MIBs Depot

ZHONE-SECHTOR100-MIB

Registered at
1.3.6.1.4.1.5504.2.4.1.1
1.3.6.1.4.1.5504.2.4.1.2
1.3.6.1.4.1.5504.6.19
Last updated
2001-09-28 10:29
Organization
Zhone Technologies, Inc
Revisions
2001-09-28 10:29, 2000-12-27 11:17, 2000-12-21 17:00
Namespace
zhone
Source file
ZHONE-SECHTOR100-MIB
Digest
sha256:ed4b8b7dba04ecc9f67e515e3cf5c652aef263ad6f6238b6e373727747bbbe6e

Description

MIB module for elements specific to Sechtor 100 products.

Contact

Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, MacAddress, TEXTUAL-CONVENTION, TruthValue
Zhonesechtor100, zhoneModules, zhoneShelfIndex, zhoneSlotIndex
Zhone-TCZhoneRowStatus

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
ZHONE-SECHTOR100-MIB
Zhone
Zhone-TC

Objects

NameOIDSyntaxAccessStatus
sechtor100Environment
OBJECT-IDENTITY
All the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex.
1.3.6.1.4.1.5504.2.4.1.1deprecated
s100FanOperationalStatus
OBJECT-TYPE
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.
1.3.6.1.4.1.5504.2.4.1.1.1INTEGER {operational(1), fanFailure(2)}read-onlydeprecated
s100ThermoAUpperThreshold
OBJECT-TYPE
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.2Integer32 (45..80)read-writedeprecated
s100ThermoBUpperThreshold
OBJECT-TYPE
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.3Integer32 (45..80)read-writedeprecated
s10ThermoALowerThreshold
OBJECT-TYPE
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.4Integer32 (-10..5)read-writedeprecated
s100ThermoBLowerThreshold
OBJECT-TYPE
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.5Integer32 (-10..5)read-writedeprecated
s100ThermoATemperature
OBJECT-TYPE
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.6Integer32 (-55..125)read-onlydeprecated
s100ThermoBTemperature
OBJECT-TYPE
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.1.7Integer32 (-55..125)read-onlydeprecated
s100ThermoAOperationalStatus
OBJECT-TYPE
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.
1.3.6.1.4.1.5504.2.4.1.1.8INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)}read-onlydeprecated
s100ThermoBOperationalStatus
OBJECT-TYPE
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.
1.3.6.1.4.1.5504.2.4.1.1.9INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)}read-onlydeprecated
sechtor100Traps
OBJECT-IDENTITY
All Sechtor 100 MIB traps are defined under sechtor100Traps.
1.3.6.1.4.1.5504.2.4.1.2current
sechtor100TrapsPrefix
OBJECT-IDENTITY
Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2.
1.3.6.1.4.1.5504.2.4.1.2.0current
sechtor100ConfigTable
OBJECT-TYPE
This table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile.
1.3.6.1.4.1.5504.2.4.1.3not-accessiblecurrent
sechtor100ConfigEntry
OBJECT-TYPE
An entry in the sechtor100ConfigTable.
1.3.6.1.4.1.5504.2.4.1.3.1not-accessiblecurrent
sechtor100PeerMacAddress
OBJECT-TYPE
This is the Mac address of the peer s100 unit.
1.3.6.1.4.1.5504.2.4.1.3.1.1MacAddressread-writecurrent
sechtor100RedundancyEnable
OBJECT-TYPE
Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.
1.3.6.1.4.1.5504.2.4.1.3.1.2TruthValueread-writecurrent
sechtor100FanOperationalStatus
OBJECT-TYPE
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.
1.3.6.1.4.1.5504.2.4.1.3.1.3INTEGER {operational(1), fanFailure(2)}read-onlycurrent
sechtor100ThermoAUpperThreshold
OBJECT-TYPE
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.4Integer32 (45..80)read-writecurrent
sechtor100ThermoBUpperThreshold
OBJECT-TYPE
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.5Integer32 (45..80)read-writecurrent
sechtor100ThermoALowerThreshold
OBJECT-TYPE
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.6Integer32 (-10..5)read-writecurrent
sechtor100ThermoBLowerThreshold
OBJECT-TYPE
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.7Integer32 (-10..5)read-writecurrent
sechtor100ThermoATemperature
OBJECT-TYPE
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.8Integer32 (-55..125)read-onlycurrent
sechtor100ThermoBTemperature
OBJECT-TYPE
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
1.3.6.1.4.1.5504.2.4.1.3.1.9Integer32 (-55..125)read-onlycurrent
sechtor100ThermoAOperationalStatus
OBJECT-TYPE
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.
1.3.6.1.4.1.5504.2.4.1.3.1.10INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)}read-onlycurrent
sechtor100ThermoBOperationalStatus
OBJECT-TYPE
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.
1.3.6.1.4.1.5504.2.4.1.3.1.11INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)}read-onlycurrent
sechtor100RowStatus
OBJECT-TYPE
Used to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it.
1.3.6.1.4.1.5504.2.4.1.3.1.12ZhoneRowStatusread-createcurrent

Notifications

NameOIDStatus
s100FanStatusChange
NOTIFICATION-TYPE
This trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange.
1.3.6.1.4.1.5504.2.4.1.2.0.1deprecated
s100ThermoStatusChange
NOTIFICATION-TYPE
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange.
1.3.6.1.4.1.5504.2.4.1.2.0.2deprecated
sechtor100FanStatusChange
NOTIFICATION-TYPE
This trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
1.3.6.1.4.1.5504.2.4.1.2.0.3current
sechtor100ThermoStatusChange
NOTIFICATION-TYPE
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
1.3.6.1.4.1.5504.2.4.1.2.0.4current