MIBs Depot

Zhone-GPON-MIB

Registered at
1.3.6.1.4.1.5504.5.14.1
1.3.6.1.4.1.5504.6.111
Last updated
2014-10-29 02:19
Organization
Zhone Technologies, Inc.
Revisions
2014-10-29 02:19, 2014-10-17 01:53, 2014-06-11 17:38, 2014-05-27 10:37, 2014-01-22 16:52, 2013-12-19 14:08, 2013-12-12 15:25, 2013-10-02 15:45, 2013-06-10 12:25, 2013-05-16 14:25, 2013-05-08 16:01, 2013-05-01 14:25, 2012-12-05 11:54, 2012-10-19 14:24, 2012-10-09 09:16, 2012-08-23 14:53, 2011-11-10 18:14, 2011-10-17 19:43, 2011-06-14 15:04, 2011-06-02 19:02, 2011-04-08 09:50, 2011-03-14 12:00, 2011-03-01 10:49, 2011-02-08 17:08, 2011-01-24 16:56, 2011-01-17 11:36, 2010-11-04 10:36, 2010-10-28 14:49, 2010-10-19 14:40, 2010-09-08 10:18, 2010-09-01 16:25, 2010-09-01 12:10, 2010-08-13 15:29, 2010-08-10 16:35, 2010-07-27 08:08, 2010-07-19 14:23, 2010-06-11 14:21, 2010-06-01 18:02, 2010-05-13 09:02, 2010-05-12 09:00, 2010-04-13 11:19, 2010-04-05 11:37, 2010-03-31 07:52, 2010-03-16 11:33, 2010-01-13 13:01, 2009-12-16 07:32, 2009-11-14 09:54, 2009-11-13 09:13, 2009-10-09 11:31, 2009-09-24 13:04, 2009-09-18 18:40, 2009-09-16 07:19, 2009-09-15 11:00, 2009-09-14 06:38, 2009-08-28 14:45, 2009-08-19 12:24, 2009-07-31 06:32, 2009-07-16 10:02, 2009-07-07 11:12, 2009-06-16 08:36, 2009-06-11 15:49, 2009-05-22 15:53, 2009-05-18 15:08, 2009-02-18 11:38, 2009-01-15 07:04, 2009-01-06 11:33, 2008-12-10 09:42, 2008-11-11 14:07, 2008-10-09 17:08, 2008-09-22 07:55, 2008-08-12 07:39, 2008-06-25 14:49, 2008-06-12 17:37, 2008-05-23 15:39, 2007-08-22 17:34, 2007-03-19 17:35, 2007-03-01 19:27, 2006-10-27 16:06
Namespace
zhone
Source file
Zhone-GPON-MIB
Digest
sha256:5e6e25eb76b1cf44056d206136fe2db4af660548159a4ac246d79f98f75b1adc

Description

This is the Zhone GPON mib which contains SNMP objects for GPON ONU configuration, alarms, and status.It also includes the GPON OLT status information.

Contact

Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue
ZhoneapsMIB, efmCuMIB, efmOamMIB, pktcIetfSigMib, sechtor100, sechtor300, sipCommonMIB, sipTC, sipUAMIB, zhoneApon, zhoneAtm, zhoneBonding, zhoneBridge, zhoneCard, zhoneCes, zhoneClass5, zhoneConsole, zhoneDrafts, zhoneDs3Ext, zhoneDsl, zhoneDsx, zhoneEnet, zhoneGenWtn, zhoneGpon, zhoneGroups, zhoneIma, zhoneInterfaceGroup, zhoneInterfaceTranslation, zhoneIp, zhoneIsdn, zhoneLineTypes, zhoneMalc, zhoneMasterAgent, zhoneModules, zhoneOcx, zhonePls, zhonePpp, zhoneRadio, zhoneRegCpe, zhoneRegMalc, zhoneRegMux, zhoneRegPls, zhoneRegSechtor, zhoneRegWtn, zhoneShelf, zhoneShelfIndex, zhoneShelfSlotCompliance, zhoneShelfSlotGroup, zhoneSlotIndex, zhoneSonet, zhoneSs7, zhoneSubscriber, zhoneSystem, zhoneTrapModules, zhoneVdsl, zhoneVideo, zhoneVoice, zhoneVoiceStats, zhoneVoip, zhoneWtn, zhoneZAP, zhoneZedge, zhoneZmsProduct, zhoneZplex
Zhone-TCZhoneAdminString, ZhoneEnabledFlag, ZhoneRowStatus

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
Zhone
Zhone-GPON-MIB
Zhone-TC

Textual conventions

NameOIDSyntaxAccessStatus
GponCacRc
TEXTUAL-CONVENTION
This object contains the result code of the last GPON CAC request for the OLT. ok - GPON CAC requrest approved noReq - GPON CAC request has not been performed badParms - Internal error. Bad pointer or index value parameter to a GPON CAC procedure call cfgLookup - Internal error. Failed to look up a config record ( OLT, ONU, traffic profile, etc ) genError - Internal error. Invalid value was found inside a profile so a switch statement failed maxOnuGemPorts - Each ONU supports a limited number of GEM ports maxOltAllocIds - Each OLT supports a limited number of allocIds maxOltDbaAllocIds - Each OLT supports a limited number of DBA-enabled allocIds maxBw - An attempt was made to create a new GEM port or modifying an existing GEM port but the there is no available total bandwidth maxCbrBw - An attempt was made to create a new GEM port or modifying an existing GEM port but the there is no available CBR bandwidth trafficClassChg - An attempt was made to change a GEM port traffic profile index. The change was not allowed because the new traffic profile has a different traffic class dbaStatusChg - An attempt was made to change a GEM port traffic profile index. The change was not allowed because the new traffic profile has a different DBA Enabled status testCreateInvalidParms - GEM Port cannot be created because there are invalid paramater values used to create the GEM Port. testCreateMissingParms - GEM Port cannot be created because there are missing paramater values used to create the GEM Port. testCreateAlreadyExistsIfIndex - GEM Port cannot be created because a GEM Port already exists with the specified ifIndex testCreateAlreadyExistsSSPS - GEM Port cannot be created because a GEM Port already exists with the specified shelf, slot, port and subPort values. testCreateOnuDoesNotExist - GEM Port cannot be created because the specified GEM Port ONU does not exist testCreateOnuNotRegistered - GEM Port cannot be created because the GEM Port ONU has not been registered with the LINERR testCreateCannotFindPrimary - GEM Port cannot be created because the GEM Port Primary OLT cannot be located testCreateCannotAddToSecondary - GEM Port cannot be created on the secondary OLT of an OLT line redundancy group
current
OnuUpgradeState
TEXTUAL-CONVENTION
Onu upgrade state, for queries and reporting.
current

