Description

The objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification.

Contact

SMB EOC Team New H3C Technologies Co., Ltd. Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:310053.

Imports

FromSymbols
HH3C-OID-MIBhh3cCommon
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HH3C-HPEOC-MIB
HH3C-OID-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hh3cHPEOCSystem
OBJECT-IDENTITY
1.3.6.1.4.1.25506.2.84.1
hh3cHPEOCCltVlanType
OBJECT-TYPE
Control EOC CLT's VLAN type, ieee8021q : 802.1q VLAN mode, portbased : portbased VLAN mode.
1.3.6.1.4.1.25506.2.84.1.1INTEGER {ieee8021q(1), portbased(2)}read-writecurrent
hh3cHPEOCCltVlanManTable
OBJECT-TYPE
This table implements the management of CLT(Coax Line Terminal) VLAN.
1.3.6.1.4.1.25506.2.84.1.2not-accessiblecurrent
hh3cHPEOCCltVlanManEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCCltVlanManTable.
1.3.6.1.4.1.25506.2.84.1.2.1not-accessiblecurrent
hh3cHPEOCCltEthPortType
OBJECT-TYPE
Control CLT ethernet ports' type, normal : port which used for normal translation, debug : port which used for debug.
1.3.6.1.4.1.25506.2.84.1.2.1.1INTEGER {normal(1), debug(2)}read-writecurrent
hh3cHPEOCCltSysManTable
OBJECT-TYPE
This table implements the management of CLT(Coax Line Terminal).
1.3.6.1.4.1.25506.2.84.1.3not-accessiblecurrent
hh3cHPEOCCltSysManEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCCltSysManTable.
1.3.6.1.4.1.25506.2.84.1.3.1not-accessiblecurrent
hh3cHPEOCCltDescr
OBJECT-TYPE
Set the description of CLT.
1.3.6.1.4.1.25506.2.84.1.3.1.1DisplayString (SIZE(0..126))read-writecurrent
hh3cHPEOCCltFwVersion
OBJECT-TYPE
EOC firmware version. If the object length is zero, it means the version is unknown.
1.3.6.1.4.1.25506.2.84.1.3.1.2DisplayStringread-onlycurrent
hh3cHPEOCCltLinkState
OBJECT-TYPE
The cable port's link state. The physicaldown(1) state indicates that the CLT is not powered on. The linkdown(2) state indicates that the CLT is powered on, but registers fail. The linkup(3) state indicates that the CLT is powered on, and registers successful. The loopback(4) state indecates that the CLT is powered on and registers successful, but loopback has detected.
1.3.6.1.4.1.25506.2.84.1.3.1.3INTEGER {physicaldown(1), linkdown(2), linkup(3), loopback(4)}read-onlycurrent
hh3cHPEOCCnuSysManTable
OBJECT-TYPE
This table implements the management of CNUs.
1.3.6.1.4.1.25506.2.84.1.4not-accessiblecurrent
hh3cHPEOCCnuSysManEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCCnuSysManTable.
1.3.6.1.4.1.25506.2.84.1.4.1not-accessiblecurrent
hh3cHPEOCCnuBcastControl
OBJECT-TYPE
Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.
1.3.6.1.4.1.25506.2.84.1.4.1.1TruthValueread-writecurrent
hh3cHPEOCCnuAnonymStatus
OBJECT-TYPE
Anonymity status. true(1) - the user which uses the CNU is anonymous. false(2) - the user which uses the CNU has an account.
1.3.6.1.4.1.25506.2.84.1.4.1.2TruthValueread-onlycurrent
hh3cHPEOCCnuMacLimit
OBJECT-TYPE
Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU.
1.3.6.1.4.1.25506.2.84.1.4.1.3Unsigned32read-writecurrent
hh3cHPEOCCltAutoUpgrade
OBJECT-TYPE
Auto upgrade Status. true(1) - The firmware of the CNU will be auto changed by CLT. false(2)- The firmware of the CNU will not be auto changed.
1.3.6.1.4.1.25506.2.84.1.5TruthValueread-writecurrent
hh3cHPEOCOnLineCnuNumber
OBJECT-TYPE
The total number of the online CNU(s).
1.3.6.1.4.1.25506.2.84.1.6Integer32read-onlycurrent
hh3cHPEOCCpuMacAddress
OBJECT-TYPE
EOC CPU's MAC address.
1.3.6.1.4.1.25506.2.84.1.7MacAddressread-onlycurrent
hh3cHPEOCOffLineCnuNumber
OBJECT-TYPE
The total number of the offline CNU(s).
