ZhoneAPON-MIB

Registered at
1.3.6.1.4.1.5504.5.12.1
1.3.6.1.4.1.5504.5.12.3
Last updated
2006-04-25 14:45
Organization
Zhone Terchnologies, Inc.
Revisions
2006-04-25 11:03, 2005-04-18 14:42, 2004-06-09 11:56, 2004-03-25 16:27, 2003-12-08 15:29, 2003-11-19 12:49, 2003-08-18 15:59, 2003-08-12 11:25, 2003-08-05 10:12
Namespace
zhone
Source file
ZhoneAPON-MIB
Digest
sha256:0321b2c64374331a5c4fe827946178f8a885e9d1f5b1dd1a6fa8cc3ef91dfb66

Description

This is the Zhone ATM-PON mib.

Contact

Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
IF-MIBifAlias, ifCompliance, ifCompliance2, ifConnectorPresent, ifCounterDiscontinuityGroup, ifCounterDiscontinuityTime, ifFixedLengthGroup, ifGeneralGroup, ifGeneralInformationGroup, ifHCFixedLengthGroup, ifHCInBroadcastPkts, ifHCInMulticastPkts, ifHCInOctets, ifHCInUcastPkts, ifHCOutBroadcastPkts, ifHCOutMulticastPkts, ifHCOutOctets, ifHCOutUcastPkts, ifHCPacketGroup, ifHighSpeed, ifInBroadcastPkts, ifInMulticastPkts, ifIndex, ifLinkUpDownTrapEnable, ifName, ifNumber, ifOldObjectsGroup, ifOutBroadcastPkts, ifOutMulticastPkts, ifPacketGroup, ifPromiscuousMode, ifRcvAddressAddress, ifRcvAddressGroup, ifRcvAddressStatus, ifRcvAddressType, ifStackGroup, ifStackGroup2, ifStackHigherLayer, ifStackLastChange, ifStackLowerLayer, ifStackStatus, ifTableLastChange, ifTestCode, ifTestGroup, ifTestId, ifTestOwner, ifTestResult, ifTestStatus, ifTestType, ifVHCPacketGroup
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue
ZhoneapsMIB, sechtor100, sechtor300, sipCommonMIB, sipTC, sipUAMIB, zhoneAtm, zhoneBridge, zhoneCard, zhoneConsole, zhoneDrafts, zhoneDs3Ext, zhoneDsl, zhoneDsx, zhoneEnet, zhoneGenWtn, zhoneGroups, zhoneIma, zhoneInterfaceGroup, zhoneInterfaceTranslation, zhoneIp, zhoneLineTypes, zhoneMalc, zhoneMasterAgent, zhoneModules, zhoneOcx, zhonePhysical, zhonePls, zhonePpp, zhoneRadio, zhoneRegCpe, zhoneRegMalc, zhoneRegMux, zhoneRegPls, zhoneRegSechtor, zhoneRegWtn, zhoneShelf, zhoneShelfIndex, zhoneShelfSlotCompliance, zhoneShelfSlotGroup, zhoneSlotIndex, zhoneSonet, zhoneSubscriber, zhoneSystem, zhoneTrapModules, zhoneVoice, zhoneVoiceStats, zhoneVoip, zhoneWtn, zhoneZAP, zhoneZedge, zhoneZmsProduct, zhoneZplex
Zhone-TCZhoneAdminString, ZhoneRowStatus

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
Zhone
Zhone-TC
ZhoneAPON-MIB

Objects

NameOIDSyntaxAccessStatus
zhoneApon
OBJECT-IDENTITY
ATM Passive Optical Network-related Zhone MIBs.
1.3.6.1.4.1.5504.5.12current
zhoneOltConfigTable
OBJECT-TYPE
Optical Line Termination configuration table.
1.3.6.1.4.1.5504.5.12.1.2not-accessiblecurrent
zhoneOltConfigEntry
OBJECT-TYPE
An entry in the Olt Config table.
