MIBs Depot

CISCO-IETF-PW-MIB

Registered at
1.3.6.1.4.1.9.10.106
Last updated
2004-03-17 12:00
Organization
Cisco Systems, Inc.
Revisions
2004-03-17 12:00, 2003-02-26 12:00, 2002-05-26 12:00, 2002-01-30 12:00, 2001-11-07 12:00, 2001-07-11 12:00
Namespace
cisco
Source file
CISCO-IETF-PW-MIB
Digest
sha256:4ac746d752272b0244b51c8035998b7ef3f9d975b6567723abe172718cb99857

Description

This MIB contains managed object definitions for Pseudo Wire operation as in: Pate, P., et al, <draft-ietf-pwe3- framework>, Xiao, X., et al, <draft-ietf-pwe3- requirements>, Martini, L., et al, <draft-martini- l2circuit-trans-mpls>, and Martini, L., et al, <draft-martini-l2circuit-encap-mpls>. The indexes for this MIB are also used to index the PSN- specific tables and the VC-specific tables. The VC Type dictates which VC-specific MIB to use. For example, a 'cep' VC Type requires the use the configuration and status tables within the CEP-MIB. This MIB enable the use of any underlying packet switched network (PSN). Specific tables for the MPLS PSN is currently defined in a separate CISCO-IETF-PW-MPLS-MIB. Tables to support other PSNs (IP, L2TP for example) will be added to this MIB in future revisions. At the time of publication of this version, there are no PWE3 WG documents for all features and objects in this MIB, and the MIB is therefore subject to change based on the WG progress.

Contact

Thomas D. Nadeau Postal: Cisco Systems, Inc. 250 Apollo Drive Chelmsford, MA 01824 Tel: +1-978-497-3051 Email: tnadeau@cisco.com MPLS MIB Development Team Postal: Cisco Systems, Inc. 250 Apollo Drive Chelmsford, MA 01924 Tel: +1-978-497-3989 Email: ch-mpls-mib-dev@cisco.com

Imports

FromSymbols
CISCO-IETF-PW-TC-MIBCpwGroupID, CpwOperStatus, CpwVcIDType, CpwVcIndexType, CpwVcType
CISCO-SMIciscoExperiment
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, experimental, iso
SNMPv2-TCDisplayString, RowStatus, StorageType, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