Objects

NameOIDSyntaxAccessStatus
zhoneGponObjectID
OBJECT-IDENTITY
1.3.6.1.4.1.5504.5.14.1
zhoneGponOltConfigTable
OBJECT-TYPE
Configuration parameters that apply to one OLT. This profile is auto-created.
1.3.6.1.4.1.5504.5.14.1.1not-accessiblecurrent
zhoneGponOltConfigEntry
OBJECT-TYPE
One row of the gpon olt config entry table.
1.3.6.1.4.1.5504.5.14.1.1.1not-accessiblecurrent
zhoneGponOltIfIndex
OBJECT-TYPE
The ifIndex of the physical olt interface.
1.3.6.1.4.1.5504.5.14.1.1.1.1InterfaceIndexnot-accessiblecurrent
zhoneGponOltConfigMaxRtPropagationDelay
OBJECT-TYPE
Maximum round trip propagation delay. Combined with max ONU response time and preassigned delay determins maximum logical PON distance. Default 200 usec for 20 dm.
1.3.6.1.4.1.5504.5.14.1.1.1.2Integer32read-writecurrent
zhoneGponOltConfigMaxOnuResponseTime
OBJECT-TYPE
Combined with max rt propagation delay, determins maximum logical PON distance.
1.3.6.1.4.1.5504.5.14.1.1.1.3Integer32read-writecurrent
zhoneGponOltConfigPreassignedEqD
OBJECT-TYPE
Combined with max rt propagation delay and max onu response time determines max logical PON distance.
1.3.6.1.4.1.5504.5.14.1.1.1.4Integer32read-writecurrent
zhoneGponOltConfigLosAlpha
OBJECT-TYPE
Number of loss-of-signal occurrences to trigger alarm.
1.3.6.1.4.1.5504.5.14.1.1.1.5Integer32read-writecurrent
zhoneGponOltConfigLofAlpha
OBJECT-TYPE
Number of loss-of-frame occurrences to trigger alarm.
1.3.6.1.4.1.5504.5.14.1.1.1.6Integer32read-writecurrent
zhoneGponOltConfigLoamAlpha
OBJECT-TYPE
Number of loss-of-OAM occurrences to trigger alarm.
1.3.6.1.4.1.5504.5.14.1.1.1.7Integer32read-writecurrent
zhoneGponOltConfigScrambler
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.14.1.1.1.8ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigFecMode
OBJECT-TYPE
Enables or disables forward error correction.
1.3.6.1.4.1.5504.5.14.1.1.1.9ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigAutoLearn
OBJECT-TYPE
Enable or disable password auto-learn mode.
1.3.6.1.4.1.5504.5.14.1.1.1.10ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigPowerLevel
OBJECT-TYPE
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
1.3.6.1.4.1.5504.5.14.1.1.1.11Unsigned32read-writecurrent
zhoneGponOltConfigGuardBitCount
OBJECT-TYPE
Number of guard bits for upstream transmission.
1.3.6.1.4.1.5504.5.14.1.1.1.12Integer32read-writecurrent
zhoneGponOltConfigDbaMode
OBJECT-TYPE
Working DBA mode.
1.3.6.1.4.1.5504.5.14.1.1.1.13INTEGER {predictive(1), piggyback(2), wholeReport(3)}read-writecurrent
zhoneGponOltConfigGemBlockSize
OBJECT-TYPE
Basic unit in bytes used by all ONUs for DBA reports of their queue occupancy (for piggyback and whole-report DBA only).
1.3.6.1.4.1.5504.5.14.1.1.1.14Integer32read-writecurrent
zhoneGponOltConfigUsBerInterval
OBJECT-TYPE
Interval for upstream bit error rate calculation.
1.3.6.1.4.1.5504.5.14.1.1.1.15Integer32read-writecurrent
zhoneGponOltConfigDsBerInterval
OBJECT-TYPE
Interval used for downstream bit error rate calculation.
1.3.6.1.4.1.5504.5.14.1.1.1.16Integer32read-writecurrent
zhoneGponOltConfigBerSfThreshold
OBJECT-TYPE
Threshold is 10**(-N) for signal fail.
1.3.6.1.4.1.5504.5.14.1.1.1.17Integer32 (3..8)read-writecurrent
zhoneGponOltConfigBerSdThreshold
OBJECT-TYPE
Threshold is 10**(-N) for signal degrade. Must exceed sf threshold.
1.3.6.1.4.1.5504.5.14.1.1.1.18Integer32 (4..9)read-writecurrent
zhoneGponOltConfigFecRequest
OBJECT-TYPE
Indicates whether OLT turns on FEC indication for all Alloc-Id in the Upstream Bandwidth Map.
1.3.6.1.4.1.5504.5.14.1.1.1.19ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigKeyExchange
OBJECT-TYPE
Specifies whether Single Key exchange should be performed during ONU activation process.
1.3.6.1.4.1.5504.5.14.1.1.1.20ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigMinRtPropagationDelay
OBJECT-TYPE
If closest ONU location is known, GPON_stack uses this value in order to limit the size of the quiet zone.
1.3.6.1.4.1.5504.5.14.1.1.1.21Integer32read-writecurrent
zhoneGponOltConfigMinOnuResponseTime
OBJECT-TYPE
GPON_stack uses this value in order to limit the size of the quiet zone.
1.3.6.1.4.1.5504.5.14.1.1.1.22Integer32read-writecurrent
zhoneGponOltConfigEqDMeasureCycles
OBJECT-TYPE
Defines the number of measurement cycles in the Ranging process.
1.3.6.1.4.1.5504.5.14.1.1.1.23Integer32read-writecurrent
zhoneGponOltConfigDriftControlInterval
OBJECT-TYPE
Defines the interval of periodic monitoring on drifts of upstream data.
1.3.6.1.4.1.5504.5.14.1.1.1.24Integer32read-writecurrent
zhoneGponOltConfigDriftControlLimit
OBJECT-TYPE
Indicates the limit of upstream data drift.
1.3.6.1.4.1.5504.5.14.1.1.1.25Integer32read-writecurrent
zhoneGponOltConfigAllocCycleLength
OBJECT-TYPE
Alloc-ID assignment map cycle length.
1.3.6.1.4.1.5504.5.14.1.1.1.26Integer32 (1..10)read-writecurrent
zhoneGponOltConfigMinUsAlloc
OBJECT-TYPE
Size of minimal upstream allocation per frame.
1.3.6.1.4.1.5504.5.14.1.1.1.27Integer32read-writecurrent
zhoneGponOltConfigAckTimeout
OBJECT-TYPE
Timeout length of Acknowledge message.
1.3.6.1.4.1.5504.5.14.1.1.1.28Integer32read-writecurrent
zhoneGponOltConfigPlsMaxAllocSize
OBJECT-TYPE
Indecates a size of unassigned allocation that should be attached to the end of ranging window.
1.3.6.1.4.1.5504.5.14.1.1.1.29Integer32read-writecurrent
zhoneGponOltConfigDbaCycle
OBJECT-TYPE
The Dynamic Bandwidth Allocation(dba) cycle determines the DBA interval size. Its an integer multiplicant of 2 milli seconds. The range of values for the dba cycle can be between 2ms-10ms.
1.3.6.1.4.1.5504.5.14.1.1.1.30Unsigned32 (2..10)read-writecurrent
zhoneGponOltConfigSrDbaReportingBlockSize
OBJECT-TYPE
For DBA of SR type, the block size defines the resolution of the status reports per PON link.The default value is 48 bytes.
1.3.6.1.4.1.5504.5.14.1.1.1.31Unsigned32read-writecurrent
zhoneGponOltConfigProtectionSwitchoverTimer
OBJECT-TYPE
If we receive LOS alarm for a link in Active state, the link state changes to Switch Over Pending state. If the actual switch-over does not happen after this protection-switchover-timeout expires, the link will go back to Active state
1.3.6.1.4.1.5504.5.14.1.1.1.32Unsigned32read-writecurrent
zhoneGponOltConfigPreambleOverride
OBJECT-TYPE
Used to force the OLT to use the Preamble configuration in the OLT configuration profile. Otherwise the Preamble configuration will be determined at runtime and based on the SFP.
1.3.6.1.4.1.5504.5.14.1.1.1.33ZhoneEnabledFlagread-writecurrent
zhoneGponOltConfigPreambleType0
OBJECT-TYPE
Byte number for preamble type 0. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
1.3.6.1.4.1.5504.5.14.1.1.1.34OCTET STRING (SIZE(0..4))read-writecurrent
zhoneGponOltConfigPreambleType1
OBJECT-TYPE
Byte number for preamble type 1. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
1.3.6.1.4.1.5504.5.14.1.1.1.35OCTET STRING (SIZE(0..4))read-writecurrent
zhoneGponOltConfigPreambleType3PreRange
OBJECT-TYPE
Byte number for preamble type 3 pre-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
1.3.6.1.4.1.5504.5.14.1.1.1.36OCTET STRING (SIZE(0..4))read-writecurrent
zhoneGponOltConfigPreambleType3PostRange
OBJECT-TYPE
Byte number for preamble type 3 post-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
1.3.6.1.4.1.5504.5.14.1.1.1.37OCTET STRING (SIZE(0..4))read-writecurrent
zhoneGponOltConfigPreambleType3Pattern
OBJECT-TYPE
Preamble type 3 pattern. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
1.3.6.1.4.1.5504.5.14.1.1.1.38OCTET STRING (SIZE(0..4))read-writecurrent
zhoneGponOltConfigBipErrorMonitoring
OBJECT-TYPE
If in disabled mode, do not report BIP errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor BIP errors and if BIP Error Threshold exceeded, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors and throw zhoneGponOnuError trap. If in blockOnError mode, monitor BIP errors and if BIP Error Threshold exceeded, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors, and throw zhoneGponOnuError and linkDownTrap traps.
1.3.6.1.4.1.5504.5.14.1.1.1.39INTEGER {disabled(1), monitorOnly(2), blockOnError(3)}read-writecurrent
zhoneGponOltConfigBipErrorsPerSampleThreshold
OBJECT-TYPE
If the number of BIP errors per sample exceeds this threshold, it is counted as an errored sample.
1.3.6.1.4.1.5504.5.14.1.1.1.40Integer32read-writecurrent
zhoneGponOltConfigBipErroredSamplesThreshold
OBJECT-TYPE
If the number of errored samples exceed this sample threshold, report and disable the onu if in blockOnError mode, otherwise simply report the threshold as being exceeded.
1.3.6.1.4.1.5504.5.14.1.1.1.41Integer32read-writecurrent
zhoneGponOltConfigBipMaxSampleGap
OBJECT-TYPE
If two adjancent errored samples were taken farther apart than this threshold, do not count the earlier sample as an errored sample.
1.3.6.1.4.1.5504.5.14.1.1.1.42Integer32read-writecurrent
zhoneGponOltConfigRogueOnuDetection
OBJECT-TYPE
Controls detection of rogue ONU on fiber. Values are: 1. detection disabled 2. detect via measurement from rssi process 3. detect via indication from background process. 4. normally off, but switch to rssi mode if rogue is suspected.
1.3.6.1.4.1.5504.5.14.1.1.1.43INTEGER {disabled(1), rogueRssi(2), backgroundProcess(3), autoRssi(4)}read-writecurrent
zhoneGponOltConfigRogueOnuDetectFrequency
OBJECT-TYPE
Frequency in seconds for detection background task.
1.3.6.1.4.1.5504.5.14.1.1.1.44Integer32 (1..60)read-writecurrent
zhoneGponOltConfigRogueOnuRxPowerThreshold
OBJECT-TYPE
Power level below which to report rssi rogue ONU.
1.3.6.1.4.1.5504.5.14.1.1.1.45Integer32read-writecurrent
zhoneGponOltOnuConfigTable
OBJECT-TYPE
Configuration parameters applying to a single onu stacked on an olt. This profile is auto-created.
1.3.6.1.4.1.5504.5.14.1.2not-accessiblecurrent
zhoneGponOltOnuConfigEntry
OBJECT-TYPE
A row in the gpon olt-onu config table.
1.3.6.1.4.1.5504.5.14.1.2.1not-accessiblecurrent
zhoneGponOltOnuIfIndex
OBJECT-TYPE
IfIndex of the onu interface stacked on the olt.
1.3.6.1.4.1.5504.5.14.1.2.1.1InterfaceIndexnot-accessiblecurrent
zhoneGponOltOnuConfigSerialNoVendorId
OBJECT-TYPE
This is a string of 4 ascii characters representing the vendor ID portion of the onu serial number. Example: 'ZNTS' for Zhone.
1.3.6.1.4.1.5504.5.14.1.2.1.2ZhoneAdminString (SIZE(0..4))read-writecurrent
zhoneGponOltOnuConfigSerialNoVendorSpecific
OBJECT-TYPE
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number.
1.3.6.1.4.1.5504.5.14.1.2.1.3ZhoneAdminString (SIZE(1..10))read-writecurrent
zhoneGponOltOnuConfigPassword
OBJECT-TYPE
Password (10 bytes).
1.3.6.1.4.1.5504.5.14.1.2.1.4ZhoneAdminString (SIZE(0..10))read-writecurrent
zhoneGponOltOnuConfigAutoLearn
OBJECT-TYPE
Indicates whether password is auto-learned.
1.3.6.1.4.1.5504.5.14.1.2.1.5ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigPowerLevel
OBJECT-TYPE
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
1.3.6.1.4.1.5504.5.14.1.2.1.6Integer32read-writecurrent
zhoneGponOltOnuConfigUsBerInterval
OBJECT-TYPE
Interval for upstream bit error rate calculation.
1.3.6.1.4.1.5504.5.14.1.2.1.7Integer32read-writecurrent
zhoneGponOltOnuConfigDsBerInterval
OBJECT-TYPE
Interval for downstream bit error rate.
1.3.6.1.4.1.5504.5.14.1.2.1.8Integer32read-writecurrent
zhoneGponOltOnuConfigOnuAdded
OBJECT-TYPE
Indicates to Broadlight that onu is activated. May not be used.
1.3.6.1.4.1.5504.5.14.1.2.1.9TruthValueread-writecurrent
zhoneGponOltOnuConfigOmciFileName
OBJECT-TYPE
Name of OMCI configuration file for this ONT.
1.3.6.1.4.1.5504.5.14.1.2.1.10ZhoneAdminStringread-writecurrent
zhoneGponOltOnuConfigMEProfileName
OBJECT-TYPE
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain OMCI commands that configure the Managed Entities (ME) on an ONU.
1.3.6.1.4.1.5504.5.14.1.2.1.11ZhoneAdminStringread-writecurrent