1.3.6.1.4.1.25506.2.84.1.8Integer32read-onlycurrent
hh3cHPEOCDownLoadCNUFWResult
OBJECT-TYPE
Download CNU firmware result.
1.3.6.1.4.1.25506.2.84.1.9DisplayStringaccessible-for-notifycurrent
hh3cHPEOCCltAutoUpgradeType
OBJECT-TYPE
Type of auto upgrade status. It depends on hh3cHPEOCCltAutoUpgrade status. flash - The CLT auto upgrade the firmware inside its flash to the CNUs. ftp - First download the firmware from FTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs. tftp - First download the firmware from TFTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs.
1.3.6.1.4.1.25506.2.84.1.10INTEGER {flash(1), ftp(2), tftp(3)}read-writecurrent
hh3cHPEOCAutoUpObjects
OBJECT-IDENTITY
1.3.6.1.4.1.25506.2.84.1.11
hh3cHPEOCServerAddress
OBJECT-TYPE
The address of remote host acting as server for operation. The default value is 0.0.0.0
1.3.6.1.4.1.25506.2.84.1.11.1IpAddressread-writecurrent
hh3cHPEOCServerUser
OBJECT-TYPE
When using ftp to transfer files, the user name must be specified through this node. It contains 1 to 30 characters.
1.3.6.1.4.1.25506.2.84.1.11.2DisplayStringread-writecurrent
hh3cHPEOCServerPassword
OBJECT-TYPE
Remote user password for copying via ftp protocol. Optionally, this object may be ignored for protocols other than ftp. It contains 1 to 31 characters.
1.3.6.1.4.1.25506.2.84.1.11.3DisplayStringread-writecurrent
hh3cHPEOCCltLoopbackDetect
OBJECT-TYPE
Loopback detect Status. true(1) - The loopback detect is enabled. false(0)- The loopback detect is disabled.
1.3.6.1.4.1.25506.2.84.1.12INTEGER {false(0), true(1)}read-writecurrent
hh3cHPEOCTemplateEnable
OBJECT-TYPE
Use template for white-list cnu. true(1) - Use template is enabled. false(0)- Use template detect is disabled.
1.3.6.1.4.1.25506.2.84.1.13INTEGER {false(0), true(1)}read-writecurrent
hh3cHPEOCCableInfo
OBJECT-IDENTITY
1.3.6.1.4.1.25506.2.84.2
hh3cHPEOCCableInfoTable
OBJECT-TYPE
This table defines the primary parameters of the cable information.
1.3.6.1.4.1.25506.2.84.2.1not-accessiblecurrent
hh3cHPEOCCableInfoEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCCableInfoTable.
1.3.6.1.4.1.25506.2.84.2.1.1not-accessiblecurrent
hh3cHPEOCFECErrors
OBJECT-TYPE
The cable port's FEC bits errors ratio. FEC means the payload Forward Error Correction. It's a technology of controlling errors. Packets in transmission is checked by the receiver, if error occurs, the receiver will announce the sender to resend.
1.3.6.1.4.1.25506.2.84.2.1.1.1Counter64read-onlycurrent
hh3cHPEOCAvgBitsPerCarrier
OBJECT-TYPE
The cable port's average bits per carrier.
1.3.6.1.4.1.25506.2.84.2.1.1.2Unsigned32read-onlycurrent
hh3cHPEOCAvgSNRPerCarrier
OBJECT-TYPE
The cable port's signal noise ratio(SNR) bits per carrier.
1.3.6.1.4.1.25506.2.84.2.1.1.3Integer32read-onlycurrent
hh3cHPEOCAvgInPBCRCErrors
OBJECT-TYPE
The input PB CRC errors on average.
1.3.6.1.4.1.25506.2.84.2.1.1.4Unsigned32read-onlycurrent
hh3cHPEOCInTotalPkts
OBJECT-TYPE
The total number of packets(including bad packets) received on this interface.
1.3.6.1.4.1.25506.2.84.2.1.1.5Counter64read-onlycurrent
hh3cHPEOCAvgOutPower
OBJECT-TYPE
The cable port's power sent on average, the unit is db.
1.3.6.1.4.1.25506.2.84.2.1.1.6Integer32read-onlycurrent
hh3cHPEOCAvgOutPBCRCErrors
OBJECT-TYPE
The cable port's physical block(PB) cyclic redundancy check(CRC) errors sent on average.
1.3.6.1.4.1.25506.2.84.2.1.1.7Unsigned32read-onlycurrent
hh3cHPEOCOutTotalPkts
OBJECT-TYPE
The total count of the packets(including bad packets) sent on this interface.
1.3.6.1.4.1.25506.2.84.2.1.1.8Counter64read-onlycurrent
hh3cHPEOCBitPerSymbolTable
OBJECT-TYPE
This table defines the bits per symbol parameters of the cable line.
