-04-24 00:00
Organization
Huawei Technologies co.,Ltd.
Namespace
huawei
Source file
HUAWEI-DC-TRAP-MIB
Digest
sha256:aadcf5ad9f00e85b239f3d25f5eb050bc68a2b87c91156f486eca2f5d3ef1588

Description

The HUAWEI-DC-TRAP-MIB provides information about DataComm TRAPS.

Contact

R&D BeiJing, Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China Zip:100085 Http://www.huawei.com E-mail:support@huawei.com

Imports

FromSymbols
ENTITY-MIBentPhysicalName
HUAWEI-MIBhwDatacomm
IF-MIBifDescr, ifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
HUAWEI-DC-TRAP-MIB
HUAWEI-MIB
IANA-ENTITY-MIB
IANAifType-MIB
IF-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Objects

NameOIDSyntaxAccessStatus
hwDCTrapControl
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.25.37.1
hwDCCtrlTrap
OBJECT-TYPE
A string serving as a bit map for the trap events defined by the hwDatacomm traps. This object is used to enable and disable specific hwDatacomm traps where a 1 in the bit field represents enabled. The right-most bit (least significant) represents trap 0.
1.3.6.1.4.1.2011.5.25.37.1.1OCTET STRING (SIZE(32))read-writecurrent
hwTunnelGroupID
OBJECT-TYPE
Tunnel id
1.3.6.1.4.1.2011.5.25.37.1.2INTEGER (0..2047)accessible-for-notifycurrent
hwDCTrapReason
OBJECT-TYPE
For the BTB system to report Trap Reason.
1.3.6.1.4.1.2011.5.25.37.1.3DisplayStringaccessible-for-notifycurrent
hwDCTraps
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.25.37.2
hwDCTrapConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.25.37.3
hwDCTrapGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.25.37.3.1
hwDCTrapCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.25.37.3.2

