- 2016-01-21 00:00, 2015-09-28 00:00, 2015-04-20 00:00, 2015-04-10 00:00, 2015-03-19 00:00, 2015-03-11 00:00, 2015-02-04 00:00, 2015-01-23 00:00, 2015-01-07 00:00, 2014-04-25 00:00, 2014-03-25 00:00, 2013-12-03 00:00, 2013-05-17 00:00, 2013-05-07 00:00, 2013-04-20 00:00, 2013-04-16 00:00, 2013-04-08 00:00, 2013-03-08 00:00, 2012-06-20 00:00
- Namespace
- ciena
- Source file
CIENA-CES-TIME-SYNC-MIB- Digest
sha256:1b810e3a2ac68be75abfb63aeac82570fe4dc358a8f90a4e4b4f91921f3f830a
Description
This MIB module defines objects and associated notifications for the System Timing feature.
Contact
Mib Meister 115 North Sullivan Road Spokane Valley, WA 99037 USA Phone: +1 509 242 9000 Email: support@ciena.com
Imports
| From | Symbols |
|---|---|
| CIENA-CES-MODULE-MIB | cienaCesModuleSlotName |
| CIENA-GLOBAL-MIB | cienaGlobalMacAddress, cienaGlobalSeverity |
| CIENA-SMI | cienaCesConfig, cienaCesNotifications |
| CIENA-TC | CienaGlobalState |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CIENA-CES-MODULE-MIB CIENA-CES-TIME-SYNC-MIB CIENA-GLOBAL-MIB CIENA-SMI CIENA-TC SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| SsmStratumLevel TEXTUAL-CONVENTION International and North American SSM Values | current | |||
| SyncBITSSignalEncoding TEXTUAL-CONVENTION Encoding method used on T1/E1 BITS signal. | current | |||
| SyncBITSSignalFormat TEXTUAL-CONVENTION Station Clock BITS signal format. Esf and sf are applied to t1 signal only where as ccs and cas are applied to e1 signal. | current | |||
| SyncBITSSignalMode TEXTUAL-CONVENTION Station Clock BITS signal mode. | current | |||
| SyncGPSFreqClock TEXTUAL-CONVENTION The frequency of the clock for a GPS input/output reference, set when the reference is configured with a clock mode of frequency. | current | |||
| SyncInterfaceProtocol TEXTUAL-CONVENTION Interface protocol of an input/output reference. | current | |||
| SyncPTPEncapType TEXTUAL-CONVENTION The PTP encapsulation type. | current | |||
| SyncPTPRatePps TEXTUAL-CONVENTION The PTP rate in pps. | current | |||
| SyncRefOperationalStatus TEXTUAL-CONVENTION Operational status of an input/output reference. | current | |||
| SyncTimingType TEXTUAL-CONVENTION The timing domain; frequency, phase or time of day. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| cienaCesTimeSyncMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1 | |||
| cienaCesTimeSyncObjects OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1 | |||
| cienaCesSyncAdminState OBJECT-TYPE Globally enable/disable Sync | 1.3.6.1.4.1.1271.2.1.28.1.1.1 | CienaGlobalState | read-only | current |
| cienaCesSyncOptionType OBJECT-TYPE Indication of which set of SSM values being used. Option 1 is for International standard and Option 2 is for North American. | 1.3.6.1.4.1.1271.2.1.28.1.1.2 | INTEGER {unknown(1), option1(2), option2(3)} | read-only | current |
| cienaCesSyncRevertiveMode OBJECT-TYPE Revertive mode. | 1.3.6.1.4.1.1271.2.1.28.1.1.3 | INTEGER {unknown(1), revertive(2), nonrevertive(3)} | read-only | current |
| cienaCesSyncWaitToRestoreTimer OBJECT-TYPE User configured timer for a timing reference source to wait before transitioning from bad to good clock signal. | 1.3.6.1.4.1.1271.2.1.28.1.1.4 | Unsigned32 | read-only | current |
| cienaCesSyncInputProtectionGroupTable OBJECT-TYPE A table of protection groups for input timing reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.5 | not-accessible | current | |
| cienaCesSyncInputProtectionGroupEntry OBJECT-TYPE An entry in this table represents information on a protection group for input timing reference | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1 | not-accessible | current | |
| cienaCesInputPGEntityId OBJECT-TYPE The unique identifier of this input protection group. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.1 | Integer32 (1) | not-accessible | current |
| cienaCesInputPGEntityName OBJECT-TYPE The unique name of this input protection group. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.2 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPGPreferredReference OBJECT-TYPE Preferred timing reference source, configured by users. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.3 | DisplayString (SIZE(1..31)) | read-only | deprecated |