4 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-IETF-PW-MIB
CISCO-IETF-PW-TC-MIB
CISCO-SMI
INET-ADDRESS-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
cpwVcObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.106.1
cpwVcIndexNext
OBJECT-TYPE
This object contains an appropriate value to be used for cpwVcIndex when creating entries in the cpwVcTable. The value 0 indicates that no unassigned entries are available. To obtain the value of cpwVcIndex for a new entry in the cpwVcTable, the manager issues a management protocol retrieval operation to obtain the current value of cpwVcIndex. After each retrieval operation, the agent should modify the value to reflect the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
1.3.6.1.4.1.9.10.106.1.1Unsigned32read-onlycurrent
cpwVcTable
OBJECT-TYPE
This table specifies information for connecting various emulated services to various tunnel type.
1.3.6.1.4.1.9.10.106.1.2not-accessiblecurrent
cpwVcEntry
OBJECT-TYPE
A row in this table represents an emulated virtual connection (VC) across a packet network. It is indexed by cpwVcIndex, which uniquely identifying a singular connection.
1.3.6.1.4.1.9.10.106.1.2.1not-accessiblecurrent
cpwVcIndex
OBJECT-TYPE
Index for the conceptual row identifying a VC within this PW Emulation VC table.
1.3.6.1.4.1.9.10.106.1.2.1.1CpwVcIndexTypenot-accessiblecurrent
cpwVcType
OBJECT-TYPE
This value indicate the service to be carried over this VC. Note: the exact set of VC types is yet to be worked out by the WG.
1.3.6.1.4.1.9.10.106.1.2.1.2CpwVcTyperead-createcurrent
cpwVcOwner
OBJECT-TYPE
Set by the operator to indicate the protocol responsible for establishing this VC. Value 'manual' is used in all cases where no maintenance protocol (PW signaling) is used to set-up the VC, i.e. require configuration of entries in the VC tables including VC labels, etc. The value 'maintenanceProtocol' is used in case of standard signaling of the VC for the specific PSN, for example LDP for MPLS PSN as specified in <draft- draft-martini- l2circuit-trans-mpls> or L2TP control protocol. Value 'other' is used for other types of signaling.
1.3.6.1.4.1.9.10.106.1.2.1.3INTEGER {manual(1), maintenanceProtocol(2), other(3)}read-createcurrent
cpwVcPsnType
OBJECT-TYPE
Set by the operator to indicate the PSN type on which this VC will be carried. Based on this object, the relevant PSN table entries are created in the in the PSN specific MIB modules. For example, if mpls(1) is defined, the agent create an entry in cpwVcMplsTable, which further define the MPLS PSN configuration. Note: the exact set of PSN types is yet to be worked out by the WG.
1.3.6.1.4.1.9.10.106.1.2.1.4INTEGER {mpls(1), l2tp(2), ip(3), mplsOverIp(4), gre(5), other(6)}read-createcurrent
cpwVcSetUpPriority
OBJECT-TYPE
This object define the relative set-up priority of the VC in a lowest-to-highest fashion, where 0 is the highest priority. VCs with the same priority are treated with equal priority. Dropped VC will be set 'dormant' (as indicated in cpwVcOperStatus). This value is significant if there are competing resources between VCs and the implementation support this feature. If not supported or not relevant, the value of zero MUST be used.
1.3.6.1.4.1.9.10.106.1.2.1.5Integer32 (0..7)read-createcurrent
cpwVcHoldingPriority
OBJECT-TYPE
This object define the relative holding priority of the VC in a lowest-to-highest fashion, where 0 is the highest priority. VCs with the same priority are treated with equal priority. Dropped VC will be set 'dormant' (as indicated in cpwVcOperStatus). This value is significant if there are competing resources between VCs and the implementation support this feature. If not supported or not relevant, the value of zero MUST be used.
1.3.6.1.4.1.9.10.106.1.2.1.6Integer32 (0..7)read-createcurrent
cpwVcInboundMode
OBJECT-TYPE
This object is used to enable greater security for implementation that use per platform VC label space. In strict mode, packets coming from the PSN are accepted only from tunnels that are associated to the same VC via the inbound tunnel table in the case of MPLS, or as identified by the source IP address in case of L2TP or IP PSN. The entries in the inbound tunnel table are either explicitly configured or implicitly known by the maintenance protocol used for VC set-up. If such association is not known, not configured or not desired, loose mode should be configured, and the node should accept the packet based on the VC label only regardless of the outer tunnel used to carry the VC.
1.3.6.1.4.1.9.10.106.1.2.1.7INTEGER {loose(1), strict(2)}read-createcurrent
cpwVcPeerAddrType
OBJECT-TYPE
Denotes the address type of the peer node maintenance protocol (signaling) address if PW maintenance protocol is used for the VC creation. It should be set to 'unknown' if PE/PW maintenance protocol is not used, i.e. cpwVcOwner is set to 'manual'.
1.3.6.1.4.1.9.10.106.1.2.1.8InetAddressTyperead-createcurrent
cpwVcPeerAddr
OBJECT-TYPE