1.3.6.1.4.1.5504.5.12.1.2.1not-accessiblecurrent
zhoneOltConfigAutoLearn
OBJECT-TYPE
Auto-learn enable flag.
1.3.6.1.4.1.5504.5.12.1.2.1.1INTEGER {oltAutolearnEnable(1), oltAutolearnDisable(2)}read-writecurrent
zhoneOltConfigCellScrambling
OBJECT-TYPE
Cell scrambling option control flag.
1.3.6.1.4.1.5504.5.12.1.2.1.2INTEGER {oltCellScramblingOff(1), oltCellScramblingRxOnly(2), oltCellScramblingTxOnly(3), oltCellScramblingRxAndTx(4)}read-writecurrent
zhoneOltConfigBip8
OBJECT-TYPE
Bip8 - Bit Interleave Parity, a procedure whereby each bit of a resulting BIP8 parity byte is a parity bit done across a specific bit position.
1.3.6.1.4.1.5504.5.12.1.2.1.3INTEGER {oltBip8Off(1), oltBip8RxCorrectionOnly(2), oltBip8TxGenerationOnly(3), oltBip8RxAndTx(4)}read-writecurrent
zhoneOltConfigHec
OBJECT-TYPE
Headder Error Control field.
1.3.6.1.4.1.5504.5.12.1.2.1.4INTEGER {oltHecOff(1), oltHecRxCorrectionOnly(2), oltHecTxGenerationOnly(3), oltHecRxAndTx(4)}read-writecurrent
zhoneOltConfigHecRxBypass
OBJECT-TYPE
Cyclic Redundancy Check bypass for reception.
1.3.6.1.4.1.5504.5.12.1.2.1.5TruthValueread-writecurrent
zhoneOltConfigCrcRx
OBJECT-TYPE
Cyclic Redundancy Check for reception.
1.3.6.1.4.1.5504.5.12.1.2.1.6TruthValueread-writecurrent
zhoneOltConfigOverheadSize
OBJECT-TYPE
Overhead size definition field.
1.3.6.1.4.1.5504.5.12.1.2.1.7INTEGER {oltPonOverhead3Bytes(1), oltPonOverhead6Bytes(2), oltPonOverhead12Bytes(3)}read-writecurrent
zhoneOltConfigDelimiterPattern
OBJECT-TYPE
A unique pattern indicating the start of the ATM cell or minislot, which can be used to perform byte synchronization.
1.3.6.1.4.1.5504.5.12.1.2.1.8Integer32 (0..65535)read-writecurrent
zhoneOltConfigDelimiterSize
OBJECT-TYPE
Delimiter pattern size.
1.3.6.1.4.1.5504.5.12.1.2.1.9Integer32 (2..16)read-writecurrent
zhoneOltConfigCdrPattern
OBJECT-TYPE
Re-sync signal pattern.
1.3.6.1.4.1.5504.5.12.1.2.1.10Integer32 (0..65535)read-writecurrent
zhoneOltConfigCdrLocation
OBJECT-TYPE
Re-sync signal location.
1.3.6.1.4.1.5504.5.12.1.2.1.11Integer32 (0..32)read-writecurrent
zhoneOltConfigCdrActiveHigh
OBJECT-TYPE
Clock Data Recovery.
1.3.6.1.4.1.5504.5.12.1.2.1.12TruthValueread-writecurrent
zhoneOltConfigCpeLimit
OBJECT-TYPE
Cell phase error limit.
1.3.6.1.4.1.5504.5.12.1.2.1.13Integer32 (0..16)read-writecurrent
zhoneOltConfigLcdLimit
OBJECT-TYPE
Loss of cell delineation limit.
1.3.6.1.4.1.5504.5.12.1.2.1.14Integer32 (4..15)read-writecurrent
zhoneOltConfigLcdAlpha
OBJECT-TYPE
Number of cells in delineation error before the LCD alarm is raised.
