HH3C-HPEOC-MIB
- Registered at
- 1.3.6.1.4.1.25506.2.84
- Last updated
- 2007-08-28 10:08
- Organization
- New H3C Tech. Co., Ltd.
- Namespace
- comware
- Source file
HH3C-HPEOC-MIB- Digest
sha256:05af4773c9d198f478c653d216238c4168ed504a3506e14adae642ee3b544024
Description
The objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification.
Contact
SMB EOC Team New H3C Technologies Co., Ltd. Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:310053.
Imports
| From | Symbols |
|---|---|
| HH3C-OID-MIB | hh3cCommon |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HH3C-HPEOC-MIB HH3C-OID-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hh3cHPEOCSystem OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.84.1 | |||
| hh3cHPEOCCltVlanType OBJECT-TYPE Control EOC CLT's VLAN type, ieee8021q : 802.1q VLAN mode, portbased : portbased VLAN mode. | 1.3.6.1.4.1.25506.2.84.1.1 | INTEGER {ieee8021q(1), portbased(2)} | read-write | current |
| hh3cHPEOCCltVlanManTable OBJECT-TYPE This table implements the management of CLT(Coax Line Terminal) VLAN. | 1.3.6.1.4.1.25506.2.84.1.2 | not-accessible | current | |
| hh3cHPEOCCltVlanManEntry OBJECT-TYPE The entry of the table hh3cHPEOCCltVlanManTable. | 1.3.6.1.4.1.25506.2.84.1.2.1 | not-accessible | current | |
| hh3cHPEOCCltEthPortType OBJECT-TYPE Control CLT ethernet ports' type, normal : port which used for normal translation, debug : port which used for debug. | 1.3.6.1.4.1.25506.2.84.1.2.1.1 | INTEGER {normal(1), debug(2)} | read-write | current |
| hh3cHPEOCCltSysManTable OBJECT-TYPE This table implements the management of CLT(Coax Line Terminal). | 1.3.6.1.4.1.25506.2.84.1.3 | not-accessible | current | |
| hh3cHPEOCCltSysManEntry OBJECT-TYPE The entry of the table hh3cHPEOCCltSysManTable. | 1.3.6.1.4.1.25506.2.84.1.3.1 | not-accessible | current | |
| hh3cHPEOCCltDescr OBJECT-TYPE Set the description of CLT. | 1.3.6.1.4.1.25506.2.84.1.3.1.1 | DisplayString (SIZE(0..126)) | read-write | current |
| hh3cHPEOCCltFwVersion OBJECT-TYPE EOC firmware version. If the object length is zero, it means the version is unknown. | 1.3.6.1.4.1.25506.2.84.1.3.1.2 | DisplayString | read-only | current |
| hh3cHPEOCCltLinkState OBJECT-TYPE The cable port's link state. The physicaldown(1) state indicates that the CLT is not powered on. The linkdown(2) state indicates that the CLT is powered on, but registers fail. The linkup(3) state indicates that the CLT is powered on, and registers successful. The loopback(4) state indecates that the CLT is powered on and registers successful, but loopback has detected. | 1.3.6.1.4.1.25506.2.84.1.3.1.3 | INTEGER {physicaldown(1), linkdown(2), linkup(3), loopback(4)} | read-only | current |
| hh3cHPEOCCnuSysManTable OBJECT-TYPE This table implements the management of CNUs. | 1.3.6.1.4.1.25506.2.84.1.4 | not-accessible | current | |
| hh3cHPEOCCnuSysManEntry OBJECT-TYPE The entry of the table hh3cHPEOCCnuSysManTable. | 1.3.6.1.4.1.25506.2.84.1.4.1 | not-accessible | current | |
| hh3cHPEOCCnuBcastControl OBJECT-TYPE Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable. | 1.3.6.1.4.1.25506.2.84.1.4.1.1 | TruthValue | read-write | current |