This object contains the value of of the peer node address of the PW/PE maintenance protocol entity. This object should contain a value of 0 if not relevant (manual configuration of the VC).
1.3.6.1.4.1.9.10.106.1.2.1.9InetAddressread-createcurrent
cpwVcID
OBJECT-TYPE
Used in the outgoing VC ID field within the 'Virtual Circuit FEC Element' when LDP signaling is used or PW ID AVP for L2TP.
1.3.6.1.4.1.9.10.106.1.2.1.10CpwVcIDTyperead-createcurrent
cpwVcLocalGroupID
OBJECT-TYPE
Used in the Group ID field sent to the peer PWES within the maintenance protocol used for VC setup, zero if not used.
1.3.6.1.4.1.9.10.106.1.2.1.11CpwGroupIDread-createcurrent
cpwVcControlWord
OBJECT-TYPE
Define if the control word will be sent with each packet by the local node.
1.3.6.1.4.1.9.10.106.1.2.1.12TruthValueread-createcurrent
cpwVcLocalIfMtu
OBJECT-TYPE
If not equal zero, the optional IfMtu object in the maintenance protocol will be sent with this value, representing the locally supported MTU size over the interface (or the virtual interface) associated with the VC.
1.3.6.1.4.1.9.10.106.1.2.1.13Unsigned32 (0..65535)read-createcurrent
cpwVcLocalIfString
OBJECT-TYPE
Each VC is associated to an interface (or a virtual interface) in the ifTable of the node as part of the service configuration. This object defines if the maintenance protocol will send the interface's name as appears on the ifTable in the name object as part of the maintenance protocol. If set to false, the optional element will not be sent.
1.3.6.1.4.1.9.10.106.1.2.1.14TruthValueread-createcurrent
cpwVcRemoteGroupID
OBJECT-TYPE
Obtained from the Group ID field as received via the maintenance protocol used for VC setup, zero if not used. Value of 0xFFFF shall be used if the object is yet to be defined by the VC maintenance protocol.
1.3.6.1.4.1.9.10.106.1.2.1.15CpwGroupIDread-onlycurrent
cpwVcRemoteControlWord
OBJECT-TYPE
If maintenance protocol is used for VC establishment, this parameter indicates the received status of the control word usage, i.e. if packets will be received with control word or not. The value of 'notYetKnown' is used while the maintenance protocol has not yet received the indication from the remote node. In manual configuration of the VC this parameters indicate to the local node what is the expected encapsulation for the received packets.
1.3.6.1.4.1.9.10.106.1.2.1.16INTEGER {noControlWord(1), withControlWord(2), notYetKnown(3)}read-createcurrent
cpwVcRemoteIfMtu
OBJECT-TYPE
The remote interface MTU as (optionally) received from the remote node via the maintenance protocol. Should be zero if this parameter is not available or not used.
1.3.6.1.4.1.9.10.106.1.2.1.17Unsigned32read-onlycurrent
cpwVcRemoteIfString
OBJECT-TYPE
Indicate the interface description string as received by the maintenance protocol, MUST be NULL string if not applicable or not known yet.
1.3.6.1.4.1.9.10.106.1.2.1.18SnmpAdminString (SIZE(0..80))read-onlycurrent
cpwVcOutboundVcLabel
OBJECT-TYPE
The VC label used in the outbound direction (i.e. toward the PSN). It may be set up manually if owner is 'manual' or automatically otherwise. Examples: For MPLS PSN, it represents the 20 bits of VC tag, for L2TP it represent the 32 bits Session ID. If the label is not yet known (signaling in process), the object should return a value of 0xFFFF.
1.3.6.1.4.1.9.10.106.1.2.1.19Unsigned32read-createcurrent
cpwVcInboundVcLabel
OBJECT-TYPE
The VC label used in the inbound direction (i.e. packets received from the PSN. It may be set up manually if owner is 'manual' or automatically otherwise. Examples: For MPLS PSN, it represents the 20 bits of VC tag, for L2TP it represent the 32 bits Session ID. If the label is not yet known (signaling in process), the object should return a value of 0xFFFF.
1.3.6.1.4.1.9.10.106.1.2.1.20Unsigned32read-createcurrent
cpwVcName
OBJECT-TYPE
The canonical name assigned to the VC.
1.3.6.1.4.1.9.10.106.1.2.1.21SnmpAdminStringread-createcurrent
cpwVcDescr
OBJECT-TYPE
A textual string containing information about the VC. If there is no description this object contains a zero length string.
1.3.6.1.4.1.9.10.106.1.2.1.22SnmpAdminStringread-createcurrent
cpwVcCreateTime
OBJECT-TYPE
System time when this VC was created.
1.3.6.1.4.1.9.10.106.1.2.1.23TimeStampread-onlycurrent
cpwVcUpTime
OBJECT-TYPE
Number of consecutive ticks this VC has been 'up' in both directions together (i.e. 'up' is observed in cpwVcOperStatus.)
1.3.6.1.4.1.9.10.106.1.2.1.24TimeTicksread-onlycurrent
cpwVcAdminStatus
OBJECT-TYPE
The desired operational status of this VC.
1.3.6.1.4.1.9.10.106.1.2.1.25INTEGER {up(1), down(2), testing(3)}read-createcurrent
cpwVcOperStatus
OBJECT-TYPE
Indicates the actual combined operational status of this VC. It is 'up' if both cpwVcInboundOperStatus and cpwVcOutboundOperStatus are in 'up' state. For all other values, if the VCs in both directions are of the same value it reflects that value, otherwise it is set to the most severe status out of the two statuses. The order of severance from most severe to less severe is: unknown, notPresent, down, lowerLayerDown, dormant, testing, up. The operator may consult the per direction OperStatus for fault isolation per direction.