1.3.6.1.4.1.5504.5.12.1.2.1.15Integer32 (1..15)read-writecurrent
zhoneOltConfigLcdDelta
OBJECT-TYPE
Number of cells received NOT in delineation error required to clear LCD Alarm.
1.3.6.1.4.1.5504.5.12.1.2.1.16Integer32 (1..15)read-writecurrent
zhoneOltConfigTxDiscardNonMatchingVpi
OBJECT-TYPE
Discard non-matching Vpi.
1.3.6.1.4.1.5504.5.12.1.2.1.17TruthValueread-writecurrent
zhoneOltConfigUtopiaDiscard
OBJECT-TYPE
Discard Utopia cells with HEC errors or arriving on unknown Vpi.
1.3.6.1.4.1.5504.5.12.1.2.1.18TruthValueread-writecurrent
zhoneOltConfigSyncBytesClkDivisor
OBJECT-TYPE
Sync Bytes Clock Divisor.
1.3.6.1.4.1.5504.5.12.1.2.1.19Integer32 (0..65535)read-writecurrent
zhoneOltConfigTxSyncBytes
OBJECT-TYPE
Enable transmission of sync bytes for ONUs to get their clock from a network source.
1.3.6.1.4.1.5504.5.12.1.2.1.20INTEGER {txSyncBytesEnable(1), txSyncBytesDisable(2)}read-writecurrent
zhoneOltConfigLoopback
OBJECT-TYPE
OLT loopback configuration.
1.3.6.1.4.1.5504.5.12.1.2.1.21INTEGER {loopbackNone(1), loopbackInward(2), loopbackLine(3)}read-writecurrent
zhoneOltConfigMaxPonDistance
OBJECT-TYPE
Max PON distance.
1.3.6.1.4.1.5504.5.12.1.2.1.22Integer32 (0..255)read-writecurrent
zhoneOltConfigLineStatusChangeTrapEnable
OBJECT-TYPE
Enable/disable control for line status traps on this interface.
1.3.6.1.4.1.5504.5.12.1.2.1.23INTEGER {enabled(1), disabled(2)}read-writecurrent
zhoneOltStatusTable
OBJECT-TYPE
Optical Line Termination status table.
1.3.6.1.4.1.5504.5.12.1.3not-accessiblecurrent
zhoneOltStatusEntry
OBJECT-TYPE
An entry in the OLT Status table.
1.3.6.1.4.1.5504.5.12.1.3.1not-accessiblecurrent
zhoneOltStatusState
OBJECT-TYPE
Line state of the OLT.
1.3.6.1.4.1.5504.5.12.1.3.1.1INTEGER {oltStateDown(1), oltStateUp(2)}read-onlycurrent
zhoneOltStatusLoopback
OBJECT-TYPE
Loopback state of the OLT.
1.3.6.1.4.1.5504.5.12.1.3.1.2INTEGER {oltLoopbackNone(1), oltLoopbackInward(2), oltLoopbackLine(3)}read-onlycurrent
zhoneOltStatusPonAlarmLPHY
OBJECT-TYPE
Loss of physical layer alarm.
1.3.6.1.4.1.5504.5.12.1.3.1.3TruthValueread-onlycurrent
zhoneOltStatusPonAlarmTF
OBJECT-TYPE
Transmitter failure notification.
1.3.6.1.4.1.5504.5.12.1.3.1.4TruthValueread-onlycurrent
zhoneOltStatusPonAlarmSUF
OBJECT-TYPE
StartUp Failure - ranging process failed N times. Note that SUF reflects a hardware problem, and does not include cases where the ONU serial number/password are wrong/unknown.
1.3.6.1.4.1.5504.5.12.1.3.1.5TruthValueread-onlycurrent
zhoneOltStatusPonAlarmPEE
OBJECT-TYPE
Physical Equipment Error (received from an ONU.)
