Zhone-PTP-MIB
- Registered at
- 1.3.6.1.4.1.5504.4.17.11.3.6.1.4.1.5504.6.119
- Last updated
- 2012-05-09 14:50
- Organization
- Zhone Technologies.
- Revisions
- 2013-05-09 15:15, 2012-01-13 14:50
- Namespace
- zhone
- Source file
Zhone-PTP-MIB- Digest
sha256:0e95183c78149c147f64eb100881b7ce037faa27e76698e9fdcdf6d9b931a6dc
Description
Managed data objects for Zhone's 1588 Precision Timing Protocol.
Contact
Contact-info.
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION |
| Zhone | zhoneGroups, zhoneModules, zhonePtp, zhoneShelfSlotGroup |
| Zhone-TC | ZhoneRowStatus |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC Zhone Zhone-PTP-MIB Zhone-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| zhonePtpObjectID OBJECT-IDENTITY | 1.3.6.1.4.1.5504.4.17.1 | |||
| zhonePtpConfigTable OBJECT-TYPE Table of configuration values for the Precision Timing Protocol. | 1.3.6.1.4.1.5504.4.17.1.1 | not-accessible | current | |
| zhonePtpConfigEntry OBJECT-TYPE Row in the PtpConfigTable | 1.3.6.1.4.1.5504.4.17.1.1.1 | not-accessible | current | |
| zhonePtpConfigIfIndex OBJECT-TYPE Index for this table. | 1.3.6.1.4.1.5504.4.17.1.1.1.1 | InterfaceIndex | not-accessible | current |
| zhonePtpConfigClockMode OBJECT-TYPE Describes the mode and function of this clock. | 1.3.6.1.4.1.5504.4.17.1.1.1.2 | INTEGER {master(1), slave(2), boundary(3), transparent(4), forward(5)} | read-create | current |
| zhonePtpConfigSyncMsgInterval OBJECT-TYPE Log of mean time interval between successive Sync messages when transmitted as multicast messages. | 1.3.6.1.4.1.5504.4.17.1.1.1.3 | Integer32 (-128..127) | read-create | current |
| zhonePtpConfigAnnounceInterval OBJECT-TYPE Log of time, in seconds, to send announce messages. | 1.3.6.1.4.1.5504.4.17.1.1.1.4 | Integer32 (-128..127) | read-create | current |
| zhonePtpConfigDelayReqInterval OBJECT-TYPE Log of minimum permitted mean time between successive Delay_Req messages sent by a slave to a specific port on the master. | 1.3.6.1.4.1.5504.4.17.1.1.1.5 | Integer32 (-128..127) | read-create | current |
| zhonePtpConfigDomain1MS OBJECT-TYPE The domain for this PTP. If clockMode is boundary, then this is the domain for the slave port. | 1.3.6.1.4.1.5504.4.17.1.1.1.6 | Unsigned32 (0..255) | read-create | current |
| zhonePtpConfigVariance OBJECT-TYPE Log of variance used in determination of the best master clock. | 1.3.6.1.4.1.5504.4.17.1.1.1.7 | Unsigned32 (0..65535) | read-create | current |
| zhonePtpConfigPriority1 OBJECT-TYPE Precedence value used in best master algorithm, if master. | 1.3.6.1.4.1.5504.4.17.1.1.1.8 | Unsigned32 (0..255) | read-create | current |
| zhonePtpConfigPriority2 OBJECT-TYPE Precedence used in best master determination, if master | 1.3.6.1.4.1.5504.4.17.1.1.1.9 | Unsigned32 (0..255) | read-create | current |
| zhonePtpConfigDomain2M OBJECT-TYPE If clockMode is boundary, then this is the domain for the master port. Otherwise, it is unused. | 1.3.6.1.4.1.5504.4.17.1.1.1.10 | Integer32 (0..255) | read-create | current |
| zhonePtpConfigRowStatus OBJECT-TYPE Row status for this table. | 1.3.6.1.4.1.5504.4.17.1.1.1.11 | ZhoneRowStatus | read-create | current |
| zhonePtpConfigIpIfIndex OBJECT-TYPE The management ip index on this system. | 1.3.6.1.4.1.5504.4.17.1.1.1.12 | InterfaceIndex | read-create | current |
| zhonePtpConfigAcceptableMaster1 OBJECT-TYPE First acceptable PTP master. | 1.3.6.1.4.1.5504.4.17.1.1.1.13 | IpAddress | read-create | current |
| zhonePtpConfigAcceptableMaster2 OBJECT-TYPE Second acceptable PTP master. | 1.3.6.1.4.1.5504.4.17.1.1.1.14 | IpAddress | read-create | current |
| zhonePtpStatusTable OBJECT-TYPE The read-only attributes associated with the 1588 module. | 1.3.6.1.4.1.5504.4.17.1.2 | not-accessible | current | |
| zhonePtpStatusEntry OBJECT-TYPE A row in the zhonePtpStatusTable | 1.3.6.1.4.1.5504.4.17.1.2.1 | not-accessible | current | |
| zhonePtpStatusMacAddress OBJECT-TYPE The ptpMacAddr is used to set the PTP ClockIdentifier defined in the PTP standard. It identifies the clock in the PTP network and as such should be unique within the PTP network. | 1.3.6.1.4.1.5504.4.17.1.2.1.1 | MacAddress | read-only | current |
| zhonePtpConfigTimeSource OBJECT-TYPE Time source for the PTP. | 1.3.6.1.4.1.5504.4.17.1.2.1.2 | INTEGER {atom(1), gps(2), radio(3), ptp(4), ntp(5), handSet(6), other(7), internalOscillator(8)} | read-only | current |
| zhonePtpConfigClockStratum OBJECT-TYPE Indicates the stratum level of the local clock. | 1.3.6.1.4.1.5504.4.17.1.2.1.3 | INTEGER {force(1), primaryReference(2), secondaryReference(3), bestClockStratumThatCanBeSlave(4), stratum3(5), stratum4(6), defaultStratum(7)} | read-only | current |
| zhonePtpConfigClockAccuracy OBJECT-TYPE Accuracy of this clock. Used in determining best master clock. | 1.3.6.1.4.1.5504.4.17.1.2.1.4 | INTEGER {nSec25(1), nSec100(2), nSec250(3), uSec1(4), uSec2point5(5), uSec10(6), uSec25(7), uSec100(8), uSec250(9), mSec1(10), mSec2point5(11), mSec10(12), mSec25(13), mSec100(14), mSec250(15), sec1(16), sec10(17), gT10S(18), accUnknown(19)} | read-only | current |
| zhonePtpStatusTxMode OBJECT-TYPE By default, Semtech sends multicast messages (e.g. Announce Messages) if they are meant for more than one node. Messages destined to a single node are sent as unicast messages. If we want to support Acceptable Master and Slave tables, we need the uniOnly option. | 1.3.6.1.4.1.5504.4.17.1.2.1.5 | INTEGER {standard(1), uniOnly(2), multiOnly(3)} | read-only | current |
Conformance
| Name | OID | Status |
|---|---|---|
| zhonePtpGroup OBJECT-GROUP Object groups for ptp objects. | 1.3.6.1.4.1.5504.9.1.52 | current |