zhoneGponOltOnuConfigGenericProfileName
OBJECT-TYPE
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain generic commands that are common to multiple ONUs.
1.3.6.1.4.1.5504.5.14.1.2.1.12ZhoneAdminStringread-writecurrent
zhoneGponOltOnuConfigPhysicalTraps
OBJECT-TYPE
If enabled, then an asynchronous notification from the ONT with ME class ONT-G triggers an omciOnuAlarms trap. The alarm conditions for this ME class are: equipment alarm, powering alarm, battery missing, battery failure, battery low, physical intrusion alarm, and self-test failure.
1.3.6.1.4.1.5504.5.14.1.2.1.13ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigOntTraps
OBJECT-TYPE
If enabled, then an asynchronous notification from the ONT with ME class other than ONT-G triggers an omciOnuAlarms trap.
1.3.6.1.4.1.5504.5.14.1.2.1.14ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigLineStatusTraps
OBJECT-TYPE
If enabled, then gponOnuLineStatusChange traps, and also LinkUp/LinkDown traps, are sent whenever line status changes between up and down. If disabled, none of these traps is sent. If auto, then line status traps are sent if the 'dying gasp' flag is on (for line down), or if the 'dying gasp' flag was on (for line up). Link down/up traps are not sent.
1.3.6.1.4.1.5504.5.14.1.2.1.15INTEGER {enabled(1), disabled(2), auto(3), linkonly(4)}read-writecurrent
zhoneGponOltOnuConfigAutoUpgrade
OBJECT-TYPE
If enabled, then the ONU s/w will be upgraded if the ONU version does not match the assoicated remote upgrade profile. Changing this variable to disabled will not abort a remote software upgrade already in progress.
1.3.6.1.4.1.5504.5.14.1.2.1.16ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigSerialNoVendorSpecificFsan
OBJECT-TYPE
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number in hex format ( FSAN ).
1.3.6.1.4.1.5504.5.14.1.2.1.17OCTET STRING (SIZE(0..9))read-writecurrent
zhoneGponOltOnuConfigUseRegId
OBJECT-TYPE
If enabled, and if the onu is activated, then when an ONT is discovered with a registration ID that matches this ONU's password field, then the ONU will be auto-assigned to that ONT.
1.3.6.1.4.1.5504.5.14.1.2.1.18ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigModel
OBJECT-TYPE
Model ID returned from this Onu.
1.3.6.1.4.1.5504.5.14.1.2.1.19OCTET STRING (SIZE(0..20))read-onlycurrent
zhoneGponOltOnuConfigOntVersion
OBJECT-TYPE
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
1.3.6.1.4.1.5504.5.14.1.2.1.20OCTET STRING (SIZE(0..14))read-onlycurrent
zhoneGponOltOnuConfigImageVersionActive
OBJECT-TYPE
Version information for the active s/w image.
1.3.6.1.4.1.5504.5.14.1.2.1.21OCTET STRING (SIZE(0..64))read-onlycurrent
zhoneGponOltOnuConfigImageVersionStandby
OBJECT-TYPE
Version information for the standby s/w image.
1.3.6.1.4.1.5504.5.14.1.2.1.22OCTET STRING (SIZE(0..64))read-onlycurrent
zhoneGponOltOnuConfigUsRxPowerMonitoring
OBJECT-TYPE
If in disabled mode, do not report Upstream Onu Rx Power errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, set appropriate zhoneGponOnuStatusWord bits and throw zhoneGponOnuError trap. If in blockOnError mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits and throw both zhoneGponOnuError and linkDownTrap traps.
1.3.6.1.4.1.5504.5.14.1.2.1.23INTEGER {disabled(1), monitorOnly(2), blockOnError(3)}read-writecurrent
zhoneGponOltOnuConfigUsRxPowerHighThreshold
OBJECT-TYPE
Upstream Receive Power High Threshold value.
1.3.6.1.4.1.5504.5.14.1.2.1.24Integer32read-writecurrent
zhoneGponOltOnuConfigUsRxPowerLowThreshold
OBJECT-TYPE
Upstream Receive Power Low Threshold value.
1.3.6.1.4.1.5504.5.14.1.2.1.25Integer32read-writecurrent
zhoneGponOltOnuConfigDbaStatusReporting
OBJECT-TYPE
There are two types of DBA, Status Reporting and Non Status Reporting. The value is enabled or disabled. The default is disabled.
1.3.6.1.4.1.5504.5.14.1.2.1.26ZhoneEnabledFlagread-writecurrent
zhoneGponOltOnuConfigOmciDataSync
OBJECT-TYPE
If the MIB data sync value returned from the ONU on a MIB audit matches the MXK value, config not required.
1.3.6.1.4.1.5504.5.14.1.2.1.27Unsigned32read-onlycurrent
zhoneGponOltOnuConfigSnmpDataSync
OBJECT-TYPE
If the SNMP provisioning change value returned from the CPE matches the MXK value, config not required.
1.3.6.1.4.1.5504.5.14.1.2.1.28Unsigned32read-onlycurrent
zhoneGponOltOnuConfigNextAvailableGemPort
OBJECT-TYPE
Next available GEM PORT for the ONU.
1.3.6.1.4.1.5504.5.14.1.2.1.29Integer32 (257..3828)read-onlycurrent
zhoneGponOltOnuConfigAutoConfigState
OBJECT-TYPE
Track whether the ONU has been auto-configured.
1.3.6.1.4.1.5504.5.14.1.2.1.30INTEGER {init(1), done(2), disabled(3), error(4)}read-onlycurrent
zhoneGponOltOnuConfigLinkStatusAlarmSeverity
OBJECT-TYPE
Based on the severity set in this field LinkUp/LinkDown alarms are raised.
1.3.6.1.4.1.5504.5.14.1.2.1.31INTEGER {critical(1), major(2), minor(3)}read-writecurrent
zhoneGponPortConfigTable
OBJECT-TYPE
The gpon port is similiar to VCLs in ATM. Data is transferred between OLT and ONU via ports. This profile is dynamically created during CLI bridge-add, host-add, interface-add commands but must be explicitly created during SNMP operation. GEM ports can be created using a supplied I/F index value or using the next available I/F index value. Since the GEM Port is a virtual device, ZMS prefers to supply the I/F index value because ZMS cannot lookup the newly created GEM port using shelf/slot/olt/port indexing ( virual devices do not support these values). How to create a GEM port using next available I/F Index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Next of the object ifIndexNext to determine the I/F index value of the new GEM port. The SNMP-Next will not result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.1 = create zhoneGponPortConfigRowShelf.1 = 1 zhoneGponPortConfigRowSlot.1 = GEM port slot zhoneGponPortConfigRowOlt.1 = GEM port OLT zhoneGponPortConfigRowPort.1 = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.1 = traffic profile The GEM port will be created using the next available ifIndex. How to create a GEM port with a specified I/F index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Get of the object ifIndexNext to determine the next available I/F index value. The SNMP-Get will result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = create zhoneGponPortConfigRowShelf.aaa = 1 zhoneGponPortConfigRowSlot.aaa = GEM port slot zhoneGponPortConfigRowOlt.aaa = GEM port OLT zhoneGponPortConfigRowPort.aaa = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.aaa = traffic profile where aaa is the I/F index value collected in step 1. A GEM Port cannot be created if an I/F translate record already exists using the supplied I/F index value. How to delete a GEM port using a single SNMP packet: 1. Determine I/F index of GEM port config profile (aaa) 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = destroy Special Notes: 1. The deletion of a GEM port will be prevented if the GEM port supports bridges, interfaces, etc. 2. The GEM port ID value determines the GEM port ONU.
1.3.6.1.4.1.5504.5.14.1.3not-accessiblecurrent
zhoneGponPortConfigEntry
OBJECT-TYPE
A row in the gpon port config table.
1.3.6.1.4.1.5504.5.14.1.3.1not-accessiblecurrent
zhoneGponPortIfIndex
OBJECT-TYPE
The ifIndex of the gpon-port interface stacked on the olt.
1.3.6.1.4.1.5504.5.14.1.3.1.1InterfaceIndexnot-accessiblecurrent
zhoneGponPortConfigRowStatus
OBJECT-TYPE
The row status for the port config table.
1.3.6.1.4.1.5504.5.14.1.3.1.2ZhoneRowStatusread-createcurrent
zhoneGponPortConfigMulticast
OBJECT-TYPE
Specifies whether this is a multicast or unicast port. If unicast, only one onu may be given, and the unicast-onu-id field is used. If multicast is true, then the multicast-onu-ids is used to name the onus.
1.3.6.1.4.1.5504.5.14.1.3.1.3TruthValueread-createcurrent
zhoneGponPortConfigEncrypted
OBJECT-TYPE
Specifies whether port-id PLOAM messages are encrypted. Must be false if multicast.
1.3.6.1.4.1.5504.5.14.1.3.1.4TruthValueread-createcurrent
zhoneGponPortConfigDirection
OBJECT-TYPE
Direction of data for this port.
1.3.6.1.4.1.5504.5.14.1.3.1.5INTEGER {down(1), up(2), bidirectional(3)}read-createcurrent
zhoneGponPortConfigTrafficProfile
OBJECT-TYPE
Index of GEM Port traffic profile for this port. A zero value indicates no GEM Port traffic profile has been selected.
1.3.6.1.4.1.5504.5.14.1.3.1.6Unsigned32read-createcurrent
zhoneGponPortConfigRowShelf
OBJECT-TYPE
This is a WRITE-ONLY variable used during port create/delete operations.
1.3.6.1.4.1.5504.5.14.1.3.1.7Unsigned32read-createcurrent
zhoneGponPortConfigRowSlot
OBJECT-TYPE
This is a WRITE-ONLY variable used during port create/delete operations.
1.3.6.1.4.1.5504.5.14.1.3.1.8Unsigned32read-createcurrent
zhoneGponPortConfigRowOlt
OBJECT-TYPE
This is a WRITE-ONLY variable used during port create/delete operations.
1.3.6.1.4.1.5504.5.14.1.3.1.9Unsigned32read-createcurrent
zhoneGponPortConfigRowPort
OBJECT-TYPE
This is a WRITE-ONLY variable used during port create/delete operations.
1.3.6.1.4.1.5504.5.14.1.3.1.10Unsigned32read-createcurrent
zhoneGponPortConfigRowTrafficProfile
OBJECT-TYPE
This is a WRITE-ONLY variable used during port create/delete operations.
1.3.6.1.4.1.5504.5.14.1.3.1.11Unsigned32read-createcurrent
zhoneGponPortConfigRowOnuId
OBJECT-TYPE
The subPort of the ONU on which this GEM port is to be stacked. This is a write-only variable during row create.
1.3.6.1.4.1.5504.5.14.1.3.1.12Unsigned32read-createcurrent
zhoneGponPortConfigTrafficManagementProfileIndex
OBJECT-TYPE
This object points to the associated Traffic Management profile. If there is no traffic control for the GEM port, set it to 0.
1.3.6.1.4.1.5504.5.14.1.3.1.13Unsigned32 (0..2147483647)read-createcurrent
zhoneGponAllocIdTable
OBJECT-TYPE
Table for management of upstream bandwidth
1.3.6.1.4.1.5504.5.14.1.4not-accessiblecurrent
zhoneGponAllocIdEntry
OBJECT-TYPE
Entry in the gpon allocId table.
1.3.6.1.4.1.5504.5.14.1.4.1not-accessiblecurrent
zhoneGponAllocIdIndex
OBJECT-TYPE
An Id number which must be unique for a given OLT.
1.3.6.1.4.1.5504.5.14.1.4.1.1Integer32 (1..2147483647)not-accessiblecurrent
zhoneGponAllocIdRowStatus
OBJECT-TYPE
Row status for the gpon alloc-id table.
1.3.6.1.4.1.5504.5.14.1.4.1.2ZhoneRowStatusread-createcurrent
zhoneGponAllocIdOnuId
OBJECT-TYPE
The onu number for this olt to which we are allocating bandwidth. Cannot be greater than number of onus for the olt. This field cannot be changed once the alloc-id has been created.
1.3.6.1.4.1.5504.5.14.1.4.1.3Integer32read-createcurrent
zhoneGponAllocIdGuaranteedBw
OBJECT-TYPE
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
1.3.6.1.4.1.5504.5.14.1.4.1.4Integer32read-createcurrent
zhoneGponAllocIdTrafficClass
OBJECT-TYPE
Whether traffic is Constant Bit Rate or Unspecified Bit Rate.
1.3.6.1.4.1.5504.5.14.1.4.1.5INTEGER {cbr(1), ubr(2)}read-createcurrent
zhoneGponAllocIdCompensated
OBJECT-TYPE
For CBR, indicates whether compensated.
1.3.6.1.4.1.5504.5.14.1.4.1.6TruthValueread-createcurrent
zhoneGponSerialNoTable
OBJECT-TYPE
Table of discovered serial numbers available for assignment to onus.
1.3.6.1.4.1.5504.5.14.1.5not-accessiblecurrent
zhoneGponSerialNoEntry
OBJECT-TYPE
Row in the Gpon onu serial number table
1.3.6.1.4.1.5504.5.14.1.5.1not-accessiblecurrent
zhoneGponSerialNoOltLgIfIndex
OBJECT-TYPE
Linegroup ifIndex of the Olt on which serial number was discovered.
1.3.6.1.4.1.5504.5.14.1.5.1.1InterfaceIndexnot-accessiblecurrent
zhoneGponSerialNoIndexId
OBJECT-TYPE
An identifying number, unique within olt, for this discovered onu serial number.
1.3.6.1.4.1.5504.5.14.1.5.1.2Unsigned32not-accessiblecurrent
zhoneGponSerialNoVendorId
OBJECT-TYPE