1.3.6.1.4.1.5504.5.12.1.3.1.6TruthValueread-onlycurrent
zhoneOltStatusPonAlarmLCD
OBJECT-TYPE
Loss of Cell Delineation.
1.3.6.1.4.1.5504.5.12.1.3.1.7TruthValueread-onlycurrent
zhoneOltStatusPonAlarmLOS
OBJECT-TYPE
Loss of Signal alarm.
1.3.6.1.4.1.5504.5.12.1.3.1.8TruthValueread-onlycurrent
zhoneOltStatusPonAlarmOAML
OBJECT-TYPE
PLOAM cell loss.
1.3.6.1.4.1.5504.5.12.1.3.1.9TruthValueread-onlycurrent
zhoneOltStatusPonAlarmCPE
OBJECT-TYPE
Cell Phase Error.
1.3.6.1.4.1.5504.5.12.1.3.1.10TruthValueread-onlycurrent
zhoneOltStatusLastChange
OBJECT-TYPE
Time of last line status change.
1.3.6.1.4.1.5504.5.12.1.3.1.11TimeStampread-onlycurrent
zhoneOltOnuConfigTable
OBJECT-TYPE
Optical Network Unit configuration table - MALC side.
1.3.6.1.4.1.5504.5.12.1.4not-accessiblecurrent
zhoneOltOnuConfigEntry
OBJECT-TYPE
An entry in the ONU Config table.
1.3.6.1.4.1.5504.5.12.1.4.1not-accessiblecurrent
zhoneOltOnuConfigPassword
OBJECT-TYPE
ONU remote-device password.
1.3.6.1.4.1.5504.5.12.1.4.1.1ZhoneAdminString (SIZE(0..10))read-writecurrent
zhoneOltOnuConfigSerialNum
OBJECT-TYPE
ONU remote-device serial number.
1.3.6.1.4.1.5504.5.12.1.4.1.2Integer32 (1..2147483647)read-writecurrent
zhoneOltOnuConfigChurnkey
OBJECT-TYPE
Churn key enable flag.
1.3.6.1.4.1.5504.5.12.1.4.1.3INTEGER {onuChurnkeyEnable(1), onuChurnkeyDisable(2)}read-writecurrent
zhoneOltOnuConfigLineStatusChangeTrapEnable
OBJECT-TYPE
Enable/disable control for line status traps on this interface.
1.3.6.1.4.1.5504.5.12.1.4.1.4INTEGER {enabled(1), disabled(2)}read-writecurrent
zhoneOltOnuStatusTable
OBJECT-TYPE
Optical Network Unit status table - MALC side.
1.3.6.1.4.1.5504.5.12.1.5not-accessiblecurrent
zhoneOltOnuStatusEntry
OBJECT-TYPE
An entry in the OLT/ONU Status table.
1.3.6.1.4.1.5504.5.12.1.5.1not-accessiblecurrent
zhoneOltOnuStatusPonAlarmLOA
OBJECT-TYPE
Loss of ACK - ONU.
1.3.6.1.4.1.5504.5.12.1.5.1.1TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmERR
OBJECT-TYPE
Bip8 error - ONU.
1.3.6.1.4.1.5504.5.12.1.5.1.2TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmSD
OBJECT-TYPE
Signal Degraded alarm.
1.3.6.1.4.1.5504.5.12.1.5.1.3TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmREI
OBJECT-TYPE
Remote Error Indication.
1.3.6.1.4.1.5504.5.12.1.5.1.4TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmMEM
OBJECT-TYPE
Message Error Message.
1.3.6.1.4.1.5504.5.12.1.5.1.5TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmRXINH
OBJECT-TYPE
Rx alarm inhibit.
