MIBs Depot

BLADESPPALT-MIB

Registered at
1.3.6.1.4.1.2.6.158
Namespace
ibm
Source file
BLADESPPALT-MIB
Digest
sha256:99743260f0ae70cc5d5c68612f9db75df7f34ac16529f355f74babeeafa72c11

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BLADESPPALT-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.2.6.158.5immalertMIBIMMALERT-MIB

Objects

NameOIDSyntaxAccessStatus
ibm
OBJECT-IDENTITY
1.3.6.1.4.1.2
ibmProd
OBJECT-IDENTITY
1.3.6.1.4.1.2.6
supportProcessor
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158
mmRemoteSupTrapMIB
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158.3
remoteSupTrapMibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158.3.1
spTrapInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158.3.1.1
spTrapDateTime
OBJECT-TYPE
Timestamp of Local Date and Time when alert was generated NOTE: the format is changeable by a setting on the Management Module (Flex System only)
1.3.6.1.4.1.2.6.158.3.1.1.1DisplayStringread-onlymandatory
spTrapAppId
OBJECT-TYPE
Platform ID, either 'IBM Flex Chassis Management Module' (Flex System) or 'BladeCenter Management Module' (BladeCenter)
1.3.6.1.4.1.2.6.158.3.1.1.2DisplayStringread-onlymandatory
spTrapSpTxtId
OBJECT-TYPE
SP System Identification - Text Identification
1.3.6.1.4.1.2.6.158.3.1.1.3DisplayStringread-onlymandatory
spTrapSysUuid
OBJECT-TYPE
Host System UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.3.1.1.4DisplayStringread-onlymandatory
spTrapSysSern
OBJECT-TYPE
'Chassis Serial Number'(Flex System) or 'AMM Serial Number' (BladeCenter)
1.3.6.1.4.1.2.6.158.3.1.1.5DisplayStringread-onlymandatory
spTrapAppType
OBJECT-TYPE
Application Alert Type - Trap Type ID
1.3.6.1.4.1.2.6.158.3.1.1.6INTEGER (1..65535)read-onlymandatory
spTrapPriority
OBJECT-TYPE
Alert Severity Value - Critical Alert(0) - Major(1) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255)
1.3.6.1.4.1.2.6.158.3.1.1.7INTEGER (1..65535)read-onlymandatory
spTrapMsgText
OBJECT-TYPE
Alert Message Text
1.3.6.1.4.1.2.6.158.3.1.1.8DisplayStringread-onlymandatory
spTrapHostContact
OBJECT-TYPE
Host Contact
1.3.6.1.4.1.2.6.158.3.1.1.9DisplayStringread-onlymandatory
spTrapHostLocation
OBJECT-TYPE
Host Location
1.3.6.1.4.1.2.6.158.3.1.1.10DisplayStringread-onlymandatory
spTrapBladeName
OBJECT-TYPE
Server Name NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.11DisplayStringread-onlymandatory
spTrapBladeSern
OBJECT-TYPE
Server Serial Number NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.12DisplayStringread-onlymandatory
spTrapBladeUuid
OBJECT-TYPE
Server UUID(Universal Unique ID) NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.13DisplayStringread-onlymandatory
spTrapEvtName
OBJECT-TYPE
The event ID in decimal (hexidecimal format may be cross referenced in InfoCenter).
1.3.6.1.4.1.2.6.158.3.1.1.14Unsigned32 (1..4294967295)read-onlymandatory
spTrapSourceId
OBJECT-TYPE
The source identifier associated with the event that caused the trap - SERVPROC : event associated with the service processor - Audit : audit event (in audit log) - Stor_X : event associated with storage element X - IOMod_X : event associated with switch X - Cool_X : event associated with fan X - Power_X : event associated with power supply X - Blade_X : event associated with server X
1.3.6.1.4.1.2.6.158.3.1.1.15DisplayStringread-onlymandatory
spTrapCallHomeFlag
OBJECT-TYPE
The call home flag associated with the event that caused the trap - No Call Home generated with this event (0) - Call Home generated with this event if call home is enabled (1)
1.3.6.1.4.1.2.6.158.3.1.1.16Unsigned32 (1..4294967295)read-onlymandatory
spTrapSysIPAddress
OBJECT-TYPE
The chassis Management Module IP Address. NOTE: In some very rare cases, the IP address will indicate 0.0.0.0 instead of the proper configured IP address. This can happen on the initial trap that leaves the chassis Management Module if the associated event happens extremely early in the boot up cycle.
1.3.6.1.4.1.2.6.158.3.1.1.17DisplayStringread-onlymandatory
spTrapSysMachineModel
OBJECT-TYPE
Chassis Machine Type/Model
1.3.6.1.4.1.2.6.158.3.1.1.18DisplayStringread-onlymandatory
spTrapBladeMachineModel
OBJECT-TYPE
Server Machine Type/Model NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.19DisplayStringread-onlymandatory
spTrapBladeFRUSerialNumber
OBJECT-TYPE
Server Field Replaceable Unit (FRU) Serial Number NOTE: This will only be populated if a server event triggered this trap. spTrapBladeFRUSerialNumber is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.20DisplayStringread-onlymandatory