Notifications

NameOIDStatus
hwMPUSynClkFaulty
NOTIFICATION-TYPE
MPU sync clock signal faulty!
1.3.6.1.4.1.2011.5.25.37.2.1current
hwMPUSynClkFaultyResume
NOTIFICATION-TYPE
MPU sync clock signal faulty resume!
1.3.6.1.4.1.2011.5.25.37.2.2current
hwSlaveMPUNoResp
NOTIFICATION-TYPE
Slave MPU has no response!
1.3.6.1.4.1.2011.5.25.37.2.3current
hwSlaveMPUNoRespResume
NOTIFICATION-TYPE
Slave MPU has no response resume!
1.3.6.1.4.1.2011.5.25.37.2.4current
hwBrdChannelFaulty
NOTIFICATION-TYPE
Board channel faulty!
1.3.6.1.4.1.2011.5.25.37.2.5current
hwBrdChannelFaultyResume
NOTIFICATION-TYPE
Board channel faulty resume!
1.3.6.1.4.1.2011.5.25.37.2.6current
hwBrdNofullin
NOTIFICATION-TYPE
Board not full in!
1.3.6.1.4.1.2011.5.25.37.2.7current
hwBrdNofullinResume
NOTIFICATION-TYPE
Board not full in resume!
1.3.6.1.4.1.2011.5.25.37.2.8current
hwBrdTypeNoMatchReset
NOTIFICATION-TYPE
Board is reset because of the chip type is not matching!
1.3.6.1.4.1.2011.5.25.37.2.9current
hwBrdAutoSwtFail
NOTIFICATION-TYPE
Board automatically switch syn-clock but it locked failed!
1.3.6.1.4.1.2011.5.25.37.2.10current
hwBrdAutoSwt
NOTIFICATION-TYPE
Board automatically switch syn-clock!
1.3.6.1.4.1.2011.5.25.37.2.11current
hwBrdClkLockERR
NOTIFICATION-TYPE
Board fabric clock is unlocked!
1.3.6.1.4.1.2011.5.25.37.2.12current
hwBrdClkLockERRResume
NOTIFICATION-TYPE
Board fabric clock unlock to current clock resume!
1.3.6.1.4.1.2011.5.25.37.2.13current
hwBrdRemoved
NOTIFICATION-TYPE
Board pulled out!
1.3.6.1.4.1.2011.5.25.37.2.14current
hwBrdInserted
NOTIFICATION-TYPE
Board plugged in!
1.3.6.1.4.1.2011.5.25.37.2.15current
hwBrdUp
NOTIFICATION-TYPE
Board register!
1.3.6.1.4.1.2011.5.25.37.2.16current
hwClkSrcMiss
NOTIFICATION-TYPE
CLK source Loss Of Signal!
1.3.6.1.4.1.2011.5.25.37.2.17current
hwClkAllSrcLost
NOTIFICATION-TYPE
CLK all source lost!
1.3.6.1.4.1.2011.5.25.37.2.18current
hwClkAllSrcLostResume
NOTIFICATION-TYPE
CLK all source lost resume!
1.3.6.1.4.1.2011.5.25.37.2.19current
hwClkFail
NOTIFICATION-TYPE
CLK hardware failed!
1.3.6.1.4.1.2011.5.25.37.2.20current
hwClkFailResume
NOTIFICATION-TYPE
CLK hardware failed resume!
1.3.6.1.4.1.2011.5.25.37.2.21current
hwClkNoHeartbeat
NOTIFICATION-TYPE
CLK No Heartbeat!
1.3.6.1.4.1.2011.5.25.37.2.22current
hwClkNoHeartbeatResume
NOTIFICATION-TYPE
CLK No Heartbeat resume!
1.3.6.1.4.1.2011.5.25.37.2.23current
hwLPULostSynAlarm
NOTIFICATION-TYPE
LPU SERDES interface is lost synchronization!
1.3.6.1.4.1.2011.5.25.37.2.24current
hwLPUOpenChannelError
NOTIFICATION-TYPE
LPU SERDES interface open error!
1.3.6.1.4.1.2011.5.25.37.2.25current
hwLPUSlfTstErr
NOTIFICATION-TYPE
LPU self test error!
1.3.6.1.4.1.2011.5.25.37.2.26current
hwLPU3ClkSwitch
NOTIFICATION-TYPE
LPU 3 class clock is switch!
1.3.6.1.4.1.2011.5.25.37.2.27current
hwSFULostHrtReset
NOTIFICATION-TYPE
SFU is reset because of heart beat loss!
1.3.6.1.4.1.2011.5.25.37.2.28current
hwSFULinkLostReset
NOTIFICATION-TYPE
SFU is reset because of SERDES interface input channel link lost numbers over threshold!
1.3.6.1.4.1.2011.5.25.37.2.29current
hwSFUChannelLinkLost
NOTIFICATION-TYPE
SFU check SERDES interface input channel link lost!
1.3.6.1.4.1.2011.5.25.37.2.30current
hwSFUInChannelOpenFail
NOTIFICATION-TYPE
SFU SERDES interface input channel is opened failed!
1.3.6.1.4.1.2011.5.25.37.2.31current
hwVoltSensorFail
NOTIFICATION-TYPE
Board voltage monitor failure!
1.3.6.1.4.1.2011.5.25.37.2.32current
hwVoltSensorFailResume
NOTIFICATION-TYPE
Board voltage monitor failure resume!
1.3.6.1.4.1.2011.5.25.37.2.33current
hwVoltBtmC
NOTIFICATION-TYPE
Board voltage below fatal threshold!
1.3.6.1.4.1.2011.5.25.37.2.34current
hwVoltBtmCResume
NOTIFICATION-TYPE
Board voltage below fatal threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.35current
hwVoltSprC
NOTIFICATION-TYPE
