MIBs Depot

H3C-UPS-MIB

Registered at
1.3.6.1.4.1.2011.10.2.82
Last updated
2007-09-04 14:52
Organization
H3C Technologies Co., Ltd.
Namespace
huawei
Source file
H3C-UPS-MIB
Digest
sha256:4d50cbc151e40911e2e247efa7c1444f3f0f7e9f0e74b3a7f2fb57fc11474e01

Description

This MIB describes the general information of UPS(Uninterrupted Power Supply) device.

Contact

Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.h3c.com Zip:100085

Imports

FromSymbols
ENTITY-MIBentPhysicalIndex
HUAWEI-3COM-OID-MIBh3cCommon
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
H3C-UPS-MIB
HUAWEI-3COM-OID-MIB
IANA-ENTITY-MIB
INET-ADDRESS-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
H3cActionType
TEXTUAL-CONVENTION
A control variable used to trigger an operator events, when read, always returns a value of invalid.
current

Objects

NameOIDSyntaxAccessStatus
h3cUpsMibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.2.82.1
h3cUpsConfigEnable
OBJECT-TYPE
This object identifies the operation which will make the UPS(Uninterrupted Power Supply)'s new configure become effective.
1.3.6.1.4.1.2011.10.2.82.1.1H3cActionTyperead-writecurrent
h3cUpsConfigTable
OBJECT-TYPE
This table contains an entry for user to get some information about the UPS device.
1.3.6.1.4.1.2011.10.2.82.1.2not-accessiblecurrent
h3cUpsConfigEntry
OBJECT-TYPE
An entry containing management information applicable to a particular UPS.
1.3.6.1.4.1.2011.10.2.82.1.2.1not-accessiblecurrent
h3cUpsIndex
OBJECT-TYPE
This object identifies the index of h3cUpsConfigTable. The object identified by this index is the same object as identified by the same value of entPhysicalIndex.
1.3.6.1.4.1.2011.10.2.82.1.2.1.1Integer32not-accessiblecurrent
h3cUpsType
OBJECT-TYPE
This object identifies the type of UPS. The value 'emersonUart' means an EMERSON UPS support UART interface. The value 'mge' means a MGE UPS support ethernet interface. The value 'common' means a common UPS support standard UPSMIB. The value 'emersonEth' means an EMERSON UPS support ethernet interface. The value 'liebert' means a Liebert UPS support ethernet interface.
1.3.6.1.4.1.2011.10.2.82.1.2.1.2INTEGER {emersonUart(1), mge(2), common(3), emersonEth(4), liebert(5)}read-onlycurrent
h3cUpsIpAddress
OBJECT-TYPE
This object describes the address of UPS. The value of this object is invalid if the UPS do not support ethernet interface.
1.3.6.1.4.1.2011.10.2.82.1.2.1.3InetAddressread-writecurrent
h3cUpsIpAddressType
OBJECT-TYPE
This object describes the address type of UPS. The value of this object is invalid if the UPS do not support ethernet interface.
1.3.6.1.4.1.2011.10.2.82.1.2.1.4InetAddressTyperead-writecurrent