1.3.6.1.4.1.25506.2.84.2.2not-accessiblecurrent
hh3cHPEOCBitPerSymbolEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCBitPerSymbolTable.
1.3.6.1.4.1.25506.2.84.2.2.1not-accessiblecurrent
hh3cHPEOCBitPerSymbolIndex
OBJECT-TYPE
The index of the hh3cHPEOCBitPerSymbolTable.
1.3.6.1.4.1.25506.2.84.2.2.1.1Unsigned32not-accessiblecurrent
hh3cHPEOCBitPerSymbol
OBJECT-TYPE
hh3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed frequency. Each 4 bits stand for one value, all the values picking-up will make up a cable bit map.
1.3.6.1.4.1.25506.2.84.2.2.1.2OCTET STRINGread-onlycurrent
hh3cHPEOCTemplate
OBJECT-IDENTITY
1.3.6.1.4.1.25506.2.84.3
hh3cHPEOCTemplateGlobalTable
OBJECT-TYPE
This table defines the global parameters of the Template information.
1.3.6.1.4.1.25506.2.84.3.1not-accessiblecurrent
hh3cHPEOCTemplateGlobalEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCTemplateGlobalTable.
1.3.6.1.4.1.25506.2.84.3.1.1not-accessiblecurrent
hh3cHPEOCTemplateIndex
OBJECT-TYPE
The index of cable Template.
1.3.6.1.4.1.25506.2.84.3.1.1.1Integer32read-createcurrent
hh3cHPEOCTemplateType
OBJECT-TYPE
The cable Template's type, can not change after create it.
1.3.6.1.4.1.25506.2.84.3.1.1.2INTEGER {switch(1), gateway(2)}read-createcurrent
hh3cHPEOCTemplateName
OBJECT-TYPE
The cable Template's name, it's recommended to set it uniquely and understandably. Length: 1 to 15 characters.
1.3.6.1.4.1.25506.2.84.3.1.1.3DisplayStringread-writecurrent
hh3cHPEOCTemplateDescr
OBJECT-TYPE
The cable Template's description. Length: 0 to 63 characters.
1.3.6.1.4.1.25506.2.84.3.1.1.4DisplayStringread-writecurrent
hh3cHPEOCTemplateCnuMaxDownBW
OBJECT-TYPE
Maximum downstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
1.3.6.1.4.1.25506.2.84.3.1.1.5Integer32read-writecurrent
hh3cHPEOCTemplateCnuMaxUpBW
OBJECT-TYPE
Maximum upstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
1.3.6.1.4.1.25506.2.84.3.1.1.6Integer32read-writecurrent
hh3cHPEOCTemplateCnuBcastControl
OBJECT-TYPE
Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.
1.3.6.1.4.1.25506.2.84.3.1.1.7TruthValueread-writecurrent
hh3cHPEOCTemplateCnuMacLimit
OBJECT-TYPE
Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU.
1.3.6.1.4.1.25506.2.84.3.1.1.8Unsigned32read-writecurrent
hh3cHPEOCTemplateCb201VlanEn
OBJECT-TYPE
Use for Cb201 cnu only. true(1) - Enable vlan insert function. false(2) - Disable vlan insert function.
1.3.6.1.4.1.25506.2.84.3.1.1.9TruthValueread-writecurrent
hh3cHPEOCTemplateRowStatus
OBJECT-TYPE
Operation status.
1.3.6.1.4.1.25506.2.84.3.1.1.10RowStatusread-createcurrent
hh3cHPEOCTemplateSwitchTable
OBJECT-TYPE
This table defines the port parameters of the switch type cnu. it's not affect on the type of gateway Template.
1.3.6.1.4.1.25506.2.84.3.2not-accessiblecurrent
hh3cHPEOCTemplateSwitchEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCTemplateSwitchTable.
1.3.6.1.4.1.25506.2.84.3.2.1not-accessiblecurrent
hh3cHPEOCTemplateUniIndex
OBJECT-TYPE
The index value which uniquely identifies the FE interface of the CNU.
1.3.6.1.4.1.25506.2.84.3.2.1.1Integer32not-accessiblecurrent
hh3cHPEOCTemplateUniSpeed
OBJECT-TYPE
User network interface speed.
1.3.6.1.4.1.25506.2.84.3.2.1.2INTEGER {auto(1), s10M(10), s100M(100)}read-writecurrent
hh3cHPEOCTemplateUniDuplex
OBJECT-TYPE
User network interface mode.