spTrapBladeEvtName
OBJECT-TYPE
The server event ID. This ID can be cross referenced in the InfoCenter. NOTE: This will only be populated if a server event triggered this trap. spTrapBladeEvtName is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.21DisplayStringread-onlymandatory
spBladeEventDataSource
OBJECT-TYPE
The 5 bytes are values from the IPMI standard SEL (System Event Log) entry received for from server. Byte 1 (SEL Byte 11) - IPMI Standard Sensor Type Byte 2 (SEL Byte 13) - IPMI Standard Event/Reading Type Code Byte 3 (SEL Byte 14) - Event Data 1 Byte 4 (SEL Byte 15) - Event Data 2 Byte 5 (SEL Byte 16) - Event Data 3 NOTE: This will only be populated if a server event triggered this trap. spBladeEventDataSource is only available on Flex System
1.3.6.1.4.1.2.6.158.3.1.1.22DisplayStringread-onlymandatory
spTrapAuxData
OBJECT-TYPE
Auxiliary data associated with the event. Truncated if more than 127 characters. NOTE: spTrapAuxData is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.23DisplayStringread-onlymandatory
spTrapComponentID
OBJECT-TYPE
Component ID to associate the trap with the location in the chassis and, if applicable, the node enclosure. NOTE: spTrapComponentID is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.24DisplayStringread-onlymandatory
spTrapComponentFRUInfo
OBJECT-TYPE
Field Replaceable Unit (FRU) of the component that caused the trap. NOTE: spTrapComponentFRUInfo is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.25DisplayStringread-onlymandatory
spTrapChassisName
OBJECT-TYPE
Chassis Name NOTE: This will only populate if the Chassis Name has been set. spTrapChassisName is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.26DisplayStringread-onlymandatory
spTrapSysRoomId
OBJECT-TYPE
Chassis Room ID NOTE: This will only populate if the Chassis Room ID has been set. spTrapSysRoomId is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.27DisplayStringread-onlymandatory
spTrapSysRackId
OBJECT-TYPE
Chassis Rack ID NOTE: This will only populate if the Chassis Rack ID has been set. spTrapSysRackId is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.28DisplayStringread-onlymandatory
spTrapSysRackU
OBJECT-TYPE
Chassis anchor (lowest) Rack U location NOTE: This will only populate if the Chassis lowest Rack U has been set (otherwise it will be '0'). spTrapSysRackU is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.29Unsigned32 (1..4294967295)read-onlymandatory
spTrapServiceableEventFlag
OBJECT-TYPE
The serviceable event flag associated with the event that caused the trap - the event requires no user action (0) - the event is serviceable and requires user attention (1) NOTE: spTrapServiceableEventFlag is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.30Unsigned32 (1..4294967295)read-onlymandatory
spLogSequenceNum
OBJECT-TYPE
Sequence number from the chassis event log or audit log. NOTE: Audit logs are stored separately internally. spLogSequenceNum is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.31Unsigned32 (1..4294967295)read-onlymandatory
spCimMsgID
OBJECT-TYPE
CIM Indication Message ID NOTE: spCimMsgID is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.32DisplayStringread-onlymandatory
spCimMsgPrefix
OBJECT-TYPE
CIM Indication Message ID name space, one of the following: - PLAT : DMTF platform registry - CMM : CMM message registry NOTE: spCimMsgPrefix is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.33DisplayStringread-onlymandatory
spEventCorrelator
OBJECT-TYPE
For events originated by the CMM: If this event is part of a event group, this will be the unique identifier from 1 - 255 for the event group. Zero means no group. An alert in the same event group replaces an active alert from the group. The recovery event in the group clears the active alert in the group. For events created by the node system-management processor that are logged by CMM: This field is a correlator from 0 - 254 that is the same for a node alert and the node recovery event for the alert. A node recovery event clears an existing node alert if all of the following fields from the node alert and the node recovery event match: the event correlator (spEventCorrelator) value, the Blade UUID (spTrapBladeUuid), and the Blade Event Data Source (spBladeEventDataSource). NOTE: spEventCorrelator is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.34Unsigned32 (0..4294967295)read-onlymandatory