Board voltage over fatal threshold!
1.3.6.1.4.1.2011.5.25.37.2.36current
hwVoltSprCResume
NOTIFICATION-TYPE
Board voltage over fatal threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.37current
hwVoltBtmM
NOTIFICATION-TYPE
Board voltage below major threshold!
1.3.6.1.4.1.2011.5.25.37.2.38current
hwVoltBtmMResume
NOTIFICATION-TYPE
Board voltage below major threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.39current
hwVoltSprM
NOTIFICATION-TYPE
Board voltage over major threshold!
1.3.6.1.4.1.2011.5.25.37.2.40current
hwVoltSprMResume
NOTIFICATION-TYPE
Board voltage over major threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.41current
hwTempSensorFail
NOTIFICATION-TYPE
Board temprature monitor failure!
1.3.6.1.4.1.2011.5.25.37.2.42current
hwTempSensorFailResume
NOTIFICATION-TYPE
Board temperature monitor failure resume!
1.3.6.1.4.1.2011.5.25.37.2.43current
hwTempMnr
NOTIFICATION-TYPE
Board temperature over minor threshold!
1.3.6.1.4.1.2011.5.25.37.2.44current
hwTempMnrResume
NOTIFICATION-TYPE
Board temperature over minor threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.45current
hwTempMjr
NOTIFICATION-TYPE
Board temperature over major threshold!
1.3.6.1.4.1.2011.5.25.37.2.46current
hwTempMjrResume
NOTIFICATION-TYPE
Board temperature over major threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.47current
hwTempCtl
NOTIFICATION-TYPE
Board temperature over fatal threshold!
1.3.6.1.4.1.2011.5.25.37.2.48current
hwTempCtlResume
NOTIFICATION-TYPE
Board temperature over fatal threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.49current
hwFanHFail
NOTIFICATION-TYPE
Fan hardware failure!
1.3.6.1.4.1.2011.5.25.37.2.50current
hwFanFail
NOTIFICATION-TYPE
Fan failure!
1.3.6.1.4.1.2011.5.25.37.2.51current
hwFanFailResume
NOTIFICATION-TYPE
Fan failure resume!
1.3.6.1.4.1.2011.5.25.37.2.52current
hwFanAbsent
NOTIFICATION-TYPE
Fan absent!
1.3.6.1.4.1.2011.5.25.37.2.53current
hwFanAbsentResume
NOTIFICATION-TYPE
Fan absent resume!
1.3.6.1.4.1.2011.5.25.37.2.54current
hwFanCabUN
NOTIFICATION-TYPE
Fan cable unplugged!
1.3.6.1.4.1.2011.5.25.37.2.55current
hwFanCabUNResume
NOTIFICATION-TYPE
Fan cable unplugged resume!
1.3.6.1.4.1.2011.5.25.37.2.56current
hwPwrFail
NOTIFICATION-TYPE
Power failure!
1.3.6.1.4.1.2011.5.25.37.2.57current
hwPwrFailResume
NOTIFICATION-TYPE
Power failure resume!
1.3.6.1.4.1.2011.5.25.37.2.58current
hwPwrAbsent
NOTIFICATION-TYPE
Power absent!
1.3.6.1.4.1.2011.5.25.37.2.59current
hwPwrAbsentResume
NOTIFICATION-TYPE
Power absent resume!
1.3.6.1.4.1.2011.5.25.37.2.60current
hwPwrCabUN
NOTIFICATION-TYPE
Power monitor cable unplugged!
1.3.6.1.4.1.2011.5.25.37.2.61current
hwPwrCabUNResume
NOTIFICATION-TYPE
Power monitor cable unplugged resume!
1.3.6.1.4.1.2011.5.25.37.2.62current
hwLCDHFail
NOTIFICATION-TYPE
LCD hardware failure!
1.3.6.1.4.1.2011.5.25.37.2.63current
hwLCDFail
NOTIFICATION-TYPE
LCD failure!
1.3.6.1.4.1.2011.5.25.37.2.64current
hwLCDAbsent
NOTIFICATION-TYPE
LCD absent!
1.3.6.1.4.1.2011.5.25.37.2.65current
hwLCDAbsentResume
NOTIFICATION-TYPE
LCD absent resume!
1.3.6.1.4.1.2011.5.25.37.2.66current
hwLCDCabUN
NOTIFICATION-TYPE
LCD cable unplugged!
1.3.6.1.4.1.2011.5.25.37.2.67current
hwLCDCabUNResume
NOTIFICATION-TYPE
LCD cable unplugged resume!
1.3.6.1.4.1.2011.5.25.37.2.68current
hwROMFail
NOTIFICATION-TYPE
EEPROM failure!
1.3.6.1.4.1.2011.5.25.37.2.69current
hwMonitorBUSFail
NOTIFICATION-TYPE
MonitorBUS failure!
1.3.6.1.4.1.2011.5.25.37.2.70current
hwMonitorBUSFailResume
NOTIFICATION-TYPE
MonitorBUS failure resume!
1.3.6.1.4.1.2011.5.25.37.2.71current
hwBoardOfflineChange
NOTIFICATION-TYPE
Board power status change!
1.3.6.1.4.1.2011.5.25.37.2.72current
hwWriteFlashError
NOTIFICATION-TYPE
write flash error!
1.3.6.1.4.1.2011.5.25.37.2.100current
hwBoardReset
NOTIFICATION-TYPE
board reset!