The 4-character vendor id portion of serial number.
1.3.6.1.4.1.5504.5.14.1.5.1.3ZhoneAdminString (SIZE(0..4))read-onlycurrent
zhoneGponSerialNoVendorSpecific
OBJECT-TYPE
Vendor specific portion of the unassigned onu serial number, a string of decimal digits.
1.3.6.1.4.1.5504.5.14.1.5.1.4ZhoneAdminString (SIZE(1..10))read-writecurrent
zhoneGponSerialNoTimeStamp
OBJECT-TYPE
Time, as ascii string, that the serial number was discovered.
1.3.6.1.4.1.5504.5.14.1.5.1.5OCTET STRING (SIZE(0..32))read-onlycurrent
zhoneGponTrapPrefix
OBJECT-IDENTITY
Place-holder object for gpon traps, which must have a final digit of 0 in OID.
1.3.6.1.4.1.5504.5.14.1.6current
zhoneGponTraps
OBJECT-IDENTITY
Traps raised by Gpon Rp.
1.3.6.1.4.1.5504.5.14.1.6.0current
zhoneGponOnuStatusTable
OBJECT-TYPE
Current status of onu as reported from Gpon driver.
1.3.6.1.4.1.5504.5.14.1.7not-accessiblecurrent
zhoneGponOnuStatusEntry
OBJECT-TYPE
Row in the zhoneGponOnuStatusTable.
1.3.6.1.4.1.5504.5.14.1.7.1not-accessiblecurrent
zhoneGponOnuStatusWord
OBJECT-TYPE
Bit-encoded current onu status from gpon driver
1.3.6.1.4.1.5504.5.14.1.7.1.1Bits {noAlarm(0), inactive(1), lossOfSignal(2), lossOfFrame(3), driftOfWindow(4), signalFail(5), signalDegrade(6), lossOfGemChanDelin(7), remoteDefect(8), transmitterFailure(9), startUpFailure(10), lossOfAck(11), dyingGasp(12), lossOfPloamSync(13), messageError(14), physEquipError(15), bit16notUsed(16), bit17notUsed(17), excessiveBipErrorsOnuDisabled(18), excessiveBipErrorsOnuNotDisabled(19), usRxPowerErrorOnuDisabled(20), usRxPowerErrorOnuNotDisabled(21), rogueOnu(22), manualOnuRebooted(23)}read-onlycurrent
zhoneGponOnuOmciState
OBJECT-TYPE
Current configuration status for ONU. 1. queued for configuration (waiting) 2. transitional state before configuration (pending) 3. in process of configuration (config) 4. unspecified error (error) 5. configuration successful (done) 6. image download in progress (download) 7. image download aborted (aborted) 8. state cannot be determined (unknown) 9. ONU is down (down) 10. no configuration has been attempted (noConfig) 11. ONU unreachable for RG configuration (rgComError) 12. Some RG commands failed, may impact service (rgServiceSetupErr) 13. OMCI configuration failed (omciFailed) 14. OMCI failed and also ONU unreachable for RG (omciErrAndRgComErr) 15. OMCI failed and also RG commands failed (omciErrAndRgServErr) 16. Some post-config commands failed (postCfgError) 17. OMCI failed and also some post-config commands failed (omciErrAndPostCfgErr)
1.3.6.1.4.1.5504.5.14.1.7.1.2INTEGER {waiting(1), pending(2), config(3), error(4), done(5), download(6), aborted(7), unknown(8), down(9), noConfig(10), rgComError(11), rgServiceSetupErr(12), omciFailed(13), omciErrAndRgComErr(14), omciErrAndRgServErr(15), postCfgError(16), omciErrAndPostCfgErr(17)}read-onlycurrent
zhoneGponOnuOpticRssi
OBJECT-TYPE
RSSI power of the SFP per ONU. The value is in tenths of dB.
1.3.6.1.4.1.5504.5.14.1.7.1.3Integer32 (-600..200)read-onlycurrent
zhoneGponOntRxPower
OBJECT-TYPE
Rx Power as reported by the ONT. The value is in tenths of dB.
1.3.6.1.4.1.5504.5.14.1.7.1.4Integer32 (-600..200)read-onlycurrent
zhoneGponOntVersion
OBJECT-TYPE
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
1.3.6.1.4.1.5504.5.14.1.7.1.5OCTET STRING (SIZE(0..14))read-onlycurrent
zhoneGponOnuDistance
OBJECT-TYPE
Distance from Olt to Ont in meters, as computed from Eqd.
1.3.6.1.4.1.5504.5.14.1.7.1.6Unsigned32read-onlycurrent
zhoneOnuOmciMEProfileTable
OBJECT-TYPE
Table containing the OMCI commands for the Managed Entities (ME) on an ONU. The following 'how to' examples demonstrate access of the object zhoneOnuOmciMEOmciCommands. How to create ME profile: 1. Determine ME profile instance <aaa> 2. Place file <filename> into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = create zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = <filename> How to update existing ME profile from a file: 1. Determine ME profile instance <aaa> 2. Place file <filename> into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = import zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = <filename> How to extract ME profile into a file: 1. Determine ME profile instance <aaa> 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = export zhoneOnuOmciMEProfileFilename.aaa = <filename> 3. The file <filename> now exists on uplink file system How to delete ME profile: 1. Determine ME profile instance <aaa> 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = destroy
1.3.6.1.4.1.5504.5.14.1.8not-accessiblecurrent
zhoneOnuOmciMEProfileEntry
OBJECT-TYPE
Row in the ME Profile table.
1.3.6.1.4.1.5504.5.14.1.8.1not-accessiblecurrent
zhoneOnuOmciMEProfileIndex
OBJECT-TYPE
A unique index for each row entry (1..n).
1.3.6.1.4.1.5504.5.14.1.8.1.1Unsigned32not-accessiblecurrent
zhoneOnuOmciMEProfileRowStatus
OBJECT-TYPE
Row status for the Me profile entry. Not really used for the configuration on the ONUs
1.3.6.1.4.1.5504.5.14.1.8.1.2INTEGER {active(1), create(2), destroy(3), export(4), import(5), append(6), revert(7)}read-createcurrent
zhoneOnuOmciMEProfileName
OBJECT-TYPE
Name given to each row entry in the ME Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the ME profiles.
1.3.6.1.4.1.5504.5.14.1.8.1.3OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciMEProfileOmciCommands
OBJECT-TYPE
Contains the set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss. This object cannot be accessed directly. See the comments section for zhoneOnuCmciMEProfileTable on how to acces this object.
1.3.6.1.4.1.5504.5.14.1.8.1.4OCTET STRING (SIZE(0..64000))read-createcurrent
zhoneOnuOmciMEProfileFileName
OBJECT-TYPE
Name of file to be loaded into profile. This object is write-only and is not preserved.
1.3.6.1.4.1.5504.5.14.1.8.1.5OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciGenericProfileTable
OBJECT-TYPE
Table containing Generic OMCI commands for an ONU. The Generic profile is 'created' from an existing ME profile. During this operation, the 'variable' defintions from the ME profile are extracted from the ME profile and placed into the Generic profile. The Generic profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciGenericOmciCommands. How to create Generic profile from ME profile: 1. Determine Generic profile instance <aaa> 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = create zhoneOnuOmciGenericProfileName.aaa = profile name zhoneOnuOmciGenericProfileMESrcProfileName = ME profile source 3. Profile is now created and the profile will not contain any variables and values. How to update existing Generic profile from a file: 1. Determine Generic profile instance <aaa> 2. Place file <filename> into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = <filename> How to extract Generic profile into a file: 1. Determine ME profile instance <aaa> 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = <filename> 3. The file <filename> now exists on uplink file system How to delete Generic profile: 1. Determine Generic profile instance <aaa> 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
1.3.6.1.4.1.5504.5.14.1.9not-accessiblecurrent
zhoneOnuOmciGenericProfileEntry
OBJECT-TYPE
Row in the OMCI Generic Profile table
1.3.6.1.4.1.5504.5.14.1.9.1not-accessiblecurrent
zhoneOnuOmciGenericProfileIndex
OBJECT-TYPE
A unique index for each row entry ( 1..n ).
1.3.6.1.4.1.5504.5.14.1.9.1.1Unsigned32not-accessiblecurrent
zhoneOnuOmciGenericProfileRowStatus
OBJECT-TYPE
Row status for the Generic profile entry. Not really used for the configuration of the ONUs
1.3.6.1.4.1.5504.5.14.1.9.1.2INTEGER {active(1), create(2), destroy(3), export(4), import(5)}read-createcurrent
zhoneOnuOmciGenericProfileName
OBJECT-TYPE
Name given to each row entry in the Generic Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the Generic profiles.
1.3.6.1.4.1.5504.5.14.1.9.1.3OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciGenericProfileOmciCommands
OBJECT-TYPE
Contains the generic set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
1.3.6.1.4.1.5504.5.14.1.9.1.4OCTET STRING (SIZE(0..15000))read-createcurrent
zhoneOnuOmciGenericProfileMESrcProfileName
OBJECT-TYPE
Name of ME profile used to create the Generic profile. The value for this object is only initialized when the profile is created.
1.3.6.1.4.1.5504.5.14.1.9.1.5OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciGenericProfileFileName
OBJECT-TYPE
Name of file to be loaded into profile. This object is write-only and is not preserved.
1.3.6.1.4.1.5504.5.14.1.9.1.6OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciSpecificProfileTable
OBJECT-TYPE
Table containing Specific OMCI commands for an ONU. The Specific profile is 'created' from existing ME and Generic profiles. During this operation, the 'variable' defintions from the ME and Generic profile are extracted from the profiles and placed into the Specific profile. The ME and Generic profile names are extracted from the ONU's Olt/Onu config profile. The Specific profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciSpecificOmciCommands. How to create Specific profile from ME and Generic profiles: 1. Determine Specific profile instance <aaa> (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciSpecificProfileRowStatus.aaa = create zhoneOnuOmciSpecificProfileFileName = <filename> 3. The profile is now created and the omciCommands contents have been placed into <filename>. The name of the ME profile used to create the Speofic profile is installed into zhoneOnuOmciSpecificProfileMESrcProfile. How to update existing Specific profile from a file: 1. Determine Specific profile instance <aaa> (from ONU's ifIndex) 2. Place file <filename> into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = <filename> How to extract Specific profile into a file: 1. Determine Specific profile instance <aaa> (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = <filename> 3. The file <filename> now exists on uplink file system How to delete Specific profile: 1. Determine Specific profile instance <aaa> (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
1.3.6.1.4.1.5504.5.14.1.10not-accessiblecurrent
zhoneOnuOmciSpecificProfileEntry
OBJECT-TYPE
Row in the OMCI Specific Profile table
1.3.6.1.4.1.5504.5.14.1.10.1not-accessiblecurrent
zhoneOnuOmciSpecificProfileIndex
OBJECT-TYPE
A unique index for each row entry. The index value corresponds to the ifIndex of the ONU which uses this profile.
1.3.6.1.4.1.5504.5.14.1.10.1.1InterfaceIndexnot-accessiblecurrent
zhoneOnuOmciSpecificProfileRowStatus
OBJECT-TYPE
Row status for the Specific Profile entry. Not really used for the configuration of the ONUs
1.3.6.1.4.1.5504.5.14.1.10.1.2INTEGER {active(1), create(2), destroy(3), export(4), import(5)}read-createcurrent
zhoneOnuOmciSpecificProfileOmciCommands
OBJECT-TYPE
Contains the Specific set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
1.3.6.1.4.1.5504.5.14.1.10.1.3OCTET STRING (SIZE(0..8000))read-createcurrent
zhoneOnuOmciSpecificProfileMESrcProfileName
OBJECT-TYPE
Name of ME profile used to create the Specific profile. The value for this object is only initialized when the profile is created.
1.3.6.1.4.1.5504.5.14.1.10.1.4OCTET STRING (SIZE(0..64))read-createcurrent
zhoneOnuOmciSpecificProfileFileName
OBJECT-TYPE
Name of file to be loaded into profile. This object is write-only and is not preserved.
1.3.6.1.4.1.5504.5.14.1.10.1.5OCTET STRING (SIZE(0..64))read-createcurrent
zhoneGponOmciOnuAlarmsTable
OBJECT-TYPE
A table of all GPON OMCI ONU alarms.
1.3.6.1.4.1.5504.5.14.1.11not-accessiblecurrent
zhoneGponOmciOnuAlarmsEntry
OBJECT-TYPE
An entry for each ONU in the zhoneGponOmciOnuAlarmsTable.
1.3.6.1.4.1.5504.5.14.1.11.1not-accessiblecurrent
zhoneGponOmciOnuAlarmsText