| cienaCesInputPGSelectedReference OBJECT-TYPE System selected timing reference source. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPGForcedReference OBJECT-TYPE System was forced to used this timing reference source. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.5 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPGThresholdQualityLevel OBJECT-TYPE Specified Quality Level threshold for a reference source being selected. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.6 | SsmStratumLevel | read-only | current |
| cienaCesInputPGState OBJECT-TYPE Configured state of this protection group. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.7 | CienaGlobalState | read-only | deprecated |
| cienaCesInputPGStateDuration OBJECT-TYPE Duration since the system entered current state. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.8 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPGReferenceSwitchCount OBJECT-TYPE The number of timing reference switching since the system stared up. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.9 | Unsigned32 | read-only | current |
| cienaCesInputPGOperationalStatus OBJECT-TYPE Operational status of this protection group. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.10 | INTEGER {unknown(1), freerun(2), holdover(3), locked(4), acquiringlock(5), holdoverexpired(6)} | read-only | current |
| cienaCesInputPGTimingType OBJECT-TYPE The timing domain (freq/phase/tod) that this protection group belongs to. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.11 | SyncTimingType | read-only | current |
| cienaCesInputPGOperationalQualityLevel OBJECT-TYPE Operational Quality Level of the protection group. | 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.12 | SsmStratumLevel | read-only | current |
| cienaCesSyncInputProtectionUnitTable OBJECT-TYPE A table of protection units for input timing reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.6 | not-accessible | current | |
| cienaCesSyncInputProtectionUnitEntry OBJECT-TYPE An entry in this table represents information on a protection unit for input timing reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1 | not-accessible | current | |
| cienaCesInputPUEntityId OBJECT-TYPE The unique identifier of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1 | Integer32 (1..48) | not-accessible | current |
| cienaCesInputPUEntityName OBJECT-TYPE The unique name of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.2 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPUPGEntityName OBJECT-TYPE The identifier of the input protection group(s) which this input protection unit belongs to. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.3 | DisplayString | read-only | current |
| cienaCesInputPUTimingInterfaceName OBJECT-TYPE The interface name of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.4 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesInputPUTimingInterfaceProtocol OBJECT-TYPE The interface protocol of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.5 | SyncInterfaceProtocol | read-only | current |
| cienaCesInputPUUserPriority OBJECT-TYPE The user configured priority of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.6 | Unsigned32 | read-only | current |
| cienaCesInputPUOperationalQL OBJECT-TYPE Operational clock quality level of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.7 | SsmStratumLevel | read-only | current |
| cienaCesInputPUForcedQL OBJECT-TYPE User configured clock quality level that this input protection unit is forced to operate at. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.8 | SsmStratumLevel | read-only | current |
| cienaCesInputPUReceivedQL OBJECT-TYPE Actual received clock quality level of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.9 | SsmStratumLevel | read-only | current |
| cienaCesInputPUSsmEnabled OBJECT-TYPE Enable/disable reading of actual received clock quality level for this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.10 | INTEGER {unknown(1), disabled(2), enabled(3)} | read-only | current |
| cienaCesInputPUOperationalStatus OBJECT-TYPE Operational status of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.11 | SyncRefOperationalStatus | read-only | current |
| cienaCesInputPUBITSSignalMode OBJECT-TYPE BITS Signal Mode, set if BITS signal is used as a protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12 | SyncBITSSignalMode | read-only | current |
| cienaCesInputPUBITSSignalFormat OBJECT-TYPE BITS Signal Format, set if BITS signal is used as a protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.13 | SyncBITSSignalFormat | read-only | current |
| cienaCesInputPUBITSSignalEncoding OBJECT-TYPE BITS Signal encoding, set if BITS signal is used as a protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.14 | SyncBITSSignalEncoding | read-only | current |