| hh3cHPEOCCnuAnonymStatus OBJECT-TYPE Anonymity status. true(1) - the user which uses the CNU is anonymous. false(2) - the user which uses the CNU has an account. | 1.3.6.1.4.1.25506.2.84.1.4.1.2 | TruthValue | read-only | current |
| hh3cHPEOCCnuMacLimit OBJECT-TYPE Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU. | 1.3.6.1.4.1.25506.2.84.1.4.1.3 | Unsigned32 | read-write | current |
| hh3cHPEOCCltAutoUpgrade OBJECT-TYPE Auto upgrade Status. true(1) - The firmware of the CNU will be auto changed by CLT. false(2)- The firmware of the CNU will not be auto changed. | 1.3.6.1.4.1.25506.2.84.1.5 | TruthValue | read-write | current |
| hh3cHPEOCOnLineCnuNumber OBJECT-TYPE The total number of the online CNU(s). | 1.3.6.1.4.1.25506.2.84.1.6 | Integer32 | read-only | current |
| hh3cHPEOCCpuMacAddress OBJECT-TYPE EOC CPU's MAC address. | 1.3.6.1.4.1.25506.2.84.1.7 | MacAddress | read-only | current |
| hh3cHPEOCOffLineCnuNumber OBJECT-TYPE The total number of the offline CNU(s). | 1.3.6.1.4.1.25506.2.84.1.8 | Integer32 | read-only | current |
| hh3cHPEOCDownLoadCNUFWResult OBJECT-TYPE Download CNU firmware result. | 1.3.6.1.4.1.25506.2.84.1.9 | DisplayString | accessible-for-notify | current |
| hh3cHPEOCCltAutoUpgradeType OBJECT-TYPE Type of auto upgrade status. It depends on hh3cHPEOCCltAutoUpgrade status. flash - The CLT auto upgrade the firmware inside its flash to the CNUs. ftp - First download the firmware from FTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs. tftp - First download the firmware from TFTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs. | 1.3.6.1.4.1.25506.2.84.1.10 | INTEGER {flash(1), ftp(2), tftp(3)} | read-write | current |
| hh3cHPEOCAutoUpObjects OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.84.1.11 | |||
| hh3cHPEOCServerAddress OBJECT-TYPE The address of remote host acting as server for operation. The default value is 0.0.0.0 | 1.3.6.1.4.1.25506.2.84.1.11.1 | IpAddress | read-write | current |
| hh3cHPEOCServerUser OBJECT-TYPE When using ftp to transfer files, the user name must be specified through this node. It contains 1 to 30 characters. | 1.3.6.1.4.1.25506.2.84.1.11.2 | DisplayString | read-write | current |
| hh3cHPEOCServerPassword OBJECT-TYPE Remote user password for copying via ftp protocol. Optionally, this object may be ignored for protocols other than ftp. It contains 1 to 31 characters. | 1.3.6.1.4.1.25506.2.84.1.11.3 | DisplayString | read-write | current |
| hh3cHPEOCCltLoopbackDetect OBJECT-TYPE Loopback detect Status. true(1) - The loopback detect is enabled. false(0)- The loopback detect is disabled. | 1.3.6.1.4.1.25506.2.84.1.12 | INTEGER {false(0), true(1)} | read-write | current |
| hh3cHPEOCTemplateEnable OBJECT-TYPE Use template for white-list cnu. true(1) - Use template is enabled. false(0)- Use template detect is disabled. | 1.3.6.1.4.1.25506.2.84.1.13 | INTEGER {false(0), true(1)} | read-write | current |
| hh3cHPEOCCableInfo OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.84.2 | |||