1.3.6.1.4.1.9.10.106.1.2.1.26CpwOperStatusread-onlycurrent
cpwVcInboundOperStatus
OBJECT-TYPE
Indicates the actual operational status of this VC in the inbound direction. - down: if PW signaling has not yet finished, or indications available at the service level indicate that the VC is not passing packets. - testing: if AdminStatus at the VC level is set to test. - dormant: The VC is not available because of the required resources are occupied VC with higher priority VCs . - notPresent: Some component is missing to accomplish the set up of the VC. - lowerLayerDown: The underlying PSN is not in OperStatus 'up'.
1.3.6.1.4.1.9.10.106.1.2.1.27CpwOperStatusread-onlycurrent
cpwVcOutboundOperStatus
OBJECT-TYPE
Indicates the actual operational status of this VC in the outbound direction - down: if PW signaling has not yet finished, or indications available at the service level indicate that the VC is not passing packets. - testing: if AdminStatus at the VC level is set to test. - dormant: The VC is not available because of the required resources are occupied VC with higher priority VCs . - notPresent: Some component is missing to accomplish the set up of the VC. - lowerLayerDown: The underlying PSN is not in OperStatus 'up'.
1.3.6.1.4.1.9.10.106.1.2.1.28CpwOperStatusread-onlycurrent
cpwVcTimeElapsed
OBJECT-TYPE
The number of seconds, including partial seconds, that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
1.3.6.1.4.1.9.10.106.1.2.1.29Integer32 (1..900)read-onlycurrent
cpwVcValidIntervals
OBJECT-TYPE
The number of previous 15-minute intervals for which data was collected. An agent with PW capability must be capable of supporting at least n intervals. The minimum value of n is 4, The default of n is 32 and the maximum value of n is 96. The value will be <n> unless the measurement was (re-) started within the last (<n>*15) minutes, in which case the value will be the number of complete 15 minute intervals for which the agent has at least some data. In certain cases (e.g., in the case where the agent is a proxy) it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available.
1.3.6.1.4.1.9.10.106.1.2.1.30Integer32 (0..96)read-onlycurrent
cpwVcRowStatus
OBJECT-TYPE
For creating, modifying, and deleting this row.
1.3.6.1.4.1.9.10.106.1.2.1.31RowStatusread-createcurrent
cpwVcStorageType
OBJECT-TYPE
This variable indicates the storage type for this object.
1.3.6.1.4.1.9.10.106.1.2.1.32StorageTyperead-createcurrent
cpwVcPerfCurrentTable
OBJECT-TYPE
This table provides per-VC performance information for the current interval.
1.3.6.1.4.1.9.10.106.1.3not-accessiblecurrent
cpwVcPerfCurrentEntry
OBJECT-TYPE
An entry in this table is created by the agent for every VC.
1.3.6.1.4.1.9.10.106.1.3.1not-accessiblecurrent
cpwVcPerfCurrentInHCPackets
OBJECT-TYPE
High capacity counter for number of packets received by the VC (from the PSN) in the current 15 minute interval.
1.3.6.1.4.1.9.10.106.1.3.1.1Counter64read-onlycurrent
cpwVcPerfCurrentInHCBytes
OBJECT-TYPE
High capacity counter for number of bytes received by the VC (from the PSN) in the current 15 minute interval.
1.3.6.1.4.1.9.10.106.1.3.1.2Counter64read-onlycurrent
cpwVcPerfCurrentOutHCPackets
OBJECT-TYPE
High capacity counter for number of packets forwarded by the VC (to the PSN) in the current 15 minute interval.
1.3.6.1.4.1.9.10.106.1.3.1.3Counter64read-onlycurrent
cpwVcPerfCurrentOutHCBytes
OBJECT-TYPE
High capacity counter for number of bytes forwarded by the VC (to the PSN) in the current 15 minute interval.
1.3.6.1.4.1.9.10.106.1.3.1.4Counter64read-onlycurrent
cpwVcPerfIntervalTable
OBJECT-TYPE
This table provides per-VC performance information for each interval.
1.3.6.1.4.1.9.10.106.1.4not-accessiblecurrent
cpwVcPerfIntervalEntry
OBJECT-TYPE
An entry in this table is created agent for every VC.
1.3.6.1.4.1.9.10.106.1.4.1not-accessiblecurrent
cpwVcPerfIntervalNumber
OBJECT-TYPE
A number N, between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. The minimum range of N is 1 through 4. The default range is 1 to 32. The maximum range of N is 1 through 96.
1.3.6.1.4.1.9.10.106.1.4.1.1Integer32 (1..96)not-accessiblecurrent
cpwVcPerfIntervalValidData
OBJECT-TYPE
This variable indicates if the data for this interval is valid.
1.3.6.1.4.1.9.10.106.1.4.1.2TruthValueread-onlycurrent
cpwVcPerfIntervalTimeElapsed
OBJECT-TYPE
The duration of a particular interval in seconds. Adjustments in the system's time-of-day clock, may cause the interval to be greater or less than the normal value. Therefore this actual interval value is provided.
1.3.6.1.4.1.9.10.106.1.4.1.3Integer32read-onlycurrent
cpwVcPerfIntervalInHCPackets
OBJECT-TYPE
High capacity counter for number of packets received by the VC (from the PSN) in a particular 15-minute interval.
1.3.6.1.4.1.9.10.106.1.4.1.4Counter64read-onlycurrent