1.3.6.1.4.1.2011.5.25.37.2.101current
hwBoardResetSuccess
NOTIFICATION-TYPE
board reset success!
1.3.6.1.4.1.2011.5.25.37.2.102current
hwSlaveMPUReset
NOTIFICATION-TYPE
slave MPU reset !
1.3.6.1.4.1.2011.5.25.37.2.103current
hwMasterSlaveSwap
NOTIFICATION-TYPE
master slave swap!
1.3.6.1.4.1.2011.5.25.37.2.104current
hwRTCFail
NOTIFICATION-TYPE
RTC failure!
1.3.6.1.4.1.2011.5.25.37.2.105current
hwExchangeChipFail
NOTIFICATION-TYPE
5695 exchange chip fail!
1.3.6.1.4.1.2011.5.25.37.2.106current
hwTempResume
NOTIFICATION-TYPE
Board temprature over threshold resume!
1.3.6.1.4.1.2011.5.25.37.2.107current
hwOpticalModuleInsert
NOTIFICATION-TYPE
optical module plug in !
1.3.6.1.4.1.2011.5.25.37.2.108current
hwOpticalModuleRemove
NOTIFICATION-TYPE
optical module plug out !
1.3.6.1.4.1.2011.5.25.37.2.109current
hwFPGAAbnormal
NOTIFICATION-TYPE
FPGA abnormal !
1.3.6.1.4.1.2011.5.25.37.2.110current
hwMinMTunnelDownAlarm
NOTIFICATION-TYPE
For Mac in Mac tunnel. Mac tunnel have two status: up or down, when physical interface is down or some cc package can't arrive to the other side of mac in mac tunnel, the status of tunnel will be down 1 Notice/Trap name: Tunnel down 2 Notice/Trap generation cause: when All mac tunnel have been down in the mac tunnel group 3 Repair suggestions: make one of the mac tunnel up in the mac tunnel group
1.3.6.1.4.1.2011.5.25.37.2.111current
hwMinMTunnelUpAlarm
NOTIFICATION-TYPE
For Mac in Mac tunnel. Mac tunnel have two status: up or down, if cc package can arrive to the other side of mac in mac tunnel, the status of tunnel will be up 1 Notice/Trap name: Tunnel up 2 Notice/Trap generation cause: one of the tunnel is up in the mac tunnel group 3 Repair suggestion:
1.3.6.1.4.1.2011.5.25.37.2.112current
hwInterfacePhysicalDown
NOTIFICATION-TYPE
This trap is to indicate port link down on physical layer.
1.3.6.1.4.1.2011.5.25.37.2.113current
hwInterfacePhysicalUp
NOTIFICATION-TYPE
This trap is to indicate port link up on physical layer.
1.3.6.1.4.1.2011.5.25.37.2.114current
hwBTBStartupFileNameDifferent
NOTIFICATION-TYPE
In the BTB system ,the start-up file name of master and slave chassis is different . Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.119current
hwBTBChassisRunningModeConflict
NOTIFICATION-TYPE
The Master and Slave chassises running modes conflict.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.120current
hwBTBCtrlChannelFail
NOTIFICATION-TYPE
The FE control channel failture, as physical link from up to down or channel blocked. Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.121current
hwBTBCtrlChannelFailResume
NOTIFICATION-TYPE
The FE control channel failture resume.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.122current
hwBTBDataChannelFail
NOTIFICATION-TYPE
The data channel failture, all optical links down between chassises.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.123current
hwBTBDataChannelFailResume
NOTIFICATION-TYPE
The data channel failture resume.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.124current
hwBTBClkChannelFail
NOTIFICATION-TYPE
The clock channel failture, clock link down between chassises.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.125current
hwBTBClkChannelFailResume
NOTIFICATION-TYPE
The clock Channel failture resume.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.126current
hwBTBSFUOpticInterfaceError
NOTIFICATION-TYPE
The optical fiber connection error, the connection of SFU fiber between chassises is not correct. Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.127current
hwBTBSFUOpticInterfaceErrorResume
NOTIFICATION-TYPE
The optical fiber connection error resume.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.128current
hwBTBVSRInterfaceInvalid
NOTIFICATION-TYPE
The SFU VSR(very short reach) interface invalid.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.129current