1.3.6.1.4.1.5504.5.12.1.5.1.6TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmLOS
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.5.1.7TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmPEE
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.5.1.8TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmSUF
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.5.1.9TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmOAML
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.5.1.10TruthValueread-onlycurrent
zhoneOltOnuStatusPonAlarmLCD
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.5.1.11TruthValueread-onlycurrent
zhoneOnuConfigTable
OBJECT-TYPE
Configuration information for the far-end (ONU) device.
1.3.6.1.4.1.5504.5.12.1.6not-accessiblecurrent
zhoneOnuConfigEntry
OBJECT-TYPE
An entry in the ONU Config table.
1.3.6.1.4.1.5504.5.12.1.6.1not-accessiblecurrent
zhoneOnuConfigSerialNumber
OBJECT-TYPE
ONU serial number.
1.3.6.1.4.1.5504.5.12.1.6.1.1Integer32 (1..2147483647)read-onlycurrent
zhoneOnuConfigPassword
OBJECT-TYPE
ONU password.
1.3.6.1.4.1.5504.5.12.1.6.1.2ZhoneAdminStringread-writecurrent
zhoneOnuConfigNetworkRefClk
OBJECT-TYPE
Network reference clock usage flag.
1.3.6.1.4.1.5504.5.12.1.6.1.3TruthValueread-writecurrent
zhoneOnuConfigHEC
OBJECT-TYPE
Header Error Control.
1.3.6.1.4.1.5504.5.12.1.6.1.4INTEGER {onuOff(1), onuRxCorrectionOnly(2), onuTxGenerationOnly(3), onuRxAndTx(4)}read-writecurrent
zhoneOnuConfigLoopback
OBJECT-TYPE
Loopback mode for device.
1.3.6.1.4.1.5504.5.12.1.6.1.5INTEGER {onuNone(1), onuInward(2), onuLine(3)}read-writecurrent
zhoneOnuConfigOverheadSize
OBJECT-TYPE
Overhead size definition field.
1.3.6.1.4.1.5504.5.12.1.6.1.6INTEGER {onuOverheadSize3Bytes(1), onuOverheadSize6Bytes(2), onuOverheadSize12Bytes(3)}read-writecurrent
zhoneOnuConfigRfVideo
OBJECT-TYPE
Used to turn rf video on and off and to read current status of rf video.
1.3.6.1.4.1.5504.5.12.1.6.1.7INTEGER {enabled(1), disabled(2)}read-writecurrent
zhoneOnuStatusTable
OBJECT-TYPE
Status and alarm information for the far-end (ONU) device.
1.3.6.1.4.1.5504.5.12.1.7not-accessiblecurrent
zhoneOnuStatusEntry
OBJECT-TYPE
An entry in the ONU Status table.
1.3.6.1.4.1.5504.5.12.1.7.1not-accessiblecurrent
zhoneOnuStatusOperStatus
OBJECT-TYPE
Operational status.
1.3.6.1.4.1.5504.5.12.1.7.1.1INTEGER {onuStateDown(1), onuStateUp(2)}read-onlycurrent
zhoneOnuStatusLoopback
OBJECT-TYPE
Loopback status.
1.3.6.1.4.1.5504.5.12.1.7.1.2INTEGER {onuNone(1), onuInward(2), onuLine(3)}read-onlycurrent
zhoneOnuStatusAlarmTF
OBJECT-TYPE
Transmitter Failure - The ONU transmitter is declared in failure when there is no nominal backfacet photocurrent or when the drive currents go beyond the maximum specification.
1.3.6.1.4.1.5504.5.12.1.7.1.3TruthValueread-onlycurrent
zhoneOnuStatusAlarmLOS
OBJECT-TYPE
Loss Of Signal - No valid optical signal. E.g. this can be generated by the logical function (OAML.AND.FRML.AND.LCD).
1.3.6.1.4.1.5504.5.12.1.7.1.4TruthValueread-onlycurrent
zhoneOnuStatusAlarmPEE
OBJECT-TYPE
Physical Equipment Error - When the ONU receives a PEE message.