1.3.6.1.4.1.25506.2.84.3.2.1.3INTEGER {full(1), half(2), auto(3)}read-writecurrent
hh3cHPEOCTemplateUniPriority
OBJECT-TYPE
The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority.
1.3.6.1.4.1.25506.2.84.3.2.1.4Integer32 (0..7)read-writecurrent
hh3cHPEOCTemplateUniFlowControl
OBJECT-TYPE
Flow control status. true(1) - Flow control status enable. false(2) - Flow control status disable.
1.3.6.1.4.1.25506.2.84.3.2.1.5TruthValueread-writecurrent
hh3cHPEOCTemplateUniUpLineRate
OBJECT-TYPE
The max speed upload in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the upload speed is only restricted by the physical line.
1.3.6.1.4.1.25506.2.84.3.2.1.6Unsigned32read-writecurrent
hh3cHPEOCTemplateUniDownLineRate
OBJECT-TYPE
The max speed download in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the download speed is only restricted by the physical line.
1.3.6.1.4.1.25506.2.84.3.2.1.7Unsigned32read-writecurrent
hh3cHPEOCTemplateUniAdminStatus
OBJECT-TYPE
Control if open or close the UNI. If choose up(1), means the UNI is opened and packets can pass it. If choose down(2), means the UNI is closed and all packets will be discard.
1.3.6.1.4.1.25506.2.84.3.2.1.8INTEGER {up(1), down(2)}read-writecurrent
hh3cHPEOCTemplateUniVLANType
OBJECT-TYPE
port vlan types. hybrid (3) port can carry multiple VLANs.
1.3.6.1.4.1.25506.2.84.3.2.1.9INTEGER {access(1), trunk(2), hybrid(3)}read-writecurrent
hh3cHPEOCTemplateUniPvid
OBJECT-TYPE
The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on this port.
1.3.6.1.4.1.25506.2.84.3.2.1.10Integer32 (1..4094)read-writecurrent
hh3cHPEOCTemplateUniVlanTag
OBJECT-TYPE
VLAN is set tagged or untagged.
1.3.6.1.4.1.25506.2.84.3.2.1.11INTEGER {tagged(1), untagged(2)}read-writecurrent
hh3cHPEOCCnuAccess
OBJECT-IDENTITY
1.3.6.1.4.1.25506.2.84.4
hh3cHPEOCCnuAccessTable
OBJECT-TYPE
This table defines the global parameters of the cnu type permitting to access.
1.3.6.1.4.1.25506.2.84.4.1not-accessiblecurrent
hh3cHPEOCCnuAccessEntry
OBJECT-TYPE
The entry of the table hh3cHPEOCCnuAccessTable.
1.3.6.1.4.1.25506.2.84.4.1.1not-accessiblecurrent
hh3cHPEOCCnuAccessIndex
OBJECT-TYPE
The index value which uniquely identifies the manuinfo of the CNU.
1.3.6.1.4.1.25506.2.84.4.1.1.1Integer32read-createcurrent
hh3cHPEOCCnuHFID
OBJECT-TYPE
The Cnu's HFID. Every type Cnu has it's unique HFID. Length: 1 to 64 characters.
1.3.6.1.4.1.25506.2.84.4.1.1.2DisplayStringread-writecurrent
hh3cHPEOCManuInfo
OBJECT-TYPE
The Cnu's manufactory infofamiont. Length: 0 to 63 characters.
1.3.6.1.4.1.25506.2.84.4.1.1.3DisplayStringread-writecurrent
hh3cHPEOCCnuType
OBJECT-TYPE
The Cnu's function type.
1.3.6.1.4.1.25506.2.84.4.1.1.4INTEGER {switch(1), gateway(2)}read-writecurrent
hh3cHPEOCCnuSwitchType
OBJECT-TYPE
The Cnu's switch chip type. It's useless for gataway type cnu.
1.3.6.1.4.1.25506.2.84.4.1.1.5INTEGER {rtl8306e(1), ar8236(2), mv6061(3), mv6031(4)}read-writecurrent
hh3cHPEOCCnuUniNum
OBJECT-TYPE
Uni number of the Cnu. It's useless for gataway type cnu.
1.3.6.1.4.1.25506.2.84.4.1.1.6Integer32read-writecurrent
hh3cHPEOCCnuPhy2Uni
OBJECT-TYPE
Reflection from phy port to uni port of the cnu. It's useless for gataway type cnu. For example, phy port 0,1,2,3 is reflect to uni port 1,2,3,4, then the value of this mib is {0,1,2,3}
1.3.6.1.4.1.25506.2.84.4.1.1.7OCTET STRINGread-writecurrent
hh3cHPEOCCnuAccessRowStatus
OBJECT-TYPE
Operation status.