| hh3cHPEOCCableInfoTable OBJECT-TYPE This table defines the primary parameters of the cable information. | 1.3.6.1.4.1.25506.2.84.2.1 | not-accessible | current | |
| hh3cHPEOCCableInfoEntry OBJECT-TYPE The entry of the table hh3cHPEOCCableInfoTable. | 1.3.6.1.4.1.25506.2.84.2.1.1 | not-accessible | current | |
| hh3cHPEOCFECErrors OBJECT-TYPE The cable port's FEC bits errors ratio. FEC means the payload Forward Error Correction. It's a technology of controlling errors. Packets in transmission is checked by the receiver, if error occurs, the receiver will announce the sender to resend. | 1.3.6.1.4.1.25506.2.84.2.1.1.1 | Counter64 | read-only | current |
| hh3cHPEOCAvgBitsPerCarrier OBJECT-TYPE The cable port's average bits per carrier. | 1.3.6.1.4.1.25506.2.84.2.1.1.2 | Unsigned32 | read-only | current |
| hh3cHPEOCAvgSNRPerCarrier OBJECT-TYPE The cable port's signal noise ratio(SNR) bits per carrier. | 1.3.6.1.4.1.25506.2.84.2.1.1.3 | Integer32 | read-only | current |
| hh3cHPEOCAvgInPBCRCErrors OBJECT-TYPE The input PB CRC errors on average. | 1.3.6.1.4.1.25506.2.84.2.1.1.4 | Unsigned32 | read-only | current |
| hh3cHPEOCInTotalPkts OBJECT-TYPE The total number of packets(including bad packets) received on this interface. | 1.3.6.1.4.1.25506.2.84.2.1.1.5 | Counter64 | read-only | current |
| hh3cHPEOCAvgOutPower OBJECT-TYPE The cable port's power sent on average, the unit is db. | 1.3.6.1.4.1.25506.2.84.2.1.1.6 | Integer32 | read-only | current |
| hh3cHPEOCAvgOutPBCRCErrors OBJECT-TYPE The cable port's physical block(PB) cyclic redundancy check(CRC) errors sent on average. | 1.3.6.1.4.1.25506.2.84.2.1.1.7 | Unsigned32 | read-only | current |
| hh3cHPEOCOutTotalPkts OBJECT-TYPE The total count of the packets(including bad packets) sent on this interface. | 1.3.6.1.4.1.25506.2.84.2.1.1.8 | Counter64 | read-only | current |
| hh3cHPEOCBitPerSymbolTable OBJECT-TYPE This table defines the bits per symbol parameters of the cable line. | 1.3.6.1.4.1.25506.2.84.2.2 | not-accessible | current | |
| hh3cHPEOCBitPerSymbolEntry OBJECT-TYPE The entry of the table hh3cHPEOCBitPerSymbolTable. | 1.3.6.1.4.1.25506.2.84.2.2.1 | not-accessible | current | |
| hh3cHPEOCBitPerSymbolIndex OBJECT-TYPE The index of the hh3cHPEOCBitPerSymbolTable. | 1.3.6.1.4.1.25506.2.84.2.2.1.1 | Unsigned32 | not-accessible | current |
| hh3cHPEOCBitPerSymbol OBJECT-TYPE hh3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed frequency. Each 4 bits stand for one value, all the values picking-up will make up a cable bit map. | 1.3.6.1.4.1.25506.2.84.2.2.1.2 | OCTET STRING | read-only | current |
| hh3cHPEOCTemplate OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.84.3 | |||
| hh3cHPEOCTemplateGlobalTable OBJECT-TYPE This table defines the global parameters of the Template information. | 1.3.6.1.4.1.25506.2.84.3.1 | not-accessible | current | |
| hh3cHPEOCTemplateGlobalEntry OBJECT-TYPE The entry of the table hh3cHPEOCTemplateGlobalTable. | 1.3.6.1.4.1.25506.2.84.3.1.1 | not-accessible | current | |
| hh3cHPEOCTemplateIndex OBJECT-TYPE The index of cable Template. | 1.3.6.1.4.1.25506.2.84.3.1.1.1 | Integer32 | read-create | current |