| cienaCesInputPUUserOverridePriority OBJECT-TYPE The user configured override-priority of this input protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.15 | Unsigned32 | read-only | current |
| cienaCesInputPUPTPEncapType OBJECT-TYPE PTP Encapsulation Type, set if a PTP input is used as a protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.16 | SyncPTPEncapType | read-only | current |
| cienaCesInputPUGPSClockMode OBJECT-TYPE GPS clock mode, set if a GPS input is used as a protection unit. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.17 | SyncTimingType | read-only | current |
| cienaCesInputPUGPSFreqClock OBJECT-TYPE GPS frequency clock, set if a GPS input is used as a protection unit and the cienaCesInputPUGPSClockMode is set to frequency. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.18 | SyncGPSFreqClock | read-only | current |
| cienaCesInputPUBITSSignalSsmLocation OBJECT-TYPE BITS Signal Ssm Location, set if BITS signal is used as an input reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.19 | INTEGER {unknown(1), sa4(2), sa5(3), sa6(4), sa7(5), sa8(6)} | read-only | current |
| cienaCesSyncOutputTable OBJECT-TYPE A table of output timing references. | 1.3.6.1.4.1.1271.2.1.28.1.1.7 | not-accessible | current | |
| cienaCesSyncOutputEntry OBJECT-TYPE An entry in this table represents information for an output timing reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1 | not-accessible | current | |
| cienaCesOutputEntityId OBJECT-TYPE The unique identifier of this output reference entity. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.1 | Integer32 (1..48) | not-accessible | current |
| cienaCesOutputEntityName OBJECT-TYPE The unique name of this output reference entity. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.2 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesOutputTimingInterfaceName OBJECT-TYPE The interface name of this output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesOutputTimingInterfaceProtocol OBJECT-TYPE The interface protocol of this output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4 | SyncInterfaceProtocol | read-only | current |
| cienaCesOutputOperationalQL OBJECT-TYPE Operational clock quality level of this output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.5 | SsmStratumLevel | read-only | current |
| cienaCesOutputOperationalStatus OBJECT-TYPE Operational status of this output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.6 | SyncRefOperationalStatus | read-only | current |
| cienaCesOutputBITSSignalMode OBJECT-TYPE BITS Signal Mode, set if BITS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.7 | SyncBITSSignalMode | read-only | current |
| cienaCesOutputBITSSignalFormat OBJECT-TYPE BITS Signal Format, set if BITS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.8 | SyncBITSSignalFormat | read-only | current |
| cienaCesOutputBITSSignalEncoding OBJECT-TYPE BITS Signal encoding, set if BITS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.9 | SyncBITSSignalEncoding | read-only | current |
| cienaCesOutputBITSSignalLineBuildout OBJECT-TYPE BITS Signal Line Buildout, set if BITS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.10 | INTEGER {unknown(1), lbo133(2), lbo266(3), lbo399(4), lbo533(5), lbo655(6)} | read-only | current |
| cienaCesOutputBITSSignalSsmLocation OBJECT-TYPE BITS Signal Ssm Location, set if BITS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.11 | INTEGER {unknown(1), sa4(2), sa5(3), sa6(4), sa7(5), sa8(6)} | read-only | current |
| cienaCesOutputGPSClockMode OBJECT-TYPE GPS clock mode, set if a GPS signal is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.12 | SyncTimingType | read-only | current |
| cienaCesOutputGPSFreqClock OBJECT-TYPE GPS frequency clock, set if a GPS signal is used as an output reference and the cienaCesOutputGPSClockMode is set to frequency. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.13 | SyncGPSFreqClock | read-only | current |
| cienaCesOutputPTPEncapType OBJECT-TYPE PTP Encapsulation Type, set if a PTP output is used as an output reference. | 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.14 | SyncPTPEncapType | read-only | current |
| cienaCesSyncPTPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.8 | |||
| cienaCesSyncPTPGlobalConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1 | |||
