MIBs Depot

IMMALERT-MIB

Registered at
1.3.6.1.4.1.2.6.158.5
Namespace
ibm
Source file
IMMALERT-MIB
Digest
sha256:8793d84b2fee107af9e729fae840b0979c4db08a7bc1d28e106cb2749816a65f

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, enterprises, iso, mib-2
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IMMALERT-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ibm
OBJECT-IDENTITY
1.3.6.1.4.1.2
ibmProd
OBJECT-IDENTITY
1.3.6.1.4.1.2.6
supportProcessor
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158
immalertMIB
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158.5
immtrapg
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.158.5.1
altDateTime
OBJECT-TYPE
Timestamp of Local Date and Time when alert was generated
1.3.6.1.4.1.2.6.158.5.1.1DisplayStringread-onlymandatory
altSpTxtId
OBJECT-TYPE
SP System Identification - Text Identification
1.3.6.1.4.1.2.6.158.5.1.3DisplayStringread-onlymandatory
altSysUuid
OBJECT-TYPE
Host System UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.5.1.5DisplayStringread-onlymandatory
altSysSern
OBJECT-TYPE
Host System Serial Number
1.3.6.1.4.1.2.6.158.5.1.6DisplayStringread-onlymandatory
altPriority
OBJECT-TYPE
Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)
1.3.6.1.4.1.2.6.158.5.1.8INTEGER (0..65535)read-onlymandatory
altMsgText
OBJECT-TYPE
Alert Message Text
1.3.6.1.4.1.2.6.158.5.1.9DisplayStringread-onlymandatory
altMsgID
OBJECT-TYPE
Alert Message ID
1.3.6.1.4.1.2.6.158.5.1.10INTEGERread-onlymandatory
altMsgIDPrefix
OBJECT-TYPE
Alert Message ID
1.3.6.1.4.1.2.6.158.5.1.11DisplayStringread-onlymandatory
altHostContact
OBJECT-TYPE
Host Contact
1.3.6.1.4.1.2.6.158.5.1.12DisplayStringread-onlymandatory
altHostLocation
OBJECT-TYPE
Host Location
1.3.6.1.4.1.2.6.158.5.1.13DisplayStringread-onlymandatory
altHostRoomID
OBJECT-TYPE
Host Location - Room ID
1.3.6.1.4.1.2.6.158.5.1.14DisplayStringread-onlymandatory
altHostRackID
OBJECT-TYPE
Host Location - Rack ID
1.3.6.1.4.1.2.6.158.5.1.15DisplayStringread-onlymandatory
altHostLowestUpos
OBJECT-TYPE
Host Location - Lowest U-position
1.3.6.1.4.1.2.6.158.5.1.16DisplayStringread-onlymandatory
altHostBladeBay
OBJECT-TYPE
Host Location - BladeBay
1.3.6.1.4.1.2.6.158.5.1.17DisplayStringread-onlymandatory
altEventID
OBJECT-TYPE
Event Identifier
1.3.6.1.4.1.2.6.158.5.1.18DisplayStringread-onlymandatory
altServiceable
OBJECT-TYPE
Serviceability information.
1.3.6.1.4.1.2.6.158.5.1.19INTEGER {notServiceable(0), serviceableByIBM(1), serviceableByCustomer(2)}read-onlymandatory
altTest
OBJECT-TYPE
This event generated for test purposes.
1.3.6.1.4.1.2.6.158.5.1.20INTEGER {false(0), true(1)}read-onlymandatory
altFailingFRUs
OBJECT-TYPE
Ordered list of Failing FRU Numbers, separated by commas.
1.3.6.1.4.1.2.6.158.5.1.21DisplayStringread-onlymandatory
altHostMTM
OBJECT-TYPE
Machine Type and Model for failing host.
1.3.6.1.4.1.2.6.158.5.1.22DisplayStringread-onlymandatory
altAuxData
OBJECT-TYPE
Auxiliary data that may be included for some events.
1.3.6.1.4.1.2.6.158.5.1.23DisplayStringread-onlymandatory