1.3.6.1.4.1.5504.5.12.1.7.1.5TruthValueread-onlycurrent
zhoneOnuStatusAlarmSUF
OBJECT-TYPE
Startup Failure - The ranging of this ONU has failed (see ranging protocol for exact condition).
1.3.6.1.4.1.5504.5.12.1.7.1.6TruthValueread-onlycurrent
zhoneOnuStatusAlarmOAML
OBJECT-TYPE
PLOAM Cell Loss - When three consecutive PLOAM headers are wrong.
1.3.6.1.4.1.5504.5.12.1.7.1.7TruthValueread-onlycurrent
zhoneOnuStatusAlarmLCD
OBJECT-TYPE
Loss of Cell Delineation - When seven consecutive ATM cells have an invalid HEC.
1.3.6.1.4.1.5504.5.12.1.7.1.8TruthValueread-onlycurrent
zhoneOnuStatusAlarmFRML
OBJECT-TYPE
Loss Of Downstream Frame - When the frame bit is 0 for three consecutive frames.
1.3.6.1.4.1.5504.5.12.1.7.1.9TruthValueread-onlycurrent
zhoneOnuStatusAlarmERR
OBJECT-TYPE
Block Error Detection - The downstream received BIP8 is compared with the calculated BIP8 on the received stream. The number of differing bits is accumulated in ERR. At regular intervals, the content is sent via REI to the OLT. This interval is programmed by the OLT with a BER_interval_timer message. ERR is renewed at every reception of a downstream PLOAM cell.
1.3.6.1.4.1.5504.5.12.1.7.1.10TruthValueread-onlycurrent
zhoneOnuStatusAlarmSD
OBJECT-TYPE
Signal Degraded - Set active when the downstream BER >= 10E-5
1.3.6.1.4.1.5504.5.12.1.7.1.11TruthValueread-onlycurrent
zhoneOnuStatusAlarmMEM
OBJECT-TYPE
Message Error Message - When the ONU receives an unknown message.
1.3.6.1.4.1.5504.5.12.1.7.1.12TruthValueread-onlycurrent
zhoneOnuStatusAlarmDACT
OBJECT-TYPE
De-activate PON-ID - It instructs the ONU to deactivate itself.
1.3.6.1.4.1.5504.5.12.1.7.1.13TruthValueread-onlycurrent
zhoneOnuStatusAlarmDIS
OBJECT-TYPE
Disabled ONU - When the ONU receives a Disable_serial_number message with it's own serial number and the enable flag=0xFF. It stays in this state even after power off.
1.3.6.1.4.1.5504.5.12.1.7.1.14TruthValueread-onlycurrent
zhoneOnuStatusAlarmMIS
OBJECT-TYPE
Link Mismatching - The ONU detects that the received PST and transmitted PST are different.
1.3.6.1.4.1.5504.5.12.1.7.1.15TruthValueread-onlycurrent
zhoneOnuStatusLastChange
OBJECT-TYPE
Time of last line status change.
1.3.6.1.4.1.5504.5.12.1.7.1.16TimeStampread-onlycurrent
zhoneOltTrafficContainerIndexNext
OBJECT-TYPE
This object contains an appropriate value to be used for the zhoneOltTrafficContainerIndex when creating entries in the zhoneOltTrafficContainerTable. The value 0 indicates that no unassigned entries are available. To obtain the zhoneOltTrafficContainerIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
1.3.6.1.4.1.5504.5.12.1.8Integer32 (0..65535)read-onlycurrent
zhoneOltTrafficContainerTable
OBJECT-TYPE
Traffic Container definitions for the OLT.
1.3.6.1.4.1.5504.5.12.1.9not-accessiblecurrent
zhoneOltTrafficContainerEntry
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.12.1.9.1not-accessiblecurrent
zhoneOltTrafficContainerIndex
OBJECT-TYPE
A unique value to identify this traffic container entry.