OBJECT-TYPE
This is a long ascii string which contains the GPON OMCI ONU alarms. Each line of text in this string has the following format: aaa,bbb,ccc,'aaaStr,'bbbStr',d\n where aaa : ME classId ( numeric decimal value ) bbb : alarm index ( numeric decimal value ) ccc : entityId ( numeric decimal value ) aaaStr : string version of ME name bbbStr : string version of alarm name d : alarm severity ( 1=critical, 2=major, 3=minor, 4=warning ) The ME classId is the standard value from the 'Managed entity identifiers' table of G984.4. The alarm index is the zero-based index (G984.4 or G983.2) within the ME class. the entityId is the physical port number on the ONT. Here is a sample: 11,0,513,'PptpEthUni','LanLos',2\n 256,1,0,'OntG','PoweringAlarm',3\n If this string has zero length then there are no active alarms. If this string has a single entry with a classId of 65535 then the alarm collection failed. WARNING! In this description, replace the sinqle quote characters with double quote characters! The Zhone scripts have problems with double quote characters!
1.3.6.1.4.1.5504.5.14.1.11.1.1OCTET STRING (SIZE(0..16000))read-onlycurrent
zhoneGponTrafficProfileTable
OBJECT-TYPE
A table of the GPON GEM Port Traffic profiles.
1.3.6.1.4.1.5504.5.14.1.12not-accessiblecurrent
zhoneGponTrafficProfileEntry
OBJECT-TYPE
Row in the zhoneGponPortTrafProfileTable.
1.3.6.1.4.1.5504.5.14.1.12.1not-accessiblecurrent
zhoneGponTrafficProfileIndex
OBJECT-TYPE
Used to index an entry in the GEM port traffic profile table
1.3.6.1.4.1.5504.5.14.1.12.1.1Unsigned32not-accessiblecurrent
zhoneGponTrafficProfileRowStatus
OBJECT-TYPE
The row status for the GEM Port Traffic profile.
1.3.6.1.4.1.5504.5.14.1.12.1.2ZhoneRowStatusread-createcurrent
zhoneGponTrafficProfileGuaranteedUpstreamBw
OBJECT-TYPE
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
1.3.6.1.4.1.5504.5.14.1.12.1.3Integer32 (0..1048576)read-createcurrent
zhoneGponTrafficProfileClass
OBJECT-TYPE
Whether traffic is Constant Bit Rate or Unspecified Bit Rate.
1.3.6.1.4.1.5504.5.14.1.12.1.4INTEGER {cbr(1), ubr(2)}read-createcurrent
zhoneGponTrafficProfileCompensated
OBJECT-TYPE
For CBR, indicates whether compensated.
1.3.6.1.4.1.5504.5.14.1.12.1.5TruthValueread-createcurrent
zhoneGponTrafficProfileShared
OBJECT-TYPE
TRUE if the GEM Port which uses this traffic descriptor shares and allocation ID with another GEM port. FALSE otherwise. When used more than once in the same ONU, the GEM ports are assigned the same alloc-id value.
1.3.6.1.4.1.5504.5.14.1.12.1.6TruthValueread-createcurrent
zhoneGponTrafficProfileDbaEnabled
OBJECT-TYPE
A flag to indicate if dynamic or static bandwidth allocation is used. The default value of DbaEnabled is false.
1.3.6.1.4.1.5504.5.14.1.12.1.7TruthValueread-createcurrent
zhoneGponTrafficProfileDbaFixedUsUbrBw
OBJECT-TYPE
Fixed UBR bandwidth will be always allocated UBR bandwidth. The min values of Fixed Ubr bandwidth can be 0 or 128kilo bits per second.Only multiples of 64 kilobits per second are allowed.
1.3.6.1.4.1.5504.5.14.1.12.1.8Unsigned32 (0..1048576)read-createcurrent
zhoneGponTrafficProfileDbaFixedUsCbrBw
OBJECT-TYPE
Fixed CBR bandwidth will be always allocated CBR bandwidth. The min value of Fixed Cbr bandwidth can be 0 or 512 kilobits per second.Only multiples of 64 kilo bits per second are allowed.
1.3.6.1.4.1.5504.5.14.1.12.1.9Unsigned32 (0..454208)read-createcurrent
zhoneGponTrafficProfileDbaAssuredUsBw
OBJECT-TYPE
DBA Assured bandwidth will be allocated when traffic demand exists. The min value of Assured bandwidth can be 0 or 256 kilobits per second. Only multiples of 64 kilo bits per second are allowed.
1.3.6.1.4.1.5504.5.14.1.12.1.10Unsigned32 (0..1048576)read-createcurrent
zhoneGponTrafficProfileMaxUsBw
OBJECT-TYPE
The Max Bandwidth value should be larger or equal to the sum of Fixed UBR, Fixed CBR and Assured.The increments should be done in the order of 64 kilobits per second.The default value of maximum bandwidth is 0.
1.3.6.1.4.1.5504.5.14.1.12.1.11Unsigned32 (0..1048576)read-createcurrent
zhoneGponTrafficProfileExtraUsBwType
OBJECT-TYPE
Extra Bandwidth = MaxBw - (Assured+FixedUbr+FixedCbr) The two Extra bandwidth types supported are : 1.nonassured 2.besteffort By default the value is nonassured.Nonassured has higher priority for getting unused bandwidth than besteffort.
1.3.6.1.4.1.5504.5.14.1.12.1.12INTEGER {nonassured(1), besteffort(2)}read-createcurrent
zhoneGponPortStatusTable
OBJECT-TYPE
Current status of GEM port as reported from Gpon driver.
1.3.6.1.4.1.5504.5.14.1.13not-accessiblecurrent
zhoneGponPortStatusEntry
OBJECT-TYPE
Row in the zhoneGponPortStatusTable.
1.3.6.1.4.1.5504.5.14.1.13.1not-accessiblecurrent
zhoneGponPortStatusAllocId
OBJECT-TYPE
The current dynamic alloc-id value for the GEM port.
1.3.6.1.4.1.5504.5.14.1.13.1.1Unsigned32read-onlycurrent
zhoneGponPortStatusDbaStatus
OBJECT-TYPE
The current DBA status for this GEM port. DBA status reporting is on a per-ONU basis. All GEM ports on the ONU will report the same value. Possible values: sr - DBA type is SR and there is no error nsr - DBA type is NSR and there is no error nsrError - DBA type is NSR and there is an error or the ONU does not support NSR notEnabled - DBA has been disabled notAvailable - cannot communicate with ONU notAdded - ONU is not added to the OLT error - internal error prevents data collection
1.3.6.1.4.1.5504.5.14.1.13.1.2INTEGER {sr(1), nsr(2), nsrError(3), notEnabled(4), notAvailable(5), notAdded(6), error(7)}read-onlycurrent
zhoneGponOmciStatsCurrentTable
OBJECT-TYPE
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
1.3.6.1.4.1.5504.5.14.1.14not-accessiblecurrent
zhoneGponOmciStatsCurrentEntry
OBJECT-TYPE
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
1.3.6.1.4.1.5504.5.14.1.14.1not-accessiblecurrent
zhoneGponOmciStatsCurrentMEId
OBJECT-TYPE
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
1.3.6.1.4.1.5504.5.14.1.14.1.1Unsigned32not-accessiblecurrent
zhoneGponOmciStatsCurrentLogicalPort
OBJECT-TYPE
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
1.3.6.1.4.1.5504.5.14.1.14.1.2Unsigned32not-accessiblecurrent
zhoneGponOmciStatsCurrentText
OBJECT-TYPE
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
1.3.6.1.4.1.5504.5.14.1.14.1.3OCTET STRING (SIZE(0..256))read-onlycurrent
zhoneGponOmciStatsPreviousTable
OBJECT-TYPE
Table of previous-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
1.3.6.1.4.1.5504.5.14.1.15not-accessiblecurrent
zhoneGponOmciStatsPreviousEntry
OBJECT-TYPE
Row in zhoneGponOmciStatsPreviousTable. Each row retrieves counters for the last completed 15-minute interval for one managed entity on one logical port of one ONT.
1.3.6.1.4.1.5504.5.14.1.15.1not-accessiblecurrent
zhoneGponOmciStatsPreviousMEId
OBJECT-TYPE
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
1.3.6.1.4.1.5504.5.14.1.15.1.1Unsigned32not-accessiblecurrent
zhoneGponOmciStatsPreviousLogicalPort
OBJECT-TYPE
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
1.3.6.1.4.1.5504.5.14.1.15.1.2Unsigned32not-accessiblecurrent
zhoneGponOmciStatsPreviousText
OBJECT-TYPE
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
1.3.6.1.4.1.5504.5.14.1.15.1.3OCTET STRING (SIZE(0..256))read-onlycurrent
zhoneGponOmciStatusTable
OBJECT-TYPE
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
1.3.6.1.4.1.5504.5.14.1.16not-accessiblecurrent
zhoneGponOmciStatusEntry
OBJECT-TYPE
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
1.3.6.1.4.1.5504.5.14.1.16.1not-accessiblecurrent
zhoneGponOmciStatusMEId
OBJECT-TYPE
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
1.3.6.1.4.1.5504.5.14.1.16.1.1Unsigned32not-accessiblecurrent
zhoneGponOmciStatusLogicalPort
OBJECT-TYPE
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
1.3.6.1.4.1.5504.5.14.1.16.1.2Unsigned32not-accessiblecurrent
zhoneGponOmciStatusText
OBJECT-TYPE
Blob of status information returned. Format is: PhysPort,attrId1,attrName1,attrNumValue1,attrStrValue1... attrIdn,attrNamen,attrNumValuen,attrStrValuen where PhysPort - physical port ID value attrIdn = index number (0-15) of the attribute within the the ME (ascii decimal) attrNamen = name of the attribute (returned by OCS) attrNumValuen = value of the attribute (ascii decimal) attrStrValuen = interpreted value ( 'up', 'down', etc ) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
1.3.6.1.4.1.5504.5.14.1.16.1.3OCTET STRING (SIZE(0..512))read-onlycurrent
zhoneGponOmciOnuRebootTable
OBJECT-TYPE
Table of objects used to reboot an ONU via the OMCI.
1.3.6.1.4.1.5504.5.14.1.17not-accessiblecurrent
zhoneGponOmciOnuRebootEntry
OBJECT-TYPE
A single entry in the table
1.3.6.1.4.1.5504.5.14.1.17.1not-accessiblecurrent
zhoneGponOmciOnuReboot
OBJECT-TYPE
Set this object to 'reboot to reboot an ONU. The reboot command is sent to the ONU over the OMCI. Successful transmission of the reboot command to the ONU does no guarantee the ONU will reboot. The ONU may be in a fatal lockup which prevents the processing of the reboot command.
1.3.6.1.4.1.5504.5.14.1.17.1.1INTEGER {none(0), reboot(1)}read-createcurrent
zhoneGponOmciOnuPortAdminTable
OBJECT-TYPE
Table of objects used to configure the admin state of a physical port on an ONU.
1.3.6.1.4.1.5504.5.14.1.18not-accessiblecurrent
zhoneGponOmciOnuPortAdminEntry
OBJECT-TYPE
A single entry in the table
1.3.6.1.4.1.5504.5.14.1.18.1not-accessiblecurrent
zhoneGponOmciOnuPortAdminMEId
OBJECT-TYPE
This is the ID of the managed entity in the ITU G984.4 standard.
1.3.6.1.4.1.5504.5.14.1.18.1.1Unsigned32not-accessiblecurrent
zhoneGponOmciOnuPortAdminLogicalPort
OBJECT-TYPE
This specifies which entity on the ONT we want. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
1.3.6.1.4.1.5504.5.14.1.18.1.2Unsigned32not-accessiblecurrent
zhoneGponOmciOnuPortAdminState
OBJECT-TYPE
This object is used to place an ONU physical port in a DOWN or UP state. This state is a configuration parameter and is preserved.
1.3.6.1.4.1.5504.5.14.1.18.1.3INTEGER {none(0), up(1), down(2)}read-createcurrent
zhoneGponOmciOnuPortAdminAutoDetect
OBJECT-TYPE
This object is used to set the auto detection rate of an ONU physical port.This state is a configuration parameter and is preserved.
1.3.6.1.4.1.5504.5.14.1.18.1.4INTEGER {none(0), auto(1), tenFull(2), hundredFull(3), thousandFull(4), tenAuto(5), tenHalf(6), hundredHalf(7), thousandHalf(8), thousandAuto(9), autoFull(10), autoHalf(11), hundredAuto(12)}read-createcurrent
zhoneGponOmciOnuImageUpgradeTable
OBJECT-TYPE
This table is used to perform ONU software upgrades. There is one table entry for each ONU. Each ONU is addressed by it's ifIndex.
1.3.6.1.4.1.5504.5.14.1.19not-accessiblecurrent
zhoneGponOmciOnuImageUpgradeEntry
OBJECT-TYPE
An entry for one ONU.
1.3.6.1.4.1.5504.5.14.1.19.1not-accessiblecurrent
zhoneGponOmciOnuImageUpgradeAction
OBJECT-TYPE
Which software upgrade action to perform.
1.3.6.1.4.1.5504.5.14.1.19.1.1INTEGER {none(0), download(1), activate(2), commit(3), downloadActivate(4), downloadActivateCommit(5), abortDownload(6), activateCommit(7)}read-createcurrent
zhoneOnuOmciImageUpgradeFilename
OBJECT-TYPE
Name of file to be loaded downloaded to ONU. Required on download actions.
1.3.6.1.4.1.5504.5.14.1.19.1.2OCTET STRING (SIZE(0..64))read-createcurrent
zhoneGponOmciOnuImageUpgradePartition
OBJECT-TYPE
Optional on all actions. Indicates which partition or 'none'in which case default is to use inactive partition for download or activate action, or to the uncommitted partion for commit action. On a read, returns the partition used for current or latest upgrade.
1.3.6.1.4.1.5504.5.14.1.19.1.3INTEGER {none(0), partitionNumber0(1), partitionNumber1(2)}read-createcurrent
zhoneOnuOmciImageUpgradeImageVersionPartition0
OBJECT-TYPE
Version information for s/w image loaded into partition 0.
