E5-110-AESCOMMON-MIB
- Registered at
- 1.3.6.1.4.1.6321.1.2.3.1.97.31.3.6.1.4.1.6321.1.2.3.1.97.41.3.6.1.4.1.6321.1.2.3.1.97.8
- Namespace
- calix
- Source file
E5-110-AESCOMMON-MIB- Digest
sha256:019977961fc180e9cd1a6c21e255e9290ca7a1f92a86aadba5887998c756266c
Imports
| From | Symbols |
|---|---|
| E5-110-MIB | aesSeriesCommon |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB E5-110-AESCOMMON-MIB E5-110-MIB IANAifType-MIB IF-MIB P-BRIDGE-MIB Q-BRIDGE-MIB RFC1158-MIB RFC1271-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC TOKEN-RING-RMON-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| aesMaxNumOfProfiles OBJECT-TYPE The maximum number of ADSL profiles which the system supports. | 1.3.6.1.4.1.6321.1.2.3.1.97.1 | INTEGER | read-only | current |
| aesLineConfTable OBJECT-TYPE This table includes common attributes describing the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2 | not-accessible | current | |
| aesLineConfEntry OBJECT-TYPE An entry in aesLineConfTable. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1 | not-accessible | current | |
| aesLineConfAdslMode OBJECT-TYPE The mode of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.1 | INTEGER {gDotLite(1), gDotDmt(2), t1Dot413(3), auto(4), etsi(5), adsl2(6), adsl2Plus(7)} | read-write | current |
| aesLineConfEncap OBJECT-TYPE The encapsulation of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.2 | INTEGER {llc(1), vc(2)} | read-write | current |
| aesLineConfVpi OBJECT-TYPE The VPI of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.3 | INTEGER | read-write | current |
| aesLineConfVci OBJECT-TYPE The VCI of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.4 | INTEGER | read-write | current |
| aesLineConfAnnexL OBJECT-TYPE The annex L setting of the ADSL line(Only in AnnexA). | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.5 | INTEGER {enableNarrowMode(1), enableWideMode(2), disable(3)} | read-write | current |
| aesLineConfPmMode OBJECT-TYPE The power management mode of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.6 | INTEGER {enableL2Mode(2), disable(3)} | read-write | current |
| aesLineConfRateMode OBJECT-TYPE Defines what form of transmit rate adaptation is configured on this modem. See ADSL Forum TR-005 [3] for more information. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.7 | INTEGER {fixed(1), adaptAtStartup(2), adaptAtRuntime(3)} | read-write | current |
| aesLineConfAnnexM OBJECT-TYPE The annex M setting of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.2.1.8 | INTEGER {enable(1), disable(2)} | read-write | current |
| aesLineDiagnostic OBJECT-IDENTITY | 1.3.6.1.4.1.6321.1.2.3.1.97.3 | |||
| aesAtucLineDiagLATN OBJECT-TYPE Line Attenuation. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.1 | INTEGER | read-only | current |
| aesAtucLineDiagSATN OBJECT-TYPE Signal Attenuation. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.2 | INTEGER | read-only | current |
| aesAtucLineDiagSNRM OBJECT-TYPE Signal-to-Noise Ratio Margin. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.3 | INTEGER | read-only | current |
| aesAtucLineDiagACTATP OBJECT-TYPE Actual Aggregate Transmit Power. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.4 | INTEGER | read-only | current |
| aesAtucLineDiagATTNDR OBJECT-TYPE Attainable Net Data Rate, in bps. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.5 | Unsigned32 | read-only | current |
| aesAturLineDiagLATN OBJECT-TYPE Line Attenuation. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.6 | INTEGER | read-only | current |
| aesAturLineDiagSATN OBJECT-TYPE Signal Attenuation. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.7 | INTEGER | read-only | current |
| aesAturLineDiagSNRM OBJECT-TYPE Signal-to-Noise Ratio Margin. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.8 | INTEGER | read-only | current |
| aesAturLineDiagACTATP OBJECT-TYPE Actual Aggregate Transmit Power. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.9 | INTEGER | read-only | current |
| aesAturLineDiagATTNDR OBJECT-TYPE Attainable Net Data Rate, in bps. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.10 | Unsigned32 | read-only | current |
| aesLineDiagTarget OBJECT-TYPE Ifindex of the ADSL port which will be diagnosed. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.11 | INTEGER | read-write | current |
| aesLineDiagOps OBJECT-TYPE The manager sets the object to one to start line diagnostics and the agent clears the object to zero when diagnostics is successfully completed. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.12 | INTEGER | read-write | current |
| aesLineDiagFailReason OBJECT-TYPE The reason of failed diagnostics. | 1.3.6.1.4.1.6321.1.2.3.1.97.3.13 | DisplayString | read-only | current |
| aesLineDiagPs OBJECT-IDENTITY | 1.3.6.1.4.1.6321.1.2.3.1.97.4 | |||
| aesAtucNumOfSubcarriersPerPort OBJECT-TYPE The number of subcarriers per port for ATU-C. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.1 | INTEGER | read-only | current |
| aesAturNumOfSubcarriersPerPort OBJECT-TYPE The number of subcarriers per port for ATU-R. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.2 | INTEGER | read-only | current |
| aesLineDiagPsCCFLirl1 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value is the real part of a complex value in liner scale. The first two octets specify the li.rl value for subcarrier 1, and the second two octets specify the li.rl value for subcarrier 2, and so on. The object provides li.rl values for subcarrier 1 to 256. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.3 | OCTET STRING | read-only | current |
