ZHONE-SECHTOR100-MIB
- Registered at
- 1.3.6.1.4.1.5504.2.4.1.11.3.6.1.4.1.5504.2.4.1.21.3.6.1.4.1.5504.6.19
- Last updated
- 2001-09-28 10:29
- Organization
- Zhone Technologies, Inc
- Revisions
- 2001-09-28 10:29, 2000-12-27 11:17, 2000-12-21 17:00
- Namespace
- zhone
- Source file
ZHONE-SECHTOR100-MIB- Digest
sha256:ed4b8b7dba04ecc9f67e515e3cf5c652aef263ad6f6238b6e373727747bbbe6e
Description
MIB module for elements specific to Sechtor 100 products.
Contact
Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION, TruthValue |
| Zhone | sechtor100, zhoneModules, zhoneShelfIndex, zhoneSlotIndex |
| Zhone-TC | ZhoneRowStatus |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC ZHONE-SECHTOR100-MIB Zhone Zhone-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sechtor100Environment OBJECT-IDENTITY All the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex. | 1.3.6.1.4.1.5504.2.4.1.1 | deprecated | ||
| s100FanOperationalStatus OBJECT-TYPE This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'. | 1.3.6.1.4.1.5504.2.4.1.1.1 | INTEGER {operational(1), fanFailure(2)} | read-only | deprecated |
| s100ThermoAUpperThreshold OBJECT-TYPE This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.2 | Integer32 (45..80) | read-write | deprecated |
| s100ThermoBUpperThreshold OBJECT-TYPE This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.3 | Integer32 (45..80) | read-write | deprecated |
| s10ThermoALowerThreshold OBJECT-TYPE This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.4 | Integer32 (-10..5) | read-write | deprecated |
| s100ThermoBLowerThreshold OBJECT-TYPE This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.5 | Integer32 (-10..5) | read-write | deprecated |
| s100ThermoATemperature OBJECT-TYPE The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.6 | Integer32 (-55..125) | read-only | deprecated |
| s100ThermoBTemperature OBJECT-TYPE The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.1.7 | Integer32 (-55..125) | read-only | deprecated |
| s100ThermoAOperationalStatus OBJECT-TYPE The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold. | 1.3.6.1.4.1.5504.2.4.1.1.8 | INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)} | read-only | deprecated |
| s100ThermoBOperationalStatus OBJECT-TYPE The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold. | 1.3.6.1.4.1.5504.2.4.1.1.9 | INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)} | read-only | deprecated |
| sechtor100Traps OBJECT-IDENTITY All Sechtor 100 MIB traps are defined under sechtor100Traps. | 1.3.6.1.4.1.5504.2.4.1.2 | current | ||
| sechtor100TrapsPrefix OBJECT-IDENTITY Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2. | 1.3.6.1.4.1.5504.2.4.1.2.0 | current | ||
| sechtor100ConfigTable OBJECT-TYPE This table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile. | 1.3.6.1.4.1.5504.2.4.1.3 | not-accessible | current | |
| sechtor100ConfigEntry OBJECT-TYPE An entry in the sechtor100ConfigTable. | 1.3.6.1.4.1.5504.2.4.1.3.1 | not-accessible | current | |
| sechtor100PeerMacAddress OBJECT-TYPE This is the Mac address of the peer s100 unit. | 1.3.6.1.4.1.5504.2.4.1.3.1.1 | MacAddress | read-write | current |
| sechtor100RedundancyEnable OBJECT-TYPE Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable. | 1.3.6.1.4.1.5504.2.4.1.3.1.2 | TruthValue | read-write | current |
| sechtor100FanOperationalStatus OBJECT-TYPE This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'. | 1.3.6.1.4.1.5504.2.4.1.3.1.3 | INTEGER {operational(1), fanFailure(2)} | read-only | current |
| sechtor100ThermoAUpperThreshold OBJECT-TYPE This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.4 | Integer32 (45..80) | read-write | current |
| sechtor100ThermoBUpperThreshold OBJECT-TYPE This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.5 | Integer32 (45..80) | read-write | current |
| sechtor100ThermoALowerThreshold OBJECT-TYPE This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.6 | Integer32 (-10..5) | read-write | current |
| sechtor100ThermoBLowerThreshold OBJECT-TYPE This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.7 | Integer32 (-10..5) | read-write | current |
| sechtor100ThermoATemperature OBJECT-TYPE The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.8 | Integer32 (-55..125) | read-only | current |
| sechtor100ThermoBTemperature OBJECT-TYPE The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius. | 1.3.6.1.4.1.5504.2.4.1.3.1.9 | Integer32 (-55..125) | read-only | current |
| sechtor100ThermoAOperationalStatus OBJECT-TYPE The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold. | 1.3.6.1.4.1.5504.2.4.1.3.1.10 | INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)} | read-only | current |
| sechtor100ThermoBOperationalStatus OBJECT-TYPE The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold. | 1.3.6.1.4.1.5504.2.4.1.3.1.11 | INTEGER {withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)} | read-only | current |
| sechtor100RowStatus OBJECT-TYPE Used to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it. | 1.3.6.1.4.1.5504.2.4.1.3.1.12 | ZhoneRowStatus | read-create | current |
Notifications
| Name | OID | Status |
|---|---|---|
| s100FanStatusChange NOTIFICATION-TYPE This trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange. | 1.3.6.1.4.1.5504.2.4.1.2.0.1 | deprecated |
| s100ThermoStatusChange NOTIFICATION-TYPE This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange. | 1.3.6.1.4.1.5504.2.4.1.2.0.2 | deprecated |
| sechtor100FanStatusChange NOTIFICATION-TYPE This trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects. | 1.3.6.1.4.1.5504.2.4.1.2.0.3 | current |
| sechtor100ThermoStatusChange NOTIFICATION-TYPE This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects. | 1.3.6.1.4.1.5504.2.4.1.2.0.4 | current |