1.3.6.1.4.1.5504.5.12.1.9.1.1Integer32 (1..65535)not-accessiblecurrent
zhoneOltTrafficContainerGuaranteedBW
OBJECT-TYPE
The maximum guareented bandwidth is downstream bit rate divided by number of ONUs. For this incarnation, it is 622 / 32 = 19.4
1.3.6.1.4.1.5504.5.12.1.9.1.2Unsigned32 (0..2147483647)read-createcurrent
zhoneOltTrafficContainerMaximumBW
OBJECT-TYPE
Maximum bandwidth for a PON channel. The maximum bandwidth is downstream bit rate divided by the number of ONUs. For this incarnation, it is 622 / 32 = 19.4
1.3.6.1.4.1.5504.5.12.1.9.1.3Unsigned32 (0..2147483647)read-createcurrent
zhoneOltTrafficContainerCBR
OBJECT-TYPE
Constant Bit Rate - describes the nature of the traffic on the channel. A TRUE setting implies that the data stream will be of a constant nature. FALSE implies that the traffic will be bursty.
1.3.6.1.4.1.5504.5.12.1.9.1.4TruthValueread-createcurrent
zhoneOltTrafficContainerCbrCompensate
OBJECT-TYPE
A flag for ranging compensation. When a ranging window is opened, the Grant Handler appends to the end of the ranging window all the grants missed due to the ranging window by CBR flows with the compensation flag set.
1.3.6.1.4.1.5504.5.12.1.9.1.5TruthValueread-createcurrent
zhoneOltTrafficContainerRowStatus
OBJECT-TYPE
Row status of the traffic container entry. This field must be initially set to 'createAndGo'.
1.3.6.1.4.1.5504.5.12.1.9.1.6ZhoneRowStatusread-createcurrent
zhoneAponTraps
OBJECT-IDENTITY
Definitions for Atm PON traps.
1.3.6.1.4.1.5504.5.12.3current
zhoneAPONV2Traps
OBJECT-IDENTITY
APON Olt and Onu Traps.
1.3.6.1.4.1.5504.5.12.3.0current

Notifications

NameOIDStatus
zhoneOltLineStatusChangeTrap
NOTIFICATION-TYPE
Line status change trap for the OLT APON interface.
1.3.6.1.4.1.5504.5.12.3.0.1current
zhoneOnuLineStatusChangeTrap
NOTIFICATION-TYPE
Line status change trap for a particular Onu APON interface.
1.3.6.1.4.1.5504.5.12.3.0.2current

Conformance

NameOIDStatus
zhoneAponOltConfigGroup
OBJECT-GROUP
OLT Config objects.
1.3.6.1.4.1.5504.9.1.2current
zhoneAponOltStatusGroup
OBJECT-GROUP
Zhone ATM-PON OLT Status objects.
1.3.6.1.4.1.5504.9.1.3current
zhoneAponOltOnuConfigGroup
OBJECT-GROUP
Zhone ATM-PON ONU Config objects.
1.3.6.1.4.1.5504.9.1.4current
zhoneAponOltOnuStatusGroup
OBJECT-GROUP
Zhone ATM-PON ONU Status objects.
1.3.6.1.4.1.5504.9.1.5current
zhoneAponOnuConfigGroup
OBJECT-GROUP
ONU configuration information.
1.3.6.1.4.1.5504.9.1.6current
zhoneAponOnuStatusGroup
OBJECT-GROUP
ONU status and alarm information.
1.3.6.1.4.1.5504.9.1.7current
zhoneAponOltTrafficContainerGroup
OBJECT-GROUP
OLT Traffic Container objects.
1.3.6.1.4.1.5504.9.1.8current
zhoneAponTrapsGroup
NOTIFICATION-GROUP
Atm PON traps group.
1.3.6.1.4.1.5504.9.1.9current