| hh3cHPEOCTemplateType OBJECT-TYPE The cable Template's type, can not change after create it. | 1.3.6.1.4.1.25506.2.84.3.1.1.2 | INTEGER {switch(1), gateway(2)} | read-create | current |
| hh3cHPEOCTemplateName OBJECT-TYPE The cable Template's name, it's recommended to set it uniquely and understandably. Length: 1 to 15 characters. | 1.3.6.1.4.1.25506.2.84.3.1.1.3 | DisplayString | read-write | current |
| hh3cHPEOCTemplateDescr OBJECT-TYPE The cable Template's description. Length: 0 to 63 characters. | 1.3.6.1.4.1.25506.2.84.3.1.1.4 | DisplayString | read-write | current |
| hh3cHPEOCTemplateCnuMaxDownBW OBJECT-TYPE Maximum downstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64. | 1.3.6.1.4.1.25506.2.84.3.1.1.5 | Integer32 | read-write | current |
| hh3cHPEOCTemplateCnuMaxUpBW OBJECT-TYPE Maximum upstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64. | 1.3.6.1.4.1.25506.2.84.3.1.1.6 | Integer32 | read-write | current |
| hh3cHPEOCTemplateCnuBcastControl OBJECT-TYPE Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable. | 1.3.6.1.4.1.25506.2.84.3.1.1.7 | TruthValue | read-write | current |
| hh3cHPEOCTemplateCnuMacLimit OBJECT-TYPE Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU. | 1.3.6.1.4.1.25506.2.84.3.1.1.8 | Unsigned32 | read-write | current |
| hh3cHPEOCTemplateCb201VlanEn OBJECT-TYPE Use for Cb201 cnu only. true(1) - Enable vlan insert function. false(2) - Disable vlan insert function. | 1.3.6.1.4.1.25506.2.84.3.1.1.9 | TruthValue | read-write | current |
| hh3cHPEOCTemplateRowStatus OBJECT-TYPE Operation status. | 1.3.6.1.4.1.25506.2.84.3.1.1.10 | RowStatus | read-create | current |
| hh3cHPEOCTemplateSwitchTable OBJECT-TYPE This table defines the port parameters of the switch type cnu. it's not affect on the type of gateway Template. | 1.3.6.1.4.1.25506.2.84.3.2 | not-accessible | current | |
| hh3cHPEOCTemplateSwitchEntry OBJECT-TYPE The entry of the table hh3cHPEOCTemplateSwitchTable. | 1.3.6.1.4.1.25506.2.84.3.2.1 | not-accessible | current | |
| hh3cHPEOCTemplateUniIndex OBJECT-TYPE The index value which uniquely identifies the FE interface of the CNU. | 1.3.6.1.4.1.25506.2.84.3.2.1.1 | Integer32 | not-accessible | current |
| hh3cHPEOCTemplateUniSpeed OBJECT-TYPE User network interface speed. | 1.3.6.1.4.1.25506.2.84.3.2.1.2 | INTEGER {auto(1), s10M(10), s100M(100)} | read-write | current |
| hh3cHPEOCTemplateUniDuplex OBJECT-TYPE User network interface mode. | 1.3.6.1.4.1.25506.2.84.3.2.1.3 | INTEGER {full(1), half(2), auto(3)} | read-write | current |
| hh3cHPEOCTemplateUniPriority OBJECT-TYPE The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority. | 1.3.6.1.4.1.25506.2.84.3.2.1.4 | Integer32 (0..7) | read-write | current |
| hh3cHPEOCTemplateUniFlowControl OBJECT-TYPE Flow control status. true(1) - Flow control status enable. false(2) - Flow control status disable. | 1.3.6.1.4.1.25506.2.84.3.2.1.5 | TruthValue | read-write | current |
| hh3cHPEOCTemplateUniUpLineRate OBJECT-TYPE The max speed upload in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the upload speed is only restricted by the physical line. | 1.3.6.1.4.1.25506.2.84.3.2.1.6 | Unsigned32 | read-write | current |