1.3.6.1.4.1.5504.5.14.1.19.1.4OCTET STRING (SIZE(0..64))read-onlycurrent
zhoneOnuOmciImageUpgradeImageVersionPartition1
OBJECT-TYPE
Version information for s/w image loaded into partition 1.
1.3.6.1.4.1.5504.5.14.1.19.1.5OCTET STRING (SIZE(0..64))read-onlycurrent
zhoneOnuOmciImageUpgradeIsCommittedPartition0
OBJECT-TYPE
Current commit status for partition 0.
1.3.6.1.4.1.5504.5.14.1.19.1.6INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeIsCommittedPartition1
OBJECT-TYPE
Current commit status for partition 1.
1.3.6.1.4.1.5504.5.14.1.19.1.7INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeIsActivatedPartition0
OBJECT-TYPE
Current activated status for partition 0.
1.3.6.1.4.1.5504.5.14.1.19.1.8INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeIsActivatedPartition1
OBJECT-TYPE
Current activated status for partition 1.
1.3.6.1.4.1.5504.5.14.1.19.1.9INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeIsValidPartition0
OBJECT-TYPE
Current valid status for partition 0.
1.3.6.1.4.1.5504.5.14.1.19.1.10INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeIsValidPartition1
OBJECT-TYPE
Current valid status for partition 0.
1.3.6.1.4.1.5504.5.14.1.19.1.11INTEGER {none(0), true(1), false(2)}read-onlycurrent
zhoneOnuOmciImageUpgradeDownloadStatus
OBJECT-TYPE
Current s/w image download status.
1.3.6.1.4.1.5504.5.14.1.19.1.12OnuUpgradeStateread-onlycurrent
zhoneGponOmciOnuImageUpgradeModel
OBJECT-TYPE
Model id read from this onu.
1.3.6.1.4.1.5504.5.14.1.19.1.13OCTET STRING (SIZE(0..20))read-onlycurrent
zhoneGponOmciOnuImageUpgradeStartTime
OBJECT-TYPE
Start time, as ascii string, of most recent upgrade.
1.3.6.1.4.1.5504.5.14.1.19.1.14OCTET STRING (SIZE(0..32))read-onlycurrent
zhoneGponOmciOnuImageUpgradeWillBeActivated
OBJECT-TYPE
If true, the downloaded image will be activated when download completes.
1.3.6.1.4.1.5504.5.14.1.19.1.15TruthValueread-onlycurrent
zhoneGponOmciOnuImageUpgradeWillBeCommitted
OBJECT-TYPE
If true, this image will be committed on successful activation.
1.3.6.1.4.1.5504.5.14.1.19.1.16TruthValueread-onlycurrent
zhoneGponOmciOnuImageUpgradeType
OBJECT-TYPE
Indicates the reason for the upgrade.
1.3.6.1.4.1.5504.5.14.1.19.1.17INTEGER {none(0), manual(1), auto(2), bulk(3)}read-onlycurrent
zhoneGponOmciOnuImageDownloadProgressPercentage
OBJECT-TYPE
Image download progress. This object is only valid during image download.
1.3.6.1.4.1.5504.5.14.1.19.1.18INTEGER (0..100)read-onlycurrent
zhoneGponOmciOnuImageUpgradeMethod
OBJECT-TYPE
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default).
1.3.6.1.4.1.5504.5.14.1.19.1.19INTEGER {omci(1), tftp(2)}read-onlycurrent
zhoneGponOltStatusTable
OBJECT-TYPE
Current Status of OLT as reported from the Gpon Driver.
1.3.6.1.4.1.5504.5.14.1.20not-accessiblecurrent
zhoneGponOltStatusEntry
OBJECT-TYPE
Row in the zhoneGponOltStatusTable.
1.3.6.1.4.1.5504.5.14.1.20.1not-accessiblecurrent
zhoneGponOltOpticTemperature
OBJECT-TYPE
Internally measured Tranceiver Temperature of the OLT in Celcius.
1.3.6.1.4.1.5504.5.14.1.20.1.1Integer32 (-128..128)read-onlycurrent
zhoneGponOltOpticVoltage
OBJECT-TYPE
Internally measured Tranceiver Supply Voltage of the OLT in Volts. The measured value will be in the order of hundredths of Volts.
1.3.6.1.4.1.5504.5.14.1.20.1.2Unsigned32 (0..655)read-onlycurrent
zhoneGponOltOpticTxBiasCurrent
OBJECT-TYPE
Measured Tx Bias current per OLT in milli Amperes.
1.3.6.1.4.1.5504.5.14.1.20.1.3Unsigned32 (0..131)read-onlycurrent
zhoneGponOltOpticTxPower
OBJECT-TYPE
Measured Tx Output Power of the OLT in dB. The measured value will be in tenths of dB.
1.3.6.1.4.1.5504.5.14.1.20.1.4Integer32 (-600..200)read-onlycurrent
zhoneGponOltOpticStatus
OBJECT-TYPE
When the End Of Life(EOL) Alarm bit is set an alarm will be raised. Alarm is set at about 150% of original current.Alarm will be level Major. It will be cleared when the SFP is replaced, or when the Alarm bit is cleared. Warning indication will be provided when user asks for status. Warning is set when EOL is at about 130% original current.
1.3.6.1.4.1.5504.5.14.1.20.1.5INTEGER {ok(1), warning(2), alarm(4), sfpnotpresent(8), oltactive(16)}read-onlycurrent
zhoneGponOltOpticAlarms
OBJECT-TYPE
Bitmap of alarm conditions present, as reported from the SFP.
1.3.6.1.4.1.5504.5.14.1.20.1.6Bits {tempHigh(0), tempLow(1), vccHigh(2), vccLow(3), txBiasHigh(4), txBiasLow(5), txPwrHigh(6), txPwrLow(7), rxPwrHigh(8), rxPwrLow(9)}read-onlycurrent
zhoneGponOltStatusWord
OBJECT-TYPE
The bit-coded OLT status word.
1.3.6.1.4.1.5504.5.14.1.20.1.7Bits {noAlarm(0), notused1(1), notused2(2), notused3(3), notused4(4), notused5(5), lossOfSignal(6), notused7(7), notused8(8), outOfService(9), rogueOnu(10), rogueOnuRssi(11), sgmiiGeLinkDown(12)}read-onlycurrent
zhoneGponOltConfiguredOnuCount
OBJECT-TYPE
Count of the ONUs on this OLT where onu-added = TRUE.
1.3.6.1.4.1.5504.5.14.1.20.1.8Unsigned32read-onlycurrent
zhoneGponOltActiveOnuCount
OBJECT-TYPE
Number of ONUs on this OLT currently in operational state UP.
1.3.6.1.4.1.5504.5.14.1.20.1.9Unsigned32read-onlycurrent
zhoneGponOltDbaStatusTable
OBJECT-TYPE
Current status of OLT DBA as reported from CAC.
1.3.6.1.4.1.5504.5.14.1.21not-accessiblecurrent
zhoneGponOltDbaStatusEntry
OBJECT-TYPE
Row in the zhoneGponOltDbaStatusTable.
1.3.6.1.4.1.5504.5.14.1.21.1not-accessiblecurrent
zhoneGponOltDbaTotalAvailableBw
OBJECT-TYPE
The Total Available DBA Bandwidth per OLT.The unit is Kilobits( 1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.1Unsigned32read-onlycurrent
zhoneGponOltDbaTotalAvailableCompensatedCbrBw
OBJECT-TYPE
The Total Available DBA Compensated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.2Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedUbrBw
OBJECT-TYPE
The Total Available DBA Allocated UBR bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.3Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedCbrBw
OBJECT-TYPE
The Total Available DBA Allocated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.4Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedCompensatedCbrBw
OBJECT-TYPE
The Total Available DBA Allocated CBR Compensated bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.5Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedAssuredBw
OBJECT-TYPE
The Total Available DBA Allocated Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.6Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedNonAssuredBw
OBJECT-TYPE
The Total Available DBA Allocated Non Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.7Unsigned32read-onlycurrent
zhoneGponOltDbaAllocatedBestEffortBw
OBJECT-TYPE
The Total Available DBA Allocated Best Effort bandwidth per OLT. The unit is Kilobits(1000 bits).
1.3.6.1.4.1.5504.5.14.1.21.1.8Unsigned32read-onlycurrent
zhoneGponOltDbaMaxAllocIds
OBJECT-TYPE
Maximum number of alloc-Ids supported by this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.9Unsigned32read-onlycurrent
zhoneGponOltDbaAvailAllocIds
OBJECT-TYPE
Total number of available alloc-Ids for this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.10Unsigned32read-onlycurrent
zhoneGponOltDbaUsedAllocIds
OBJECT-TYPE
Total number of alloc-Ids in use for this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.11Unsigned32read-onlycurrent
zhoneGponOltDbaMaxDbaAllocIds
OBJECT-TYPE
Maximum number of DBA alloc-Ids supported by this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.12Unsigned32read-onlycurrent
zhoneGponOltDbaAvailDbaAllocIds
OBJECT-TYPE
Total number of available DBA alloc-Ids for this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.13Unsigned32read-onlycurrent
zhoneGponOltDbaUsedDbaAllocIds
OBJECT-TYPE
Total number of DBA alloc-Ids in use for this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.14Unsigned32read-onlycurrent
zhoneGponOltDbaTotalOltGemPorts
OBJECT-TYPE
Total number GEM Ports currently on this OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.15Unsigned32read-onlycurrent
zhoneGponOltDbaLastCacRc
OBJECT-TYPE
This object contains the result code of the last GPON CAC request for the OLT.
1.3.6.1.4.1.5504.5.14.1.21.1.16GponCacRcread-onlycurrent
zhoneGponUpgradeByStateTable
OBJECT-TYPE
Information about onu upgrade.
1.3.6.1.4.1.5504.5.14.1.22not-accessiblecurrent
zhoneGponUpgradeByStateEntry
OBJECT-TYPE
Row in onu upgrade table.
1.3.6.1.4.1.5504.5.14.1.22.1not-accessiblecurrent
zhoneGponUpgradeOlt
OBJECT-TYPE
Olt number on the card.
1.3.6.1.4.1.5504.5.14.1.22.1.1Integer32 (1..32)not-accessiblecurrent
zhoneGponUpgradeOnu
OBJECT-TYPE
Onu number within olt.
1.3.6.1.4.1.5504.5.14.1.22.1.2Integer32 (1..128)not-accessiblecurrent
zhoneGponUpgradeModel
OBJECT-TYPE
Model ID returned from this Onu.
1.3.6.1.4.1.5504.5.14.1.22.1.3OCTET STRING (SIZE(0..20))read-onlycurrent
zhoneGponUpgradeStartTime
OBJECT-TYPE
Last upgrade start time, as ascii string
1.3.6.1.4.1.5504.5.14.1.22.1.4OCTET STRING (SIZE(0..32))read-onlycurrent
zhoneGponUpgradeIfIndex
OBJECT-TYPE
Onu ifIndex
1.3.6.1.4.1.5504.5.14.1.22.1.5InterfaceIndexread-onlycurrent
zhoneGponUpgradeByStateOnuState
OBJECT-TYPE
The actual upgrade state of the onu.
1.3.6.1.4.1.5504.5.14.1.22.1.6OnuUpgradeStateread-onlycurrent
zhoneGponUpgradeByStateWillBeActivated
OBJECT-TYPE
If true, the image will be activated if download is successful.
1.3.6.1.4.1.5504.5.14.1.22.1.7TruthValueread-onlycurrent
zhoneGponUpgradeByStateWillBeCommitted
OBJECT-TYPE
If true, image will be committed after successful activation.
1.3.6.1.4.1.5504.5.14.1.22.1.8TruthValueread-onlycurrent
zhoneGponUpgradeByStateUpgradeType
OBJECT-TYPE
Indicates the reason for the upgrade.
1.3.6.1.4.1.5504.5.14.1.22.1.9INTEGER {none(0), manual(1), auto(2), bulk(3)}read-onlycurrent
zhoneGponUpgradeByStatePartition
OBJECT-TYPE
If upgrade has been requested, this is the image partition of the latest upgrade.
1.3.6.1.4.1.5504.5.14.1.22.1.10INTEGER {none(0), partitionNumber0(1), partitionNumber1(2)}read-onlycurrent
zhoneGponUpgradeProgressPercentage
OBJECT-TYPE
Image download progress. This object is only valid during image download.
1.3.6.1.4.1.5504.5.14.1.22.1.11INTEGER (0..100)read-onlycurrent
zhoneGponUpgradeByStateMethod
OBJECT-TYPE
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default).
1.3.6.1.4.1.5504.5.14.1.22.1.12INTEGER {omci(1), tftp(2)}read-onlycurrent
zhoneGponCmd
OBJECT-IDENTITY
1.3.6.1.4.1.5504.5.14.1.23
zhoneGponCmdOperation
OBJECT-TYPE
GPON Command operation. This object must be supplied with each operation.
1.3.6.1.4.1.5504.5.14.1.23.1INTEGER {onuApply(1), onuResync(2), onuReboot(3), onuSet2default(4), onuEnableAutoCfg(5), onuDisableAutoCfg(6)}read-writecurrent
zhoneGponCmdFilterMask
OBJECT-TYPE
GPON Command operation filter. This object must be supplied with each operation.
1.3.6.1.4.1.5504.5.14.1.23.2Bits {filterShelf(0), filterSlot(1), filterOlt(2), filterOnu(3)}read-writecurrent
zhoneGponCmdShelf
OBJECT-TYPE
GPON command 'SHELF' filter value. This parameter is for future use and is currently not supported.
1.3.6.1.4.1.5504.5.14.1.23.3Unsigned32 (1)read-writecurrent
zhoneGponCmdSlot
OBJECT-TYPE
GPON command 'SLOT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
1.3.6.1.4.1.5504.5.14.1.23.4Unsigned32 (1..32)read-writecurrent
zhoneGponCmdOlt
OBJECT-TYPE
GPON command 'OLT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
1.3.6.1.4.1.5504.5.14.1.23.5Unsigned32read-writecurrent
zhoneGponCmdOnu
OBJECT-TYPE
GPON command 'ONU' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
1.3.6.1.4.1.5504.5.14.1.23.6Unsigned32read-writecurrent
zhoneGponOltStatisticsTable
OBJECT-TYPE
Per OLT statistics gathered from Broadlight device.
1.3.6.1.4.1.5504.5.14.1.24not-accessiblecurrent
zhoneGponOltStatisticsEntry
OBJECT-TYPE
Per OLT statistics gathered from Broadlight device.