cpwVcPerfIntervalInHCBytes
OBJECT-TYPE
High capacity counter for number of bytes received by the VC (from the PSN) in a particular 15-minute interval.
1.3.6.1.4.1.9.10.106.1.4.1.5Counter64read-onlycurrent
cpwVcPerfIntervalOutHCPackets
OBJECT-TYPE
High capacity counter for number of packets forwarded by the VC (to the PSN) in a particular 15-minute interval.
1.3.6.1.4.1.9.10.106.1.4.1.6Counter64read-onlycurrent
cpwVcPerfIntervalOutHCBytes
OBJECT-TYPE
High capacity counter for number of bytes forwarded by the VC (to the PSN) in a particular 15-minute interval.
1.3.6.1.4.1.9.10.106.1.4.1.7Counter64read-onlycurrent
cpwVcPerfTotalTable
OBJECT-TYPE
This table provides per-VC Performance information from VC start time.
1.3.6.1.4.1.9.10.106.1.5not-accessiblecurrent
cpwVcPerfTotalEntry
OBJECT-TYPE
An entry in this table is created agent for every VC.
1.3.6.1.4.1.9.10.106.1.5.1not-accessiblecurrent
cpwVcPerfTotalInHCPackets
OBJECT-TYPE
High capacity counter for number of packets received by the VC (from the PSN).
1.3.6.1.4.1.9.10.106.1.5.1.1Counter64read-onlycurrent
cpwVcPerfTotalInHCBytes
OBJECT-TYPE
High capacity counter for number of bytes received by the VC (from the PSN).
1.3.6.1.4.1.9.10.106.1.5.1.2Counter64read-onlycurrent
cpwVcPerfTotalOutHCPackets
OBJECT-TYPE
High capacity counter for number of packets forwarded by the VC (to the PSN).
1.3.6.1.4.1.9.10.106.1.5.1.3Counter64read-onlycurrent
cpwVcPerfTotalOutHCBytes
OBJECT-TYPE
High capacity counter for number of bytes forwarded by the VC (to the PSN).
1.3.6.1.4.1.9.10.106.1.5.1.4Counter64read-onlycurrent
cpwVcPerfTotalDiscontinuityTime
OBJECT-TYPE
The value of sysUpTime on the most recent occasion at which any one or more of this row Counter32 or Counter64 suffered a discontinuity. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value.
1.3.6.1.4.1.9.10.106.1.5.1.5TimeStampread-onlycurrent
cpwVcPerfTotalErrorPackets
OBJECT-TYPE
Counter for number of error at VC level processing, for example packets received with unknown VC label.
1.3.6.1.4.1.9.10.106.1.6Counter64read-onlycurrent
cpwVcIdMappingTable
OBJECT-TYPE
This table provides reverse mapping of the existing VCs based on vc type and VC ID ordering. This table is typically useful for EMS ordered query of existing VCs.
1.3.6.1.4.1.9.10.106.1.7not-accessiblecurrent
cpwVcIdMappingEntry
OBJECT-TYPE
An entry in this table is created by the agent for every VC configured by the cpwVcTable.
1.3.6.1.4.1.9.10.106.1.7.1not-accessiblecurrent
cpwVcIdMappingVcType
OBJECT-TYPE
The VC type (indicate the service) of this VC.
1.3.6.1.4.1.9.10.106.1.7.1.1CpwVcTypenot-accessiblecurrent
cpwVcIdMappingVcID
OBJECT-TYPE
The VC ID of this VC. Zero if the VC is configured manually.
1.3.6.1.4.1.9.10.106.1.7.1.2CpwVcIDTypenot-accessiblecurrent
cpwVcIdMappingPeerAddrType
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.4.1.9.10.106.1.7.1.3InetAddressTypenot-accessiblecurrent
cpwVcIdMappingPeerAddr
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.4.1.9.10.106.1.7.1.4InetAddressnot-accessiblecurrent
cpwVcIdMappingVcIndex
OBJECT-TYPE
The value that represent the VC in the cpwVcTable.
1.3.6.1.4.1.9.10.106.1.7.1.5CpwVcIndexTyperead-onlycurrent
cpwVcPeerMappingTable
OBJECT-TYPE
This table provides reverse mapping of the existing VCs based on vc type and VC ID ordering. This table is typically useful for EMS ordered query of existing VCs.
1.3.6.1.4.1.9.10.106.1.8not-accessiblecurrent
cpwVcPeerMappingEntry
OBJECT-TYPE
An entry in this table is created by the agent for every VC configured in cpwVcTable.
1.3.6.1.4.1.9.10.106.1.8.1not-accessiblecurrent
cpwVcPeerMappingPeerAddrType
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.4.1.9.10.106.1.8.1.1InetAddressTypenot-accessiblecurrent
cpwVcPeerMappingPeerAddr
OBJECT-TYPE
IP address type of the peer node.
1.3.6.1.4.1.9.10.106.1.8.1.2InetAddressnot-accessiblecurrent
cpwVcPeerMappingVcType
OBJECT-TYPE
The VC type (indicate the service) of this VC.
1.3.6.1.4.1.9.10.106.1.8.1.3CpwVcTypenot-accessiblecurrent
cpwVcPeerMappingVcID
OBJECT-TYPE
The VC ID of this VC. Zero if the VC is configured manually.
1.3.6.1.4.1.9.10.106.1.8.1.4CpwVcIDTypenot-accessiblecurrent
cpwVcPeerMappingVcIndex
OBJECT-TYPE
The value that represent the VC in the cpwVcTable.
1.3.6.1.4.1.9.10.106.1.8.1.5CpwVcIndexTyperead-onlycurrent
cpwVcUpDownNotifEnable
OBJECT-TYPE
If this object is set to true(1), then it enables the emission of cpwVcUp and cpwVcDown notifications; otherwise these notifications are not emitted.
1.3.6.1.4.1.9.10.106.1.9TruthValueread-writecurrent
cpwVcNotifRate
OBJECT-TYPE
This object defines the maximum number of PW VC notifications that can be emitted from the device per second.
1.3.6.1.4.1.9.10.106.1.10Unsigned32read-writecurrent
cpwVcNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.106.2
cpwVcConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.106.3
cpwVcGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.106.3.1
cpwVcCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.106.3.2