| aesLineDiagPsCCFLirl2 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value is the real part of a complex value in liner scale. The first two octets specify the li.rl value for subcarrier 257, and the second two octets specify the li.rl value for subcarrier 258, and so on. The object provides li.rl values for subcarrier 257 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.4 | OCTET STRING | read-only | current |
| aesLineDiagPsCCFLiim1 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value is the image part of a complex value in liner scale. The first two octets specify the li.im value for subcarrier 1, and the second two octets specify the li.im value for subcarrier 2, and so on. The object provides li.im values for subcarrier 1 to 256. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.5 | OCTET STRING | read-only | current |
| aesLineDiagPsCCFLiim2 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value is the image part of a complex value in liner scale. The first two octets specify the li.im value for subcarrier 257, and the second two octets specify the li.im value for subcarrier 258, and so on. The object provides li.im values for subcarrier 257 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.6 | OCTET STRING | read-only | current |
| aesLineDiagPsCCFLog1 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value provides magnitude value in a logarithmic scale. The first two octets specify the log value for subcarrier 1, and the second two octets specify the log value for subcarrier 2, and so on. The object provides log values for subcarrier 1 to 256. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.7 | OCTET STRING | read-only | current |
| aesLineDiagPsCCFLog2 OBJECT-TYPE Channel Characteristics Function H(f) per subcarrier. The value provides magnitude value in a logarithmic scale. The first two octets specify the log value for subcarrier 257, and the second two octets specify the log value for subcarrier 258, and so on. The object provides log values for subcarrier 257 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.8 | OCTET STRING | read-only | current |
| aesLineDiagPsQLN OBJECT-TYPE Quiet Line Noise PSD QLN(f) per subcarrier. The first octet specify QLN for subcarrier 1, and the second octet specify QLN for subcarrier 2, and so on. The object provides QLN for subcarrier 1 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.9 | OCTET STRING | read-only | current |
| aesLineDiagPsSNR OBJECT-TYPE Signal-to-Noise Ratio SNR(f) per subcarrier. The first octet specify SNR for subcarrier 1, and the second octet specify SNR for subcarrier 2, and so on. The object provides SNR for subcarrier 1 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.4.10 | OCTET STRING | read-only | current |
| aesMaxNumOfAlarmProfiles OBJECT-TYPE The maximum number of ADSL alarm profiles which the system supports. | 1.3.6.1.4.1.6321.1.2.3.1.97.5 | INTEGER | read-only | current |
| aesBitLoadingTable OBJECT-TYPE This table provides the number of bits per carrier for each ADSL port. | 1.3.6.1.4.1.6321.1.2.3.1.97.6 | not-accessible | current | |
| aesBitLoadingEntry OBJECT-TYPE An entry in aesBitLoadingTable. | 1.3.6.1.4.1.6321.1.2.3.1.97.6.1 | not-accessible | current | |
| aesBitLoadingBits OBJECT-TYPE This object provides the number of bits for all carriers in the port. The first octet specify the number of bits for carrier 1, and the second octet specify the number of bits for carrier 2, and so on. The object provides the number of bits for carrier 1 to 512. | 1.3.6.1.4.1.6321.1.2.3.1.97.6.1.1 | OCTET STRING | read-only | current |
| aesBitLoadingAtucNumOfCarriers OBJECT-TYPE The number of carriers for ATU-C. | 1.3.6.1.4.1.6321.1.2.3.1.97.6.1.2 | INTEGER | read-only | current |
| aesBitLoadingAturNumOfCarriers OBJECT-TYPE The number of carriers for ATU-R. | 1.3.6.1.4.1.6321.1.2.3.1.97.6.1.3 | INTEGER | read-only | current |
| aesLineStatusTable OBJECT-TYPE This table includes the ADSL line status. | 1.3.6.1.4.1.6321.1.2.3.1.97.7 | not-accessible | current | |
| aesLineStatusEntry OBJECT-TYPE An entry in aesLineStatusTable. | 1.3.6.1.4.1.6321.1.2.3.1.97.7.1 | not-accessible | current | |
| aesLineStatusAdslMode OBJECT-TYPE The link up mode of the ADSL line. | 1.3.6.1.4.1.6321.1.2.3.1.97.7.1.1 | INTEGER {gDotLite(1), gDotDmt(2), t1Dot413(3), etsi(4), adsl2(5), adsl2Plus(6)} | read-only | current |
| selt OBJECT-IDENTITY | 1.3.6.1.4.1.6321.1.2.3.1.97.8 | |||
| seltTarget OBJECT-TYPE IfIndex of the port which would be performed single end loopback test. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.1 | INTEGER | read-write | current |
| seltOps OBJECT-TYPE The manager sets the object to 1 to start the selt and the agent clears the object to zero when selt is successfully completed. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.2 | INTEGER | read-write | current |
| seltStatus OBJECT-TYPE Status description of the selt result. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.3 | DisplayString | read-only | current |
| seltCableType OBJECT-TYPE The cable type that selt result indicates. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.4 | INTEGER {awg24(1), awg26(2)} | read-only | current |
| seltLoopEstimateLengthFt OBJECT-TYPE The estimated loop length that selt result indicates. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.5 | INTEGER | read-only | current |
| seltLoopEstimateLengthMeter OBJECT-TYPE The estimated loop length that selt result indicates. | 1.3.6.1.4.1.6321.1.2.3.1.97.8.6 | INTEGER | read-only | current |