1.3.6.1.4.1.5504.5.14.1.24.1not-accessiblecurrent
zhoneGponOltStatisticsUpstreamValidGemFrames
OBJECT-TYPE
UpstreamValidGemFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.1Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamDiscardedFrames
OBJECT-TYPE
UpstreamDiscardedFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.2Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamGemFrames
OBJECT-TYPE
UpstreamGemFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.3Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamOmciFrames
OBJECT-TYPE
UpstreamOmciFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.4Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamPloamFrames
OBJECT-TYPE
UpstreamPloamFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.5Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamIdlePloamFrames
OBJECT-TYPE
UpstreamIdlePloamFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.6Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamValidGemFrames
OBJECT-TYPE
DownstreamValidGemFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.7Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamDiscardedFrames
OBJECT-TYPE
DownstreamDiscardedFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.8Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamGemFrames
OBJECT-TYPE
DownstreamGemFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.9Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamOmciFrames
OBJECT-TYPE
DownstreamOmciFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.10Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamPloamFrames
OBJECT-TYPE
DownstreamPloamFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.11Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamIdlePloamFrames
OBJECT-TYPE
DownstreamIdlePloamFrames counter.
1.3.6.1.4.1.5504.5.14.1.24.1.12Counter64read-onlydeprecated
zhoneGponOltStatisticsDownstreamPonValidEthernetPkts
OBJECT-TYPE
DownstreamPonValidEthernetPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.13Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamPonCpuPkts
OBJECT-TYPE
DownstreamPonCpuPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.14Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTxBytes
OBJECT-TYPE
DownstreamTxBytes counter.
1.3.6.1.4.1.5504.5.14.1.24.1.15Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamPonValidPkts
OBJECT-TYPE
Description.
1.3.6.1.4.1.5504.5.14.1.24.1.16Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamPonValidNotIdlePloams
OBJECT-TYPE
UpstreamPonValidNotIdlePloams counter.
1.3.6.1.4.1.5504.5.14.1.24.1.17Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamPonErrorPloams
OBJECT-TYPE
UpstreamPonErrorPloams counter.
1.3.6.1.4.1.5504.5.14.1.24.1.18Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamPonInvalidPkts
OBJECT-TYPE
UpstreamPonInvalidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.19Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamDroppedPktsInactivePorts
OBJECT-TYPE
UpstreamDroppedPktsInactivePorts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.20Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamDroppedPloamsFifoFull
OBJECT-TYPE
UpstreamDroppedPloamsFifoFull counter.
1.3.6.1.4.1.5504.5.14.1.24.1.21Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmValidPkts
OBJECT-TYPE
DownstreamTmValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.22Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmCrcPkts
OBJECT-TYPE
DownstreamTmCrcPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.23Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmDroppedCpuPkts
OBJECT-TYPE
DownstreamTmDroppedCpuPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.24Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmMacLookupMiss
OBJECT-TYPE
DownstreamTmMacLookupMiss counter.
1.3.6.1.4.1.5504.5.14.1.24.1.25Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmPktsForwardedFromHmToPon
OBJECT-TYPE
DownstreamTmPktsForwardedFromHmToPon counter.
1.3.6.1.4.1.5504.5.14.1.24.1.26Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmPktsDroppedGemPidNotEnabled
OBJECT-TYPE
DownstreamTmPktsDroppedGemPidNotEnabled counter.
1.3.6.1.4.1.5504.5.14.1.24.1.27Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ0ValidPkts
OBJECT-TYPE
DownstreamTmQ0ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.28Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ0DroppedPkts
OBJECT-TYPE
DownstreamTmQ0DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.29Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ1ValidPkts
OBJECT-TYPE
DownstreamTmQ1ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.30Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ1DroppedPkts
OBJECT-TYPE
DownstreamTmQ1DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.31Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ2ValidPkts
OBJECT-TYPE
DownstreamTmQ2ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.32Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ2DroppedPkts
OBJECT-TYPE
DownstreamTmQ2DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.33Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ3ValidPkts
OBJECT-TYPE
DownstreamTmQ3ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.34Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ3DroppedPkts
OBJECT-TYPE
DownstreamTmQ3DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.35Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ4ValidPkts
OBJECT-TYPE
DownstreamTmQ4ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.36Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ4DroppedPkts
OBJECT-TYPE
DownstreamTmQ4DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.37Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ5ValidPkts
OBJECT-TYPE
DownstreamTmQ5ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.38Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ5DroppedPkts
OBJECT-TYPE
DownstreamTmQ5DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.39Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ6ValidPkts
OBJECT-TYPE
DownstreamTmQ6ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.40Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ6DroppedPkts
OBJECT-TYPE
DownstreamTmQ6DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.41Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ7ValidPkts
OBJECT-TYPE
DownstreamTmQ7ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.42Counter64read-onlycurrent
zhoneGponOltStatisticsDownstreamTmQ7DroppedPkts
OBJECT-TYPE
DownstreamTmQ7DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.43Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmDroppedCpuPkts
OBJECT-TYPE
UpstreamTmDroppedCpuPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.44Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmDroppedPktsCrcError
OBJECT-TYPE
UpstreamTmDroppedPktsCrcError counter.
1.3.6.1.4.1.5504.5.14.1.24.1.45Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmDroppedPktsSecurity
OBJECT-TYPE
UpstreamTmDroppedPktsSecurity counter.
1.3.6.1.4.1.5504.5.14.1.24.1.46Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmLearnFailures
OBJECT-TYPE
UpstreamTmLearnFailures counter.
1.3.6.1.4.1.5504.5.14.1.24.1.47Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ0ValidPkts
OBJECT-TYPE
UpstreamTmQ0ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.48Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ0DroppedPkts
OBJECT-TYPE
UpstreamTmQ0DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.49Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ1ValidPkts
OBJECT-TYPE
UpstreamTmQ1ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.50Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ1DroppedPkts
OBJECT-TYPE
UpstreamTmQ1DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.51Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ2ValidPkts
OBJECT-TYPE
UpstreamTmQ2ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.52Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ2DroppedPkts
OBJECT-TYPE
UpstreamTmQ2DroppedPkts
1.3.6.1.4.1.5504.5.14.1.24.1.53Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ3ValidPkts
OBJECT-TYPE
UpstreamTmQ3ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.54Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ3DroppedPkts
OBJECT-TYPE
UpstreamTmQ3DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.55Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ4ValidPkts
OBJECT-TYPE
UpstreamTmQ4ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.56Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ4DroppedPkts
OBJECT-TYPE
UpstreamTmQ4DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.57Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ5ValidPkts
OBJECT-TYPE
UpstreamTmQ5ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.58Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ5DroppedPkts
OBJECT-TYPE
UpstreamTmQ5DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.59Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ6ValidPkts
OBJECT-TYPE
UpstreamTmQ6ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.60Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ6DroppedPkts
OBJECT-TYPE
UpstreamTmQ6DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.61Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ7ValidPkts
OBJECT-TYPE
UpstreamTmQ7ValidPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.62Counter64read-onlycurrent
zhoneGponOltStatisticsUpstreamTmQ7DroppedPkts
OBJECT-TYPE
UpstreamTmQ7DroppedPkts counter.
1.3.6.1.4.1.5504.5.14.1.24.1.63Counter64read-onlycurrent
zhoneGponOltStatisticsClearStats
OBJECT-TYPE
Clear all statistics for the selected interface.
1.3.6.1.4.1.5504.5.14.1.24.1.64TruthValueread-writecurrent
zhoneGponUpstreamOntStatisticsTable
OBJECT-TYPE
Per ONT Upstream Statistics provided by Broadlight.
1.3.6.1.4.1.5504.5.14.1.25not-accessiblecurrent
zhoneGponUpstreamOntStatisticsEntry
OBJECT-TYPE
Per ONT Upstream Statistics provided by Broadlight.
1.3.6.1.4.1.5504.5.14.1.25.1not-accessiblecurrent
zhoneGponUpstreamOntStatisticsUpstreamBipErrors
OBJECT-TYPE
UpstreamOntStatisticsUpstreamBipErrors counter.
1.3.6.1.4.1.5504.5.14.1.25.1.1Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsFecCorrectedBytes
OBJECT-TYPE
UpstreamOntStatisticsFecCorrectedBytes counter.
1.3.6.1.4.1.5504.5.14.1.25.1.2Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsFecCorrectedCodewords
OBJECT-TYPE
UpstreamOntStatisticsFecCorrectedCodewords counter.
1.3.6.1.4.1.5504.5.14.1.25.1.3Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsFecUncorrectedCodewords
OBJECT-TYPE
UpstreamOntStatisticsFecUncorrectedCodewords counter.
1.3.6.1.4.1.5504.5.14.1.25.1.4Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsTotalRxCodewords
OBJECT-TYPE
UpstreamOntStatisticsTotalRxCodewords counter.
1.3.6.1.4.1.5504.5.14.1.25.1.5Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsUnreceivedBursts
OBJECT-TYPE
UpstreamOntStatisticsUnreceivedBursts counter.
1.3.6.1.4.1.5504.5.14.1.25.1.6Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsBipErrors
OBJECT-TYPE
UpstreamOntStatisticsBipErrors counter.
1.3.6.1.4.1.5504.5.14.1.25.1.7Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsRemoteBipErrors
OBJECT-TYPE
UpstreamOntStatisticsRemoteBipErrors counter.
1.3.6.1.4.1.5504.5.14.1.25.1.8Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsDriftOfWindowIndications
OBJECT-TYPE
UpstreamOntStatisticsDriftOfWindowIndications counter.
1.3.6.1.4.1.5504.5.14.1.25.1.9Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsMessageErrorMessage
OBJECT-TYPE
UpstreamOntStatisticsMessageErrorMessage counter.
1.3.6.1.4.1.5504.5.14.1.25.1.10Counter64read-onlycurrent
zhoneGponUpstreamOntStatisticsClearStats
OBJECT-TYPE
Clear all statistics for the selected interface.
1.3.6.1.4.1.5504.5.14.1.25.1.11TruthValueread-writecurrent

