IMMALERT-MIB
- Registered at
- 1.3.6.1.4.1.2.6.158.5
- Namespace
- ibm
- Source file
IMMALERT-MIB- Digest
sha256:8793d84b2fee107af9e729fae840b0979c4db08a7bc1d28e106cb2749816a65f
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, enterprises, iso, mib-2 |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IMMALERT-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ibm OBJECT-IDENTITY | 1.3.6.1.4.1.2 | |||
| ibmProd OBJECT-IDENTITY | 1.3.6.1.4.1.2.6 | |||
| supportProcessor OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.158 | |||
| immalertMIB OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.158.5 | |||
| immtrapg OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.158.5.1 | |||
| altDateTime OBJECT-TYPE Timestamp of Local Date and Time when alert was generated | 1.3.6.1.4.1.2.6.158.5.1.1 | DisplayString | read-only | mandatory |
| altSpTxtId OBJECT-TYPE SP System Identification - Text Identification | 1.3.6.1.4.1.2.6.158.5.1.3 | DisplayString | read-only | mandatory |
| altSysUuid OBJECT-TYPE Host System UUID(Universal Unique ID) | 1.3.6.1.4.1.2.6.158.5.1.5 | DisplayString | read-only | mandatory |
| altSysSern OBJECT-TYPE Host System Serial Number | 1.3.6.1.4.1.2.6.158.5.1.6 | DisplayString | read-only | mandatory |
| altPriority OBJECT-TYPE Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8) | 1.3.6.1.4.1.2.6.158.5.1.8 | INTEGER (0..65535) | read-only | mandatory |
| altMsgText OBJECT-TYPE Alert Message Text | 1.3.6.1.4.1.2.6.158.5.1.9 | DisplayString | read-only | mandatory |
| altMsgID OBJECT-TYPE Alert Message ID | 1.3.6.1.4.1.2.6.158.5.1.10 | INTEGER | read-only | mandatory |
| altMsgIDPrefix OBJECT-TYPE Alert Message ID | 1.3.6.1.4.1.2.6.158.5.1.11 | DisplayString | read-only | mandatory |
| altHostContact OBJECT-TYPE Host Contact | 1.3.6.1.4.1.2.6.158.5.1.12 | DisplayString | read-only | mandatory |
| altHostLocation OBJECT-TYPE Host Location | 1.3.6.1.4.1.2.6.158.5.1.13 | DisplayString | read-only | mandatory |
| altHostRoomID OBJECT-TYPE Host Location - Room ID | 1.3.6.1.4.1.2.6.158.5.1.14 | DisplayString | read-only | mandatory |
| altHostRackID OBJECT-TYPE Host Location - Rack ID | 1.3.6.1.4.1.2.6.158.5.1.15 | DisplayString | read-only | mandatory |
| altHostLowestUpos OBJECT-TYPE Host Location - Lowest U-position | 1.3.6.1.4.1.2.6.158.5.1.16 | DisplayString | read-only | mandatory |
| altHostBladeBay OBJECT-TYPE Host Location - BladeBay | 1.3.6.1.4.1.2.6.158.5.1.17 | DisplayString | read-only | mandatory |
| altEventID OBJECT-TYPE Event Identifier | 1.3.6.1.4.1.2.6.158.5.1.18 | DisplayString | read-only | mandatory |
| altServiceable OBJECT-TYPE Serviceability information. | 1.3.6.1.4.1.2.6.158.5.1.19 | INTEGER {notServiceable(0), serviceableByIBM(1), serviceableByCustomer(2)} | read-only | mandatory |
| altTest OBJECT-TYPE This event generated for test purposes. | 1.3.6.1.4.1.2.6.158.5.1.20 | INTEGER {false(0), true(1)} | read-only | mandatory |
| altFailingFRUs OBJECT-TYPE Ordered list of Failing FRU Numbers, separated by commas. | 1.3.6.1.4.1.2.6.158.5.1.21 | DisplayString | read-only | mandatory |
| altHostMTM OBJECT-TYPE Machine Type and Model for failing host. | 1.3.6.1.4.1.2.6.158.5.1.22 | DisplayString | read-only | mandatory |