| hh3cHPEOCTemplateUniDownLineRate OBJECT-TYPE The max speed download in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the download speed is only restricted by the physical line. | 1.3.6.1.4.1.25506.2.84.3.2.1.7 | Unsigned32 | read-write | current |
| hh3cHPEOCTemplateUniAdminStatus OBJECT-TYPE Control if open or close the UNI. If choose up(1), means the UNI is opened and packets can pass it. If choose down(2), means the UNI is closed and all packets will be discard. | 1.3.6.1.4.1.25506.2.84.3.2.1.8 | INTEGER {up(1), down(2)} | read-write | current |
| hh3cHPEOCTemplateUniVLANType OBJECT-TYPE port vlan types. hybrid (3) port can carry multiple VLANs. | 1.3.6.1.4.1.25506.2.84.3.2.1.9 | INTEGER {access(1), trunk(2), hybrid(3)} | read-write | current |
| hh3cHPEOCTemplateUniPvid OBJECT-TYPE The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on this port. | 1.3.6.1.4.1.25506.2.84.3.2.1.10 | Integer32 (1..4094) | read-write | current |
| hh3cHPEOCTemplateUniVlanTag OBJECT-TYPE VLAN is set tagged or untagged. | 1.3.6.1.4.1.25506.2.84.3.2.1.11 | INTEGER {tagged(1), untagged(2)} | read-write | current |
| hh3cHPEOCCnuAccess OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.84.4 | |||
| hh3cHPEOCCnuAccessTable OBJECT-TYPE This table defines the global parameters of the cnu type permitting to access. | 1.3.6.1.4.1.25506.2.84.4.1 | not-accessible | current | |
| hh3cHPEOCCnuAccessEntry OBJECT-TYPE The entry of the table hh3cHPEOCCnuAccessTable. | 1.3.6.1.4.1.25506.2.84.4.1.1 | not-accessible | current | |
| hh3cHPEOCCnuAccessIndex OBJECT-TYPE The index value which uniquely identifies the manuinfo of the CNU. | 1.3.6.1.4.1.25506.2.84.4.1.1.1 | Integer32 | read-create | current |
| hh3cHPEOCCnuHFID OBJECT-TYPE The Cnu's HFID. Every type Cnu has it's unique HFID. Length: 1 to 64 characters. | 1.3.6.1.4.1.25506.2.84.4.1.1.2 | DisplayString | read-write | current |
| hh3cHPEOCManuInfo OBJECT-TYPE The Cnu's manufactory infofamiont. Length: 0 to 63 characters. | 1.3.6.1.4.1.25506.2.84.4.1.1.3 | DisplayString | read-write | current |
| hh3cHPEOCCnuType OBJECT-TYPE The Cnu's function type. | 1.3.6.1.4.1.25506.2.84.4.1.1.4 | INTEGER {switch(1), gateway(2)} | read-write | current |
| hh3cHPEOCCnuSwitchType OBJECT-TYPE The Cnu's switch chip type. It's useless for gataway type cnu. | 1.3.6.1.4.1.25506.2.84.4.1.1.5 | INTEGER {rtl8306e(1), ar8236(2), mv6061(3), mv6031(4)} | read-write | current |
| hh3cHPEOCCnuUniNum OBJECT-TYPE Uni number of the Cnu. It's useless for gataway type cnu. | 1.3.6.1.4.1.25506.2.84.4.1.1.6 | Integer32 | read-write | current |
| hh3cHPEOCCnuPhy2Uni OBJECT-TYPE Reflection from phy port to uni port of the cnu. It's useless for gataway type cnu. For example, phy port 0,1,2,3 is reflect to uni port 1,2,3,4, then the value of this mib is {0,1,2,3} | 1.3.6.1.4.1.25506.2.84.4.1.1.7 | OCTET STRING | read-write | current |
| hh3cHPEOCCnuAccessRowStatus OBJECT-TYPE Operation status. | 1.3.6.1.4.1.25506.2.84.4.1.1.8 | RowStatus | read-create | current |