| cienaCesSyncPTPAddrMode OBJECT-TYPE PTP Address Mode. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.1 | INTEGER {unknown(1), unicast(2), multicast(3)} | read-only | current |
| cienaCesSyncPTPTagPriority OBJECT-TYPE PTP tag priority | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.2 | Unsigned32 | read-only | current |
| cienaCesSyncPTPProtocolVersion OBJECT-TYPE PTP Protocol Version. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.3 | INTEGER {unknown(1), v2(2)} | read-only | current |
| cienaCesSyncPTPProfileVersion OBJECT-TYPE PTP Profile Version. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.4 | INTEGER {unknown(1), version1dot0(2)} | read-only | current |
| cienaCesSyncPTPProfileIdentifier OBJECT-TYPE PTP profile identifier address. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.5 | MacAddress | read-only | current |
| cienaCesSyncPTPDomainNumber OBJECT-TYPE PTP domain number. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.6 | Unsigned32 | read-only | current |
| cienaCesSyncPTPClockType OBJECT-TYPE PTP Clock Type. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.7 | INTEGER {unknown(1), ocslave(2), bc(3)} | read-only | current |
| cienaCesSyncPTPClockID OBJECT-TYPE PTP clock identifier. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.8 | DisplayString (SIZE(1..31)) | read-only | current |
| cienaCesSyncPTPDscp OBJECT-TYPE PTP DSCP. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.1.9 | Unsigned32 | read-only | current |
| cienaCesSyncPTPInputConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2 | |||
| cienaCesSyncPTPInputUnicastReqDuration OBJECT-TYPE PTP input unicast request duration in seconds. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.1 | Unsigned32 | read-only | current |
| cienaCesSyncPTPInputAnnounceRxLossNum OBJECT-TYPE PTP input announce Rx loss num (announce intervals). | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.2 | Unsigned32 | read-only | current |
| cienaCesSyncPTPInputAnnounceTxRateReq OBJECT-TYPE PTP input announce Tx rate request (pps). | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.3 | SyncPTPRatePps | read-only | current |
| cienaCesSyncPTPInputSyncTxRateReq OBJECT-TYPE PTP input sync Tx rate request (pps). | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.4 | SyncPTPRatePps | read-only | current |
| cienaCesSyncPTPInputDelayReqTxRate OBJECT-TYPE PTP input delay request Tx rate (pps). | 1.3.6.1.4.1.1271.2.1.28.1.1.8.2.5 | SyncPTPRatePps | read-only | current |
| cienaCesSyncPTPOutputConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.8.3 | |||
| cienaCesSyncPTPOutputMaxSlaveSessions OBJECT-TYPE Maximum number of allowed PTP slave sessions for PTP outputs. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.1 | Unsigned32 | read-only | current |
| cienaCesSyncPTPOutputTimestampMode OBJECT-TYPE PTP timestamp mode. | 1.3.6.1.4.1.1271.2.1.28.1.1.8.3.2 | INTEGER {unknown(1), onestep(2), twostep(3)} | read-only | current |
| cienaCesSyncGPSConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.9 | |||
| cienaCesSyncGPSOutputConfig OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.1.28.1.1.9.1 | |||
| cienaCesSyncGPSOutput1ppsPulseWidth OBJECT-TYPE The 1pps pulse width, in microseconds, for GPS output references (applicable to phase). | 1.3.6.1.4.1.1271.2.1.28.1.1.9.1.1 | Unsigned32 | read-only | current |
| cienaCesSyncHoldoverInterval OBJECT-TYPE User configured interval after which holdover quality level changes. | 1.3.6.1.4.1.1271.2.1.28.1.1.10 | INTEGER {unknown(1), indefinite(2), twentyfourhours(3)} | read-only | current |
| cienaCesSyncModuleSlotClockStatus OBJECT-TYPE Lock status of module slot. | 1.3.6.1.4.1.1271.2.1.28.1.1.11 | INTEGER {unknown(1), lossoflock(2), lockedtoprimaryctx(3), lockedtosecondaryctx(4)} | accessible-for-notify | current |
| cienaCesTimeSyncMIBNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.2.28 | |||
| cienaCesTimeSyncMIBNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.1271.2.2.28.0 |
Notifications
| Name | OID | Status |
|---|---|---|
| cienaCesSyncInputPUStateChangeNotification NOTIFICATION-TYPE Sent when a configured timing reference transitions states. | 1.3.6.1.4.1.1271.2.2.28.0.1 | current |
| cienaCesSyncInputProtectionGroupStateChangeNotification NOTIFICATION-TYPE Sent when a configured protection-group transitions states. | 1.3.6.1.4.1.1271.2.2.28.0.2 | current |
| cienaCesSyncModuleSlotClockStateChangeNotification NOTIFICATION-TYPE Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x. | 1.3.6.1.4.1.1271.2.2.28.0.3 | current |