| altAuxData OBJECT-TYPE Auxiliary data that may be included for some events. | 1.3.6.1.4.1.2.6.158.5.1.23 | DisplayString | read-only | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| ibmSpTrapTempC NOTIFICATION-TYPE Critical Alert: Temperature threshold exceeded. | 1.3.6.1.4.1.2.6.158.5.0.0 | |
| ibmSpTrapVoltC NOTIFICATION-TYPE Critical Alert: Voltage threshold exceeded. | 1.3.6.1.4.1.2.6.158.5.0.1 | |
| ibmSpTrapPowerC NOTIFICATION-TYPE Critical Alert: Power failure. | 1.3.6.1.4.1.2.6.158.5.0.4 | |
| ibmSpTrapHdC NOTIFICATION-TYPE Critical Alert: Hard disk drive failure. | 1.3.6.1.4.1.2.6.158.5.0.5 | |
| ibmSpTrapRdpsC NOTIFICATION-TYPE Critical Alert: Redundant Power Supply failure. | 1.3.6.1.4.1.2.6.158.5.0.9 | |
| ibmSpTrapRdpsN NOTIFICATION-TYPE Non-Critical Alert: Redundant Power Supply failure. | 1.3.6.1.4.1.2.6.158.5.0.10 | |
| ibmSpTrapFanC NOTIFICATION-TYPE Critical Alert: Single Fan failure. | 1.3.6.1.4.1.2.6.158.5.0.11 | |
| ibmSpTrapTempN NOTIFICATION-TYPE Non-Critical Alert: Temperature threshold exceeded. | 1.3.6.1.4.1.2.6.158.5.0.12 | |
| ibmSpTrapVoltN NOTIFICATION-TYPE Non-Critical Alert: Voltage threshold exceeded. | 1.3.6.1.4.1.2.6.158.5.0.13 | |
| ibmSpTrapOsToS NOTIFICATION-TYPE System Alert: OS Timeout value exceeded. | 1.3.6.1.4.1.2.6.158.5.0.21 | |
| ibmSpTrapAppS NOTIFICATION-TYPE System Alert: Application Alert. Refer to Message ID for specific condition. | 1.3.6.1.4.1.2.6.158.5.0.22 | |
| ibmSpTrapPoffS NOTIFICATION-TYPE System Alert: Power Off. | 1.3.6.1.4.1.2.6.158.5.0.23 | |
| ibmSpTrapPonS NOTIFICATION-TYPE System Alert: Power On. | 1.3.6.1.4.1.2.6.158.5.0.24 | |
| ibmSpTrapBootS NOTIFICATION-TYPE System Alert: System Boot Failure. | 1.3.6.1.4.1.2.6.158.5.0.25 | |
| ibmSpTrapLdrToS NOTIFICATION-TYPE System Alert: OS Loader Timeout. | 1.3.6.1.4.1.2.6.158.5.0.26 | |
| ibmSpTrapPFAS NOTIFICATION-TYPE System Alert: Predictive Failure Analysis(PFA) information. | 1.3.6.1.4.1.2.6.158.5.0.27 | |
| ibmSpTrapRLogin NOTIFICATION-TYPE Sev-Off Alert: Event Remote Login. | 1.3.6.1.4.1.2.6.158.5.0.30 | |
| ibmSpTrapSysLogS NOTIFICATION-TYPE System Alert: System Log 75% full. | 1.3.6.1.4.1.2.6.158.5.0.35 | |
| ibmSpTrapIhcC NOTIFICATION-TYPE Critical Alert: Incompatible hardware configuration. | 1.3.6.1.4.1.2.6.158.5.0.36 | |
| ibmSpTrapNwChangeS NOTIFICATION-TYPE System Alert: Network change notification. | 1.3.6.1.4.1.2.6.158.5.0.37 | |
| ibmSpTrapCPUC NOTIFICATION-TYPE Critical Alert: CPU Error. | 1.3.6.1.4.1.2.6.158.5.0.40 | |
| ibmSpTrapMemoryC NOTIFICATION-TYPE Critical Alert: Memory Error. | 1.3.6.1.4.1.2.6.158.5.0.41 | |
| ibmSpTrapCPUN NOTIFICATION-TYPE Non-Critical Alert: CPU Error. | 1.3.6.1.4.1.2.6.158.5.0.42 | |
| ibmSpTrapMemoryN NOTIFICATION-TYPE Non-Critical Alert: Memory Error. | 1.3.6.1.4.1.2.6.158.5.0.43 | |
| ibmSpTrapHardwareC NOTIFICATION-TYPE Critical Alert: Other Failure - refer to Message ID for specific condition. | 1.3.6.1.4.1.2.6.158.5.0.50 | |
| ibmSpTrapHardwareN NOTIFICATION-TYPE Non-Critical Alert: Warning - refer to Message ID for specific condition. | 1.3.6.1.4.1.2.6.158.5.0.60 | |
| ibmSpTrapPowerN NOTIFICATION-TYPE Non-Critical Alert: Power. | 1.3.6.1.4.1.2.6.158.5.0.164 | |
| ibmSpTrapFanN NOTIFICATION-TYPE Non-Critical Alert: Fan Error. | 1.3.6.1.4.1.2.6.158.5.0.165 |