Notifications

NameOIDStatus
zhoneGponSerialNumberFound
NOTIFICATION-TYPE
Notification that an ONU serial number has been discovered.
1.3.6.1.4.1.5504.5.14.1.6.0.1current
zhoneGponSerialNumberLost
NOTIFICATION-TYPE
Notification that a previously discovered ONU serial number is no longer available.
1.3.6.1.4.1.5504.5.14.1.6.0.2current
zhoneGponOnuLineStatusChange
NOTIFICATION-TYPE
Description.
1.3.6.1.4.1.5504.5.14.1.6.0.3current
zhoneGponOmciOnuAlarmsTrap
NOTIFICATION-TYPE
Current active alarms for an ONU entity. Alarms contained in the trap bindings will be for only one specific entity. If an entity alarm is not contained in the trap bindings then the alarm is either not active, not enabled, or not supported. If there are no alarms for the entity, then there will only be one alarm in the trap bindings and that alarm will have a value of zero and the alarm string will be 'None'.
1.3.6.1.4.1.5504.5.14.1.6.0.4current
zhoneGponOmciOnuDownloadStatusChange
NOTIFICATION-TYPE
Trap will be raised for Image Download status changes.
1.3.6.1.4.1.5504.5.14.1.6.0.5current
zhoneGponOltOpticsAlarmsTrap
NOTIFICATION-TYPE
Raised when SFP reports optics alarms condition for an SFP.
1.3.6.1.4.1.5504.5.14.1.6.0.6current
zhoneGponOnuError
NOTIFICATION-TYPE
One of the ONU error conditions is present for the specified ONU. Report zhoneGponOnuStatusWord to indicate which error has occurred.
1.3.6.1.4.1.5504.5.14.1.6.0.7current
zhoneGponRogueOnuTrap
NOTIFICATION-TYPE
A rogue ONU has been detected on this OLT by the background process
1.3.6.1.4.1.5504.5.14.1.6.0.8current
zhoneGponRssiRogueOnuTrap
NOTIFICATION-TYPE
Rogue ONU has been detected by RSSI process on this OLT.
1.3.6.1.4.1.5504.5.14.1.6.0.9current
zhoneGponOltStatusWordTrap
NOTIFICATION-TYPE
Change in one of the gpol olt status word bits has been detected.
1.3.6.1.4.1.5504.5.14.1.6.0.10current
zhoneGponOnuAutoAssign
NOTIFICATION-TYPE
Notification that an ONU ID has been auto assigned.
1.3.6.1.4.1.5504.5.14.1.6.0.11current

Conformance

NameOIDStatus
zhoneGponOltConfigGroup
OBJECT-GROUP
GPON OLT Config group
1.3.6.1.4.1.5504.9.1.10current
zhoneGponOnuConfigGroup
OBJECT-GROUP
GPON ONU Config group
1.3.6.1.4.1.5504.9.1.11current
zhoneGponPortConfigGroup
OBJECT-GROUP
GPON Port Config group
1.3.6.1.4.1.5504.9.1.12current
zhoneGponAllocIdGroup
OBJECT-GROUP
GPON Allocation ID group
1.3.6.1.4.1.5504.9.1.13current
zhoneGponSerialNoGroup
OBJECT-GROUP
GPON Serial Number group
1.3.6.1.4.1.5504.9.1.14current
zhoneGponOnuStatusGroup
OBJECT-GROUP
GPON ONU Status group
1.3.6.1.4.1.5504.9.1.15current
zhoneOnuOmciMeProfileGroup
OBJECT-GROUP
GPON OMCI ONU ME Profile group
1.3.6.1.4.1.5504.9.1.16current
zhoneOnuOmciGenericProfileGroup
OBJECT-GROUP
GPON OMCI ONU Generic Profile group
1.3.6.1.4.1.5504.9.1.17current
zhoneOnuOmciSpecificProfileGroup
OBJECT-GROUP
GPON OMCI ONU Specific Profile group
1.3.6.1.4.1.5504.9.1.18current
zhoneGponOmciOnuAlarmsGroup
OBJECT-GROUP
GPON OMCI ONU Alarms group
1.3.6.1.4.1.5504.9.1.19current
zhoneGponTrapGroup
NOTIFICATION-GROUP
Gpon Trap objects.
1.3.6.1.4.1.5504.9.1.20current
zhoneGponTrafficProfileGroup
OBJECT-GROUP
Gpon Traffic Profile objects.
1.3.6.1.4.1.5504.9.1.21current
zhoneGponPortStatusGroup
OBJECT-GROUP
Gpon Port Status objects.
1.3.6.1.4.1.5504.9.1.22current
zhoneGponOmciStatusGroup
OBJECT-GROUP
Gpon Omci Status objects.
1.3.6.1.4.1.5504.9.1.24current
zhoneGponOmciOnuRebootGroup
OBJECT-GROUP
Gpon Omci Reboot objects.
1.3.6.1.4.1.5504.9.1.25current
zhoneGponOmciOnuPortAdminGroup
OBJECT-GROUP
Gpon Port Admin objects.
1.3.6.1.4.1.5504.9.1.26current
zhoneGponOmciOnuImageUpgradeGroup
OBJECT-GROUP
Group of ONU Image Upgrade objects
1.3.6.1.4.1.5504.9.1.27current
zhoneGponOltStatusGroup
OBJECT-GROUP
GPON OLT Status Group.
1.3.6.1.4.1.5504.9.1.28current
zhoneGponeOltDbaStatusGroup
OBJECT-GROUP
GPON OLT Dba Status Group.
1.3.6.1.4.1.5504.9.1.29current
zhoneGponCmdGroup
OBJECT-GROUP
GPON Command objects
1.3.6.1.4.1.5504.9.1.31current
zhoneGponOltStatisticsGroup
OBJECT-GROUP
Gpon OLT Statistics objects.
1.3.6.1.4.1.5504.9.1.32current
zhoneGponUpstreamOntStatisticsGroup
OBJECT-GROUP
Gpon Upstream ONT Statistics objects.
1.3.6.1.4.1.5504.9.1.33current
zhoneGponDeprecated
OBJECT-GROUP
Gpon Deprecated objects.
1.3.6.1.4.1.5504.9.1.34deprecated