Notifications

NameOIDStatus
mmTrapTempC
NOTIFICATION-TYPE
Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.0
mmTrapVoltC
NOTIFICATION-TYPE
Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.1
mmTrapTampC
NOTIFICATION-TYPE
Critical Alert: Physical intrusion of system has occurred. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.2
mmTrapMffC
NOTIFICATION-TYPE
Critical Alert: Multiple fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.3
mmTrapPsC
NOTIFICATION-TYPE
Critical Alert: Power supply failure.
1.3.6.1.4.1.2.6.158.3.0.4
mTrapHdC
NOTIFICATION-TYPE
Critical Alert: Hard disk drive failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.5
mmTrapVrmC
NOTIFICATION-TYPE
Critical Alert: Voltage Regulator Module(VRM) failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.6
mmTrapLogFullN
NOTIFICATION-TYPE
Non-Critical Alert: Event Log 100% Full.
1.3.6.1.4.1.2.6.158.3.0.7
mmTrapRdpsN
NOTIFICATION-TYPE
Non-Critical Alert: Redundant Power Supply failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.10
mmTrapSffC
NOTIFICATION-TYPE
Critical Alert: Single Fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.11
mmTrapTempN
NOTIFICATION-TYPE
Non-Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.12
mmTrapVoltN
NOTIFICATION-TYPE
Non-Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.13
mmTrapSecDvS
NOTIFICATION-TYPE
System Alert: Secondary Device warning. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.15
mmTrapPostToS
NOTIFICATION-TYPE
System Alert: Post Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.20
mmTrapOsToS
NOTIFICATION-TYPE
System Alert: OS Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.21
mmTrapAppS
NOTIFICATION-TYPE
System Alert: Application Alert.
1.3.6.1.4.1.2.6.158.3.0.22
mmTrapPoffS
NOTIFICATION-TYPE
System Alert: Power Off. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.23
mmTrapPonS
NOTIFICATION-TYPE
System Alert: Power On. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.24
mmTrapBootS
NOTIFICATION-TYPE
System Alert: System Boot Failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.25
mmTrapLdrToS
NOTIFICATION-TYPE
System Alert: OS Loader Timeout. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.26
mmTrapPFAS
NOTIFICATION-TYPE
System Alert: Predictive Failure Analysis(PFA) information. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.27
mmTrapRemoteLoginS
NOTIFICATION-TYPE
System Alert: Remote Login
1.3.6.1.4.1.2.6.158.3.0.30
mmTrapMsC
NOTIFICATION-TYPE
Critical Alert: Multiple switch module failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.31
mmTrapRmN
NOTIFICATION-TYPE
Non-Critical Alert: Redundant module. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.32
mmTrapKVMSwitchS
NOTIFICATION-TYPE
System Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.33
mmTrapSysInvS
NOTIFICATION-TYPE
System Alert: Inventory.
1.3.6.1.4.1.2.6.158.3.0.34
mmTrapSysLogS
NOTIFICATION-TYPE
System Alert: System Log 75% full.
1.3.6.1.4.1.2.6.158.3.0.35
mmTrapIhcC
NOTIFICATION-TYPE
Critical Alert: Incompatible hardware configuration. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.36
mmTrapNwChangeS
NOTIFICATION-TYPE
System Alert: Network change notification.
1.3.6.1.4.1.2.6.158.3.0.37
mmTrapBlThrS
NOTIFICATION-TYPE
System Alert: Blade Throttle. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.39
mmTrapPwrMgntS
NOTIFICATION-TYPE
System Alert: Power Management. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.0.40
mmTrapBladeC
NOTIFICATION-TYPE
Critical Alert: Blade.
1.3.6.1.4.1.2.6.158.3.0.128
mmTrapIOC
NOTIFICATION-TYPE
Critical Alert: I/O Module.
1.3.6.1.4.1.2.6.158.3.0.129
mmTrapChassisC
NOTIFICATION-TYPE
Critical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.0.130
mmTrapStorageC
NOTIFICATION-TYPE
Critical Alert: Storage Module.
1.3.6.1.4.1.2.6.158.3.0.131
mmTrapFanC
NOTIFICATION-TYPE
Critical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.0.133
mmTrapBladeN
NOTIFICATION-TYPE
Non-Critical Alert: Blade
1.3.6.1.4.1.2.6.158.3.0.160
mmTrapION
NOTIFICATION-TYPE
Non-Critical Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.0.161
mmTrapChassisN
NOTIFICATION-TYPE
Non-Critical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.0.162
mmTrapStorageN
NOTIFICATION-TYPE
Non-Critical Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.0.163
mmTrapPowerN
NOTIFICATION-TYPE
Non-Critical Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.0.164
mmTrapFanN
NOTIFICATION-TYPE
Non-Critical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.0.165
mmTrapBladeS
NOTIFICATION-TYPE
System Alert: Blade
1.3.6.1.4.1.2.6.158.3.0.176
mmTrapIOS
NOTIFICATION-TYPE
System Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.0.177
mmTrapChassisS
NOTIFICATION-TYPE
System Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.0.178
mmTrapStorageS
NOTIFICATION-TYPE
System Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.0.179
mmTrapPowerS
NOTIFICATION-TYPE
System Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.0.180
mmTrapFanS
NOTIFICATION-TYPE
System Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.0.181
mmTrapPwrDOS
NOTIFICATION-TYPE
System Alert: Power down or on.
1.3.6.1.4.1.2.6.158.3.0.182