Notifications

NameOIDStatus
ibmSpTrapTempC
NOTIFICATION-TYPE
Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.6.158.5.0.0
ibmSpTrapVoltC
NOTIFICATION-TYPE
Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.6.158.5.0.1
ibmSpTrapPowerC
NOTIFICATION-TYPE
Critical Alert: Power failure.
1.3.6.1.4.1.2.6.158.5.0.4
ibmSpTrapHdC
NOTIFICATION-TYPE
Critical Alert: Hard disk drive failure.
1.3.6.1.4.1.2.6.158.5.0.5
ibmSpTrapRdpsC
NOTIFICATION-TYPE
Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.6.158.5.0.9
ibmSpTrapRdpsN
NOTIFICATION-TYPE
Non-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.6.158.5.0.10
ibmSpTrapFanC
NOTIFICATION-TYPE
Critical Alert: Single Fan failure.
1.3.6.1.4.1.2.6.158.5.0.11
ibmSpTrapTempN
NOTIFICATION-TYPE
Non-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.6.158.5.0.12
ibmSpTrapVoltN
NOTIFICATION-TYPE
Non-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.6.158.5.0.13
ibmSpTrapOsToS
NOTIFICATION-TYPE
System Alert: OS Timeout value exceeded.
1.3.6.1.4.1.2.6.158.5.0.21
ibmSpTrapAppS
NOTIFICATION-TYPE
System Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.0.22
ibmSpTrapPoffS
NOTIFICATION-TYPE
System Alert: Power Off.
1.3.6.1.4.1.2.6.158.5.0.23
ibmSpTrapPonS
NOTIFICATION-TYPE
System Alert: Power On.
1.3.6.1.4.1.2.6.158.5.0.24
ibmSpTrapBootS
NOTIFICATION-TYPE
System Alert: System Boot Failure.
1.3.6.1.4.1.2.6.158.5.0.25
ibmSpTrapLdrToS
NOTIFICATION-TYPE
System Alert: OS Loader Timeout.
1.3.6.1.4.1.2.6.158.5.0.26
ibmSpTrapPFAS
NOTIFICATION-TYPE
System Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.2.6.158.5.0.27
ibmSpTrapRLogin
NOTIFICATION-TYPE
Sev-Off Alert: Event Remote Login.
1.3.6.1.4.1.2.6.158.5.0.30
ibmSpTrapSysLogS
NOTIFICATION-TYPE
System Alert: System Log 75% full.
1.3.6.1.4.1.2.6.158.5.0.35
ibmSpTrapIhcC
NOTIFICATION-TYPE
Critical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.2.6.158.5.0.36
ibmSpTrapNwChangeS
NOTIFICATION-TYPE
System Alert: Network change notification.
1.3.6.1.4.1.2.6.158.5.0.37
ibmSpTrapCPUC
NOTIFICATION-TYPE
Critical Alert: CPU Error.
1.3.6.1.4.1.2.6.158.5.0.40
ibmSpTrapMemoryC
NOTIFICATION-TYPE
Critical Alert: Memory Error.
1.3.6.1.4.1.2.6.158.5.0.41
ibmSpTrapCPUN
NOTIFICATION-TYPE
Non-Critical Alert: CPU Error.
1.3.6.1.4.1.2.6.158.5.0.42
ibmSpTrapMemoryN
NOTIFICATION-TYPE
Non-Critical Alert: Memory Error.
1.3.6.1.4.1.2.6.158.5.0.43
ibmSpTrapHardwareC
NOTIFICATION-TYPE
Critical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.0.50
ibmSpTrapHardwareN
NOTIFICATION-TYPE
Non-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.0.60
ibmSpTrapPowerN
NOTIFICATION-TYPE
Non-Critical Alert: Power.
1.3.6.1.4.1.2.6.158.5.0.164
ibmSpTrapFanN
NOTIFICATION-TYPE
Non-Critical Alert: Fan Error.
1.3.6.1.4.1.2.6.158.5.0.165