MIBs Depot

ZHONE-GEN-WTN-MONITOR-MIB

Registered at
1.3.6.1.4.1.5504.3.9.1
1.3.6.1.4.1.5504.3.9.2
1.3.6.1.4.1.5504.6.102
Last updated
1900-09-28 12:16
Organization
Zhone Technologies, Inc.
Revisions
1901-05-25 21:36
Namespace
zhone
Source file
ZHONE-GEN-WTN-MONITOR-MIB
Digest
sha256:9d4f542a1b5d38d25fedcf9909d4cf04b0965f21340189684340d6f149f9690a

Description

Module for wireless transport node (ZWT) variables which report general system status.

Contact

Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
ZhonezhoneGenWtn, zhoneModules

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
ZHONE-GEN-WTN-MONITOR-MIB
Zhone

Objects

NameOIDSyntaxAccessStatus
wtnMonitor
OBJECT-IDENTITY
Collection of monitored elements for each wireless transport node.
1.3.6.1.4.1.5504.3.9.1current
wtnLedStatus
OBJECT-TYPE
Reflects current state of LEDs of indoor unit. A bit value of 1 indicates the LED is ON. A bit value of 0 indicates the LED of OFF. Meaning of LEDs: =========================================== diag - Upon power up the LED is turned on. If the unit successfully passes diagnostics, the LED is turned off. When operational, the LED is turned on when diagnostics are performed or when the system detects an alarm. operational - Upon power up the LED is off. When the system is operating it is turned on. The actual LED is blinked when the ZMS link is down or during software download. lineInterface - This LED is turned on when there are no wire-line alarms. For SkyZhone45 - this refers to the DS3 line. For SkyZhone155 - this refers to the fiber. For SkyZhone8e - this refers to the set of T1/E1 lines. radio - This LED is turned on when there are no radio receive alarms. local- This LED is turned on when there are not alarms present on the Near End indoor or outdoor units. remote - This LED is turned on when there are not alarms present on the Far End indoor or outdoor units.
1.3.6.1.4.1.5504.3.9.1.1Bits {diag(0), operational(1), lineInterface(2), radio(3), local(4), remote(5)}read-onlycurrent
wtnAlarmStatus
OBJECT-TYPE
Alarm Contact Status. minorAlarm(0) - when active, a minor alarm condition is present criticalAlarm(1) - when active, a critical alarm condition is present. On power up all alarms contacts are open/inactive (0).
1.3.6.1.4.1.5504.3.9.1.2Bits {minorAlarm(0), criticalAlarm(1)}read-onlycurrent
radioLinkConfiguration
OBJECT-IDENTITY
Description.
1.3.6.1.4.1.5504.3.9.2current
wtnLinkName
OBJECT-TYPE
Textual description which identifies link. A link is comprised of this and another SkyZhone node at the far end.
1.3.6.1.4.1.5504.3.9.2.1SnmpAdminStringread-writecurrent