MIBs Depot

HMLLDP-MIB

Registered at
1.3.6.1.4.1.248.14.7
Last updated
2004-11-22 00:00
Organization
Hirschmann Automation and Control GmbH
Revisions
2004-11-22 00:00
Namespace
hirschmann
Source file
HMLLDP-MIB
Digest
sha256:331dac6ade95eeb685a70eba1892361f3efa5c3df52b60f0d07b095afbb3a8ea

Description

The Hirschmann Private LLDP MIB definitions for Platform devices.

Contact

Customer Support Postal: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel: +49 7127 14 1981 Web: http://www.hicomcenter.com/ E-Mail: hicomcenter@hirschmann.com

Imports

FromSymbols
HMPRIV-MGMT-SNMP-MIBhmConfiguration
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BRIDGE-MIB
HMLLDP-MIB
HMPRIV-MGMT-SNMP-MIB
IANA-ADDRESS-FAMILY-NUMBERS-MIB
IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB

Objects

NameOIDSyntaxAccessStatus
hmLLDPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.248.14.7.1
hmLLDPAdminStatus
OBJECT-TYPE
DURABLE: Enables/disables the IEEE802.1AB functionality on this device. If disabled(2), the LLDP protocol is inactive, but the LLDP MIBs can be accessed.
1.3.6.1.4.1.248.14.7.1.1INTEGER {enable(1), disable(2)}read-writecurrent
hmLLDPInterfaceTable
OBJECT-TYPE
This table contains variables for each interface of the switch.
1.3.6.1.4.1.248.14.7.1.2not-accessiblecurrent
hmLLDPIfEntry
OBJECT-TYPE
The entry of the hmLLDPInterfaceTable.
1.3.6.1.4.1.248.14.7.1.2.1not-accessiblecurrent
hmLLDPIfaceGroupID
OBJECT-TYPE
index to identify an interface card. This value is never greater than hmSysGroupCapacity.
1.3.6.1.4.1.248.14.7.1.2.1.1Integer32 (1..5)read-onlycurrent
hmLLDPIfaceID
OBJECT-TYPE
index to identify an interface within an interface card.
1.3.6.1.4.1.248.14.7.1.2.1.2Integer32 (1..128)read-onlycurrent
hmLLDPIfaceHirmaMode
OBJECT-TYPE
Configure Hirschmann LLDP on this physical port. If an IEEE802.1AB capable device not manufactured by Hirschmann is connected to a port, hmLLDPIfaceHirmaMode should be set to disabled (4) for this port.
1.3.6.1.4.1.248.14.7.1.2.1.3INTEGER {txOnly(1), rxOnly(2), txAndRx(3), disabled(4)}read-writecurrent
hmLLDPIfaceFDBMode
OBJECT-TYPE
If configured to lldpOnly(1), only received LLDP messages will be used to populate the LLDP-MIB's remTable. If configured to macOnly(2), learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to both(3), both received LLDP messages and learned mac addresses out of the switch's forwarding database (FDB) will be used to populate the LLDP-MIB's remTable. If configured to autoDetect(4) and LLDP messages are received on this port, this mode will behave like lldpOnly(1), otherwise it will behave like macOnly(2).
1.3.6.1.4.1.248.14.7.1.2.1.4INTEGER {lldpOnly(1), macOnly(2), both(3), autoDetect(4)}read-writecurrent
hmLLDPIfaceMaxNeighbors
OBJECT-TYPE
Configure Hirschmann LLDP on this physical port. This value limits the number of entries in the remTable for this port.
1.3.6.1.4.1.248.14.7.1.2.1.5Integer32 (1..50)read-writecurrent
hmLLDPStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.248.14.7.2
hmLLDPStatsIfTable
OBJECT-TYPE
This table contains variables for each interface of the switch.
1.3.6.1.4.1.248.14.7.2.1not-accessiblecurrent
hmLLDPStatsIfEntry
OBJECT-TYPE
The entry of the hmLLDPStatsIfTable.
1.3.6.1.4.1.248.14.7.2.1.1not-accessiblecurrent
hmLLDPStatsIfaceGroupID
OBJECT-TYPE
index to identify an interface card. This value is never greater than hmSysGroupCapacity.
1.3.6.1.4.1.248.14.7.2.1.1.1Integer32 (1..5)read-onlycurrent
hmLLDPStatsIfaceID
OBJECT-TYPE
index to identify an interface within an interface card.
1.3.6.1.4.1.248.14.7.2.1.1.2Integer32 (1..32)read-onlycurrent
hmLLDPStatsIfaceTotalFDBEntryCount
OBJECT-TYPE
The total number of learned entries in the forwarding database (FDB) for this port.
1.3.6.1.4.1.248.14.7.2.1.1.3Counter32read-onlycurrent
hmLLDPStatsIfaceTotalEntryCount
OBJECT-TYPE
The total number of remote connections in the LLDP MIB's remTable for this port.
1.3.6.1.4.1.248.14.7.2.1.1.4Counter32read-onlycurrent
hmLLDPStatsIfaceIEEEEntryCount
OBJECT-TYPE
The number of remote connections in the LLDP MIB's remTable for this port that were detected because an LLDP message from an IEEE source was received.
1.3.6.1.4.1.248.14.7.2.1.1.5Counter32read-onlycurrent
hmLLDPStatsIfaceHirmaEntryCount
OBJECT-TYPE
The number of remote connections in the LLDP MIB's remTable for this port that were detected because an LLDP message from an Hirschmann source was received.
1.3.6.1.4.1.248.14.7.2.1.1.6Counter32read-onlycurrent
hmLLDPStatsIfaceFDBEntryCount
OBJECT-TYPE
The number of remote connections in the LLDP MIB's remTable for this port that were detected in the forwarding database (FDB) for this port.
1.3.6.1.4.1.248.14.7.2.1.1.7Counter32read-onlycurrent