hwBTBVSRInterfaceInvalidResume
NOTIFICATION-TYPE
The SFU VSR(very short reach) interface invalid resume.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.130current
hwBTBSlaveChassisNoHeart
NOTIFICATION-TYPE
The slave chassis no heart.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.131current
hwBTBNoSlaveChassis
NOTIFICATION-TYPE
No slave chassis connected to the master chassis in the BTB system.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.132current
hwBTBSlaveChassisRegisted
NOTIFICATION-TYPE
The slave chassis registe successful.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.133current
hwBTBSlaveChassisRegisteFail
NOTIFICATION-TYPE
The slave chassis registe failed.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.134current
hwBTBChassisTypeConflict
NOTIFICATION-TYPE
The chassis information conflict in the PAF and Nvram.Used for BTB or its extend system.
1.3.6.1.4.1.2011.5.25.37.2.135current
hwSuperChangeSuccesful
NOTIFICATION-TYPE
Super change successful.
1.3.6.1.4.1.2011.5.25.37.2.136current
hwSuperChangeFailure
NOTIFICATION-TYPE
Super change Failure.
1.3.6.1.4.1.2011.5.25.37.2.137current
hwOpticaPowerAbnormal
NOTIFICATION-TYPE
Optical Transceiver power abnormal.
1.3.6.1.4.1.2011.5.25.37.2.138current
hwEpldAbnormal
NOTIFICATION-TYPE
Epld logic abnormal.
1.3.6.1.4.1.2011.5.25.37.2.139current
hwPhyChipAbnormal
NOTIFICATION-TYPE
PHY chip is abnormal.
1.3.6.1.4.1.2011.5.25.37.2.140current
hwSerdesAbnormal
NOTIFICATION-TYPE
Serdes interface of PHY chip abnormal.
1.3.6.1.4.1.2011.5.25.37.2.141current
hwBoardAbnormal
NOTIFICATION-TYPE
Board is abnormal.
1.3.6.1.4.1.2011.5.25.37.2.142current
hwFeChannelAbnormal
NOTIFICATION-TYPE
FE data channel is abnormal
1.3.6.1.4.1.2011.5.25.37.2.143current
hwParityCheckAbnormal
NOTIFICATION-TYPE
Data parity check is abnormal
1.3.6.1.4.1.2011.5.25.37.2.144current
hwPhyClockAbnormal
NOTIFICATION-TYPE
The clock of PHY chip is abnormal.
1.3.6.1.4.1.2011.5.25.37.2.145current
hwPortAutoNegotiateFail
NOTIFICATION-TYPE
The ethernet port negotiate failed
1.3.6.1.4.1.2011.5.25.37.2.146current
hwPortSemiduplex
NOTIFICATION-TYPE
The ethernet port work at semi duplex state.
1.3.6.1.4.1.2011.5.25.37.2.147current
hwScuStartModeSetFail
NOTIFICATION-TYPE
The start mode of SCU set failed
1.3.6.1.4.1.2011.5.25.37.2.148current
hwMemoryExhaust
NOTIFICATION-TYPE
MPU memory exhaust.
1.3.6.1.4.1.2011.5.25.37.2.149current
hwMemoryExhaustClear
NOTIFICATION-TYPE
MPU memory usage resume to normal.
1.3.6.1.4.1.2011.5.25.37.2.150current
hwMethAbnormal
NOTIFICATION-TYPE
The Meth interface is abnormal.
1.3.6.1.4.1.2011.5.25.37.2.151current
hwLpuNotTight
NOTIFICATION-TYPE
The LPU board is not tightly installed. Install the board again.
1.3.6.1.4.1.2011.5.25.37.2.152current
hwLicenseFail
NOTIFICATION-TYPE
License fail.
1.3.6.1.4.1.2011.5.25.37.2.153current
hwHaBatchBegin
NOTIFICATION-TYPE
No command line can be entered because batch backup is processing.
1.3.6.1.4.1.2011.5.25.37.2.154current
hwHaBatchEnd
NOTIFICATION-TYPE
Command lines can be entered because batch backup ends.
1.3.6.1.4.1.2011.5.25.37.2.155current
hwHaSmoothBegin
NOTIFICATION-TYPE
No command line can be entered because data smooth is processing.
1.3.6.1.4.1.2011.5.25.37.2.156current
hwHaSmoothEnd
NOTIFICATION-TYPE
Command lines can be entered because data smooth ends.
1.3.6.1.4.1.2011.5.25.37.2.157current

Conformance

NameOIDStatus
hwDCTrapControlGroup
OBJECT-GROUP
These objects are required to control traps from hwDatacomm Traps systems.
1.3.6.1.4.1.2011.5.25.37.3.1.1current
hwDCNotificationGroup
NOTIFICATION-GROUP
The notification group defined for Datacomm products.
1.3.6.1.4.1.2011.5.25.37.3.1.2current
hwDCTrapCompliance
MODULE-COMPLIANCE
The compliance statement.
1.3.6.1.4.1.2011.5.25.37.3.2.1current