Notifications

NameOIDStatus
cpwVcDown
NOTIFICATION-TYPE
This notification is generated when the cpwVcOperStatus object for one or more contiguous entries in cpwVcTable are about to enter the down(2) state from some other state. The included values of cpwVcOperStatus MUST all be set equal to this down(2) state. The two instances of cpwVcOperStatus in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of cross-connects have transitioned into the down(2) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single cross-connect entry, then the instance identifier (and values) of the two cpwVcOperStatus objects MUST be identical.
1.3.6.1.4.1.9.10.106.2.1current
cpwVcUp
NOTIFICATION-TYPE
This notification is generated when the cpwVcOperStatus object for one or more contiguous entries in cpwVcTable are about to enter the up(1) state from some other state. The included values of cpwVcOperStatus MUST both be set equal to this new state (i.e: up(1)). The two instances of cpwVcOperStatus in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of cross-connects have transitioned into the up(1) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single cross-connect entry, then the instance identifier (and values) of the two cpwVcOperStatus objects MUST be the identical.
1.3.6.1.4.1.9.10.106.2.2current

Conformance

NameOIDStatus
cpwVcGroup
OBJECT-GROUP
Collection of objects needed for PW VC configuration.
1.3.6.1.4.1.9.10.106.3.1.1current
cpwVcPeformanceGroup
OBJECT-GROUP
Collection of objects needed for PW VC performance.
1.3.6.1.4.1.9.10.106.3.1.2current
cpwVcMappingTablesGroup
OBJECT-GROUP
Collection of objects contained in the reverse mapping tables.
1.3.6.1.4.1.9.10.106.3.1.3current
cpwVcNotificationsGroup
NOTIFICATION-GROUP
Set of notifications implemented in this module. None is mandatory.
1.3.6.1.4.1.9.10.106.3.1.4current
cpwModuleCompliance
MODULE-COMPLIANCE
The compliance statement for agent that support PW operation.
1.3.6.1.4.1.9.10.106.3.2.1current